Below you will find brief information for Heating Mats. Heating Mats are designed to provide comfortable floor heating in various applications, including kitchens, bathrooms, and living rooms. These mats consist of a heating cable attached to a fiberglass fabric, ensuring efficient heat distribution. The installation process involves laying the mats directly onto the floor surface, securing them with adhesive tapes, and connecting them to the electrical system.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
INSTALLATION MANUAL / NÁVOD NA INSTALACI
N206/R09 (13.08.15)
LD
CABEL HEATING MATS/ PODLAHOVÉ TOPNÉ ROHOŽE
•
Heating mats may be operated only as a part of building structures.
Fixing the heating cable to the fiberglass fabric during manufacture by gluing is regarded to be only a temporary bond. The heating mat is intended for installation in wet construction processes (concrete, adhesive and “self-leveling” sealing materials based on cement fulfilling thermal flexibility requirements – during application it is necessary to follow the manufacturer’s instructions). When in use, the heating mat must be in full contact with these materials and free from air bubbles.
•
The mat may be adjusted only as shown in pictures 1 – 3, and in no case may it be shortened. You may shorten only the cold connection ends, as required. The connection joining the cold end and the heating cable may not be installed in a bend. The heating cables of the heating mats may neither touch nor cross one another. The minimum distance between the cables is 30 mm. If the heating or power supply cables are damaged, they must be replaced or repaired by the manufacturer, its service technician or a similarly qualified person in order to prevent a dangerous situation from arising. Do not use nails or screws to install the cables!
• When installing the cables, the radius of a bend in the cable must not be smaller then four times its diameter.
• The heating cable must be supplied with electricity by means of a residual current circuit breaker with rated actuating current of IΔn≤30mA. We recommend that each heating unit/circuit be equipped with a separate residual current device.
•
For safety reasons, heating mats may not be installed in walls.
•
The heating mats may be stored at temperatures from +10°C to +35°C and installed at temperatures from +5°C to +30°C. When in operation, they may not be exposed to temperatures exceeding 70°C.
•
During removal from packaging , manipulation and installation of the mat take special care to avoid mechanical damage to the mat – check the heating cable visually before pouring the building material
.
•
Topné rohože smí být provozovány jen jako součást stavebních konstrukcí. Fixace topného kabelu ke skelné tkanině lepením je považována jen za dočasnou fixaci, topná rohož slouží pro instalaci v mokrých stavebních procesech (beton, lepící a „samonivelační“ tmely na cementové bázi splňující požadavky na tepelnou flexibilitu
— při aplikaci je nutné řídit se návodem výrobce) a při provozu musí být s těmito hmotami v dokonalém kontaktu bez vzduchových mezer.
• Rohož může být upravována výhradně dle obrázků 1–3, v žádném případě nesmí být krácena. Kráceny dle potřeby mohou být pouze studené připojovací konce. Spojka spojující studený konec a topný okruh nesmí být instalována v ohybu. Topné kabely topných rohoží se nesmějí dotýkat, ani křížit, vzdálenost topných kabelů od sebe je min. 30mm. Jestliže je topný kabel nebo napájecí přívod poškozen, musí být nahrazen nebo opraven výrobcem, jeho servisním technikem nebo podobně kvalifikovanou osobou, aby se zabránilo vzniku nebezpečné situace. Kabely neinstalujte pomocí hřebíků a vrutů!
• Při instalaci musí být dodržen požadavek, že poloměr ohybu kabelu nesmí být menší než čtyřnásobek jeho průměru.
• Topná rohož musí být napájena přes proudový chránič se jmenovitým vybavovacím proudem I Δ n ≤ 30mA. Doporučujeme každý topný celek / okruh topení vybavit samostatným proudovým chráničem.
• Topnou rohož je z hlediska bezpečnosti zakázáno instalovat do stěn.
• Topná rohož smí být skladována při teplotě +10°C až +35°C a instalována při teplotě +5 až +30°C. Při provozu nesmí být vystavována teplotám vyšším než 70°C.
• Při vybalování, manipulaci a instalaci rohože dbejte zvýšené opatrnost, aby nedošlu k mechanickému poškození rohože — zkontrolujte prohlídkou topného kabelu před zalitím stavební hmotou.
•
The heating mat may not be installed on irregular surfaces
.
• The heating mat is primarily intended for installation with the supporting material facing the base. It can, however, be installed the other way round.
•
In case that mats are laid in an area larger than 20m 2 or with a diagonal greater than 7m, it is necessary to account for expansion of the foundation materials. The heating cable must not cross the expansion joints. The nonheating connecting cables located at the expansion joints must be laid loosely in a protective tube. All installed elements – cold connection end, thermostat’s probe – where they pass from the wall to the floor must be placed in installation tubes and must allow for movement of the floor and wall relative to one another.
•
To allow for expansion around the periphery of the room between the baseboards and the floor tiles, use an expansion profile or fill the spaces with silicone sealing cement. The distance between the heating mat and the wall must not be less than 50mm.
•
The mat must not be placed either under such furnishings as bathtubs, shower baths, toilets and the like or under furniture that does not allow air to circulate. The maximum thermal resistance between the heating part and the room may be R=0.15 m 2 K/W.
•
The installation must allow for disconnecting the mat or mats at both poles.
The minimum distance of disconnected contacts must be 3,5mm.
• The label on the cold end of the heating mat shows the serial number and production date. The label on the mat’s packaging shows type, dimensions and area of the mat, total output, output per 1m supply voltage and electrical resistance.
2 , as well as the mat’s
•
Before and after laying the mats, it is necessary to measure the resistance of the heating circuit. The measured values should be equal. Record the measured values in the certificate of warranty.
• Before and after laying the cables, it is necessary to measure the insulation resistance between the heating conductor and the protective braiding. This measured value may not be less than 0,5MΩ. Record the measured values in the certificate of warranty.
• Before opening the package with the heating mat, it is necessary to check whether the data on the label is in accordance with your requested product.
• In case of any discrepancies, you should report these immediately to the manufacturer or supplier and discontinue the work completely.
•
You must draw the scheme of the heating mat layout in the certificate of warranty, indicating the exact distance of the connections of the supply cable and heating part from the walls of the building. Record the serial number and production number of the heating mat that are stated on the label on the mat’s cold end, then insert/stick this label into the connection box.
• The supplier must inform other construction suppliers about the heating unit installed in the floor and of the related risks.
•
A sheet of paper with information about the heating system must be permanently kept in the switch box of the heating system and passed on to any new owner or tenant.
•
When installing the mats, the HD 3844-7-753 ;
EN 50559 standard requirements must be met.
•
The product is produced according to the EN 60335-2-96/I EC 60335-2-96 standard and must be installed in accordance with the national regulations for electrical installation.
• Topná rohož se nesmí instalovat na nepravidelné povrchy.
• Primárně je topná rohož určena k instalaci nosnou tkaninou směrem k podkladu. Může však být instalována i obráceně.
•
Při pokládání na plochy větší než 20m 2 nebo s úhlopříčkou větší než 7m je nezbytné respektovat dilataci podkladových materiálů.
Topná rohož nesmí přecházet přes dilatační spáry. Připojovací netopné kabely musí být v místě dilatačních spár volně uloženy v ochranné trubce. Přechod veškerých instalací – studený konec, sonda termostatu – ze stěny do podlahy musí být provedeny v instalačních trubkách a umožňovat vzájemný pohyb podlahy a stěny.
• Pro obvodovou dilataci mezi soklem a dlažbou použít dilatační profil, nebo spáru vyplnit silikonovým tmelem. Rohož musí být nejméně 50mm ode zdi.
• Rohož nesmí být kladena pod zařizovací předměty jako jsou vany, sprchové kouty, WC apod., jakož i pod nábytek neumožňující volné proudění vzduchu. Maximální tepelný odpor mezi topnou jednotkou a místností může být R=0,15 m 2 K/W.
• Instalace musí být opatřena zařízením umožňující odpojení rohože, či rohoží v obou pólech se vzdálenosti rozpojených kontaktů nejméně 3,5mm. Odpojení může být zajištěno přístupnou vidlicí nebo spínačem vestavěným do pevného vedení podle předpisů pro instalaci.
• Na štítku umístěném na studeném konci topné rohože je uvedeno výrobní číslo a datum výroby. Na štítku, který je umístěn na obalu rohože je uveden typ, rozměry a plocha rohože, dále celkový výkon, výkon na 1m 2 , napájecí napětí a elektrický odpor rohože.
• Před pokládkou i po pokládce je nutné provést měření odporu topného okruhu. Naměřené hodnoty se musí shodovat. Naměřené hodnoty zapište do Záručního listu.
• Před pokládkou i po pokládce topné rohože musí být provedeno měření izolačního odporu mezi topným vodičem a ochranným opletením – naměřená hodnota nesmí být nižší než 0,5MΩ.
Naměřené hodnoty zapište do Záručního listu.
• Před rozbalením topné rohože je nutno zkontrolovat štítkové údaje, jestli jsou ve shodě s požadovaným výrobkem.
• Jakékoliv neshody ihned oznamte výrobci nebo dodavateli a ukončete veškeré práce.
• Do záručního listu musí být zakresleno uložení topné rohože s označením spojek přívodního kabelu a topné části přesným okótováním od stěn objektu. Do záručního listu musí být opsáno výrobní číslo rohože a datum výroby ze štítku umístěného na studeném konci rohože, tento štítek následně vložte/vlepte do připojovací krabice.
• Dodavatel musí informovat ostatní dodavatele stavby o umístění topné jednotky v podlaze a o rizicích z toho vyplívajících.
• V rozvaděči topného systému musí být stále uložen list s informacemi o topném systému, který musí být při změně majitele nebo nájemce vždy předán.
• Při instalaci musí být dodrženy požadavky normy ČSN 33-2000–7
–753/HD 3844-7-753; ČSN EN 50559.
•
Výrobek je vyroben dle požadavků ČSN EN 60335-2-96/IEC
60335-2-96 a musí být instalován v souladu s národními předpisy pro elektrickou instalaci.
2
• The heating mat can be installed in the bathroom even under zone 0 under the condition that the connector and the end of the heating cable are installed outside this zone. If part of a heating mat extends under zone 0, the mat must be connected via a residual current device with a trip current of 10 mA..
•
An insufficient thermal insulation layer below the heating system may cause significant thermal loss (warmth moving downwards). Recommended thermal insulation is 70–80mm of extruded polystyrene or similar thermal insulation materials. In case of reconstruction, where there is not space to install the thermal insulation to a sufficient depth on the existing tiles, we recommend installing F-boards in a depth of 6mm or
10mm to accelerate the warming of the surface and to reduce the thermal loss. This material is installed into the adhesive sealing cement that was shaped by a notched spreader and the heating mat is placed directly onto its surface. The F-boards do not need to be penetrated.
•
This appliance can be used by children from the age of 8 and older, and persons with lower physical, sensory or mental abilities or a lack of experience or knowledge providing they are under supervision or have been trained in the use of the appliance in a safe manner and understand the possible danger. Children may not play with the appliance.
Cleaning and maintenance by the user must not be carried out by children without supervision.
• The user must be instructed by the supplier regarding the installation of floor heating. This fact is stated on a label which comes with the product and must be glued into the switchboard: this label also informs readers that the making of openings is prohibited, as is covering the floor with furnishings or fittings without leaving at least a 4 cm gap between the floor and the bottom surface.
• Topnou rohož je možno v koupelně instalovat i pod zónu 0 za podmínky, že spojka a koncovka topného kabelu bude instalována mimo tuto zónu. Topná rohož, jejíž část zasahuje pod zónu 0, musí být připojená přes proudový chránič s vybavovacím proudem
10 mA.
• Nepoužitím dostatečné vrstvy tepelné izolace pod topným systémem se vystavujete riziku značných tepelných ztrát směrem dolů.
Doporučená tepelná izolace je 70–80mm extrudovaného polystyrenu a obdobně tepelně izolujících materiálů. Při rekonstrukcích, kde není prostor na stávající dlažbu instalovat dostatečnou tepelnou izolaci, doporučujeme pro zrychlení náběhu povrchu teploty a snížení tepelných ztrát instalovat desky F—board v tloušce 6 nebo
10mm. Tento materiál se instaluje do zubové stěrky lepícího tmelu a topná rohož se klade přímo na něj, není potřeba je předem penetrovat.
