Viking Access Systems R-6 Gate Opener INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION
Below you will find brief information for Gate Opener R-6 R-6. The R-6™ swing gate operator is capable of handling gates up to 700 lbs. and 14 ft long. With its efficient drivetrain, robust stature, built-in battery backup, soft start/soft stop and adaptive algorithm, The R-6™ gate operator is the ideal choice for residential applications.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
INSTALLATION
INSTRUCTIONS
AND SAFETY INFORMATION
F O R T H E V I K I N G R- 6 G AT E O P E R ATO R
Residential Vehicular
Swing Gate Operator
The R-6™ swing gate operator is capable of handling gates up to
700 lbs. and 14 ft long. With its effi cient drivetrain, robust stature, built-in battery backup, soft start / soft stop and adaptive algorithm,
The R-6™ gate operator is the ideal choice for residential applications.
THE VIKING R-6™ SWING GATE OPERATOR
R-6 Vehicular Gate Operator • Revision R6NXMN10.F • February 2016
2
PARTS DIAGRAM:
Item Description
1 Operator Cover Bolt (4)
2 Operator Cover
3 Output Shaft Knob
4 Output Shaft Cover
5 Clutch Key
6 Clutch and Handle
7 Output Arm
8 Output Shaft
9 Limit Cam & Holder
10 Limit Switch (2)
11 Limit Switch Holder
12 Control Board
13 Fuse - 15 amp
14 Fuse - 4 amp
15 Worm Gear #60 Ratio 30:1
16 Alarm
17 Toroid Transformer - 10 amp
18 Battery
19 Motor Switch
20 Battery Switch
21 Chassis
22 Sprocket (Gearbox)
23 Chain #40x38 Pitches
24 Sprocket (Motor)
25 24V DC Gearhead Motor
26 Brush Kit
27 120V Receptacle
28 Power Supply Panel Assembly
29 Main Power Switch
30 Power Harness
31 Limit Switch Harness
32 Multi-Part Arm Assembly
DUBA12
DUMRS10
DUMRS10
VNXR6CH
VASP1034
R6CHN40
DWLH10
VFLEXPCBU16
VNXF15A
VNXF4A
R6GB60
DUAL10
DUTT10
VASP1058
VAR6MO
VAMBK
VA120PL
VNXR6PSPA
DUMRS10
VNXR6PH
VNXR6LSH
VA-F1ARM20
Part No.
VASWCB
VAR6CO20
DWOUK10
DWOC20
VAWRCK20
DWCL20
DWAR20
R6OPS20
DWLC10
DULS10
VIKING TECHNICAL SUPPORT 1.800.908.0884
OPERATOR REFERENCES:
1. COVER BOLTS
2. OUTPUT SHAFT COVER (HAT)
3. OUTPUT SHAFT KNOB secures Hat; remove to access manual release
4. MAIN COVER ASSEMBLY
5. MANUAL RELEASE HANDLE releases the clutch to allow for manual operation
KEY install if application does not require clutch to slip; remove to manually operate the gate
7. OUTPUT ARM connects the Arm Assembly to Clutch & Handle
Assembly
8. VFLEX CONTROL BOARD
9. MOTOR SWITCH discontinues power to the motor; also serves as a breaker that will self-trip to protect the motor circuitry
SWITCH disconnects batteries from the charging circuit during troubleshooting
11. J-BOX high voltage power supply connection
12. POWER SUPPLY PANEL ASSEMBLY convenient access to main power supply switches, status indicators and EMI Fuse
VIKING TECHNICAL SUPPORT 1.800.908.0884
3
CONTROL BOARD REFERENCES:
4
1. POWER HARNESS CONNECTOR provides power to the control board. pg 18-19
2. “OPEN LEFT” & “OPEN RIGHT” provides power to the motor. pg 20
3. LIMIT SETUP BUTTONS available for future developments.
4. FEATURE ACTIVATION TRIM POTS activate and set features. pg 24
5. “EPS1” CONNECTOR available for future developments.
6. “EPS2” CONNECTOR available for future developments.
7. EMI BOARD CONNECTOR monitors the high voltage power supply.
8. “CHECK MOTOR” Status LED indicates motor power status. pg 36
9. “BATTERY LOW” Status LED
indicates battery power status. pg 36
10. “POWER” Status LED control board power status. pg 18,36
11. “MAGNETIC LOCK RELAY” Status LED status of this on-board relay. pg 34, 36
12. “MAGNETIC LOCK RELAY” Terminal Block
connect electric locks here. pg 34, 36
13. INPUT STATUS LEDs indicates input status. pg 36-37
14. ACCESS CONTROL TERMINAL BLOCKS accessory connections. pg 29-32, 42-44
15. “MASTER/SLAVE” Terminal Block wired master/slave connection. pg 22
16. CONTROL BOARD MOUNTING HOLES secures and grounds the control board.
17. “Siren” Terminal Block
Vikings UL Siren is connected here.
18. ON-BOARD 3 BUTTON STATION controls the gate during set up.
19. “AUX. PWR” Terminal Block used for solar applications & in-motion warning devices. pg 19, 25
20. FEATURE ACTIVATION PIN HEADERS activate features by placing a jumper onto the pin headers. pg 25
21. “DIAGNOSE” Button allows you to navigate through the
Diagnostics LCD Display. pg 38-40
22. “DIAGNOSE” LED informs that errors have been detected and available on LCD Display. pg 38-40
23. LCD DIAGNOSTICS DISPLAY provides error messages, diagnostics and operator status information. pg 38-40
24. EXPANSION PRODUCT CONNECTIONS connections for additional products from Viking Access Systems. pg 46
25. “FAIL SAFE/SECURE” Jumper available for future developments
26. FUSE HOLDER - 15 AMP for motor circuit.
27. FUSE HOLDER - 4 AMP for charging circuit.
28. HEAT SINK secures the control board and dissipates heat.
VIKING TECHNICAL SUPPORT 1.800.908.0884
PARTS DIAGRAM/PARTS LIST
OPERATOR REFERENCES
CONTROL BOARD REFERENCES
Maintenance
TABLE OF CONTENTS:
3 3
2 2
8
13
14-17
Operator Positioning; Arm Assembly 16-17
MASTER/SLAVE SET UP
CONTROL BOARD SETUP
Obstruction Detection Sensor (Primary Entrapment Protection) 26
Heater, Lock Mode................................................................................................................. 27
Radio Receiver (Typical) 30
Viking Loop Rack 32
LED References 36-37
LCD Display References 38-40
42-45
VIKING EXPANSION PRODUCTS
VIKING TECHNICAL SUPPORT 1.800.908.0884
5
6
IMPORTANT SAFETY INFORMATION
!
WARNING! Not Following these instructions may cause severe injury or death.
IMPORTANT SAFETY INSTRUCTIONS
!
WARNING! To reduce the risk of severe injury or death.
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. Never let children operate or play with gate controls. Keep the remote away from children.
3. Always keep people and objects away from the gate. NO ONE SHOULD
CROSS THE PATH OF THE MOVING GATE.
4. Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or when an object activates the non-contact sensors. After adjusting the force or the limit travel, retest the gate operator. Failure to adjust and retest the gate operator properly can increase the risk of injury or death.
5. Use the emergency release only when the gate is not moving.
6. KEEP GATES PROPERLY MAINTAINED. Read the user’s manual. Have a qualified service person make repairs to gate hardware.
7. The entrance is for vehicles only. Pedestrians must use a separate entrance.
8. Every gate operator installation MUST have secondary protection devices against entrapment, such as edge sensors and photo beams more in particularly in places where the risk of entrapment is more likely to occur.
9. SAVE THESE INSTRUCTIONS.
IMPORTANT INSTALLATION INSTRUCTIONS
1. Install the gate operator only when: a. The operator is appropriate for the construction of the gate and usage
Class of the gate (refer to page 9), b. All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 6 feet (1.83 m) above the ground to prevent a 2-1/4 inch (57. 2 mm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position, c. ALL EXPOSED PINCH POINTS ARE ELIMINATED OR GUARDED, AND d. GUARDING IS SUPPLIED FOR EXPOSED ROLLERS.
