SCS CTM051 Ground Pro Ground Integrity Meter User Guide

SCS CTM051 Ground Pro Ground Integrity Meter User Guide

Below you will find brief information for Ground Pro Ground Integrity Meter CTM051 Ground Pro Ground Integrity Meter. This device measures ground impedance and high-frequency noise (EMI) on a ground, helping you to identify potential problems with your equipment's ground connection. It can also measure AC and DC voltage on the ground.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Ground Pro Ground Integrity Meter CTM051 User Guide | Manualzz

USER GUIDE TB-9024

Ground Pro Ground Integrity Meter

Installation, Operation and Maintenance

Made in the

United States of America

Controls and Indicators

P o w e r

C

– Turns the power on and off. Hold for a few

seconds to turn the unit off. Also resets some

parameters.

E M I

– Switches the unit into impedance measurement

mode.

– Switches the unit into high-frequency noise

(EMI) measurement mode.

Figure 1. SCS CTM051 Ground Pro Ground Integrity

Meter

V

R e f .

H o l d

– Switches the unit into AC and DC voltage

mode.

– Sets up the reference for measurements and

alarms.

– Freezes the display/and shows the maximum

measured value.

– Adjusts the scale for some parameters and

adjusts reference values.

Description

The SCS CTM051 Ground Pro Ground Integrity Meter is a comprehensive instrument that measures the ground connection of your equipment in accordance with ANSI

6.1 and ANSI/ESDA S.20.20 standards. In addition to measuring ground impedance, it also measures AC and

DC voltage on the ground as well as the presence of high-frequency noise or electromagnetic interference

(EMI) on the ground, alerting you to possible functionality problems, such as tool lockups, erratic behavior and parametric errors.

The Ground Pro Meter is available in one model:

– Display backlight on/off

Features and Components

Banana

Jacks

Item Description

CTM051 Ground Pro Ground Intergrity Meter, with

9V battery and pair probe leads

The following accessory is available for the Ground Pro

Meter:

Item Description

NCA006 Replacement Test Leads

Keypad

Display

Battery

Compartment

(On the back)

Packaging

1 Ground Pro Ground Integrity Meter

1 Pair of probe leads

1 9V battery

1 Certificate of Calibration

Figure 2. CTM051 Ground Pro Ground Integrity Meter components.

TB-9024 Page 1 of 7 October 2015

SCS - 926 JR Industrial Drive, Sanford, NC 27332 • (919) 718-0000 • Website: StaticControl.com

© 2015 DESCO INDUSTRIES, INC.

Employee Owned

Power

The SCS Ground Pro Ground Integrity Meter uses a 9V alkaline battery. Do not use any other battery. If you are not using your Ground Pro Ground Integrity Meter for an extended period of time, remove the battery from the unit in order to prevent damage caused by a possible battery leakage.

Installing the Battery

Remove the screw from the battery lid. Slide off the battery lid at the back of the Ground Pro Ground Integrity

Meter and attach the 9V battery to the battery clip.

Observe the polarity of the battery. Slide in the battery lid and secure it back with the screw.

Low-Battery Indicator

When battery voltage gets low (less than 20% capacity remains), the low battery indicator on the display appears. At this point, replace the battery.

Automatic Power Off

Figure 4. Automatic power on/off indicator.

In order to save battery life, the SCS Ground Pro Ground

Integrity Meter has an automatic power-off (APO) feature that will turn the unit off after approximately 10 minutes if no buttons are pressed. You can access the APO setting by depressing the F button once. You will see the display as shown above. You can then enable or disable

APO using the Up and Down arrow buttons. Please keep in mind that with APO disabled, the battery life will be shorter.

Checking the Battery Voltage

F

0 2 4 6

Figure 3. Low-battery indication.

Turning Unit On and Off

ON

Press the button. If the battery voltage is too low even to indicate low-voltage status on the display or if the self-diagnostic fails, you will hear a beep and the unit will shut itself off. If the battery is completely drained, there may not even be a beep. Please replace the battery. Use proper disposal method per local regulatory requirements.

P o w e r

C

E M I

V

OFF

Press the Power/C button for at least two seconds. The Ground Pro Ground Integrity Meter will turn off.

H o l d

V

%

0 2 Lin 4 6

Figure 5. Battery voltage and percentage.

Press the F button two times to get the screen in Figure

5. The upper display shows the battery voltage, and the lower display shows the percentage of usable battery life left.

TB-9024 Page 2 of 7

SCS - 926 JR Industrial Drive, Sanford, NC 27332 • (919) 718-0000 • Website: StaticControl.com

© 2015 DESCO INDUSTRIES, INC.

Employee Owned

P o w e r

C

Impedance Measurements

0 2 4

Figure 6. Impedance Screen.

E M I

V

R e f .

H o l d

Press the Ohm button to go to ground impedance mode.

