The DATAIR 400/M3 is a handheld device for testing and troubleshooting ARINC 429 avionics systems. It allows the user to connect to an ARINC 429 data bus and easily view the active ARINC 429 Labels on the bus or to generate a series of test words to simulate a specific test. The device features a backlit LCD, an alphanumeric keypad, an ARINC 429 receiver, and a transmitter board. It also includes a detachable rechargeable battery pack. The DATAIR 400/M3 is an ideal first line diagnostic tool for technicians who need to test and troubleshoot ARINC 429 systems.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
DATAIR - 400/M3 ARINC-429 TESTER
User Manual
YED Avionics Limited
Park House
10, Park Street
Bristol
Avon, BS1 5HX
UK
Tel: +44 (0)117 907 4761 e-mail: [email protected]
Web: www.yed.com
Disclaimer
All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of the product for their particular application. YED
Avionics Limited (YED) make no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. YED's only obligations are those contained in the Standard Terms and Conditions of Sale for this product and in no case will YED be liable for any incidental, indirect or consequential damages arising from the sale, resale, use or misuse of the product.
Furthermore, it shall be understood by the user that the product supplied is intended for use as first line Diagnostic Test
Equipment and shall under no circumstances be used to certify or calibrate flight or mission critical equipment.
This document is proprietary to YED and is not to be reproduced or otherwise disseminated without the written consent of YED.
YED Avionics Limited
Park House
10, Park Street
Bristol
Avon, BS1 5HX
U.K.
Revision History
Date
Changes Made
Issue Initials
24/03/15
First Release
16/06/15
12/07/15
14/08/15
3.3.5.1 thru 3.3.5.3 added. Examples of entering differing engineering formats for BCD and BNR.
1.5: Caution about not operating the unit whilst charging the battery pack in-situ.
D9 ARINC 429 Tx+ and Tx- connections swapped.
Firmware upgrade procedure added.
13/10/15
Declaration of Conformity title added.
1.0
1.1
1.1a
1.2
1.2a
GB
GB
GB
GB
GB
GENERAL WARNINGS AND CAUTIONS APPLICABLE TO THIS
EQUIPMENT
BATTERY CHARGING WARNING
This equipment has a recharging circuit for rechargeable battery pack. Use only YED supplied battery packs and ONLY use the supplied charger. Do not operate the instrument whilst recharging the battery unless the battery pack is removed from the instrument.
CLEANING WARNING
Keep the equipment dry to avoid electrical shock to personnel or damage to the equipment.
To prevent damage, never apply solvents to the equipment housing. For cleaning, wipe the equipment with a cloth that is lightly dampened with water, mild detergent, or alcohol.
Table of Contents
1.
INTRODUCTION ................................................................................................................................. 5
1.1
G
ENERAL
................................................................................................................................................. 5
1.2
E
QUIPMENT
D
ESCRIPTION
......................................................................................................................... 5
1.3
T
ECHNICAL
S
PECIFICATION
...................................................................................................................... 6
1.4
S
UPPLIED ACCESSORIES
............................................................................................................................ 7
1.5
R
ECHARGEABLE BATTERY PACK
................................................................................................................ 7
1.6
K
EYPAD
................................................................................................................................................... 7
2.0
OPERATION ........................................................................................................................................ 8
2.1
P
OWERING
O
N
/O
FF
S
WITCH
..................................................................................................................... 8
3.0
MENU STRUCTURE ........................................................................................................................... 9
3.1
R
OOT
M
ENU
.......................................................................................................................................... 10
3.2
R
ECEIVE
M
ENU
& B
INARY
M
ONITOR SCREEN
.......................................................................................... 11
Notes ..................................................................................................................................................................... 11
3.2.1
Receive Monitor & Engineering units screen ............................................................................... 12
Notes ..................................................................................................................................................................... 12
3.3
T
RANSMIT
M
ENU
................................................................................................................................... 12
3.3.1
