Tender for Equipments 2016 - Maharaja Agrasen Medical College

Tender for Equipments 2016 - Maharaja Agrasen Medical College
DRAFT FOR APPROVAL
MAHARAJA AGRASEN MEDICAL COLLEGE,
AGROHA (HISAR) HARYANA-125 047
No. Tender/2016/Equipments
TENDER NOTICE
Tenders are invited for installation of Equipments in MAMC, Agroha, from the
Manufacturer/Distributors/suppliers. Tender form with terms & conditions can be obtained
from our college on payment of Rs. 2000/- Tender form may also be down loaded from the
college website, i.e., www.mamc.edu.in & submit with demand draft of Rs. 2000/- in favour
of Director, MAMC, Agroha.
Tenderer are required to submit security Rs. 1,00,000/- deposit in the name of
Director, M.A. Medical College, Agroha, failing which the tenders are liable to be rejected.
No interest will be paid on security deposit.
Last Date & Time for Submission of
Tenders
20/02/2016 upto 12:00Noon
Date & Time of opening of Technical Bids
20/02/2016 at 02:00PM
Date & Time of opening of Price Bids
24/02/2016 at 10:00AM
List of Equipments with specifications
Attached (Appendix -1)
If any of the above date are holiday the same will be extended to next working day.
Information is also available on
Website
E Mail
Phone No.
: www.mamc.edu.in
: mamc_agroha@yahoo.co.in, purchase@mamc.edu.in
: 01669281193,194 Ext 233
DIRECTOR
MAHARAJA AGRASEN MEDICAL
COLLEGE, AGROHA (HISAAR)
HARYANA
MAHARAJA AGRASEN MEDICAL COLLEGE,
AGROHA (HISAR) HARYANA
-----------------------------------------------------------------------------No. Tender/Equipments/2016/_____
Dated____/___/2016
Terms & Conditions
Tender for Equipments
(List of Equipments Appendix-1 Attached)
1.
2.
Tender received after schedule of date & time will not be accepted.
Tender shall be submitted in separate envelops for technical bid and
Price bid and both are submitted by the tenderer in a sealed envelop
which should reach this office on or before due date of submission.
3.
Technical Bid shall include Documenting evidence as necessary establishing that the
tenderer is eligible to submit the tender and qualified to perform the contract if its
tender is accepted.
4.
Technical Bid shall include documents and relevant details to establish that the goods
and allied services to be supplied by the tenderer conform to the
requirement/standard.
5.
Technical Bid shall include performance statements with relevant copy of orders and
end user satisfaction certificate.
6.
The price bid shall include make, model with minimum one year
guarantee/warrantee and five years AMC after guarantee/warrantee period.
7.
Comparative rate will be notified after preparation & approval of Technical
Committee.
8.
The rate shall be quoted as per item accompanying the tender form maintaining same
serial number as per our list, failing which tender may be rejected.
9.
Rates to be quoted inclusive of Excise Duty, CST/ Vat, transportation, insurance and
any incidental charges/ Tax on F.O.R. Destination basis including installation at
MAMC Hospital, Agroha for each item. No Taxes or any other charge will be paid
separately on quoted rates. There should be no overwriting in the rates quoted. The
rate quoted in price column should be for the unit and specification given. The
tenderer is strictly prohibited to change/alter specification or unit price quoted.
10.
The Firm shall quote the Comprehensive Maintenance Contract and Annual
Maintenance Contract for each equipments for five years after the guarantee/
warrantee period
11.
Tenderers are required to submit Earnest Money deposit Rs. 1,00,000/- (Rs. One Lac
only) in form of demand draft/FDR of any nationalized bank payables at Agroha
(hisar) in the name of the Director, MAMC, Agroha failing which the tender will be
rejected. Those who are exempted from depositing security are required to
submit a certificate from the competent authority. No interest will be paid on the
security deposit. The successful tenderers shall be required to deposit performance
security of the contract @ rate of 05% of the cost of each item, in the form of Call
Deposit Receipt pledged to the Director, MAMC, Agroha (Hisar).The earnest money
shall be adjustable towards security. This would be kept upto period of warranty.
12.
Tenderer must agree to abide by all the terms and conditions of the tender. Any
default or breach of contract or supply of goods not conforming to the standards shall
render the tender to be rejected / cancelled and forfeiture of Earnest money. Each
page of the tender must be numbered serially & must sign with rubber stamp on
every page of the tender.
13.
