Omron CS1W-CIF31, XW2Z-200P-V User Manual
Advertisement
Advertisement
Cat. No. W417-E1-03
USB-Serial Conversion Cable
User's Manual
USB-Serial Conversion Cable
CS1W-CIF31
User's Manual
Notice:
OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual.
The following conventions are used to indicate and classify precautions in this manual.
Always heed the information provided with them. Failure to heed precautions can result in injury to people or damage to property.
DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING Indicates a potentially hazardous situation which, if not avoided,
Caution could result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury, or property damage.
OMRON Product References
All OMRON products are capitalized in this manual. The word “Unit” is also capitalized when it refers to an OMRON product, regardless of whether or not it appears in the proper name of the product.
The abbreviation “Ch,” which appears in some displays and on some OMRON products, often means “word” and is abbreviated “Wd” in documentation in this sense.
The abbreviation “PLC” means Programmable Controller. “PC” is used, however, in some Programming Device displays to mean Programmable Controller.
Visual Aids
The following headings appear in the left column of the manual to help you locate different types of information.
Note Indicates information of particular interest for efficient and convenient operation of the product.
1,2,3... 1. Indicates lists of one sort or another, such as procedures, checklists, etc.
OMRON, 2003
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of OMRON.
No patent liability is assumed with respect to the use of the information contained herein. Moreover, because OMRON is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Nevertheless, OMRON assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication.
2
TABLE OF CONTENTS
TABLE OF CONTENTS
Notice: ......................................................................................................................... 2
OMRON Product References...................................................................................... 2
Visual Aids................................................................................................................... 2
TABLE OF CONTENTS
........................................................................... 3
About this Manual
.................................................................................... 4
PRECAUTIONS
....................................................................................... 5
Overview and Components
...................................................................... 8
Overview ..................................................................................................................... 8
Appearance and Component Names
.......................................................................... 8
Packing Lists
............................................................................................ 9
D-sub Connector Cable (CS1W-CIF31)...................................................................... 9
Specifications
........................................................................................... 10
Compatible Operating Systems
.................................................................................. 10
Compatible Software Applications
.............................................................................. 10
Compatible PLCs, PTs and Programmable Relay ...................................................... 11
Connection Configurations .......................................................................................... 12
General Specifications ................................................................................................ 13
Dimensions
.............................................................................................. 14
D-sub Connector Cable
............................................................................................... 14
System Configuration
............................................................................... 15
CS/CJ-series PLCs
..................................................................................................... 15
C-series PLCs
............................................................................................................. 17
CVM1 and CV-series PLCs
......................................................................................... 20
PTs (NS and NT Series)
............................................................................................. 21
Programmable Relay (ZEN) ........................................................................................ 21
USB to PLC/PT Connection Tables
......................................................... 22
Connecting with the CS1W-CIF31 (D-sub Connector Cable) ..................................... 22
Application Procedure
.............................................................................. 27
Cable Connections
.................................................................................. 28
Connecting the Cable
.................................................................................................. 28
Installing the Drivers
................................................................................ 29
Uninstalling the Drivers
............................................................................ 33
Connecting Online from the CX-Programmer
.......................................... 34
Using More than One Conversion Cable
................................................. 38
Revision History
....................................................................................... 39
Index
........................................................................................................ 40
3
About this Manual
About this Manual
Thank you for purchasing the CS1W-CIF31 USB-Serial Conversion Cable.
The CS1W-CIF31 USB-Serial Conversion Cable connects an OMRON PLC (or PT) to a personal computer's USB port.
Please read this manual carefully and be sure you understand the information provided before attempting to install or operate the USB-Serial Conversion Cables. Be sure to read the precautions provided in the following section.
Precautions provides general precautions for using the USB-Serial Conversion Cables and related devices.
Overview and Components describes the parts of the USB-Serial Conversion Cables and gives an overview of their application.
Packing Lists shows the various items that come with the USB-Serial Conversion
Cables.
Specifications provides the hardware and software specifications.
Dimensions shows external cable dimensions.
System Configuration shows the application of the USB-Serial Conversion Cables with various models of PLC.
USB to PLC/PT Connection Tables lists the possible combinations of Cables, Units, and ports that can be used.
Application Procedure gives an overview of the steps required to use USB-Serial
Conversion Cables.
DIP Switch Settings and Cable Connections describes switch settings and cable connections.
Installing the Drivers tells how to install the software drivers.
Uninstalling the Drivers tells how to uninstall the software drivers.
Connecting Online from the CX-Programmer tells how to connect to a PLC or PT from a computer running the CX-Programmer.
WARNING Failure to read and understand the information provided in this manual may result in personal injury or death, damage to the product, or product failure. Please read each section in its entirety and be sure you understand the information provided in the section and related sections before attempting any of the procedures or operations given.
4
PRECAUTIONS
PRECAUTIONS
This section provides general precautions for using the USB-Serial Conversion Cable and related devices.
The information contained in this section is important for the safe and reliable application of the USB-Serial Conversion Cable. You must read this section and understand the information contained before attempting to set up or operate a
USB-Serial Conversion Cable and PLC system.
█
Intended Audience
This manual is intended for the following personnel, who must also have knowledge of electrical systems (an electrical engineer or the equivalent).
•Personnel in charge of purchasing FA devices.
•Personnel in charge of designing FA systems.
•Personnel in charge of managing FA systems and facilities.
█
General Precautions
•The user must operate the product according to the performance specifications described in the operation manuals.
•Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems, machines, and equipment that may have a serious influence on lives and property if used improperly.
•This manual provides important information for using the CS1W-CIF31 USB-Serial
Conversion Cable. Be sure to read this manual before attempting to use the
Conversion Cable and keep this manual close at hand for reference during operation.
WARNING It is extremely important that a PLC and all PLC Units be used for the specified purpose and under the specified conditions, especially in applications that can directly or indirectly affect human life. You must consult with your OMRON representative before applying a PLC system to the above mentioned applications.
█
Operating Environment Precautions
Do not use the USB-serial Conversion Cable in the following places:
•Locations subject to strong electromagnetic fields.
•Locations subject to direct sunlight.
•Locations subject to temperatures or humidity outside the range specified in the specifications.
•Locations subject to condensation as the result of severe changes in temperature.
•Locations subject to corrosive or flammable gases.
•Locations subject to excessive dust, or salts, or metal filings.
•Locations subject to exposure to water, oil, or chemicals.
•Locations subject to shock or vibration.
Provide proper shielding when installing in the following locations:
•Locations subject to static electricity or other sources of noise.
•Locations subject to strong electromagnetic fields.
•Locations subject to possible exposure to radiation.
•Locations near power supply lines.
5
PRECAUTIONS
█
Application Precautions
Observe the following precautions when using the USB-Serial Conversion Cable.
•These cables are designed specifically to connect a personal computer to an OMRON
PLC or PT. Do not use them to connect any other devices and do not use a commercially available USB-serial conversion cable in place of these cables. Improper usage of these cables may result in damage to external devices, the PLC, or the PT.
