Schneider Electric SmartDim puck Uni - Device User Guide

Add to My manuals
26 Pages

advertisement

Schneider Electric SmartDim puck Uni - Device User Guide | Manualzz

SmartDim puck Uni

Device User Guide

Commissioning instructions for the ELKO Smart system, devices and app.

02/2023

www.elko.no

Legal Information

The ELKO brand and any trademarks of ELKO AS and its subsidiaries referred to in this guide are the property of ELKO AS or its subsidiaries. All other brands may be trademarks of their respective owners.

This guide and its content are protected under applicable copyright laws and furnished for informational use only. No part of this guide may be reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise), for any purpose, without the prior written permission of

ELKO.

ELKO does not grant any right or license for commercial use of the guide or its content, except for a non-exclusive and personal license to consult it on an "as is" basis. ELKO products and equipment should be installed, operated, serviced, and maintained only by qualified personnel.

As standards, specifications, and designs change from time to time, information contained in this guide may be subject to change without notice.

To the extent permitted by applicable law, no responsibility or liability is assumed by

ELKO and its subsidiaries for any errors or omissions in the informational content of this material or consequences arising out of or resulting from the use of the information contained herein.

Table of Contents

Safety information

.......................................................................................4

SmartDim puck Uni

.....................................................................................5

For your safety ...........................................................................................5

About the device.........................................................................................6

Installing the device ....................................................................................6

Testing the device.......................................................................................6

Pairing the device with Smart Hub................................................................7

Pairing device manually.........................................................................7

Pairing device with auto scan.................................................................8

Configuring the device ................................................................................9

Changing the device icon ......................................................................9

Renaming the device ..........................................................................10

Changing the device location ...............................................................10

Setting RL-LED mode ......................................................................... 11

Setting brightness level ....................................................................... 11

Toggle mode setting ............................................................................12

Removing the device ................................................................................12

Resetting the device .................................................................................13

Using the device .......................................................................................14

Manual operation ................................................................................14

Adjusting the brightness level using app ...............................................14

Setting up a schedule ..........................................................................15

Creating a moment .............................................................................15

Creating an automation .......................................................................18

LED indication ..........................................................................................22

Troubleshooting .......................................................................................22

Technical data ..........................................................................................23

DUG_SmartDim Puck_ELKO-00 3

4

Safety information

Safety information

Important information

Read these instructions carefully and look at the equipment to become familiar with the device before trying to install, operate, service, or maintain it. The following special messages may appear throughout this manual or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure.

The addition of either symbol to a “Danger” or “Warning” safety label indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed.

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that accompany this symbol to avoid possible injury or death.

DANGER

DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.

Failure to follow these instructions will result in death or serious injury.

WARNING

WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION

CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

NOTICE

NOTICE is used to address practices not related to physical injury.

DUG_SmartDim Puck_ELKO-00

SmartDim puck Uni

SmartDim puck Uni

EKO07090

For your safety

DANGER

HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH

Safe electrical installation must be carried out only by skilled professionals.

Skilled professionals must prove profound knowledge in the following areas:

• Connecting to installation networks.

• Connecting several electrical devices.

• Laying electric cables.

• Safety standards, local wiring rules and regulations.

Failure to follow these instructions will result in death or serious injury.

DANGER

HAZARD OF ELECTRIC SHOCK

• Make sure that the terminal connection area does not come in contact with the metallic parts of any device installed in the same location.

• Do not short the outputs to neutral.

Failure to follow these instructions will result in death or serious injury.

CAUTION

EQUIPMENT DAMAGE

• Always operate the product in compliance with the specified technical data.

• Never connect any mixed inductive/capacitive loads.

• Connect only dimmable loads.

• Do not connect the dimmer output to the socket outlet.

Failure to follow these instructions can result in injury or equipment damage.