CLEAR ALL TX LABELS ............................................................................................................. 13
3.3.2
SELECT ALL TX LABELS............................................................................................................ 14
3.3.2.1
ERROR: Too many labels enabled. .................................................................................................... 14
3.3.3
SELECT LABELS TO TX and Label rates .................................................................................... 15
3.3.4
SET GLOBAL TX RATE ............................................................................................................... 15
3.3.5
SHOW / EDIT TX VALUES .......................................................................................................... 17
3.3.5.1
Entering values for BCD formatted words. ......................................................................................... 19
3.3.5.2
Entering values for BNR formatted words. ......................................................................................... 19
3.3.5.3
Entering values for BNR “Special” formatted words. ......................................................................... 19
3.3.6
MODE: Setting the Transmitter mode .......................................................................................... 20
3.3.7
TX IS: Starting / Stopping the Transmitter ................................................................................... 21
3.4
LOAD A DATABASE .......................................................................................................................... 22
3.4.1
PROFILES ................................................................................................................................... 23
3.5
C
USTOM
L
ABEL
D
EFINITIONS
................................................................................................................. 25
3.5.1
VIEW / EDIT LABEL ................................................................................................................... 26
3.5.2
SUSPEND CUSTOM LABEL ....................................................................................................... 27
3.5.3
DELETE CUSTOM LABEL .......................................................................................................... 29
3.2
RS232 C
ABLE
C
ONNECTIONS
................................................................................................................. 30
4.0
PERFORMING A FIRMWARE UPDATE ........................................................................................ 31
FCC REGULATIONS ................................................................................................................................. 36
YED Avionics Ltd
DATAIR-400/M3 ARINC 429 TESTER
1. INTRODUCTION
1.1 General
This manual provides operational information for the DATAIR-400/M3 handheld ARINC 429
Tester.
1.2
Equipment Description
The DATAIR-400/M3 is aimed at providing the user with an easy to use first line diagnostic tool for testing and troubleshooting ARINC 429 avionics systems. It allows the user to connect to an
ARINC 429 data bus and easily view the active ARINC 429 Labels on the bus or to generate a series of test words to simulate a specific test.
The DATAIR-400/M3 ARINC 429 Tester is a Hand Held unit that comprises an 8 line by 21 character backlit LCD, an alphanumeric keypad, a microprocessor controlled ARINC 429 receiver, transmitter board with a detachable rechargeable battery pack.
Receiver features:
Rx Independent internal ARINC 429 Engineering units definitions as per ARINC 429-16
User definable and customised ARINC 429 label definitions – with save, suspend and delete.
Selectable Hex Equipment ID for reception and display of received ARINC 429 data words
Independent user configuration profiles for Tx operations
Automatic preservation of setup between power downs
Data display in Hexadecimal, binary and Engineering Units
Individual display of bits 11 through 29,
Display of SSM, SDI (with SDI filtering or don’t care) and Parity
Automatic reception of Lo or Hi ARINC 429 bit rates
Display of received bit rate as “Hi” (100kHz) or “Lo” (12.5kHz)
Display of interval of received label in mS.
Transmitter features:
Tx Independent internal ARINC 429 Engineering units definitions as per ARINC 429-16
User definable and customised ARINC 429 label definitions – with save, suspend and delete.
Selectable Hex Equipment ID for transmission and data entry ARINC 429 data words
Independent user configuration profiles for Tx operations
Data entry in binary or Engineering Units
On/Off toggling of individual data bits 11 through 29
Editable SSM field values.
Editable Parity
Real time update of transmitted data
Transmission of up to 150 labels at user selectable repetition rates.
Individual label transmission interval (10,20,50,100,200,500 and 1000 mS) word rates
Single shot mode
Selectable (Lo or Hi speed) bit rate
Non-volatile memory storage
PAGE 5 of
36
User Manual Issue 1.2a
YED Avionics Ltd
Other features:
DATAIR-400/M3 ARINC 429 TESTER
An 8-line by 21 character backlit Liquid crystal display.
Alpha-numeric keypad with navigation keys
USB/RS232 Firmware update capability for future enhancements.
Handheld portable Instrument.
Detachable rechargeable NimH battery (4.8V @ 2100mAH). 8 Hour use from full charge
Available with universal 110 V / 220 V ac battery charger
Can be powered from external DC 6V DC power supply
Standard D9 connector with test leads for connecting to ARINC 429 system
1.3 Technical Specification
ARINC 429 Receiver
Input:………………………………………………………………………. Opto-coupler isolated input
Voltage levels (Line A to B):………………………………………. HI
NULL
LO
ARINC 429 Transmitter
Output:……………………………………………………………………. Industry standard line driver
Mass
Output impedance:………………………………………………….. 75 ±5 Ω (Line A to B)
Voltage levels (Line A to B):………………………………………. HI +10V ±1V
NULL
LO
Bit rate: ………………………………………………………………….. Low Speed:
0.0 to ±0.5V
-10V ±1V
12.5kbps ±0.5%
High Speed: 100.0 kbps ±0.5%
Word rate:…………………………………………………………… 10 to 1000mS
Parity: …………………………………………………………………. ODD
Bit rate: ………………………………………………………………….. Low Speed:
+6 to 12V
+2.5 to -2.5V
-6 to -12V
8 to 18kbps
High Speed: 80 to 125kbps
Weight:…………………………........................................….. 0.55kg
Dimensions:……………………………….……………………..……. 22.9H x 9.7W x 5.4D CM
Power requirements
Input: …………………………………………………………………….. 6V DC external power OR
Environmental
4.8V @ 2200mAH NiMH battery
Operating temperature:………………………………………….. 0 to 50 °C (Indoor use only)
Relative Humidity:……………………………………………….. 0% to 85%
Issue 1.2a User Manual 6 of 36
YED Avionics Ltd
DATAIR-400/M3 ARINC 429 TESTER
1.4 Supplied accessories
The DATAIR-400/M3 Tester is supplied with a universal 110VAC/240VAC battery charger.
One ARINC 429 Test Lead pair for connecting to an ARINC 429 Tx system and one pair for connecting to an ARINC 429 Rx system. In addition there is a firmware update cable (D9 to
D9) for updating the firmware when new a new upgrade is available via our website.
1.5 Rechargeable battery pack
The battery pack is supplied partially charged for safety reasons during transit. The battery pack should be fully charged using the supplied battery charger prior to first use. This should take no longer than 3 hours. The expected life of the battery from a full charge is 8 hours.
The unit should not be operated during charging as this will greatly affect the charging procedure. However the unit can be run on an external 6V DC power supply if the battery pack is removed whilst it is being charged.
1.6 Keypad
The keypad is the method used to navigate the menu system, display selection of options and alpha-numeric data entry and comprises the following keys:
Keys ⓿thru ❾ are for entering numeric data and also double for entering character entry.
ENT key is for confirming the previous data entry.
CLR key is used to abandon data entry and will usually return the user to the root of the menu.
↑↓←→
keys are used for navigating the menu and the various fields displayed on the LCD.
The
└┘ key can be used to insert a space when entering character strings.
The
+/-
is used to change the sign of an entered numeric value where supported. The polarity of certain ARINC 429 label data can only be changed by modifying the SSM field.
The following keys are reserved for future use:
F1
thru
F6
and the SYM key.
If you select an incorrect option then pressing the
←
key will move the Menu context back one level.
Pressing the CLR key will always position the context at the root menu.
PAGE 7 of
36
User Manual Issue 1.2a
YED Avionics Ltd
2.0 OPERATION
DATAIR-400/M3 ARINC 429 TESTER
2.1 Powering On/Off Switch
The slide switch is situated at the top end of the unit. Positions for ON and OFF are marked on the end plate of the unit.
When the unit is powered on the following screen will be displayed:
ARINC 429 TESTER
DATAIR-400/M3
Firmware Vx.x
YED Avionics & YED Limited
2015 www.yed.com
Press any key to advance to the Root of the menu.
Issue 1.2a User Manual 8 of 36
YED Avionics Ltd
DATAIR-400/M3 ARINC 429 TESTER
3.0 Menu structure
The design and layout of the menu is shown below. Navigation is via the use of the
↑↓←→ ,
ENT and CLR keys.
POR
Sign-On Screen
MAIN MENU
RECEIVE MENU
BUS SEARCH
RAW RX DATA
MONITOR DATA
TRANSMIT MENU
SEL TX LABELS &
TX RATES
SHOW/EDIT TX
LABEL DATA
TX MODE
TX RUN/STOP
DATABASE MENU
SELECT RX/TX
DATABASE
PROFILES
LABELS MENU
VIEW/EDIT TX/RX
DEFINITIONS
SUSPEND OR
ACTIVATE
CUSTOM LABELS
DELETE CUSTOM
LABELS
PAGE 9 of
36
User Manual Issue 1.2a
YED Avionics Ltd
DATAIR-400/M3 ARINC 429 TESTER
3.1 Root Menu
After advancing from the power on screen by pressing any key the root menu will be displayed where the four main menu options are presented as shown below.