• Tento spotřebič mohou používat děti ve věku 8 let a starší a osoby se sníženými fyzickými, smyslovými nebo mentálními schopnostmi nebo nedostatkem zkušeností a znalostí, pokud jsou pod dozorem nebo byli poučeni o používání spotřebiče bezpečným způsobem a rozumí případným nebezpečím.
Děti si se spotřebičem nesmějí hrát. Čištění a údržbu vykonávanou uživatelem nesmí vykonávat děti bez dozoru.
• Uživatel musí být poučen dodavatelem o instalaci elektrického podlahového vytápění. Do rozvaděče musí být vlepen štítek, součásti balení, upozorňující na tuto skutečnost s informací o zákazu dělání otvorů, zákazu zakrývání podlahy zařizovacími předměty, u nichž není mezi podlahou a spodní plochou zajištěna minimální mezera 4cm.
3
1. Description and cennection
•
The heating mat consists of the heating cable attached to a supporting fiberglass fabric.
•
The heating cables should be connected to a 230 V, 50 Hz electrical network. Degree of protection: IP67.
•
LD mats have protective braiding. The cable’s protective braiding meets the standards required of metal grid or metal shield and provides increased protection in spaces where that is required
(bathroom, laundry, etc.) The protective braiding is to be connected to the PE conductor or to a protective grounding connection.
•
LD mat is available in 30cm and 50cm width. (30cm up to
500Wats).
•
LD mats have bottom tapes that are adhesive on both sides. After removing the covering paper from these tapes, the mat can be attached to the base.
•
After unwinding the mat, affix connections to the fabric using the enclosed fastening strips (see picture).
1. Popis a zapojení
•
Topná rohož je sestává z topného kabelu připevněného k nosné sklovláknité tkanině.
• Topné kabely se připojují na soustavu 230V, 50Hz. Krytí IP 67.
• Rohože LD jsou vyráběny s kabelem s ochranným opletením.
Ochranné opletení kabelu zajišuje požadavek norem na kovovou mříž nebo kovový pláš a zajišuje zvýšenou ochranu v těch prostorách, kde je to vyžadováno (koupelny, prádelny apod.). Ochranné opletení se připojuje k PE vodiči nebo k ochrannému pospojování.
• Rohože LD se vyrábějí ve dvou šířích, 30 a 50 cm. (30cm do příkonu 500W).
• Rohože LD mají spodní pásky oboustranně lepící. Po odstranění krycího papíru z těchto pásek je možno rohož přilepit k podkladu.
• Po rozvinutí rohože je nutné spojky připevnit ke tkanině pomocí přiložené stahovací pásky (viz. obrázek)
2. Suggested output and description of installation a) Dimensioning 2. Návrh příkonu a popis instalace
•
In the case of short-period comfort heating of the floor surface (e.g. floor tiling in the kitchen) or the heating of bathrooms, we recommend that 160 W/m 2 LD heating mats are used and that installation is close to the floor surface.
•
If permanent heating of a standard room is considered, 80 W/m 2
LPSV heating mats are more suitable. For the right choice of a heating system, we need to know the value of heat loss from the building. The installed output should correspond to 1.1 to1.3 times the calculated heat loss of the building and it shouldn’t exceed approx. 100 W/m 2 . The installation of output which is higher than this recommended value will accelerate the heating of the floor structure (it will increase the dynamics) but as the temperature of the floor shouldn’t be higher than 27°C for permanent heating, the heating mats will be switched off more often by the thermostat and the real thermal output of the floor won’t be higher. If the output set by the calculation can not be achieved even if heating mats were installed within the whole of the available floor surface, supplementary heating (e.g. radiant panels or direct-heating convectors) has to be used.
a) Dimenzování
• Pokud se jedná o krátkodobý komfortní ohřev povrchu podlahy,
(například dlažby v kuchyni), nebo vytápění koupelny, doporučujeme použít topné rohože LD 160W/m 2 a instalaci blízko povrchu podlahy.
• Pokud se jedná o trvalé vytápění běžné místnosti, jsou vhodné spíše topné rohože LPSV 80 W/m 2 . Pro správnou volbu topného systému musíme znát hodnotu tepelných ztrát objektu. Instalovaný příkon by měl odpovídat 1,1 až 1,3 násobku vypočtených tepelných ztrát objektu , přitom by neměl být vyšší než cca 100 W/m 2 .
