Anco Batch Pasteurizer Installation Manual

Anco Batch Pasteurizer Installation Manual

Anco Batch Pasteurizer is an insulated jacketed tank equipped with a drive and motor, agitation, adjustable ball feet, Anderson thermo-well, 2" valve outlet, multiple ports, lifting lugs, and CIP spray ball. It comes in standard and custom sizes from 50 to 2,000 gallons. You can use it for heating and cooling milk and other food, dairy, beverage or chemical products.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Anco Batch Pasteurizer Installation Manual | Manualzz

ANCO BATCH PASTEURIZER –INSTALLATION MANUAL

A N C O E QU I P M E N T

1 0 7 0 E . G L E N B R OOK D R I V E

P U L A SKI , WI 5 4 1 6 2

WWW. A N C OE QU I P M E N T. C OM

Table of Contents

About our Batch Pasteurizer

Tank Specifications and Options

Batch Pasteurizer Overview

Cleaning Instructions

Passivating your Tank

Sizing your Boiler

8

9

Jacket Port Install 10

Leak Detection Valve Install, Handling & Maintenance 13

3

4

5

7

Air Space Heater

Anderson Chart Recorder Overview

Spray Ball Maintenance and Technical Information

Test Run Procedure

Pasteurizing Procedure

Warranty

Conclusion

15

16

18

20

21

28

29

1/5/2016

2

About Our Batch Pasteurizer

Batch pasteurizers are insulated, jacketed tanks. When used with a boiler & chilling system

Pasteurization Vats can heat and cool almost any food, dairy, beverage or chemical products.

The most common use for batch pasteurizers is in the dairy industry for milk pasteurization. The

Anco Batch Pasteurizer comes in standard and custom sizes from 50 to 2,000 gallons.

The Anco Combo Vat is designed for the small cheese maker; it allows for milk pasteurization and cheese making in one vat.

How are our Pasteurizers Built?

We start with either 304 or 316 (depending on the product being produced) 11 gauge stainless steel interior wall.

The jacket is dimple plated and wrapped in two inches of polyurethane insulation. The exterior wall is 14 gauge with choice of No. 2 or No. 4 finish.

Most tanks come standard with a drive and motor, agitation, adjustable ball feet, Anderson thermo-well, 2" valve outlet, multiple ports, lifting lugs, and CIP spray ball.

Other features also available are: variable speed drive (VSD), leak detect valve, air space heater, Anderson recorder and temperature probes.

1/5/2016

3

Batch Pasteurizer Specifications and Tank Options

Capacity Range:

Tank Top:

50-2,000 gallon

Flat top with removable covers, Wing-Top, Dome Top with

Manhole

Slight Slope Tank Bottom:

Tank Interior Shell: Cylindrical vertical, 11 gauge type 304 or 316 stainless steel

Interior Finish:

Jacket:

Insulation:

Number 4 finish food grade

(1-4 ) Zones available, 304 full vertical side wall and bottom dimple plate jacket

2" polyurethane insulation

Tank Exterior Shell: Cylindrical vertical, 14 gauge type 304 or 316 stainless steel

Exterior Finish:

Outlet:

Number 4 finish

1.5” or 2” leak detect valve ready

Agitation:

Ports:

Leg:

Vertical or Bottom sweep, Side Scrape type agitation available,

Removable agitator shaft, also available. Euro-Drive and Motor with or without variable speed drive control

2" TC and 1.5

” TC and Inlet port (s) available

Three or Four stainless steel pipe legs with adjustable ball feet

1/5/2016

4

Batch Pasteurizer Overview

Tank Inspection

Anco Equipment preforms thorough inspection before each tank is shipped to insure every piece is in good working order. We ask all our clients to do the same.

Immediately upon arrival of the equipment, confirm the tank has not been scratched, dented, or missing any parts during transit. Call Anco Equipment immediately if you find something wrong with your order.

Prepping Instructions

Cleaning your vat: after the manufacturing and shipping process, it is important to thoroughly wash and degrease your vat. Please see further in this manual or contact your chemical cleaning supplier for recommendations.