Tenders of firm/ manufactures will be rejected if the same is black listed by any
competent authority or is involved in any criminal proceeding pertaining to
manufacture, supply or due to any dispute pending before any count or legal
forum. A undertaking of negativity of the above shall have to be provided by the
tenderers.
14.
Amendment of Bidding Documents- At any time prior to the deadline for
submission of bids, the Medical Superintendent may, for any reason, whether at its
own initiative or in response to a clarification requested by a prospective bidder,
modify the bidding documents by amendment. All prospective bidders who have
received the bidding documents will be notified of the amendment in writing, which
will be binding on them. In order to allow prospective bidders reasonable time within
which to take the amendment into account in preparing their bids, the Purchaser, at its
discretion, may extend the deadline for the submission of bids. CONDITIONAL
BIDS WILL NOT BE ACCEPTED.
15.
Modifications and Withdrawal of Bids- The Bidder may modify or withdraw its bid
after the bid's submission, provided that written notice of the modification or
withdrawal is received by the Medical Superintendent prior to the deadline prescribed
for submission of bids. The Bidder's modification or withdrawal notice shall be
prepared, marked and dispatched in a sealed envelope. A withdrawal notice may also
be sent by Email or fax but followed by a signed confirmation copy, post marked not
later than the deadline for submission of bids. No bid may be modified subsequent to
the deadline for submission of bids. No bid may be withdrawn in the interval between
the deadline for submission of bids and the expiry of the period of bid validity
specified by the Bidder on the bid form. Withdrawal of a bid during this interval may
result in the Bidder's forfeiture of its EMD.
16.
Clarification of Bids- During evaluation of the bids, the purchaser may, at its
discretion, ask the Bidder for clarification of its bid. The request for clarification and
the response shall be in writing and no change in price or substance of the bid shall be
sought, offered or permitted. No Bidder shall contact the Superintendent on any
matter relating to its bid from the time of the bid opening to the time the contract is
awarded. If the Bidder wishes to bring additional information to the notice of the
Medical Superintendent it shall be in writing. Any effort by a Bidder to influence the
Medical Superintendent in its on bid evaluation, bid comparison or contract award
decisions may result in rejection of the Bidder’s bid.
17.
All purchase will be made by competent authority as per store purchase rules of the
state govt and their orders issued from time to time. Any order issued by higher
authority will be followed. Recommendation of the purchase committee of the
hospital will be followed. Invitation of tender does not mean any commitment to
make purchases of all or any item listed in the tender.
18.
Supplies of Item will have to be F.O.R. Medical College, Agroha. No extra charges
will be paid for local freight etc. In case of any breakage, theft or any loss to the
goods during transit the responsibility of the loss will be of supplying firm. Financial
loss if any will be recovered accordingly.
19.
All supplies will have to be made within stipulated period as mentioned in the order.
In case the firm fails to comply with the order, the order will stand cancelled. The
Medical superintendent will be empowered to make purchases from the next firm,
other firms or local market. The difference in the rates will be recovered from E.M.D.
or bills of the first approved firm.
20.
All supplies should be made by approved firm only, the material supplied by Sister
Concern will not be accepted.
21.
Any claim for hike in prices of the Equipments covered in the tender will not be
allowed during the tender period.
22.
Payment will be made by bank draft or banker cheque and bank commission thereof
will be borne by the firm. No advance payment will be made.
23.
The Director, Medical College reserves the right to accept or reject any or all tenders
without assigning any reason thereof in public interest. The tendering authority also
reserves the right to make any addition or alteration in the terms and condition of the
contract from time to time.
24.
For any legal recourse the judicial jurisdiction only shall in the courts of Hisar,
Haryana. The contract shall be governed by the Laws of India.
DIRECTOR
MAHARAJA AGRASEN MEDICAL
COLLEGE, AGROHA, (HISAAR)
HARYANA.
Specimen of forwarding letter
From,
______________________
______________________
To,
DIRECTOR
MAHARAJA AGRASEN MEDICAL COLLEGE ,
AGROHA (HISAR) HARYANA
Sir
I am submitting tender for supply of Instruments & equipments to your
institution, as invited vide tender No.__________ Date___/___/_______ published
in
_____________________news paper. I accept all the terms and condition
given in tender, I have not added any terms & condition.
Enclosures
1.
2.
3.
4.
5.
Signature of Tenderer
6.
Declaration
1.
I/We are citizen of India.
2.
