Genano 310 Operating

Genano 310 Operating

Genano 310 is an air purifier device based on Genano’s unique MFI™ system. It helps in improving the indoor climate by removing viruses, bacteria, mold spores, animal dander, and traffic originated soot. The MFI™ system is equipped with a gas absorber for the removal of harmful gases and ozone. It has a self-cleaning feature and requires only regular filling of Genano washing fluid + water and to regularly empty the dirty flush water basin.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Manual
Genano 310 Operating | Manualzz
GENANO® AIR PURIFICATION TECHNOLOGY
GENANO 310 AIR PURIFICATION DEVICE
OPERATING INSTRUCTION
This manual is for the Genano 310 log. Version.
GENANO LTD
Kimmeltie 3
FI- 02110 Espoo
FINLAND
Tel + 358 (0) 9 –7743 870
Fax + 358 (0) 9 –7533 130
www.genano.fi
[email protected]
GENANO LTD
TT /JSan
GENANO ®TECHNOLOGY
GENANO 310 OPERATING INSTRUCTION
G310 LOG_ UM_ENG V2.3
Page 2
TABLE OF CONTENTS
TABLE OF CONTENTS
2
GENANO 310 PURIFICATION DEVICE FOR INDOOR CLIMATE
3
IMPORTANT SAFETY INSTRUCTIONS
CONTENTS
TECHNICAL FEATURES
3
4
4
INSTALLATION AND OPERATING INSTRUCTIONS
5
PARTS AND INDICATIONS OF SYMBOLS
BEFORE USE
INSTALLATION
WASHING LIQUID
POSITIONING
WALL MOUNTING
OPERATION OF THE DEVICE
NORMAL OPERATION
RUNNING OUT OF WASHING LIQUID
ERROR/SERVICE
RESETTING PROGRAM SETTINGS
POWER WASH
GAS ABSORPTION PLATE
5
5
6
6
6
7
7
7
8
9
9
9
10
WARRANTY
12
IMPORTANT SAFETY INSTRUCTIONS
13
TROUBLESHOOTING GUIDE
14
READ OWNERS MANUAL CAREFULLY!
Genano Ltd.
Kimmeltie 3
FIN-02110 ESPOO
Tel. +358 (9) 7743 870
Fax. +358 (9) 7743 8711
email: [email protected]
www.genano.fi
GENANO LTD
TT /JSan
GENANO ®TECHNOLOGY
GENANO 310 OPERATING INSTRUCTION
G310 LOG_ UM_ENG V2.3
Page 3
GENANO 310 PURIFICATION DEVICE FOR INDOOR CLIMATE
The GENANO 310 is an air purification device based on Genano’s unique MFI™ system.
Genano’s patented MFI removes even the smallest impurities from indoor air. These impurities
can consist of viruses, bacteria, mould spores, animal dander as well as traffic originated soot.
These ultra fine-particles (UFP) have recently been recognized to constitute a health hazard.
UFP’s easily penetrate into bronchial regions and can pass directly into the blood circulatory system. In many cases, fine-particles are the origin for cardiac and vascular discomfort, cancer and
even premature death.
The MFI™ system is equipped with a gas absorber for the removal of harmful gases and ozone.
The continued use and maintenance of the 310 air purifier will ensure you a comfortable breathing
environment. The GENANO 310 is self-cleaning and requires only regular filling of Genano washing fluid + water and to regularly empty the dirty flush water basin. Clean the basin soon after the
washing if you want to ensure that there will not grow any unwanted growing material.
The GENANO 310 air purifier has been tested by independent certification organizations. These
experts have officially certified that the cleaning results exceed 98% for atmospheric particles and
microbs in the 0.003-10µm range.
IMPORTANT SAFETY INSTRUCTIONS
Read all instructions before using this appliance.
When using an electric air cleaning device, basic precautions should always be followed, including
the following:
DANGER
To reduce the risk of electric shock:
1. Do not reach for a plug of an air purifier device that has fallen into water. Disconnect power at
source then unplug immediately.
