Mytee 7000S Flood Hog User manual
Below you will find brief information for Flood Hog 7000S Flood Hog. The 7000S Flood Hog is a heavy-duty wet/dry vacuum that can be used for a variety of applications, including flood cleanup, general cleaning and even boosting the airflow of a larger extractor. The 7000S Flood Hog features a 35 GPM pump that allows it to quickly remove large amounts of water. The 7000S Flood Hog also has a dual vacuum system that allows you to extract from two different locations at the same time. The machine also features an auto pump-out system that automatically pumps out dirty water from the recovery tank.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
7000S
Flood Hog
™
6
Please read before use.
F
Register your product at: http://www.mytee.com/ support/register
E
D
5 4 3
REV.
OD
2
REVISIONS
DESCRIPTION
ORIGINAL DRAFT
DATE
1
APPROVED
JFL
F
E
D
C
B
A
Set up p. 2
Parts & Pricing p. 7
Wiring diagram p. 9
General information p.10
Notes p.12
8 7 6
13655 Stowe Dr., Poway, CA 92064
1
5 4
Model #
Serial #
Form # ADM-7000S
5-15
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN INCHES
TOLERANCES:
ANGULAR: MACH .5
ONE PLACE DECIMAL .03
TWO PLACE DECIMAL .05
THREE PLACE DECIMAL .003
MATERIAL
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
MYTEE PRODUCTS, INC. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
MYTEE PRODUCTS, INC. IS
PROHIBITED.
FINISH
DRAWN
CHECKED
COMMENTS:
NAME
V. LaBarbera
3 2
DATE
mytee
PRODUCTS, INC.
858-679-1191
TITLE:
Flood Hog (2014)
A
SIZE DWG. NO.
C
SCALE: 1:8
7000S
DO NOT
SCALE DRAWING
1
REV
OD
SHEET 1 OF 1
B
C
7000S FLOOD HOG™
7
7000S FRONT
6 5
8 7
6
4
F
3
REV.
OD
2
REVISIONS
DESCRIPTION
ORIGINAL DRAFT
DATE
1
APPROVED
JFL
F
E
E
6 5
7000S BACK
4
7
12
E
F
8
1
D
C
B
A
2
1. Recovery Tank Lid
2. Operating Controls
3. Handles
4. EZ Open Service Latches
5. Drain Valve
6. Vacuum Hose Hook-up
6 5
3
REV.
OD
2
REVISIONS
DESCRIPTION
ORIGINAL DRAFT
DATE
1
APPROVED
JFL
F
D 5
C
4
3
8
D
C
B
4
B
A
UNLESS OTHERWISE SPECIFIED: NAME
DRAWN
V. LaBarbera
CHECKED
COMMENTS:
DATE
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
MYTEE PRODUCTS, INC. ANY
REPRODUCTION IN PART OR AS A WHOLE
MATERIAL
FINISH
WITHOUT THE WRITTEN PERMISSION OF
MYTEE PRODUCTS, INC. IS
PROHIBITED.
3 2 mytee
TITLE:
Flood Hog (2014)
A
9
SIZE DWG. NO.
C
SCALE: 1:8
7000S
REV
OD
SHEET 1 OF 1
7. 2” Female Cuff-Lynx™ starter
8. 2” Male Cuff-Lynx™ plug
9. 25’ Power Cord
10. 10” Stair Climbing Wheels
8 7 6 5
12. Auto Pump-out Hose Connection
10
4
11
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN INCHES
TOLERANCES:
ANGULAR: MACH .5
ONE PLACE DECIMAL .03
TWO PLACE DECIMAL .05
THREE PLACE DECIMAL .003
MATERIAL
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
MYTEE PRODUCTS, INC. ANY
REPRODUCTION IN PART OR AS A WHOLE
MYTEE PRODUCTS, INC. IS
PROHIBITED.
FINISH
DRAWN
CHECKED
COMMENTS:
NAME
V. LaBarbera
3 2
DATE mytee
PRODUCTS, INC.
