Bticino 344612 manual
Bticino 344612 is a technologically advanced video internal unit for 2-wire digital systems with a 7" touch screen display. It enables users to manage video door entry calls, communicate with other internal units, activate actuators, and utilize various functions through its intuitive interface. With its modern design and compact size, it seamlessly integrates into any home or office environment.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
www.bticino.com
Classe 300
Installation Manual
Classe 300
Installation Manual
Contents
Classe 300
Installation Manual
Dimensional data and installation heights
Installation on the table-top base
Functions of the M units configurator (Favorites key)
Functions of the M tenths configurator (Quick actions)
Answering machine (only for item 344622)
3
Classe 300
Installation Manual
16
15
14
General information
Warnings and recommendations
It is important to read this manual carefully before proceeding with the installation.
The guarantee automatically expires for negligence, misuse, tampering by unauthorized personnel.
The Classe 300 Video internal unit must only be installed indoors; it must not be exposed to water drops or splashes; it must be used only on BTicino 2 wire digital systems.
Front view
1 2 3 4 5 6 7
10:36
Tuesday, 22 April
17
Answering machine Cameras Memo
Intercom Activations Settings
Quick Actions
Private camera
External intercom
Pager
Lock
8
9 13 12 11 10
The image shows the device with all its functions enabled.
Check on the installer manual how to enable the functions.
1. 7” touch screen display (16 : 9)
2. Screen OFF key
3. Time and date
4. Ringtone exclusion
5. Professional Studio (Office) activation
6. Microphone
7. Answering machine activation (only models 344622)
8. Quick actions
9. Tactile guides
10. Connection key:
The green LED flashes to indicate an incoming call
The green LED comes on steady to indicate that there is an active call
11. Auto-switching on/Scrolling: the red LED turns on when the key is pressed
9
4
Classe 300
Installation Manual
12. Favorites key: the red LED turns on when the key is pressed
(Basic configuration = STAIRCASE LIGHT. For a different configuration refer to the physical configuration
)
13. Door lock release key: the red LED turns on when the key is pressed
14. Answering machine Status (only models 344622):
Red LED steady = answering machine active
Red LED flashing = new recording/s
15. Message status:
Red LED flashing = new unread note/s
16. Bell exclusion Status:
Red LED on = Call ringtone disabled
17. Functions (only the icons for the configured functions are displayed)
5
Classe 300
Installation Manual
Rear view
1 2 3
6
10 9 8 7
1. Configurator socket
2. Configurator J1: remove for additional power supply
3. J2 configurator: Master/Slave, remove for Slave
4. Line termination ON/OFF micro-switch
5. Mini USB socket for device Firmware update using the MyHomeSuite software
Note: the device must be powered (1-2 or BUS)
6. Loudspeaker
7. Additional power supply clamps (1 - 2)
8. 2 WIRE SCS/BUS connection clamps
9. Clamps ( ) for the connection of an external call to the floor pushbutton
10. Additional ringtone connection clamps (1 - 5M)
Point-to-Point connections are required on the clamps of the additional ringtones
6
4
5
6
Dimensional data and installation heights
194 mm
10:36
Tuesday, 22 April
Answering machine Cameras Memo
Intercom Activations Settings
Quick Actions
Private camera
External intercom
Pager
Lock
Classe 300
Installation Manual
25 mm
Height recommended, unless otherwise required by the law
7
Classe 300
Installation Manual
Wall-mounted installation
1
3
8
4
2
Installation on the table-top base
Classe 300
Installation Manual
Warning: position the microswitch on ON to terminate the line.
10:
Tue sda
36 y, 2
2 A pril
An sweri ng m ach ine
Cam era s
Act ivat ions
Mem o s
Qu ick
Ac tion
Priv ate
cam era
Exte rna l inte rco m
Pag er
Lock
Set ting s
Inte rco m
8-way socket:
336982/83/84 Livinglight
349414/15/18 Axolute
5 6
7
8
5 6
7
8
1-2
1-2
3
4
1
2
7
8
5
6 3
4
1
2
7
8
5
6
BUS
BUS
9
Classe 300
Installation Manual
Physical configuration
The device must be configured both physically or in
advanced mode , the main differences are
shown in the following table:
Warning: the connection of the configurators to the N - P - M sockets precludes the possibility of using the advanced configuration.
The configuration must be performed with the device disconnected from the power supply.
Before using it, wait for the LEDs to stop flashing.
Available Functions
FAVORITES KEY
QUICK ACTIONS
Private camera
External intercom
Physical Configuration
Possibility of assigning various functions
See “Functions of the M units configurator (Favorites key)”
Preset:
See “Functions of the M tenths configurator (Quick actions)”
The user can rename, delete and add back, only the preset functions
Advanced Configuration
Staircase Light function
Creating quick actions of all functions
The user can decide the quick actions to display in the home page
Pager
Lock
FUNCTIONS The use of the functions is only available through quick actions in the home page
See “Functions of the M tenths configurator (Quick actions)”
Dedicated icons in the home page and customisable, configurable functions
Cameras
Intercom
Activations
10
Classe 300
Installation Manual
Configurators
1 2 3
J1 J2 N
4
P
5
M
Configurator functions
1. J1 = Remove if the additional power supply is present (clamp 1 – 2)
2. J2 = Master/Slave (remove for slave)
3. NN = Device address
4. PP = Address of the EP of which you can open the Door Lock with IU idle, and to which you can send the auto-on command
5. MM = Mode of operation according to the tables on the following pages
M units = Configuration of the FAVORITES capacitive key
M tenths = Configuration of the QUICK ACTIONS in the Home page
If the device is configured physically, the configuration MUST NOT BE MODIFIED using the menu.
11
Classe 300
Installation Manual
Functions of the M units configurator (Favorites key)
J1 J2 N
MM = 0
MM = 1
MM = 2
MM = 3
P M
Staircase Light Control
Direct control of P+1 Door lock
Direct control of P+2 Door lock
Direct control of P+3 Door lock
MM = 4
MM = 5
MM = 6
MM = 7
P+1 direct auto-switching on
P+2 direct auto-switching on
P+3 direct auto-switching on
General Intercom
MM = 8 Internal intercom
MM = 9
Enabling/disabling Professional Studio (Office) function
12
P
P
P+1
P+1
MOD=9
P +2
P+2
P+2
MOD=9
P +3
P+3
P+3
MOD=9
P+1
346210
346210
346210
P+1 P+1
P+1 P+1
MOD=5
P+2
346210
346210
346210
P+2 P+2
P+2 P+2
MOD=5
P+3
346210
346210
346210
P+3 P+3
P+3 P+3
MOD=5
P
P
346210
P
P +1
P
+1
P+1
MOD=9
P+1
MOD=9
P +1
P +2
P +2
MOD=9
P+2
MOD=9
P+2
346210 MOD=9
P +2
P +3
P +3
P +3
MOD=9
P+3
MOD=9
P+3
MOD=9
P+3
MOD=9
Classe 300
Installation Manual
Functions of the M tenths configurator (Quick actions)
The MM - (tenths) physical configurator decides which are the 4 QUICK ACTIONS icons that appear
on the HOME PAGE, and can be activated by touching the display.
J1 J2
P
P
P
P
N
–+ 23
P M
P
P
P
P
+1
+1
+1
+1
–+ 23 P+1
–+ 23 MOD=9
–+ MOD=9 23 P+1
P+1
MOD=9
–+ 23
The possible configurations are shown in the following table
P
P
P +2
–+
–+
23 MOD=9
23 MOD=9
P+2
MOD=9
P
P
P
+3
+3
+3
346210
–+ 23
–+ 23 P+3
MOD=9
MOD=9
P+3
MOD=9
Activation of the EP (configured with P+1) directly without call or activation of the actuator item 346200/346210 (configured with P+1 and
MOD=9).
