New Build Pocket Guide

NEW BUILD

YOUR COMPLETE

SOLUTION.

IDEAL

BOILER

STELRAD

RADIATOR

CYLINDER SOLAR

PANEL

FREE DESIGN

STAGE SAP

(USUALLY £50)

DESIGN

SERVICE

364 DAYS

A YEAR

WWW.IDEALBOILERS.COM

02

WELCOME

TO FIRST

CLASS.

OUR AWARD WINNING BOILERS GO

THROUGH 200 QUALITY CHECKS BEFORE

THEY LEAVE THE FACTORY, AND ARE

AVAILABLE WITH A RANGE OF FLEXIBLE

WARRANTY OPTIONS. YOU CAN REST

ASSURED RELIABILITY IS GUARANTEED

WHEN YOU PARTNER WITH IDEAL.

WELCOME

TO FIRST

CLASS.

OUR AWARD WINNING BOILERS GO

THROUGH 200 QUALITY CHECKS BEFORE

THEY LEAVE THE FACTORY, AND ARE

AVAILABLE WITH A RANGE OF FLEXIBLE

WARRANTY OPTIONS. YOU CAN REST

ASSURED RELIABILITY IS GUARANTEED

WHEN YOU PARTNER WITH IDEAL.

CONTENTS.

04 THE IDEAL PRODUCT RANGE

06 LOGIC COMBI ESP

14 LOGIC CODE COMBI ES

22 LOGIC SYSTEM

30 LOGIC HEAT

38 BOILER CONTROLS

42 LPG CONVERSION KITS

44 FLUE SITING

46 FLUEING OPTIONS

71 CONTACT US

03

04

THE IDEAL PRODUCT RANGE.

Representing the next generation in heating design, the Logic range of boilers offers state-of-the-art technology in a practical, compact unit that fi ts easily into any standard kitchen cupboard.

Available in a range of outputs, the Logic range comes complete with a fl exible parts and labour warranty package.

THE IDEAL PRODUCT RANGE.

Representing the next generation in heating design, the Logic range of boilers offers state-of-the-art technology in a practical, compact unit that fi ts easily into any standard kitchen cupboard.

Available in a range of outputs, the Logic range comes complete with a fl exible parts and labour warranty package.

LOGIC COMBI ESP

A high effi ciency combination boiler with a competitive SAP effi ciency score, particularly benefi cial for small, social new build properties.

LOGIC CODE COMBI ES

A simple one box solution, capable of supporting up to level 4 of the code for sustainable homes with built in fl ue gas heat recovery.

LOGIC SYSTEM

A simple and reliable solution for a wide variety of sealed domestic systems.

LOGIC HEAT ONLY

Highly effi cient and easy to operate, thanks to straightforward controls featuring a clear digital display.

05

6

LOGIC COMBI ESP 24 30 35.

HIGH EFFICIENCY COMBINATION BOILERS.

Optimised for new build compliance following the SAP 2009/2012 design procedure, the Logic Combi ESP achieves improved SAP effi ciency scores and is particularly benefi cial for new build properties.

LOGIC COMBI ESP 24 30 35.

FEATURES.

COMPACT DIGITAL

DISPLAY

FROST

PROTECTION

FLUE

VARIANTS

LPG

CONVERSION*

NOx

CLASS 5

SPECIFICATION.

• Complete range of Logic combination boilers for new build developers

EASY TO INSTALL

• Compact cupboard fi t

• Achieves improved SAP and DER ratings • Fast fi x fl ues for standard combination boiler usage

• 75mm deep translucent condensate siphon

• Fully modulating operation to low outputs

• Automatic bypass

Wide range of additional fl ueing options

Low lift weight (32kg)

Easy access to PRV and AAV

Preformed copper tails

Pre-wired mains lead (2m)

• Universal condensate connection

• Stand off kit including piping available

RELIABLE

• Energy Saving Trust endorsed product

• Boiler frost protection

• Built-in, easy to use fi lling loop

Compatible with a range of additional controls inc. weather compensation

LPG conversion kit available for

30 kW boilers • Simple diverter valve design

• Two stage fl ame sensing for greater reliability

• Latest generation Honeywell gas valve

• ErP compliant

7

* Available with 30 kW model.

8

CLEARANCES AND DIMENSIONS.

DIMENSIONS IN MM

DIMENSIONS:

Height: 700mm

Width: 395mm

Depth: 278mm

FLUE LENGTHS.

Max horizontal**

Max vertical**

Powered vertical†

COMBI ESP 24

9m

7.5m

22m

Note: The minimum front clearance when built in to a cupboard is 5mm from the cupboard door but 450mm overall clearance with the cupboard door open is required for servicing.

*Bottom clearance after installation can be reduced to

5mm. However, 100mm is required for servicing.

COMBI ESP 30

8m

7.5m

22m

COMBI ESP 35

6m

7.5m

22m

TECHNICAL SPECIFICATION.

Weight (packaged) kg

Max installation weight kg

CH output (kW) min/max

@ 70°C

CH output (kW) min/max

@ 40°C

DHW output (kW) max

DHW flow rate l/min.

35°C rise

SEDBUK rating (2005) %

SEDBUK rating

(2009/2012) %

NOx classification

Adjustable to LPG

Condensing boiler

Seasonal space heating efficiency class

Rated heat output kW

Seasonal space heating energy efficiency η son

%

Sound power level, indoors L

WA dB

Water heating energy efficiency class

24

93

45

A

89.0

CLASS 5

No

Yes

A

COMBI ESP 24

36.3

31.8

4.8 - 24.2

5.1 - 25.6

24.2

9.9

91

24

93

45

A

89.0

CLASS 5

Yes

Yes

A

COMBI ESP 30

36.5

32.0

6.1 - 24.2

6.4 - 25.6

30.3

12.4

91.1

Available flue extensions 0.5m, 1m and 2m. Multiple flue kits available.

** Each 90° elbow used is at the expense of 1000mm of straight flue run, and each 45° elbow is used at the expense of 600mm of straight flue run.

† Typical combined primary and secondary length. See installation instructions for more details. Note: The Flue Deflector Kit is used at the expense of 1000mm of straight flue run.

88.9

CLASS 5

No

Yes

A

24

93

44

A

COMBI EPS 35

36.5

32.0

7.1 - 24.2

7.5 - 25.6

35.3

14.5

91

9

10

TROUBLESHOOTING.

POINTS FOR THE

BOILER USER

Note. In line with our current

warranty policy we would ask that you check through the following guide to identify any problems external to the boiler prior to requesting a service engineer visit.

Should the problem be found to be other than with the appliance we reserve the right to levy a charge for the visit, or for any pre-arranged visit where access is not gained by the engineer.

NO HOT WATER

Check the mains switch (fused spur) is turned on and ensure switch mode control knob (D) (Control Panels: P.38) is in the summer or winter position

Is water coming out of the hot water tap when turned on?

NO

YES

See boiler “Fault Codes” section. If ‘0’ is displayed then contact Ideal Customer

Services Helpline if your appliance is under warranty or a Gas Safe

Registered Engineer, in IE a Registered

Gas Installer (RGII), if out of warranty

Contact a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII)

NO CENTRAL HEATING

Check the mains switch (fused spur) is turned on and ensure switch mode control knob (D)

(Control Panels: P.38) is in the winter position

Check the programmer (internal or external to the boiler) is in an “ON” position and the room thermostat is turned up

Does the boiler operate and provide central heating?

YES

Check the time settings on the programmer are as you require and adjust if necessary

NO

See boiler “Operation Modes” and

“Fault Codes” section. If “0” is displayed then contact a Gas

Safe Registered Engineer or in IE a Registered Gas Installer (RGII)

NO HOT WATER OR

CENTRAL HEATING

Check the fused spur is turned on and ensure switch mode control knob (D) (Control

Panels: P.38) is in the winter position

Does the boiler have a display showing on the front control panel?

NO

YES

See boiler “Operation

Modes” and “Fault Codes” section

Contact a Gas Safe

Registered Engineer or

in IE a Registered Gas

Installer (RGII)

11

12

OPERATIONS MODE.

DISPLAY CODE

ON THE BOILER

DESCRIPTION

The boiler is in standby mode awaiting either a central heating call or hot water demand.

The boiler has a call for central heating but the appliance has reached the desired temperature set on the boiler.

The boiler has a call for hot water but the appliance has reached the desired temperature set on the boiler.

The boiler is operating in central heating mode.

The boiler is operating in hot water mode.

The boiler is operating in frost mode.

FAULT CODES.

DISPLAY CODE ON THE BOILER DESCRIPTION ACTION

Outside sensor failure

Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe

Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

Low mains voltage Contact a qualified electrician or your electricity provider.

Unconfigured PCB Unconfigured PCB. Please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

Boiler resets in

15 minutes

1. Turn power off and on at the fused spur.

2. If the boiler fails to operate please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer RGII).

False flame lockout Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe

Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

FAULT CODES.

DISPLAY CODE ON THE BOILER DESCRIPTION ACTION

BCC activation fault Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe

Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

BCC fault Check the correct BCC is fitted for the boiler, and securely inserted into the slot at the front left of the PCB. (Identified by the label on the BCC). If yes then replace the current BCC with a new one correctly labelled for the boiler. If it is incorrect (turn off the power) then insert correctly into PCB after switching power back on restart the boiler.

Low water pressure Check system pressure is between 1 & 1.5bar on the pressure gauge.

If the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

Flow temperature overheat or no water flow

Flame loss

Is the boiler and CH heating system filled and all isolation vales and radiators open? If not then fill and vent the system and open all isolation valves and restart the boiler. Check that the pumps are rotating freely and the flow and return have a differential across the boiler in excess of 30°C.

1. Check other gas appliances in the house are working to confirm a supply is present in the property.

2. If other appliances do not work or there are no other appliances, check the gas supply is on at the meter and/or pre payment meter has credit. If the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a

Registered Gas Installer (RGII).

Fan fault

Flow thermistor

Return thermistor

Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe

Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe

Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe

Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

13

14

LOGIC CODE

COMBI ES 26 33 38.

HIGH EFFICIENCY COMBINATION BOILERS.

Designed to take the headache out of meeting Building Regulations, the Logic Code Combi ES from Ideal is a simple one-box solution, capable of supporting up to level 4 of the Code for Sustainable Homes.

LOGIC CODE

COMBI ES 26 33 38.

15

FEATURES.

COMPACT DIGITAL

DISPLAY

FROST

PROTECTION

FLUE

VARIANTS

LPG

CONVERSION*

NOx

CLASS 5

SPECIFICATION.

• Complete range of Logic combination boilers for new build developers

EASY TO INSTALL

• One single appliance to install – quick

• Achieves optimum SAP and DER ratings for standard combination boiler usage and easy

• Built-in pipework; no extra space at the

• Higher DHW fl ow rates than standard boiler – approximately 10% increase side of the product needed

• Standard combination connections

RELIABLE

• Energy Saving Trust endorsed product

• High DHW effi ciency - reduced running costs

• No additional maintenance requirement

• Compact and light solution for new build or retrofi t installations

• Less waste DHW water as DHW inlet is preheated

• Reduced pluming on DHW

• ErP compliant

* Available with 38 kW model.

16

CLEARANCES AND DIMENSIONS.

DIMENSIONS IN MM

DIMENSIONS:

Height: 830mm

Width: 395mm

Depth: 278mm

Note: The minimum front clearance when built in to a cupboard is 5mm from the cupboard door but 450mm overall clearance with the cupboard door open is required for servicing.

*Bottom clearance after installation can be reduced to 5mm. However, 100mm is required for servicing.

FLUE LENGTHS.

Max horizontal**

Max vertical**

Powered vertical†

CODE COMBI ES 26 CODE COMBI ES 33 CODE COMBI ES 38

9m

7.5m

22m

8m

7.5m

22m

6m

7.5m

22m

TECHNICAL SPECIFICATION.

Weight (packaged) kg

Max installation weight kg

CH output (kW) min/max

@ 70°C

CH output (kW) min/max

@ 40°C

DHW output (kW) max

DHW flow rate l/min.

35°C rise

SEDBUK rating (2005)

SEDBUK rating

(2009/2012) %

NOx classification

Adjustable to LPG

Condensing boiler

Seasonal space heating efficiency class

Rated heat output kW

Seasonal space heating energy efficiency η son

%

Sound power level, indoors L

WA dB

Water heating energy efficiency class

CODE COMBI

ES 26

39.5

34.7

4.8 - 24.2

5.1 - 25.6

26.1

10.7

91

89.0

CLASS 5

No

Yes

A

24

93

45

A

CODE COMBI

ES 33

39.7

34.9

6.1 - 24.2

6.4 - 25.6

32.7

13.4

91.1

89.0

CLASS 5

No

Yes

A

24

93

45

A

Multiple flue kits available.

** Each 90° elbow used is at the expense of 1000mm of straight flue run, and each 45° elbow is used at the expense of 600mm of straight flue run.

† Typical combined primary and secondary length. See installation instructions for more details. Note: The Flue Deflector Kit is used at the expense of 1000mm of straight flue run.

CODE COMBI

ES 38

39.7

34.9

7.1 - 24.2

7.5 - 25.6

38.2

15.7

91

88.9

CLASS 5

Yes

Yes

A

24

93

44

A

17

18

TROUBLESHOOTING.

POINTS FOR THE

BOILER USER

Note. In line with our current

warranty policy we would ask that you check through the following guide to identify any problems external to the boiler prior to requesting a service engineer visit.

Should the problem be found to be other than with the appliance we reserve the right to levy a charge for the visit, or for any pre-arranged visit where access is not gained by the engineer.

NO HOT WATER

Check the mains switch (fused spur) is turned on and ensure switch mode control knob (D) (Control Panels: P.38) is in the summer or winter position

Is water coming out of the hot water tap when turned on?

YES

NO

See boiler “Fault Codes” section. If ‘0’ is displayed then contact Ideal Customer

Services Helpline if your appliance is under warranty or a Gas Safe

Registered Engineer, in IE a Registered

Gas Installer (RGII), if out of warranty

Contact a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII)

NO CENTRAL HEATING

Check the mains switch (fused spur) is turned on and ensure switch mode control knob (D)

(Control Panels: P.38) is in the winter position

Check the programmer (internal or external to the boiler) is in an “ON” position and the room thermostat is turned up

Does the boiler operate and provide central heating?

YES

Check the time settings on the programmer are as you require and adjust if necessary

NO

See boiler “Operation Modes” and

“Fault Codes” section. If “0” is displayed then contact a Gas

Safe Registered Engineer or in IE a Registered Gas Installer (RGII)

NO HOT WATER OR

CENTRAL HEATING

Check the fused spur is turned on and ensure switch mode control knob (D) (Control

Panels: P.38) is in the winter position

Does the boiler have a display showing on the front control panel?

NO

YES

See boiler “Operation

Modes” and “Fault Codes” section

Contact a Gas Safe

Registered Engineer or

in IE a Registered Gas

Installer (RGII)

19

20

OPERATIONS MODE.

DISPLAY CODE

ON THE BOILER

DESCRIPTION

The boiler is in standby mode awaiting either a central heating call or hot water demand.

The boiler has a call for central heating but the appliance has reached the desired temperature set on the boiler.

The boiler has a call for hot water but the appliance has reached the desired temperature set on the boiler.

The boiler is operating in central heating mode.

The boiler is operating in hot water mode.

The boiler is operating in frost mode.

FAULT CODES.

DISPLAY CODE ON THE BOILER DESCRIPTION ACTION

Outside sensor failure

Reset the appliance - if the boiler fails to operate then please contact Ideal(if under warranty) or alternatively a Gas Safe

Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

Low mains voltage Contact a qualified electrician or your electricity provider.

Unconfigured PCB Unconfigured PCB. Please contact Ideal(if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

No water flow thermistor

Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe

Registered Engineer if outside of the warranty period.

In IE contact a Registered Gas Installer (RGII).

21

FAULT CODES.

DISPLAY CODE ON THE BOILER DESCRIPTION

Boiler resets in

15 minutes

ACTION

1. Turn power off and on at the fused spur.

2. If the boiler fails to operate please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

False flame lockout Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe

Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

BCC activation fault Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe

Registered Engineer if outside of the warranty period.

In IE contact a Registered Gas Installer (RGII).

BCC fault Check the correct BCC is fitted for the boiler, and securely inserted into the slot at the front left of the PCB. (Identified by the label on the BCC). If yes then replace the current BCC with a new one correctly labelled for the boiler. If it is incorrect (turn off the power) then insert correctly into PCB after switching power back on restart the boiler.

Low water pressure Check system pressure is between 1 & 1.5bar on the pressure gauge. If the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas

Installer (RGII).

Flow temperature overheat or no water flow

Flame loss

Is the boiler and CH heating system filled and all isolation vales and radiators open? If not then fill and vent the system and open all isolation valves and restart the boiler. Check that the pumps are rotating freely and the flow and return have a differential across the boiler in excess of 30°C.

1. Check other gas appliances in the house are working to confirm a supply is present in the property.

2. If other appliances do not work or there are no other appliances, check the gas supply is on at the meter and/or pre payment meter has credit. If the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas

Installer (RGII).

Fan fault Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe

Registered Engineer if outside of the warranty period.

In IE contact a Registered Gas Installer (RGII).

Flow thermistor Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe

Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

Return thermistor Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe

Registered Engineer if outside of the warranty period.

In IE contact a Registered Gas Installer (RGII).

22

LOGIC SYSTEM 15 18 24 30.

HIGH EFFICIENCY SYSTEM BOILERS.

The Logic System range of appliances from Ideal provide a simple and reliable solution for a wide variety of sealed domestic systems.

LOGIC SYSTEM 15 18 24 30.

FEATURES.

COMPACT DIGITAL

DISPLAY

FROST

PROTECTION

FLUE

VARIANTS

LPG

CONVERSION**

NOx

CLASS 5

SPECIFICATION.

Digital display and simple diagnostics

Fully modulating operation down

to 4.8 kW*

• Weather compensation kit option

RELIABLE

• Energy Saving Trust endorsed product

• Boiler frost protection

• Built-in condensate trap

• Latest generation Honeywell gas valve

• ErP compliant

• Two stage fl ame sensing for better

reliability

EASY TO INSTALL

• Compact cupboard fi t

• Wide range of fl ueing options

• Concealed pipe connections

• Low lift weight (27.7kg)†

• Preformed copper tails

• LPG Conversion kit available for 30 kW

boilers (System IE 24 kW)

• Stand off kit and pre-pipe options

• Pre-wired mains lead

• Easy Access to PRV and AAV

• Universal condensate connection

23

* (30 kW only - 6.1 kW). ** Available with IE 24 & 30 kW models.

† Weight with front panel removed.

24

CLEARANCES AND DIMENSIONS.

DIMENSIONS IN MM

DIMENSIONS:

Height: 700mm

Width: 395mm

Depth: 278mm

FLUE LENGTHS.

Note: The minimum front clearance when built in to a cupboard is 5mm from the cupboard door but 450mm overall clearance with the cupboard door open is required for servicing.

*Bottom clearance after installation can be reduced to

5mm. However, 100mm is required for servicing.

Max horizontal

Max vertical

Powered vertical

SYSTEM 15

9m

7.5m

22m

SYSTEM 18

9m

7.5m

22m

SYSTEM 24

9m

7.5m

22m

SYSTEM 30

8m

7.5m

22m

Max horizontal

Max vertical

Powered vertical

SYSTEM 15

9m

7.5m

22m

SYSTEM 18

9m

7.5m

22m

TECHNICAL SPECIFICATION.

Weight (packaged) kg

Max installation weight kg

CH output (kW) min/max

@ 70°C

CH output (kW) min/max

@ 40°C

DHW output (kW) max

DHW flow rate l/min.

35°C rise

SEDBUK rating (2005) %

SEDBUK rating

(2009/2012) %

NOx classification

Adjustable to LPG

Condensing boiler

Seasonal space heating efficiency class

Rated heat output kW

Seasonal space heating energy efficiency η son

%

Sound power level, indoors L

WA dB

Water heating energy efficiency class

SYSTEM 15

89.3

CLASS 5

No

Yes

A

15

93

41 n/a

34.1

27.7

4.8 - 15.0

5.1 - 15.9 n/a n/a

91.1

SYSTEM 18

89.2

CLASS 5

No

Yes

A

18

92

42 n/a

34.1

27.7

4.8 - 18.0

5.1 - 19.1

n/a n/a

91

SYSTEM 24

89.5

CLASS 5

Yes

Yes

A

24

93

45 n/a

34.1

27.7

4.8 - 24.2

5.1 - 25.6

n/a n/a

91

SYSTEM 30

89.6

CLASS 5

Yes

Yes

A

30

93

45 n/a

34.1

27.7

6.1 - 30.3

6.4 - 31.0

n/a n/a

91.1

25

Multiple flue kits available.

SYSTEM 24

9m

7.5m

22m

SYSTEM 30

8m

7.5m

22m

26

TROUBLESHOOTING.

POINTS FOR THE

BOILER USER

Note. In line with our current warranty

policy we would ask that you check through the following guide to identify any problems external to the boiler prior to requesting a service engineer visit. Should the problem be found to be other than with the appliance we reserve the right to levy a charge for the visit, or for any prearranged visit where access is not gained by the engineer.

NO HOT WATER

Check the mains switch (fused spur) is turned on and ensure mode control knob (B) (Control Panels: P.39) is in the ON position

Check the programmer is in an “ON” position and the cylinder thermostat is turned up

Does the boiler operate and provide hot water?

YES

Check the time settings on the programmer are as you require and adjust if necessary

NO

See boiler “Operation Modes” and

“Fault Codes” section. If “0” is displayed then contact a Gas Safe

Registered Engineer or in IE a

Registered Gas Installer (RGII)

NO CENTRAL HEATING

Check the mains switch (fused spur) is turned on and ensure mode control knob (B) (Control

Panels: P.39) is in the

ON position

Check the programmer is in an “ON” position and the room thermostat is turned up

27

Does the boiler operate and provide central heating?

YES

Check the time settings on the programmer are as you require and adjust if necessary

NO

See boiler “Operation Modes” and “Fault Codes” section. If “0” is displayed then contact a Gas

Safe Registered Engineer or in

IE a Registered Gas Installer

(RGII)

OPERATIONS MODE.

DISPLAY CODE

ON THE BOILER

DESCRIPTION

The boiler is in standby mode awaiting either a central heating call or hot water demand.

The boiler has a call for central heating / hot water but the appliance has reached the desired temperature set on the boiler.

The boiler is operating for central heating / hot water.

The boiler is operating in frost mode.

28

FAULT CODES.

DISPLAY CODE ON THE BOILER DESCRIPTION

Boiler chip card

(BCC) not fitted

ACTION

Please contact Ideal (if under warranty) or alternatively a Gas

Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

Outside sensor failure

Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe

Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

Low mains voltage Contact a qualified electrician or your electricity provider.

PCB fault PCB Fault. Please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period.

In IE contact a Registered Gas Installer (RGII).

Boiler resets in 15 minutes

1. Turn power off and on at the fused spur.

2. If the boiler fails to operate please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas

Installer (RGII).

False flame lockout Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe

Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

BCC activation fault Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe

Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

BCC fault Check system pressure is between 1 & 1.5 bar on the pressure gauge. If the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas

Installer (RGII).

29

DISPLAY CODE ON THE BOILER DESCRIPTION ACTION

Low water pressure Check system pressure is between 1 & 1.5bar on the pressure gauge. If the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas

Installer (RGII).

Flow temperature overheat

Is the boiler and CH heating system filled and all isolation vales and radiators open? If not then fill and vent the system and open all isolation valves and restart the boiler. Check that the pumps are rotating freely and the flow and return have a differential across the boiler in excess of 30°C.

Flame loss 1. Check other gas appliances in the house are working to confirm a supply is present in the property.

2. If other appliances do not work or there are no other appliances, check the gas supply is on at the meter and/or pre payment meter has credit. If the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas

Installer (RGII).

Fan fault

Control / no flow thermistor

Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe

Registered Engineer if outside of the warranty period.

In IE contact a Registered Gas Installer (RGII).

Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe

Registered Engineer if outside of the warranty period.

In IE contact a Registered Gas Installer (RGII).

Return thermistor Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe

Registered Engineer if outside of the warranty period.

In IE contact a Registered Gas Installer (RGII).

30

LOGIC HEAT 12 15 18 24 30.

HIGH EFFICIENCY HEAT BOILERS.

Designed to be installed with the minimum of fuss, Logic appliances offer a speedy installation.

LOGIC HEAT 12 15 18 24 30.

FEATURES.

COMPACT DIGITAL

DISPLAY

FROST

PROTECTION

FLUE

VARIANTS

LPG

CONVERSION*

DIRECT

REAR FLUE

NOx

CLASS 5

SPECIFICATION.

Fully modulating operation down to 4.8 kW**

Weather compensation kit option

Water fl ow sensor

Four optional language user

instructions†

RELIABLE

• Energy Saving Trust endorsed product

• Boiler frost protection

• Two stage fl ame sensing for greater

reliability

• Latest generation Honeywell gas valve

• ErP compliant

EASY TO INSTALL

• Compact cupboard fi t

• Direct 80mm diameter rear fl ue option

• Wide range of fl ueing options

• Low lift weight (22.8kg)††

• Top system connections

• 75mm deep translucent condensate

siphon

• Stand off kit

• Terminal wall plate kit

• Security bracket kit

• Low minimum head requirement

• LPG conversion kit available for

24 kW & 30 kW boilers

31

* Available with 24 & 30 kW models. ** (30 kW only - 6.1 kW).

† Available to download from www.idealboilers.com †† Weight with front panel removed.

32

CLEARANCES AND DIMENSIONS.

DIMENSIONS IN MM

DIMENSIONS:

Height: 700mm

Width: 395mm

Depth: 278mm

FLUE LENGTHS.

Note: The minimum front clearance when built in to a cupboard is 5mm from the cupboard door but 450mm overall clearance with the cupboard door open is required for servicing.

*Bottom clearance after installation can be reduced to 5mm. However, 100mm is required for servicing.

** Rear flue option - top clearance 100mm.

Max horizontal

Max vertical

Powered vertical

HEAT 12

9m

7.5m

22m

HEAT 15

9m

7.5m

22m

HEAT 18

9m

7.5m

22m

HEAT 24

9m

7.5m

22m

HEAT 30

8m

7.5m

22m

Max horizontal

Max vertical

Powered vertical

HEAT 12

9m

7.5m

22m

HEAT 15

9m

7.5m

22m

HEAT 18

9m

7.5m

22m

TECHNICAL SPECIFICATION.

HEAT 12

Weight (packaged) kg 28.5

Max installation weight kg

CH output (kW) min/max

@ 70°C

CH output (kW) min/max

@ 40°C

DHW output (kW) max

DHW flow rate l/min.

35°C rise

SEDBUK rating (2005) %

SEDBUK rating

(2009/2012) %

NOx classification

22.8

4.8 - 12.0

5.1 - 13.0

n/a n/a

91.2

89.4

CLASS 5

Adjustable to LPG

Condensing boiler

Seasonal space heating efficiency class

Rated heat output kW

Seasonal space heating energy efficiency η son

%

Sound power level, indoors L

WA dB

Water heating energy efficiency class

No

Yes

A

12

92

40 n/a

HEAT 18

89.2

CLASS 5

No

Yes

A

18

92

42 n/a

28.5

22.8

4.8 - 18.0

5.1 - 19.1

n/a n/a

91

HEAT 15

89.3

CLASS 5

No

Yes

A

15

93

41 n/a

28.5

22.8

4.8 - 15.0

5.1 - 15.9

n/a n/a

91.1

HEAT 30

89.6

CLASS 5

Yes

Yes

A

30

93

45 n/a

28.5

22.8

6.1 - 30.3

6.4 - 31.0

n/a n/a

91.1

HEAT 24

89.5

CLASS 5

Yes

Yes

A

24

93

45 n/a

28.5

22.8

4.8 - 24.2

5.1 - 25.6

n/a n/a

91

33

Multiple flue kits available.

HEAT 24

9m

7.5m

22m

HEAT 30

8m

7.5m

22m

34

TROUBLESHOOTING.

POINTS FOR THE BOILER USER

Note. In line with our current warranty policy we would ask that you check

through the following guide to identify any problems external to the boiler prior to requesting a service engineer visit. Should the problem be found to be other than with the appliance we reserve the right to levy a charge for the visit, or for any pre-arranged visit where access is not gained by the engineer.

NO CENTRAL HEATING OR

HOT WATER

Check the mains switch (fused spur) is turned on and ensure mode control knob (B)

(Control Panels: P.39) is in the

ON position

Check the Timer is in an

“ON” position, and the room thermostat is turned up

Does the boiler operate and provide central heating?

YES

Check the time settings on the programmer are as you require and adjust if necessary

NO

See boiler “Operation Modes” and “Fault Codes” section. If “0” is displayed then contact a Gas

Safe Registered Engineer or in

IE a Registered Gas Installer

(RGII)

OPERATIONS MODE.

DISPLAY CODE

ON THE BOILER

DESCRIPTION

The boiler is in standby mode awaiting either a central heating call or hot water demand.

The boiler has a call for central heating / hot water but the appliance has reached the desired temperature set on the boiler.

The boiler is operating for central heating / hot water.

35

The boiler is operating in frost mode.

FAULT CODES.

DISPLAY CODE ON THE BOILER DESCRIPTION ACTION

BCC activation fault Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe

Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

BCC fault Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe

Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

Unconfigured PCB Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe

Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

Flame loss See Action - Fault Code L 2.

36

FAULT CODES.

DISPLAY CODE ON THE BOILER DESCRIPTION

Fan fault

Flow thermistor

ACTION

Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe

Registered Engineer if outside of the warranty period.

In IE contact a Registered Gas Installer (RGII).

Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe

Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

Return thermistor Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe

Registered Engineer if outside of the warranty period.

In IE contact a Registered Gas Installer (RGII).

Outside sensor failure

Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe

Registered Engineer if outside of the warranty period.

In IE contact a Registered Gas Installer (RGII).

Low mains voltage Contact a qualified electrician or your electricity provider.

PCB fault

Flow/return reversed

Please contact Ideal (if under warranty) or alternatively a Gas

Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII).

Please contact a Gas Safe Registered Engineer. In IE contact a

Registered Gas Installer (RGII).

No water flow Please contact Ideal (if under warranty) or alternatively a Gas

SafeRegistered Engineer if outside of the warranty period.

In IE contact a Registered Gas Installer (RGII).

37

DISPLAY CODE ON THE BOILER DESCRIPTION

Flow temperature overheat or unconfigured PCB

Flame loss

ACTION

Check system pressure is between 1 & 1.5bar on the pressure gauge. If the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas

Installer (RGII).

1. Check other gas appliances in the house are working to confirm a supply is present in the property.

2. If other appliances do not work or there are no other appliances, check the gas supply is on at the meter and/or pre payment meter has credit. If the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas

Safe Registered engineer if outside of the warranty period. In

IE contact a Registered Gas Installer (RGII).

Boiler resets in

15 minutes

1. Turn power off and on at the fused spur.

2. If the boiler fails to operate please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered

Gas Installer (RGII).

False flame lockout Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe

Registered Engineer if outside of the warranty period.

In IE contact a Registered Gas Installer (RGII).

38

BOILER CONTROLS.

LOGIC COMBI ESP/ LOGIC CODE COMBI ES.

24 30 35 26 33 38

BOILER CONTROLS

A. Blank

B. DHW Temperature Control

C. CH Temperature Control

D. Mode Control

E. Boiler Status

F. Burner ‘on’ Indicator

G. Economy Mode

A B E F C G D

In normal operation the boiler status display (E) will show the following codes: 0 – Standby – no demand for heat, C – Central Heating being supplied, D – DHW being supplied, F – boiler frost protection (boiler fi res if temperature is below 5°C).

If the pressure is seen to fall below the original installation pressure of

1-2 bar over a period of time then a water leak may be indicated. In this event conduct the re-pressurising procedure as show on page 4 of the

User Manual.

WINTER OPERATION: COMBI.

1. Ensure gas and electric supplies are available and on

(i.e. card meters are topped up).

2. Ensure boiler thermostat (C) is on and set two thirds of the way round.

3. Set room thermostat to desired temperature, normally between 20-23°C.

4. Control individual room via Thermostatic Radiator

Valves. 1 - Low, 2 - Low/Average, 3 - Average,

4 - Average/High, 5 - High.

5. Control the heating times by using programmer/clock and not by switching the boiler on and off.

6. For periods of intense cold leave the system on 24 hours a day. Switch the room thermostat down to 10°C overnight. This will maintain comfort levels and ensure the system doesn’t freeze.

(FOR FULL INSTRUCTION DETAILS REFER TO THE

IDEAL LOGIC USER GUIDE)

LOGIC SYSTEM.

15 18 24 30

BOILER CONTROLS

A. CH Temperature Control

B. Mode Control

C. Boiler Status

D. Burner ‘on’ Indicator

E. Economy Mode

A E C D B

In normal operation the boiler status display (C) will show the following codes: 0 – Standby – no demand for heat, C – Central Heating being supplied, F – boiler frost protection (boiler fires if temperature is below 5°C).

If the pressure is seen to fall below the original installation pressure of

1-2 bar over a period of time then a water leak may be indicated. In this event conduct the re-pressurising procedure as show on page 4 of the

User Manual.

LOGIC HEAT.

12 15 18 24 30

BOILER CONTROLS

A. Temperature Control

B. Mode Control

C. Boiler Status

D. Burner ‘on’ Indicator

E. Economy Mode

A E C D B

In normal operation the boiler status display (C) will show the following codes: 0 – Standby – no demand for heat, C – Central Heating being supplied.

39

40

COMBINATION BOILER

CONTROLS.

PROGRAMMABLE THERMOSTATS AND TIMERS.

We believe that choosing the right control to meet the needs of your customer is almost as important as choosing the right boiler; this is why our boilers are fully compatible with a range of thermostats and timers for the ultimate in home comfort.

MECHANICAL TIMER.

(Part No. 204839)

ErP: Class 0, no additional effi ciency.

Simple heating control through a plug in analogue timer. 24 hour tappet operation with off/timed/continuous periods.

ELECTRONIC TIMER.

(Part No. 204545)

ErP: Class 0, no additional effi ciency.

Easy to use heating control through a plug in digital timer. Plain text operating and diagnostics information. 7 day and up to 3 time periods/day. Automatic summer/ winter time update.

EXTERNAL

ROOM CONTROLS

RF MECHANICAL

PROGRAMMABLE

THERMOSTAT.

(Part No. 204824)

ErP: Class 1, 1% additional effi ciency.

If fi tted with Weather Compensation (Outdoor Sensor)

211326 ErP: Class 2, 2% additional effi ciency.

Wireless radio frequency (RF) analogue timer and room thermostat providing heat control. Easy to use 24 hour tappet control.

RF MECHANICAL

TIMER AND ROOM THERMOSTAT KITS.

(Part No. 208352)

ErP: Class 1, 1% additional effi ciency.

If fi tted with Weather Compensation (Outdoor Sensor) 211326

ErP: Class 2, 2% additional effi ciency.

tappet operation with off/timed continuous period.

compact design with LCD display and simple symbols to indicate the control.

RF ELECTRONIC

PROGRAMMABLE THERMOSTAT.

(Part No. 204789)

ErP: Class 5, 3% additional effi ciency.

If fi tted with Weather Compensation (Outdoor Sensor) 211326

ErP: Class 6, 4% additional effi ciency.

operating and diagnostics display. Automatic summer/winter time update.

COMBI, HEAT ONLY & SYSTEM CONTROLS.

WEATHER COMPENSATION OUTDOOR SENSOR.

(Part No. 211326 - combi models only)

ErP: Class 2, 2% additional effi ciency.

(Part No. 211332 - heat only and system models)

ErP: Class 2, 2% additional effi ciency.

The Logic and Logic Code Combi ES ranges provide weather compensation when fi tted with an outdoor sensor (which is available as an optional accessory).

Weather compensation works by measuring the temperature outside the home and adjusting the temperature (or fl ow) of the radiators inside.

If the weather is particularly cold outside, the outdoor sensor will communicate with the boiler intelligently to increase the radiator temperature. This process also works in reverse, as the outdoor temperature increases, the fl ow to the radiators too will decrease.

This process allows the system to operate more effi ciently by only heating to the minimum temperature necessary and also preventing spikes in heating activity.

41

42

LPG

CONVERSION KITS.

Designed for use with Logic combi, heat and system 24 & 30 kW boilers (combi ESP 30 kW only) and the new Code Combi ES 38 kW, the Ideal LPG (propane) conversion kit provides a simple and robust gas conversion solution.

With kits available inclusive of natural gas to LPG kits, and LPG to natural gas kits, these quick to install accessories provide a simple and pragmatic solution without the need for products to be adjusted.

Each kit contains specifi c components for each required boiler type.

FEATURES.

• Available for all product types (combi, heat & system)

• Suitable for most property sizes

• Fast & simple conversion with preset gas valve for no product adjustment

APPLICABLE MODELS.

• Logic Code Combi ES 38

• Logic Combi 24 & 30

• Logic Combi ESP 30

• Logic Heat 24 & 30

• Logic System IE 24

• Logic System 30

43

SPECIFICATION.

BOILER MODEL

Min. output (kW)

Max. output (kW)

Max DHW output (kW)

COMBI

24

4.8

24.2

24.2

COMBI

& ESP 30

6.1

24.2

30.3

CODE COMBI

ES 38

7.1

24.2

38.2

HEAT

24

4.8

24.2

N/A

HEAT

30

6.1

30.3

N/A

SYSTEM

IE 24

4.8

24.2

N/A

SYSTEM

30

6.1

30.3

N/A

NG-LPG

CONVERSION KIT

LOGIC CODE COMBI ES38

LOGIC COMBI 24 ErP

LOGIC COMBI 24

LOGIC COMBI 30 ErP

LOGIC COMBI 30

LOGIC COMBI ES & ESP30 ErP

LOGIC HEAT 24

LOGIC HEAT 30

LOGIC SYSTEM IE 24

LOGIC SYSTEM 30

PRODUCT

CODE

211382

213374

212115

213342

211370

213343

212114

211372

212113

211374

LPG-NG

CONVERSION KIT

LOGIC CODE COMBI ES38

LOGIC COMBI 24

LOGIC COMBI 30

LOGIC COMBI ES30

LOGIC HEAT 24

LOGIC HEAT 30

LOGIC SYSTEM 30

PRODUCT

CODE

177528

177868

177514

177525

177867

177516

177518

EACH KIT COMPRISES:

• Gas valve (preset operation)

• Burner injector

• BCC (boiler chip card)

• Data plate labels

• Instructions

• Washer (not pictured)

• ‘O’ ring (not pictured) during conversion.

Two data plate labels are provided in the kits inclusive of a new data plate providing LPG details and a label to retain boiler serial number identity.

44

FLUE SITING.

There are a substantial number of flueing options available for Ideal boiler ranges, giving excellent siting flexibility for almost all applications.

The range of options include standard and telescopic flues as well as roof flue and powered vertical flue options.

To ensure siting issues are kept to a minimum High Level Flue Outlet kit options and Flue

Deflector kits are available.

Minimum dimensions of flue terminal positions.

FLUE TERMINAL POSITION

1. Directly below, above or alongside an opening window, air vent or

other ventilation opening.

2. Below guttering, drain pipes or soil pipes.

BS5440-1 2008

3. Below eaves.

BS5440-1 2008

4. Below balconies or car port roof.

BS5440-1 2008

5. From vertical drain pipes or soil pipes.

BS5440-1 2008

6. From an internal or external corner or to a boundary alongside the

terminal.

BS5440-1 2008

7. Above ground, roof or balcony level.

8. From a surface or a boundary facing a terminal.

9. From a terminal facing a terminal.

10. From an opening in a car port (eg. door or window) into dwelling.

11. Vertically from a terminal on the same wall.

12. Horizontally from a terminal on the wall.

MIN. SPACING

300mm (12")

25mm (1")*

75mm (3")

25mm (1")*

200mm (8")

25mm (1")*

200mm (8")

25mm (1")*

150mm (6")

25mm (1")*

300mm (12")

300mm (12")

600mm (24")

1200mm (48")

1200mm (48")

1500mm (60")

300mm (12")

VERTICAL FLUES

13. Above the roof pitch with roof slope of all angles. Above flat roof.

14. From a single wall face.

From corner walls.

15. Below velux window.

16. Above or side of velux window.

300mm (12")

300mm (12")

300mm (12")

300mm (12")

2000mm (79")

600mm (24")

* Only one reduction down to 25mm is allowable per installation otherwise BS5440-1 2008 dimensions must be followed.

1

4

7

8/9

14

6

10

1

2/3

13

15/16

6

6

12

12

5

7

11

11

45

B

B

A

A

A A

A

B

A = 600mm

B = 2000mm

The flue terminal shall not penetrate the shaded area of the roof.

RF9807

If chimney penetrates dotted area such that A is less than 300mm, B shall not be less than 300mm.

46

FLUEING OPTIONS

LOGIC COMBI ESP, HEAT & SYSTEM.

HORIZONTAL

CONCENTRIC

100MM DIAMETER.

NOTE:

Lengths are from outside edge of turret to outside wall face.

Where extension D Packs are cut to length, flared end connector must be retained.

(FOR LOGIC HEAT ONLY - REAR OUTLET

FLUE (55/80) SEE P.66)

FLUE

Horizontal flue terminal (0.6m long)

Telescopic B pack flue (0.6m long)

Horizontal flue terminal (0.6m long)

+ 6 x Flue extension 1m (pack D)

Telescopic B pack flue (0.6m long)

+ 6 x Flue extension 1m (pack D)

Horizontal flue terminal (0.6m long)

+ 8 x Flue extension 1m (pack D)

Telescopic B pack flue (0.6m long)

+ 8 x Flue extension 1m (pack D)

Horizontal flue terminal (0.6m long)

+ 9 x Flue extension 1m (pack D)

Telescopic B pack flue (0.6m long)

+ 9 x Flue extension 1m (pack D)

IDEAL

PART NO.

208171

208169

208171

6 x 203129

208169

6 x 203129

208171

8 x 203129

208169

8 x 203129

208171

9 x 203129

208169

9 x 203129

MAXIMUM STRAIGHT

FLUE LENGTH (MM)

556

484

6256 (35 max length 6m)

6184 (35 max length 6m)

8186 (30 max length 8m)

8084 (30 max length 8m)

9000 (12-24 models)

9000 (12-24 models)

FLUEING OPTIONS

LOGIC COMBI ESP, HEAT & SYSTEM.

47

HORIZONTAL

FLUE WITH

1 X 90° ELBOW.

NOTE:

Lengths are sum of all straight lengths between outside edge of turret to outside wall face.

Numbers of extension D packs give flexibility of lengths of straight at either side of elbow.

Where extension D packs are cut to length, flared end connector must be retained.

FLUE

Horizontal flue terminal (0.6m long)

+ Flue 90° elbow kit (60/100)

Telescopic B pack flue (0.6m long)

+ Flue 90° elbow kit (60/100)

Horizontal flue terminal (0.6m long)

+ 5 x Flue extension 1m (pack D)

+ Flue 90° elbow kit (60/100)

Telescopic B pack flue (0.6m long)

+ 5 x Flue extension 1m (pack D)

+ Flue 90° elbow kit (60/100)

Horizontal flue terminal (0.6m long)

+ 7 x Flue extension 1m (pack D)

+ Flue 90° elbow kit (60/100)

Telescopic B pack flue (0.6m long)

+ 7 x Flue extension 1m (pack D)

+ Flue 90° elbow kit (60/100)

Horizontal flue terminal (0.6m long)

+ 8 x Flue extension 1m (pack D)

+ Flue 90° elbow kit (60/100)

Telescopic B pack flue (0.6m long)

+ 8 x Flue extension 1m (pack D)

+ Flue 90° elbow kit (60/100)

IDEAL

PART NO.

208171

203130

208169

203130

208171

5 x 203129

203130

208169

5 x 203129

203130

208171

7 x 203129

203130

208169

7 x 203129

203130

208171

8 x 203129

203130

208169

8 x 203129

203130

MAXIMUM STRAIGHT

FLUE LENGTH (MM)

556

484

5306 (35 max length 5m.

+ 1x 90° elbow)

5234 (35 max length 5m.

+ 1x 90° elbow)

7236 (30 max length 7m.

+ 1x 90° elbow)

7134 (30 max length 7m.

+ 1x 90° elbow)

8000 (12-24 models max length

8m. + 1x 90° elbow)

8000 (12-24 models max length

8m. + 1x 90° elbow)

48

FLUEING OPTIONS

LOGIC COMBI ESP, HEAT & SYSTEM.

HORIZONTAL

FLUE WITH

2 X 90° ELBOW.

NOTE:

Lengths are sum of all straight lengths between outside edge of turret to outside wall face.

Numbers of extension D packs give flexibility of lengths of straight at either side of elbow.

Where extension D packs are cut to length, flared end connector must be retained.

FLUE

Horizontal flue terminal (0.6m long)

+ 2 x Flue 90° elbow kit (60/100)

Telescopic B pack flue (0.6m long)

+ 2 x Flue 90° elbow kit (60/100)

Horizontal flue terminal (0.6m long)

+ 4 x Flue extension 1m (pack D)

+ 2 x Flue 90° elbow kit (60/100)

Telescopic B pack flue (0.6m long)

+ 4 x Flue extension 1m (pack D)

+ 2 x Flue 90° elbow kit (60/100)

Horizontal flue terminal (0.6m long)

+ 6 x Flue extension 1m (pack D)

+ 2 x Flue 90° elbow kit (60/100)

Telescopic B pack flue (0.6m long)

+ 6 x Flue extension 1m (pack D)

+ 2 x Flue 90° elbow kit (60/100)

Horizontal flue terminal (0.6m long)

+ 7 x Flue extension 1m (pack D)

+ 2 x Flue 90° elbow kit (60/100)

Telescopic B pack flue (0.6m long)

+ 7 x Flue extension 1m (pack D)

+ 2 x Flue 90° elbow kit (60/100)

IDEAL

PART NO.

208171

2 x 203130

208169

2 x 203130

208171

4 x 203129

2 x 203130

208169

4 x 203129

2 x 203130

208171

6 x 203129

2 x 203130

208169

6 x 203129

2 x 203130

208171

7 x 203129

2 x 203130

208169

7 x 203129

2 x 203130

MAXIMUM STRAIGHT

FLUE LENGTH (MM)

556

484

4356 (35 max length 4m.

+ 2x 90° elbow)

4284 (35 max length 4m.

+ 2x 90° elbow)

6286 (30 max length 6m.

+ 2x 90° elbow)

6184 (30 max length 6m.

+ 2x 90° elbow)

7000 (12-24 models max length

7m. + 2x 90° elbow)

7000 (12-24 models max length

7m. + 2x 90° elbow)

FLUEING OPTIONS

LOGIC COMBI ESP, HEAT & SYSTEM.

FLUE

Horizontal flue terminal (0.6m long)

+ 2 x Flue elbow 45° kit (60/100)

Telescopic B pack flue (0.6m long)

+ 2 x Flue elbow 45° kit (60/100)

Horizontal flue terminal (0.6m long)

+ 5 x Flue extension 1m (pack D)

+ 2 x Flue elbow 45° kit (60/100)

Telescopic B pack flue (0.6m long)

+ 5 x Flue extension 1m (pack D)

+ 2 x Flue elbow 45° kit (60/100)

Horizontal flue terminal (0.6m long)

+ 7 x Flue extension 1m (pack D)

+ 2 x Flue elbow 45° kit (60/100)

Telescopic B pack flue (0.6m long)

+ 7 x Flue extension 1m (pack D)

+ 2 x Flue elbow 45° kit (60/100)

Horizontal flue terminal (0.6m long)

+ 8 x Flue extension 1m (pack D)

+ 2 x Flue elbow 45° kit (60/100)

Telescopic B pack flue (0.6m long)

+ 8 x Flue extension 1m (pack D)

+ 2 x Flue elbow 45° kit (60/100)

49

HORIZONTAL

FLUE WITH

2 X 45° ELBOW.

NOTE:

Lengths are sum of all straight lengths between outside edge of turret to outside wall face.

Numbers of extension D packs give flexibility of lengths of straight at either side of elbow.

Where extension D packs are cut to length, flared end connector must be retained.

IDEAL

PART NO.

208171

203131

208169

203131

208171

5 x 203129

203131

208169

5 x 203129

203131

208171

7 x 203129

203131

208169

7 x 203129

203131

208171

8 x 203129

203131

208169

8 x 203129

203131

MAXIMUM STRAIGHT

FLUE LENGTH (MM)

556

484

5306 (35 max length 4.8m.

+ 2 x 45° elbow)

5234 (35 max length 4.8m.

+ 2 x 45° elbow)

7236 (30 max length 6.8m.

+ 2 x 45° elbow)

7134 (30 max length 6.8m.

+ 2 x 45° elbow)

7800 (12-24 models max length

7.8m. + 2 x 45° elbow)

7800 (12-24 models max length

7.8m. + 2 x 45° elbow

50

FLUEING OPTIONS

LOGIC COMBI ESP, HEAT & SYSTEM.

ROOF FLUE SYSTEM.

FLUE IDEAL

PART NO.

Roof flue kit (with vertical connector)

+ Weather collar

Roof flue kit

+ 7 x (max) Flue extension 1m (pack D)

+ Weather collar

211039

152258/152259*

211039

7 x 203129

152258/152259*

MAXIMUM

STRAIGHT

FLUE LENGTH

(MM)

1325

NOTE:

* 152258: Weather collar universal 100 dia (suits any roof pitch)

152259: Weather collar flat roof 100 dia

7500

ROOF FLUE SYSTEM

WITH 2 X 45° ELBOW.

FLUE IDEAL

PART NO.

MAXIMUM

STRAIGHT

FLUE LENGTH

(MM)

Roof flue kit (with vertical connector)

+ 6 x (max) Flue extension 1m (pack D)

+ 2 x Flue elbow 45° kit (60/100)

+ Weather collar

211039

6 x 203129

203131

152258/152259*

NOTE:

* 152258: Weather collar universal 100 dia (suits any roof pitch)

152259: Weather collar flat roof 100 dia

6300

FLUEING OPTIONS

LOGIC COMBI ESP, HEAT & SYSTEM.

51

POWERED

VERTICAL

FLUE SYSTEM.

FLUE

Vertical powered flue kit

+ Flue vertical connector

+ Flue powered vertical terminal

100 dia

+ Weather collar

+ Extension pack D

+ Flue extension pipe 80 dia (pair)†

IDEAL

PART NO.

MAXIMUM

STRAIGHT

FLUE LENGTH

(MM)

203136

208175

203134

152258/152259*

203129

203142

Primary and secondary flue combined maximum

22mm**

NOTE: Allows the boiler to be sited in a position where no access to an outside wall is available. Permits the concentric flue to run vertically from the top of the boiler and obtain air supply within the roof space, the secondary flue continuing to the external flue terminal. Offset applications are permissible though the maximum length is reduced.

* 152258: Weather collar universal 100 dia (suits any roof pitch)

152259: Weather collar flat roof 100 dia

Where extension D packs are cut to length, the flared end connector must be retained.

† Secondary flue extension pipes are available in 0.5, 1 and 2 metre lengths.

** See installation instructions for maximum primary and maximum secondary flue lengths.

52

FLUEING & INSTALLATION ACCESSORIES

LOGIC COMBI ESP, HEAT & SYSTEM.

Telescopic B pack flue

(0.6m long)

Horizontal flue terminal

(0.6m long)

Telescopic horizontal flue terminal (1m long)

Flue elbow 90° kit (60/100) packaged

Roof flue kit inc. vertical connector

Vertical

Powered flue kit

Rear flue outlet kit (55/80)*

Flue finishing kit

(55/80)*

Ideal part no.

208169

Flue elbow 45° kit (60/100) packaged (pair)

Ideal part no.

208171

Flue extension

1m (Pack D)

Ideal part no.

208174

Flue vertical connector

Ideal part no.

203130

Flue powered vertical terminal

100 dia

Ideal part no.

211039

Flue extension pipe

80 dia (pair) twin/vertical

Ideal part no.

203136

Flue extension

0.5m or 2m

(Pack D)

Ideal part no.

205990

Stand off kit

1

Ideal part no.

206151

Stand off kit 2

Inc. piping

Ideal part no.

203131

Flue deflector

60 dia

Ideal part no.

203129

Weather collar

(universal)

100 dia

Ideal part no.

208175

Weather collar

(flat roof) 100 dia

Ideal part no.

203134

Flue finishing kit

Ideal part no.

203142

Condensate pump kit

Ideal part no.

0.5m 211037

2m 211038

Terminal wall plate

RS replacement kit

Ideal part no.

211103

Pressure gauge

3 extension kit

Ideal part no.

211101

Weather compensation kit

Ideal part no.

208176

Ideal part no.

152258

Ideal part no.

152259

Ideal part no.

155988

Ideal part no.

159991

Ideal part no.

211328

Combi & System

206164

Heat

Ideal part no.

206712

Ideal part no.

211326

Combi

211332

Heat & System

FLUEING & INSTALLATION ACCESSORIES

LOGIC COMBI ESP, HEAT & SYSTEM.

Telescopic B pack flue

(0.6m long)

Horizontal flue terminal

(0.6m long)

Telescopic horizontal flue terminal (1m long)

Flue elbow 90° kit (60/100) packaged

Roof flue kit inc. vertical connector

Vertical

Powered flue kit

Rear flue outlet kit (55/80)*

Flue finishing kit

(55/80)*

53

Ideal part no.

208169

Flue elbow 45° kit (60/100) packaged (pair)

Ideal part no.

208171

Flue extension

1m (Pack D)

Ideal part no.

208174

Flue vertical connector

Ideal part no.

203130

Flue powered vertical terminal

100 dia

Ideal part no.

211039

Flue extension pipe

80 dia (pair) twin/vertical

Ideal part no.

203136

Flue extension

0.5m or 2m

(Pack D)

Ideal part no.

205990

Stand off kit

1

Ideal part no.

206151

Stand off kit 2

Inc. piping

Ideal part no.

203131

Flue deflector

60 dia

Ideal part no.

203129

Weather collar

(universal)

100 dia

Ideal part no.

208175

Weather collar

(flat roof) 100 dia

Ideal part no.

203134

Flue finishing kit

Ideal part no.

203142

Condensate pump kit

Ideal part no.

0.5m 211037

2m 211038

Terminal wall plate

RS replacement kit

Ideal part no.

211103

Pressure gauge

3 extension kit

Ideal part no.

211101

Weather compensation kit

Ideal part no.

208176

Ideal part no.

152258

Ideal part no.

152259

Ideal part no.

155988

Ideal part no.

159991

Ideal part no.

211328

Combi & System

206164

Heat

Ideal part no.

