The ECCS I-PLUG pdf is a single-use USB temperature data logger that records temperature measurements over a set period of time. It is designed to monitor the temperature of sensitive goods during transportation and storage. The device features a range of configurable settings such as: recording interval, alarm thresholds, and user-defined text. The device can be used in a variety of applications, such as the transportation of pharmaceuticals, food, and other temperature-sensitive products.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

ECCS I-PLUG pdf User Manual | Manualzz
ECCS I-PLUG pdf Single use USB Temperature Data Logger
ECCS I-PLUG pdf USER MANUAL
Company: ECCS – Escort Cold Chain Solutions SA
Brand Name: I-PLUG pdf logger
Product Description: Single use USB Temperature Data Logger
FEATURES AND ADVANTAGES:
• Dimensions: 7.5 cm x 4 cm x 0.5 cm
• Temperature measurement range: -40 to +65 Degrees Celsius
• Temperature resolution: 0.01 °C
• Data storage capacity: 8000 Measurements
• Log cycle: 5 days to 90 days
• Data Sampling Interval: 1 second to 27 minutes
• No software needed
• Track and trace of settings, graph and readings in web portal.
STANDARD AVAILABLE DURATIONS:
1
2
3
4
5
6
7
Total Time
(Days)
5
10
30
40
60
75
90
Log Cycle
(Minutes)
1
2
6
8
11
14
17
APPEARENCE OF I-PLUG pdf :
I-PLUG pdf
1.0 Dec.14
Page 1 / 4
ECCS I-PLUG pdf Single use USB Temperature Data Logger
How does it work :
How to START it ?
When you are ready to use I-PLUG pdf Logger, press the START button till the 4 LED’s
flash – release only when the GREEN LED is active.
The GREEN LED will remain active during the first 2 hours of recording.
After the first 2 hours of recording, press briefly any of the two buttons to get the device
status (see meanings bellow)
How to STOP it ?
I-PLUG pdf is programmed with a typical trip duration, and will keep recording until the end
of this trip duration
There are two different ways to STOP the device before the end of the trip duration :
-
Press the STOP button during 6 seconds till the 4 LED’s flash – release only when the
RED LED is active and fixed.
Connect the device on the USB port of the computer
Once stopped, The RED LED will remain active till the end of the battery life.
CONFIGURING THE I-PLUG pdf
The I-PLUG pdf data logger comes already configured to standard formats according to your
purchase.
The standard trip duration is 90 DAYS.
Nevertheless if you wish to change the configuration like changing the recording time, adding
alarms or entering text in the device memory, you just need to plug it in a computer before
being activated and use the I-PLUG pdf manager software.
Get the I-PLUG pdf manager software in the “Downloads” section of our website
www.escortcoldchain.com
I-PLUG pdf
1.0 Dec.14
Page 2 / 4
ECCS I-PLUG pdf Single use USB Temperature Data Logger
USING THE LEDS INDICATORS
The LEDS will give you valuable information of the conditions of your shipment as indicated
in below table.
If you press START or STOP button briefly, while I-PLUG+ works, LEDS will blink. Here
the meanings:
APPEARENCE OF I-PLUG pdf
MEANING when any button
pressed
Blinking Green : This confirms
that the device is already started.
NOTE : there is a fixed green
LED during the first 2 hours of
recording.
Fixed Red : Device is in a
STOP position
Blinking Blue : low alarm has
been reached
Fixed Blue : ultra low alarm has
been reached
Blinking Orange : high alarm
has been reached
Fixed Orange : ultra high alarm
has been reached
NOTE : orange LED
automatically blinks every time
the device makes a temperature
record.
I-PLUG pdf
1.0 Dec.14
Page 3 / 4
ECCS I-PLUG pdf Single use USB Temperature Data Logger
4 blinking LED : device is not
started
CONNECTING TO THE COMPUTER:
As soon as the I-PLUG pdf is connected to the PC via the USB port the computer will
automatically detect the device.
The I-PLUG pdf will be detected by the computer as a USB disk drive and will be recognized
without any driver installation process.
USING THE I-PLUG CONNECTOR FOR ADDED BENEFITS :
Download the free I-PLUG Connetor software on
www.escortcoldchain.com or
www.ipluglogger.com click the button “DOWNLOAD I-PLUG pdf Connector”. You do not
need to register to download the software.
TRACK AND TRACE OF THE I-PLUG pdf:
Once you have downloaded the recordings from the I-PLUG pdf logger the I-PLUG
Connector will automatically send the data to the web, and allow you to extract data in excel
files, zoom on the graph and many other features.
Devices connected with the I-PLUG pdf Connector will automatically send to the web the
temperature recordings they have in memory.
To access the WEB TRACKING PORTAL go to the website www.escortcoldchain.com or
www.ipluglogger.com and click on the icon TRACK and TRACE I-PLUG pdf LOGGER,
then write on the field SEARCH the serial number of the logger and you will have access to
all the program settings of the logger as well as PDF file with readings and graph.
QUESTIONS:
Please contact:
Escort Cold Chain Solutions SA
Via Gordemo 28, 6596 Gordola, Switzerland:
Tel +41 91 7452138; Fax: +41 91 7450708;
email: [email protected]
I-PLUG pdf
1.0 Dec.14
Page 4 / 4

advertisement

Key Features

  • Single use
  • USB interface
  • Temperature logging
  • Configurable log cycle
  • Alarm thresholds
  • Track and trace in web portal
  • No software needed

Frequently Answers and Questions

How do I start the device?
Press the START button until all 4 LEDs flash, then release the button when the GREEN LED is active.
How do I stop the device?
You can stop the device either by pressing the STOP button for 6 seconds until the RED LED is active and fixed or by connecting the device to a computer's USB port.
How do I configure the device?
The device comes pre-configured, but you can change the settings by plugging it into a computer before activating it and using the I-PLUG pdf manager software. You can download the software from the 'Downloads' section of the ECCS website at www.escortcoldchain.com.
What do the LEDs indicate?
The LEDs indicate the device status, such as recording, stopped, alarm reached, and low battery.
How do I track and trace the data?
Download the I-PLUG Connector software from the ECCS website. Once the data is downloaded, the software automatically sends it to the web portal, where you can view the data, generate reports, and analyze the temperature readings.