•Do not attempt to disassemble, repair, or modify any Units.
•Touch a grounded metal object to discharge any static electricity before connecting the
Conversion Cable to the PLC's connector, a PLC Connecting Cable, or the personal computer's USB port.
•To avoid malfunctions due to noise, do not route the Conversion Cable parallel or close to a high-tension power line.
•Tighten the D-sub connector screws to a torque of 0.4 N ⋅ m.
•Either turn OFF the power supply to the computer or disconnect the cable from the
USB connector before setting the DIP switch.
•Always lock any connectors that are equipped with locking mechanisms.
•Do not place anything on the cable.
•Do not bend the cable past it's normal bending radius or pull on the cable.
•Touch the Unit only after touching a grounded metal object to release static electricity from your body.
•Disconnect or connect the cable only after confirming that communications are not in progress.
•Do not quickly and repeatedly connect and disconnect the USB connector. Doing so may cause the computer to malfunction.
•It may take some time for the computer to detect the cable after the cable is connected.
This is not a malfunction.
•Do not connect the RS-232C connector on the CS1W-CIF31 Cable (D-sub type) directly to the RS-232C or RS-422/485 connector on the PLC. The cable may malfunction.
•Do not connect this cable to a USB hub; connect it directly to a USB connector on the computer.
The cable may malfunction.
•Do not extend the USB portion of this cable with an extension cable. The cable may malfunction.
•Set the communications port (COM port) number used by the software to the communications port (COM port) number allocated to the Conversion Cable.
Caution Perform wiring so that the power supply wires are not exposed and do not come into contact with any metal parts. Contact with metal parts may cause a fire.
6
PRECAUTIONS
█
EC Directives
●
Applicable Directives
•EMC Directives
•Low Voltage Directive
●
Concepts
• EMC Directives
OMRON devices that comply with EC Directives also conform to the related EMC standards so that they can be more easily built into other devices or the overall machine.
The actual products have been checked for conformity to EMC standards (see the following note). Whether the products conform to the standards in the system used by the customer, however, must be checked by the customer.
EMC-related performance of the OMRON devices that comply with EC Directives will vary depending on the configuration, wiring, and other conditions of the equipment or control panel on which the OMRON devices are installed. The customer must, therefore, perform the final check to confirm that devices and the overall machine conform to EMC standards.
Note: Within the EMC (Electromagnetic Compatibility) standards, the applicable EMS
(Electromagnetic Susceptibility) standard is EN61000-6-2 and the applicable EMI
(Electromagnetic Interference) standard is EN61000-6-4 (10-m regulations.)
• Low Voltage Directive
Always ensure that devices operating at voltages of 50 to 1,000 VAC and 75 to 1,500
VDC meet the required safety standards (EN61131-2).
• Conformance to EC Directives
The CS1W-CIF31 USB-Serial Conversion Cables comply with EC Directives. Observe the following precautions to ensure that the machine or device in which the Conversion
Cable is used complies with EC directives:
1. The CS1W-CIF31 USB-Serial Conversion Cable must be installed within a control panel.
2. Reinforced insulation or double insulation must be used for the DC power supplies providing the communications power supply and I/O power supplies.
3. CS1W-CIF31 USB-Serial Conversion Cables complying with EC Directives also conform to the Common Emission Standard (EN61000-6-4). Radiated emission characteristics (10-m regulations) may vary depending on the configuration of the control panel used, other devices connected to the control panel, wiring, and other conditions. You must therefore confirm that the overall machine or equipment complies with EC Directives.
7
Overview and Components
Overview and Components
Overview
The CS1W-CIF31 USB-Serial Conversion Cable connects an OMRON PLC
(Programmable Controller) or PT (Programmable Terminal) to a personal computer's
USB port. The cable can be used once the required drivers (on the provided CD-ROM) have been installed in the personal computer.
The Conversion Cable can be used with OMRON PLC/PT software, such as the
CX-Programmer, which use the CX-Server or FinsGateway as a communications driver, as well as other OMRON Software, such as the DeviceNet Configurator.
Appearance and Component Names
█
D-sub Connector Cable
●
CS1W-CIF31 (USB Connector to D-sub Connector)
D-Sub 9-pin connector (male)
USB connector
(A plug connector, male)
LED Indicators
Indicator
TD
RD
Color Status
Yellow
Yellow
Flashing
OFF
Description
Data is being sent from the USB-Serial Conversion
Cable.
Data is not being sent from the USB-Serial Conversion
Cable.
Flashing The USB-Serial Conversion Cable is receiving data.
OFF The USB-Serial Conversion Cable is not receiving data.
8
Packing Lists
D-sub Connector Cable (CS1W-CIF31)
Name
CS1W-CIF31
(USB Connector to D-sub Connector
Conversion Cable)
Drivers
(On CD-ROM)
User's Manual (this manual)
(On CD-ROM in PDF format)
Instruction Sheet
Appearance
Packing Lists
9
Specifications
Specifications
Compatible Operating Systems
Windows 98/ME/2000/XP/Vista
Compatible Software Applications
The compatible software applications communicate with the PLC using the CX-Server or FinsGateway. The following software applications use CX-Server or FinsGateway.
Name Communications software
CX-Programmer CX-Server (FinsGateway is used for network communications.)
CX-Simulator FinsGateway
CX-Protocol
CX-Position
CX-Server (FinsGateway is used for network communications.)
FinsGateway
CX-Motion
CX-Process
NS-Designer
PLC Reporter
CX-Server
FinsGateway or CX-Server
FinsGateway
FinsGateway
The following software applications are also compatible.
• DeviceNet Configurator
• NT Support Tool for Windows
• ZEN Support Software Ver. 3.0 or later
• Software applications in CX-One
• Communications Port Limitations with the NT Support Tool
1) Version 4.00 and Earlier Versions
Only communications ports COM1 and COM2 can be used. Always change the communications port allocation for this device to COM1 or COM2 in the Microsoft
Windows Device Manager (see note 1) and specify that port in the NT Support Tool's communications settings. Once the communications port is specified correctly in the
Windows Device Manager and the NT Support Tool's communications settings, data such as screen data can be downloaded to the PT or uploaded from the PT through the
USB-Serial Conversion Cable.
Note: In most personal computers, COM1 is allocated to the RS-232C port and communications port COM2 can be allocated to the Conversion Cable. Refer to
Changing the Allocated Communications Port on page 36 for details on changing the communications port. Furthermore, if there is another driver using the allocated port, that driver must be uninstalled.
2) Version 4.60E and Later Versions
Any communications port between COM 1 and COM8 can be used. Check the NT
Support Tool's communications settings and verify that the communications port allocated to the Conversion Cable is also specified in the NT Support Tool.
10
Specifications
• Limitations when Using the NT Support Tool's System Installer
1) Windows 98 and Windows Me
The system program cannot be downloaded to the PT through the USB-Serial
Conversion Cable.
