Below you will find brief information for air purifier Environment Nurse B-757. The air purifier Environment Nurse B-757 is designed for cleaning and purifying air in the home. It uses a combination of HEPA filter, activated carbon filter, ionizer, UV lamp, ozone and possibly an aroma diffuser.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
▼
Scroll to page 2
of
8
UV STERILIZTION AIR PURIFIER INSTRUCTION MANUAL B-757 Series: Environment Nurse Thanks for your selection of our air purifier * Please read the instruction manual carefully before using * Please keep the instruction manual for any future needs Make an ecotypic home to avoid viruses Environment nurse series Environment self cicatrization Produce "air vitamin” e [t can generate 8000000 "air vitamin" every second which can improve the home environment Anti bacteria Restrain the breeding and activity of viruses * The catechol with UV can continuously Kill bacteria and restrain the toxicity of viruses Healthy air e If there is any changes for the parameters, please refer to the machine. Healthy air is the basis of health and life * You will not informed if there is any changes such as the model name, product size : . So iti . h or any other information of the printings. * Achild needs 460KGS of air every day. So it is very important to the * The Design of packing and presswork is for China mainland only. Baren has the right health to improve the air environment of living. for final explanation. Please read the instruction carefully and fully apprehend the cautions to make sure you Cautions 2--3 can operate the product correctly and safely to avoid any hurt. Warning 2 | de th hand ; - t reminds that misusing or mishandling Attention 3 N Warning may cause death Functions 4--5 Purification 4 . . . ps , В . It reminds that misusing or mishandling Technical innovation for purification 4 Attention may cause hurt Technical innovation for humanity 4 Diagram of the ions generator 5 Diagram of the purification system 5 | O FORBID O FORCE Diagram of the product 6 Diagram of the outlook 6 Diagram of the operating parts 6 Diagram of the unit 6 A WA R X | À e Cautions before using 7 Cautions of the working environment 7 Installation of the filters 7 No disassembly, Do plug the power Never Se ihe over Installation of the aroma 7 CE ME ee wiring connector. reconstruction. completely. Do use the rated Power connecting 7 NO DISASSEMBLY FORBID voltage. Disassembly and installation of the filter cover 7 It may cause fire because of = It may cause fire or damage. heating or electric shocking. Instruction manual 8--9 Please send for repairing to Do not use the damaged plug It may cause fire. the retailer. or loosed socket. Power settings 8 Mode and timer settings 8 . . i Never connect Diagram of remote operatin 8 Do Clean The Never insert any U g | р 9 о Plug termly metal objects into ON x or disconnect Fan speed settings 9 the unit. the power with Function settings 9 FORBID avo wer Wet hand. If there is dust on the plug, it Maintain and Cleaning instruction 10 may weaker Ihe insulation, It may cause electric shocking Cautions for cleaning the carbon fibre of ions generator -------------------- 10 Tak e ol dol . e Take out the plug and clean i Cautions for the replacement of the UV lamp 10 it with dry. о It may cause he Soon © Please remove the plug from hurt or electric cleaning, FAQ 11 the socket if not using for a shocking. ong period. DISCONNECT POWER Technical parameters 12 Otherwise the unit may star working in a sudden which may cause Technical parameters of the unit 12 electric shocking or hurt. Technical ¢ £ the UV 19 Do not repair it when the cord or ec nica parameters o e plug is damaged. ` Avoid any water Technical parameters of the HEPA 12 FORBID IN) on the surface Technical parameters of the activated carbon filter 12 x of the unit. It may cause short circuit,electric shocking or fire. AVOID WET © Please send it for repairing to the retailer. It may cause short circuit or electric shocking B-757 + 1 >» * 2 « B-757 4\ ATTENTION р |] ——l]]o ]];;—]—;—]——]—————] FUNCTION Never use in the watery or high temperatured room such as the bathroom etc. AVOID USING IN THE MEX WATERY ROOM с ~~ Otherwise it may cause Die creepage electric shocking or fire. Never use in the room with lampblack such as kitchen. — FORBID It may cause hurt because the machine is not a ventilator Please ventilate timely when used with fire in the room. Otherwise it may cause <= poisoning of CO for the machine is not a ventilator. Don't let the unit working when using insecticide in the room. FORBID Otherwise the insecticide may be stored in the unit and will blow out during the normal working time. It is harmful to your health. ® Please ventilate completely after having used the insecticide before turn on the unit. AVOID FIRE Never blow in any combustible or fired cigarette into the unit. It may cause fire. © Keep away from alcohol, organic impregnant or