DAIKIN R410A Split Series FTX20KV1B, FTX25KV1B, FTX35KV1B, FTX50KV1B, FTX60KV1B split-system air conditioner Installation manual
Below you will find brief information for R410A Split Series FTX20KV1B, R410A Split Series FTX25KV1B, R410A Split Series FTX35KV1B, R410A Split Series FTX50KV1B. This manual provides detailed instructions on how to install your new DAIKIN split-system air conditioner. You will find information on choosing the right location for your indoor and outdoor units, connecting the refrigerant piping, completing the wiring and drain piping, and finally performing a trial operation and testing.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
English INSTALLATION MANUAL Deutsch DAIKIN ROOM AIR CONDITIONER Pyccкий FTX20KV1B FTX25KV1B FTX35KV1B FTX50KV1B FTX60KV1B Türkçe MODELS Portugues Eλληνικά Italiano Español Nederlands Français R410A Split Series CE - DECLARACION-DE-CONFORMIDAD CE - DICHIARAZIONE-DI-CONFORMITA CE - ∆HΛΩΣΗ ΣΥΜΜΟΡΦΩΣΗΣ 10 09 08 07 19 ob upoštevanju določb: 20 vastavalt nõuetele: 21 следвайки клаузите на: 22 laikantis nuostatų, pateikiamų: 23 ievērojot prasības, kas noteiktas: 24 održiavajúc ustanovenia: 25 bunun koşullarına uygun olarak: 07 ** 08 ** 09 ** 10 ** 11 ** 12 ** 11 Information * enligt <A> och godkänts av <B> enligt Certifikatet <C>. 12 Merk * som det fremkommer i <A> og gjennom positiv bedømmelse av <B> ifølge Sertifikat <C>. 13 Huom * jotka on esitetty asiakirjassa <A> ja jotka <B> on hyväksynyt Sertifikaatin <C> mukaisesti. 14 Poznámka * jak bylo uvedeno v <A> a pozitivně zjištěno <B> v souladu s osvědčením <C>. 15 Napomena * kako je izloženo u <A> i pozitivno ocijenjeno od strane <B> prema Certifikatu <C>. Takayuki Fujii Managing Director Pilsen, 1st of Dec. 2014 13 ** 14 ** 15 ** 16 ** 17 ** 18 ** CE - ATITIKTIES-DEKLARACIJA CE - ATBILSTĪBAS-DEKLARĀCIJA CE - VYHLÁSENIE-ZHODY CE - UYGUNLUK-BEYANI DICz*** on valtuutettu laatimaan Teknisen asiakirjan. Společnost DICz*** má oprávnění ke kompilaci souboru technické konstrukce. DICz*** je ovlašten za izradu Datoteke o tehničkoj konstrukciji. A DICz*** jogosult a műszaki konstrukciós dokumentáció összeállítására. DICz*** ma upoważnienie do zbierania i opracowywania dokumentacji konstrukcyjnej. DICz*** este autorizat să compileze Dosarul tehnic de construcţie. 19 ** 20 ** 21 ** 22 ** 23 ** 24 ** 25 ** DEKRA (NB0344) 74736-KRQ/EMC97-4957 <C> DAIKIN.TCF.015R3/11-2014 DAIKIN.TCF.015R4/12-2014 <B> <A> 19 Direktive z vsemi spremembami. 20 Direktiivid koos muudatustega. 21 Директиви, с техните изменения. 22 Direktyvose su papildymais. 23 Direktīvās un to papildinājumos. 24 Smernice, v platnom znení. 25 Deǧiştirilmiş halleriyle Yönetmelikler. DICz*** je pooblaščen za sestavo datoteke s tehnično mapo. DICz*** on volitatud koostama tehnilist dokumentatsiooni. DICz*** е оторизирана да състави Акта за техническа конструкция. DICz*** yra įgaliota sudaryti šį techninės konstrukcijos failą. DICz*** ir autorizēts sastādīt tehnisko dokumentāciju. Spoločnosť DICz*** je oprávnená vytvoriť súbor technickej konštrukcie. DICz*** Teknik Yapı Dosyasını derlemeye yetkilidir. 21 Забележка * както е изложено в <A> и оценено положително от <B> съгласно Сертификата <C>. 22 Pastaba * kaip nustatyta <A> ir kaip teigiamai nuspręsta <B> pagal Sertifikatą <C>. 23 Piezīmes * kā norādīts <A> un atbilstoši <B> pozitīvajam vērtējumam saskaņā ar sertifikātu <C>. 24 Poznámka * ako bolo uvedené v <A> a pozitívne zistené <B> v súlade s osvedčením <C>. 25 Not * <A>’da belirtildiği gibi ve <C> Sertifikasına göre <B> tarafından olumlu olarak değerlendirildiği gibi. 10 Direktiver, med senere ændringer. 11 Direktiv, med företagna ändringar. 12 Direktiver, med foretatte endringer. 13 Direktiivejä, sellaisina kuin ne ovat muutettuina. 14 v platném znění. 15 Smjernice, kako je izmijenjeno. 16 irányelv(ek) és módosításaik rendelkezéseit. 17 z późniejszymi poprawkami. 18 Directivelor, cu amendamentele respective. 16 megfelelnek az alábbi szabvány(ok)nak vagy egyéb irányadó dokumentum(ok)nak, ha azokat előírás szerint használják: 17 spełniają wymogi następujących norm i innych dokumentów normalizacyjnych, pod warunkiem że używane są zgodnie z naszymi instrukcjami: 18 sunt în conformitate cu următorul (următoarele) standard(e) sau alt(e) document(e) normativ(e), cu condiţia ca acestea să fie utilizate în conformitate cu instrucţiunile noastre: 19 skladni z naslednjimi standardi in drugimi normativi, pod pogojem, da se uporabljajo v skladu z našimi navodili: 20 on vastavuses järgmis(t)e standardi(te)ga või teiste normatiivsete dokumentidega, kui neid kasutatakse vastavalt meie juhenditele: 21 съответстват на следните стандарти или други нормативни документи, при условие, че се използват съгласно нашите инструкции: 22 atitinka žemiau nurodytus standartus ir (arba) kitus norminius dokumentus su sąlyga, kad yra naudojami pagal mūsų nurodymus: 23 tad, ja lietoti atbilstoši ražotāja norādījumiem, atbilst sekojošiem standartiem un citiem normatīviem dokumentiem: 24 sú v zhode s nasledovnou(ými) normou(ami) alebo iným(i) normatívnym(i) dokumentom(ami), za predpokladu, že sa používajú v súlade s našim návodom: 25 ürünün, talimatlarımıza göre kullanılması koşuluyla aşağıdaki standartlar ve norm belirten belgelerle uyumludur: 01 Directives, as amended. 02 Direktiven, gemäß Änderung. 03 Directives, telles que modifiées. 04 Richtlijnen, zoals geamendeerd. 05 Directivas, según lo enmendado. 06 Direttive, come da modifica. 07 Οδηγιών, όπως έχουν τροποποιηθεί. 08 Directivas, conforme alteração em. 09 Директив со всеми поправками. 16 Megjegyzés * a(z) <A> alapján, a(z) <B> igazolta a megfelelést, a(z) <C> tanúsítvány szerint. 17 Uwaga * zgodnie z dokumentacją <A>, pozytywną opinią <B> i Świadectwem <C>. 18 Notă * aşa cum este stabilit în <A> şi apreciat pozitiv de <B> în conformitate cu Certificatul <C>. 19 Opomba * kot je določeno v <A> in odobreno s strani <B> v skladu s certifikatom <C>. 20 Märkus * nagu on näidatud dokumendis <A> ja heaks kiidetud <B> järgi vastavalt sertifikaadile <C>. Low Voltage 2006/95/EC Machinery 2006/42/EC ** Electromagnetic Compatibility 2004/108/EC * CE - IZJAVA O SKLADNOSTI CE - VASTAVUSDEKLARATSIOON CE - ДЕКЛАРАЦИЯ-ЗА-ϹЪОТВЕТСТВИЕ 17 m deklaruje na własną i wyłączną odpowiedzialność, że modele klimatyzatorów, których dotyczy niniejsza deklaracja: 18 r declară pe proprie răspundere că aparatele de aer condiţionat la care se referă această declaraţie: 19 o z vso odgovornostjo izjavlja, da so modeli klimatskih naprav, na katere se izjava nanaša: 20 x kinnitab oma täielikul vastutusel, et käesoleva deklaratsiooni alla kuuluvad kliimaseadmete mudelid: 21 b декларира на своя отговорност, че моделите климатична инсталация, за които се отнася тази декларация: 22 t visiška savo atsakomybe skelbia, kad oro kondicionavimo prietaisų modeliai, kuriems yra taikoma ši deklaracija: 23 v ar pilnu atbildību apliecina, ka tālāk uzskaitīto modeļu gaisa kondicionētāji, uz kuriem attiecas šī deklarācija: 24 k vyhlasuje na vlastnú zodpovednosť, že tieto klimatizačné modely, na ktoré sa vzťahuje toto vyhlásenie: 25 w tamamen kendi sorumluluǧunda olmak üzere bu bildirinin ilgili olduǧu klima modellerinin aşaǧıdaki gibi olduǧunu beyan eder: CE - IZJAVA-O-USKLAĐENOSTI CE - MEGFELELŐSÉGI-NYILATKOZAT CE - DEKLARACJA-ZGODNOŚCI CE - DECLARAŢIE-DE-CONFORMITATE 08 estão em conformidade com a(s) seguinte(s) norma(s) ou outro(s) documento(s) normativo(s), desde que estes sejam utilizados de acordo com as nossas instruções: 09 соответствуют следующим стандартам или другим нормативным документам, при условии их использования согласно нашим инструкциям: 10 overholder følgende standard(er) eller andet/andre retningsgivende dokument(er), forudsat at disse anvendes i henhold til vore instrukser: 11 respektive utrustning är utförd i överensstämmelse med och följer följande standard(er) eller andra normgivande dokument, under förutsättning att användning sker i överensstämmelse med våra instruktioner: 12 respektive utstyr er i overensstemmelse med følgende standard(er) eller andre normgivende dokument(er), under forutssetning av at disse brukes i henhold til våre instrukser: 13 vastaavat seuraavien standardien ja muiden ohjeellisten dokumenttien vaatimuksia edellyttäen, että niitä käytetään ohjeidemme mukaisesti: 14 za předpokladu, že jsou využívány v souladu s našimi pokyny, odpovídají následujícím normám nebo normativním dokumentům: 15 u skladu sa slijedećim standardom(ima) ili drugim normativnim dokumentom(ima), uz uvjet da se oni koriste u skladu s našim uputama: Η DICz*** είναι εξουσιοδοτημένη να συντάξει τον Τεχνικό φάκελο κατασκευής. A DICz*** está autorizada a compilar a documentação técnica de fabrico. Компания DICz*** уполномочена составить Комплект технической документации. DICz*** er autoriseret til at udarbejde de tekniske konstruktionsdata. DICz*** är bemyndigade att sammanställa den tekniska konstruktionsfilen. DICz*** har tillatelse til å kompilere den Tekniske konstruksjonsfilen. delineato nel <A> e giudicato positivamente da <B> secondo il Certificato <C>. Σημείωση * όπως καθορίζεται στο <A> και κρίνεται θετικά από το <B> σύμφωνα με το Πιστοποιητικό <C>. Nota * tal como estabelecido em <A> e com o parecer positivo de <B> de acordo com o Certificado <C>. Примечание * как указано в <A> и в соответствии с положительным решением <B> согласно Свидетельству <C>. Bemærk * som anført i <A> og positivt vurderet af <B> i henhold til Certifikat <C>. 06 Nota * DICz*** is authorised to compile the Technical Construction File. DICz*** hat die Berechtigung die Technische Konstruktionsakte zusammenzustellen. DICz*** est autorisé à compiler le Dossier de Construction Technique. DICz*** is bevoegd om het Technisch Constructiedossier samen te stellen. DICz*** está autorizado a compilar el Archivo de Construcción Técnica. DICz*** è autorizzata a redigere il File Tecnico di Costruzione. as set out in <A> and judged positively by <B> according to the Certificate <C>. wie in <A> aufgeführt und von <B> positiv beurteilt gemäß Zertifikat <C>. tel que défini dans <A> et évalué positivement par <B> conformément au Certificat <C>. zoals vermeld in <A> en positief beoordeeld door <B> overeenkomstig Certificaat <C>. como se establece en <A> y es valorado positivamente por <B> de acuerdo con el Certificado <C>. 