Prior to tank use: be sure to clean and sanitize the vat, pump, outlet valve, supply lines and spray balls (if present). If you decide to use a chemical based cleaning process; be sure to follow all manufacture’s instruction. To avoid pitting of your equipment NEVER

let highly chlorinated water stand more than ten minutes.

Passivation is a method of maximizing the inherent corrosion resistance of the stainless alloy we recommend using this technique to preserve the tank. Please see further instructions in this manual or contact your chemical cleaning supplier for instructions.

Boiler Installation Instructions

Please use a licensed boiler technician or licensed Pipe Fitter when installing the tank.

The tanks dimple plated jacket is designed to heat and/or cool with Glycol, a hot water boiler or a steam boiler system. The jacket is tested and rate for 70 maximum pounds per square inch (PSI). Low pressure boilers are recommended. If you are using a high pressure boiler confirm with your state rules and regulations that no additional stamps or documentation are required (example: ASME).

A properly sized boiler can have your product at pasteurizing temperature within 25 minutes or less. You will need a licensed plumber or boiler technician to install your boiler system. There should be pressure valves installed to protect the tank jacket from reaching more than the maximum PSI allows. Please see further in this manual for proper boiler sizing.

If you are heating with steam; the steam inlet is the top port of jacket on the side. If the tank has 2 or more zones the bottom zone ports are interchangeable. See diagram further in this manual.

If you are heating or cooling with water or Glycol the inlet is the bottom or lowest port of jacket. If the tank has 2 or more zones, the bottom zone ports are interchangeable. See diagram further in this manual.

1/5/2016

5

Motor/Gearbox

A licensed electrician is needed to hard wire the motor/gear and variable speed drive

(if applicable).

Frequently check the oil level plug and add oil if needed. Food grade oil is recommended.

Gaskets

Only food grade gaskets can be used on all ports and valves. Gaskets should be inspected regularly for cracks or worn areas. The gaskets must be replaced every 18 months for moderate use or when worn or damaged.

Clean In Place-Spray Ball Cleaning Nozzles

Unless otherwise noted, your tank is equipped with (2) Food Grade spray ball nozzles.

Please see diagram further in this manual for step by step cleaning and maintenance procedure.

Leak Detection Valve Instructions and Maintenance

Each valve purchase includes a food-grade gasket and a tube of PetroLube.

To install; clean the area of the tank where the gasket is place. Apply PetroLube to both sides of the gasket and place on to the tank bolts. Lubricate the inner guts of valve before setting in place. The PetroLube is a food-grade lubricant and is allowed to have product contact. Please see diagram further in this manual.

Also find video reference on YouTube under Anco Equipment.

Adjustable Ball Feet

• Any threads showing on the tank’s adjustable ball feet must be sealed with a food grade sealant.

Exterior Threaded Ports:

• When connecting any process lines or tubing to the tank’s threaded ports; use a Food

Grade Anti-Seize & Lubricating Compound on the threaded area. This will help resist acid, chemical corrosion & oxidation. Follow manufactures instructions.

Electric Airspace Heater

The electric airspace (if needed) will be installed on the lid or roof of tank. Please use a licensed electrician for proper installation.

1/5/2016

6

Cleaning your Batch Pasteurizer

Degreasing your tank prior to passivation is a very simple but important step in preparing your tank. You may consult your chemical supply provider or use these steps below.

1.

Fill tank about 10% full with hot water.

2.

Add degreaser.

3.

Using a circulating pump, rotate the water from the tank outlet to the CIP spray balls.

4.

Run the cycle for 15 minutes.

5.

Drain soapy water and rinse.

1/5/2016

7

Passivating your Batch Pasteurizer

Passivation is a chemical treating process that will maximize the longevity of the stainless steel. We recommend completing this process to preserve the tank’s longevity.

Below are two companies that supply the chemicals for passivation. You may also already have a chemical provider you wish to use. We have also included their step by step instructions either as an additional attachment (if received electronically) or further in this pamphlet (if received as a printed document).

Stellar Solutions

4511 Prime Parkway

McHenry, IL 60050

Phone: (847) 854-2800

Fax: (847) 854-2830 www.citrisurf.com

Ecolab

Food & Beverage Processing

Customer Service: 800-392-3392 www.ecolab.com

1/5/2016

8

Sizing your Boiler

1. A properly sized boiler is the key to pasteurizing in a quick timely manner. Since the tank

jackets are only rated to 70 PSI (pounds per square inch) we recommend using a hot water or low-pressure steam boiler. Check the boiler regulations in your state before purchasing a boiler.

2. For Hot Water Boilers: The recommended GPM (gallons per minute) is 25-30 with a

maximum of 50 GPM.

3. Boiler MUST be installed by a licensed pipe-fitter or plumbing professional

500

600

800

1,000

1,200

1,500

Tank Size in Gallons

Side Jacket in Gallons

Side Jacket in Sq. Ft.

50 1.8

12

Bottom Jacket in Gallons

1.4

75

100

2

3

13

18

1.4

1.4

150

200

300

400

4

5

7

8

26

33

42

48

1.4

1.4

2

2

9

10

11

12

16

18.5

54

60

68

82

136

166

3

3

3

3.5

4

4.5

Bottom Jacket in Sq. Ft.

7

7

7

7

7

11

13

17

18

19

20

22

24

2,000 22 204 5 26 3,000,000

Note: Figures below are based on a standard tank and may vary if tank dimensions change.

BTU's

Required

100,000

150,000

200,000

265,000

350,000

525,000

600,000

750,000

900,000

1,200,000

1,500,000

1,800,000

2,250,000

1/5/2016

9

Inlet & Outlet-Single Zone Jacket Install

Note: boiler MUST be installed by a licensed boiler or plumbing professional.

Steam must always enter from the top inlet jacket and exit from the bottom or lower jacket port.

Water or Glycol must always enter from the lower inlet port of the jacket and exit from the top or higher jacket port.

1/5/2016

10

Inlet & Outlet-Two Zone Jacket Install

Note: boiler MUST be installed by a licensed boiler or plumbing professional

Steam must always enter from the top inlet jacket and exit from the bottom or lower jacket port.

Bottom ports are interchangeable.

Water or Glycol must always enter from the lower inlet port of the jacket and exit from the top or higher jacket port.

1/5/2016

Bottom ports are interchangeable.

11

Inlet & Outlet-Three Zone Jacket Install

Note: boiler MUST be installed by a licensed boiler or plumbing professional

Steam must always enter from the top inlet jacket and exit from the bottom or lower jacket port.

Water or Glycol must always enter from the lower inlet port of the jacket and exit from the top or higher jacket port.

1/5/2016

12

Leak Detection Valve

Each Valve Purchase includes a 2” PMO Leak Detect Valve, a Plastic Gasket, and a Tube of Food Grade Petrol Gel.

Installing the Valve

1.

Apply Petrol Lube to the gasket and stick it to the base of tank.

2.

Apply generously to the front of gasket and back of valve.

3.

Apply Lube inside the guts of the valve.

4.

Test the valve.

5.

If there is a leak apply lube to leaking area.

1/5/2016

13

Proper Valve Maintenance & Handling

1/5/2016

14

Electric Airspace Heater

The 1,250 watt element requires 16 amps and needs to be wired to single phase

220v. It should be positioned in the tank angled to the center making sure it does not interfere with the agitator shaft or CIP spray balls.

The Air Space Heater fits into a

3” Sanitary ferrule and element is self supporting.

The Rheosat control allows you to adjust the amount of electrical current running to the heating element and control the heat of the air space. The Rheosat needs to be installed by a licensed electrician.

15

1/5/2016

Anderson Chart Recorder and Temperature Probes

1/5/2016

16

Installation Information

A hard copy of the complete installation manual will be included with your

Anderson Equipment.

1/5/2016

17

Spray Ball Installation and Maintenance

1/5/2016

18

Spray Ball Specification Sheet

1/5/2016

19

Running your Batch Pasteurizer

Once your boiler and electrical components are installed and your tank is degreased and passivated; we recommend running a test batch with water prior to running your product. This will also help get a feel for your boiler to maintain a steady temperature.

The agitator should be operating at all times while product is being heated during the pasteurization cycle. Always fill tank from the top of your pasteurizer using the product inlet.

The Product and Airspace thermometer along with chart recorder should be on and in place.

Hot water or steam should be reduced shortly before reaching pasteurizing temperature or the temperature may overshoot. This will give you the opportunity to make any final adjustments to the pressure valves, pumps, timing, etc.

Closely monitor both the product and airspace temperature recordings until full pasteurization of product is reached in 30 min per the PMO guidelines. Please remember if any manholes, wing doors, or ports are opened during the 30 min pasteurization process, you will have to start your 30 min pasteurization over.

Turn the air space heater off at the end of pasteurization before starting to cool the vat. Keep covers on until product is withdrawn from the vat unless you will be using the vat for further production.

To cool the milk following pasteurization, the water or steam should be turned off and drained before adding water of 50ºF or lower while continuing to stir. Using well water to cool down your product first is a great way to gradually bring down the temperature before using your chilling unit.

1/5/2016

20

Batch Pasteurizing Standards

(Rules and procedures may vary from state to state, please check with your local inspector)

1. All components must be added to the batch prior to beginning pasteurization. This includes liquid sugar and sweeteners, water, milk powders and all other flavorings, stabilizers and vitamins. Certain flavoring ingredients may be added after pasteurization.

These include ingredients that have a water activity of 0.85 or less, high acid content, dry sugars, fruits and roasted nuts, safe and suitable bacterial culture organisms and flavorings containing a high alcohol content. Fruits and vegetables may be added to cultured products having a pH of 4.7 or less. Such ingredient addition shall be done in a sanitary manner and the ingredients must be of safe and wholesome quality.

2. Pasteurization must be performed in properly designed and operated equipment that ensures that every particle of product will be held continuously for the minimum time and temperature. The product should be heated to pasteurization temperature in as short a time as practicable and in no case should this time exceed 4 hours. Following pasteurization the product must be cooled to 45°F or less as soon as possible. The only exception is for cultured product processing.

3. If, for any reason the lid or any cover is lifted or mechanical failure of any kind occurs after beginning the pasteurization process, the timing process must be restarted and notes to that effect must be made on the recording chart by the operator.

4. The official thermometer is the indicating thermometer and the recording thermometer functions only to provide a record of the pasteurization cycle. The operator must verify the accuracy of the recording thermometer, for each batch, with the indicating thermometer. No batch of milk shall be pasteurized unless the sensors of both thermometers are covered.

5. The air space thermometer reading must also be recorded on the recording chart during pasteurization. To assure the minimum air space temperatures are being maintained, the air space indicating thermometer shall be read at the beginning and at

the end of the holding period. The air space temperature must never be less than 5°F

above the minimum legal pasteurization temperature required for the product in the vat.

6. Recording charts must be used only for the length of time it has been designed for.

Overlapping information on circular charts is never acceptable. Required information on the chart must be legible and meet all the requirements of the PMO.

7. The outlet valve is designed to detect and expel any leakage past the valve seat and is

close coupled to prevent cold pockets of product from accumulating in the valve or piping. At no time during the pasteurization cycle or following may the outlet piping be

directly attached to any line or vessel containing raw milk or any other contaminating

substance.

21

1/5/2016

Assurance of Holding Periods

1. Vats must be operated so that every particle of milk is held for at least 30

minutes at or above the minimum required temperature for the specific product processed.

2. When the milk product is heated to pasteurization temperature in the vat and is partially cooled in the vat before opening the outlet valve, the recorder chart must show at least 30 minutes at or above the minimum pasteurization

temperature.

3. When the milk product is preheated to pasteurization temperature prior to entering the vat, the recorder chart must show a holding time of 30 minutes

plus the filling time of the vat from the level of the recorder bulb sensor to the

maximum level of normal operation.

4. When cooling is begun after the outlet valve is opened or is done entirely outside the vat, the chart must show a holding time of 30 minutes plus the time

necessary to empty the vat to the level of the recording thermometer bulb.

5. The operator must indicate filling and/or emptying times on the chart by inscribing the start and end of the official 30 minute holding time.

6. Vat pasteurization charts must clearly show the four identifying holes (marks) which verify the chart has not been rotated or manually turned to give a false time line accuracy.

1/5/2016

22

PMO Guideline for Dairy Products

Taken from PMO Guideline Book

1/5/2016

23

Indicating and Recording Thermometer

VAT PASTEURIZER THERMOMETER CRITERIA

VAT PASTEURIZATION – CRITICAL CONTROL POINTS

1. Time and temperature requirements

2. No temperature abuse

3. Covers in place during operation

4. Vat construction within compliance

6. No ingredients added after pasteurization

7. Product protected after pasteurization

1/5/2016

24

1.Indicating thermometers shall be mercury actuated, direct reading type, scaled to a minimum of 0.625 of an inch, with a span of not less than 25 F. The span must include the pasteurization temperature (plus or minus 5° F) and be graduated in 1° F and accurate to within 0.5°F.

2.The sensing bulb of the indicating (official) thermometer must be designed to extend fully into the product during pasteurization.

3.An approved air space must be provided that is graduated in 2-degree maximum increments and accurate to pus or minus 1°F. The bottom of the bulb chamber must not be less than 2 inches or more than 3.5 inches below the underside of the top enclosure or cover. The bottom of the bulb must never be less than 1 inch from the top surface of the product during pasteurization.

4.The vat must be equipped with a recording thermometer graduated in 1°F increments between140° and 155°F. The chart must be graduated in time scale divisions of not more than 10 minutes for a maximum record of twelve hours and designed for the recorder used.

5.On vats used solely for pasteurization at temperatures above 160°F, the recording chart may be graduated in 2°F within a 150° to 170°F range. The chart for this type of vat may be graduated in 15 minutes for a maximum of 24 hours.

6. Review the recording charts for the following information: (PMO, Part II,

Section 7, item 16p(E)(1)(b)).

1. Date

2. Chart # if more than one used during a product day

3. Name or number of pasteurization unit

4. Cut-in and cut-out temperature recorded at the beginning of the run, with a reference mark

5. Indicating thermometer temperature at a given time or reference point as indicated on chart

6. Position of FDD (Forward Flow or Diverted Flow) recorded by mechanical "event" pen on the thermal limit controller

7. Amount and identification of each product noted on the chart

8. Record of and reason for each unusual occurrence if any

9. Signature or initials of operator

10. Name of plant

11. Record of Quality Control

1/5/2016

25

General Cleaning and Sanitation of Pasteurizing Equipment

Milk-stone is a hard deposit or encrustation that is a combination of milk solids and washing powder that may build on milk equipment. The minerals contained in hard water also contribute to its formation. It is a chemical reaction that is accelerated by heat causing more deposits on heating surfaces than elsewhere. Aside from these contributing factors the primary cause of milk-stone is improper cleaning.

Phosphatase Test

– Is a test used to determine the effectiveness of the pasteurization process. Phosphatase is an enzyme normally present in raw milk that is easily destroyed or inactivated by pasteurization. When milk that is contaminated with raw product or not held at the proper temperature long enough active phosphatase will be present in larger amounts than found in properly pasteurized milk.

A positive coliform test is indicative of post-pasteurization contamination. Coliform organisms are easily killed by pasteurization. The following steps can prevent postpasteurization contamination: Clean and sanitized equipment and containers. No hand capping or bottling or other handling of milk equipment. Prevent exposure to potential contaminate such as flies, dust, dirt, drip or splash.

Milk spoilage, bacterial breakdown of milk proteins:

Sour - milk held at temperature of 65-75 will allow souring type organisms grow.

Bitter - milk that is held at temperatures below 50 would more often become bitter for the same reason.

Ropy - thermoduric spore-formers that may survive the heat process, traced to stagnant water on the farm.

Sweet curdle - fermentation and coagulation of milk with no acid production by organisms surviving the heat process that may destroy acid producing organisms.

Thermoduric -organisms that survive pasteurization temperatures. Thermo-philicorganisms that grow freely in milk at temperatures above 140°F

Sanitation - mere cleaning of equipment does not remove or destroy all disease causing organisms that may have been present. Even very small numbers remaining may grow to dangerous proportions since many grow rapidly in milk. All milk equipment must be treated with a sanitizing agent just prior to usage. Cleaning must be thorough before sanitation can be effective since the presence of organic material such as, milkstone and soil can inactivate the sanitizer.

The number and type of bacteria present in raw milk, faulty equipment or soiled, unsanitary contact surfaces of equipment may influence efficiency of pasteurization.

1/5/2016

26

Batch Pasteurizer Specifications and Tank Options

1. Steam

This method can be used successfully only in confined areas. All parts of equipment must be exposed to a temperature of at least 170°F for at least 5 minutes.

2. Hot Water

This method is difficult to use on assembled equipment, particularly where hot water flows over a surface cooler. The temperature and exposure time is the same as steam.

3. Chemical

An approved chemical sanitizing solution, such as chlorine or quaternary ammonia is circulated or pumped through assembled equipment. Equipment may also be dipped in a solution to expose all the surfaces to the sanitizer. The strength of a chlorine solution should be 100 parts per million (ppm) for 30 seconds of contact time or 50 ppm for 2 minutes contact time.

1/5/2016

27

Warranty

Equipment & Parts manufactured by ANCO Equipment, LLC:

ANCO Equipment, LLC warrants to the first user (the “Buyer”) that the equipment manufactured by ANCO will be free from factory defects in materials and workmanship under normal use and proper maintenance for a period of twelve (12) months from the date the equipment is shipped from its facility.

Parts, Components & Materials manufactured by others:

Parts, components and materials manufactured by others are warranted only to the extent of the warranty given to ANCO by the manufacturer of such parts, components and materials. Said manufacturers’ sole judgment shall determine the extent of allowance for, or replacement of, any such parts claimed defective.

ANCO Equipment, LLC does not warrant the corrosive resistance of stainless steel nor other metal parts for any purpose whatsoever.

Company Obligation:

ANCO Equipment, LLC’s obligation under its warranty is strictly and exclusively limited to the repair or replacement, at the company’s location in Pulaski, Wisconsin, of such components of its manufacture as are found by the company to be defective in materials or workmanship on the condition that the buyer gives prompt written notice to the company of any claimed breach of warranty within such twelve (12) month period and delivers to the company the claimed defective component within such time period or a reasonable time thereafter. All costs of packing and shipping claimed defective components and replacement and replacement or repaired components shall be paid by the buyer. The company reserves the right to satisfy its warranty obligation in full by the payment of the full purchase price upon return of the equipment to it at Pulaski,

Wisconsin. IN NO EVENT SHALL THE COMPANY BE HELD LIABLE FOR CLAIMS

(BASED ON BREACH OF EXPRESS OR IMPLIED WARRANTY, NEGLIGENCE, OR

OTHERWISE) FOR ANY OTHER DAMAGES, WHETHER DIRECT, IMMEDIATE,

INCIDENTAL, FORESEEABLE, CONSEQUENTIAL, OR SPECIAL, INCLUDING

DAMAGES ARISING OUT OF PERSONAL INJURIES.

The Company’s warranty stated herein cannot be modified except by a writing signed by an officer of the Company.

1/5/2016

28

Anco Equipment strives on 100% satisfaction on all their equipment. For any additional questions or concerns please check out our website at www.ancoequipment.com

or call at (920) 569-3530.

1/5/2016

29

advertisement

Key Features

  • Insulated jacketed tank
  • Standard and custom sizes
  • 50 to 2,000 gallons capacity
  • Drive and motor, agitation
  • Adjustable ball feet, Anderson thermo-well
  • 2" valve outlet, multiple ports, lifting lugs
  • CIP spray ball

Frequently Answers and Questions

How do I clean my Anco Batch Pasteurizer?
After the manufacturing and shipping process, it is important to thoroughly wash and degrease your vat. See Cleaning Instructions section in the viewed document for details.
What type of boiler does the Anco Batch Pasteurizer work with?
It is designed to heat and/or cool with Glycol, a hot water boiler or a steam boiler system. The jacket is tested and rated for 70 maximum pounds per square inch (PSI). Low pressure boilers are recommended.
What are the standard features of the Anco Batch Pasteurizer?
Most tanks come standard with a drive and motor, agitation, adjustable ball feet, Anderson thermo-well, 2" valve outlet, multiple ports, lifting lugs, and CIP spray ball.
What are the available options for the Anco Batch Pasteurizer?
Other features also available are: variable speed drive (VSD), leak detect valve, air space heater, Anderson recorder and temperature probes.

Related manuals

Download PDF