insecticide. FORBID It may cause cracking, short circuit, electric shocking, hurt or fire. Please hold the plug instead of the cord when unplug the power. Otherwise It may cause short circuit, breaking of the cord, electric shocking or fire. Attention Please remove the plug from the socket if any conditions as below: ® If all switches do not work. ® If the plug or plug hot singularly. ® |f any peculiar smell, exceptional noise or vibration. e Any other abnormity or failure. If the power cord is damaged, please send to the retailer or service center or technician for repairing. Do not change or repair it by yourself. B-757 © Purification lon: More than 8 million ions are generated per second gives you a fresh environment at home. Ozone (optional): It generates around 50mg ozone per hour removing the organic odor effectively and increasing the quantity of oxygen in the air. UV light: The sterilization rate is more than 97.6% HEPA: Absorbs particulate down to 0.0001 mm like pollen, drifting dust and germs with purification efficiency of more than 99.999%. Photo Catalyst: Restrain the activation of the virus effectively. Activated carbon: Catalyze and decompose the harmful gas like formaldehyde, H2S, NH3 efficiently. Aroma drifting (optional): There is a solid aroma box to emit fresh and natural floral perfume. Technical innovation Washable ions generator: There are 4 carbon fibre heads to generate ions and can be cleaned easily. So it ensures the high density of ions being generated continuously. UV anti - bacteria technology: Adopts the characters for killing bacteria of UV, and combines the structure of the unit for air filtration, it can Kill the bacteria in the flowing air effectively. HEPA filter: It is made of the new PP raw material and static fibreglass with the theine distillate which can restrain the allergen and bacteria on the filter. Photo catalyst: The semiconductor of TiO, which can oxygen the red cell of the bacteria and restrain the activity of the viruses is the main material of the photo catalyst. Activated carbon: Itis biosynthesized from the walnut shell. The adsorption area of the activated carbon in the unit is more than 300000 square meters. Humanistic technology Auto mode: Itis controlled by the in-built Samsung IC to set MANUAL/AUTO/TIMER mode according to your need. Auto alarm: There is UV replacement alarm & LED. Safety switch: The unit will power off automatically when the filter cover is opened. LED color screen: The LED color screen with digital technology makes the unit more beautiful. * 4 e B-757 Diagram of the ion generator lon exit Diagram of the purification system © HEPA O UV light O Activated carbon B-757 © Be DIAGRAM OF THE PRODUCT Diagram of the outlook Back cover Deck LED screen Air exit Buttons Air in Front cover —Front cover Side cover | Front view Left view Right view Diagram of the operating parts Ozone, Anion, UV Function ' E a Power Diagram of LED Diagram of operating buttons color screen Fan speed Mode, Timer Diagram of the unit O Leftcover @ Aromacase © Theunit @ Activated carbon O UV light O HEPA O Right cover * 6 + B-757 CAUTIONS BEFORE USING Cautions of the working environment - Keep the unit 30cm or more away from the wall or furniture. - Keep the unit 100cm or more away from the TV or computer. Installation of the filters - Take off the right cover - Take out the HEPA and activated carbon filters, tear off the protectivn bag and put them back into the unit. | Take off the right cover Install the HEPA filter Install the Activated carbon filter Installation of the aroma (1) Take off the left cover (2) Take off the covers of the aroma Power connecting Remark: (1) make sure connecting the unit with the rated power. (2) Please connect the plug with the socket completely. Do connect the plug Do use . the rated with the voltage socke completely Disassembly and installation of the covers *Diagram of disassembly - Lift up the unit with one hand {7 and open the cover with the other hand by holding up from the bottom of the cover *Diagram of installation * Put the top of the cover to the holder of the unit. * Push the downside of the cover. Diagram of disassembly Diagram of installation B-757 7. INSTRUCTION MANUAL Power settings - Press the POWER button on the unit or the remote controller, the unit starts to work and the LED color screen displays: Anion > a [ей ея = yy E] Fan speed Manual mode Mode and timer settings - Press the MODE button successively to select MANU/AUTO/1H/2H/4H function. LED shows: (1) MANU: The unit needs to turn off manually. (2) AUTO: The unit is set to alternate in 20 minutes on 40 minutes off cycles (3) 1H: The unit will stop working after 1 hour. (4) 2H: The unit will stop working after 2 hours. (5) 4H: The unit will stop working after 4 hours. 1.MANU 2.AUTO 3.1H 42H 5.4H Diagram of remote operating POWER C ANION MODE Remark: (1) If the unit can not be controlled by the remote controller sometimes, it may have to replace the battery. uv OZONE SPEED Remote controller panel «8 «+ B-757 Fan speed settings - Press the SPEED button to select low, medium, high fan speed. LED shows: NN 2% =r te == г A EVAL RL BLS A [| i's Bl “ 1 I LP = (e) ¥ ni Medium Function settings - Press the "FUNCTION" button successively to select one or two functions between "ANION" and "OZONE". The diagram is as below: [> Lamon] = ozone | ==> | ANION & OZONE |= [none |= - Press the "UV" button successively to turn on or turn off UV functions. The diagram is as below: - Remark: (1) Ozone is the optional function of the unit. (2) If the ozone function is on, it will be switch to anion automatically after one hour working. (3) HEPA and activated carbon are the initial functions of the unit, it is always working whenever you turn on the unit. B-757 © 9... MAINTAIN AND CLEANING INSTRUCTION Maintain and cleaning instruction © - Do not clean the unit with water. - If clean with scour, please dilute the scour before using. * Do not clean the unit with the solvent listed on the right which may cause distortion or depigmentation. - |f clean with chemical solvent, please read its cautions carefully before using. Please remove the plug from the socket before cleaning and maintain Cautions for cleaning the carbon fibre of ions generator - Open the cover and clean the carbon fibre head with a soft brush. Then close the cover. - Clean it once every month. - Do not put any metal materials to the carbon fibre head even when the power is off because there is still a small quantity of high voltage power. Se Open the left cover Clean the heads Install the cover Cautions for the replacement of the UV lamp * When the symbol of UV is flashing, it reminds you to replace the UV lamp. Diagram of disassembly - Take off the right cover and take out the HEPA filter. * Hold the UV lamp and rotate it for 90° clockwise or anticlockwise, then take it out. Take out the cover Disassembly the and the HEPA UV lamp Diagram of installation - Install the UV lamp in the same way after connect it with its heads. Install the UV lamp Install the cover «10 B-757 FAQ TECHNICAL PARAMETERS Please kindly check as blow before you send out for repairing. Technical parameters of the unit Description UV sterilization air purifier (Environment nurse) Model B-757 | Abnormality | | Inspect Items ) Fan speed LOW MEDIUM HIGH - Check if the plug has disconnected from the socket Air flow volume(m?®/h) 150 200 230 => Connect the power again Do not work - Check if the side cover is installed completely Noise level(db) 25 32 40 => Recover the side cover carefully Power rating(W) 39 39 42 lons 8X10 ions/cm° Continously working - It may because of the IC interfered by environment. Length of power cord 25m and can not stop. — Unplug the power and restart the unit after 15 minutes later. Product size 305X330X170 (mm) Net weight 4 KG - The activated carbon filter or the unit may be polluted. Voltage suppl 220-240V 50Hz| Applicable area 325ft* (301m) Odor can not be => Clean the activated carbon filter or the unit. 9° SUPPTY PP Or replace with a new activated carbon filter. Technical parameters of the UV The dirt in the air : can not be removed - The HEPA filter may be polluted Description | Size patin) vo age working nave Longevity and it works in high > Clean the HEPA filter or replace with a new one. 9 РРУ 9 9 noise . Light 15 | 6w 220V |220V~240V | 254nm 8000 h - The dirt may not be absorbed to the filters Technical parameters of the HEPA с start к > Move to another room to work continously under an not start to wor high fan speed pie Ai ai ir в Purification| Mini size when the airis polluted + The room size may be too large to the applicable area Description Size rate of purification Longevity > Move to another smaller room similar to the licabl applicable area HEPA | 220X100X40 (mm)| =99.9% | <0.0001mm | Approx 1 year Technical parameters of the activated carbon filter If the problem is still exist after the above inspection, please disconnect Description Size Haw a Purification] Longevity the power and send for repairing. materia area аспматес or 220X100X10(mm) | Walnut shell| 300000m? | Approx 6 months B-757 «11. 12 ° B-757
advertisement
Key Features
- HEPA filter
- activated carbon filter
- ionizer
- UV lamp
- Ozone
- Aroma diffuser
Frequently Answers and Questions
What is the function of the HEPA filter?
The HEPA filter is designed to absorb particulate down to 0.0001 mm like pollen, drifting dust and germs with purification efficiency of more than 99.999%.
What is the function of the activated carbon filter?
The activated carbon filter catalyzes and decomposes harmful gases like formaldehyde, H2S, NH3 efficiently.
How often do I need to clean the carbon fiber of the ion generator?
It is recommended to clean the carbon fiber heads with a soft brush once a month.
When should I replace the UV lamp?
When the symbol of UV is flashing, it reminds you to replace the UV lamp.