10 under iagttagelse af bestemmelserne i: 11 enligt villkoren i: 12 gitt i henhold til bestemmelsene i: 13 noudattaen määräyksiä: 14 za dodržení ustanovení předpisu: 15 prema odredbama: 16 követi a(z): 17 zgodnie z postanowieniami Dyrektyw: 18 în urma prevederilor: ***DICz = Daikin Industries Czech Republic s.r.o. 01 ** 02 ** 03 ** 04 ** 05 ** 06 ** 05 Nota * 04 Bemerk * 03 Remarque * 02 Hinweis * 01 Note * 01 following the provisions of: 02 gemäß den Vorschriften der: 03 conformément aux stipulations des: 04 overeenkomstig de bepalingen van: 05 siguiendo las disposiciones de: 06 secondo le prescrizioni per: 07 με τήρηση των διατάξεων των: 08 de acordo com o previsto em: 09 в соответствии с положениями: EN60335-2-40, 01 are in conformity with the following standard(s) or other normative document(s), provided that these are used in accordance with our instructions: 02 der/den folgenden Norm(en) oder einem anderen Normdokument oder -dokumenten entspricht/entsprechen, unter der Voraussetzung, daß sie gemäß unseren Anweisungen eingesetzt werden: 03 sont conformes à la/aux norme(s) ou autre(s) document(s) normatif(s), pour autant qu'ils soient utilisés conformément à nos instructions: 04 conform de volgende norm(en) of één of meer andere bindende documenten zijn, op voorwaarde dat ze worden gebruikt overeenkomstig onze instructies: 05 están en conformidad con la(s) siguiente(s) norma(s) u otro(s) documento(s) normativo(s), siempre que sean utilizados de acuerdo con nuestras instrucciones: 06 sono conformi al(i) seguente(i) standard(s) o altro(i) documento(i) a carattere normativo, a patto che vengano usati in conformità alle nostre istruzioni: 07 είναι σύμφωνα με το(α) ακόλουθο(α) πρότυπο(α) ή άλλο έγγραφο(α) κανονισμών, υπό την προϋπόθεση ότι χρησιμοποιούνται σύμφωνα με τις οδηγίες μας: FTX20KV1B, FTX25KV1B, FTX35KV1B, FTX50KV1B, FTX60KV1B, CE - ERKLÆRING OM-SAMSVAR CE - ILMOITUS-YHDENMUKAISUUDESTA CE - PROHLÁŠENÍ-O-SHODĚ 09 u заявляет, исключительно под свою ответственность, что модели кондиционеров воздуха, к которым относится настоящее заявление: 10 q erklærer under eneansvar, at klimaanlægmodellerne, som denne deklaration vedrører: 11 s deklarerar i egenskap av huvudansvarig, att luftkonditioneringsmodellerna som berörs av denna deklaration innebär att: 12 n erklærer et fullstendig ansvar for at de luftkondisjoneringsmodeller som berøres av denne deklarasjon, innebærer at: 13 j ilmoittaa yksinomaan omalla vastuullaan, että tämän ilmoituksen tarkoittamat ilmastointilaitteiden mallit: 14 c prohlašuje ve své plné odpovědnosti, že modely klimatizace, k nimž se toto prohlášení vztahuje: 15 y izjavljuje pod isključivo vlastitom odgovornošću da su modeli klima uređaja na koje se ova izjava odnosi: 16 h teljes felelőssége tudatában kijelenti, hogy a klímaberendezés modellek, melyekre e nyilatkozat vonatkozik: CE - DECLARAÇÃO-DE-CONFORMIDADE CE - ЗАЯВЛЕНИЕ-О-СООТВЕТСТВИИ CE - OVERENSSTEMMELSESERKLÆRING CE - FÖRSÄKRAN-OM-ÖVERENSTÄMMELSE 01 a declares under its sole responsibility that the air conditioning models to which this declaration relates: 02 d erklärt auf seine alleinige Verantwortung daß die Modelle der Klimageräte für die diese Erklärung bestimmt ist: 03 f déclare sous sa seule responsabilité que les appareils d'air conditionné visés par la présente déclaration: 04 l verklaart hierbij op eigen exclusieve verantwoordelijkheid dat de airconditioning units waarop deze verklaring betrekking heeft: 05 e declara baja su única responsabilidad que los modelos de aire acondicionado a los cuales hace referencia la declaración: 06 i dichiara sotto sua responsabilità che i condizionatori modello a cui è riferita questa dichiarazione: 07 g δηλώνει με αποκλειστική της ευθύνη ότι τα μοντέλα των κλιματιστικών συσκευών στα οποία αναφέρεται η παρούσα δήλωση: 08 p declara sob sua exclusiva responsabilidade que os modelos de ar condicionado a que esta declaração se refere: Daikin Industries Czech Republic s.r.o. CE - DECLARATION-OF-CONFORMITY CE - KONFORMITÄTSERKLÄRUNG CE - DECLARATION-DE-CONFORMITE CE - CONFORMITEITSVERKLARING 3P394245-1B English Safety Precautions • The precautions described herein are classified as WARNING and CAUTION. They both contain important information regarding safety. Be sure to observe all precautions without fail. • Meaning of WARNING and CAUTION notices WARNING.....Failure to follow these instructions properly may result in personal injury or loss of life. CAUTION......Failure to observe these instructions properly may result in property damage or personal injury, which may be serious depending on the circumstances. • The safety marks shown in this manual have the following meanings: Be sure to follow the instructions. Be sure to establish an earth connection. Never attempt. • After completing installation, conduct a trial operation to check for faults and explain to the customer how to operate the air conditioner and take care of it with the aid of the operation manual. • The English text is the original instruction. Other languages are translations of the original instructions. WARNING • Ask your dealer or qualified personnel to carry out installation work. Do not attempt to install the air conditioner yourself. Improper installation may result in water leakage, electric shocks or fire. • Install the air conditioner in accordance with the instructions in this installation manual. Improper installation may result in water leakage, electric shocks or fire. • Be sure to use only the specified accessories and parts for installation work. Failure to use the specified parts may result in the unit falling, water leakage, electric shocks or fire. • Install the air conditioner on a foundation strong enough to withstand the weight of the unit. A foundation of insufficient strength may result in the equipment falling and causing injury. • Electrical work must be performed in accordance with relevant local and national regulations and with instructions in this installation manual. Be sure to use a dedicated power supply circuit only. Insufficiency of power circuit capacity and improper workmanship may result in electric shocks or fire. • Use a cable of suitable length. Do not use tapped wires or an extension lead, as this may cause overheating, electric shocks or fire. • Make sure that all wiring is secured, the specified wires are used, and that there is no strain on the terminal connections or wires. Improper connections or securing of wires may result in abnormal heat build-up or fire. • When wiring the power supply and connecting the wiring between the indoor and outdoor units, position the wires so that the control box lid can be securely fastened. Improper positioning of the control box lid may result in electric shocks, fire or over heating terminals. • If refrigerant gas leaks during installation, ventilate the area immediately. Toxic gas may be produced if the refrigerant comes into contact with fire. • After completing installation, check for refrigerant gas leakage. Toxic gas may be produced if the refrigerant gas leaks into the room and comes into contact with a source of fire, such as a fan heater, stove or cooker. • When installing or relocating the air conditioner, be sure to bleed the refrigerant circuit to ensure it is free of air, and use only the specified refrigerant (R410A). The presence of air or other foreign matter in the refrigerant circuit causes abnormal pressure rise, which may result in equipment damage and even injury. • During installation, attach the refrigerant piping securely before running the compressor. If the refrigerant pipes are not attached and the stop valve is open when the compressor is run, air will be sucked in, causing abnormal pressure in the refrigeration cycle, which may result in equipment damage and even injury. • During pump-down, stop the compressor before removing the refrigerant piping. If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed, causing abnormal pressure in the refrigeration cycle, which may result in equipment damage and even injury. • Be sure to earth the air conditioner. Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead. Imperfect earthing may result in electric shocks. • Be sure to install an earth leakage breaker. Failure to install an earth leakage breaker may result in electric shocks or fire. CAUTION • Do not install the air conditioner at any place where there is a danger of flammable gas leakage. In the event of a gas leakage, build-up of gas near the air conditioner may cause a fire to break out. • While following the instructions in this installation manual, install drain piping to ensure proper drainage and insulate piping to prevent condensation. Improper drain piping may result in indoor water leakage and property damage. • Tighten the flare nut according to the specified method such as with a torque wrench. If the flare nut is too tight, it may crack after prolonged use, causing refrigerant leakage. English 1 • This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial and household use by lay persons. • Sound pressure level is less than 70 dB(A). Accessories Indoor unit A – H A Mounting plate 1 D Remote controller holder 1 G Operation manual 1 B Titanium apatite photocatalytic air-purifying filter 2 E Dry battery AAA. LR03 (alkaline) 2 H Installation manual 1 C Wireless remote controller 1 F Indoor unit fixing screw (M4 × 12L) 2 Choosing an Installation Site Before choosing the installation site, obtain user approval. 1. Indoor unit • The indoor unit should be sited in a place where: 1) the restrictions on installation specified in the indoor unit installation drawings are met, 2) both air inlet and air outlet have clear paths met, 3) the unit is not in the path of direct sunlight, 4) the unit is away from the source of heat or steam, 5) there is no source of machine oil vapour (this may shorten indoor unit life), 6) cool (warm) air is circulated throughout the room, 7) the unit is away from electronic ignition type fluorescent lamps (inverter or rapid start type) as they may shorten the remote controller range, 8) the unit is at least 1m away from any television or radio set (unit may cause interference with the picture or sound), 9) no laundry equipment is located. 2. Wireless remote controller • Turn on all the fluorescent lamps in the room, if any, and find the site where remote controller signals are properly received by the indoor unit (within 7m). 2 English 1. Removing and installing the front panel English Preparation before Installation Indentations on the main unit • Removal method 1) Place your fingers in the indentations on the main unit (one each on the left and right sides), and open the front panel until it stops. 2) Continue to open the front panel further while sliding the panel to the right and pulling it toward you in order to disengage the front panel shaft on the left side. To disengage the front panel shaft on the right side, slide the panel to the left while pulling it toward you. Front panel shaft • Installation method Align the tabs of the front panel with the grooves, and push all the way in. Then close slowly. Push the centre of the lower surface panel firmly to engage the tabs. 2. Upper hook mark area (3 locations) Removing and installing the front grille • Removal method 1) Remove the front panel to remove the air filter. 2) Remove the 3 screws from the front grille. 3) In front of the mark of the front grille, there are 3 upper hooks. Lightly pull the front grille toward you with one hand, and push down on the hooks with the fingers of your other hand. Push down. Upper hook When there is no work space because the unit is close to ceiling CAUTION • Be sure to wear protection gloves. Place both hands under the centre of the front grille, and while pushing up, pull it toward you. 1) Push up. • Installation method 1) Install the front grille and firmly engage the upper hooks (3 locations). 2) Install 3 screws of the front grille. 3) Install the air filter and then mount the front panel. 3. How to set the different addresses 2) Pull toward you. When 2 indoor units are installed in one room, the 2 wireless remote controllers can be set for different addresses. Change the address setting of one of the two units. When cutting the jumper be careful not to damage any of the surrounding parts. 1) Remove the battery cover on the remote controller and cut the address jumper. 2) Press , and at the same time. Jumper 3) Press , select , press . Jumper EXIST CUT ADDRESS 1 2 (The indoor unit OPERATION lamp will blink for about 1 minute.) 4) Press the indoor unit ON/OFF switch while the OPERATION lamp is blinking. • If setting could not be carried out completely while the OPERATION lamp was blinking, carry out the setting process once again from the beginning. • After setting is complete, pressing for about 5 seconds will cause the remote controller to return to the previous display. English OPERATION lamp ON/OFF Indoor unit ON/OFF switch 3 Indoor Unit Installation Drawings How to attach the indoor unit Hook the hooks of the bottom frame to the A mounting plate. If the hooks are difficult to hook, remove the front grille. A Mounting plate How to remove the indoor unit Push up the marked area (at the lower part of the front grille) to release the hooks. If it is difficult to Front grille release, remove the front grille. Hook Bottom frame Mark (rear side) The A mounting plate should be installed on a wall which can support the weight of the indoor unit. B Mounting plate fixing screw (field supply: M4 x 25L) Caulk pipe hole gap with putty. 30mm or more from ceiling Front panel 50mm or more from walls (on both sides) Air filters A Mounting plate Appearance of indoor units may differ from some models. (This is a 20, 25 and 35 class illustration) Screws M4 × 16L Cut thermal insulation pipe to an appropriate length and wrap it with tape, making sure that no gap is left in the insulation pipe’s cut line. Wrap the insulation pipe with the finishing tape from bottom to top. Service lid The service lid is removable. Opening method 1) Remove the service lid screw. 2) Pull out the service lid horizontally in the direction of the arrow. 3) Pull down. C Titanium apatite photocatalytic air-purifying filter (2) 20, 25 and 35 class Titanium apatite photocatalytic air-purifying filter Before screwing the E remote controller holder to the wall, make sure that control signals are properly received by indoor unit. 50 and 60 class Filter frame Claw Titanium apatite photocatalytic air-purifying filter D Wireless remote controller Tab Air filter 4 F Fixing screw for remote controller holder (field supply: M3 x 20L) E Remote controller holder English 1. English Indoor Unit Installation Installing the mounting plate • The mounting plate should be installed on a wall which can support the weight of the indoor unit. 1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the boring points on the wall. 2) Secure the mounting plate to the wall with screws. Recommended mounting plate retention spots and dimensions 20, 25, and 35 class Recommended mounting plate retention spots (7 spots in all) Place a leveler on these tabs. Through-the-wall hole I65 Drain hose position 117 116.5 237 44.5 44.5 285 213 170 48 337 The removed pipe port cover can be kept in the mounting plate pocket. 48 337 Liquid pipe end 770 Place the pipe port cover in this pocket. 170 Gas pipe end 50 Removed pipe port cover Use a tape measure as shown. Position the end of the tape measure at A Mounting plate . Place a leveler on these tabs. Recommended mounting plate retention spots (7 spots in all) 117 126.5 Through-the-wall hole I80 44.5 44.5 295 333 48 60 171.5 Gas pipe end 447 990 435 Liquid pipe end 171.5 Drain hose position 60 unit: mm English 5 Indoor Unit Installation 2. Boring a wall hole and installing wall embedded pipe • For walls containing metal frame or metal board, be sure to use a wall Inside Wall embedded pipe embedded pipe and wall cover in the feed-through hole to prevent possible (field supply) heat, electrical shock, or fire. • Be sure to caulk the gaps around the pipes with caulking material to prevent water leakage. 1) Bore a feed-through hole of 65mm in the wall so it has a down slope Wall hole cover toward the outside. (field supply) 2) Insert a wall pipe into the hole. 3) Insert a wall cover into wall pipe. 4) After completing refrigerant piping, wiring, and drain piping, caulk pipe hole gap with putty. 3. Outside Caulking 65 Wall embedded pipe (field supply) Installing the indoor unit • In the case of bending or curing refrigerant pipes, keep the following precautions in mind. Abnormal sound may be generated if improper work is conducted. 1) Do not strongly press the refrigerant pipes onto the bottom frame. 2) Do not strongly press the refrigerant pipes on the front grille, either. • Remove the pipe port cover as shown below. 1) Cut off the pipe port cover from inside the front grille using a copping saw. Apply the blade of the copping saw to the notch, and cut off the pipe port cover along the uneven inner surface. 2) After cutting off the pipe port cover, perform filing. Remove the burrs along the cut section using a half round needle file. CAUTION • If the pipe port cover is cut off using nippers, the front grille will be damaged. Please do not use nippers. • Wear gloves during the pipe port cover removal. 3-1. Right-side, right-back, or right-bottom piping 1) Attach the drain hose to the underside of the refrigerant pipes with adhesive vinyl tape. 2) Wrap the refrigerant pipes and drain hose together with insulation tape. Right-side piping Remove pipe port cover here for right-side piping. Right-back piping Right-bottom piping Remove pipe port cover here for right-bottom piping. 6 Bind refrigerant pipe and drain hose together with insulating tape. English 3) Pass the drain hose and refrigerant pipes through the wall hole, then set the indoor unit on the mounting plate hooks by using the markings at the top of the indoor unit as a guide. 4) Open the front panel, then open the service lid. (Refer to preparation before installation.) 5) Pass the inter-unit wire from the outdoor unit through the feed-through wall hole and then through the back of the indoor unit. Pull them through the front side. Bend the ends of tie wires upward for easier work in advance. (If the inter-unit wire ends are to be stripped first, bundle wire ends with adhesive tape.) 6) Press the bottom frame of the indoor unit with both hands to set it on the mounting plate hooks. Make sure the wires do not catch on the edge of the indoor unit. English English Indoor Unit Installation Mounting plate Hang indoor unit’s hook here. Mounting plate When stripping off the ends of inter-unit wire in advance, cover the ends with insulating tape to make it easier to pass the wire. Wire guide Inter-unit wire 7 Indoor Unit Installation 3-2. Left-side, left-back, or left-bottom piping How to replace the drain plug and drain hose • Replacing onto the left side Drain hose attachment position 1) Remove the insulation fixing screw on the right and remove the drain hose. 2) Remove the drain plug on the left side and attach it to the right side. 3) Insert the drain hose and tighten with included insulation fixing screw. * (Forgetting to tighten this may cause water leakages.) * The drain hose is on the back of the unit. Left side Right side Front side of unit Attachment on the left side Attachment on the right side (factory default) Insulation fixing screw Insulation fixing screw Drain hose Drain hose 1) Attach the drain hose to the underside of the refrigerant pipes with adhesive vinyl tape. Remove pipe port cover here for leftside piping. Left-side piping Left-back piping Remove pipe port cover here for left-bottom piping. Left-bottom piping 2) Be sure to connect the drain hose to the drain port in place of a drain plug. How to set drain plug No g 3) Shape the refrigerant pipes along the pipe path marking on the mounting plate. 4) Pass the drain hose and refrigerant pipes through the wall hole, then set the indoor unit on mounting plate hooks, using the markings at the top of the indoor unit as a guide. 5) Pull in the inter-unit wire. 6) Connect the inter-unit pipes. ap. Drain hose Caulk this hole with putty or caulking material. Do not apply lubricating oil (refrigerant oil) to the drain plug when inserting it. The application of lubrication oil to the drain plug will deteriorate the plug and cause drain leakage from the plug. Insert a hexagonal wrench (4mm). Mounting plate Bind with adhesive vinyl tape. 7) Wrap the refrigerant pipes and drain hose together with insulation tape as shown in the figure on the right (in case of setting the drain hose through the back of the indoor unit). 8) While exercising care so that the inter-unit wire does not catch indoor unit, press the bottom edge of indoor unit with both hands until it is firmly caught by the mounting plate hooks. Secure indoor unit to the mounting plate with indoor unit fixing screws (M4 × 12L). Wrap insulating tape around the bent portion of refrigerant pipes. Overlap at least half the width of the tape with each turn. Inter-unit wire Drain hose Mounting plate Refrigerant pipes Bottom frame Indoor unit fixing screw (M4 × 12L) (2 locations) 3-3. Wall embedded piping Follow the instructions given under left-side, left-back, or left-bottom piping. 1) Insert the drain hose to this depth so it won’t be pulled out of the drain pipe. Insert drain hose to this depth so it won’t be pulled out of drain pipe. 50mm or more Outer wall 8 Inner wall Drain hose Vinyl chloride drain pipe (VP-30) English English Indoor Unit Installation Wiring diagram : Terminal strip : Connection : Connector : Field wiring BLK : Black ORG : Orange BLU : Blue RED : Red BRN : Brown WHT : White GRN : Green YLW : Yellow Notes : Refer to the nameplate for power requirements. : INDOOR : OUTDOOR Outdoor : RECTIFIER Rectifier : TRANSMISSION CIRCUIT Transmission circuit : WIRELESS REMOTE CONTROLLER Wireless remote controller : SIGNAL RECEIVER Signal receiver Indoor Wiring diagram parts table FG.......................... Frame ground FU1 ........................ Fuse (3,15A) H1~H3 ................... Harness H1P, H2P ............... Pilot lamp MR10 ..................... Magnetic relay M1F........................ Fan motor M1S ....................... Swing motor PCB1~PCB3 .......... Printed circuit board R1T,R2T................. Thermistor S6~S602 ................ Connector S1W ....................... Operation switch V2 .......................... Varistor X1M ....................... Terminal strip Z1C ........................ Ferrite core ....................... Protective earth CAUTION Note that operation will restart automatically if the main power supply is turned off and then back on again. HIGH VOLTAGE – be sure to discharge the capacitor completely before repair work. Risk of failure or water leakage! Do not wash the inside of the air conditioner by yourself. English 9 Indoor Unit Installation 4. Wiring 1) Strip wire ends (15mm). 2) Match wire colours with terminal numbers on indoor and outdoor unit’s terminal blocks and firmly screw wires to the corresponding terminals. 3) Connect the earth wires to the corresponding terminals. 4) Pull wires to make sure that they are securely latched up, then retain wires with wire retainer. 5) Shape the wires so that the service lid fits securely, then close service lid. Terminal block Electrical component box Shape wires so that the service lid will fit securely. Firmly secure wire retainer so that wires sustain no external stress. Use the specified wire type. Wire retainer Firmly fix the wires with the terminal screws. Outdoor unit Inter-unit wire 4-core 1.5mm² or more H05RN Indoor unit Firmly fix the wires with the terminal screws. WARNING • Do not use tapped wires, stranded wires, extension cords, or starburst connections, as they may cause overheating, electrical shock, or fire. • Do not use locally purchased electrical parts inside the product. (Do not branch the power for the drain pump, etc., from the terminal block.) Doing so may cause electric shock or fire. • Do not connect the power wire to the indoor unit. Doing so may cause electric shock or fire. 10 English 5. Drain piping The drain hose should be inclined downward. 1) Connect the drain hose, as described right. No trap is permitted. Do not put the end of the hose in water. 2) Remove the air filters and pour some water into the drain pan to check the water flows smoothly. 3) If drain hose extension or embedded drain piping is required, use appropriate parts that match the hose front end. [Figure of hose front end] 4) When extending the drain hose, use a commercially available extension hose with an inner diameter of 16mm. Be sure to thermally insulate the indoor section of the extension hose. 5) When connecting a rigid polyvinyl chloride pipe (nominal diameter 13mm) directly to the drain hose attached to the indoor unit as with embedded piping work, use any commercially available drain socket (nominal diameter 13mm) as a joint. Extension drain hose Indoor unit drain hose Drain hose supplied with the indoor unit Drain hose supplied with the indoor unit Heat insulation tube (field supply) Commercially available drain socket (nominal diameter 13mm) Commercially available rigid polyvinyl chloride pipe (nominal diameter 13mm) Refrigerant Piping Work 1. Flaring the pipe end 1) Cut the pipe end with a pipe cutter. 2) Remove burrs with the cut surface facing downward so that the chips do not enter the pipe. 3) Put the flare nut on the pipe. 4) Flare the pipe. 5) Check that the flaring is properly made. (Cut exactly at right angles.) Remove burrs. Flaring Set exactly at the position shown below. A Die A Flare tool for R410A Conventional flare tool Clutch-type Clutch-type (Rigid-type) Wing-nut type (Imperial-type) 0-0.5mm 1.0-1.5mm Check Flare’s inner surface must be flaw-free. 1.5-2.0mm The pipe end must be evenly flared in a perfect circle. Make sure that the flare nut is fitted. WARNING • • • • • • Do not use mineral oil on flared part. Prevent mineral oil from getting into the system as this would reduce the lifetime of the units. Never use piping which has been used for previous installations. Only use parts which are delivered with the unit. Never install a dryer to this R410A unit in order to guarantee its lifetime. The drying material may dissolve and damage the system. Incomplete flaring may cause refrigerant gas leakage. English 11 English Indoor Unit Installation Refrigerant Piping Work 2. Refrigerant piping CAUTION • Use the flare nut fixed to the main unit. (To prevent cracking of the flare nut by aged deterioration.) • To prevent gas leakage, apply refrigeration oil only to the inner surface of the flare. (Use refrigeration oil for R410A.) • Use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and gas leakage. Align the centres of both flares and tighten the flare nuts 3 or 4 turns by hand. Then tighten them fully with the torque wrenches. [Apply oil] [Tighten] Torque wrench Apply refrigeration oil to the inner surface of the flare. Do not apply refrigeration oil to the outer surface. Flare nut Spanner Piping union Flare nut Do not apply refrigeration oil to the flare nut to avoid tightening with excessive torque. Flare nut tightening torque Gas side 20, 25, 35 class 50, 60 class 1/2 inch 3/8 inch 32.7-39.9N • m (330-407kgf • cm) 59.5-60.3N • m (505-615kgf • cm) Liquid side 1/4 inch 14.2-17.2N • m (144-175kgf • cm) 2-1. Caution on piping handling Wall Be sure to place a cap. 1) Protect the open end of the pipe against dust and moisture. 2) All pipe bends should be as gentle as possible. Use a pipe bender for bending. Rain If no flare cap is available, cover the flare mouth with tape to keep dirt or water out. 2-2. Selection of copper and heat insulation materials Inter-unit wire • When using commercial copper pipes and fittings, observe the following: 1) Insulation material: Polyethylene foam Heat transfer rate: 0.041 to 0.052W/mK (0.035 to 0.045kcal/mh°C) Refrigerant gas pipe’s surface temperature reaches 110°C max. Choose heat insulation materials that will withstand this temperature. Gas pipe Liquid pipe Gas pipe insulation Finishing tape 2) Be sure to insulate both the gas and liquid piping and to provide insulation dimensions as below. Gas side 20,25,35 class 50,60 class O.D. 9.5mm O.D. 12.7mm Liquid pipe insulation Drain hose Liquid side Gas pipe thermal insulation Liquid pipe thermal insulation O.D. 6.4mm I.D. 12-15mm I.D. 8-10mm Minimum bend radius Thickness 10mm min. 30mm or more Thickness 0.8mm (C1220T-O) 3) Use separate thermal insulation for gas and liquid refrigerant pipes. 12 English 1. English Trial Operation and Testing Trial operation and testing • Trial operation should be carried out in either COOL or HEAT operation. 1-1. Measure the supply voltage and make sure that it is within the specified range. 1-2. In COOL operation, select the lowest programmable temperature; in HEAT operation, select the highest programmable temperature. 1-3. Carry out the trial operation in accordance with the operation manual to ensure that all functions and parts, such as flap movement, are working properly. • For protection, the system disables restart operation for 3 minutes after it is turned off. 1-4. After trial operation is complete, set the temperature to a normal level (26°C to 28°C in COOL operation, 20°C to 24°C in HEAT operation). • When operating the air conditioner in COOL operation in winter, set it to the trial operation mode using the following method. 1) Press , 2) Press , select 3) Press and or at the same time. , press . to turn on the system. • Trial operation will stop automatically after about 30 minutes. To stop the operation, press . • Some of the functions cannot be used in the trial operation mode. • The air conditioner draws a small amount of power in its standby mode. If the system is not to be used for some time after installation, shut off the circuit breaker to eliminate unnecessary power consumption. • If the circuit breaker trips to shut off the power to the air conditioner, the system will restore the original operation mode when the circuit breaker is opened again. 2. Test items Test items Symptom Indoor and outdoor units are installed properly on solid bases. Fall, vibration, noise No refrigerant gas leaks. Incomplete cooling/heating function Refrigerant gas and liquid pipes and indoor drain hose extension are thermally insulated. Water leakage Draining line is properly installed. Water leakage System is properly earthed. Electrical leakage The specified wires are used for inter-unit wiring. Inoperative or burn damage Indoor or outdoor unit’s air inlet or air outlet are unobstructed Incomplete cooling/heating function Stop valves are opened. Incomplete cooling/heating function Indoor unit properly receives remote control commands. No operation English Check 13 3P393185-1A 2014.10 Copyright 2014 Daikin
advertisement
Key Features
- R410A refrigerant
- Inverter technology
- Split system
- Indoor and Outdoor Units
- Wireless remote control
- Titanium apatite photocatalytic air-purifying filter
- Automatic restart
- Trial operation mode
- Easy to install
- Detailed instructions