SunTech Vet20 User manual
SunTech Vet20 is a veterinary-specific BP monitor that provides fast, accurate readings for cats and dogs. It has a large digital display, stores up to 99 measurements, and features clinical alarms, speaker control, and adjustable power management settings.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
Vet
20
BP MONITOR
Automated Blood Pressure Monitor for Veterinary Use
USER MANUAL
ii
Changes
This manual is identified as Part number: 80-0066-00 Rev. A. An updated version may be available for download from the
SunTech Medical website. Should you notice errors or omissions in this manual, please notify us at:
SunTech Medical, Inc.
507 Airport Boulevard, Suite 117
Morrisville, NC 27560 USA
Tel: 800.421.8626
919.654.2300
Fax: 919.654.2301
Email: [email protected]
Web: www.SunTechMed.com
Copyright Information
All content in this manual is the proprietary information of SunTech Medical and is provided solely for purposes of operation, maintenance or service of the SunTech Vet20. This manual and the SunTech Vet20 described in it are protected under copyright law under which they may not be copied, in whole or in part, without written consent of SunTech Medical.
The information in this manual is furnished for guidance only, is subject to change without notice, and should not be construed as a commitment by SunTech Medical. SunTech Medical assumes no liability for errors or inaccuracies that may appear in this manual.
© 2015 SunTech Medical. All rights reserved.
Welcome to the SunTech Vet20!
Thank you for choosing this SunTech Vet20 blood pressure monitor! For over 30 years, SunTech Medical has been the preeminent supplier of leading edge technology and innovative products to obtain blood pressure measurements. Developed specifically for the veterinary care environment, the SunTech Vet20 BP monitor quietly takes accurate blood pressure measurements very quickly and is extremely easy to use. The monitor also is lightweight and portable for convenient mobility between exam rooms and other clinic locations.
Table of Contents
Welcome to SunTech Vet20! ......................... iii
Safety Considerations .................................. iv
1. Warnings and Precautions ........................1
2. Icons and Symbols....................................4
3. Getting to know SunTech Vet20 ................5
4. Selecting Your Settings .............................8
5. Before You Begin ....................................12
6. Using SunTech Vet20 ..............................14
7. Taking Care of SunTech Vet 20 ...............17
Accessories & Replacement Parts .................. 18
Status Messages ......................................... 18
8. Frequently Asked Questions ...................20
9. Warranty ................................................21
10. Technical Information ...........................22
iii
iv
Safety Considerations
Intended Use
The SunTech Vet20 is intended to be used on companion animals, specifically dogs and cats, to obtain oscillometric blood pressure measurements, including systolic, diastolic and mean arterial pressure and heart beats per minute. This non-invasive monitor uses algorithms specifically designed for these animal populations.
User Responsibility
The SunTech Vet20 is designed to perform in conformity with the description thereof contained in this operation manual when operated. The user of this monitor shall have the sole responsibility for any malfunction which results from improper use, faulty maintenance, improper repair, damage or alteration by anyone other than SunTech Medical or their authorized service personnel.
1.
Warnings and
Precautions
A WARNING indicates a situation which, if not avoided, could result in serious injury or death.
WARNING: DO NOT connect patient hose or monitor to any other devices or connections, especially intravenous (IV) tubes as there is potential for air to be pumped into a blood vessel which could cause serious injury.
WARNING: Do not use in the presence of flammable anesthetics; this could cause an explosion. This device is not suitable for use in an oxygen enriched environment.
A CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user, patient or damage to the equipment or other property.
CAUTION: This monitor is for veterinary use only. NOT for use on humans.
CAUTION: DO NOT use the monitor for any purpose other than specified in this manual without written consent and approval from SunTech Medical. Substitution of a component or accessory different from that supplied may result in measurement error. Repairs should be undertaken only by personnel trained or authorized by SunTech Medical.
CAUTION: DO NOT use this monitor when oscillometric pulses may be altered by other devices or techniques.
1
2
CAUTION: DO NOT immerse the monitor in any fluid, place fluids on top of or attempt to clean with liquid detergents or cleaning agents. This may cause an electrical hazard. Do not use the monitor if accidental wetting occurs.
CAUTION: DO NOT remove unit covers. Doing so may increase the risk of electrical shock. This monitor does not contain any user serviceable parts.
CAUTION: DO NOT gas sterilize or autoclave this monitor.
CAUTION: Too frequent measurements may cause injury to the patient due to blood flow interference.
CAUTION: At the end of product life, the monitor, accessories, and other consumable goods may become contaminated from normal use. Consult local codes and ordinances for proper disposal of equipment and other consumable goods.
CAUTION: The monitor may not operate correctly if used or stored outside the relevant temperature or humidity ranges described in the Performance Specifications.
CAUTION: Do not use if device is dropped and/or is damaged. Have a qualified service representative check the unit before using again. Repairs should only be conducted by an authorized SunTech Medical service representative.
CAUTION: Remove batteries when device is not in use for long periods of time to prevent possible battery leakage and product damage.
A TIP provides application tips or other useful information to assure that you get the most from your equipment.
TIP:
This device is designed to be used on dogs and cats. In this document where the word “patient” is used, this is to mean a small animal such as a cat, dog, or other small animal.
TIP:
Accuracy of any blood pressure measurement may be affected by the position of the subject, the patient’s physical condition and use outside of the operating instructions detailed in this manual. Interpretation of blood pressure
measurements should be made only by a veterinarian or trained medical staff. Minimize limb movement during the measurement.
TIP:
To obtain accurate blood pressure readings, the cuff must be the correct size, and also be correctly fitted to the patient. Incorrect size or incorrect fitting may result in incorrect readings.
TIP:
ENSURE batteries are inserted with the correct polarity. Improper installation may cause equipment damage or malfunction. Follow battery installation procedures.
3
4
2.
Icons and
Symbols
Exits or closes a screen
Goes back to previous screen
TIP:
Provides practical advice for using monitor
Manual consultation symbol
This product meets the requirements of the applicable EMC Directive
Disposal in compliance with WEEE
Manufacturer
Date of Manufacture
Serial Number
Type BF applied part
Cuff index line must fall within range markings
Arrow should be placed over artery
Symbol indicating limb circumference
Index line
Not made with natural latex
3.
Getting to know
SunTech Vet20
Install Batteries and Connect Hose
Open battery door on monitor back and insert 4 AA batteries paying attention to the correct polarity. Use lithium ion or alkaline batteries. Do not use rechargeable batteries.
Connect the patient hose to the back of the monitor making sure the connector “clicks” into the locking position.
5
6
Front Panel
Power button.
Turns monitor on and off.
Start/Stop button.
Starts blood pressure measurement. Stops measurement at any time.
Colors: Magenta – monitor is ready to take a BP measurement
Blue – Measurement is in progress
Red – A problem occurred during the measurement
Main Screen View
After you begin using your SunTech Vet20, your main screen will display your most recent patient measurements. Here is a quick overview of the key symbols and numeric values you will see.
Battery life indicator
Measurement Number/
Size of Animal Measured
Blood Pressure Reading
Left arrow button/
View previous BP reading
Mean arterial pressure
Settings control
Animal selection
Right arrow button/
View next BP reading
Speaker control
Access memory/
Previous measurements
Heart beats per minute
7
8
4.
Selecting Your
Settings
Animal Selection Screen
When you turn on your SunTech Vet20, you will see the Animal Selection Screen. Even if you are not ready to measure BP on a patient, select either Large or Small animal so that you can proceed to the Main Screen. This screen can be turned off (see
Animal Selection). Additionally, the animal mode can be toggled using the animal selection icon on the Main screen.
Choosing the Correct Companion Animal Mode
Small Animal Mode should be chosen when taking BP measurements on all cats and small dogs up to a #3 BP cuff size. Large
Animal Mode has been designed for dogs requiring a #4 BP cuff or larger. This size typically applies to dogs weighing more than
8 kg (~17.5 lbs.). If a problem arises try switching animal modes.
Speaker Setting/Noise Control
The SunTech Vet20 monitor’s default setting is Speaker Off so that patients are not disturbed by sounds. To toggle between Speaker
Off and Speaker On, press the Speaker button. When sound is OFF, you still will hear a very quiet clicking when you touch buttons but no beeps.
Settings
9
Clinical Alarms.
Provides access to turning ON and setting clinical alarms.
Animal Selection.
Turn ON or OFF startup screen.
Power Management.
Select how long monitor stays on before Auto OFF shutdown.
Language.
Additional languages currently not available.
Clinical Alarms
The SunTech Vet20 allows clinical alarms for all BP values (SYS, DIA, MAP and HR). Factory setting is OFF.
10
• To change alarm values, touch Set Alarm Values.
• Touch the range value that you want to adjust.
• Using the keypad, type in the desired value and touch the checkmark.
• To reset to default clinical alarms, touch Use Defaults.
• Out of range values will be Red on the Main Screen. If speaker is ON, a beep will occur.
Power Management
The SunTech Vet20 includes an auto OFF feature which turns the monitor off after a selected time period.
Factory setting is 1 minute.
• Intervals include 1, 2 and 5 minutes as well as always
ON.
TIP: Batteries may be rapidly depleted if set to always ON.
Animal Selection
The animal selection start up screen can be turned OFF. This is useful for clinics catering to a specific breed such as an all cat clinic.
11
12
5.
Before You Begin:
Important Preparations
These preparations can help ensure a successful and accurate blood pressure measurement.
Where to Apply the Cuff
SunTech recommends that the cuff be placed on a front limb while the patient is lying on the right or left side. This helps ensure that the cuff is at heart level, which is best for measurement accuracy. Also, the patient is less likely to retract the front limb when the cuff gently squeezes it during the measurement. The cuff should be placed so that its artery marker aligns with the limb artery.
Alternate Patient Positioning: If the patient seems more comfortable seated, position the cuff as described above and hold up the limb during the BP measurement. This will help keep the cuff at heart level and relax the patient’s muscles. If the patient appears agitated enough to bite or scratch, or is standing, the base of the tail is an acceptable alternate location.
Cuff Size
The SunTech Vet20 comes with a variety of different BP cuff sizes. Each cuff contains important markings that help with selecting the right cuff size.
Make sure this part of cuff is placed over the patient’s artery.
When the cuff is wrapped around the patient’s limb, its Index Marker should fall within this line.
When you wrap the cuff around the patient’s limb, the Index Marker should fall within the Range Marker on the inside of the cuff.
Indicates limb circumference range of the cuff.
Not made with natural latex.
TIP: When more than one cuff size fits the limb, always choose the larger size for more accurate measurements. When a cuff is too small, it can cause BP values to be overestimated.
An alternative sizing method is to measure the circumference of the limb and choose a cuff whose width is 40% of the circumference for dogs and 30% for cats.
13
14
6.
Using SunTech
Vet20
Taking a BP Measurement
Step 1. Place blood pressure cuff on patient and connect hoses.
Position patient so that they are lying down. Place the cuff just above the paw making sure not to place it over a joint. Connect cuff hose to monitor hose. (See “Before You Begin” for cuff size/placement guidelines and alternate positioning options.)
TIP: The success of the BP measurement is dependent on choosing the correct cuff and attaching it to the patient correctly.
The cuff is the sensor so make sure to snugly fit the cuff as this provides better signals to the monitor.
Step 2. Power up and select animal mode.
Press the Power Button. Select Large or Small companion animal.
TIP: To change animal size after initial selection, touch the Animal Selection icon on Main Screen to toggle between Large and Small.
Step 3. Take blood pressure reading.
Press START/STOP button to start blood pressure measurement. START/STOP button turns Blue during measurement. Reading is complete when START/STOP button returns to Magenta. Main Screen will show SYS and DIA values, plus MAP and heart rate (BPM).
Interrupting/Stopping a Measurement
To stop a measurement while in progress, touch the START/STOP button. START/STOP button returns to Magenta and monitor is ready to start new reading.
Taking/Viewing Multiple Measurements
To take additional readings, press START/STOP again.
To view previous readings from the Main Screen, touch the
Left Arrow button on Main Screen.
Touch the right arrow to see more recent measurements and to return to the Main Screen.
Deletes all memory data
Averages values for selected data
Buttons disabled
To view previous readings from the Memory Screen, touch the Memory button on Main Screen.
Up to 50 measurements can be stored in memory.
15
16
Averaging Measurements
To average measurements, touch the rows with the measurements you wish to average. Selected rows will turn green. To unselect a measurement, touch its row a second time.
Average of selected readings shows on top row with “A” as the identifier.
7.
Taking Care of the
SunTech Vet20
Cleaning the Monitor
CAUTION: The SunTech Vet20 is not sterilizable. Do not immerse the monitor in any fluid or attempt to clean with any liquid detergents, cleaning agents, or solvents.
Dampen a soft cloth with mild medical grade disinfectant and wipe the monitor to remove surface dust and dirt.