You should see a screen similar to the one shown in

Figure 6. The impedance mode is indicated by “OH” on the bottom display line.

Scaling

Ground Pro Ground Integrity Meter will return to normal measurement mode. Now when the test leads are shorted together, the display should show zero Ohms, even though the test leads may have some impedance.

The correction factor will be saved in the internal memory.

If the test leads are not shorted properly or become accidentally disconnected during this process, autozero will fail and you should hear a long beep before the display returns to the impedance measurement screen.

In this case you will need to repeat this process again.

Voltage on Ground Measurements

Do not use to measure mains voltage.

V

The presence of voltage on a ground is never desirable.

The Ground Pro Ground Integrity Meter can measure both AC and DC voltages on a ground.

AC Voltage

Integrity Meter will switch to AC voltage measurement mode and you should see a screen similar to one in

Figure 9. You can adjust the measurement scale using the Up and Down arrow buttons.

Figure 7. Changing the measurement scale

The SCS Ground Pro Ground Integrity Meter has four different scales for measuring ground impedance.

Choose the appropriate scale for your measurements using the Up and Down arrow buttons.

Auto-Zeroing Test Leads

F

0 2 4 6

Figure 8. Test leads screen.

Test leads offer added impedance and may alter measurement results, especially at a lower scale. In order to take impedance of test leads into account, short the ends of the test leads together and press the Function button (F) until you see the screen shown in Figure 8. In a few seconds, this screen will disappear and you will hear a short beep. The SCS

0 2 4 6

Figure 9. AC voltage display

DC Voltage

Press the V button again to switch to DC voltage measurement mode. You should see a screen similar to the one in Figure 10. As in AC mode, you can adjust the measurement scale using the Up and Down arrow buttons.

Overload

If voltage on the ground is above the maximum level on a particular scale, you should see an overload indicator such as the one in Figure 10. In such a case, go to the next scale using the Up arrow button.

SCS - 926 JR Industrial Drive, Sanford, NC 27332 • (919) 718-0000 • Website: StaticControl.com

TB-9024 Page 3 of 7 © 2015 DESCO INDUSTRIES, INC.

Employee Owned

EMI Measurements

EMI

0 2 4

AVG PEAK

V

V

Peak EMI in V

Average EMI in V

Relative peak value

0 2 4 6 8 1 0

Figure 10. AC voltage screen.

0 2

AVG PEAK dB

µ V Peak EMI in dBuV

Average EMI in dBu V

Relative peak value

Using Reference with Impedance

Measurements

0 2

O hms

4

R ef

6 8 10

Normal measurements screen

4

Figure 12. EMI Measurement screen.

High frequency noise (EMI) on a ground causes equipment malfunction and damage to sensitive components. The SCS Ground Pro Ground Integrity

Meter measures high-frequency noise on a ground in a wide frequency and dynamic range.

High-frequency noise is measured in two different units

— volts and dBµV. The latter is a logarithmic measure of voltage where 0 dBµV is referenced to 1 µV.

In order to measure EMI on a ground, press the EMI button. The screen will show the average value of the high-frequency signal in Volts on the bottom display line and the magnitude of the envelope peak of the signal

(i.e. transients or spikes) on the top line. By pressing the

EMI button one more time you can switch to dBµV units, as shown above.

REF Impedance in Ohms

Threshold

4 6 8 10

Figure 11. Impedance measurements screen.

The Reference function helps to set limits at which an audio alarm sounds to indicate that the measured impedance is below the specified limit. Unlike a regular multi meter, the SCS Ground Pro Ground Integrity

Meter allows you to specify an exact impedance value at which the instrument will provide an audio indication.

In Impedance mode, press the Ref. button. You should see a screen similar to the one in Figure 11 with the

REF indicator on. The top line of the display shows the current impedance value (in this example it is an open circuit) and the bottom line shows the reference level.

Adjust the reference level by using the Up and down arrow buttons. Now when the impedance is below the reference value, you should hear a beep. The reference value is set for a particular range – you may need to readjust it for a different range. The reference value will be saved in the internal memory.

Auto Scale

The Ground Pro Ground Integrity Meter uses auto scaling in EMI mode. No scale switching is necessary.

SCS - 926 JR Industrial Drive, Sanford, NC 27332 • (919) 718-0000 • Website: StaticControl.com

TB-9024 Page 4 of 7 © 2015 DESCO INDUSTRIES, INC.

Employee Owned

Using Reference with EMI

Reference mode is helpful if you wish to hear an audio alarm whenever the EMI signal exceeds a certain level.

In order to use this mode, depress the REF button while in any of the EMI screens. You should see the REF indicator at the top of the display. The bottom line of the display will now show the reference value of the peak signal. Adjust the reference level using the Up and Down arrow buttons. Now whenever the peak value of the EMI signal exceeds this reference level, an audio alarm will sound.

