Mitsubishi Electric GT1455 QTBD(E), GT1450 QMBD(E), QLBD(E) GOT General Description

Mitsubishi Electric GT1455 QTBD(E), GT1450 QMBD(E), QLBD(E) GOT General Description

GOT touch screen GT1455-QTBD(E), GT1450-QMBD(E), GT1450-QLBD(E) are touch screen monitors intended for use in industrial automation applications. They are designed to provide operators with a user-friendly interface for monitoring and controlling industrial processes. The devices have a variety of features that make them suitable for a wide range of applications, including machine monitoring, process control, and data logging.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Mitsubishi Electric GT1455 QTBD(E), GT1450 QMBD(E), GT1450 QLBD(E) General Description | Manualzz

JY997D43901F

GT1455-QTBD(E), GT1450-QMBD(E)

GT1450-QLBD(E)

GT14 General Description

Manual Number

Date

JY997D43901F

December 2015

This manual describes the part names, dimensions, mounting, and specifications of the product. Before use, read this manual and manuals of relevant products fully to acquire proficiency in handling and operating the product. Make sure to learn all the product information, safety information, and precautions.

And, store this manual in a safe place so that you can take it out and read it whenever necessary. Always forward it to the end user.

Registration

Ethernet is a trademark of Xerox Corporation in the United States. The company name and the product name to be described in this manual are the registered trademarks or trademarks of each company.

Effective December 2015

Specifications are subject to change without notice.

 2011 MITSUBISHI ELECTRIC CORPORATION

Safety Precaution

(Read these precautions before using.)

Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly.

The precautions given in this manual are concerned with this product.

In this manual, the safety precautions are ranked as "WARNING" and

"CAUTION".

Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.

Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage.

Depending on circumstances, procedures indicated by "CAUTION" may also be linked to serious results.

In any case, it is important to follow the directions for usage.

DESIGN PRECAUTIONS

 Some failures of the GOT or cable may keep the outputs on or off.

An external monitoring circuit should be provided to check for output signals which may lead to a serious accident.

Not doing so can cause an accident due to false output or malfunction.

 If a communication fault (including cable disconnection) occurs during monitoring on the GOT, communication between the GOT and PLC CPU is suspended and the GOT becomes inoperative.

A system where the GOT is used should be configured to perform any significant operation to the system by using the switches of a device other than the GOT on the assumption that a GOT communication fault will occur.

Not doing so can cause an accident due to false output or malfunction.

 Do not use the GOT as the warning device that may cause a serious accident. An independent and redundant hardware or mechanical interlock is required to configure the device that displays and outputs serious warning.

Failure to observe this instruction may result in an accident due to incorrect output or malfunction.

 Incorrect operation of the touch switch(s) may lead to a serious accident if the

GOT backlight is gone out. When the GOT backlight goes out, the POWER

LED flickers (green/orange) and the display section turns black and causes the monitor screen to appear blank, while the input of the touch switch(s) remains active. This may confuse an operator in thinking that the GOT is in

"screensaver" mode, who then tries to release the GOT from this mode by touching the display section, which may cause a touch switch to operate.

Note that the following occurs on the GOT when the backlight goes out.

- The POWER LED flickers (green/orange) and the monitor screen appears blank

 The display section is an analog-resistive type touch panel.

If you touch the display section simultaneously in 2 points or more, the switch that is located around the center of the touched point, if any, may operate.

Do not touch the display section in 2 points or more simultaneously.

Doing so may cause an accident due to incorrect output or malfunction.

 When programs or parameters of the controller (such as a PLC) that is monitored by the GOT are changed, be sure to reset the GOT or shut off the power of the GOT at the same time.

Not doing so can cause an accident due to false output or malfunction.

DESIGN PRECAUTIONS

 Do not bundle the control and communication cables with main-circuit, power or other wiring.

Run the above cables separately from such wiring and keep them a minimum of

100mm (3.94in.) apart.Not doing so noise can cause a malfunction.

 Do not press the GOT display section with a pointed material as a pen or driver.

Doing so can result in a damage or failure of the display section.

 When using the GOT with Ethernet connection, available IP addresses are restricted depending on the system configuration.

- When connecting two or more GOT units to the Ethernet network:

Do not specify the IP address "192.168.0.18" to the GOT or any connected equipment.

- When connecting one GOT unit to the Ethernet network:

Do not specify the IP address "192.168.0.18" to any connected equipment other than the GOT.

If the IP address "192.168.0.18" is specified in the above system configuration,

IP address overlap occurs when the GOT is started up, and adverse effect may be given to communication in the equipment in which the IP address

"192.168.0.18" is set. Operation executed at IP address overlap varies depending on the equipment and system.

 Turn on the power of the connected equipment and network equipment, and make them ready for communication before connecting them to the GOT.

If the connected equipment and network equipment are not ready for communication, a communication error may occur in the GOT.

MOUNTING PRECAUTIONS

 Be sure to shut off all phases of the external power supply used by the system before mounting or removing the GOT to/from the panel.

Not doing so can cause the unit to fail or malfunction.

MOUNTING PRECAUTIONS

 Use the GOT in the environment that satisfies the general specifications described in this manual. Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration.

 When mounting the GOT to the control panel, tighten the mounting screws in the specified torque range. Undertightening can cause the GOT to drop, short circuit or malfunction, and deteriorate the waterproof effect and oilproof effect.

Overtightening can cause a drop, short circuit or malfunction due to the damage of the screws or the GOT, and deteriorate the waterproof effect and oilproof effect due to distortion of the protective cover for oil, GOT or panel.

 Never drop cutting chips and electric wire chips into the ventilation window of the

GOT when you drill screw holes or perform wiring.

Otherwise, fire, failure or malfunction may be caused.

 When inserting/removing a SD card into/from the GOT, turn the SD card access switch off in advance. Failure to do so may corrupt data within the SD card.

 When removing a SD card from the GOT, make sure to support the SD card by hand, as it may pop out. Failure to do so may cause the SD card to drop from the

GOT and break.

 When installing a USB memory to the GOT, make sure to install the USB memory to the USB interface firmly.

Failure to do so may cause a malfunction due to poor contact.

 Before removing the USB memory from the GOT, operate the utility screen for removal. After the successful completion dialog box is displayed, remove the memory by hand carefully. Failure to do so may cause the USB memory to drop, resulting in a damage or failure of the memory.

 Operate and store the GOT in environments without direct sunlight, high temperature, dust, humidity, and vibrations.

 When using the GOT in the environment of oil or chemicals, use the protective cover for oil.

Failure to do so may cause failure or malfunction due to the oil or chemical entering into the GOT.

WIRING PRECAUTIONS

 Be sure to shut off all phases of the external power supply used by the system before wiring. Failure to do so may result in an electric shock, product damage or malfunctions.

 Please make sure to ground FG terminal of the GOT power supply section by applying 100 or less which is used exclusively for the GOT. Not doing so may cause an electric shock or malfunction.

 Correctly wire the GOT power supply section after confirming the rated voltage and terminal arrangement of the product. Not doing so can cause a fire or failure.

 Tighten the terminal screws of the GOT power supply section in the specified torque range. Undertightening can cause a short circuit or malfunction.

Overtightening can cause a short circuit or malfunction due to the damage of the screws or the GOT.

 Exercise care to avoid foreign matter such as chips and wire offcuts entering the

GOT. Not doing so can cause a fire, failure or malfunction.

WIRING PRECAUTIONS

 The cables connected to the unit must be run in ducts or clamped.

Not doing so can cause the unit or cable to be damaged due to the dangling, motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault.

 When unplugging the cable connected to the unit, do not hold and pull the cable portion.

Doing so can cause the unit or cable to be damaged or can cause a malfunction due to a cable connection fault.

 Plug the communication cable into the connector of the connected unit and tighten the mounting and terminal screws in the specified torque range.

Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit.

TEST OPERATION

PRECAUTIONS

 Before performing the test operations of the user creation monitor screen (such as turning ON or OFF bit device, changing the word device current value, changing the settings or current values of the timer or counter, and changing the buffer memory current value), read through the manual carefully and make yourself familiar with the operation method.

During test operation, never change the data of the devices which are used to perform significant operation for the system. False output or malfunction can cause an accident.

STARTUP/MAINTENANCE

PRECAUTIONS

 When power is on, do not touch the terminals.

Doing so can cause an electric shock or malfunction.

 Connect the battery correctly. Do not discharge, disassemble, heat, short, solder or throw the battery into the fire. Incorrect handling may cause the battery to generate heat, burst or take fire, resulting in injuries or fires.

 Before starting cleaning or terminal screw retightening, always switch off the power externally in all phases. Not switching the power off in all phases can cause a unit failure or malfunction. Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit.

STARTUP/MAINTENANCE

PRECAUTIONS

 Do not disassemble or modify the unit.

Doing so can cause a failure, malfunction, injury or fire.

 Do not touch the conductive and electronic parts of the unit directly.

Doing so can cause a unit malfunction or failure.

 The cables connected to the unit must be run in ducts or clamped.

Not doing so can cause the unit or cable to be damaged due to the dangling, motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault.

 When unplugging the cable connected to the unit, do not hold and pull the cable portion. Doing so can cause the unit or cable to be damaged or can cause a malfunction due to a cable connection fault.

 Do not drop or apply any impact to the battery.If any impact has been applied, discard the battery and never use it.

The battery may be damaged by the drop or impact.

 Before touching the unit, always touch grounded metal, etc. to discharge static electricity from human body, etc.

Not doing so can cause the unit to fail or malfunction.

 Replace battery with GT11-50BAT by Mitsubishi electric Co. only.

Use of another battery may present a risk of fire or explosion.

 Dispose of used battery promptly.

Keep away from children. Do not disassemble and do not dispose of in fire.

DISPOSAL PRECAUTIONS

 When disposing of the product, handle it as industrial waste.

 When disposing of batteries, separate them from other wastes according to the local regulations.

(For details of the battery directive in EU member states, refer GOT User's

Manual.)

TOUCH PANEL

PRECAUTIONS

 For the analog-resistive film type touch panels, normally the adjustment is not required.

However, the difference between a touched position and the object position may occur as the period of use elapses.

When any difference between a touched position and the object position occurs, execute the touch panel calibration.

 When any difference between a touched position and the object position occurs, other object may be activated.

This may cause an unexpected operation due to incorrect output or malfunction.

TRANSPORTATION

PRECAUTIONS

 When transporting lithium batteries, make sure to treat them based on the transport regulations.

(Refer to User's Manual for details of the regurated models.)

 Before transporting the GOT, turn the GOT power on and check that the battery voltage status is normal on the Time setting & display screen (utilities screen). In addition, confirm that the adequate battery life remains on the rating plate.

Transporting the GOT with the low battery voltage or the battery the reached battery life may unstabilize the backup data unstable during transportation.

 Make sure to transport the GOT main unit and/or relevant unit(s) in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of this manual, as they are precision devices. Failure to do so may cause the unit to fail.

Check if the unit operates correctly after transportation.

Associated Manuals

The following manuals are relevant to this product. When these loose manuals are required, please consult with our local distributor.

Manual name Contents

Manual Number

(Model Code)

GT14 User’s Manual

(sold separately)

D e s c r i b e s t h e G T 1 4 h a r d w a r e relevant content such as part names, external dimensions, mounting, power supply wiring, specifications, and introduction to option devices

GT Designer3

Version1 Screen

Design Manual

(For GOT1000

S e r i e s )

(Fundamentals)

1/2, 2/2

(sold separately) *1

GT Designer3

Version1 Screen

Design Manual

(For GOT1000

Series) (Functions)

1/2, 2/2

(sold separately) *1

D e s c r i b e s m e t h o d s o f t h e G T

Designer3 installation operation, basic operation for drawing and transmitting data to GOT1000 series

Describes specifications and settings of the object functions used in GT

Designer3

JY997D44801

(09R823)

SH-080866ENG

(1D7MB9)

SH-080867ENG

(1D7MC1)

*1 Stored in the GT Works3/GT Designer3 in PDF format.

For details of a PLC to be connected, refer to the PLC user's manual respectively.

Bundled Items

Product

Name

Model Name

GOT

Specifications

GT1455-QTBDE

GT1455-QTBD

GT1450-QMBDE

GT1450-QMBD

GT1450-QLBDE

GT1450-QLBD

5.7" diagonal [320  240 dots], TFT color (65536 colors), built-in battery and Ethernet interface

5.7" diagonal [320  240 dots], TFT color (65536 colors), built-in battery

5.7" diagonal [320  240 dots], TFT monochrome

(black/white), built-in battery and Ethernet interface

5.7" diagonal [320  240 dots], TFT monochrome

(black/white), built-in battery

5.7" diagonal [320  240 dots], STN monochrome

(black/white), built-in battery and Ethernet interface

5.7" diagonal [320  240 dots], STN monochrome

(black/white), built-in battery

Bundled item

Mounting brackets

Mounting screws: M4 x 35mm (1.38")

Dust-/Water-proof packing

GT14 General Description (This manual)

1. Features

1) Improved monitoring performance and connectivity to FA devices

- Multiple languages are displayed using the Unicode2.1-compatible fonts and beautiful characters are drawn using the TrueType and high quality fonts.

- Two types of display modes are provided: 65536-colors display and monochrome display.

In the monochrome display, 16 scales are used to improve the display.

A fine and beautiful full-color display which shows even small characters clearly, is enabled by adopting the high intensity, wide viewing angle and high definition TFT color LCD. (Also compatible with digital screen displays with 65536 colors, BMP, etc.)

- High-speed monitoring through high-speed serial communication at 115.2 kbps maximum or through Ethernet connection.

- High speed display and high speed touch switch response.

2) More efficient GOT operations including screen design, startup, adjustment, management and maintenance works

- The 9MB built-in flash memory is included as standard.

- SD card interface is included as standard.

- RS-232 interface is included as standard.

- RS-422/485 interface is included as standard.

- USB interface (host/device) are included as standard.

- Ethernet interface is included. (in some models)

3) Enhanced support of FA setup tools

- PLC program transfer and monitoring are possible via the personal computer that is connected to the GOT if connected directly to the A, QnA,

L, Q, or FX series of the PLC CPU (FA transparent function).

2. Part Name

2.1 Front

4)

Quantity

4

4

1

1

2.2 Back/Bottom

1)

2)

17)

4)

11) 12) 3)

5) 7) 8)

6)

Battery cover opened

14)

9)

13)

16)

10) 15)

17)

1) 2)

3)

5) 6)

No

6)

Name

1) Display screen

2) Touch panel

3) POWER LED

4) Logo label

5) USB interface

Specifications

Displays the utility screen and the user creation screen.

GT1455-QTBD(E):320 240 dots, TFT color liquid crystal

GT1450-QMBD(E):320 240 dots, TFT monochrome

(white/black) liquid crystal, 16 scales

GT1450-QLBD(E):320 240 dots, STN monochrome

(white/black) liquid crystal, 16 scales

For operating the touch switches in the utility screen and the user creation screen

Lit in green: Power is correctly supplied

Lit in orange: Screen saving

Blinking in orange/green: Blown backlight bulb

Not lit: Power is not supplied

Removable

USB interface for connecting a personal computer

(Device)

O S i n s t a l l a t i o n , p r o j e c t d a t a d o w n l o a d , FA transparent

USB environmental protection cover

Opens/Closes when the USB interface is used.

