IMC101GT
Industrial gigabit Ethernet
Media converter
User manual
Shenzhen 3onedata Technology Co.,Ltd
Tel: +86-755-26702668 Fax: +86-755-26703485 www.3onedata.com
【
Introduction】
IMC101GT is a kind of industrial gigabit media converter, it support 1 10Base-T/100Base-TX/1000 Base-TX port and 1
1000Base-X SFP port. It support LFP function, it is easy to check the network connection status,, it also support CE,FCC standard, IMC101GT adopt industry standard design, IP40 protection, rugged high-strength metal case, power supply input(12V~48VDC), -40 to 85°C working temperature.
【
Packing list】
Please check the package and all the components inside are in good condition before you use the switch.
IMC101GT x1
User manual x1
Warranty card x1
DIN rail x1
The equipment built-in precision devices, please note gently, avoiding excessive vibration to avoid affecting device performance. If you find the equipment was damaged in transit or any parts are missing, please inform our company or the dealer, we will give you proper solution as soon as possible.
【
Features】
Support 1 port 10/100/1000 Base-TX and 1 port
1000Base-X SFP
Support IEEE802.3/802.3u/802.3x/802.3z store and forward
Ethernet port support 10/100/1000M self-adaption
Support LFP(Link Fault Pass-Through)
DC12~48V power input
IP40 protect grade, high strength iron shell, DIN Rail installation.
【
Panel Layout】
1. PWR power input (3 bots terminal block)
2. Working status indicator
3. Fiber port connection indicator
4. Remote fiber port alarm indicator
5. 1000Base-X SFP port
6. 10Base-T/100Base-TX/1000 Base-TX port
7. Ethernet port connection indicator
8. Remote Ethernet port alarm indicator
9. Company name and Product name label
10. DIN-Rail
11. Grounding screw
Unit (mm)
【
Power Input】
12~48VDC
IMC101GT provides 3 bits terminal block (V-, FG, V+), V-,
V+ is 12VDC ~ 48VDC power input. It can also work if connection opposite.
【
Communication Interface
】
10Base-T/100Base-TX/1000 Base-TX Ethernet port
10Base-T/100Base-TX/1000 Base-TX Ethernet port use in front panel, It is RJ45 port, the PIN define of RJ45 is as follows: connection adopt UTP or STP, the distance is no more
than 100m, 1000Mbps use cat5e, 100Mbps use cat5, 10Mbos use cat3,4, 5.
RJ45 port support MDI/MDI-X self-adaption. In (MDI),
PIN1, 2, 3, 4, 5, 6, 7, 8 connect corresponding, in (MDI-X)
PIN1→3, 2→6, 3→1, 6→2, 4→7, 5→8, 7→4, 8→5. In
MDI/MDI-X, 1000 Base-TX PIN define is as follows:
1 8
6
7
8
4
5
2
3
PIN
1
MDI MDI-X
BI_DA+/TX+ BI_DB+/RX+
BI_DA-/TXBI_DB-/RX-
BI_DB+/RX+ BI_DA+/TX+
BI_DC+/—
BI_DC-/—
BI_DD+/—
BI_DD-/—
BI_DB-/RXBI_DA-/TX-
BI_DD+/— BI_DC+/—
BI_DD-/— BI_DC-/—
Note : 10Base-T/100Base-TX , “TX±”transmit data±, “RX±”receive data±,
“—”not use.
MDI:
MDI-X:
1000Base-X SFP fiber port
1000Base-X fiber port is SFP multi mode or single mode port, it supports LFP.
Suggestion: please make a mark for your optic fiber
(Picture as follows: A-A, B-B or A1-A2, B1-B2) Easy to use
【
LED Indicator】
LED indicator in front panel of IMC101GT monitor working status, the function of each LED is described in the table as below.
LED
RUN
LINK(G1)
LINK(G2)
LFP(G1)
LFP(G2)
System indication LED
State Description
ON/OFF Switch is unwonted
Blinking Switch is active
ON
Blinking
OFF
ON
OFF
ON
OFF
ON
OFF
Local Ethernet port connection regular.
Local Ethernet port connection active
Local Ethernet port had no connection.
Local Fiber port connection regular and active.
Local fiber port had no connection.
Remote Ethernet port had no connection or unwonted
Remote Ethernet port connection regular.
Remote fiber port had no connection or unwonted
Remote fiber port connection regular.
Installation:
Before installation, confirm that the work environment meet the installation require, including the power needs and abundant space. Whether it is close to the connection equipment and other equipments are prepared or not.
Installation require as below
1. Avoid in the sunshine, keep away from the heat fountainhead or the area where in intense EMI.
2. Examine the cables and plugs that installation requirements.
3.Examine whether the cables be seemly or not (less than 100m) according to reasonable scheme.
4. Screw, nut, tools provide by yourselves.
5.Power need: power inputs(12~48DC)
6. Environment: -40°C to 85°C
Storage Temperature: -40°C to 85°C
Relative humidity 10% to 95%
DIN-Rail Installation
In order to use in industrial environments expediently, IMC101G adopt 35mm DIN-Rail installation, the installation steps as fellows:
1. Examine the DIN-Rail attachment
2. Examine DIN Rail whether be firm and the position be suitability or not.
3. Insert the top of the DIN-Rail into the slot just below the stiff metal spring.
4. The DIN-Rail attachment unit will snap into place as shown below.
Wiring Requirements
Wiring need to meet the following requirements:
It is needed to check whether the type, quantity and specification of cable match the requirement before cable laying;
It is needed to check the cable is damaged or not, factory records and quality assurance booklet before cable
laying;
The required cable specification, quantity, direction and laying position need to match construction requirements, and cable length depends on actual position;
All the cable cannot have break-down and terminal in the middle;
Cables should be straight in the hallways and turning;
Cable should be straight in the groove, and cannot beyond the groove in case of holding back the inlet and outlet holes. Cables should be banded and fixed when they are out of the groove;
User cable should be separated from the power lines.
Cables, power lines and grounding lines cannot be overlapped and mixed when they are in the same groove road. When cable is too long, it cannot hold down other cable, but structure in the middle of alignment rack;
Pigtail cannot be tied and swerved as less as possible.
Swerving radius cannot be too small (small swerving causes terrible loss of link). Its banding should be moderate, not too tight, and should be separated from other cables;
It should have corresponding simple signal at both sides of the cable for maintaining.
【
Specification】
Technology:
Standard: IEEE802.3, IEEE802.3u, IEEE802.3x, IEEE802.3z
Flow control: IEEE802.3x, back pressure control
Interface:
Gigabit Ethernet port: 10/100/1000Base-TX Self-adaption
Gigabit fiber port: 1000Base-X SFP
Transmission:
Twisted pair: 100M (Standard CAT5/CAT5e cable)
Multi mode fiber: 500m
Single mode fiber: 20-120Km
Exchange of attribute:
100M forward speed: 148810pps
1000M forward speed: 1488100pps
Transmission: Store and forward
Memory: 2.075Mbits
MAC address: 1K
Exchange delay time: <10 μs
Indicator:
System: RUN
Ethernet port: G1 LINK
Fiber port: G2 LINK
Remote Ethernet port alarm: G1 LFP
Remote Fiber port alarm: G2 LFP
Power supply:
Power input: 24VDC(12~48VDC)
Terminal block: 3 bits 7.62mm terminal block
No-load power consumption:1.392W@24VDC
Full-load power consumption: 1.656W@24VDC
Support reverse connection protection
Mechanical:
Shell: IP40, high strength iron shell.
Installation: DIN Rail
Weight: 346.6g
Dimension(W×H×D): 110mm×35mm×95mm
Environmental
Operating Temperature: -40 to 85°C
Storage Temperature: -45°C to 85°C
Ambient Relative Humidity:
10 to 95% (non-condensing)
Standard:
EMI: FCC Part 15, CISPR (EN55022) class A
EMS: EN61000-4-2 (ESD), Level 1
EN61000-4-4 (EFT), Level 4
EN61000-4-5 (Surge), Level 3
Shell: IEC 60068-2-27
Warranty:
Warranty time: 5 years
Certification:
CE, FCC, RoHS, PAL, UL508(pending)
Appendix:
Link Fault Pass-Through(LFP): If one side link had failure, this side fiber port will send a failure alarm to remote connection, the remote fiber port will force the Ethernet port disconnect when it got the alarm, data packets will never send. The function description is as follows:
(1) Link working steadily, all indicator in regular.
(2) One Ethernet port unplug, Fiber port send the alarm, force another Ethernet port disconnect, communication interrupt, indicator OFF.
(3)When side fiber port disconnect, force all communication port interrupt, stop to communication, all indicator OFF
IMC101GT’LFP function is fore to close the connection when detected network connection failure.