206712

Ideal part no.

211326

211332

Combi

Heat & System

1

Combi & System only, for Heat models - 206153.

2

Combi only, for System models only 211330.

3 Logic Combi & System only.

54

FLUEING & INSTALLATION ACCESSORIES

LOGIC COMBI ESP, HEAT & SYSTEM.

INSTALLATION

ACCESSORIES

Pre-piping kit

Pre-piping kit

Security bracket kit

IDEAL

PART NO.

211041

211331

205217

COMBI HEAT SYSTEM

INSTALLATION

ACCESSORIES

OpenTherm harness kit

PRV wall outlet pipe kit

DHW expansion vessel kit

IDEAL

PART NO.

211327

205126

205419

COMBI HEAT SYSTEM

Balcony flue outlet kit

Ideal part no. 208177

FLUEING & INSTALLATION ACCESSORIES

LOGIC COMBI ESP, HEAT & SYSTEM.

Soffit kit

Ideal part no. 211302

Raised horizontal flue outlet kit

NOTE:

A 1 metre vertical pipe is supplied as standard. Both horizontal and vertical lengths can be extended using extension pack D.

Refer to installation instructions for maximum lengths.

Ideal part no. 208290

55

56

ACCESSORIES

HIGH LEVEL FLUE OUTLET KIT.

These easy to install kits allow the boiler flue outlet to be extended external to the building, upwards to provide a flue exit at high level, overcoming problems associated with plume emission. The kit can be simply fitted retrofitted if necessary (excluding rear outlet of

Logic Heat).

An external 60mm diameter flue leads from the boiler terminal (which includes a 90° elbow at the flue exit) to terminate with a 90° elbow complete with grille. Push fit one metre extension pipes are used as required, and the fixing clips supplied support the system from the wall.

Both 90° and 45° elbows are available to provide routing options.

THE KIT COMPRISES:

Flue elbow - 1 off

60mm flue exit elbow - 1 off

60mm horizontal flue exit - 1 off

60mm x 500mm flue outlet extension pipe - 1 off

This kit is specified for use with the normal standard B pack.

The standard terminal nose is replaced with the high level terminal.

Diagram representative only.

IMPORTANT

Flue must always slope at least 1

1 /

2 back to the

˚ boiler

VERTICAL

HORIZONTAL

LEFT OR RIGHT 45˚ LEFT OR RIGHT

LOGIC (ALL MODELS)

High level flue outlet kit

Logic Heat rear flue outlet (55/80) ONLY high level flue outlet kit (55/80)

Flue extension kit 60 dia (1m) - for high level flue outlet kit

High level 90° elbow

High level 45° elbow

IDEAL PART NO.

208178

205989

203228

203229

203230

LOGIC (ALL MODELS)

90° elbow

45° elbow (pair)

METRES

1.4

1.25

If additional elbows to those supplied in the high level flue outlet kit are used, deduct the following resistances (metres) from the maximum boiler flue length.

57

58

FLUEING OPTIONS

LOGIC HEAT.

REAR OUTLET

FLUE TERMINAL

(55/80) - 80MM.

FLUE

Rear outlet flue outlet kit 55/80

IDEAL

PART NO.

205990

NOTE:

Length is wall thickness. Minimum wall thickness permissible is 115mm.

No extensions are permitted.

MAXIMUM STRAIGHT

FLUE LENGTH (MM)

442

FLUEING ACCESSORIES

Rear outlet flue terminal (55/80)

Flue finishing kit (55/80)

IDEAL PART NO.

205990

206151

LOGIC HEAT ONLY

High level outlet kit (55/80)

For 1m extension and elbows use standard parts 203228/9 & 30.

IDEAL PART NO.

205989

FLUEING OPTIONS

LOGIC CODE COMBI ES.

HORIZONTAL

CONCENTRIC

100MM DIAMETER.

NOTE:

Lengths are from outside edge of turret to outside wall face.

Where extension D Packs are cut to length, flared end connector must be retained.

59

FLUE

Horizontal flue terminal (0.6m long)

Horizontal flue terminal (0.6m long)

+ 6 x Flue extension 1m (pack D)

Horizontal flue terminal (0.6m long)

+ 8 x Flue extension 1m (pack D)

Horizontal flue terminal (0.6m long)

+ 9 x Flue extension 1m (pack D)

IDEAL

PART NO.

208171

208171

6 x 203129

208171

8 x 203129

208171

9 x 203129

MAXIMUM STRAIGHT

FLUE LENGTH (MM)

556

6256 (38 max length 6m)

8186 (33 max length 8m)

9000 (26 models)

60

FLUEING OPTIONS

LOGIC CODE COMBI ES.

HORIZONTAL

FLUE WITH

1 X 90° ELBOW.

NOTE:

Lengths are sum of all straight lengths between outside edge of turret to outside wall face.

Numbers of extension D packs give flexibility of lengths of straight at either side of elbow.

Where extension D packs are cut to length, flared end connector must be retained.

FLUE

Horizontal flue terminal (0.6m long)

+ Flue 90° elbow kit (60/100)

Horizontal flue terminal (0.6m long)

+ 5 x Flue extension 1m (pack D)

+ Flue 90° elbow kit (60/100)

Horizontal flue terminal (0.6m long)

+ 7 x Flue extension 1m (pack D)

+ Flue 90° elbow kit (60/100)

Horizontal flue terminal (0.6m long)

+ 8 x Flue extension 1m (pack D)

+ Flue 90° elbow kit (60/100)

IDEAL

PART NO.

208171

203130

208171

5 x 203129

203130

208171

7 x 203129

203130

208171

8 x 203129

203130

MAXIMUM STRAIGHT

FLUE LENGTH (MM)

556

5306 (38 max length 5m.

+ 1x 90° elbow)

7236 (33 max length 7m.

+ 1x 90° elbow)

8000 (26 models max length

8m. + 1x 90° elbow)

FLUEING OPTIONS

LOGIC CODE COMBI ES.

61

HORIZONTAL

FLUE WITH

2 X 90° ELBOW.

NOTE:

Lengths are sum of all straight lengths between outside edge of turret to outside wall face.

Numbers of extension D packs give flexibility of lengths of straight at either side of elbow.

Where extension D packs are cut to length, flared end connector must be retained.

FLUE

Horizontal flue terminal (0.6m long)

+ 2 x Flue 90° elbow kit (60/100)

Horizontal flue terminal (0.6m long)

+ 4 x Flue extension 1m (pack D)

+ 2 x Flue 90° elbow kit (60/100)

Horizontal flue terminal (0.6m long)

+ 6 x Flue extension 1m (pack D)

+ 2 x Flue 90° elbow kit (60/100)

Horizontal flue terminal (0.6m long)

+ 7 x Flue extension 1m (pack D)

+ 2 x Flue 90° elbow kit (60/100)

IDEAL

PART NO.

208171

2 x 203130

208171

4 x 203129

2 x 203130

208171

6 x 203129

2 x 203130

208171

7 x 203129

2 x 203130

MAXIMUM STRAIGHT

FLUE LENGTH (MM)

556

4356 (38 max length 4m.

+ 2x 90° elbow)

6286 (33 max length 6m.

+ 2x 90° elbow)

7000 (26 models max length 7m.

+ 2x 90° elbow)

62

FLUEING OPTIONS

LOGIC CODE COMBI ES.

HORIZONTAL

FLUE WITH

2 X 45° ELBOW.

NOTE:

Lengths are sum of all straight lengths between outside edge of turret to outside wall face.

Numbers of extension D packs give flexibility of lengths of straight at either side of elbow.

Where extension D packs are cut to length, flared end connector must be retained.

FLUE

Horizontal flue terminal (0.6m long)

+ 2 x Flue elbow 45° kit (60/100)

Horizontal flue terminal (0.6m long)

+ 5 x Flue extension 1m (pack D)

+ 2 x Flue elbow 45° kit (60/100)

Horizontal flue terminal (0.6m long)

+ 7 x Flue extension 1m (pack D)

+ 2 x Flue elbow 45° kit (60/100)

Horizontal flue terminal (0.6m long)

+ 8 x Flue extension 1m (pack D)

+ 2 x Flue elbow 45° kit (60/100)

IDEAL

PART NO.

208171

203131

208171

5 x 203129

203131

208171

7 x 203129

203131

208171

8 x 203129

203131

MAXIMUM STRAIGHT

FLUE LENGTH (MM)

556

5306 (35 max length 4.8m.

+ 2 x 45° elbow)

7236 (30 max length 6.8m.

+ 2 x 45° elbow)

7800 (12-24 models max length

7.8m. + 2 x 45° elbow)

FLUEING OPTIONS

LOGIC CODE COMBI ES.

ROOF FLUE SYSTEM.

FLUE IDEAL

PART NO.

Roof flue kit (with vertical connector)

+ Weather collar

Roof flue kit

+ Flue vertical connector

+ 7 x (max) Flue extension 1m (pack D)

+ Weather collar

211039

152258/152259*

203132

208175

7 x 203129

152258/152259*

MAXIMUM

STRAIGHT

FLUE LENGTH

(MM)

1325

7500

NOTE:

* 152258: Weather collar universal 100 dia (suits any roof pitch)

152259: Weather collar flat roof 100 dia

ROOF FLUE SYSTEM

WITH 2 X 45° ELBOW.

FLUE IDEAL

PART NO.

Roof flue kit (with vertical connector)

+ 6 x (max) Flue extension 1m (pack D)

+ 2 x Flue elbow 45° kit (60/100)

+ Weather collar

211039

6 x 203129

203131

152258/152259*

MAXIMUM

STRAIGHT

FLUE LENGTH

(MM)

6300

NOTE:

* 152258: Weather collar universal 100 dia (suits any roof pitch)

152259: Weather collar flat roof 100 dia

63

64

FLUEING OPTIONS

LOGIC CODE COMBI ES.

POWERED

VERTICAL

FLUE SYSTEM.

FLUE IDEAL

PART NO.

Vertical powered flue kit

+ Flue vertical connector

+ Flue powered vertical terminal 100 dia

+ Weather collar

+ Flue extension 1m (pack D)

+ Flue extension pipe 80 dia (pair)†

203136

208175

203134

152258/152259*

203129

203142

MAXIMUM

STRAIGHT

FLUE LENGTH

(MM)

Primary and

Secondary flue combined maximum

22mm**

NOTE: Allows the boiler to be sited in a position where no access to an outside wall is available. Permits the concentric flue to run vertically from the top of the boiler and obtain air supply within the roof space, the secondary flue continuing to the external flue terminal. Offset applications are permissible though the maximum length is reduced.

* 152258: Weather collar universal 100 dia (suits any roof pitch)

152259: Weather collar flat roof 100 dia

Where extension D packs are cut to length, the flared end connector must be retained.

† Secondary flue extension pipes are available in 0.5, 1 and 2 metre lengths.

** See installation instructions for maximum primary and maximum secondary flue lengths.

Telescopic B pack flue

(0.6m long)

Horizontal flue terminal

(0.6m long)

Telescopic horizontal flue terminal (1m long)

Flue elbow 90° kit (60/100) packaged

Ideal part no.

208169

Flue elbow 45° kit (60/100) packaged (pair)

Ideal part no.

208171

Flue extension

1m (Pack D)

Ideal part no.

208174

Flue vertical connector

Ideal part no.

203130

Flue powered vertical terminal

100 dia

Ideal part no.

203131

Flue deflector

60 dia

Ideal part no.

203129

Weather collar

(universal)

100 dia

Ideal part no.

208175

Weather collar

(flat roof) 100 dia

Ideal part no.

203134

Flue finishing kit

Roof flue kit inc. vertical connector

Vertical

Powered flue kit

Concentric flue screw retaining kit

Flue extension pipe

80 dia (pair) twin/vertical

Ideal part no.

211039

Flue extension

0.5m or 2m

(Pack D)

Ideal part no.

203136

Stand off kit

Ideal part no.

205024

Stand off kit

Inc. piping

Ideal part no.

203142

Condensate pump kit

Ideal part no.

0.5m 211037

2m 211038

DHW expansion vessel kit

Ideal part no.

206383

Pressure gauge extension kit

Ideal part no.

206679

Weather compensation kit

Ideal part no.

159991

Ideal part no.

208176

Ideal part no.

152258

Ideal part no.

152259

Ideal part no.

155988

Ideal part no.

205419

Ideal part no.

206712

Ideal part no.

211326

FLUEING ACCESSORIES

LOGIC CODE COMBI ES.

Telescopic B pack flue

(0.6m long)

Horizontal flue terminal

(0.6m long)

Telescopic horizontal flue terminal (1m long)

Flue elbow 90° kit (60/100) packaged

65

Roof flue kit inc. vertical connector

Vertical

Powered flue kit

Concentric flue screw retaining kit

Flue extension pipe

80 dia (pair) twin/vertical

Ideal part no.

208169

Flue elbow 45° kit (60/100) packaged (pair)

Ideal part no.

208171

Flue extension

1m (Pack D)

Ideal part no.

208174

Flue vertical connector

Ideal part no.

203130

Flue powered vertical terminal

100 dia

Ideal part no.

211039

Flue extension

0.5m or 2m

(Pack D)

Ideal part no.

203136

Stand off kit

Ideal part no.

205024

Stand off kit

Inc. piping

Ideal part no.

203142

Condensate pump kit

Ideal part no.

203131

Flue deflector

60 dia

Ideal part no.

203129

Weather collar

(universal)

100 dia

Ideal part no.

208175

Weather collar

(flat roof) 100 dia

Ideal part no.

203134

Flue finishing kit

Ideal part no.

0.5m 211037

2m 211038

DHW expansion vessel kit

Ideal part no.

206383

Pressure gauge extension kit

Ideal part no.

206679

Weather compensation kit

Ideal part no.

159991

Ideal part no.

208176

Ideal part no.

152258

Ideal part no.

152259

Ideal part no.

155988

Ideal part no.

205419

Ideal part no.

206712

Ideal part no.

211326

Telescopic B pack flue

(0.6m long)

Horizontal flue terminal

(0.6m long)

Telescopic horizontal flue terminal (1m long)

Flue elbow 90° kit (60/100) packaged

66

FLUEING & INSTALLATION ACCESSORIES

LOGIC CODE COMBI ES.

Roof flue kit inc. vertical connector

Vertical

Powered flue kit

Concentric flue screw retaining kit

Flue extension pipe

80 dia (pair) twin/vertical

Ideal part no.

208169

Flue elbow 45° kit (60/100) packaged (pair)

Ideal part no.

208171

Flue extension

1m (Pack D)

Ideal part no.

208174

Flue vertical connector

Ideal part no.

203130

Flue powered vertical terminal

100 dia

Ideal part no.

211039

Flue extension

0.5m or 2m

(Pack D)

Ideal part no.

203136

Stand off kit

Ideal part no.

205024

Stand off kit

Inc. piping

Ideal part no.

203142

Condensate pump kit

Ideal part no.

203131

Flue deflector

60 dia

Ideal part no.

203129

Weather collar

(universal)

100 dia

Ideal part no.

208175

Weather collar

(flat roof) 100 dia

Ideal part no.

203134

Flue finishing kit

Ideal part no.

0.5m 211037

2m 211038

DHW expansion vessel kit

Ideal part no.

206383

Pressure gauge extension kit

Ideal part no.

206679

Weather compensation kit

Ideal part no.

159991

Ideal part no.

208176

Ideal part no.

152258

Ideal part no.

152259

Ideal part no.

155988

Ideal part no.

205419

Ideal part no.

206712

Ideal part no.

211326

INSTALLATION ACCESSORIES

Pre-piping kit

Security fixing kit

INSTALLATION ACCESSORIES

OpenTherm harness kit

PRV wall outlet pipe kit

IDEAL PART NO.

206704

206708

IDEAL PART NO.

204915

205126

Balcony flue outlet kit

Ideal part no. 208177

67

68

FLUEING ACCESSORIES

LOGIC CODE COMBI ES.

Soffit kit

Ideal part no. 211302

Raised horizontal flue outlet kit

NOTE:

A 1 metre vertical pipe is supplied as standard. Both horizontal and vertical lengths can be extended using extension pack D.

Refer to installation instructions for maximum lengths.

Ideal part no. 208290

ACCESSORIES

HIGH LEVEL FLUE OUTLET KIT.

These easy to install kits allow the boiler flue outlet to be extended external to the building, upwards to provide a flue exit at high level, overcoming problems associated with plume emission. The kit can be simply fitted retrofitted if necessary.

An external 60mm diameter flue leads from the boiler terminal (which includes a 90° elbow at the flue exit) to terminate with a 90° elbow complete with grille. Push fit one metre extension pipes are used as required, and the fixing clips supplied support the system from the wall.

Both 90° and 45° elbows are available to provide routing options.

69

THE KIT COMPRISES:

Flue elbow - 1 off

60mm flue exit elbow - 1 off

60mm horizontal flue exit - 1 off

60mm x 500mm flue outlet extension pipe - 1 off

This kit is specified for use with the normal standard B pack.

The standard terminal nose is replaced with the high level terminal.

Diagram representative only.

70

IMPORTANT

Flue must always slope at least 1

1 /

2

˚ back to the boiler

VERTICAL

HORIZONTAL

LEFT OR RIGHT 45˚ LEFT OR RIGHT

LOGIC CODE COMBI ES

High level flue outlet kit

Flue extension kit 60 dia (1m) - for high level flue outlet kit

High level 90° elbow

High level 45° elbow

IDEAL PART NO.

208178

203228

203229

203230

If additional elbows to those supplied in the High

Level Flue Outlet kit are used, deduct the following resistances (metres) from the maximum boiler flue length.

LOGIC CODE COMBI ES

90° elbow

45° elbow (pair)

METRES

1.4

1.25

CONTACT US.

Should you need assistance from any of our specialist teams they are on hand to help you

7 days a week, 364 days a year.

CUSTOMER SERVICE

Tel: 01482 498660

SALES ORDERS AND ENQUIRIES

Tel: 0844 498056

TECHNICAL HELP

Tel: 01482 498663

IDEAL GENUINE PARTS

Tel: 01482 498665

MAIN RECEPTION

Tel: 01482 492251

71

GREAT

BOILERS

FROM

GREAT

BRITAIN.

Ideal Boilers

PO Box 103

National Avenue

Kingston upon Hull

East Yorkshire

HU5 4JN

T 01482 492251

WWW.IDEALBOILERS.COM

02.2016 211153 v5.5

Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement