Bticino 344612 is a technologically advanced video internal unit for 2-wire digital systems with a 7" touch screen display. It enables users to manage video door entry calls, communicate with other internal units, activate actuators, and utilize various functions through its intuitive interface. With its modern design and compact size, it seamlessly integrates into any home or office environment.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Manual
Bticino 344612 manual | Manualzz

www.bticino.com

Classe 300

Installation Manual

Classe 300

Installation Manual

Contents

Classe 300

Installation Manual

General information

Warnings and recommendations

Front view

Rear view

Dimensional data and installation heights

Wall-mounted installation

Installation on the table-top base

Physical configuration

9

10

Configurators 11

7

8

4

6

4

4

Functions of the M units configurator (Favorites key)

Functions of the M tenths configurator (Quick actions)

First switching on

Settings

General settings

Ringtones

Display

Answering machine (only for item 344622)

Quick actions

Configuration 29

Advanced Configuration 31

First switching on 31

Configuration 34

General settings 35

12

13

17

19

19

22

23

25

27

Intercom

Camera

Activation

Change password

Quick actions

Factory configuration

41

42

44

35

37

39

3

Classe 300

Installation Manual

16

15

14

General information

Warnings and recommendations

It is important to read this manual carefully before proceeding with the installation.

The guarantee automatically expires for negligence, misuse, tampering by unauthorized personnel.

The Classe 300 Video internal unit must only be installed indoors; it must not be exposed to water drops or splashes; it must be used only on BTicino 2 wire digital systems.

Front view

1 2 3 4 5 6 7

10:36

Tuesday, 22 April

17

Answering machine Cameras Memo

Intercom Activations Settings

Quick Actions

Private camera

External intercom

Pager

Lock

8

9 13 12 11 10

The image shows the device with all its functions enabled.

Check on the installer manual how to enable the functions.

1. 7” touch screen display (16 : 9)

2. Screen OFF key

3. Time and date

4. Ringtone exclusion

5. Professional Studio (Office) activation

6. Microphone

7. Answering machine activation (only models 344622)

8. Quick actions

9. Tactile guides

10. Connection key:

The green LED flashes to indicate an incoming call

The green LED comes on steady to indicate that there is an active call

11. Auto-switching on/Scrolling: the red LED turns on when the key is pressed

9

4

Classe 300

Installation Manual

12. Favorites key: the red LED turns on when the key is pressed

(Basic configuration = STAIRCASE LIGHT. For a different configuration refer to the physical configuration

table

)

13. Door lock release key: the red LED turns on when the key is pressed

14. Answering machine Status (only models 344622):

Red LED steady = answering machine active

Red LED flashing = new recording/s

15. Message status:

Red LED flashing = new unread note/s

16. Bell exclusion Status:

Red LED on = Call ringtone disabled

17. Functions (only the icons for the configured functions are displayed)

5

Classe 300

Installation Manual

Rear view

1 2 3

6

10 9 8 7

1. Configurator socket

2. Configurator J1: remove for additional power supply

3. J2 configurator: Master/Slave, remove for Slave

4. Line termination ON/OFF micro-switch

5. Mini USB socket for device Firmware update using the MyHomeSuite software

Note: the device must be powered (1-2 or BUS)

6. Loudspeaker

7. Additional power supply clamps (1 - 2)

8. 2 WIRE SCS/BUS connection clamps

9. Clamps ( ) for the connection of an external call to the floor pushbutton

10. Additional ringtone connection clamps (1 - 5M)

Point-to-Point connections are required on the clamps of the additional ringtones

6

4

5

6

Dimensional data and installation heights

194 mm

10:36

Tuesday, 22 April

Answering machine Cameras Memo

Intercom Activations Settings

Quick Actions

Private camera

External intercom

Pager

Lock

Classe 300

Installation Manual

25 mm

Height recommended, unless otherwise required by the law

7

Classe 300

Installation Manual

Wall-mounted installation

1

3

8

4

2

Installation on the table-top base

Classe 300

Installation Manual

Warning: position the microswitch on ON to terminate the line.

10:

Tue sda

36 y, 2

2 A pril

An sweri ng m ach ine

Cam era s

Act ivat ions

Mem o s

Qu ick

Ac tion

Priv ate

cam era

Exte rna l inte rco m

Pag er

Lock

Set ting s

Inte rco m

8-way socket:

336982/83/84 Livinglight

349414/15/18 Axolute

5 6

7

8

5 6

7

8

1-2

1-2

3

4

1

2

7

8

5

6 3

4

1

2

7

8

5

6

BUS

BUS

9

Classe 300

Installation Manual

Physical configuration

The device must be configured both physically or in

advanced mode , the main differences are

shown in the following table:

Warning: the connection of the configurators to the N - P - M sockets precludes the possibility of using the advanced configuration.

The configuration must be performed with the device disconnected from the power supply.

Before using it, wait for the LEDs to stop flashing.

Available Functions

FAVORITES KEY

QUICK ACTIONS

Private camera

External intercom

Physical Configuration

Possibility of assigning various functions

See “Functions of the M units configurator (Favorites key)”

Preset:

See “Functions of the M tenths configurator (Quick actions)”

The user can rename, delete and add back, only the preset functions

Advanced Configuration

Staircase Light function

Creating quick actions of all functions

The user can decide the quick actions to display in the home page

Pager

Lock

FUNCTIONS The use of the functions is only available through quick actions in the home page

See “Functions of the M tenths configurator (Quick actions)”

Dedicated icons in the home page and customisable, configurable functions

See “Configuration”

Cameras

Intercom

Activations

10

Classe 300

Installation Manual

Configurators

1 2 3

J1 J2 N

4

P

5

M

Configurator functions

1. J1 = Remove if the additional power supply is present (clamp 1 – 2)

2. J2 = Master/Slave (remove for slave)

3. NN = Device address

4. PP = Address of the EP of which you can open the Door Lock with IU idle, and to which you can send the auto-on command

5. MM = Mode of operation according to the tables on the following pages

M units = Configuration of the FAVORITES capacitive key

M tenths = Configuration of the QUICK ACTIONS in the Home page

If the device is configured physically, the configuration MUST NOT BE MODIFIED using the menu.

11

Classe 300

Installation Manual

Functions of the M units configurator (Favorites key)

J1 J2 N

MM = 0

MM = 1

MM = 2

MM = 3

P M

Staircase Light Control

Direct control of P+1 Door lock

Direct control of P+2 Door lock

Direct control of P+3 Door lock

MM = 4

MM = 5

MM = 6

MM = 7

P+1 direct auto-switching on

P+2 direct auto-switching on

P+3 direct auto-switching on

General Intercom

MM = 8 Internal intercom

MM = 9

Enabling/disabling Professional Studio (Office) function

12

P

P

P+1

P+1

MOD=9

P +2

P+2

P+2

MOD=9

P +3

P+3

P+3

MOD=9

P+1

346210

346210

346210

P+1 P+1

P+1 P+1

MOD=5

P+2

346210

346210

346210

P+2 P+2

P+2 P+2

MOD=5

P+3

346210

346210

346210

P+3 P+3

P+3 P+3

MOD=5

P

P

346210

P

P +1

P

+1

P+1

MOD=9

P+1

MOD=9

P +1

P +2

P +2

MOD=9

P+2

MOD=9

P+2

346210 MOD=9

P +2

P +3

P +3

P +3

MOD=9

P+3

MOD=9

P+3

MOD=9

P+3

MOD=9

Classe 300

Installation Manual

Functions of the M tenths configurator (Quick actions)

The MM - (tenths) physical configurator decides which are the 4 QUICK ACTIONS icons that appear

on the HOME PAGE, and can be activated by touching the display.

J1 J2

P

P

P

P

N

–+ 23

P M

P

P

P

P

+1

+1

+1

+1

–+ 23 P+1

–+ 23 MOD=9

–+ MOD=9 23 P+1

P+1

MOD=9

–+ 23

The possible configurations are shown in the following table

P

P

P +2

–+

–+

23 MOD=9

23 MOD=9

P+2

MOD=9

P

P

P

+3

+3

+3

346210

–+ 23

–+ 23 P+3

MOD=9

MOD=9

P+3

MOD=9

Activation of the EP (configured with P+1) directly without call or activation of the actuator item 346200/346210 (configured with P+1 and

MOD=9).

–+ 23

P +2

346210

346210

P+1

P+1

P+1

P+1

23

346210

EP door lock release (configured with P+1), directly without call, or activation of the actuator item 346200/346210 (configured with P+1 and

MOD=5), or activation of door lock actuators item 346230 (configured with P+1)

P 346210 +3

MOD=5

MOD=5

346210

P+2

P+2

P+2

P+1

346210

P+2

P+2 P+2

MOD=5

MOD=5

P+2 P+2

MOD=5

P+3

P+3

346210

346210

P+3

346210 MOD=5

346210

P+3 P+3

MOD=5

MOD=5

346210

P+4

P+4

P+3

346210

P+4

P+4

P+4 P+4

MOD=5

P+4 P+4

MOD=5

MOD=5

EP door lock release (configured with P+2), directly without call, or activation of the actuator item 346200/346210 (configured with P+2 and

MOD=5), or activation of door lock actuators item 346230 (configured with P+2)

EP door lock release (configured with P+3), directly without call, or activation of the actuator item 346200/346210 (configured with P+3 and

MOD=5), or activation of door lock actuators item 346230 (configured with P+3)

EP door lock release (configured with P+4), directly without call, or activation of the actuator item 346200/346210 (configured with P+4 and

MOD=5), or activation of door lock actuators item 346230 (configured with P+4)

P+4

346210

P+4 P+4

MOD=5

Intercom among apartments in systems with apartment interface item

346850.

Intercom inside the apartment, in systems with apartment interface item

346850, or intercom among apartments in systems without apartment interface.

Internal intercom. It sends the call to all the handsets with the same address.

General intercom. It sends the call to all the handsets of the system.

13

Classe 300

Installation Manual

P

0 1

M

Myself

Poste externe 1

Lock 1

Lock 2

Pager

Camera 1

Lock 1

Lock 2

P

0 2

M P

0 3

M

Myself

Intercom 1

Camera 1

Lock 1

346210

P +1 P+1

MOD=9

P+1

346210

P+1 P+1

MOD=5

P+2

346210

P+2 P+2

MOD=5

346210

P +1 P+1

MOD=9

P+1

346210

P+1 P+1

MOD=5

P+2

346210

P+2 P+2

MOD=5

N=1 N=2

N=2 N=1

346210

P +1 P+1

MOD=9

P+1

346210

P+1 P+1

MOD=5

14

P+1

346210

P+1 P+1

MOD=5

P+2

346210

P+2 P+2

MOD=5

P

0 4

M

Intercom 2

Intercom 3

Lock 1

Lock 2

N=1 N=3

N=2

N=2 N=3

N=1

N=3 N=2

N=1

P+1

346210

P+1 P+1

MOD=5

P+2

346210

P+2 P+2

MOD=5

P

0 5

M

Intercom 2

Intercom 3

Lock 1

Lock 2

N=1

N=2

N=3

N=2

N=1

N=3

N=3

N=1

N=2

N=2 N=1 N=4

N=3 N=5

N=3 N=1 N=4

N=2 N=5

N=4 N=1 N=3

N=2 N=5

N=5 N=1 N=3

N=2 N=4

Classe 300

Installation Manual

P

0 6

M

Intercom 2

Intercom 3

Intercom 4

Intercom 5

N=1 N=2 N=3

N=4 N=5

15

Classe 300

Installation Manual

N=2 N=1 N=4

N=3 N=5

N=3 N=1 N=4

N=2 N=5

N=4 N=1 N=3

N=2 N=5

P

0 7

M

Intercom 2

Intercom 3

Intercom 4

Intercom 5

N=1 N=2 N=3

N=4 N=5

P

0 8

M

Camera 1

Intercom 1

Lock 1

Lock 2

346210

P +1 P+1

MOD=9

N=1 N=2

N=2 N=1

P+1

346210

P+1 P+1

MOD=5

P+2

346210

P+2 P+2

MOD=5

P+3

346210

P+3 P+3

MOD=5

P+4

346210

P+4 P+4

MOD=5

Lock 1

Lock 2

Lock 3

Lock 4

P

0 9

M

P+1

346210

P+1 P+1

MOD=5

P+2

346210

P+2 P+2

MOD=5

16

Classe 300

Installation Manual

First switching on

After the device has been configured physically and connected, it is mandatory to perform the customisations using the menu.

Wait for the LEDS to stop flashing and then touch the display to switch it on.

Languages Next

1

English

Français

Italiano

Español

Deutsch

Néerlandais

Português

2

1. Touch the icon for the desired language.

2. Touch to continue.

Back Time and date Next

4

11 d

11 42 m

10 m

2013 y

3

5

3. Touch the icon for the parameter to set (date or time); the icons to increase or decrease the value appear.

4. Touch to set it.

5. Touch to continue.

17

Classe 300

Installation Manual

Now it is possible to display information concerning the configuration of the device

Back

6

Info

N

00

P

00

Master/Slave

Power supply

Firmware ver.

Professional studio

Answering machine

Master

Disabled

1.0.12

Enabled

Enabled

M

20

Display:

A. The configuration parameters.

B. If the device has been set as apartment master or slave.

C. If an additional power sully is present.

D. The firmware version of the device.

E. If the Professional Studio (Office)

function is active.

F. If the Answering machine

function is active (only for item 344622).

6. Touch to end the procedure.

End

10:36

Tuesday, 22 April 7

Quick Actions

Pager

Camera 1

Answering machine Memo Settings Lock 1

Lock 2

7. Touch to proceed with the device customisation in the Settings

section.

A

B

C

D

E

F

18

Classe 300

Installation Manual

Settings

Generals

Ringtones

Display

Answering machine

Quick Actions

Configuration

Time and date/Language/Information/Key tone

Volume/Intercom ringtone/Entrance Panel Ringtone/Other ringtones...

Clean monitor/Background/Calibration

Recording Mode/Welcome Message/Record Message...

Add quick action

Activation of Answering machine/ Professional Studio (Office)

General settings

This section contains the general settings and device information.

Back Settings

Generals

Ringtones

Display

Answering machine

Quick Actions

Configuration

Time and date

Language

Info

Tone buttons A

A. Enable/disable the sound when a key is pressed.

19

Classe 300

Installation Manual

Time and date

Set the current time and date.

Back Time and date

2

11 d

11 42 m

10 m

2013 y

1

1. Touch the icon for the parameter to set; the icons to increase or decrease the value appear.

2. Touch to set it.

Language

Set the device language.

Back Languages

English

Français

Italiano

Español

Deutsch

Néerlandais

Português

1

1. Touch the icon for the desired language.

20

Classe 300

Installation Manual

Information

It displays information concerning the configuration of the device.

Back Info

N

00

P

00

Master/Slave

Power supply

Firmware ver.

Professional studio

Answering machine

Master

Disabled

1.0.12

Enabled

Enabled

M

00

1

End

Display:

A. The configuration parameters.

B. If the device has been set as apartment master or slave.

C. If an additional power sully is present.

D. The firmware version of the device.

E. If the Professional Studio (Office)

function is active.

F. If the Segreteria

function is active (only for item 344622).

1. Touch to go back and save the settings.

A

B

C

D

E

F

21

Classe 300

Installation Manual

Ringtones

This section can be used to associate specific ringtones to certain events, and to adjust their volume.

Back Settings

A

Volume

Generals

Ringtones

Answering machine

Quick Actions

Configuration

Main entrance panel

16

Internal intercom

1

1

More ringtones...

2

A. Adjust the ringtone volume.

1. Touch the event box to which to associate a specific ringtone; the selection arrows appear.

2. Scroll through the available ringtones (16); they will be played back as you scroll through them.

3. Touch to go back and save the settings.

Events to which it is possible to associate ringtones:

Main Entrance Panel: call from the main entrance panel (S0)

Internal intercom: call from an intercom in your apartment.

Other ringtones...

S1, 2, 3 Entrance Panel: call from the SECONDARY Entrance Panel (S1; S2; S3)

External intercom: call from an intercom of another apartment.

Call to the floor: call from the pushbutton outside your entrance door.

Notifications: memo from the switchboard.

22

Classe 300

Installation Manual

Display

This section is used to calibrate, clean the monitor, and to change the background image.

Back Settings

Generals

Ringtones

Display

Answering machine

Quick Actions

Configuration

Clean monitor

Background

Calibration

Clean monitor

It’s used to disable the display and the keys for cleaning purposes, without the risk of sending unwanted commands.

A

10

1

A. After touching the corresponding icon, the display remains in stand-by for 10 seconds.

1. during this period, it is possible to clean the monitor and the keys.

Caution: do not clean with solvents, thinners etc. or abrasive products. Only use a soft cloth.

23

Classe 300

Installation Manual

Background

It gives the possibility to change the background image of the device.

Back

Background

2 home

1. Scroll through the available images to get a background preview.

2. Touch to go back and save the settings.

Calibration

It can be used to adjust the touch pressure for the display.

Click the cross

1

1

1. Touch the “cross” symbol on the display as it moves to all 5 positions.

At the end, the Ok icons appears at the corners of the display. Touch it to complete the calibration procedure.

24

Classe 300

Installation Manual

Answering machine (only for item 344622)

This page can be used to set the quality of the videos recorded by the answering machine, or to record, enable, disable the welcome message.

1

Settings Back

Generals

Ringtones

Display

3

Answering machine

Quick Actions

Configuration

Video recording resolution

High

Welcome message

Record message...

2 A

A. Enable/disable the welcome message.

1. Set if video messages must be recorded in high resolution (maximum 25 x 15 sec. messages), or in low resolution (maximum 150 x 15 sec. messages)

2. Touch to record a welcome message.

3. Touch to go back and save the settings.

Warning: the most recent message overwrites the oldest one.

25

Classe 300

Installation Manual

Back

4

Record message

Press to record

4. Touch to start recording, and then record the message.

Back Record message

5

0:20

Press to stop recording

5. Touch to end the recording.

Cancel Record message

6

Save

7

6. Touch to play the message back.

7. Touch to save it.

26

0:20

Press to listen recording

Classe 300

Installation Manual

Quick actions

In this section it is possible to decide which actions to display in home page, selecting them among

the ones available based on the configuration of socket M, tenths (See “Functions of the M tenths configurator (Quick Actions)”)

.

It is also possible to customise the name

A

Back Settings

1

Generals

Ringtones

Display

Answering machine

Quick Actions

Configuration

Pager

Camera 1

Lock 1

Add quick action

B

1. Touch to add a quick action.

A. Change the name of the quick action.

B. Remove the quick action from the home page.

Back

Cameras

Intercom

Activations

Add quick action

Lock 2

Pager

A

2

2. Select the type of function for which you want to add a quick action.

3 Select the quick action among those available.

A. Available quick action.

B. Quick action already included in the home page.

3

B

27

Classe 300

Installation Manual

Back

Cameras

Intercom

Activations

4

Add quick action

Lock 2

Pager

4. Touch to return to the quick action screen and save the settings.

Back Settings

Generals

Ringtones

Display

Answering machine

Quick Actions

Configuration

Pager

Camera 1

Lock 1

Lock 2

5

5. Touch to modify the name.

Back Confirm

Lock 2A

6 q a w

?123

s z e d x r f c t g v y h b u

7 j n i k m

.

o

6. Enter the new name.

7. Touch to save it.

l p

28

Back

Generals

Ringtones

Display

Answering machine

Quick Actions

Configuration

Settings

Pager

Camera 1

Lock 1

Lock 2A

Configuration

Back

Generals

Ringtones

Display

Answering machine

Quick Actions

Configuration

1. Touch to enter the configuration.

Settings

Pager

Camera 1

Lock 1

1

Lock 2A

Classe 300

Installation Manual

29

Classe 300

Installation Manual

This password protected section can be used to make the answering machine and office functions available in the home page, therefore giving the user the possibility of enabling or disabling them.

Back Configuration Confirm

Insert installer password

1 q w e r t a s z d x f c

?123

1. Touch to enter the password (default 12345).

2. Touch to save it.

g v y h b u

2 j n i k m

.

o l p

Back Configuration

3

00

N

00

P

Answering machine

Professional studio

3. Touch to make the function available in the home page.

Warning: Further configurations are also available in the advanced mode , which can only

be used if no configurators have been connected to sockets N-P-M.

30

Classe 300

Installation Manual

Advanced Configuration

The advanced configuration gives the possibility of configuring all the basic settings, the quick actions and the camera, intercom, and activation functions, without being bound to a predefined set.

First switching on

After connecting the device, perform the customisations.

Wait for the LEDS to stop flashing and then touch the display to switch it on.

Languages Next

1

English

Français

Italiano

Español

Deutsch

Néerlandais

Português

2

1. Touch the icon for the desired language.

2. Touch to continue.

Back Time and date Next

4

11 d

11 42 m

10 m

2013 y

3

5

3. Touch the icon for the parameter to set (date or time); the icons to increase or decrease the value appear.

4. Touch to set it.

5. Touch to continue.

31

Classe 300

Installation Manual

Now it is possible to display some information concerning the configuration of the device

Back Info End

A

N

00

P

00

7

Master/Slave

Power supply

Firmware ver.

Professional studio

Answering machine

Configuration

Master

Disabled

1.0.12

Enabled

Enabled

6

Display:

A. The configuration parameters.

B. If the device has been set as apartment master or slave.

C. If an additional power sully is present.

D. The firmware version of the device.

E. If the Professional Studio (Office) function is active.

F. If the Answering machine function is active.

6. Press the End key to go to the home page, postponing the configuration to a later date.

7. Now touch to access the configuration section.

B

C

D

E

F

Back

Generals

Intercom

Camera

Actuation

10

Configuration

00 00

P

Answering machine

Professional studio

9

8

8. Enter the N configurator values to set the address device and enter the P configurator values to set the address of the EP of which you can open the Door Lock with IU idle, and to which you can send the auto-on command.

9. Touch to make the functions available in the home page.

10. Proceed with the advanced configuration, see configuration

section.

32

Classe 300

Installation Manual

10:36

Tuesday, 22 April 11

Answering machine Memo Settings Pager

Lock

11. Touch to proceed with the device customisation in the Settings

section.

Azioni rapide

Private camera

External intercom

33

Classe 300

Installation Manual

Settings

Generals

Ringtones

Time and date/Language/Information/Key tone

Volume/Intercom ringtone/Entrance Panel Ringtone/Other ringtones...

Display

Clean monitor/Background/Calibration

Answering machine

Recording Mode/Welcome Message/Record Message...

For the above mentioned settings, refer to the

Settings section of the physical configuration.

Configuration

General/Intercom/Camera/Activation/Change password

Quick Actions

Add quick action

Configuration

Back Settings

Generals

Ringtones

Display

Answering machine

Quick Actions

Configuration

1

Time and date

Language

Info

Tone buttons

1. Touch to configure the device in advanced mode.

In order to access this section, the password must be entered.

Back Configuration

Insert installer password

Confirm

2 q a w

?123

s z e d x r f c t g v y h b u

3 j n i k m

.

o l p

2. Enter the password (default 12345).

3. Touch to save it.

34

Classe 300

Installation Manual

General settings

Back

Generals

Intercom

Camera

Actuation

Change password

00 00

P

Answering machine

Professional studio

2

1

1. Enter the N configurator values to set the address device and enter the P configurator values to set the address of the EP of which you can open the Door Lock with IU idle, and to which you can send the auto-on command.

2. Touch to make the functions available in the home page.

Intercom

This section can be used to configure the intercoms that will enable the user to communicate with other video/audio handsets installed in the home, or in other apartments, or to use the sound system as a pager, to call people.

Back

Generals

Intercom

Camera

Actuation

Change password

1

00 00

P

Answering machine

Professional studio

1. Touch to enter the Intercom section.

35

Classe 300

Installation Manual

Back

Generals

Intercom

Camera

Actuation

Change password

Add intercom

2

2. Touch to add an intercom.

Back 6 Add intercom

Type

Internal intercom

Description

Internal intercom 0

Address

00

Save

3

4

5

3. Select the type of intercom among:

Internal: it provides communication among rooms of the same apartment (or among devices of different apartments but only if there are no apartment interfaces)

External: it provides communication among rooms of different apartments (if there are apartment interfaces)

Paging: it provides communication with the sound system

General: it provides communication with all internal units

Warning: if no apartment interface has been installed in the system, the call will be made to all residents, otherwise it will remain within the apartment.

4. Change name.

5. Enter address:

Internal: address of the device wired in the same apartment

External: address of another apartment

6. Touch to save.

36

A

Classe 300

Installation Manual

Back

Generals

Intercom

Camera

Actuation

Change password

Add intercom

Internal intercom 0

External intercom 0

Pager 0

General intercom 0

B

A. Change the name of the intercom.

B. Delete intercom.

Camera

This section can be used to configure the cameras that will give users the possibility of displaying the images from their own apartments, the apartment block area, or a CCTV surveillance system.

Back

Generals

Intercom

Camera

Actuation

Change password

00 00

P

Answering machine

Professional studio

1

1. Touch to enter the Camera section.

37

Classe 300

Installation Manual

Back

Generals

Intercom

Camera

Actuation

Change password

Add camera

2

2. Touch to add a camera/entrance panel.

Back 6

Add camera

Type

Private camera

Description

Private camera 0

Address

00

Save

3

5

4

3. Select the type of camera/entrance panel among:

Private: it gives the possibility of displaying the images from a camera/entrance panel installed in the own apartment (if an apartment interface has been installed)

Public: it gives the possibility of displaying the images from a camera/entrance panel installed in a common area, visible to all residents (if an apartment interface has been installed)

Warning: for apartment blocks without apartment interface and in single-family homes, cameras must be considered as PRIVATE.

CCTV: it gives the possibility of displaying the images from a camera of a video video surveillance system integrated with the video door entry SCS system.

The image is displayed for three minutes and the camera cycling is not possible. For the camera cycling or multi-vision functions, connect interface 347400 to a device output (e.g.

Digital Video Recorder) performing these functions.

Warning: to realize this integration, refer to the guides or the diagrams of the SCS/coaxial interface 347400.

38

4. Change name.

5. Enter the address of the camera/entrance panel

6. Touch to save.

Back

Generals

Intercom

Camera

Actuation

Change password

Add camera

Private camera 0

Public camera 0

TVCC 0

A

Classe 300

Installation Manual

B

A. Change the name of the camera/entrance panel.

B. Delete camera/entrance panel.

Activation

In this section it is possible to configure the actuators in your system (e.g. door lock, garden light, etc.) and to activate them for the user.

Back

Generals

Intercom

Camera

Actuation

Change password

00 00

P

Answering machine

1

Professional studio

1. Touch to enter the Activation section.

39

Classe 300

Installation Manual

Back

Generals

Intercom

Canera

Actuation

Change password

Add actuation

2

2. Touch to add an activation.

Back 6

Add actuation

Type

Lock

Description

Address

Lock 0

00

5

3. Select the type of activation among:

Lock: it is possible to activate a door lock actuator

Generic actuator: it is possible to activate a generic actuator

4. Change name.

5. Enter the address of the actuator

6. Touch to save.

4

Save

3

40

A

Classe 300

Installation Manual

Back

Generals

Intercom

Canera

Actuation

Change password

Add actuation

Lock 0

Lock 1

Generic actuator

A. Change the name of the activation.

B. Delete activation.

Change password

In this section it is possible to modify the password used to enter the configuration section.

Back

Generals

Intercom

Camera

Actuation

Change password

00 00

P

Answering machine

Professional studio

1

1. Touch to enter the Change passwors section.

B

41

Classe 300

Installation Manual

Cancel Confirm

New password

Repeat password q a w

?123

s z 3 e d x r f c t g v y h b u j n i

2 k m

.

o l p

1. Enter the new password using the keypad.

2. Repeat the new password.

3. Touch to save it.

Once the system functions have been configured, some can me made available to the users, giving them the possibility of selecting the 4 Quick Actions to display in their home page.

Quick actions

Warning: before using these functions, insert the relevant functions in the “

Configuration ”

section.

Settings Back

Generals

Ringtones

Display

Answering machine

Quick Actions

Configuration

Add quick action

1

1. Touch to add a quick action.

42

Back

Cameras

Intercom

Activations

A

Add quick action

Private camera 0

Public camera

TVCC

Classe 300

Installation Manual

B

2

A. Available Functions.

B. Function already used as quick action.

2. Touch to select the function to be used as quick action.

Back Settings

Generals

Ringtones

Display

Answering machine

Quick Actions

Configuration

Private camera 0

Public camera

Internal intercom

External intercom

It configures up to 4 quick actions.

43

Classe 300

Installation Manual

10:36

Tuesday, 22 April

Answering machine Cameras Memo

Quick Actions

Private camera

Public camera

Internal intercom

Intercom Activations Settings

External intercom

Now the quick actions appear in the home page.

Factory configuration

– Beep: OFF

– Professional Studio (Office): OFF

– Type of ringtone:

Main Entrance Panel S0 = 2

Secondary Entrance Panel S1 = 11

Secondary Entrance Panel S2 = 5

Secondary Entrance Panel S3 = 4

Floor call = 7

Notifications=13

Internal intercom = 1

External intercom = 16

– Default background: Home

– Installer password: 12345

(Note: the password must have 5 alphanumeric digits and can manage lower case and upper case)

Model 344622 only

– Answering machine ENABLED but NOT ACTIVE

– Active movies in high resolution

Device potential

– Memory and memos:

(Model 344622 only) 25 x 15” high resolution movies (warning, when the maximum limit is reached, the most recent overwrites the oldest one)

(Model 344622 only) 150 x 15” low resolution movies (warning, when the maximum limit is reached, the most recent overwrites the oldest one)

20 audio memos (warning: when the maximum limit is reached, the most recent overwrites the oldest one)

50 written memos (warning: when the maximum limit is reached, the most recent overwrites the oldest one)

– Configurable controls:

Max. No. of door locks: 50

Max. No. of generic activations: 50

Max. No. of direct activations: 50

Max. No. of internal intercoms: 40

Max. No. of external intercoms: 40