2) Windows 2000, Windows XP, and Windows Vista
Only communications ports COM1 and COM2 can be used. Always change the communications port allocation for this device to COM1 or COM2 in the Microsoft
Windows Device Manager (see note 1) and specify that port in the NT Support Tool's communications settings. Once the communications port is specified correctly in the
Windows Device Manager and the NT Support Tool's communications settings, the system program can be downloaded to the PT through the USB-Serial Conversion
Cable.
Note: In most personal computers, COM1 is allocated to the RS-232C port and communications port COM2 can be allocated to the Conversion Cable. Refer to Changing the Allocated Communications Port on page 36 for details on changing the communications port. Furthermore, if there is another driver using the allocated port, that driver must be uninstalled.
Compatible PLCs, PTs and Programmable Relay
The following OMRON PLCs, PTs and Programmable Relay are supported by the compatible software applications.
• PLCs
CS/CJ-series, C-series (see note 1), and CVM1/CV-series
• PT
NS-series and NT-series
• Programmable Relay
ZEN (see note 2)
Note 1. The following C-series PLCs are supported: C200HS, C200HX/HG/HE, C200H, C1000H,
C2000H, CQM1, CPM1, CPM1A, CPM2A, SRM1, CQM1H, and CPM2C.
Note 2. The ZEN Programmable Relay is supported only if ZEN Support Software Ver. 3.0 or later is used.
11
Specifications
Connection Configurations
Note
The following table shows the connection configurations that can be used to connect an
OMRON PLC (or PT) to a personal computer's USB port.
USB-Serial Conversion Required adapters or cables
Conversion
Cable
CS1W-CIF31
(D-sub version)
Cable's serial connector
D-sub 9-pin male
•CS1W-CN226/626
(Programming Device Connecting Cable for a
CS/CJ-series peripheral port and personal computer)
•XW2Z-200/500S-CV or XW2Z-200/500S-V
(Programming Device Connecting Cable for an RS-232C port and personal computer)
+
•CS1W-CN118
(RS-232C to CS/CJ-series peripheral port
Conversion Cable)
•CQM1-CIF02
(Programming Device Connecting Cable for a
C-series peripheral port and personal computer)
+
•CS1W-CN114
(C-series peripheral port to CS/CJ-series peripheral port Conversion Cable)
•CQM1-CIF02
(Programming Device Connecting Cable for a
C-series peripheral port and personal computer)
•RS-232C 9-pin to 25-pin adapter
+
•CV500-CIF01
(Programming Device Connecting Cable for a
CV-series peripheral port and PC98-type personal computer)
•XW2Z-200/500S-CV or XW2Z-200/500S-V
(Programming Device Connecting Cable for an RS-232C port and personal computer)
ZEN-CIF01
(Personal Computer Connecting Cable)
Compatible
PLC or PT connector
CS/CJ-series peripheral port
C-series peripheral port
CV-series peripheral port
RS-232C port
(D-sub 9-pin)
Personal
Computer
Connecting port
Compatible PLCs and PTs
CS/CJ-series,
CQM1H, and
CPM2C
C200HS,
C200HX/HG/HE,
CQM1, CPM1,
CPM1A, CPM2A, and SRM1
CVM1/CV-series
PLCs (CPU Unit or Serial
Communication
Unit/Board connection) or
PTs
ZEN
The USB-Serial Conversion Cables are for connections between a USB port and an
OMRON PLC/PT only. In particular, the CS1W-CIF31 Cable can be used only with compatible OMRON software applications even though it has a standard D-sub 9-pin connector on one end.
12
Specifications
General Specifications
USB Interface rating
DTE speed
Conforms to USB Specification 1.1
115.2 kbps
Connector specifications
Power supply
Current consumption
Operating environment
Weight
Ambient temperature
Ambient humidity
Atmosphere
Computer end USB (type A plug, male)
PLC end RS-232C (D-sub 9-pin, male)
Bus power (5 VDC power from upstream)
35 mA
0 to 55 ° C
10% to 90% humidity (with no condensation)
No corrosive gases
50 g
13
Dimensions
Dimensions
D-sub Connector Cable
█
CS1W-CIF31
72.4
6
500 (46) (11.75)
14
System Configuration
System Configuration
CS/CJ-series PLCs
●
Connecting to the Peripheral Port
• Using a CS1W-CN226/626 Cable
USB type A plug, male
CS1W-CIF31
D-sub Connector
(9-pin male)
CS/CJ-series PLC connection
Customizable Counter Unit connection
CS/CJ-series peripheral connector
D-sub Connector
(9-pin female)
Peripheral port
Recommended cable:
CS1W-CN226/626
• Using a CQM1-CIF02 Cable
USB type A plug, male
CS1W-CIF31
D-sub Connector
(9-pin male)
CS/CJ-series PLC connection (see note)
D-sub Connector
(9-pin female)
C-series peripheral connector
CS/CJ-series peripheral connector
Peripheral port
Recommended cable:
CQM1-CIF02
CS1W-CN114
Note: With a CS/CJ-series PLC, the connection must be a host link connection.
15
System Configuration
• Using a XW2Z-200S-CV/500S-CV or XW2Z-200S-V/500S-V Cable for an RS-232C
Connection
USB type A plug, male
CS1W-CIF31
D-sub Connector
(9-pin male)
D-sub Connector
(9-pin female)
CS/CJ-series PLC connection
Customizable Counter Unit connection
D-sub Connector (9-pin male)
Peripheral port
XW2Z-200S-CV/500S-CV or
D-sub Connector
XW2Z-200S-V/500S-V (See note.)
(9-pin female)
CS/CJ-series peripheral connector
CS1W-CN118
Note: With a CS/CJ-series PLC, the connection must be a host link connection.
●
Connecting to the RS-232C Port
• Using a XW2Z-200S-CV/500S-CV or XW2Z-200S-V/500S-V Cable for an RS-232C
Connection
USB type A plug, male
CS1W-CIF31
D-sub Connector
(9-pin male)
CS/CJ-series PLC connection
D-sub Connector
(9-pin male)
D-sub Connector
(9-pin female)
RS-232C port
D-sub Connector
(9-pin female)
Recommended cable:
XW2Z-200S-CV/500S-CV or
XW2Z-200S-V/500S-V (See note.)
Note: With a CS/CJ-series PLC, the connection must be a host link connection.
