- Home
- Domestic appliances
- Climate control
- Weather stations
- Oregon Scientific
- BAR339DP
- User manual
- 11 Pages
Oregon Scientific BAR339DP User manual
Oregon Scientific BAR339DPU is a weather station with a digital clock that projects the time, outdoor temperature, and weather forecast. It can also track indoor/outdoor temperatures and display them with a selectable unit (°C/°F). The weather forecast feature provides a 12-24 hour prediction with 75% accuracy within a 30-50 km radius.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
▼
Scroll to page 2
of
11
'breGon SCIENTIFIC Weather Day & Night Model: BAR339DP I BAR339DPA I BAR339DPU I BAA339DPH USER MANUAL Remote RF Clock Thermo Sensor ............................8 Precautions .......................................................................8 About Oregon Scientific ...............................................9 USER MANUAL EU-Declaration of Conformity ....................................9 FCC Statement .................................................................9 CONTENTS Declaration of Conformity ........................................ 10 Overview ............................................................................2 Front View .......................................................................2 Back View .......................................................................3 Remote Sensor .............................................................3 Getting Started.................................................................3 Main Unit Installation ....................................................3 Remote Sensor Installation ........................................4 Clock ...................................................................................5 Clock Reception ............................................................5 Manually set Clock .......................................................6 Alarm ...................................................................................6 Weather Forecast ............................................................6 Temperature .....................................................................7 Projection ..........................................................................7 Backlight ............................................................................7 Reset ...................................................................................7 Specifications ..................................................................8 1 EN Main Unit .........................................................................8 Weather Day & Night Model: BAR339DP I BAR339DPA I BAR339DPU I BAA339DPH display; activate I deactivate auto-scan OVERVIEW 11 . .Wnit batteries low I no battery 12. Projector: Proj ect time I outdoor temperature and w eather forecast FRONT VIEW ~-------- 11 ~ ~--- 1 2 13. rilcate indoor I outdoor sensor reception status 14. Outdoor Temperature (Current I Max I Min) 15. Clock 16. Time Zone Offset 17. Calendar w ith w eekday I seconds 18. ALARM : View alarm status I set alarm 19. MEM: Toggle betw een current I maximum minimum temperature display; clear records 2 13 14 15 16 17 9 10 18 - - - - - -19 1. SNOOZE: Activate snooze alarm; turn on backlight; flip proj ected image 180° 2 . Weather forecast 3. 6.'W Outdoor remote sensor battery low 'b 4. Radio controlled clock reception icon 5. PM: Indicates PM (12 hour mode) 6. (<•>)Indicate alarm time is displayed 7. ~Indicate daily alarm is On 8. PM: Indicates PM (12 hour mode) 9. CLOCK: Change display; set clock 10. TEMP :Togglebetween indoorloutdoortemperature 2 I 9. Battery compartment FRONT VIEW BACK VIEW 1---THERMO• RF C\.OCK SENSOR 1. FOCUS Wheel : Adjust projection focus 2. ACIDCAdaptorsocket 3. S crease I increase value of the setting; enable I disable clock reception 4 . SEARCH : Initiate sensor search 5. OC I OF: Select temperature unit 6. LIGHT ONIOFF: Turn backlight continuously On (adaptor installed) I only when SNOOZE key is pressed 7. RESET: Reset unit to default settings 8. PROJECTION OFF- CLOCK - AUTO : Select projection display 1. 2. 3. 4. 5. 6. A: RESET: Reset unit to default settings EU I UK Sw itch (RTHN318D sensor only) Channel Switch Double sided adhesive tape Wall mount hole Batterycompartment GETTING STARTED Batteries serve as a back-up pow er supply. For continuous use of projector and backlight, install adapter. 3 I · Plug ACIDC adaptor into socket. Make sure the adapter is not obstructed and is easily accessible to the unit. The sensor recept io n icon show s t he status : ICONS To completely disconnect from power, the adapter should be disconnected from the main unit. MEANING Main unit is searching for sensor(s) NOT The main unit and adapter should not be exposed to wet conditions. No objects filled with liquid, such as vases, should be placed on the main unit and adapter. 