Zamp solar 12-Volt DC to AC 300-Watt Pure Sine Wave Inverter User manual

Zamp solar 12-Volt DC to AC 300-Watt Pure Sine Wave Inverter User manual

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Manual
Zamp solar 12-Volt DC to AC 300-Watt Pure Sine Wave Inverter User manual | Manualzz
ZAMP
SOLAR
power to explore!
User Manual for Zamp Solar Pure Sine-Wave Power Inverters
ZS-300PS
ZS-600PS
ZS-1000PS
ZS-2000PS
Specifications
item ZP-300PS | ZP-600PS | ZP-1000PS | ZP-2000PS
Continuous output frequency 300W 600W 1000W 2000W
Surge power 600W 1200W 2000W 4000W
Input voltage range (12V) 10~15VDC
Input under voltage activation
(12V) 10.6VDC
Input under voltage protection
i? HER 10VDC
(12V)
Input over voltage protection 15VDC
(12V)
Input voltage 12V
Output voltage 120V AC+10%
Output frequency 60Hz +1Hz
Output waveform Pure sine wave ( THD=: 3%)
Conversion efficiency 90%
Overload protection Yes
Thermal protection 65C+5C
Use of advanced
; Yes
microprocessor control
USB Output 5 VDC, Max 1A (Max 2A only for model
ZP-2000PS)
Display LED indicator
Length of the remote 15 ft. (4.6m) only for model ZP-1000PS
controller wire & ZP-2000PS
Intelligent cooling The fan starts to work when The cooling fan on the
. product will not run when
the load EES larger than start up the inverter,it will
100W,does not work when start running only
no load or small load. when the case
temperature reaches
about 40°C.
Fuse(outer car fuse) 40A 40Ax2 40Ax4 40Ax8
Dimension(LxWxH) 187x95x55mm | 213x140x74mm | 293x140x74mm | 435x236x95mm
Weight 0.69Kg 1.67Kg 2.42Kg 5.15Kg
Working temperature 0C-40'€
Storage temperature -10'C~457C
1. BRIEF:
Our power inverter is an advanced tool of power conversion, and it can supply you with AC power
converted from DC power source. Not only can be used in cars, vessels and camping, but also
can be used in emergency when power fail.
In order to use the inverter efficiently and safely, please install and use it in a proper way. Please
read the instruction carefully before installing and using the appliance.read the instruction carefully
before installing and using the appliance.
2. WARNING AND SAFETY
1) Read the manual before use and keep it for future reference.
2) Don't put the inverter under sunshine, nearby heating source, drench or humidity environment
3) The case housing of inverter will be calorific when using, please avoid touching the material
that can't stand of high temperature, such as clothes, sleeping bag and carpet.
4) Our power inverter is designed to use with the negative ground electrical system! Don't use
with positive ground electrical systems (The majority of modern automobiles, RVs, trucks and
boats are negative ground).
5) Do not disassemble the unit random, it may cause fire or electric shock.
6) Keep inverter away from children and don't allow them to play with the unit.
7) The power inverter will output AC power as utility power, please treat the output terminal as
carefully as your home AC socket. Don't put any other things into the output terminal except
electrical appliance plug. It will bring danger or fire if using in a wrong way.
8) Disconnect the battery and inverter when no use.
3. PARTS LIST
AC OUTPUT O
= 000 AC pu
000 a |
000000000 ой
Ou || indicator
о 000000000 5
> UN -
Positive NW 2) Negative
Fan (Vents) (Only for ZP-300PS )
USB Port
USB Port —
LED protect
indicator — |
LED power —
indicator
Switch
Positive >
Fan (Vents)
Fuseholder — a
Negative
(Only for ZP-600PS )
-
©
0
USB Port INN © —
Е
Wired remote
port
—
> AC output
| m
LED protect o EJ socket
indicator |
fit Je © С > С E J
LED power | g "e С
indicator
Switch
Positive __ |
Fan (Vents)
T=
Negative
anis
Power switch
Interface of remote
controller with wire
Connecting wire-——
; (Remote control box) (for ZP-1000PS & ZP-2000PS)
USB Port
Wired remote
port
Positive >
NE 97
2-9 SI,
Negative
Fan (Vents)
4. INSTALLATION
1. The requirements of the installation location.
Ensure there is enough space for the installation,and the location should according
to the following requirements:
1) Dryness: never drop water or other liquids on the inverter
2) Coolness: the ambient temperature should be 0-40'C, and the perfect temperature
is 10-25'C. The lower the better in this range of the ambient temperature.
3) Ventilation: there should be a certain distance between the unit and the surrounding
appliance, do not obstruct the vents