DUG_SmartDim Puck_ELKO-00 5

6

SmartDim puck Uni

About the device

The SmartDim Puck Uni (hereinafter referred to as Puck / Micro Module Dimmer) combines the advantages of smart dimmer functionality with ordinary mechanical push-button switches. It transforms a conventional switch into a connected device which can be controlled from the switch or through the ELKO Smart app. It can switch and dim the ohmic, inductive, or capacitive loads and it is also compatible with dimmable LEDs.

NOTE: Do not control any devices that depend on a permanent power supply.

Additional features:

• Remote control with maximum of 10 single mechanical push-buttons.

• Setting the LED operating mode manually (RL LED mode).

• Electronic overload protection, overheating protection, and short-circuit protection.

• Setting the dimming range: minimum and maximum brightness.

• Setting a time schedule.

Installing the device

Refer to the installation instruction supplied with this product.

See SmartDim puck Uni .

Testing the device

Before using the Puck, manually test the Puck and make sure that it works when connected to the lighting devices.

WARNING

HAZARD OF ELECTRIC SHOCK

• Observe the regulations for working on live parts.

• Only actuate the device buttons using insulated auxiliary equipment that meets the requirements of EN 60900.

Failure to follow these instructions can result in death, serious injury, or equipment damage.

• Short press the test button once, the connected lighting device turns On/Off.

• Press and hold the test button to adjust the dimming level of the connected lighting device.

L 1

< 1 s

> 1 s

DUG_SmartDim Puck_ELKO-00

SmartDim puck Uni

Pairing the device with Smart Hub

Using the ELKO Smart app, first pair your device with the ELKO SmartHub to access and control the device. You can either add the device manually or do an auto-scan to pair it.

Pairing device manually

To pair the device manually:

1. On Home page, tap + .

2. Tap and select ELKO SmartHUB on the slide-up menu and tap Done .

3. Select any one of the options to add device (A):

– Add Device with Install Code

– Add Device without Install Code

Add Device

Install Code is Recommended

Add Device without Install Code

A

TIP: It is recommended to add the device with install code.

4. To pair the device with install code, tap Add Device with Install Code to display the slide-up menu. Select any one of the options (B):

– Scan Install Code : you can scan the device for the install code.

– Enter Install Code Manually : you can manually enter the install code from the device.

TIP: you can find the install code on the rear side of the device.

After scanning or entering the install code, proceed to Step 7 .

DUG_SmartDim Puck_ELKO-00

Add Device without Install Code B

5. To pair the device without install code, tap Add Device without Install Code .

7

SmartDim puck Uni

6. Select any one of the options to add the device:

– Short press the S/R (setup/reset) button 3 times (<0,5 s) on the Puck with a screwdriver.

– Short press the push button 3 times.

3 × < 0,5 s

L 1

3 × < 0,5 s

The LED blinks orange.

NOTE: If the puck is located behind the push button, the status LED is not visible.

7. In the app, select Confirm LED is flashing orange and tap Start

Configuration (C).

Cancel

How to Pair Device

Short-press S/R button 3 times.

1 2 x 3

C

After a few seconds, a solid green LED indicates that the device is successfully paired to the ELKO SmartHUB .

8

8. Tap Done when the pairing is successful..

Pairing device with auto scan

Pairing the device with auto scan automatically discovers the device when the corresponding device is powered on.

1. On the Home page, tap + .

2. Tap Auto scan > Confirm .

3. Enable permissions to Access location and Wi-Fi for scanning device and tap Start scanning .

NOTE: If you have multiple hubs, do Step 4 or proceed to Step 5.

4. Tap Select hub and select the ELKO SmartHub from the slide-up menu.

DUG_SmartDim Puck_ELKO-00

SmartDim puck Uni

5. Short press the setup/reset button 3 times (< 0,5 s) and wait for a few seconds until the device search is complete.

The LED blinks orange.

TIP: If you want to pair multiple devices at once, perform step 5 on each device and wait for a few seconds for them to be detected.

6. Tap Next (A) and select Micromodule Dimmer .

Auto Scan

Available devices found

Micro Module

Dimmer

Next

A

7. Once the device is added successfully, tap Done .

Configuring the device

Changing the device icon

You can change the device icon using the ELKO Smart app.

1. On the Home page, select the device for which you wish to change the icon.

.

2. At the top-right corner of the screen, tap

3. Tap edit next to the device name.

4. Tap Icon to view the menu.

DUG_SmartDim Puck_ELKO-00 9

SmartDim puck Uni

5. In the slide-up menu, select any one of the following (A) to change the device icon:

– Take photo - allows you to click a photo from the mobile camera.

– Select from Icon Library - allows you to select an icon from the app library.

– Select from Album - allows you to select a photo from the mobile gallery.

Renaming the device

You can rename the device using the ELKO Smart app.

1. On the Home page, select the device for which you wish to rename.

2. At the top-right corner of the screen, tap .

3. Tap edit next to the device name.

4. Tap Name , enter the new name (A) and then tap Save .

Rename

Save

A

Changing the device location

You can change the device location using the ELKO Smart app.

1. On the Home page, select the device for which you wish to change the location.

2. At the top-right corner of the screen, tap .

10 DUG_SmartDim Puck_ELKO-00

SmartDim puck Uni

3. Tap edit next to the device name.

4. Tap Location .

5. Select the desired location from the list (A) and then tap Save .

Device location

Living Room

Master Bedroom

Save

A

Dining Room

Study Room

Kids Room

Setting RL-LED mode

You can change the dimming mode in the app if you have problems with light flickering. By changing the dimming mode, the dimming quality is also improved.

To set the RL-LED mode:

1. On the Home page, Tap All devices > Micromodule Dimmer

2. Tap Settings .

3. Tap Dimming Mode and Select Leading Edge (RL-LED) (A) from the slideup menu.

NOTE:

• Refer to

Technical Data, page 23

for more information.

• Manual operation (Optional): Press the TEST button 14 times.

◦ If the status LED blinks 3 times in green, RL-LED mode is enabled.

◦ If the status LED blinks once in green, Auto mode is enabled.

Auto

Cancel

A

Setting brightness level

If the dimmer is connected to an LED, the minimum and maximum brightness should be set to avoid flickering and switching off the LED.

To set the minimum and maximum brightness level:

DUG_SmartDim Puck_ELKO-00 11

SmartDim puck Uni

1. On the Home page, Tap All devices > Micromodule Dimmer .

2. Tap Settings .

3. Tap Dimming Range then drag the sliding bar to increase or decrease the

Minimum Brightness and Maximum Brightness (A).

4. Tap Close (B).

Close

A

B

Toggle mode setting

You can toggle between the last used brightness level or with 100% brightness level when the dimmer is turned on.

To toggle between the brightness level:

1. On the Home page, tap All devices > Micromodule Dimmer .

2. Tap Settings .

3. Tap Toggle Mode Setting and select either one of the function for default action.

– 100% (A) : to set the brightness level to 100% by default when ever the device is turned on.

– Last Level (B) : to set the previously used brightness level by default when ever the device is turned on.

A

B

100%

Cancel

Removing the device

Using the ELKO Smart app, you can remove a device from the device list.

To remove the device:

12 DUG_SmartDim Puck_ELKO-00

SmartDim puck Uni

1. On the Home page, tap All devices > Micromodule Dimmer .

2. Tap to display more details.

3. Tap Remove and Factory Reset Device (A).

More

Micro Module Dimmer

Device Information

Moment and Automation

Others

FAQ & Feedback

Add to Home Screen

No updates available.

Remove and Factory Reset Device

A

TIP: Alternatively, you can long tap on the Micromodule Dimmer on the

Home page to remove the device.

NOTE:

• Removing the device will reset the Puck. After reset the LED turns orange indicating that the Puck is ready to pair with another network.

• If there is a problem while pairing or resetting the Puck, refer to

Resetting the device manually, page 13 .

Resetting the device

You can reset the device to factory default manually.

1. Short press the Setup/Reset button 3 times (< 0.5 s) and then long press the

Setup/Reset button once (>10 s).

or

Short press the push button 3 times and then long press the push-button once for 10 s.

