Installation Instructions Original Instructions FLEX I/O 2-input Frequency Modules Catalog Numbers 1794-IJ2, 1794-IJ2XT Topic Summary of Changes Environment and Enclosure Prevent Electrostatic Discharge European Hazardous Location Approval North American Hazardous Location Approval Install Your Frequency Input Module Connecting Wiring for the 1794-TB3G and 1794-TB3GS Terminal Base Unit Resolution and Accuracy Interpret Status Indicators Diagnostics Specifications Page 1 3 3 4 4 5 5 7 8 9 10 Summary of Changes This publication contains the following new or updated information. This list includes substantive updates only and is not intended to reflect all changes. Topic Updated template Removed discontinued Catalog Number 1794-IJ2K Updated Environment and Enclosure Updated European and IEC Hazardous Location Approvals Updated Special Conditions for Safe Use Updated temp codes Updated environmental specifications Updated certifications Page throughout throughout 3 4 4 11 11-12 12 FLEX I/O 2-input Frequency Modules Installation Instructions ATTENTION: Read this document and the documents listed in the Additional Resources section about installation, configuration and operation of this equipment before you install, configure, operate or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards. Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice. If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. 岤䠑㖈㸝鄳ծꂁ縨ծ乼⡲ㄤ絶䫡劥❡ㅷ霼ꢓ靀劥俒咓⟄⿺ Ⱖ➭餴彂 鿈ⴔⴀ涸剣Ⱒ霃㢊㸝鄳ծꂁ縨ㄤ乼⡲涸湱䎾俒咓կꤑ✫䨾剣鷓欽錞薴ծ岁䖒ㄤ叻ⲥ 涸湱Ⱒ銳宠⛓㢪欽䨪鵮䗳곢擿䜪㸝鄳ㄤ䱹絁霹僈կ 㸝鄳ծ靈侮ծ䫏鵘ծ⢪欽ծ絆鄳ծ䬒⽸ㄤ絶䫡瘝ぐ고乼⡲䗳곢歋絑鵂鷓䔲雲絅涸⚁⚌➃プ䭽撑鷓欽涸乼⡲錞薴㹊倶կ 㥵卓劢䭽撑ⵖ鸣㉁䭷㹁涸倰䒭⢪欽霪霃㢊ⴭ〳腊⠔䰀㹲霃㢊䲿⣘涸⥂䫡կ ATENCIÓN: Antes de instalar, configurar, poner en funcionamiento o realizar el mantenimiento de este producto, lea este documento y los documentos listados en la sección Recursos adicionales acerca de la instalación, configuración y operación de este equipo. Los usuarios deben familiarizarse con las instrucciones de instalación y cableado y con los requisitos de todos los códigos, leyes y estándares vigentes. El personal debidamente capacitado debe realizar las actividades relacionadas a la instalación, ajustes, puesta en servicio, uso, ensamblaje, desensamblaje y mantenimiento de conformidad con el código de práctica aplicable. Si este equipo se usa de una manera no especificada por el fabricante, la protección provista por el equipo puede resultar afectada. ATENÇÃO: Leia este e os demais documentos sobre instalação, configuração e operação do equipamento que estão na seção Recursos adicionais antes de instalar, configurar, operar ou manter este produto. Os usuários devem se familiarizar com as instruções de instalação e fiação além das especificações para todos os códigos, leis e normas aplicáveis. É necessário que as atividades, incluindo instalação, ajustes, colocação em serviço, utilização, montagem, desmontagem e manutenção sejam realizadas por pessoal qualificado e especializado, de acordo com o código de prática aplicável. Caso este equipamento seja utilizado de maneira não estabelecida pelo fabricante, a proteção fornecida pelo equipamento pode ficar prejudicada. ВНИМАНИЕ: Перед тем как устанавливать, настраивать, эксплуатировать или обслуживать данное оборудование, прочитайте этот документ и документы, перечисленные в разделе «Дополнительные ресурсы». В этих документах изложены сведения об установке, настройке и эксплуатации данного оборудования. Пользователи обязаны ознакомиться с инструкциями по установке и прокладке соединений, а также с требованиями всех применимых норм, законов и стандартов. Все действия, включая установку, наладку, ввод в эксплуатацию, использование, сборку, разборку и техническое обслуживание, должны выполняться обученным персоналом в соответствии с применимыми нормами и правилами. Если оборудование используется не предусмотренным производителем образом, защита оборудования может быть нарушена. : ACHTUNG: Lesen Sie dieses Dokument und die im Abschnitt „Weitere Informationen“aufgeführten Dokumente, die Informationen zu Installation, Konfiguration und Bedienung dieses Produkts enthalten, bevor Sie dieses Produkt installieren, konfigurieren, bedienen oder warten. Anwender müssen sich neben den Bestimmungen aller anwendbaren Vorschriften, Gesetze und Normen zusätzlich mit den Installations- und Verdrahtungsanweisungen vertraut machen. Arbeiten im Rahmen der Installation, Anpassung, Inbetriebnahme, Verwendung, Montage, Demontage oder Instandhaltung dürfen nur durch ausreichend geschulte Mitarbeiter und in Übereinstimmung mit den anwendbaren Ausführungsvorschriften vorgenommen werden. Wenn das Gerät in einer Weise verwendet wird, die vom Hersteller nicht vorgesehen ist, kann die Schutzfunktion beeinträchtigt sein. ATTENTION : Lisez ce document et les documents listés dans la section Ressources complémentaires relatifs à l’installation, la configuration et le fonctionnement de cet équipement avant d’installer, configurer, utiliser ou entretenir ce produit. Les utilisateurs doivent se familiariser avec