Instalace příkonu nad tuto doporučenou hodnotu urychlí prohřívání podlahové konstrukce (zvýší dynamiku), protože však při trvalém vytápění nemá mít podlaha vyšší teplotu než 27°C, topné rohože budou termostatem častěji vypínány a reálný tepelný výkon podlahy se nezvýší. Pokud nelze příkonu stanoveného výpočtem dosáhnout ani při instalaci topných rohoží v celém rozsahu do volné podlahové plochy, musí se použít přídavné topení (např. sálavé panely nebo přímotopné konvektory).
4
b) Installation – direct heating system b) Montáž — přímotopný systém
IUNSTALACE DO LEPÍCÍHO TMELU
INSTALLATION IN ADHESIVE SEALING
CEMENT
•
First read Clause 1 of the General Terms and Conditions.
•
Detailed descriptions of use for the individual materials can be found in the installation manuals for the recommended materials.
PROCEDURE
•
Unroll the heating mat and adjust it according to the area to be heated. Mark the place for the connection and ending of the heating mat on the floor. Roll the mat up again.
•
Create “pockets” in the base material where you will place the connections for the heating and non-heating components.
•
Clean the concrete area, remove any sharp objects and coat it using a suitable penetrating solution.
•
Unroll the heating mat according to the area to be heated.
•
Remove the protective covering from the self-adhesive tapes and attach the mat to the base.
•
Measure the resistance of the heating circuit and the insulation resistance and record the measured values in the certificate of warranty.
•
Use flexible adhesive sealing cement and a flat spreader to smooth the floor surface (be careful not to damage the cable with the sharp edge of the spreader).
•
Before laying the floor tiles, measure the heating circuit values again and record both values in the certificate of warranty.
•
Lay the floor tiles onto the surface.
•
When putting the heating mat into operation, the adhesive sealing cement must be fully hardened (see instruction for use and recommendation from material’s manufacturer).
• Nejprve si přečtěte bod 1. Všeobecné podmínky.
• Detailní použití jednotlivých hmot je uvedeno v návodech přiložených k doporučeným hmotám.
POSTUP
• Rohož rozviňte a upravte dle požadovaného tvaru vytápěné plochy, na podlaze vyznačte místo pro spojku a ukončení topné rohože.
Rohož sviňte.
• V podkladovém materiálu vytvořte „kapsy“ pro uložení spojek topných a netopných částí.
• Podkladovou plochu očistěte, zbavte ostrých předmětů a napenetrujte vhodným penetračním přípravkem.
• Topnou rohož rozviňte dle požadované vytápěné plochy.
• Odstraňte ochranou vrstvu ze samolepících pásek a rohož přilepte k podkladu.
• Proveďte proměření odporu topného okruhu a izolačního odporu, hodnoty zapište do Záručního listu.
• Flexibilním lepicím tmelem za pomocí hladké stěrky srovnejte podlahovou plochu (dbejte, abyste ostrou hranou stěrky nepoškodili kabel).
• Před položením dlažby opět proveďte měření topného okruhu a obě naměřené hodnoty zaznamenejte do Záručního listu.
•
Položte dlažbu.
• Topnou rohož uveďte do provozu až po vytvrdnutí lepícího tmelu, dle doporučení výrobce tmelu.
Direct heating system – new constructions / Přímotopný systém — novostavby
1) Floor tiles / Dlažba
2) Flexible adhesive sealing cement /
3) ECOFLOOR heating mat /
Flexibilní lepící tmel
Topná rohož ECOFLOOR
4) Installation pipe with a floor probe / Instalační trubka s podlahovou sondou
5) Concrate spread layer 40mm
6) Reinforcing steel grid (KARI) /
/ Betonová vrstva cca 40mm
Armovací ocelová sí (KARI)
7) Thermal insulation min. 70–80mm / Tepelné izolace min.