Figure 13. Reference mode with EMI.

By pressing the REF button again, you can adjust the reference level for the average signal as shown above.

Hold Function

Pressing the Hold button once while in any measurement mode will cause the SCS Ground Pro Ground Integrity

Meter to enter the Hold mode. The display will freeze, showing the value at the moment the button was pressed.

Pressing the Hold button a second time the display will show the maximum value of the signal accumulated from the moment of pressing the button.

Note: If you power down the Ground Pro Ground Integrity

Meter while in any of these modes, it will remain in the same mode when the unit is powered up again.

Pressing the Hold button one more time puts the Ground

Pro back into regular mode.

Maintenance

Clean using a dry brush or vacuum cleaner around the device. In case of contact malfunction, clean contacts using a contact cleaner or a brush and tighten all connections.

Repairs and Servicing

Do not attempt to repair the product yourself. Contact a

SCS sales representative or authorized dealer to request inspection and repair. There are no user-serviceable parts.

Device Calibration

Contact a SCS sales representative or authorized dealer to request for product calibration if needed.

Specifications

Power

Battery 9V Alkaline

Impedance

Range 0.000 to 1.999 Ohm, 2% + 0.003 Ohm

00.00 to 19.99 Ohm, 1% + 0.05 Ohm

000.0 to 199.9 Ohm, 1% + 0.5 Ohm

0000 to 1999 Ohm, 1% + 5 Ohm

Automatic auto-zero for test leads

EMI (noise on ground)

Bandwidth 9kHZ to 450MHz

Measurement

Range

10mV to 5Vpeak

80dBµV to 134dBµV

Measuremnt Type Average

Peak

Voltage on Ground

AC (50 to 500 Hz) 0.001 to 10V RMS

0.001 to 10V DC

General

Dimensions

(approx)

Weight (approx)

4.5ʺ x 2.4ʺ x 1.1ʺ

(114 mm x 60 mm x 28 mm)

.3 lbs (.14 kg)

Figure 14. Hold mode.

SCS - 926 JR Industrial Drive, Sanford, NC 27332 • (919) 718-0000 • Website: StaticControl.com

TB-9024 Page 5 of 7 © 2015 DESCO INDUSTRIES, INC.

Employee Owned

Safety Information

Intended Use

The Ground Pro Ground Integrity Meter measures several important parameters of grounding: ground impedance and high-frequency noise (EMI) on a ground.

This device is not intended to be used to measure mains voltage.

It is necessary to use proper equipment to check for stray voltage from mains prior to using the Ground Pro

Ground Integrity Meter to measure ground.

to SCS for service.

• Do not use the Meter or test leads outside of the operating conditions listed in this user guide.

• Keep fingers behind the finger guards on the leads.

• All personnel using this device shall be certified or properly trained.

Caution: To reduce the risks associated with environmental contamination:

Dispose of meter and all components in accordance with all applicable local and government

Notice: To reduce the risks associated with property damage:

• Before use, check that the meter is functioning

correctly.

• Remove battery before long-term storage

Ground connectivity is measured in accordance with

ANSI 6.1. It is measured as impedance in a way that is immune to parasitic signals on a ground. In addition to monitoring the ground connection, the Ground Pro measures high frequency noise (EMI) on the ground that is often present in a factory environment. Such interference causes problems with the operation of equipment.

The device must be used as specified in this user guide in an indoor commercial/industrial environment, and has not been evaluated for other uses or locations. If the equipment is used in a manner not specifi ed by the manufacturer, the protection provided by the equipment may be impaired.

Read, understand, and follow all safety information contained in these instructions prior to the use of this device. Retain these instructions for future reference.

Warning: To reduce the risks associated with fire and explosion:

• Do not use in Hazardous Locations.

To reduce the risks associated with hazardous voltage and fire:

• Do not use this device outdoors or in wet or humid environments.

• Do not use this device outside of the operating conditions listed in this user manual.

To reduce the risks associated with hazardous voltage:

• Do not replace battery while device is in use.

Battery compartment is only intended to be open with the device powered off.

• Do not operate if the battery door is not in place.

• Do not use meter to test three-phase equipment.

• Do not use to measure mains voltage Disconnect circuit power and discharge all high-voltage capacitors before testing resistance, continuity, diodes, or capacitance.

• Always use proper terminals and device settings.

• Check the test leads for continuity before use. Do not use if the readings are high or noisy.

• Do not use the meter or test leads if damaged or are not operating properly.

• Do not modify or attempt to service the meter or leads; there are no user serviceable parts. Return

Environmental Conditions

This equipment has been tested and found to be safe to operate within these environmental conditions.

This is not a warranty of equipment performance within these conditions:

• Indoor use only.

• Ingress Protection: IPX0.

• Altitude: Up to 2,000 m.

