Below you will find brief information for Fiber Optic Link CFO400 CFO401, Fiber Optic Link CFO400 CFO431, Fiber Optic Link CFO400 CFO451. This manual describes how to configure the settings of the CFO400 series fiber optic link for use with a CRT401/431/451 and CRR401/431 units. The manual provides instructions on making the terminal connection to the device, using the management software commands to configure and control the units, and troubleshooting common issues. The document also includes information on the CFO Backplane Euro Connector and demo numbers for simulation and testing.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

CFO400 CFO401, CFO400 CFO431, CFO400 CFO451 User Manual | Manualzz

CFO400 Series

MANAGEMET SOFTWARE FOR

CFO401/431/451 UNITS

CFO400sw1 User Manual, 59300066, rev001

Contents

Introduction ........................................................................................................................... 1

Management Software for CFO401/431/451 Units .............................................................. 2

General ........................................................................................................................... 2

System Requirements .................................................................................................... 2

How to Make the Terminal Connection ........................................................................2-3

Management Software Commands ................................................................................ 3

CFO401/431/451 Help View...................................................................................... 3

Description of Commands......................................................................................... 4

Description of Status Listing ..................................................................................... 4

Transimitter’s Status Listing View .............................................................................. 5

Receiver’s Status Listing View .................................................................................. 5

CFO401/431/451 Info Codes ................................................................................................. 6

CFO Backplane Euro Connector .......................................................................................... 7

Demo Numbers for CFO401/431/451 Simulations and Testing ......................................... 7

Copyright Acknowledgements ............................................................................................. 8

Management Software for CFO401/431/451 Units User Manual rev001

Management Software for CFO401/431/451

Units (SW version 1.1.23 -->)

Introduction

Management connection between CFO400 series fi bre optic link units and e.g. laptop or PSION is based on a serial data communication by means of any terminal type program.

Management software for CFO400 series fi bre optic link units

(v1.1.23 -->) is a Command Line Interface type and it is meant for confi guration and controlling of CFO401/431/451 link units

(uni-directional communication via fi bre, CRT --> CRR).

Local mgmt

CRT401/431/451

Transmitter

Uni-directional (CRT --> CRR)

remote mgmt and CRT status telemetry via fibre

CRR401/431

Receiver

Local mgmt

Management Software for CFO401/431/451

Series Units (SW version 1.1.23 -->).

Picture 1.

Naming a terminal connection.

Picture 2.

Selecting COM port.

Picture 3.

Settings for COM port.

GENERAL

This chapter tells how with help of management software you can confi gure settings of CFO400 series fi bre optic link consisting of CRT401/431/451 and CRR401/431 units.

SYSTEM REQUIREMENTS

* Any program using serial port communication and supporting VT100 / 102 or ANSI protocols, e.g. Windows

95/98 or Windows NT 4.0/2000/XP, PSION.

* RS232-cable (type CIC403). See table 1 for cable pinouts.

1. HOW TO MAKE THE TERMINAL CONNECTION

PC/PSION

Receive data

Transmit data

System ground

D9 female

2

3

5

HD15 male

2

12

15

CFO

Mgmt output

Mgmt input

Ground

Table 1.

Management cable (CIC403) pinouts (D9 female / HD15 male).

1. Start the Windows hyper terminal program (in Windows

95/98 and NT 4.0/2000/XP by choosing -> Start/

Programs/Accessories/Communications/Hyper Terminal).

Wait until the following “Connection Description” window appears on the screen (see picture 1).

2. Enter a name for connection, e.g. “CFO400 Terminal” and click OK to continue.

screen (see picture 2).

3. Choose COM port where the RS232 cable is connected, e.g. COM1 port and click OK to continue.

the screen (see picture 3). Set here the values as described in table 1. Click OK to continue. The

CFO400 Terminal” window appears on the screen (see picture 4).

4. Press Enter to activate terminal window (“AD->” appears on the screen, see picture 4). The terminal connection to CFO401/431/451 unit is now created and you can now use the management commands to controlling the unit.

2 Management Software for CFO401/431/451 Units User Manual rev001

When the management software is activated,

“AD->” text appears on the screen.

Setting Value

VT102 ANSI

Protocol Serial

Baud rate 19200

Data bits 8

Parity None

Stop bits 2

Flow control None

Table 1.

Port settings to terminal connection.

Picture 4.

The Windows Hyper terminal program window.

2. MANAGEMENT SOFTWARE COMMANDS

After making and starting the terminal connection for the

CFO401/431/451 unit it is possible with help of separate commands of management software e.g. check the status or change the settings of CRT401/431/451 and CRR401/431 units. Entering help or ? displays a list of commands (see picture 5).

**************( Teleste Action Direct Help )***************

-----------------------------------------------------------

Help/?....... Help | Reset CPU..... Reset CPU

<Tab>........ Prev. command |

<Esc>........ Clear Line | speed ........ 0 - 100 ms

| video[n] ..... 1 - 4 On/Off

status....... Status, Local |

| datatype ..... RS422/TTL

| dataterm ..... None/Hardbias/Hardbias+Term

| audio ........ 600/High

alias ....... Element Name | cc1=vsa....... CC out = Video Source Alarm

vers......... SW Version | cc1=off....... CC out = Off

demonr #..... Set Demo Mode | factoryset.... Defaults

tv .......... Set Test Value |

-----------------------------------------------------------

Picture 5.

CFO401/431/451 “help” view.

Management Software for CFO401/431/451 Units User Manual rev001 3

2.1. Description of commands

Note! Remote commands can be sent only from CRT to

CRR via fi bre. Due to one-way operation no replies are received from CRR to CRT.

help / ? - Displays a list of commands.

rc [command] [value] - Remote command (only from CRT to

CRR!) e.g. changing CRR’s audio to high -> rc audio high.

status - (when cable is connected to CRT) Displays a status of CRT unit (see picture 6).

status - (when cable is connected to CRR) Displays a status of CRR unit (see picture 7).

status rc - (when cable is connected to CRR) Displays a status of CRT unit (see picture 6).

factoryset - Sets default factory settings.

alias [name] - Alias naming (the maximum is 32 characters).

vers - Displays application software version, alias name, hardware version and serial number of the local unit.

about - Additional information displays. Includes e.g. info code explanations describing the link status (during malfunction info codes are echoed to the prompt).

reset cpu - Resets cpu (same effect as taking power off).

chat [value] - Displays max 40 chr text (only from CRT to CRR).

speed [0-100] - The value (ms) defi nes speed that terminal’s text is printed on the screen.

datatype [value] - Changes datatype settings.

dataterm [value] - Changes dataterm settings.

audio [value] - Changes audio input settings.

cc1=vsa - Changes cc output channel to video source alarm.

cc1=cc1 - Changes video source alarm to cc output channel.

4 Management Software for CFO401/431/451 Units User Manual rev001

2.2. Description of status listing

Supply voltage - Shows unit’s supply voltage.

Module Temperature - Shows unit’s internal temperature.

Hours:Mins, local - Unit’s usage hour meter.

Module address - Shows slot where the unit is installed (not in use).

Link Status - Shows link’s status

Module Status - Shows module’s status.

Delay between bytes - Shows terminal’s display speed.

CH1, 2, 3 & 4 - Shows video’s status.

CC / Vid Src Alarm - Shows cc output channel’s status.

Data Type - Shows data’s type.

Data Termination - Shows data’s termination.

Audio Input Level - (Only in CRT) Shows audio input’s status.

Audio Input Inmpedance - (Only in CRT) Shows audio input impedance.

Transmitter Status Listing

----------------------------------------------------------

Supply Voltage.......... 11.9 V

Module Temperature...... 33.5 Cels.

Hours:Mins.............. 1122:18

Module Address.......... 0000...FFFF

Module Status........... OK / HW Failure

Delay Between Bytes..... 0...100 ms

CH1..................... Video Present / NO Video / Disabled

CH2..................... Video Present / NO Video / Disabled

CH3..................... Video Present / NO Video / Disabled

CH4..................... Video Present / NO Video / Disabled

Data Type............... RS422/TTL

Data Termination........ None/Hardbias/Hardbias+Term

Audio Input Level....... OK / Input Overload

Audio Input Impedance... 600 ohms/High

CC1 / Vid Src Alarm..... CC1/VSA

CC1 Input............... Open/Closed

----------------------------------------------------------

Picture 6.

Transmitter’s “status” info view/settings.

Receiver Status Listing

----------------------------------------------------------

Supply Voltage.......... 12.0 V

Module Temperature...... 37.5 Cels.

Hours:Mins.............. 1122:14

Module Address.......... 0000...FFFF

Link Status............. OK / No Sync or Optical Input Low

Module Status........... OK / HW Failure

Delay Between Bytes..... 0...100 ms

CH1..................... Video Present / NO Video / Disabled

CH2..................... Video Present / NO Video / Disabled

CH3..................... Video Present / NO Video / Disabled

CH4..................... Video Present / NO Video / Disabled

Data Type............... RS422/TTL

Data Termination........ None/Hardbias/Hardbias+Term

CC1 / Vid Src Alarm..... CC1/VSA

CC1 Output.............. Open/Closed

----------------------------------------------------------

Picture 7.

Receiver’s “status” info view/settings.

Management Software for CFO401/431/451 Units User Manual rev001 5

CFO401/431/451 INFO CODES

00 No Info code

01 DVX Write buffer full

02 DVX Write buffer empty

03 DVX Read no packet

04 DVX Read too long packet

05 DVX Checksum error in read packet

06 DVX Wrong address

07 DVX General info

10 FPGA IRQ over fl ow

11 Edge Tracking

12 Transmitter Laser Disabled

13 Debug version

14 UART0 Rx ring full

15 FPGA Tx ring full

16 FPGA Rx ring full

17 UART0 Tx ring full

18 Laser restart

19 Resyncronization

20 EMS Too long packet

21 EMS Unknown type of packet

22 EMS Unknown Element ID

23 EMS Unknown command

30 Too long command for Action Direct

32 E2 storage error

90 No alarm for info codes above this

97 Action Direct, bad command

98 Info Code manually cleared

99 Big Bang, stands for power up

6 Management Software for CFO401/431/451 Units User Manual rev001

CFO Backplane Euro Connector

a -- c

COAX ()

COAX ()

+12VDC o 07 o +12VDC

GND o 08 o GND

BB-BUS+ o 09 o BB-BUS-

GND o 10 o GND

EIA485+ o 11 o EIA485- DVX BUS

SDA DATA o 12 o SCL CLOCK

YY4 ID L o 13 o YY1 IC L244

YY3 SM L o 14 o YY2 PR L244

- o 15 o -

- o 16 o -

- o 17 o -

- o 18 o -

- o 19 o -

YY60 1+ o 20 o YY62 1- L244

A-ALARM BUS o 21 o B-ALARM BUS

YY59 2- o 22 o YY63 2+ L244

YY58 3+ o 23 o YY624 3- L244

YY57 TP1 o 24 o YY61 TP2 L244

AA A-ALARM o 25 o B-ALARM AB

C1 CTRL-1 o 26 o CTRL-2 C2

COAX ()

COAX ()

DEMO NUMBERS for CFO401/431/451 simulations and testing

Note! Unit will return from demo mode to normal operation mode automatically after one hour.

00 No Demo, Default (also demo interrupt)

03 ** Video Detection Demo, All Channels

05 * Temperature Demo

08 * Power Supply #1 Demo

21 CC1 Input Close State Demo

31 ** Video Detection Demo Ch #1

32 ** Video Detection Demo Ch #2

33 ** Video Detection Demo Ch #3

34 ** Video Detection Demo Ch #4

58 * Temperature & Power Supply #1 Demo

* This Demo Uses Test Value.

** Video Leds In Transmitter Not Affected

Management Software for CFO401/431/451 Units User Manual rev001 7

Copyright Acknowledgements

Information in this document is subject to change without notice and does not represent a commitment on the part of Teleste Corporation.

Copyright © 2000 - 2002 Teleste Corporation. All Rights Reserved.

No part of this document may be reproduced, transmitted, stored in a retrieval system, or translated into any other language without the express permission of Teleste Corporation.

Teleste Corporation

Video Networks

P.O. Box 323

FIN-20101 Turku

FINLAND www.teleste.com/cctv

8 Management Software for CFO401/431/451 Units User Manual rev001

Management Software for CFO401/431/451 Units User Manual rev001 9

advertisement

Key Features

  • Management software for configuration
  • Serial data communication via RS232
  • Uni-directional communication via fiber
  • Status telemetry via fiber
  • Remote control of CRR unit from CRT
  • Factory settings reset
  • Alias naming
  • Software version and hardware information display
  • Info code explanations for link status

Frequently Answers and Questions

How do I make the terminal connection to the CFO400 series fiber optic link?
Connect a RS232 cable (CIC403) between the CFO unit and a PC or PSION. Configure the COM port settings for VT100/102 or ANSI protocol, 19200 baud rate, 8 data bits, no parity, 2 stop bits, and no flow control.
What commands are available in the management software?
The management software provides commands for checking status, changing settings, resetting the CPU, and entering demo mode. Use the 'help' or '?' command to see a list of all available commands.
How do I set the default factory settings?
Use the 'factoryset' command to reset the unit to its default configuration.