AT-CV10x Series Media Converter Line Cards

AT-CV10x Series Media Converter Line Cards
*613-000296 Rev D*
Port Descriptions
The fiber optic port on the AT-CV10x Series line card is IEEE 802.3ah-compliant. The
connectors and operating distance vary depending upon the model:
613-000296 Rev. D
ˆ
ˆ
ˆ
AT-CV10x Series Converteon Line Cards
Installation Guide
ˆ
The AT-CV10x Series (AT-CV101, AT-CV102, and AT-CV102/x Series) line cards feature
a 10Base-TX twisted pair port and a 100Base-FX fiber optic port. You can install these
line cards in any Converteon Series chassis. The line card features one fiber optic port
and one copper twisted pair port. Both ports feature half- or full-duplex mode operation.
The line cards are hot-swappable into and out of a Converteon chassis.
AT-CV101: multi-mode fiber ST connector and a maximum operating distance of 2km
(1.24 miles)
AT-CV102: multi-mode fiber SC connector and a maximum operating distance of 2km
(1.24 miles)
AT-CV102/1: single mode fiber SC connector with a maximum operating distance of
15km (9.32 miles)
AT-CV102/2: single mode fiber SC connector with a maximum operating distance of
40km (24.85 miles)
For details on the features and functions of a Converteon chassis, refer to the relevant
documents on our web site, www.alliedtelesis.com.
ML
1 2 3 4
3K
1 2 3 4
To install an AT-CV10x Series line card, perform the following procedure:
3K
SW2
1 2 3 4
1 2 3 4
Remove the AT-CV10x Series line card from its shipping package and store the
package in a safe place. You must use the original package if you need to return the
unit to Allied Telesis.
2.
Configure the line card’s DIP switches as required. Refer to “DIP Switch Settings” for
more information.
3.
Select any line card slot in the chassis where you want to install the AT-CV10x
Series line card, and remove the blank slot cover if one is installed.
4.
Align the back edge of the line card with the to and bottom alignment guides located
inside the slot.
5.
Slide the line card into the slot until the front of the card is flush with the front of the
chassis.
3K
SW1
3K
AT-C
V
10 2
LK AT
T
X
M
M
R
X
Twisted Pair Port LEDs
10/100-TX Twisted Pair Port
LK
AT
T
X
SML
ML
LK
AT
RDY
Line Card Status LEDs
The line card has passed diagnostics.
Off
The line card has not passed diagnostics.
Green
The Smart MissingLink mode is enabled.
Off
The Smart MissingLink mode is disabled.
Green
The MissingLink mode is enabled.
Off
The MissingLink mode is disabled.
State
Description
Green
A link has been established on the port.
Blinking
Green
While in Smart MissingLink mode, a valid connection is established
on the port while a link on the other port is lost.
Off
No link has been established on the port.
Blinking
Green
TX/RX activity has been detected on the port.
Off
There is no TX/RX activity on the port.
Twisted Pair Port LEDs
LED
1.
SW2
Green
The twisted pair port has three LEDs, as described in the following table. For more
information about Smart MissingLink, refer to the relevant management software user’s
guide.
Note
You can install a Converteon line card in any Converteon chassis line card slot.
SW1
LK
AT
Caution: Be sure to observe all standard electrostatic (ESD) precautions, such as
wearing an antistatic wrist strap, to avoid damaging the device. A line card can be
damaged by static electricity
SW1 DIP Switch Set
Description
The fiber optic port has two LEDs, as described in the following table. For more
information about Smart MissingLink, refer to the relevant management software user’s
guide.
LED
Warning: Remove all metal jewelry, such as rings and watches, before installing
or removing a line card from a powered-on chassis.
An AT-CV10x Series line card has the components shown below. The AT-CV102 line card
is shown as an example.
State
Fiber Optic Port LEDs
Note
Before you install an AT-CV10x Series line card, refer to the appropriate Converteon
chassis installation guide for electrical safety and emissions information.
AT-CV10x Series Line Card Components
Fiber Optic Port
LED
LEDs
If any item is missing or damaged, contact your Allied Telesis sales representative for
assistance.
Fiber Optic Port LEDs
The line card has three status LEDs as described in the following table. For more
information about Smart MissingLink and MissingLink, refer to the relevant management
software user’s guide.
SML
Installing an AT-CV10x Series Line Card
One AT-CV10x Series line card
This installation guide
SW2 DIP Switch Set
Status LEDs
The 10/100Base-TX compliant twisted pair port has an RJ-45 connector and a maximum
operating distance of 100 meters (328 feet). Category 5 (5E), 100 Ohm shielded or
unshielded twisted pair cabling is required. The pinouts for this port are shown in
“Twisted Pair Port Pinouts.”
Two sets of DIP switches allow you to set the operating mode and MDI/MDI-X features, as
described in “DIP Switch Settings.”
Ensure that the following items are included in your package:
ON
LED Descriptions
RDY
DIP Switches
Verifying Package Contents
ON
Repeat this procedure to install additional AT-CV10x Series line cards.
An AT-CV10x Series line card as three status LEDs, two LEDS for the fiber optic port, and
three LEDs for the twisted pair port, as described in “LED Descriptions.”
Related Documents
ˆ
7.
Twisted Pair Port
Overview
ˆ
Note
Always tighten the captive screw to secure the line card to the chassis.
Fiber Optic Port
FD
State
Description
Green
A link has been established on the port.
Blinking
Green
While in Smart MissingLink mode, a valid connection is established
on the port while a link on the other port is lost.
Off
No link has been established on the port.
Blinking
Green
TX/RX activity has been detected on the port.
Off
There is no TX/RX activity on the port.
Green
(AT-CV102 only) The port is operating in full-duplex mode.
Off
The port is operating in half-duplex mode.
Note
Avoid touching the line card components.
555
6.
1
Secure the AT-CV10x Series line card to the chassis by using a Phillips screwdriver
to tighten the captive screw on the faceplate.
2
3
DIP Switch Settings
Specifications
SW 1 DIP Switches
Physical, Environmental, and Electrical Ratings
The DIP switches in the SW 1 DIP switch set described in the following table allow you to
set the operating mode of the line card. For information about the operating modes as
well as Smart MissingLink and MissingLink, refer to the relevant management software
user’s guide.
Dimensions (H x W x L)
(2.2 cm x 7.3 cm x 13.0 cm)
.855 in. x 2.89 in. x 5.1 in.
Weight
0.27kg (0.60 lbs.)
Operating Temperature
0° C to 40° C (32° F to 104° F)
Storage Temperature
-25° C to 70° C (-13° F to 158° F)
Operating Mode
DIP 1
Link Test (default)
OFF
DIP 2
OFF
DIP 3
OFF
DIP 4
X
Smart MissingLink (SML)
OFF
ON
ON
X
MissingLink (ML)
OFF
OFF
ON
X
Manufacturing Default Settings
OFF
OFF
OFF
OFF
Operating Relative Humidity
5% to 90% (non-condensing)
Storage Relative Humidity
5% to 95% (non-condensing)
Operating Altitude Range
Up to 3,048 m (10,000 ft.)
Predicted MTBF (Telcordia SR332)
AT-CV101
1,020,000 hours
AT-CV102
890,000 hours
AT-CV102/1 1,020,000 hours
“X” means that the DIP switch position can be ON or OFF.
AT-CV102
SW 2 DIP Switches
The DIP switches in the SW 2 DIP switch set described in the following table allow you to
configure the MDI/MDI-X feature on the twisted pair port..
Operating Mode
DIP 1
DIP 2
DIP 3
DIP 4
Power Consumption
1,020,000 hours
5.7 Watts
Optical Output Power (dBm)
Line Card
Minimum
Maximum
Wavelength
Connector
Auto MDI-X Enabled (default)
X
OFF
X
X
AT-CV101
-20 dBm
-14 dBm
1310 nm
Dual ST
Auto MDI-X Disabled
X
ON
X
X
AT-CV102
-20 dBm
-14 dBm
1310 nm
Dual SC
Manufacturing Default Settings
OFF
OFF
OFF
OFF
AT-CV102/1
-15 dBm
-5 dBm
1310 nm
Dual SC
AT-CV102/2
-15 dBm
0 dBm
1310 nm
Dual SC
“X” means that the DIP switch position can be ON or OFF.
Twisted Pair Port Pinouts
Receiver Power Sensitivity (dBm)
The pinouts for the RJ-45 twisted pair port are shown in the following illustration.
8
1
8
Line Card
1
The following table lists the RJ-45 pin signals when a twisted pair port is operating in the
MDI or MDI-X mode.
MDI Mode
Pin
Pin
TX+
1
RX+
2
TX-
2
RX-
3
RX+
3
TX+
6
RX-
6
TX-
AT-CV101
-31 dBm
-11 dBm
AT-CV102
-31 dBm
-11 dBm
AT-CV102/1
-34 dBm
-3 dBm
AT-CV102/2
-34 dBm
-3 dBm
Electrical Safety and Emissions Statements
U.S. Federal Communications Commission
Signal
1
Maximum
This product meets the following standards when installed in compliant host equipment.
MDI-X Mode
Signal
Minimum
Radiated Energy
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to
Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to
operate this equipment.
Industry Canada
Warranty Information
The AT-CV10x Series (AT-CV101, AT-CV102, and AT-CV102/x Series) line cards have a
limited warranty of five years. Go to www.alliedtelesis.com/warranty for the specific terms
and conditions of the warranty and for warranty registration.
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment
Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du
Canada.
Emissions
FCC Class A, EN55022 Class A, VCCI Class A, C-TICK, CE
Warning: In a domestic environment this product may cause radio interference in which
case the user may be required to take adequate measures.
4
Immunity
EN55024
Electrical Safety
UL60950 (cULus), EN60950 (TUV), CSA22.2 No. 950
Copyright © 2007 Allied Telesis, Inc. All rights reserved.
No part of this publication may be reproduced without prior written permission from Allied
Telesis, Inc.
5
6
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement