Below you will find brief information for TOM-L 30L, TOM-L 40L, TOM-L 50L, TOM-L 60L, TOM-L 75L, TOM-S 30S, TOM-S 40S, TOM-S 50S, TOM-S 60S, TOM-S 75S. This manual will guide you through installing and operating your Turbo Air open display merchandiser. Make sure to level the unit for proper water drainage and allow for proper air circulation. You’ll find the temperature control underneath the bottom shelf and the thermometer on the right side of the back panel. Keep the condenser coil clean and follow the maintenance guidelines for optimal performance.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Turbo Air Open Display Merchandiser TOM-L 30L, TOM-L 40L, TOM-L 50L, TOM-L 60L, TOM-L 75L Installation and Operation Manual | Manualzz

Turbo Air Speeds up the Pace of Innovation

Open Display Merchandiser

Installation and Operation Manual

Please read this manual completely before attempting to install or operate this equipment.

Horizontal Open Display Cases

TOM-30L*-**-*

TOM-40L*-**-*

TOM-50L*-**-*

TOM-60L*-**-*

TOM-75L*-**-*

TOM-30S*-**-*

TOM-40S*-**-*

TOM-50S*-**-*

TOM-60S*-**-*

TOM-75S*-**-*

TOM-W-30S*-**-*

TOM-W-40S*-**-*

TOM-W-50S*-**-*

TOM-W-60S*-**-*

TOM-W-75S*-**-* www.turboairinc.com

CONTENTS

INTRODUCTION

SPECIFICATIONS

INSTALLATION

Damage inspection

Location of display

Leveling of display

TURBO AIR RECOMMENDED OPERATING CONDITIONS

OPERATING INSTRUCTIONS

Power switch

Light switch

Temperature control

Thermometer

Placing the product

MAINTENANCE & CLEANING

Condenser coil

TROUBLESHOOTING

Merchandiser not functioning

Merchandiser is warm

Lights are not working

WIRING DIAGRAM

WARRANTY

PAGE

3

4

5

10

11 - 13

8

9

6

7

22

INTRODUCTION

This owner’s manual has important information. Please read the entire manual before installing your new Turbo Air Open Display Merchandiser.

For specific questions not answered on this manual, please call:

CUSTOMER SERVICE DEPARTMENT

TURBO AIR

4184 E. Conant St.

Long Beach, CA 90808

1-800-381-7770

Please write down the model and serial number of your merchandiser for future references:

MODEL NUMBER

SERIAL NUMBER

WARNING

Keep this manual in a safe place for your reference.

Failure to read this manual in its entirety can result in misuse of the equipment, which may cause personal injury or equipment failure.

WARNING!

Display Case should be on a minimum 20 Amps dedicated outlet and minimum 12 AWG wire for proper operation.

3

SPECIFICATIONS

Model

Dimension

(W x D x H) in.

TOM-30L*-**-* TOM-40L*-**-* TOM-50L*-**-* TOM-60L*-**-* TOM-75L*-**-*

28 x 34.6 x 45.8

39 x 34.6 x 45.8

50.8 x 34.6 x 45.8

63.2 x 34.6 x 45.8

75.6 x 34.6 x 45.8

Electricity

Full Load Amperes

Compressor

Refrigerant

Lighting

Defrost

Net Weight

7.5A

HK6A1C2U

7.2W X 2

257 lbs.

11A

120V/1PH/60HZ

11A

CAJ4476Y, NT6217Z

R-134A

10.8W X 2

317 lbs.

14.4W X 5

Timed off defrost

376 lbs.

15.5A

18.0W X 5

448 lbs.

15.5A

CAJ4492Y, NJ6220Z

21.6W X 5

507 lbs.

Model

Dimension

(W x D x H) in.

TOM-30S*-**-* TOM-40S*-**-* TOM-50S*-**-* TOM-60S*-**-* TOM-75S*-**-*

28 x 34.6 x 41.5

39 x 34.6 x 41.5

50.8 x 34.6 x 41.5

63.2 x 34.6 x 41.5

75.6 x 34.6 x 41.5

Electricity

Full Load Amperes

Compressor

Refrigerant

Lighting

Defrost

Net Weight

7.5A

HK6A1C2U

7.2W X 1

255 lbs.

11A

120V/1PH/60HZ

11A

CAJ4476Y, NT6217Z

R-134A

10.8W X 1

313 lbs.

14.4W X 1

Timed off defrost

370 lbs.

15.5A

18.0W X 1

440 lbs.

15.5A

CAJ4492Y, NJ6220Z

21.6W X 1

498 lbs.

Model

Dimension

(W x D x H) in.

TOM-W-30S*-**-* TOM-W-40S*-**-* TOM-W-50S*-**-* TOM-W-60S*-**-* TOM-W-75S*-**-*

26.9 x 34 x 56.5

38.9 x 34 x 56.5

50.9 x 34 x 56.5

62.7 x 34 x 56.5

75.2 x 34 x 56.5

Electricity

Full Load Amperes

7.5A

11A

120V/1PH/60HZ

11A 15.5A

15.5A

Compressor

Refrigerant

Lighting

Defrost

Net Weight

HK6A1C2U

6.0W X 3

354 lbs.

CAJ4476Y, NT6217Z

R-134A

9.6W X 3

425 lbs.

13.2W X 3

Timed off defrost

496 lbs.

CAJ4492Y, NJ6220Z

16.8W X 3

567 lbs.

20.4W X 3

638 lbs.

4

INSTALLATION INSTRUCTIONS

DAMAGE INSPECTION

Prior to installation, the customer must check for damages with the freight company before the unit is accepted.

1. If the crate is damaged, make sure to note the damage on the Bill of Lading

prior to signing the delivery off.

2. Concealed damage must be reported within 24 hours of receiving the unit. Bill

of Lading must be faxed to the Claims department. Pictures of both unit

and crating may be requested.

LOCATION OF OPEN DISPLAY MERCHANDISER

Open Display Merchandisers are designed to be in an area that is ambient 75 degrees Fahrenheit (dry bulb) or colder with 55 percent relative humidity. If the installed unit is in a warm ambient area, it may not be as effective. Position the

Merchandiser at the final location before removing the shipping skid. There are four bolts at the bottom of the merchandiser that secures the shipping skid.

Remove all four bolts to remove the skid.

Allow three inches of space from the wall to the back of the merchandiser. Condenser is located to the front. Do NOT block inlet.

LEVELING THE OPEN DISPLAY MERCHANDISER

Four leveling legs are provided to level your Merchandiser. Use a leveler to ensure the unit is evenly leveled on all four corners. If the unit is not leveled correctly, excess water buildup will not drain properly. If you do not wish to use the levelers, they can be turned inwards.

5

TURBO AIR RECOMMENDED OPERATING CONDITIONS

• Unit should not be placed

in direct sunlight.

• Unit should not be placed

near HVAC vents.

• Unit should not be placed

near fans.

• Unit should not be placed

near doorways.

• Confirm there is

enough clearance

for proper air

circulation.

• Level the cabinet on all four corners

of the base.

• Operating

environment not

to exceed 75ºF

(23ºC) and 55%

humidity.

• Do not load

product beyond

the edge of the

shelf

6

OPERATING INSTRUCTIONS

Level and set your merchandiser in place. Connect all necessary electrical connections. Your Open Display Merchandiser should now be ready for use.

POWER SWITCH:

Located at the bottom of front panel, colored in red.

LIGHT SWITCH:

Located at the bottom of front panel, colored in green.

TEMPERATURE CONTROL:

The temperature control is located underneath the bottom shelf and near the inner right-hand side of your merchandiser.

1. The default setting for the control is Normal.

2. The working temperature is from 37℉ to 40℉.

3. To lower the temperature, adjust the knob towards “COLD”.

To raise the temperature, adjust the knob towards “WARM”.

4. In case of icing caused by hikes in ambient temperature or humidity,

adjust the knob towards “WARM”.

THERMOMETER:

Thermometer showing temperature is located on the right side of the back panel under the fourth shelf.

NOTE:

• Do not place products into your merchandiser until the desired temperature is reached.

• Do not place hot products into the merchandiser.

PRODUCT PLACEMENT:

Overloading of product or placing products against the back wall may cause disruption in air flow, which may cause the unit to not cool properly.

7

MAINTENANCE & CLEANING

Always turn off your unit (both power and lights) when cleaning. Remove all products and allow your unit to reach room temperature. Do not allow electrical components to get wet.

CLEAN YOUR OPEN DISPLAY MERCHANDISER THOROUGHLY

BEFORE FIRST USAGE.

a. Do not clean with harsh detergents. Use mild soap.

b. Remove all products.

c. Remove shelves and bottom trays. d. Clean interior with warm water and mild detergent.

e. Wipe with damp cloth. Do not leave soap residue.

CLEANING THE CONDENSER COIL

Condenser coil is located at bottom behind panel.

1. Disconnect the electrical power to the unit.

2. Remove the front cover and base cover with screw driver.

3. Brush the dirt, lint, etc. from the finned condenser coil.

4. When finished, be sure to replace the front cover and base cover.

5. Reconnect the electrical power to the unit.

6. Condenser should be cleaned every 3 months or as needed.

8

TROUBLESHOOTING

For any problems with your unit, please refer to the following check list. If you are still experiencing problems or have questions, please call the Customer Service line at 1-800-381-7770.

Ⅰ. MERCHANDISER NOT FUNCTIONING a. Check to see that the breaker hasn’t tripped.

b. Check that enough power is BEING supplied to the unit.

c. Check that the power switch is on.

Ⅱ. MERCHANDISER IS WARM a. Check the condenser to see if it is clean. b. Check that the inner airflow is not being blocked by products.

Ⅲ. LIGHTS ARE NOT WORKING a. Check that light switch is on.

b. Check that the lights are placed in the lamp holders correctly.

9

WIRING DIAGRAM

10 timer

MANUFACTURING COMPANY

TWO YEAR WARRANTY

Turbo Air warrants to the original purchaser of every new Turbo Air refrigerated unit, the cabinet and all parts thereof, to be free from defects in material or workmanship, under normal use and service, for a period of two (2) year from the date of original installation or 27 months after shipment date from Turbo Air , whichever occurs first.

Any parts covered by this warranty that are examined and determined by Turbo Air to have been defective within two (2) year of original installation or twenty seven (27) months after shipment date from manufacturer, whichever occurs first, shall be repaired or replaced as stated below. Turbo Air shall be deemed to have fully complied with its obligation under the foregoing warranties by electing either one of the following procedures, at the sole discretion of Turbo Air.

1. Furnishing a replacement part, freight collect, in even exchange for the returned part, freight collect.

2. Receiving the defective part, freight collect; repairing it; and returning it, freight collect.

ADDITIONAL THREE YEAR COMPRESSOR WARRANTY

In addition to the (2) two year warranty stated above, Turbo Air warrants its hermetically and semi-hermetically sealed compressor to be free from defects in both material and workmanship under normal use and service for a period of three (3) additional years from the date of original installation but not to exceed five (5) years and three (3) months after shipment from manufacturer.

Compressors determined by Turbo Air have been defective within this extended time period will, at Turbo Airʼs option, be either repaired or replaced with a compressor or compressor parts of similar design and capacity.

The three (3) year extended compressor warranty applies only to hermetically and semi-hermetically sealed parts of the compressor and does not apply to any other parts or components, including, but not limited to, cabinet, paint finish, temperature control, refrigerant, metering device, driers, motor starting equipment, fan assembly any other electrical component, etcetera.

134A(404A) COMPRESSOR WARRANTY

The five year compressor warranty detailed above will be voided if the following procedure is not carefully adhered to:

1. This system contains R134A refrigerant and polyol ester lubricant. The Polyol ester lubricant has rapid moisture absorbing qualities. If long exposure to the ambient conditions occur, the lubricant must be removed and replaced with new. Listed below are the approved lubricants for the Tecumseh compressors.

1 ICI-Emkarate RL 184

2 Emery-2927-A

3 Mobile Artic 22A

Failure to comply with recommended lubricant specification will void the compressor warranty.

2. Dryer replacement is very important and must be changed when a system is opened for servicing. dryer must be used with XH-

9 desiccant.

3. Micron level vacuums must be achieved to insure low moisture levels in the system. 500 microns or lower must obtained.

What is NOT covered by this warranty

Turbo Airʼs sole obligation under this warranty is limited to either repair or replacement of parts, subject to the additional limitations below. This warranty neither assumes nor authorizes any person to assume obligations other than expressly covered by this warranty.

1. WARRANTY IS NOT TRANSFERABLE. This warranty is not assignable and applies only in favor of the original purchaser/user to whom delivered. ANY SUCH ASSIGNMENT OR TRANSFER SHALL VOID THE WARRANTIES HEREIN

MADE AND SHALL VOID ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF

MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

2. NO CONSEQUENTIAL DAMAGES. TURBO AIR IS NOT RESPONSIBLE FOR ECONOMIC LOSS; PROFIT LOSS OR

SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOSSES OR DAMAGES

ARISING FROM FOOD OR PRODUCT SPOILAGE CLAIMS WHETHER OR NOT ON ACCOUNT OF REFRIGERATION

FAILURE.

3. ALTERATION, NEGLECT, ABUSE, MISUSE, ACCIDENT, DAMAGE DURING TRANSIT OR INSTALLATION, FIRE,

FLOOD, ACTS OF GOD. TURBO AIR is not responsible for the repair or replacement of any parts that Turbo Air determines have been subjected after the date of manufacture to alteration, neglect, abuse, misuse, accident, damage during transit or installation, fire, flood, or an Act of God.

4. NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THERE ARE NO

OTHER WARRANTIES, EXPRESS, IMPLIED OR STATUTORY, EXCEPT THE TWO(2) YEAR WARRANTY AND THE

ADDITIONAL THREE (3) YEAR COMPRESSOR WARRANTY AS DESCRIBED ABOVE. THESE WARRANTIES ARE

EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, INCLUDING IMPLIED WARRANTY AND MERCHANTABILITY

OR FITNESS FOR A PARTICULAR PURPOSE. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE

DESCRIPTION ON THE FACE HEREOF.

5. TRANSPORTATION COSTS. Turbo Air will accept parts covered under this warranty freight collect, provided that shipment has received prior approval. Turbo Air is not responsible for any other transporation costs, but will ship freight collect parts either repaired or replaced under these warranties.

6. WARRANTY CLAIMS. All claims should include: model number of the cooler, the serial number of the cabinet, proof of purchase, date of installation, and all pertinent information supporting the existence of the alleged defect. Any action or breach of these warranty provisions must be commenced within two (2) year after that cause of action has accrued.

4184 E. Conant St.

Long Beach, CA 90808

TEL : 310-900-1000

FAX : 310-900-1077

TOLL FREE : 1-800-627-0032

(U.S.A. & Canada)

Website : www.turboairinc.com

Warranty Claims...

All claims for parts or labor must be made directly thorough Turbo Air.

All claims should include: model number of the unit, the serial number of the cabinet, proof of purchase, date of installation, and all pertinent information supporting the alleged defect.

In case of compressor replacement under warranty, either compressor or compressor tag must be returned to Turbo Air along with above listed information.

Failure to comply with warranty policies will result in voiding claims.

Two Year Parts & Labor Warranty...

Turbo Air warrants all new refrigerated components, the cabinet and all parts, to be free from defects in materials or workmanship, under normal and proper use and maintenance service as specified by Turbo Air and upon proper installation and start-up in accordance with the instruction packet supplied with each Turbo air unit. Turbo Airʼs obligation under this warranty is limited to a period of two (2) year from the date of original installation or 27 months after shipment date from Turbo Air, whichever occurs first.

Any part, covered under this warranty, that are by Turbo Air to have been defective within two (2) year of original installatio n or twenty seven

(27) months after shipment date from manufacturer, whichever occurs first, is limited to the repair or replacement, including labor charges, of defective parts or assemblies. The labor warranty shall include standard straight time labor charges only and reasonable travel time, as determined by Turbo Air.

Additional Three Year Compressor Warranty...

In addition to the two (2) year warranty stated adove, Turbo Air warrants its hermetically sealed compressor to be free from de fects in both material and workmanship under normal and proper use and maintenance service for a period of three (3) additional years from the date of original installation, but not to exceed five (5) years and three(3) months after shipment from the manufacturer.

Compressor determined by Turbo Air to have been defective within this extended period will, at Turbo Airʼs discretion, be either repaired or replaced with a compressor or compressor parts of similar design and capacity.

The three (3) year extended compressor warranty applies only to hermetically sealed parts of the compressor and does not apply to any other parts or components, including, but not limited to, cabinet, paint finish, temperature control, refrigerant, metering device, driers, motor starting equipment, fan assembly or and other electrical components, etcetera.

404A / 134a Compressor Warranty...

The five-year compressor warranty detailed above will be void if the following procedure is not carefully adhered to:

1. This system contains R404A or R134a refrigerant and polyol ester lubricant. The polyol ester lubricant has rapid moisture absorbing qualities.

2. Drier replacement is very important and must be changed when a system is opened for servicing. A620 copper drier or better is highly recommended.

3. Micron level vacuums must be achieved to insure low moisture levels in the system. 500 microns or lower must be obtained.

4. When compressor is grounded, suction drier and 620 drier or better must be replaced.

5. Compressor must be obtained through Turbo Air, unless otherwise specified in writing, through Turbo Airʼs warranty department.

404A / 134a Compressor Warranty...

Turbo Airʼs sole obligation under this warranty is limited to either repair or replacement of parts, subject to the additional limitations below. This warranty neither assumes nor authorizes any person to assume obligations other than those expressly covered by this warranty.

NO CONSEQUENTIAL DAMAGES. TURBO AIR IS NOT RESPONSIBLE FOR ECONOMIC LOSS; PROFIT LOSS; OR SPECIAL,

INDIRECT, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOSSES, OR DAMAGES ARISING FROM

FOOD OR PRODUCT SPOILAGE REGARDLESS OF WHETHER OR NOT THEY RESULT FROM REFRIGERATION FAILURE.

WARRANTY IS NOT TRANSFERABLE, This warranty is not assignable and applies only in favor of the original purchaser/user to whom delivered. ANY SUCH ASSIGNMENT OR TRANSFER SHALL VOID THE WARRANNTIES HEREIN AND SHALL VOID ALL

WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR LABOR COVERAGE FOR

COMPONENT FAILURE OR OTHER THE WARRANTY PACKET PROVIDED WITH THE UNIT.

ALTERATION, NEGLECT, ABUSE, MISUSE, ACCIDENT, DAMAGE DURING TRANSIT OR INSTALLATION, FIRE, FOOD, ACTS

OF GOD. Turbo Air is not responsible for the repair or replacement of any parts that Turbo Air determines have been subjected after the date of manufacture to alteration, neglect, abuse, misuse, accident, damage during transit or installation, fire, flood, or act of GOD.

IMPROPER ELECTRICAL CONNECTIONS. TURBO AIR IS NOT RESPONSIBLE FOR THE REPAIR OR REPLACEMENT OF

FAILED OR DAMAGED COMPONENTS RESULTING FROM ELECTRICAL POWER FAILURE, THE USE OF EXTENSION CORDS,

LOW VOLTAGE, OR VOLTAGE DROPS TO THE UNIT. NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A

PARTICULAR PURPOSE; THERE ARE NO OTHER WARRANTIES, EXPRESSED, IMPLIED OR STATUTORY, EXCEPT THE TWO

(2) YEAR PARTS & LABOR WARRANTY AND THE ADDITIONAL THREE (3) YEAR COMPRESSOR WARRANTY AS DESCRIBED

ABOVE. THESE WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, INCLUDING IMPLIED WARRANTY

AND MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THERE ARE NO WARRANTIES, WHICH EXTEND

BEYOND THE DESCRIPTION ON THE FACE HEREOF.

Outside U.S.and Canada; This warranty does not apply to, and Turbo Air is not responsible for, any warranty claims made on products sold or used outside the continent of the United States and Canada.

New Extended Warranty policy applies to all units sold by Turbo Air starting Dec.1, 2012

advertisement

Key Features

  • Open display design
  • Temperature control
  • Leveling legs
  • Condenser coil
  • Light switch
  • Power switch
  • Thermometer

Frequently Answers and Questions

How do I level the open display merchandiser?
Four leveling legs are provided to level the merchandiser. Use a leveler to ensure the unit is evenly leveled on all four corners. If the unit is not leveled correctly, excess water buildup will not drain properly. If you do not wish to use the levelers, they can be turned inwards.
What is the default temperature setting for the merchandiser?
The default setting for the control is Normal. The working temperature is from 37℉ to 40℉. To lower the temperature, adjust the knob towards “COLD”. To raise the temperature, adjust the knob towards “WARM”.
How do I clean the condenser coil?
Disconnect the electrical power to the unit. Remove the front cover and base cover with a screwdriver. Brush the dirt, lint, etc. from the finned condenser coil. When finished, be sure to replace the front cover and base cover. Reconnect the electrical power to the unit. The condenser should be cleaned every 3 months or as needed.