I/We are competent to contract as per Indian contract act.
3.
4.
5.
6.
I/We are not debarred for supply of Items by any Institution /office of
Haryana state.
I/We will be responsible for losses made for supply of poor quality of
Items.
I have not added any terms & condition other than given in this tender,
even if any terms and condition are added then it should be treated as
cancelled.
I/We have not quoted lower rate than quoted in this tender in any
office, institution or organization in the Haryana state.
Date:____/____/_____ Place:Tenderer
E-Mail Address :
Phone No :
Mobile No :
Signature of
Name :
Address:
(Annexure-I)
INFORAMATION OF BIDDER
1.
Registered Name
: _________________________
2.
Address
: _________________________
Factory
_________________________
_________________________
Office
_________________________
_________________________
_________________________
3.
Telephone No.
: _________________________
_________________________
_________________________
4.
Email Address
: _________________________
5.
Bank Account No. & Branch
: _________________________
6.
TIN or PAN No.
: _________________________
7.
CST No.
: _________________________
8.
LST Number
: _________________________
9.
Service Tax No.
: _________________________
Signature with Rubber Stamp
Specimen of Declaration/Undertaking
(To be submitted in Letter Pad)
(Annexure-II)
DECLARATION
We …………………………………………… (Full Name)having its registered
office at …………………………………………….(full address), declare that we
have not quoted lower rates than that of quoted in this tender in any
institution excluding Taxes.
Signature with Rubber stamp
(Annexure-III)
UNDERTAKING
We …………………………………………… (Full Name)having its registered
office at …………………………………………….(full address), undertake that we
have submitted up to date return and had no dues of Central and State
Taxes.
Signature with Rubber stamp
(Annexure-IV)
UNDERTAKING
We ……………………………………………(Full Name) having its registered
office at …………………………………………….(full address), undertake that our
firm has neither has been blacklisted by any competent authority nor any
criminal
proceeding
pertaining
to
manufacture,
supply,
quality
of
manufacturing items or due to any dispute pending before any court or legal
forum.
Signature with Rubber stamp
Appendix-1
Maharaja Agrasen Medical College (Agroha)
List of Equipments/Instruments Required
Sr. No.
1
2
3
4
5
6
7
8
9
10
11
Name of Equipments with Specifications
Disarticulated Bone Sets Male & Female
Tissue Floatation Bath Chamber
Temperature Ambient to 70˚ with an accuracy of ± 2˚ C digital control size 3 lt
minimum
Operating Microscope
Straight, Ergonomic Head tiltable from 0˚ to 210˚, wf 10x/16mm with eye
guard, optional WF 12.5x/16mm, WF 16x16mm, WF20x/12mm, 0.4x0.6x,1.0x,
1.6x&2.5x, f=250, manual fine focus, optional, f=300mm, f=400mm,
motorized fine focus , 50WELD, Green& Yellows, 600 mm, 1200ENT carrier,
Assistant binocular attachment, beam splitter, iVu S5 5 MP integrated digital
camera module with on-device capture button and SD card. Digital & Analog
outpur through USB v2.0 & RCA ports, double beam splitter, 0-2100 inclinable
ergo tube with digital camera
Micrometer Drill with 30000 RPM with foot control with 2 lock pieces
Temporal Bone Holder
Cutting Diamond Burrs of Variable sizes (10 Sizes)
Cabinet for Slides (1000) Wooden
Hot Air Cover for Drying Slides
(45oc) Thermostat to control surface temperature from ambient to 700c Size
600x200mm approx. digital control panel
Microwave – Hot Air Oven
Thermostat digital 94oC. Microwave capacity – 30 lts., Microwave Typeconvection and grill, Cavity Type- Anti Bacteria Cavity, Programme Panelfeather Touch, Minimum Turntable Diameter (mm)- 284, Power Output
(Watts)- 800, Power Consumption for Microwave(Watts)- 1100, Minimum
Clearance(Sides) (Inches)-2.
Electrophoresis Power Jet System Horizontal
Run. Mini-plus horizontal gel unit with removable casting tray and 2 x 1 mm
thick, 16- sample combs and coloured loading strips
Technical Specification
Unit Dimensions (Wx L x H) - 16.5 x 23 x 6.5 cm
Gel Dimension (W x L) - 10 x 11.5 cm
Buffer Volume - 450 ml
Maximum Sample Capacity - 80 Combs - 2
Comb Thickness - 1, 1.5 or 2 mm
Comb Throughput - 4 to 20 samples
Comb Slots - 4
Migration Distance Between Comb slots - 2.5 cm
Recommended Running Voltage - 75 to 125 V
Power Output Connectors (diameter) - Shrouded, 4mm
Electrophoresis Power Jet System Vertical
1|Page
Qty.
