Chief SYSAU Projector System Installation Instructions

Chief SYSAU Projector System Installation Instructions

Below you will find brief information for Projector System SYSAU. The SYSAU is a universal interface suspended ceiling projector system that allows you to mount your projector to a suspended ceiling. It features a 360-degree column rotation, adjustable height, and roll, pitch, and yaw adjustments. The SYSAU also has built-in cable management for a clean and organized installation.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Projector System SYSAU Installation Instructions | Manualzz

I N S T A L L A T I O N I N S T R U C T I O N S

Universal Interface Suspended Ceiling

Projector System

SYSAU

SYSAU

DISCLAIMER

Milestone AV Technologies and its affiliated corporations and subsidiaries (collectively “Milestone”), intend to make this manual accurate and complete. However, Milestone makes no claim that the information contained herein covers all details, conditions or variations, nor does it provide for every possible contingency in connection with the installation or use of this product. The information contained in this document is subject to change without notice or obligation of any kind. Milestone makes no representation of warranty, expressed or implied, regarding the information contained herein. Milestone assumes no responsibility for accuracy, completeness or sufficiency of the information contained in this document.

Chief® is a registered trademark of Milestone AV Technologies.

All rights reserved.

Installation Instructions

WARNING:

Exceeding the weight capacity can result in serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the combined weight of all components attached to the SYSAU does not exceed 35 lbs

(15.9 kg).

WARNING:

Use this mounting system only for its intended use as described in these instructions. Do not use attachments not recommended by the manufacturer.

WARNING:

Never operate this mounting system if it is damaged. Return the mounting system to a service center for examination and repair.

DEFINITIONS

WARNING:

A WARNING alerts you to the possibility of serious injury or death if you do not follow the instructions.

WARNING:

Do not use this product outdoors.

CAUTION:

A CAUTION alerts you to the possibility of damage or destruction of equipment if you do not follow the corresponding instructions.

IMPORTANT ! :

The SYSAU has been designed to be mounted above or flush with a suspended ceiling secured by a

WireVice system.

MOUNTING SYSTEM:

A MOUNTING SYSTEM is the primary Chief product to which an accessory and/or component is attached.

IMPORTANT ! :

The SYSAU has been designed to support a single electrical receptacle, a double electrical receptacle or both.

ACCESSORY:

AN ACCESSORY is the secondary Chief product which is attached to a primary Chief product, and may have a component attached or setting on it.

NOTE:

It is the installer’s responsibility to ensure that the enclosure is bonded to the ground in the switch box, in accordance with the National Electric Code, ANSI/

NFPA 70 or Canadian Electrical Code, CSA C22.1.

--SAVE THESE INSTRUCTIONS--

COMPONENT:

A COMPONENT is an audiovisual item designed to be attached or resting on an accessory or mounting system such as a video camera, CPU, screen, display, projector, etc.

2

IMPORTANT SAFETY INSTRUCTIONS

WARNING:

Failure to read, thoroughly understand, and follow all instructions can result in serious personal injury, damage to equipment, or voiding of factory warranty! It is the installer’s responsibility to make sure the mounting system is properly assembled and installed using the instructions provided.

WARNING:

Failure to provide adequate structural strength for this mounting system can result in serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the structure to which this mounting system is attached can support five times the combined weight of all equipment. Reinforce the structure as required before installing the mounting system.

Installation Instructions

DIMENSIONS

SYSAU

503.5

19.82

MOUNT AND

COLUMN ASSEMBLED

88.3

3.48

8.6

.34

79.7

3.14

12.7

.50

COLUMN ADJUSTMENT

INCREMENT

129.1

5.08

415.2

16.35

294.7

11.60

374.3

14.74

NOTE:

1.

2.

3.

4.

THIS IS A 4 SHEET DRAWING

SHEET 2 - CEILING PLATE

SHEET 3 - PROJECTOR MOUNT AND COLUMN

SHEET 4 - UNIVERSAL INTERFACE

DIMENSIONS: [MILLIMETERS]

INCHES

360 DEGREES OF COLUMN

ROTATION REMOVABLE ELECTRICAL

INSTALL PLATE

234.2

9.22

COLUMN TRAVEL

300.8

11.84

COLUMN LATCH

POSITION FOR COLUMN

SECURITY BOLT

589

23.19

633.6

24.94

592

23.31

COLUMN CLAMP LEVER

SET SCREW LOCATIONS PROVIDED

TO SECURE PLATE TO CEILING GRID

MOVEABLE/REMOVABLE

HOOKS

1.03 ADJUSTMENT RANGE

47.7

1.88

21.5

.85

66.5

2.62

116.8

4.60

50.3

1.98

155.4

6.12

184.2

7.25

DIMENSIONS: [MILLIMETERS]

INCHES

3

SYSAU

DIMENSIONS - continued

3° ROLL ADJUSTMENT

PITCH MICRO

ADJUST KNOB

10° YAW ADJUSTMENT

ROLL

MICRO/MACRO

ADJUST KNOB

ROLL MICRO

ADJUST KNOB

176.6

6.95

PITCH

MICRO/MACRO

ADJUST KNOB

CABLE ROUTING TIE-OFF (4)

YAW MICRO

ADJUST KNOB

YAW

MICRO/MACRO

ADJUST KNOB

45.1

1.78

177.8

7.00

DIMENSIONAL VIEWS OF MOUNT SHOWN WITHOUT COLUMN

TO INCREASE CLARITY

348.9

13.73

PROJECTOR LENS DIRECTION

ALIGNMENT MARK

4

353.3

13.91

157.8

6.21

MOUNTING PATTERN LIMITS

ADJUSTABLE

FEET

153

6.02

115.7

R4.55

34.5

1.36

100.2

3.94

115.2

4.53

1.

2.

NOTE:

143.3

5.64

INTERFACE SHOWN ASSEMBLED, SHIPPED AS LOOSE PIECES

FOUR LEGS SHOWN, A MINIMUM OF THREE LEGS MUST BE USED

TO PROPERLY MOUNT THE PROJECTOR

Installation Instructions

10° PITCH ADJUSTMENT

DIMENSIONS: [MILLIMETERS]

INCHES

DIMENSIONS: [MILLIMETERS]

INCHES

Installation Instructions

LEGEND

Tighten Fastener

Apretar elemento de fijación

Befestigungsteil festziehen

Apertar fixador

Serrare il fissaggio

Bevestiging vastdraaien

Serrez les fixations

Loosen Fastener

Aflojar elemento de fijación

Befestigungsteil lösen

Desapertar fixador

Allentare il fissaggio

Bevestiging losdraaien

Desserrez les fixations

Phillips Screwdriver

Destornillador Phillips

Kreuzschlitzschraubendreher

Chave de fendas Phillips

Cacciavite a stella

Kruiskopschroevendraaier

Tournevis à pointe cruciforme

Open-Ended Wrench

Llave de boca

Gabelschlüssel

Chave de bocas

Chiave a punte aperte

Steeksleutel

Clé à fourche

By Hand

A mano

Von Hand

Com a mão

A mano

Met de hand

À la main

Hex-Head Wrench

Llave de cabeza hexagonal

Sechskantschlüssel

Chave de cabeça sextavada

Chiave esagonale

Zeskantsleutel

Clé à tête hexagonale

Adjust

Ajustar

Einstellen

Ajustar

Regolare

Afstellen

Ajuster

Remove

Quitar

Entfernen

Remover

Rimuovere

Verwijderen

Retirez

Pencil Mark

Marcar con lápiz

Stiftmarkierung

Marcar com lápis

Segno a matita

Potloodmerkteken

Marquage au crayon

Drill Hole

Perforar

Bohrloch

Fazer furo

Praticare un foro

Gat boren

Percez un trou

Optional

Opcional

Optional

Opcional

Opzionale

Optie

En option

Security Wrench

Llave de seguridad

Sicherheitsschlüssel

Chave de segurança

Chiave di sicurezza

Veiligheidssleutel

Clé de sécurité

SYSAU

5

SYSAU

TOOLS REQUIRED FOR INSTALLATION

#2

5/32"

(security)

Installation Instructions

PARTS

(A) Hardware Bag 9900-002214 [Hardware bag markings match second letter of hardware]

AA (4)

M2.5x10mm

AB (4)

M3x10mm

AC (4)

M4x10mm

AD (4)

M5x14mm

AE (4)

M6x14mm

AF (4)

M4x25mm

AG (4)

M6x25mm

AH (4)

M5x25mm

AI (4)

M3x25mm

AJ (4)

M4

AK (4)

.500x.256x.625"

AL1 (4)

10-24 x 3/8"

AL2 (1)

5/32" (security)

AM (4)

[Screw adapters]

AN (4)

1/4-20

(B) Hardware Bag 9900-002225 [Hardware bag markings match second letter of hardware]

BA (1)

[Column trim ring]

BB (1)

[Ceiling tile cutter]

BF (1)

1/4-20 x 5/8"

BG1 (1)

10-24 x 1/4"

(security)

BG2 (1)

5/32"

(security)

BC (4)

.262 x 1-5/16"

[Screw eye]

BH (8)

10-24 x 5/8"

BD (4)

[Cable lock]

BE (4)

1/4" x 2"

[Wire anchor]

BI (4)

1/16" x 25’

[Cable]

P (1)

[Universal interface plate]

Q (4)

[Universal interface leg]

S (1)

[Projector mount and

column]

R (1)

[Suspended ceiling plate assembly]

6

Installation Instructions SYSAU

ASSEMBLY AND INSTALLATION

Attach Universal Interface to Projector

WARNING:

Exceeding the weight capacity can result in serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the combined weight of all components attached to the SYSAU does not exceed 35 lbs

(15.9 kg).

IMPORTANT ! : The longer screws (AF through AI) and spacers (AK) may be used if there is interference between interface legs and any part of the projector, and if more height is required to clear elevated surfaces of the projector.

CAUTION:

USING SCREWS OF IMPROPER SIZE MAY

DAMAGE PROJECTOR. Properly sized screws will easily and completely thread into projector threaded inserts.

1.

Determine proper size screw to fit the threaded inserts in projector. Test Phillips screws (AA-AE) provided until one fits the projector holes.

2.

Insert screws through M4 flat washers (AJ), if required, screw adapters (AM) with height-adjustable nuts and into projector threaded inserts. (See Figure 1)

IMPORTANT ! : At least three or, if possible, four interface legs MUST be used to attach projector to universal interface plate.

NOTE:

Only use washers (AJ) if using AA or AB screws to attach screw adapters (AM) to projector.

2

(AA through AI) x 3 or 4

(AJ)

(with AA or AB only)

Height-adjustable

nut

3

Fully lowered

Figure 2

NOTE:

Make sure interface legs (Q) are in the UNLOCKED position. (See Figure 3)

(AM)

(Q)

Figure 1

3.

Adjust height-adjustable nuts (on screw adapters [AM]) to desired level. (See Figure 2)

NOTE:

Height-adjustable nuts should be adjusted as low as possible while still allowing interface legs (Q) to clear elevated surfaces on the projector. (See Figure 2)

Adjust height-adjustable nuts to the same level on all adapter screws to ensure a level mount.

5 LOCKED

UNLOCKED

Figure 3

7

SYSAU

4.

Place interface legs (Q) over screw adapters (AM). (See

Figure 4)

Example: 3 leg attachment

4

(Q) x 3 or 4

8

(AN) x 3

(AM) x 3 or 4

Installation Instructions

Example: 3 leg attachment

(P)

Sliding mounting

screws

Figure 4

5.

