Shenzhen Toby Technology Co., Ltd. LVD Test Report

Shenzhen Toby Technology Co., Ltd. LVD Test Report
Shenzhen Toby Technology Co., Ltd.
Report No.: TB-LVD146103
Page:
1 of 44
LVD Test Report
Application No.
:
TB151111534
Applicant
:
CCTV Technologies PTE. LTD.
Equipment Under Test (EUT)
EUT Name
:
ADVR
Model No.
:
PB7804R-LM(HDMI)
Serial No.
:
See the Model list of page 5
Brand Name
:
CCTVTECH
Issue Date
:
2015-11-30
Standards
:
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 +
A12:2011 and/or
IEC 60065:2001 (Seventh Edition) + A1:2005 +A2:2010
Conclusions
:
Complied
Report by
:
Checked by
:
Approved by
:
This test report is valid for above tested sample only and shall not be reproduced in part
without written approval of the laboratory.
TB-RF-076-3.0
1A/F.,Bldg.6, Yusheng Industrial Zone,The National Road No.107 Xixiang Section 467,Xixiang,
Bao'an Shenzhen,Guangdong,China
Tel: +86 75526509301 Fax: +86 75526509195
Report No.: TB-LVD146103
Page:
2 of 44
TEST REPORT
IEC/EN 60065
Audio, video and similar electronic apparatus - Safety requirements
Report Number. ........................... :
TB-LVD146103
Total number of pages ...................
44 Pages
Testing Laboratory ...................... :
Shenzhen Toby Technology Co., Ltd.
Address ......................................... : 1A/F.,Bldg.6, Yusheng Industrial Zone,The National Road No.107
Xixiang Section 467,Xixiang,Bao'an Shenzhen,Guangdong,China
Applicant’s name ......................... : CCTV Technologies PTE. LTD.
Address ......................................... :
Yishun, Industrial Street 1 North Point Bizhub, Singapore 768159
Manufacturer’s name…………….:
CCTV Technologies PTE. LTD.
Address ......................................... :
Yishun, Industrial Street 1 North Point Bizhub, Singapore 768159
Test specification:
Standard ........................................ :
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
and/or
IEC 60065:2001 (Seventh Edition) + A1:2005 +A2:2010
Procedure deviation ...................... :
N/A
Non-standard test method…………: N/A
Test Report Form No. .................. :
IEC/EN60065
Test Report Form(s) Originator .....:
TOBY
Master TRF ................................... :
Dated 2012-02
Test item description ................. :
Trade Mark .................................... :
ADVR
CCTVTECH
Manufacturer ................................. :
CCTV Technologies PTE. LTD.
Models/Type reference .................. : PB7804R-LM(HDMI) (see the Model list of page 5)
Ratings .......................................... : DC12V, 4A
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
3 of 44
Copy of marking plate :
CCTVTECH
Name: ADVR
Model : PB7804R-LM(HDMI)
Rating: DC12V, 4A
CCTV Technologies PTE. LTD.
Made In China
Remark:
The marking plates of the other models are of the same pattern.
The above label is draft of the artwork for marking plate pending approval by National Certification Bodies and
they shall not be affixed to products prior to such approvals.
Summary of testing:
Tests performed (name of test and test clause):
The sample(s) tested complies with the requirements of IEC/EN 60065
These tests fulfil the requirements of standard ISO/IEC 17025.
When determining the test conclusion, the Measurement Uncertainty of test has been considered.
Heating test (7.1):
Tma = 25 C (Defaulted without declared by manufacturer)
Tamb = 24.5 C – 25.8C
K-type thermocouple used for temperature measurement.
Summary of compliance with National Differences
Compliance with the National requirements of CENELEC common modification.
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
4 of 44
Test item particulars ............................................. :
Equipment mobility ............................................... : Movable
Connection to the mains ....................................... : Directly connected to the mains
Operating condition .............................................. : continuous
Class of equipment .............................................. : SELV
IP protection class ............................................... : IPX0
Mass of equipment (kg) ....................................... : Approx. 1.45kg
Possible test case verdicts:
- test case does not apply to the test object ............ : N/A
- test object does meet the requirement .................. : P (Pass)
- test object does not meet the requirement ............ : F (Fail)
Testing .................................................................... :
Date of receipt of test item ....................................... : 2015-11-23
Date(s) of performance of tests ............................... : 2015-11-24 to 2015-11-30
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a point is used as the decimal separator.
This document is issued by the company under its General Conditions of Service accessible at
www.tobylab.com. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues
defined therein.
Any holder of this document is advised that information contained hereon reflects the Company’s findings
at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole
responsibility is to its Client and this document does not exonerate parties to a transaction from
exercising all their rights and obligations under the transaction documents. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law.
Unless otherwise stated: (a) the results shown in this document refer only to the sample(s) tested and (b)
such sample(s) are retained for 12 months. This document cannot be reproduced except in full, without
prior approval of the company.
General product information:
ADVR, Powered by a certificated AC adapter with input: 100-240 V~, 50/60 Hz, 1.5A Max.; Output:
12V 4A, for indoor use only.
The product models are identical in the same layout, interior structure and electrical circuits with the
model PB7804R-LM(HDMI) which was considered/chosen as representative to perform all tests in this
report, the differences are the model name, product appearance and color.
Instructions and equipment marking related to safety is applied in the language that is acceptable in the
country in which the equipment is to be sold.
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
5 of 44
Model list:
PB7808R-LM(HDMI), PB7808R-EL(HDMI), PB7804TR-LM, PB7808TR-LM, PB7804T-EL, PB7808T-EL,
PB7816T-EL, PB7804T-LM, PB7004T-LM, PB7008T-LM, PB7016T-LM, PB7004T-MH, PB7008T-MH,
PB7004T-H, PB7004T-H-V2, PB7004T-MH-V2, PB7008T-MH-V2,PB7004B-LM, PB7008B-LM,
PB7016B-LM, PB7004B-MH, PB7004B-MH-V2, PB7004C-LM/A, PB7008C-LM/A, PB7016C-LM/A,
PB7004DA-LM, PB7008DA-LM, PB7016DA-LM, PB7004DA-MH, PB7008DA-MH, PB7016DA-MH,
PB7004DA-MH-V2, PB7008DA-MH-V2, PB7016DA-MH-V2, PB7004DA-H,
PB7008DA-H, PB7004DA-H-V2, PB7016E-M, PB7024E-M, PB7032E-LM, PB7032F-LM, PB7008F-M,
PB7016F-M, PB7024F-M, PB7016F-MH. PB7008F-H, PB7116K-LM, PB7132K-LM, PB7108K-M,
PB7116K-M, PB7124K-M, PB7116K-MH, PB7108K-H
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
6 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
3
General requirements
Safety class of the apparatus ............................. :
Result--Remark
Verdict
P
Powered by SELV
P
4
General test conditions
P
4.1.4
Ventilation instructions require the use of the test box
N
5
Marking and instructions
P
5.1
Comprehensible and easily discernible
All markings are printed on
label pasted on outer
enclosures of the appliance.
P
Permanent durability against water and petroleum
spirit
After rubbing test by water and
petroleum spirit, the markings
are still easily discernible,
indelible and legible.
P
a) Identification, maker ....................................... :
See marking plate in page 2
P
b) Model number or type reference ..................... :
See marking plate in page 2
P
c) Class II symbol if applicable ........................... :
N
d) Nature of supply .............................................. :
P
e) Rated supply voltage ...................................... :
5.2
5.3
5.4
12V
P
f) Mains frequency if safety dependant .............. :
N
g) Rated current or power consumption for apparatus 4A
supplied by supply apparatus for general use .... :
P
Measured current or power consumption ........... :
P
Deviation % (max 10%) ...................................... :
P
h) Rated current or power consumption for apparatus intended for connection to an a.c. mains supply
............................................................................. :
N
Measured current or power consumption ........... :
N
Measured current or power consumption for
Television set ...................................................... :
N
Deviation % (max 10%) ...................................... :
N
a) Earth terminal
N
b) Hazardous live terminals
N
c) Markings on supply output terminals
N
a) Use of triangle with exclamation mark
N
b) marking on loudspeaker grille, IEC 60417-5036
N
Instructions for use
English
P
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
7 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
5.4.1
a) Mains powered equipment not exposed to dripping
or splashing. Warning concerning objects filled with
liquid, etc.
N
b) Hazardous live terminals, instructions for wiring
N
c) Instructions for replacing lithium battery
P
d) Class I earth connection warning
N
e) Instructions for multimedia system connection
N
f) Special stability warning for attachment of the
apparatus to the floor/wall
N
g) Warning: battery exposure to heat
P
h) Warning: protective film on CRT face
N
5.4.2
a-b) Disconnect device: plug/coupler or all-pole
mains switch location, accessibility and markings
Result--Remark
Verdict
DC connector
N
c) Instructions for permanently connected equipment
N
Marking, signal lamps or similar for completely
disconnection from the mains
N
6
Hazardous radiation
N
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
N
Ionizing radiation under fault condition
N
Laser radiation, emission limits to IEC 60825-1:2007
............................................................................. :
N
Emission limits under fault conditions ................ :
N
7
Heating under normal operating conditions
P
7.1
Temperature rises not exceeding specified values;
fuse links and other protective devices defeated
(see appended table)
P
7.1.1
Temperature rise of accessible parts
(see appended table)
P
7.1.2
Temperature rise of parts providing electrical
insulation
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
(see appended table)
P
7.1.4
Temperature rise of windings
(see appended table)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the mains
carrying a current > 0,2 A at least 150 oC
6.2
N
N
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
8 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
8
Constructional requirements with regard to the protection against electric
shock
N
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
N
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
N
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
8.4
No risk of electric shock from accessible parts or from No cover can be removed by
parts rendered accessible following the removal of a hand
cover which can be removed by hand
N
8.5
Class I equipment
N
Basic insulation between hazardous live parts and
earthed accessible parts
N
Resistors bridging basic insulation complying with
14.1 a)
N
Capacitors bridging basic insulation complying with
14.2.1 a)
N
Protective earthing terminal
N
Class II equipment and Class II constructions within
Class I equipment
N
Double or reinforced insulation between hazardous
live parts and accessible parts
N
Components bridging double or reinforced insulation
complying with 14.1 a) or 14.3
N
Basic insulation bridged by components complying
with 14.3.4.3.
N
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.1 a)
N
Double or reinforced insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
N
Double or reinforced insulation being bridged with a
single capacitor complying with 14.2.1 b)
N
8.7
This clause is void
—
8.8
Basic or supplementary insulation > 0,4 mm (mm)
............................................................................ :
N
Reinforced insulation > 0,4 mm (mm) ............... :
N
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
N
8.6
Result--Remark
Verdict
.
N
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
9 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
Result--Remark
Verdict
Basic or supplementary insulation, at least two layers,
each meeting 10.3
N
Basic or supplementary insulation, three layers any
two of which meet 10.3
N
Reinforced insulation, two layers each of which meet
10.3
N
Reinforced insulation, three layers any two which
meet 10.3
N
Adequate insulation between internal hazardous live
conductors and accessible parts
N
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts
N
Double insulation between conductors connected to
the mains and accessible parts.
N
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
N
Detaching of wires
N
No undue reduction of creepages or clearance
distances if wires become detached
N
Vibration test carried out .................................... :
N
8.12
This clause is void
—
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
N
8.14
Adequate fastening of covers (push/pull test 50 N for
10 s)
N
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
N
8.16
Only special supply equipment can be used
P
8.17
Insulated winding wire without additional interleaved
insulation
N
8.18
Endurance test as required by 8.17
N
8.19
Disconnection from the mains
N
8.19.1
Disconnect device
N
All-pole switch or circuit breaker with >3mm contact
separation
N
8.19.2
Mains switch ON indication
P
8.20
Switch not fitted in the mains cord
N
8.21
Bridging components comply with clause 14
N
8.22
Non-separable thin sheet material
N
8.9
8.10
8.11
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
10 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
9
Electric shock hazard under normal operating conditions
N
9.1
Testing on the outside
N
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
N
9.1.1.1
a) Open circuit voltages
N
b) Touch current measured from terminal devices
using the network in annex D ............................ :
N
c) Discharge not exceeding 45 μC
N
d) Energy of discharge not exceeding 350 mJ
N
9.1.1.2
Test with test finger and test probe
N
9.1.2
No hazardous live shafts of knobs, handles or levers
N
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
N
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
N
Terminal devices tested with 1 mm x 100 mm straight
wire (1 N); test probe D of IEC 61032
N
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
N
9.1.6
No shock hazard due to stored charge on withdrawal
of the mains plug; voltage (V) after 2 s .............. :
N
If C is not greater than 0,1 μF no test needed
N
Resistance to external forces
N
a) Test probe 11 of IEC 61032 for 10 s (50 N)
N
b) Test hook of fig. 4 for 10 s (20 N)
N
c) 30 mm diameter test tool for 5 s (100 or 250 N)
N
9.2
No hazard after removing a cover by hand
N
10
Insulation requirements
N
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ............................................................ :
N
10.2
Humidity treatment 48 h or 120 h ...................... :
N
10.3
Insulation resistance and dielectric strength between
mains terminals
N
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class I)
N
9.1.7
Result--Remark
Verdict
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
11 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
Result--Remark
Verdict
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
N
11
Fault conditions
P
11.1
No shock hazard under fault condition
P
11.2
Heating under fault condition
P
Flames extinguish within 10 seconds
No flames
P
No hazard from softening solder
P
Soldered terminations not used as protective
mechanism
P
11.2.1
Measurement of temperature rises
(see appended table)
P
11.2.2
Temperature rise of accessible parts
(see appended table)
P
11.2.3
Temperature rise of parts, other than windings and
printed boards, providing electrical insulation
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
(see appended table)
P
11.2.5
Temperature rise of windings
(see appended table)
P
11.2.6
Temperature rise of printed boards shall not exceed
the limits of table 3 by max. 100 K for max. 5 min
(see appended table)
P
N
Printed circuit boards (PCB) classified as V-0
according to 60695-11-10 or Clause G.1 may exceed
the limit in table 3 in case a) and b):
N
a) Temperature rise of printed circuit boards
exceeding the limits of table 3 by not more than
100 K for an area not greater than 2 cm² ........... :
N
b) Temperature rise of printed circuit boards
exceeding the limits of table 3 up to 300 K for an area
not greater than 2 cm² for a maximum of 5 min
N
Meets all the special conditions if conductors on
printed circuit boards are interrupted
N
Class I protective earthing maintained
N
11.2.7
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.6 shall not exceed the limits in table 3,
item e), "Fault conditions".
N
12
Mechanical strength
N
12.1.1
Bump test where mass >7 kg
N
12.1.2
Vibration test
N
12.1.3
Impact hammer test
N
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
12 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
Result--Remark
Verdict
Steel ball test
N
12.1.4
Drop test for portable apparatus where mass ≤ 7 kg
N
12.1.5
Thermoplastic enclosures stress relief test
N
12.2
Fixing of knobs, push buttons, keys and levers
N
12.3
Remote controls with hazardous live parts
N
12.4
Drawers (pull test 50 N, 10 s)
N
12.5
Antenna coaxial sockets providing isolation
N
12.6
Telescoping or rod antennas construction
N
12.6.1
Telescoping or rod antennas securement
N
13
Clearances and creepage distances
N
13.1
Clearances in accordance with 13.3
N
Creepage distances in accordance with 13.4
N
13.2
Determination of working voltage
N
13.3
Clearances
N
13.3.1
General
N
13.3.2
Circuits conductively connected to the mains comply
with table 8 and, where applicable, table 9 ........ :
N
13.3.3
Circuits not conductively connected to the mains
comply with table 10
N
13.3.4
Measurement of transient voltages
N
13.4
Creepage distances
N
Creepage distances greater than table 11 minimum
values
N
13.5
Printed boards
N
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
N
13.6
Conductive parts along uncemented joints clearances
and creepage distances comply with 13.3 and 13.4
N
Conductive parts along reliably cemented joints
comply with 8.8
N
Temperature cycle test and dielectric strength test
N
500V test for transformers, magnetic coupler and
similar devices, if insulation is relied upon for safety
N
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
13 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
13.7
Enclosed, enveloped or hermetically sealed parts not
conductively connected to the mains, clearances and
creepage distances as in table 12
N
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
N
14
Components
P
14.1
Resistors
N
a) Resistors between hazardous live parts and
accessible metal parts
N
b) Resistors, other than between hazardous live parts
and accessible parts
N
Resistors separately approved .......................... :
N
Capacitors and RC units
N
14.2
Capacitors separately approved
Result--Remark
Verdict
:
N
14.2.1
Y capacitors tested to IEC 60384-14:2005 ........ :
N
14.2.2
X capacitors tested to IEC 60384-14:2005 ........ :
N
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 .................. :
N
14.2.5
Capacitors with volume exceeding 1750 mm³, where
short-circuit current exceeds 0,2 A: compliance with
IEC 60384-1, 4.38 category B or better .............. :
N
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1, 4.38
category B or better ........................................... :
N
Shielded by a barrier acc. to 20.1.4/ table 21 or metal
............................................................................ :
N
Inductors and windings
N
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
N
Transformers and inductors marked with
manufacturer's name and type .......................... :
N
Transformers and inductors separately approved
............................................................................ :
N
General
N
Insulation material complies with clause 20.1.4
N
14.3.3
Constructional requirements
N
14.3.3.1
Clearances and creepage distances comply with
clause 13
N
14.3
14.3.1
14.3.2
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
14 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
14.3.3.2
Transformers meet the constructional requirements
N
14.3.4
Separation between windings
N
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation) ......................... :
N
Coil formers and partition walls > 0,4 mm
N
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of 14.3.4.2
are met
N
14.3.4.3
Separating transformers with at least basic insulation
N
14.3.5
Insulation between HAZARDOUS LIVE parts and
ACCESSIBLE parts
N
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
N
Coil formers and partition walls > 0,4 mm
N
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N
Winding wires connected to protective earth have
adequate current-carrying capacity
N
High voltage components
N
High-voltage components and assemblies: U > 4 kV
(peak) separately approved
N
Component meets category V-1 of IEC 60707
N
14.4.1
High voltage transformers and multipliers tested as
part of the submission
N
14.4.2
High voltage assemblies and other parts tested as
part of the submission
N
14.5
Protective devices
N
Protective devices used within their ratings
N
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
N
a) Thermal cut-outs separately approved
N
b) Thermal cut-outs tested as part of the submission
N
a) Thermal links separately approved
N
b) Thermal links tested as part of the submission
N
14.3.5.2
14.4
14.5.1.1
14.5.1.2
Result--Remark
Verdict
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
15 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
14.5.1.3
Thermal devices re-settable by soldering
N
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
N
14.5.2.2
Correct marking of fuse-links adjacent to holder :
N
14.5.2.3
Not possible to connect fuses in parallel ........... :
N
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ..... :
N
14.5.3
PTC thermistors comply with IEC 60730-1:2007
N
PTC devices (15 W) category V-1 or better
N
14.5.4
Circuit protectors have adequate breaking capacity
and their position is correctly marked
N
14.6
Switches
N
14.6.1 a)
Separate testing to IEC 61058-1 including:
- 10 000 operations
- Normal pollution suitability
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1
N
14.6.1 b)
Tested in the apparatus:
P
Switch controlling > 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1
P
Switch controlling > 0.2A with open contact voltage
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0
in annex G, G.1.1
N
Switch controlling < 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.4 and
V-0 in annex G, G.1.1
N
14.6.2
Switch tested to 14.6.1 b) constructed to IEC 61058-1
subclause 13.1 and has making/breaking action
independent of speed of actuation
N
14.6.3
Switch tested to 14.6.1 b) compliant with IEC 61058-1
subclause 16.2.2 d) and m) not attaining excessive
temperatures in use
N
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
N
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 61058-1
N
Socket outlet current marking correct
N
Safety interlocks
N
Safety interlocks to 2.8 of IEC 60950-1
N
Voltage setting devices and the like
N
14.7
14.8
Result--Remark
Verdict
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
16 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
Result--Remark
Verdict
Voltage setting device not likely to be changed
accidentally
N
14.9
Motors
N
14.9.1
Endurance test on motors
N
Motor start test
N
Dielectric strength test
N
14.9.2
Not adversely affected by oil or grease etc.
N
14.9.3
Protection against moving parts
N
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950-1, Annex B
N
14.10
Batteries
P
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
P
14.10.2
No possibility of recharging non-rechargeable
batteries
14.10.3
Recharging currents and times within manufacturers
limits
N
Lithium batteries discharge and reverse currents
within the manufacturers limits
N
14.10.4
Battery mould stress relief
N
14.10.5
Battery drop test
N
14.11
Optocouplers
N
a) Comply with 13.6 (jointed insulation) and N.2.1
N
b) Comply with IEC 60747-5-5:2007
N
Alternative to a) and b) optocoupler comply with 13.8
N
a) Comply with 13.6 (jointed insulation) and N.2.1
N
Surge suppression varistors
N
Comply with IEC 61051-2
N
Not connected between mains and accessible parts
except for earthed parts of permanently connected
apparatus
N
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
N
Terminals
P
14.12
15
No rechargeable circuit
TB-RF-076-3.0
N
Report No.: TB-LVD146103
Page:
17 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
15.1.1
Mains plug, appliance inlet, interconnection couplers
and mains socket-outlet meet the appropriate
standard
N
Overloading of plugs or appliance inlets prevented if
the apparatus has mains socket outlets
N
Overloading of internal wiring prevented if the
apparatus has mains socket outlets
N
Connectors for antenna, earth, audio, video or
data
P
No risk of insertion in mains socket-outlets
N
No risk of insertion into audio- or video- outlets
marked with the symbol of 5.2
N
15.1.3
Output terminals of a.c. adaptors or similar devices
not compatible with household mains socket-outlets
N
15.2
Provision for protective earthing
N
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within equipment
N
Protective earth conductors correctly coloured
N
Equipment with non-detachable mains cord provided
with separate protective earth terminal near mains
input
N
Protective earth terminal resistant to corrosion
N
Earth resistance test: < 0,1  at 25 A .............. :
N
15.3
Terminals for external flexible cords and for
permanent connection to the mains supply
N
15.3.1
Adequate terminals for connection of permanent
wiring
N
15.3.2
Reliable connection of non-detachable cords
N
Not soldered to conductors of a printed circuit board
N
Adequate clearances and creepage distances
between connections should a wire break away
N
Wire secured by additional means to the
conductor
N
15.3.3
Screws and nuts clamping conductors have adequate
threads: ISO 261, ISO 262 or similar
N
15.3.4
Soldered conductors wrapped around terminal prior
to soldering or held in place by additional means
N
Clamping of conductor and insulation if not soldered
or held by screws
N
15.1.2
Result--Remark
Verdict
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
18 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
15.3.5
Terminals allow connection of appropriate crosssectional area of conductors, for the rated current of
the equipment
N
15.3.6
Terminals to 15.3.3 have sizes required by table 16
N
15.3.7
Terminals clamp conductors between metal and have
adequate pressure
N
Terminals designed to avoid conductor slipping out
when tightened or loosened
N
Terminals adequately fixed to avoid loosening when
the clamping is tightened or loosened and stress on
internal wiring is avoided
N
15.3.8
Terminals carrying a current more than 0,2 A: contact
pressure not transmitted by insulating material except
ceramic
N
15.3.9
Termination of non-detachable cords: wires
terminated near to each other
N
Terminals located and shielded: test with 8 mm
strand
N
15.4
Devices forming a part of the mains plug
N
15.4.1
No undue strain on mains socket-outlets
N
15.4.2
Device complies with standard for dimensions of
mains plugs
N
15.4.3
Device has adequate mechanical strength (tests
a,b,c)
N
16
External flexible cords
N
16.1
Mains cords sheathed type, complying with
IEC 60227 for PVC or IEC 60245 for synthetic rubber
cords .................................................................. :
N
Non-detachable cords for Class I have green/yellow
core for protective earth
N
16.2
Mains cords conductors have adequate crosssectional area for rated current consumption of the
equipment
N
16.3
a) Flexible cords not complying with 16.1, used for
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
N
b) Flexible cords not complying with 16.1, withstand
bending and mechanical stress (3.2 of IEC 60227-2)
N
Result--Remark
Verdict
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
19 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
N
16.5
Adequate strain relief on external flexible cords
N
Not possible to push cord back into equipment
N
Strain relief device unlikely to damage flexible
cord
N
For mains cords of Class I equipment, hazardous live
conductors become taut before earth conductor
N
16.6
Apertures for external flexible cord: no risk of damage
to the cord during assembly or movement in use
N
16.7
Transportable musical instruments and amplifiers
fitted with detachable cord set with appliance inlet to
IEC 60320-1
N
Transportable musical instruments and amplifiers
fitted with detachable cord sets or with means of
stowage to protect the cord
N
17
Electrical connections and mechanical fixings
N
17.1
Torque test to table 20
N
- screws into metal: 5 times
N
- screws into non-metallic material: 10 times
N
17.2
Correct introduction into female threads in nonmetallic material
N
17.3
Cover fixing screws: captive
N
Non-captive fixing screws: no hazard when replaced
by a screw whose length is 10 times its diameter
N
17.4
No loosening of conductive parts carrying a
current > 0,2 A
N
17.5
Contact pressure not transmitted through plastic
other than ceramic for connections carrying a
current > 0,2 A
N
17.6
Stranded conductors of flexible supply cords carrying
a current > 0,2 A with screw terminals not
consolidated by solder
N
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous
N
17.8
Fixing devices for detachable legs or stands
provided
N
Result--Remark
Verdict
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
20 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
17.9
Internal pluggable connections, affecting safety,
unlikely to become disconnected
N
18
Mechanical strength of picture tubes and protection against the effects of
implosion
N
18.1
Picture tube separately approved to IEC 61965 :
N
Picture tube separately approved to 18.2 ......... :
N
18.2
Non-intrinsically protected tubes tested to 18.2
N
19
Stability and mechanical hazards
P
Mass of the equipment exceeding 7 kg ............. :
N
Apparatus intended to be fastened in place – suitable
instructions ......................................................... :
N
19.1
Test on a plane, inclined at 10o to the horizontal
P
19.2
100 N force applied vertically downwards
N
19.3
100 N force, or 13% of weight, applied horizontally to
point of least stability
P
19.4
Edges or corners not hazardous
P
19.5
Glass surfaces (exc.laminated) with an area
exceeding 0,1 m² or maximum dimension > 450 mm,
pass the test of 19.5.1
N
19.6
Wall or ceiling mountings adequate
N
20
Resistance to fire
P
20.1
Electrical components and mechanical parts
P
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
Result--Remark
Verdict
Metal enclosure provided
N
P
b) Exemption for small components as defined in
20.1
20.1.1
Electrical components meet the requirements of
Clause 14 or 20.1.4
Approval AC adapter used
20.1.2
Insulation of internal wiring working at voltages > 4 kV
or leaving an internal fire enclosure, or located within
the areas mentioned in Table 21, not contributing to
the spread of fire
N
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or better
to IEC 60707, unless used in a fire enclosure
N
TB-RF-076-3.0
P
Report No.: TB-LVD146103
Page:
21 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
Result--Remark
Verdict
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
N
Components and parts not covered by 20.1.1, 20.1.2
and 20.1.3 (other than fire enclosures) mounted
nearer to a potential ignition source than the
distances in Table 21 comply with the relevant
flammability category in Table 21
N
Components and parts as above but shielded from a
potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
N
Apparatus with voltages >4kV under normal
operating conditions and distances to the enclosure
exceed those specified Table 21, flammability
classification HB40 or better is required for the
enclosure
N
20.2
Fire enclosure
N
20.2.1
Potential ignition sources with open circuit
voltage > 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
N
20.2.2
Internal fire enclosures with openings not exceeding
1 mm in width and with openings for wires completely
filled
N
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an internal
fire enclosure
N
A
Annex A, Additional requirements for apparatus with protection against
splashing water
N
A.5
Marking and instructions
N
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
N
A.10
Insulation requirements
N
A.10.2
Splash and humidity treatment
N
A.10.2.1
Enclosure provides protection against splashing
water
N
A.10.2.2
Humidity treatment carried out for 7 days
N
B
Annex B, Apparatus to be connected to the TELECOMMUNICATION
NETWORKS
N
Complies with IEC 62151 clause 1
N
20.1.4
IPX0
No TNV.
Complies with IEC 62151 clause 2
N
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
22 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
Result--Remark
Verdict
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
N
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
N
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
standard
N
Complies with IEC 62151 clause 6
N
Complies with IEC 62151 clause 7
N
Complies with IEC 62151 annex A, B and C
N
L
ANNEX L, Additional requirements for electronic flash apparatus for
photographic purposes
N
L. 5
Marking and instructions
N
L. 5.4
Instructions for battery chargers and Supply
apparatus indicating type or model number of flash
apparatus with which it is to be used
No such equipment.
N
Instructions for flash apparatus indicating type or
model number of battery chargers or Supply
apparatus with which it is to be used
N
L. 7
Heating under normal operating conditions
N
L7.1.5 &
Lithium batteries meet permissible temp rise in Table
3, unless comply with 6.2.2.1 or 6.2.2.2 of IEC 600864
N
L. 9
Electric shock hazard under normal operating
conditions
N
L. 9.1.1
Terminals to connection to synchroniser not
HAZARDOUS LIVE
N
L.10
Insulation requirements
N
L. 10.3.2
High frequency puls ignition
N
L. 12
Mechanical strength
N
L. 12.1.3
Windows for flash tubes are excluded from steel ball
impact test
N
L. 14
Components
N
L14.6.6
Mains switch characteristics appropriate to its
function under normal conditions
N
L. 20
Resistance to fire
N
L. 20.1 c)
Trigger coil for discharge purpose is not considered to
be a POTENTIAL IGNITION SOURCE
N
L11.2.7
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
23 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
7.1
Requirement of the test
Result--Remark
Verdict
TABLE: temperature rise measurements:
P
Power consumption in the OFF/Stand-by mode of -the functional switch (W) .................................... :
—
Cond.
Un (V)
Hz
In (A)
1
12
--
4
Pn (W) Uout (V)
48
--
Pout
(W)
48
Operating Condition / Status
Total loaded 4A Max. Load and audio
input
Loudspeaker impedance (Ω) ............................. :
--
—
Several loudspeaker systems ............................. :
--
—
Marking of loudspeaker terminals ....................... :
--
—
Temperature Rise dT of Part
dT (K)
Test Condition No.
Limit max dT (K)
Cond. 1
--
(DC12V)
DC connector
11.2
50
USB port
10.5
30
PCB near MIC2
21.6
130-35=95
PCB near JT3
38.9
130-35=95
PCB near U1
46.7
130-35=95
Heat sink
46.2
Ref
Enclosure (external rear)
13.8
50
Enclosure (external top)
11.5
50
Winding temperature rise measurements
Ambient temperature t1 (oC) ................... :
25.3
—
Ambient temperature t2 (oC) ................... :
25.6
—
Temperature rise dT of winding:
dT = (R2 – R1) x (234.5 + t1) – (t2 – t1)
R1
R1 (Ω)
R2 (Ω)
dT (K)
Limit max
(K)
Insulation class
--
--
--
--
--
--
--
--
--
--
--
--
Note:
According to the user manual, the appliance is intended to be used in moderate climate, so the basic
ambient temperature is 35C
7.2
TABLE: softening temperature of thermoplastics
Temperature T of part
--
N
T - normal conditions (oC)
T - fault conditions (oC)
Min T softening
--
--
--
(oC)
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
24 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
10.3
Result--Remark
Verdict
TABLE: insulation resistance measurements
Insulation resistance R between:
--10.3
N
R (MΩ)
Required R (MΩ)
---
---
TABLE: electric strength measurements
Test voltage applied between:
--11.2
P
Test voltage (V)
---
Breakdown
---
TABLE: summary of fault condition tests
Voltage (V) 0,9 or 1,1 times rated voltage :
Frequency (Hz) ……………………..:
Ambient temperature (°C)
:
P
12 Vdc (powered by external
AC adapter)
-25.3 - 25.5
—
—
—
No Componen Fault
t
dT (K) / Component
Other results (include description
and test duration)
1
PCB near U1 dt = 44.1 K
Output current loaded to 0.9A for
single USB port,
USB output o-l
terminal
Enclosure (external top) dt = 17.1 K
No hazard, until steady conditions
established.
Uo = 12V, Io=3.52A
Test time: 3 h 20 min
2
Openings
blocked
PCB near U1 dt = 43.2 K
Enclosure (external top) dt = 17.2 K
No hazard, until steady conditions
established.
Uo = 12V, Io=3.4A
Test time: 3 h 12 min
3
USB output s-c
terminal
Unit shut down immediately,
recoverable, no hazard. No higher
temperature rise occurred.
--
Uo = 12V, Io=0.08A
4
U1
s-c
PCB near U1 dt = 43.6 K
Enclosure (external top) dt = 13.4 K
No hazard, until steady conditions
established.
Uo = 12V, Io=3.43A
Test time: 3 h 05 min
Note: N/A
13
TABLES: clearances and creepage distances
Rated supply voltage:
--
2 N force on internal parts applied:
Pollution degree:
N
--
Material Group:
--
--
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
25 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
Result--Remark
30 N force on outside of conductive enclosure applied:
Location
--
Operating Voltage
V rms
Verdict
Clearance (mm)
V peak
Min
Actual
Creepage
(mm)
Min
Actual
-
-
Circuits conductively connected to the mains (use Tables 8, 9 and 11): see note below.
Across mains fuse link (F1) (B)
-
-
-
-
Notes:
"Min" = minimum required.
"Actual = Actual dimensions measured.
B = Basic insulation, S = Supplementary insulation, R = Reinforced insulation.
14
TABLE: list of critical components and materials
Component
Manufacturer/
trademark
AC Adapter
Dongguan Fujia
Appliance Co., Ltd.
Type/model
FJSW1204000
Value / rating
Input: 100-240
V~, 50/60 Hz,
P
Standard
Approval/
Reference **)
--
Tested in
Appliance
1.5A Max. ;
Output: 12V
4A
Battery
----
CR2032
DC 3V
--
UL
PCB
Various
Various
V-0, 130C min
--
UL
Note: N/A
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
26 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
Result--Remark
Verdict
ATTACHMENT TO TEST REPORT IEC 60065
EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES
Audio, video and similar electronic apparatus – Safety requirements
Differences according to ............ : EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
IEC 60065, GROUP DIFFERENCES (CENELEC common modifications (EN))
Clause
Requirement + Test
Contents
Add the following annexes:
Result - Remark
Verdict

Annex ZA (normative) Other international publications quoted in this standard with
the references of the relevant European publications (See the CB Bulletin)
Annex ZB (nominative) Special national conditions
Annex ZC (informative) A-deviations
Definition
Add after the definition 2.2.12 the following new definition:

2.2.Z1
PORTABLE SOUND SYSTEM
(A11:2008) small battery powered audio equipment:
 whose prime purpose is to listen to recorded or broadcasted
sound; and
 that uses headphones or earphones that can be worn in or on
or around the ears; and
 that allows the user to walk around
NOTE Examples are mini-disc or CD players, MP3 audio players
or similar equipment.
2.2
In EN 60065:2002/A11:2008

(A12:2011) Delete the definition 2.2.Z1
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
27 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
3.1
Add the following indent at the end of the list
-
Result--Remark
Verdict

Exposure to excessive sound pressures from headphones or
earphones
NOTE A new method of measurement is described in EN 503321, Sound system equipment: Headphones and earphones
associated with portable audio equipment
– Maximum sound pressure level measurement methodology and
limit considerations – Part 1: General method for ”one package
equipment”, and in EN 50332-2, Sound system equipment:
Headphones and earphones associated with portable audio
equipment – Maximum sound pressure level measurement
methodology and limit considerations – Part 2: Guidelines to
associate sets with headphones coming from different
manufacturers.

In EN 60065:2002
(A12:2011) Delete the addition of indent regarding sound pressure excessive
3.1
3.Z1
After 3.2 add a new clause 3.Z1:
(A2:2010)
To protect against excessive current, short-circuits and earth
faults in MAINS, protective devices shall be included either as
integral parts of the equipment or as parts of the building
installation, subject to the following, a), b) and c):
N
a) except as detailed in b) and c), protective devices necessary to
comply with the requirements of 11 shall be included as parts of
the equipment;
b) for components in series or parallel with the mains input to the
equipment such as the supply cord, appliance coupler, r.f.i. filter
and switch, short-circuit and earth fault protection may be
provided by protective devices in the building installation;
c) it is permitted for equipment supplied via an industrial mains
plug or for PERMANENTLY CONNECTED APPARATUS, to rely
on dedicated over current and short-circuit protection in the
building installation, provided that the means of protection, e.g.
fuses or circuit breakers, is fully specified in the installation
instructions.
If reliance is placed on protection in the building installation, the
installation instructions shall so state, except that for not via an
industrial mains plug or for PERMANENTLY CONNECTED
APPARATUS the building installation shall be regarded
4.1.1
Replace the text of the note by: NOTE For ROUTINE TEST
reference is made to EN 50514.
5.4.1
za)
Modify indent za) as follows:
za) For a PORTABLE SOUND SYSTEM, a warning that excessive
(A11:2008) sound pressure from earphones and headphones can cause
hearing loss.

Not such
equipment.
N
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
28 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
5.4.1
In EN 60065:2002/A1:2006 and EN 60065;2002/A11:2008
Result--Remark
(A12:2011) Delete the modification in indent za)
Not such
equipment.
Verdict
N
Add the following clause and annex to the excisting standard and
amendments
Zx Protection against excessive sound pressure from personal music players
N
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
29 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
Result--Remark
Zx.1 General
This sub-clause specifies requirements for protection against
excessive sound pressure from personal music players that
are closely coupled to the ear. It also specifies requirements
for earphones and headphones intended for use with
personal music players.
Verdict
N
A personal music player is a portable equipment for
personal use, that:
is designed to allow the user to listen to recorded or
broadcast sound or video; and
primarily uses headphones or earphones that can
be worn in or on or around the ears; and allows the user to
walk around while in use.
NOTE 1 Examples are hand-held or body-worn portable CD
players, MP3 audio players, mobile phones with MP3 type
features, PDA’s or similar equipment.
A personal music player and earphones or headphones
intended to be used with personal
music players shall comply with the requirements of this subclause.
The requirements in this sub-clause are valid for music or
video mode only.
The requirements do not apply:
while the personal music player is connected to an
external amplifier; or while the headphones or earphones are
not used.
NOTE 2 An external amplifier is an amplifier which is not part
of the personal music player or the listening device, but which
is intended to play the music as a standalone music player.
The requirements do not apply to:
hearing aid equipment and professional
equipment;
NOTE 3 Professional equipment is equipment sold through
special sales channels. All products sold through normal
electronics stores are considered not to be professional
equipment.analogue personal music players (personal music
players without any kind of digital processing of the sound
signal) that are brought to the market before the end of 2015.
NOTE 4 This exemption has been allowed because this
technology is falling out of use and it is expected that within a
few years it will no longer exist. This exemption will not be
extended to other technologies.
For equipment which is clearly designed or intended for use
by young children, the limits of
EN 71-1 apply.
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
30 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Cont.
Requirement of the test
Zx.2 Equipment requirements
No safety provision is required for equipment that complies
with the following:
equipment provided as a package (personal music
player with its listening device), where
the acoustic output LAeq,T is ≤ 85 dBA measured while
playing the fixed “programme
simulation noise” as described in EN 50332-1; and
a personal music player provided with an analogue
electrical output socket for a listening
device, where the electrical output is ≤ 27 mV
measured as described in EN 50332-2, while playing the
fixed “programme simulation noise” as described in EN
50332-1.
NOTE 1 Wherever the term acoustic output is used in this
clause, the 30 s A-weighted equivalent sound pressure level
LAeq,T is meant. See also Zx.5 and Annex Zx.
All other equipment shall:
a) protect the user from unintentional acoustic
outputs
exceeding those mentioned above; and
b) have a standard acoustic output level not exceeding
those mentioned above, and
automatically return to an output level not exceeding
those mentioned above when the
power is switched off; and
c) provide a means to actively inform the user of the
ncreased sound pressure when the equipment is
operated with an acoustic output exceeding those
mentioned above. Any means used shall
be
acknowledged by the user before activating a mode of
operation which allows for an acoustic output exceeding
those mentioned above. The acknowledgement does not
need to be repeated
more than once every 20 h of
cumulative listening time; and
NOTE 2 Examples of means include visual or audible signals.
Action from the user is always required.
NOTE 3 The 20 h listening time is the accumulative listening
time, independent how often and how long the personal
music player has been switched off.
d) have a warning as specified in Zx.3; and
e) not exceed the following:
1) equipment provided as a package (player with Its
listening device), the acoustic output shall be ≤ 100 dBA
measured while playing the fixed
“programme
simulation noise” described in EN
50332-1; and
2) a personal music player provided with an
analogue electrical output socket for a listening
device,
the electrical output shall be ≤ 150 mV
measured as
described in EN 50332-2, while
playing the fixed
“programme simulation noise” described in EN 50332-1.
Result--Remark
Verdict
N
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
31 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
For music where the average sound pressure (long term
LAeq,T) measured over the duration of the song is lower
than the average produced by the programme simulation
noise, the warning does not need to be given as long as the
average sound pressure of the song is below the basic limit
of 85 dBA. In this case T becomes the duration of the song.
Result--Remark
Verdict
N
NOTE 4 Classical music typically has an average sound
pressure (long term LAeq,T) which is much lower than the
average programme simulation noise. Therefore, if the player
is capable to analyse the song and compare it with the
programme simulation noise, the warning does not need to
be given as long as the average sound pressure of the song
is below the basic limit of 85 dBA.
For example, if the player is set with the programme
simulation noise to 85 dBA, but the average music level of
the song is only 65 dBA, there is no need to give a warning or
ask an acknowledgement as long as the average sound level
of the song is not above the basic limit of 85 dBA.
Zx.3 Warning
The warning shall be placed on the equipment, or on the
packaging, or in the instruction manual and shall consist of
the following:
the symbol of Figure 1 with a minimum height of
5 mm; and the following wording, or similar:
N
“To prevent possible hearing damage, do not listen at high
volume levels for long periods.”
Figure 1 – Warning label (IEC 60417-6044)
Alternatively, the entire warning may be given through the
equipment display during use,
when the user is asked to acknowledge activation of the
higher level.
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
32 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
Cont.
Zx.4 Requirements for listening devices (headphones and earphones)
N
Zx.4.1 Wired listening devices with analogue input
Not such equipment.
With 94 dBA sound pressure output LAeq,T, the input voltage
of the fixed “programme simulation noise” described in EN
50332-2 shall be ≥ 75 mV.
N
Result--Remark
Verdict
This requirement is applicable in any mode where the
headphones can operate (active or
passive), including any available setting (for example built-in
volume level control).
NOTE The values of 94 dBA – 75 mV correspond with 85dBA
– 27 mV and 100 dBA – 150 mV.
Not such equipment.
N
Zx.4.3 Wireless listening devices
Not such equipment.
In wireless mode:
with any playing and transmitting device playing the
fixed programme simulation noise described in EN 50332-1;
and respecting the wireless transmission standards, where
an air interface standard exists that specifies the equivalent
acoustic level; and with volume and sound settings in the
listening device (for example built-in volume level control,
additional sound feature like equalization, etc.) set to the
combination of positions that maximize the measured
acoustic output for the above- mentioned programme
simulation noise, the acoustic output LAeq,T of the listening
device shall be ≤ 100 dBA.
N
Zx.4.2 Wired listening devices with digital input
With any playing device playing the fixed “programme
simulation noise” described in
EN 50332-1 (and respecting the digital interface standards,
where a digital interface standard
exists that specifies the equivalent acoustic level), the
acoustic output LAeq,T of the listening device shall be ≤ 100
dBA.
This requirement is applicable in any mode where the
headphones can operate, including any available setting (for
example built-in volume level control, additional sound
feature like
equalization, etc.).
NOTE An example of a wired listening device with digital
input is a USB headphone.
NOTE An example of a wireless listening device is a
Bluetooth headphone.
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
33 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
Zx.5 Measurement methods
Measurements shall be made in accordance with EN 50332-1
or EN 50332-2 as applicable.
Unless stated otherwise, the time interval T shall be 30 s.
Result--Remark
Verdict
N
NOTE Test method for wireless equipment provided without
listening device should be defined.
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
34 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
Result--Remark
6.1
Replace the entire subclause in EN 60065:2002 and EN
60065:2002/A1:2006 by:
No ionizing radiation.
Verdict
N
(A11:2008) Ionizing radiation
Apparatus including a potential source of ionizing radiation
shall be so constructed that personal
protection against ionizing radiation is provided under normal
operating conditions and under fault
conditions.
Compliance is checked by measurement under the following
conditions:
In addition to the normal operating conditions, all controls
adjustable from the outside BY HAND, by any object such as
a tool or a coin, and those internal adjustments or pre-sets
which are not locked in a reliable manner, are adjusted so as
to give maximum radiation whilst maintaining an intelligible
picture for 1 h, at the end of which the measurement is made.
NOTE 1 Soldered joints and paint lockings are examples of
adequate locking.
The dose-rate is determined by means of a radiation monitor
with an effective area of 10 cm², at any point 10 cm from the
outer surface of the apparatus.
Moreover, the measurement shall be made under fault
conditions causing an increase of the high-voltage, provided
an intelligible picture is maintained for 1 h, at the end of which
the measurement is made.
The dose-rate shall not exceed 1μSv/h (0,1 mR/h) taking
account of the background level.
NOTE 2 These values appear in Directive 96/29/Euratom of
13th May 1996.
A picture is considered to be intelligible if the following
conditions are met:
- a scanning amplitude of at least 70 % of the usable screen
width;
- a minimum luminance of 50 cd/m² with locked blank raster
provided by a test generator;
- a horizontal resolution corresponding to at least 1,5 MHz in
the centre, with a similar vertical degradation;
- not more than one flashover per 5 min.
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
35 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
Z1
Add the following new clause after Clause 20:
Result--Remark
Verdict
N
(A11:2008) Z1 Resistance to candle flame ignition
A television set shall be so designed that the likelihood of
ignition and the spread of fire caused by a candle flame is
reduced.
NOTE 1 An apparatus with a viewing screen is not regarded
to be a television set if it is declared not to be so by the
manufacturer.
This requirement does not apply to the display screen of rear
projection TV’s.
NOTE 2 This exemption has been allowed because this
technology is falling out of use and it is expected that within a
few years it will no longer exist. This exemption will not be
extended to other technologies.
NOTE 3 The frame around the screen is not exempted from
the requirements.
Wood and WOOD-BASED MATERIAL with a thickness of at
least 6 mm is considered to fulfil the V-1 requirement when
applying CLC/TS 62441.
Compliance is checked according to CLC/TS 62441.
NOTE 4 The term vertical, as used in the first dash of clause
5.2 of CLC/TS 62441, does not mean a perfectly vertical
position. It should be interpreted as any surface that can be
touched by the flame of a candle of 150 mm height and
20mm diameter while the candle is still touching the
supporting surface. A typical candle used in the home is
assumed to be 20 mm diameter.
NOTE 5 It is expected that CLC/TS 62441 will in the future be
replaced by a standard, at which time that standard will
become applicable, subject to a vote by National Committees
at the time.
General
13.3.1
14
15.1.1
15.2
16.1
16.2
20
Annex B
Annex G
Annex J.2
Annex N
Delete note 4.
Delete note 4 and note 5.
Delete notes 1 and 2.
Delete note 2.
Delete note 1.
Delete the note.
Delete note 2.
Replace note 1 by: In the CENELEC countries listed in IEC 62151,
special national conditions apply.
Delete the note.
Delete the notes of Table J.1.
Add after the introduction: For ROUTINE TEST reference is made to
EN 50333. (Replaced by EN 50514)

TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
36 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
General
In IEC 60065:2001/A2
(A2:2010)
Delete all the “country” notes according to the following list:
5.3
Note
5.4.1 Note
20
Note
Result--Remark
Verdict

For special national conditions, see Annex ZB.
Bibliography Additional EN standards.

ZA
Normative references to international publications
with their corresponding European publications
P
ZB
ANNEX ZB TO EN 60065, SPECIAL NATIONAL CONDITIONS (EN)
P
2.6.1
DK: The following is added:
N
Certain types of CLASS I apparatus, see 15.1.1, may be
provided with a plug not establishing earthing continuity when
inserted in Danish socket-outlets
Justification: Heavy Current Regulations, Section 107.
3.Z1
Denmark
(A2:2010)
Add to the end of the subclause
Non-class I
apparatus
N
Due to many existing installations where the socket-outlets
can be protected with
fuses with higher rating than the rating of the socket-outlets
the protection for
pluggable equipment type A shall be an integral part of the
equipment.
Justification:
In Denmark an existing 13 A socket outlet can be protected
by a 20 A fuse.
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
37 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
Result--Remark
5.3
Finland, Norway and Sweden
N
(A2:2010)
To the end of the subclause the following is added:
Non-class I
apparatus
Non-class I
apparatus
N
Verdict
CLASS I apparatus which is intended for connection to the
building installation wiring
via a plug or an appliance coupler, or both and in addition is
intended for connection
to other apparatus or a network shall, if safety relies on
connection to protective earth
or if surge suppressors are connected between the network
TERMINALS and
ACCESSIBLE parts, have a marking stating that the
apparatus must be connected to an
earthed MAINS socket-outlet.
The marking text in the applicable countries shall be as
follows:
In Finland: "Laite on liitettävä suojakoskettimilla varustettuun
pistorasiaan"
In Norway: “Apparatet må tilkoples jordet stikkontakt”
In Sweden: “Apparaten skall anslutas till jordat uttag”
5.4
Finland, Norway and Sweden
(A11:2008) To the end of 5.4 the following is added:
CLASS I apparatus which is intended for connection to the
building installation wiring via a plug or an appliance coupler,
or both and in addition is intended for connection to other
apparatus or a network shall, if safety relies on connection to
protective earth or if surge suppressors are connected
between the network TERMINALS and ACCESSIBLE parts,
have a marking stating that the apparatus must be connected
to an MAINS socket-outlet with protective earth.
The marking text in the applicable countries shall be as
follows:
In Finland: “Laite on liitettävä suojamaadoituskoskettimilla
varustettuun pistorasiaan”
In Norway: “Apparatet må tilkoples jordet stikkontakt”
In Sweden: "Apparaten skall anslutas till jordat uttag"
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
38 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
Result--Remark
5.4.1
Norway and Sweden
No cable distribution
system
(A11:2008) To the end of 5.4.1 (after the compliance statement) the
following is added:
Verdict
N
The screen of the cable distribution system is normally not
earthed at the entrance of the building and there is normally
no equipotential bonding system within the building.
Therefore the protective earthing of the building installation
need to be isolated from the screen of a cable distribution
system.
It is however accepted to provide the insulation external to
the equipment by an adapter or an interconnection cable with
galvanic isolator, which may be provided by e.g. a retailer.
The user manual shall then have the following or similar
information in Norwegian and Swedish language respectively,
depending on in what country the equipment is intended to be
used in:
“Equipment connected to the protective earthing of the
building installation through the mains connection or through
other equipment with a connection to protective earthing –
and to a cable distribution system using coaxial cable, may in
some circumstances create a fire hazard. Connection to a
cable distribution system has therefore to be provided
through a device providing electrical isolation below a certain
frequency range (galvanic isolator, see EN 60728-11)”
NOTE In Norway, due to regulation for installations of cable
distribution systems, and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The insulation shall
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60
Hz, for 1 min.
Translation to Norwegian (the Swedish text will also be
accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via nettplugg og/eller
via annet jordtilkoplet utstyr – og er tilkoplet et kabel-TV nett,
kan forårsake brannfare. For å unngå dette skal det ved
tilkopling av utstyret til kabel-TV nettet installeres en
galvanisk isolator mellom utstyret og kabel-TV nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via jordat vägguttag
och/eller via annan utrustning och samtidigt är kopplad till
kabel-TV nät kan i vissa fall medföra risk för brand.
Főr att undvika detta skall vid anslutning av utrustningen till
kabel-TV nät galvanisk isolator finnas mellan utrustningen
och kabel-TV nätet.”
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
39 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
Result--Remark
13.3.1
NO: To the second paragraph the following is added:
Supplied by SELV
N
No socket outlet.
N
Verdict
In Norway, due to the IT power distribution system used, the
a.c. MAINS supply voltage is considered to be equal to the
line-to-line voltage, and will remain 230 V in case of a single
earth fault.
Justification: Based on a use in Norway of an IT power
distribution system where the neutral is not provided.
15.1.1
Denmark
(A11:2008) The text of the Danish SNC in EN 60065:2002 has been
modified as follows:
To the first paragraph the following is added:
In Denmark, supply cords of single-phase appliances having
a rated current not exceeding 13 A shall be provided with a
plug according to the Heavy Current Regulations Section
107-2-D1.
Appliances of CLASS I provided with socket-outlets with earth
contact or which are intended to be used in locations where
protection against indirect contact is required according to the
wiring rules shall be provided with a plug in accordance with
the Heavy Current Regulations, Section 107-2-D1 standard
sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for providing power to CLASS II
apparatus with a rated current of 2,5 A shall be in accordance
with the Heavy Current Regulation, Section 107-2-D1
standard sheet DKA 1-4a.
Other current ratings socket outlets shall be in compliance
with the Heavy Current Regulation, Section 107-2-D1
standard sheet DKA 1-3a or DKA 1-3b.
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall be in
compliance with the Heavy Current Regulation, Section 1072-D1 standard sheet DK 1-3a, DK 1-5a or DK 1-7a.
Justification: Heavy Current Regulations, Section 107-2-D1
15.1.1
IE: Apparatus which is fitted with a flexible cable or cord shall Supplied by SELV
be provided with a 13 A plug in accordance with Statutory
Instrument 525:97, “13 A Plugs and Conversion Adapters for
Domestic Use Regulations:1997.
N
Justification: SI 525: 1997
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
40 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
15.1.1
NO: Mains socket-outlets mounted on CLASS II apparatus
shall comply with the specifications given in CEE Publ. 7 as
far as a applicable, with the following amendments:
Result--Remark
Verdict
P
§ 8 Dimensions
a 2.5 A 250 V two-pole socket-outlets for electronic apparatus
shall comply with the enclosed Standard Sheet I.
§ 24 Mechanical strength
A 2,5 A 250 V socket-outlets for CLASS II electronic
apparatus are tested as specified in 12.1.3 of EN 60065. Also
the protecting rim shall be tested
Justification: Act of 24 May 1929 relating to supervision of
electrical installation (TEA 1929/FEL 1998).
15.1.1
UK: Apparatus which is fitted with a flexible cable or cord and Supplied by SELV
is designed to be connected to a mains socket conforming to
BS 1363 by means of that flexible cable or cord and plug
shall be fitted with a ”standard plug” in accordance with
Statutory Instrument 1768: 1994: The Plugs and Sockets etc.
(Safety) Regulations 1994, unless exempted by those
Regulations.
N
NOTE ”Standard plug” is defined in SI 1768:1994 and
essentially means an approved plug conforming to BS 1363
or an approved conversion plug.
Justification: SI 1768: 1994
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
41 of 44
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
CL.
Requirement of the test
Result--Remark
J.2
NO: After Table J.1 the following is added:
Supplied by SELV
Verdict
P
In Norway, due to the IT power distribution system used, the
a.c. MAINS supply voltage is considered to be equal to the
line-to-line voltage, and will remain 230 V in case of a single
earth fault.
Justification: Based on a use in Norway of an IT power
distribution system where the neutral is not provided.
ZC
ANNEX ZC TO EN 60065, A-DEVIATIONS (EN)
P
5.1
IT: Additional markings on the outside of the TV receiver in
Italian language
N
IT:User instructions in Italian language including a conformity
declaration
N
IT: Certification number on the back cover
N
6.1
DE: The following requirement applies:
For the operation of any cathode ray tube intended for the
display of visual images operating at an acceleration voltage
exceeding 40 kV, authorization is required, or application of
type approval (Bauartzulassung) and marking.
No cathode ray tube
used.
N
Justification: German ministerial decree against ionizing
radiation (Röntgenverordnung), in force since 2002-07-01,
implementing the European Directive 96/29/EURATOM.
NOTE Contact address:
Physikalisch-Technische Bundesanstalt, Bundesallee 100, D38116 Braunschweig, Tel.: Int+49-531-592-6320, Internet:
http://www.ptb.de
14
SE: Switches containing mercury such as thermostats, relays No such switch
and level controllers are not allowed.
used.
N
Justification: Ordinance (1990:944) on Prohibition in
Connection with handling. Importation and exportation of
Chemical Products (Certain Cases)
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
42 of 44
EUT Photos
Photo 1 Overview of EUT
Photo 2 Overview of EUT
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
43 of 44
Photo 3 Interior of EUT
Photo 4 Appearance of PCB
TB-RF-076-3.0
Report No.: TB-LVD146103
Page:
44 of 44
Photo 5 Appearance of PCB
END OF REPORT