Preventative Maintenance
System Self Checks
The SunTech Vet20 performs a range of system checks during normal operation. If the monitor detects a problem, it will display an error message recommending a trouble-shooting action or to contact SunTech Customer Service.
Replaceable Parts
On a routine basis, inspect the monitor, cuffs and hoses for cracks, fraying, or kinks. Immediately replace any damaged part.
17
18
Accessories & Replacement Parts
Contact your sales representative to purchase the following items:
Description Part Number Details
#1 Cuff 98-0400-80 3 – 6 cm, white, non-locking
#2 Cuff
#3 Cuff
#4 Cuff
#5 Cuff
98-0400-81
98-0400-82
98-0400-83
98-0400-84
#6 Cuff
#7 Cuff
98-0400-F1
98-0400-F3
Patient Hose 98-0028-72
4 – 8 cm, white, non-locking
6 – 11 cm, white, non-locking
7 – 13 cm, white, non-locking
8 – 15 cm, white, non-locking
12 – 19 cm, white, non-locking
17 – 25 cm, white, non-locking
4 ft (1.2m), black
Status Messages
If the SunTech Vet20 has a problem taking a blood pressure measurement, a short beep will occur (if speakers are ON), the
START/STOP button will turn Red and a Status Message will appear on the monitor screen. Take action as directed on the screen, or as suggested in the table below.
Status Message Reason
Air Leak There is a leak in the cuff, hose or monitor. Also possible if cuff or hose is not attached to the monitor.
Solution
•
Check that the hose is connected to the monitor and cuff.
•
Check that the cuff is properly tightened.
•
Check that the cuff is in the correct position.
•
Check that the cuff is not leaking air.
•
Check that the hose connections are not damaged or loose.
Status Message Reason
Value out of
Range
The blood pressure value is outside of SunTech Vet20’s published ranges.
Poor Signal
Quality
Monitor is not receiving a strong signal from patient. Also possible if a rapid deflation occurs during a measurement.
Artifact Detected Monitor is picking up on unexpected noise or movements.
Monitor Not
Ready
System Failure
Solution
•
Make sure you are using the proper cuff size.
•
Patient may have been moving too much.
•
Check that the cuff is properly tightened and in proper position.
•
Check that cuff is in correct position.
•
Check the patient.
•
Check that cuff is properly tightened.
•
Check that correct size cuff is used.
•
Check animal mode. It might be on wrong setting.
•
Check patient for motion, trembling. Too much movement.
•
Check that cuff is in correct position.
•
Check that correct size cuff is used.
•
Check to ensure cuff is fitting snugly on patient and is positioned properly.
•
Check that cuff is in correct position.
•
Check patient for moving, trembling.
Measurement
Too Long
The monitor is not detecting strong and consistent signals from the patient for an extended time period.
Check Batteries!
Battery power is low.
Air Blockage
Cuff Overpressure
Air is not able to pass through the hose or cuff properly.
Pressure in the cuff briefly exceeded
300 mmHg due to patient movement, air blockage or using a cuff that is too small.
Monitor is preparing for next measurement or may need service.
A monitor system has failed.
•
See the battery life indicator on the Main Screen.
Replace batteries if needed.
•
Check that hose has no sharp bends and is not pinched.
•
Check that patient is not lying or stepping on cuff.
•
Check that cuff is in correct position.
•
Check that correct size cuff is being used.
•
Check that hose has no sharp bends and is not pinched.
•
Check that patient is not lying or stepping on cuff.
•
Ensure patient is not moving excessively.
•
Touch START/STOP to start a new measurement. For repeated errors,
calibration or service may be required.
•
Service is required.
19
20
8.
Frequently
Asked Questions
Frequently Asked Questions
How many measurements can I store in Memory?
You can store up to 50 measurements. The monitor has a revolving memory. When you take your 51st measurement, it will be listed as measurement #1.
How long will the batteries last?
250+ BP measurements can be expected from typical alkaline batteries. Lithium batteries will provide even more measurements. Battery life is very dependent on the touch screen display ON time. To maximize life, SunTech suggests setting the Auto OFF timer to 1 minute.
How do I delete BP data from memory?
Select the Memory button and touch the Delete button. Before the memory is cleared, you will be asked to confirm or cancel the deletion. When you clear the Memory, you delete all measurements.
For medium-sized dogs, which animal mode do I choose?