For the PC connection, refer to the following.

GT14 User’s Manual

No.

1)

2)

3)

4)

5)

6)

7)

8)

9)

10)

11)

12)

13)

14)

Name

RS-232 interface

RS-422/485 interface

USB interface

Hole for preventing

USB cable disconnection

For communicating with controller or personal computer

(D-sub 9-pin male)

Specifications

For communicating with controller (D-sub 9-pin female)

For data transfer, data storage USB interface (Host)

Hole for fixing the USB cable with a cable tie (such as

Insulock) to prevent disconnection

Rating plate

(nameplate)

SD card interface

SD card access LED

--

Interface for installing the SD card to GOT

SD card access switch

Lit: SD card accessed

Not lit: SD card not accessed

Switch for prohibiting access to SD card before removing the SD card from the GOT

ON: SD card being accessed (SD card removal prohibited)

OFF: No access to SD card (SD card removal possible)

Battery

Battery cover

GT11-50BAT battery for storing clock data, alarm history and recipe data

Open or close when replacing the battery.

Opened and closed when the terminating resistor is changed over

Power terminal

Power terminal and FG terminal

(for power supply (24VDC) to GOT and grounding)

Power terminal cover

Open or close when connecting a power terminal.

(Color: transparent)

Hardware reset switch (Use an isolated rod to operate.) Reset switch

Terminating resistor selector switch

Terminating resistor selector switch of RS-422/485

(330 /OPEN/110)

15)

Ethernet communication status LED

SD RD: Turns on in green during data communication,

100M:Turns on in green during 100Mbps transmission.

16)

17)

Ethernet interface

Hole for unit installation fitting

For connecting the equipment through Ethernet

(RJ-45 connector)

Hole for the inserting installation fittings (accessory) during the GOT installation to the panel

(4 holes at top and bottom)

For the connection to the controller (PLC, microcomputer board, bar code reader,

RFID, etc) or PC, refer to the following.

GT14 User’s Manual

3. Specifications

3.1 General Specifications

Operating ambient temperature

Item Specifications

Display section 0 to 50 C

Other than display section 0 to 55 C (When mounted horizontally), 0 to 50C (When mounted vertically)

Storage ambient temperature

Operating ambient humidity

Storage ambient humidity

-20 to 60 C

10 to 90% RH, non-condensing (STN liquid crystal type to be stored at or below 39 C WBT.)

10 to 90% RH, non-condensing (STN liquid crystal type to be stored at or below 39 C WBT.)

Vibration resistance

Shock resistance

Operating atmosphere

Conforms to JIS

B3502 and

IEC61131-2

Under intermittent vibration

Under continuous vibration

Frequency

5 to 8.4Hz

8.4 to 150Hz

5 to 8.4Hz

8.4 to 150Hz

Acceleration

--

9.8m/s

--

4.9m/s

2

2

Half-amplitude

3.5mm

Conforms to JIS B3502, IEC 61131-2 (147 m/s 2 , 3 times each in X, Y and Z directions)

--

1.75mm

--

Sweep Count

10 times each in X,

Y and Z directions

Must be free of lamp black, corrosive gas, flammable gas, or excessive amount of electro conductive dust particles and must be no direct sunlight. (Same as for saving)

Operating altitude *1

Installation location

Overvoltage category *2

Pollution degree

Cooling method

*3

2000 m (6562 ft) max.

Inside control panel

 or less

2 or less

Self-cooling

*1 Do not use or store the GOT under pressure higher than the atmospheric pressure of altitude 0m (0ft.). Failure to observe this instruction may cause a malfunction.

When the air inside the control panel is purged by pressurization, the surface sheet may be lifted by high pressure. As a result, the touch panel may be difficult to press, and the sheet may be peeled off.

*2 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within the premises.

Category  applies to equipment for which electrical power is supplied from fixed facilities.

The surge voltage withstand level for up to the raged voltage of 300 V is 2500 V.

*3 This index indicates the degree to which conductive material is generated in the environment where the equipment is used.

In pollution degree 2, only non-conductive pollution occurs but temporary conductivity may be produced due to condensation.

3.2 Performance Specifications

Display section *1

Backlight

To u c h panel

*4

Type

Item

Screen size

Resolution

Display size

Display character

Display color

GT1455-QTBD(E)

TFT color liquid crystal

5.7"

320  240 dots

W115(4.53)  H86(3.39)[mm](inch) (Horizontal format)

16-dot standard font: 20 characters

Specifications

GT1450-QMBD(E)

TFT monochrome (white/black)

liquid crystal

GT1450-QLBD(E)

STN monochrome (white/black)

liquid crystal

 15 lines, 12-dot standard font: 26 characters  20 lines

Display angle *2

Contrast adjustment

Intensity of LCD only

Intensity adjustment

Life

65536 colors Monochrome (white/black), 16 scales

Left/Right: 80 degrees, Top: 80 degrees, Bottom: 60 degrees (Horizontal format)

Left/Right: 45 degrees,

Top: 20 degrees,

Bottom: 40 degrees (Horizontal format)

32-level adjustmen --

400[cd/m

2

] 300[cd/m

2

]

8-level adjustment

Approx. 50,000h. (Time for display intensity to become 1/5 at operating ambient temperature of 25 C)

Life

Type

Key size

N u m b e r o f p o i n ts t o u c h e d simultaneously

LED (irreplaceable by a user) Backlight off/screen saving time can be set.

*3

Approx. 70,000h or longer (Time for display intensity reaches 50% at the operating ambient temperature of 25

Analog resistive film touch panel

Minimum 2  2 dots (per key)

Simultaneous presses not allowed. (Only 1 point can be touched.)

C)

Memory

Battery

Life

C drive *5

1 million times or more (operating force 0.98N max.)

Flash memory (Internal), for storing project data (9Mbytes) and OS

D drive

Life (Number of write times) 100,000 times

SRAM (Internal), 512kbytes (battery backup)

Type

GT11-50BAT lithium battery

Magnesium maganese dioxide lithium primary battery

Backup target

Life

Clock data, alarm history, recipe data, time action setting value, advanced alarm/advanced recipe, logging, hardcopy and

SRAM user area

Approx. 5 years (Operating ambient temperature of 25 C)

JY997D43901F

GT1455-QTBD(E), GT1450-QMBD(E)

GT1450-QLBD(E)

GT14 General Description

Manual Number

Date

JY997D43901F

December 2015

This manual describes the part names, dimensions, mounting, and specifications of the product. Before use, read this manual and manuals of relevant products fully to acquire proficiency in handling and operating the product. Make sure to learn all the product information, safety information, and precautions.

And, store this manual in a safe place so that you can take it out and read it whenever necessary. Always forward it to the end user.

Registration

Ethernet is a trademark of Xerox Corporation in the United States. The company name and the product name to be described in this manual are the registered trademarks or trademarks of each company.

Effective December 2015

Specifications are subject to change without notice.

 2011 MITSUBISHI ELECTRIC CORPORATION

Safety Precaution

(Read these precautions before using.)

Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly.

The precautions given in this manual are concerned with this product.

In this manual, the safety precautions are ranked as "WARNING" and

"CAUTION".

Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.

Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage.

Depending on circumstances, procedures indicated by "CAUTION" may also be linked to serious results.

In any case, it is important to follow the directions for usage.

DESIGN PRECAUTIONS

 Some failures of the GOT or cable may keep the outputs on or off.

An external monitoring circuit should be provided to check for output signals which may lead to a serious accident.

Not doing so can cause an accident due to false output or malfunction.

 If a communication fault (including cable disconnection) occurs during monitoring on the GOT, communication between the GOT and PLC CPU is suspended and the GOT becomes inoperative.

A system where the GOT is used should be configured to perform any significant operation to the system by using the switches of a device other than the GOT on the assumption that a GOT communication fault will occur.

Not doing so can cause an accident due to false output or malfunction.

 Do not use the GOT as the warning device that may cause a serious accident. An independent and redundant hardware or mechanical interlock is required to configure the device that displays and outputs serious warning.

Failure to observe this instruction may result in an accident due to incorrect output or malfunction.

 Incorrect operation of the touch switch(s) may lead to a serious accident if the

GOT backlight is gone out. When the GOT backlight goes out, the POWER

LED flickers (green/orange) and the display section turns black and causes the monitor screen to appear blank, while the input of the touch switch(s) remains active. This may confuse an operator in thinking that the GOT is in

"screensaver" mode, who then tries to release the GOT from this mode by touching the display section, which may cause a touch switch to operate.

Note that the following occurs on the GOT when the backlight goes out.

- The POWER LED flickers (green/orange) and the monitor screen appears blank

 The display section is an analog-resistive type touch panel.

If you touch the display section simultaneously in 2 points or more, the switch that is located around the center of the touched point, if any, may operate.

Do not touch the display section in 2 points or more simultaneously.

Doing so may cause an accident due to incorrect output or malfunction.

 When programs or parameters of the controller (such as a PLC) that is monitored by the GOT are changed, be sure to reset the GOT or shut off the power of the GOT at the same time.

Not doing so can cause an accident due to false output or malfunction.

DESIGN PRECAUTIONS

 Do not bundle the control and communication cables with main-circuit, power or other wiring.

Run the above cables separately from such wiring and keep them a minimum of

100mm (3.94in.) apart.Not doing so noise can cause a malfunction.

 Do not press the GOT display section with a pointed material as a pen or driver.

Doing so can result in a damage or failure of the display section.

 When using the GOT with Ethernet connection, available IP addresses are restricted depending on the system configuration.

- When connecting two or more GOT units to the Ethernet network:

Do not specify the IP address "192.168.0.18" to the GOT or any connected equipment.

- When connecting one GOT unit to the Ethernet network:

Do not specify the IP address "192.168.0.18" to any connected equipment other than the GOT.

If the IP address "192.168.0.18" is specified in the above system configuration,

IP address overlap occurs when the GOT is started up, and adverse effect may be given to communication in the equipment in which the IP address

"192.168.0.18" is set. Operation executed at IP address overlap varies depending on the equipment and system.

 Turn on the power of the connected equipment and network equipment, and make them ready for communication before connecting them to the GOT.

If the connected equipment and network equipment are not ready for communication, a communication error may occur in the GOT.

MOUNTING PRECAUTIONS

 Be sure to shut off all phases of the external power supply used by the system before mounting or removing the GOT to/from the panel.

Not doing so can cause the unit to fail or malfunction.

MOUNTING PRECAUTIONS

 Use the GOT in the environment that satisfies the general specifications described in this manual. Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration.

 When mounting the GOT to the control panel, tighten the mounting screws in the specified torque range. Undertightening can cause the GOT to drop, short circuit or malfunction, and deteriorate the waterproof effect and oilproof effect.

Overtightening can cause a drop, short circuit or malfunction due to the damage of the screws or the GOT, and deteriorate the waterproof effect and oilproof effect due to distortion of the protective cover for oil, GOT or panel.

 Never drop cutting chips and electric wire chips into the ventilation window of the

GOT when you drill screw holes or perform wiring.

Otherwise, fire, failure or malfunction may be caused.

 When inserting/removing a SD card into/from the GOT, turn the SD card access switch off in advance. Failure to do so may corrupt data within the SD card.

 When removing a SD card from the GOT, make sure to support the SD card by hand, as it may pop out. Failure to do so may cause the SD card to drop from the

GOT and break.

 When installing a USB memory to the GOT, make sure to install the USB memory to the USB interface firmly.

Failure to do so may cause a malfunction due to poor contact.

 Before removing the USB memory from the GOT, operate the utility screen for removal. After the successful completion dialog box is displayed, remove the memory by hand carefully. Failure to do so may cause the USB memory to drop, resulting in a damage or failure of the memory.

 Operate and store the GOT in environments without direct sunlight, high temperature, dust, humidity, and vibrations.

 When using the GOT in the environment of oil or chemicals, use the protective cover for oil.

Failure to do so may cause failure or malfunction due to the oil or chemical entering into the GOT.

WIRING PRECAUTIONS

 Be sure to shut off all phases of the external power supply used by the system before wiring. Failure to do so may result in an electric shock, product damage or malfunctions.

 Please make sure to ground FG terminal of the GOT power supply section by applying 100 or less which is used exclusively for the GOT. Not doing so may cause an electric shock or malfunction.

 Correctly wire the GOT power supply section after confirming the rated voltage and terminal arrangement of the product. Not doing so can cause a fire or failure.

 Tighten the terminal screws of the GOT power supply section in the specified torque range. Undertightening can cause a short circuit or malfunction.

Overtightening can cause a short circuit or malfunction due to the damage of the screws or the GOT.

 Exercise care to avoid foreign matter such as chips and wire offcuts entering the

GOT. Not doing so can cause a fire, failure or malfunction.

WIRING PRECAUTIONS

 The cables connected to the unit must be run in ducts or clamped.

Not doing so can cause the unit or cable to be damaged due to the dangling, motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault.

 When unplugging the cable connected to the unit, do not hold and pull the cable portion.

Doing so can cause the unit or cable to be damaged or can cause a malfunction due to a cable connection fault.

 Plug the communication cable into the connector of the connected unit and tighten the mounting and terminal screws in the specified torque range.

Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit.

TEST OPERATION

PRECAUTIONS

 Before performing the test operations of the user creation monitor screen (such as turning ON or OFF bit device, changing the word device current value, changing the settings or current values of the timer or counter, and changing the buffer memory current value), read through the manual carefully and make yourself familiar with the operation method.

During test operation, never change the data of the devices which are used to perform significant operation for the system. False output or malfunction can cause an accident.

STARTUP/MAINTENANCE

PRECAUTIONS

 When power is on, do not touch the terminals.

Doing so can cause an electric shock or malfunction.

 Connect the battery correctly. Do not discharge, disassemble, heat, short, solder or throw the battery into the fire. Incorrect handling may cause the battery to generate heat, burst or take fire, resulting in injuries or fires.

 Before starting cleaning or terminal screw retightening, always switch off the power externally in all phases. Not switching the power off in all phases can cause a unit failure or malfunction. Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit.

STARTUP/MAINTENANCE

PRECAUTIONS

 Do not disassemble or modify the unit.

Doing so can cause a failure, malfunction, injury or fire.

 Do not touch the conductive and electronic parts of the unit directly.

Doing so can cause a unit malfunction or failure.

 The cables connected to the unit must be run in ducts or clamped.

Not doing so can cause the unit or cable to be damaged due to the dangling, motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault.

 When unplugging the cable connected to the unit, do not hold and pull the cable portion. Doing so can cause the unit or cable to be damaged or can cause a malfunction due to a cable connection fault.

 Do not drop or apply any impact to the battery.If any impact has been applied, discard the battery and never use it.

The battery may be damaged by the drop or impact.

 Before touching the unit, always touch grounded metal, etc. to discharge static electricity from human body, etc.

Not doing so can cause the unit to fail or malfunction.

 Replace battery with GT11-50BAT by Mitsubishi electric Co. only.

Use of another battery may present a risk of fire or explosion.

 Dispose of used battery promptly.

Keep away from children. Do not disassemble and do not dispose of in fire.