16
System Configuration
C-series PLCs
█
C200HS, C200HX/HG/HE, C200H, C1000H, C2000H, CQM1, CPM1, CPM1A,
CPM2A, or SRM1
• Connecting to the Peripheral Port
Using a CQM1-CIF02 Cable
USB type A plug, male
CS1W-CIF31
D-sub Connector
(9-pin male)
D-sub Connector
(9-pin female)
C-series PLC connection
C-series peripheral connector
Peripheral port
Recommended cable:
CQM1-CIF02
• Connecting to the RS-232C Port
Using a XW2Z-200S-CV/500S-CV or XW2Z-200S-V/500S-V Cable for an RS-232C
Connection
USB type A plug, male
CS1W-CIF31
D-sub Connector
(9-pin male)
C-series PLC connection
D-sub Connector
(9-pin male)
D-sub Connector
(9-pin female)
RS-232C port
D-sub Connector
(9-pin female)
Recommended cable:
XW2Z-200S-CV/500S-CV or
XW2Z-200S-V/500S-V
17
System Configuration
█
CQM1H and CPM2C PLCs
• Connecting to the Peripheral Port
Using a CS1W-CN226/626 Cable
USB type A plug, male
CS1W-CIF31
D-sub Connector
(9-pin male)
CQM1H PLC connection
CPM2C PLC connection
CS/CJ-series peripheral connector
D-sub Connector
(9-pin female)
Peripheral port
Recommended cable:
CS1W-CN226/626
Using a CQM1-CIF02 Cable
USB type A plug, male
USB type A plug, male
CS1W-CIF31
D-sub Connector
(9-pin male)
D-sub Connector
(9-pin female)
CQM1H PLC connection
CPM2C PLC connection
C-series peripheral connector
CS/CJ-series peripheral connector
Peripheral port
Recommended cable:
CQM1-CIF02
CS1W-CN114
Note: With a CS/CJ-series PLC, the connection must be a host link connection.
18
System Configuration
Using a XW2Z-200S-CV/500S-CV or XW2Z-200S-V/500S-V Cable for an RS-232C
Connection
USB type A plug, male
CS1W-CIF31
D-sub Connector
(9-pin male)
CQM1H PLC connection
CPM2C PLC connection
D-sub Connector
D-sub Connector (9-pin male)
(9-pin female)
Peripheral port
XW2Z-200S-CV/500S-CV or
XW2Z-200S-V/500S-V
D-sub Connector
CS/CJ-series peripheral connector
(9-pin female)
(See note.)
CS1W-CN118
Note: With a CS/CJ-series PLC, the connection must be a host link connection.
• Connecting to the RS-232C Port
Using a XW2Z-200S-CV/500S-CV or XW2Z-200S-V/500S-V Cable for an RS-232C
Connection
USB type A plug, male
CS1W-CIF31 CQM1H PLC connection
D-sub Connector
CPM2C PLC connection
(9-pin male) D-sub Connector
(9-pin male)
D-sub Connector
(9-pin female)
RS-232C port
D-sub Connector
(9-pin female)
XW2Z-200S-CV/500S-CV or
XW2Z-200S-V/500S-V
(See note.)
Note: With a CS/CJ-series PLC, the connection must be a host link connection.
19
System Configuration
CVM1 and CV-series PLCs
●
Connecting to the Peripheral Port
• Using a CV500-CIF01 Cable
USB type A plug, male
CS1W-CIF31
D-sub Connector
(9-pin male)
D-sub 25-pin (female) to
9-pin (female) Adapter
CVM1/CV-series PLC connection
D-sub Connector
(25-pin male)
CV-series peripheral connector
Peripheral port
Recommended cable:
CV500-CIF01
●
Connecting to the RS-232C Port
• Using a XW2Z-200S-V/500S-V Cable
USB type A plug, male
CS1W-CIF31
D-sub Connector
(9-pin male)
CVM1/CV-series PLC connection
D-sub Connector (9-pin male)
D-sub Connector
(9-pin female)
RS-232C port
D-sub Connector
(9-pin female)
Recommended cable:
XW2Z-200S-V/500S-V
20
PTs (NS and NT Series)
●
Connecting to the RS-232C Port
• Using a XW2Z-S002 Cable
USB type A plug, male
CS1W-CIF31
D-sub Connector
(9-pin male)
D-sub
D-sub Connector
Connector
(9-pin male)
(9-pin female)
PT connection
XW2Z-S002
Programmable Relay (ZEN)
RS-232C port
System Configuration
USB type A plug, male
CS1W-CIF31
D-sub Connector
(9-pin male)
D-sub Connector
(9-pin female)
Personal Computer
Connector
ZEN
Personal Computer
Connecting Cable
ZEN-CIF01
Personal Computer
Connecting port
21
USB to PLC/PT Connection Tables
USB to PLC/PT Connection Tables
Connecting with the CS1W-CIF31 (D-sub Connector Cable)
Computer CS1W-CIF31
Cable 2
(when necessary)
CS1W-N226/626 Programming
Device Connecting Cable for a
CS/CJ-series peripheral port
CS1W-CN114
C-series peripheral port to CS/CJ-series peripheral port Conversion Cable
CS1W-CIF31 USB
Conversion Cable
OR
CQM1H-CIF02 Programming
Device Connecting Cable for a
C-series peripheral port +
CS1W-CN118
RS-232C to CS/CJ-series peripheral port Conversion Cable
+
OR
XW2Z@@@ Programming Device
Connecting Cable for RS-232C
PLC
█
CS/CJ-series Units
●
CS/CJ-series CPU Units
USB
Conversion
Cable
Model
CS1W-CIF31
Connector
D-sub 9-pin, female
D-sub 9-pin, female female female
D-sub 9-pin,
D-sub 9-pin,
D-sub 9-pin, female
D-sub 9-pin, female
Cable 1
Model
CS1W-CN226/626
(Length: 2 or 6 m)
CQM1-CIF02
(Length: 3.3 m)
XW2Z-200S-CV
/500S-CV
(Length: 2 or 5 m)
XW2Z-200S-V
/500S-V
(Length: 2 or 5 m)
XW2Z-200S-CV
/500S-CV
(Length: 2 or 5 m)
XW2Z-200S-V
/500S-V
(Length: 2 or 5 m)
Connector Connector
CS/CJ-series peripheral
C-series peripheral
D-sub 9-pin, male male
D-sub 9-pin,
RS-232C
D-sub 9-pin, male
RS-232C
D-sub 9-pin, male
C-series peripheral female
D-sub 9-pin,
D-sub 9-pin, female
Cable 2
Model
Not necessary
CS1W-CN114
(Length: 5 cm)
CS1W-CN118
(Length: 0.1 m)
CS1W-CN118
(Length: 0.1 m)
Not necessary
Not necessary
Connector
CS/CJ-series peripheral
CS/CJ-series peripheral
CS/CJ-series peripheral
Unit's port
CS/CJ-series peripheral
Serial communications mode
(Network type)
Peripheral bus
(Toolbus) or Host link (SYSWAY)
Host link
(SYSWAY)
Peripheral bus
(Toolbus) or Host link (SYSWAY)
Host link
(SYSWAY)
RS-232C
D-sub 9-pin, female
Peripheral bus
(Toolbus) or Host link (SYSWAY)
Host link
(SYSWAY)
22
USB to PLC/PT Connection Tables
●
CS/CJ-series Serial Communications Board or Unit
USB
Conversion
Cable
Model
CS1W-CIF31
Connector
D-sub 9-pin, female
D-sub 9-pin, female
Cable 1
Model
XW2Z-200S-CV
/500S-CV
(Length: 2 or 5 m)
XW2Z-200S-V
/500S-V
(Length: 2 or 5 m)
Connector Connector
RS-232C
D-sub 9-pin, male
RS-232C
D-sub 9-pin, male
●
Customizable Counter Unit
USB
Conversion
Cable
Model
CS1W-CIF31
Connector
D-sub 9-pin, female
D-sub 9-pin, female
Cable 1
Model
CS1W-CN226/626
(Length: 2 or 6 m)
XW2Z-200S-V
/500S-V
(Length: 2 or 5 m)
█
C-series Units
Cable 2
Model
Not necessary
Connector
Not necessary
Unit's port
RS-232C
D-sub 9-pin, female
Serial communications mode
(Network type)
Host link
(SYSWAY)
Cable 2
Connector Connector
CS/CJ-series peripheral
D-sub 9-pin, male
D-sub 9-pin, female
Model
Not necessary
CS1W-CN118
(Length: 0.1 m)
Connector
CS/CJ-series peripheral
Unit's port
CS/CJ-series peripheral
Serial communications mode
(Network type)
Peripheral bus
(Toolbus)
Peripheral bus
(Toolbus)
Note: In this table, the C-series refers to the C200HS, C200HX/HG/HE, C200H, C1000H,
C2000H, CQM1, CPM1, CPM1A, CPM2A, SRM1, CQM1H, and CPM2C.
●
C200HS, C200HX/HG/HE, CQM1, CPM1, CPM1A, CPM2A, and SRM1
USB
Conversion
Cable
Model
CS1W-CIF31
Connector
D-sub 9-pin, female
Cable 1
Model
CQM1-CIF02
(Length: 3.3 m)
Connector Connector
C-series peripheral
Cable 2
Model
Not necessary
Connector
Unit's port
C-series peripheral
Serial communications mode
(Network type)
Peripheral bus
(Toolbus) or Host link (SYSWAY)
(See note.)
Host link
(SYSWAY)
D-sub 9-pin, female
D-sub 9-pin, female
XW2Z-200S-CV
/500S-CV
(Length: 2 or 5 m)
XW2Z-200S-V
/500S-V
(Length: 2 or 5 m)
D-sub 9-pin, male
D-sub 9-pin, male
Not necessary
Not necessary
RS-232C
D-sub 9-pin, female
Note: The host link mode can be used in all of these PLCs, but the peripheral bus mode cannot be used in CPM2 @ PLCs that have a 9 as the 4 th
digit of the lot number. (The lot number may be 4 or 5 digits long.)
●
C200H, C1000H, and C2000H CPU Units
USB
Conversion
Cable
Model Connector
CS1W-CIF31 D-sub 9-pin, female
Cable 1
Model
CQM1-CIF02
(Length: 3.3 m)
Connector
C-series peripheral
Connector
C-series peripheral
Cable 2
Model
C200H-IP007
Unit's port
Connector
Built-in peripheral port
Serial communications mode
(Network type)
Host link
(SYSWAY)
23
USB to PLC/PT Connection Tables
●
CQM1H CPU Units
USB
Conversion
Cable
Model
CS1W-CIF31
Connector
D-sub 9-pin, female
Cable 1
Model
CS1W-CN226/626
(Length: 2 or 6 m)
D-sub 9-pin, female
D-sub 9-pin, female
D-sub 9-pin, female
D-sub 9-pin, female
D-sub 9-pin, female
CQM1-CIF02
(Length: 3.3 m)
XW2Z-200S-CV
/500S-CV
(Length: 2 or 5 m)
XW2Z-200S-V
/500S-V
(Length: 2 or 5 m)
XW2Z-200S-CV
/500S-CV
(Length: 2 or 5 m)
XW2Z-200S-V
/500S-V
(Length: 2 or 5 m)
●
CPM2C
Connector Connector
CS/CJ-series peripheral
C-series peripheral
D-sub 9-pin, male
C-series peripheral
D-sub 9-pin, female
Cable 2
Model
Not necessary
CS1W-CN114
(Length: 5 cm)
CS1W-CN118
(Length: 0.1 m)
Connector
CS/CJ-series peripheral
CS/CJ-series peripheral
Unit's port
CS/CJ-series peripheral
Serial communications mode
(Network type)
Peripheral bus
(Toolbus) or Host link (SYSWAY)
D-sub 9-pin, male
D-sub 9-pin, male
D-sub 9-pin, male
D-sub 9-pin, female
CS1W-CN118
(Length: 0.1 m)
Not necessary
Not necessary
CS/CJ-series peripheral
RS-232C
D-sub 9-pin, female
Host link
(SYSWAY)
Host link
(SYSWAY)
USB
Conversion
Cable
Model
CS1W-CIF31
Connector
D-sub 9-pin, female
Cable 1
Model
CQM1-CIF02
(Length: 3.3 m)
Connector Connector
C-series peripheral
C-series peripheral
Cable 2
Model
CS1W-CN114
(Length: 5 cm)
D-sub 9-pin, female
D-sub 9-pin, female
CPM2C-CN111
(RS-232C port connector)
CS1W-CN118
(Length: 0.1 m)
Connector
CS/CJ-series peripheral
Unit's port
CS/CJ-series peripheral
Serial communications mode
(Network type)
Peripheral bus
(Toolbus) or Host link (SYSWAY)
(See note 1.)
D-sub 9-pin, female
CQM1-CIF02
(Length: 3.3 m)
D-sub 9-pin, female
D-sub 9-pin, female
D-sub 9-pin, female
D-sub 9-pin, female
D-sub 9-pin, female
CS1W-CN226/626
(Length: 2 or 6 m)
(See note 2.)
XW2Z-200S-CV
/500S-CV
(Length: 2 or 5 m)
XW2Z-200S-CV
/500S-CV
(Length: 2 or 5 m)
XW2Z-200S-V
/500S-V
(Length: 2 or 5 m)
XW2Z-200S-V
/500S-V
(Length: 2 or 5 m)
C-series peripheral
CS/CJ-series peripheral
D-sub 9-pin, male
D-sub 9-pin, male
D-sub 9-pin, male
D-sub 9-pin, male
C-series peripheral
CPM2C-CN111
(Peripheral port connector)
Not necessary
CS/CJ-series peripheral
D-sub 9-pin, female
CS1W-CN118
(Length: 0.1 m)
D-sub 9-pin, female
CPM2C-CN111
(RS-232C port connector)
CS/CJ-series peripheral
CS/CJ-series peripheral
CS/CJ-series peripheral
CS/CJ-series peripheral
RS-232C
D-sub 9-pin, female
Host link
(SYSWAY)
Host link
(SYSWAY)
Note 1: The host link mode can be used in all of these PLCs, but the peripheral bus mode cannot be used in CPM2 @ PLCs that have a 9 as the 4 th
digit of the lot number. (The lot number may be 4 or 5 digits long.)
Note 2: Only host link mode can be used.
24
USB to PLC/PT Connection Tables
●
C-series Host Link Unit (C200H-LK201-V1 or C120-LK201-V1)
Note: The Host Link Unit cannot be used to connect a Programming Device (such as the
CX-Programmer) to a C200HX/HG/HE with the "-ZE" suffix at the end of the model number.
USB
Conversion
Cable
Model Connector
CS1W-CIF31 D-sub 9-pin, female
Cable 1
Model
XW2Z-200P-V
/500P-V
(Length: 2 or 5 m)
Connector Connector
D-sub 25-pin, male
Cable 2
Model
Not necessary
Connector
Unit's port
RS-232C
D-sub
25-pin, female
Serial communications mode
(Network type)
Host link
(SYSWAY)
●
C-series Communications Board (C200HX/HG/HE PLCs Only)
USB
Conversion
Cable
Model
CS1W-CIF31
Connector
D-sub 9-pin, female
D-sub 9-pin, female
Cable 1
Model
XW2Z-200S-CV
/500S-CV
(Length: 2 or 5 m)
XW2Z-200S-V
/500S-V
(Length: 2 or 5 m)
Connector Connector
D-sub 9-pin, male
D-sub 9-pin, male
Cable 2
Model
Not necessary
Not necessary
●
C200H, C1000H, and C2000H Host Link Units
Connector
Unit's port
RS-232C
D-sub
9-pin, female
Serial communications mode
(Network type)
Host link
(SYSWAY)
Note: The C500-LK203 and C500-LK 201-V1 Host Link Units can be used with the C1000H and
C2000H. The C200H-LK201-V1 and C120-LK201-V1 Host Link Units can be used with the
C200H.
USB
Conversion
Cable
Model Connector
CS1W-CIF31 D-sub 9-pin, female
Cable 1
Model
XW2Z-200P-V
/500P-V
(Length: 2 or 5 m)
Connector Connector
D-sub 25-pin, male
Cable 2
Model
Not necessary
Connector
Unit's port
RS-232C
D-sub
25-pin, female
Serial communications mode
(Network type)
Host link
(SYSWAY)
●
CQM1H Serial Communication Board
Cable 2 USB
Conversion
Cable
Model
CS1W-CIF31
Connector
D-sub 9-pin, female
D-sub 9-pin, female
Cable 1
Model
XW2Z-200S-CV
/500S-CV
(Length: 2 or 5 m)
XW2Z-200S-V
/500S-V
(Length: 2 or 5 m)
Connector Connector
D-sub 9-pin, male
D-sub 9-pin, male
Model
Not necessary
Connector
Not necessary
Unit's port
RS-232C
D-sub
9-pin, female
Serial communications mode
(Network type)
Host link
(SYSWAY)
25
USB to PLC/PT Connection Tables
█
CVM1 and CV-series
●
CVM1 and CV-series CPU Units
USB
Conversion
Cable
Model
CS1W-CIF31
Connector
D-sub 9-pin, female
D-sub 9-pin, female
Cable 1 Cable 2
Model
D-sub 25-pin (female) to D-sub 9-pin
(female) adapter
XW2Z-200S-V
/500S-V
(Length: 2 or 5 m)
Connector Connector
D-sub 25-pin, male
D-sub 25-pin, female
Model
CV500-CIF01
(Length: 6 m)
D-sub 9-pin, male
Not necessary
Connector
CV-series peripheral
Unit's port
CV-series peripheral
Serial communications mode
(Network type)
Peripheral bus
(Toolbus)
RS-232C
D-sub
9-pin, female
Host link
(SYSWAY)
●
CVM1 and CV-series Host Link Units
• CV500-LK201 (Port 1, Full-duplex mode)
USB
Conversion
Cable
Model Connector
CS1W-CIF31 D-sub 9-pin, female
Cable 1
Model
XW2Z-200P-V
/500P-V
(Length: 2 or 5 m)
Connector Connector
D-sub 25-pin, male
Cable 2
Model
Not necessary
Connector
Unit's port
RS-232C
D-sub
25-pin, female
Serial communications mode
(Network type)
Host link
(SYSWAY)
• CV500-LK201 (Port 2, Full-duplex mode)
USB
Conversion
Cable
Model Connector
CS1W-CIF31 D-sub 9-pin, female
Cable 1
Model
XW2Z-200S-V
/500S-V
(Length: 2 or 5 m)
Connector Connector
D-sub 9-pin, male
Cable 2
Model
Not necessary
Connector
Unit's port
RS-232C
D-sub
9-pin, female
Serial communications mode
(Network type)
Host link
(SYSWAY)
█
PTs (NS or NT Series)
USB
Conversion
Cable
Model Connector
CS1W-CIF31 D-sub 9-pin, female
Cable 1
Model
XW2Z-S002
(Length: 2 m)
Connector Connector
D-sub 9-pin, male
Cable 2
Model
Not necessary
Connector
Unit's port
RS-232C
D-sub
9-pin, female
Serial communications mode
(Network type)
Host link
(SYSWAY)
█
Programmable Relay (ZEN)
USB
Conversion
Cable
Model Connector
CS1W-CIF31 D-sub 9-pin, female
Cable 1
Model
ZEN-CIF01
(Length: 2 m)
Connector Connector
Personal
Computer
Connector
Cable 2
Model
Not necessary
Connector
Unit's port
Personal
Computer port
-
Serial communications mode
(Network type)
26
Application Procedure
Application Procedure
Note
This section explains how to connect a PLC CPU Unit to a personal computer with a
USB-Serial Conversion Cable. Use the procedure below when connecting a PLC CPU
Unit and personal computer.
The Conversion Cable uses one of the computer's COM ports for communications.
When communicating with a PLC through a Conversion Cable, set the communications port (COM port) number used by the software to the communications port (COM port) number allocated to the Conversion Cable.
1. Connect the Cable(s).
Connect the Conversion Cable to the computer's USB port and the CPU Unit's peripheral port or RS-232C port.
For details, refer to Connecting the Cable on page 28.
2. Install the communications driver.
The Conversion Cable's communications driver must be installed in the computer in order for the computer to use the Conversion Cable.
For details, refer to Installing the Driver on page 29.
3. Turn ON the PLC's power.
Turn ON the PLC's power supply.
4. Make an online connection to the CPU Unit through the computer software (when using the CX-Programmer.)
Select the COM port in the CPU Unit from the CX-Programmer and connect online.
For details, refer to Connecting Online from the CX-Programmer on page 34.
More than one USB-Serial Conversion Cable can be used at a time, so a single personal computer can be connected to several PLCs/PTs through two or more COM ports.
When more than one Conversion Cable is being used, connect the second and later
Cables after the first Cable has been connected.
The communications driver is automatically installed for the second and later Cables, so it is not necessary to install the driver a second time. Each Cable must have its own unique COM port number. Allocate a different COM port to each Cable.
27
Cable Connections
Cable Connections
Connecting the Cable
Connect the computer and CPU Unit with one of the cable configurations shown in the
USB to PLC/PT Connection Tables on page 22.
28
Installing the Drivers
Installing the Drivers
When the USB-Serial Conversion Cable is connected to the computer, the operating system (OS) will recognize the Cable as a new device. At this point, the driver can be installed with the wizard.
The actual driver installation method depends on the OS being used. Windows 2000 is used in the examples in this section.
Note The USB-Serial Conversion Cables are compatible with Windows XP.
When you install the Conversion Cable's driver, a warning message will appear indicating that the driver software has not passed Windows Logo testing, but click
Continue Anyway to proceed with the installation. We have thoroughly tested the driver on Windows XP and verified the it operates properly.
The driver will not be installed properly if the installation process is cancelled before completion. Normal communications may not be possible if the driver is not installed properly. If the driver is not installed properly, uninstall it (refer to page 33) and then reinstall it correctly.
Note The USB-Serial Conversion Cables are compatible with Windows Vista.
When you install the Conversion Cable's driver, a warning message will appear indicating that Windows can’t verify the publisher of this driver software, but click
Continue Anyway to proceed with the installation. We have thoroughly tested the driver on Windows Vista and verified that it operates properly.
The driver will not be installed properly if the installation process is cancelled before completion. Normal communications may not be possible if the driver is not installed properly. If the driver is not installed properly, uninstall it (refer to page 33) and then reinstall it correctly.
1. The following window will be displayed.
2. The following window will be displayed. Click the Next button.
The following window will be displayed.
29
Installing the Drivers
3. Select Search for a suitable driver for my device (recommended) and click the Next button.
The following window will be displayed.
Select Specify a location and click the Next button.
30
The following window will be displayed.
4. Insert the CD-ROM containing the driver (the CD-ROM is in the same package as the Conversion Cable) into the computer's CD-ROM drive. Click the Browse button, select the ftdibus.inf
file, from the following directory of the CD-ROM and click the
OK button.
Windows2000/XP/Vista: win2000_XP
Windows98/Me: win98_Me
If the window's Copy manufacturer's files from field shows the correct folder, click the
OK button.
5. The following window will be displayed. Click the Next button to start the installing the driver.
Installing the Drivers
6. The following window will be displayed if the driver was installed properly. Click the
Finish button.
7. When the button is clicked in step 6, the following window will be displayed for installation of the USB Serial Port driver.
Follow the same procedure in steps 1 through 7 to install the USB Serial Port driver.
(Driver installation is completed after installation of the USB Serial Port driver.)
8. Verify that the drivers were installed properly with the Windows Device Manager, as shown in the following diagram. To access the Device Manager, open the Control
Panel , open the System folder, click the Hardware tab, and click the Device
Manager button.
31
Installing the Drivers
Verify that these two devices appear in the
Device Manager.
32
Uninstalling the Drivers
Uninstalling the Drivers
Use the following procedure to delete (uninstall) the drivers for the USB-Serial
Conversion Cable.
1. Disconnect the Conversion Cable from the computer.
2. Select Add/Remove Programs from the Control Panel .
3. Select OMRON USB-to-Serial Converter Drivers and click the Delete button.
The following window will be displayed.
4. Click the Continue button.
When the drivers have been successfully deleted, the message Uninstall complete, press Finish to exit will be displayed.
5. Click the Finish button.
This completes the deletion (uninstallation) of the Conversion Cable's drivers.
33
Connecting Online from the CX-Programmer
Connecting Online from the CX-Programmer
The USB-Serial Conversion Cable uses one of the computer's COM ports to communicate. The communications port (COM port) allocated to the Conversion Cable must be selected with the CX-Programmer in order to connect online to a PLC or PT.
Note: It may take some time for the computer to detect the cable after the cable is connected. This is not a malfunction.
█
Selecting the Cable's COM Port in CX-Programmer
Use the following procedure to select the COM port used by the Conversion Cable.
1. Display the Change PLC dialog box.
2. Click the Settings button in the Network Type area. Select the desired type of network.
The Network Settings dialog box will be displayed.
3. Click the Driver tab in the Network Settings dialog box.
34
Connecting Online from the CX-Programmer
4. Locate the setting and select the COM port being used by the Conversion
Cable.
Note If you fail to connect with this USB Cable, turn OFF auto baud rate detection if it is being used by your software. With the CX-Programmer, auto baud rate detection can be turned OFF by clearing the selection for it on the Network Settings dialog box.
█
Verifying the Allocated Communications Port
The communications port (COM port) being used by the Conversion Cable can be verified with the following procedure. The actual verification procedure depends on the operating system. This example shows the procedure for Windows 2000.
1. Open the Control Panel , open the System folder, and click the Hardware tab.
2. Click the Device Manager button.
3. Click the + symbol to the left of the Ports (COM & LPT) device icon to display the contents of that folder. Verify that there is an entry for the OMRON CS1W-CIF3 *
USB Serial Port (COM
@
) device.
A communications port name will appear in parentheses. This is the communications port being used by the Conversion Cable.
35
Connecting Online from the CX-Programmer
█
Changing the Allocated Communications Port
Note
The communications port (COM port) being used by the Conversion Cable can be changed with the following procedure. The actual change procedure depends on the operating system. This example shows the procedure for Windows 2000.
If the new COM port is being used by another driver, that driver must be uninstalled.
1. Double-click OMRON CS1W-CIF3* USB Serial Port (COM
@
) in the Device Manager window.
36
2. Click the Port Settings tab.
Connecting Online from the CX-Programmer
3. Click the Advanced button. The following window will be displayed.
4. Select the new COM port number from the COM Port Number list.
5. Click the OK button to change the COM port used by the Conversion Cable.
37
Using More than One Conversion Cable
Using More than One Conversion Cable
The operating system recognizes USB-Serial Conversion Cables individually.
If a second Conversion Cable is connected after the driver has been installed, driver installation will be requested again. Install the driver from the CD-ROM again.
If you do not own the CD-ROM and will use more than one Conversion Cable, copy the win2000_XP folder from the CD-ROM to a folder on your hard disk, and select this folder.
Note: Use the following directory for Windows 98 or Me: Win98_Me
1. Copy the win2000_XP folder from the CD-ROM to your hard disk (the CD-ROM is in the same package as the Conversion Cable).
2. The following window will be displayed.
Select Install from a list or specific location (Advanced) and click the Next button.
38
3. Click the Browse button next to the Include this location in the search field, select the win2000_XP folder copied from CD-ROM onto your hard disk, and click the Next button.
Revision History
Revision History
A manual revision code appears as a suffix to the catalog number on the front cover of the manual.
Cat. No. W417-E1-03
Revision code
The following table outlines the changes made to the manual during each revision. Page numbers refer to the previous version.
Revision code Date Revised content
01 February 2003 Original production
02 October : Changed EMI standard number of EC Directives.
Page 30 : Changed the reference directory for the driver file.
Page 37 : Add section on using more than one Conversion Cable.
03 July Changed the compatible operating systems.
Page 29: Changed information on installing the drivers.
39
Index
Index
C
communications port changing
............................................................................................................. 36 verifying .............................................................................................................. 35 component names .......................................................................................................... 8 configuration, PLC/PT connections
C200HS, C200HX/HG/HE, C200H, C1000H/2000H, CQM1, CPM1, CPM1A,
CPM2A, and SRM1............................................................................................ 17
CQM1H, CPM2C
................................................................................................ 18
CS/CJ-series PLCs
............................................................................................ 15
C-series PLCs
.................................................................................................... 17
CVM1 and CV-series PLCs ............................................................................... 20
NS-series and NT-series PTs
............................................................................ 21
Programmable Relay (ZEN)............................................................................... 21
CX-Programmer communications port .......................................................................................... 34
D
dimensions
................................................................................................................... 14 drivers installing ............................................................................................................. 29 uninstalling
................................................................................................... 33, 38
O
operating system, applicable
........................................................................................ 10 overview
......................................................................................................................... 8
P
PLCs, applicable
.......................................................................................................... 11
PTs, applicable
............................................................................................................. 11
S
software, applicable
...................................................................................................... 10
40
Terms and Conditions of Sale
1.
Offer; Acceptance. These terms and conditions (these "Terms") are deemed part of all quotes, agreements, purchase orders, acknowledgments, price lists, catalogs, manuals, brochures and other documents, whether electronic or in writing, relating to the sale of products or services (collectively, the "Products") by Omron Electronics LLC and its subsidiary companies (“Omron”). Omron objects to any terms or conditions proposed in Buyer’s purchase order or other documents which are inconsistent with, or in addition to, these Terms.
2.
Prices; Payment Terms. All prices stated are current, subject to change without notice by Omron. Omron reserves the right to increase or decrease prices on any unshipped portions of outstanding orders. Payments for Products are due net 30 days unless otherwise stated in the invoice.
3.
Discounts. Cash discounts, if any, will apply only on the net amount of invoices sent to Buyer after deducting transportation charges, taxes and duties, and will be allowed only if (i) the invoice is paid according to Omron’s payment terms and (ii) Buyer has no past due amounts.
4.
Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or the maximum legal rate, whichever is less, on any balance not paid within the stated terms.
5.
Orders. Omron will accept no order less than $200 net billing.
6.
Governmental Approvals. Buyer shall be responsible for, and shall bear all costs involved in, obtaining any government approvals required for the importation or sale of the Products.
7.
Taxes. All taxes, duties and other governmental charges (other than general real property and income taxes), including any interest or penalties thereon, imposed directly or indirectly on Omron or required to be collected directly or indirectly by Omron for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by Buyer to Omron.
8.
Financial. If the financial position of Buyer at any time becomes unsatisfactory to Omron, Omron reserves the right to stop shipments or require satisfactory security or payment in advance. If Buyer fails to make payment or otherwise comply with these Terms or any related agreement, Omron may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid accounts.
9.
Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses.
10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority.
11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron: a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship except in “break down” situations.
b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall constitute delivery to Buyer; c. All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Omron), at which point title and risk of loss shall pass from Omron to Buyer; provided that Omron shall retain a security interest in the Products until the full purchase price is paid; d. Delivery and shipping dates are estimates only; and e. Omron will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions.
12. Claims. Any claim by Buyer against Omron for shortage or damage to the
Products occurring before delivery to the carrier must be presented in writing to Omron within 30 days of receipt of shipment and include the original transportation bill signed by the carrier noting that the carrier received the Products from Omron in the condition claimed.
13. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the
Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION,
EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL-
ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS.
BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying
Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty.
See http:// www.omron247.com
or contact your Omron representative for published information.
14. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE
FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY
WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS
BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
15. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and their employees from and against all liabilities, losses, claims, costs and expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Omron is a party) which arises or is alleged to arise from Buyer's acts or omissions under these Terms or in any way with respect to the Products. Without limiting the foregoing, Buyer (at its own expense) shall indemnify and hold harmless Omron and defend or settle any action brought against such Companies to the extent based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party.
16. Property; Confidentiality. Any intellectual property in the Products is the exclusive property of Omron Companies and Buyer shall not attempt to duplicate it in any way without the written permission of Omron. Notwithstanding any charges to Buyer for engineering or tooling, all engineering and tooling shall remain the exclusive property of Omron. All information and materials supplied by Omron to Buyer relating to the Products are confidential and proprietary, and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party.
17. Export Controls. Buyer shall comply with all applicable laws, regulations and licenses regarding (i) export of products or information; (iii) sale of products to
“forbidden” or other proscribed persons; and (ii) disclosure to non-citizens of regulated technology or information.
18. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right and no course of dealing between Buyer and Omron shall operate as a waiver of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder without Omron's written consent. (c) Law. These Terms are governed by the law of the jurisdiction of the home office of the Omron company from which
Buyer is purchasing the Products (without regard to conflict of law principles). (d) Amendment. These Terms constitute the entire agreement between
Buyer and Omron relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. (e) Severability. If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. (f) Setoff. Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice. (g) Definitions. As used herein, “including” means “including without limitation”; and “Omron Companies” (or similar words) mean Omron Corporation and any direct or indirect subsidiary or affiliate thereof.
Certain Precautions on Specifications and Use
1.
Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the
Product in the Buyer’s application or use of the Product. At Buyer’s request,
Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system.
Buyer shall take application responsibility in all cases but the following is a non-exhaustive list of applications for which particular attention must be given:
(i) Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
(ii) Use in consumer products or any use in significant quantities.
(iii) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations.
(iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this Product.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS
RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
ADDRESS THE RISKS, AND THAT THE OMRON’S PRODUCT IS PROP-
ERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
2.
Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.
3.
Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
4.
Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product.
5.
Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions.
OMRON ELECTRONICS LLC • THE AMERICAS HEADQUARTERS
Schaumburg, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com
OMRON CANADA, INC. • HEAD OFFICE
Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron.ca
OMRON ARGENTINA • SALES OFFICE
Cono Sur • 54.11.4787.1129
OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE
S ã o Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br
OMRON CHILE • SALES OFFICE
Santiago 56.2206.4592
OMRON ELECTRONICS MEXICO SA DE CV • HEAD OFFICE
Apodaca, N.L. • 52.811.156.99.10 • [email protected]
W417-E1-03
OTHER OMRON LATIN AMERICA SALES
56.2206.4592
Note: Specifications are subject to change. © 2008 Omron Electronics LLC Printed in U.S.A.

Public link updated
The public link to your chat has been updated.
Advertisement