858-679-1191
TITLE:
Flood Hog (2014) A
SIZE
C
SCALE: 1:8
REV
OD
SHEET 1 OF 1
1
B
D
C
E
7000S ACCESSORIES WAND INTERCHANGEABLE HEADS
H908 - 2 Piece Aluminum
Wand Tube
P570 - Scalloped Vacuum Head
B
A
E
D
C
F
H294 - 1.5” x 25’ Vacuum
Hose (x2)
G200 - Squeegee Vacuum Head
8 7
H121 - 2”
Cuff Lynx™ Plug
H226 - Drain Elbow
6 5
H141 - 2” x 1.5”
Cuff Lynx™ Reducer
FILTERS
G008 - Pack Of Filters
4 3 2 1
F
Select either vacuum head and attach to wand. Insert head and tighten collar.
E
D
2
C
B
2
DRAWN
CHECKED
NAME
J.Cash
DATE
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
MYTEE PRODUCTS, INC. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
MYTEE PRODUCTS, INC. IS PROHIBITED.
TITLE: mytee
PRODUCTS, INC.
A spout, drain, 45 degree
SCALE: 1:2
1
REV
SHEET 1 OF 1
8 7 6 5 4 3
C
B
A
F
E
D
8
8 7
7
6 5 4 3
REV.
OD
2
REVISIONS
DESCRIPTION
ORIGINAL DRAFT
DATE
1
APPROVED
JFL
F
7000S FRONT VACUUM/DEBRIS FILTER HOSE
HOOK UP
7000S FLOOD HOG™
7000S BACK VACUUM HOSE/AUTO PUMP-OUT
HOOK UP
E
Attach the hose with the 1.5” Cuff-Lynx™ reducer to the machine.
Attach other end of same hose to wand tube.
7000S DUAL CORDS
Top cord: Powers Vac 1 & Pump.
Bottom cord: Powers Vac 2.
Attach the second hose bearing cam lock to the Auto Pump-out fitting. Secure the hose to the fitting using the cam lock. Push the hose cuff onto the fitting, making sure the silver ears and rings are extended forward. Pull the ears down using the rings until connection is tight. Place the end of the hose in a location where dirty water can drain.
7000S SWITCHES
Yellow tag indicates primary cord.
VACUUM 1 V
ACUUM 2 PUMP
Dual circuit indicator light.
6
Plug each power cord into a separate, 20A grounded wall outlet.
Outlets must be on two separate breakers. When the amber light on the switch plate illuminates, the machine is on separate circuits (not necessarily 20A circuits). You can identify the primary cord by the yellow tag.
Three switches are located on the lower left side of the machine.
To use either vacuum, turn on the Vacuum switch 1 or 2. To use the pump, turn on the Pump switch.
3
5 4
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN INCHES
TOLERANCES:
ANGULAR: MACH .5
ONE PLACE DECIMAL .03
TWO PLACE DECIMAL .05
THREE PLACE DECIMAL .003
MATERIAL
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
MYTEE PRODUCTS, INC. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
MYTEE PRODUCTS, INC. IS
PROHIBITED.
FINISH
DRAWN
CHECKED
COMMENTS:
NAME
V. LaBarbera
3 2
DATE
mytee
PRODUCTS, INC.
858-679-1191
TITLE:
Flood Hog (2014)
A
SIZE DWG. NO.
C
SCALE: 1:8
7000S
1
REV
OD
SHEET 1 OF 1
B
D
C
8 7 6 5
4
3
REV.
OD
2
REVISIONS
DESCRIPTION
ORIGINAL DRAFT
1
DATE APPROVED
JFL
F
F
B
A
C
D
F
E
8
E
7000S FLOOD HOG™
7 6 5 4
7000S WATER LEVEL CONTROL SWITCHES
Vacuum stack filter
D
Vacuum water level control switch
3
REV.
OD
2 1
REVISIONS
DESCRIPTION DATE APPROVED
ORIGINAL DRAFT JFL
7000S DRAIN VALVE AND SPOUT
E
Pump-out water level control switch
D
8
C
C
B
As the water level reaches the pump-out water level control
switch, the pump is activated. Once the water level reaches the
vacuum water level control switch, the vaccum shuts off preventing the water from going into the vacuum stack, damaging the
5 vacuum motors. At the top of the vaccum stack, there is a filter.
Clean it weekly.
F
7
B
6 5 4
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
MYTEE PRODUCTS, INC. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
MYTEE PRODUCTS, INC. IS
PROHIBITED.
3
When not using the Auto Pump-out, empty the tank by using the
UNLESS OTHERWISE SPECIFIED: drain valve on the front of the machine with the included drain
ANGULAR: MACH .5 elbow (part # H226).
MATERIAL
DRAWN
CHECKED
NAME
V. LaBarbera
DATE mytee
PRODUCTS, INC.
858-679-1191
TITLE:
REV.
A
DESCRIPTION
ORIGINAL DRAFT
DATE
1
FINISH
2
SIZE
C
SCALE: 1:8
1
REV
OD
SHEET 1 OF 1
REAR PLUGS
E
Cap top plug to use as a booster and pass-through
APPROVED
JFL
E
F
Cap bottom plug to use as booster with pump-out
B
D
A
Cap both plugs to use as a flood extractor
C
8 7 6 5
D
C
B
Two vacuum plugs are located in the back. The top and bottom rear plugs, depending on how they are capped, allow the Flood Hog™ to
UNLESS OTHERWISE SPECIFIED: NAME DATE be used as a stand-alone extractor, a flow-through booster connected to another machine, or an in-line pump-out unit. They also seal the
Flood Hog™ vacuum tank.
ANGULAR: MACH .5
ONE PLACE DECIMAL .03
TWO PLACE DECIMAL .05
THREE PLACE DECIMAL .003
DRAWN
CHECKED
COMMENTS:
PROPRIETARY AND CONFIDENTIAL
DIMENSIONS ARE IN INCHES
TOLERANCES:
MATERIAL mytee
PRODUCTS, INC.
858-679-1191
TITLE:
Flood Hog (2014)
A
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
MYTEE PRODUCTS, INC. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
MYTEE PRODUCTS, INC. IS
PROHIBITED.
FINISH
SIZE
C
SCALE: 1:8
REV
OD
SHEET 1 OF 1
8 7 6 5 4 3 2 1
4
4
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN INCHES
TOLERANCES:
ANGULAR: MACH .5
ONE PLACE DECIMAL .03
TWO PLACE DECIMAL .05
THREE PLACE DECIMAL .003
MATERIAL
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
MYTEE PRODUCTS, INC. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
MYTEE PRODUCTS, INC. IS
PROHIBITED.
FINISH
DRAWN
CHECKED
COMMENTS:
NAME
V. LaBarbera
3 2
DATE
mytee
PRODUCTS, INC.
858-679-1191
TITLE:
Flood Hog (2014)
A
SIZE
C
DWG. NO.
7000S
SCALE: 1:8
DO NOT
SCALE DRAWING
1
REV
OD
SHEET 1 OF 1
E
D
C
B
F
E
B
D
C
A
8
8 7 6
F
5
8
7000S DEBRIS FILTER
E
D
4
7 6 5
4
3 2
REVISIONS
REV.
DESCRIPTION
OD ORIGINAL DRAFT
7000S FLOOD HOG™
DATE
1
APPROVED
JFL
F
7000S LATCHES AND LIFT HANDLE
LATCHES:
Detach: Flip-up latch.
Twist counter clockwise for release.
Attach: Place latch.
Twist clockwise
Press latch to secure.
E
D
3
REV.
OD
2
REVISIONS
DESCRIPTION
ORIGINAL DRAFT
DATE
1
APPROVED
JFL
F
C
The filter protects the vacuum motor from damaging debris. Keep it clean by removing the vacuum hose and opening the recovery tank lid via the latch on the front of the machine. Remove stainless steel basket and gently rinse with water. Dry with a soft cloth.
Replace basket, lid and hose.
B
LIFT HANDLE: Use lift handle to prevent damage to unit.
7000S FLOOD HOG™ IN USE
7
DRAIN
6
A
5
8
4
7
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN INCHES
TOLERANCES:
DRAWN
CHECKED
COMMENTS:
ANGULAR: MACH .5
ONE PLACE DECIMAL .03
TWO PLACE DECIMAL .05
THREE PLACE DECIMAL .003
MATERIAL
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
MYTEE PRODUCTS, INC. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
MYTEE PRODUCTS, INC. IS
PROHIBITED.
FINISH
NAME
V. LaBarbera
3 2
6
DATE
5
mytee
PRODUCTS, INC.
858-679-1191
TITLE:
Flood Hog (2014)
A
SIZE DWG. NO.
C
SCALE: 1:12
7000S
1
REV
OD
SHEET 1 OF 1
4
FLOODED AREA
C
B
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN INCHES
TOLERANCES:
ANGULAR: MACH .5
ONE PLACE DECIMAL .03
TWO PLACE DECIMAL .05
THREE PLACE DECIMAL .003
MATERIAL
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
MYTEE PRODUCTS, INC. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
MYTEE PRODUCTS, INC. IS
PROHIBITED.
FINISH
DRAWN
CHECKED
COMMENTS:
NAME
V. LaBarbera
3 2
DATE
mytee
PRODUCTS, INC.
858-679-1191
TITLE:
Flood Hog (2014)
A
SIZE DWG. NO.
C
SCALE: 1:8
7000S
DO NOT
SCALE DRAWING
1
REV
OD
SHEET 1 OF 1
C
B
Flood Hog™ pumps up to 35 GPM.
5
E
D
7000S FLOOD HOG™
3. USING THE FLOOD HOG™ AS A BOOSTER WITH AUTO PUMP-OUT
Solution flow
Dirty water recovery
Pump-out system
Base extractor airflow
* Wand & extractor not included with Flood Hog™
#2
B
A
C
#1
Drain
The optional pump-out can be used in conjunction with a second, larger extractor (#1), which will be used as a clean water
source. A. Connect a vacuum and solution hose to the larger extractor (#1) and the Flood Hog’s™ (#2) rear top plug. Keep the bottom rear vacuum plug capped. B. Attach the wand’s vacuum hose to the Flood Hog’s™ front vacuum port and attach the solution hose to the larger extractor’s QD. C. Connect the Flood Hog’s™ pump-out hose to the Flood Hog™ via the cam-lock fitting on the rear of the machine.
Turn on the pump-out switch. Dirty water will be automatically pumped out of the Flood Hog™.
4. USING THE FLOOD HOG™ AS A BOOSTER AND PASS-THROUGH EXTRACTOR
Solution flow
Dirty water recovery
* Wand & extractor not included with Flood Hog™
#2
A
B
#1
The Flood Hog™ (#2) can be used as a pass-through extractor and to boost the airflow of a second, larger extractor (#1) by
increasing its CFM by 113. A. To do this, use the larger extractor (#1) as a fresh water source and recovery tank, connect a vacuum hose to the larger extractor and the Flood Hog’s™ (#2) rear bottom plug. Keep the top rear plug capped. B. To use a wand, attach the wand’s vacuum hose to the front of the Flood Hog™ and attach the solution hose to larger extractor and to the wand. Clean water will travel from the larger extractor to the wand to clean the surface, and dirty water will be drawn through the Flood Hog™ into the main extractor’s recovery tank.
6
7000S FLOOD HOG™ PARTS & PRICING
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF MYTEE PRODUCTS, INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF MYTEE PRODUCTS, INC. IS PROHIBITED.
ITEM NO.
ITEM NO.
Order parts at: www.mytee.com
7
Part prices are subject to change.
7000S FLOOD HOG™ PARTS & PRICING
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF MYTEE PRODUCTS, INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF MYTEE PRODUCTS, INC. IS PROHIBITED.
8
Float Switch
7000S FLOOD HOG™ WIRING DIAGRAM
Ground to metal plate
Pump Out
Float Switch
E-564
9
GENERAL INFORMATION
Dear Customer:
Congratulations on the purchase of your new 7000S Flood Hog™. As you are already aware, the scene of the equipment world is becoming more high tech, and we at Mytee Products Inc. strive to keep you on the cutting edge with superior quality and technology.
Keep in mind that the 7000S Flood Hog™ is a machine, so neglect or abuse will cause unnecessary damage and void the warranty. However with simple maintenance the Flood Hog™ will give quality performance for many years to come.
If warranty questions arise, please consult your user manual or get in touch with your distributor. If you have questions about maintenance, replacing parts or ordering parts, please call an authorized Mytee Products Inc. Service Center.
To see an updated list, visit our website at www.mytee.com
Before you begin cleaning, please read your manual thoroughly.
Sincerely,
Mytee Customer Care Dept.
Grounding Instructions
This machine must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for electrical shock. This machine is equipped with a cord having an equipment-grounding conductor and grounding plug. The plug must be plugged into an appropriate outlet that is properly installed in accordance with all local code and ordinances. Do not remove ground pin; if missing, replace plug before use.
Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the machine. If it will not fit the outlet, have a proper outlet installed by a qualified electrician.
This appliance is for use on a nominal 120-volt circuit, and has a grounding plug that looks like the plug illustrated in Figure 1 below. A temporary adapter illustrated in Figures 2 and 3 may be used~to connect this plug to a 2-pole receptacle as shown in Figure 2 if a properly grounded outlet is not available. The temporary adapter should be used only until a properly grounded outlet (Figure 1) can be installed by a qualified electrician. The green colored rigid ear, tab or the like extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box cover. Whenever the adapter is used, it must be held in place by a metal screw. Grounding adapters are not approved for use in Canada.
Replace the plug if the grounding pin is damaged or broken.
The green (or green-yellow) wire in the cord is the grounding wire. When replacing a plug, this wire must be attached to the grounding pin only.
DO NOT use extension cords.
Please Note for America use only
Grounded Outlet
Metal
Screw
Grounding Pin
Figure 1
Grounded Outlet Box
Figure 2
Adapter
Tab for Grounding
Screw
Figure 3
Parts and Service
Repairs, when required, should be performed by Mytee service personnel or Mytee authorized Service Center using Mytee original replacement parts and accessories.
Call Mytee for repair parts or service. Please specify the Model and Serial Number when discussing your machine.
Name Plate
The Model and Serial Number of your machine are shown on the Nameplate on the back panel of the machine. This information is needed when ordering repair parts for the machine. Use the space provided on the front cover to note the Model and
Serial Number of your machine for future reference.
Unpacking the Machine
When the machine is delivered, carefully inspect the shipping carton and the machine for damage. If damage is evident, save the shipping carton so that it can be inspected by the carrier that delivered it. Contact the carrier immediately to file a freight damage claim.
Caution and Warnings
Symbols
Mytee uses the symbols below to signal potentially dangerous conditions. Always read this information carefully and take the necessary steps to protect personnel and property.
Is used to warn of immediate hazards that will cause severe personal injury or death.
Is used to call attention to a situation that could cause severe personal injury.
Is used to call attention to a situation that could cause minor personal injury or damage to the machine or other property. When using an electrical appliance, basic precautions should always be followed, including the following: Read all instructions before using this machine. This product is intended for commercial use only.
To reduce the risk of fire, electrical shock, or injury:
1. Read all instructions before using equipment.
2. Use only as described in this manual. Use only manufacturer’s recommended attachments.
3. Always unplug power cord from electrical outlet before attempting any adjustments or repairs.
4. Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
5. Do not pull by cord. Do not close a door on cord or pull cord around sharp edges or corners.
6. Do not run appliance over cord. Keep cord away from heated surfaces.
7. Do not use with damaged cord or plug. If cord is damaged, repair immediately.
8. Always unplug or disconnect the appliance from power supply when not in use.
9. Do not allow to be used as a toy. Close attention is necessary when used by or near children.
10. Do not use in areas where flammable or combustible material may be present.
11. Do not leave the unit exposed to harsh weather elements. Temperatures below freezing may damage components and void warranty.
12. Use only the appropriate handles to move and lift unit. Do not use any other parts of this machine for this purpose.
13. Keep hair, loose clothing, fingers, and all parts of the body away from all openings and moving parts.
14. Use extra care when cleaning on stairs.
15. To reduce the risk of fire or electric shock, do not use this machine with a solidstate speed control device.
16. The voltage and frequency indicated on the name plate must correspond to the wall receptacle supply voltage.
17. When cleaning and servicing the machine, local or national regulations may apply to the safe disposal of liquids which may contain: chemicals, grease, oil, acid, alkalines, or other dangerous liquids.
18. Do not leave operating unattended.
Pre-Operation
1. Remove furniture and other items from the area you are going to treat.
2. Make sure debris filter is clear and electrical cord is in good repair.
3. Make sure a 20A grounded wall outlet is available for cord. Do not use extension cord.
Operation
1. In front, attach one end of the first vacuum hose to a wand (using scalloped or squeegee vacuum head), the other end to the Cuff-Lynx™ hose connection on the front of the machine.