1 A sensor channel has been found and logged on Memory backup: 1. Remove the battery compartment cover. 2 . Insert the batteries, matching the polarities. No sensor found OTE Batteries should not be exposed to excessive heat such as sunshine or fire. NOTE After every sensor initialisation, the main unit may take up to 30 minutes to receive the time from the sensor. REMOTE SENSOR INSTALLATION 1. 2. 3. 4. 5. 6. 7. Slide open the battery door. Slide channel sw itch to channel 1. Select EUIUK. (RTHN3 18D only) Insert the battery, matching the polarities(+ 1-). Press RESET after each battery change. Close the battery door. Press and hold SEARCH on main unit to initiate search and start receiving time and temperature data from the sensor. 8. Secure the sensor in the desired location using the wall mount hole or double sided adhesive tape. 4 ,.. NOTE Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing. ~ ,--- o..-- I ·~ c CLOCK ~ CLOCK RECEPTION .. .......... • Q This product is designed to synchronize its clock automatically w ith a clock signal received from provided remote sensor. _J To enable I disable signal receptio n: Press and hold to enable or to disable signal reception. A Fo r b est results: Place the sensor w ithin 30 m ( 100 ft) of the main unit. Place the sensor out of direct sunlight and moisture. Posit ion the sensor so that it faces the main unit, minimizing obstructions such as doors, w alls and furniture. Place the sensor in a location w ith a clear view to the sky, aw ay from metallic I electronic objects. Posit ion the sensor close to the main unit during cold w inter months as below -freezing temperatures may affect battery performance and signal transmission . T NOTE Reception takes 2-10 minutes. If the signal is w eak, it can take up to 24 hours to get a valid signal. Clock s ignal recept io n indic ator: STRONG SIGNAL WEAK I NO SIGNAL NOTE Clock reception is dependent on the successful transmission of data from remote sensor. If ~ is displayed , press RESET on sensor and press A and ~ T on the main unit and ensure sensor ,_:_, has been l!!!!!J successf ully logged. iTIP. The transmission range may vary depending on many factors. You may need to experiment w ith various locations to get the best results. 5 I I 3. Press ALARM to confirm . ~ indicates alarm is on. MANUALLY SET CLOCK To set the clock manually, disable the clock signal reception first. 1. Press and hold CLOCK. 2. Press .A.1 Y to change the settings. 3. Press CLOCK to confirm. To activate I deactivate alarm: 1. Press ALARM to display alarm time. 2. Press ALARM again to turn alarm on I off. To silence the alarm: • Press SNOOZE to silence it for 8 minutes OR • Press any key to turn the alarm off and activate it again after 24 hours. The settings order is: time zone, 12124 hr format, hour, minute, year, calendar mode (month - day I day - month), month, day and language. BAR339DP: Time zone offset sets the clock +I- 23 hours from the received clock signal time. WEATHER FORECAST NOTE If you enter+ 1 in the time offset setting, this will give you your local time plus one hour. If you are in the US (BAR339DPAonly) set the clock to: 0 for Pacific time +2 for Central time This product forecasts the next 12 to 24 hours of weather within a 30-50 km (19-31 mile) radius with a 75% accuracy. +1 for Mountain time +3 for Eastern time Main unit Projector -¢- Sunny qJ- Partially Cloudy To select clock display mode: Press CLOCK to toggle between clock with seconds, clock w ith weekday. C)C) Cloudy ALARM ~<;? Rainy ~*: ·+ Snowy NOTE The language options are English (E), Spanish (S), Italian (I), French (F), German (D), and Russian (R). To set the alarm: 1. Press qpd ~d ALARM . 2. Press A I T to change the settings. 6 - To project weather forecast and time: Press SNOOZE when PROJECTION switch is in OFF mode To toggle between indoor I outdoor temperature display: Press TEMP. OR To toggle temperature unit: Press 0C I 0F. Slide PROJECTION switch to CLOCK mode for continuous display. To auto-scan between sensors: Press and hold TEMP. To project weather forecast and activate toggling display of time I outdoor temperature: Slide PROJECTION switch to AUTO mode. To deactivate auto-scan function: Press TEMP. To deactivate projection: Slide PROJECTION switch to OFF mode. To toggle between current, minimum and maximum records for indoor I outdoor: Press MEM repeatedly. To focus image: Turn FOCUS wheel. NOTE If projection is illuminated, do not look directly into the projector. To clear records: Press and hold MEM. BACKLIGHT PROJECTION To activate continuous backlight: • Slide LIGHT - ON I OFF switch to ON. This unit projects time, outdoor temperature information and weather forecast for your convenience. To deactivate continuous backlight: • Slide LIGHT - ON I OFF switch to OFF (Press SNOOZE to activate LED backlight for 5 seconds). NOTE Install adapter to use projection feature. To lip projected image by 1800: Press SNOOZE. RESET Press RESET to return to the default settings. 7 EN TEMPERATURE EN SPECIFICATIONS PRECAUTIONS • MAIN UNIT TYPE DESCRIPTION LxWxH 142 x 42 x 158 mm (5.59 x 1.65 x 6.22 in) Weight 270g (9.52 oz) without battery Power 5V AC adaptor 2 x CR2032 batteries (for backup) • • • • • • REMOTE RF CLOCK THERMO SENSOR • TYPE DESCRIPTION LxWxH 64 x 25 x 98 mm (2.52 x 0.98 x 3.86 in) Weight 80 g (2.8 oz) without battery Temperature range -20°C to 60°C (-4°F to 140°F) Resolution 0.1°C (0.2°F) • Signal frequency 433 MHz • Transmission range 30 m (98 ft) unobstructed No. of channels 5 Power 1 x UM-3 (AA) 1.5 V batteries • • 8 Do not subject the unit to excessive force, shock, dust, temperature or humidity. Do not cover the ventilation holes with any items such as newspapers, curtains etc. Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth. Do not clean the unit with abrasive or corrosive materials. Do not tamper with the unit's internal components. This invalidates the warranty. Only use fresh batteries. Do not mix new and old batteries. Images shown in this manual may differ from the actual display. When disposing of this product, ensure it is collected separately for special treatment and not as normal household waste. Placement of this product on certain types of wood may result in damage to its finish for which Oregon Scientific will not be responsible. Consult the furniture manufacturer's care instructions for information. The contents of this manual may not be reproduced without the permission of the manufacturer. Do not dispose old batteries as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. Please note that some units are equipped with a battery safety strip. Remove the strip from the battery compartment before first use. ! CE NOTE The technical specifications for this product and the contents of the user manual are subject to change without notice. Ro HS COMP LI ANT COUNTRIES RTTEAPPROVALCOMPLIED A ll EU countries, Sw itzerland@ and Norway® NOTE Features and accessories w ill not be available in all countries. For more information, please contact your local retailer. FCC STATEMENT ABOUT OREGON SCIENTIFIC This device complies with Part 15 of the FCC Rules. Operation is subject to the follow ing tw o conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received , including interference that may cause undesired operation. V isit our w ebsite (www.oregonscientific.com) to learn more about Oregon Scientific products. If you're in the US and w ould like to contact our Customer Care department directly, please visit: www2 .oregonscientific.comlservicelsupport.asp For international inquines, please visit: www2 .oregonscientific.comlaboutlinternational .asp WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. EU-DECLARATION OF CONFORMITY NOTE This equipment has been tested and found to comply w ith the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation . Hereby, Oregon Scientific, declares that this Weather Day & Night (Model: BAR339DP I BAR339DPA I BAR339DPU I BAA339DPH ) is in compliance with the essential requirements and other relevant provisions of Directive 1999151EC . A copy of the signed and dated Declaration of Conformity is available on request via our Oregon Scientific Customer Service. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance w ith the instructions, may cause harmful interference to radio communications. How ever, there is no guarantee that interference w ill not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, 9 I EN which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio I TV technician for help. Manufacturer: Address: IDT Technology Limited Block C, 9IF, Kaiser Estate, Phase 1, 41 Man Yue St., Hung Hom, Kowloon, Hong Kong is in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation. DECLARATION OF CONFORMITY The following information is not to be used as contact for support or sales. Please visit our website at www2. oregonscientific.comIservice for all enquiries. We Name: Address: Telephone No.: Oregon Scientific, Inc. 19861 SW 95th Ave.,Tualatin, Oregon 97062 USA 1-800-853-8883 declare that the product Product No.: BAR339DP I BAR339DPA I BAR339DPU I BAA339DPH Product Name: Weather Day & Night 10
advertisement