2. Do not use in close vicinity while bathing or in a shower.
3. Do not place in heavily moist atmosphere, water or other liquid.
4. Do not place or store an air purifier device where it can fall or be pulled over.
5. Unplug this air purifier device before moving or transporting it to another location.
6. When discarding material used in this air purifier device, follow instructions issued by local authorities for disposal. See enclosed sheet for instructions.
7. Ensure that wall socket is grounded.
8. Lock the bottom basin when G310 is operated near children or pets.
IMPORTANT ! To reduce the risk of electric shock, this equipment has a grounding type plug that has a third
(grounding) terminal. This plug is only allowed to connect into a grounding type power outlet. If there is no
grounded outlet installed, contact qualified personnel to install the proper outlet. Do not alter the plug in any
way.
WARNING ! Due to its mode of operation the electronic air purifier may occasionally emit
sparks. Never use the air purifier in a place where flammable gases or liquids or large amounts
of dust may combine with air to form an explosive mixture.
Genano Ltd.
Kimmeltie 3
FIN-02110 ESPOO
Tel. +358 (9) 7743 870
Fax. +358 (9) 7743 8711
email: [email protected]
www.genano.fi
GENANO LTD
TT /JSan
GENANO ®TECHNOLOGY
GENANO 310 OPERATING INSTRUCTION
CONTENTS
1 Bottle: Genano washing fluid (1 ltr)
G310 LOG_ UM_ENG V2.3
Page 4
1 Mixing/water can
*To make refilling the 310 as
easy as possible. Notice the
marks on the side for easy
measuring
OR
1 Bottle: Genonex anti-bacterial
washing fluid (5ltr)
*only use approved Genano washing fluid in any
of Genano’s machines
1 plastic basin container
1 GENANO 310 air purification unit
with mains power cable
*empty basin on a regular basis
and clean away any remaining
residue every month with a
towel or soft brush
*contains 1 gas absorber to handle gas emissions. Make sure
filter is changed annually
DO NOT SCRATCH BASIN
TECHNICAL FEATURES
Use:
Indoor air environment only
Dimensions:
450mm x 385mm x 1470mm
Weight, approx:
55kg
Chassis:
Aluminum, zinc coated steel
Capacity:
100-250m3/h
Operating voltage:
200-240V, 50/60Hz
Power consumption:
140W max
Cleaning range:
>0.001µm
Ambient temperature:
+5 - +60°C
Humidity level of air:
0 -95%
450mm
385 mm
Clean air
distributed
Positioning: stand vertically on an even base or wall
mount. Unit has bottom wheels for portability.
1470 mm
Always maintain vertical position.
NEVER USE OR STORE HORIZONTALLY
*If machine is stored horizontally then flush out
all washing liquid with regular water
Washing: Automatically runs washing cycle once a
week. Always fill with GENANO washing fluid and water when the yellow “FILL WATER” light comes on.
Empty the flush water basin regularly.
Genano Ltd.
Kimmeltie 3
FIN-02110 ESPOO
Polluted air
sucked into
the air cleaner
Tel. +358 (9) 7743 870
Fax. +358 (9) 7743 8711
email: [email protected]
www.genano.fi
GENANO LTD
TT /JSan
GENANO ®TECHNOLOGY
GENANO 310 OPERATING INSTRUCTION
G310 LOG_ UM_ENG V2.3
Page 5
INSTALLATION AND OPERATING INSTRUCTIONS
PARTS AND INDICATIONS OF SYMBOLS
A. BOTTOM BASIN (basin for flush water / clean water container)
B. SIGNAL LIGHTS
-
OPERATION
Green light
-
AUTOMATIC WASH/DRYING
Green light
-
CLOSE BASIN
Green light
OK
B)
-
ERROR/SERVICE
Red light
-
FILL WATER
Yellow light
C)
C. OPERATION SWITCHES
A)
-
MAIN SWITCH (ON/OFF)
-
POWER WASH
- FAN SETTINGS/CAPASITY
100m3/h to 250 m3/h
*Maximum air volume
output may vary depending
on air purification needs and
version type
BEFORE USE
This product should always be transported in a vertical position. If transported horizontally let device dry 8 hours in vertical position before switching on.