La 4. Cleanness: do not install the unit in the place with dusty, timbering residue or particle
which may be brought into the product when the cooling fan works and may influence
the normal operation
5. There will be some electrical arcing or spark when the inverter connects with the
battery, so the combustible materials should not be around, such as gasoline, alcohol
etc.
2. Installation of inverter
Since the weight is very heavy,it's better to put the inverter on a stable space, such as
floor, table or fixed kickstand etc.Make sure that the kickstand can bear the weight od
the ivnerter,and fix the product with four screws,to avoid dropping.
1) Open the cover of remote
control box.
3) Close the cover of
remote control box
2) Fix the bottom of the remote
control box on suitable place,
such as wall,tabletop etc.
4) If simplely fixed to a vertical plane,firstly
fix two screws in the position of 40mm
apart on the plane, then hung up the ]
remote control box on it. |
5) Connect the cable between the
remote control box and inverter.
Indication: This product can be used as normal pure sine wave inverters even not
connect to the remote control box
5. USAGE
1. How to use inverter
1. Check the output voltage and capacity of the battery,it should comply with the requirement
of the product use.
2. Connect the battery and the DC cable of the inverter,ensure that the polarities can not be
reversed and in good contact.
3. Turn on the switch, the green LED power indicator is on
4. Turn off electrical appliances and insert electrical appliance plug to the AC output socket of
inverter. Tum on electrical appliance for using.
5. After finish, turn off electrical appliance and inverter,disconnect inverter with battery if not
use for long time.
2. How to use inverter (Only for ZP-1000PS & ZP-2000PS)
1.Check the output voltage and capacity of the battery, it should comply with the
requirement of the product use.
2.Connect the battery and the DC cable of the inverter,ensure that the polarities can not
be reversed and in good contact.
3.Long press the power switch on the inverter or the remote control box for more than
0.5 seconds then release,the power indicator on the inverter and remote control box
are on,the inverter start to work.(Open the inverter by this way can effectively avoid
Interference or mistakenly boot)
4. Turn off electrical appliances and insert electrical appliance plug to the AC
output socket of inverter. Turn on electrical appliance for using.
5. The cooling fan on the product will not run when start up the inverter,it will start
running only when the case temperature reaches about 40 “C.
6) When not in use,press the power switch on the inverter or remote control box,
the power indicator is off, neans the inverter has shut down.Inverter will not
consume the battery current in shutdown state.
3. How to use USB power supply
This model with USB output,can provide stable 5V DC voltage, the maximum current is
1000mA (ZP-2000PS maximum current is 2000mA), can directly provide power for the
portable device with USB port.
Notice: Before use the USB power supply. please make sure the device can be charged
by USB and the maximum working current is no more than 1000mA (ZP-2000PS the
maximum working current is no more than 2000mA).
6. BATTERY OPERATING TIME
Battery operating time depends on battery capacity (AH) and load power (W), the calculation
formula of operating time is:battery capacity (AH) x battery output voltage(V) +load power
(W)
For example:battery specification:12V 200Ah,load power is 600w,then the operating time is :
200x 123008 hours
7. SOFT START TECHNOLOGY
The unit has the latest soft start technology, that is, the output voltage gradually increases
to the normal value from low value after turn on the inverter. It can reduce the transient
large current attack and help to start the hard start load
For large power inductive load, such as electrical motor or capacitive loads such as Large
Power SMPS adopt soft start. Please tum on the switch of load, then turn on the switch
of inverter.
8. OUTPUT VOLTAGE & WAVEFORM
The output waveform of the inverter is pure sine wave, which has the same waveform
of the sine utility power,even higher than the purity of the domestic power. This kind of
waveform is suitable for most electrical appliances, including linear and switching in