2. The debris filter inside the machine protects the vacuum motor from damaging debris. Keep it clean by removing vacuum hose and turning the top latch counterclockwise and opening the lid. Remove stainless steel basket and gently rinse with water. Dry with a soft cloth. Replace basket, lid and hose.
3. In back, attach the second vacuum hose bearing cam lock to the Auto Pump-out fitting. Secure the hose to the fitting using the cam lock. Push the hose cuff onto the fitting, making sure the silver ears and rings are extended forward. Pull the ears
10
down using the rings until connection is tight. Place the end of the hose in a location where dirty water can drain.
4. Two power cords are located in the back of the machine. To power Vacuum 1 and
Pump, plug in the top cord. To power the Vacuum 2, plug in the bottom cord. Plug each of the two power cords into two separate, 20A grounded wall outlets. Do not use extension cords.
5. Three switches are located on the lower left side of the machine. To use the vacuum 1, turn on the Vacuum 1 switch. To use Vacuum 2, turn on the Vacuum 2 switch. To use the pump, turn on the Pump switch.
6. Place wand over flooded area and begin extracting.
7. If pump must be accessed during extraction, use the recovery tank lid on top of the machine. Pull the lever up and turn counter clockwise until it faces the side of the machine. Pull up and take the lid off. Use reverse procedure to replace.
8. When the job is finished, turn off switches and unplug power cords. Remove hoses.
After Use
1. Unplug.
2. Inspect hoses and replace if damaged.
3. Inspect filter and clean.
4. Open recovery tank to promote air circulation
5. Make sure machine and hoses are completely drained and dry.
6. Store the machine in a clean, dry place.
Maintenance Schedule
Maintenance item Daily Once a week
Clean and inspect Tanks
Clean and inspect Hoses
Inspect filters
Check electrical cord
Clean machine with all purpose cleaner and cloth
Inspect vacuum hoses for holes and loose cuffs
Lubricate wheels with water-resistant oil
Inspect machine for water leaks and loose hardware
Trouble Shooting
x x x x x x x x
There is no power.
1. Plug machine in proper outlet.
2. Check circuit breaker; reset circuit breaker, other items should not run on the same circuit as machine. Outlet must be a 20-amp circuit. For 7000S models, two separate 20-amp circuits are required.
Pump does not work properly.
1. Check pump wire. May need to reconnect wire.
2. Switch plate switch may need to be replaced.
3. If pump motor brushes are worn, replace pump.
4. Float switch obstructed. Clean.
Vacuum motor does not work properly.
1. Check that hose is tightly connected.
2. Close drain hose valve completely.
3. Secure the vacuum tank tightly.
4. If water is coming out of vacuum motor, use a low foaming detergent.
FAQs
Q: How much does the 7000S weigh and what are the shipping dimensions?
A. 7000S weighs 124 pounds - Box dimensions are 20” x 30” x 48”. Must ship motor freight.
Q: What comes standard with the 7000S?
A: The 7000S comes with two 25’ vacuum hoses (H294), a wand (H908), a vacuum head (P570), a squeegee vacuum head (G200) a 2” x 1.5” Cuff Lynx™ (H141), two
2” Cuff-Lynx™ plugs (H121), and pack of filters (G008).
Q: Where do I plug the machine in?
A: Plug each power cord into a separate, 20A grounded wall outlet. Outlets must
be on two separate breakers. When the amber light on the switch plate illuminates, the machine is on separate circuits (not necessarily 20A circuits). You can identify the primary cord by the yellow tag.
Q: Is there anything I can do to increase the expected life of my machine?
A: Running the vacuum motors with the tank empty and lid off will allow excess moisture in the vacs to dry off.
11
GENERAL INFORMATION
NOTES
Mytee Products Inc.
13655 Stowe Dr.
Poway, CA 92064 www.mytee.com
FX 858.679.7814
© 2015 Mytee Products Inc.
Printed in the U.S.A.
12
advertisement
Key Features
- Heavy Duty
- Auto Pump-out
- Dual Vacuum System
- 35 GPM Pump
- Can be used as booster
- Debris filter