Standing vertically on a stable, even base or wall mount.
ATTENTION: NEVER USE HORIZONTALLY.
Genano Ltd.
Kimmeltie 3
FIN-02110 ESPOO
Tel. +358 (9) 7743 870
Fax. +358 (9) 7743 8711
email: [email protected]
www.genano.fi
GENANO LTD
TT /JSan
GENANO ®TECHNOLOGY
GENANO 310 OPERATING INSTRUCTION
G310 LOG_ UM_ENG V2.3
Page 6
INSTALLATION
1. It is recommended to fill the water container before switching the
device ON.
D
2. Open the bottom basin by unlocking (d) and using the attached
handle (e).
E
3. Fill the water container (g) with water and washing fluid mixture
(See instructions below) (max. about 1,5 liters)
DO NOT CONNECT VOLTAGES OTHER THAN THE FACTORY LABELED REQUIREMENT.
4. Make sure that the main switch is in the OFF position (see above).
Plug the main power cable into GENANO 310 before you plug in
the main cable into a grounded power socket.
5. Push the main switch into ON - position.
G
LOCK THE BOTTOM BASIN WHEN OPERATED NEAR
CHILDREN OR PETS
WASHING LIQUID
Genonex is premixed so just pour into watering container and pour in container (g)
Take 1,5 liters of distilled water and 1 dcl of Genano MFI-washing fluid and mix in
the watering can provided
POSITIONING
When position your unit please try to observe the following:
Position the unit where the people are working or staying for maximum effect (preferably in the
center of the area).
Do not treat unit as furniture and place in a corner for aesthetics or behind solid abject for cover.
The closer the unit is to the people the better results they will feel!!
Take care of normal ventilation. Do not position G310 in rooms where is no ventilation.
Be sure to position away from air intake vents so clean air isn’t drawn immediately into the
air ducts.
Genano Ltd.
Kimmeltie 3
FIN-02110 ESPOO
Tel. +358 (9) 7743 870
Fax. +358 (9) 7743 8711
email: [email protected]
www.genano.fi
GENANO LTD
TT /JSan
GENANO ®TECHNOLOGY
GENANO 310 OPERATING INSTRUCTION
G310 LOG_ UM_ENG V2.3
Page 7
WARNING ! Due to its mode of operation the electronic air purifier may occasionally emit sparks.
Never use the air purifier in a place where flammable gases or liquids or large amounts of dust may
combine with air to form an explosive mixture.
WALL MOUNTING
It is possible to mount the GENANO 310 unit on the wall using brackets provided by Genano.
Simply fasten the mounts to a wall capable of supporting 70kg by placing both brackets on the wall
vertical to each other and 800mm apart from the metal mount (picture 1).
Then simply slide the unit onto the wall mounts taking care that the metal tab slides into the holders on the back of the 310 unit (picture 2)
Picture 1. Placing the mounting
brackets
GENANO 310 Back panel
Picture 2.
Wall
800mm
Place unit by sliding wall
mount into metal holder
on back of unit
Holder
Fastener
Wall
mount
OPERATION OF THE DEVICE
NORMAL OPERATION
Genano 310 is cleaning air when OK-light is illuminated.
The device efficiently collects atmospheric particles on the collection surfaces. Washing of
the collection surfaces takes place automatically once a week. Important! It is recommended to let the unit be continuously ON to ensure the weekly washing.
During the flushing of the collection surface the green “WASH” light is on. After the flushing
cycle has ended the GENANO310 starts its drying period. During the drying cycle the 310 is
silent and the green “WASH” light on.
Do not open the door immediately after the wash cycle. Allow time for the washing liquid
to drain into the basin.
Genano Ltd.
Kimmeltie 3
FIN-02110 ESPOO
Tel. +358 (9) 7743 870
Fax. +358 (9) 7743 8711
email: [email protected]
www.genano.fi
GENANO LTD
TT /JSan
GENANO ®TECHNOLOGY
GENANO 310 OPERATING INSTRUCTION
G310 LOG_ UM_ENG V2.3
Page 8
The washing cycle lasts about 5-10 seconds, the drying period can vary (1min – 8 hours)
*If the unit is very wet inside it could take longer to dry).
*If the machine does not restart after a few hours then call your service representative.
NOTE: It is normal that the “WASH” light is on after the device has completed flushing and
the device is totally quiet. The GENANO 310 continues its normal air cleaning operation
automatically when the drying period is over.
NOTE: Clean the basin after the washing operations if you want to ensure that there will not
remain any harmful material.
RUNNING OUT OF WASHING LIQUID
The device is unable to perform the automatic washing function, if the container has run
out of water*
The yellow “FILL WATER” light is on (See signal lights)
The 310 will continue its normal air cleaning operation even if one automatic wash cycle is
missed due to a lack of washing mixture. However, the device stops the air-cleaning operation if washing liquid/water is still not added after week to the wash water container.
Fill up the water container according to instructions given in the info sheet. Do not
switch the unit OFF.
The yellow “FILL WATER” light will be lit until the water container is filled.
The device turns ON only after the filling up of the water container with the washing mixture.
1. Add washing mixture to the water container according to the installation instructions
2. Empty and clean the flush water basin if necessary
3. Shut the bottom basin.
The device automatically starts the normal air cleaning operation after the bottom basin is
closed. The “FILL WATER” light turns off and green OK light illuminates again.
If the bottom basin is not closed during the operation, the green “CLOSE BASIN”
light illuminates and the air cleaning operation is turned off automatically.
The device automatically continues normal operation when the bottom basin is closed and
the “CLOSE BASIN” light turns off.
Genano Ltd.
Kimmeltie 3
FIN-02110 ESPOO
Tel. +358 (9) 7743 870
Fax. +358 (9) 7743 8711
email: [email protected]
www.genano.fi
GENANO LTD
TT /JSan
GENANO ®TECHNOLOGY
GENANO 310 OPERATING INSTRUCTION
G310 LOG_ UM_ENG V2.3
Page 9
ERROR/SERVICE
Record all steps taken when the service light comes on. Include recent events,
moves and what lights were on before the service light came on. This will help
your Genano service representative identify and solve the problem quicker.
If the normal operation is disturbed, the red “ERROR/SERVICE” light is continuously lit. If
the “ERROR/SERVICE” light is on then:
1. Check that there is water in the water container
2. Check that the basin door in closed
3. Perform power wash
If the “ERROR/SERVICE” light has still not gone out then reset unit (see instructions below).
If “ERROR/SERVICE” light is still on check the troubleshooting guide for a possible solution.
If no solution can be found then contact an authorised Genano service representative.
RESETTING PROGRAM SETTINGS
1. Switch the unit OFF and wait about 20 seconds.
2. Switch ON.
POWER WASH
The power wash function can be performed by using the power wash switch (check “c” operation switches on page 5). This operation is useful if the air cleaning operation is interrupted due to increased dirtiness of the collection surface. The flashing “ERROR/SERVICE”
light illustrates the device is extremely dirty.
It is recommended that the power wash be performed every 6 months even if no operational problems have occurred.
Perform the Power Wash as follows:
1. Empty the flush water basin and fill the wash water container before performing the
power wash.
2. Press the power wash switch and hold it down until the 310 machine starts the wash cycle (about 5 seconds)
The Power wash lasts about 5 seconds. Following the power wash the “AUTOMATIC
WASH/DRYING” light is on while the machine dries. The drying cycle can last a few
minutes or longer depending on how damp the machine is.
