Page 1
VANGUARD GOLD MOBILE
EXTRAORAL SUCTION
Warnings and Precautions
This dust collector is designed to run on 115 volt alternating current, 60 Hz
supply voltage in temperatures ranging from -10 to +40 degrees celcius. With
a maximum current usage of 15 amps. The plug on the unit labeled “Power”
is for the supply line cord provided. The supply plug in the wall must have a
wired ground and if the back cover is removed for any reason, do not bypass the
protective earthing.
This dust collector is to be used for capturing fine aerosols. Not suitable for
direct liquid suction.
When placing the unit in a location be sure that the power connector is
accessible at all times. Any side of the dust collector that has a vent on it must
be a minimum of 2 inches from any obstruction, and have a vent area of 20
square inches to allow ventilation to ambient room air. This will keep the unit cool
and ensure a longer motor life.
Failure to comply with the precautions listed here or any others for this
equipment may cause electrical shock or equipment failure.
- Alternating Current
- Caution, risk of electrical shock
25799 Jefferson Ave. Murrieta, CA 92562 ● 1-800-VANIMAN (826-4626) ● www.vaniman.com ● [email protected]
VANGUARD GOLD MOBILE REV1 06/20
Page 2
VANGUARD GOLD MOBILE
EXTRAORAL SUCTION
2
Replacement Parts
3
Fig. #
Description
Part Number
1
Caster Wheels
3140
2
Flex Hose - 3’
96001
2
Flex Hose - 1’
96002
3
Rectangular Nozzle
(5 pack)
96090
Not Shown
HEPA Filter Cartridge
97016
Optional
Round Nozzle (5 pack) 96091
Not Shown
Foot Remote/Bellows
1443
1
PACKING LIST
1 - Vanguard Gold Mobile
1 - Internal HEPA Filter
1 - Power Cord
1 - 4’ Flex Hose
4 - Caster Wheels
1 - Foot Remote/Bellows
Tools Needed: Wrench (1/2” or adjustable)
IMPORTANT SERVICE INFORMATION:
SAVE SHIPPING BOX AND FOAM FOR FUTURE
SERVICE. SHIPPING WITHOUT PROPER FOAM
MAY CAUSE DAMAGE TO UNIT
ASSEMBLY INSTRUCTIONS
1. Remove the four caster wheels from the bag packed with the Flex Hose. Lay the unit on its back
on top of several pieces of foam packaging to protect it. Screw the four caster wheels into the four
threaded holes in the bottom of the unit. Tighten them with a wrench.
2. Connect the Flex Hose kit to the inlet tube on the top of the unit. Adjust the Flex Hose to the desired
position.
3. Plug the removable power cord into the socket on the top of the unit. Plug the other end into a standard grounded wall socket. Connect the black foot remote tube to the black remote switch connector
on the unit; test by turning the power switch on or by pressing the foot remote. Located on the top of
the unit is the On/Off switch. Turn the unit on and adjust the amount of suction by turning the rotary
selector. The unit can be turned on and off by depressing the foot remote.
DISINFECTION INSTRUCTIONS
1. Using disinfectant, spray outside and inside of Flex Hose between sessions. Unit may remain on
during this step.
25799 Jefferson Ave. Murrieta, CA 92562 ● 1-800-VANIMAN (826-4626) ● www.vaniman.com ● [email protected]
VANGUARD GOLD MOBILE REV1 06/20
Page 3
VANGUARD GOLD MOBILE
EXTRAORAL SUCTION
2. Nozzle can be removed and washed with hot soapy water, or cold sterilized. Nozzle is not autoclavable.
FILTER REPLACEMENT INSTRUCTIONS
*** To prevent additional spread of virus or bacteria, it’s advised to contact the CDC for proper handling
protocol with specific pathogens***
1. Turn off the unit.
2. Wearing full PPE (per the CDCs recommendations), set aside a sealable bag for disposing the
filter(s).
3. Remove the two thumb screws on the front of unit and set aside for later use.
4. Remove the panel to expose the filter bag and HEPA filter. For filter bag replacement continue to
step 5. For HEPA filter replacement continue to step 6.
5. Filter bag should be replaced at least once every 3 months. Firmly grab filter bag at the connection
point and pull down. A rocking motion may be required. Place filter bag into a sealable bag. Disinfect
the inside of the unit. Holding the replacement filter bag by ridged opening, secure the filter bag onto
the inlet until there is no space between the top of the unit and the filter bag.
If only replacing the filter bag please proceed to step 7.
6. The HEPA filter should be replaced every 6-12 months. To change HEPA filter, remove the filter
access panel (front cover) from the dust collector, and remove the filter bag from the unit or lift it up
to expose the filter slot. Remove HEPA filter by pulling on tab and place into sealable bag for disposal. Remove any packaging from the replacement HEPA filter, carefully align the filter frame over
the filter slot, then slide the filter into place with the filter gasket facing upwards. Replace HEPA filter
when the filter becomes excessively dirty.
7. Put the front panel back on the unit and secure with thumb screws.
8. Dispose of the sealed bag containing the used filter(s) per the CDCs recommendations.
MAINTENANCE
1. Circuit Breaker - The unit is protected by a circuit breaker on the right side of the unit. In the
unlikely event there is an overload condition the breaker may trip. If this happens reset the breaker
by pushing on the white button until it clicks into place.
2. Motor Protection - If the motor becomes too hot it will automatically shutoff to prevent damage. To
reset the thermal gauge, turn off or unplug the unit and allow the motor to cool down. Once it has
cooled you may turn it back on and continue use.
3. Motor Brushes - This long life motor does not have replaceable brushes. Replacement motors can
be ordered as P/N 97041.
25799 Jefferson Ave. Murrieta, CA 92562 ● 1-800-VANIMAN (826-4626) ● www.vaniman.com ● [email protected]
VANGUARD GOLD MOBILE REV1 06/20
Page 4
VANGUARD GOLD MOBILE
EXTRAORAL SUCTION
REPLACEMENT PARTS
The following items are offered to enhance the usage of your quality Vaniman unit. These items can be
order through your supplier using the following part numbers. Please feel free to contact Vaniman Mfg.
Co. with questions regarding our products.
Fig. #
1
2
3
4
Description
Replacement Motor
Motor Mount
Motor Clip
Replacement Filter Bag 3-pack
Part Number
97041
2921
97040
VMC-A400-3
5
6
7
Not Shown
8
9
10
11
12
13
Not Shown
Replacement Filter Bag 5-pack
Front Cover Thumb Screws
Remote Plug Air Switch
Power Switch ON/OFF
Protective Switch Cover
Power Connector
Rotary Switch Knob
Rotary Switch
Transformer
Circuit Breaker, 15Amp
Back Cover Screw 6-32 X 3/8” FHSMS
Power Cord
VMC-A400-5
2984
1442
2904
1003B
3010
1471
3019
1419
2869
1448A
1422
7
4
8
9
6
10
5
11
13
3
12
2
1
25799 Jefferson Ave. Murrieta, CA 92562 ● 1-800-VANIMAN (826-4626) ● www.vaniman.com ● [email protected]
VANGUARD GOLD MOBILE REV1 06/20
Page 1
HEPA FILTER
PACKING LIST
1 - HEPA Filter with Gasket
ABOUT THE PRODUCT
This filter kit is designed to make your job more comfortable and safer by removing 99.97% of dust,
airborne particles, and any other materials evacuated by the dust collector. The filter is designed to be
added to Vaniman Vanguard 1X and 2X, Van-I-Vac, and Voyager dust collectors internally. It is a HEPA
grade filter to insure effective filtration.
INSTALLATION INSTRUCTIONS
1. Remove the filter access panel (front cover) from the dust collector.
2. Remove the filter bag from the unit or lift it up to expose the filter slot on the unit.
3. Remove any packaging from the filter cartridge. Carefully align the frame opening over the filter slot
of the dust collector.
4. Slide the filter in to place with the gasket material facing upwards.
5. When the filter becomes excessively dirty, or suction is impeded, replace the HEPA cartridge.
25799 Jefferson Ave, Murrieta, CA 92562
1-800-VANIMAN (826-4626)
www.vaniman.com
[email protected]
HEPAFILTER-I-05/20
">