MAIN MENU
RECEIVE (ID:002)
TRANSMIT (ID:002)
LOAD A DATABASE
LABEL DEFINITIONS
Four main options are available from here:
RECEIVE:
TRANSMIT:
Entry point into the receive menus
Entry point into the transmit menus
LOAD A DATABASE: Select a standard ARINC 429 database or saved profile
LABEL DEFINITIONS: For creating, editing or suspending custom label definitions
The (ID:002) indicates the currently loaded standard ARINC 429 definition. In this case Hex
ID 002 is loaded for both Tx and Rx.
To access a display option, use the
↑↓
and ENT keys.
If you select an incorrect option then pressing the
←
key will move the Menu context back one level.
Pressing the CLR key will always position the context at the root / top menu.
Issue 1.2a User Manual 10 of 36
YED Avionics Ltd
DATAIR-400/M3 ARINC 429 TESTER
3.2 Receive Menu & Binary Monitor screen
Pressing the ENT key whilst the [RECEIVE] option is high lit will cause the receive menu screen to appear. If the unit is connected to an active bus then a list of active Labels will be displayed as shown below. Pressing ENT selects a label to display in the Binary Monitor.
RECEIVE
RECEIVE MENU ID:002
010: Prs Pos Lat
011: Prs Pos Long
012: Ground Speed
013: Trk Angle True
014: <NoDef>
Bus Search screen
ENT
Press the ENT key to advance to the binary
Monitor screen
RECEIVE MENU ID:002
L=012 SSM=11 SDI=00
29………………………………………11
0000000000000000000
Hex: 60000040 P=0
Rate:102mS Sp: H
INC SDI FILTER
DEFINITION
PRESENT ?
ENT
FREEZE DATA
Rx Raw Data
Binary screen
N
Y
GOTO MONITOR
Press
↓
to advance the engineering display screen
Notes
INC SDI FILTER: Increments SDI value: 00,01,10,11,XX = Don’t care. SDI field is updated with current filter value. If SDI set to incorrect value then data will be displayed as “--------“.
If there is no data then “------“ will be displayed.
The SSM field is displayed here as ‘11’
The hexadecimal value and the binary values are displayed.
FREEZE DATA: Freezes display. Rate field is changed to “FROZEN” ENT Key toggles this mode.
Speed is “H” or “L” for 100kHz or 12.5kHz respectively.
Repetition rate of the received ARINC label is shown in mS.
PAGE 11 of
36
User Manual Issue 1.2a
YED Avionics Ltd
DATAIR-400/M3 ARINC 429 TESTER
3.2.1 Receive Monitor & Engineering units screen
From the previous screen, pressing the
↓
key will advance to the engineering display for the selected ARINC 429 Label and display its data field in engineering units format according to the standard or customer definition. This screen is only accessible for labels that have an
engineering unit definition.
MONITOR
GOTO RECEIVE
MONITOR MENU ID:002
L=002 Ground Speed
Val: 123.05 Knots
SDI=XX
ENT
INC SDI FILTER FREEZE DATA
Data Monitor screen
NEXT FIELD IF
PRESENT
Notes
INC SDI FILTER: Increments SDI value: 00,01,10,11,XX = Don’t care. SDI field is updated with current filter value. If SDI set to incorrect value then data will be displayed as “--------“. If there is no data then “------“ will be displayed.
FREEZE DATA: Freezes display. Rate field is changed to “FROZEN”. ENT Key toggles this mode.
Monitor menu screen shows that the Hex ID engineering units definitions loaded is 002.
Pressing the
CLR
returns to the top (root) menu.
Issue 1.2a User Manual 12 of 36
YED Avionics Ltd
DATAIR-400/M3 ARINC 429 TESTER
3.3 Transmit Menu
The transmit menu structure shown below comprises of four main options: SELECT LABELS
TO TX, SHOW/EDIT TX VALUES, MODE: (Single shot, continuous Lo speed, etc.) and TX IS
(Status is: Running or Stopped).
The Select Label to Tx menu option is ONLY available whilst the transmitter is not transmitting. Sub-menu options are provided for Selecting all or Clearing all Labels for transmission, Selecting individual Labels to transmit and their respective transmission rates or setting a Global rate for all the labels.