2. The Operator is intended for installation only on gates used for vehicles.
Pedestrians must be supplied with a separate access opening. The pedestrian access opening shall be designed to promote pedestrian usage. Locate the gate such that persons will not come into contact with the vehicular gate during the entire path of travel of the vehicular gate.
3. The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open in to the public access areas.
4. The gate must be properly installed and work freely in both directions prior to the installation of the gate operator. Do not over-tighten the operator clutch or pressure relief valve to compensate for a damaged gate.
5. The gate operator controls must be placed so that the user has full view of the gate area when the gate is moving AND AWAY FROM THE GATE PATH
PERIMETER.
VIKING TECHNICAL SUPPORT 1.800.908.0884
IMPORTANT SAFETY INFORMATION
!
WARNING! Not Following these instructions may cause severe injury or death.
IMPORTANT INSTALLATION INSTRUCTIONS (Continued)
6. Controls intended for user activation must be located at least six feet (6’) away from any moving part of the gate and where the user is prevented from reaching over, under, around or through the gate to operate the controls.
Exception: Emergency access controls only accessible by authorized personnel
(i.e. fire, police, EMS) may be placed at any location in the line-of-sight of the gate.
7. The Stop and/or Reset button must be located in the line-of-sight of the gate.
Activation of the reset control shall not cause the operator to start.
8. A minimum of two (2) WARNING SIGNS shall be installed, in the area of the gate. Each placard is to be visible by persons located on the side of the gate on which the placard is installed.
9. For gate operators using non-contact sensors (photoelectric beam or like) in accordance with section 31.1.1 of the UL standard:
a. See instructions on the placement of non-contact sensors for each type of application (refer to page 10).
b. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle, trips the sensor while the gate is still moving, and c. One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable by a moving gate or barrier (refer to page 10).
d. Use only Miller Edge photoelectric beams (refer to pages 10-11).
10. For a gate operator utilizing a contact sensor (edge sensor or like) in accordance with section 31.1.1 of the UL 325 standard:
a. One or more contact sensors shall be located where the risk of entrapment or obstruction exists, such as a the leading edge, trailing edge, and post mounted both inside and outside of a vehicular horizontal slide gate (refer to page 10).
b. One or more contact sensors shall be located at the bottom of a vehicular vertical lift gate.
c. One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate.
d. A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subject to mechanical damage.
e. A wireless contact sensor such as one that transmits radio frequency
(RF) signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstructions. A wireless contact sensor shall function under the intended end-use conditions.
f. One or more contact sensors shall be located on the inside and outside leading edge of a swing gate. Additionally, if the bottom edge of a swing gate is greater than 6 inches (152 mm) but less than 16 inches (406 mm) above the ground at any point in its arc of travel, one or more contact sensors shall be located on the bottom edge.
g. One or more contact sensors shall be located at the bottom edge of a vertical barrier (arm).
h. Use only Miller Edge edge sensor (refer to pages 10-11).
7
VIKING TECHNICAL SUPPORT 1.800.908.0884
8
IMPORTANT SAFETY INFORMATION
!
WARNING! Not Following these instructions may cause severe injury or death.
MAINTENANCE
Remove the Power Harness from the Control Board. (refer to page 18)
• Clean and lubricate the turning pins and gate hinges using the recommended lubricant.
• Check that all hardware of the gate operator is properly tighten.
• Ensure that the gate moves freely.
• Check for corroded parts and replace if necessary.
• Check the battery for the following:
- Battery connections must be free of corrosion.
- Battery voltage must be 26VDC (fully charged battery).
Reconnect the Power Harness for the Control Board. (refer to page 18)
• Check and confirm the proper operation of all safety devices (photoelectric eye, edge sensors or like).
• Check and confirm the operation of all installed accessories.
• Check and confirm the operation of all special features such as the Intelligent
Obstruction Sensor, Hold Open Timer. (refer to page 24 and 26)
• Check and confirm the operation of the manual release. (refer to page 11)
• Verify the functionally of the battery backup, or power failure option, by turning off the main power source (115VAC or 230VAC).
DO NOT FORGET TO
TURN ON THE MAIN POWER SOURCE AFTER VERIFICATION.
GENERAL SAFETY PRECAUTIONS
The following precautions are an integral and essential part of the product and must be supplied to the user. Read them carefully as they contain important indications for the safe installation, use and maintenance.
• These instruction must be kept and forwarded to all possible future users of the system.
• This product must be used only for that which it has been expressly designed.
• Any other use is to be considered improper and therefore dangerous.
• The manufacturer cannot be held responsible for possible damage caused by improper, erroneous or unreasonable use.
• Avoid operating in the proximity of the hinges or moving mechanical parts.
• Do not enter the path of the moving gate while in motion.
• Do not obstruct the motion of the gate as this may cause a situation of danger.
• Do not allow children to play or stay within the path of the moving gate.
• Keep remote control or any other control devices out of the reach of children, in order to avoid possible involuntary activation of the gate operator.
• In case of break down or malfunctioning of the product, disconnect from the main power source. Do not attempt to repair or intervene directly, contact only qualified personnel for repair.
• Failure to comply with the above may create a situation of danger.
• All cleaning, maintenance or repair work must be carried out by qualified personnel.
• In order to guarantee that the system works efficiently and correctly it is important to have the manufacturer’s instructions on maintenance of the gate and operator carried out by qualified personnel.
• In particular, regular checks are recommended in order to verify that the safety devices are operating correctly.
All installation, maintenance and repair work must be documented and made available to the user.
VIKING TECHNICAL SUPPORT 1.800.908.0884
IMPORTANT SAFETY INFORMATION
!
CAUTION: To Reduce the Risk of Fire or Injury to Persons: a. Use only the following type and size battery(ies): Yuasa NP7-12 or VIKING DUBA12 b. Do not dispose of the battery(ies) in fire. The cells may explode. Check with local codes for possible disposal instructions.
c. Do not open or mutilate the battery(ies). Released electrolyte is corrosive and may cause damage to the eyes or skin. It may be toxic if swallowed.
d. Exercise care in handling batteries in order not to short the battery with conducting materials such as rings, bracelets and keys.
e. Change the battery(ies) provided with or identified for use with this product only in accordance with the instructions and limitations specified in this manual.
f. Observe proper polarity orientation between the battery(ies) and charging circuit.
g. Do not mix batteries of differ ant sizes or from different manufactures in this product (applies to products employing more than one user replaceable secondary battery).
h. A battery-operated product employing a secondary battery supply intended to be charged within the product shall contain specific instructions concerning the proper method of charging.
UL325 Gate Operator Classifications
GLOSSARY
RESIDENTIAL VEHICULAR GATE OPERATOR
CLASS I -
A vehicular gate operator (or system) intended for use in garages or parking areas associated with a residence of one-to four single families.
COMMERCIAL/GENERAL ACCESS VEHICULAR GATE OPERATOR
CLASS II –
A vehicular gate operator (or system) intended for use in a commercial location or building such as a multi-family housing unit (five or more single family units), hotel, garages, retail store, or other building servicing the general public.
INDUSTRIAL/LIMITED ACCESS VEHICULAR GATE OPERATOR
CLASS III –
A vehicular gate operator (or system) intended for use in an industrial location or building such as a factory or loading dock area or other locations not accessible by or intended to service the general public.
RESTRICTED ACCESS VEHICULAR GATE OPERATOR
CLASS IV –
A vehicular gate operator (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel.
Install the gate operator only when:
The operator is appropriate for the construction of the gate and the Usage Class of the gate.
VIKING TECHNICAL SUPPORT 1.800.908.0884
9
IMPORTANT SAFETY INFORMATION
!
WARNING! Not Following these instructions may cause severe injury or death.
Secondary Entrapment Protection Requirements
IMPORTANT:
SECONDARY PROTECTION MUST BE INSTALLED
• REQUIRED BY UL 325, an approved MONITORED secondary entrapment protection sensor is REQUIRED to be installed in all areas accessible to potential entrapment and pinch points.
• The installed sensor MUST be
“10K Resistor Based”.
• At least ONE monitored sensor MUST be connected.
• You may connect up to FOUR monitored sensors, wired parallel.
• Failure to install an approved monitored secondary entrapment protection sensor will render the gate operator INOPERABLE until one is installed.
• Consult the installation manual of the sensor for detailed information about the usage, installation and maintenance.
• This type of installation will only reverse the gate approximately 12” in the opposite direction it was traveling when the sensor is triggered.
• This type on installation is to protect against entrapment only and DOES NOT reverse the gate all the way back to its limits when the photo beam is obstructed.
• The following devices comply with UL 325 and have been tested for use with Viking
Access Systems gate operators.
Photoelectric Beam
(non-contact sensor)
MILLER EDGE: 10K Resistor based
model IG2
Edge Sensor
(contact sensor)
MILLER EDGE: 10K Resistor based
models ME110 through ME117, ME120 and ME123
Photo Beam (non-contact sensor)
Edge Sensor (contact sensor)
1 0
VIKING TECHNICAL SUPPORT 1.800.908.0884
IMPORTANT SAFETY INFORMATION
!
WARNING! Not Following these instructions may cause severe injury or death.
Secondary Entrapment Protection Installation
STEP 1
Connect the secondary entrapment protection sensor(s) to the Viking control board as illustrated. Up to four 10K resistor based sensors can be wired in parallel.
24VDC to Photoelectric Beam Emitter
To Photoelectric Beam Receiver and/or Edge Sensor monitored terminals
UL LEARN
SENSOR 1
STEP 2
Confirm the number of sensors connected:
• Toggle the “Diagnose” button until you see
UL
LEARN
on the LCD Display.
• Default setting is 1 sensor.
Proceed with the following
Learn Process:
• If the number of connected sensors does not match the display.
• If the “Stop” LED is flashing.
• If the error message
ERR UL
SENSOR
is displayed.
LEARN PROCESS
With the “UL LEARN” menu displayed and all secondary sensors properly connected to the control board:
• Press and hold the “Stop” button.
• Toggle the “Diagnose” button once.
• The correct number of sensors should now be displayed.
Manual Release
When manual operation is required:
1. Remove the “Output Shaft Cover” or Hat.
2. Lift the “Manual Release Handle”.
3. Remove the “Clutch Key”.
To resume normal operation:
1. Align the notches on the Output Shaft to the clutch and reinstall the Clutch Key.
2. Push the Manual Release Handle down, back to the locked position.
Refer to page 17 for more details
VIKING TECHNICAL SUPPORT 1.800.908.0884
1 1
IMPORTANT SAFETY INFORMATION
!
WARNING! Not Following these instructions may cause severe injury or death.
Audible Alarm Reset Switch Installation
Manual Reset for the Audible Alarm
• UL325 standard requires an audible alarm to sound after two consecutive events detected by the primary entrapment protection of the gate operator (obstruction sensor).
• The audible alarm will continue to sound for 5 minutes or until a stop command gets actuated.
• The Stop command can be actuated in two different forms:
1. Using the Built in Stop switch on the Control Board or;
2. Using an External Stop button within the sight of the gate, away from moving parts of the gate and out of reach of children.
a. Controls intended for user activation must be located at least six feet (6’) away from any moving part of the gate and where the user is prevented from reaching over, under, around or through the gate to operate the controls.
Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use.
b. The Stop and/or Reset button must be located in the line-of-sight of the gate.
Activation of the reset control shall not cause the operator to start.
2
Warning Placard Installation
• All Warning Placards must be installed where visible in the area of the gate.
• A minimum of two placards shall be installed.
• A placard is to be installed in the area of each side of the gate and be visible.
1 2
VIKING TECHNICAL SUPPORT 1.800.908.0884
IMPORTANT INSTALLATION INFORMATION
!
CAUTION: To Reduce the Risk of Fire or Injury to Persons:
!
WARNING: For use with gates at a maximum 700 lbs. in weight and 14 ft. in length.
DO NOT allow pedestrian use of this gate
Locate Control Buttons:
1. Within sight of the gate,
2. At a minimum height of 5 feet so small children are not able to reach it; and
3. At least 6 feet away from all moving parts of the gate.
DO NOT install the gate operator to lift gates
14 ft.
700 lb.
Specifications:
Maximum Gate Length:
Maximum Gate Weight:
Operating Temperature:
Power Requirements:
Alternative Power
14 ft.
700 lb.
-20°F (-28°C) to 160°F (71°C)
115VAC / 230VAC (5.5* Amp / 1.25 Amp)
*Includes 3 amp load on receptacle
Single Phase (50Hz / 60Hz)
24VAC / VDC (60VA) or Solar
VIKING TECHNICAL SUPPORT 1.800.908.0884
1 3
GATE OPERATOR INSTALLATION
Concrete Pad Option
1. Follow the local building code to determine the required depth of the concrete pad.
2. Pad measurements recommended by Viking Access Systems are at least
23” long, 20” wide and 30” deep to ensure the stable operation of the operator, and a minimum of 6” above level grade to avoid any flooding of the machinery.
3. Provide a sufficient number of conduit pathways for all low power accessories such as loop detector leads, maglock, non-contact sensors, contact sensors, safety and other commands. Also provide conduit for the power supply to the operator.
!
DO NOT run low voltage and high voltage wiring in the same conduit.
!
Provide at least 12” separation between low and high voltage conduits.
1 4
VIKING TECHNICAL SUPPORT 1.800.908.0884
GATE OPERATOR INSTALLATION
Post Mounting Option
TIP:
The operator can be post mounted to be elevated above snow and flood lines.
1. Consult the local building codes for the depth and concrete requirements.
2. Maximum 3.00” OD pipe.
3. Provide a sufficient number of conduit pathways for all low power accessories.
Also provide conduit for the power supply to the operator.
!
DO NOT run low voltage and high voltage wiring in the same conduit.
!
Provide at least 12” separation between low and high voltage conduits.
REQUIRED ADD-ON:
PART# VA-F1PS
• Main pieces made of 1/4” thick material
• All mounting hardware is included
• Posts and U-Bolts are not supplied
VIKING TECHNICAL SUPPORT 1.800.908.0884
1 5
GATE OPERATOR INSTALLATION
Operator Positioning
!
IMPORTANT: Swing Gates must not open into public access areas.
The gate must be installed in a location so that enough clearance is supplied between the gate, while opening and closing, and adjacent structures to reduce the risk of entrapment.
!
TECHNICAL TIPS:
Operator and Arm Geometry
• Increasing “C” dimension provides better gate control and stability by reducing the effects of inertia and deceasing the gate leverage against the operator.
• Following to the geometrical formulas and relationships provided is recommended.
Arm Assembly:
VA-F1ARM20
1 6
VIKING TECHNICAL SUPPORT 1.800.908.0884
GATE OPERATOR INSTALLATION
!
IMPORTANT:
When attaching the Arm Assembly to the gate, if the “Gate Bracket” is not welded to a frame member that runs the full length of the gate, the operator may damage the gate. Do not attach the Gate Bracket to only a few pickets.
STEP 1
Install the Clutch and cut the
Arm Assembly to achieve the desired dimensions for
“D” and “E” according to the formulas provided on page 16.
STEP 2
With the gate at the closed, install the Arm Assembly.
Check that the dimensions correspond accordingly to the formulas provided on page 16.
!
TIP:
Leave some additional material when cutting the Arm Assembly to allow for adjustment.
STEP 3
With the Clutch installed and released, manually move the gate to both limits.
Verify the following:
1. The gate reaches the desired limits.
2. The Arm does not bind at any point.
!
TIP:
Use C-clamps or tack-weld the Arm assembly in place until Step 3 has been completed.
STEP 4
Once satisfied with the installation and movement of the gate, weld the arm pieces securely. Paint the Arm to protect against rusting.
STEP 5
Rotate the Clutch until it lines up with the notches on top of the Output Shaft and insert the Clutch Key.
STEP 6
Verify the Clutch is adjusted properly.
• Both sides adjusted
evenly.
• Handle is locked, by hand, and positioned horizontally at 0°.
With the Clutch Key removed, the
Clutch should not slip with moderate force applied to the gate.
1 7
VIKING TECHNICAL SUPPORT 1.800.908.0884
ELECTRICAL INSTALLATION
High Voltage Supply Option
!
Caution:
Always turn off power breakers when working with high voltage. DO NOT connect the “Power Harness” to the Control Board until the electrical installation is complete and ready for verification.
STEP 1
At the “Power Supply Panel”:
a. Set the “Voltage Selector” according to the supply voltage (115V or 230V).
b. Turn the “AC Power” switch ON
1a
1b
3b
STEP 2
!
WARNING:
SINGLE PHASE AC ONLY
At the “J-Box”:
a. Connect the incoming power wires, matching the wire color codes.
b. If the supply voltage is 120VAC, connect the red wire, labeled “Outlet
Power”, to the neutral (white) wires.
2a
STEP 3
a. Turn ON the main facility breaker b. Verify that all three (3) LEDs are illuminated at the “Power Supply Panel”.
3c
c. Turn the “Battery Switch” ON.
At the Control Board:
d. Connect the Power Harness and verify the “POWER” LED is illuminated solid.
3d
!
TECHNICAL TIP:
If the “Power” LED is flashing or any of the 3 LEDs on the
“Power Box” are not illuminated, refer to the Troubleshooting pages.
Tips for proper ground installation:
To minimize the effects caused by lightning, follow these guidelines.
• Use a ground rod to provide a ground reference.
• Consult your city code and be aware of under-ground services in the site of the gate operator to prevent inconveniences.
• Always use a single bonding point for grounding.
• All ground wires must be as short and as thick as possible.
• Prevent unnecessary turns or loops in all ground wires.
1 8
Earth Ground
Ground Rod
VIKING TECHNICAL SUPPORT 1.800.908.0884
ELECTRICAL INSTALLATION
Low Voltage Supply Option
TIP:
As an alternative to high voltage, the operator can be power by 24VAC. It is recommended to use Vikings Modular Power Box ( part # VNXMPB) as the source.
!
Caution:
Always turn off power breakers when working with high voltage. DO NOT connect the “Power Harness” to the Control Board until the electrical installation is complete and ready for verification.
Install the “Modular Power Box” at the nearest high voltage source (115V or 230V single phase AC) and connect to the operator Power Harness. Follow local codes or guidelines.
MAXIMUM DISTANCE:
500 ft. with 10 AWG wire
Solar Supply Option
Vikings Solar Package (
part # VA-SOCHP) is an efficient and effective solution to powering the operator with solar energy. (See page 46 for package details)
!
Tip:
Solar efficiency can be increased by activating the “Pre-Warning”
A
will then provide power to all nonessential controls beginning 3 seconds prior to gate movement and while the gate is moving. (page 25)
A
B
Connect the two panels in series.
Connect the batteries in series.
Disconnect the operators power harness and use the
Solar Harness.
!
IMPORTANT:
The number of cycles achieved daily is dependent on many factors, including local solar radiation data and power consumption of the motor and accessories. It is very important that you consider this when using solar power.
VIKING TECHNICAL SUPPORT 1.800.908.0884
1 9
LIMITS SETUP
STEP 1
Connect the “Limit Switch Harness” to the Control Board.
a. “OPEN RIGHT” Connector if the gate opens Right.
b. “OPEN LEFT” Connector if the gate opens Left.
1
1a
1b
STEP 2
At the “Limit Cam & Holder” assembly:
a. Loosen screws on both of the “Limit
Switch Cams”.
b. With the Articulating Arm and “Clutch” installed, insure that the “Clutch Guide
Pin” is seated into one of the four holes on the “Cam Holder”.
c. Move the gate manually to the desired closed limit position and adjust the nearest Limit Switch Cam to actuate the corresponding limit switch.
d. Slight tighten the Limit Cam Screw.
e. Repeat Step 2c & 2d for the desired open limit position.
f. Run the 2 full cycles before confirming your limit settings. Adjust accordingly if required.
Tip:
Referring to Step 2b. The “Cam Holder” contains four (4) Guide Pin holes to allow for proper positioning, if required, due to an alternative operator orientation.
Gate OPENS to the LEFT
Left Limit Switch = Closed Limit
Right Limit Switch = Open Limit
Gate OPENS to the RIGHT
Left Limit Switch = Open Limit
Right Limit Switch = Closed Limit
2 0
VIKING TECHNICAL SUPPORT 1.800.908.0884
LIMITS SETUP
! IMPORTANT:
This gate operator uses mechanical limit switches. Therefore, the limits cannot be set electronically by the control board. The Limit Buttons on the control board have been rendered inactive.
!
TECHNICAL TIP:
Each Limit LED will illuminate solid when the corresponding limit switch is actuated. The LEDs will flash simultaneously while both limit switches are actuated at the same time. This display may indicate a problem with the limit switches or wires.
“Open Limit” LED indicates the gate is at the open limit.
“Close Limit” LED indicates the gate is at the close limit.
VIKING TECHNICAL SUPPORT 1.800.908.0884
2 1
MASTER/SLAVE SETUP
Two Wire Communication
!
IMPORTANT:
DO NOT run the Master/Slave communication cable in the same conduit or within 12” of 115 - 230v power supply cables.
!
Technical Tip:
DO NOT set the “Timer” and/or “Overlap” features on both operators
Control Boards. Only turn these features on at the Master Control Board.
CABLE REQUIREMENTS:
• 2 Conductor (wire)
• 18 AWG or better
• Shielded (overall foil)
• Drain Wire (non-insulated or bare wire)
2 2
Shielded Cable
Master Board
“MS1”
“MS2”
Condui t
Drain Wire
Slave Board
“MS1”
“MS2”
Conduit between
Master and Slave
VIKING TECHNICAL SUPPORT 1.800.908.0884
MASTER/SLAVE SETUP
Wireless Communication Options
!
Technical Tip:
DO NOT set the “Timer” and/or “Overlap” features on both operators
Control Boards. Only turn these features on at the Master Control Board.
REQUIRED ADD-ON:
Choose option A or B
A. Viking Konnect - Wireless Master/Slave Kit
PART# VA-KONNECT-MS
B. Viking Blue - Wireless Master/Slave Kit
PART# VA-BLUE-MSKT
Connect the Modules provided to the “V.K” plug & play connection of each operators
Control Board. It is not important which board the master or slave module is placed on.
VIKING TECHNICAL SUPPORT 1.800.908.0884
Green LEDs will be illuminated solid when communication is ON.
2 3
CONTROL BOARD SETUP
Initial Settings
“Timer”
Hold Open Timer
Automatically closes the gate after the selected amount of time from 1-60 seconds.
Turning the dial between “0” and “OFF” will disable this feature, requiring a close command to close the gate.
“Overlap”
Overlap Delay
For Master/Slave applications. The control board that has this feature turned on is the MASTER and will delay from 1-6 seconds. Slave will delay to close.
!
Do not turn this feature on at both control boards, only the Master.
2 4
“ODS”
Obstruction Detection Sensor
Sets the amount of force required to trip the inherent obstruction sensor.
See page 26 for more details about this feature.
“Speed”
Motor Speed
Increases or decreases the speed of gate travel.
VIKING TECHNICAL SUPPORT 1.800.908.0884
CONTROL BOARD SETUP
Initial Settings
NOTE:
Installing a shunt or jumper on the pins will activate the feature.
“Auto Open” - Power Failure Option
Opens the gate automatically during power failure. Resumes normal operation when power is restored.
“Last Open” - Power Failure Option
Opens the gate automatically when the battery backup voltage is critically low.
“Pre-Warning”
Initiates two options for an audio or visual warning 3 seconds prior to gate motion and will continue:
1. Until gate reaches closed limit:
“Magnetic Lock” terminals provide a contact between “COM” and “N.O.”.
2. Until gate reaches either limit:
“AUX. PWR” terminals provide 24VDC.
“Sync”
Used only in conjunction with the Viking Barrier gate operator model
B-12. Activating this feature allows for synchronized operation with the B-12 operator. See page 35.
“EXT”
Available for future developments.
!
IMPORTANT:
Regardless of the power failure options chosen, the gate can be moved manually with a relatively low amount of force by following the steps for “Manual
Release” as outlined at on page 11.
VIKING TECHNICAL SUPPORT 1.800.908.0884
2 5
2 6
CONTROL BOARD SETUP
Obstruction Sensor (Primary Entrapment Protection)
!
IMPORTANT:
The appropriate “ODS” setting is dependant upon the gate installation and construction. Set this feature accordingly. Additional Safety equipment should be used to reduce possible risk of injury or vehicle damage.
“ODS” Obstruction Detection Sensor
The Obstruction Sensor detects obstructions in the path of the traveling gate. The dial sets the amount of force required to activate the operators inherent obstruction detection.
Setting the dial to “0” will require the least amount of force to activate;
Setting the dial to “100” will require the maximum amount of force to activate.
UL325 standard requires an audio alarm to go off after two consecutive entrapment events sensed by the
Inherent Entrapment Protection of the
Gate Operator.
The audio alarm will sound for a period of 5 minutes or until a Stop command or the “Alarm Reset” switch has been actuated. (refer to page 12)
When the Obstruction Sensor detects an obstruction it will:
1. Stop the gate’s movement and reverse it momentarily.
2. Bring the gate to a resting position.
3. Disable the Hold Open Timer feature until the Gate Operator receives a new command.
If second obstruction is detected before the gate reaches either limit it will:
1. Stop the gate’s movement.
2. Disable the Gate Operator.
3. Sound the UL Alarm
4. A STOP command must be provided to disable the alarm and continue operation.
!
TECHNICAL TIP:
The Status LED for the
“ODS” will indicate the following when it has been triggered.
A. Solid: Obstruction.
Detected a sudden or abrupt increase in gate resistance.
B. Flashing: Overload.
Detected a more subtle, but sustained increase in gate resistance.
VIKING TECHNICAL SUPPORT 1.800.908.0884
CONTROL BOARD SETUP
Viking Heater
The operator has an integrated heater that is thermostatically controlled. Activate this feature when the operator is used in application temperatures down to -20°F (-29°C).
To set the heater to turn on at the Close Limit:
1. Use the “Diagnose” button to scroll through the LCD
Display to “HEATER CLS”
2. Press and hold the “Stop” button on the control board.
3. Press and release the “Diagnose” button to turn this feature ON and OFF.
HEATER
CLS ON
To set the heater to turn on at the Open Limit:
1. Use the “Diagnose” button to scroll through the LCD
Display to “HEATER OPN”
2. Perform steps 2-3 as described above.
HEATER
OPN ON
NOTE:
If the application requires the gate to be held open for any reason, set the HEATER
ON for both limit positions.
!
IMPORTANT:
A POSITIVE STOP
must be used on the gate at the limit position(s) the
HEATER has been set for.
Viking Lock Mode
Turning this feature ON will secure the gate at the closed position, preventing unauthorized manual entry.
Use the LCD Display to activate this feature.
1. Use the “Diagnose” button to scroll through the LCD menu to “LOCK MOD”
2. Press and hold the “Stop” button on the control board.
3. Press and release the “Diagnose” button to turn this feature ON and OFF.
LOCK MOD
ON
2 7
VIKING TECHNICAL SUPPORT 1.800.908.0884
(THIS PAGE LEFT BLANK INTENTIONALLY)
2 8
VIKING TECHNICAL SUPPORT 1.800.908.0884
ACCESSORY CONNECTIONS
Re-Open Photo Beam (vehicular Safety)
NOTE:
This type of photo-beam installation will stop then RE-OPEN the gate all the way to the open limit when the beam is obstructed. Intended for vehicular safety ONLY. For the purpose of pedestrian entrapment, see pages 10-11.
N.O.
COM
( - ) ( + )
Note regarding Photo Beam types:
Fail-Safe type - connect the “N.C.” terminal of the photo beam to the
“Re-Open” terminal on the control board.
Typically, these are the reflective type photo beams.
Fail -Secure type - connect the “N.O.” terminal of the photo beam to the
“Re-Open” terminal on the control board.
Typically, these are the transmitter/ receiver type photo beams.
Check for proper operation:
The “Re-Open” LED will illuminate solid while the beam is obstructed and remain off when the beam is unobstructed.
!
TECHNICAL TIP:
For more information regarding accessory connections to the control board and individual input terminal functions, refer to
“Appendix (A)”, pages 42-43.
VIKING TECHNICAL SUPPORT 1.800.908.0884
2 9
ACCESSORY CONNECTIONS
Radio Receiver (Typical)
!
IMPORTANT:
The Hold Open “Timer” setting (page 24) affects how the gate will respond to the radio receiver command.
COM
N.O.
(
-
)
(+)
The control board provides two modes of operation that a radio receiver can control the gate:
Open-Stop-Close
1. By having the radio receiver connected as illustrated and with the Hold Open
Timer OFF (see page 24):
Every command of the radio transmitter will control the gate as follows: a. First command opens the gate, b. Second command stops the gate and c. Third command closes the gate d. Any subsequent commands will continue in the same order to control the gate.
This type of configuration is not recommended for commercial installations.
Open Only
2. By having the radio receiver connected as illustrated and with the Hold Open
Timer ON (see page 24):
Each command of the radio transmitter is
ALWAYS AN OPEN COMMAND
to the gate.
For maximum reception range:
Locate the radio antenna to the top of the gate column.
!
TECHNICAL TIP:
For more information regarding accessory connections and terminal functions, refer to
“Appendix (A)” on pages 42-43.
See “Appendix (B)” on page 44 for connecting common radio receiver models.
3 0
VIKING TECHNICAL SUPPORT 1.800.908.0884
ACCESSORY CONNECTIONS
Anti-Tailgate, Open Commands & Guard Station
!
TECHNICAL TIP:
For more information regarding accessory connections and terminal functions, refer to “Appendix (A)” on pages 42-43.
Open Commands
“Exit”, “Fire” and “Strike” input terminals all provide an open command to the control board. Any device connected as shown will open the gate.
+
+ -
-
+
-
N.O.
COM
N.O.
COM
N.O.
COM
Guard Station
!
All three buttons must be a
Normally Open “N.O.” type of switch, and can share the same common “C” connection to “GND”.
“ATG” Anti-Tailgate
This input will stop the gate when the vehicle triggers the sensor, then closes the gate when the vehicle leaves the sensor, preventing unauthorized vehicles from entry.
+ -
COM
N.O.
3 1
VIKING TECHNICAL SUPPORT 1.800.908.0884
ACCESSORY CONNECTIONS
Viking Loop Rack
TIP:
This operator may be equipped with a pre-wired
Loop Rack that plug-in type loop detectors can be connected to. This provides a convenient alternative to the box type loop detectors that would need to be wired to the control board. Viking does not provide either type of loop detectors.
Loop Rack Wiring Harness: Part # VA-LRH
3 2
VIKING TECHNICAL SUPPORT 1.800.908.0884
ACCESSORY CONNECTIONS
Guidelines for Loop Installation
1. Prevent sharp corners in the geometry of the loop sensor.
2. Install the appropriate number of turns for your loop geometry based on the loop perimeter. Use Table C (below) as a guide.
3. Use XLP (cross-linked-polyethylene) type of wire. This wire reduces the effects of moisture and other environmental events in altering the functionality of the vehicular loop detector.
4. Twist the lead wire at least 6 turns per foot.
5. Use BACKER-ROD to minimize damage to the loop detector wire prior to using the sealant.
6. Place the loop detector wire and adjust the sensitivity of the vehicular loop detector unit in a way to minimize the effects of the gate over the loop detector wire.
!
IMPORTANT!
Some of the following parameters may affect the proper functionality of the vehicular loop detector.
Consult the manufacturer of the vehicular loop detector and/or loop wire.
• Gate size
• Number of turns in the loop sensor wire
• Distance of the loop sensor wire to the gate at either at the open or close position
Table C - Recommended Number of Turns
Perimeter (ft.) Number of Turns
50-100 2
Outside
Reopen
Loop
A
VIKING TECHNICAL SUPPORT 1.800.908.0884
A
5'
Center
Loop
5'
Dimension “A” - 5’ for Single Gate
6’ for Dual Gate
5' 5'
Inside
Reopen
Loop
Make Even with Open Gate
Exit
Loop
Gate in Open Position
3 3
3 4
ACCESSORY CONNECTIONS
Magnetic Lock, Lock Solenoid
NOTE:
Viking Access Systems does not provide external gate lock devices. These items can be purchased from your dealer or distributor.
Magnetic Lock
( + )
( + )
Power for the Locks:
Do not use the 24VDC power supplied by the control board. An external power supply, or plug-in transformer, must be used for the magnetic lock or lock solenoid. Plug the transformer into the
“120VAC” receptacle provided at the operators Power Box. This will prevent rapid drainage of the battery in the event of power failure.
The control boards “Magnetic Lock” relay is rated for 10A-250VAC.
!
TECHNICAL TIP:
The Magnetic Lock Relay
LED will indicate status of the on-board relay even if a lock is not connected to the control board. Refer to page 36.
Lock Solenoid
( + )
( + )
VIKING TECHNICAL SUPPORT 1.800.908.0884
SYNCHRONIZATION WITH B-12
Barrier Arm (B-12) Synchronization Option
NOTE:
The Control Board provides a convenient solution for applications that require synchronized operation with the Viking Barrier Arm Operator model B-12.
This type of application opens and closes in the following pattern:
1. Open Command is provided only to the Viking B-12 Barrier Arm Operator.
2. The Barrier Arm will delay to open until this Gate Operator reaches its Open Limit.
3. The Gate Operator will delay to close until the Barrier Arm reaches its Close Limit.
STEP 1
(Figure A & B)
Connect the Gate Operator to the Viking
B-12 Barrier Arm Operator as illustrated.
STEP 3
(Figure B)
On the Gate Operator Control Board, activate Sync Mode by placing a jumper on to the pin headers labeled “SYNC”.
Figure A
1
STEP 2
(Figure A)
At the B-12 Barrier Arm Operator, connect the primary device that will be used as the OPEN input.
Figure B
2
STEP 4
(Figure C & D)
Connect Viking B-12 Barrier Arm
Operator to the Gate Operator as illustrated.
Figure C
Figure D
4
VIKING TECHNICAL SUPPORT 1.800.908.0884
3
3 5
TROUBLESHOOTING
LED References
In addition to the LCD Display, the control board LEDs monitor the various circuits of the control board. Use the table below to identify the corresponding “TS Ref#” and refer to page 38-41 for further troubleshooting.
3 6
# LED
1 “Magnetic
Lock Relay”
Status
OFF
SOLID
2 “Check Motor” OFF
SOLID
3 “Battery Low” OFF
SOLID
Meaning
At Closed Limit and Magnetic Lock Relay state is closed across “COM” &
“N.C.”. (pg 34). Gate should be at the Close Limit.
Not at Closed Limit and Magnetic Lock Relay state is closed across “COM” &
“N.O.”. (pg 34). Gate should not be at the Close Limit
Normal Condition.
Page 41
TS Ref#(s)
The control board is sending power to the motor but the circuit is open.
7, 8
Normal Condition.
Batteries are low. Check power supply to the operator. (pg 18-19).
FLASHING Batteries critically low. Check power supply to the operator. (pg 18-19).
1, 2
1, 2
4 “POWER” SOLID Normal Condition.
FLASHING Operator is running on batteries only (pg 18-19).
OFF No power to control board.
1, 2
1, 2, 4, 5
5 “Radio” OFF Normal Condition.
SOLID
6 “UL”
7 “Re-Open”
8 “ATG”
OFF
SOLID
OFF
SOLID
OFF
SOLID
Control Board is receiving an input from a device connected to the
Radio terminal (pg 30, 42).
Normal Condition.
Control Board is receiving an input from a device connected to the UL terminal (pg 10-11, 42).
Normal Condition.
Control Board is receiving an input from a device connected to the Re-
Open terminal (pg 29, 32, 42).
Normal Condition.
Control Board is receiving an input from a device connected to the ATG terminal (pg 31, 42).
9, 10
9, 10, 16,
22
9, 10
9, 10
VIKING TECHNICAL SUPPORT 1.800.908.0884
TROUBLESHOOTING
LED References
Use the table below to identify the corresponding “TS Ref#” and refer to page 38-41 for further troubleshooting.
Pg 41
# LED Status Meaning TS Ref#(s)
9 “C Loop” OFF Normal Condition.
10 “Open”
11 “STOP”
12 “Close”
13 “Siren”
14 “Aux. Pwr”
SOLID
OFF
Control Board is receiving an input from a device connected to the
C Loop terminal (pg 32, 42).
Normal Condition.
SOLID
OFF
Control board is receiving an input from a device connected to any of the following input terminals: Exit, Fire, Strike or Open (pg 31, 42).
Normal Condition.
SOLID Control Board is receiving an input from a device connected to the
Stop terminal (pg 31, 42).
FLASHING There is a problem with the required monitored sensor(s) connected to the “UL” input terminal (pg 10-11)
OFF Normal Condition.
SOLID Control Board is receiving an input from a device connected to the
Close terminal (pg 31, 42).
Normal Condition.
OFF
SOLID Second consecutive obstruction has been detected. (pg 26).
FLASHING Batteries are critically low.
OFF
SOLID
No voltage output on these terminals at the moment.
There is 24VDC output on these terminals at the moment.
9, 10
9, 10
9, 10
16, 22
9, 10
11, 13, 1, 2
1, 2
15 “Diagnose”
16 “Close Limit”
OFF Normal Condition.
FLASHING Errors have been detected; Check LCD Display for ERR messages (pg 40).
OFF
SOLID
Gate is not at the close limit position.
Gate is at the close limit position.
FLASHING Indicates a problem with the limit switches or wires. (pg 20-21).
OFF Gate is not at the open limit position.
6
17 “Open Limit”
18 “ODS”
19 “Timer”
20 “AC VOLTAGE INPUT”
SOLID Gate is at the open limit position.
FLASHING Indicates a problem with the limit switches or wires. (pg 20-21).
6
OFF
SOLID
Normal Condition.
Obstruction has been detected. (pg 26).
FLASHING Overload has been detected. (pg 26).
OFF The close timer is turned OFF or gate is not at the open limit if the timer is turned ON. (pg 24).
SOLID Gate is at Open Limit, Timer is turned ON and counting down to close. (pg
24).
FLASHING Gate is at Open Limit, Timer is turned ON but is not timing out due to a conflicting command. (pg 24).
SOLID Normal Condition.
11, 13, 1, 2
11, 13, 1, 2
9, 10
OFF
21
“PROTECTION WORKING”
SOLID
Incoming power to Power Supply Panel Assembly is not sufficient.(pg 18).
Normal Condition.
1
OFF
22
“AC VOLTAGE OUTPUT”
SOLID
23 “AC POWER”
OFF
SOLID
OFF
EMI Board is damaged and circuit is not protected . Replace EMI Board.
Normal Condition.
There is no output voltage from the Power Supply Panel Assembly.
Normal Condition for High Voltage installations.
High Voltage is not supplied to the Modular Power Box (pg 18).
2
1
VIKING TECHNICAL SUPPORT 1.800.908.0884
3 7
TROUBLESHOOTING
LCD Display References
The control board is equipped with a LCD Display that provides operator information, current conditions, settings, diagnostics and error messages. Use the table below to identify the corresponding “TS Ref#” and refer to page 41 for further troubleshooting.
1. Error Messages will be displayed first.
2. The ”Diagnose” LED will flash consecutively indicating how many Error Messages are available.
3. Press the Diagnose button to manually scroll through all of the Messages.
LCD MSG
Meaning
VIKING
ACCESS
Welcome Message
MODEL
R6
Indicates the Model of the unit
System Status Messages
Page 41
TS Ref #s
GATE IS
IDLE
GATE IS
OPENING
GATE IS
CLOSING
GATE IS
OPENED
GATE IS
CLOSED
STOP BY
OBSTRUCT
STOP BY
OVERLOAD
OVERLAP
TIMING
HOLDING
__ SEC
UL LEARN
SENSOR _
3 8
Gate is stopped between limits
Gate is opening
Gate is closing
Gate is at the limit open position
Gate is at the limit close position
Gate stopped due to an obstruction sensor event
Gate stopped due to an overload of the gate system
Gate is waiting for the overlap time
Gate is at the limit open position and timing to close - The display shows the actual time left before closing
Indicates the number of connected Secondary Entrapment Protection
Sensors that are being monitored through the UL input terminal. (pg 11)
11, 12,
13
11, 12
VIKING TECHNICAL SUPPORT 1.800.908.0884
TROUBLESHOOTING
LCD Display References
Speed
__%
OVERLAP
_._ SEC
ODS SENS
___%
TIMER
__ SEC
HEATER
__ OFF
HEATER
__ ON
LOCK MOD
OFF
LOCK MOD
ON
LCD MSG
Meaning
Multi Meter Displays
MOT AMP
__._ A
MOT VOLT
__._ VDC
AC VOLT
__._ VAC
CHARGE
__._ VDC
BAT VOLT
__._ VDC
This is the motor current amperage during operation
This is the actual motor voltage during operation
This is the actual low voltage AC to the Control Board from the transformer
Indicates the charging voltage to the batteries, if the Battery Switch is in the OFF position.
Indicates battery voltage, if the AC power is discontinued to the Control
Board.
Board Settings Messages
Shows the percentage of speed set by the Speed adjustment on the control board. (pg 24)
Shows the number of seconds set by the Overlap Adjustment on the control board. This feature is not available on slide gate operator models
Shows the force setting selected to trip the obstruction sensor. (pg 26)
Shows the amount time set or remaining to hold the gate at the Open Limit position, before the gate starts to close. (pg 24)
The Integrated Heater is disabled for the open
“OPN”
and/or close
“CLS”
limits (pg 27)
The Integrated Heater has been enabled to turn on at the open
“OPN”
and/ or close
“CLS”
limits (pg 27)
“*”
will be displayed while it is heating
The Lock Mode feature is turned OFF (pg 27)
The Lock Mode feature is turned ON (pg 27)
Page 41
TS Ref #s
3 9
VIKING TECHNICAL SUPPORT 1.800.908.0884
TROUBLESHOOTING
LCD Display References
LCD MSG
Meaning
Error Messages
ERR FUSE
15 AMP
ERR EMI
NO EMI
ERR EMI
NO FUSE
ERR EMI
NO AC
ERR EMI
Unknown
ERR EMI
PROTECT
ERR UL
SENSOR
ERR AC
LOW
ERR AC
HIGH
ERR AC
NO AC
ERR CHRG
HIGH
ERR CHRG
CHECK 4A
ERR BAT
LOW
Indicates that the 24VAC supply to the VFlex Board is too low from the
115/230 power supply.
Indicates that the 24VAC supply to the VFlex Board is too high from the
115/230 power supply.
Indicates that there is no 24VAC supply detected to the VFlex Board from the 115/230 power supply.
Potential problem with the charging voltage from the control board.
a) 4 Amp Fuse is blown, or; b) There is a problem with the batteries or the control board.
18, ?
The battery is low.
15 Amp motor fuse is blown on the Master or Single Control Board.
No EMI board detected.
4 Amp main fuse is blown on Power Supply Panel Assembly.
There is no AC voltage detected from the EMI Board.
Page 37
TS Ref #s
1, 2, 4,
20
1, 2, 3,
4
There is a problem with the communication between the EMI Board and the
VFlex Board.
21
Lightning strike protection for the EMI Board (behind the Power Supply
Panel Assembly) needs to be replaced.
There is a problem with the required monitored sensor(s) connected to the “UL” input terminal (pg 10-11).
1, 3, 20
1, 3, 20
1, ?
7, 11, 12
15
2
20
?
22
4 0
VIKING TECHNICAL SUPPORT 1.800.908.0884
TROUBLESHOOTING
Solutions
Begin the troubleshooting process by referring to the error messages on the LCD
Display and/or the Status LEDs on the control board. Use pages 36-40 to identify the Troubleshooting Reference # (TS Ref#) then reference the table below.
TS Ref# CHECK
1 Check that the high voltage power supplied to “EMI Board” is within range.
100V-120V or 200V-240V.
Page Ref#
2 Remove and check EMI Fuse for continuity.
pg 18 pg 18
3 Check that the “Voltage Selector”, on the EMI Board, is set according to the high voltage power supply. 115VAC or 230VAC.
pg 18
4 Check that the “AC POWER” switch is turned ON.
pg 18, 36-
37
5 Check that the Power Harness is connected to the control board.
pg 4, 18
6 Check that the limit circuits are Normally Closed (N.C.). Check the limit switch.
pg 20-21
7 Check Motor Fuse on the control board.
8 Check that the operator is not in Manual Release mode.
pg 4 pg 3, 11
9 Check the Status LEDs and LCD Display to determine if the control board is receiving an input from any external devices or if the “ODS” has been triggered. pg 24, 26,
36-38
10 Remove the external devices from the control board to determine if the control board is responding to an input or problem with the external device or wiring.
11 Check the “ODS” setting on the control board.
pg 29-32,
36-37 pg 8, 12,
26
12 Check that the gate can be moved manually with low resistance throughout its full range of motion.
13 Check the limit position.
14 Not applicable to this model.
pg 8, 17 pg 20-21 pg 4
15 Check that the EMI cable is properly connected to the “EMI” connection at the
VFlex control board and at the EMI Board.
16 Check the LCD Display for Error Messages.
17 Not applicable to this model.
18 Check 4 Amp fuse on the control board.
19 Manually adjust any setting on the Control Board to clear all wireless override settings.
pg 4 pg 40 pg 4
20 Check for 24VAC out from the Toroidal Transformer and Power Harness.
pg 3, 18
21 Check the EMI Cable and contacts between the EMI Board and the VFlex Board. pg 2, 4
22 Check the secondary entrapment protection sensors connected to “UL” terminal.pg 10-11
?
The Control Board or EMI board may be damaged. Call Viking Technical Support for further assistance.
4 1
VIKING TECHNICAL SUPPORT 1.800.908.0884
Appendix (A)
Access Control Connections
Power Connections
The control board provides a 24VDC output to power external devices and controls.
Alternatively, for devices that require a power supply other than 24VDC, the operators Power Box contains a convenient 120VAC receptacle to connect a plug-in transformer.
Terminals Connections and Input Functions:
“C”
“N.O.”
=
=
Common
Normally Open
+
”
–
”
“GND” --------------------- Relay Common --------------- “C”
If “Timer” OFF:
If “Timer” ON:
Open - Stop - Close
Open / Reopen if closing
If input is brief:
If input is longer:
Stops gate then Reverses 12 inches
Stops gate, does not reverse
If stopped: No function
If closing: Stops then Opens gate
“N.O.”
Input is received:
Input is released:
Stops gate if closing
Closes gate to prevent tailgating
If not at open limit:
If at open limit:
No function
Prevents gate from Closing
If stopped:
If closing:
If traveling:
Opens gate
Stops then Opens gate
Stops gate
If stopped:
If traveling:
Closes gate
No function
!
TECHNICAL TIP:
Each input Terminal (i.e. Radio, Exit, Re-Open, UL) has a corresponding
Status LED that when illuminated indicates an input is currently being provided to the terminal and the gate is responding accordingly. (See pages 36-37 LED References)
4 2
VIKING TECHNICAL SUPPORT 1.800.908.0884
APPENDIX (A)
Relays In General
NOTE:
Viking Access Systems does not provide the external safety devices and access controls. These items can be purchases from your dealer or distributor.
In General
In regards to the Viking control board, all external safety devices and access controls contain, and are, simple relays that provide an input to the Viking control board when the device is activated.
When these devices are activated, their internal relays create a contact, or short, between the “C” and “N.O.” terminals. This contact is what provides the command to the Viking control board.
!
TECHNICAL TIP:
Viking uses the
Normally Open “N.O.” contact from the device, excluding “fail-safe” type photo beams. In such instances, the Normally
Closed “N.C.” will be used instead.
+28V
GND
+
COM
—
N.O.
N.C.
GND
EXIT
Not
Used
Glossary of Terms
1. Terminal: Wire Connections.
2. Input Terminal: On the Viking control board, the terminal which is labeled for a specific command (Re-
Open, Exit, Radio, etc.). The N.O. contact from the access control device is to be connected to the Input
Terminal.
3. Terminal Block: On the Viking control board, a removable block containing multiple terminals.
4. Relay: The component of an access control or safety device that provides an input or command to the Viking control board.
5. “C” Relay Common Terminal: This is the relay terminal that makes contact
(a short) to the N.O. terminal when the device is activated. Always wire this
relay terminal to any “GND” terminal at the control board.
6. “N.O.” Relay Normally Open
Terminal: The relay terminal that has an open contact to “C” while the relay is not activated, and a closed contact when the relay is activated. Almost
always wire this relay terminal to an
“Input Terminal” at the control board,
7. “N.C.” Relay Normally Closed
Terminal: The relay terminal that has a closed contact to “C” while the relay is not activated, and an open contact when the relay is activated. This
terminal is rarely used.
8. Relay Coil: Contains the terminals that provide power at the relay.
9. “
+
” Relay Positive Terminal: The positive power pole for the relay coil.
Always wire this relay terminal to any
“+28v” terminal at the control board.
10. “
–
” Relay Negative Terminal: The negative power pole for the relay coil.
Always wire this relay terminal to any
“GND” terminal at the control board.
4 3
VIKING TECHNICAL SUPPORT 1.800.908.0884
4 4
VIKING TECHNICAL SUPPORT 1.800.908.0884
APPENDIX (C)
Solar Applications
NOTE:
Viking recommends Solar Package (
part # VA-SOCHP) for most general solar applications. Alternatively, individual and third party solar components can be used.
The following are minimum system requirements and installation information.
Panels
• Voltage 24V
• Wattage 80W (minimum)
Cut the wires coming from the toroidal transformer.
Connect the solar panel cables to the power harness as shown.
Batteries & Fuse
Voltage 24V
Amp Hour 35Ah (minimum)
Replace the operators batteries with
35Ah or greater.
!
IMPORTANT:
The chart provided can be used as a guide for the number of cycles the gate will operate per day. The chart is for a single gate operator with just: a. One Radio Receiver b. One low voltage, low current loop detector c. One low voltage, low current photo beam
If more specific information is needed please consult with Viking Access Systems.
For more information regarding solar energy refer to www.nrel.gov/solar
VIKING TECHNICAL SUPPORT 1.800.908.0884
4 5
4 6
VIKING EXPANSION PRODUCTS
VIKING KONNECT Master/Slave Kit
Secure and reliable
Master/Slave communication using Viking’s Konnect technology. Paired with the Viking App, each module also doubles as a diagnostic tool.
Part# VA-KONNECT-MS
***Q-7, B-12 & ECU Operators require (2) Antenna Extension Cables (part# VA-RPSMA)***
VIKING KONNECT Diagnostic Tool
On-site remote access to the operator from the convenience of a compatible hand held device. With the Viking App, this tool becomes a wireless extension of the control board allowing you to view and change settings, review diagnostic information, operate the gate for testing and update the control boards firmware.
Part# VA-KONNECT-D
***Q-7, B-12 & ECU Operators require ( 1) Antenna Extension Cable (part# VA-RPSMA)***
VIKING MONITOR
Off-site access to operator diagnostics and perform firmware updates from just about anywhere with cellular service. With the Viking App, this tool allows you to monitor and label multiple operators by site and location for quick reference. Provides error notifications, operator status, settings and diagnostic information.
Part# VA-MONITOR
***Q-7, B-12 & ECU Operators require ( 1) Antenna Extension Cable (part# VA-RPSMA)***
VIKING APP
Mobile device user interface application for Viking
Konnect and Viking Monitor. Available for iOS, Android and Windows operating systems. Free for download from your mobile device application store or www.vikingaccess.com
VIKING AC SURGE PRO
Adds another layer of protection to the high voltage power supply of your gate operator. Connecting the AC
Surge Pro in parallel to the EMI Board, provides a dual layer of protection from surges up to 20,000 Volts / 10,000 Amps.
Part# VA-SURGEPROAC
VIKING SOLAR KIT
The components included in this package are intended to provide sufficient power for general applications.
Part# VA-SOCHP
This Kit includes the following components:
(2) 12V 40W Solar Panels
(2) 12V 35Ah batteries
(1) Solar Charger
Part# VA-SO40W
(wired in series = 24V 80W)
Part# DUBA35
(wired in series = 24V 35Ah)
Part# SOCHR10
Part# SOHAR
(1) Solar Power Harness
!
NOTE:
The number of cycles achieved from this kit are dependent upon the following and may require increased panel and battery capacities:
• Power consumption of all accessories being used
• Average solar radiation of geographic location
VIKING TECHNICAL SUPPORT 1.800.908.0884
OUR CONTINUOUS COMMITMENT TO EXCELLENCE
Viking Access Systems is continuously working hard to identify and design products that will appeal to the industry and its needs. As technology continues to advance, we have developed a completely effi cient and intelligent line of gate operators to meet the changing demands. These machines offer: full UL325 and UL991 compliance, soft-start and soft-stop, intelligent obstruction sensors, continuous operation (100% duty cycle) and extreme power effi ciency. Innovative features include: adaptive and self-learning algorithms, redundancy design in both hardware and software to ensure operation and functionality, protection from lightning, short circuit and power surges, and our exclusive helical gearing offering the highest effi ciency rating in the industry. Our entire product line is continually modifi ed and improved based on the latest technology and our customer’s valuable feedback. The results are products that offer accuracy, effi ciency, reliability and performance, all in sleek, high-tech designs.
We pledge to continue establishing ourself as the leader in high quality, innovative gate operators by developing “Next Level” technology. We are committed to providing safety and convenience with innovative solutions for every security gate need.
STANDARD FEATURES
AND OPERATOR SPECIFICATIONS
• UL Listed; UL325 and UL991
• ETL Listed; UL325 and UL991
• Mechanical gate release handle
• Elegant design, appealing to any architectural project
• Plated and powder coated steel chassis
• Opening up to 120°
• 100% duty cycle
• 400 cycles of operation on backup battery
(600 lb. gate and 12’ length)
• Intelligent speed control with smooth start and stop, self-adjust system
• Anti-Tailgate and Operation Pre-Warning features
• On-Board LCD Display provides diagnostics, operator status, settings and real-time volt and amp readings
• Intelligent obstruction detection with adjustable sensitivity
• Built-in climate control for cold weather applications
• Built-in protection against lightning strikes or similar electrical surges
• Regulated power supply for your external accessories
• Inherent overload protection; redundancy design using multiple types of protection
• Modular connectors for easy access control and accessory installation
• Solar panel and low voltage wiring compatibility
• LED indicators display gate and operator status for easy troubleshooting
• Adjustable travel speed
INSTALLATION DATE:
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
COMPANY / INSTALLER:
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
CONTACT:
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
SERIAL NUMBER(S):
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
A L L I N S TA L L AT I O N , M A I N T E N A N C E A N D R E PA I R W O R K M U S T B E
D O C U M E N T E D A N D M A D E AVA I L A B L E T O T H E U S E R .
V I K I N G ACC E S S S YS T E M S
631 Wald Irvine, CA 92618
Phone 800.908.0884
Fax 949.753.1640
www.vikingaccess.com
advertisement
Key Features
- Handles gates up to 700 lbs.
- 14 ft. gate length capacity
- Efficient drivetrain
- Built-in battery backup
- Soft start/soft stop
- Adaptive algorithm