• Pollution degree 2.

• Temperature: Maximum 110°F / 43°C

Minimum 50°F / 10°C

• Humidity: Maximum relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C

Regulatory Information

China RoHS

Electronic Industry Standard of the People’s Republic of

China, SJ T11363-2006, Requirements for Concentration

Limits for Certain Hazardous Substances in Electronic

Information Products

This symbol, per Marking for the

Control of Pollution Caused by

Electronic Information Products, SJ/

T11364-2006, means that the product or part does contain a substance, as detailed in the chart below, in excess of the following maximum concentration values in any homogeneous material: (a) 0.1% (by weight) for lead, mercury, hexavalent chromium, polybrominated biphenyls or polybrominated diphenyl ethers; or (b) 0.01% (by weight) for cadmium. Unless otherwise stated by SCS in writing, this information represents SCS best knowledge and belief based upon information provided by third party suppliers to SCS.

SCS - 926 JR Industrial Drive, Sanford, NC 27332 • (919) 718-0000 • Website: StaticControl.com

TB-9024 Page 6 of 7 © 2015 DESCO INDUSTRIES, INC.

Employee Owned

Part or Component Name

Termination in capacitor 0603

Solder in diode

Finish in diode

Terminations in PCBs

Terminations in resistors 0603

(Pb)

X

X

X

X

X

Hazardous Substances or Elements

(Hg)

O

O

O

O

O

(Cd)

O

O

O

O

O

(CrVI)

O

O

O

O

O

(PBB)

O

O

O

O

O

(PBDE)

O

O

O

O

O

Plating in resistors 0603

Resistor ink in potentiometer

Solder in instrument

Solder in IC

X

X

X

X

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

Solder in buzzer X O O O O O

Audio jack X O O O O O

O: Indicates that this hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in the SJ/T11363-2006.

X: Indicates that this hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in the SJ/T11363-2006.

This numerical reference should not be construed as a representation regarding the product’s life or an extension of a product warranty. In the event any product is proven not to conform with SCS’s Regulatory Information Sheet, then SCS’s entire liability and buyer’s exclusive remedy, will be at SCS’s option either: (i) replacement of product with a conforming product, or (ii) refund of the purchase price paid by buyer for each nonconforming product, within a reasonable time after written notifi cation of said nonconformance and return of said product to SCS. SCS shall not under any circumstances be liable for direct, incidental, special, or consequential damages (including but not limited to loss of profits, revenue, or business) related to or arising out of this certifi cation, including, the use, misuse or inability to use the product. Unless stated otherwise in writing, the foregoing language cannot be waived, modifi ed, or supplemented in any manner whatsoever.

This is the EU symbol for equipment that is covered under the Waste from Electrical and Electronic Equipment

(WEEE) directive per CENELEC Specifi cation 5041. It indicates that certain products should not be discarded in the trash, but rather should be recycled. This applies to all electronic pluggable and battery powered products.

FCC

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part

15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

INDUSTRY CANADA

This Class A digital apparatus complies with Canadian

ICES-003.

Cet appareil numérique de la classe A est conforme á la

NMB-003 du Canada.

Limited Warranty, Warranty Exclusions, Limit of

Liability and RMA Request Instructions

See the SCS Warranty - http://staticcontrol.descoindustries.com/warranty.aspx

SCS - 926 JR Industrial Drive, Sanford, NC 27332 • (919) 718-0000 • Website: StaticControl.com

TB-9024 Page 7 of 7 © 2015 DESCO INDUSTRIES, INC.

Employee Owned

advertisement

Key Features

  • Measures ground impedance
  • Measures high-frequency noise (EMI)
  • Measures AC and DC voltage on the ground
  • Auto-zeroing test leads for accurate measurements
  • Adjustable reference levels for alarms
  • Hold function to freeze the display
  • Automatic power-off to save battery life
  • Low-battery indicator to warn you when the battery is low

Frequently Answers and Questions

How do I auto-zero the test leads?
Short the ends of the test leads together and press the Function button (F) until you see the screen shown in Figure 8. In a few seconds, this screen will disappear and you will hear a short beep. The Ground Pro Ground Integrity Meter will return to normal measurement mode.
How do I adjust the reference level for impedance measurements?
In Impedance mode, press the Ref. button. The top line of the display shows the current impedance value (in this example it is an open circuit) and the bottom line shows the reference level. Adjust the reference level by using the Up and down arrow buttons. Now when the impedance is below the reference value, you should hear a beep.
How do I use the Hold function?
Pressing the Hold button once while in any measurement mode will cause the Ground Pro Ground Integrity Meter to enter the Hold mode. The display will freeze, showing the value at the moment the button was pressed. Pressing the Hold button a second time the display will show the maximum value of the signal accumulated from the moment of pressing the button.

Related manuals

Download PDF

advertisement