L 1

3 × < 0,5 s +

1 × 10 s

3 × < 0,5 s +

1 × 10 s

2. After 10 s, LED starts blinking red, then release the push-button.

NOTE: All configuration data, user data, and network data are deleted.

After which

• No connectivity to other devices or rooms.

• Memory function is active.

• Automatic load detection is active, RC mode is set.

• Dimmer settings will reset to default.

The LED stops blinking upon successful reset of the device.

The Puck restarts and blinks green for a few seconds.

DUG_SmartDim Puck_ELKO-00 13

SmartDim puck Uni

Using the device

Manual operation

When the puck is connected to a mechanical push button, the connected lighting devices can be controlled manually.

• Short press the push button to turn on/off the light.

• Press and hold the push button to adjust the dimming level of the light.

< 1 s

> 1 s

Adjusting the brightness level using app

Using the ELKO Smart app, you can increase/decrease the brightness level remotely.

To increase/decrease the brightness level:

1. On the Home page, tap All devices.

2. In Micromodule Dimmer tap the power button (A) to turn on/off the device.

Home

My Home

Welcome Home

Set your home location for more information.

Away

• • •

A

All Devices

Micro Module Dimmer

Home Automations

3. Tap for slide-up menu.

4. In the slide-up menu, drag the sliding bar (B) to increase/decrease the brightness.

Home Away

75%

Home Automations

B

14 DUG_SmartDim Puck_ELKO-00

SmartDim puck Uni

5. Alternatively, you can navigate to device menu and tap on (C) to turn on/off the device. When the device is turned on, drag the sliding bar (D) up/down to increase/decrease the brightness.

Micro Module Dimmer

C

D

ON

75

%

Schedule

Setting up a schedule

The device can be fully controlled by schedule. Once the schedule is set, the device operates at a given time.

1. On the Home page, Tap All devices > Micromodule Dimmer .

2. Tap Schedule > Add Schedule to add a schedule.

3. In Add Schedule menu, set the time (A).

NOTE: The Schedule works according to the time zone where the device is located.

4. Tap Repeat (B) to select the days you want to set the schedule.

5. Tap Note (C), enter the note and tap Confirm .

6. Tap the toggle switch (D) to turn on the Notification for the schedule. The app will send a notification that the scheduled task is executed at the time of schedule.

7. Adjust the Brightness settings (E) through sliding bar.

Cancel Add Schedule

06

07

08

09

10

11

12

13

14

09

10

11

12

13

05

06

07

08

B

C

Repeat

Note

Save

Once

A

D

Micro Module Dimmer

50% 100%

E device is located.

8. Tap Save

Creating a moment

Moment allows you to group multiple actions that are usually done together. Using the ELKO Smart app, you can create moments based on your needs.

DUG_SmartDim Puck_ELKO-00 15

SmartDim puck Uni

1. On the Home page, tap .

2. Go to Moment > + to create a moment.

3. Tap Edit name (A), enter the name of the moment and tap Save .

TIP : You can choose the cover image that represents your moment by tapping .

Edit name

A

Edit name

Add Task

Save

4. In the Action section, tap Add task (B) to open the slide-up menu.

5. In the Add task menu, you can do either or all of the following actions (C):

– Run the device : select the devices that you want in a moment.

– Select Automation : select the automation that you want to enable or disable.

– Delay : set the delay time.

NOTE : You can add one or more actions using .

16 DUG_SmartDim Puck_ELKO-00

SmartDim puck Uni

6. Tap Run the device > Micromodule Dimmer to select either or all the functions to add in the moment:

– Dimmer (D): turn on/off the device.

– Brightness (E): set the percentage of brightness required.

D

E

Dimmer

Select function Next

On

50%

7. Tap Next and once the actions are set, tap Save .

Cancel Moment settings Save

My Moment

Action

Micro Module Dimmer

Micro Module Dimmer

Dimmer:On

Show on Home Page

Editing a moment

To edit a moment:

1. On the Moment tab, locate the moment you want to edit and tap .

2. On the Edit page, you can tap each item (such as dimmer, shutter, delay, temperature, etc.) to change the settings.

TIP:

• You can add one or more actions using .

• To delete an existing action, slide the each item towards left and tap

Delete .

Deleting a moment

To delete a moment:

1. On the Moment tab, locate the moment that you want to delete and then tap

.

2. Tap Delete and than tap Ok .

NOTE: After deleting a moment, the device action can no longer be triggered.

DUG_SmartDim Puck_ELKO-00 17

SmartDim puck Uni

Creating an automation

An automation allows you to group multiple actions that are usually done together, triggered automatically or at scheduled times. By using the ELKO Smart app, you can create automations based on your needs.

1. On the Home page, tap the .

2. Go to Automation > + to create an automation.

3. Tap Edit name (A), enter the name of the automation and tap Save .

TIP : You can choose the cover image that represents your automation by tapping .

My Automation

A

Edit name

Add Condition

4. Tap Any condition is met to select any one of the condition type (B):

– All conditions are met : the automation is triggered when all the conditions are met.

– Any condition is met : the automation is triggered when at least one condition is met.

18

5. Tap Add Condition to open the slide-up menu.

DUG_SmartDim Puck_ELKO-00

SmartDim puck Uni

6. In the Add Condition menu, you can do either or all of the following options

(C):

– When weather changes : select the various weather settings.

– Schedule : set the time and day.

– When device status changes : select the device and it’s function.

NOTE: You can add one or more conditions using .

My Automation

Add Condition

C

7. Tap When device status changes > Micro Module Dimmer and select either or both the functions:

– Dimmer : turn the Dimmer on/off (D).

– Brightness : adjust the brightness level (E).

Select function

Next

D

E

8. Tap Add task to open the slide-up menu.

DUG_SmartDim Puck_ELKO-00 19

SmartDim puck Uni

9. In the Add task menu, you can do either or all of the following options (F):

– Run the device : select the devices that you want to trigger.

– Moment or Automation : select the moment which you want to trigger or select the automation that you want to enable or disable.

– Send notification : turn on notification for the automation.

– Delay : set the delay time.

NOTE : You can add one or more actions using .

My Automation

Action

Add task

(Added 0/80)

Add Task

All-Day

F

10. Tap on Effective period to set the time range for the automation. You can select any one of the following (G):

– All-day - 24 hours

– Daytime - From sunrise to sunset

– Night - From sunset to sunrise

– Custom - User defined time period

Next

24 hours

From sunrise to sunset

G From sunset to sunrise

Custom

City

11. Once all the actions and conditions are set, tap Save .

Once the automation is saved, it is visible on the Automation tab. You can tap the toggle switch on the automation to enable it.

Example of an automation

This demonstration shows you how to create an automation to turn on the dimmer at the scheduled time.

1. Go to Automation > + to create an automation.

2. Tap Edit name , enter the name of the automation and tap Save .

TIP : You can choose the cover image that best represents your automation by tapping .

20 DUG_SmartDim Puck_ELKO-00

SmartDim puck Uni

3. Tap Add Condition > Schedule .

• Tap Repeat (A), select the days you want to set the schedule and tap

Save .

• Set the time (B) at which the automation must start and tap Next .

Schedule Next

A

Repeat

04 29

05 30

06 31

B

4. Tap Add task > Run the device > Micromodule Dimmer .

5. Tap Dimmer (C) and in the slide-up menu, select On and tap Save .

6. Tap Brightness (D) and update the required brightness level and tap Save .

C

D

Dimmer

Select function Next

On

50%

DUG_SmartDim Puck_ELKO-00

7. Tap Next .

8. In the Automation Settings page, tap Save .

Cancel Automation settings Save

My Moment

Any condition is met

Schedule:05:30

Action

Micro Module Dimmer

Micro Module Dimmer

Dimmer:On

All-Day

Once the automation is saved, it is visible on the Automation tab. You can tap the toggle switch on the automation to enable it.

21

SmartDim puck Uni

Editing an automation

To edit an automation:

1. On the Automation tab, locate the automation you want to edit and tap .

2. On the Edit page, you can tap each item (such as dimmer, shutter, delay, temperature, etc.) to change the settings.

TIP:

• You can add one or more actions using .

• To delete an existing condition or action, slide each item towards left and tap Delete .

Deleting an automation

To delete an automation:

1. On the Automation tab, locate the automation that you want to delete and then tap .

2. Tap Delete and tap Ok .

NOTE: After deleting an automation, the device action can no longer be triggered.

LED indication

Pairing the device

User Action

Short press the setup/reset button or push button 3 times.

LED Indication

LED blinks orange once per second.

Status

Pairing mode is active for 30 seconds. When pairing is completed, LED glows green for a few seconds before turning Off.

Resetting the device

User Action

Short press the setup/reset button or push button 3 times and hold it down once for > 10 s.

LED Indication

LED blinks red once per second.

Status

The device is in reset mode. The device then restarts and LED turns orange indicating that the device is ready for pairing.

Troubleshooting

Symptom

Dimming up not possible.

Switching on not possible.

Flickering at minimum brightness.

22

Solution

• Reduce/increase load.

• Allow the Puck to cool in case of overheating.

• Change the load (if the load is incompatible with the Puck).

• Allow the Puck to cool in case of overheating.

• Reduce load.

• Change load.

• Check wiring between the push button and the Puck.

• Increase minimum brightness (if flickering still persists, install a 31LCDA load correction device).

DUG_SmartDim Puck_ELKO-00

SmartDim puck Uni

Symptom

Flickering

Only slight dimming capability

The device is not ready to pair after the device is removed from the app.

Solution

• Change the load (if the minimum brightness is insufficient).

• Set RL LED mode (it is advised to use 10 % of nominal load to avoid overheating of the puck).

• Change load.

• Set RL LED mode (it is advised to use 10 % of nominal load to avoid overheating of the puck).

• Change dimming range.

• Set RL LED mode (it is advised to use 10 % of nominal load to avoid overheating of the puck).

• Change the load (if the load is incompatible with the Puck).

Reset to factory default settings, refer to Resetting the device manually .

Technical data

Nominal power rating for load type

LED

Incandescent lamp

Iron core transformer

Halogen lamp

5 – 100 VA RC

5 – 20 VA RL

14 – 200 W

R

14 – 150 VA

L

14 – 150 W

R

Electronic step-down converter

C

Nominal voltage

Dimming channel

Standby

Operating Temperature

Neutral conductor

Connecting terminals

Extension connection

Length of all cable sections

Fuse protection

Operating frequency

Max. radio-frequency power transmitted

IP rating

Product dimensions (H x W x D)

Communication protocol

14 – 200 VA

C

AC 220-240 V, 50/60 Hz

1

Max. 0.4 W

0 ºC to 35 ºC

Not required

Max. 2 x 2.5 mm 2 , solid or stranded types

Max. 10 mechanical push buttons

Max. 50 m for 3-wire NYM cable

16 A circuit breaker

2405 - 2480 MHz

<10 mW

IP20

43 x 43 x 22 mm

Zigbee 3.0 certified

DUG_SmartDim Puck_ELKO-00 23

Trademarks

This guide makes reference to system and brand names that are trademarks of their relevant owners.

• Zigbee ® is a registered trademark of the Connectivity Standards Alliance.

• Apple ® and App Store ® are brand names or registered trademarks of Apple Inc.

• Google Play™ Store and Android™ are brand names or registered trademarks of Google Inc.

• Wi-Fi ® is a registered trademark of Wi-Fi Alliance ® .

Other brands and registered trademarks are the property of their respective owners.

ELKO AS

Sandstuveien 68, 0680 Oslo

Pb 6598 Etterstad, 0607 Oslo

Norway

+47 67 79 39 00 [email protected]

www.elko.no

As standards, specifications, and design change from time to time, please ask for confirmation of the information given in this publication.

© 2023 – ELKO AS . All rights reserved.

DUG_SmartDim Puck_ELKO-00

advertisement

Related manuals