Use cuff size as the determination factor. If a #3 cuff or smaller is the best fit, choose small animal mode. If #4 or larger, choose large animal mode.
Can I use this monitor on awake and anesthetized animals?
Yes. The SunTech Vet20 can be be used on anesthetized animals as well as awake animals.
How do I keep the cuff from slipping down the limb or coming off?
Attach the cuff as tight as possible. Extra attention will be needed on species with dense or thick fur. If the cuff will not stay attached, check the Velcro for fur and remove if possible.
How do I choose the correct cuff size?
Wrap the cuff around the patient’s limb and make sure the index line falls within the range marker. If two different cuff sizes fit the patient, choose the larger size.
9.
Limited
Warranty
SunTech Medical, Inc. provides to the original purchaser the following limited warranty from date of invoice.
Monitors
Cuffs/Hoses
24 months
90 days
SunTech Medical, Inc. warrants each instrument to be free from defects in material and workmanship. Liability under this warranty covers servicing of the instrument when returned from the customer’s facility within the United States prepaid to the factory. SunTech Medical, Inc. will repair any component(s) or part(s) that it finds to be defective during the period of this limited warranty. Should a defect become apparent, the original purchaser should first notify SunTech Medical, Inc. of the suspected defect. The instrument should be carefully packaged and shipped prepaid to:
SunTech Medical, Inc.
Service Department
507 Airport Boulevard, Suite 117
Morrisville, NC 27560 USA
Tel: 800.421.8626
919.654.2300
Fax: 919.654.2301
SunTech Medical, Ltd.
Service Department
Oakfield Industrial Estate
Eynsham, Oxfordshire OX29 4TS UK
Tel:
Fax:
44 (0) 1865.884.234
44 (0) 1865.884.235
21
This limited warranty is void if the instrument has been damaged by accident, misuse, negligence, act of God or serviced by any person not authorized by SunTech Medical, Inc. It contains the entire obligation of SunTech Medical, Inc. and no other warranties expressed, implied or statutory are given. No representative or employee of SunTech Medical, Inc. is authorized to assume any further liability or grant any further warranties except as herein.
22
10.
Technical
Information
Factory Default Settings
Parameter Name
Clinical Alarms Status
Clinical Alarms – low SYS
Clinical Alarms – High SYS
Clinical Alarms – low DIA
Clinical Alarms – High DIA
Clinical Alarms – low MAP
Clinical Alarms – High MAP
Clinical Alarms – low HR
Clinical Alarms – High HR
Speaker Status
Auto OFF Timer
Language
Startup Animal Selection
Default Value
OFF
40 mmHg
265 mmHg
20 mmHg
200 mmHg
27 mmHg
222 mmHg
25 bpm
300 bpm
OFF
1 minute
English
ON
Performance Specifications
Method of Measurement: Oscillometric
Blood Pressure Range:
Pulse Rate Range:
Systolic: 40 – 265mmHg
MAP: 27 – 222mmHg
Diastolic: 20 – 200mmHg
25 to 300 BPM (Beats Per Minute)
Cuff Deflate Rate: Deflation step size varies with heart rate, cuff pressure and cuff volume
Initial Inflation Pressure: 180 mmHg (default)
Subsequent initial inflation: previous Systolic + 30 mmHg
Transducer Accuracy:
Transducer Calibration:
Operating Conditions:
Storage Conditions:
Altitude:
±3mmHg between 0 mmHg and 300 mmHg
Recommended bi-annually or if a calibration problem is suspected
0°C to 50°C, 15% to 95% non-condensing humidity
-20°C to 65°C, 15% to 90% non-condensing humidity
Measurement accuracy not affected by altitude
Power:
Dimensions:
Weight:
4 AA alkaline batteries.
6.25” x 5” x 5.25” (15.9cm x 12.7cm x 13.3cm)
1.3 lbs (0.59Kg) with batteries
23
24
Electromagnetic Compatibility (EMC)
Guidance and manufacturer’s declaration – electromagnetic emissions
The Vet20 is intended for use in the electromagnetic environment specified below.
The customer or the user of the Vet20 should assure that it is used in such an environment.
Emissions test
RF emissions
CISPR 11
RF emissions
CISPR 11
Harmonic emissions
IEC 61000-3-3
Voltage fluctuations/ flicker emissions
Compliance Electromagnetic environment – guidance
Group1 The Vet20 uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment
Class B
Not applicable
The Vet20 is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply networks that supplies buildings used for domestic purposes.
Not applicable
Guidance and manufacturer’s declaration – electromagnetic immunity
The Vet20 is intended for use in the electromagnetic environment specified below. The customer or user of the Vet20 should assure that it is used in such an environment.
Immunity test IEC 60601test level Compliance level
Electromagnetic environment - guidance
Electrostatic discharge (ESD)
IEC 61000-4-2
Electrical fast transient/burst
IEC 61000-4-4
Surge
IEC 61000-4-5
Voltage dips, short interruptions and voltage variations on power supply input lines
IEC 61000-
4-11
Power frequency
(50/60 Hz)
Magnetic field
IEC 61000-4-8
± 6 kV contact
± 8 kV air
± 2 kV for power supply lines
± 1 kV for input/output lines
± 1 kV line(s) to line(s)
± 2 kV line(s) to earth
<5% UT (>95%dip in UT for 0.5 cycle
40% UT (60% dip in UT ) for 5 cycles
70% (30% dip in UT) for
25 cycles.
<5% (>95% dip in UT) for 5 s
3 A/m
± 6 kV contact
± 8 kV air
Not applicable
Not applicable
Not applicable
3 A/m
Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30%
Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment.
NOTE UT is the a.c. mains voltage prior to application of the test level
25
26
Guidance and manufacturer’s declaration – electromagnetic immunity
The Vet20 is intended for use in the electromagnetic environment specified below. The customer or user of the SunTech Vet20 should assure that it is used in such an environment.
Immunity test IEC 60601 test level
Compliance level Electromagnetic environment - guidance
Portable and mobile RF communications equipment should be used no closer to any part of the Vet20, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.
Conducted RF
IEC 61000-4-6
3 V rms 3 V rms
Recommended separation distance d = 1.2√P d = 1.2√P 80 MHz to 800 MHz
Radiated RF
IEC 61000-4-3
3 V/m 3 V/m d = 2.3√P 800 MHz to 2,5 GHz where P is the maximum output power rating of the transmitter in watts
(W) according to the transmitter manufacture and d is the recommended separation distance in metres (m). Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey, a
should be less than the compliance level in each frequency range b
Interference may occur in the vicinity of equipment marked with the following symbol:
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
a
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the Vet20 is used exceeds the applicable RF compliance level above, the Vet20 should be observed to verify normal operation. If b abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the Vet20.
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
Recommended separation distances between portable and mobile RF communications equipment and the Vet20
The Vet20 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the Vet20 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and Vet20 as recommended below, according to the maximum output power of the communications equipment.
Rated maximum output power of transmitter
Separation distance according to frequency of transmitter m
W
0.01
150 kHz to 80 MHz d=1.2√P
0,12
80 MHz to 800 MHz d=1.2√P
0,12
800 MHz to 2,5 GHz d=2.3√P
0,23
0.1
1
10
100
0,38
1,2
3,8
12
0,38
1,2
3,8
12
0,73
2,3
7,3
23
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
27
SunTech Medical, Inc.
507 Airport Boulevard, Suite 117
Morrisville, NC 27560-8200 USA
Tel: + 1.919.654.2300
1.800.421.8626
Fax:+ 1.919.654.2301
SunTech Medical, Ltd.
Oakfield Industrial Estate
Stanton Harcourt Road
Eynsham, Oxfordshire OX29 4TS
England
Tel: + 44 (0) 1865.884.234
Fax:+ 44 (0) 1865.884.235
SunTech Medical, Ltd.
2/F of Building A, Jinxiongda Technology Park
Guanlan, Bao’an District Shenzhen, 518110, PRC
Tel: + 86-755-2958 8810
+ 86-755-29588986 (Sales)
+ 86-755-29588665 (Service)
Fax:+ 86-755-2958 8829
80-0066-00-MA-RevA www.SunTechMed.com
www.SunTechMed.com www.CN.SunTechMed.com
advertisement
Related manuals
advertisement
Table of contents
- 5 1. Warnings and Precautions
- 8 2. Icons and Symbols
- 9 3. Getting to know SunTech Vet
- 12 4. Selecting Your Settings
- 16 5. Before You Begin
- 18 6. Using SunTech Vet
- 21 7. Taking Care of SunTech Vet
- 22 Accessories & Replacement Parts
- 22 Status Messages
- 24 8. Frequently Asked Questions
- 25 9. Warranty
- 26 10. Technical Information