Do not open the door immediately after the wash cycle. Allow time for the washing
liquid to drain into the basin.
3. Once the drying cycle is complete the unit will resume normal operation
Genano Ltd.
Kimmeltie 3
FIN-02110 ESPOO
Tel. +358 (9) 7743 870
Fax. +358 (9) 7743 8711
email: [email protected]
www.genano.fi
GENANO LTD
TT /JSan
GENANO ®TECHNOLOGY
GENANO 310 OPERATING INSTRUCTION
G310 LOG_ UM_ENG V2.3
Page 10
NOTE: Clean the basin after the washing operations if you want to ensure that there will not
remain any harmful material.
GAS ABSORPTION PLATE
Besides particles, the Genano air cleaner can also remove gases. Using a gas absorption
plate, different kinds gases can be removed from the indoor air e.g. traffic originated sulphurand nitrogen oxides as well as ozone. The typical exchange period of the gas absorption
plate is 12 months.
Gas absorber replacement can only be performed by service personnel authorised by
Genano Ltd.
ATTENTION: DO NOT OPERATE THE GENANO 310 UNIT WITHOUT THE
GAS ABSORPTION PLATE
Gas Absorber Exchange dates
/
Date of purchase
/
/
/
/
/
/
Gas Absorber Exchange dates
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
Genano Ltd.
Kimmeltie 3
FIN-02110 ESPOO
Tel. +358 (9) 7743 870
Fax. +358 (9) 7743 8711
email: [email protected]
www.genano.fi
GENANO LTD
TT /JSan
GENANO ®TECHNOLOGY
GENANO 310 OPERATING INSTRUCTION
/
/
G310 LOG_ UM_ENG V2.3
Page 11
/
Genano Ltd.
Kimmeltie 3
FIN-02110 ESPOO
/
Tel. +358 (9) 7743 870
Fax. +358 (9) 7743 8711
email: [email protected]
www.genano.fi
GENANO LTD
TT /JSan
GENANO ®TECHNOLOGY
GENANO 310 OPERATING INSTRUCTION
G310 LOG_ UM_ENG V2.3
Page 12
WARRANTY
GENANO 310
MULTIFUNCTION-ION™, MFI™, ® and NANOBIO™ are Registered Trademarks™ for Genano
Limited Corporation products. All Rights Reserved.
FULL 12 MONTHS WARRANTY
Genano Ltd warrants each new MFI™ Air Cleaning Product, Model against defects in materials or
workmanship for a period of one year from the date of purchase, and agrees to repair or replace
any defective product without charge.
IMPORTANT: This warranty does not cover damage resulting from accident, misuse or abuse,
lack of reasonable care, the affixing of any attachment not provided with the product or loss of
parts or subjecting the product to any but the specified voltage. Use of unauthorized replacement
parts will void this warranty.
GENANO CORPORATION WILL NOT PAY FOR WARRANTY SERVICE PERFORMED BY A
NON-AUTHORIZED REPAIR SERVICE AND WILL NOT REIMBURSE THE CONSUMER FOR
DAMAGE RESULTING FROM WARRANTY SERVICE PERFORMED BY A NON-AUTHORIZED
REPAIR SERVICE. NO RESPONSIBILITY IS ASSUMED FOR ANY SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES.
In order to obtain warranty service, simply contact the nearest Authorized Genano Service Location. It is suggested that for your protection you return shipments of products by insured transport,
insurance prepaid. Damage occurring during shipment is not covered by this warranty.
NOTE: No other warranty, written or oral, is authorized by Genano Ltd Finland.
This warranty gives you specific legal rights, and you may also have other rights which vary from
country to country. Some countries do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion and limitations may not apply to you+.
1. Never operate this device if it has a damaged cord or plug, if it has been dropped or damaged.
Return the device to an Authorized Genano Service Location for examination and repair.
2. Keep the cord away from heated surfaces.
3. Never drop or insert any object into any opening.
4. Do not plug in this air cleaning device outdoors or operate where aerosol (spray) products are
being used or where oxygen is being administered.
5. Do not use this device with a damaged or broken part, as injury may occur.
6. Always attach plug to device first, then to outlet. Be certain that plug is inserted firmly into device. To disconnect, turn device off, then remove plug from outlet.
7. To prevent possible damage to the cord, do not wrap cord around the air cleaning device.
8. Never put air cleaning device in direct, hot sunlight or store in pouch at a temperature above
140°F (60°C).
Genano Ltd.
Kimmeltie 3
FIN-02110 ESPOO
Tel. +358 (9) 7743 870
Fax. +358 (9) 7743 8711
email: [email protected]
www.genano.fi
GENANO LTD
TT /JSan
GENANO ®TECHNOLOGY
GENANO 310 OPERATING INSTRUCTION
G310 LOG_ UM_ENG V2.3
Page 13
IMPORTANT SAFETY INSTRUCTIONS
Read all instructions before using this appliance.
When using an electric air purifier device, basic precautions should always be followed, including
the following:
DANGER
To reduce the risk of electric shock:
1. Do not reach for a plug of an air purifier device that has fallen into water. Disconnect power at
main source then unplug immediately.
2. Do not use in close vicinity while bathing or in a shower.
3. Do not place in heavily moist atmosphere, water or other liquid.
4. Do not place or store an air purifier device where it can fall or be pulled over.
5. Unplug this air purifier device before moving or transport to another location.
6. When discarding material used in this air purifier device, follow instructions issued by local authorities for disposal.
7. Ensure that wall socket is grounded.
8. Lock the bottom basin when G310 is operated near children or pets.
WARNING
To reduce the risk of burns, fire, electric shock, or injury to persons:
1. Supervision is necessary when operated near children or the disabled.
2. Use this air purifier device for its intended indoor use, only, as described in manual. Do not use
attachments not recommended by Genano Ltd.
3. Never use in an area with heavy wood dust or explosive chemicals.
READ OWNERS MANUAL CAREFULLY!
Manufactured for:
GENANO LIMITED (FINLAND)
Genano Ltd.
Kimmeltie 3
FIN-02110 ESPOO
Tel. +358 (9) 7743 870
Fax. +358 (9) 7743 8711
email: [email protected]
www.genano.fi
GENANO LTD
TT /JSan
GENANO ®TECHNOLOGY
GENANO 310 OPERATING INSTRUCTION
G310 LOG_ UM_ENG V2.3
Page 14
Troubleshooting guide
Warning! Repairs and maintenance work must be carried out by qualified personnel only.
SYMPTOM
The power does not turn on.
• Check connection to the mains.
• Check that power is switched on.
• Check the service door is not open.
CORRECTIVE ACTIONS
The green WASH-light is on when device is not washing.
• Wait until the drying period is over.
• If after a few hours the unit does not restart then reset the system
• If error continues after resetting contact an authorized repair service
Red SERVICE/ERROR-light is continuously on.
• Wait several hours.
• Execute Power-wash.
• Reset default program settings (Switch the unit OFF and wait about 20 seconds then restart).
• If error continues after resetting contact an authorized repair service.
Device is leaking water.
• It is possible that device leaks water if transported horizontally. Wait 8 hours before first use.
• Check that the flush water basin is in its place. Empty basin if necessary
• If leaking continues contact an authorized repair service.
Operating lights are not functioning.
• Check connection to the mains.
• Check that power is switched on.
• Reset program settings.
“Increase water” light is not working when the water tank is empty.
• Contact an authorized repair service.
Airflow through the device is poor or it smells of metallic gases.
• Turn device off and contact an authorized repair service.
Genano Ltd.
Kimmeltie 3
FIN-02110 ESPOO
Tel. +358 (9) 7743 870
Fax. +358 (9) 7743 8711
email: [email protected]
www.genano.fi

advertisement