PAGE 13 of
36
User Manual Issue 1.2a
YED Avionics Ltd
DATAIR-400/M3 ARINC 429 TESTER
3.3.1 CLEAR ALL TX LABELS
Tx must be STOPPED. Selecting this option will unselect all Tx labels. This will be confirmed by the following screen.
TX LABELS
NO LABELS SELECTED
FOR TRANSMISSION
3.3.2 SELECT ALL TX LABELS
Tx must be STOPPED. Selecting this option will select all Tx labels in the active Engineering units database for transmission.
TX LABELS
ALL LABELS SELECTED
FOR TRANSMISSION
3.3.2.1 ERROR: Too many labels enabled.
If however the rates of the combined Labels in the transmission table exceed the available time due to a Low transmit bit rate setting or too many labels enabled then the following screen will be displayed.
TRANSMIT MODE
Too many labels enabled!
Labels not enabled.
Disable some labels and try again.
To remedy this problem use the “Set Global Tx Rate” menu option to set a slower Tx rate
(greater gaps between transmitted labels).
Issue 1.2a User Manual 14 of 36
YED Avionics Ltd
DATAIR-400/M3 ARINC 429 TESTER
3.3.3 SELECT LABELS TO TX and Label rates
Tx must be STOPPED. The purpose of this menu option is to select the labels to be transmitted and their transmission repetition rates. This option is only available when the transmitter is inactive.
The diagram below shows the screens for choosing which labels are to be selected for transmission. Highlight the required label and press the ENT key to toggle the selection denoted by the presence of the adjacent ‘*’ character. The ‘*’ adjacent to the label indicates that it is enabled. Pressing the
→
will allow the user to select the rate for the selected label.
Press ENT to exit from this screen.
PAGE 15 of
36
User Manual Issue 1.2a
YED Avionics Ltd
DATAIR-400/M3 ARINC 429 TESTER
3.3.4 SET GLOBAL TX RATE
Tx must be STOPPED. This option will allow the user to set ALL Tx Labels to a selected transmission rate. In this case 500mS as shown below.
Press ENT to exit from the lower screen.
Issue 1.2a User Manual 16 of 36
YED Avionics Ltd
DATAIR-400/M3 ARINC 429 TESTER
3.3.5 SHOW / EDIT TX VALUES
This menu option allows the user to enter real values for each label in the transmission list provided that it has an associated engineering unit definition. If a definition is not present for the selected label then it will only be possible to edit the binary value of the label being edited.
The Menu diagram is shown below.
PAGE 17 of
36
User Manual Issue 1.2a
YED Avionics Ltd
DATAIR-400/M3 ARINC 429 TESTER
Pressing ENT when the cursor is on the SHOW / EDIT TX VALUES option will cause the
SHOW TX VALUE screen to be presented. Using the
↑↓
keys scrolls the list of enabled labels for transmission. Once the label of interest is visible, pressing the ENT key will allow editing of the binary field. To toggle between the engineering edit field and the binary fields use the
↑↓
keys. Press the ENT key to fix the value. The SSM, SDI and Parity fields are also editable by use of the navigation keys
↑↓←→
.
Issue 1.2a User Manual 18 of 36
YED Avionics Ltd
DATAIR-400/M3 ARINC 429 TESTER
3.3.5.1 Entering values for BCD formatted words.
The “Sign” of an entered value for a BCD formatted words can be altered by pressing the +/key. This key will toggle the value of the SSM between ‘11’ and ‘00’. This key changes the polarity of entered values including other variations such as N/S E/W where appropriate.
PLEASE NOTE When entering values for BCD formatted words, the exact number of required digits must be entered.
If a BCD field is defined as 5-digits wide then five digits must be entered to avoid rubbish being entered.
When accessing a data entry screen for a selected Label, press the ENT key to begin editing.
For a 4-digit formatted field the initialised engineering field will be shown as “0000”. The user would enter 4-digits like “1234”.
If the BCD field were formatted as NNN.N then the user would still enter four digits –
WITHOUT entering the decimal point. For this field format entering “1234” would result in
“123.4”.
3.3.5.2 Entering values for BNR formatted words.
The “Sign” of an entered value for standard BNR formatted words can be altered by pressing the +/- key. This key will toggle the value of Bit-29 between a ‘0’ and a ‘1’.
Unlike BCD words above the user does not have to adhere to the number of digits entered.
If you require to enter a value of “123.4” then you would press ‘1’ ‘2’ ‘3’ ‘.’ ‘4’. The decimal point button is active for BNR entry.
