ECCS I-PLUG pdf Temperature Data Logger User Manual
The ECCS I-PLUG pdf is a single-use USB temperature data logger that records temperature measurements over a set period of time. It is designed to monitor the temperature of sensitive goods during transportation and storage. The device features a range of configurable settings such as: recording interval, alarm thresholds, and user-defined text. The device can be used in a variety of applications, such as the transportation of pharmaceuticals, food, and other temperature-sensitive products.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
ECCS I-PLUG pdf Single use USB Temperature Data Logger ECCS I-PLUG pdf USER MANUAL Company: ECCS – Escort Cold Chain Solutions SA Brand Name: I-PLUG pdf logger Product Description: Single use USB Temperature Data Logger FEATURES AND ADVANTAGES: • Dimensions: 7.5 cm x 4 cm x 0.5 cm • Temperature measurement range: -40 to +65 Degrees Celsius • Temperature resolution: 0.01 °C • Data storage capacity: 8000 Measurements • Log cycle: 5 days to 90 days • Data Sampling Interval: 1 second to 27 minutes • No software needed • Track and trace of settings, graph and readings in web portal. STANDARD AVAILABLE DURATIONS: 1 2 3 4 5 6 7 Total Time (Days) 5 10 30 40 60 75 90 Log Cycle (Minutes) 1 2 6 8 11 14 17 APPEARENCE OF I-PLUG pdf : I-PLUG pdf 1.0 Dec.14 Page 1 / 4 ECCS I-PLUG pdf Single use USB Temperature Data Logger How does it work : How to START it ? When you are ready to use I-PLUG pdf Logger, press the START button till the 4 LED’s flash – release only when the GREEN LED is active. The GREEN LED will remain active during the first 2 hours of recording. After the first 2 hours of recording, press briefly any of the two buttons to get the device status (see meanings bellow) How to STOP it ? I-PLUG pdf is programmed with a typical trip duration, and will keep recording until the end of this trip duration There are two different ways to STOP the device before the end of the trip duration : - Press the STOP button during 6 seconds till the 4 LED’s flash – release only when the RED LED is active and fixed. Connect the device on the USB port of the computer Once stopped, The RED LED will remain active till the end of the battery life. CONFIGURING THE I-PLUG pdf The I-PLUG pdf data logger comes already configured to standard formats according to your purchase. The standard trip duration is 90 DAYS. Nevertheless if you wish to change the configuration like changing the recording time, adding alarms or entering text in the device memory, you just need to plug it in a computer before being activated and use the I-PLUG pdf manager software. Get the I-PLUG pdf manager software in the “Downloads” section of our website www.escortcoldchain.com I-PLUG pdf 1.0 Dec.14 Page 2 / 4 ECCS I-PLUG pdf Single use USB Temperature Data Logger USING THE LEDS INDICATORS The LEDS will give you valuable information of the conditions of your shipment as indicated in below table. If you press START or STOP button briefly, while I-PLUG+ works, LEDS will blink. Here the meanings: APPEARENCE OF I-PLUG pdf MEANING when any button pressed Blinking Green : This confirms that the device is already started. NOTE : there is a fixed green LED during the first 2 hours of recording. Fixed Red : Device is in a STOP position Blinking Blue : low alarm has been reached Fixed Blue : ultra low alarm has been reached Blinking Orange : high alarm has been reached Fixed Orange : ultra high alarm has been reached NOTE : orange LED automatically blinks every time the device makes a temperature record. I-PLUG pdf 1.0 Dec.14 Page 3 / 4 ECCS I-PLUG pdf Single use USB Temperature Data Logger 4 blinking LED : device is not started CONNECTING TO THE COMPUTER: As soon as the I-PLUG pdf is connected to the PC via the USB port the computer will automatically detect the device. The I-PLUG pdf will be detected by the computer as a USB disk drive and will be recognized without any driver installation process. USING THE I-PLUG CONNECTOR FOR ADDED BENEFITS : Download the free I-PLUG Connetor software on www.escortcoldchain.com or www.ipluglogger.com click the button “DOWNLOAD I-PLUG pdf Connector”. You do not need to register to download the software. TRACK AND TRACE OF THE I-PLUG pdf: Once you have downloaded the recordings from the I-PLUG pdf logger the I-PLUG Connector will automatically send the data to the web, and allow you to extract data in excel files, zoom on the graph and many other features. Devices connected with the I-PLUG pdf Connector will automatically send to the web the temperature recordings they have in memory. To access the WEB TRACKING PORTAL go to the website www.escortcoldchain.com or www.ipluglogger.com and click on the icon TRACK and TRACE I-PLUG pdf LOGGER, then write on the field SEARCH the serial number of the logger and you will have access to all the program settings of the logger as well as PDF file with readings and graph. QUESTIONS: Please contact: Escort Cold Chain Solutions SA Via Gordemo 28, 6596 Gordola, Switzerland: Tel +41 91 7452138; Fax: +41 91 7450708; email: [email protected] I-PLUG pdf 1.0 Dec.14 Page 4 / 4
advertisement
Key Features
- Single use
- USB interface
- Temperature logging
- Configurable log cycle
- Alarm thresholds
- Track and trace in web portal
- No software needed