30
1
1
1
5 Set
1 Set
3
1
1
1
1
12
13
14
Run. 25 cm (L) x19cm(B)x20cm(H)
No. of samples:13
Buffer volume:300 ml (including upper and lower tanks)
Complete unit consists of
Basic unit with platinum electrode.
Glass plates notched & rectangular to run 16x14cm gel (2sets)
13-well polished Teflon comb with thickness of 1 mm and 1.5mm( 1 no. each) ( Well
width=6mm , Interspace=4 mm)
Teflon spacers with thickness of 1 mm & 1.5 mm (3 nos. each)
Gel casting stand (1 no.) Supporting clamp (1no.)
Screws (12no.) and metal clips (4nos.) Power cord with lid (1 no. each)User manual
Electronic Balance- Analytical Capacity 200gms and Sensitivity 1/10mg
B.O.D. Incubator
B.O.D. Incubator with reliable solid state temperature controller cum
indicator digital display, range from 5°C to 50°C ± 0.5°C. Hermetically sealed,
high performance compressor works efficiently to lower the inside chamber
temperature. Heating elements are placed in the path of moving air duly
insulated from the body. Cooling coils also lie in the air circulation path. Air is
circulated by a double shaft self-cooled, blower to keep the temp. uniform
throughout the inner chamber. A safety thermostat is provided, which
switches off the heaters in the event of failure of the normal temp. control
system to protect the specimens from excessive heat. Also fitted with a door
operated lamp for illumination inside the chamber. Should have Caster wheel
provided at bottom for easy mobility. Automatic cyclic timer 0–24 hrs.
regulating illumination cycle.
Product should be from CE & ISO 9001 certified companies.
W × H × D Cap. Cu. ft.
500 × 800 × 415 mm 6.1
Image Analyser
Research Microscope with facility for florescent microscopy and multiple
heads & software (imported) Microscope (one) : should have the necessary
components or accessories required for DIC/Fluorescence/ Bright field
applications. Fully apochromatic corrected optical path for fluorescence.
Neutral density filters for both bright field and Fluorescence Transmitted
light with built-in stabilized power supply ,Halogen lamp12V-100W Three Step
focusing. - 6 fold objective reversed nosepiece. - Trinocular tube with 25/30
degree viewing angle and three way beam splitting with 100:0/20:80/0:100 mechanical stage with ultra hard ceramic stage plate and coaxial drive. Eyepiece 10x/25, focusable. - Objectives Plan fluor 4/5x, 10x, 20x(for
BF,fluoroscence), 40x,and 100x (Oil) (for BF,DIC,fluoroscence). - Height
Adjustable focus knobs, torque adjustment. - Should have capability to
change the stage control knob assembly from left to right side or vice versa by
the user. - Fluorescence with pre centered mercury illumination having a life
span of at least 2000 hrs with . Fluorescence Attachment : 6- position
motorized fluorescence filter Turret for FISH and mFISH filters. 120/130W
Mercury Light illuminator with 2000hrs life time. FILTER FOR fluorescence
:DAPI/ Hoechst, Exciter 330-380, DM 400, BA 420 (UV) ,FITC/GFP,( Auramine
2|Page
1
1
1
15
O, Acridine- Orange) Exciter 450-490, DM505, BA 520 (Blue) ,TRITC, [Rhoda
mine& Texas Red dyes] Exciter 510-560, DM 575, Ba590 (Green)
Digital camera, Monochrome with 2/3 oblique 3 inch CCD chip of 1.4 MP
resolution should have peltier cooling 10 Deg. Below ambient. Pixel size of
6.45x6.45 Micro m. Camera should be from same manufacturer. A suitable
operating system with at least, Intel Core i7processor 8 GB DDR 3 RAM,
Firewire B port with UPS. 500GB HDD, DVR R/ W, TFT/LED 22” Monitor,
Graphics Card with 2 GB RAM, Gigabyte Ethernet, Key board, Optical mouse
and speakers 2.1 channel.etc. Instrument should be upgradable to motorized
system.