les instructions d’installation et de câblage en plus des exigences relatives aux codes, lois et normes en vigueur. Les activités relatives à l’installation, le réglage, la mise en service, l’utilisation, l’assemblage, le démontage et l’entretien doivent être réalisées par des personnes formées selon le code de pratique en vigueur. Si cet équipement est utilisé d’une façon qui n’a pas été définie par le fabricant, la protection fournie par l’équipement peut être compromise. : , , , . , . , , , , , , . . ATTENZIONE Prima di installare, configurare ed utilizzare il prodotto, o effettuare interventi di manutenzione su di esso, leggere il presente documento ed i documenti elencati nella sezione “Altre risorse”, riguardanti l’installazione, la configurazione ed il funzionamento dell’apparecchiatura. Gli utenti devono leggere e comprendere le istruzioni di installazione e cablaggio, oltre ai requisiti previsti dalle leggi, codici e standard applicabili. Le attività come installazione, regolazioni, utilizzo, assemblaggio, disassemblaggio e manutenzione devono essere svolte da personale adeguatamente addestrato, nel rispetto delle procedure previste. Qualora l’apparecchio venga utilizzato con modalità diverse da quanto previsto dal produttore, la sua funzione di protezione potrebbe venire compromessa. DİKKAT: Bu ürünün kurulumu, yapılandırılması, işletilmesi veya bakımı öncesinde bu dokümanı ve bu ekipmanın kurulumu, yapılandırılması ve işletimi ile ilgili İlave Kaynaklar bölümünde yer listelenmiş dokümanları okuyun. Kullanıcılar yürürlükteki tüm yönetmelikler, yasalar ve standartların gereksinimlerine ek olarak kurulum ve kablolama talimatlarını da öğrenmek zorundadır. Kurulum, ayarlama, hizmete alma, kullanma, parçaları birleştirme, parçaları sökme ve bakım gibi aktiviteler sadece uygun eğitimleri almış kişiler tarafından yürürlükteki uygulama yönetmeliklerine uygun şekilde yapılabilir. Bu ekipman üretici tarafından belirlenmiş amacın dışında kullanılırsa, ekipman tarafından sağlanan koruma bozulabilir. 岤䠑✲갪㖈㸞酤鏤㹁乽⡲䧴笞隌劥欴ㅷ锞⯓ꠗ隡姽俒⟝⟃⿻倴 չⰦ➮须彂պ畎眏⚥剤ꡠ㸞酤鏤㹁莅乽⡲姽鏤⪔涸俒⟝⢪欽罏䗳갭擿䜫㸞酤ㄤꂂ箁䭸 爚⚛痘ざ䨾剤岁鋊岁䖒ㄤ垦彋銴宠 ⺫䭍㸞酤锅侮❜➰⢪欽⢪欽穉酤䬓⽹ㄤ笞隌瘞⹛⡲鿪䗳갭❜歋䊺竤麕黠殹鎯箻涸➃㆞鹎遤⟃痘ざ黠欽涸㻜⡲岁鋊 㥶卓㼟鏤⪔欽倴ꬌ醢鸤㉂䭸㹁涸欽鸁儘〳腋剚鸤䧭鏤⪔䨾䲿⣘涸⥃隌⸆腋「䴦 POZOR: Než začnete instalovat, konfigurovat či provozovat tento výrobek nebo provádět jeho údržbu, přečtěte si tento dokument a dokumenty uvedené v části Dodatečné zdroje ohledně instalace, konfigurace a provozu tohoto zařízení. Uživatelé se musejí vedle požadavků všech relevantních vyhlášek, zákonů a norem nutně seznámit také s pokyny pro instalaci a elektrické zapojení. Činnosti zahrnující instalaci, nastavení, uvedení do provozu, užívání, montáž, demontáž a údržbu musí vykonávat vhodně proškolený personál v souladu s příslušnými prováděcími předpisy. Pokud se toto zařízení používá způsobem neodpovídajícím specifikaci výrobce, může být narušena ochrana, kterou toto zařízení poskytuje. UWAGA: Przed instalacją, konfiguracją, użytkowaniem lub konserwacją tego produktu należy przeczytać niniejszy dokument oraz wszystkie dokumenty wymienione w sekcji Dodatkowe źródła omawiające instalację, konfigurację i procedury użytkowania tego urządzenia. Użytkownicy mają obowiązek zapoznać się z instrukcjami dotyczącymi instalacji oraz oprzewodowania, jak również z obowiązującymi kodeksami, prawem i normami. Działania obejmujące instalację, regulację, przekazanie do użytkowania, użytkowanie, montaż, demontaż oraz konserwację muszą być wykonywane przez odpowiednio przeszkolony personel zgodnie z obowiązującym kodeksem postępowania. Jeśli urządzenie jest użytkowane w sposób inny niż określony przez producenta, zabezpieczenie zapewniane przez urządzenie może zostać ograniczone. OBS! Läs detta dokument samt dokumentet, som står listat i avsnittet Övriga resurser, om installation, konfigurering och drift av denna utrustning innan du installerar, konfigurerar eller börjar använda eller utföra underhållsarbete på produkten. Användare måste bekanta sig med instruktioner för installation och kabeldragning, förutom krav enligt gällande koder, lagar och standarder. Åtgärder som installation, justering, service, användning, montering, demontering och underhållsarbete måste utföras av personal med lämplig utbildning enligt lämpligt bruk. Om denna utrustning används på ett sätt som inte anges av tillverkaren kan det hända att utrustningens skyddsanordningar försätts ur funktion. LET OP: Lees dit document en de documenten die genoemd worden in de paragraaf Aanvullende informatie over de installatie, configuratie en bediening van deze apparatuur voordat u dit product installeert, configureert, bediend of onderhoudt. Gebruikers moeten zich vertrouwd maken met de installatie en de bedradingsinstructies, naast de vereisten van alle toepasselijke regels, wetten en normen. Activiteiten zoals het installeren, afstellen, in gebruik stellen, gebruiken, monteren, demonteren en het uitvoeren van onderhoud mogen uitsluitend worden uitgevoerd door hiervoor opgeleid personeel en in overeenstemming met de geldende praktijkregels. Indien de apparatuur wordt gebruikt op een wijze die niet is gespecificeerd door de fabrikant, dan bestaat het gevaar dat de beveiliging van de apparatuur niet goed werkt. 2 Rockwell Automation Publication 1794-IN049E-EN-P - May 2022 FLEX I/O 2-input Frequency Modules Installation Instructions Environment and Enclosure ATTENTION: This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in EN/IEC 60664-1), at altitudes up to 2000 m (6562 ft) without derating. This equipment is not intended for use in residential environments and may not provide adequate protection to radio communication services in such environments. This equipment is supplied as open-type equipment for indoor use. It must be mounted within an enclosure that is suitably designed for those specific environmental conditions that will be present and appropriately designed to prevent personal injury resulting from accessibility to live parts. The enclosure must have suitable flame-retardant properties to prevent or minimize the spread of flame, complying with a flame spread rating of 5VA or be approved for the application if nonmetallic. The interior of the enclosure must be accessible only by the use of a tool. Subsequent sections of this publication may contain more information regarding specific enclosure type ratings that are required to comply with certain product safety certifications. In addition to this publication, see the following: • Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1, for additional installation requirements. • NEMA Standard 250 and IEC 60529, as applicable, for explanations of the degrees of protection provided by enclosures. WARNING: If you insert or remove the module while backplane power is on, an electrical arc can occur. This could cause an explosion in hazardous location installations. Be sure that power is removed or the area is nonhazardous before proceeding. WARNING: If you connect or disconnect wiring while the field-side power is on, an electrical arc can occur. This could cause an explosion in hazardous location installations. Be sure that power is removed or the area is nonhazardous before proceeding ATTENTION: Personnel responsible for the application of safety-related Programmable Electronic Systems (PES) shall be aware of the safety requirements in the application of the system and shall be trained in using the system ATTENTION: Do not remove or replace a Terminal Base unit while power is applied. Interruption of the backplane can result in unintentional operation or machine motion. ATTENTION: This product is grounded through the DIN rail to chassis ground. Use zinc-plated chromate-passivated steel DIN rail to assure proper grounding. The use of other DIN rail materials (for example, aluminum or plastic) that can corrode, oxidize, or are poor conductors, can result in improper or intermittent grounding. Secure DIN rail to mounting surface approximately every 200 mm (7.8 in.) and use end-anchors appropriately. Be sure to ground the DIN rail properly. See the Industrial Automation Wiring and Grounding Guidelines, Rockwell Automation publication 1770-4.1, for more information. Prevent Electrostatic Discharge ATTENTION: This equipment is sensitive to electrostatic discharge, which can cause internal damage and affect normal operation. Follow these guidelines when you handle this equipment: • Touch a grounded object to discharge potential static. • Wear an approved grounding wriststrap. • Do not touch connectors or pins on component boards. • Do not touch circuit components inside the equipment. • Use a static-safe workstation, if available. • Store the equipment in appropriate static-safe packaging when not in use. ATTENTION: To reduce susceptibility to noise, power analog modules and digital modules from separate power supplies. Do not exceed a total length of 9.8 ft (3 m) for DC power cabling. Rockwell Automation Publication 1794-IN049E-EN-P - May 2022 3 FLEX I/O 2-input Frequency Modules Installation Instructions European Hazardous Location Approval The following applies to products marked II 3 G: • Are intended for use in potentially explosive atmospheres as defined by European Union Directive 2014/34/EU and has been found to comply with the Essential Health and Safety Requirements relating to the design and construction of Category 3 equipment intended for use in Zone 2 potentially explosive atmospheres, given in Annex II to this Directive. • Compliance with the Essential Health and Safety Requirements has been assured by compliance with EN 60079-15 and EN 60079-0. • Are Equipment Group II, Equipment Category 3, and comply with the Essential Health and Safety Requirements relating to the design and construction of such equipment given in Annex II to EU Directive 2014/34/EU. See the EU Declaration of Conformity at rok.auto/certifications for details. • The type of protection is Ex nA IIC T4 Gc according to EN 60079-15. • Comply to Standards EN 60079-0:2012, EN 60079-15:2010, reference certificate number DEMKO 14 ATEX 1342501X. • Are intended for use in areas in which explosive atmospheres caused by gases, vapors, mists, or air are unlikely to occur, or are likely to occur only infrequently and for short periods. Such locations correspond to Zone 2 classification according to ATEX directive 2014/34/EU. IEC Hazardous Location Approval The following applies to products with IECEx certification: • Are intended for use in areas in which explosive atmospheres caused by gases, vapors, mists, or air are unlikely to occur, or are likely to occur only infrequently and for short periods. Such locations correspond to Zone 2 classification to IEC 60079-0. • The type of protection is Ex nA IIC T4 Gc according to IEC 60079-15. • Comply to Standards IEC 60079-0: 2011, IEC 60079-15: 2010 reference IECEx certificate number IECEx UL 14.0066X. WARNING: Special Conditions for Safe Use: • This equipment is not resistant to sunlight or other sources of UV radiation. • This equipment shall be mounted in an ATEX/IECEx Zone 2 certified enclosure with a minimum ingress protection rating of at least IP54 (in accordance with EN/IEC 60079-0) and used in an environment of not more than Pollution Degree 2 (as defined in EN/IEC 60664-1) when applied in Zone 2 environments. The enclosure must be accessible only by the use of a tool. • This equipment shall be used within its specified ratings defined by Rockwell Automation. • Provision shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 140% of the peak rated voltage when applied in Zone 2 environments. • This equipment must be used only with ATEX/IECEx certified Rockwell Automation backplanes. • Secure any external connections that mate to this equipment by using screws, sliding latches, threaded connectors, or other means provided with this product. • Do not disconnect equipment unless power has been removed or the area is known to be nonhazardous. • Earthing is accomplished through mounting of modules on rail. • Devices shall be used in an environment of not more than Pollution Degree 2. North American Hazardous Location Approval The Following Information Applies When Operating This Equipment In Hazardous Locations. Informations sur l’utilisation de cet équipement en environnements dangereux. Products marked "CL I, DIV 2, GP A, B, C, D" are suitable for use in Class I Division 2 Groups A, B, C, D, Hazardous Locations and nonhazardous locations only. Each product is supplied with markings on the rating nameplate indicating the hazardous location temperature code. When combining products within a system, the most adverse temperature code (lowest "T" number) may be used to help determine the overall temperature code of the system. Combinations of equipment in your system are subject to investigation by the local Authority Having Jurisdiction at the time of installation. Les produits marqués "CL I, DIV 2, GP A, B, C, D" ne conviennent qu'à une utilisation en environnements de Classe I Division 2 Groupes A, B, C, D dangereux et non dangereux. Chaque produit est livré avec des marquages sur sa plaque d'identification qui indiquent le code de température pour les environnements dangereux. Lorsque plusieurs produits sont combinés dans un système, le code de température le plus défavorable (code de température le plus faible) peut être utilisé pour déterminer le code de température global du système. Les combinaisons d'équipements dans le système sont sujettes à inspection par les autorités locales qualifiées au moment de l'installation. WARNING: Explosion Hazard – • Do not disconnect equipment unless power has been removed or the area is known to be nonhazardous. • Do not disconnect connections to this equipment unless power has been removed or the area is known to be nonhazardous. Secure any external connections that mate to this equipment by using screws, sliding latches, threaded connectors, or other means provided with this product. • Substitution of components may impair suitability for Class I, Division 2. AVERTISSEMENT: Risque d’Explosion – • Couper le courant ou s'assurer que l'environnement est classé non dangereux avant de débrancher l'équipement. • Couper le courant ou s'assurer que l'environnement est classé non dangereux avant de débrancher les connecteurs. Fixer tous les connecteurs externes reliés à cet équipement à l'aide de vis, loquets coulissants, connecteurs filetés ou autres moyens fournis avec ce produit. • La substitution de composants peut rendre cet équipement inadapté à une utilisation en environnement de Classe I, Division 2. 4 Rockwell Automation Publication 1794-IN049E-EN-P - May 2022 FLEX I/O 2-input Frequency Modules Installation Instructions Install Your Frequency Input Module 7 1 3 2 6 4 5 ATTENTION: During mounting of all devices, be sure that all debris (metal chips, wire strands, and so on) is kept from falling into the module. Debris that falls into the module could cause damage on power-up. The FLEX™ I/O 2-input frequency modules mounts on a 1794-TB3G or 1794-TB3G-TB3GS terminal base. 1. 2. 3. Rotate the keyswitch (1) on the terminal base (2) clockwise to position 1 as required for this type of module. Make sure that the Flexbus connector (3) is pushed all the way to the left to connect with the neighboring terminal base/adapter. You cannot install the module unless the connector is fully extended. Make sure that the pins on the bottom of the module are straight so that they align properly with the connector in the terminal base. WARNING: If you remove or insert the module while the backplane power is on, an electrical arc can occur. This could cause an explosion in hazardous location installations. Be sure that power is removed or the area is nonhazardous before proceeding. 4. 5. Position the module (4) with its alignment bar (5) aligned with the groove (6) on the terminal base. Press firmly and evenly to seat the module in the terminal base unit. The module is seated when the latching mechanism (7) is locked into the module. Connecting Wiring for the 1794-TB3G and 1794-TB3GS Terminal Base Unit Connect wiring as shown in Figure 1 on page 6. ATTENTION: To reduce susceptibility to noise, power analog modules and digital modules from separate power supplies. Do not exceed a length of 3 m (9.8 ft) for DC power cabling. ATTENTION: Do not daisy chain power or ground from this terminal base unit to any AC or DC digital module terminal base units. Rockwell Automation Publication 1794-IN049E-EN-P - May 2022 5 FLEX I/O 2-input Frequency Modules Installation Instructions Figure 1 - Wiring Connections using 1794-TB3G or 1794-TB3GS Terminalg Base Unit 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A 3V 16 6V 17 24V RET PWR 50 500/50 F mV mV SEL SEL Channel 0 Frequency Input 18 19 20 21 RET 24V F 500/50 50 mV PWR mV SEL SEL Channel 1 Frequency Input 24V 24V PWR PWR 22 23 24 25 26 27 28 29 6V 30 3V 31 32 33 B Chassis OUT 0 OUT 0 Ground RET 34 35 +V COM RET 50 500/50 G mV mV SEL SEL Channel 0 Gate Input NC 36 37 38 39 40 24V 24V PWR PWR 41 42 RET NC G 500/50 50 mV mV SEL SEL Channel 1 Gate Input 43 44 45 46 47 OUT 1 OUT 1 Chassis RET Ground 48 49 50 51 NC +V COM C 24V DC Supply In NC Sply0 Chassis Sply0 Ground RET Sply1 Chassis Sply1 Ground RET Chassis Grounds for Shields Channel 0 Output Supply +24V DC = Terminals C-34 and C-50 COM = C-35 and C-51 Chassis Ground = Terminals B-16, B-33, C-38, C-40...45, and C-47 NC = No connection For daisy chaining: Supply in - C-34 (+) and C-35 (-) Supply out - C-50 (+) and C-51 (-) Output Alarm Connections Supply Output Channel 0 Terminals(1) Sply + Sply RET C-37 C-39 24V DC Supply Out Channel 1 Output Supply Out + Out RET B-17 B-18 (1794-TB3G shown) Channel 1 Terminals(1) Sply + Sply RET C-46 C-48 Out + Out RET B-31 B-32 (1) Connect cable shields to GND connections. Channel 0 Terminals(1) Types of Inputs Channel 1 Terminals(1) Power Input RET(2) Power Input RET(2) A-7 A-6 A-3 A-8 A-9 A-12 24V DC Contact Switch 500 mV AC Magnetic Pickup A-7 A-6 A-3 A-8 A-9 A-12 A-7 A-5 A-3 A-8 A-10 A-12 (6) A-7 A-5 A-3 A-8 A-10 A-12 A-2 A-2 A-1 A-0 A-3 A-3 A-13 A-13 A-14 A-15 A-12 A-12 B-24 B-23 B-20 B-25 B-26 B-29 Frequency 24V DC IEC 1+ Proximity(3), (4) (5) 50 mV AC Magnetic Pickup 6V AC Vortex 3V AC Vortex Gate 24V DC IEC 1+ Proximity(3), (4) (5) 24V DC Contact Switch 500 mV DC Magnetic Pickup B-24 B-23 B-20 B-25 B-26 B-29 B-24 B-22 B-20 B-25 B-27 B-29 50 mV DC Magnetic Pickup(6) B-24 B-22 B-20 B-25 B-27 B-29 (1) (2) (3) (4) (5) (6) 6 Connect cable shields to GND terminals All four RET terminals (ch0 and 1, Freq. and Gate) are internally connected together. As defined by standard IEC 1131-2. RET not used on 2-wire devices. Add external resistor from 24V to F (A-6) or G (A-9) for wire-off detection (0.4 mA). Add jumper between 50 mV and RET (frequency - channel 0 = A-4…A-3; channel 1 = A-11…A-12) Rockwell Automation Publication 1794-IN049E-EN-P - May 2022 GND(1) FLEX I/O 2-input Frequency Modules Installation Instructions Resolution and Accuracy +1 Hz or +0.1 Hz (depending on frequency range bit setting), or + accuracy specification listed in Table 1, whichever is greater. Resolution % is defined as: % Resolution = 100 count frequency x minimum frequency sample time Accuracy % is defined as: % Accuracy = 100 1- Minimum frequency sample time 2 Minimum frequency 1 + sample time count frequency 2 Table 1 - Accuracy Specifications Accuracy Min. Freq. Sample Time (ms) Sampling Accuracy Case Total Time Base Accuracy Worst Accuracy 2 4 5 10 20 50 100 200 500 1000 +0.02% +0.01% +0.008% +0.004% +0.002% +0.0008% +0.0004% +0.0002% +0.00008% +0.00004% +0.0225% +0.0225% +0.0225% +0.0225% +0.0225% +0.0225% +0.0225% +0.0225% +0.0225% +0.0225% +0.0425 +0.0325 +0.0305 +0.0265 +0.0245 +0.0233 +0.0229 +0.0227 +0.02258 +0.02254 Deviation in Hz Due to Total Accuracy 1.0…3276.7 Freq. Range 1…32767 Freq. Range (in Hz) (in Hz) +0.1…1.4 +1…14 +0.1…1.1 +1…11 +0.1…1.0 +1…10 +0.1…0.9 +1…9 +0.1…0.8 +1…8 +0.1…0.8 +1…8 +0.1…0.8 +1…8 +0.1…0.7 +1…7 +0.1…0.7 +1…7 +0.1…0.7 +1…7 Resolution 0.01% 0.005% 0.004% 0.002% 0.001% 0.0004% 0.0002% 0.0001% 0.00004% 0.00002% Table 2 - Input Map Bit Word 0 1 2 3 4 5 15 14 13 12 11 10 09 08 07 06 Read Frequency 0…32,767 or 0.0…3,276.7 Channel 0 % Full Scale 0.0…3,276.7% Channel 0 or Acceleration -32,768…32,767 Channel 0 Frequency 0…32,767 or 0.0…3,276.7 Channel 1 % Full Scale 0.0…3,276.7% Channel 1 or Acceleration -32,768…32,767 Channel 1 GS R R Direction CH 0 F/A CH 0 WO CH 0 MPA CH 0 R R CH 0 Diagnostic Status Reserved Reserved Channel 0 Reserved 05 04 Direction CH 1 03 02 01 00 GS F/A CH 1 WO CH 1 MPA CH 1 CH 1 Diagnostic Status Channel 1 6 Where: GS = Gate state F/A = Frequency/Accel alarm WO = Wire-off alarm MPA = Missing pulse alarm R = Reserved Rockwell Automation Publication 1794-IN049E-EN-P - May 2022 7 FLEX I/O 2-input Frequency Modules Installation Instructions Table 3 - Output Map Dec. Oct. 15 17 14 16 13 15 12 14 11 13 10 12 9 11 8 10 0 CF SSM FR CH 0 Number of pulses to terminate sampling 0…7 CH 0 MPM 0…3 CH 0 7 7 6 6 R LF 5 5 4 4 3 3 2 2 1 0 1 0 0…3 of pulses to terminate MPM FR CH 1 Number CH 1 sampling 0…7 CH 1 1 2 Maximum Frequency 0…32.767 or 0.0…3,276.7 or Absolute Value of Acceleration - 0…32767 Channel 0 Frequency Scaling Divisor 0…255 Channel 0 Frequency Scaling Multiplier 0…255 Channel 0 Minimum Frequency Sample Time 0…15 Init St Up ACT 0…3 3 WOFG CH 0 WOFF CH 0 IGI CH 0 IFI CH 0 CH 0 F/AAS CH 0 MPDM 0…3 CH 0 CH 0 CH 0 4 Maximum Frequency 0…32,767 or 0.0…3,276.7 or Absolute Value of Acceleration - 0…32,767 Channel 1 5 Frequency Scaling Divisor 0…255 Channel 1 Frequency Scaling Multiplier 0…255 Channel 1 Minimum Frequency Sample Time 0…15 Init St Up ACT 0…3 6 WOFG CH 1 WOFF CH 1 IGI CH 1 IFI CH 1 CH 1 F/AAS CH 1 MPDM 0…3 CH 1 CH 1 CH 1 7 Reserved Where: CF = Communication Fault SSM = Safe state mode FR = Frequency range MPM = Missing pulse multiplier LF = Local Fault mode F/AAS = Frequency/Accel alarm select WOFF = Wire-off fault frequency WOFG = Wire-off fault gate WOFM = Wire-off fault mode IGI = Invert gate input IFI = Invert frequency input ACT = Acceleration calculation time MPDM = Missing pulse delay multiplier R = Reserved WOFM 0…3 CH 0 WOFM 0…3 CH 1 Interpret Status Indicators Allen-Bradley 1794-IJ2 1794-IJ2 shown FREQUENCY INPUT 2 CHANNEL 1 FREQ F 0 A GATE 0 F FREQ 1 F B GATE 1 F C OUT 0 D OUT 1 OK E A = Input indicator B = Insertable label for writing individual I/O assignments C = Wire-off Fault indicator D = Output indicator E = Power/status indicator – indicates power applied to module and status of module When an input indicator (yellow) is lighted, it indicates that a valid signal (active high or active low) is present at one of the Input terminals. When wire-off detection is enabled, and a wire-off fault is detected (24V DC IEC 1+ input terminal only), a fault indicator (red) is blinked/flashed at a rate of 1 Hz to signal a fault condition. A wire-off fault signal is sent to the backplane. A flashing red fault indication means a valid wire-off condition for a 24V DC IEC 1+ Input or a 24V DC contact switch input with a shunt resistor. When an output indicator is yellow, the logic is driving an output alarm On. After detecting a fault, the internal circuitry will set the output data to the appropriate safe state, as defined by the module data table. Safe state control may be adapter-dependent. The input and output indicators are on the field side of the isolation path, and display the logic state of the actual micro controller input and output. The status indicator initially powers up as solid green, indicating the power supply is operating and internal diagnostic tests are being performed. After a successful power-up test, the indicator remains green. The indicator turns red in about 1.5 s if there is an internal diagnostics error. The module is operating correctly when the green OK indicator is on. A red OK indicator shows that the module is in a Faulted condition (internal error). 8 Rockwell Automation Publication 1794-IN049E-EN-P - May 2022 FLEX I/O 2-input Frequency Modules Installation Instructions Table 4 - Status Indicators Description Indicator Condition Off (Dark) On (Yellow) Off (Dark) On (Red Flashing) Off (Dark) On (Yellow) Off (Dark) Solid Green Solid Red Input (0, 1) (Freq, or Gate) Fault (F) (Freq, or Gate) Output Alarm (0, 1) Status (OK) Operating Description Input Turned Off, Input Not Used, or Wire Disconnected Input Turned On (Active High or Active Low if Inverted) Wire Connected, Normal Operation or Detection Disabled Wire Disconnected, Fault Condition (for IEC 1+ Proximity switch or switch contacts with shunt resistor) Output Alarm Turned Off Output Alarm Turned On (Logic Drive On) 24V Power Turned Off, or 5V Logic Power Problem Module OK, Normal Operating Mode Module Fault, Outputs Disabled Diagnostics The frequency input module returns diagnostics to the controller processor in word 5 of the BTR file. These diagnostics give you information on the status or condition of the module. BTR Word 5 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00 word 5 See Table 5 for diagnostics Table 5 - Diagnostic Bit Definition Input Word Bit Word 5 Bits 00...03 03 0 0 02 0 0 01 0 0 00 0 1 Definition 0 = Normal Operation (No Failure) 1 = Calibration Failure 2 = Configuration Failure 0 0 1 0 A Minimum Frequency Sample Time value other than 0…9 was selected. 0 0 1 1 3 = Message Failure 0 1 0 0 4 = Lead Break Detection Hardware Failure 0 1 0 1 5 = Major Hardware Failure 0 1 1 0 6 = EEPROM Failure 0 1 1 1 7 = RAM Failure 1 0 0 0 8 = ROM Failure 9 = Calculation Failure The actual Frequency is greater than 32,767 Hz or 3,276.7 Hz (overange). The scaled Frequency 1 0 0 1 is greater than 32,767 Hz or 3,276.7 Hz (overange). The % Full Scale calculation (based on Max Frequency) is > 3,276.7%. 1010...1111 10...15 = Not used Diagnostic Status - indicates the response from the module; a normal or non-normal operating condition. Rockwell Automation Publication 1794-IN049E-EN-P - May 2022 9 FLEX I/O 2-input Frequency Modules Installation Instructions Specifications Input Specifications Attribute Value Number of input channels Number of inputs per channel Input frequency, max Frequency value, max Input pulse width Resolution/Accuracy On-stage voltage, min 2 2 - Frequency and Gate (gate used to establish direction) 1…32 kHz w/sine wave; 1…32 kHz w/square wave input 32,767 or 3,276.7 (dependent on range) 20 µs See Resolution and Accuracy on page 7 10V (24V IEC+1 proximity, encoder input or switch inputs) 50 mV AC, 28V AC peak - Extended Magnetic Pickup 500 mV AC, 28V AC peak - Magnetic Pickup < 3V - Vortex Flowmeter low range > 6V - Vortex Flowmeter high range 24V DC IEC+1 proximity or encoder input 24V DC Contact Switch input Limited to isolated 24V DC power supply On-state voltage, nom (selected by terminal base connections) On-state voltage, max On-state current min nom max Off-state current, min Off-state voltage, max Wire-off detection Frequency input impedance Gate input impedance 2.0 mA 9.0 mA 10.0 mA 1.5 mA into 24V DC IEC+ terminal 5.0V DC on 24V DC IEC+1 terminal 0.4 mA for proximity, encoder, or contact switch with 50 kΩ shunt resistor > 5 kΩ for 50 mV Extended Magnetic Pickup > 5 kΩfor 500 mV Magnetic Pickup > 10 kΩ for 3V Vortex Flowmeter low range > 10 kΩ for 6V Vortex Flowmeter high range > 2.5 kΩ for 24V DC IEC+1 proximity or encoder input > 2.5 kΩ for 24V DC Contact Switch input > 5 KΩ for 50 mV Extended Magnetic Pickup > 5 KΩ for 500 mV Magnetic Pickup > 2.5 KΩ for 24V DC IEC+1 proximity or encoder input > 2.5 KΩ for 24V DC Contact Switch input Output Specifications (meets IEC 1A 24V DC output specifications) Attribute Value Number of outputs Output voltage source Output voltage min nom max Off-state voltage, max 2 isolated Customer supplied On-state current Surge current Off-state leakage, max On-state voltage drop Output control Output switching time 10 10V DC 24V DC 31.2V DC 31.2V DC 1 mA per output min 1.0 A per channel sourced out of module max Current Limited - All outputs can be on simultaneously without derating 2 A for 50 ms, repeatable every 2 s Less than 300 µA at 31.2V DC 0.9V DC at 1 A Outputs individually assignable to: Frequency, % Full Scale, or Acceleration Alarm Triggered by frequency alarm or acceleration alarm Turn on: Less than 0.5 ms Turn off: Less than 1 ms Rockwell Automation Publication 1794-IN049E-EN-P - May 2022 FLEX I/O 2-input Frequency Modules Installation Instructions General Specifications Attribute Value Module location External DC power Voltage range Supply voltage, nom Supply current Isolated DC power Voltage range Supply voltage, nom Supply current, max Peak AC ripple, max Dimensions (with module installed in base), (H x W x D) 1794-TB3G and 1794-TB3GS Terminal Base Units (Input for +5V logic and 24V DC/DC converters) 19.2…31.2V DC (includes 5% AC ripple) 24V DC 220 mA @ 19.2V DC; 180 mA @ 24V DC; 140 mA @ 31.2V DC (Output to sensors and encoders) 21.6…26.4V DC 24V DC 0…60 mA @ 24V DC (4 devices @ 15 mA = 60 mA) 100 mV Isolation voltage 50V (continuous), Basic Insulation Type Type tested at 1365V AC for 60 s, between field side and system and individual channels < 4 ms 30 mA at 5V DC 4.6 W at 31.2V DC 15.6 BTU/hr at 31.2V DC 1 green/red power/status indicator 4 yellow status indicators (Freq 0, 1, Gate 0, 1) 4 red wire-off indicators (Freq 0, 1, Gate 0, 1) 2 yellow status indicators (Out 0, Out 1) - logic side 1 Determined by installed terminal base 2 - on signal ports 3 - on power ports Shielded on signal ports Determined by installed terminal base None (open-style) T4A T4 T4 Processing time Flexbus current Power dissipation, max Thermal dissipation, max Indicators (field side driven, logic side indication) Keyswitch Position Wire size Wiring category(1) Wire type Terminal screw torque Enclosure type rating North American temp code IECEx temp code ATEX temp code 94 x 94 x 69 mm (3.7 x 3.7 x 2.7 in.) (1) Use this conductor category information for planning conductor routing. See the Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. Environmental Specifications Attribute Temperature, operating Temperature, surrounding air, max Temperature, nonoperating Relative humidity Vibration Shock, operating Shock, nonoperating Emissions Value IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock): 0…55 °C (32…131 °F) (1794-IJ2) -20…+70 °C (-4…+158 °F) (1794-IJ2XT) 55 °C (131 °F) (1794-IJ2) 70 °C (158 °F) (1794-IJXT) IEC 60068-2-1 (Test Ab, Unpackaged nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged nonoperating Thermal Shock): -40…+85 °C (-40…+185 °F) IEC 60068-2-30 (Test Db, Unpackaged Damp Heat): 5…95% noncondensing IEC 60068-2-6 (Test Fc, Operating): 5 g @ 10…500 Hz IEC 60068-2-27 (Test Ea, Unpackaged Shock): 30 g IEC 60068-2-27 (Test Ea, Unpackaged Shock): 50 g IEC 61000-6-4 Rockwell Automation Publication 1794-IN049E-EN-P - May 2022 11 FLEX I/O 2-input Frequency Modules Installation Instructions Environmental Specifications (Continued) Attribute ESD immunity Radiated RF immunity EFT/B immunity Surge transient immunity Conducted RF immunity Value IEC 61000-4-2: 4 kV contact discharges (1794-IJ2) 6 kV contact discharges (1794-IJ2XT) 8 kV air discharges IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80…6000 MHz IEC 61000-4-4: ±2 kV at 5 kHz on power ports ±2 kV at 5 kHz on signal ports IEC 61000-4-5: ±2 kV line-earth(CM) on shielded signal ports IEC 61000-4-6: 10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz on shielded signal ports Certifications Attribute (when product is marked)(1) c-UL-us Ex IECEx CE RCM TÜV KC EAC Morocco CCC Value UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E194810. European Union 2014/34/EU ATEX Directive, compliant with: EN 60079-0; General Requirements EN 60079-15; Potentially Explosive Atmospheres, Protection "n" II 3 G Ex nA IIC T4 Gc DEMKO 14 ATEX 1342501X IECEx System, compliant with: IEC 60079-0; General Requirements IEC 60079-15; Potentially Explosive Atmospheres, Protection "n" II 3 G Ex nA IIC T4 Gc IECEx UL 14.0066X European Union 2014/30/EU EMC Directive, compliant with: EN 61326-1; Meas./Control/Lab., Industrial Requirements EN 61000-6-2; Industrial Immunity EN 61000-6-4; Industrial Emissions EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) European Union 2011/65/EU RoHS, compliant with: EN 50581; Technical documentation Australian Radiocommunications Act, compliant with: EN 61000-6-4; Industrial Emissions TÜV Certified for Functional Safety: up to and including SIL 2 Korean Registration of Broadcasting and Communications Equipment, compliant with: Article 58-2 of Radio Waves Act, Clause 3 Russian Customs Union TR CU 020/2011 EMC Technical Regulation Arrêté ministériel n° 6404-15 du 29 ramadan 1436 CNCA-C23-01:2019 CCC Implementation Rule Explosion-Proof Electrical Products, compliant with: GB 3836.1-2010 Explosive atmospheres — Part 1: Equipment — General requirements GB 3836.8-2014 Explosive atmospheres - Part 8: Equipment protection by type of protection “n” (1) See the Product Certification link at rok.auto/certifications for Declarations of Conformity, Certificates, and other certification details. 12 Rockwell Automation Publication 1794-IN049E-EN-P - May 2022 FLEX I/O 2-input Frequency Modules Installation Instructions Notes: Rockwell Automation Publication 1794-IN049E-EN-P - May 2022 13 Rockwell Automation Support Use these resources to access support information. Technical Support Center Knowledgebase Local Technical Support Phone Numbers Literature Library Product Compatibility and Download Center (PCDC) Find help with how-to videos, FAQs, chat, user forums, and product notification updates. Access Knowledgebase articles. Locate the telephone number for your country. Find installation instructions, manuals, brochures, and technical data publications. Download firmware, associated files (such as AOP, EDS, and DTM), and access product release notes. rok.auto/support rok.auto/knowledgebase rok.auto/phonesupport rok.auto/literature rok.auto/pcdc Documentation Feedback Your comments help us serve your documentation needs better. If you have any suggestions on how to improve our content, complete the form at rok.auto/docfeedback. Waste Electrical and Electronic Equipment (WEEE) At the end of life, this equipment should be collected separately from any unsorted municipal waste. Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec. Rockwell Otomasyon Ticaret A.Ş. Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400 EEE Yönetmeliğine Uygundur Connect with us. Allen-Bradley, expanding human possibility, FactoryTalk, FLEX, Rockwell Automation, and TechConnect are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Publication 1794-IN049E-EN-P - May 2022 | Supersedes Publication 1794-IN049D-EN-P - January 2009 Copyright © 2022 Rockwell Automation, Inc. All rights reserved. ">
Advertisement