- Home
- Home security & automation
- Security device components
- Rosslare
- EX 07
- Installation manual
- 4 Pages
Rosslare EX 07, EX 17 REX button Installation Manual
Below you will find brief information for REX button EX 07, REX button EX 17. The EX-07 and EX-17 are heavy-duty, non-sparking, non-magnetic, corrosion resistant, illuminated, anti-vandal, timed digital REX (Request-for-Exit) buttons, designed for both indoor and outdoor use. They feature solid state Piezoelectric Switch Technology generating 2 isolated Form C output pulses with a simple touch of a finger, with no physical movement or moving parts. They also have a built-in buzzer, and are crafted to the highest manufacturing standards out of the finest materials under Rosslare’s ISO 9001:2000 Certified Quality standards.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
EX-07/EX-17
Non-Sparking Digital Tactile REX Button
Installation Manual
1.
Introduction
Rosslare’s EX-07/EX-17 electronic REX buttons control the access of a magnetic lock or electric lock strike. The EX-07 and EX-17 are heavyduty, non-sparking, non-magnetic, corrosion resistant, illuminated, antivandal, timed digital REX (Request-for-Exit) buttons, designed for both indoor and outdoor use.
They feature solid state Piezoelectric Switch Technology generating 2 isolated Form C output pulses with a simple touch of a finger, with no physical movement or moving parts.
Among the many features of the EX-07 and EX-17 are: Jumper selectable illumination status with light dimming option, buzzer mode, 2 Form C relays, timed operation, and relay toggle option.
The EX-07 and EX-17 mount directly to standard US-size gang switchboxes and are crafted to the highest manufacturing standards out of the finest materials under Rosslare’s ISO 9001:2000 Certified Quality standards.
2.
Technical Specifications
2.1
Operational Characteristics
Jumpers
Timer
Lighting Behavior
2.2
The EX-07/17 is equipped with 8 jumpers (see
The timed option (External 1) is set by a built-in potentiometer for 1 to 60 seconds
When a colored light toggles on or off, it dims from the On to Off state and lights up from the Off to On state at a duration of about 500 ms. The dimming or lighting duration starts on the on or off command.
In the case of toggling between two colors, the effect results in gradual color change between red and green.
Electrical Characteristics
Operating Voltage Range 12 to 24 VAC/VDC
Maximum Current
Consumption
Relay Outputs
Maximum: Less than 150 mA at 12 VAC
1 x 2 A relay with two isolated Form C:
Common, Normally Open (N.O.), Normally Closed
(N.C.)
Dual outputs are able to switch up to 2 A at 24
VAC/DC
Button Life
Relay Life Expectancy
Inputs
1 billion cycles
100,000 @ 2A 30 VDC, 500,000 @ 1A 30 VDC
Blink Mode input
General Features
Figure 1: EX-07 Figure 2: EX-17
2.3
Environmental Characteristics
Operating Environment Indoors and outdoors (meets IP65)
Operating Temperature
Range
-35˚C to 66˚C (-31˚F to 151˚F)
0 to 85% (Non-condensing) Operating Humidity
Range
RFI Protection >20 V/m up to 1000 MHz (not investigated by UL)
2.4
Material
Physical Characteristics
Dimensions
Weight
Smoothly brushed stainless steel plate with a rounded-corner, 25 mm wide rectangular pressing area in the center for operating a piezoelectric sensor.
EX-07: 11.4 x 7 x 3.2 cm (4.5 x 2.76 x 1.26 in.)
EX-17: 11.4 x 4.4 x 3.2 cm (4.5 x 1.73 x 1.26 in.)
EX-07: 277 g (9.8 oz.)
EX-17: 205 g (7.2 oz.)
The main features of the EX-07/EX-17 are:
REX Button Technology: Advanced Soft Touch Piezoelectric REX
Button
New Weatherproof Design: Circuit assembly encapsulation
Vandal Resistant: Stainless steel mounting plate and solid state REX button (Vandal was not verified by UL)
Adjustable Output Time: The timer can be set from 1 to 60 seconds for the relay as well as for LED activation
Field Selectable Illumination Status: Jumper selected
Mounting Method: Mounts directly to a single gang switchbox
Faceplate Graphics: “EXIT”, “PUSH TO EXIT”, or no graphic, custom laser marked black graphics available
1
3.
Installation
3.1
Selecting an Area for Installation
You need to select the best physical location to install the EX-07/EX17.
The EX-07/EX-17 REX button has a face plate attached to an inlay that is imbedded in a wall with all of its wiring. The EX-07/17 should be connected to additional equipment in the same room.
To select a physical location:
1.
Select a flat wall in close proximity to the door or item the REX button will control.
2.
Ensure that there are no iron beams, door frames, or other obstructions that would prevent the insertion of the inlay in the wall.
3.
Stick the mounting plate provided on the wall to ensure quick and easy installation of the product.
4.
Mark the dimensions of the inlay on the wall:
70 x 38 x 27 mm (2.75 x 1.47 x 1.06 in.)
Figure 3 provides a view of the back of the inlay.
Figure 3: Inlay Back View
3.2
Mounting the REX Button
To mount the REX button:
1.
Make a hole in the wall measuring the required dimensions, adding
0.5 cm (1/8”) on all sides for the gang box to slide in smoothly.
2.
Unscrew the cover on the small box containing the jumpers and potentiometer.
3.
Using a small screwdriver, set the time on the potentiometer.
Turning the timer clockwise all the way sets the timer for one second. Turning the timer counter-clockwise all the way sets the timer for 60 seconds.
4.
Connect the wires as described in Section 3.3.
5.
Set the jumper connections located on the bottom right side of the
6.
Screw the sealed cover back on the small box containing the jumpers and potentiometer.
7.
Test the REX button before screwing the inlay to the gang box (see
8.
Place the inlay with face plate in the gang box, making sure screw alignment is correct and the face plate lies flush against the wall.
9.
Insert screws in the face plate and screw tightly to ensure a water tight seal that protects the inner wiring.
3.3
Wiring Information
A 10-wire cable is embedded in the back inlay.
Connect this product to 12 to 24 VAC/VDC connections using the white and red wires. Make sure that, if needed, the unit is grounded (GND) correctly.
To wire the unit correctly, refer to Table 1.
Table 1: Wiring Color
Wire Color
White
Connection
V IN (12-24 VAC/VDC)
Red
Brown
Purple
Grey
Orange
Blue
Yellow
Green
Black
V IN (12-24 VAC/VDC)
N.C. 1
COM1
N.O. 1
N.C. 2
COM2
N.O. 2
Input
Ground/Shield
The COM must be connected to the adjacent N.C. or N.O. relay.
4.
Jumper Settings
The EX-07/EX-17 has 8 internal jumpers (Figure 4).
Figure 4: Jumpers
These are connected to enable the following various features::
Setting the relay mode (JP1)
Setting the LED behavior (JP2, JP3)
Setting the LED color mode (JP4)
Setting color fading mode (JP5)
Setting the factory programming mode(JP6)
Setting the buzzer mode (JP7)
Setting the blink mode (JP8)
If the black cover is on the jumper, the jumper is Short (S). If the black cover is off the jumper, the jumper is Open (O).
2
4.1
4.2
Relay Mode Jumper
Set the relay mode by setting JP1:
JP1=O: (default) Relay pulses for the time period set by the potentiometer.
JP1=S: Relay toggles between on and off.
Buzzer Mode Jumper
The unit is equipped with a built-in buzzer. Set the buzzer mode by setting JP7:
JP7=O: (default) Buzzer OFF. No sound generated on any event.
JP7=S: Buzzer ON.
Blink input mode: The buzzer pulses following the lighting duty cycle.
Any other state: The buzzer beeps for 300 ms when the button is pressed.
4.3
Blink Mode Jumper
This feature functions with the Input wire (green).
To enter blink mode, JP8 must be shorted to enable entering blink mode and the blink input wire (green) must be grounded to set the LED illumination according to the table above.
JP8=O (default): Timer. The timer is off. The timer turns on when the button is pressed.
JP8=S: Blink. Normally off. If there is a continuous external input signal, there is continuous flashing (500 ms/30% DC)
5.
Testing the REX Button
After connecting the wires and setting the jumpers, test the EX-07/EX-17
REX button before screwing in the face plate.
To test the REX button:
1.
Press the button on the EX-07/ EX-17.
2.
Check to see if the electronic lock or lock strike opens and the desired light and timer settings activate.
3.
Make sure the LED returns to its base color.
4.4
LED Behavior Mode Jumpers
Set the LED color and behavior modes by setting JP2, JP3 and JP4.
Table 2 illustrates LED color and behavior in a combination of jumper
mode configurations:
Table 2: LED Color and Behavior
JP2 JP3 JP4 Standby color
O O O Red
O
O
O
S
S
S
S
O
S
S
O
O
S
S
S
O
S
O
S
O
S
Green
Off
Off
Off
Red
Green
Red
Active color
Green
Red
Green
Red
Off
Red
Green
Green
Blink color
Red flashing
Green flashing
Green flashing
Red flashing
Red flashing
Red flashing
Green flashing
Red flashing
Description
Changes from red to green (default)
Changes from green to red
Changes from nolight to green
Changes from nolight to red
No light
Always red
Always green
Acts as default
4.5
Factory Programming Mode Jumper
Set the factory programming mode by setting JP6. Factory programming mode is not for regular use.
3
Limited Warranty
The full ROSSLARE Limited Warranty Statement is available in the Quick
Links section on the ROSSLARE website at www.rosslaresecurity.com
.
Rosslare considers any use of this product as agreement to the
Warranty Terms even if you do not review them.
Contact Information
United States and Canada
Rosslare Security Products, Inc.
Southlake, TX, USA
Toll Free: +1-866-632-1101
Local:
Fax:
+1-817-305-0006
+1-817-305-0069 [email protected]
Europe
Rosslare Israel Ltd.
Rosh HaAyin, Israel
Tel: +972-3-938-6838
Fax: +972-3-938-6830 [email protected]
Latin America
Rosslare Latin America
Buenos Aires, Argentina
Tel: +54-11-4001-3104 [email protected]
China
Rosslare Electronics (Shenzhen) Ltd.
Shenzhen, China
Tel: +86-755-8610-6842
Fax: +86-755-8610-6101 [email protected]
Asia Pacific, Middle East, Africa
Rosslare Enterprises Ltd.
Kowloon Bay, Hong Kong
Tel: +852-2795-5630
Fax: +852-2795-1508 [email protected]
India
Rosslare Electronics India Pvt Ltd.
Tel/Fax: +91-20-40147830
Mobile: +91-9975768824 [email protected]
www.rosslaresecurity.com
4
advertisement
Key Features
- Heavy-duty
- Non-sparking
- Non-magnetic
- Corrosion resistant
- Illuminated
- Anti-vandal
- Timed
- Digital
- Solid state switch technology
- Built-in buzzer