Below you will find brief information for Fiber Optic Link CFO400 CFO401, Fiber Optic Link CFO400 CFO431, Fiber Optic Link CFO400 CFO451. This manual describes how to configure the settings of the CFO400 series fiber optic link for use with a CRT401/431/451 and CRR401/431 units. The manual provides instructions on making the terminal connection to the device, using the management software commands to configure and control the units, and troubleshooting common issues. The document also includes information on the CFO Backplane Euro Connector and demo numbers for simulation and testing.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
CFO400 Series
MANAGEMET SOFTWARE FOR
CFO401/431/451 UNITS
CFO400sw1 User Manual, 59300066, rev001
Contents
Introduction ........................................................................................................................... 1
Management Software for CFO401/431/451 Units .............................................................. 2
General ........................................................................................................................... 2
System Requirements .................................................................................................... 2
How to Make the Terminal Connection ........................................................................2-3
Management Software Commands ................................................................................ 3
CFO401/431/451 Help View...................................................................................... 3
Description of Commands......................................................................................... 4
Description of Status Listing ..................................................................................... 4
Transimitter’s Status Listing View .............................................................................. 5
Receiver’s Status Listing View .................................................................................. 5
CFO401/431/451 Info Codes ................................................................................................. 6
CFO Backplane Euro Connector .......................................................................................... 7
Demo Numbers for CFO401/431/451 Simulations and Testing ......................................... 7
Copyright Acknowledgements ............................................................................................. 8
Management Software for CFO401/431/451 Units User Manual rev001
Management Software for CFO401/431/451
Units (SW version 1.1.23 -->)
Introduction
Management connection between CFO400 series fi bre optic link units and e.g. laptop or PSION is based on a serial data communication by means of any terminal type program.
Management software for CFO400 series fi bre optic link units
(v1.1.23 -->) is a Command Line Interface type and it is meant for confi guration and controlling of CFO401/431/451 link units
(uni-directional communication via fi bre, CRT --> CRR).
Local mgmt
CRT401/431/451
Transmitter
Uni-directional (CRT --> CRR)
remote mgmt and CRT status telemetry via fibre
CRR401/431
Receiver
Local mgmt
Management Software for CFO401/431/451
Series Units (SW version 1.1.23 -->).
Picture 1.
Naming a terminal connection.
Picture 2.
Selecting COM port.
Picture 3.
Settings for COM port.
GENERAL
This chapter tells how with help of management software you can confi gure settings of CFO400 series fi bre optic link consisting of CRT401/431/451 and CRR401/431 units.
SYSTEM REQUIREMENTS
* Any program using serial port communication and supporting VT100 / 102 or ANSI protocols, e.g. Windows
95/98 or Windows NT 4.0/2000/XP, PSION.
* RS232-cable (type CIC403). See table 1 for cable pinouts.
1. HOW TO MAKE THE TERMINAL CONNECTION
PC/PSION
Receive data
Transmit data
System ground
D9 female
2
3
5
HD15 male
2
12
15
CFO
Mgmt output
Mgmt input
Ground
Table 1.
Management cable (CIC403) pinouts (D9 female / HD15 male).
1. Start the Windows hyper terminal program (in Windows
95/98 and NT 4.0/2000/XP by choosing -> Start/
Programs/Accessories/Communications/Hyper Terminal).
Wait until the following “Connection Description” window appears on the screen (see picture 1).
2. Enter a name for connection, e.g. “CFO400 Terminal” and click OK to continue.
screen (see picture 2).
3. Choose COM port where the RS232 cable is connected, e.g. COM1 port and click OK to continue.
the screen (see picture 3). Set here the values as described in table 1. Click OK to continue. The
“CFO400 Terminal” window appears on the screen (see picture 4).
4. Press Enter to activate terminal window (“AD->” appears on the screen, see picture 4). The terminal connection to CFO401/431/451 unit is now created and you can now use the management commands to controlling the unit.
2 Management Software for CFO401/431/451 Units User Manual rev001
When the management software is activated,
“AD->” text appears on the screen.
Setting Value
VT102 ANSI
Protocol Serial
Baud rate 19200
Data bits 8
Parity None
Stop bits 2
Flow control None
Table 1.
Port settings to terminal connection.
Picture 4.
The Windows Hyper terminal program window.
2. MANAGEMENT SOFTWARE COMMANDS
After making and starting the terminal connection for the
CFO401/431/451 unit it is possible with help of separate commands of management software e.g. check the status or change the settings of CRT401/431/451 and CRR401/431 units. Entering help or ? displays a list of commands (see picture 5).
**************( Teleste Action Direct Help )***************
-----------------------------------------------------------
Help/?....... Help | Reset CPU..... Reset CPU
<Tab>........ Prev. command |
<Esc>........ Clear Line | speed ........ 0 - 100 ms
| video[n] ..... 1 - 4 On/Off
status....... Status, Local |
| datatype ..... RS422/TTL
| dataterm ..... None/Hardbias/Hardbias+Term
| audio ........ 600/High
alias ....... Element Name | cc1=vsa....... CC out = Video Source Alarm
vers......... SW Version | cc1=off....... CC out = Off
demonr #..... Set Demo Mode | factoryset.... Defaults
tv .......... Set Test Value |
-----------------------------------------------------------
Picture 5.
CFO401/431/451 “help” view.
Management Software for CFO401/431/451 Units User Manual rev001 3
2.1. Description of commands
Note! Remote commands can be sent only from CRT to
CRR via fi bre. Due to one-way operation no replies are received from CRR to CRT.
help / ? - Displays a list of commands.
rc [command] [value] - Remote command (only from CRT to
CRR!) e.g. changing CRR’s audio to high -> rc audio high.
status - (when cable is connected to CRT) Displays a status of CRT unit (see picture 6).
status - (when cable is connected to CRR) Displays a status of CRR unit (see picture 7).
status rc - (when cable is connected to CRR) Displays a status of CRT unit (see picture 6).
factoryset - Sets default factory settings.
alias [name] - Alias naming (the maximum is 32 characters).
vers - Displays application software version, alias name, hardware version and serial number of the local unit.
about - Additional information displays. Includes e.g. info code explanations describing the link status (during malfunction info codes are echoed to the prompt).
reset cpu - Resets cpu (same effect as taking power off).
chat [value] - Displays max 40 chr text (only from CRT to CRR).
speed [0-100] - The value (ms) defi nes speed that terminal’s text is printed on the screen.
datatype [value] - Changes datatype settings.
dataterm [value] - Changes dataterm settings.
audio [value] - Changes audio input settings.
cc1=vsa - Changes cc output channel to video source alarm.
cc1=cc1 - Changes video source alarm to cc output channel.
4 Management Software for CFO401/431/451 Units User Manual rev001
2.2. Description of status listing
Supply voltage - Shows unit’s supply voltage.
Module Temperature - Shows unit’s internal temperature.
Hours:Mins, local - Unit’s usage hour meter.
Module address - Shows slot where the unit is installed (not in use).
Link Status - Shows link’s status
Module Status - Shows module’s status.
Delay between bytes - Shows terminal’s display speed.
CH1, 2, 3 & 4 - Shows video’s status.
CC / Vid Src Alarm - Shows cc output channel’s status.
Data Type - Shows data’s type.
Data Termination - Shows data’s termination.
Audio Input Level - (Only in CRT) Shows audio input’s status.
Audio Input Inmpedance - (Only in CRT) Shows audio input impedance.
Transmitter Status Listing
----------------------------------------------------------
Supply Voltage.......... 11.9 V
Module Temperature...... 33.5 Cels.
Hours:Mins.............. 1122:18
Module Address.......... 0000...FFFF
Module Status........... OK / HW Failure
Delay Between Bytes..... 0...100 ms
CH1..................... Video Present / NO Video / Disabled
CH2..................... Video Present / NO Video / Disabled
CH3..................... Video Present / NO Video / Disabled
CH4..................... Video Present / NO Video / Disabled
Data Type............... RS422/TTL
Data Termination........ None/Hardbias/Hardbias+Term
Audio Input Level....... OK / Input Overload
Audio Input Impedance... 600 ohms/High
CC1 / Vid Src Alarm..... CC1/VSA
CC1 Input............... Open/Closed
----------------------------------------------------------
Picture 6.
Transmitter’s “status” info view/settings.
Receiver Status Listing
----------------------------------------------------------
Supply Voltage.......... 12.0 V
Module Temperature...... 37.5 Cels.
Hours:Mins.............. 1122:14
Module Address.......... 0000...FFFF
Link Status............. OK / No Sync or Optical Input Low
Module Status........... OK / HW Failure
Delay Between Bytes..... 0...100 ms
CH1..................... Video Present / NO Video / Disabled
CH2..................... Video Present / NO Video / Disabled
CH3..................... Video Present / NO Video / Disabled
CH4..................... Video Present / NO Video / Disabled
Data Type............... RS422/TTL
Data Termination........ None/Hardbias/Hardbias+Term
CC1 / Vid Src Alarm..... CC1/VSA
CC1 Output.............. Open/Closed
----------------------------------------------------------
Picture 7.
Receiver’s “status” info view/settings.
Management Software for CFO401/431/451 Units User Manual rev001 5
CFO401/431/451 INFO CODES
00 No Info code
01 DVX Write buffer full
02 DVX Write buffer empty
03 DVX Read no packet
04 DVX Read too long packet
05 DVX Checksum error in read packet
06 DVX Wrong address
07 DVX General info
10 FPGA IRQ over fl ow
11 Edge Tracking
12 Transmitter Laser Disabled
13 Debug version
14 UART0 Rx ring full
15 FPGA Tx ring full
16 FPGA Rx ring full
17 UART0 Tx ring full
18 Laser restart
19 Resyncronization
20 EMS Too long packet
21 EMS Unknown type of packet
22 EMS Unknown Element ID
23 EMS Unknown command
30 Too long command for Action Direct
32 E2 storage error
90 No alarm for info codes above this
97 Action Direct, bad command
98 Info Code manually cleared
99 Big Bang, stands for power up
6 Management Software for CFO401/431/451 Units User Manual rev001
CFO Backplane Euro Connector
a -- c
COAX ()
COAX ()
+12VDC o 07 o +12VDC
GND o 08 o GND
BB-BUS+ o 09 o BB-BUS-
GND o 10 o GND
EIA485+ o 11 o EIA485- DVX BUS
SDA DATA o 12 o SCL CLOCK
YY4 ID L o 13 o YY1 IC L244
YY3 SM L o 14 o YY2 PR L244
- o 15 o -
- o 16 o -
- o 17 o -
- o 18 o -
- o 19 o -
YY60 1+ o 20 o YY62 1- L244
A-ALARM BUS o 21 o B-ALARM BUS
YY59 2- o 22 o YY63 2+ L244
YY58 3+ o 23 o YY624 3- L244
YY57 TP1 o 24 o YY61 TP2 L244
AA A-ALARM o 25 o B-ALARM AB
C1 CTRL-1 o 26 o CTRL-2 C2
COAX ()
COAX ()
DEMO NUMBERS for CFO401/431/451 simulations and testing
Note! Unit will return from demo mode to normal operation mode automatically after one hour.
00 No Demo, Default (also demo interrupt)
03 ** Video Detection Demo, All Channels
05 * Temperature Demo
08 * Power Supply #1 Demo
21 CC1 Input Close State Demo
31 ** Video Detection Demo Ch #1
32 ** Video Detection Demo Ch #2
33 ** Video Detection Demo Ch #3
34 ** Video Detection Demo Ch #4
58 * Temperature & Power Supply #1 Demo
* This Demo Uses Test Value.
** Video Leds In Transmitter Not Affected
Management Software for CFO401/431/451 Units User Manual rev001 7
Copyright Acknowledgements
Information in this document is subject to change without notice and does not represent a commitment on the part of Teleste Corporation.
Copyright © 2000 - 2002 Teleste Corporation. All Rights Reserved.
No part of this document may be reproduced, transmitted, stored in a retrieval system, or translated into any other language without the express permission of Teleste Corporation.
Teleste Corporation
Video Networks
P.O. Box 323
FIN-20101 Turku
FINLAND www.teleste.com/cctv
8 Management Software for CFO401/431/451 Units User Manual rev001
Management Software for CFO401/431/451 Units User Manual rev001 9
advertisement
Key Features
- Management software for configuration
- Serial data communication via RS232
- Uni-directional communication via fiber
- Status telemetry via fiber
- Remote control of CRR unit from CRT
- Factory settings reset
- Alias naming
- Software version and hardware information display
- Info code explanations for link status