Advertisement
Advertisement
SMART REVERSE OSMOSIS UNIT Installation & Operating Manual INDEX 1. SPECIFICATIONS 2. WARNINGS & SYMBOLS 1 2 3. INSTALLATION 3 4. OPERATION 6 5. MAINTENANCE 6 6. TROUBLE SHOOTING 8 7. TERMS OF WARRANTY 9 © Davis & Shirtliff Ltd 2020 Contents herein are not warranted Congratulations on selecting a Dayliff Smart Reverse Osmosis. They are manufactured to the highest standards and if installed and operated correctly will give many years of efcient and trouble free service. Careful reading of this Installation Manual is therefore important, though should there be any queries they should be referred to the equipment supplier. 1. SPECIFICATIONS A five stage water treatment purifier suitable for treating water from clean municipal sources or borehole water for undersink installation that includes: • Output 1,800L/day, • Three stage sediment & carbon cartridge pre-treatment with easy to replace cartridges and LED replacement reminder. • Reverse osmosis purification using Hidrotek membranes with up to 50% recovery. • Post Carbon stage for water conditioning. • Supplied complete with 24VDC diaphragm pump • Compact tankless design for installation within minimal space. • Two outlet options – RO water and pre-treated water. • Operating Parameters: Chlorine level <0.2ppm, TDS<250ppm, Water Temperature 5-450C. TECHNICAL SPECIFICATIONS Feed Water Quality: Municipal tap water Voltage and Frequency: 100~240V, 50/60Hz PowerInput:96W Purified Water Flow: 1.2L/Min 1 Feed Water Temperature: 5~45℃ Feed-water TDS: ≤ 250ppm Feed-water Chlorine level: ≤ 0.2ppm Rejection: 90~99% Feed-Water Pressure: 0.1~0.4 Mpa Water Treatment Process Flow Diagram Technological Process Feed Water T33 Filter PP Filter RO Water GAC Filter CTO Filter RO Filter Puried Water (Optional) Special Pump Drain Water Sewer Pipe Goose Faucet Diagram DC24V+ Inlet Water Solenoid Water Indicator Light Flush Water Solenoid Water Main Control Panel Pump Leakage Detector Low Pressure Switch High Pressure Switch DC24V- 2 2. WARNINGS & SYMBOLS Wash and replace cartridges regularly. WARNING WARNING Do not disassemble parts randomly, it may cause leakage or damage. Do not use power supply with disproportional rated voltage. WARNING Please pull the power plug and cut off the feed water valve if long term storage. CAUTION Do not store or explore in an environment of 0℃ or below. WARNING Handle with care when discharging, moving and installing. WARNING WARNING Please turn off the feed water ball valve and cut off the source water to avoid the “water hammer phenomenon” which may lead to leakage or damage to housings and lters if go out in daytime or after the last use at night. Please cut off power and source water at once in case troubles occur and ask professional staff to repair. WARNING Professional staff are advised to replace cartridges. WARNING WARNING It is normal to hear vibration sound when system is producing water. 3 NOTE Water hammer is a pressure surge or wave caused when water in motion is forced to step or change direction suddenly.When resident in building close his valve suddenly, a pressure wave propagates in the pipeline of building. 3. INSTALLATION Product and Accessories Main Body Six Filter Cartridges Includes spun PP filter(PP), Granular c a r b o n f i l t e r ( G AC ) , b l o c k c a r b o n f i l t e r ( C TO ) , 2 p c s x reverse osmosis membrane(RO), and post activated carbon filter(T-33). One Accessory Box Includes faucet, 3-way ball valve, three pipes, instruction book, adapter and drain clamp. Goose Faucet Instruction Book 3-way Ball Valve Adapter 4 3 pipes (red, blue & white) Drain Clamp Functional Schematic Diagram RO water faucet Tap water faucet Tap water pipe Power Puried water (optional) Drain water pipe (1/4" red pipe) RO water pipe (1/4" blue pipe) Inlet water pipe (3/8" white pipe) Leave at least 100mm space at the back of products for bending pipes Installation Ball Valve and Tee Fittings Ÿ Install Tee Fitting and 3-way ball Valve as per diagram. Ÿ Wrap threads of 3-way ball Valve and Tee Fitting with Teflon tape. Ÿ Connect inlet water pipe (3/8” white) from unit to Feed Water Valve. Ÿ Install 3-way ball valve to Tee fitting, and then connect to source water. 5 3-way ball valve Installation for Goose Faucet Ÿ Select a convenient location near your sink to place the faucet. Ÿ Drill a hole 12mm in diameter in counter top. Ÿ Place washers, plates, seals and nuts in order as per diagram and tighten on to counter. Ÿ Attach RO Water pipe (1/4” blue) to the bottom of faucet and connect tubing to unit Installation for Drain Clamp Ÿ Place drain clamp on drain pipe above the drain trap and tighten securely. Ÿ Using the drain clamp as a guide, drill a 6mm hole, enough for the 1/4” tubing to pass through one side of the drain pipe. DO NOT drill through both sides. Ÿ Connect Drain tubing (1/4” red) from unit to Drain Clamp Drain Pipe M6x35 Screw M6 Nut Drain Clamp Front Plate Drain Clamp Back Plate Insert Compression Nut Drain Tubing 6 First Use Instruction 1. Connect RO system with adapter, then the power indicator light is on, buzzer rings three times, machine flushes for 90 seconds and indicator light is flashing in blue slowly. 2. RO system begins making water and indicator light is flashing in blue slowly, system is in standby mode and indicator light keeps in blue when water tank is full. 3. Machine stops making water and indicator light keeps in red, buzzer rings 30 times after being working continuously for 6 hours or water leakage is detected. Cartridges Replacement and Reminder Recommended Replacement Period for Cartridges Cartridges Replacement Please cut off the water, turn off the power, open RO water faucet and discharge water in pipeline before replacing cartridges. 7 1. Push side board according to arrow direction 2. Lift up cartridge 30°, rotate anticlockwise then remove it. 3. Install new cartridge by rotating clockwise according to specifications, then fix the side board. 8 Please reset cartridges after replacement NOTE 6. TROUBLE SHOOTING PROBLEM Water pump is out of service and system does not work Water pump works but system does not work Constantly running water in downtime Cannot stop working when pressure tank is full or repetitive starting POSSIBLE CAUSE SOLUTION Insufficient feed water pressure No power or power failure Increase feed water pressure Power-on High pressure switch is out of order Replace high pressure switch Pump is blocked and adapter fuse burn-out Replace adapter and repair water pump RO membrane is blocked Water pump pressure loss Replace RO membrane Flush solenoid valve is damaged Replace flush solenoid valve Inlet water solenoid valve damaged Replace inlet water solenoid valve High pressure switch is damaged Repair or replace high pressure switch Check valve is damaged Replace Check valve 9 4 Repair water pump 7. TERMS OF WARRANTY i) General Liability Ÿ In lieu of any warranty, condition or liability implied by law, the liability of Dayliff in respect of any defect or failure of equipment supplied is limited to making good by replacement or repair (at the Company’s discretion) defects which under proper use appear therein and arise solely from faulty design, materials or workmanship within a specified period. This period commences immediately after the equipment has been delivered to the customer and at its termination all liability ceases. Also the warranty period will be assessed on the basis of the date that the Company is informed of the failure. Ÿ The warranty applies solely to equipment supplied and no claim for consequential damages, however arising, will be entertained. Also the warranty specifically excluded defects caused by fair wear and tear, the effects of careless handling, lack of maintenance, faulty installation, incompetence on part of the equipment user, Acts of God or any other cause beyond the Company’s reasonable control. Also, any repair or attempt at repair carried out by any other party invalidates all warranties. ii) Standard Warranty If equipment failure occurs in the normal course of service having been competently installed and when operating within its specified duty limits warranty will be provided as follows:Ÿ Up to 1 year - The item will be replaced or repaired at no charge. Ÿ Over 1 year, less than two years - The item will be replaced or repaired at a cost to the customer of 50% of the Davis & Shirtliff market price. The warranty on equipment supplied or installed by others is conditional upon the defective unit being promptly returned free to a Davis & Shirtliff ofce and collected thereafter when repaired. No element of site repair is included in the warranty and any site attendance costs will be payable in full at standard charegeout rates. Also proof of purchase including the purchase invoice must be provided for a warranty claim to be considered. 6 10 www.davisandshirtliff.com INS463A-09/20 ">

Download
Just a friendly reminder. You can view the document right here. But most importantly, our AI has already read it. It can explain complex things in simple terms, answer your questions in any language, and help you quickly navigate even the longest or most compilcated documents.
Advertisement