electronic equipments, transformers, motor etc.Compare with modified sine wave inverters,
the power factor and power utilization of electric fans, refrigerators and other inductive
loads can be improved by using pure sine wave inverter,and the noise during appliance
operating can be effectively reduced too.
Pure Sine Wave Output
(120 VAC Model)
9. FUNCTION
1. Input under-voltage alarm: When the input DC voltage is lower than 10.6V, the buzzer
will whistle intermittently to remind that the inverter will go into the under voltage protection.
Pay attention to save the data if you are using computer.
2 .Under voltage protection: The inverter will automatically shut down when the input
DC voltage is lower than 10V.The buzzer will whistle continuously and the green light is
off red light on. Please turn off the inverter and use it after recharge the battery.
3. Over voltage protection: The inverter will automatically shut down when the input
DC voltage is higher than 15V.The buzzer will whistle continuously and the switch indicator
light is on. Please turn off the inverter and adjust the input voltage to the admissible
range.
4. Overload protection: The inverter will automatically shut down when the load power
is higher than the rated power. The buzzer will whistle continuously. Turn off the inverter
and resume to normal operation after taking away the redundant load.
5. Thermal protection: The unit will be calorific during operation. If the temperature is
higher than 65°C, the inverter will automatically shut down. Then the buzzer will whistle
continuously and the green light is off,red light is on. Please turn off the inverter, and
continue using it after the temperature goes back to normal temperature naturally.
Meanwhile find out the factors caused the fault, such as ventilation, ambient temperature,
vent, load power and so on. It can avoid the similar things happen after check it.
10.
TROUBLESHOOTING TIPS
Fault/Display Cause | Solutions
Fault/Display |
Cause
Solutions
No output voltage,
buzzer sounds
continuously
Low input DC voltage
Recharge or replace the |
battery
High input DC voltage
Do not use it when the
battery is charging. Check
the rated voltage of the
battery and make sure
that it is in the allowable
range of the input voltage
Disturbance 1.Separate the inverter
and antenna.
2.Use screened antenna
When using with
TV or audio,
There snowflake
on the screen or
noise of the audio
Overload
Reduce the load power.
Over temperature
Cut off the load and keep
it cool naturally for 10 to
30 minutes. Restart it after
it resume to nomal
temperature. The load
power is too large and
reduce the total load
power to the range of
rated power. Avoid
blocking the vent and
improve the ventilation
condition. Reduce the
ambient temperature.
No output voltage
|. The switch is off.
2. The battery lead doesn't
connect well
1.Turn on the power switch.
2.Check the joint and make
sure it's well connected.
Incorrect output
voltage
1. RMS Multimeter
measurement error
2. The battery power of RMS
Multimeter is low
The input voltage is too
high or too low
1. Use the true RMS
multimeter to measure,
such as the model FLUKE
177/179.
2.Try to maintain the input
voltage in the range of rated
power
3.Change the battery of the
multimeter then test again.
Cannot drive
the load
1. Load power is too large,
or the actual power of the
appliance exceeds nominal
power.
2. The starting power is
larger than rated power
(such as motor)
1. Reduce the load power,
or open the appliance first,
then open the inverter,
The inverter internal
soft-start circuit to buffer
start the appliances.
If inverter still cannot work normally after solutions mentioned above are tried, please
return inverter to supplier for repairing. The internal parts may be damaged.
11. WARRANTY
We take the quarantee of one year from the purchasing day. During the guarantee period,
any malfunction caused by our product quality, our company will fix the unit for free. But
any one of the following conditions is beyond our guarantee terms.
1. The box distorted, damaged or changed, and interior parts damaged because of the
exterior hit or drop.
2. Connect the DC power adversely.
3. Dismantled or repaired the unit by un-granted person.
4. The unit was damaged by incorrect installation or operating method.
WWW.ZAMPSOLAR.COM

advertisement

Related manuals

Download PDF

advertisement