–+ 23
P +2
346210
346210
P+1
P+1
P+1
P+1
23
346210
EP door lock release (configured with P+1), directly without call, or activation of the actuator item 346200/346210 (configured with P+1 and
MOD=5), or activation of door lock actuators item 346230 (configured with P+1)
P 346210 +3
MOD=5
MOD=5
346210
P+2
P+2
P+2
P+1
346210
P+2
P+2 P+2
MOD=5
MOD=5
P+2 P+2
MOD=5
P+3
P+3
346210
346210
P+3
346210 MOD=5
346210
P+3 P+3
MOD=5
MOD=5
346210
P+4
P+4
P+3
346210
P+4
P+4
P+4 P+4
MOD=5
P+4 P+4
MOD=5
MOD=5
EP door lock release (configured with P+2), directly without call, or activation of the actuator item 346200/346210 (configured with P+2 and
MOD=5), or activation of door lock actuators item 346230 (configured with P+2)
EP door lock release (configured with P+3), directly without call, or activation of the actuator item 346200/346210 (configured with P+3 and
MOD=5), or activation of door lock actuators item 346230 (configured with P+3)
EP door lock release (configured with P+4), directly without call, or activation of the actuator item 346200/346210 (configured with P+4 and
MOD=5), or activation of door lock actuators item 346230 (configured with P+4)
P+4
346210
P+4 P+4
MOD=5
Intercom among apartments in systems with apartment interface item
346850.
Intercom inside the apartment, in systems with apartment interface item
346850, or intercom among apartments in systems without apartment interface.
Internal intercom. It sends the call to all the handsets with the same address.
General intercom. It sends the call to all the handsets of the system.
13
Classe 300
Installation Manual
P
0 1
M
Myself
Poste externe 1
Lock 1
Lock 2
Pager
Camera 1
Lock 1
Lock 2
P
0 2
M P
0 3
M
Myself
Intercom 1
Camera 1
Lock 1
346210
P +1 P+1
MOD=9
P+1
346210
P+1 P+1
MOD=5
P+2
346210
P+2 P+2
MOD=5
346210
P +1 P+1
MOD=9
P+1
346210
P+1 P+1
MOD=5
P+2
346210
P+2 P+2
MOD=5
N=1 N=2
N=2 N=1
346210
P +1 P+1
MOD=9
P+1
346210
P+1 P+1
MOD=5
14
P+1
346210
P+1 P+1
MOD=5
P+2
346210
P+2 P+2
MOD=5
P
0 4
M
Intercom 2
Intercom 3
Lock 1
Lock 2
N=1 N=3
N=2
N=2 N=3
N=1
N=3 N=2
N=1
P+1
346210
P+1 P+1
MOD=5
P+2
346210
P+2 P+2
MOD=5
P
0 5
M
Intercom 2
Intercom 3
Lock 1
Lock 2
N=1
N=2
N=3
N=2
N=1
N=3
N=3
N=1
N=2
N=2 N=1 N=4
N=3 N=5
N=3 N=1 N=4
N=2 N=5
N=4 N=1 N=3
N=2 N=5
N=5 N=1 N=3
N=2 N=4
Classe 300
Installation Manual
P
0 6
M
Intercom 2
Intercom 3
Intercom 4
Intercom 5
N=1 N=2 N=3
N=4 N=5
15
Classe 300
Installation Manual
N=2 N=1 N=4
N=3 N=5
N=3 N=1 N=4
N=2 N=5
N=4 N=1 N=3
N=2 N=5
P
0 7
M
Intercom 2
Intercom 3
Intercom 4
Intercom 5
N=1 N=2 N=3
N=4 N=5
P
0 8
M
Camera 1
Intercom 1
Lock 1
Lock 2
346210
P +1 P+1
MOD=9
N=1 N=2
N=2 N=1
P+1
346210
P+1 P+1
MOD=5
P+2
346210
P+2 P+2
MOD=5
P+3
346210
P+3 P+3
MOD=5
P+4
346210
P+4 P+4
MOD=5
Lock 1
Lock 2
Lock 3
Lock 4
P
0 9
M
P+1
346210
P+1 P+1
MOD=5
P+2
346210
P+2 P+2
MOD=5
16
Classe 300
Installation Manual
First switching on
After the device has been configured physically and connected, it is mandatory to perform the customisations using the menu.
Wait for the LEDS to stop flashing and then touch the display to switch it on.
Languages Next
1
English
Français
Italiano
Español
Deutsch
Néerlandais
Português
2
1. Touch the icon for the desired language.
2. Touch to continue.
Back Time and date Next
4
11 d
11 42 m
10 m
2013 y
3
5
3. Touch the icon for the parameter to set (date or time); the icons to increase or decrease the value appear.
4. Touch to set it.
5. Touch to continue.
17
Classe 300
Installation Manual
Now it is possible to display information concerning the configuration of the device
Back
6
Info
N
00
P
00
Master/Slave
Power supply
Firmware ver.
Professional studio
Answering machine
Master
Disabled
1.0.12
Enabled
Enabled
M
20
Display:
A. The configuration parameters.
B. If the device has been set as apartment master or slave.
C. If an additional power sully is present.
D. The firmware version of the device.
E. If the Professional Studio (Office)
function is active.
function is active (only for item 344622).
6. Touch to end the procedure.
End
10:36
Tuesday, 22 April 7
Quick Actions
Pager
Camera 1
Answering machine Memo Settings Lock 1
Lock 2
7. Touch to proceed with the device customisation in the Settings
section.
A
B
C
D
E
F
18
Classe 300
Installation Manual
Settings
Generals
Ringtones
Display
Answering machine
Quick Actions
Configuration
Time and date/Language/Information/Key tone
Volume/Intercom ringtone/Entrance Panel Ringtone/Other ringtones...
Clean monitor/Background/Calibration
Recording Mode/Welcome Message/Record Message...
Activation of Answering machine/ Professional Studio (Office)
General settings
This section contains the general settings and device information.
Back Settings
Generals
Ringtones
Display
Answering machine
Quick Actions
Configuration
Time and date
Language
Info
Tone buttons A
A. Enable/disable the sound when a key is pressed.
19
Classe 300
Installation Manual
Time and date
Set the current time and date.
Back Time and date
2
11 d
11 42 m
10 m
2013 y
1
1. Touch the icon for the parameter to set; the icons to increase or decrease the value appear.
2. Touch to set it.
Language
Set the device language.
Back Languages
English
Français
Italiano
Español
Deutsch
Néerlandais
Português
1
1. Touch the icon for the desired language.
20
Classe 300
Installation Manual
Information
It displays information concerning the configuration of the device.
Back Info
N
00
P
00
Master/Slave
Power supply
Firmware ver.
Professional studio
Answering machine
Master
Disabled
1.0.12
Enabled
Enabled
M
00
1
End
Display:
A. The configuration parameters.
B. If the device has been set as apartment master or slave.
C. If an additional power sully is present.
D. The firmware version of the device.
E. If the Professional Studio (Office)
function is active.
function is active (only for item 344622).
1. Touch to go back and save the settings.
A
B
C
D
E
F
21
Classe 300
Installation Manual
Ringtones
This section can be used to associate specific ringtones to certain events, and to adjust their volume.
Back Settings
A
Volume
Generals
Ringtones
Answering machine
Quick Actions
Configuration
Main entrance panel
16
Internal intercom
1
1
More ringtones...
2
A. Adjust the ringtone volume.
1. Touch the event box to which to associate a specific ringtone; the selection arrows appear.
2. Scroll through the available ringtones (16); they will be played back as you scroll through them.
3. Touch to go back and save the settings.
Events to which it is possible to associate ringtones:
Main Entrance Panel: call from the main entrance panel (S0)
Internal intercom: call from an intercom in your apartment.
Other ringtones...
S1, 2, 3 Entrance Panel: call from the SECONDARY Entrance Panel (S1; S2; S3)
External intercom: call from an intercom of another apartment.
Call to the floor: call from the pushbutton outside your entrance door.
Notifications: memo from the switchboard.
22
Classe 300
Installation Manual
Display
This section is used to calibrate, clean the monitor, and to change the background image.
Back Settings
Generals
Ringtones
Display
Answering machine
Quick Actions
Configuration
Clean monitor
Background
Calibration
Clean monitor
It’s used to disable the display and the keys for cleaning purposes, without the risk of sending unwanted commands.
A
10
1
A. After touching the corresponding icon, the display remains in stand-by for 10 seconds.
1. during this period, it is possible to clean the monitor and the keys.
Caution: do not clean with solvents, thinners etc. or abrasive products. Only use a soft cloth.
23
Classe 300
Installation Manual
Background
It gives the possibility to change the background image of the device.
Back
Background
2 home
1. Scroll through the available images to get a background preview.
2. Touch to go back and save the settings.
Calibration
It can be used to adjust the touch pressure for the display.
Click the cross
1
1
1. Touch the “cross” symbol on the display as it moves to all 5 positions.
At the end, the Ok icons appears at the corners of the display. Touch it to complete the calibration procedure.
24
Classe 300
Installation Manual
Answering machine (only for item 344622)
This page can be used to set the quality of the videos recorded by the answering machine, or to record, enable, disable the welcome message.
1
Settings Back
Generals
Ringtones
Display
3
Answering machine
Quick Actions
Configuration
Video recording resolution
High
Welcome message
Record message...
2 A
A. Enable/disable the welcome message.
1. Set if video messages must be recorded in high resolution (maximum 25 x 15 sec. messages), or in low resolution (maximum 150 x 15 sec. messages)
2. Touch to record a welcome message.
3. Touch to go back and save the settings.
Warning: the most recent message overwrites the oldest one.
25
Classe 300
Installation Manual
Back
4
Record message
Press to record
4. Touch to start recording, and then record the message.
Back Record message
5
0:20
Press to stop recording
5. Touch to end the recording.
Cancel Record message
6
Save
7
6. Touch to play the message back.
7. Touch to save it.
26
0:20
Press to listen recording
Classe 300
Installation Manual
Quick actions
In this section it is possible to decide which actions to display in home page, selecting them among
.
It is also possible to customise the name
A
Back Settings
1
Generals
Ringtones
Display
Answering machine
Quick Actions
Configuration
Pager
Camera 1
Lock 1
Add quick action
B
1. Touch to add a quick action.
A. Change the name of the quick action.
B. Remove the quick action from the home page.
Back
Cameras
Intercom
Activations
Add quick action
Lock 2
Pager
A
2
2. Select the type of function for which you want to add a quick action.
3 Select the quick action among those available.
A. Available quick action.
B. Quick action already included in the home page.
3
B
27
Classe 300
Installation Manual
Back
Cameras
Intercom
Activations
4
Add quick action
Lock 2
Pager
4. Touch to return to the quick action screen and save the settings.
Back Settings
Generals
Ringtones
Display
Answering machine
Quick Actions
Configuration
Pager
Camera 1
Lock 1
Lock 2
5
5. Touch to modify the name.
Back Confirm
Lock 2A
6 q a w
?123
s z e d x r f c t g v y h b u
7 j n i k m
.
o
6. Enter the new name.
7. Touch to save it.
l p
28
Back
Generals
Ringtones
Display
Answering machine
Quick Actions
Configuration
Settings
Pager
Camera 1
Lock 1
Lock 2A
Configuration
Back
Generals
Ringtones
Display
Answering machine
Quick Actions
Configuration
1. Touch to enter the configuration.
Settings
Pager
Camera 1
Lock 1
1
Lock 2A
Classe 300
Installation Manual
29
Classe 300
Installation Manual
This password protected section can be used to make the answering machine and office functions available in the home page, therefore giving the user the possibility of enabling or disabling them.
Back Configuration Confirm
Insert installer password
1 q w e r t a s z d x f c
?123
1. Touch to enter the password (default 12345).
2. Touch to save it.
g v y h b u
2 j n i k m
.
o l p
Back Configuration
3
00
N
00
P
Answering machine
Professional studio
3. Touch to make the function available in the home page.
Warning: Further configurations are also available in the advanced mode , which can only
be used if no configurators have been connected to sockets N-P-M.
30
Classe 300
Installation Manual
Advanced Configuration
The advanced configuration gives the possibility of configuring all the basic settings, the quick actions and the camera, intercom, and activation functions, without being bound to a predefined set.
First switching on
After connecting the device, perform the customisations.
Wait for the LEDS to stop flashing and then touch the display to switch it on.
Languages Next
1
English
Français
Italiano
Español
Deutsch
Néerlandais
Português
2
1. Touch the icon for the desired language.
2. Touch to continue.
Back Time and date Next
4
11 d
11 42 m
10 m
2013 y
3
5
3. Touch the icon for the parameter to set (date or time); the icons to increase or decrease the value appear.
4. Touch to set it.
5. Touch to continue.
31
Classe 300
Installation Manual
Now it is possible to display some information concerning the configuration of the device
Back Info End
A
N
00
P
00
7
Master/Slave
Power supply
Firmware ver.
Professional studio
Answering machine
Configuration
Master
Disabled
1.0.12
Enabled
Enabled
6
Display:
A. The configuration parameters.
B. If the device has been set as apartment master or slave.
C. If an additional power sully is present.
D. The firmware version of the device.
E. If the Professional Studio (Office) function is active.
F. If the Answering machine function is active.
6. Press the End key to go to the home page, postponing the configuration to a later date.
7. Now touch to access the configuration section.
B
C
D
E
F
Back
Generals
Intercom
Camera
Actuation
10
Configuration
00 00
P
Answering machine
Professional studio
9
8
8. Enter the N configurator values to set the address device and enter the P configurator values to set the address of the EP of which you can open the Door Lock with IU idle, and to which you can send the auto-on command.
9. Touch to make the functions available in the home page.
10. Proceed with the advanced configuration, see configuration
section.
32
Classe 300
Installation Manual
10:36
Tuesday, 22 April 11
Answering machine Memo Settings Pager
Lock
11. Touch to proceed with the device customisation in the Settings
section.
Azioni rapide
Private camera
External intercom
33
Classe 300
Installation Manual
Settings
Generals
Ringtones
Time and date/Language/Information/Key tone
Volume/Intercom ringtone/Entrance Panel Ringtone/Other ringtones...
Display
Clean monitor/Background/Calibration
Answering machine
Recording Mode/Welcome Message/Record Message...
For the above mentioned settings, refer to the
Settings section of the physical configuration.
Configuration
General/Intercom/Camera/Activation/Change password
Quick Actions
Configuration
Back Settings
Generals
Ringtones
Display
Answering machine
Quick Actions
Configuration
1
Time and date
Language
Info
Tone buttons
1. Touch to configure the device in advanced mode.
In order to access this section, the password must be entered.
Back Configuration
Insert installer password
Confirm
2 q a w
?123
s z e d x r f c t g v y h b u
3 j n i k m
.
o l p
2. Enter the password (default 12345).
3. Touch to save it.
34
Classe 300
Installation Manual
General settings
Back
Generals
Intercom
Camera
Actuation
Change password
00 00
P
Answering machine
Professional studio
2
1
1. Enter the N configurator values to set the address device and enter the P configurator values to set the address of the EP of which you can open the Door Lock with IU idle, and to which you can send the auto-on command.
2. Touch to make the functions available in the home page.
Intercom
This section can be used to configure the intercoms that will enable the user to communicate with other video/audio handsets installed in the home, or in other apartments, or to use the sound system as a pager, to call people.
Back
Generals
Intercom
Camera
Actuation
Change password
1
00 00
P
Answering machine
Professional studio
1. Touch to enter the Intercom section.
35
Classe 300
Installation Manual
Back
Generals
Intercom
Camera
Actuation
Change password
Add intercom
2
2. Touch to add an intercom.
Back 6 Add intercom
Type
Internal intercom
Description
Internal intercom 0
Address
00
Save
3
4
5
3. Select the type of intercom among:
Internal: it provides communication among rooms of the same apartment (or among devices of different apartments but only if there are no apartment interfaces)
External: it provides communication among rooms of different apartments (if there are apartment interfaces)
Paging: it provides communication with the sound system
General: it provides communication with all internal units
Warning: if no apartment interface has been installed in the system, the call will be made to all residents, otherwise it will remain within the apartment.
4. Change name.
5. Enter address:
Internal: address of the device wired in the same apartment
External: address of another apartment
6. Touch to save.
36
A
Classe 300
Installation Manual
Back
Generals
Intercom
Camera
Actuation
Change password
Add intercom
Internal intercom 0
External intercom 0
Pager 0
General intercom 0
B
A. Change the name of the intercom.
B. Delete intercom.
Camera
This section can be used to configure the cameras that will give users the possibility of displaying the images from their own apartments, the apartment block area, or a CCTV surveillance system.
Back
Generals
Intercom
Camera
Actuation
Change password
00 00
P
Answering machine
Professional studio
1
1. Touch to enter the Camera section.
37
Classe 300
Installation Manual
Back
Generals
Intercom
Camera
Actuation
Change password
Add camera
2
2. Touch to add a camera/entrance panel.
Back 6
Add camera
Type
Private camera
Description
Private camera 0
Address
00
Save
3
5
4
3. Select the type of camera/entrance panel among:
Private: it gives the possibility of displaying the images from a camera/entrance panel installed in the own apartment (if an apartment interface has been installed)
Public: it gives the possibility of displaying the images from a camera/entrance panel installed in a common area, visible to all residents (if an apartment interface has been installed)
Warning: for apartment blocks without apartment interface and in single-family homes, cameras must be considered as PRIVATE.
CCTV: it gives the possibility of displaying the images from a camera of a video video surveillance system integrated with the video door entry SCS system.
The image is displayed for three minutes and the camera cycling is not possible. For the camera cycling or multi-vision functions, connect interface 347400 to a device output (e.g.
Digital Video Recorder) performing these functions.
Warning: to realize this integration, refer to the guides or the diagrams of the SCS/coaxial interface 347400.
38
4. Change name.
5. Enter the address of the camera/entrance panel
6. Touch to save.
Back
Generals
Intercom
Camera
Actuation
Change password
Add camera
Private camera 0
Public camera 0
TVCC 0
A
Classe 300
Installation Manual
B
A. Change the name of the camera/entrance panel.
B. Delete camera/entrance panel.
Activation
In this section it is possible to configure the actuators in your system (e.g. door lock, garden light, etc.) and to activate them for the user.
Back
Generals
Intercom
Camera
Actuation
Change password
00 00
P
Answering machine
1
Professional studio
1. Touch to enter the Activation section.
39
Classe 300
Installation Manual
Back
Generals
Intercom
Canera
Actuation
Change password
Add actuation
2
2. Touch to add an activation.
Back 6
Add actuation
Type
Lock
Description
Address
Lock 0
00
5
3. Select the type of activation among:
Lock: it is possible to activate a door lock actuator
Generic actuator: it is possible to activate a generic actuator
4. Change name.
5. Enter the address of the actuator
6. Touch to save.
4
Save
3
40
A
Classe 300
Installation Manual
Back
Generals
Intercom
Canera
Actuation
Change password
Add actuation
Lock 0
Lock 1
Generic actuator
A. Change the name of the activation.
B. Delete activation.
Change password
In this section it is possible to modify the password used to enter the configuration section.
Back
Generals
Intercom
Camera
Actuation
Change password
00 00
P
Answering machine
Professional studio
1
1. Touch to enter the Change passwors section.
B
41
Classe 300
Installation Manual
Cancel Confirm
New password
Repeat password q a w
?123
s z 3 e d x r f c t g v y h b u j n i
2 k m
.
o l p
1. Enter the new password using the keypad.
2. Repeat the new password.
3. Touch to save it.
Once the system functions have been configured, some can me made available to the users, giving them the possibility of selecting the 4 Quick Actions to display in their home page.
Quick actions
Warning: before using these functions, insert the relevant functions in the “
section.
Settings Back
Generals
Ringtones
Display
Answering machine
Quick Actions
Configuration
Add quick action
1
1. Touch to add a quick action.
42
Back
Cameras
Intercom
Activations
A
Add quick action
Private camera 0
Public camera
TVCC
Classe 300
Installation Manual
B
2
A. Available Functions.
B. Function already used as quick action.
2. Touch to select the function to be used as quick action.
Back Settings
Generals
Ringtones
Display
Answering machine
Quick Actions
Configuration
Private camera 0
Public camera
Internal intercom
External intercom
It configures up to 4 quick actions.
43
Classe 300
Installation Manual
10:36
Tuesday, 22 April
Answering machine Cameras Memo
Quick Actions
Private camera
Public camera
Internal intercom
Intercom Activations Settings
External intercom
Now the quick actions appear in the home page.
Factory configuration
– Beep: OFF
– Professional Studio (Office): OFF
– Type of ringtone:
Main Entrance Panel S0 = 2
Secondary Entrance Panel S1 = 11
Secondary Entrance Panel S2 = 5
Secondary Entrance Panel S3 = 4
Floor call = 7
Notifications=13
Internal intercom = 1
External intercom = 16
– Default background: Home
– Installer password: 12345
(Note: the password must have 5 alphanumeric digits and can manage lower case and upper case)
Model 344622 only
– Answering machine ENABLED but NOT ACTIVE
– Active movies in high resolution
Device potential
– Memory and memos:
(Model 344622 only) 25 x 15” high resolution movies (warning, when the maximum limit is reached, the most recent overwrites the oldest one)
(Model 344622 only) 150 x 15” low resolution movies (warning, when the maximum limit is reached, the most recent overwrites the oldest one)
20 audio memos (warning: when the maximum limit is reached, the most recent overwrites the oldest one)
50 written memos (warning: when the maximum limit is reached, the most recent overwrites the oldest one)
– Configurable controls:
Max. No. of door locks: 50
Max. No. of generic activations: 50
Max. No. of direct activations: 50
Max. No. of internal intercoms: 40
Max. No. of external intercoms: 40
Warning: for the maximum number of devices and their configuration on the system, always refer to the technical guide.
44
45
Classe 300
Installation Manual
BTicino SpA
Viale Borri, 231
21100 Varese www.bticino.com
BTicino Spa reserves at any time the right to modify the contents of this booklet and to communicate, in any form and modality, the changes brought to the same.
advertisement
Related manuals
advertisement
Table of contents
- 4 General information
- 4 Warnings and recommendations
- 4 Front view
- 6 Rear view
- 7 Dimensional data and installation heights
- 8 Wall-mounted installation
- 9 Installation on the table-top base
- 10 Physical configuration
- 11 Configurators
- 12 Functions of the M units configurator (Favorites key)
- 13 Functions of the M tenths configurator (Quick actions)
- 17 First switching on
- 19 Settings
- 19 General settings
- 22 Ringtones
- 23 Display
- 25 Answering machine (only for item 344622)
- 27 Quick actions
- 29 Configuration
- 31 Advanced Configuration
- 31 First switching on
- 34 Configuration
- 35 General settings
- 35 Intercom
- 37 Camera
- 39 Activation
- 41 Change password
- 42 Quick actions
- 44 Factory configuration