Jablotron JK-16 PROFI JK-16 alarm system, JA-60N door sensor, JA-60P motion detector, JA-63F keypad, RC-44 remote control, UC-260 indoor siren, JA-63A wireless outdoor siren Installation instructions

Jablotron JK-16 PROFI JK-16 alarm system, JA-60N door sensor, JA-60P motion detector, JA-63F keypad, RC-44 remote control, UC-260 indoor siren, JA-63A wireless outdoor siren Installation instructions

Below you will find brief information for alarm system JK-16 PROFI JK-16, door sensor JA-60N, motion detector JA-60P, keypad JA-63F, remote control RC-44. The JK-16 PROFI JK-16 is a home alarm system that includes wireless door sensor JA-60N, motion detector JA-60P, remote control keypad JA-63F, and indoor siren UC-260. The JK-16 PROFI JK-16 system can be expanded with additional accessories: wireless outdoor siren JA-63A.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

JK-16 PROFI JK-16 Installation Instructions | Manualzz

JK-16 PROFI

• Installation instructions - only Jablotron distributor certified installers should install this kit.

• Detailed manuals for all included components can be found on the enclosed CD or on the Jablotron website www.jablotron.com

1. Kit contents

All items in the kit are enrolled and preprogrammed. The detectors and remote controls have batteries pre-installed.

Item description

JA-60N wireless door sensor

JA-60P wireless motion detector

JA-63F wireless keypad

RC-44 remote control

UC-260 wireless indoor siren address

1

2 c1 c2 panel is enrolled

The RC-42 is the same remote control as the RC-44 except that it is built into a housing with only two buttons ( & ), which have identical functions to the left pair of RC-44 buttons.

2. Before installation

3. Control panel installation

a) Install the control panel - see the drilling template on the last page of this manual. b) Install and connect the backup battery to the control panel c) Connect the AC power to the control panel d) The Green LED should flash in the control panel e) Connect the keypad’s batteries (pull out the red tape to activate batteries). P will be indicated on the keypad

(programming mode).

• If F is indicated, there is no communication with the control panel.

• Enter F0 6060 to re-enter P mode if you accidentally exit it by pushing the N key

To save the keypad batteries, close its cover.

Decide upon suitable locations for all of the devices. The wireless keypad should be within 20m of the control panel.

There should be power and a telephone line available for the control panel.

RESET

Green LED

JK-16 PROFI 1/4 MGK24401

4. Detector and accessory installation

a) Install the JA-60N magnetic detector onto the door

(antenna pointing up or down) b) Install the JA-60P PIR motion detector

A

Don't tight this screw

B rear tamper lever attach click

C open height

[m] 2,5

2 avoid locations against windows or close to a heater

JA-60P coverage

12 m zone C zone B zone A

1,5

1 zone A

0,5 zone C zone B

1,6 3,7

120 ş

12 range [m] c) Select Instant or Delay reactions via the DIP switches inside the detectors. d) Connect the detector’s batteries (pull out the red tape to activate the batteries) e) Attach the keypad to the desired location f) Plug the UC-260 wireless siren into a power socket g) Test the wireless doorbell button and install it.

5. Enrollment of additional accessories

If you install additional detectors (max. 32), you have to enroll them. The system should be in P mode (if not enter F0 6060): a) Press 1 to enter enrollment mode* b) The next free detector position will be displayed on the

keypad. c) Install batteries into all new detectors step by step to enroll them (system will automatically offer the next free position) d) To scroll through sensor positions, press 1 (up) or 7 (down) e) To enroll a second detector to an occupied position press 5 before you install the detector’s batteries f) To exit enrollment mode press the N key

The wireless keypad (JA-63F) enrolls after you install its battery while in enrollment mode.

The remote control (RC-4x) enrolls after you press and hold both and buttons while in enrollment mode.

The wireless outdoor siren (JA-63A) enrolls after it is powered up while in enrollment mode

To enroll the control panel to UC receivers enter 299 on the keypad while in P mode

Check individual device manuals for more details

• *Enrollment mode will also start after shorting the reset pins in the control panel while it is in P mode.

6. Detector and controller testing

a) The system should be in P mode (if not enter F0 6060) b) Trigger detectors – their addresses (1=door and 2=PIR) should be indicated (if the PIR detector does not react, re-enter test mode by opening and closing its cover) c) Press button on the RC-4x remote control c2 will be indicated

7. To measure the strength of the radio signal

a) While in P mode, press 1 and then using 7 scroll to position 1 b) Press 8 to start measuring c) Activate the door detector to view its signal strength d) Using the 1 key, scroll to the next position (2 PIR) and check its signal strength (if the PIR detector does not react, reenter its test mode by opening and closing its cover) e) Repeat step d) to check all enrolled items. The wireless keypad

(c1) signal is indicated after you trigger its tamper. The remote

control (c2) is indicated after you press it’s button. f) Change the location of an item if its signal is lower than 2 g) Return to P mode by pressing the N key

8. Programming the system

a) The system should be in P mode (if not enter F0 6060) b) Using the following sequences you can program:

Function Sequence Comments

Your installer code* 5 xxxx xxxx 6060 factory default xxxx new code

20x 3=30sec factory def. Exit delay

Entrance delay

Alarm duration

Time & date

21x 3=30 sec factory def.

22x 4=4min factory def.

4 hh mm DD MM YY

See control panel installation manual for more details.

• Must be changed

9. Finishing the installation

a) Fill in the information on the sticker label and attach it inside the keypad cover. b) Switch the system to standby (by pressing the N key) c) Instruct the user on how to operate the system

JK-16 PROFI 2/4 MGK24401

10. Keypad operation

F1 /

F2 /

F3 /

F4

F5

F6

Entry Function

User code Arming / Disarming (Setting\Unsetting)

Arming without a code

Partial arming

Door lock opening

Memory reading

New master code (example: F5 1234 2789 2789)

User codes setting (example: F6 1234 03 3344)

F7 /

F8

Disarming under duress

Appliance control (F81 = ON, F80 = OFF)

F0 M.code User test mode (example F0 1234)

N Escape & fault detail reading

11. Specifications

Power

Power supply

230 VAC, max 0.1 A, supervised, class II

A type (EN 50131-6)

Backup battery 12 V, 2.26 Ah, normal life time 5 years

Backup power output 13VDC, the max. permanent current is 0.4 or 1A for max. 15 min (1 cycle per hour),

Consumption of the control panel is 30 mA; JA-60E 25 mA

Hard-wired inputs

Wireless zones

4 input zones, selectable triggering:

16 zones (2 detectors can be enrolled to each

Wireless controllers

Access codes max. 8 (JA-60F, RC-22, RC-44) master code and 14 user codes.

Wired outputs Alarm relay dry contacts 1A/60V;

Programmable outputs PgX , PgY connect to the GND max. 0,1 A

Siren output 12 V, 0.7 A

Working frequency* 433.92 MHz; digital hopping code; supervised communication

Comply with EN 50131-1, EN 50131-6

Security grade

Environmental class

Safety

2 (low to medium risk)

II indoor – general (-10 to 40oC)

EN 60950-1

EMC

Radio characteristics

ETS 300683

ETSI EN 300220

Can be operated according to ERC REC 70-03

Jablotron Alarms a.s. hereby declares that the JA-83K “OASiS“ control panel is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. The original of the conformity assessment can be found on the web site www.jablotron.com, Technical Support section.

Note: Dispose of batteries safely depending on the type of the batteries and local regulation. Although this product does not contain any harmful materials we suggest you to return the

product to the dealer or directly to the producer after usage.

Motion detector

JA-60P

Control panel

JA-63KR

Indoor siren

UC-260

(230 V AC)

Power (230 V AC)

Doors, Windows

JA-60N

Remote control

RC-4x

Wireless keypad

JA-63F

JK-16 PROFI 3/4 MGK24401

Motion detector

JA-60P

JK-16 PROFI

Control panel drilling template

4/4 MGK24401

advertisement

Key Features

  • Wireless door and motion detection
  • Remote control arming/disarming
  • Expandable with additional accessories
  • Easy to install and program
  • User-friendly keypad interface
  • Backup battery for reliable operation
  • Siren output for audible alarm
  • Supervision of communication with detectors
  • Multiple user codes for access control
  • Programmable output for integration

Frequently Answers and Questions

How can I re-enter P mode?
If you accidentally exit P mode by pushing the N key, you can re-enter it by pushing F0 6060.
How do I enroll additional accessories?
The system should be in P mode. Press 1 to enter enrollment mode. Install batteries into all new detectors step by step to enroll them.
How do I test the system?
The system should be in P mode. Trigger detectors and check their addresses. Press the button on the RC-4x remote control to check the remote control.