Ensure that interface leg is firmly seated over screw adapter, and pull out end of interface leg to lock in place over screw adapter. (See Figure 3)

6.

Repeat Step 5 for remaining legs.

WARNING:

BE SURE THAT UNIVERSAL INTERFACE

LEGS ARE LOCKED OVER SCREW ADAPTERS. Projector may fall from the mount causing serious injury or death if legs are not securely locked over screw adapters!

7.

Maneuver interface legs (Q) and slide mounting screws in top of interface legs so that mounting screws are properly located to mount universal interface plate (P) over projector’s center of gravity via attachment to interface legs.

(See Figure 5)

8.

Secure interface plate to interface legs by installing 1/4-20" wing nuts (AN) to screws on interface legs. (See Figure 5)

NOTE:

The following example is one possible scenario based on one example projector hole pattern. Specific connection points vary dependent on projector hole pattern. Multiple scenarios may be used for each specific hole pattern as long as the weight of the projector is centered and balanced after mounting.

IMPORTANT ! : At least three or, if possible, four interface legs MUST be used to attach projector to universal interface plate.

Figure 5

8

Installation Instructions

INSTALLING THE SUSPENDED CEILING PLATE

NOTE:

The SYSAU has been designed to be mounted above or flush with a suspended ceiling secured by a

WireVice system. The method used may be determined by the existing ceiling system.

1.

Remove outlet plate from suspended ceiling plate assembly

(R) if electrical outlet will be installed (See Figure 6), and install UL Listed Raco 256, 232 or equivalent UL Listed electrical box (not included) to SYSAU outlet plate following instructions included with electrical box.

1

SYSAU

4.

Installing on Top of Existing Ceiling Tile only: Press center tip of ceiling tile cutter (BB) into finished side of ceiling tile at marked location. Cut extension column hole through tile using back and forth motion.

5.

Installing on Top of Existing Ceiling Tile only: Reinstall ceiling tile with extension column hole. Ensure tile is oriented for proper location of hole.

6.

Installing on Top of Existing Ceiling Tile only: Install suspended ceiling plate assembly (R) on top of ceiling tile so that end brackets engage primary (1-1/2" (38mm) high) rails of ceiling framework. (See Figure 8)

6

7

= 1.5" (38mm)

Electrical plate

(R)

Figure 6

2.

Determine exact location of column. Mark location on lower

(finished) side of ceiling tile. (See Figure 7)

• Flush with Suspended Ceiling

Mark location on ceiling tile framework.

• Install on Top of Existing Ceiling Tile

Mark location on lower (finished) side of ceiling tile.

2

Figure 8

7.

Flush with Suspended Ceiling only: Install suspended ceiling plate assembly (R) on top of ceiling framework rails so that end brackets engage primary (1-1/2" (38mm) high) rails of ceiling framework. (See Figure 8)

8.

Loosen two wing nuts at each end of ceiling plate assembly.

(See Figure 9)

9.

Raise or lower adjustable bracket, as necessary, at each end of the ceiling plate assembly.

10. Tighten wing nuts on adjustable bracket at each end of the ceiling plate assembly. (See Figure 9)

8

10

x 4

9

Figure 7

Be sure to consider the following items when determining column location:

• Dimensional offset of display/projector relative to column (due to mount and/or interface).

• For Projectors: Any recommended dimensions of projector relative to target. (See installation instructions included with the projector.)

3.

Remove affected ceiling tile and any adjacent tiles required for access.

9

9

Figure 9

9

SYSAU

11. Loosen three wing nuts in upper side of ceiling plate assembly (R) to adjust the lateral shift of the column support. (See Figure 10)

12. Position column support (as required) to center support over ceiling tile hole. (See Figure 10)

13. Tighten wing nuts to prevent further movement of column support. (See Figure 10).

11

Installing Support Cable

Installation Instructions

WARNING:

Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment.

Reinforce the structure as required before installing the component.

Solid Concrete Ceiling Structure

x 3

13

12

Figure 10

14. OPTIONAL -- Installing on Top of Existing Ceiling Tile

only: Mark location of electrical cutout on ceiling tile with pencil.

15. Examine ceiling structure (concrete or wood) above ceiling plate assembly (R) to identify four support cable anchor locations. Each location should be approximately 15° outboard of support holes in ceiling plate assembly (R) (See

Figure 11).

16. Mark locations with pencil.

WARNING:

Anchors must be installed into structurally sound solid concrete with a minimum thickness of 4"

(101.6mm) or greater. Installation into hollow concrete block, mortar, or concrete that exhibits cracking, spalling, or other defects may result in failure of anchor and serious personal injury or damage to equipment!

1.

Drill 1/4" diameter x 1-1/2" deep hole at each marked cable anchor support location (See Figure 12). Ensure hole is at least 2-1/2" from nearest concrete edge. Remove debris from hole.

16

x 4

15°

x 4

15°

x 4

1

3

1/4"

2

(BE)

4

(BI)

Figure 12

2.

Tap anchor (BE) into each hole until the anchor head is seated in the hole. (See Figure 12)

(R)

Figure 11

17. Remove ceiling plate assembly (R) and ceiling tile.

OPTIONAL: Cut electrical box opening in ceiling tile at marked location.

10

WARNING:

Failure to properly set anchor may result in failure of anchor and serious personal injury or damage to equipment!

3.

Using claw portion of hammer, set each anchor (BE) by pulling it out of hole approximately 1/4" (6.4mm). (See

Figure 12)

4.

Insert portion of manufactured loop on cable (BI) through hole in anchor (BE). Insert end of cable (BI) through loop.

Repeat for 3 remaining support locations. (See Figure 12)

Installation Instructions

Wood Ceiling Structure

WARNING:

Anchors must be installed into wood that measures at least 3-1/2" x 1-1/2" (88.9mm x 38.1mm), and the anchor must install in the center of the narrower (1-1/2"

[38.1mm]) face.

1.

Drill 5/32" diameter x 2" deep hole at each marked cable anchor support location (See Figure 13). Remove debris from hole.

OPTIONAL

additional

fasteners (BH)

(R)

610mm (24 in.)

625mm (24-5/8 in.)

3

SYSAU

(BH) x 4

OPTIONAL

additional

fasteners (BH)

OPTIONAL

additional

fasteners (BH)

Figure 14

3

(BH) x 4

1

5/32"

2

(BC)

3

(BI)

Figure 13

2.

Fully thread eye lag (BC) into each hole (See Figure 13).

3.

Route end of cable (BI) through eye lag (BC) and then through cable loop (See Figure 13). Repeat for 3 remaining support locations.

Completing Ceiling Plate Assembly Installation

1.

Installing on Top of Existing Ceiling Tile only: Reinstall ceiling tile with extension column hole. Ensure tile is oriented for proper location of hole.

2.

Installing on Top of Existing Ceiling Tile only: Reinstall ceiling plate assembly (R) on top of ceiling tile so that extension column support is centered over hole in tile.

3.

Position ceiling plate assembly (R) with four screws (BH) as required:

For 625mm (24-5/8 in.) Framework: Install screws through end bracket inside holes. (See Figure 14)

For 610mm (24 in.) Framework: Install screws through end bracket inside holes. (See Figure 14)

For 600mm (23-5/8 in.) Framework: Install screws through end bracket outside holes. (See Figure 15)

OPTIONAL: An additional four screws (BH) may be used (if desired) to further secure the ceiling plate assembly in place and prevent any movement. (See Figure 14) and (See Figure 15)

600mm (23-5/8 in.)

Figure 15

OPTIONAL

additional

fasteners (BH)

R

11

SYSAU

CAUTION:

Failure to properly tension cables (BI) may result in damage to ceiling tile framework!

4.

Thread each cable (BI) completely through cable lock (BD), corresponding hole in corner of ceiling plate assembly (R), and completely through opposite side of cable lock (BD).

(See Figure 16)

5.

Adjust cable tension until ceiling plate assembly (R) is supported entirely and evenly by all four support cables, but not so tight as to distort ceiling tile framework.

NOTE:

Cable lock (BD) will allow cable to enter from only one direction per side, indicated by arrows on lock.

Depress spring loaded pins on cable lock (BD) to release cable tension.

Installation Instructions

3.

Move projector mount and column upward to desired position. The mount and column will lock into place as soon the column’s upward motion is stopped.

4.

If necessary, pull up on the release ring found on the suspended ceiling plate assembly (R) in order to move the column downward. (See Figure 18)

(S)

(R)

2

(R)

Projector mount lock

S

C

R

E

E

N

Figure 17

5.

Push lock lever up to stabilize motion of the projector mount.

(See Figure 18)

Release ring

Lock lever

(BD)

6

(BF)

5

spring-loaded

pin

4

(BI, BD) x 4

(BI)

Figure 16

Installing Projector Mount and Column

SC

4

R

EE

N

WARNING:

Exceeding the weight capacity can result in serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the combined weight of all components attached to the SYSAU up to (and including) the display/projector, does not exceed 35 lbs (15.9 kg).

NOTE:

The column may be shortened if there are space limitations above the ceiling plate.

1.

OPTIONAL: Use a band saw or similar sawing device to remove the desired length of column.

IMPORTANT ! : At least one full hole (on side of column) must be visible above the upper clamping system. (See

Figure 18)

NOTE:

Be sure to line up the projector mount so that it faces the screen. The projector mount lock will appear on the left side of the assembly. (See Figure 17)

2.

Install projector mount and column (S) from underneath and up through suspended ceiling plate assembly (R). (See

Figure 17)

7

Upper clamping system

(BG1)

Location for security screw

(BG1)

SIDE VIEW

Figure 18

6.

Install one 1/4-20 x 5/8" button head screw (BF) into extension column in first opening above column collar, tightening firmly against column. (See Figure 18)

7.

Install one 10-24 x 1/4" security button head screw (BG1) into column mechanism on suspended ceiling plate assembly to prevent movement of the release ring and further movement of the column. (See Figure 18)

12

Installation Instructions

8.

Flush with Suspended Ceiling only: Re-install ceiling tile to fit along side(s) of SYSAU. (See Figure 19)

SYSAU

3.

Slide projector with interface bracket into mounting slots in mount base until thumb nuts are seated in the narrow portion of mounting slots against the opposite side of mounting slots. (See Figure 21)

Example: 3 leg attachment

S

CREE

N

8

Figure 19

9.

OPTIONAL: Install column trim ring (BA) on extension column below or flush with ceiling tile .

(See Figure 20)

9

(BA)

Thumb nuts

2

3

Thumb nut

Mounting slot

Figure 21

4.

Move locking lever to "Locked" position. (See Figure 22)

5.

Insert key into lock and turn to secure projector to projector mount.

S

CRE

E

N

Installing Projector

Figure 20

WARNING:

IMPROPER INSTALLATION CAN LEAD TO

PROJECTOR FALLING RESULTING IN SERIOUS

PERSONAL INJURY OR DAMAGE TO EQUIPMENT. Make certain mounting slots in projector mount base slide under thumb screws and that screws are seated in the back of slots.

1.

Orient projector with interface bracket so that the projector mount lock appears on the left side of the assembly (when viewed from screen). (See Figure 21)

2.

Lift projector so that thumb nuts on attached interface bracket are aligned with mounting slots in projector mount base.

Lock

LOCK

position

Locking lever

5

Figure 22

4

UNLOCK

position

13

SYSAU

Adjustments

NOTE:

Be sure to use the correct adjustment feature (Yaw,

Roll or Pitch) when adjusting the projector mount.

(See Figure 23)

YAW Adjustment

1.

Turn the YAW adjustment locking knob (Y) counterclockwise (to the left) to UNLOCK (disengage) the drive.

2.

Adjust the YAW freely to the desired macro position, as required.

3.

Turn the YAW adjustment locking knob (Y) clockwise (to the right) to LOCK (engage) the drive.

4.

Turn YAW micro-adjustment knob right or left until image is properly aligned on target. (See Figure 23)

ROLL Adjustment

5.

Turn the ROLL adjustment locking knob (R) counterclockwise (to the left) to UNLOCK (disengage) the drive.

6.

Adjust the ROLL freely to the desired macro position, as required.

Installation Instructions

7.

Turn the ROLL adjustment locking knob (R) clockwise (to the right) to LOCK (engage) the drive.

8.

Turn ROLL micro-adjustment knob right or left until image is properly aligned on target. (See Figure 23)

PITCH Adjustment

9.

Turn the PITCH adjustment locking knob (P) counterclockwise (to the left) to UNLOCK (disengage) the drive.

10. Adjust the PITCH freely to the desired macro position, as required.

11. Turn the PITCH adjustment locking knob (P) clockwise (to the right) to LOCK (engage) the drive.

12. Turn PITCH micro-adjustment knob right or left until image is properly aligned on target. (See Figure 23)

1

3

UNLOCKED

LOCKED

4

Projector mount lock

YAW

PITCH

ROLL

12

9

11

8

5

7

Figure 23

14

Installation Instructions

Cable Management

1.

Open the cable management cover on the column by opening the side with double raised edge. (See Figure 24)

NOTE:

The cable management cover may also be slid out of place along the column length.

2.

Place cables behind cover and close cover.

3.

Cables may be secured using zip-ties (not included) through cable management points on projector mount. (See

Figure 24)

Open this side of cable management cover

Hinged side

Figure 24

Secure cable using zip-ties (not included)

SYSAU

15

SYSAU Installation Instructions

Chief, a products division of

Milestone AV Technologies

8800-002822 Rev00

2016 Milestone AV Technologies

www.chiefmfg.com

03/16

USA/International

A 6436 City West Parkway, Eden Prairie, MN 55344

P

800.582.6480 / 952.225.6000

Europe

F

877.894.6918 / 952.894.6918

A Franklinstraat 14, 6003 DK Weert, Netherlands

P

+31 (0) 495 580 852

F

+31 (0) 495 580 845

Asia Pacific

A Office No. 918 on 9/F, Shatin Galleria

18-24 Shan Mei Street

Fotan, Shatin, Hong Kong

P

852 2145 4099

F

852 2145 4477

advertisement

Key Features

  • Universal interface
  • Suspended ceiling mount
  • 360-degree column rotation
  • Adjustable height
  • Roll, pitch, and yaw adjustments
  • Built-in cable management

Frequently Answers and Questions

What is the weight capacity of the SYSAU?
The SYSAU has a weight capacity of 35 lbs (15.9 kg).
How do I adjust the height of the SYSAU?
You can adjust the height of the SYSAU by loosening the wing nuts on the adjustable bracket at each end of the ceiling plate assembly. Then raise or lower the bracket to the desired height and tighten the wing nuts.
How do I adjust the projector's position on the SYSAU?
You can adjust the projector's position by using the roll, pitch, and yaw adjustments. Each adjustment has a locking knob that you can turn to unlock the drive. Once unlocked, you can freely adjust the projector to the desired position. Then turn the locking knob to lock the drive. You can also fine-tune the adjustment using the micro-adjustment knobs.

Related manuals

Download PDF

advertisement