tvONE 2620030-04 MVII AK1200DP-SAP, 2620006-02 MV II AK600DP-A, 2620019-04 MV II AK600DP-SAP, 2620018-03 MVII AK600DP-SAP, 2620018-04 MVII AK600DP-SAP, 2620009-03 MVII AK1200DP-A, 2620006-03 MV II AK600DP-A, 2620009-02 MVII AK1200DP-A User manual

tvONE 2620030-04 MVII AK1200DP-SAP, 2620006-02 MV II AK600DP-A, 2620019-04 MV II AK600DP-SAP, 2620018-03 MVII AK600DP-SAP, 2620018-04 MVII AK600DP-SAP, 2620009-03 MVII AK1200DP-A, 2620006-03 MV II AK600DP-A, 2620009-02 MVII AK1200DP-A User manual
TM
MultiView II
AK600DP
AK1200DP
Receiver
Installation and User Guide
Version 1.00
2791 Circleport Drive, Erlanger, KY 41018, USA.
Americas: 859-282-7303
EMEA: +44 (0) 1843 873322
Email: [email protected]
www.tvone.com
PDF-UG-MVII-AK
Manual Copyright Notice
This document and the Magenta Research products to which it relates, and the copyright in each, is the
intellectual property of tvONE, ©2014. Neither the document nor the products may be reproduced by any
means, in whole or in part, without the express prior written permission of tvONE.
Disclaimer
tvONE makes no warranty or representation, either express or implied, with respect to this software or
documentation, including their quality, performance, merchantability, or fitness for a particular purpose. As a
result, this software or documentation are licensed "as is" and you, the licensee, are assuming the entire risk as
to their quality and performance.
In no event will tvONE be liable for direct, indirect, special, incidental, or consequential damages arising out of
the use of or inability to use the software or documentation.
Magenta Research and the Magenta Research logo are trademarks owned entirely by tvONE. All other brands,
product names, and trademarks are the property of their respective owners.
MultiView™ II AK600DP/AK1200DP Installation and User Guide
ii
Error! No text of specified style in document.
Precautions
Safety Instructions ● English
This symbol calls attention to important information.
This symbol alerts the user of important maintenance (or servicing) and operating information.
This symbol alerts the user to the presence of un-insulated dangerous voltages or other conditions in, or
around, the product enclosure. These conditions can present a risk of electric shock or damage to
equipment or facilities.
Connection • Not for direct connection to Telecommunication Network Circuitry (TNV)
Power sources • This equipment should be operated only from the power source indicated on the product.
Disconnect all power sources before servicing.
Power disconnection • To remove power from the equipment safely, remove all power cords from the rear of
the equipment, or from the power source receptacle (wall plug).
Power cord protection • Power cords should be routed so that they are not likely to be stepped on or pinched
by items placed upon or against them.
Servicing • Refer all servicing to qualified service personnel.
Slots and openings • If the equipment has slots or holes in the enclosure, these are provided to prevent
overheating of sensitive components inside. These openings must never be blocked by other objects.
Caution:
Read Instructions: Read and understand all operating, installation, and safety instructions before using this
equipment.
Avoid Attachments: Only use accessories, attachments, tools, and materials that are recommended by the
equipment manufacturer. Doing otherwise can compromise operating performance, create an unsafe condition,
damage equipment, or violate the terms of usage or warranty.
Follow Warnings: Always follow all instructions and warnings marked on the equipment or as detailed in
related users’ guides.
MultiView™ II AK600DP/AK1200DP Installation and User Guide
iii
Error! No text of specified style in document.
Table of Contents
Page
Chapter 1
About this Manual ...................................................................................................................... 1
Chapter 2
Product Overview ....................................................................................................................... 2
2.1
Front Panel Interfaces ..................................................................................................... 2
2.2
Rear Panel Interfaces ..................................................................................................... 3
Chapter 3
Specifications ............................................................................................................................. 4
3.1
General Specifications .................................................................................................... 4
3.2
Twisted-Pair Cable Compatibility .................................................................................... 5
Chapter 4
Installation .................................................................................................................................. 6
4.1
Option-Module Configuration .......................................................................................... 6
4.2
Prerequisites ................................................................................................................... 6
4.3
Installation Procedure ..................................................................................................... 7
4.4
Adjustments .................................................................................................................... 9
4.4.1
Cable Distance (EQ) Compensation Settings................................................. 9
4.4.2
Skew Compensation Settings ....................................................................... 10
4.5
Configuration Settings ................................................................................................... 11
4.5.1
Configuration Modes 1 & 2 ........................................................................... 11
4.5.2
Sync-mode Settings (LED1-2) ...................................................................... 12
4.5.3
4th Pair Settings (LED4-6) ............................................................................. 13
4.5.4
Vsync Polarity Settings (LED7)..................................................................... 14
4.5.5
Hsync Polarity Settings (LED8) .................................................................... 14
4.5.6
Clamp-mode Settings (CFG2: LED1-2) ........................................................ 15
4.5.7
4th Pair Termination Settings (CFG2: LED3) ................................................ 16
Chapter 5
Troubleshooting ....................................................................................................................... 17
Chapter 6
Connector Pinouts ................................................................................................................... 19
Appendix A
Skew Module Installation ......................................................................................................... 24
Appendix B
(SAP) Option Module Settings ................................................................................................. 25
Appendix C
Pollable Serial Mode Address Chart ........................................................................................ 26
Appendix D
Mounting Kits ........................................................................................................................... 28
Appendix E
System Design Drawings ......................................................................................................... 30
MultiView™ II AK600DP/AK1200DP Installation and User Guide
iv
About this Manual
Chapter 1
About this Manual
This manual describes the Magenta MultiView™ II AK600DP and AK1200DP receivers, and contains the
following information:





Product overview (Chapter 2)
Product specifications (Chapter 3)
Installation and configuration instructions (Chapter 4)
Troubleshooting (Chapter 5)
Additional information (Appendices)
The Magenta MultiView™ II family (MVII) of products introduces greater compatibility for handling HD video
standards, as well as making nearly all user-configurable options “jumperless” via a digital front-panel userinterface.
Note: MultiView II products are fully backwards-compatible with previous MultiView products. Combining MVII
with original MV products may limit access to some of the improved capabilities of the MVII series, so for best
possible compatibility with sources and displays, always try to use MVII products throughout your system
configuration.
The following table shows the factory-configured versions of the MVII-AK600(1200)DP.
Table 1: Available MVII-AK600(1200)DP Versions
Version
Description
MVII-AK600(1200)DP-S/A
Supports L+R summed audio or simplex serial (user-configuration setting).
MVII-AK600(1200)DP-SAP
Supports 3-wire RS-232 serial (simplex or duplex), and true stereo audio.
The serial feature is POLLABLE, so that multiple receivers on a daisychained link can be addressed individually for display control or statusquery.
Contains the (SAP) option module.
Note:
1.
2.
Each of the above variants is also available with the AkuComp-II skew-compensation module installed.
The –S/A version is also field-configurable for S/PDIF digital audio extension on the 4th-pair.
This equipment is not intended for, nor does it support, distribution through an Ethernet
network. Do not connect these devices to any sort of networking or telecommunications
equipment.
Use only approved MultiView™ II power adapters. Failure to do so may damage this device and
will void the warranty.
CHAPTER 3: SETUP & INSTALLATION
MultiView™ II AK600DP/AK1200DP Installation and User Guide
1
Product Overview
Chapter 2
Product Overview
The MVII-AK600(1200)DP is a video receiver that is compatible with the entire MultiView™ family of products.
It extends an analog video signal over standard CAT cable (CAT5, 5x, 6, 7 etc). There are user-configurable
settings for video, audio, and serial options which can be controlled from the front panel.
The MVII-AK600(1200)DP features optional integrated skew compensation that can be varied in 2 ns
increments to 65 ns total per color-channel to cancel the effects of skew in Category cables. This feature allows
you to use CAT5e and reduced-skew CAT6 cables to lengths up to 600ft (186m) for AK600DP, or 1200ft
(366m) for AK1200DP.
All models support video refresh rates/resolutions up to 1920x1200 to 600 feet (183m) with the AK600DP, and
1200ft (366m) with the AK1200DP.
2.1
Front Panel Interfaces
The front panel of the MVII-AK600(1200)DP has the following controls and indicators:
SKEW/SEL
button
Skew/EQ/Config
adjustment buttons
CFG/MODE
button
CFG
indicator
SKEW/SEL
indicator
EQ/SKEW
range indicators
Power-on
indicator
Figure 1: MVII-AK600(1200)DP Front Panel Interfaces
There are four buttons (CFG/MODE, SKEW/SEL, DOWN, and UP) and several LED status indicators. All are
used to display and control the operating modes of the receiver, with the LEDs having multiple functions. The
CFG indicator shows these modes:


In normal mode, the CFG indicator is off.
In configuration mode, the CFG indicator will be on or flashing.
MultiView™ II AK600DP/AK1200DP Installation and User Guide
2
Product Overview
2.2
Rear Panel Interfaces
The rear panel of the MVII-AK600(1200)DP has the following ports:
DB9 serial port
(optional, on SAP
model only)
Video output
to display
UTP (link)
input port
Auxiliary
signals
UTP (link)
output port
DC power
input port
Figure 2: MVII-AK600(1200)DP Rear Panel Interfaces
MultiView™ II AK600DP/AK1200DP Installation and User Guide
3
Specifications
Chapter 3
Specifications
This section describes the following specifications:


3.1
General specifications
Category cable compatibility
General Specifications
The following table lists the general specifications of the MVII-AK600(1200)DP.
Table 2: MVII-AK600(1200)DP General Specifications
Item
Description
Cable Required
Compliance
Video Support
Resolution &
Refresh Rate
Required source
impedance
Required
destination
impedance
Audio
Characteristics
Serial
Characteristics
Connectors
Temperature
Tolerance
Humidity Tolerance
Enclosure
Power
Size
Weight
Category 5, 5e, or 6 cable. Shielded or unshielded twisted pair. Low-skew.
CE; FCC Class A, IC Class A, UL listed I.T.E Device.
All supported VESA modes to WUXGA (1920x1200), RGBHV, RGsB, RGBs, Composite
(NTSC, PAL, SECAM), S-Video, Component Video, widescreen modes, HDTV modes
including 1080p, 1080i, 720p
MVII-AK600DP: At 600ft(183m) or less: a maximum of 1920x1200.
MVII-AK1200DP: At 1200ft(366m) or less: a maximum of 1920x1200.
Video OUT: 75 ohms
Audio models: Audio OUT (if any): capable of driving 10K ohms load.
SPDIF audio mode: 75 Ohm
Video IN: 75 ohms
Audio models: Audio IN (if any): 1K ohms minimum input impedance
SPDIF audio mode: 75 Ohm
(S/A) model: Right/Left summed, 50K input impedance, line level, unbalanced.
(SAP) models: Full stereo, 10K ohms input impedance, line level, unbalanced.
(S/A) model: Protocol: Asynchronous; transparent to data format; transparent to data
rates up to 115 kbps simplex.
(SAP) model: Protocol: Asynchronous; transparent to data format; transparent to data
rates up to 19.2 kbps full duplex or simplex (9 fixed baud rates are supported).
(1) 4 pin phoenix
(2) RJ-45 (1 input, 1 active loop-through)
(1) HD15 (F)
(1) DB9M (only if the SAP option module is installed)
(1) DC Power jack
Operating: 32 to 104°F (0 to 40°C)
Storage: -4 to +140°F (-20 to +60°C)
Up to 80% non-condensing
Steel, black powder-coat finish.
Input voltage: +5 VDC @ 1.2 Amps max.
Consumption: 6 watts maximum
1.2"H x 3.6"W x 5.5"D (3.0 x 9.2 x 14.0 cm)
1.0 lb. (0.45 kg)
MultiView™ II AK600DP/AK1200DP Installation and User Guide
4
Specifications
3.2
Twisted-Pair Cable Compatibility
MultiView products are compatible with Cat5/5e/6 data cabling, as well as “minimized skew” CAT5/5e cabling
(also referred to as “low-skew”) manufactured specifically for video applications. Follow these tips to ensure
proper usage of your Category cabling:

Some “low-skew” is specific to a particular vendor and is incompatible with our products. Ensure that
any “low-skew” cable is non-proprietary before purchase and installation.

CAT6 cable, due to the manufacture method, can exhibit much greater skew than standard CAT5/5e
and might require skew compensation beyond what the capabilities of the AkuComp-II option module
offers. Please contact tech-support for assistance.

Cabling for the Magenta MultiView™ Series must be pinned to the TIA-EIA T568B wiring specification.

We also highly recommend that all cables be pre-terminated and tested. Cables terminated on-site or
in an existing infrastructure should be tested before use to ensure compliance with the TIA-EIA T568B
specification. Using incorrectly terminated cables can damage the Magenta MultiView™ Series.

The cable should be suitably rated Listed cable ( DUZX ) communication cables, TYPE CMP, CMR,
CMG or CM as designated in the NEC.

Cables are to be installed in accordance with the NEC and local building and electrical codes. This is
the responsibility of the end user/installer of this product.
The following figure shows the T568B Wiring specification.
Figure 3: T568B pinout for RJ45 connectors and twisted-pair cables
MultiView™ II AK600DP/AK1200DP Installation and User Guide
5
Installation
Chapter 4
Installation
This section describes the following installation topics:





Data mode configuration
Prerequisites to installation
Installation procedure
Post-installation adjustments
Post-installation configuration settings
This equipment is not intended for, nor does it support, distribution through an Ethernet network.
Do not connect these devices to any sort of networking or telecommunications equipment!
Do not connect DC power until instructed to do so.
4.1
Option-Module Configuration
If you are installing a MVII-AK600(1200)DP-SAP version receiver (this is equipped with the SAP hardware
option module), then the following information will be important to review BEFORE installing the receiver:
The MVII-AK600(1200)DP-SAP version offers pollable RS232 duplex serial in addition to stereo audio. The
serial interface is 3-wire (TX, RX, GND) and does not support full modem signals. The factory-default serial
baud rate is 9600 baud, but this is a user-configurable option using “SAP-II” serial commands. Simplex modes
are supported without jumpers or other changes, by simply using the TX signal only. The SAP-module
capability of polling and interacting with specific receivers requires that each receiver have a unique address
setting. Please refer to Appendix-C for (SAP) module configuration information, and Appendix-D for SAPaddress settings. Setting this address involves opening your unit and setting DIP switches inside.
4.2
Prerequisites
Depending on the specific installation requirements, some common tools (screwdrivers, nut-drivers) and related
hardware (mounting screws) might be required. These are not provided with Magenta products.
The following items might be necessary, which are available from Magenta Research:



Audio cable: Phoenix 4-pin to RCA.
Video cable: HD15 connectors, or one of several BNC/RCA/S-Video breakout cables.
Serial cable: Phoenix 4-pin to DB9, or one of several DB9-M/F, M/M or F/F extension cables.
Note: You will need appropriate twisted-pair cable as previously described, to connect the MVIIAK600(1200)DP to other MultiView™ and MultiView™ II devices. tvONE does not supply Category cable.
MultiView™ II AK600DP/AK1200DP Installation and User Guide
6
Installation
4.3
Installation Procedure
Ensure that all connectors are clean and free of contaminants prior to making the
connections. Appropriate connector locking hardware (screws/latches) should be used to
prevent cables from disconnecting or causing intermittent operation.
All units must be the same type for 4th-pair supported features to function correctly. For
example, an “XRTx-A” must be connected to a MVII-AK600(1200)DP-A, as both must be
identical to work properly with L/R summed audio. Similarly, an “XRTx-SA” cannot be used
with an MVII-AK600(1200)DP-A”. Video modes may function normally, but 4th pair options
will not.
To install a typical MultiView transmitter (these steps are generic - refer to the appropriate MultiView
transmitter manual):
1.
Connect the source video to the Magenta MultiView™ transmitter video input port, which is an HD15
connector labeled SOURCE IN or VIDEO IN.
2.
If desired, attach a local monitor to the HD15 connector labeled LOCAL OUT (if available).
3.
Make your audio or serial connections via the phoenix connector or DB9 connector as appropriate.
4.
Connect the twisted-pair cable to the transmitter.
5.
Apply power to the transmitter.
a. The power-on LED should light up.
b. If there is a local monitor attached, a video image should appear on the
monitor.
MultiView™ II AK600DP/AK1200DP Installation and User Guide
7
Installation
To install the MVII-AK600(1200)DP receiver:
1.
Connect the VGA OUT connector to the display.
2.
Connect any audio and/or serial cables to the (AUX I/O) and (IOIO) connectors, depending on the
specific model of receiver you are installing. Please refer to the –S/A, –SAP option descriptions for
more information.
3.
Connect the twisted-pair cable from a MultiView transmitter to the LINK INPUT connector on the
receiver.
4.
If you are daisy-chaining multiple receivers, also connect the downstream twisted-pair cable to the
LINK OUTPUT port on the receiver.
5.
Connect the DC power cable to the POWER port, and check for the following indicators:

The power-on LED should light up (Green).

The CFG indicator is off.

The SKEW/RGB indicator is off.

The EQ/SKEW indicators display the current EQ settings (0 to 100%).
6.
IMPORTANT: Adjust the receiver’s EQ and/or SKEW (optional) settings for the best image.
7.
When the EQ setting is properly adjusted, the video should appear on the display (make sure display is
powered ON).
8.
Make any other required configuration changes via the LED/button user-interface.
It is critical that the EQ setting be adjusted to compensate for the length of the twisted-pair
cable leading back to the transmitter. Skew compensation adjustment (if your MVIIAK600(1200)DP is equipped with an AkuComp-II module) will also be important for best
image quality.


Connect the video out
HD15 connector to the
display device.

Connect the CAT cable
via the LINK INPUT port.

(Optional) Make your serial and/or audio
connections via the DB9 IOIO or AUX I/O
connectors, as appropriate. Refer to –S/A
and -SAP option descriptions.
(Optional) Connect the
output CAT cable via the
LINK OUTPUT port.

Connect the DC power
cable (+5VDC @ 2.6A.
max) to the POWER port.
Figure 4: MVII-AK600(1200)DP Receiver Installation Procedure
MultiView™ II AK600DP/AK1200DP Installation and User Guide
8
Installation
4.4
Adjustments
This section describes how to make the following adjustments:


4.4.1
Cable distance (EQ) compensation
Skew compensation
Cable Distance (EQ) Compensation Settings
When the MVII-AK600(1200)DP is operating in normal mode (CFG indicator is off), it is possible to quickly
adjust the EQ. The EQ/SKEW indicators 1-8 will change accordingly to show (in “bargraph” form) 0 to 100% of
the available EQ adjustment range (AK600DP = 0 to 600 ft, AK1200DP = 0 to 1200 ft).
For best results, use the Magenta EQ/Skew test pattern image if possible. A test pattern
image and video instructions is available at http://www.tvone.com.
The following figure shows the test image you can use to make the EQ adjustment.
Figure 5: EQ-adjustment test image
To adjust EQ:
1.
From normal-mode, press and hold the UP or DOWN button until the SKEW/RGB indicator turns on
(VIOLET). Release the UP or DOWN button.
2.
Press the UP or DOWN buttons repeatedly to adjust the EQ setting, either one step at a time or hold
for auto-repeat.
3.
To exit EQ-ADJUST mode, leave the buttons untouched for 10 seconds, or press the CFG button
once.
MultiView™ II AK600DP/AK1200DP Installation and User Guide
9
Installation
4.4.2
Skew Compensation Settings
If the AkuComp-II skew module is installed, it is possible to quickly adjust the RGB values when the MVIIAK600(1200)DP is operating in normal mode. The EQ/SKEW indicators 1-8 will change accordingly to show (in
“bargraph” form) 0 to 100% of the available SKEW adjustment range (0 to 65nSec).
For best results, use the Magenta EQ/Skew test pattern image if possible. A test pattern
image and video instructions is available at http://www.tvone.com.
If skew compensation is required, but the skew module is not installed, call for technical
assistance. Your product may need to have the skew-module added to it.
The following figure shows the test image you can use to make the SKEW adjustment.
Figure 6: Image Adjustment Utility Skew
To adjust skew:
1.
From normal mode, press and hold the SKEW/SEL button until the SKEW/RGB indicator turns on
RED. Release the SKEW button.
2.
Press the UP or DOWN button repeatedly to adjust the RED skew value.
3.
Press and release the SKEW/SEL button. The SKEW/RGB indicator will turn GREEN.
4.
Press the UP or DOWN button repeatedly to adjust the GREEN value.
5.
Press and release the SKEW/SEL button. The SKEW/RGB indicator will turn BLUE.
6.
Press the UP or DOWN button to adjust the BLUE value.
7.
Pressing the SKEW/SEL button again will return you to step-2, allowing adjustment of the RED skew
again.
8.
To exit SKEW-ADJUST mode, leave the buttons untouched for 10 seconds or press the CFG button.
MultiView™ II AK600DP/AK1200DP Installation and User Guide
10
Installation
4.5
Configuration Settings
There are a number of configurable operating parameters, and the factory-default settings should work for most
applications. However, some applications might require slight configuration changes.
This section describes how to configure the following settings:






Config-1 mode, LEDs 1-2:
Config-1 mode, LEDs 4-6:
Config-1 mode, LED 7:
Config-1 mode, LED 8:
Config-2 mode, LED 1-2:
Config-2 mode, LED 3:
Sync-mode settings
4th pair settings
Vsync polarity settings
Hsync polarity settings
Clamp-mode settings
4th pair termination settings
Nearly all settings are available from the front-panel buttons/LEDs. The enclosure does not need to be opened
unless an option module is being installed or removed, or settings specific to the option module need to be
changed.
4.5.1
Configuration Modes 1 & 2
For configuration settings, the receiver must be in Config Mode-1 or Config Mode-2 (CFG indicator is ON or
FLASHING). Once in a configuration mode, any changes are effective immediately and are saved in nonvolatile memory.
To enter Configuration Mode-1:

Press and hold the CFG button until the CFG indicator turns on.
o Once in this mode, the LED indicators 1-8 will display the current settings for the Config
Mode-1 settings.
To enter Configuration Mode-2:


Press and hold the CFG button until the CFG indicator turns on.
Press the SEL button exactly 5 times. The CFG indicator will start flashing.
o Once in this mode, the LED indicators 1-8 will display the current settings for the Config
Mode-2 settings.
To exit configuration-mode:


Leave the buttons untouched for 10 seconds. The CFG indicator will turn off (normal-mode).
Or, press the CFG button once. You will immediately leave the current Config mode.
To quickly reset all user-configurable options back to factory-default settings:
1.
Disconnect the DC power cable (or AC power).
2.
Press and hold the CFG button.
3.
Connect the DC power cable (or AC power). All LEDs blink 3 times, indicating all settings are now changed
back to factory-defaults.
4.
Release the CFG button.
MultiView™ II AK600DP/AK1200DP Installation and User Guide
11
Installation
4.5.2
Sync-mode Settings (LED1-2)
The receiver is factory-configured for auto-detecting the proper sync-mode (RepliSync-I normal/stretched). This
mode is generally compatible with all existing MultiView transmitter and receiver products that support
RepliSync (if they are also using their default settings).
However, some video sources may require a custom sync-mode setting (especially at 1080p and 1920x1200
video resolutions). For these cases, one of the other sync-modes can be selected. Note that any connected
MultiView device (transmitter or daisy-chained receiver) MIGHT also require a change to its sync-mode
settings. Otherwise, you may not get a proper video display output at one or more receivers.
Perform the following procedure while the receiver is in the normal operating state (CFG indicator is off):
1.
Press and hold the CFG button until the CFG indictor is ON. Release the CFG button.
a. LEDs 1-8 will show the current value for all Mode-1 configuration settings as bright (same as
ON), dim (same as OFF).
2.
Press and release the SKEW/SEL button once.
3.
LED indicators 1 and 2 should be illuminated (either ON or DIM); all others (indicators 3-8) should be off.
4.
Press the UP and DOWN buttons to step through the available sync-mode settings as shown below.
5.
To leave configuration-mode, leave the buttons untouched for 10 seconds or press the CFG button.
Table 3: Sync-Mode Settings
LED1
LED2
Front Panel View
Sync-mode Setting
dim
dim
The receiver will auto-detect the required RepliSync-I
mode (“normal” or “stretched”). This is the factorydefault setting.
dim
ON
Force RepliSync-II mode. This is compatible with MultiView
II “RepliSync-II” mode only (when connected to a
MultiView-II transmitter).
ON
dim
Force fixed-sync mode. NOTE: The source MultiView
transmitter must also be in fixed-sync mode. Note that H/V
polarity settings must also be selected at each receiver.
MultiView™ II AK600DP/AK1200DP Installation and User Guide
12
Installation
4.5.3
4th Pair Settings (LED4-6)
The receiver provides several options for using the 4th-pair signals (pairs 1-3 are generally used for video). The
factory-default setting (-S/A) supports summed L+R analog audio on the 4th-pair. Note that the connected
MultiView transmitter and any daisy-chained receivers must be configured with a matching 4th-pair operating
mode. Otherwise, the desired 4th-pair signal will not work as expected (but the video will not be affected).
Perform the following procedure while the receiver is in the normal operating state (CFG indicator is off):
1.
Press and hold the CFG button until the CFG indictor is ON. Release the CFG button.
a. LEDs 1-8 will show the current value for all Mode-1 configuration settings as bright/off.
2.
Press and release the SKEW/SEL button twice.
3.
LED indicators 4-6 should be illuminated (either DIM or ON); all others (indicators 1-3, 7 and 8) should be
off.
4.
Press the UP and DOWN buttons to step through the available 4th-pair settings as shown below.
5.
To leave configuration-mode, leave the buttons untouched for 10 seconds or press the CFG button.
Table 4: 4th-Pair Settings
4th-pair Operating Mode
If option-module is installed: 4th-pair operating mode
is defined by the presence of the option-module (SAP)
and this setting cannot be changed.
If the option-module is not installed: 4th-pair signals
are disabled. This effectively “mutes” anything being
sent on the 4th pair. This can be useful for diagnostic
purposes.
LED4
LED5
LED6
Front Panel View
dim
dim
dim
(THP: Need new photo.)
dim
dim
ON
Direct pass-through of 4th-pair wires (custom
applications).
dim
ON
dim
External analog (L+R summed) audio (“-A” mode).
This is the factory-default mode if no daughterboard
option is installed.
(Remember to also check 4th-pair termination setting)
dim
ON
ON
External S/PDIF digital audio. Output-impedance = 75ohms.
(Remember to also check 4th-pair termination setting)
ON
dim
dim
Simplex-serial (“-S” mode)
(Remember to also check 4th-pair termination setting)
MultiView™ II AK600DP/AK1200DP Installation and User Guide
13
Installation
4.5.4
Vsync Polarity Settings (LED7)
The receiver provides settings for Vsync polarity: (+) or (-).
The factory default setting is (+) Vsync polarity, or “ON” for configuration LED 7.
Perform the following procedure while the receiver is in the normal operating state (CFG indicator is off):
1.
Press and hold the CFG button until the CFG indictor is ON. Release the CFG button.
a. LEDs 1-8 will show the current value for all Mode-1 configuration settings as bright/off.
2.
Press and release the SKEW/SEL button three times.
3.
LED indicator 7 should be illuminated (either DIM or ON); all others (indicators 1-6 and 8) should be off.
4.
Press the UP and DOWN buttons to change Vsync polarity from Positive (ON) to Negative (DIM).
5.
To leave configuration-mode, leave the buttons untouched for 10 seconds or press the CFG button.
Note: This setting only has an effect if the sync-mode is set to “Fixed”.
4.5.5
Hsync Polarity Settings (LED8)
The receiver provides settings for Hsync polarity: (+) or (-).
The factory default setting is (+) Hsync polarity, or “ON” for configuration LED 8.
Perform the following procedure while the receiver is in the normal operating state (CFG indicator is off):
1.
Press and hold the CFG button until the CFG indictor is ON. Release the CFG button.
a. LEDs 1-8 will show the current value for all Mode-1 configuration settings as bright/off.
2.
Press and release the SKEW/SEL button four times.
3.
LED indicator 8 should be illuminated (either DIM or ON); all others (indicators 1-7) should be off.
4.
Press the UP and DOWN buttons to change Hsync polarity from Positive (ON) to Negative (DIM).
5.
To leave configuration-mode, leave the buttons untouched for 10 seconds or press the CFG button.
Note: This setting only has an effect if the sync-mode is set to “Fixed”.
MultiView™ II AK600DP/AK1200DP Installation and User Guide
14
Installation
4.5.6
Clamp-mode Settings (CFG2: LED1-2)
The receiver allows you to select the video clamp-mode.
Perform the following procedure while the receiver is in the normal operating state (CFG indicator is off):
1.
Press and hold the CFG button until the CFG indictor is ON. Release the CFG button.
a. LEDs 1-8 will show the current value for all Mode-1 configuration settings as bright/off.
2.
Press and release the SKEW/SEL button exactly five times.
a. The CFG indicator will start flashing.
b. LEDs 1-8 will show the current value for all Mode-2 configuration settings as bright/off.
3.
Press and release the SKEW/SEL button once.
4.
LED indicators 1 and 2 should be illuminated (either DIM or ON); all others (indicators 3-8) should be
off.
5.
Use the UP and DOWN button repeatedly to step through the available video-option settings as shown
below.
6.
To leave configuration-mode-2, leave the buttons untouched for 10 seconds or press the CFG button.
Table 5: Clamp-mode Settings
LED1
LED2
Front Panel View
Clamp-mode Settings
dim
dim
Auto-detect the required clamp-mode based on the video
signal format.
This is the factory-default mode.
dim
ON
Force clamp-mode Off.
If needed, this is the preferred setting for component/composite
video.
ON
dim
Force clamp-mode On.
If needed, this is the preferred setting for RGBHV (VGA) video.
Note: The default auto-detect clamp-mode setting will usually work for any RGBHV(VGA), component or
composite video signal being received from a MultiView transmitter. However, in some cases it may be
necessary to manually select either the OFF or ON setting: OFF is preferred for component & composite
signals; ON is preferred for RGBHV(VGA) signals.
MultiView™ II AK600DP/AK1200DP Installation and User Guide
15
Installation
4.5.7
4th Pair Termination Settings (CFG2: LED3)
The AK600 provides settings for 4th pair termination: ON or OFF. This setting has an effect only for “-S/A” and
S/PDIF operating modes.
Note: It is not possible to access the 4th-pair setting if an option board is installed – since this setting is ignored.

