3onedata IMC101GT Industrial gigabit Ethernet media converter User manual

3onedata IMC101GT Industrial gigabit Ethernet media converter User manual

Below you will find brief information for Industrial gigabit Ethernet media converter IMC101GT. IMC101GT is an industrial gigabit media converter, supporting 1 10Base-T/100Base-TX/1000 Base-TX port and 1 1000Base-X SFP port. It has LFP function, making it easy to check the network connection status. The IMC101GT has IP40 protection, a rugged high-strength metal case, a power supply input of 12V~48VDC, and a working temperature of -40 to 85°C.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

IMC101GT User Manual - Industrial Gigabit Ethernet Media Converter | Manualzz

IMC101GT

Industrial gigabit Ethernet

Media converter

User manual

Shenzhen 3onedata Technology Co.,Ltd

Tel: +86-755-26702668 Fax: +86-755-26703485 www.3onedata.com

Introduction

IMC101GT is a kind of industrial gigabit media converter, it support 1 10Base-T/100Base-TX/1000 Base-TX port and 1

1000Base-X SFP port. It support LFP function, it is easy to check the network connection status,, it also support CE,FCC standard, IMC101GT adopt industry standard design, IP40 protection, rugged high-strength metal case, power supply input(12V~48VDC), -40 to 85°C working temperature.

Packing list

Please check the package and all the components inside are in good condition before you use the switch.

IMC101GT x1

User manual x1

Warranty card x1

DIN rail x1

The equipment built-in precision devices, please note gently, avoiding excessive vibration to avoid affecting device performance. If you find the equipment was damaged in transit or any parts are missing, please inform our company or the dealer, we will give you proper solution as soon as possible.

Features

Support 1 port 10/100/1000 Base-TX and 1 port

1000Base-X SFP

Support IEEE802.3/802.3u/802.3x/802.3z store and forward

Ethernet port support 10/100/1000M self-adaption

Support LFP(Link Fault Pass-Through)

DC12~48V power input

IP40 protect grade, high strength iron shell, DIN Rail installation.

Panel Layout

1. PWR power input (3 bots terminal block)

2. Working status indicator

3. Fiber port connection indicator

4. Remote fiber port alarm indicator

5. 1000Base-X SFP port

6. 10Base-T/100Base-TX/1000 Base-TX port

7. Ethernet port connection indicator

8. Remote Ethernet port alarm indicator

9. Company name and Product name label

10. DIN-Rail

11. Grounding screw

Unit (mm)

Power Input

12~48VDC

IMC101GT provides 3 bits terminal block (V-, FG, V+), V-,

V+ is 12VDC ~ 48VDC power input. It can also work if connection opposite.

Communication Interface

10Base-T/100Base-TX/1000 Base-TX Ethernet port

10Base-T/100Base-TX/1000 Base-TX Ethernet port use in front panel, It is RJ45 port, the PIN define of RJ45 is as follows: connection adopt UTP or STP, the distance is no more

than 100m, 1000Mbps use cat5e, 100Mbps use cat5, 10Mbos use cat3,4, 5.

RJ45 port support MDI/MDI-X self-adaption. In (MDI),

PIN1, 2, 3, 4, 5, 6, 7, 8 connect corresponding, in (MDI-X)

PIN1→3, 2→6, 3→1, 6→2, 4→7, 5→8, 7→4, 8→5. In

MDI/MDI-X, 1000 Base-TX PIN define is as follows:

1 8

6

7

8

4

5

2

3

PIN

1

MDI MDI-X

BI_DA+/TX+ BI_DB+/RX+

BI_DA-/TXBI_DB-/RX-

BI_DB+/RX+ BI_DA+/TX+

BI_DC+/—

BI_DC-/—

BI_DD+/—

BI_DD-/—

BI_DB-/RXBI_DA-/TX-

BI_DD+/— BI_DC+/—

BI_DD-/— BI_DC-/—

Note : 10Base-T/100Base-TX , “TX±”transmit data±, “RX±”receive data±,

“—”not use.

MDI:

MDI-X:

1000Base-X SFP fiber port

1000Base-X fiber port is SFP multi mode or single mode port, it supports LFP.

Suggestion: please make a mark for your optic fiber

(Picture as follows: A-A, B-B or A1-A2, B1-B2) Easy to use

LED Indicator

LED indicator in front panel of IMC101GT monitor working status, the function of each LED is described in the table as below.

LED

RUN

LINK(G1)

LINK(G2)

LFP(G1)

LFP(G2)

System indication LED

State Description

ON/OFF Switch is unwonted

Blinking Switch is active

ON

Blinking

OFF

ON

OFF

ON

OFF

ON

OFF

Local Ethernet port connection regular.

Local Ethernet port connection active

Local Ethernet port had no connection.

Local Fiber port connection regular and active.

Local fiber port had no connection.

Remote Ethernet port had no connection or unwonted

Remote Ethernet port connection regular.

Remote fiber port had no connection or unwonted

Remote fiber port connection regular.

Installation

Before installation, confirm that the work environment meet the installation require, including the power needs and abundant space. Whether it is close to the connection equipment and other equipments are prepared or not.

Installation require as below

1. Avoid in the sunshine, keep away from the heat fountainhead or the area where in intense EMI.

2. Examine the cables and plugs that installation requirements.

3.Examine whether the cables be seemly or not (less than 100m) according to reasonable scheme.

4. Screw, nut, tools provide by yourselves.

5.Power need: power inputs(12~48DC)

6. Environment: -40°C to 85°C

Storage Temperature: -40°C to 85°C

Relative humidity 10% to 95%

DIN-Rail Installation

In order to use in industrial environments expediently, IMC101G adopt 35mm DIN-Rail installation, the installation steps as fellows:

1. Examine the DIN-Rail attachment

2. Examine DIN Rail whether be firm and the position be suitability or not.

3. Insert the top of the DIN-Rail into the slot just below the stiff metal spring.

4. The DIN-Rail attachment unit will snap into place as shown below.

Wiring Requirements

Wiring need to meet the following requirements:

It is needed to check whether the type, quantity and specification of cable match the requirement before cable laying;

It is needed to check the cable is damaged or not, factory records and quality assurance booklet before cable

laying;

The required cable specification, quantity, direction and laying position need to match construction requirements, and cable length depends on actual position;

All the cable cannot have break-down and terminal in the middle;

Cables should be straight in the hallways and turning;

Cable should be straight in the groove, and cannot beyond the groove in case of holding back the inlet and outlet holes. Cables should be banded and fixed when they are out of the groove;

User cable should be separated from the power lines.

Cables, power lines and grounding lines cannot be overlapped and mixed when they are in the same groove road. When cable is too long, it cannot hold down other cable, but structure in the middle of alignment rack;

Pigtail cannot be tied and swerved as less as possible.

Swerving radius cannot be too small (small swerving causes terrible loss of link). Its banding should be moderate, not too tight, and should be separated from other cables;

 It should have corresponding simple signal at both sides of the cable for maintaining.

Specification

Technology:

Standard: IEEE802.3, IEEE802.3u, IEEE802.3x, IEEE802.3z

Flow control: IEEE802.3x, back pressure control

Interface:

Gigabit Ethernet port: 10/100/1000Base-TX Self-adaption

Gigabit fiber port: 1000Base-X SFP

Transmission:

Twisted pair: 100M (Standard CAT5/CAT5e cable)

Multi mode fiber: 500m

Single mode fiber: 20-120Km

Exchange of attribute:

100M forward speed: 148810pps

1000M forward speed: 1488100pps

Transmission: Store and forward

Memory: 2.075Mbits

MAC address: 1K

Exchange delay time: <10 μs

Indicator:

System: RUN

Ethernet port: G1 LINK

Fiber port: G2 LINK

Remote Ethernet port alarm: G1 LFP

Remote Fiber port alarm: G2 LFP

Power supply:

Power input: 24VDC(12~48VDC)

Terminal block: 3 bits 7.62mm terminal block

No-load power consumption:1.392W@24VDC

Full-load power consumption: 1.656W@24VDC

Support reverse connection protection

Mechanical:

Shell: IP40, high strength iron shell.

Installation: DIN Rail

Weight: 346.6g

Dimension(W×H×D): 110mm×35mm×95mm

Environmental

Operating Temperature: -40 to 85°C

Storage Temperature: -45°C to 85°C

Ambient Relative Humidity:

10 to 95% (non-condensing)

Standard:

EMI: FCC Part 15, CISPR (EN55022) class A

EMS: EN61000-4-2 (ESD), Level 1

EN61000-4-4 (EFT), Level 4

EN61000-4-5 (Surge), Level 3

Shell: IEC 60068-2-27

Warranty:

Warranty time: 5 years

Certification:

CE, FCC, RoHS, PAL, UL508(pending)

Appendix

Link Fault Pass-Through(LFP): If one side link had failure, this side fiber port will send a failure alarm to remote connection, the remote fiber port will force the Ethernet port disconnect when it got the alarm, data packets will never send. The function description is as follows:

(1) Link working steadily, all indicator in regular.

(2) One Ethernet port unplug, Fiber port send the alarm, force another Ethernet port disconnect, communication interrupt, indicator OFF.

(3)When side fiber port disconnect, force all communication port interrupt, stop to communication, all indicator OFF

IMC101GT’LFP function is fore to close the connection when detected network connection failure.

advertisement

Key Features

  • Supports 10/100/1000Base-TX and 1000Base-X SFP ports
  • LFP (Link Fault Pass-Through)
  • DC12~48V power input
  • IP40 protection
  • Rugged high-strength metal case
  • DIN Rail installation
  • IEEE802.3/802.3u/802.3x/802.3z store and forward
  • -40 to 85°C working temperature

Frequently Answers and Questions

What is the power input for IMC101GT?
The power input for IMC101GT is 12~48VDC.
What is the operating temperature of IMC101GT?
The operating temperature of IMC101GT is -40 to 85°C.
What are the transmission distances for twisted pair and fiber optic cables?
The transmission distance for twisted pair cable is 100m. For multimode fiber, it is 500m. For single mode fiber, it can be 20-120Km.
What is the function of LFP (Link Fault Pass-Through)?
LFP function is used to close the connection when a network connection failure is detected. If one side link fails, the fiber port sends a failure alarm to the remote connection, forcing the Ethernet port to disconnect.
What does the LED indicator on the IMC101GT show?
The LED indicator shows the working status of the device. It has LEDs for system, Ethernet port, fiber port, and remote Ethernet/fiber port alarms.