The following certificates have to be submitted:Industries certificate are as a proof of genuine/ original manufacturer
Authorization certificate from original manufacturer CE/ISO – 14001 & ISO
9001 certificate
Laminar Flow
with UV light. Work Area Dimensions (D x W) : 487 mm x 1869 mm
External Dimensions (W x D x H) : 1950mm x 640mm x 1300mm
Internal Work Area (W x D x H) : 1950mm x 640mm x 2160mm
Laminar Airflow Velocity : Average of 0.36 m/s or 70 fpm (+/-10%)
Filter Efficiency : Minimum: 99.9991% at 0.3µm / 99.9985% at O.12 µm / 99.9982%
at MPPS
Typical: 99.9998% at 0.3 µm / 99.9998% at O.12 µm / 99.9997% at MPPS
Pre-Filter: Disposable and non-washable polyester fibers with 85% arrestance / EU3
rated
Electrical : 220V, 50/60Hz
Heating system : Smart power injection electrical heating, 9 + 1 zones
Temperature Accuracy : ±0.2°C
Temperature Uniformity : ±0.2°C
Included advanced features : Integrated humidification system HS-1
: Surveillance system with data logger
: AIO PC
: Heated glass stage
: Transmitted light source SC-1 (with bulb)
: 5 x PTlOOO validation ports
Included Accessories : 1 x water bottle for HS-1, includes tubing
: 1 x sample carry tray
: 1 x humidif ied gas plastic cover
Microscope provision : Included for 1 microscope
Advanced Multi-Zone heated table plate (9+1 zones)
Surveillance system running data logger software
Touchscreen monitor (AIO PC)
Provision for integration of most common microscopes
Integrated heated glass stage
Integrated transmitted light source with dual-sided mirror and intensity control
knobs
PT1000 temperature validation ports
Humidification system with digital flow control of pre-mixed gas
Vertical laminar airflow providing sample protection
Low noise
Low vibration resulting from built-in dampers
3|Page
1
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
Selection of cabinet support stands
Selection between 4ft and 6ft models
Ph Meter
Bench top PH meter UB-5:Ph/temperature,
- Simple one button standerization with ph range 0.00-14.00.
- Auto buffer recoganization from 3 sets of 16 buffers, resolution 0.001 ph,
accuracy 0.005 ph,
- Automatic temperature compensation and temperature range 0.0-100 C ,
- Resolution 0.1 C, Accuracy 0.2 C,
Direct potentiometric measurement and incremental modes, Date & time
stamp, non-volatile memory
Centrifuge
20000 RPM, 1 to 99 minutes Timer, LCD display,
Max Capacity minimum 400 ml, capacity range -0.2 ml to 100ml. RCF
approximate 34000xg. 24x2/1.5 ml angle rotor with sterlizeable epoxy coated
and lid Ependorff tubes.
Product should be from CE & ISO 9001 certified companies.
Autoclave
High pressure electrically heated vertical steam sterilizer used for sterilizing of
surgical instruments, dressing material, linen, rubber, plastic material,
injection liquids by means of steam under pressure of 15 to 20 psi.
(adjustable). Outer chamber made of thick stainless steel sheet. Lid is made of
thick stainless steel plate single piece. Joint less neoprene gasket without any
leakage.
Fitted with double safety valve, water level indicator, water inlet and drain
valves. Supplied complete with cord and plug.
Product should be from CE & ISO 9001 certified also ISI certified companies.
Size:- 375 × 275 mm (15" × 11") minimum
Parallelograph (Martin Type)
Verificator Measuring Range 10-250m
Orbitometer GPM Swiss Made
Spherometer with a Brass Dial Head of about 40mm Diameter Divided in
Hundred Parts and Three Steel Legs with Vertical Scale of 10-0-10
Diaptrograph (Martin Type) Rectangular
Blood Bank Refrigerator Specifications as per Annexure “A” attached
Refrigerated Centrifuge Machine Specifications as per Annexure “B” attached
Blood Bag Transport Box Specifications as per Annexure “C” attached
REAL TIME PCR Specifications as per Annexure “D” attached
Semi Auto Analyzer Specifications as per Annexure “E” attached
Refrigerated Centrifuge Specifications as per Annexure “F” attached
HPLC Specifications as per Annexure “G” attached
Elisa Reader with Washer and Printer Specifications as per Annexure “H”
attached
Research Trinocular Microscope with Camera Specifications as per Annexure
“I” attached
Electrolyte Analyzer Specifications as per Annexure “J” attached
4|Page
1
1
1
1
1
1
1
1
1
1
4
1
1
1
1
1
1
1
34
35
36
37
38
ECG Machine Specifications as per Annexure “K” attached
Treadmil Specifications as per Annexure “L” attached
Spriometer Specifications as per Annexure “M” attached
Semi Automatic Analyzer Specifications as per Annexure “N” attached
ECG 03 CHANNEL (Three Channel ECG Machine with Graphical Display)
39
PC Based Spiro Meter
40
41
42
43
1
1
1
2
12 lead simultaneous acquisition
Graphical colored TFT for Real time ECG monitoring
Measurements and interpretation
Full alphanumeric keypad
Paper out indication
Multiple printing options
Isolation protection against defibrillation
20 patient memory storage
USB storage (optional)
Direct A4 ECG printing (optional)
PC connectivity (optional)
USB powered ergonomic handset
Detachable and easy to disinfect digital turbine transducer
Best maneuver selection (Auto/Manual)
FVC, SVC and MVV test
Indian predicated equations
Ethnic corrections
Pediatric incentives
Lungs age calculation
Flow-volume/volume-time graphs
Pre-post bronchodialation test
Trends
Doctors notes
Auto-interpretation
Customized printing options (single and all curves)
(With PC and Printer)
Tread Mill (12 Lead Stress test System)
PC based cardiac workstation combines resting and exercise ECG
Simultaneous acquisition and display of 12 lead raw ECG
Standard and user programmable treadmill protocols
Risk prediction duke tread mill score
Detection of lead and arrhythmias
User configured multiple display and report format
Heavy duty tread mill
Upgradeable to automatic NIBP (optional)
(With PC and Printer)
Histamine Chamber Complete with sphygmomanometer & nebulizer
Cook’s pole climbing apparatus
1
1
Continuous avoidance response (C.A.R) apparatus
1
New imported model with built in solid state buzzer and stimulator to provide
electrical shocks of 400v in pulsating rates 0.2 ma a frequency of 5 per sec for a
duration controlled manually or by built in 30 second timer output available for
recording on kymograph or polygraph complete to work on 220V A.C for the study of
pole jump (avoidance ) response
5|Page
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
Digital / Microprocessor Controlled.
Jumping Box Voltage Control model
Y –maze Simple- Semi Automatic
T –maze Simple- Semi Automatic
Audiogenic Test Chamber With electro mechanical sound generator & Timer
Photoactometer
Improved digital and solid state type with six photo cells for measuring spontaneous
or induced activity with digital totalizer or counter
Rota Rod apparatus Standard model, microprocessor Control with Six
Compartments
1
1
1
1
1
1
Swimming Test apparatus
1
Hand Stabilimeter
1
Student Physiograph
1
Spectrophotometer
1
Penta Head Microscope Specifications as per Annexure “O” attached
ESR Analyzer Specifications as per Annexure “O” attached
Centrifuge Machine R8C Specifications as per Annexure “O” attached
Binocular Microscope Specifications as per Annexure “O” attached
Micro slide Cabinet Specifications as per Annexure “O” attached
Bio- safety cabinet-Type 2 Specifications as per Annexure “P” attached
Table Top Refrigerated centrifuge Specifications as per Annexure “Q”
attached
Lab Refrigerator
Bacteriology incubator Specifications as per Annexure “R” attached
Serum Inspissator Specifications as per Annexure “S” attached
Lab Refrigerator 40C
Hot air oven Specifications as per Annexure “T” attached
BOD Incubator Specifications as per Annexure “U” attached
Electrophoresis complete set Specifications as per Annexure “V” attached
Water bath Serology (56°C)Monocular Microscope
CO 2 incubator Specifications as per Annexure “W” attached
Deep Freezer (-70°C) Specifications as per Annexure “X” attached
Comparator, Nessler for water testing, Comparator 705 Housing , Nesslerizer
711-A1 body, 2x Nessler Tubes (250mm) with plungers, Nessler Illuminator
1
1
3
11
2
2
1
With single chamber & 4 digit electronic display
Digital, microprocessor controlled with timer & error counter
Digital with single channel & standard accessories for human & animal studies
Digital spectrophotometer range 340 to 960 nm with facility for automatic
concentration % transmission & O.D measurement Wavelength resolution 5 nm 3 ½
digital LED display with round test tube
1
2
1
1
2
1
1
1
3
1
1
1
Director
MAMC, Agroha
6|Page
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project