DISPOSAL PRECAUTIONS

 When disposing of the product, handle it as industrial waste.

 When disposing of batteries, separate them from other wastes according to the local regulations.

(For details of the battery directive in EU member states, refer GOT User's

Manual.)

TOUCH PANEL

PRECAUTIONS

 For the analog-resistive film type touch panels, normally the adjustment is not required.

However, the difference between a touched position and the object position may occur as the period of use elapses.

When any difference between a touched position and the object position occurs, execute the touch panel calibration.

 When any difference between a touched position and the object position occurs, other object may be activated.

This may cause an unexpected operation due to incorrect output or malfunction.

TRANSPORTATION

PRECAUTIONS

 When transporting lithium batteries, make sure to treat them based on the transport regulations.

(Refer to User's Manual for details of the regurated models.)

 Before transporting the GOT, turn the GOT power on and check that the battery voltage status is normal on the Time setting & display screen (utilities screen). In addition, confirm that the adequate battery life remains on the rating plate.

Transporting the GOT with the low battery voltage or the battery the reached battery life may unstabilize the backup data unstable during transportation.

 Make sure to transport the GOT main unit and/or relevant unit(s) in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of this manual, as they are precision devices. Failure to do so may cause the unit to fail.

Check if the unit operates correctly after transportation.

Associated Manuals

The following manuals are relevant to this product. When these loose manuals are required, please consult with our local distributor.

Manual name Contents

Manual Number

(Model Code)

GT14 User’s Manual

(sold separately)

D e s c r i b e s t h e G T 1 4 h a r d w a r e relevant content such as part names, external dimensions, mounting, power supply wiring, specifications, and introduction to option devices

GT Designer3

Version1 Screen

Design Manual

(For GOT1000

S e r i e s )

(Fundamentals)

1/2, 2/2

(sold separately) *1

GT Designer3

Version1 Screen

Design Manual

(For GOT1000

Series) (Functions)

1/2, 2/2

(sold separately) *1

D e s c r i b e s m e t h o d s o f t h e G T

Designer3 installation operation, basic operation for drawing and transmitting data to GOT1000 series

Describes specifications and settings of the object functions used in GT

Designer3

JY997D44801

(09R823)

SH-080866ENG

(1D7MB9)

SH-080867ENG

(1D7MC1)

*1 Stored in the GT Works3/GT Designer3 in PDF format.

For details of a PLC to be connected, refer to the PLC user's manual respectively.

Bundled Items

Product

Name

Model Name

GOT

Specifications

GT1455-QTBDE

GT1455-QTBD

GT1450-QMBDE

GT1450-QMBD

GT1450-QLBDE

GT1450-QLBD

5.7" diagonal [320  240 dots], TFT color (65536 colors), built-in battery and Ethernet interface

5.7" diagonal [320  240 dots], TFT color (65536 colors), built-in battery

5.7" diagonal [320  240 dots], TFT monochrome

(black/white), built-in battery and Ethernet interface

5.7" diagonal [320  240 dots], TFT monochrome

(black/white), built-in battery

5.7" diagonal [320  240 dots], STN monochrome

(black/white), built-in battery and Ethernet interface

5.7" diagonal [320  240 dots], STN monochrome

(black/white), built-in battery

Bundled item

Mounting brackets

Mounting screws: M4 x 35mm (1.38")

Dust-/Water-proof packing

GT14 General Description (This manual)

1. Features

1) Improved monitoring performance and connectivity to FA devices

- Multiple languages are displayed using the Unicode2.1-compatible fonts and beautiful characters are drawn using the TrueType and high quality fonts.

- Two types of display modes are provided: 65536-colors display and monochrome display.

In the monochrome display, 16 scales are used to improve the display.

A fine and beautiful full-color display which shows even small characters clearly, is enabled by adopting the high intensity, wide viewing angle and high definition TFT color LCD. (Also compatible with digital screen displays with 65536 colors, BMP, etc.)

- High-speed monitoring through high-speed serial communication at 115.2 kbps maximum or through Ethernet connection.

- High speed display and high speed touch switch response.

2) More efficient GOT operations including screen design, startup, adjustment, management and maintenance works

- The 9MB built-in flash memory is included as standard.

- SD card interface is included as standard.

- RS-232 interface is included as standard.

- RS-422/485 interface is included as standard.

- USB interface (host/device) are included as standard.

- Ethernet interface is included. (in some models)

3) Enhanced support of FA setup tools

- PLC program transfer and monitoring are possible via the personal computer that is connected to the GOT if connected directly to the A, QnA,

L, Q, or FX series of the PLC CPU (FA transparent function).

2. Part Name

2.1 Front

4)

Quantity

4

4

1

1

2.2 Back/Bottom

1)

2)

17)

4)

11) 12) 3)

5) 7) 8)

6)

Battery cover opened

14)

9)

13)

16)

10) 15)

17)

1) 2)

3)

5) 6)

No

6)

Name

1) Display screen

2) Touch panel

3) POWER LED

4) Logo label

5) USB interface

Specifications

Displays the utility screen and the user creation screen.

GT1455-QTBD(E):320 240 dots, TFT color liquid crystal

GT1450-QMBD(E):320 240 dots, TFT monochrome

(white/black) liquid crystal, 16 scales

GT1450-QLBD(E):320 240 dots, STN monochrome

(white/black) liquid crystal, 16 scales

For operating the touch switches in the utility screen and the user creation screen

Lit in green: Power is correctly supplied

Lit in orange: Screen saving

Blinking in orange/green: Blown backlight bulb

Not lit: Power is not supplied

Removable

USB interface for connecting a personal computer

(Device)

O S i n s t a l l a t i o n , p r o j e c t d a t a d o w n l o a d , FA transparent

USB environmental protection cover

Opens/Closes when the USB interface is used.

For the PC connection, refer to the following.

GT14 User’s Manual

No.

1)

2)

3)

4)

5)

6)

7)

8)

9)

10)

11)

12)

13)

14)

Name

RS-232 interface

RS-422/485 interface

USB interface

Hole for preventing

USB cable disconnection

For communicating with controller or personal computer

(D-sub 9-pin male)

Specifications

For communicating with controller (D-sub 9-pin female)

For data transfer, data storage USB interface (Host)

Hole for fixing the USB cable with a cable tie (such as

Insulock) to prevent disconnection

Rating plate

(nameplate)

SD card interface

SD card access LED

--

Interface for installing the SD card to GOT

SD card access switch

Lit: SD card accessed

Not lit: SD card not accessed

Switch for prohibiting access to SD card before removing the SD card from the GOT

ON: SD card being accessed (SD card removal prohibited)

OFF: No access to SD card (SD card removal possible)

Battery

Battery cover

GT11-50BAT battery for storing clock data, alarm history and recipe data

Open or close when replacing the battery.

Opened and closed when the terminating resistor is changed over

Power terminal

Power terminal and FG terminal

(for power supply (24VDC) to GOT and grounding)

Power terminal cover

Open or close when connecting a power terminal.

(Color: transparent)

Hardware reset switch (Use an isolated rod to operate.) Reset switch

Terminating resistor selector switch

Terminating resistor selector switch of RS-422/485

(330 /OPEN/110)

15)

Ethernet communication status LED

SD RD: Turns on in green during data communication,

100M:Turns on in green during 100Mbps transmission.

16)

17)

Ethernet interface

Hole for unit installation fitting

For connecting the equipment through Ethernet

(RJ-45 connector)

Hole for the inserting installation fittings (accessory) during the GOT installation to the panel

(4 holes at top and bottom)

For the connection to the controller (PLC, microcomputer board, bar code reader,

RFID, etc) or PC, refer to the following.

GT14 User’s Manual

3. Specifications

3.1 General Specifications

Operating ambient temperature

Item Specifications

Display section 0 to 50 C

Other than display section 0 to 55 C (When mounted horizontally), 0 to 50C (When mounted vertically)

Storage ambient temperature

Operating ambient humidity

Storage ambient humidity

-20 to 60 C

10 to 90% RH, non-condensing (STN liquid crystal type to be stored at or below 39 C WBT.)

10 to 90% RH, non-condensing (STN liquid crystal type to be stored at or below 39 C WBT.)

Vibration resistance

Shock resistance

Operating atmosphere

Conforms to JIS

B3502 and

IEC61131-2

Under intermittent vibration

Under continuous vibration

Frequency

5 to 8.4Hz

8.4 to 150Hz

5 to 8.4Hz

8.4 to 150Hz

Acceleration

--

9.8m/s

--

4.9m/s

2

2

Half-amplitude

3.5mm

Conforms to JIS B3502, IEC 61131-2 (147 m/s 2 , 3 times each in X, Y and Z directions)

--

1.75mm

--

Sweep Count

10 times each in X,

Y and Z directions

Must be free of lamp black, corrosive gas, flammable gas, or excessive amount of electro conductive dust particles and must be no direct sunlight. (Same as for saving)

Operating altitude *1

Installation location

Overvoltage category *2

Pollution degree

Cooling method

*3

2000 m (6562 ft) max.

Inside control panel

 or less

2 or less

Self-cooling

*1 Do not use or store the GOT under pressure higher than the atmospheric pressure of altitude 0m (0ft.). Failure to observe this instruction may cause a malfunction.

When the air inside the control panel is purged by pressurization, the surface sheet may be lifted by high pressure. As a result, the touch panel may be difficult to press, and the sheet may be peeled off.

*2 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within the premises.

Category  applies to equipment for which electrical power is supplied from fixed facilities.

The surge voltage withstand level for up to the raged voltage of 300 V is 2500 V.

*3 This index indicates the degree to which conductive material is generated in the environment where the equipment is used.

In pollution degree 2, only non-conductive pollution occurs but temporary conductivity may be produced due to condensation.

3.2 Performance Specifications

Display section *1

Backlight

To u c h panel

*4

Type

Item

Screen size

Resolution

Display size

Display character

Display color

GT1455-QTBD(E)

TFT color liquid crystal

5.7"

320  240 dots

W115(4.53)  H86(3.39)[mm](inch) (Horizontal format)

16-dot standard font: 20 characters

Specifications

GT1450-QMBD(E)

TFT monochrome (white/black)

liquid crystal

GT1450-QLBD(E)

STN monochrome (white/black)

liquid crystal

 15 lines, 12-dot standard font: 26 characters  20 lines

Display angle *2

Contrast adjustment

Intensity of LCD only

Intensity adjustment

Life

65536 colors Monochrome (white/black), 16 scales

Left/Right: 80 degrees, Top: 80 degrees, Bottom: 60 degrees (Horizontal format)

Left/Right: 45 degrees,

Top: 20 degrees,

Bottom: 40 degrees (Horizontal format)

32-level adjustmen --

400[cd/m

2

] 300[cd/m

2

]

8-level adjustment

Approx. 50,000h. (Time for display intensity to become 1/5 at operating ambient temperature of 25 C)

Life

Type

Key size

N u m b e r o f p o i n ts t o u c h e d simultaneously

LED (irreplaceable by a user) Backlight off/screen saving time can be set.

*3

Approx. 70,000h or longer (Time for display intensity reaches 50% at the operating ambient temperature of 25

Analog resistive film touch panel

Minimum 2  2 dots (per key)

Simultaneous presses not allowed. (Only 1 point can be touched.)

C)

Memory

Battery

Life

C drive *5

1 million times or more (operating force 0.98N max.)

Flash memory (Internal), for storing project data (9Mbytes) and OS

D drive

Life (Number of write times) 100,000 times

SRAM (Internal), 512kbytes (battery backup)

Type

GT11-50BAT lithium battery

Magnesium maganese dioxide lithium primary battery

Backup target

Life

Clock data, alarm history, recipe data, time action setting value, advanced alarm/advanced recipe, logging, hardcopy and

SRAM user area

Approx. 5 years (Operating ambient temperature of 25 C)

Built-in interface

RS-232

Item

RS-422/485

Ethernet

(Only in models equipped with

Ethernet interface)

USB

Host

Device

SD card

GT1455-QTBD(E)

Specifications

GT1450-QMBD(E)

RS-422/485 1ch

Transmission speed : 115,200/57,600/38,400/19,200/9,600/4,800bps

Connector shape

Application

: D-sub 9-pin (Female)

: PLC communication

Terminating resistor : Open/110 /330 (Switched by terminating resistor selector switch) *6

(At factory shipment: 330 )

GT1450-QLBD(E)

RS-232 1ch

Transmission speed : 115,200/57,600/38,400/19,200/9,600/4,800bps

Connector shape

Application

: D-sub 9-pin (Male)

: PLC communication, bar code reader, RFID connection, PC communication

(Project data upload/download, OS installation, transparent function)

Data transfer method: 100BASE-TX/10BASE-T, 1ch

Connector shape : RJ-45 (Modular jack)

Application : PLC communication, Gateway functions, PC communication

(Project data upload/download, OS installation, FA transparent function)

USB (Full Speed 12Mbps), 1ch

Connector shape

Application

: TYPE-A

: Data transfer, data storage

USB (Full Speed 12Mbps), 1ch

Connector shape

Application

: Mini-B

: PC communication (Project data upload/download, OS installation, FA transparent function)

In conformance to SD standard, 1ch

Applicable memory cards : SDHC memory card, SD memory card

Application : Project data upload/download, OS installation, logging data storage

Single tone (tone length adjustable)

Equivalent to IP67 (front section)

W164(6.46)  H135(5.32)  D55(2.17)[mm](inch)(Excluding USB environmental protective cover) (Horizontal format)

W153 (6.03)  H121(4.77)[mm] (inch) (Horizontal format)

Approx.

0.7kg (Excluding mounting fixtures)

GT Designer3 Version1.37P or later GT Designer3 Version1.118Y or later GT Designer3 Version1.37P or later

Buzzer output

Environmental protective structure

*7

External dimensions

Panel cutting dimensions

Weight

Compatible software package

*1 • Bright dots (always lit) and dark dots (unlit) may appear on a liquid crystal display panel. It is impossible to completely avoid this symptom, as the liquid crystal display comprises of a great number of display elements.

Flickers may be observed depending on the display color.

Please note that these dots appear due to its characteristic and are not caused by product defect.

• Flickers and partial discoloration may be generated on the liquid crystal display panel due to the display contents or the contrast adjustment.

However, please note that these phenomena appear due to its characteristic and are not caused by product defect.

• There is a difference in the display brightness and the color tones between liquid crystal display panels. When using multiple liquid crystal display panels, please note that there is an individual difference between them.

• A crosstalk (shadow as an extension of the display) may appear on the liquid crystal display panel. Please note that it appears due to its characteristic.

• When the display section is seen from the outside of the display angle, the display color seems like it has changed. Please note that it is due to its characteristic.

Please note that the response time, brightness and color of the liquid crystal display panel may vary depending on the usage environmental temperature.

Especially in the low temperature environment, the display response becomes slow due to the characteristics of the STN liquid crystal.

Please check the display response in advance for using this product.

• When the same screen is displayed for a long time, an incidental color or partial discoloration is generated on the screen due to heat damage, and it may not disappear.

To prevent heat damage, the screen saver function is effective.

For details on the screen saver function, refer to the following.

GT14 User's Manual

• Just after the GOT is powered off, sometimes an image lag or partial discoloration is generated temporary. However they are caused by the characteristic of the liquid crystal. (After powering off, they disappear within a few minutes.)

