Advertisement
Advertisement
Quick Use Manual This document applies to the following series of products。 HF2421 http://www.iotworkshop.com 1 Copyright © 2013 . All rights reserved TABLE OF CONTENTS 1. 2. 3. HF2421General Description ............................................................................................ 3 1.1. HF2421Equipment shape and interface ................................................................. 3 Serial Tool Introduce .......................................................................................................... 3 2.1. Serial Tool SecureCRT .............................................................................................. 3 2.2. Setting Serial Port Parameters ................................................................................. 4 HF2421 Device parameter configuration ..................................................................... 5 3.1. IOTService Tool Introduction .................................................................................... 5 3.2. WEB ............................................................................................................................. 5 4. Transparent case One:W EB Configuration .............................................................. 6 5. Transparent test case two:IOTSerivice Tool Configuration ................................ 9 6. Web page upgrade firmware .......................................................................................... 11 Appendix 1 ................................................................................................................................... 12 HISTORY Ed. V1.0 11-04-2018 http://www.iotworkshop.com First Version. 2 Copyright © 2013 . All rights reserved 1. HF2421General Description The 4G serial server HF2421 provides RS232/RS485/RS422, Wi-Fi/Ethernet and 3G/4G. a protocol conversion between 1.1. HF2421Equipment shape and interface HF2421 Front view HF2421 Side interface diagram 2. Serial Tool Introduce 2.1. Serial Tool SecureCRT Download address: http://www.hi-flying.com/download-center-1/applications-1/download-item-secur ecrt Unzip the folder r and open SecureCRT, Click on the quick connect button http://www.iotworkshop.com 3 。 ,Create connection.。 Copyright © 2013 . All rights reserved 2.2. Setting Serial Port Parameters protocol:Serial port:The port that the computer is actually connected to (see "My Computer" -> "Device Manager" -> "Ports (COM and LPT)", as shown。) Baud rate:115200 Data bits:8 Parity :None Stop bit:1 Flow Control:None(Please remove "√" in front of RTS/CTS) Note: The default serial port data of the HF2421 device is as shown in the above figure. The user can modify the operating parameters of the product through the IOTService. This serial port software can be used to configure or transparently test the device. http://www.iotworkshop.com 4 Copyright © 2013 . All rights reserved 3. HF2421 Device parameter configuration There are three methods for the parameter configuration of Hanfeng industrial control device 1, IOTService tool 2, WEB page 3, serial port Cli command. This method document does not introduce. If you use to view the Cli commands in the user manual 3.1. IOTService Tool Introduction IOTService software is used to configure module operating parameters and remote management, view module status, upgrade, and other functions to facilitate device testing. The IOTService tool download URL is http://www.hi-flying.com/download-center-1/applications-1/download-item-iotservice 3.2. WEB Hanfeng Industrial Controls device also provides WEB web page configuration parameters. the PC is connected to the product's AP or the network cable is directly connected, enter the product default IP (10.10.100.254, default login user name and password: admin/admin) in the browser. You can log in to configure the parameters on the web page. Google, Firefox browser is recommended, browsers with 360 and below IE8 are not supported http://www.iotworkshop.com 5 Copyright © 2013 . All rights reserved 4. Transparent case One:WEB Configuration Application Scenario HF2421 Device Passes Data Through 4G Network。The following topology is shown。Device parameter setting requirements:the device is connected as a client mode to our Hanfeng test server. Address: nat1.iotworkshop.com, TCP port: 3006. Step1: Plug in a SIM card that can access the Internet and connect the antenna to the power supply. Then connect the hotspot or network cable of the PC directly to the computer. Then you should check the IP address obtained by the PC.。 Note: The IP address obtained after the PC connects to the AP of the device is 10.10.100.xxx. If the network cable is directly connected to the PC, there are two situations in which the PC obtains the IP address. 1, the device wifi work mode is AP mode, the PC got the IP address is 169.254.xxx.xxx. 2 Device wifi works In STA mode, the PC gets the is 10.10.100.xxx 。 Step 2:Open the browser input device IP address, enter the settings page and then check whether the device is connected to the 4G network, mainly to see if the http://www.iotworkshop.com 6 Copyright © 2013 . All rights reserved device has an IP address, as shown below. If the device's IP address is 0, it means there is no network connection. Disconnect the SIM card after power off. Note: The computer is best to open only one network card. If your computer's IP address is 10.10.100.xxx, enter 10.10.100.254 to enter the web settings interface. If the IP address obtained by the computer is 169.254.xxx.xxx, enter 169.254.173.207 to enter the web page setting interface. The SIM card of this device does not support hot plugging.。 Step 3:Click on the communication settings, select the protocol type and fill in the server address and port number and serial port number. After setting, click the submit button. Note: The HF2421 device has two serial ports, uart1 and uart2, which need to be set corresponding to the serial port number on the device.。 http://www.iotworkshop.com 7 Copyright © 2013 . All rights reserved Step 4 :After setting, restart the device as shown below. Step 5:The PC opens the Serial SecureCRT tool, selects the corresponding port number and baud rate, and displays the interactive window. Step 6:Transparent transmission test. http://www.iotworkshop.com 8 Copyright © 2013 . All rights reserved 5. Transparent test case two:IOTSerivice Tool Configuration The application scenario is the same as the case one. Step 1: Insert a SIM card that can access the Internet and connect the antenna to the power supply. Then, the PC connects the device's hotspot or network cable directly to the PC. Step2 :Open the IOTService tool and the device will appear as shown below.。 Step 3:Double-click the device bar to enter the device status interface and check whether the device is connected to the 4G network. If it is connected, click the edit button to enter the device editing interface. If the device IP address is 0, it indicates that no 4G network is connected, power is off, and the card is inserted or removed. Step 4: After entering the configuration interface, set the network communication parameters. After setting, click OK, as shown in the figure below. http://www.iotworkshop.com 9 Copyright © 2013 . All rights reserved 、 Step 5:Restart Step 6: The PC opens the Serial SecureCRT tool for transparent data transmission test。 http://www.iotworkshop.com 10 Copyright © 2013 . All rights reserved 6. Web page upgrade firmware The device supports online firmware upgrades. Users can upgrade through the web page portal. External web pages and internal web pages (suffix +hide, internal web pages can also be used to upgrade external web pages) can be used.。 HF2421 device latest firmware address: http://www.hi-flying.com/download-center-1/firmware-1/download-item-hf2421-f irmware Step1: Enter the Hanfeng official website to download the latest firmware。 Step 2:Open the browser and enter the device IP address to enter the web page setting interface. Step 3: Click on other to select the firmware Step 4:After selecting the firmware, click Start. The device will restart automatically after success. Step 5: After the device restarts, you can enter the web page again to check the firmware version to determine whether the firmware upgrade is successful. http://www.iotworkshop.com 11 Copyright © 2013 . All rights reserved Appendix 1 For more information, please visit the official website to download more information about industrial control equipment applications. download link: Http://www.hi-flying.com/download-center-1/application-notes-1/download-item -industry-products-application-manual-20180415 http://www.iotworkshop.com 12 Copyright © 2013 . All rights reserved ">
Advertisement