Simatic Manager Step 7 Profibus/Profinet Installation Guide

Simatic Manager Step 7 Profibus/Profinet Installation Guide
GUIDE
Simatic Manager Step 7
Profibus/Profinet
Installation Guide
G1026
Published 12/20/2013
TABLE OF CONTENTS:
Table of Contents....................................................................................................................................................................................2
About This Guide....................................................................................................................................................................................3
Required Parts..........................................................................................................................................................................................3
Hardware.............................................................................................................................................................................................3
Software..............................................................................................................................................................................................3
Target Files..........................................................................................................................................................................................3
Setup..........................................................................................................................................................................................................4
Simatic Step 7 Setup.........................................................................................................................................................................4
Setting the rotary dials for Profibus...........................................................................................................................................6
Setting the dip switches for Profibus.........................................................................................................................................6
Setting the rotary dials for Profinet............................................................................................................................................7
3 Rotary Dials...............................................................................................................................................................................7
2 Rotary Dials...............................................................................................................................................................................7
Dip Switches................................................................................................................................................................................8
Setting the Ethernet address via the software.........................................................................................................................8
Web Configuration....................................................................................................................................................................8
Pactware........................................................................................................................................................................................8
IP Addressing...............................................................................................................................................................................9
Installing GSD/GSDML files in the hardware configuration.................................................................................................12
Adding a Profibus GSD/Profinet GSDML files to the Siemens Step 7 hardware.....................................................11
Adding a Profinet GSDML file to the Siemens Step 7 hardware....................................................................................11
List of Profibus GSD/Prodinet GSDML files...........................................................................................................................11
Adding a device onto Profibus/Profinet network....................................................................................................................13
Adding a Profibus device onto the network.........................................................................................................................16
Adding a Profinet device onto the network...........................................................................................................................20
TURCK Profibus Manuals...................................................................................................................................................................23
2
www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441
ABOUT THIS GUIDE
This manual is intended to supplement the Siemens Simatic Step 7 V5.5 SP3 documentation. This document will go
through a brief introduction on creating a project in the Simatic Software and then will focus on installing, configuring,
and troubleshooting Turck Profibus / Profinet devices.
REQUIRED PARTS
Hardware
• Siemens S7-315-2PN/DP
• Turck BL20-GW-DPV1
• Turck BL20-E-GW-EN
• Turck FGEN-XSG16-5001
Software
Simatic Manager Step 7 Software –- Current Version is V5.5 Turck GSD(ML) Files
Target Files
Target files are required for Turck Programmable Gateways. The only applicable gateway for Profibus is the
BL67-PG-DP. Turck Target Files
www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441
3
SETUP
Simatic Step 7 Setup
It is assumed that there is working knowledge of Siemens Simatic Manager Step 7 V5.5. If not, please refer to the Siemens
Simatic Programming with Step 7 Manual.
Create a New project in Simatic Manager using New or New Project Wizard or Open an existing project from
File -> New
Add a station to the Step 7 Project; click Insert -> Station -> Simatic 300 Station.
In the example, it will be the Simatic 300 Station (S7-315-2PN/DP)
4
www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441
The Profibus Configuration is done in the Hardware Configuration. To set the PG/PC interface click
Options -> Set PG/PC Interface.
To add the Profinet Controller, right click on the slot the Profinet card is in the chassis and in the pop up window click
Add Module
To set the communication protocol, use the PG/PC Interface dialog to select the connection between the S7 PLC and the
PC. Most of the time TCP/IP (Auto) will be OK for communication between PLC and PC.
www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441
5
Setting the rotary dials for Profibus
There are two rotary dials on the BL20, BL67, BLCDP, FGDP. The left rotary dial is the high byte (0..F). The right rotary
dial is the low byte (0..F). Available addresses for the Profibus Network are 1..125. Field bus address 0, 126, 127
are not available for addressing.