Set to ON for all single-receiver applications, and for the last receiver in a daisy-chained
configuration. This is the factory-default.

Set to OFF only for mid-span receivers in a daisy-chain configuration.
Perform the following procedure while the receiver is in the normal operating state (CFG indicator is off):
1.
Press and hold the CFG button until the CFG indictor is ON.
a. LEDs 1-8 will show the current value for all Mode-1 configuration settings as bright/on.
2.
Press and release the SKEW/SEL button five times.
a. The CFG indicator will start flashing.
b. LEDs 1-8 will show the current value for all Mode-2 configuration settings as bright/off.
3.
Press and release the SKEW/SEL button twice.
4.
LED indicator 3 should be illuminated (either DIM or ON); all others (indicators 1, 2 and 4-8) should be
off.
5.
Use the UP and DOWN buttons to turn 4th-pair termination ON (ON) or OFF (DIM).
6.
To leave configuration Mode-2, leave the buttons untouched for 10 seconds or press the CFG button.
MultiView™ II AK600DP/AK1200DP Installation and User Guide
16
Troubleshooting
Chapter 5
Troubleshooting
In most cases, nearly every issue with the MultiView™ video system can be resolved by checking the Category
cable termination and making sure that it’s pinned to the TIA/EIA 568B wiring specification. However, there
may be other problems that cause the system to not perform as it’s designed. The following table lists the most
common installation errors and their solutions.
Table 6: Troubleshooting Problems and Solutions
Problem
Solution
No video signal at
 Check that both units are powered and all necessary cables are firmly
the receiver
connected.
 Ensure receiver EQ and SKEW adjustments are set correctly. Change EQ
settings slowly to allow the display to re-acquire a valid signal and display the
image.
 During initial installation of a MVII receiver, it is very helpful to pre-set the EQ to
an approximately correct value. For example, if the UTP cable is known to be
approximately 300ft long:
o If you have a MVII-AK600DP, set the EQ to about ½ the maximum
setting on the EQ-range LEDs, which is approximately 300ft. This
would result in your EQ being set almost right for a 300ft cable and
you should be able to get a video image.
o If you have a MVII-AK1200DP receiver, set the range to about ¼ of
the maximum setting on the EQ-range LEDs, which again would
be approximately 300ft.
o Once you have a video image, it’s much easier to fine-tune the EQ
setting to get the best possible image on your display.
 Make sure the Category cable is terminated correctly per the TIA/EIA 568B
wiring specification.
 Is the display device powered on and functioning?
 Check to ensure display settings (resolution, refresh rate, etc) are compatible
with input signal.
Poor video quality at
 Ensure receiver EQ and SKEW adjustments are set correctly. Change EQ
receiver
settings slowly to allow the display to re-acquire a valid signal and display the
image.
 Check all cable connections.
 The video signal’s refresh rate may be set too high. Reset to a lower refresh
rate in your display-configuration menu (for example, under Windows on a PC).
 There may be a video-skew delay issue.
Poor audio quality
 The audio output at the receiver is line-level only. An amplifier or powered
speakers are required. Make sure amplifier or speaker power is ON.
 Check input source levels from the source device. Ensure the audio source
level does not exceed the audio-input ratings for the transmitter (ex: XRTx).
Clipping or distortion can result.
 Audio is summed left and right for “A” versions. If using a single channel, both
audio inputs must be connected at the transmitter end to obtain proper audio
gain through the link (1:1, input to output).
 If daisy chaining, audio termination must be removed in DP receivers
(AK600(1200)DP and XR2000DP). Only the last receiver requires termination.
This does not apply to SAP units. Refer to the appropriate receiver user
manual.
MultiView™ II AK600DP/AK1200DP Installation and User Guide
17
Troubleshooting
Problem
Serial
communication
doesn’t work
correctly
“Green shift” or
“green washout” on
multimedia signals
Notes on daisy
chaining
Solution
 Are the serial devices connected properly? Are the serial parameters correct
for source/destination devices?
 Are the serial cables terminated correctly? Is a null-modem cable required at
the TX or RX end?
 When using RS-232 capable receivers with video switches, distribution amps,
or multi-output transmitters, the serial data is sent transmit-only. Please take
this into account when trying to control displays or other devices. For
assistance, contact Magenta Technical Support.
 SA units have no configuration settings. They work from 50 to 9600 baud
automatically, and use 3 wire (TX, RX, GND) signals only.
 SAP units have a factory default baud rate of 9600 bps and use 3 wire (TX,
RX, GND) signals only. If necessary, use SAP-II serial commands to change
the baud rate to match your connected device.
The standard video/serial model is designed to function with DC coupled signals in
which the black level is referenced to 0 volts. Nearly all PC VGA cards function this
way.
Some media servers, however, provide AC coupled signals and can cause a green
color shift in the video. This is a result of the sync clamping on the red and blue
channels of the video/serial model.
For five-component (RGB/H&V) AC coupled video, the MultiView-II XRTx
transmitter has been designed with full DC restoration capability. This problem is
easily solved via a configuration setting in the transmitter. Please refer to the
appropriate transmitter user manual.
When utilizing a receiver’s RJ45 daisy chain port, the following rules apply:
•
If using L+R summed audio (-A), simplex serial (-S), or (-A) in SPDIF mode, a
maximum of 12 units may be daisy changed within the rated cable length of the
receiver.
•
When using SA units, a maximum of 4 units may be daisy chained within the
rated cable length of the receiver.
•
When using SAP units, a maximum of 12 units may be daisy chained within the
rated cable length of the receiver if using standard CAT5/6, or a maximum of 8
units may be daisy chained within the rated cable length of the receiver if using
low-skew cable.
•
When daisy chaining, the maximum cable distance is not increased beyond the
rated distance of the receiver used. For example, an MVII-AK600DP can only
daisy chain within 600ft of the transmitter. It is possible to daisy chain out of a
short range receiver into a longer range receiver to increase the range. For
example, over 600 ft an MVII-AK600DP can be daisy chained into an MVIIAK1200DP, which allows for daisy chaining to 1,200 ft.
MultiView™ II AK600DP/AK1200DP Installation and User Guide
18
Connector Pinouts
Chapter 6
Connector Pinouts
VGA Output Connector Pinout
The video output port connector is a standard HD-15 female connector (three-row, 15-pin).
Figure 7: HD-15 Female Connector
Table 7: HD-15 Pin Usage
Pin
RGBHV
RGBs
RGsB
1
Red +
Red +
Red +
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Green+
Blue+
—
Gnd
RedGreenBlue—
Gnd
Gnd
—
H Sync
V Sync
—
Green+
Blue+
—
Gnd
RedGreenBlue—
Gnd
Gnd
—
C Sync
—
—
Green+
Blue+
—
Gnd
RedGreenBlue—
—
—
—
—
—
—
Composite
S-Video
(Y/C)
C+
YUV
(YPrPb)
V+
C+
Y+
Y+
U+
C-
CY-
VYU-
MultiView™ II AK600DP/AK1200DP Installation and User Guide
19
Connector Pinouts
Auxiliary I/O (AUX-I/O) Connector Pinout
Pin #1
Pin #4
Figure 8: 4-pin Phoenix Connector Pinout
Table 8: Auxiliary I/O (4-pin Phoenix) Pin Usage
(S/A)
(S/A)
(S/A)
(SAP)
PIN#
Simplex
SPDIF
Audio
Audio
Serial
Audio
1
Left
Left
Tx
Signal +
(SIG1)
Channel Channel
2
Ground
Ground
ground
Signal (GND)
3
Right
Right
(SIG2)
Channel Channel
4
Shell
(GND)
MultiView™ II AK600DP/AK1200DP Installation and User Guide
20
Connector Pinouts
Serial port (IOIO) Connector Pinout
If the receiver is a “-SAP” version, then the serial interface will be provided on the “IOIO” connector. This is a
DB9-M type serial connector, configured to look like a standard 9-pin “DTE” serial port.
Therefore, in most applications a straight through serial cable or adapter-plug (DB9-Female-to-Male) is used to
connect an external serial device (for example, a display’s serial control port) to the receiver.
Figure 9: DB9-M Serial Port Connector
Table 9: Serial Port Pins
Pin#
Full Duplex
(RS 232)
3 wire (-SAP)
Simplex (-S/A)
1
DCD
2
RX
RX
3
TX
TX
TX
4
DTR
5
Ground
Ground
Ground
6
DSR
7
RTS
8
CTS
9
RI
MultiView™ II AK600DP/AK1200DP Installation and User Guide
21
Connector Pinouts
RJ45 (MultiView Link) Wiring Standard
Figure 10: T568B Category Cable Wiring Standard
Table 10: T568B wiring for RJ-45 plug
PIN #
COLOR
PAIR
1
White / Orange Stripe
2
2
Orange Solid
2
3
White / Green Stripe
3
4
Blue Solid
1
5
White / Blue Stripe
1
6
Green Solid
3
7
White / Brown Stripe
4
8
Brown Solid
Figure 11: Typical RJ-45 Plug
4
MultiView™ II AK600DP/AK1200DP Installation and User Guide
Pins on plug
face (socket is
reversed)
22
Connector Pinouts
DC Power Connector
tvONE provides ready-to-use power supplies for MultiView™ II products. However, if there is a reason a
substitute power supply must be used, then the following information is important for maintaining product
reliability and performance:
Magenta AC/DC Power supply output rating:
Regulated +5VDC @ 2.6Amps.
Power-input rating for MVII-AK600(1200)DP:
5VDC, 1.2Amps max.
The DC power input connector accepts an industry-standard coaxial-DC plug with the following specifications:






Coaxial power connector
OD = 5.5mm
ID = 2.5mm (accepted center-pin diameter)
Length = 11mm (overall length of insertable plug end)
Inner contact (pin-socket) = +5VDC
Outer contact (sleeve) = Ground
It is highly recommended that the inner contact (center-pin contact) of any mating DC plug utilize a “tuning-fork”
shaped design, rather than a plain barrel shape. The tuning-fork design greatly increases the reliability of the
power connection. The plain barrel style connector can cause intermittent operation, often resulting in
“mysterious” system problems that are difficult to identify.
Plain Barrel contact.
NOT PREFERRED
Figure 12: Plain Barrel Connector
Tuning-fork center contact.
PREFERRED
Figure 13: Tuning-fork Connector
The Magenta-provided power supply already comes with the correct output ratings and
DC-plug configuration
APPENDIX E: Skew Compensation Module
MultiView™ II AK600DP/AK1200DP Installation and User Guide
23
Skew Module Installation
Appendix A
Skew Module Installation
The AK600(1200)DP receivers have an optional skew compensation module that can be installed or removed.
To install the Skew Module:
1.
2.
3.
Disconnect external DC power and remove the top cover.
In the center area of the PCB there should be 3 jumpers
installed on J16, pins 1-2, 4-5 and 7-8.
Remove these jumpers (save for future use).
Figure 14: AK-600DP
receiver, cover removed.
J16
J17
Figure 15: Jumpers
across J16 installed
4.
5.
6.
7.
Figure 16: Jumpers
across J16 removed
Carefully orient the skew module with the Magenta logo
positioned as shown, and then firmly plug in the module so
that it mates completely with J16 and J17 on the mainboard. Incorrect orientation can cause damage to the
circuitry.
Double-check that all the J16 and J17 pins on the
mainboard are properly connected to the mating pins on
the skew module. It is easy to have a bent pin that causes
a shorted signal and possible circuitry damage.
Reassemble cover.
Connect power.
To remove the Skew Module, the procedure is reverse of
above. It is important to replace the 3 jumpers on J16 as
shown, or you will not have a video signal.
MultiView™ II AK600DP/AK1200DP Installation and User Guide
Figure 17: AK-600DP
receiver, skew module
installed
Logo
24
(SAP) Option Module Settings
Appendix B
(SAP) Option Module Settings
The SAP option module allows a bi-directional session to be established between a SAP-equipped transmitter
(XRTx-SAP), and a specific SAP-equipped receiver even in a multiple-receiver daisy chain installation.
The SAP transmitter devices (XRTx-SAP for example) do not have address DIP-switches. The factory-default
address of the transmitter is “0”.
The SAP receiver devices (AK600(1200)DP-SAP for example) have address DIP-switches.
Each SAP-equipped receiver must have a unique address set first, via DIP-switch settings or by a serial
command entered directly at the receiver.
Once this has been done, a special “set destination address” command is sent into the transmitter to specify
which receiver to open a session with.
If the XRTx-SAP is commanded to use destination address 0 (zero), serial data will be broadcast to all
receivers. This is the factory-default behavior.
To set the SAP receiver’s address switches, you will need to open the receiver enclosure and set the DIPswitches directly on the SAP module. The DIP-switch has 8 switches, one for each address bit position. Use
the SAP addressing chart provided on the next page to determine the proper switch addresses.
All receivers must have a unique address. It is recommended to write the address on each receiver once this
step has been completed. It is also recommended to keep a list of receiver addresses and locations to make it
easier to determine which receiver/display is desired to communicate with.
To set SAP address DIP-switches (at SAP-receiver units):
1.
Remove the top cover assembly of the receiver
2.
Remove the –SAP daughterboard.
3.
Locate the 8 position dipswitch on the internal daughterboard assembly and using the SAP-addressing
chart, set the receiver address as needed.
Figure 18: Internal Daughterboard Assembly with 8
Position Dipswitch
4.
Replace –SAP PCB with caution. Double check all the pins are aligned correctly.
5.
Replace cover assembly and install unit.
Note: It is also possible to set a SAP receiver’s address by a serial-command entered at the receiver itself. In
this case, simply ensure all DIP switches are set to address 0 (zero).
Please also refer to the SAP II Programmer’s Guide for additional information on SAP related settings and
operation.
MultiView™ II AK600DP/AK1200DP Installation and User Guide
25
Pollable Serial Mode Address Chart
Appendix C
ADDR
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
Pollable Serial Mode Address Chart
Switch Settings
1
ADDR
2
3
4
5
6
7
8
2
3
4
5
6
7
8
1
2
1
1
3
4
5
6
7
8
2
3
4
5
6
7
8
3
1
2
1
4
2
4
2
3
2
3
1
1
5
6
7
8
3
4
4
5
5
5
6
6
6
7
7
7
8
8
8
4
1
2
3
1
2
3
2
1
1
5
5
3
2
8
6
7
8
5
6
7
8
4
5
3
4
3
4
2
3
4
2
3
4
2
1
5
2
5
1
1
7
4
3
1
6
4
5
5
6
6
6
6
6
7
7
7
7
7
8
8
8
8
8
5
1
2
3
4
1
2
3
4
2
1
1
3
6
4
6
4
3
2
3
1
6
6
6
6
4
5
4
5
4
5
4
5
3
4
5
3
4
5
2
3
4
5
2
3
4
5
3
1
6
3
2
1
6
3
2
6
3
1
6
2
1
6
2
6
1
1
8
7
8
7
8
7
8
7
8
5
4
1
7
5
4
2
8
5
4
2
2
7
5
3
2
1
8
5
2
1
6
4
2
3
1
7
5
3
1
6
5
6
6
7
7
7
7
7
7
7
7
7
8
8
8
8
8
8
8
8
8
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
Switch Settings
ADDR
6
1
2
3
4
5
2
3
4
5
1
1
3
4
5
2
2
1
4
2
3
1
5
5
1
3
3
7
7
5
7
5
4
3
4
2
3
4
2
3
4
2
7
7
7
5
7
7
5
6
5
6
5
6
5
6
5
6
5
6
5
6
4
5
6
4
5
6
4
5
6
4
5
6
3
4
5
6
3
4
5
6
2
3
4
5
6
2
3
4
5
6
1
1
3
4
3
2
7
4
7
4
3
2
7
4
2
3
2
3
1
1
7
4
3
1
7
4
2
3
1
7
6
2
7
4
7
4
1
2
2
1
7
3
2
1
7
3
1
7
3
2
7
3
1
7
2
1
7
2
7
1
1
8
8
8
8
6
5
2
8
6
5
3
8
6
5
2
8
6
5
1
8
6
5
3
1
1
8
6
4
2
1
8
6
4
3
1
8
6
5
3
1
7
5
4
2
7
5
4
1
7
6
4
2
8
6
4
1
7
6
4
3
2
8
6
4
2
2
7
5
3
2
1
8
6
3
1
7
6
3
1
8
6
2
1
7
7
7
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
Switch Settings
ADDR
7
1
2
3
4
5
6
2
3
4
5
6
1
7
2
1
1
3
4
5
6
2
2
4
5
6
4
5
6
3
2
3
1
5
6
4
5
6
2
5
6
3
1
1
5
3
2
3
3
4
2
3
4
2
3
4
6
6
5
6
2
3
4
3
6
1
1
3
4
2
1
3
2
3
6
6
4
6
4
5
4
5
4
5
3
4
5
3
4
5
2
3
4
5
2
3
4
5
2
3
1
1
8
7
6
1
MultiView™ II AK600DP/AK1200DP Installation and User Guide
8
7
6
2
1
8
7
6
2
1
8
7
6
3
1
8
7
6
3
2
8
7
6
3
2
8
7
6
5
2
8
7
5
4
1
8
7
5
4
1
8
7
5
4
2
1
1
6
4
2
8
7
5
3
8
7
6
4
3
1
6
5
3
8
7
5
2
8
7
6
4
2
8
7
5
2
8
6
5
1
8
7
5
1
8
7
5
1
8
7
5
2
1
6
7
5
2
8
7
5
4
1
6
4
3
8
7
5
3
1
6
4
2
8
7
4
2
8
7
4
1
8
7
4
1
8
7
4
2
8
7
3
2
1
8
7
3
1
8
7
3
1
8
8
7
6
8
7
6
8
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
Switch Settings
6
1
2
3
4
5
2
3
4
5
1
7
6
7
6
7
6
7
6
7
6
7
6
7
6
7
6
7
6
7
6
7
6
7
6
7
6
7
6
7
5
6
7
5
6
7
5
6
7
5
6
7
5
6
7
5
6
7
5
6
7
5
6
7
4
5
6
7
4
5
6
7
4
5
6
7
4
5
6
7
3
4
5
6
7
3
4
5
6
7
2
3
4
5
6
7
2
3
4
5
6
7
1
3
4
4
2
4
4
2
3
2
3
1
1
4
4
2
3
1
1
1
5
3
4
3
4
2
3
4
2
3
4
2
8
8
5
2
8
5
1
1
8
5
3
1
8
5
4
3
1
8
5
4
2
8
5
3
2
8
5
4
2
8
5
4
1
8
5
3
2
8
5
3
1
8
5
2
3
1
8
6
2
1
7
8
5
8
5
1
2
3
4
1
2
3
1
3
2
1
8
4
3
2
8
4
2
3
2
3
1
1
8
4
3
1
8
4
2
3
8
4
2
1
8
8
4
8
4
1
2
3
1
2
1
8
3
2
1
8
8
3
2
8
3
1
8
2
1
8
2
8
1
1
8
8
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
26
Pollable Serial Mode Address Chart
SAP Addressing chart, cont’d:
ADDR
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
Switch Settings
ADDR
8
1
2
3
4
5
6
7
2
3
4
5
6
7
3
4
5
6
7
3
4
5
6
7
4
5
6
7
4
5
6
7
4
5
6
7
4
5
6
7
5
6
7
5
6
7
5
6
7
5
6
7
5
6
7
5
6
7
5
6
7
5
6
7
6
7
6
7
6
7
6
7
6
7
6
7
6
7
6
7
6
7
6
7
6
7
6
7
6
7
6
7
6
7
6
7
1
8
2
1
1
8
2
8
3
1
2
1
3
2
2
2
8
3
1
1
8
8
3
8
4
1
2
3
2
3
1
4
2
1
1
2
3
3
3
2
3
8
4
8
4
1
1
8
4
2
2
8
4
2
1
8
4
3
3
1
8
8
4
8
5
1
2
3
4
2
3
4
3
4
3
4
1
5
2
1
1
2
3
1
3
3
4
2
3
2
3
1
4
2
1
1
4
4
3
4
3
4
3
4
2
3
4
8
5
8
5
8
5
1
1
8
5
2
2
8
5
2
1
8
5
3
1
8
5
3
2
8
5
4
1
8
5
4
2
8
5
4
1
8
5
4
2
2
8
5
2
1
8
5
3
1
8
8
5
8
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
Switch Settings
ADDR
6
1
2
3
4
5
2
3
4
5
3
4
5
3
4
5
4
5
4
5
4
5
4
5
1
2
2
1
2
3
2
3
2
3
1
2
1
1
1
6
5
4
6
4
3
6
4
6
5
2
3
4
2
3
4
3
4
3
4
1
2
1
2
1
1
6
6
6
5
4
2
3
2
3
1
6
2
1
5
6
5
4
5
6
5
6
4
5
6
3
4
5
6
8
7
3
4
5
6
1
1
8
7
2
2
8
7
2
1
8
7
4
3
8
7
3
1
8
6
3
2
8
7
7
4
1
8
7
4
1
8
7
5
3
8
6
4
2
8
7
5
3
8
6
4
1
8
7
5
3
2
6
4
2
8
7
5
3
1
6
7
5
2
8
7
7
5
1
8
7
5
1
8
7
5
2
8
7
5
3
8
7
6
4
1
8
7
5
3
2
6
4
2
8
7
5
2
8
7
6
4
3
1
6
5
3
8
7
5
3
2
8
7
6
4
1
8
7
6
4
1
8
7
6
3
1
8
7
6
3
2
2
8
7
6
2
1
8
7
6
3
1
7
6
1
1
8
8
7
2
3
4
5
6
8
7
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
Switch Settings
ADDR
7
1
2
3
4
5
6
2
3
4
5
6
3
4
5
6
3
4
5
6
4
5
6
4
5
6
4
5
6
4
5
6
5
6
5
6
5
6
5
6
5
6
5
6
5
6
5
6
1
7
2
1
1
7
2
7
3
1
2
1
3
2
2
2
7
3
1
1
7
7
3
7
4
1
2
3
2
3
1
4
2
1
1
2
3
3
3
2
3
7
4
7
4
1
1
7
4
2
2
7
4
2
1
7
4
3
3
1
7
7
4
7
5
1
2
3
4
2
3
4
3
4
3
4
1
2
2
1
3
2
3
1
2
1
MultiView™ II AK600DP/AK1200DP Installation and User Guide
7
7
5
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
7
8
6
4
5
7
8
6
4
5
7
8
6
3
4
5
7
8
6
3
4
5
1
1
7
5
2
2
7
5
2
1
8
6
4
3
8
6
3
1
8
6
3
2
8
6
4
1
7
5
4
2
8
6
4
1
7
5
3
8
6
4
2
7
5
3
8
6
4
1
1
7
5
3
8
6
4
2
2
7
5
3
1
8
6
5
2
8
6
5
1
1
7
8
7
8
6
2
3
4
5
7
6
8
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
Switch Settings
1
6
7
8
6
7
8
6
7
8
6
7
8
6
7
8
6
7
8
6
7
8
6
7
8
6
7
8
6
7
8
6
7
8
6
7
8
6
7
8
6
7
8
6
7
8
6
7
8
5
6
7
8
5
6
7
8
5
6
7
8
5
6
7
8
5
6
7
8
5
6
7
8
5
6
7
8
5
6
7
8
4
5
6
7
8
4
5
6
7
8
4
5
6
7
8
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
2
3
4
5
6
7
8
2
3
4
5
6
7
8
2
3
4
5
2
3
4
5
3
4
5
3
4
5
4
5
4
5
4
5
4
5
1
2
1
1
2
3
1
2
1
3
2
2
3
1
1
2
3
4
1
2
3
2
3
1
4
2
1
1
5
5
4
3
2
5
4
3
3
1
5
4
2
1
5
3
4
2
2
5
3
4
1
1
5
2
3
4
5
1
2
3
4
2
3
4
3
4
3
4
1
2
1
1
2
3
1
2
1
4
3
2
2
4
3
1
1
4
2
3
4
1
2
3
2
3
1
2
1
1
3
2
3
1
2
1
2
1
1
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
27
Mounting Kits
Appendix D
Mounting Kits
The following table shows several kits available for mounting the MultiView™ II AK600(1200)DP receiver.
Table 11: AK600(1200)DP Mounting Kits
Mounting Kit #
2211054-01
Description
Rigid-mount bracket.
This mounts a single device to a surface
(wall/desk/etc.).
Comes with 4 self-tapping screws.
8310203-02
1U Rack-mount Plate for standard 19” rack.
Mounts 3 devices in a 1U space.
Comes with (6) device-mounting screws, (4) rack-mounting screws.
8310204-02
2U Rack-mount Plate for standard 19” rack.
Mounts 6 devices in a 2U space.
Comes with (12) device-mounting screws, (4) rack-mounting screws.
MultiView™ II AK600DP/AK1200DP Installation and User Guide
28
Mounting Kits
Note: When installing AK600(1200)DP receivers in an area susceptible to elevated operating temperatures
(near the maximum specified operating temperature), it is important to give careful consideration to maintaining
adequate air flow. Within a rack assembly, cable bundles and other equipment in the same rack can impede
proper cooling. In some rack-mount applications you may even need to leave a 1U gap (using a blank filler
plate) between receiver groups. For surface-mount applications, ensure the device will have adequate air
circulation and that air-vents on the enclosure are not blocked.
Figure 19: AK600(1200)DP with Rigid Mount Bracket
Figure 20: AD600(1200)DP with 1U Rack-mount Plate
Figure 21: AK600(1200)DP with 2U Rack-mount Plate
MultiView™ II AK600DP/AK1200DP Installation and User Guide
29
System Design Drawings
Appendix E
System Design Drawings
The following drawings are available from tvONE as an aid in system design and configuration. You may
download them from the tvONE website http://www.tvone.com. There is no charge for obtaining these
drawings.
Table 12: MultiView™ II AK600(1200)DP Drawings
Drawing #
2500133-01
2510004-01
Description
MultiView™ II AK600(1200)DP Sales Drawing (.dwg and .pdf format)
MultiView™ II AK600(1200)DP Autocad Symbols (.dwg and .pdf format)
MultiView™ II AK600DP/AK1200DP Installation and User Guide
30
Error! No text of specified style in document.
Index
About this manual, 1
Adjustments, 9
EQ setting, 9
Skew setting, 10
Installation, 6
Option Module Configuration, 6
prerequisites, 6
procedure, 7
Auxiliary I/O connector, 20
Mounting kits, 28
Configuration, 11
4th-pair mode settings, 13
4th-pair termination setting, 16
Clamp-mode settings, 15
Entering configuration mode, 11
factory defaults, 11
H-Sync settings, 14
Sync settings, 12
V-Sync settings, 14
Option module settings
SAP option module, 25
Connectors
auxiliary I/O, 20
DC power, 23
Link (RJ45), 22
serial, 21
VGA (HD15) input/output, 19
SAP addressing chart, 26
Pollable serial mode
addressing chart, 26
Precautions, iii
Product Overview, 2
Rear panel interfaces, 3
Serial port connector, 21
Skew Module Installation, 24
Default settings, 11
Specifications, 4
Category cables, 5
general, 4
Drawings, 30
System design drawings, 30
Front panel interfaces, 2
Troubleshooting, 17
MultiView™ II AK600DP/AK1200DP Installation and User Guide
31
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement