Ingersoll Rand’s Climate Solutions sector delivers energy-effi cient HVACR solutions for customers globally. Its world class brands include Thermo King, the leader in transport temperature control and Trane, a provider of energy effi cient heating, ventilating and air conditioning systems, building and contracting services, parts support and advanced controls for commercial buildings and homes.
©2013 Ingersoll-Rand Company
Printed in U.S.A.
Ingersoll Rand’s Climate Solutions sector delivers energy-effi cient HVACR solutions for customers globally. Its world class brands include Thermo King, the leader in transport temperature control and Trane, a provider of energy effi cient heating, ventilating and air conditioning systems, building and contracting services, parts support and advanced controls for commercial buildings and homes.
©2013 Ingersoll-Rand Company
Printed in U.S.A.
Operator’s Manual
T-680R / T-880R / T-1080R
T-680S / T-880S / T-1080S
Series with
Premium SR-3 HMI
TK 55667-1-OP (Rev. 2, 09/16)
Operator’s Manual
T-680R / T-880R / T-1080R
T-680S / T-880S / T-1080S
Series with
Premium SR-3 HMI
TK 55667-1-OP (Rev. 2, 09/16)
T-680R / T-880R / T-1080R
T-680S / T-880S / T-1080S
Series with
Premium SR-3 HMI
TK 55667-1-OP (Rev. 2, 09/16)
Copyright© 2013 Thermo King Corp., Minneapolis, MN, USA
Printed in USA
2
Disclaimer
This manual is published for informational purposes only. Thermo King Corporation makes no representations or warranties, express or implied, with respect to the information, recommendations and descriptions contained in this manual and such information, recommendations and descriptions should not be regarded as all-inclusive or covering all contingencies. In the event you have any questions or require further information, please contact your local Thermo King dealer.
The procedures described herein should only be undertaken by suitably qualified personnel. Failure to implement these procedures correctly may cause damage to the Thermo King unit or other property or personal injury.
Thermo King Corporation and its affiliates shall have no liability in contract or tort (including negligence and/or strict liability) or otherwise, to any person or entity for any personal injury, property damage or any other direct, indirect, special or consequential damage or liability whatsoever, arising out of or resulting from any actions by any person that are contrary to this manual or any of the information, recommendations or descriptions contained herein or the failure of any person to implement the procedures described herein correctly or to follow caution and safety decals located on the Thermo
King unit.
Table of Contents
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Automatic Start/Stop Operation . . . . . . . . . . . . . . . . . . 8
Battery Installation and Cable Routing . . . . . . . . . . . . . 9
Electrical Hazard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Refrigerant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Refrigerant Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
First Aid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
First Aid–Refrigerant . . . . . . . . . . . . . . . . . . . . . . . 11
First Aid–Refrigerant Oil . . . . . . . . . . . . . . . . . . . . 11
Safety Decals and Locations . . . . . . . . . . . . . . . . . . . 11
Model 50 Units (Electric Standby) . . . . . . . . . . . . 14
Emission Control . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
California Emission Control System Warranty
Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Your Warranty Rights And Obligations . . . . . . . . . 18
Manufacturer’s Warranty Coverage . . . . . . . . . . .19
Owner’s Warranty Responsibilities . . . . . . . . . . . .19
Manufacturer Explanation Of Emission Control System
Warranty Coverage . . . . . . . . . . . . . . . . . . . . . . . . . . .20
EPA Emission Control System Warranty Statement . .22
Responsibilities . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Thermo King Corporation Responsibilities . . . . . . . . . .23
Owner Responsibilities . . . . . . . . . . . . . . . . . . . . . . . .23
Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Unit Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
General Description . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Design Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Unit Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
ELC (Extended Life Coolant) . . . . . . . . . . . . . . . . . . . .28
Clutch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Reciprocating Compressor . . . . . . . . . . . . . . . . . . . . .29
Scroll Compressor . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Premium HMI Control Panel . . . . . . . . . . . . . . . . . . . .29
3
Table of Contents
CYCLE-SENTRY™ Start/Stop System . . . . . . . . . . . . 30
Defrost . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
DAS - Data Acquisition System (Optional) . . . . . . . . . 31
CargoLink™ (Optional) . . . . . . . . . . . . . . . . . . . . . . . . 31
Electric Standby (Model 50 Units Only) . . . . . . . . . . . . 31
Standard Model 50 Features . . . . . . . . . . . . . . . . 32
Optional Model 50 Features . . . . . . . . . . . . . . . . . 32
Engine Compartment Components . . . . . . . . . . . . . . . 32
Unit Protection Devices . . . . . . . . . . . . . . . . . . . . . . . . 33
Unit Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Premium HMI Control Panel . . . . . . . . . . . . . . . . . 37
Controller Features . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Hard Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Soft Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Typical soft key functions: . . . . . . . . . . . . . . . . . . . . . . 40
Turning the Unit On and Off . . . . . . . . . . . . . . . . . . . . 41
If More Than One Language is Enabled . . . . . . . . 42
The Standard Display . . . . . . . . . . . . . . . . . . . . . . . . . 44
Changing the Setpoint . . . . . . . . . . . . . . . . . . . . . . . . . 45
Starting the Diesel Engine . . . . . . . . . . . . . . . . . . . . . . 47
Starting the Electric Motor . . . . . . . . . . . . . . . . . . . . . . 48
Switching from Diesel to Electric . . . . . . . . . . . . . . . . 49
Switching from Electric to Diesel . . . . . . . . . . . . . . . . 50
Initiating a Manual Defrost Cycle . . . . . . . . . . . . . . . . 51
Terminating a Defrost Cycle . . . . . . . . . . . . . . . . . . . . 52
Selecting High Speed Lockout Mode (If Enabled) . . . 52
Selecting CYCLE-SENTRY or Continuous Mode . . . 54
Using the Gauges Key . . . . . . . . . . . . . . . . . . . . . . . . 54
Gauges Available . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Using the Sensors Key . . . . . . . . . . . . . . . . . . . . . . . . 56
Sensors Available . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Using The Main Menu . . . . . . . . . . . . . . . . . . . . . . . . . 57
Main Menu Choices . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Languages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Alarm Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Log Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Check Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Shutdown Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Prevent Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Pretrip Alarm Codes . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Alarm Codes When Switching Between Diesel and
Electric . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Alarm Code Notification . . . . . . . . . . . . . . . . . . . . . . . 65
Clearing Alarm Codes . . . . . . . . . . . . . . . . . . . . . . . . 66
4
Table of Contents
Displaying and Clearing Alarm Codes . . . . . . . . . . . . 67
SR-3 Alarm Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Datalogger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Hourmeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Hourmeter Names and Definitions . . . . . . . . . . . . . . . 80
Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Turn CYCLE-SENTRY On or Off . . . . . . . . . . . . . . . . 81
Keypad Lockout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Start Sleep Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Selecting CYCLE-SENTRY or Continuous Mode . . . . 83
Selecting Sleep Mode . . . . . . . . . . . . . . . . . . . . . . . . . 85
Pretrip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Pretrip Test Conditions . . . . . . . . . . . . . . . . . . . . . . . . 89
Conditions where Pretrip Tests are not allowed . . . . . 89
Pretrip Test Sequence . . . . . . . . . . . . . . . . . . . . . . . . 90
Pretrip Test Considerations . . . . . . . . . . . . . . . . . . . . 90
Performing a Pretrip Test . . . . . . . . . . . . . . . . . . . . . . 91
Diesel/Electric Menu . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Switching from Diesel to Electric - Units equipped with the
Electric Standby option only. . . . . . . . . . . . . . . . . . . . 93
Switching from Electric to Diesel - Units equipped with the
Electric Standby option only . . . . . . . . . . . . . . . . . . . . 94
Adjust Brightness . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Loading and Enroute Inspections . . . . . . . . . . . . . .98
Pre-Loading Inspection . . . . . . . . . . . . . . . . . . . . . . . .98
Inspecting the Load . . . . . . . . . . . . . . . . . . . . . . . . . . .99
Enroute Inspections . . . . . . . . . . . . . . . . . . . . . . . . . .100
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .102
Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .102
Belt Tension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .105
Engine Clutch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .106
Reciprocating Compressor . . . . . . . . . . . . . . . . .106
Scroll Compressor . . . . . . . . . . . . . . . . . . . . . . . .107
Electrical Control System . . . . . . . . . . . . . . . . . . . . . .108
Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109
Electrical Components . . . . . . . . . . . . . . . . . . . . . . . .110
(Model 50 Units Only) . . . . . . . . . . . . . . . . . . . . . . . . .112
T-1080R & T-1080S Electric Motor and Overload
Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112
Electric Heater Strips (Optional) . . . . . . . . . . . . . . . .113
SmartPower Standby Power Requirements . . . . . . .113
5
Table of Contents
Maintenance Inspection Schedule . . . . . . . . . . . . . 114
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
Serial Number and Refrigerant Label Locations . 121
Recover Refrigerant . . . . . . . . . . . . . . . . . . . . . . . . 124
Emergency Cold Line . . . . . . . . . . . . . . . . . . . . . . . 125
Proposition 65 Warning . . . . . . . . . . . . . . . . . . . . . 126
6
Introduction
There is nothing complicated about operating and maintaining your Thermo King unit, but a few minutes studying this manual will be time well spent.
Performing pre-trip checks and enroute inspections on a regular basis will minimize on-the-road operating problems. A regular maintenance program will also help to keep your unit in top operating condition. If factory recommended procedures are followed, you will find that you have purchased the most efficient and dependable temperature control system available.
All service requirements, major and minor, should be handled by a Thermo King dealer for four very important reasons:
• They are equipped with the factory recommended tools to perform all service functions
• They have factory trained and certified technicians
• They have genuine Thermo King replacement parts
• The warranty on your new unit is valid only when the repair and replacement of component parts is performed by an authorized Thermo King dealer.
IMPORTANT: This manual is published for informational purposes only and the information furnished herein should not be considered as all-inclusive or meant to cover all contingencies. If more information is required, consult your
Thermo King Service Directory for the location and telephone number of the local dealer.
7
8
Safety Precautions
Thermo King recommends that all services be performed by a
Thermo King dealer. However, there are several general safety practices which you should be aware of:
WARNING: Always wear goggles or safety glasses when working with or around the refrigeration system or battery. Refrigerant or battery acid can cause permanent damage if it comes in contact with your eyes.
WARNING: Keep hands and loose clothing clear of fans and belts at all times when the unit is operating or when opening or closing compressor service valves.
WARNING: Exposed coil fins can cause painful lacerations. Service work on the evaporator or condenser coils is best left to a certified Thermo King technician.
CAUTION: Use extreme caution when drilling holes in the unit. Drilling into electrical wiring or refrigerant lines could cause a fire. Never drill into structural components.
Automatic Start/Stop Operation
This unit is capable of automatic operation and may start at any time without prior warning.
WARNING: The unit may start at any time when the controller is turned on. The controller display lights up when the controller is turned on.
WARNING: Units equipped with electric standby may start at any time when the unit is connected to live electric power and the controller is turned on.
WARNING: Be sure to press the OFF key to turn the controller off before opening doors or inspecting any part of the unit.
Battery Installation and Cable
Routing
WARNING: Improperly installed battery could result in a fire or explosion! A Thermo King approved battery must be installed and properly secured to the battery tray.
WARNING: Improperly installed battery cables could result in fire or explosion! Battery cables must be installed, routed and secured properly to prevent them from rubbing, chaffing or making contact with hot, sharp or rotating components.
WARNING: Do not attach fuel lines or any additional wiring harnesses to the battery cables as this could cause an electrical fire!
CAUTION: Do not connect other manufacturer’s equipment or accessories to the Thermo King unit.
This could result in severe damage to equipment and void the warranty!
Safety Precautions
CAUTION: Set all unit electrical controls to the
OFF position before connecting battery cables to the battery to prevent unit from starting unexpectedly and causing personal injury.
CAUTION: Always wear protective clothing, gloves and eye wear when handling and installing batteries. Battery acid can cause serious burns when exposed to eyes or skin. If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters your eye, immediately flood it with running cold water for at least twenty minutes and get medical attention immediately.
CAUTION: Always cover battery terminals to prevent them from making contact with metal components during battery installation. Battery terminals grounding against metal could cause the battery to explode.
9
Safety Precautions
Electrical Hazard
CAUTION: Be sure to turn off the high voltage power supply, and disconnect the electric cable before working on the unit. Units with electric standby present a potential electrical hazard.
Refrigerant
Although fluorocarbon refrigerants are classified as safe, observe caution when working with refrigerants or around areas where they are being used in the servicing of your unit.
DANGER: Fluorocarbon refrigerants may produce toxic gases. In the presence of an open flame or electrical short, these gases are severe respiratory irritants CAPABLE OF CAUSING DEATH.
DANGER: Fluorocarbon refrigerants tend to displace air and can cause oxygen depletion which could result in DEATH BY SUFFOCATION. Provide adequate ventilation in enclosed or confined areas.
WARNING: Fluorocarbon refrigerants evaporate rapidly, freezing anything they contact if accidentally released into the atmosphere from the liquid state.
Refrigerant Oil
Observe the following precautions when working with or around refrigerant oil:
WARNING: Always wear goggles or safety glasses to protect eyes from refrigerant oil contact.
WARNING: Protect skin and clothing from prolonged or repeated contact with refrigerant oil.
Rubber gloves are recommended.
WARNING: Wash thoroughly immediately after handling refrigerant oil to prevent irritation.
10
Safety Precautions
First Aid
First Aid–Refrigerant
Eyes: For contact with liquid, immediately flush eyes with large amounts of water. Get prompt medical attention.
Skin: Flush areas with large amounts of warm water. Do not apply heat. Wrap burns with dry, sterile, bulky dressing to protect from infection or injury. Get prompt medical attention.
Inhalation: Move victim to fresh air and restore breathing if necessary. Stay with victim until arrival of emergency medical personnel.
First Aid–Refrigerant Oil
Eyes: Immediately flush eyes with large amounts of water for at least 15 minutes while holding the eyelids open. Get prompt medical attention.
Skin: Remove contaminated clothing. Wash thoroughly with soap and water. Get medical attention if irritation persists.
Inhalation: Move victim to fresh air and restore breathing if necessary. Stay with victim until arrival of emergency personnel.
Ingestion: Do not induce vomiting. Immediately contact local poison control center or physician.
Safety Decals and Locations
Figure 1: Antifreeze Caution
(Attached near Expansion Tank fill cap)
11
Safety Precautions
12
Figure 2: Clearing Alarms Caution
(Typically located near the HMI Controller)
Figure 3: Belt Caution (Locations vary depending on model. Decals are located near areas that contain belts and fans which can cause severe injuries if hands or clothing become tangled.)
Safety Precautions
CAUTION FAN
ATTENTION VENTILATEUR
ACHTUNG VENTILATOR
ATTENZIONE VENTILATORE
CUIDADO VENTILADOR
Figure 4: Automatic Start Caution (Locations vary depending on model. Decals are located near areas that contain moving parts which can cause severe injuries if hands or clothing become tangled when the unit automatically starts.)
Figure 5: Fan Caution (Locations vary depending on model. Decals are located near areas that contain fans which can cause severe injuries if hands or clothing become tangled.)
13
Safety Precautions
Model 50 Units (Electric Standby)
Figure 6: Electrical Hazard (Locations vary depending on model. Typically located near power receptacle, high voltage tray cover and interface board.)
Figure 7: High Voltage Caution
(Located near high voltage box.)
14
Emission Control
In compliance with the California ULG (Utility, Lawn and
Garden) Rules, the following information is provided:
1. Selection Of Fuel Oil: Use diesel fuel only.
2-1. Modification To Any Engine Component:
Modifications to any engine component which many cause engine exhaust emission output changes are not allowed.
Any engine modification not in compliance with regulation will be the responsibility of the engine manufacturer, dealer or customer who made the modification.
2-2. Air Induction System: Air induction system must remain intact and receive regular prescribed maintenance.
Example: Air cleaner element replacement at required operation hour interval.
2-3. Exhaust System: Exhaust system must remain intact and cannot be modified in any manner that will further restrict exhaust flow.
2-4. Fuel Oil System: Fuel oil system must remain intact and receive regular prescribed maintenance. Example: Fuel filter replacement at required operation hour interval.
3. Engine Identification: Engines must be identified in a manner that will determine when they were built and what regulations they comply with. The engine must be labeled with an emission control label and the engine family name, both described below.
15
Emission Control a.
Emission control label: a new label, shown in
Figure 8, contains important engine information.
b.
Engine Family Name, as assigned by the California
Air Resources Board, identifies engine family group, by largest displacement, within an engine family, and
AMA04
Figure 8: Emission Control Label
16
AMA06
Figure 9: Engine Family Name
Emission Control
3-1 Emission Control Labels: Emission control labels are a requirement of the California ULG Rules. In the event the emission control label provided on the engine is inaccessible, there will be a supplemental label containing the same information, provided by the equipment manufacturer, located
in a readily accessible location, shown in Figure 10:
All engine labels and supplementary labels will contain the following information:
• Engine Family Name
• Displacement
• Manufacturer
The above information, along with the engine serial number, will be required to obtain proper service information and correct service repair parts. An example list which identifies
the exhaust control system is shown in Figure 11.
AMA05
Figure 10: Emission Control Label Location
1.
2.
Engine Model
3TNV70-TK
3TNV76-TK
Engine Family Name
6YDXL0.85W3N
6YDXL1.11W3N
Note: Design parameters to bring engine family into compliance were utilized; no after treatment measures incorporated.
Figure 11: Exhaust Control Systems
17
Emission Control
4. Emission Control Related Parts: The California ULG
Rules require a manufacturing defect warranty on all emission control parts, including:
• Fuel Injection Pump
• Fuel Injection Nozzle
• High Pressure Oil Line
• Air Cleaner Element
1
• Fuel Filter Element
1
• Air Cleaner Gasket
• Air Intake Pipe (Manifold) Gasket
• Muffler Gasket
The warranty period is two years and complete details are included in the section of this manual titled “California
Emission Control System Warranty Statement, Your Warranty
Rights And Obligations.”
1
Any warranted part which is scheduled for replacement as required maintenance shall be warranted for the period of time up to the first scheduled replacement point for that part.
5. Maintenance Schedule: To maintain optimum engine performance and compliance with the California ULG Rules, the maintenance schedule must be adhered to.
Regular scheduled maintenance is the major key to engine service life and emission regulation compliance. Scheduled maintenance requirements must be performed regularly. See the Maintenance Schedule provided in this Operator’s Manual.
California Emission Control
System Warranty Statement
Your Warranty Rights And
Obligations
The California Air Resources Board and Thermo King are pleased to explain the California emission control system warranty on your 1996 and later utility equipment (ULG) engine. In California, new utility equipment (ULG) engines must be designed, built, and equipped to meet the state’s stringent anti-smog standards. Thermo King must warrant the
California emission control system on your utility equipment
18
Emission Control
(ULG) engine for the time listed below, provided there has been no abuse, neglect or improper maintenance of your utility equipment (ULG) engine.
Your California emission control system includes parts such as the fuel injection pump, the fuel injection nozzle, and the high-pressure fuel line. Also included are the air filter element and the fuel filter element which are covered under this
California emission control system warranty only up to the first scheduled maintenance replacement.
Where a warrantable condition exists, Thermo King will repair your utility equipment (ULG) engine with California emission control system parts or components at no cost to you, including diagnosis, parts and labor.
Manufacturer’s Warranty Coverage
1996 and later utility equipment (ULG) engines: California emission control system parts and components are warranted for the period of two years (24 months). If any California emission control system part or component on your utility equipment (ULG) engine is defective, the part or component will be repaired or replaced by Thermo King.
Owner’s Warranty Responsibilities
As the utility equipment (ULG) engine owner, you are responsible for the performance of the required maintenance listed in this Operator’s Manual. Thermo King recommends that you retain all receipts covering maintenance on your utility equipment (ULG) engine, but Thermo King cannot deny warranty solely for the lack of receipts or your failure to ensure the performance of all scheduled maintenance.
As the utility equipment (ULG) engine owner, you should be aware that Thermo King may deny you warranty coverage if your utility equipment (ULG) engine, or a part or component, has failed due to abuse, neglect, improper maintenance, or unapproved modifications.
You are responsible for presenting your utility equipment
(ULG) engine to an authorized Thermo King dealer as soon as a problem exists. The emission control system parts or component repairs should be completed in a reasonable amount of time not to exceed 30 days.
If you have any questions regarding your warranty rights and responsibilities, contact a Thermo King service representative at 952-887-2337.
19
Emission Control
Manufacturer Explanation Of
Emission Control System
Warranty Coverage
A. Warranty Commencement Date
The California emission control system warranty period begins on the date the engine or equipment is delivered to the original retail purchaser.
B. Length Of Coverage
Thermo King warrants to the original purchaser, and each subsequent purchaser, that the engine emission control system is free from defects in material and workmanship that cause the failure of the warranted California emission control system part or component for a period of two years (24 months) beginning on the day the utility equipment (ULG) engine is delivered to the original purchaser.
C. What Is Covered
1.
Repair or Replacement of Parts: Repair or replacement of any California emission control system warranted part or component will be performed at no charge to the owner at a Thermo King authorized service dealer. To obtain the phone number of your nearest Thermo King authorized service dealer, call the Cold Line at: 952-887-2202.
2.
Warranty Period: Any warranted California emission control system part or component that is not scheduled for replacement as required maintenance, or that is scheduled only for regular inspection to the effect of repair or replacement as necessary, shall be warranted for the warranty period. Any warranted part that is scheduled for replacement as required maintenance shall be warranted for the period of time up to the first scheduled replacement point for that part or component.
3.
Diagnosis: The owner shall not be charged for diagnostic labor which leads to the determination that a California emission control system warranted part or component is defective, if the diagnostic work is performed at a Thermo
King authorized service dealer.
4.
Consequential Damages: Thermo King is liable for damages to other engine parts or components caused by the failure of an emission control system part or component within the above stated California emission control system warranty period.
20
Emission Control
D. What is Not Covered
1.
Failures caused by abuse, neglect, or improper maintenance.
2.
Add-On or Modified Parts. The use of add-on or modified parts can be grounds for disallowing a warranty claim.
Thermo King is not liable for failures of emission control system parts or components caused by the use of add-on or modified parts.
3.
Use of fuel other than the California Title 13, CCR Section
2282 (g)(3), low sulfur, low aromatic, with a cetane number of 48 minimum, will nullify this warranty.
E. How to File a Claim
Warranty claims for California emission control system parts or components are to be filed by the Thermo King authorized servicing dealer on behalf of the engine owner.
F.
Where to Get Warranty Service
Warranty service or repairs shall be provided at all Thermo
King authorized service dealers. You can generally find dealers in the Yellow Pages of your regional telephone directory, or call the customer service representative at 888-887-2202 for the location of the nearest Thermo King authorized service dealer.
G. Maintenance, Replacement and Repair of Emission
Control System Related Parts
Any Thermo King approved replacement part can be used in the performance of any warranty maintenance or repairs on emission control system parts or components, and must be provided without charge to the owner if the part is still under the California emission control system warranty.
H. Emission Control System Warranty Parts List
• Part Name
• Fuel Injection Pump
• Fuel injection Nozzle
• High Pressure Fuel Oil Line
• Air Cleaner Element
• Fuel Filter Element
• Air Cleaner Gasket
• Air Intake Pipe (Manifold)
• Gasket Muffler Gasket
I.
Maintenance Statements
The owner is responsible for the performance of the required maintenance as defined by Thermo King within this Operator’s
Manual.
21
Emission Control
EPA Emission Control System
Warranty Statement
Thermo King warrants to the initial owner and each subsequent owner that the certified non-road diesel engine in your unit is:
1.
Designed, built and equipped so as to conform, at the time of sale, with all applicable regulations adopted by the
United States Environmental Protection Agency (EPA).
2.
Free from defects in materials and workmanship in specific, emission-related parts for a period of five years or 3,000 hours of operation, whichever comes first, after date of delivery to the initial owner.
If an emission-related part or component fails during the warranty period, it will be repaired or replaced. Any such part or component repaired or replaced under warranty is warranted for the warranty period.
During the term of this warranty, Thermo King will provide, through a Thermo King authorized service dealer or other establishment authorized by Thermo King, repair or replacement of any warranted part at no charge to the non-road engine owner.
In an emergency, repairs can be performed at any service establishment, or by the owner, using any replacement part.
Thermo King will reimburse the owner for their expenses, including diagnostic charges, for such emergency repair. These expenses shall not exceed Thermo King’s suggested retail price for all warranted parts replaced, and labor changes based on
Thermo King’s recommended time allowance for the warranty repair and the geographically appropriate hourly labor rate.
Any replacement part can be used for maintenance or repairs.
The owner should ensure that such parts are equivalent in design and durability to genuine Thermo King parts. However,
Thermo King is not liable for parts which are not genuine
Thermo King parts.
A part not being available within 30 days or repair not being completed within 30 days constitutes an emergency.
As a condition of reimbursement, replaced parts and received invoices must be presented at a place of business of a Thermo
King authorized service dealer or other establishment authorized by Thermo King.
This warranty covers the following emission-related parts and components:
• Fuel Injection System
22
Emission Control
• Intake Manifold
• Exhaust Manifold
• Miscellaneous hoses, clamps, connectors and sealing devices used in the above systems.
If failure of one of these parts or components results in failure of another part or component, both will be covered by this warranty.
Responsibilities
This warranty is subject to the following:
Thermo King Corporation Responsibilities
During the emission warranty period, if a defect in material or workmanship of a warranted part or component is found,
Thermo King will provide:
• New, remanufactured, or repaired parts or components required to correct the defect.
NOTE: Items replaced under this warranty become the property of Thermo King.
• Labor, during normal working hours, required to make the warranty repair. This includes diagnosis and labor to remove and install the engine, if necessary.
Owner Responsibilities
During the emission warranty period, the owner is responsible for:
• The performance of all required maintenance. A warranty claim will not be denied because the scheduled maintenance was not performed. However, if the lack of required maintenance was the reason for the repair, then the claim will be denied.
• Premium of overtime cost.
• Cost to investigate complaints that are not caused by defect in Thermo King material or workmanship.
• Providing timely notice of a warrantable failure and promptly making the product available for repair.
Limitations
Thermo King is not responsible for resultant damages to an emission-related part or component resulting from:
• Any application or installation Thermo King deems improper as explained in this Operator’s Manual, or any other manuals provided with the unit.
23
Emission Control
• Attachments, accessory items, or parts not authorized for use by Thermo King.
• Improper off-road engine maintenance, repair, or abuse.
• Owner’s unreasonable delay in making the product available after being notified of a potential product problem.
This warranty is in addition to Thermo King’s standard warranty applicable to the off-road engine product involved.
Remedies under this warranty are limited to the provision of material and services as specified herein. Thermo King is not responsible for incidental or consequential damages such as downtime or loss of engine-powered equipment.
24
Unit Description
General Description
This manual covers the following Thermo King models:
• T-680R, T-880R and T-1080R with reciprocating compressor.
• T-680S, T-880S and T-1080S with scroll compressor.
All units are microprocessor based transport temperature control systems that use the Premium SR-3 Truck HMI microcontroller to manage system functions.
All units are one-piece, front-mounted, diesel powered cooling and heating systems designed for straight trucks. The unit mounts on the front of a truck with the evaporator portion protruding into the box. They are designed for use with chlorine free refrigerants.
Units are offered as Model 30 or Model 50:
Model 30: Cooling and hot gas heating on engine operation.
Model 50: Cooling and hot gas heating on engine operation and electric standby operation. Electric evaporator heaters are optional.
Engine power for the unit is provided by a diesel engine.
Optional SmartPower electric standby power is provided by an electric motor. A clutch on the diesel engine isolates the engine during electric standby operation.
The continuous monitoring function of the SR-3 microprocessor optimizes the unit’s performance, reducing fuel consumption and unit down time. The unit has a self check feature that can be run before the daily distribution route to identify possible malfunctions.
The built-in CYCLE-SENTRY, an exclusive Thermo King feature, automatically starts and stops the unit according to temperature demands.
25
Unit Description
Design Features
• Microprocessor Controller, SR-3 Truck
• Alarm Code Display
• Battery Voltage Display
• Continuous System Monitoring
• Coolant Temperature Display
• CYCLE-SENTRY ™ Start/Stop Controls
• Engine and Electric (Model 50) Hour Display
• In-Cab Remote
• Smart Defrost
• Symbolic Controller Interface
• Unit Self Check-pretrip
• Aerodynamic Thermo Plastic Recyclable Injection
Molded Skins with In-mold Color
• Air Cleaner, Dry Type
• Alternator, 12 Volt, 37 Amp
• Automatic Phase Correction (Model 50)
26
• Bypass Oil Filter
• Coolant Expansion Tank with Overflow Bottle
• Diesel/Electric Autoswitching (Model 50)
• Economy Mode
• Fahrenheit and Celsius Scales
• Fuel Filter, Spin On
• Low Decibel Kit
• Oil Filter, Full Flow
• Poly-V Belt System with Quiet Channel Technology
• R-404A Chlorine-free Refrigerant
• Robotic Welded Steel Frame with Automotive Grade 2
Coat Paint Finish
• X214 Compressor (T-680R and T-880R)
• X426 Compressor (T-1080R)
• TK04 Scroll 4 HP (T-680S and T-880S)
• TK06 Scroll 6 HP (T-1080S)
• ETV (Electronic Throttling Valve)
• Stainless Steel Condenser and Evaporator Hardware
• TK374F Tier 4 Diesel Engine (T-680R, T-680S, T-880R and T-880S)
• TK380F Tier 4 Diesel Engine (T-1080R and T-1080S)
Unit Options
• Body Mount HMI Enclosure Systems
• DAS (Data Acquisition System)
• Door Switch
• CargoLink™ Wireless Sensors
• Easy-Read Thermometer
• Electric Evaporator Heater
• SmartPower™ Electric Standby Operation (Model 50)
• Engine Block Heater
• Fuel Tank
• Hand-held SR-3 Electronic Diagnostic Tool
• Hose Management System
• Quick Oil Drain Kit
• Rear Remote Control (flushmount)
• Remote Indicator Light
• Snow Cover
• Telematics
• Whisper ™ Plus Sound Kit
• Top Cover System
Unit Description
27
Unit Description
Engine
Engine power for the T-680R, T-680S,T-880R and T-880S is provided by the TK374F, a three-cylinder, EPA Tier 4, special clean and quiet diesel engine rated at 11.7 continuous horsepower (8.7 kW) at 2200 RPM. A belt drive system transfers energy to the compressor, unit fans, and alternator.
Engine power for the T-1080R and T-1080S is provided by the
TK380F, a three cylinder, EPA Tier 4, special clean and quiet diesel engine rated at 16.2 continuous horsepower (12.1 kW) at
2200 RPM. A belt drive system transfers energy to the compressor, unit fans and alternator.
ELC (Extended Life Coolant)
The maintenance interval for ELC is five years or 12,000 hours. A nameplate on the coolant expansion tank identifies units with ELC (see “Safety Decals and Locations”). The new engine coolant, Texaco Extended Life Coolant, is Red instead of the previous Green or Blue-Green coolants.
ARB108
Figure 12: ELC (Extended Life Coolant) Nameplate
(Located near Expansion Tank in units equipped with
ELC)
CAUTION: Do not add Green or Blue-Green coolants to cooling systems that use Red Extended
Life Coolants.
28
Unit Description
NOTE: The use of 50/50% pre-mixed ELC is recommended to ensure that deionized water is being used. If 100% full strength concentrate is used, deionized or distilled water is recommended instead of tap water to ensure the integrity of the cooling system is maintained.
Clutch
The centrifugal clutch engages fully at 600 ± 100 RPM on engine operation, constantly turning the compressor, alternator, and fans at both high and low speed. The clutch isolates the engine from the belt drive system during electric standby operation on Model 50 units.
Reciprocating Compressor
The T-680R and T-880R feature the X214, 2 cylinder reciprocating compressor with 13.92 cu in (229 cc) displacement.
The T-1080R features the X426, 4-cylinder reciprocating compressor with 25.9 cu in (424 cc) displacement.
Scroll Compressor
The T-680S and T-880S feature the TK04 scroll compressor.
The T-1080S features the TK06 scroll compressor.
Premium HMI Control Panel
The Premium Truck HMI (Human/Machine Interface) Control
Panel is available as an option on SR-3 Truck applications. It is used to operate the unit, display unit information and access all
SR-3 Maintenance and Guarded Access Menus. The Control
Panel is typically located in the vehicle driver's compartment and communicates with the base controller using a connection on the interface board.
Figure 13: Premium HMI Control Panel
29
Unit Description
CYCLE-SENTRY
™
Start/Stop
System
The CYCLE-SENTRY Start/Stop fuel saving system provides optimum operating economy.
WARNING: Turn the unit off by pressing the OFF key before opening doors or inspecting any part of the unit. The unit can start at any time without warning if it has been turned on by pressing the ON key.
The CYCLE-SENTRY system automatically starts the unit on microprocessor demand and shuts down the unit when all demands are satisfied.
The system monitors and maintains the compartment temperature, the engine block temperature, and battery charge levels at a point where quick, easy starts are possible.
Defrost
Frost will gradually build up on the evaporator coils as a result of normal operation. Periodically this frost must be melted to prevent a loss of cooling and airflow.
Defrost is accomplished by passing hot refrigerant gas through the evaporator coil, thus melting the frost (or ice). Melted frost drains out of the unit onto the ground through the drain tubes.
The defrost damper closes during defrost to prevent warm air from entering the cargo area. The optional electric heater strips are also energized in defrost during electric standby operation.
Defrost can be initiated at any time the evaporator coil temperature is below 42 F (5.5 C).
There are two methods of defrost initiation:
SR-3 Microprocessor Controller: The Microprocessor
Controller is programmed to automatically initiate timed and forced defrost cycles. The SR-3 uses temperature sensors to determine if forced defrost is required.
Manual Defrost: Manual Defrost allows the operator to initiate a defrost cycle by pressing the D
EFROST key. See
“Initiating a Manual Defrost Cycle.”
30
Unit Description
DAS - Data Acquisition System
(Optional)
The DAS (Data Acquisition System) monitors and records the temperatures of (up to) six additional sensors. The sensors are independent from the microprocessor controller and are normally located in the truck box to monitor load temperatures.
DAS data can be downloaded through a serial port to an IBM ®
PC compatible computer. WinTrac™ 4.0 (or higher) software is used to view and analyze the data. Brief reports can be printed on a microprinter connected to the serial port.
CargoLink™ (Optional)
CargoLink is a wireless sensor system. The main components are the coordinator module, interconnect harness, antenna, and wireless sensors. The coordinator module receives information from the wireless sensors through the antenna, and communicates with the controller through the interconnect harness. Currently, only wireless door switches are available.
Other wireless sensors will be available in the future. Refer to
TK 55151 the Truck and Trailer Edition CargoLink Installation
Manual for information about installing the CargoLink system and sensors, and troubleshooting problems with the system.
Electric Standby (Model 50 Units
Only)
The Electric Standby option allows the unit to be operated on either the diesel engine or external electric power.
DANGER: High voltage AC power is present whenever the unit is operating in the Electric mode and whenever the unit is connected to external standby power. Voltages of this magnitude can be lethal. Exercise extreme caution when working on the unit.
31
Unit Description
Standard Model 50 Features
The following features are standard equipment on units equipped with Electric Standby.
Automatic Diesel/Electric Selection: The unit will automatically switch to electric operation when a power cord is connected and the standby power is switched On.
Overload Relay: The overload relay is self-resetting.
Hot Gas Heat: Hot gas heat is utilized on all units.
Automatic Phase Correction: The control system features two motor contactors. This allows correct motor rotation regardless of phase rotation on the incoming power.
Optional Model 50 Features
The following features are available as options on units equipped with Electric Standby.
• Electric Heater Strips
• Auto Switching
Engine Compartment
Components
Coolant Expansion Tank: The coolant level and temperature inside the expansion tank are monitored by the base controller. If the coolant temperature becomes too high or the level becomes too low, an alarm will occur. The expansion tank must always be completely full of coolant when cool.
Coolant Overflow Bottle: The overflow bottle captures coolant expelled from the expansion tank during normal diesel operation. Coolant returns to expansion tank when the unit is off and coolant has cooled. Coolant level in the overflow bottle must always be at or above the FULL COLD mark of the bottle when cool.
The engine must have antifreeze protection to –30 F (–34 C).
Check and add coolant in the expansion tank and overflow bottle as needed.
CAUTION: Do not remove expansion tank cap while the coolant is hot.
CAUTION: Do not add Green or Blue-Green coolants to cooling systems that use Red Extended
Life Coolants.
32
Unit Description
Engine Oil Dipstick: Use the engine oil dipstick to check the engine oil level.
Receiver Tank Sight Glass: The receiver tank sight glass is used to assist in checking the amount of refrigerant in the system.
Compressor Oil Sight Glass: The compressor oil sight glass is used to check the relative level of compressor oil in the compressor sump.
Unit Protection Devices
High Pressure Cutout Switch (HPCO): This normally closed switch monitors the discharge pressure at the compressor. It opens on high discharge pressure to shut the unit down to prevent damage.
Suction Pressure Regulator (SPR): This component is a mechanical control device used to limit the suction pressure to the compressor. The valve controls suction pressure based on the actual system pressure. (Scroll compressor units: The SPR is not used if the unit is equipped with an ETV.)
Electronic Throttling Valve (ETV): (Scroll compressor units only.) This component is an electromechanical control device used to limit the suction pressure to the compressor. The valve is controlled by the microprocessor controller.
Engine Oil Pressure Switch/Sensor: The engine oil pressure switch/sensor is located on the filter head above the bypass oil filter. Engine oil pressure should rise immediately on starting. If engine oil pressure drops below 10 ± 2 psig (69 ±
14 kPa), the switch/sensor signals the microprocessor to stop the engine.
Preheat Buzzer: The preheat buzzer sounds when the
CYCLE-SENTRY system energizes the glow plugs. This should warn anyone near the unit that the CYCLE-SENTRY system is about to start the diesel engine.
Coolant Temperature Sensor: This sensor provides an engine coolant temperature input to the microprocessor. If the engine coolant temperature is too high, the controller stops the unit and records an alarm.
Electric Motor Overload Relay (Model 50): The overload relay protects the electric standby motor. The overload relay opens the circuit from the contactor to the electric motor if the motor overloads for any reason and an alarm will occur. The relay resets when the alarm code is cleared.
Fuses: Sizes and functions are described in the Specifications section of this manual.
33
Unit Description
34
Figure 14: T-680S Front View (T-680R, T-880S and T-880R are similar)
Unit Description
Figure 15: T-1080S Front View (T-1080R is similar)
35
Unit Description
1
2 3
4
5
6
7
8
1.
Engine (oil dipstick on side of engine) 5.
Alternator
2.
Coolant Overflow Bottle
3.
Coolant Expansion Tank
4.
Electric Motor
6.
7.
8.
Compressor (reciprocating shown)
Dehydrator (Filter-Drier)
On/Off Switch
Figure 16: Main Components
36
Unit Operation
Premium HMI Control Panel
The Premium Truck HMI (Human/Machine Interface) Control
Panel is available as an option on SR-3 Truck applications. It is used to operate the unit, display unit information and access all
SR-3 Maintenance and Guarded Access Menus. The Premium
HMI Control Panel communicates with the base controller via the CAN (Controller Area Network) bus. It is connected to the base controller via CAN Connector J14 on the interface board.
The Premium HMI Control Panel is typically located in the vehicle driver's compartment. It may be installed in the truck instrument panel using a DIN mounting ring or under the instrument panel using an under dash mounting kit.
Figure 17: Premium HMI Control Panel
The HMI control panel consists of a display and 8 touch-sensitive keys.
The display is capable of showing both text and graphics.
The keys on the left and right sides of the display are dedicated single function "hard" keys.
The four keys under the display are "soft" keys. The functions of these soft keys change depending on the operation being performed. If a soft key is active the current key function is shown in the display directly above the key.
37
Unit Operation
Controller Features
• Displays Box Temperature and Setpoint in Fahrenheit or
Celsius
• Displays Engine Running and Motor Running Hourmeters
• Changes Setpoint
• Indicates Alarm Condition Exists
• Displays and Clears Alarms
• Selects and Indicates CYCLE-SENTRY or Continuous
Mode Operation
• Selects and Indicates High Speed Lock-Out Operation
• Initiates and Indicates a Defrost Cycle
• Initiates and Indicates a Pretrip Test
• Sends a Start of Trip to the ServiceWatch data logger.
Display
The display presents information to the operator. This information includes setpoint and temperature, unit operating information, gauge readings, temperatures and other information as selected by the operator.
The Standard Display of box temperature and setpoint is shown here. The CYCLE-SENTRY Icon in the upper right of the display shows the unit is running in CYCLE-SENTRY
(Start-Stop) Mode. The unit has a setpoint of 35 F, and an actual box temperature of 35.8 F. The down-pointing arrow at the left side of the display shows the unit is cooling.
The four keys under the display are termed "soft" keys. The functions of these keys change depending on the operation being performed. The function of each soft key is shown by labels in the display located directly above each soft key. In the example shown above, pressing the left soft key accesses the
SETPOINT Menu and pressing the right soft key accesses the
MAIN Menu. The other two soft keys access the GAUGES menu and SENSORS menu as shown by the labels above the keys.
Figure 18: Display
38
Unit Operation
Keys
Figure 19: Keys
Hard Keys
The keys on either side of the display are dedicated or "hard" keys. Their function always remains the same.
Hard Key Description
This key is used to turn the unit on. First the display will briefly show the Thermo
King Logo and then the statement
"Configuring System - Please Wait".
When the power-up sequence is complete the display shows the Standard
Display of box temperature and setpoint.
For more information see "Turning the
Unit On and Off" later in this section.
This key is used to turn the unit off. First the display will briefly show "System is
Powering Down - Please Wait. Press On to Resume" and then "Off" will appear momentarily. When the power-down sequence is complete the display will be blank. For more information see "Turning the Unit On and Off" later in this section.
39
Unit Operation
Hard Key Description
This key is used to initiate a manual defrost cycle. For more information see
"Initiating a Manual Defrost Cycle" later in this section.
This key is used to lock out high speed operation in noise sensitive areas. For more information see "Selecting High
Speed Lockout" later in this section.
Figure 20: Soft Keys
Soft Keys
Soft Key Description
The four "soft" keys under the display are multi-purpose keys. Their function changes depending on the operation being performed. If a soft key is active the key function is shown in the display directly above the key. The keys are numbered from left to right, with Key 1 on the far left and Key 4 on the far right.
Typical soft key functions:
• MENU
•
•
•
•
NEXT
YES
+
SELECT
BACK
NO
-
EXIT
• CLEAR HELP
• HOUR METERS SENSORS
• GAUGES
40
Unit Operation
Turning the Unit On and Off
IMPORTANT: Verify the Base Controller On/Off Switch is turned on before turning on the HMI Control Panel. The
Base Controller On/Off switch is located on the outside of the control box side of the unit.
If the Premium Truck HMI Control Panel is turned on and the
Base Controller On/Off Switch is turned off, the HMI display screen will briefly show LOST CONTROLLER POWER. The
HMI will then power down.
The unit is turned on by pressing the ON key and off by pressing the OFF key. When the ON key is pressed the display briefly shows the THERMO KING Logo as the display initializes.
IMPORTANT: The ON key must be held down until the
Thermo King Logo appears as shown in Figure 21. If the ON
key is not held down long enough (approximately ½ second), the display may flicker but the unit will not start up. If this occurs, hold the ON key down until the Thermo King logo appears.
NOTE: With extremely cold ambient temperatures it may take up to 15 seconds for the display to appear on initial startup.
Figure 21: Thermo King Logo
Then the startup screen shown in Figure 22 appears while
communications are established and the unit prepares for operation.
Figure 22: Startup Screen
41
Unit Operation
If More Than One Language is
Enabled
If more than one language has been enabled, a prompt will appear to allow the desired language to be chosen as shown below. Only languages enabled from the Guarded Access
Menu are available. If a different language is desired, press the
Figure 24: YES Key
The display will briefly show PROGRAMMING
LANGUAGE - PLEASE WAIT in the new language as shown
Figure 23: NO key
The Language menu will appear as shown in Figure 24. Press
the + or - keys to select the desired language. When the desired language is shown press the YES key to confirm the choice.
Figure 25: Programming Language
The new language is confirmed, and then the Standard Display
will appear in the new language as shown in Figure 26. The
unit is ready to run.
42
Unit Operation
The Language Menu will appear in the current language as
shown in Figure 28. Press the + or - keys to select the desired
language. When the desired language is shown press the YES key to confirm the choice. Note that all languages in the installed software can be selected using this method.
Figure 26: Standard Display
Should it be necessary to change to another language at any time, return to the Standard Display and then press and hold the
first and last soft keys for 5 seconds as shown in Figure 27. The
Standard Display below is shown in Deutsch (German).
Figure 28: Language Menu
When the unit is ready to run the Standard Display appears.
Figure 27: First and Last Soft Keys
Figure 29: Standard Display
43
Unit Operation
Pressing the OFF key stops unit operation. The unit shuts down immediately and the display briefly shows the power down message.
The Standard Display
The Standard Display is the default display that appears if no other display function is selected. The Standard Display shows the box temperature and setpoint. The box temperature is that measured by the controlling sensor, usually the return air
sensor. The box temperature in Figure 32 is 35.8 F with a 35 F
setpoint.
Figure 30: Power Down Message
The display briefly shows OFF and then goes blank. To start the unit again, press the ON key.
Figure 31: Off Display
Figure 32: Standard Display
The CYCLE-SENTRY Icon in the upper right corner of the display shows that the unit is operating in CYCLE-SENTRY
Mode. If the CYCLE-SENTRY Icon is not present, the unit is operating in Continuous Mode.
The down-pointing arrow indicates that the unit is cooling. If the unit was heating the arrow would be pointing upward.
44
Unit Operation
Pressing the left soft key allows the user to change the
SETPOINT, and pressing the right soft key accesses the MAIN
MENU. The other two soft keys access the GAUGES menu and the SENSORS menu.
Changing the Setpoint
From the Standard Display, press the SETPOINT soft key.
Figure 34: Setpoint Display
The "-" and "+" soft keys are used to increase or decrease the
setpoint until the desire setpoint is shown. In Figure 35 the
setpoint has been changed to 40 F using the "+" key.
Figure 33: SETPOINT Key
The setpoint display appears as shown in Figure 34.
Figure 35: Increase Setpoint
45
Unit Operation
The YES and NO soft keys confirm the setpoint change. When the desired setpoint has been selected using the "+" and/or "-" keys, press the YES soft key to confirm and load the new setpoint. If the setpoint is changed using the "+" or "-" keys, the change must be confirmed or rejected by pressing the YES or NO soft key within 10 seconds of changing the setpoint.
Failure to confirm the new setpoint by pressing YES or NO within 10 seconds of changing the setpoint will result in no setpoint change. In addition, Alarm Code 127 Setpoint Not
Entered is set, to indicate that the setpoint change was not completed.
After the YES soft key has been pressed, the display briefly shows PROGRAMMING NEW SETPOINT - PLEASE WAIT.
The display then confirms the new setpoint for several seconds.
Figure 37: New Setpoint
If the NO soft key is pressed the display will briefly show
SETPOINT NOT CHANGED and return to the Standard
Display. The Standard Display will show the old setpoint.The display then returns to the Standard Display showing the new
setpoint. Notice in Figure 38 that the arrow now points up to
indicate that the unit is heating.
Figure 36: Soft Keys
46
Unit Operation
Figure 38: Standard Display, New Setpoint
IMPORTANT: If the setpoint is changed using the "+" or
"-" keys, the change must be confirmed or rejected by pressing the YES or NO soft key within 10 seconds of changing the setpoint.
• If the YES key is pressed, the setpoint change made with the "+" or "-" key is accepted, the setpoint changes, and the display returns to the Standard Display.
• If the NO key is pressed the setpoint change made with the
"+" or "-" key is not accepted, the setpoint is not changed, and the display returns to the Standard Display.
• If either the YES or NO key is not pressed within 10 seconds of making a change with the "+" or "-" key, the setpoint is not changed, and the display returns to the
Setpoint Display. The display briefly shows [SETPOINT
NOT CHANGED] and Alarm Code 127 Setpoint Not
Entered is set, to indicate that a setpoint change was started but not completed.
Starting the Diesel Engine
Diesel engine preheats and starts are automatic in both
Continuous Mode and CYCLE-SENTRY Mode. The engine will preheat and start as required when the unit is turned on.
The engine preheat and start will be delayed in
CYCLE-SENTRY mode if there is no current need for the engine to run. If any keys are being pressed on the HMI control panel the engine will not preheat and start until 10 seconds after the last key is pressed
NOTE: If the unit is equipped with optional Electric Standby there may be some additional prompts before the engine will start. See STARTING THE ELECTRIC MOTOR on the following pages for details.
CAUTION: The engine may start automatically any time the unit is turned on.
WARNING: Never use starting fluid.
47
Unit Operation
When the engine is preparing to start the HMI control panel
will display the engine start screen, as shown in Figure 39. The
preheat buzzer sounds during the engine preheat and crank sequence.
Figure 39: Engine Start Screen
After the engine is started the display returns to the Standard
Display of temperature and setpoint.
Starting the Electric Motor
Units equipped with the Electric Standby option only.
Electric motor starting is automatic in both Continuous Mode and CYCLE-SENTRY Mode. The motor will start as required when the unit is turned on. If any keys are being pressed on the
HMI control panel prior to the motor start, the motor start will be delayed until 10 seconds after the last key is pressed.
CAUTION: The motor may start automatically any time the unit is turned on.
When the motor is preparing to start the HMI control panel will
display the motor start screen, as shown in Figure 41. The
preheat buzzer sounds for 20 seconds before the electric motor starts.
48
Figure 40: Standard Display of Temperature and
Setpoint
Figure 41: Motor Start Screen
Unit Operation
After the motor is running the display returns to the Standard
Display of temperature and setpoint.
Figure 42: Standard Display of Temperature and
Setpoint
Switching from Diesel to Electric
Units equipped with the Electric Standby option only.
If the Diesel to Electric Autoswitch Enabled feature in
Guarded Access is set YES then the unit will automatically switch to Electric Mode operation when standby power is connected and available.
If the Diesel to Electric Autoswitch Enabled feature in
Guarded Access is set NO then the prompt screen shown in
Figure 43 will appear when standby power is connected and
available.
Figure 43: Prompt Screen, Guarded Access Set to No
If YES is selected then the display will briefly show the screen
Figure 44: Prompt Screen, Guarded Access Set to Yes
Electric Mode operation will briefly be confirmed. If unit operation is required the electric motor will start as shown in
STARTING THE ELECTRIC MOTOR.
49
Unit Operation
Switching from Electric to Diesel
Units equipped with the Electric Standby option only.
If the Electric to Diesel Autoswitch Enabled feature in
Guarded Access is set YES then the unit will automatically switch to Diesel Mode operation when standby power is turned off or is no longer available.
If the Electric to Diesel Autoswitch Enabled feature in
Guarded Access is set NO then the prompt screen in Figure 45
will appear when standby power is turned off or is no longer available. Alarm Code 91 Check Electric Ready Input and
Alarm Code 84 Restart Null will both be set.
Turn the unit off and back on using the OFF and ON Keys.
This will clear Alarm Code 91 Check Electric Ready Input and
Alarm Code 84 Restart Null.
NOTE: The CLEAR Soft Key will not clear these two alarms.
Then the prompt screen shown in Figure 46 will appear.
Figure 46: Prompt Screen, after OFF and ON
If YES is selected then the display will briefly show the screen
in Figure 47. Then Diesel Mode operation will briefly be
confirmed.
Figure 45: Prompt Screen, standby power is turned off or is no longer available
50
Unit Operation
Figure 47: Display is YES is selected
If unit operation is required the diesel engine will start as shown previously in STARTING THE DIESEL ENGINE.
Figure 48: Press Defrost Key
The display briefly shows [DEFROST], [PROGRAMMING
DEFROST - PLEASE WAIT] and then [DEFROST
STARTED].
Initiating a Manual Defrost Cycle
Defrost cycles are usually initiated automatically based on time or demand. Manual defrost is also available.
Manual defrost is available if the unit is running and the evaporator coil temperature is less than or equal to 45°F (7°C).
Other features such as door switch settings may not allow manual defrost under some conditions. To initiate a manual
defrost cycle, press the Defrost Key as shown in Figure 48.
Figure 49: Prompt Screen, Guarded Access Set to Yes
51
Unit Operation
The display then shows the Defrost display. The bar indicator shows approximately how much time remains to complete the
defrost cycle. The bar indicator in Figure 49 shows that the
defrost cycle is about 25% complete.
Figure 50: Defrost Display
Terminating a Defrost Cycle
The defrost cycle terminates automatically when the coil temperature is greater than or equal to 52 F (11 C) or the defrost timer expires. Defrost can also be terminated by turning the unit off and back on.
Selecting High Speed Lockout
Mode (If Enabled)
High speed operation can be locked out in noise sensitive areas if required.
NOTE: High Speed Lockout Enable must be set to [Enabled] in the Guarded Access/Programmable Features Menu or this feature will not be available.
IMPORTANT: HIGH SPEED LOCKOUT TIMEOUT: If
High Speed Lockout Mode is selected, the High Speed Inhibit
Timeout feature may be set to return the unit to normal operation after a set time period has expired. This prevents extended operation with high speed operation locked out. The time period may be from 15 minutes to 2 hours. If the time period is set and is exceeded the unit will return to normal operation, with high speed operation allowed. If this occurs, the message HIGH SPEED LOCKOUT ACTIVE at the top of the display will disappear. If necessary to return to High
Speed Lockout Mode, press the High Speed Lockout Key again.
52
Unit Operation
The High Speed Lockout Key is a toggle. If high speed is currently allowed, then pressing the High Speed Lockout Key will disable high speed operation. Pressing the High Speed
Lockout Key again will allow high speed operation. To change the setting, press the High Speed Lockout key as shown below.
Figure 51: High Speed Lockout Key
The display will briefly show [PROGRAMMING HIGH
SPEED LOCKOUT - PLEASE WAIT].
Figure 52: PROGRAMMING HIGH SPEED LOCKOUT -
PLEASE WAIT
The change is confirmed by briefly displaying [HIGH SPEED
LOCKOUT ACTIVE] or [HIGH SPEED LOCKOUT
INACTIVE].
Figure 53: High Speed Lockout Display
53
Unit Operation
The display will then return to the Standard Display. If High
Speed Lockout is turned on, the message HIGH SPEED
LOCKOUT ACTIVE will be shown at the top of the display.
Using the Gauges Key
The GAUGES key allows the operator to view the unit gauges.
To access the GAUGES menu press the GAUGES key.
Figure 54: Standard Display, High Speed Lockout
Active
Pressing the High Speed Lockout key again will turn the feature off.
Selecting CYCLE-SENTRY or
Continuous Mode
With Thermo King Truck unit applications, CYCLE-SENTRY
Mode or Continuous Mode operation is selected from the Main
Menu - Mode Submenu. See the Main Menu - Mode Submenu material later in this section for complete details.
Figure 55: Gauges Key
The first gauge display will appear. Press the NEXT and
BACK keys to scroll thru the gauges as desired. The Battery
Voltage Gauge is shown in Figure 56. Press the LOCK key to
lock the selected gauge on the display.
54
Unit Operation
Figure 56: Next, Back, Lock Keys
The gauges available are shown in the following list. The order in which the gauges appear may vary slightly based on software revision. Not all gauges may appear, depending on unit configuration and software revision
To return to the Standard Display press the EXIT key.
Gauges Available
NOTE: Not all gauges or I/O states will appear, dependent upon unit type and configuration
Coolant Temperature - Displays the temperature of the engine coolant.
Coolant Level - Displays the coolant level in the overflow tank as OK or LOW.
Oil Pressure - Displays the engine oil pressure as OK or LOW.
Oil Level - Displays the engine oil level as OK or LOW.
Amps - Displays the current flow in amps to or from the unit battery.
Battery Voltage - Displays the voltage of the unit battery.
Engine RPM - Displays the engine speed in RPMs.
Discharge Pressure - Displays the unit discharge pressure.
(ETV units only)
Suction Pressure - Displays the unit suction pressure. (ETV units only)
ETV Position - Displays the current position of the Electronic
Throttling Valve (ETV). (ETV units only)
Compressor Temperature - Displays the temperature sensed by the compressor temperature sensor.
I/O (Input/Output State) - Displays the current state of the input/output devices listed below as ON or OFF.
55
Unit Operation
• High Speed Relay/Electric Heat
• Run Relay
• Run Relay Feedback
• Alternator Excite Output
• Defrost Damper
• Hot Gas Solenoid
• Alternator Frequency
• Diesel/Electric Relay (Model 50 units only)
• Electric Ready Input (Model 50 units only)
• Electric Overload (Model 50 units only)
• Condenser Inlet Solenoid
• Drain Hose Heater
• Purge Valve
Using the Sensors Key
The SENSORS key allows the operator to view the temperatures read by the unit temperature sensors. To access the SENSORS menu press the SENSORS key.
Figure 57: Sensors Key
The first sensor display will appear. Press the NEXT and
BACK keys to scroll thru the sensors as desired. The Discharge
Air Temperature sensor is shown in Figure 58. Press the LOCK
key to lock the current sensor on the display.
Figure 58: Next, Back, Lock Keys
56
Unit Operation
The sensors available are shown in the following list.
To return to the Standard Display press the EXIT key.
Sensors Available
Return Air Temperature - Displays the temperature of the control return air sensor.
Discharge Air Temperature - Displays the temperature of the control discharge air sensor.
Temperature Differential - Displays the calculated difference between the control return air sensor and the control discharge air sensor.
Evaporator Coil Temperature - Displays the temperature of the evaporator coil sensor.
Ambient Air Temperature - Displays the temperature of the ambient air sensor.
Data Logger Sensor 1 Temperature - Display the temperature of Data Logger Sensor 1.
Data Logger Sensor 2 Temperature - Display the temperature of Data Logger Sensor 2.
Data Logger Sensor 3 Temperature - Display the temperature of Data Logger Sensor 3.
Data Logger Sensor 4 Temperature - Display the temperature of Data Logger Sensor 4.
Data Logger Sensor 5 Temperature - Display the temperature of Data Logger Sensor 5.
Data Logger Sensor 6 Temperature - Display the temperature of Data Logger Sensor 6
Using The Main Menu
The Main Menu contains several additional submenus that allow the operator to view information and modify unit operation. To access the Main Menu press the MENU key.
57
Unit Operation
Figure 59: Menu Key
The first Main Menu choice will appear. Press the NEXT and
BACK keys to scroll thru the menu choices. When the desired selection is shown on the display, press the SELECT key to
access it. The Pretrip submenu is shown in Figure 60.
Figure 60: Pretrip Submenu
See “Main Menu Choices.” For detailed information see the individual explanations of each submenu item on the following pages.
To return to the Standard Display press the EXIT key.
Main Menu Choices
LANGUAGE - If more than one language is enabled, this will be the first menu item to appear. If only one language is enabled, this menu will not appear. The Language Menu allows the operator to select a language from a list of up to 11 languages at one time. All subsequent displays are shown in the selected language. Three different language packages with a total of 23 languages are available. English is the default language and is provided in each of the packages.
ALARMS - Allows the operator to view all alarms, and allows most alarms to be cleared. If only one language is enabled this will be the first menu item to appear.
DATA LOGGER - Allows the operator to set a Start of Trip marker to the ServiceWatch data logger. Also allows a Start of
Trip and Print requests to be sent to the Optional DAS Data
Logger (if installed).
58
Unit Operation
HOURMETERS - Allows the operator to view the unit hourmeters that have the view feature enabled in the Guarded
Access menu. If the view feature for a particular hourmeter is not enabled then that hourmeter will continue to accumulate time but cannot be viewed from the Main Menu. However, all hourmeters can be viewed from the Maintenance Menu, even if they are not enabled.
MODE - Allows the operator to change the unit operating modes if allowed. Not all modes may appear depending on the settings selected from the Guarded Access menu and the HMI
Control Panel software version.
• "Turn Off CYCLE-SENTRY Mode/Turn On
CYCLE-SENTRY Mode (If CYCLE-SENTRY is Off unit runs in Continuous).
• Allow Keypad Lockout to be selected.
• Start Sleep Mode.
PRETRIP - Allows the operator to start a Pretrip Test. If an alarm is active, the Pretrip Test is not allowed and the operator is prompted to clear the alarm(s).
ELECTRIC STANDBY - If the Electric Standby option is present and the Diesel to Electric Auto-switch feature is set
NO, this feature allows the operator to manually select electric mode operation. This feature does not appear if the unit does not feature optional Electric Standby or if the Diesel to Electric
Auto-switch feature is set YES.
DIESEL MODE - If a unit equipped with electric standby is running in electric mode and the Electric to Diesel Auto-switch feature is set NO, this feature allows the operator to manually select diesel mode operation. This feature does not appear if the unit does not feature optional Electric Standby or if the
Electric to Diesel Auto-switch feature is set YES.
ADJUST BRIGHTNESS - Allows the operator to adjust the
HMI Control Panel display backlight intensity as required by local conditions.
TIME - Allows the operator to view the unit time and date. The time and date cannot be changed from this menu.
59
Unit Operation
Languages
If the Language feature is enabled, an alternate language can be selected from the Language Menu. After a new language is chosen, all subsequent displays will appear in that language. If the language feature is not enabled this menu does not appear.
The default language is English. Only languages that have been enabled in Guarded Access will appear. Exercise care when changing languages, as once changed all HMI Control panel displays will be in the new language. If the user is not familiar with the new language, problems may be experienced returning to the default language.
The languages available are dependent on the HMI control panel software revision.
• Languages currently supported by software revision 65xx are English, Spanish, French, German, Italian, Dutch,
Portuguese, Greek, Turkish, Hebrew and Arabic.
• Languages currently supported by software revision 66xx are English, Danish, Russian, Norwegian, Swedish,
Finnish, Polish, Hungarian, Romanian, Bulgarian and
Czech.
• Languages currently supported by software revision 67xx are English, Japanese and Chinese. Other than the languages supported, software revisions 65xx, 66xx and
67xx are functionally identical.
To select an alternate language, press the MENU key.
Figure 61: Menu Key
If enabled, the Language Menu is the first menu item to appear
as shown in Figure 62. Press the SELECT key to choose the
Language menu.
60
Unit Operation
The display will briefly show PROGRAMMING
LANGUAGE - PLEASE WAIT in the new language as shown
Figure 62: Select Key
The Language menu will appear as shown in Figure 63. Press
the + or - keys to select the desired language. When the desired language is shown press the YES key to confirm the choice.
Figure 64: New Language
The new language is confirmed, and then the Standard Display
will appear in the new language as shown in Figure 65. The
unit is ready to run.
Figure 63: + or - Keys, Yes Key
Figure 65: Standard Display in New Language
61
Unit Operation
Repeat the process to select a different language. To select a different Main Menu item press the NEXT key. To return to the
Standard Display press the EXIT key.
IMPORTANT: If necessary, English and all other languages in the installed HMI Control Panel software revision may be accessed from the Standard Display.
Should it be necessary to change to another language at any time, return to the Standard Display and then press and hold the
first and last soft keys for 5 seconds as shown in Figure 66. The
Standard Display below is shown in Deutsch (German).
press the YES key to confirm the choice. Note that all languages in the installed HMI Control Panel software (65xx,
66xx or 67xx) can be selected using this method.
Figure 67: Language Menu
Alarms
Alarm Types
Alarms may be one of four types as shown.
Figure 66: Standard Display in New Language
After 5 seconds the Language Menu will appear in the current
language as shown in Figure 67. Press the + or - keys to select
the desired language. When the desired language is shown
62
Unit Operation
Log Alarms
Log Alarms are indicated for 60 seconds each time the unit is turned on. This level of alarm serves as a notice to take corrective action before the condition impacts unit performance. Maintenance items such as maintenance hourmeter time-outs are log alarms.
When the unit is turned on the display will show the Thermo
King Logo and then the "Configuring System" message. If log alarm(s) are present the Log Alarm notice will appear on the display for 60 seconds as shown. The amber K symbol of the remote indicator alarm light (if installed) will also be on during this period. The Standard Display will appear and the remote indicator alarm light will go to the white T symbol after 60 seconds.
NOTE: The Alarm Icon does not appear on startup with log alarms present.
Figure 68: Log Alarm Notice
NOTE: If required, an engine start may occur while the
display in Figure 68 is shown. This is normal operation.
Check Alarms
Check Alarms are indicated by an Alarm Icon in the display.
The amber K symbol of the remote indicator alarm light (if installed) will be on. This level of alarm serves as a notice to take corrective action before a problem becomes severe. The unit will run with check alarms but some features and functions may be inhibited.
63
Unit Operation
Shutdown Alarms
Shutdown alarms will be set if continued operation could cause damage to the unit or the load. Shutdown Alarms are indicated by the following:
• The Alarm Icon will appear in the display.
• The display and backlight will flash on and off.
• The display will switch from normal video to reverse video and back to normal video. (Light areas become dark and dark areas become light.)
• The remote indicator alarm light (if installed) will display only a row of LEDs at the bottom.
Shutdown alarms will force the unit into shutdown to prevent potential damage to the unit or load. The unit will remain in shutdown until the shutdown alarm is manually cleared.
Exceptions are some engine and electric shutdown alarms that become log alarms when switched to the alternate operating mode (diesel to electric or electric to diesel).
Prevent Alarms
Prevent Alarms are also indicated by a steady Alarm Icon in the display. The remote indicator alarm light (if installed) will be on. The unit will attempt to resolve the situation as shown below.
• The unit will be temporarily shut down if a Prevent Alarm is active.
• The unit will remain shut down for a timed restart interval or until the fault conditions are corrected.
• If the unit is in a temporary shutdown, Alarm Code 84
Restart Null will be present along with the associated
Prevent Alarm.
• The unit will restart and run (in most cases with forced reduced performance) to determine if continued operation is possible. The unit will run in this manner for a timed interval. If the unit is running with forced reduced performance, Alarm Code 85 Forced Unit Operation will also be present under some conditions.
• If the alarm does not reoccur during the timed running interval with reduced performance, the unit will return to full performance to determine if continued operation is
64
Unit Operation possible. The unit will run in this manner for a timed interval. If the unit is successfully able to return to full performance for the timed interval without the alarm re-occurring, the alarm is auto cleared and the unit will run normally.
• All Prevent Alarm events and conditions are logged by the
ServiceWatch Data Logger.
• In general, if the alarm condition re-occurs a defined number of times, the alarm is set as a shutdown alarm and no further restarts are possible.
NOTE: If the Restart After Shutdown feature in the Guarded
Access Menu is set for CONTINUOUS, then an unlimited number of restart attempts are allowed.
Pretrip Alarm Codes
If an alarm occurs during a Pretrip Test the alarm code will be displayed as Pretrip Alarm XX, where XX is the alarm code.
Alarm Codes When Switching Between
Diesel and Electric
If a shutdown alarm occurs that affects only diesel mode operation and the unit is switched to electric, the diesel mode shutdown alarm becomes an electric mode log alarm. This allows the unit to run in electric mode without clearing the shutdown alarm that is preventing diesel mode operation. If the unit is switched back to diesel mode, the alarm again become a diesel mode shutdown alarm and prevents unit operation.
In the same manner, if a shutdown alarm occurs that affects only electric mode operation and the unit is switched to diesel, the electric mode shutdown alarm becomes a diesel mode log alarm to allow diesel mode operation. If the unit is switched back to electric mode, the alarm reverts to an electric mode shutdown alarm and prevents unit operation. If the unit is configured for electric to diesel autoswitch, it automatically starts and runs in diesel mode if an electric shutdown occurs.
Alarm Code Notification
The Alarm Icon used in previous Thermo King controllers has been incorporated. If a Check alarm condition occurs the
Alarm Icon will appear in the display as shown in Figure 69.
65
Unit Operation
Figure 69: Alarm Icon
If a Shutdown Alarm occurs it will be indicated by all of the following:
1.
The Alarm Icon will appear.
2.
The display and backlight will flash on and off.
3.
The display will switch from normal video to reverse video and back to normal video. (Light areas become dark and dark areas become light.)
Clearing Alarm Codes
Most alarm codes can be cleared conventionally from the
Alarm Menu using the CLEAR key.
The following control and display sensor alarm codes can only be cleared from the Maintenance Menu or Guarded Access
Menu:
• Alarm Code 03 Check Control Return Air Sensor
• Alarm Code 04 Check Control Discharge Air Sensor
The following alarm codes clear automatically.
• Alarm Code 64 Pretrip Reminder - Clears when a Pretrip
Test is performed.
• Alarm Code 84 Restart Null - Clears when the unit is no longer in a restart null due to a Prevent Alarm.
• Alarm Code 85 Forced Unit Operation - Clears when the unit is no longer running in a forced mode due to a Prevent
Alarm.
• Alarm Code 91 Check Electric Ready Input - Clears automatically when the unit starts running.
• Alarm Code 92 Sensor Grades Not Set - Clears when the sensor grade is changed from 5H.
66
Unit Operation
If the Limited Alarm Restarts feature is enabled the following additional alarm codes may only be cleared from the Guarded
Access Menu. If this is the case, the CLEAR soft key will not appear if the alarms are displayed from the Main Menu or the
Maintenance Menu.
• Alarm Code 10 High Discharge Pressure
• Alarm Code 23 Cooling Cycle Fault
• Alarm Code 24 Heating Cycle Fault
• Alarm Code 32 Refrigeration Capacity Low
Displaying and Clearing Alarm Codes
Alarms are displayed and cleared using the Alarm Menu. From the Standard Display, press the MENU key.
The Language Menu or Alarms Menu will appear. If the
Language Menu appears press the NEXT key to show the
Alarm Menu. When the Alarms Menu is shown press the
SELECT key.
Figure 71: Select Key
The Alarm Display will appear. If no alarms are present NO
ALARMS will be shown.
Figure 70: Menu Key
Figure 72: No Alarms
67
Unit Operation
If alarms are present, the quantity of alarms (if more than one) and the most recent alarm code number will be shown. In the
the ambient temperature sensor.
Figure 73: Alarm Code 6
After the alarm situation is resolved press the CLEAR key to clear the alarm. For additional information regarding the alarm shown on the display, press the HELP key. To display the next alarm, press the NEXT key.
Figure 74: Next Key
If a serious condition occurs, the unit will be shut down to prevent damage to the unit or the load. If this occurs, the display will show that the unit is shut down and display the
alarm code that caused the shutdown. In the example in Figure
75, the unit is shut down due to low oil level. For additional
information regarding the alarm shown on the display, press the HELP key.
68
Unit Operation
Figure 75: Help Key
A help message will appear. For the alarm shown in Figure 75,
the message "CHECK OIL LEVEL. IF UNIT IS SHUT
DOWN, REPAIR IMMEDIATELY. OTHERWISE, REPORT
ALARM AT END OF THE DAY" will be shown on the display. Check the oil level and add oil as required, clear the alarm and restart the engine.
To select a different Main Menu item press the NEXT key. To return to the Standard Display press the EXIT key.
Important Alarm Notes
• If an alarm will not clear, it may still exist. If the alarm is not corrected, it will not clear or may be immediately set again.
• If an alarm cannot be cleared from the Main menu, the
Clear key will not appear. These alarms must be cleared from the Maintenance or Guarded Access Menus.
• All alarms must be viewed before any of the alarms can be cleared.
SR-3 Alarm Codes
NOTE: Not all alarm codes are used with all applications.
Code Description
0 No Alarms Exist
2
3
4
Operator Help
Check Evaporator
Coil Sensor
Check (Control)
Return Air Sensor
Manually monitor load temperature. Report alarm at end of the day.
Manually monitor load temperature. Report alarm at end of the day.
Check (Control)
Discharge Air Sensor
Manually monitor load temperature. Report alarm at end of the day.
69
Unit Operation
Code Description
5
Check Ambient Air
Sensor
6
7
Operator Help
Report alarm at end of the day.
Check Coolant Temp
Sensor
Report alarm at end of the day.
Check Engine RPM
Sensor
Report alarm at end of the day.
9
10
11
12
High Evaporator
Temperature
High Discharge
Pressure
Unit Controlling on
Alternate Sensor
Sensor or Digital
Input Shutdown
Manually monitor load temperature. Report alarm at end of the day.
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
Manually monitor load temperature. Report alarm at end of the day.
The indicated zone is not longer able to operate and has been shut down.
Repair immediately.
Code
13
15
Description
Sensor Check
Operator Help
Manually monitor load temperature. Report alarm at end of the day.
Check Glow Plugs or
Intake Air Heater
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
17
18
19
Engine Failed to
Crank
High Engine Coolant
Temperature
Low Engine Oil
Pressure
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
70
Unit Operation
Code Description
20
21 Cooling Cycle Check
Operator Help
Engine Failed to Start
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
Manually monitor load temperature. Report alarm at end of the day.
22
23
24
25
Heating Cycle Check
Cooling Cycle Fault
Heating Cycle Fault
Alternator Check
Manually monitor load temperature. Report alarm at end of the day.
The indicated zone is not longer able to operate and has been shut down.
The indicated zone is not longer able to operate and has been shut down.
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
Code
26
28
29
30
Description
Check Refrigeration
Capacity
Pretrip or Self Check
Abort
Defrost Damper
Circuit Check
Defrost Damper
Stuck
Operator Help
Manually monitor load temperature. Report alarm at end of the day.
Report alarm at end of the day.
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
31
32
Check Oil Pressure
Switch
Refrigeration
Capacity Low
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
The indicated zone is not longer able to operate and has been shut down.
Repair immediately.
71
Unit Operation
Code
33
35
36
37
38
39
Description
Check Engine RPM
Check Run Relay
Circuit
Electric Motor Failed to Run
Check Engine
Coolant Level
Electric Phase
Reversed
Check Water Valve
Circuit
Operator Help
Report alarm at end of the day.
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
Report alarm at end of the day.
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
Code
40
41
42
43
44
45
Description
Check High Speed
Circuit
Check Engine
Coolant Temperature
Unit Forced to Low
Speed
Unit Forced to Low
Speed Modulation
Check Fuel System
Hot Gas or Hot Gas
Bypass Circuit
Operator Help
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
Report alarm at end of the day.
Report alarm at end of the day.
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
72
Unit Operation
Code
46
48
Description
Check Air Flow
Operator Help
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
Check Belts or Clutch
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
50
52
54
Reset Clock
Check Heat Circuit
Test Mode Timeout
Report alarm at end of the day.
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
Service Test or Interface
Board Test timed out after 15 minutes. Report alarm at end of the day.
Code
61
62
63
64
66
Description
Low Battery Voltage
Ammeter Out of
Calibration
Engine Stopped
Pretrip Reminder
Low Engine Oil Level
Operator Help
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
Report alarm at end of the day.
Check engine oil level. If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
73
Unit Operation
Code
67
68
70
74
77
79
80
Description
Check Liquid Line
Solenoid Circuit
Internal Controller
Fault Code
Hourmeter Failure
Controller Reset to
Defaults
Controller EPROM
Checksum Failure
Internal Data Logger
Overflow
Check Compressor
Temp Sensor
Operator Help
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
Report alarm at end of the day.
Report alarm at end of the day.
Report alarm at end of the day.
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
Report alarm at end of the day.
Report alarm at end of the day.
Code
81
82
83
84
85
86
87
Description
High Compressor
Temp
High Compressor
Temp Shutdown
Low Engine Coolant
Temperature
Restart Null
Forced Unit
Operation
Check Discharge
Pressure Sensor
Check Suction
Pressure Sensor
Operator Help
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
Report alarm at end of the day.
Report alarm at end of the day.
Report alarm at end of the day.
Report alarm at end of the day.
74
Unit Operation
Code
89
90
91
92
93
Description
Check Electronic
Throttling Valve
Circuit
Electric Overload
Low Compressor
Suction Pressure
Operator Help
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
Check Electric Ready
Input
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
Sensor Grades Not
Set
Report alarm at end of the day.
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
Code
94
95
96
98
99
108
Description
Check Loader #1
Circuit
Check Loader #2
Circuit
Low Fuel Level
Check Fuel Level
Sensor
High Compressor
Pressure Ratio
Door Open Timeout
Operator Help
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
Check engine fuel level.
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
Report alarm at end of the day.
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
Close Doors. Report alarm at end of the day.
75
Unit Operation
Code Description
111
Unit Not Configured
Correctly
113
114
115
Operator Help
Report alarm at end of the day.
Check Electric Heat
Circuit
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
Multiple Alarms - Can
Not Run
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
Check High Pressure
Cut Out Switch
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
116
117
118
Check High Pressure
Cut In Switch
Report alarm at end of the day.
Auto Switch from
Diesel to Electric
Report alarm at end of the day.
Auto Switch from
Electric to Diesel
Report alarm at end of the day.
Code
120
121
122
127
128
129
Description
Check Alternator
Excite Circuit
Check Liquid
Injection Circuit
Engine Run Time
Maintenance
Reminder #1
Engine Run Time
Maintenance
Reminder #2
Operator Help
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
Check Diesel/Electric
Circuit
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
Setpoint Not Entered
Be sure the setpoint is set to the required temperature.
Report alarm at end of the day.
Report alarm at end of the day.
76
Code Description
130
Electric Run Time
Maintenance
Reminder #1
131
132
133
134
135
136
137
Operator Help
Report alarm at end of the day.
Electric Run Time
Maintenance
Reminder #2
Total Unit Run Time
Maintenance
Reminder #1
Total Unit Run Time
Maintenance
Reminder #2
Controller Power On
Hours
Check Spare Digital
Inputs
Report alarm at end of the day.
Report alarm at end of the day.
Report alarm at end of the day.
Report alarm at end of the day.
Report alarm at end of the day.
Check Spare Digital
Outputs
Report alarm at end of the day.
Check Damper Motor
Heater Output
Report alarm at end of the day.
Unit Operation
Code Description
141
Autoswitch Diesel to
Electric Disabled
145
146
148
149
150
Operator Help
Report alarm at end of the day.
Loss of Controller
"On" Feedback
Signal
Software Version
Mismatch
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
Autoswitch Electric to
Diesel Disabled
Report alarm at end of the day.
Alarm Not Identified
Out of Range Low
If unit is shut down repair immediately. Otherwise, report alarm at end of the day.
Manually monitor load temperature. Report alarm at end of the day.
77
Unit Operation
Code
151
203
204
Description
Out of Range High
Check Display
Return Air Sensor
Check Display
Discharge Air Sensor
Operator Help
Manually monitor load temperature. Report alarm at end of the day.
Manually monitor load temperature. Report alarm at end of the day.
Manually monitor load temperature. Report alarm at end of the day.
The ServiceWatch Data Logger and DAS Data Logger (if equipped) are accessed using the Data Logger Menu. From the
Standard Display, press the MENU key.
Datalogger
The unit can be equipped with an optional DAS Data Logger if desired.
A Start of Trip marker can be sent to the unit ServiceWatch
Data Logger and the optional DAS Data Logger (if equipped).
If equipped with the optional DAS Data Logger, the most recent DAS trip record can be printed. The most recent trip is defined as the trip following the last Start of Trip marker sent to the data logger.
Figure 76: Menu Key
The Language Menu or Alarm Menu will appear. Press the
NEXT key as required to display the Data Logger Menu. When the Data Logger Menu is shown press the SELECT key.
Figure 77: Select Key
78
Unit Operation
The first feature that appears is the Start of Trip. To send a Start of Trip to the ServiceWatch Data Logger and DAS Data
Logger (if equipped), press the SELECT key to select the feature, and then press it again to send the Start of Trip. The display will briefly show START OF TRIP COMPLETE to confirm that a Start of Trip marker was set in the data logger(s).
Figure 78: Start of Trip
NOTE: The start of trip marker is sent to both the
ServiceWatch Data Logger and DAS Data Logger (if equipped).
Press the NEXT key to select the PRINT feature. The PRINT screen will appear. Press the SELECT key to print the most recent trip record to the optional remote printer.
Figure 79: Select Key
Pressing the EXIT key returns the display to the Main Menu.
Hourmeters
Hourmeters are displayed using the Hourmeter Menu. Only hourmeters enabled in the Guarded Access Menu will be shown. From the Standard Display, press the MENU key.
Figure 80: Menu Key
79
Unit Operation
The Language Menu or Alarm Menu will appear. Press the
NEXT key as required to display the Hourmeter Menu. When the Hourmeter Menu is shown press the SELECT key. The
Hourmeter Display will appear.
Figure 81: Hourmeter Display
Press the NEXT or PREVIOUS key to scroll through the enabled hourmeters.
Figure 82: Scroll Through Hourmeters
Hourmeter names and definitions are shown in the table below in the order they appear. Only hourmeters enabled in the
Guarded Access Menu will be shown. To return to the Standard
Display, press the EXIT key.
Hourmeter Names and Definitions
Total Hours: Total number of hours the unit has been turned on (protection hours).
Total Run Time Hours: Total number of hours the unit has run in both diesel and electric mode.
Engine Hours: Total number of hours the unit has run in diesel mode.
Electric Run Hours: Total number of hours the unit has run in electric mode.
Total Run Reminder 1: User Programmable - The number of hours before a Total Unit Run Time Maintenance Reminder
1 occurs.
Total Run Reminder 2: User Programmable - The number of hours before a Total Unit Run Time Maintenance Reminder
2 occurs.
80
Unit Operation
Controller Power On: Total hours the controller and HMI control panel have been turned on.
Pretrip Reminder : User Programmable - number of hours before a Pretrip Reminder occurs.
Engine Reminder 1: User Programmable - The number of hours before an Engine Run Time Maintenance Reminder 1 occurs.
Engine Reminder 2: User Programmable - The number of hours before an Engine Run Time Maintenance Reminder 2 occurs.
Electric Reminder 1: User Programmable - The number of hours before an Electric Run Time Maintenance Reminder 1 occurs.
Electric Reminder 2: User Programmable - The number of hours before an Electric Run Time Maintenance Reminder 2 occurs.
IMPORTANT: If a programmable hourmeter is not enabled or the view for that hourmeter is not turned on it will not appear in the display sequence.
Mode
Various operating modes can be selected using the Mode menu. Not all modes may be available, depending on settings of other programmable features. The following modes may be available.
Turn CYCLE-SENTRY On or Off
CYCLE-SENTRY Mode can be turned On or Off. If
CYCLE-SENTRY Mode is turned Off then unit will run in
Continuous mode.
Keypad Lockout
If enabled in Guarded Access, the keypad can be locked to prevent unauthorized use. If the keypad is locked only the ON and OFF keys function. The keypad will remain locked even if the unit is turned Off and back on. If Keypad Lockout is active, press and hold any soft key for 5 seconds to deactivate the feature.
81
Unit Operation
Start Sleep Mode
If enabled in Guarded Access, Sleep Mode is used to keep the engine warm and the battery charged when the unit is not in use. When the unit is in Sleep Mode the display will show
"SLEEP" and the current time. When Sleep Mode is entered the unit will start and run to confirm proper battery charge level and engine temperature.
IMPORTANT: While in Sleep Mode the unit will not monitor or maintain setpoint and load temperature. Fuel level should be monitored as the unit may run periodically, particularly in cold weather.
The following features are available in Sleep Mode.
Program Wakeup Time: This feature allows a wakeup time to be specified. When the selected time is reached the unit will start and resume normal operation.
If a Wakeup Time is selected the following features are available:
Day to Wake Up: This feature allows the day of the week the unit is to wake up to be specified.
Hour to Wake Up: This feature allows the hour the unit is to wake up to be specified.
Minute to Wake Up: This feature allows the minute the unit is to wake up to be specified.
Run Pretrip on Wakeup: This feature allows a Pretrip Test to be automatically run when the unit wakes up.
Mode changes are made using the Mode Menu. From the
Standard Display, press the MENU key.
Figure 83: Menu Key
The Language Menu or Alarm Menu will appear. Press the
NEXT key as required to show the Mode Menu. When the
Mode Menu is shown press the SELECT key.
82
Figure 84: Select Key
The first mode change screen will appear. To choose that function, press the SELECT key. To Scroll thru the Mode
Menu press the NEXT key.
Unit Operation
Selecting CYCLE-SENTRY or
Continuous Mode
.
When CYCLE-SENTRY mode is selected the unit will start and stop automatically to maintain setpoint, keep the engine warm and the battery charged. When Continuous Mode is selected, the unit will start automatically and run continuously to maintain setpoint and provide constant airflow. From the
Standard Display, press the MENU key.
Figure 85: Select and Next Keys
Figure 86: Menu Key
The Language Menu or Alarm Menu will appear. Press the
NEXT key as required to display the Mode Menu. When the
Mode Menu is shown press the SELECT key.
83
Unit Operation
Figure 87: Select Key
The Turn Off/Turn On CYCLE-SENTRY screen will appear.
In the display shown below, the unit is operating in
CYCLE-SENTRY mode. Turning CYCLE-SENTRY mode off will result in the unit running in Continuous mode.
Figure 89: Select Key
The display will confirm the change as shown below.
Figure 88: Turn Off/Turn On CYCLE-SENTRY Screen
Pressing the Select key will change the mode from
CYCLE-SENTRY to Continuous.
Figure 90: Mode Change Confirmed
The new mode is then confirmed for 10 seconds.
84
Unit Operation
Figure 91: Mode Confirmed
The display then returns to the Mode Menu. In the example here the unit is currently running in Continuous mode. Pressing the Select key again allows the operator to change back to
CYCLE-SENTRY mode operation.
Figure 92: Mode Menu
IMPORTANT: If the unit is in CYCLE-SENTRY null and the mode is switched to Continuous Mode, the unit will start automatically.
Selecting Sleep Mode
Normal CYCLE-SENTRY mode starts and stops the unit as required to maintain the desired setpoint temperature, maintain the unit battery in a charged condition and keep the unit engine warm in cold ambient conditions. Sleep mode does not consider setpoint or maintain cargo temperatures - it only keeps the engine warm and the unit battery charged. This is useful in extremely cold weather or when the unit is to be out of service for an extended time. Sleep mode operates in both
Diesel mode and Electric mode. In Diesel mode the unit will start and stop as required to maintain engine temperature and battery charge. In Electric mode the unit starts and stops as necessary to maintain battery charge only.
When Sleep mode is entered, the operator can program an automatic Wake-up Time up to a week away. Using this feature, the unit will automatically restart and run normally at the determined time. If a Wake-up Time is programmed the operator can also program an automatic Pretrip Test when the unit restarts.
Sleep Mode is turned On and Off using the Mode Menu. From the Standard Display, press the MENU key.
85
.
Unit Operation
Figure 93: Menu Key
The Language Menu or Alarm Menu will appear. Press the
NEXT key as required to show the Mode Menu. When the
Mode Menu is shown press the SELECT key.
Figure 95: Sleep Mode Menu
The screen shown in Figure 96 will appear.
Figure 94: Select Key
Press the Next key as required to display the Sleep Mode prompt. Press the Select key to choose the Sleep Mode menu.
Figure 96: Start of Sleep Mode Menu
The operator can now choose a Sleep Mode Wake-up Time or simply enter Sleep Mode immediately. If NO is pressed the unit will immediately enter Sleep Mode.
86
Unit Operation
To enter a Wake-up Time, verify the unit clock is set properly.
Then press the YES key at the Sleep Mode menu.
Figure 97: Select No to Enter Sleep Mode
The display will show SLEEP and the unit will start and stop as required to keep the engine warm and/or the battery charged.
Sleep mode does not consider setpoint or maintain cargo temperatures. To exit Sleep Mode press the EXIT key or turn the unit off and back on. The unit will resume normal operation and control to setpoint.
Figure 99: Yes Key
The display will prompt the operator for the DAY the unit is to
restart in normal operation. In Figure 100 Monday has been
chosen. Press the YES key to confirm the DAY.
Figure 100: Day Unit is to Restart
Figure 98: Sleep Mode Display
87
Unit Operation
The display will now prompt the operator for the Hour the unit
is to restart in normal operation. In Figure 101 4:00 am has
been chosen. Press the YES key to confirm the HOUR. Note that 24 hour "military time" is used.
The display will now prompt for a Pretrip Test on Wake-up.
Press the YES key to perform a Pretrip Test on Wake-up. If the
No key is pressed the unit will resume normal operation on
Wake-up.
Figure 101: Confirm Hour
The display will now prompt the operator for the MINUTE the
unit is to restart in normal operation. In Figure 102 4:30 am has
been chosen. Press the YES key to confirm the MINUTE.
Figure 103: Press Yes Key for Pretrip Test
The display will show SLEEP and the unit will start and stop as required to keep the engine warm and/or the battery charged.
Sleep mode does not consider setpoint or maintain cargo temperatures.
NOTE: The unit may start when sleep is enabled to bring battery charge level and engine temperature up to minimum level. It will shut down and then maintain minimum levels.
Figure 102: Confirm Minute
88
Unit Operation
Figure 104: Sleep Mode
The unit will restart at the programmed time (in this example
4:30 am) and perform a Pretrip Test (if selected). After the
Pretrip Test is complete the test results will be displayed and the unit will resume normal operation and control to setpoint.
To exit Sleep Mode before the selected Wake-up time press the
EXIT key or turn the unit off and back on. The unit will resume normal operation and control to setpoint.
Pretrip
A Pretrip Test verifies unit operation. This display allows a
Pretrip Test to be selected and initiated by the operator. If the
Pretrip Test is entered with the unit shut down a Full Pretrip
Test with device amp checks will be performed. If the Pretrip
Test is entered with the unit running in either diesel or electric mode a Running Pretrip Test is performed, but the device amps checks are not performed. Test results are reported as PASS,
CHECK or FAIL when the Pretrip Test is completed. If an alarm occurs during a Pretrip Test the alarm code will be displayed as Pretrip Alarm XX, where XX is the alarm code.
Pretrip Test Conditions
• Current unit settings are saved and restored at the end of the Pretrip Test or if the unit is turned off and back on.
• Pretrip Test can be run in either Diesel or Electric Mode.
• The unit will auto switch from Diesel Mode to Electric
Mode or from Electric Mode to Diesel Mode during a
Pretrip Test if these features are enabled and the auto switch conditions occur.
Conditions where Pretrip Tests are not allowed
• If any shutdown alarms are present. Pretrip tests are allowed with some Check and Log alarms.
• If the unit is in Sleep Mode.
• If the unit is in Service Test Mode, Interface Board Test
Mode or Evacuation Mode.
89
Unit Operation
Pretrip Test Sequence
Pretrip tests proceed in the order shown below. A Full Pretrip
Test includes all tests. A Running Pretrip Test is started with the engine or motor running and does not include the Amp
Checks or Engine Start Check.
• Amp Checks - Each electrical control component is energized and the current drawn is confirmed as within specification.
• Engine Start - The Engine will start automatically.
• Defrost - If the coil temperature is below 45 F (7 C), a defrost cycle is initiated.
• RPM Check - The engine RPM in high and low speed is checked during the Cool Check.
• Cool Check - The ability of the unit to cool in low speed is checked.
• Heat Check - The ability of the unit to heat in low speed is checked.
• Report Test Results - The test results are reported as PASS,
CHECK or FAIL when the Pretrip Test is completed. If test results are CHECK or FAIL alarm codes will exist to direct the technician to the source of the problem.
Pretrip Test Considerations
When performing a Pretrip Test, the following issues should be considered.
• If running a Pretrip Test on a truck or trailer loaded with dry cargo, insure that proper airflow can occur around the load. If the load restricts airflow, false test results may occur. Also, SR-3 units have high refrigeration capacity which results in rapid temperature changes. Sensitive dry cargo may be damaged as a result.
• If running a Pretrip Test on a truck or trailer that has just been washed down, the extremely high humidity inside the truck or trailer may result in false test results.
• If running a Pretrip Test on a truck or trailer loaded with sensitive cargo, monitor the load temperature during the test as normal temperature control is suspended during a
Pretrip Test.
• Always perform Pretrip Tests with the truck or trailer cargo doors closed to prevent false test failures.
90
Unit Operation
Performing a Pretrip Test
If a Pretrip Test is initiated with the engine shut down a Full
Pretrip Test will be performed. If a Pretrip Test is initiated with the engine or motor running a Running Pretrip Test is performed.
• Before initiating a Pretrip Test, clear all alarm codes.
• To stop a Pretrip Test at any time, turn the unit off. Alarm
Code 28 Pretrip Abort will be set. Other alarms may also be set, depending upon test in progress when the test was terminated.
.
Pretrip Tests are initiated using the Pretrip Menu. From the
Standard Display, press the MENU key.
The Language Menu or Alarm Menu will appear. Press the
NEXT key as required to display the Pretrip Menu. When the
Pretrip Menu is shown press the SELECT key.
Figure 106: Select Key
If the unit is not running a Full Pretrip Test will be initiated. If the unit is running in either diesel or electric mode a Running
Pretrip will be performed.
Figure 105: Menu Key
Figure 107: Running Pretrip
91
Unit Operation
If all alarms were not cleared a prompt appears as shown in
Figure 108. Exit the Pretrip Test, clear all alarms and restart the
Pretrip Test.
Figure 108: No Pretrip Prompt
If no alarms are present, the Pretrip Test display appears.
• The top line of the display indicates the unit is performing the non-running portion of the Pretrip Test.
• The second line measures test progress. The number of tests completed of the total number of tests to be
performed is shown. In Figure 109 the unit is performing
Test 1 of 26, Sensor Check.
• The soft keys may be used during the Pretrip Test to select the Hourmeter, Gauge or Sensor menus.
• To stop a Pretrip Test at any time turn the unit off. This will generate Alarm Code 28 Pretrip Abort. Other alarm codes may also be generated. This is normal when the
Pretrip Test is halted before completion.
When the non-running tests are complete the unit will start automatically and continue with the Running Pretrip Test. In
the example in Figure 110 the unit is in the Running Pretrip
and is performing Test 21 of 26, Cool Test.
Figure 109: Pretrip Test Display
92
Unit Operation
Figure 110: Performing Cool Test
When all tests are complete, the results are reported as PASS,
CHECK or FAIL. If the results are CHECK or FAIL, the accompanying alarm codes will direct the technician to the cause of the problem.
Figure 111: Pass, Check or Fail
If the Pretrip Test results are CHECK or FAIL the problem should be diagnosed and corrected before the unit is released for service.
Diesel/Electric Menu
The Diesel Mode/Electric Standby menu allows the operator to manually select diesel or electric mode operation. The unit can also be programmed to automatically select electric mode operation when standby power is available and to automatically select diesel mode operation if standby power fails or is removed. If the unit is programmed to switch automatically from diesel to electric and electric to diesel these screens do not appear.
Switching from Diesel to Electric - Units equipped with the Electric Standby option only
If the Diesel to Electric Autoswitch Enabled feature in
Guarded Access is set YES then the unit will automatically switch to Electric Mode operation when standby power is connected and available.
93
Unit Operation
If the Diesel to Electric Autoswitch Enabled feature in
Guarded Access is set NO then the prompt screen shown in
Figure 112 will appear when standby power is connected and
available.
Figure 112: Standby Power connected & available
If YES is selected then the display will briefly show the screen
Switching from Electric to Diesel - Units equipped with the Electric Standby option only
If the Electric to Diesel Autoswitch Enabled feature in
Guarded Access is set YES then the unit will automatically switch to Diesel Mode operation when standby power is turned off or is no longer available.
If the Electric to Diesel Autoswitch Enabled feature in
Guarded Access is set NO then the prompt screen shown in
Figure 114 will appear when standby power is turned off or is
no longer available. Alarm Code 91 Check Electric Ready
Input and Alarm Code 84 Restart Null will both be set.
Figure 113: Display when YES is selected
Electric Mode operation will briefly be confirmed. If unit operation is required the electric motor will start as shown previously in STARTING THE ELECTRIC MOTOR.
94
Figure 114: Display when Standby Power not available
Unit Operation
Turn the unit off and back on using the OFF and ON Keys.
This will clear Alarm Code 91 Check Electric Ready Input and
Alarm Code 84 Restart Null. NOTE: The CLEAR Soft Key will not clear these two alarms. Then the prompt screen shown
Figure 115: Prompt for Switch to Diesel
If YES is selected then the display will briefly show the screen
in Figure 116. Then Diesel Mode operation will briefly be
confirmed.
Figure 116: Display when YES is selected
If unit operation is required the diesel engine will start as shown previously in STARTING THE DIESEL ENGINE.
Adjust Brightness
The brightness of the HMI Control Panel display can be adjusted to allow for changing ambient light conditions. The choices available to the operator are HIGH, MEDIUM, LOW and OFF. OFF actually results in a very dim screen suitable for low light conditions.
Display brightness is adjusted using the Adjust Brightness
Menu. From the Standard Display, press the MENU key.
95
.
Unit Operation
The Display Brightness menu will appear as shown below.
Press the + or - keys to select the desired display brightness.
When the desired brightness is shown press the YES key to confirm the choice.
Figure 117: Menu Key
The Language Menu or Alarm Menu will appear. Press the
NEXT key as required to display the Adjust Brightness Menu.
When the Adjust Brightness Menu is shown press the SELECT key.
Figure 119: + and - Keys
The display will briefly show ADJUSTING BRIGHTNESS -
PLEASE WAIT.
Figure 118: Select Key
Figure 120: Adjusting Brightness
The display brightness is changed to the new setting.
96
Time
.
The system time and date is viewed using the Main Menu.
Time and Date cannot be changed from the Main Menu. From the Standard Display, press the MENU key.
Figure 122: Select Key
The current time and date will appear.
Unit Operation
Figure 121: Menu Key
The Language Menu or Alarm Menu will appear. Press the
NEXT key as required to display the Time Menu. When the
Time Menu is shown press the SELECT key.
Figure 123: + and - Keys
97
Loading and Enroute Inspections
Thermo King refrigeration units are designed to maintain the required temperature for the product being carried during its time in transit. Because of the unit’s unique design, special care is required during loading to prevent cargo spoilage.
Pre-Loading Inspection
1.
Inspect all door seals, including vent doors, for condition and a tight seal with no air leakage.
2.
Inspect the cargo compartment inside and out for damaged or loose skin and insulation.
3.
Inspect the inside of the cargo compartment for damaged walls, air ducts, floor channels or “T” flooring, clogged defrost drain tubes, and clogged or damaged floor channels which could block the air return, creating isolated areas in the load that are warmer than the desired temperature.
4.
Pre-cool the cargo compartment. Adjust the setpoint to the desired cargo temperature and allow the unit to run a minimum of 30 to 60 minutes (longer if possible) before loading. Check to be certain the setpoint temperature is correct for the cargo.
Pre-cooling before loading will remove residual heat and moisture from the cargo compartment and prepare it to receive the refrigerated load. Pre-cooling also provides a good test of the refrigeration system.
5.
Make sure products are pre-cooled to the proper temperature before loading. Any variance should be noted on the manifest.
6.
Supervise product loading to make sure that there is sufficient air space around and through the load so air flow is not restricted.
98
Loading and Enroute Inspections
Inspecting the Load
Never assume that the product has been loaded properly. Watch for and perform the following tasks. It takes only a few minutes and could save you or your employer considerable time and money later on.
1.
Make sure the unit is off before opening the cargo compartment doors. During operation, the unit blows out refrigerated air, and draws in outside air.
NOTE: The unit can be run with the doors open if the truck is backed into a refrigerated warehouse with tight door seals.
2.
Perform a final check of the load temperature. If the load is too hot or too cold, make a final notation on the manifest.
CAUTION: Make sure cargo is pre-cooled to the proper temperature before loading. The unit is designed to maintain temperature, not cool an above-temperature load.
3.
While inspecting to see that the cargo is loaded properly, make sure the evaporator inlets and outlets are not blocked.
4.
Close or supervise the closing of the cargo compartment doors. Make sure they are securely locked.
5.
Check to make sure the unit setpoint is set at the desired temperature as listed on the manifest.
6.
If the unit was stopped, restart using the appropriate starting procedure outlined in this manual.
7.
Repeat the after-start inspection.
8.
Defrost the unit 30 minutes after loading by starting a manual defrost cycle.
99
Loading and Enroute Inspections
Enroute Inspections
NOTE: Enroute inspections are recommended every four hours for the prevention of damage to the cargo.
1.
Note the setpoint to make certain no one has altered the setting since picking up the load.
2.
Note the return air temperature reading. It should be within the desired temperature range. If the return air temperature reading is not within the desired temperature range, it indicates one of the following: a.
The unit has not had sufficient time to pull down the temperature. Refer to log, if possible, for history of load (for example, above temperature load, properly pre-cooled cargo compartment, length of time on road).
b.
The unit is in defrost or has just completed defrost.
NOTE: You can cancel defrost by turning the unit off, then restarting the unit. c.
The evaporator is plugged with frost. Initiate a manual defrost cycle. The defrost cycle will be automatically terminated. d.
Improper air circulation within the cargo compartment. Inspect the cargo compartment (if possible) to determine if the evaporator fans are working and properly circulating the air. Poor air circulation can be due to improper loading of the cargo or shifting of the load, or the fan belt slipping.
WARNING: The unit may START automatically AT
ANY TIME while it is turned ON. Make sure to turn the unit OFF before opening unit doors or inspecting any part of the unit.
e.
The unit did not start automatically. If the unit cranked without starting, determine and correct the cause for not starting.
100
Loading and Enroute Inspections f.
The unit may have a low refrigerant charge. If liquid is not showing in the unit receiver tank sight glass, the refrigerant charge may be low. Adding refrigerant or repairing the refrigeration system requires a competent mechanic. Refer such problems to the nearest Thermo King dealer or authorized Service
Center, or call the Thermo King Cold Line telephone number shown on the inside back cover of this manual for referral.
NOTE: If the temperature in the compartment is not within the desired temperature range, repeat the Enroute
Inspection every 30 minutes until the compartment temperature comes within the desired temperature range.
CAUTION: Stop the unit if the compartment temperature remains outside the desired temperature range from the setpoint on two consecutive 30 minute inspections. Contact the nearest Thermo King
Service Center or your company office immediately.
Take all necessary steps to protect and maintain proper load temperature.
3.
Initiate a Manual Defrost cycle after each Enroute
Inspection.
101
Specifications
Engine
Model:
Fuel Type
Oil Viscosity
T-680R, T-680S, T-880R & T-880S
T-1080R & T-1080S
TK374F (Tier 4)
TK380F (Tier 4)
No. 2 Diesel fuel under normal conditions
No. 1 Diesel fuel is acceptable cold weather fuel
Oil Capacity:T-680S and T-880S
Crankcase & Oil Filter
T-680S and T-880S w/Bypass Oil Filter
9.0 quarts (8.5 liters)
10.0 quarts (9.5 liters) Fill to full mark on dipstick
T-1080R & T-1080S Crankcase & Oil Filter
T-1080R & T-1080S w/Bypass Oil Filter
Oil Type
12.0 quarts (11.4 liters)
13.0 quarts (12.3 liters) Fill to full mark on dipstick
API Classification CI-4 or better
(ACEA Rating E3 or better for Europe)
14 F to 122 F (-10 C to 50 C): SAE 15W-40 (Synthetic)
5 to 104 F (-15 to 40 C): SAE 15W-40
-13 to 104 F (-25 to 40 C): SAE 10W-40
-13 to 86 F (-25 to 30 C): SAE 10W-30
-22 to 122 F (-30 to 50 C): SAE 5W-40 (Synthetic)
Below -22 F (-30 C): SAE 0W-30 (Synthetic)
102
Engine (Continued)
Engine rpm:
Engine Oil Pressure
Low Speed Operation 1625 ± 25 rpm
High Speed Operation Reciprocating Compressor: 2200 ± 25 rpm
Scroll Compressor: 2200 ± 25 rpm
20 to 50 psig (138 to 345 kPa) in low speed
40 to 60 psig (276 to 414 kPa) in high speed
0.006 to 0.010 in. (0.15 to 0.25 mm) Intake Valve Clearance
Exhaust Valve Clearance
Valve Setting Temperature
Fuel Injection Timing
Injection Nozzle Pressure
Low Oil Pressure Switch/Sensor
High Coolant Temperature Sensor
Engine Thermostat
0.006 to 0.010 in. (0.15 to 0.25 mm)
70 F (21 C)
16 ± 1 degrees BTDC
1784 to 1929 psig (12,300 to 13,300 kPa)
10 ± 2 psig (69 ± 14 kPa)—shutdown
220 ± 5 F (104 ± 3 C)—shutdown
160 F (71 C)
Specifications
103
Specifications
Engine (Continued)
Engine Coolant Type
ELC (Extended Life Coolant), which is “RED”
Use a 50/50 concentration of any of the following equivalents:
Chevron Dex-Cool
Texaco ELC
Havoline Dex-Cool®
Havoline XLC for Europe
Shell Dexcool®
Shell Rotella
Saturn/General Motors Dex-Cool®
Caterpillar ELC
Detroit Diesel POWERCOOL® Plus
CAUTION: Do not add “GREEN” or “BLUE-GREEN” conventional coolant to cooling systems using “RED”
Extended Life Coolant, except in an emergency. If conventional coolant is added to Extended Life Coolant, the coolant must be changed after 2 years instead of
5 years.
104
Specifications
Engine (Continued)
Units Built Prior to October 2016
Coolant System Capacity:
T-680R, T-680S, T-880R, T-880S
T-1080R, T-1080S
Coolant Expansion Tank Cap Pressure
Units Built After October 2016
Coolant System Capacity:
T-680R, T-680S, T-880R, T-880S
T-1080R, T-1080S
Coolant Expansion Tank Cap Pressure
Units with coolant expansion tank only
6.0 quarts (5.7 liters)
6.5 quarts (6.2 liters)
15 psig (103 kPa)
7 psig (48 kPa) after November 2015
Units with coolant expansion tank and overflow bottle
7.64 quarts (7.23 liters)
8.36 quarts (7.91 liters)
10 psig (69 kPa)
Belt Tension
Belt
Water Pump Belt
Engine/Electric Motor (Jackshaft) –
Static Belt Tensioner
Tension No. on TK Gauge
P/N 204-427
New Belt
40
81
Field Reset
40
77
Frequency Gauge P/N 204-1903
Setting Where Applicable
New Belt
62 Hz
Field Reset
55 Hz
Electric Motor (Jackshaft)/Compressor Automatically tensioned by tensioner position. See “Belts” in appropriate Maintenance Manual Chapter.
105
Specifications
Engine Clutch
Engagement
Dynamic Torque
600 ± 100 RPM
66 ft-lb (89.5 N•m) minimum @ 1600 RPM
Refrigeration System
Reciprocating Compressor
Unit Model: T-680R and T-880R
T-1080R
Refrigerant Charge: T-680R
T-880R
T-1080R
*Compressor Oil Charge:
X214 in T-680R and T-880R
X426 in T-1080R
Compressor Oil Type
Compressor Model:
Thermo King X214
Thermo King X426
8.0 lb (3.6 kg) R-404A
8.5 lb (3.9 kg) R-404A
9.0 lb (4.1 kg) R-404A
3.2 quarts (3.0 liters)
4.3 quarts (4.1 liters)
Ester base P/N 203-513 required
106
Specifications
Refrigeration System
Suction Pressure Regulator Valve Setting:
T-680R
T-880R
T-1080R
28 to 31 psig (193 to 214 kPa)
35 to 37 psig (241 to 255 kPa)
21 to 23 psig (145 to 159 kPa)
High Pressure Cutout Switch: Open
Close
470 ± 7 psig (3241 ± 48 kPa)
375 ± 38 psig (2586 ± 262 kPa)
* When the compressor is removed from the unit, oil level should be noted or the oil removed from the compressor should be measured. This is to be sure that the same amount of oil can be added before placing the replacement compressor in the unit.
Scroll Compressor
Unit Model:
Refrigerant Charge:
T-680S and T-880S
T-1080S
T-680S and T-880S
T-1080S
*Compressor Oil Charge
Compressor Model:
TK04 Scroll 4 HP
TK06 Scroll 6 HP
7.0 lb (3.2 kg) R-404A
7.5 lb (3.4 kg) R-404A
2.0 quarts (1.9 liters)
107
Specifications
Refrigeration System
Compressor Oil Type Ester base P/N 203-516 required for Scroll compressor
Discharge Pressure Regulator Valve Setting
High Pressure Cutout Switch: Open
Close
350 ± 5 psig (2413 ± 34 kPa)
470 ± 7 psig (3241 ± 48 kPa)
375 ± 38 psig (2586 ± 262 kPa)
* When the compressor is removed from the unit, oil level should be noted or the oil removed from the compressor should be measured. This is to be sure that the same amount of oil can be added before placing the replacement compressor in the unit.
Electrical Control System
Control System Voltage
Battery Charging System
12.5 Vdc
12 volt, 37 amp, brush type, Thermo King alternator
Voltage Regulator Setting 13.8 to 14.4 volts @ 77 F (25 C)
NOTE: Fuse F4 (Bypass resistor for Prestolite Alternator) must be removed for the Thermo King
Alternator.
108
Fuses
Fuse
F2
F3
F4
F10
F12
F13
F20
F21
F5
F6
F7
F8
F9
10A
5A
2A
2A
15A
2A
5A
5A
60A
Size
15A
40A
None
2A
40A
Specifications
Function
Power to On/Off Switch
Fuel Sol Pull-In/Starter Circuit
No Fuse - All Bosch and Thermo King Alternators
2A Fuse - All Prestolite Alternators
Preheat Circuit
Damper and High Speed Circuits
8XP Circuit - Controller On Feedback to HMI
2A Power to CAN Connector J12
2A Power to CAN Connector J14
8X Power (Install fuse in right position)
2A Power to CAN Connector J13
8FC Circuit (Remote Status Light/Optional Power)
Alternator Sense
Main Fuse (2 Circuit)
109
Specifications
Fuses (Continued)
Fuse Size Function
F25
F26
7.5A
5A
HPCO Switch Circuit
Power to CAN Connector J98
F4 Remove fuse F4 for units with Australian Bosch or Thermo King Alternators. Install fuse F4 for units with
Prestolite Alternator.
F10 When fuse F10 is installed in the right position the On/Off keys on the HMI turn the unit on and off. When fuse F10 is installed in the left position the unit will start and run without the HMI control panel.
Electrical Components
Component
Glow Plugs (3) Each
Fuel Solenoid:
High Speed (Throttle) Solenoid
Damper Solenoid
Pull In Coil
Hold In Coil
Current Draw (Amps) at 12.5 Vdc
4.3
35 to 45
0.5
3.3
5.7
Resistance
(Ohms)
2.3 ± 0.2
0.2 to 0.3
24 to 29
3.8
2.2
110
Electrical Components (Continued)
Component
Condenser Inlet Solenoid (CIS)
Hot Gas Solenoid (HGS)
Purge Valve (PV)
Liquid Injection Solenoid (LIS) (Scroll Compressor only)
Electronic Throttling Valve (ETV) if used:
Coil A (Red [EVA] and Blue [EVB] Wires)
Coil B (Black [EVC] and White [EVD] Wires)
Starter Motor (No Load Bench Test)
Current Draw (Amps) at 12.5 Vdc
1.8
1.1
1.1
1.1
—
—
90
Specifications
Resistance
(Ohms)
6.9
11.3
11.3
11.3
20 to 35
20 to 35
111
Specifications
SmartPower Electrical Standby (Model 50 Units Only)
T-680R, T-680S, T-880R, T-880S Electric Motor and Overload Relay
Voltage/Phase/Frequency Horsepower Kilowatts rpm
230/3/50
230/3/60
400/3/50
460/3/60
6.0
7.2
6.0
7.2
4.5
5.4
4.5
5.4
1460
1765
1460
1765
Full Load
(amps)
17.0
19.4
9.8
9.7
Overload Relay
Setting (amps)
19
22
11
11
T-1080R & T-1080S Electric Motor and Overload Relay
Voltage/Phase/Frequency Horsepower Kilowatts rpm
230/3/50
230/3/60
400/3/50
460/3/60
10.0
12.0
10.0
12.0
7.5
8.9
7.5
8.9
1460
1750
1460
1750
Full Load
(amps)
22.5
28.8
17.0
14.4
Overload Relay
Setting (amps)
25
32
16
16
112
Electric Heater Strips (Optional)
Number
Watts
Resistance
3
750 watts (each)
71 ohms (each)
SmartPower Standby Power Requirements
Supply Circuit Breaker:
T-680R, T-680S, T-880R & T-880S
230/3/60
T-1080R & T-1080S
230/3/60
All 380-460/3/50-60
Extension Cord Size:
30 amps
50 amps
20 amps
Up to 50 ft—10 gauge
75 ft—8 gauge
Specifications
113
Maintenance Inspection Schedule
A closely followed maintenance program will help to keep your Thermo King unit in top operating condition. The following general schedule is provided to assist in monitoring that maintenance.
For more specific detail, see the maintenance manual for your unit and to the PreTrip Inspection chapter in this manual.
Pretrip 1,200
Hours
2,000
Hours
Annual/
3,000
Hours
After first week of operation:
• Check belt tension.
• Tighten unit mounting bolts.
• Check coolant level.
• Check refrigerant oil level.
l
• Check refrigerant level.
Inspect/Service These Items
•
•
• •
Microprocessor
Run pretrip test (see “Pretrip Test” in Operating Instructions Chapter).
Engine
Check fuel supply.
Check engine oil level.
114
Maintenance Inspection Schedule
Pretrip 1,200
Hours
•
•
•
•
•
•
•
•
2,000
Hours
Annual/
3,000
Hours
•
•
•
•
•
•
•
•
•
Inspect/Service These Items
Check condition of belts.
Check engine oil pressure hot, on high speed.
Listen for unusual noises, vibrations, etc.
Check air cleaner hose for damage.
Inspect and clean electric fuel pump filter.
Dry air cleaner. Replace air cleaner element at 2,000 hours or 1 year
(whichever occurs first)
Change EMI 2000 (black) fuel filter.
Change engine oil and oil filters (hot). Requires oil with API Rating CI-4 or better (ACEA Rating E3 for Europe) and EMI 2000 bypass oil filter.
Check restraining mount (snubber) pre-load adjustment.
Drain water from fuel tank and check vent.
Check and adjust engine speeds (high and low speed).
Check condition of engine mounts.
115
Maintenance Inspection Schedule
Pretrip
•
1,200
Hours
2,000
Hours
Annual/
3,000
Hours
•
•
—
—
Inspect/Service These Items
Check coolant levels (cool)
Coolant Expansion Tank: The expansion tank must always be completely full of coolant when cool.
Coolant Overflow Bottle: Coolant level in overflow bottle must always be at or above the FULL COLD mark of the bottle when cool.
Maintain year round antifreeze protection at –30 F (–34 C).
Test fuel injection nozzles at least every 3,000 hours.*
Replace the fuel return lines between fuel injection nozzles every 10,000 hours or sooner as required.
Change ELC (red) engine coolant every 5 years or 12,000 hours. Units equipped with ELC have an ELC nameplate near the expansion tank.
* Based on EPA 40 CFR Part 89.
116
Maintenance Inspection Schedule
Pretrip 1,200
Hours
2,000
Hours
Annual/
3,000
Hours
Inspect/Service These Items
•
•
•
Electrical
Check controller for alarms.
Run pretrip test
Check battery voltage.
•
•
Inspect battery terminals and electrolyte level.
Inspect wire harness for damaged wires or connections.
•
•
Inspect alternator bearings and brushes.**
Inspect electric motor bearings (Model 50).**
** With belt removed, spin bearings by hand. Listen for noise (bearings roll freely).
117
Maintenance Inspection Schedule
Pretrip 1,200
Hours
• •
•
2,000
Hours
Annual/
3,000
Hours
•
•
•
—
Inspect/Service These Items
Refrigeration
Check refrigerant level.
Check compressor oil level.
Check suction pressure regulator setting on Defrost or Heat.
Check discharge and suction pressures.
Check compressor efficiency.
Replace dehydrator and compressor oil filter every two (2) years.
118
Maintenance Inspection Schedule
Pretrip 1,200
Hours
2,000
Hours
Annual/
3,000
Hours
Inspect/Service These Items
•
•
•
•
• •
Structural
Visually inspect unit for fluid leaks.
Visually inspect unit for damaged, loose or broken parts (includes air ducts and bulkheads).
Inspect clutch for shoe and anchor bushing wear with a mirror. Check bearings.**
•
•
Inspect idlers, fan shafts and jackshaft (if so equipped) for leakage and bearing wear.**
Clean entire unit including condenser coils, evaporator coils, and defrost drains.
• • • Check all unit, fuel tank, engine, and electric motor mounting bolts, brackets, lines, hoses, etc.
** With belt removed, spin bearings by hand. Listen for noise (bearings roll freely).
119
Warranty
Terms of the Thermo King Warranty are available on request.
Please reference document TK 50047 for the Thermo King
Self-Powered Truck Unit Warranty.
120
Serial Number and Refrigerant Label
Locations
Write the unit model and unit serial number in the spaces provided in the following Emergency Cold Line chapter. This information is needed to service the unit.
Figure 124: Engine Serial Number Location
Figure 125: Scroll Compressor Serial Number
Location,
121
Serial Number and Refrigerant Label Locations
Figure 126: X214 Reciprocating Compressor Serial
Number Location
AQA183
Figure 127: X426 Reciprocating Compressor Serial
Number Location
122
Serial Number and Refrigerant Label Locations
1
2
Figure 129: Laminated Unit Serial Number Plate
1.
Unit Serial Plate 2.
Refrigerant Type
Figure 128: Label Locations
Figure 130: Refrigerant Type Label
123
124
Recover Refrigerant
At Thermo King, we recognize the need to preserve the environment and limit the potential harm to the ozone layer that can result from allowing refrigerant to escape into the atmosphere.
We strictly adhere to a policy that promotes the recovery and limits the loss of refrigerant into the atmosphere.
In addition, service personnel must be aware of Federal regulations concerning the use of refrigerants and the certification of technicians.
For additional information on regulations and technician certification programs, contact your local THERMO KING dealer.
Emergency Cold Line
If you can’t get your rig rolling, and you have tried the Thermo
King North American Service Directory (available from any
Thermo King dealer) to reach a dealer without success, then call the Toll Free Emergency Cold Line Number
(888) 887-2202.
The answering service at the factory will assist you in reaching a dealer to get the help you need. The Cold Line is answered 24 hours a day by personnel who will do their best to get you quick service at an authorized Thermo King Dealer.
AMA1585
125
126
CALIFORNIA
Proposition 65 Warning
Diesel exhaust is a chemical known to the State of California to cause cancer.
Ingersoll Rand’s Climate Solutions sector delivers energy-effi cient HVACR solutions for customers globally. Its world class brands include Thermo King, the leader in transport temperature control and Trane, a provider of energy effi cient heating, ventilating and air conditioning systems, building and contracting services, parts support and advanced controls for commercial buildings and homes.
©2013 Ingersoll-Rand Company
Printed in U.S.A.
Ingersoll Rand’s Climate Solutions sector delivers energy-effi cient HVACR solutions for customers globally. Its world class brands include Thermo King, the leader in transport temperature control and Trane, a provider of energy effi cient heating, ventilating and air conditioning systems, building and contracting services, parts support and advanced controls for commercial buildings and homes.
©2013 Ingersoll-Rand Company
Printed in U.S.A.
Operator’s Manual
T-680R / T-880R / T-1080R
T-680S / T-880S / T-1080S
Series with
Premium SR-3 HMI
TK 55667-1-OP (Rev. 2, 09/16)
Operator’s Manual
T-680R / T-880R / T-1080R
T-680S / T-880S / T-1080S
Series with
Premium SR-3 HMI
TK 55667-1-OP (Rev. 2, 09/16)