3.3.5.3 Entering values for BNR “Special” formatted words.
In the ARINC 429 specification, there are defined words that have to be treated in a special case. Example Labels are Labels 150 (GMT) 260 (date), 310 (Latitude) and 311 (Longitude).
Label 150 : GMT has three fields defined, Hours Minutes and Seconds.
Access the label in the usual way. Enter a time of “012359” will result in “1: 23.59” being displayed. The
←→
keys allow individual editing of the Hours, Minutes or Seconds fields.
Label 260 : Date is similar to the description for Label 150 above.
Label 310 and 311: Latitude and Longitude.
These two labels are special in that they are defined as degrees / 180.
If the user enters “45.5” degrees and presses ENT key the value displayed will be
“N45.499920”. In order to change the “N” (“E” for L311) to a “S” (“W” for L311) the user must move the cursor to hover over Bit-29 (Sign bit). Entering a ‘1’ will result in the value changing to “S134.50024”
PAGE 19 of
36
User Manual Issue 1.2a
YED Avionics Ltd
DATAIR-400/M3 ARINC 429 TESTER
3.3.6 MODE: Setting the Transmitter mode
This menu option sets the mode of transmission. There are four possible modes:
1. Continuous transmission at the High speed rate, 100kbp/s
2. Continuous transmission at the Low speed rate, 12.5kbp/s
3. Single Shot at the High speed rate,
100kbp/s
4. Single Shot at the Low speed rate,
12.5kbp/s
Continuous transmission means that it continue until the transmitted is switched off.
Single Shot mode means that every time the transmitted is set to
“RUNNING” the transmitter will transmit one iteration of the currently enabled transmitter list and then stop.
Issue 1.2a User Manual 20 of 36
YED Avionics Ltd
DATAIR-400/M3 ARINC 429 TESTER
3.3.7 TX IS: Starting / Stopping the Transmitter
This function sets the state of the transmitter to either transmitting or not transmitting.
If the Mode is set to “continuous” then the transmission will continue transmitting all enabled Tx labels until the transmitter is switched off. The transmitter state is toggled by pressing the ENT key.
If the Mode is “Single Shot” then each time the ENT key is pressed the transmitter will transmit one iteration of the enabled Tx Labels and then stop. The display will momentarily show “RUNNING” and then change back to “STOPPED”.
PAGE 21 of
36
User Manual Issue 1.2a
YED Avionics Ltd
DATAIR-400/M3 ARINC 429 TESTER
3.4 LOAD A DATABASE
This section loads the standard ARINC 429 Engineering Units Definitions files for Tx and Rx.
There can be a different database loaded for Rx and Tx. This section is also the entry point to for managing Profiles (see later section).
Using databases allows the user to interpret received data in meaningful engineering units formats such as Air speed in Knots, Altitude in Feet, etc. Otherwise the user would have to decode the raw binary data in order to decode the values. The same applies to entering real values for subsequent transmission.
The DATAIR-400/M3 is supplied with a compliment of standard definitions. Choose the definition in order to load the required definitions for your test requirements. For further information consult the ARINC 429 Specification. The “(ID:002)” shown in the screen refers to the loaded active definition.
Issue 1.2a User Manual 22 of 36
YED Avionics Ltd
DATAIR-400/M3 ARINC 429 TESTER
3.4.1 PROFILES
Profiles are used to hold different configurations that may be required to be saved by different users. Databases for Tx and Rx and the Label list configuration (enabled Tx labels, etc.) are typically saved in profiles. This saves the user from having to set up the instrument each time they need to conduct a test. Options available are Load, Save, Clear and Clear All
Profiles. When saving a new Profile the alpha-numeric keypad can be used to save a meaningful name (ie FMCU Test).
PAGE 23 of
36
User Manual Issue 1.2a
YED Avionics Ltd
The Clearing Profiles menu is shown below:-
DATAIR-400/M3 ARINC 429 TESTER
Issue 1.2a User Manual 24 of 36
YED Avionics Ltd
DATAIR-400/M3 ARINC 429 TESTER
3.5 Custom Label Definitions
In addition to the standard engineering units databases contained with the DATAIR-400/M3 the user may also customise the standard labels or create custom definition where a standard definition is unavailable. Customising a standard Label may be required when the width of the data field or the value of the field needs to be altered.
Once a custom Label has been created it can be made ‘Active’ so that it has priority over the standard definition. The custom Label can also be suspended so that the Standard Label become active once again.
If the custom Label is not required for future use then it can be permanently deleted.
PAGE 25 of
36
User Manual Issue 1.2a
YED Avionics Ltd
DATAIR-400/M3 ARINC 429 TESTER
3.5.1 VIEW / EDIT LABEL
This option allows the user to edit an edit or view an existing Label definition. Transmit or
Receive Labels should be selected from the first two choices. The currently shown loaded databases are both from HEX ID 002. Making a selection will take the user to the next screen where a list of currently defined Label are defined.
Label 002 is shown highlighted and pressing the ENT key will take the user to the Label edit screen on the next page.
As usual the
←
key will move the menu context back one level and the CLR key will move the menu context to the top level.
Issue 1.2a User Manual 26 of 36
YED Avionics Ltd
DATAIR-400/M3 ARINC 429 TESTER
VIEW / EDIT LABEL, continued
Below two labels are shown for editing having first been chosen from the previous menu screen. The Label on the left depicts a BCD coded label and the one on the right depicts a
BNR coded label.
If the user selected the “000: NEW DEFINITION” option from the previous menu screen then
Custom screen will be presented for the user to define the new Label definition.
PLEASE NOTE that after a Label has been modified or created the Label name will be presented in UPPER CASE to differentiate it from standard original definitions.
PAGE 27 of
36
User Manual Issue 1.2a
YED Avionics Ltd
DATAIR-400/M3 ARINC 429 TESTER
3.5.2 SUSPEND CUSTOM LABEL
In this menu option a list of any custom or modified Labels and the option to suspend, but not delete them will be presented. The ‘*’ adjacent to each custom label in the list denotes that they are active in the system and therefore override the standard definition. The ENT key may be used to toggle the ‘*’ active status of each label.
Issue 1.2a User Manual 28 of 36
YED Avionics Ltd
DATAIR-400/M3 ARINC 429 TESTER
3.5.3 DELETE CUSTOM LABEL
In this menu option a list of any custom or modified Labels is presented that can be selected and permanently deleted from the system memory. Use the ENT keys to scroll up and down the list of defined custom label to locate the one(s) to delete. Use the ENT key to delete each Label no longer required.
PAGE 29 of
36
User Manual Issue 1.2a
YED Avionics Ltd
DATAIR-400/M3 ARINC 429 TESTER
3.1 ARINC 429 connections
The DATAIR-400/M3 unit is fitted with an industry standard D-9 plug.
There are five connections:
RX ARINC +Ve Data :
RX ARINC -Ve Data :
TX ARINC -Ve Data :
TX ARINC +Ve Data :
Ground :
Pin 6
Pin 7
Pin 8
Pin 9
Pin 5.
3.2 RS232 Cable Connections
The following table lists the necessary connections for a suitable RS232 cable.
Wire 1
Wire 2
Wire 3
Wire 4
Wire 5
Wire 6
Wire 7
D9 DATAIR-400/M3 (1)
PIN
2 (Rx)
3 (Tx)
4
5
6
7
8
D9 Host PC (2)
PIN
3
2
6
5
4
8
7
Issue 1.2a User Manual 30 of 36
YED Avionics Ltd
DATAIR-400/M3 ARINC 429 TESTER
4.0 Performing a Firmware update
You will need to download the program “STMicroelectronics flash loader.exe” from our website at: http://www.yed.com/Downloads/stm32-stm8_flash_loader_demo.zip
Locate this program in a folder of your choice.
This program will load the update file into the FLASH memory on the DATAIR-400/M3.
This utility will run on a PC and will allow the reprogramming of the STM32F103 processor firmware with firmware e-mailed or downloaded from our website. This feature alleviates the necessity of a customer having to return their hardware to YED in order to have the firmware updated or modified under contract. The down load utility requires the use of an RS232 serial port on the host PC and this can include any suitable USB Serial port adapter.
Connection between the PC and the DATAIR-400/M3 unit is via the supplied D9 to D9 cable.
Procedure for updating the firmware is as follows:
1. With the DATAIR-400/M3 powered OFF, connect the cable end marked “DAT400” on the D9 connector back shell to the DATAIR-400/M3 and the other end to your RS232 port.
2. Switch the unit to ON
3. Start the “STMicroelectronics flash loader.exe” utility and continue with the process below.
The first screen after executing the utility will be as shown below:-
PAGE 31 of
36
User Manual Issue 1.2a
YED Avionics Ltd
DATAIR-400/M3 ARINC 429 TESTER
Select an available COM Port. Leave all other settings as they are above. Click <Next> to continue.
The next screen will then be presented:-
Press <Next> to continue.
Once again, leave the settings as they are presented and click <Next>
Issue 1.2a User Manual 32 of 36
YED Avionics Ltd
DATAIR-400/M3 ARINC 429 TESTER
Click the “Download to Device” option and browse to the location of the file to be used to reprogram the processor and select the upgrade file to program. In our example this is shown above as “NMEAtoArinc429-V12.bin”. Click <Open> to load the file.
Click <Next> to program the new firmware.
PAGE 33 of
36
User Manual Issue 1.2a
YED Avionics Ltd
DATAIR-400/M3 ARINC 429 TESTER
During programming the following screen will be shown:-
After successful programming the final screen below will be presented:-
Click <Close> to exit the utility and remove the cable. Your DATAIR-400/M3 firmware has now been updated.
Issue 1.2a User Manual 34 of 36
YED Avionics Ltd
DATAIR-400/M3 ARINC 429 TESTER
DECLARATION OF CONFORMITY
Manufacturer's Name:
Manufacturer's Address:
Declares, that the product(s):
Product Name:
Model Numbers(s):
YED Avionics Ltd
Park House
10 Park Street
Bristol
Avon BS1 5HX
UK
DATAIR-400/M3 ARINC 429 Monitor
DATAIR-400/M3
Product Options: All
Conforms to the following Product Specifications:
EMC: EN 61326: EMC requirements for Class A electrical equipment for measurement, control and laboratory use.
IEC 61000-4-2: Electrostatic discharge immunity.
IEC 61000-4-3: RF electromagnetic field immunity.
IEC 61000-4-4: Electrical fast transient / burst immunity.
Supplementary Information:
Emissions which exceed the levels required by this standard may occur when this equipment is connected to a test object.
Tested on: 12th November 2014
Result: The equipment fully complied with the requirements of the specified tests.
12th November 2014.
George Brownett,
Managing Director
,
For and on behalf of YED Avionics Limited
PAGE 35 of
36
User Manual Issue 1.2a
YED Avionics Ltd
FCC Regulations
DATAIR-400/M3 ARINC 429 TESTER
This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to Part 15 of the
FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Re-orient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by Yeovil
Electronic Developments could void the user's authority to operate this equipment.
Issue 1.2a User Manual 36 of 36
advertisement
Key Features
- Handheld ARINC 429 Tester
- Backlit LCD
- Alphanumeric keypad
- ARINC 429 receiver
- Transmitter board
- Detachable rechargeable battery pack
- User definable and customised ARINC 429 label definitions
- Data display in Hexadecimal, binary and Engineering Units
- Independent user configuration profiles for Tx operations
- Data entry in binary or Engineering Units
Frequently Answers and Questions
What is the purpose of the DATAIR-400/M3 ARINC 429 Tester?
Does the DATAIR-400/M3 support different data rates?
Can I define my own custom labels for the DATAIR-400/M3?
How long does the battery last on the DATAIR-400/M3?
What type of display does the DATAIR-400/M3 have?
Related manuals
advertisement
Table of contents
- 5 INTRODUCTION
- 8 OPERATION
- 9 MENU STRUCTURE
- 11 Notes
- 12 Receive Monitor & Engineering units screen
- 12 Notes
- 13 CLEAR ALL TX LABELS
- 14 SELECT ALL TX LABELS
- 14 ERROR: Too many labels enabled
- 15 SELECT LABELS TO TX and Label rates
- 15 SET GLOBAL TX RATE
- 17 SHOW / EDIT TX VALUES
- 19 Entering values for BCD formatted words
- 19 Entering values for BNR formatted words
- 19 Entering values for BNR “Special” formatted words
- 20 MODE: Setting the Transmitter mode
- 21 TX IS: Starting / Stopping the Transmitter
- 22 DATABASE
- 23 PROFILES
- 26 VIEW / EDIT LABEL
- 27 SUSPEND CUSTOM LABEL
- 29 DELETE CUSTOM LABEL
- 31 PERFORMING A FIRMWARE UPDATE
- 36 FCC REGULATIONS