*2 Gradation inversion is a characteristic of liquid crystal displays.

Please be forewarned that depending on the displayed color, the visualization may be difficult even within the described view angle.

*3 Using the GOT Backlight OFF function can prolong the life of the backlight.

For details on the Backlight OFF function, refer to the following.

GT14 User's Manual

*4 The touch panel is analog resistive film-type. If you touch the panel simultaneously in 2 points or more, the switch that is located around the center of the touched point, if any, may operate. Do not touch the panel in 2 points or more simultaneously. Do not press the GOT display section with a pointed material as a pen or driver. Doing so can result in a damage or failure of the display section. For the analog-resistive film type touch panels, normally the adjustment is not required. However, the difference between a touched position and the object position may occur as the period of use elapses. When any difference between a touched position and the object position occurs, execute the touch panel calibration. When any difference between a touched position and the object position occurs, other object may be activated.

This may cause an unexpected operation due to incorrect output or malfunction.

*5 ROM in which new data can be written without deleting the written data.

*6 Set the terminating resistor selector switch of the GOT in accordance with the connection type when adopting GOT multidrop connection.

For details of GOT multidrop connection, refer to the following.

GOT1000 Series Connection Manual

*7 Compliant with IP67 when the USB environmental protection cover is attached. Not compliant when a USB cable is connected. Note that this does not guarantee all users' operation environment. The protection is not applied when the interface environment protection cover is removed.

In addition, the product may not be used in environments under exposition of oil or chemicals for a long period of time, or in environments filled with oil-mist.

Appearance

White stripe patterns may appear on the surface of the resin molded part of the product. Please note that these phenomena appear due to the characteristics of the material used in the product and are not caused by product defect.

3.3 Power Supply Specifications

Item

Input power supply voltage

Fuse (built-in, not exchangeable) 1.6A

GT1455-QTBD, GT1450-QMBD, GT1450-QLBD

24VDC (+10% -15%), ripple voltage 200mV or less

Specifications

GT1455-QTBDE, GT1450-QMBDE, GT1450-QLBDE

Item

Power consumption

At backlight off

Inrush current

Permissible instantaneous power failure time *1

Noise immunity

Dielectric withstand voltage

Insulation resistance

Applicable wire size

Applicable solderless terminal

Applicable tightening torque

(Terminal block terminal screw)

GT1455-QTBD, GT1450-QMBD, GT1450-QLBD

7.68W (320mA/24VDC) or less

6.72W (280mA/24VDC) or less

30A or less (26.4V) 2ms

Within 5ms

Noise voltage: 1000Vp-p, Noise width: 1 s (by noise simulator of 30 to 100Hz noise frequency)

500VAC for 1 minute (across power supply terminals and earth)

10M  or larger by insulation resistance tester (across power supply terminals and earth)

For power supply: 0.75[mm 2 ] or more, For grounding: 2[mm 2 ] or more

Solderless terminal for M3 screw RAV1.25-3, V2-N3A, FV2-N3A

0.5 to 0.8[N

 m]

Specifications

GT1455-QTBDE, GT1450-QMBDE, GT1450-QLBDE

8.40W (350mA/24VDC) or less

7.44W (310mA/24VDC) or less

*1 The GOT continues to operate even upon 5ms or shorter instantaneous power failure.

The GOT stops operating if there is extended power failure or voltage drop, while it automatically resumes operation as soon as the power is restored.

3.4 External Dimensions

164 (6.46")

22

(0.87") 120 (4.73")

23 (0.91")

22

(0.87")

120 (4.73")

152 (5.99")

4. Installation

4.1 Control Panel Inside Dimensions for Mounting GOT

Mount the GOT onto the control panel while considering the following control panel inside dimensions.

30 (1.19") 152 (5.99")

1)

Unit: mm (inch)

No

1)

Name

PLC connection cable/PC connection cable

Applicable cable

Some cables may need to be longer than the specified dimensions when connecting to the GOT. Therefore, consider the connector dimensions and bending radius of the cable as well for installation.

#4-40UNC

(inch screw type)

M2.6

(Metric screw type)

Panel thickness: 2 to 4mm

(0.07" to 0.15") or less

Unit: mm (inch)

4.2 Panel Cutting Dimensions

Make holes in the panel according to the dimensions list below.

Also, ensure 10mm spaces in upper and lower parts of the panel for mounting fixtures.

153

-

+ 2

0

( 6.03" )

10 (0.4") or more

0.08" 0

+ -

Panel thickness: 2 to 4mm

(0.07" to 0.15" inch)

10 (0.4") or more

Unit: mm (inch)

4.3 Mounting Position

When mounting the GOT, the clearances shown on the right must be left from a structure or the other device.

Installation

Environment

In the presence of radiated-noise or heat-generating equipment nearby

In the absence of radiated-noise or heat-generating equipment nearby

A,D

50 mm

(1.97”) or more

20 mm

(0.79”) or more

B

80 mm

(3.14”) or more

20 mm

(0.79”) or more

*1 Vertical format....50 mm (1.97”) or more

*2 Vertical format....80 mm (3.14”) or more

*1

C

50 mm

(1.97”) or more *2

20 mm

(0.79”) or more

E

100 mm

(3.93”) or more

20 mm

(0.79”) or more

C

Panel thickness: 2 to 4mm

(0.07" to 0.15" inch)

4.4 Control Panel Inside Temperature and Mounting Angle

When mounting the main unit to a control panel or similar, set the display section as shown below.

When the temperature inside the control panel is 40 to 55 C (Horizontal mount),

40 to 50 C (Vertical mount), the mounting angle should be in the range 60 to

105  degrees.

 The GOT will be deteriorated earlier if it is used at the mounting angle other than the above.

Therefore, the temperature inside the control panel should be within 40 C.

GOT display section

GOT back panel

60 °

105 °

Control panel, etc.

4.5 Installation Procedure

The GOT is designed to be embedded into a panel. Mount the GOT by following the procedure below. For panel cutting dimensions, refer to Section 4.2. Note that the panel thickness should be within 2 to 4mm.

1) Installing the packing

Packing

Install packing to the packing installation groove on the back panel of the GOT.

W h i l e r e f e r r i n g t o t h e c r o s s sectional view of the packing shown right, push the thinner side into the packing groove.

(Right drawing is the example of lateral format.)

Magnified illustration

Packing

Packing installation groove

Packing cross sectional view

Inserting direction

2) Inserting into the panel face

Insert the GOT from the front side of the panel.

3) Fixing the GOT

Engage the hook of the mounting fitting (accessory) to the unit fixing hole of the GOT and tighten the screw until the GOT is fixed with the mounting bolt (accessory).

The GOT will be fixed in 4 upper/ lower parts.

Tighten the mounting screw with the specified torque.

(Failure to do so may distort the p a n e l a n d m a k e a s u r f a c e waviness on the protective sheet.)

4) A protection film is attached on the display section of GOT prior to shipment. Remove the film when the installation is completed.

D

E

Mounting hole

Magnified illustration

Mounting fitting

Mounting screw

5. Wiring

5.1 Power Supply Wiring

Connect the power supply to the power terminals on the back panel of the GOT.

Use 0.75mm

2 or thicker cables to avoid voltage drop and tighten the terminal screw with the specified torque securely.

PC and external device connection cables

Power supply terminal

Grounding

(100W or less)

+

-

24VDC power supply

 Carry out the independent grounding if possible.

 If the independent grounding is impossible, carry out the shared grounding as shown in fig.2) below.

 Use the cable of 2mm 2 or more for grounding.

Set the grounding point closer to the GOT to make the grounding cable short as possible.

GOT

Other device

Grounding

(100W or less)

GOT

Grounding

(100W or less)

Other device

(1) Independent ground

...... Best condition

(2) Shared grounding

...... Good condition

1) Recommended terminal shape

3.2

Terminal screw

Solderless terminal

6.2mm or less

3.2

6.2mm or less

GOT

(3) Common grounding

...... Not allowed

Terminal screw

Other device

Solderless terminal

When wiring one cable to one terminal

When wiring two cables to one terminal

Applicable solderless terminal RAV 1.25-3, V2-N3A and FV2-N3A

6. Maintenance and Inspection

The GOT does not include consumable components that will cause the shorten life.

However, note that battery life is 5 years and LCD life is 50,000 hours. The life of backlight is 70,000 hours.

It is recommended to replace the battery periodically. (For the replacement of the liquid crystal screen and backlight, please consult your nearest sales office or FA Center.)

6.1 Daily Inspection

Daily inspection items

No.

1

2

Inspection Item

GOT mounting status

Inspection

Method

Check for loose mounting screws.

Loose terminal screws

Retighten screws with screwdriver

Proximate solderless terminals Visual check

Criterion

Securely mounted

Not loose

Proper intervals

Action

Retighten screws within the specified torque range

Retighten terminal screws

Correct

Loose connectors

Dirt on protection sheet

Visual check

Visual check

Not loose

Not outstanding

Retighten connector fixing screws

Replace with new one

3

Foreign material attachment

Visual check

No foreign matter sticking Remove clean

Refer to the following for the model names of the protection sheet or the replacement procedure.

GT14 User’s Manual

6.2 Periodic Inspection

Yearly or half-yearly inspection items

The following inspection should also be performed when equipment has been moved or modified or the wiring changed.

No.

Inspection Item

Inspection

Method

1

Ambient temperature

Surrounding environment Ambient humidity

Atmosphere

Make measurement with thermometer or hygrometer

Measure corrosive gas

Criterion Action

Display section

Other portions

No corrosive gas

0 to

50 C For use in control

0 to

55 C panel, temperature

10 to 90%RH inside control panel is ambient temperature

No.

2

Inspection Item

Power supply voltage check

Inspection

Method

24VDC

Measure voltage across terminals.

Criterion

20.4 to

26.4VDC

Action

Change supply power

3

4

Mounting status

Connection status

Looseness

Dirt, foreign matter

Loose terminal screws

Proximate solderless terminals

Move module

Visual check

Retighten screws with screwdriver

Visual check

Should be mounted firmly Retighten screws

No dirt, foreign matter sticking Remove, clean

Not loose

Proper intervals

Retighten terminal screws

Correct

5 Battery

Loose connectors

Visual check Not loose

Check the voltage status of the GOT built-in battery of [Time

Setting & display] in the

Utility.

No alarm displayed

Retighten connector fixing screws

Replace with new battery when the current battery has reached the specified life span, even if battery voltage is not displayed.

6.3 Battery Replacement

The battery is used for backing up the clock data, alarm history, recipe data, time action setting value, advanced alarm, advanced recipe, logging, hardcopy or SRAM user area. Screen data is stored in the flash memory and data is retained even if the battery is dead.

 Battery model name

GT14 is shipped with the following battery.

Product name

Battery

 Battery replacement procedure

1) Turn the GOT power off.

2) Open the battery cover of the GOT.

3) Remove the old battery from the GOT.

4) Disconnect the old battery connector and insert the new battery connector within 30s.

5) Insert the new battery into the GOT and close the battery cover.

6) Turn the GOT power on.

7) Check if the battery condition is normal with the utility.

Refer to the following for the details of battery status display.

GT14 User’s Manual

Model name

GT11-50BAT

Connector

Battery cover

Battery cover

 How to confirm production year and month

Connector

The production year and month of the battery built in the purchased GOT can be confirmed by the production No. (S/N) marked on the GOT main unit.

Example nameplate (manufacture's serial number 1160003)

* Actual product

nameplate differs from

the shown on the left.

7-digit

1 1 6 0 0 0 3

Control number

Month (example: Jun.), 1 to 9: Jan. to Sep.,

X: Oct., Y: Nov., Z: Dec.

Year (example: 2011) Last two digit of year

The production date of the optional replacement battery can be confirmed by the lot

No. marked on the nameplate (label) affixed on the battery.

Name plate

Model name

LOT.

GT11-50BAT

LOT.116

Connector

3-digit

1 1 6

Month

(example: Jun.)

1 (Jan.) to 9 (Sep.),

X (Oct.), Y (Nov.), Z (Dec.)

Year (example: 2011)

Last two digit of year

 Battery life

Approximate battery life:

5 years (ambient temperature: 25 C)

Battery replacement: In 4 to 5 years

Approximate life is 5 years, but life may be shorter depending on the ambient temperature, therefore, note that the battery must be replaced in 4 to 5 years. Make sure to purchase a new battery as needed as it self-discharges.

Battery status can be confirmed on a GOT utility screen.

For details of battery status or how to output alarm, refer to the following:

GT14 User’s Manual

7. Notification of CE marking

The following products have shown compliance through direct testing (to the identified standards) and design analysis (forming a technical construction file) to the European Directive for Electromagnetic Compatibility

(2004/108/EC) when used as directed by the appropriate documentation.

 This product is designed for use in industrial applications.

 Authorized Representative in the European Community: Mitsubishi Electric

Europe B.V. Gothaer Str. 8, 40880 Ratingen, Germany

- Type: Graphic Operation Terminal

- Models: GOT series

Standard

EN61131-2 : 2007

Programmable controllers

- Equipment, requirements and tests

EMI

EMS

Remark

Compliance with all relevant aspects of the standard.

(Radiated Emissions)

Compliance with all relevant aspects of the standard.

(ESD,RF electromagnetic field, EFTB, Surge, RF conducted disturbances and Power frequency magnetic field)

For more details please contact your local Mitsubishi Electric sales site.

For details of CE marking, refer to the following.

GT14 User's Manual

7.1 Notes regarding the use of GOT units

7.1.1

General notes on the use of communication cables

Any device which utilizes a data communication function is susceptible to the wider effects of local EMC noise. Therefore, when installing any communication cables care should always be taken with the routing and location of those cables.

Optional ferrite cores are recommended when the cable route is close to EMC noise sources like welders, large motors, etc. All tests have been performed with original Mitsubishi cables. For customer prepared cables, please refer to the manuals.

GOT Unit

All units

Ex.1

Existing Cables

Ex. GT01-C30R4-8P (as shown in EX.1)

A complete list of appropriate cables can be found in the GOT user's manual.

250mm

GT01-C30R4-8P

100mm

User Made Cables

3rd party cables need to be independently tested by the user to demonstrate EMC compliance.

Ex.2

Programmable controller

F F

140mm

Optional

Comes equipped

F

Optional

F = Ferrite core

Ex. Tokin-ESD-R-17S or similar

7.1.2

General notes on power supply

All units require an additional ferrite filter to be attached to the 24V DC power supply cables. The filter should be attached in a similar manner as shown in the figure opposite, i.e. the power cables are wrapped around the filter. However, as with all EMC situations the more correctly applied precautions the better the system's electromagnetic compatibility. The ferrite recommended is a TDK

ZCAT3035-1330 or similar (shown in Ex.2). The ferrite should be placed as near to the 24V DC terminals of the all units as possible (which should be within 75mm of the GOT terminal).

Note: The customer must evaluate conformance of the final produced unit with the EMC directive.

8. Certification of UL, cUL standards

 Environmental rating

Front: Type 4X (indoor use only)

 Using GOT

GOT is for use on a flat surface of a Type 1 or Type 4X (indoor use only) enclosure

This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.

Warranty

Exclusion of loss in opportunity and secondary loss from warranty liability

Regardless of the gratis warranty term, Mitsubishi shall not be liable for compensation to:

(1) Damages caused by any cause found not to be the responsibility of

Mitsubishi.

(2) Loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi products.

(3) Special damages and secondary damages whether foreseeable or not, compensation for accidents, and compensation for damages to products other than Mitsubishi products.

(4) Replacement by the user, maintenance of on-site equipment, start-up test run and other tasks.

For safe use

This product has been manufactured as a general-purpose part for general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life.

Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with

Mitsubishi Electric.

This product has been manufactured under strict quality control. However when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system.

HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

Built-in interface

RS-232

Item

RS-422/485

Ethernet

(Only in models equipped with

Ethernet interface)

USB

Host

Device

SD card

GT1455-QTBD(E)

Specifications

GT1450-QMBD(E)

RS-422/485 1ch

Transmission speed : 115,200/57,600/38,400/19,200/9,600/4,800bps

Connector shape

Application

: D-sub 9-pin (Female)

: PLC communication

Terminating resistor : Open/110 /330 (Switched by terminating resistor selector switch) *6

(At factory shipment: 330 )

GT1450-QLBD(E)

RS-232 1ch

Transmission speed : 115,200/57,600/38,400/19,200/9,600/4,800bps

Connector shape

Application

: D-sub 9-pin (Male)

: PLC communication, bar code reader, RFID connection, PC communication

(Project data upload/download, OS installation, transparent function)

Data transfer method: 100BASE-TX/10BASE-T, 1ch

Connector shape : RJ-45 (Modular jack)

Application : PLC communication, Gateway functions, PC communication

(Project data upload/download, OS installation, FA transparent function)

USB (Full Speed 12Mbps), 1ch

Connector shape

Application

: TYPE-A

: Data transfer, data storage

USB (Full Speed 12Mbps), 1ch

Connector shape

Application

: Mini-B

: PC communication (Project data upload/download, OS installation, FA transparent function)

In conformance to SD standard, 1ch

Applicable memory cards : SDHC memory card, SD memory card

Application : Project data upload/download, OS installation, logging data storage

Single tone (tone length adjustable)

Equivalent to IP67 (front section)

W164(6.46)  H135(5.32)  D55(2.17)[mm](inch)(Excluding USB environmental protective cover) (Horizontal format)

W153 (6.03)  H121(4.77)[mm] (inch) (Horizontal format)

Approx.

0.7kg (Excluding mounting fixtures)

GT Designer3 Version1.37P or later GT Designer3 Version1.118Y or later GT Designer3 Version1.37P or later

Buzzer output

Environmental protective structure

*7

External dimensions

Panel cutting dimensions

Weight

Compatible software package

*1 • Bright dots (always lit) and dark dots (unlit) may appear on a liquid crystal display panel. It is impossible to completely avoid this symptom, as the liquid crystal display comprises of a great number of display elements.

Flickers may be observed depending on the display color.

Please note that these dots appear due to its characteristic and are not caused by product defect.

• Flickers and partial discoloration may be generated on the liquid crystal display panel due to the display contents or the contrast adjustment.

However, please note that these phenomena appear due to its characteristic and are not caused by product defect.

• There is a difference in the display brightness and the color tones between liquid crystal display panels. When using multiple liquid crystal display panels, please note that there is an individual difference between them.

• A crosstalk (shadow as an extension of the display) may appear on the liquid crystal display panel. Please note that it appears due to its characteristic.

• When the display section is seen from the outside of the display angle, the display color seems like it has changed. Please note that it is due to its characteristic.

Please note that the response time, brightness and color of the liquid crystal display panel may vary depending on the usage environmental temperature.

Especially in the low temperature environment, the display response becomes slow due to the characteristics of the STN liquid crystal.

Please check the display response in advance for using this product.

• When the same screen is displayed for a long time, an incidental color or partial discoloration is generated on the screen due to heat damage, and it may not disappear.

To prevent heat damage, the screen saver function is effective.

For details on the screen saver function, refer to the following.

GT14 User's Manual

• Just after the GOT is powered off, sometimes an image lag or partial discoloration is generated temporary. However they are caused by the characteristic of the liquid crystal. (After powering off, they disappear within a few minutes.)

*2 Gradation inversion is a characteristic of liquid crystal displays.

Please be forewarned that depending on the displayed color, the visualization may be difficult even within the described view angle.

*3 Using the GOT Backlight OFF function can prolong the life of the backlight.

For details on the Backlight OFF function, refer to the following.

GT14 User's Manual

*4 The touch panel is analog resistive film-type. If you touch the panel simultaneously in 2 points or more, the switch that is located around the center of the touched point, if any, may operate. Do not touch the panel in 2 points or more simultaneously. Do not press the GOT display section with a pointed material as a pen or driver. Doing so can result in a damage or failure of the display section. For the analog-resistive film type touch panels, normally the adjustment is not required. However, the difference between a touched position and the object position may occur as the period of use elapses. When any difference between a touched position and the object position occurs, execute the touch panel calibration. When any difference between a touched position and the object position occurs, other object may be activated.

This may cause an unexpected operation due to incorrect output or malfunction.

*5 ROM in which new data can be written without deleting the written data.

*6 Set the terminating resistor selector switch of the GOT in accordance with the connection type when adopting GOT multidrop connection.

For details of GOT multidrop connection, refer to the following.

GOT1000 Series Connection Manual

*7 Compliant with IP67 when the USB environmental protection cover is attached. Not compliant when a USB cable is connected. Note that this does not guarantee all users' operation environment. The protection is not applied when the interface environment protection cover is removed.

In addition, the product may not be used in environments under exposition of oil or chemicals for a long period of time, or in environments filled with oil-mist.

Appearance

White stripe patterns may appear on the surface of the resin molded part of the product. Please note that these phenomena appear due to the characteristics of the material used in the product and are not caused by product defect.

3.3 Power Supply Specifications

Item

Input power supply voltage

Fuse (built-in, not exchangeable) 1.6A

GT1455-QTBD, GT1450-QMBD, GT1450-QLBD

24VDC (+10% -15%), ripple voltage 200mV or less

Specifications

GT1455-QTBDE, GT1450-QMBDE, GT1450-QLBDE

Item

Power consumption

At backlight off

Inrush current

Permissible instantaneous power failure time *1

Noise immunity

Dielectric withstand voltage

Insulation resistance

Applicable wire size

Applicable solderless terminal

Applicable tightening torque

(Terminal block terminal screw)

GT1455-QTBD, GT1450-QMBD, GT1450-QLBD

7.68W (320mA/24VDC) or less

6.72W (280mA/24VDC) or less

30A or less (26.4V) 2ms

Within 5ms

Noise voltage: 1000Vp-p, Noise width: 1 s (by noise simulator of 30 to 100Hz noise frequency)

500VAC for 1 minute (across power supply terminals and earth)

10M  or larger by insulation resistance tester (across power supply terminals and earth)

For power supply: 0.75[mm 2 ] or more, For grounding: 2[mm 2 ] or more

Solderless terminal for M3 screw RAV1.25-3, V2-N3A, FV2-N3A

0.5 to 0.8[N

 m]

Specifications

GT1455-QTBDE, GT1450-QMBDE, GT1450-QLBDE

8.40W (350mA/24VDC) or less

7.44W (310mA/24VDC) or less

*1 The GOT continues to operate even upon 5ms or shorter instantaneous power failure.

The GOT stops operating if there is extended power failure or voltage drop, while it automatically resumes operation as soon as the power is restored.

3.4 External Dimensions

164 (6.46")

22

(0.87") 120 (4.73")

23 (0.91")

22

(0.87")

120 (4.73")

152 (5.99")

4. Installation

4.1 Control Panel Inside Dimensions for Mounting GOT

Mount the GOT onto the control panel while considering the following control panel inside dimensions.

30 (1.19") 152 (5.99")

1)

Unit: mm (inch)

No

1)

Name

PLC connection cable/PC connection cable

Applicable cable

Some cables may need to be longer than the specified dimensions when connecting to the GOT. Therefore, consider the connector dimensions and bending radius of the cable as well for installation.

#4-40UNC

(inch screw type)

M2.6

(Metric screw type)

Panel thickness: 2 to 4mm

(0.07" to 0.15") or less

Unit: mm (inch)

4.2 Panel Cutting Dimensions

Make holes in the panel according to the dimensions list below.

Also, ensure 10mm spaces in upper and lower parts of the panel for mounting fixtures.

153

-

+ 2

0

( 6.03" )

10 (0.4") or more

0.08" 0

+ -

Panel thickness: 2 to 4mm

(0.07" to 0.15" inch)

10 (0.4") or more

Unit: mm (inch)

4.3 Mounting Position

When mounting the GOT, the clearances shown on the right must be left from a structure or the other device.

Installation

Environment

In the presence of radiated-noise or heat-generating equipment nearby

In the absence of radiated-noise or heat-generating equipment nearby

A,D

50 mm

(1.97”) or more

20 mm

(0.79”) or more

B

80 mm

(3.14”) or more

20 mm

(0.79”) or more

*1 Vertical format....50 mm (1.97”) or more

*2 Vertical format....80 mm (3.14”) or more

*1

C

50 mm

(1.97”) or more *2

20 mm

(0.79”) or more

E

100 mm

(3.93”) or more

20 mm

(0.79”) or more

C

Panel thickness: 2 to 4mm

(0.07" to 0.15" inch)

4.4 Control Panel Inside Temperature and Mounting Angle

When mounting the main unit to a control panel or similar, set the display section as shown below.

When the temperature inside the control panel is 40 to 55 C (Horizontal mount),

40 to 50 C (Vertical mount), the mounting angle should be in the range 60 to

105  degrees.

 The GOT will be deteriorated earlier if it is used at the mounting angle other than the above.

Therefore, the temperature inside the control panel should be within 40 C.

GOT display section

GOT back panel

60 °

105 °

Control panel, etc.

4.5 Installation Procedure

The GOT is designed to be embedded into a panel. Mount the GOT by following the procedure below. For panel cutting dimensions, refer to Section 4.2. Note that the panel thickness should be within 2 to 4mm.

1) Installing the packing

Packing

Install packing to the packing installation groove on the back panel of the GOT.

W h i l e r e f e r r i n g t o t h e c r o s s sectional view of the packing shown right, push the thinner side into the packing groove.

(Right drawing is the example of lateral format.)

Magnified illustration

Packing

Packing installation groove

Packing cross sectional view

Inserting direction

2) Inserting into the panel face

Insert the GOT from the front side of the panel.

3) Fixing the GOT

Engage the hook of the mounting fitting (accessory) to the unit fixing hole of the GOT and tighten the screw until the GOT is fixed with the mounting bolt (accessory).

The GOT will be fixed in 4 upper/ lower parts.

Tighten the mounting screw with the specified torque.

(Failure to do so may distort the p a n e l a n d m a k e a s u r f a c e waviness on the protective sheet.)

4) A protection film is attached on the display section of GOT prior to shipment. Remove the film when the installation is completed.

D

E

Mounting hole

Magnified illustration

Mounting fitting

Mounting screw

5. Wiring

5.1 Power Supply Wiring

Connect the power supply to the power terminals on the back panel of the GOT.

Use 0.75mm

2 or thicker cables to avoid voltage drop and tighten the terminal screw with the specified torque securely.

PC and external device connection cables

Power supply terminal

Grounding

(100W or less)

+

-

24VDC power supply

 Carry out the independent grounding if possible.

 If the independent grounding is impossible, carry out the shared grounding as shown in fig.2) below.

 Use the cable of 2mm 2 or more for grounding.

Set the grounding point closer to the GOT to make the grounding cable short as possible.

GOT

Other device

Grounding

(100W or less)

GOT

Grounding

(100W or less)

Other device

(1) Independent ground

...... Best condition

(2) Shared grounding

...... Good condition

1) Recommended terminal shape

3.2

Terminal screw

Solderless terminal

6.2mm or less

3.2

6.2mm or less

GOT

(3) Common grounding

...... Not allowed

Terminal screw

Other device

Solderless terminal

When wiring one cable to one terminal

When wiring two cables to one terminal

Applicable solderless terminal RAV 1.25-3, V2-N3A and FV2-N3A

6. Maintenance and Inspection

The GOT does not include consumable components that will cause the shorten life.

However, note that battery life is 5 years and LCD life is 50,000 hours. The life of backlight is 70,000 hours.

It is recommended to replace the battery periodically. (For the replacement of the liquid crystal screen and backlight, please consult your nearest sales office or FA Center.)

6.1 Daily Inspection

Daily inspection items

No.

1

2

Inspection Item

GOT mounting status

Inspection

Method

Check for loose mounting screws.

Loose terminal screws

Retighten screws with screwdriver

Proximate solderless terminals Visual check

Criterion

Securely mounted

Not loose

Proper intervals

Action

Retighten screws within the specified torque range

Retighten terminal screws

Correct

Loose connectors

Dirt on protection sheet

Visual check

Visual check

Not loose

Not outstanding

Retighten connector fixing screws

Replace with new one

3

Foreign material attachment

Visual check

No foreign matter sticking Remove clean

Refer to the following for the model names of the protection sheet or the replacement procedure.

GT14 User’s Manual

6.2 Periodic Inspection

Yearly or half-yearly inspection items

The following inspection should also be performed when equipment has been moved or modified or the wiring changed.

No.

Inspection Item

Inspection

Method

1

Ambient temperature

Surrounding environment Ambient humidity

Atmosphere

Make measurement with thermometer or hygrometer

Measure corrosive gas

Criterion Action

Display section

Other portions

No corrosive gas

0 to

50 C For use in control

0 to

55 C panel, temperature

10 to 90%RH inside control panel is ambient temperature

No.

2

Inspection Item

Power supply voltage check

Inspection

Method

24VDC

Measure voltage across terminals.

Criterion

20.4 to

26.4VDC

Action

Change supply power

3

4

Mounting status

Connection status

Looseness

Dirt, foreign matter

Loose terminal screws

Proximate solderless terminals

Move module

Visual check

Retighten screws with screwdriver

Visual check

Should be mounted firmly Retighten screws

No dirt, foreign matter sticking Remove, clean

Not loose

Proper intervals

Retighten terminal screws

Correct

5 Battery

Loose connectors

Visual check Not loose

Check the voltage status of the GOT built-in battery of [Time

Setting & display] in the

Utility.

No alarm displayed

Retighten connector fixing screws

Replace with new battery when the current battery has reached the specified life span, even if battery voltage is not displayed.

6.3 Battery Replacement

The battery is used for backing up the clock data, alarm history, recipe data, time action setting value, advanced alarm, advanced recipe, logging, hardcopy or SRAM user area. Screen data is stored in the flash memory and data is retained even if the battery is dead.

 Battery model name

GT14 is shipped with the following battery.

Product name

Battery

 Battery replacement procedure

1) Turn the GOT power off.

2) Open the battery cover of the GOT.

3) Remove the old battery from the GOT.

4) Disconnect the old battery connector and insert the new battery connector within 30s.

5) Insert the new battery into the GOT and close the battery cover.

6) Turn the GOT power on.

7) Check if the battery condition is normal with the utility.

Refer to the following for the details of battery status display.

GT14 User’s Manual

Model name

GT11-50BAT

Connector

Battery cover

Battery cover

 How to confirm production year and month

Connector

The production year and month of the battery built in the purchased GOT can be confirmed by the production No. (S/N) marked on the GOT main unit.

Example nameplate (manufacture's serial number 1160003)

* Actual product

nameplate differs from

the shown on the left.

7-digit

1 1 6 0 0 0 3

Control number

Month (example: Jun.), 1 to 9: Jan. to Sep.,

X: Oct., Y: Nov., Z: Dec.

Year (example: 2011) Last two digit of year

The production date of the optional replacement battery can be confirmed by the lot

No. marked on the nameplate (label) affixed on the battery.

Name plate

Model name

LOT.

GT11-50BAT

LOT.116

Connector

3-digit

1 1 6

Month

(example: Jun.)

1 (Jan.) to 9 (Sep.),

X (Oct.), Y (Nov.), Z (Dec.)

Year (example: 2011)

Last two digit of year

 Battery life

Approximate battery life:

5 years (ambient temperature: 25 C)

Battery replacement: In 4 to 5 years

Approximate life is 5 years, but life may be shorter depending on the ambient temperature, therefore, note that the battery must be replaced in 4 to 5 years. Make sure to purchase a new battery as needed as it self-discharges.

Battery status can be confirmed on a GOT utility screen.

For details of battery status or how to output alarm, refer to the following:

GT14 User’s Manual

7. Notification of CE marking

The following products have shown compliance through direct testing (to the identified standards) and design analysis (forming a technical construction file) to the European Directive for Electromagnetic Compatibility

(2004/108/EC) when used as directed by the appropriate documentation.

 This product is designed for use in industrial applications.

 Authorized Representative in the European Community: Mitsubishi Electric

Europe B.V. Gothaer Str. 8, 40880 Ratingen, Germany

- Type: Graphic Operation Terminal

- Models: GOT series

Standard

EN61131-2 : 2007

Programmable controllers

- Equipment, requirements and tests

EMI

EMS

Remark

Compliance with all relevant aspects of the standard.

(Radiated Emissions)

Compliance with all relevant aspects of the standard.

(ESD,RF electromagnetic field, EFTB, Surge, RF conducted disturbances and Power frequency magnetic field)

For more details please contact your local Mitsubishi Electric sales site.

For details of CE marking, refer to the following.

GT14 User's Manual

7.1 Notes regarding the use of GOT units

7.1.1

General notes on the use of communication cables

Any device which utilizes a data communication function is susceptible to the wider effects of local EMC noise. Therefore, when installing any communication cables care should always be taken with the routing and location of those cables.

Optional ferrite cores are recommended when the cable route is close to EMC noise sources like welders, large motors, etc. All tests have been performed with original Mitsubishi cables. For customer prepared cables, please refer to the manuals.

GOT Unit

All units

Ex.1

Existing Cables

Ex. GT01-C30R4-8P (as shown in EX.1)

A complete list of appropriate cables can be found in the GOT user's manual.

250mm

GT01-C30R4-8P

100mm

User Made Cables

3rd party cables need to be independently tested by the user to demonstrate EMC compliance.

Ex.2

Programmable controller

F F

140mm

Optional

Comes equipped

F

Optional

F = Ferrite core

Ex. Tokin-ESD-R-17S or similar

7.1.2

General notes on power supply

All units require an additional ferrite filter to be attached to the 24V DC power supply cables. The filter should be attached in a similar manner as shown in the figure opposite, i.e. the power cables are wrapped around the filter. However, as with all EMC situations the more correctly applied precautions the better the system's electromagnetic compatibility. The ferrite recommended is a TDK

ZCAT3035-1330 or similar (shown in Ex.2). The ferrite should be placed as near to the 24V DC terminals of the all units as possible (which should be within 75mm of the GOT terminal).

Note: The customer must evaluate conformance of the final produced unit with the EMC directive.

8. Certification of UL, cUL standards

 Environmental rating

Front: Type 4X (indoor use only)

 Using GOT

GOT is for use on a flat surface of a Type 1 or Type 4X (indoor use only) enclosure

This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.

Warranty

Exclusion of loss in opportunity and secondary loss from warranty liability

Regardless of the gratis warranty term, Mitsubishi shall not be liable for compensation to:

(1) Damages caused by any cause found not to be the responsibility of

Mitsubishi.

(2) Loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi products.

(3) Special damages and secondary damages whether foreseeable or not, compensation for accidents, and compensation for damages to products other than Mitsubishi products.

(4) Replacement by the user, maintenance of on-site equipment, start-up test run and other tasks.

For safe use

This product has been manufactured as a general-purpose part for general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life.

Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with

Mitsubishi Electric.

This product has been manufactured under strict quality control. However when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system.

HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

JY997D43901F

GT1455-QTBD(E), GT1450-QMBD(E)

GT1450-QLBD(E)

GT14 General Description

Manual Number

Date

JY997D43901F

December 2015

This manual describes the part names, dimensions, mounting, and specifications of the product. Before use, read this manual and manuals of relevant products fully to acquire proficiency in handling and operating the product. Make sure to learn all the product information, safety information, and precautions.

And, store this manual in a safe place so that you can take it out and read it whenever necessary. Always forward it to the end user.

Registration

Ethernet is a trademark of Xerox Corporation in the United States. The company name and the product name to be described in this manual are the registered trademarks or trademarks of each company.

Effective December 2015

Specifications are subject to change without notice.

 2011 MITSUBISHI ELECTRIC CORPORATION

Safety Precaution

(Read these precautions before using.)

Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly.

The precautions given in this manual are concerned with this product.

In this manual, the safety precautions are ranked as "WARNING" and

"CAUTION".

Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.

Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage.

Depending on circumstances, procedures indicated by "CAUTION" may also be linked to serious results.

In any case, it is important to follow the directions for usage.

DESIGN PRECAUTIONS

 Some failures of the GOT or cable may keep the outputs on or off.

An external monitoring circuit should be provided to check for output signals which may lead to a serious accident.

Not doing so can cause an accident due to false output or malfunction.

 If a communication fault (including cable disconnection) occurs during monitoring on the GOT, communication between the GOT and PLC CPU is suspended and the GOT becomes inoperative.

A system where the GOT is used should be configured to perform any significant operation to the system by using the switches of a device other than the GOT on the assumption that a GOT communication fault will occur.

Not doing so can cause an accident due to false output or malfunction.

 Do not use the GOT as the warning device that may cause a serious accident. An independent and redundant hardware or mechanical interlock is required to configure the device that displays and outputs serious warning.

Failure to observe this instruction may result in an accident due to incorrect output or malfunction.

 Incorrect operation of the touch switch(s) may lead to a serious accident if the

GOT backlight is gone out. When the GOT backlight goes out, the POWER

LED flickers (green/orange) and the display section turns black and causes the monitor screen to appear blank, while the input of the touch switch(s) remains active. This may confuse an operator in thinking that the GOT is in

"screensaver" mode, who then tries to release the GOT from this mode by touching the display section, which may cause a touch switch to operate.

Note that the following occurs on the GOT when the backlight goes out.

- The POWER LED flickers (green/orange) and the monitor screen appears blank

 The display section is an analog-resistive type touch panel.

If you touch the display section simultaneously in 2 points or more, the switch that is located around the center of the touched point, if any, may operate.

Do not touch the display section in 2 points or more simultaneously.

Doing so may cause an accident due to incorrect output or malfunction.

 When programs or parameters of the controller (such as a PLC) that is monitored by the GOT are changed, be sure to reset the GOT or shut off the power of the GOT at the same time.

Not doing so can cause an accident due to false output or malfunction.

DESIGN PRECAUTIONS

 Do not bundle the control and communication cables with main-circuit, power or other wiring.

Run the above cables separately from such wiring and keep them a minimum of

100mm (3.94in.) apart.Not doing so noise can cause a malfunction.

 Do not press the GOT display section with a pointed material as a pen or driver.

Doing so can result in a damage or failure of the display section.

 When using the GOT with Ethernet connection, available IP addresses are restricted depending on the system configuration.

- When connecting two or more GOT units to the Ethernet network:

Do not specify the IP address "192.168.0.18" to the GOT or any connected equipment.

- When connecting one GOT unit to the Ethernet network:

Do not specify the IP address "192.168.0.18" to any connected equipment other than the GOT.

If the IP address "192.168.0.18" is specified in the above system configuration,

IP address overlap occurs when the GOT is started up, and adverse effect may be given to communication in the equipment in which the IP address

"192.168.0.18" is set. Operation executed at IP address overlap varies depending on the equipment and system.

 Turn on the power of the connected equipment and network equipment, and make them ready for communication before connecting them to the GOT.

If the connected equipment and network equipment are not ready for communication, a communication error may occur in the GOT.

MOUNTING PRECAUTIONS

 Be sure to shut off all phases of the external power supply used by the system before mounting or removing the GOT to/from the panel.

Not doing so can cause the unit to fail or malfunction.

MOUNTING PRECAUTIONS

 Use the GOT in the environment that satisfies the general specifications described in this manual. Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration.

 When mounting the GOT to the control panel, tighten the mounting screws in the specified torque range. Undertightening can cause the GOT to drop, short circuit or malfunction, and deteriorate the waterproof effect and oilproof effect.

Overtightening can cause a drop, short circuit or malfunction due to the damage of the screws or the GOT, and deteriorate the waterproof effect and oilproof effect due to distortion of the protective cover for oil, GOT or panel.

 Never drop cutting chips and electric wire chips into the ventilation window of the

GOT when you drill screw holes or perform wiring.

Otherwise, fire, failure or malfunction may be caused.

 When inserting/removing a SD card into/from the GOT, turn the SD card access switch off in advance. Failure to do so may corrupt data within the SD card.

 When removing a SD card from the GOT, make sure to support the SD card by hand, as it may pop out. Failure to do so may cause the SD card to drop from the

GOT and break.

 When installing a USB memory to the GOT, make sure to install the USB memory to the USB interface firmly.

Failure to do so may cause a malfunction due to poor contact.

 Before removing the USB memory from the GOT, operate the utility screen for removal. After the successful completion dialog box is displayed, remove the memory by hand carefully. Failure to do so may cause the USB memory to drop, resulting in a damage or failure of the memory.

 Operate and store the GOT in environments without direct sunlight, high temperature, dust, humidity, and vibrations.

 When using the GOT in the environment of oil or chemicals, use the protective cover for oil.

Failure to do so may cause failure or malfunction due to the oil or chemical entering into the GOT.

WIRING PRECAUTIONS

 Be sure to shut off all phases of the external power supply used by the system before wiring. Failure to do so may result in an electric shock, product damage or malfunctions.

 Please make sure to ground FG terminal of the GOT power supply section by applying 100 or less which is used exclusively for the GOT. Not doing so may cause an electric shock or malfunction.

 Correctly wire the GOT power supply section after confirming the rated voltage and terminal arrangement of the product. Not doing so can cause a fire or failure.

 Tighten the terminal screws of the GOT power supply section in the specified torque range. Undertightening can cause a short circuit or malfunction.

Overtightening can cause a short circuit or malfunction due to the damage of the screws or the GOT.

 Exercise care to avoid foreign matter such as chips and wire offcuts entering the

GOT. Not doing so can cause a fire, failure or malfunction.

WIRING PRECAUTIONS

 The cables connected to the unit must be run in ducts or clamped.

Not doing so can cause the unit or cable to be damaged due to the dangling, motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault.

 When unplugging the cable connected to the unit, do not hold and pull the cable portion.

Doing so can cause the unit or cable to be damaged or can cause a malfunction due to a cable connection fault.

 Plug the communication cable into the connector of the connected unit and tighten the mounting and terminal screws in the specified torque range.

Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit.

TEST OPERATION

PRECAUTIONS

 Before performing the test operations of the user creation monitor screen (such as turning ON or OFF bit device, changing the word device current value, changing the settings or current values of the timer or counter, and changing the buffer memory current value), read through the manual carefully and make yourself familiar with the operation method.

During test operation, never change the data of the devices which are used to perform significant operation for the system. False output or malfunction can cause an accident.

STARTUP/MAINTENANCE

PRECAUTIONS

 When power is on, do not touch the terminals.

Doing so can cause an electric shock or malfunction.

 Connect the battery correctly. Do not discharge, disassemble, heat, short, solder or throw the battery into the fire. Incorrect handling may cause the battery to generate heat, burst or take fire, resulting in injuries or fires.

 Before starting cleaning or terminal screw retightening, always switch off the power externally in all phases. Not switching the power off in all phases can cause a unit failure or malfunction. Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit.

STARTUP/MAINTENANCE

PRECAUTIONS

 Do not disassemble or modify the unit.

Doing so can cause a failure, malfunction, injury or fire.

 Do not touch the conductive and electronic parts of the unit directly.

Doing so can cause a unit malfunction or failure.

 The cables connected to the unit must be run in ducts or clamped.

Not doing so can cause the unit or cable to be damaged due to the dangling, motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault.

 When unplugging the cable connected to the unit, do not hold and pull the cable portion. Doing so can cause the unit or cable to be damaged or can cause a malfunction due to a cable connection fault.

 Do not drop or apply any impact to the battery.If any impact has been applied, discard the battery and never use it.

The battery may be damaged by the drop or impact.

 Before touching the unit, always touch grounded metal, etc. to discharge static electricity from human body, etc.

Not doing so can cause the unit to fail or malfunction.

 Replace battery with GT11-50BAT by Mitsubishi electric Co. only.

Use of another battery may present a risk of fire or explosion.

 Dispose of used battery promptly.

Keep away from children. Do not disassemble and do not dispose of in fire.

DISPOSAL PRECAUTIONS

 When disposing of the product, handle it as industrial waste.

 When disposing of batteries, separate them from other wastes according to the local regulations.

(For details of the battery directive in EU member states, refer GOT User's

Manual.)

TOUCH PANEL

PRECAUTIONS

 For the analog-resistive film type touch panels, normally the adjustment is not required.

However, the difference between a touched position and the object position may occur as the period of use elapses.

When any difference between a touched position and the object position occurs, execute the touch panel calibration.

 When any difference between a touched position and the object position occurs, other object may be activated.

This may cause an unexpected operation due to incorrect output or malfunction.

TRANSPORTATION

PRECAUTIONS

 When transporting lithium batteries, make sure to treat them based on the transport regulations.

(Refer to User's Manual for details of the regurated models.)

 Before transporting the GOT, turn the GOT power on and check that the battery voltage status is normal on the Time setting & display screen (utilities screen). In addition, confirm that the adequate battery life remains on the rating plate.

Transporting the GOT with the low battery voltage or the battery the reached battery life may unstabilize the backup data unstable during transportation.

 Make sure to transport the GOT main unit and/or relevant unit(s) in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of this manual, as they are precision devices. Failure to do so may cause the unit to fail.

Check if the unit operates correctly after transportation.

Associated Manuals

The following manuals are relevant to this product. When these loose manuals are required, please consult with our local distributor.

Manual name Contents

Manual Number

(Model Code)

GT14 User’s Manual

(sold separately)

D e s c r i b e s t h e G T 1 4 h a r d w a r e relevant content such as part names, external dimensions, mounting, power supply wiring, specifications, and introduction to option devices

GT Designer3

Version1 Screen

Design Manual

(For GOT1000

S e r i e s )

(Fundamentals)

1/2, 2/2

(sold separately) *1

GT Designer3

Version1 Screen

Design Manual

(For GOT1000

Series) (Functions)

1/2, 2/2

(sold separately) *1

D e s c r i b e s m e t h o d s o f t h e G T

Designer3 installation operation, basic operation for drawing and transmitting data to GOT1000 series

Describes specifications and settings of the object functions used in GT

Designer3

JY997D44801

(09R823)

SH-080866ENG

(1D7MB9)

SH-080867ENG

(1D7MC1)

*1 Stored in the GT Works3/GT Designer3 in PDF format.

For details of a PLC to be connected, refer to the PLC user's manual respectively.

Bundled Items

Product

Name

Model Name

GOT

Specifications

GT1455-QTBDE

GT1455-QTBD

GT1450-QMBDE

GT1450-QMBD

GT1450-QLBDE

GT1450-QLBD

5.7" diagonal [320  240 dots], TFT color (65536 colors), built-in battery and Ethernet interface

5.7" diagonal [320  240 dots], TFT color (65536 colors), built-in battery

5.7" diagonal [320  240 dots], TFT monochrome

(black/white), built-in battery and Ethernet interface

5.7" diagonal [320  240 dots], TFT monochrome

(black/white), built-in battery

5.7" diagonal [320  240 dots], STN monochrome

(black/white), built-in battery and Ethernet interface

5.7" diagonal [320  240 dots], STN monochrome

(black/white), built-in battery

Bundled item

Mounting brackets

Mounting screws: M4 x 35mm (1.38")

Dust-/Water-proof packing

GT14 General Description (This manual)

1. Features

1) Improved monitoring performance and connectivity to FA devices

- Multiple languages are displayed using the Unicode2.1-compatible fonts and beautiful characters are drawn using the TrueType and high quality fonts.

- Two types of display modes are provided: 65536-colors display and monochrome display.

In the monochrome display, 16 scales are used to improve the display.

A fine and beautiful full-color display which shows even small characters clearly, is enabled by adopting the high intensity, wide viewing angle and high definition TFT color LCD. (Also compatible with digital screen displays with 65536 colors, BMP, etc.)

- High-speed monitoring through high-speed serial communication at 115.2 kbps maximum or through Ethernet connection.

- High speed display and high speed touch switch response.

2) More efficient GOT operations including screen design, startup, adjustment, management and maintenance works

- The 9MB built-in flash memory is included as standard.

- SD card interface is included as standard.

- RS-232 interface is included as standard.

- RS-422/485 interface is included as standard.

- USB interface (host/device) are included as standard.

- Ethernet interface is included. (in some models)

3) Enhanced support of FA setup tools

- PLC program transfer and monitoring are possible via the personal computer that is connected to the GOT if connected directly to the A, QnA,

L, Q, or FX series of the PLC CPU (FA transparent function).

2. Part Name

2.1 Front

4)

Quantity

4

4

1

1

2.2 Back/Bottom

1)

2)

17)

4)

11) 12) 3)

5) 7) 8)

6)

Battery cover opened

14)

9)

13)

16)

10) 15)

17)

1) 2)

3)

5) 6)

No

6)

Name

1) Display screen

2) Touch panel

3) POWER LED

4) Logo label

5) USB interface

Specifications

Displays the utility screen and the user creation screen.

GT1455-QTBD(E):320 240 dots, TFT color liquid crystal

GT1450-QMBD(E):320 240 dots, TFT monochrome

(white/black) liquid crystal, 16 scales

GT1450-QLBD(E):320 240 dots, STN monochrome

(white/black) liquid crystal, 16 scales

For operating the touch switches in the utility screen and the user creation screen

Lit in green: Power is correctly supplied

Lit in orange: Screen saving

Blinking in orange/green: Blown backlight bulb

Not lit: Power is not supplied

Removable

USB interface for connecting a personal computer

(Device)

O S i n s t a l l a t i o n , p r o j e c t d a t a d o w n l o a d , FA transparent

USB environmental protection cover

Opens/Closes when the USB interface is used.

For the PC connection, refer to the following.

GT14 User’s Manual

No.

1)

2)

3)

4)

5)

6)

7)

8)

9)

10)

11)

12)

13)

14)

Name

RS-232 interface

RS-422/485 interface

USB interface

Hole for preventing

USB cable disconnection

For communicating with controller or personal computer

(D-sub 9-pin male)

Specifications

For communicating with controller (D-sub 9-pin female)

For data transfer, data storage USB interface (Host)

Hole for fixing the USB cable with a cable tie (such as

Insulock) to prevent disconnection

Rating plate

(nameplate)

SD card interface

SD card access LED

--

Interface for installing the SD card to GOT

SD card access switch

Lit: SD card accessed

Not lit: SD card not accessed

Switch for prohibiting access to SD card before removing the SD card from the GOT

ON: SD card being accessed (SD card removal prohibited)

OFF: No access to SD card (SD card removal possible)

Battery

Battery cover

GT11-50BAT battery for storing clock data, alarm history and recipe data

Open or close when replacing the battery.

Opened and closed when the terminating resistor is changed over

Power terminal

Power terminal and FG terminal

(for power supply (24VDC) to GOT and grounding)

Power terminal cover

Open or close when connecting a power terminal.

(Color: transparent)

Hardware reset switch (Use an isolated rod to operate.) Reset switch

Terminating resistor selector switch

Terminating resistor selector switch of RS-422/485

(330 /OPEN/110)

15)

Ethernet communication status LED

SD RD: Turns on in green during data communication,

100M:Turns on in green during 100Mbps transmission.

16)

17)

Ethernet interface

Hole for unit installation fitting

For connecting the equipment through Ethernet

(RJ-45 connector)

Hole for the inserting installation fittings (accessory) during the GOT installation to the panel

(4 holes at top and bottom)

For the connection to the controller (PLC, microcomputer board, bar code reader,

RFID, etc) or PC, refer to the following.

GT14 User’s Manual

3. Specifications

3.1 General Specifications

Operating ambient temperature

Item Specifications

Display section 0 to 50 C

Other than display section 0 to 55 C (When mounted horizontally), 0 to 50C (When mounted vertically)

Storage ambient temperature

Operating ambient humidity

Storage ambient humidity

-20 to 60 C

10 to 90% RH, non-condensing (STN liquid crystal type to be stored at or below 39 C WBT.)

10 to 90% RH, non-condensing (STN liquid crystal type to be stored at or below 39 C WBT.)

Vibration resistance

Shock resistance

Operating atmosphere

Conforms to JIS

B3502 and

IEC61131-2

Under intermittent vibration

Under continuous vibration

Frequency

5 to 8.4Hz

8.4 to 150Hz

5 to 8.4Hz

8.4 to 150Hz

Acceleration

--

9.8m/s

--

4.9m/s

2

2

Half-amplitude

3.5mm

Conforms to JIS B3502, IEC 61131-2 (147 m/s 2 , 3 times each in X, Y and Z directions)

--

1.75mm

--

Sweep Count

10 times each in X,

Y and Z directions

Must be free of lamp black, corrosive gas, flammable gas, or excessive amount of electro conductive dust particles and must be no direct sunlight. (Same as for saving)

Operating altitude *1

Installation location

Overvoltage category *2

Pollution degree

Cooling method

*3

2000 m (6562 ft) max.

Inside control panel

 or less

2 or less

Self-cooling

*1 Do not use or store the GOT under pressure higher than the atmospheric pressure of altitude 0m (0ft.). Failure to observe this instruction may cause a malfunction.

When the air inside the control panel is purged by pressurization, the surface sheet may be lifted by high pressure. As a result, the touch panel may be difficult to press, and the sheet may be peeled off.

*2 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within the premises.

Category  applies to equipment for which electrical power is supplied from fixed facilities.

The surge voltage withstand level for up to the raged voltage of 300 V is 2500 V.

*3 This index indicates the degree to which conductive material is generated in the environment where the equipment is used.

In pollution degree 2, only non-conductive pollution occurs but temporary conductivity may be produced due to condensation.

3.2 Performance Specifications

Display section *1

Backlight

To u c h panel

*4

Type

Item

Screen size

Resolution

Display size

Display character

Display color

GT1455-QTBD(E)

TFT color liquid crystal

5.7"

320  240 dots

W115(4.53)  H86(3.39)[mm](inch) (Horizontal format)

16-dot standard font: 20 characters

Specifications

GT1450-QMBD(E)

TFT monochrome (white/black)

liquid crystal

GT1450-QLBD(E)

STN monochrome (white/black)

liquid crystal

 15 lines, 12-dot standard font: 26 characters  20 lines

Display angle *2

Contrast adjustment

Intensity of LCD only

Intensity adjustment

Life

65536 colors Monochrome (white/black), 16 scales

Left/Right: 80 degrees, Top: 80 degrees, Bottom: 60 degrees (Horizontal format)

Left/Right: 45 degrees,

Top: 20 degrees,

Bottom: 40 degrees (Horizontal format)

32-level adjustmen --

400[cd/m

2

] 300[cd/m

2

]

8-level adjustment

Approx. 50,000h. (Time for display intensity to become 1/5 at operating ambient temperature of 25 C)

Life

Type

Key size

N u m b e r o f p o i n ts t o u c h e d simultaneously

LED (irreplaceable by a user) Backlight off/screen saving time can be set.

*3

Approx. 70,000h or longer (Time for display intensity reaches 50% at the operating ambient temperature of 25

Analog resistive film touch panel

Minimum 2  2 dots (per key)

Simultaneous presses not allowed. (Only 1 point can be touched.)

C)

Memory

Battery

Life

C drive *5

1 million times or more (operating force 0.98N max.)

Flash memory (Internal), for storing project data (9Mbytes) and OS

D drive

Life (Number of write times) 100,000 times

SRAM (Internal), 512kbytes (battery backup)

Type

GT11-50BAT lithium battery

Magnesium maganese dioxide lithium primary battery

Backup target

Life

Clock data, alarm history, recipe data, time action setting value, advanced alarm/advanced recipe, logging, hardcopy and

SRAM user area

Approx. 5 years (Operating ambient temperature of 25 C)

Built-in interface

RS-232

Item

RS-422/485

Ethernet

(Only in models equipped with

Ethernet interface)

USB

Host

Device

SD card

GT1455-QTBD(E)

Specifications

GT1450-QMBD(E)

RS-422/485 1ch

Transmission speed : 115,200/57,600/38,400/19,200/9,600/4,800bps

Connector shape

Application

: D-sub 9-pin (Female)

: PLC communication

Terminating resistor : Open/110 /330 (Switched by terminating resistor selector switch) *6

(At factory shipment: 330 )

GT1450-QLBD(E)

RS-232 1ch

Transmission speed : 115,200/57,600/38,400/19,200/9,600/4,800bps

Connector shape

Application

: D-sub 9-pin (Male)

: PLC communication, bar code reader, RFID connection, PC communication

(Project data upload/download, OS installation, transparent function)

Data transfer method: 100BASE-TX/10BASE-T, 1ch

Connector shape : RJ-45 (Modular jack)

Application : PLC communication, Gateway functions, PC communication

(Project data upload/download, OS installation, FA transparent function)

USB (Full Speed 12Mbps), 1ch

Connector shape

Application

: TYPE-A

: Data transfer, data storage

USB (Full Speed 12Mbps), 1ch

Connector shape

Application

: Mini-B

: PC communication (Project data upload/download, OS installation, FA transparent function)

In conformance to SD standard, 1ch

Applicable memory cards : SDHC memory card, SD memory card

Application : Project data upload/download, OS installation, logging data storage

Single tone (tone length adjustable)

Equivalent to IP67 (front section)

W164(6.46)  H135(5.32)  D55(2.17)[mm](inch)(Excluding USB environmental protective cover) (Horizontal format)

W153 (6.03)  H121(4.77)[mm] (inch) (Horizontal format)

Approx.

0.7kg (Excluding mounting fixtures)

GT Designer3 Version1.37P or later GT Designer3 Version1.118Y or later GT Designer3 Version1.37P or later

Buzzer output

Environmental protective structure

*7

External dimensions

Panel cutting dimensions

Weight

Compatible software package

*1 • Bright dots (always lit) and dark dots (unlit) may appear on a liquid crystal display panel. It is impossible to completely avoid this symptom, as the liquid crystal display comprises of a great number of display elements.

Flickers may be observed depending on the display color.

Please note that these dots appear due to its characteristic and are not caused by product defect.

• Flickers and partial discoloration may be generated on the liquid crystal display panel due to the display contents or the contrast adjustment.

However, please note that these phenomena appear due to its characteristic and are not caused by product defect.

• There is a difference in the display brightness and the color tones between liquid crystal display panels. When using multiple liquid crystal display panels, please note that there is an individual difference between them.

• A crosstalk (shadow as an extension of the display) may appear on the liquid crystal display panel. Please note that it appears due to its characteristic.

• When the display section is seen from the outside of the display angle, the display color seems like it has changed. Please note that it is due to its characteristic.

Please note that the response time, brightness and color of the liquid crystal display panel may vary depending on the usage environmental temperature.

Especially in the low temperature environment, the display response becomes slow due to the characteristics of the STN liquid crystal.

Please check the display response in advance for using this product.

• When the same screen is displayed for a long time, an incidental color or partial discoloration is generated on the screen due to heat damage, and it may not disappear.

To prevent heat damage, the screen saver function is effective.

For details on the screen saver function, refer to the following.

GT14 User's Manual

• Just after the GOT is powered off, sometimes an image lag or partial discoloration is generated temporary. However they are caused by the characteristic of the liquid crystal. (After powering off, they disappear within a few minutes.)

*2 Gradation inversion is a characteristic of liquid crystal displays.

Please be forewarned that depending on the displayed color, the visualization may be difficult even within the described view angle.

*3 Using the GOT Backlight OFF function can prolong the life of the backlight.

For details on the Backlight OFF function, refer to the following.

GT14 User's Manual

*4 The touch panel is analog resistive film-type. If you touch the panel simultaneously in 2 points or more, the switch that is located around the center of the touched point, if any, may operate. Do not touch the panel in 2 points or more simultaneously. Do not press the GOT display section with a pointed material as a pen or driver. Doing so can result in a damage or failure of the display section. For the analog-resistive film type touch panels, normally the adjustment is not required. However, the difference between a touched position and the object position may occur as the period of use elapses. When any difference between a touched position and the object position occurs, execute the touch panel calibration. When any difference between a touched position and the object position occurs, other object may be activated.

This may cause an unexpected operation due to incorrect output or malfunction.

*5 ROM in which new data can be written without deleting the written data.

*6 Set the terminating resistor selector switch of the GOT in accordance with the connection type when adopting GOT multidrop connection.

For details of GOT multidrop connection, refer to the following.

GOT1000 Series Connection Manual

*7 Compliant with IP67 when the USB environmental protection cover is attached. Not compliant when a USB cable is connected. Note that this does not guarantee all users' operation environment. The protection is not applied when the interface environment protection cover is removed.

In addition, the product may not be used in environments under exposition of oil or chemicals for a long period of time, or in environments filled with oil-mist.

Appearance

White stripe patterns may appear on the surface of the resin molded part of the product. Please note that these phenomena appear due to the characteristics of the material used in the product and are not caused by product defect.

3.3 Power Supply Specifications

Item

Input power supply voltage

Fuse (built-in, not exchangeable) 1.6A

GT1455-QTBD, GT1450-QMBD, GT1450-QLBD

24VDC (+10% -15%), ripple voltage 200mV or less

Specifications

GT1455-QTBDE, GT1450-QMBDE, GT1450-QLBDE

Item

Power consumption

At backlight off

Inrush current

Permissible instantaneous power failure time *1

Noise immunity

Dielectric withstand voltage

Insulation resistance

Applicable wire size

Applicable solderless terminal

Applicable tightening torque

(Terminal block terminal screw)

GT1455-QTBD, GT1450-QMBD, GT1450-QLBD

7.68W (320mA/24VDC) or less

6.72W (280mA/24VDC) or less

30A or less (26.4V) 2ms

Within 5ms

Noise voltage: 1000Vp-p, Noise width: 1 s (by noise simulator of 30 to 100Hz noise frequency)

500VAC for 1 minute (across power supply terminals and earth)

10M  or larger by insulation resistance tester (across power supply terminals and earth)

For power supply: 0.75[mm 2 ] or more, For grounding: 2[mm 2 ] or more

Solderless terminal for M3 screw RAV1.25-3, V2-N3A, FV2-N3A

0.5 to 0.8[N

 m]

Specifications

GT1455-QTBDE, GT1450-QMBDE, GT1450-QLBDE

8.40W (350mA/24VDC) or less

7.44W (310mA/24VDC) or less

*1 The GOT continues to operate even upon 5ms or shorter instantaneous power failure.

The GOT stops operating if there is extended power failure or voltage drop, while it automatically resumes operation as soon as the power is restored.

3.4 External Dimensions

164 (6.46")

22

(0.87") 120 (4.73")

23 (0.91")

22

(0.87")

120 (4.73")

152 (5.99")

4. Installation

4.1 Control Panel Inside Dimensions for Mounting GOT

Mount the GOT onto the control panel while considering the following control panel inside dimensions.

30 (1.19") 152 (5.99")

1)

Unit: mm (inch)

No

1)

Name

PLC connection cable/PC connection cable

Applicable cable

Some cables may need to be longer than the specified dimensions when connecting to the GOT. Therefore, consider the connector dimensions and bending radius of the cable as well for installation.

#4-40UNC

(inch screw type)

M2.6

(Metric screw type)

Panel thickness: 2 to 4mm

(0.07" to 0.15") or less

Unit: mm (inch)

4.2 Panel Cutting Dimensions

Make holes in the panel according to the dimensions list below.

Also, ensure 10mm spaces in upper and lower parts of the panel for mounting fixtures.

153

-

+ 2

0

( 6.03" )

10 (0.4") or more

0.08" 0

+ -

Panel thickness: 2 to 4mm

(0.07" to 0.15" inch)

10 (0.4") or more

Unit: mm (inch)

4.3 Mounting Position

When mounting the GOT, the clearances shown on the right must be left from a structure or the other device.

Installation

Environment

In the presence of radiated-noise or heat-generating equipment nearby

In the absence of radiated-noise or heat-generating equipment nearby

A,D

50 mm

(1.97”) or more

20 mm

(0.79”) or more

B

80 mm

(3.14”) or more

20 mm

(0.79”) or more

*1 Vertical format....50 mm (1.97”) or more

*2 Vertical format....80 mm (3.14”) or more

*1

C

50 mm

(1.97”) or more *2

20 mm

(0.79”) or more

E

100 mm

(3.93”) or more

20 mm

(0.79”) or more

C

Panel thickness: 2 to 4mm

(0.07" to 0.15" inch)

4.4 Control Panel Inside Temperature and Mounting Angle

When mounting the main unit to a control panel or similar, set the display section as shown below.

When the temperature inside the control panel is 40 to 55 C (Horizontal mount),

40 to 50 C (Vertical mount), the mounting angle should be in the range 60 to

105  degrees.

 The GOT will be deteriorated earlier if it is used at the mounting angle other than the above.

Therefore, the temperature inside the control panel should be within 40 C.

GOT display section

GOT back panel

60 °

105 °

Control panel, etc.

4.5 Installation Procedure

The GOT is designed to be embedded into a panel. Mount the GOT by following the procedure below. For panel cutting dimensions, refer to Section 4.2. Note that the panel thickness should be within 2 to 4mm.

1) Installing the packing

Packing

Install packing to the packing installation groove on the back panel of the GOT.

W h i l e r e f e r r i n g t o t h e c r o s s sectional view of the packing shown right, push the thinner side into the packing groove.

(Right drawing is the example of lateral format.)

Magnified illustration

Packing

Packing installation groove

Packing cross sectional view

Inserting direction

2) Inserting into the panel face

Insert the GOT from the front side of the panel.

3) Fixing the GOT

Engage the hook of the mounting fitting (accessory) to the unit fixing hole of the GOT and tighten the screw until the GOT is fixed with the mounting bolt (accessory).

The GOT will be fixed in 4 upper/ lower parts.

Tighten the mounting screw with the specified torque.

(Failure to do so may distort the p a n e l a n d m a k e a s u r f a c e waviness on the protective sheet.)

4) A protection film is attached on the display section of GOT prior to shipment. Remove the film when the installation is completed.

D

E

Mounting hole

Magnified illustration

Mounting fitting

Mounting screw

5. Wiring

5.1 Power Supply Wiring

Connect the power supply to the power terminals on the back panel of the GOT.

Use 0.75mm

2 or thicker cables to avoid voltage drop and tighten the terminal screw with the specified torque securely.

PC and external device connection cables

Power supply terminal

Grounding

(100W or less)

+

-

24VDC power supply

 Carry out the independent grounding if possible.

 If the independent grounding is impossible, carry out the shared grounding as shown in fig.2) below.

 Use the cable of 2mm 2 or more for grounding.

Set the grounding point closer to the GOT to make the grounding cable short as possible.

GOT

Other device

Grounding

(100W or less)

GOT

Grounding

(100W or less)

Other device

(1) Independent ground

...... Best condition

(2) Shared grounding

...... Good condition

1) Recommended terminal shape

3.2

Terminal screw

Solderless terminal

6.2mm or less

3.2

6.2mm or less

GOT

(3) Common grounding

...... Not allowed

Terminal screw

Other device

Solderless terminal

When wiring one cable to one terminal

When wiring two cables to one terminal

Applicable solderless terminal RAV 1.25-3, V2-N3A and FV2-N3A

6. Maintenance and Inspection

The GOT does not include consumable components that will cause the shorten life.

However, note that battery life is 5 years and LCD life is 50,000 hours. The life of backlight is 70,000 hours.

It is recommended to replace the battery periodically. (For the replacement of the liquid crystal screen and backlight, please consult your nearest sales office or FA Center.)

6.1 Daily Inspection

Daily inspection items

No.

1

2

Inspection Item

GOT mounting status

Inspection

Method

Check for loose mounting screws.

Loose terminal screws

Retighten screws with screwdriver

Proximate solderless terminals Visual check

Criterion

Securely mounted

Not loose

Proper intervals

Action

Retighten screws within the specified torque range

Retighten terminal screws

Correct

Loose connectors

Dirt on protection sheet

Visual check

Visual check

Not loose

Not outstanding

Retighten connector fixing screws

Replace with new one

3

Foreign material attachment

Visual check

No foreign matter sticking Remove clean

Refer to the following for the model names of the protection sheet or the replacement procedure.

GT14 User’s Manual

6.2 Periodic Inspection

Yearly or half-yearly inspection items

The following inspection should also be performed when equipment has been moved or modified or the wiring changed.

No.

Inspection Item

Inspection

Method

1

Ambient temperature

Surrounding environment Ambient humidity

Atmosphere

Make measurement with thermometer or hygrometer

Measure corrosive gas

Criterion Action

Display section

Other portions

No corrosive gas

0 to

50 C For use in control

0 to

55 C panel, temperature

10 to 90%RH inside control panel is ambient temperature

No.

2

Inspection Item

Power supply voltage check

Inspection

Method

24VDC

Measure voltage across terminals.

Criterion

20.4 to

26.4VDC

Action

Change supply power

3

4

Mounting status

Connection status

Looseness

Dirt, foreign matter

Loose terminal screws

Proximate solderless terminals

Move module

Visual check

Retighten screws with screwdriver

Visual check

Should be mounted firmly Retighten screws

No dirt, foreign matter sticking Remove, clean

Not loose

Proper intervals

Retighten terminal screws

Correct

5 Battery

Loose connectors

Visual check Not loose

Check the voltage status of the GOT built-in battery of [Time

Setting & display] in the

Utility.

No alarm displayed

Retighten connector fixing screws

Replace with new battery when the current battery has reached the specified life span, even if battery voltage is not displayed.

6.3 Battery Replacement

The battery is used for backing up the clock data, alarm history, recipe data, time action setting value, advanced alarm, advanced recipe, logging, hardcopy or SRAM user area. Screen data is stored in the flash memory and data is retained even if the battery is dead.

 Battery model name

GT14 is shipped with the following battery.

Product name

Battery

 Battery replacement procedure

1) Turn the GOT power off.

2) Open the battery cover of the GOT.

3) Remove the old battery from the GOT.

4) Disconnect the old battery connector and insert the new battery connector within 30s.

5) Insert the new battery into the GOT and close the battery cover.

6) Turn the GOT power on.

7) Check if the battery condition is normal with the utility.

Refer to the following for the details of battery status display.

GT14 User’s Manual

Model name

GT11-50BAT

Connector

Battery cover

Battery cover

 How to confirm production year and month

Connector

The production year and month of the battery built in the purchased GOT can be confirmed by the production No. (S/N) marked on the GOT main unit.

Example nameplate (manufacture's serial number 1160003)

* Actual product

nameplate differs from

the shown on the left.

7-digit

1 1 6 0 0 0 3

Control number

Month (example: Jun.), 1 to 9: Jan. to Sep.,

X: Oct., Y: Nov., Z: Dec.

Year (example: 2011) Last two digit of year

The production date of the optional replacement battery can be confirmed by the lot

No. marked on the nameplate (label) affixed on the battery.

Name plate

Model name

LOT.

GT11-50BAT

LOT.116

Connector

3-digit

1 1 6

Month

(example: Jun.)

1 (Jan.) to 9 (Sep.),

X (Oct.), Y (Nov.), Z (Dec.)

Year (example: 2011)

Last two digit of year

 Battery life

Approximate battery life:

5 years (ambient temperature: 25 C)

Battery replacement: In 4 to 5 years

Approximate life is 5 years, but life may be shorter depending on the ambient temperature, therefore, note that the battery must be replaced in 4 to 5 years. Make sure to purchase a new battery as needed as it self-discharges.

Battery status can be confirmed on a GOT utility screen.

For details of battery status or how to output alarm, refer to the following:

GT14 User’s Manual

7. Notification of CE marking

The following products have shown compliance through direct testing (to the identified standards) and design analysis (forming a technical construction file) to the European Directive for Electromagnetic Compatibility

(2004/108/EC) when used as directed by the appropriate documentation.

 This product is designed for use in industrial applications.

 Authorized Representative in the European Community: Mitsubishi Electric

Europe B.V. Gothaer Str. 8, 40880 Ratingen, Germany

- Type: Graphic Operation Terminal

- Models: GOT series

Standard

EN61131-2 : 2007

Programmable controllers

- Equipment, requirements and tests

EMI

EMS

Remark

Compliance with all relevant aspects of the standard.

(Radiated Emissions)

Compliance with all relevant aspects of the standard.

(ESD,RF electromagnetic field, EFTB, Surge, RF conducted disturbances and Power frequency magnetic field)

For more details please contact your local Mitsubishi Electric sales site.

For details of CE marking, refer to the following.

GT14 User's Manual

7.1 Notes regarding the use of GOT units

7.1.1

General notes on the use of communication cables

Any device which utilizes a data communication function is susceptible to the wider effects of local EMC noise. Therefore, when installing any communication cables care should always be taken with the routing and location of those cables.

Optional ferrite cores are recommended when the cable route is close to EMC noise sources like welders, large motors, etc. All tests have been performed with original Mitsubishi cables. For customer prepared cables, please refer to the manuals.

GOT Unit

All units

Ex.1

Existing Cables

Ex. GT01-C30R4-8P (as shown in EX.1)

A complete list of appropriate cables can be found in the GOT user's manual.

250mm

GT01-C30R4-8P

100mm

User Made Cables

3rd party cables need to be independently tested by the user to demonstrate EMC compliance.

Ex.2

Programmable controller

F F

140mm

Optional

Comes equipped

F

Optional

F = Ferrite core

Ex. Tokin-ESD-R-17S or similar

7.1.2

General notes on power supply

All units require an additional ferrite filter to be attached to the 24V DC power supply cables. The filter should be attached in a similar manner as shown in the figure opposite, i.e. the power cables are wrapped around the filter. However, as with all EMC situations the more correctly applied precautions the better the system's electromagnetic compatibility. The ferrite recommended is a TDK

ZCAT3035-1330 or similar (shown in Ex.2). The ferrite should be placed as near to the 24V DC terminals of the all units as possible (which should be within 75mm of the GOT terminal).

Note: The customer must evaluate conformance of the final produced unit with the EMC directive.

8. Certification of UL, cUL standards

 Environmental rating

Front: Type 4X (indoor use only)

 Using GOT

GOT is for use on a flat surface of a Type 1 or Type 4X (indoor use only) enclosure

This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.

Warranty

Exclusion of loss in opportunity and secondary loss from warranty liability

Regardless of the gratis warranty term, Mitsubishi shall not be liable for compensation to:

(1) Damages caused by any cause found not to be the responsibility of

Mitsubishi.

(2) Loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi products.

(3) Special damages and secondary damages whether foreseeable or not, compensation for accidents, and compensation for damages to products other than Mitsubishi products.

(4) Replacement by the user, maintenance of on-site equipment, start-up test run and other tasks.

For safe use

This product has been manufactured as a general-purpose part for general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life.

Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with

Mitsubishi Electric.

This product has been manufactured under strict quality control. However when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system.

HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

advertisement

Key Features

  • 5.7" TFT color liquid crystal display
  • 320 x 240 dot resolution
  • High-speed monitoring via serial communication and Ethernet
  • Built-in flash memory for project data storage
  • Supports SD card and USB interfaces
  • RS-232, RS-422/485 and Ethernet communication interfaces
  • Battery backup for data retention
  • Touch panel for user interaction
  • Unicode2.1-compatible fonts for multi-language support
  • TrueType and high-quality fonts for improved display quality

Frequently Answers and Questions

What is the operating ambient temperature range for the GOT touch screen?
The operating temperature range for the display section is 0 to 50°C, and for other sections, it is 0 to 55°C when mounted horizontally and 0 to 50°C when mounted vertically.
What is the battery backup time for the GOT touch screen?
The battery backup time is approximately 5 years when the operating ambient temperature is 25°C.
What is the maximum operating altitude for the GOT touch screen?
The maximum operating altitude for the GOT touch screen is 2000m (6562ft).

Related manuals