Setting the dip switches for Profibus
The BL20-E-GW uses Dip Switches instead of the Rotary Dials. The Gateway’s bus address results from the addition of
valences (20 to 26) of the switched DIP-switches (position = 1)
The BL20-E-GW-DP allows the Activation of the Resistor RT using the last to Dip Switches. Both Switches must be set to
“On” to activate the Profibus Resistor
6
www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441
Setting the rotary dials for Profinet
Depending on the Turck Product being used there are either 2 or 3 rotary dials on the gateway. The dial is used to set
the last Octet of the IP address (x.x.x.1-254). The first three octets will be set through the internet explorer or Pactware
or the Turck IP Address tool.
3 Rotary Dials
2 Rotary Dials
Field Transmission Rate
Fieldbus addressing range
Fieldbus addressing
Fieldbus connection technology
10/100 Mdps
1...92
0 (192. 168. 1.254)
93 (BootP)
94 (DHCP)
95 (PGM)
96...99 (Vendor Specific)
2 decimally coded rotary switches
2 x M12, 4-pin, d-coded
www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441
7
Dip Switches
Address-switches
20-27 (Value)
CFF
MODE
Name
0
OFF
OFF
Restore
1-254
OFF
OFF
Address
1
OFF
ON
DHCP
2
OFF
ON
BOOTP
4
OFF
ON
PGM
8
OFF
ON
PGM-DHCP
16
OFF
-
-
32
OFF
ON
F_Reset
Setting the Ethernet address via the software
Web Configuration
To configure the IP Address using the Web Configuration, open Internet Explorer and Type in the IP address of the
gateway you are connecting to.
Pactware
Pactware is a useful troubleshooting, simulating and monitoring tool for Turck gateways and I/O attached to the
gateway. If Pactware is not installed, click to direct you to the Pactware I/O Assistant Software. Click on the Full to
download Pactware to your computer.
With the Turck gateways connected, open the Pactware software. It will bring the dialog box up to select Hart Modem,
Turck BL Service RS232, or Turck BL Service TCP-IP. Select Turck BL Service TCP-IP
Once selected, it will add the Ethernet driver to the Project Side in Pactware. Double Click on TCP/IP to open the
BusAddress Management screen.
8
www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441
Click on the Eye in the Bus address Management screen to search for available gateways on the network. Once all the
Turck devices on the network have been found, click on the Add Device/DTM to project (The battery with a plus sign).
This will add the Device to the Project window. Also, it will add all I/O attached to the Gateway to the project window
for simulating and monitoring.
IP Addressing
In Turck products, the IP addressing can be set by either connecting to the Turck Gateway through Pactware, the IP
address tool, or through Internet Explorer or modifying the first three octets of the IP Address. The last octet will be set
by the rotary dials or dip switches.
To set the IP address in Step 7
1.Open either SIMATIC Manager or Hardware Configuration Manager
2.In SIMATIC Manager, Click PLC –> Edit Ethernet Node
www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441
9
3.In HW Config., Click PLC -> Ethernet Node -> Edit Ethernet Node
4.Click the Browse button. This will bring up a list of all available Profinet Nodes
10
www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441
5.Select the Profinet node to modify.
6.Click OK
7.Once a node is selected, the IP address, Subnet, and Device Name will all be available to be modified. With Profinet, the
Siemens PLC relies on the Device name to establish communications with the device on the network.
Once the name and IP address has been assigned to the Device, click Close
www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441
11
INSTALLING GSD / GSDML FILES IN THE HARDWARE CONFIGURATION
1.Open the Hardware Configuration Manager window and close all open projects.
2.Click Options – Install GSD File…
3.Browse to the folder where the GSD file is located.
4.Select file(s). Click “Install”.
Note: All files with .GSD are the default GSD files in the English language. Other versions may include GSE
(English), GSF (French), and GSG (German) languages.
All Profinet files are .XML files.
12
www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441
ADDING A DEVICE ONTO PROFIBUS / PROFINET NETWORK
Depending on the PLC defined in the configuration, there may be multiple Profinet or Profibus Nodes. In this example,
only one Profibus and one Profinet node is used. It is assumed the PLC has been defined in the hard-ware configuration.
1.Open Hardware configuration from SIMATIC ManagerTo add a Profibus network, left double click on the MPI/DP address and
change the interface type from MPI to Profibus,
2.Click Properties…
www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441
13
3.Add a New Subnet to the Profibus Network
4.Click OK -> OK -> OK to exit out of Profibus interface parameters
5.For Profinet, double click on PN-IO in the Siemens PLC rack.
14
www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441
6.On the General tab, Click on Properties button
7.In the Properties window, click “New” to create a new Profinet network. On the
Properties page, the IP address and subnet can be changed.
8.Click OK -> OK -> OK
www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441
15
9.Right mouse click on PN-IO. Click Insert Profinet IO System. This will create the Profinet
network allowing devices to be added onto the configuration.
Adding a Profibus Device
To add a Profibus device, open the Hardware Configuration (HW Config). On the right side of the HW Config window the
Profibus, Profinet, and Simatic 300/400 station GSD files are stored in a Library.
1.Open Hardware configuration from SIMATIC Manager
16
www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441
2.To add a Turck Profibus device, Select from the folder tree in the library - Profibus DP -> Additional Field
Devices -> I/O -> Turck. This will show all Turck Profibus devices that have been added to the library.
3.After selecting a device from the folder left click on the device (ie BL20-GW-DPV1) and
drag it into configuration window onto the Profibus DP Master system.
www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441
17
4.Once the device is on the Profibus network, double click on the BL20 to display the properties where the Profibus Node
address and Parameters can be modified.
5.After adding the device to the network, the I/O associated device will be added to the system. Left click on the I/O slices
and drag them into the I/O configuration window with the Slots / DP ID / Order Number / I addresses / Q addresses.
Note: the I/Q addresses are automatically assigned but can be changed from the Parameters on each slice.
18
www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441
6.Left click on the individual slice to bring up the properties window.
7.The first window is to assign the I/O addresses in the HW Config. The PLC will check to verify the
length and make sure the length of Input / Output data does not overlap with other cards
www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441
19
Adding a Profinet Device
1.To add a Profinet device, open the HW Config. On the right side of the HW Config window the Profibus, Profinet, and
Simatic 300/400 station GSD files are stored in a Library.
To add a Turck Profinet device, Select from the folder tree in the library –
Profinet IO -> Additional Field Devices -> I/O -> Turck. This will show all Turck
Profinet devices that have been added to the library.
2.After selecting a device from the folder left click on the device (ie BL20-GW-EN-PN) and drag it onto the Profinet Network in
the configuration window.
3.Once the device is on the Profinet network, double click on the BL20-GW-EN-PN to display the properties where
the ProfiNet Device name and number can be modified. The Device Name must match the name that is assigned
to the device. It is case sensitive. There is also the area to modify the IP Address.
20
www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441
4.The Parameters of the BL20 gateway are located under Slot 0. To modify the Parameters, double click on the
gateway and click the Paramters tab. These are specific to the gateway.
5.After adding the device to the network, the I/O associated device will be added to the system. Left click on the
I/O slices and drag them into the lower window with the Slots / DP ID / Order Number / I addresses / Q addresses.
Note: the I/Q addresses are automatically assigned but can be changed from the Parameters on each slice.
www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441
21
6.Double click on the individual slice to bring up the properties window. The I/O address is available for changing in
the second tab and the Parameter Assignments are on the third tab.
22
www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441
TURCK PROFIBUS / PROFINET MANUALS
Profibus
BL67-PG-DP
http://www.turck-usa.com/illustrations/M6827240%20(sheet_2).pdf
BL67-GW-DPV1
http://www.turck-usa.com/illustrations/M6827232%20(sheet_2).pdf
BL20-GW-DPV1
http://www.turck-usa.com/illustrations/M6827234%20(sheet_2).pdf
BL20-E-GW-DP
http://www.turck-usa.com/illustrations/M6827250%20(sheet_2).pdf
Profinet
BL67-GW-EN
http://www.turck-usa.com/illustrations/M6827228%20(sheet_2).pdf
BL20-GW-EN
http://www.turck-usa.com/illustrations/M6827300%20(sheet_2).pdf
BL20-E-GW-EN
http://www.turck-usa.com/illustrations/M6827329%20(sheet_2).pdf
FXEN*
http://www.turck-usa.com/illustrations/D301136_FXEN_PROFINET_GB_0508.pdf
www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441
23