Kusam-meco KM 033 is a versatile digital clamp meter designed for a variety of electrical measurements. It features True RMS sensing for accurate readings of non-sinusoidal waveforms. It also offers a range of features including AmpTip low-current measurement mode, MAX/MIN and PEAK-HOLD recording modes, EF-detection for tracing live wiring, and a BeepLitTM function for continuity and diode testing. This meter is suitable for professional electricians, technicians, and hobbyists for troubleshooting and maintenance tasks.
PDF
Document
Advertisement
Advertisement
LIST OF PRODUCTS Digital Multimeter Digital AC & AC/DC Clampmeter AC Clamp Adaptor AC/DC Current Adaptor Thermo Anemometer Thermo Hygrometer Distance Meter Digital Lux Meter Network Cable Tester Power Factor Regulator Earth Resistance Tester Digital Panel Meters DC Power Supplies High Voltage Detector Calibrators Gas Analysers Frequency Counter Function Generator Phasing Sticks Battery Tester Waterproof Pen Testers Solar Power Meter EMF Detector Wood, Paper & Grain Moisture Meter Transistorised Electronic Analog & Digital Insulation Resistance Testers(upto 10 KV) Digital Sound Level Meter & Sound Level Calibrator Digital contact & Non-contact Type Tachometer Digital Non-contact (infrared) Thermometer Maximum Demand Controller/Digital Power Meter Digital Hand Held Temperature Indicators ® AN ISO 9001:2015 COMPANY AC TRUE RMS DIGITAL CLAMPMETER WITH EF-DETECTION, AMPTIP FUNCTION FOR LOW CURRENT MEASUREMENT ® G 17, Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA. Sales Direct : (022) 24156638 Tel. : (022) 24124540, 24181649. Fax : (022) 24149659 Email : [email protected] Website : www.kusamelectrical.com www.kusam-meco.co.in MODEL - KM 033 OPERATION MANUAL ® AC TRMS DIGITAL CLAMPMETER MODEL - KM 033 ® I. SAFETY : The meter meets UL / IEC / EN61010-1 Ed. 3.0, CAN / CSA C22.2 No. 61010-1Ed.3.0, UL/IEC/EN61010-2-032 Ed.3.0, UL/IEC/ EN61010-2-033 Ed. 1.0 to measurement CAT-III 600V and CAT-IV 300V, AC & DC. The accompanied test probe assembly meets UL/IEC/EN61010031 Ed. 2.0 to the same meter ratings or better. IEC 61010-031 requires exposed conductive test probe tips to be ≤ 4mm for CAT III & CAT IV ratings. Refer to the category markings on your probe assemblies as well as on the add-on accessories (like detachable Caps or Alligator Clips), if any, for applicable rating changes. TERMS IN THIS MANUAL : WARNING Identifies conditions and actions that could result in serious injury or even death to the user. CAUTION Identifies conditions and actions that could cause damage or malfunction in the instrument. WARNING : This manual contains information and warnings that must be followed for operating the meter safely and maintaining the meter in a safe operating condition. If the meter is used in a manner not specified by the manufacturer, the protection provided by the meter may be impaired. Observe proper safety precautions when working with voltages above 30 Vrms, 42.4 Vpeak or 60VDC. These voltage levels pose a potential shock hazard to the user. Do not expose this product to rain or moisture. The meter is intended only for indoor use. 01 ® ® Keep your hands/fingers behind the hand/finger barriers (of the MEASUREMENT CATEGORY III is applicable to test & measuring meter and the test leads where applicable) that indicate the limits of circuits connected to the distribution part of the building’s low-voltage safe access of the hand-held part during measurement. Inspect test leads, connectors and probes for damaged insulation or exposed metal periodically. If any defects are found, replace them immediately. Only use the test lead provided with the equipment or a UL Listed Probe Assembly rated CAT III 600V or better. MAINS installation. Examples are measurements on distribution boards (including secondary meters), circuit-breakers, Cables, bus-bars, junction boxes, switches, socket-outlets, stationary motors in the fixed installation, and equipment for industrial use. MEASUREMENT CATEGORY II is applicable to test & measuring INTERNATIONAL ELECTRICAL SYMBOLS : Caution ! Refer to the explanation in this Manual. circuits connected directly to utilization point (socket outlets & similar points) of the low-voltage MAINS installation. Examples are measurements on MAINS CIRCUITS of household appliances, portable tools Caution ! Risk of electric shock. Earth (Ground) Double Insulation or Reinforced insulation 3~ The instruments conform to CENELEC Low-voltage directive 2014/ Fuse 35/EU, Electromagnetic compatibility directive 2014/30/EU and AC--Alternating Current RoHS directive 2015/863/EU. DC--Direct Current III SPECIAL FEATURES : Application around and removal from hazardous live conductors is permitted. AmpTip low-current range calibrated at Jaw-tip for slim-conditions for accurate readings MAX / MIN Recording mode. MAX / MIN Crest (Peak-Hold) mode. Relative-zero mode. Display Hold EF-Detection (NCV). Back-lighted easy-to-read LCD display Fully Autoranging BeepLitTM Feature. Three-phase Alternating Current BRIEF INFORMATION ON MEASUREMENT CATEGORIES MEASUREMENT CATEGORY IV is applicable to test & measuring circuits connected at the source of the building’s low-voltage MAINS installation. and similar equipment. II. CENELEC Directives : Examples are measurements on devices installed before the main fuse or circuit breaker in the building installation. 02 TM 03 ® ® GENERAL SPECIFICATIONS : SAFETY : Sensing : True RMS Safety : Certified per IEC/UL/CSA_C22.2_# / EN standards. 61010-1 Ed.3.0, 61010-2-032 Ed. 3.0,61010-2 033 Ed. 1.0 & 61010-031 Ed. 2.0 to Jaws Opening size : 26mm Max. Measurement Categories CAT III 600V AND CAT IV 300V AC & DC. Display : 3-5/6 digits 6000 counts Overload Protection : Update Rate : 5 per second nominal Current via jaws : 600A DC / AC rms at <400Hz. Polarity : Automatic Voltage via terminal: 660V DC / 920VAC rms. Operating Temperature : 0ºC to 40ºC Other functions via terminals : 600V DC / VAC rms Relative Humidity : Maximum relative humidity 80% for temperature up to 31ºC decreasing inearly to 50% relative humidity at 40ºC. E.M.C. : Meets EN61326-1:2013 Altitude : Operating below 2000m DCA and ACA Functions, in an RF field of 1V/m : Storage Temperature : -20°C ~ 60°C, <80% R.H. (with battery removed) o Temperature Coefficient : Nominal 0.1 x (specified accuracy) / C @ o o o Pollution Degree : 2 o (0 C –– 18 C or 28 C –– 40 C), or otherwise specified Power Supply : Standard 1.5V AAA Size Battery X 2 Power Consumption : typical 14mA for current function. Low Battery : Below approx. 2.85V for Capacitance & Hz Total Accuracy = Specified Accuracy + 40 digits at around 87MHz DCA & Ohm Functions, in an RF field of 1V/m : Total Accuracy = Specified Accuracy + 25 digits Other Functions, in an RF field of 3V/m : Total Accuracy = Specified Accuracy + 20 digits Transient Protection : 6.0kV (1.2/50s surge) Rugged Fire retarded housing. Below approx. 2.5V for other functions APO timing : Idle for 32 minutes LVD EN61010-1/61010-2-032/61010-2-033 to CAT III 600V & CAT IV 300V Accessories : Test leads set, Users Manual, Carrying case. APO Consumption : typical 5A Dimension : 188(L) x 66(W) x 32(H)mm Weight : approx 202 gms. 04 05 ® ® DC VOLTAGE ELECTRICAL SPECIFICATIONS : Range Accuracy is ± (% of reading digits + number of digits) or otherwise o o specified, at 23 C ± 5 C. Maximum Crest Factor <2 :1 at full scale & <4:1 at half scale or otherwise specified, and with frequency spectrum 600.0 V Accuracy Resolution 0.1 V ±(1.0%rdg + 5dgts) Input Impedance : 10M, 100pF nominal not exceeding the specified frequency bandwidth for non-sinusoidal AC VOLTAGE (with Digital Low-Pass Filter) waveforms. Range REGULAR AC CLAMP-ON CURRENT Range Accuracy Resolution 1) 2) 600.0 V 50Hz ~ 100Hz 600.0 A 0.1 A ±(1.5%rdg + 5dgts) 0.1 A ±(2.0%rdg + 5dgts) 100Hz ~ 400Hz 0.1 V ±(1.5%rdg + 5dgts) Input Impedance : 10M, 100pF nominal RESISTANCE 600.0 A 1) Induced error from adjacent current-carrying conductor : < 0.6A/A 2) Specified accuracy is for measurements made at the jaw center. When the conductor is not positioned at the jaw center, add 2% to specified accuracy for position errors. CLAMP-ON AmpTipTM AC CURRENT Range Accuracy Resolution 50Hz ~ 60Hz Range Resolution 600.0 0.1 60.00K 10 600.0K 100 6000K 1 k Accuracy ±(1.0%rdg + 5dgts) 1) Resolution Accuracy 0.01 A ±(1.0%rdg + 5dgts) Open Circuit Voltage : 1.0VDC typical 50Hz ~ 60Hz BeepLitTM DIODE TESTER 60.00 A 1) Induced error from adjacent current-carrying conductor : < 0.06A/A DCA Range Resolution 200.0 A 0.1 A 2000 A 1 A Accuracy ±(1.0%rdg + 5dgts) Burden Voltage : 3.5mV/A 06 Range 3.000 V Accuracy 1) Resolution 1 mV ±(1.5%rdg + 5dgts) Test Current : 0.3mA typically Open Circuit Voltage : < 3.5VDC typically Short Beep Alert Threshold : Drop across 0.850V BeepLitTM ON Threshold : <0.100V Audible indication : Beep Sound Visible Indication : LCD Backlight. 07 ® ® CAPACITANCE Range Resolution 200.0 F 0.1 F Accuracy 1) ±(2.0%rdg + 4dgts) 2500 F 1) 1 F Accuracies with film capacitor or better BeepLitTM CONTINUITY TESTER Continuity Threshold Between 30 & 480 Continuity ON Response Time 15ms approx. Audible Indication Beep sound Visible Indication LCD Backlight HZ LINE LEVEL FREQUENCY Function Sensitivity1) (Sine RMS) Range 50 V 5.00Hz~999.9Hz 600 V Accuracy : ±(1%rdg + 5dgts) DC-bias, if any, not more than 50% of Sine RMS 1) TEMPERATURE Range Accuracy 1)2) -40.0ºC ~ 99.9ºC ± (1.0% + 1.0ºC) 100.0ºC ~ 400ºC ± (1.0% + 1ºC) -40.0ºF ~ 211.8ºF ± (1.0% + 2.0ºF) 212ºF ~ 752ºF ± (1.0% + 2ºF) 1) Accuracies assume meter interior has the same temperature of the ambient (isothermal stage) for a correct junction voltage compensation. Allow the meter & the type-K probe set to reach isothermal stage for a significant change of ambient temperature. It can take up to an hour for changes >5°C. 2) Type-K thermocouple range & accuracy not included. NON-CONTACT EF-DETECTION Bar-Graph Indication EF-H (Hi Sensitivity) EF-L (Lo Sensitivity) Typical Voltage (Tolerance) - 10V (2V~20V) 40V (10V~70V) -- 20V (4V~40V) 80V (20V~140V) --- 40V (8V~70V) 160V (40V~280V) ---- 80V (16V~140V) 320V (80V~560V) ----- 160V (>40V) 500V (>160V) Indication : Bar-graph segments & audible beep tones proportional to the field strength. Detection Frequency : 50/60Hz Detection Antenna : Inside the top side of the stationary jaw Probe-Contact EF-Detection : For more precise indication of live wires, such as distinguishing between live and ground connections, use one single probe to test via terminal COM for direct Metal Probe-contact EF-Detection to achieve the most distinctive indication. CREST (Peak-Hold) Applicability Accuracy Voltage & Non-invasion Current functions Add ± 250 digits to specified accuracy for changes > 5ms in duration. 08 09 ® ® VII. OPERATION : VI. PRODUCT DESCRIPTION : This manual uses only representative model(s) for illustrations. Please refer specification details for function availability to this model. 1. Antenna area for Non-Contact EFDetection 1 11 10 2 + + 2. Jaw center indicator at where best current accuracy is specified. 3. Push-buttons for special functions & features. 9 4. Rotary Selector to turn the power ON/OFF and Select a function. MAX 600A 600V CAT III 300V CAT IV CREST REC 5. 3-5/6 digits 6000 counts numeric LCD display. 3 V 4 OFF SELECT DCV Inputs are made through the test lead terminals COM/+. MAX 600A 600V CAT III 300V CAT IV 6.0.3.3 10. Clamp Jaw for Clamp-on current magnetic field pick up. V + 11. Additional center indicator for AmpTipTM Low-current function, at where best AmpTipTM current accuracy is specified. 6 300V CAT IV 600V CAT III 7 10 V A EF V Hz V SELECT ~ 120.8 + COM 300V CAT IV 600V CAT III SELECT 1 A EF Hz V V OFF SELECT V COM A A EF OFF V CREST REC A Hz V Hz MAX 600A 600V CAT III 300V CAT IV CREST REC A 9. Hand/Finger Barrier to indicate the limits of safe access of the meter. MAX 600A 600V CAT III 300V CAT IV CREST REC 8. Jaw trigger for opening the clamp jaw. 5 3 Note : ACV and Line-level Hz function are equipped with low-pass filter, & are capable of dealing with VFD (Variable Frequency Drive) signals. It also improves ACV reading stability in noisy electrical environments. 7. Common (Ground reference) Input Jack for all functions EXCEPT the Clamp-on current and Non-Contact EF-Detection functions. A EF Hz V ACV, Line-level Hz : Inputs, are made through the test lead terminals COM/+. Defaults at ACV Function. Press SELECT button momentarily to select Line-level Hz function. 6. Input Jack for all functions EXCEPT non-invasive current functions. A 8 WARNING : Before and after hazardous voltage measurements, test the voltage function on a known source such as line voltage to determine proper meter functioning. OFF SELECT 60.01 Hz + COM 300V CAT IV 600V CAT III 11 ~ 009.7 V + COM 300V CAT IV 600V CAT III ® ® Clamp-on AmpTipTM ACA Clamp-on Current Measurements : Application & Removal of the Jaws Press the jaw trigger & clamp the jaws around conductor(s) of only + + Input is made via the clamp jaws where best accuracy is specified near the jaw one single pole of a circuit for load current measurements. Make TIP-CENTER area for low-current sure the jaws are completely closed, or else it will introduce measure- MAX 600A 600V CAT III 300V CAT IV CREST ment errors. Enclosing conductors of more than one pole of a circuit measurements of thin conductors. REC A may result in differential current (like identifying leakage current) V Defaults at ACA function. A EF Hz V measurements. Align the conductors to the Jaws center indicators OFF Press SELECT button momentarily to select DCA function. SELECT (Regular or AmpTipTM indicators where applicable) as much as ~ 28.0 1 possible to get the best measuring accuracy. For removal, press the A jaw trigger and remove the jaws from the conductors. + COM 300V CAT IV 600V CAT III Adjacent current-carrying devices such as transformers, motors and conductor wires may affect measurement accuracy. Keep the jaws Clamp-on Regular ACA away from them as much as possible to minimize influence. + + WARNING : Input is made via the clamp jaws where This Clamp-on meter series is designed to directly apply around or remove from uninsulated hazardous live conductors. MAX 600A 600V CAT III 300V CAT IV REC But still, individual protective equipment must be used if hazardous live parts CREST A V A EF in the installation where measurement is to be carried out could be rated frequency (400Hz). Circulating currents may cause the magnetic circuits of the Jaws reach a hazardous temperature. CENTER area. Defaults at ACA function. Hz V OFF accessible. Do not use the meter to measure currents above the best accuracy is specified at the jaw Press SELECT button momentarily to SELECT ~ 32 18 select DCA function. A + COM 300V CAT IV 600V CAT III 12 13 ® Resistance, BeepLitTM Continuity & ® BeepLitTM Diode : Inputs are made through the test lead terminals COM/+. Defaults at Resistance. Press SELECT button momentarily to select the subject functions in sequence. CAUTION : Using Resistance, BeepLitTM Continuity or BeepLitTM Diode function in a live circuit will produce false results and may damage the meter. In many cases, the suspected components must be disconnected from the circuit to obtain an accurate measurement reading. BeepLitTM Continuity : This function is having improved convenience for checking wiring + + + + + + + + connections and operation of switches. Resistance threshold is being used. A continuous beep tone together with flashing display backlight MAX 600A 600V CAT III 300V CAT IV CREST Hz V OFF k Reading indication : Forward voltage drop (forward baised) for a good + COM 300V CAT IV 600V CAT III A EF V Hz V Hz V OFF OFF A EF SELECT 320.8 Diode : V OFF SELECT A A EF Hz V SELECT TM V CREST REC A A EF MAX 600A 600V CAT III 300V CAT IV REC A CREST REC A V BeepLit MAX 600A 600V CAT III 300V CAT IV CREST REC indicate a complete wire. Such audible and visible indications improve continuity readabilities in noisy working environments. MAX 600A 600V CAT III 300V CAT IV SELECT 1 SELECT SELECT 1 00 12 V + COM + COM 300V CAT IV 600V CAT III 300V CAT IV 600V CAT III 0.602 V V + COM 300V CAT IV 600V CAT III silicon diode is between 0.400V to 0.900V. A higher reading indicates a leaky diode (defective). A zero reading indicates a shorted diode (defective). An over-range display indicates an open diode (defective) Reverse the test leads connections (reverse biased) across the diode. The digital display shows over-range if the diode is good. Any other readings indicate the diode is resistive or shorted (defective). Beep-Alert & BeepLit TM EF-Detection of Electric Field Defaults at high sensitivity EF-H. The meter displays “EF-H” when it is ready. If it is too sensitive for your applications, press SELECT button momentarily to select lower sensitivity “EF-L”. The detected Electric Indication : When the display reading drops across 0.850V, the meter alerts a Field strength is indicated as a series of bar-graph segments on the display plus variable beep tones. short beep to signal a reasonable forward voltage drop of common diodes. However, if the reading further drops below 0.100V, the meter gives a continuous beep tone together with flashing display backlight to indicate a shorted diode or a complete wire. it is similar to that of BeepLitTM Continuity function but BeepLitTM Diode, instead, is based on voltage threshold to indicate a complete wire. 14 Non-Contact EF-Detection (NCV) : An antenna is located along the top-right end of the stationary clamp jaw, which detects electric field that surrounds energized conductors. It is ideal for tracing live wiring connections, locating wiring breakage and to distinguish between live or earth connections. 15 ® ® Probe-Contact EF-Detection : For more precise indication of live wires, such as distinguishing between Live and Ground connections, use one single probe to test via terminal COM for direct metal Probe-Contact EF-Detection to achieve the most distinctive indication. + + + + + + + DCA Current function : Inputs are made through the test lead terminals COM/+. Defaults at EF-Detection function. Press SELECT button momentarily two times to select DCA function. Application Notes : + MAX 600A 600V CAT III 300V CAT IV MAX 600A 600V CAT III 300V CAT IV MAX 600A 600V CAT III 300V CAT IV CREST MAX 600A 600V CAT III 300V CAT IV CREST REC CREST REC MAX 600A 600V CAT III 300V CAT IV CREST REC CREST REC REC A A A V A A EF V Hz V A EF OFF V Hz V OFF OFF SELECT SELECT SELECT 1 1 EF-H + COM 300V CAT IV 600V CAT III A SELECT OFF EF SELECT SELECT 128.1 + COM + COM + COM 300V CAT IV 600V CAT III + MAX 600A 600V CAT III 300V CAT IV 300V CAT IV 600V CAT III + + MAX 600A 600V CAT III 300V CAT IV CREST CREST REC REC A A V A EF V Hz V Hz V OFF OFF SELECT + COM 300V CAT IV 600V CAT III + A EF Hz V A EF Hz V OFF EF SELECT A EF V Hz V V A A EF 300V CAT IV 600V CAT III The DCA function designed especially for HVAC/R flame sensor applications. The 0.1A resolution is useful for identifying the minute current changes in flame detector applications. Flame signal current check should indicate steady flame signal of at least 2A for a rectification type, or 1.5A for an ultraviolet type (8A for self checking systems). If a flame signal current with inadequate strength or fluctuation beyond 10%, check the following to avoid the risk of unwanted flame relay dropout : For gas or oil flames (Minipeeper) : Low supply voltage Detector location Defective detector wiring Faulty Minipeeper Dirty viewing windows For oil flames (Photocell) : Detector location & wiring Smoky flame or poorly adjusted air shutter Faulty Photocell Temperature over 165ºF (74ºC) at photocell SELECT + COM + COM 300V CAT IV 600V CAT III 300V CAT IV 600V CAT III Live Ground 16 For gas flames (Flame Rod) : Ignition interference (A flame signal current difference with the ignition both on and off greater than 0.5A indicates the presence of ignition interference). Insufficient ground (must be at least 4 times the detector area). Flame lifting off burner head (ground), or not continuously in contact with the flame rod. Temperature in excess of 600ºF (316ºC) at the flame electrode insulator causing short to ground. 17 ® ® Capacitance & Temperature : Inputs are made through the test lead terminals COM/+. Defaults at Capacitance. Press SELECT button momentarily to select °C (Celsius) and °F (Fahrenheit) in sequence (°F selection can be left out as factory calibration default for countries that only accept metric units). CAUTION : Discharge capacitors before making capacitance measurements. Large value capacitors should be discharged through an appropriate resistance load. Using capacitance function in a live circuit will produce false results and may damage the meter. In many cases the suspected components must be disconnected from the circuit to obtain accurate measurement readings. HOLD : Hold feature freezes the display for later view. LCD “ H ” turns on. Press the HOLD button momentarily to toggle the hold feature. MAX 600A 600V CAT III 300V CAT IV MAX 600A 600V CAT III 300V CAT IV CREST MAX 600A 600V CAT III 300V CAT IV CREST REC A V A A EF V Hz V A EF V Hz V OFF OFF SELECT SELECT 18.35 1 F + COM SELECT 1 25.8C + COM 300V CAT IV 600V CAT III 78.4F + + + COM 300V CAT IV 600V CAT III – – A EF Hz V OFF SELECT SELECT F RECORD MODE : Press REC button momentarily to activate MAX/MIN recording mode. LCD MAX & MIN turn on. The meter beeps when new MAX (maximum) or MIN (minimum) reading is updated. Press the button momentarily to read the MAX, MIN and MAXMIN (active measurement) readings in sequence. Press the button for 1 second or more to exit this mode. Auto-Power-Off is disabled automatically in this mode. REC A CREST REC 300V CAT IV 600V CAT III – + + + + + – – – – Note : Be sure to insert the banana plug type-K temperature bead probe Bkp60 with correct +- polarities. Banana pins to type-K socket adapter Bkb32 (Optional purchase) can be used to accept other type-K probes using standard miniature plug. Temperature accuracies assume meter interior has the same temperature of the ambient (isothermal stage) for a correct junction voltage compensation. Allow the meter and the type-K probe set to reach isothermal stage for a significant change of ambient temperature. It can take up to an hour for changes > 5°C. 18 5ms CREST MODE : Press CREST button for one second or more to activate CREST mode (instantaneous PEAK-HOLD) to capture current or voltage peak values in duration as short as 5ms. LCD C & MAX turn on. The meter beeps when new C MAX (maximum) or CMIN (minimum) reading is updated. Press the button momentarily to toggle the C MAX and C MIN readings. Press the button for 1 second or more to exit this mode. Auto-powerOff is disabled automatically in this mode. LCD Backlight & Auto-Backlight-Off (ABO) : Press the SELECT button for 1 second or more to toggle the LCD backlight. The ABO mode turn the LCD backlight off automatically after idling for 10 minutes to extend battery life. See Power-on Options section for disabling ABO. 19 ® ® Intelligent Auto-Power-Off (APO) : V. MAINTENANCE : The Auto-Power-Off (APO) mode turns the meter off automatically to extend battery life after approximately 32 minutes of no specified activities, where applicable, below : WARNING : To avoid electrical shock, disconnect the meter from any circuit, remove the test leads from the input jacks and turn OFF the meter before opening the case. Do not operate with open case. 1. Rotary switch or push button operations. 2. Significant measuring readings of above 8.5% of ranges. 3. Non-over-range readings for Resistance, Continuity or Diode function. 4. Non-zero readings for Hz function. In other words, the meter will intelligently reset the APO mode when it is under normal measurements. To wake up the meter from APO, press the SELECT button momentarily and release, or turn the rotary switch OFF and then back on. Always turn the rotary switch to the OFF position when the meter is not in use. POWER-ON OPTION : Disabling APO & ABO Press & hold the SELECT button while powering on the meter can disable both APO & ABO features temporarily during the power on session. The LCD will display “dAPO” to confirm selection before the SELECT button is released. Trouble Shooting : If the instrument fails to operate, check batteries and test leads etc., and replace as necessary. Double check operating procedure as described in this manual. Cleaning and Storage : Periodically wipe the meter & the test probe assembly with a damp cloth and mild detergent. Do not use abrasives or solvents. Allow to dry completely before operating. If the meter is not to be used for periods of longer than 60 days, remove the batteries and store them separately. Battery replacement : The meter uses standard 1.5V AAA Size (IEC R03) battery X 2. Loosen the 2 captive screws from the battery cover case. Lift the battery cover case. Replace the batteries. Replace battery cover case. Re-fasten the screws. Shortening APO idling time for inspection Press & hold the HOLD button while powering on the meter can shorten the APO idling time to 5 seconds temporarily during the power on session. It is designed mainly for production inspection. Showing all LCD segments for inspection Press & hold the REC button while powering on the meter can hold & show all LCD segments before the button is released. It is designed mainly for production inspection. 20 21 ® ® WARRANTY MUMBAI TEST CERTIFICATE AC TRMS DIGITAL CLAMPMETER This Test Certificate warrantees that the product has been inspected and tested in accordance with the published specifications. The instrument has been calibrated by using equipment which has already been calibrated to standards traceable to national standards. KM 033 MODEL NO. ________________ SERIAL NO. ___________ DATE: ___________ QC ISO 9001 REGISTERED KUSAM-MECO PASS 22 Each “KUSAM-MECO” product is warranted to be free from defects in material and workmanship under normal use & service. The warranty period is one year (12 months) and begins from the date of despatch of goods. In case any defect occurs in functioning of the instrument, under proper use, within the warranty period, the same will be rectified by us free of charges, provided the to and fro freight charges are borne by you. This warranty extends only to the original buyer or end-user customer of a “KUSAM-MECO” authorized dealer. This warranty does not apply for damaged Ic’s, fuses, burnt PCB's, disposable batteries, carrying case, test leads, or to any product which in “KUSAM-MECO’s” opinion, has been misused, altered, neglected, contaminated or damaged by accident or abnormal conditions of operation or handling. “KUSAM-MECO” authorized dealer shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of “KUSAM-MECO”. “KUSAM-MECO’s” warranty obligation is limited, at option, free of charge repair, or replacement of a defective product which is returned to a “KUSAM-MECO” authorized service center within the warranty period. THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. “KUSAM-MECO” SHALL NOT BE LIABLE F O R A N Y S P E C I A L , I N D I R E C T, I N C I D E N TA L O R CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE WHATSOEVER. All transaction are subject to Mumbai Jurisdiction. 23 ">

Download
Just a friendly reminder. You can view the document right here. But most importantly, our AI has already read it. It can explain complex things in simple terms, answer your questions in any language, and help you quickly navigate even the longest or most compilcated documents.
Advertisement
Key features
- True RMS sensing
- AmpTip low-current measurement
- MAX/MIN & PEAK-HOLD
- EF-detection
- BeepLitTM function
Frequently asked questions
This mode allows for accurate measurement of current in thin conductors by calibrating the clamp meter at the jaw tip.
EF-detection uses the clamp meter to detect electric fields surrounding energized conductors, allowing for tracing live wiring, locating breaks, and distinguishing between live and ground connections.
BeepLitTM functions provide audible and visual indications for continuity testing and diode testing. A continuous beep and flashing backlight indicate a complete wire in continuity mode and a short across a diode in diode test mode.