70—80mm
8) Base / Podklad
5
Direct heating system – reconstruction / Přímotopný systém — rekonstrukce
1) New floor tiles / Nová dlažba
2) Flexible adhesive sealing cement / Flexibilní lepící tmel
3) ECOFLOOR heating mat / Topná rohož ECOFLOOR
4) Installation pipe with a floor probe / Instalační trubka s podlahovou sondou
5) F-BOARD thermal insulation (optional) / Tepelné izolace F-
BOARD (není podmínkou)
6) Flexible adhesive sealing cement / Flexibilní lepící tmel
7) Original floor tiles or another base / Původní dlažba nebo jiný podklad
c) Regulation c) Regulace
• Thermostats with a floor probe installed in the heating part of the floor, with at least 30 cm within the heated area, must be used for the thermal regulation of rooms heated using heating circuits/ mats.
•
Place the floor probe of the thermostat as close to the surface of the floor as possible. The probe is placed into a conduit whose end blocked to prevent ingress of building materials.
•
In the case of direct-heating applications, the conduit is placed between the loops of the heating cable, in the centre of a loop. The conduit mustn’t touch or cross the heating cable!
•
The radius of the bend of the conduit between the wall and the floor must be executed in such a way that the probe can be exchanged if needed! The recommended minimum bend radius is
6 cm.
•
The thermostat must be set to the mode: Room + floor temperature limit or Floor.
•
The maximum allowed floor temperature setting (if the datasheet for the covering used doesn’t state a lower value):
• K regulaci místností vytápěných topnými okruhy/rohožemi je nutné použít termostaty s podlahovou sondou instalovanou v topné části podlahy, min. 30cm v topné ploše.
• Podlahovou sondu termostatu klademe co nejblíže povrchu podlahy. Sonda se umísuje do instalační trubky, která je na konci ucpána proti vtoku stavebních hmot.
• U přímotopných aplikací se instalační trubka umísuje mezi smyčky topného kabelu, ve středu smyčky. Instalační trubka se nesmí dotýkat, křížit s topným kabelem!
•
Poloměr ohybu instalační trubky mezi stěnou a podlahou musí být proveden tak, aby bylo možné sondu v případě potřeby vyměnit!
Doporučený minimální poloměr ohybu 6cm.
• Termostat musí být nastaven v režimu: Prostor + limit teploty podlahy nebo Podlaha.
• Maximální dovolené nastavení teploty podlahy (pokud technický list použité krytiny neuvádí nižší hodnotu):
27°C - dlouhodobě obývané místnosti
35°C - krátkodobě obývané místnosti s dlažbou
27°C - rooms which are used for longer periods
35°C - rooms used for shorter periods, with floor tiling
6
3. Accelerating the warming of heating floors a) For heating mat laid on a concrete layer
3. Náběhy topných podlah a) uložení na vrstvě betonu
• Wait at least 4–6 weeks after installation before putting the mat into operation, so that the concrete will be set fully.
• On the first day, set the temperature of the floor to be the same as the temperature in the room (maximum 18°C).
• In the following days, increase the temperature in increments of 2°
C per day up to 28°C.
• Maintain the temperature of 28°C for three days.
•
Then, decrease the temperature of the floor by 5°C per day until you reach the initial temperature.
•
Afterwards, you can set the desired temperature and put the floor
• Topná podlaha se uvádí do provozu až po řádném vytvrdnutí betonu po 4–6 týdnech.
• První den nastavit teplotu podlahy shodnou s teplotou v místnosti
(maximálně 18°C).
• Následující dny zvyšovat teplotu podlahy postupně o 2°C/den až na 28°C.
• Teplotu podlahy udržovat na teplotě 28°C po dobu tří dnů.
• Následně snižovat teplotu podlahy o 5°C denně dokud nedosáhne počáteční teploty.
• Poté je možno teplotu podlahy nastavit na požadovanou a uvést podlahu do běžného provozu. into normal operation.
b) For heating mat laid into self-leveling material and into adhesive sealing cement b) uložení v samonivelační hmotě a v lepícím tmelu
• We recommend putting the mat into operation after 5 days from
• Topnou podlahu doporučujeme uvést do provozu po 5 dnech od laying the final layer of the floor (floor covering).
Note: The values mentioned above are for information only, it is necessary to follow the instructions provided by the manufacturer of the respective construction material. položení finální vrstvy podlahy (krytiny).
Pozn.: Uvedené údaje jsou doporučené, přednostně je nutno se řídit pokyny uvedenými výrobcem příslušné stavební hmoty.
7
4. Warranty, claims 4. Záruka, reklamace
ECOFLOOR, supplier of the cable circuits, provides a warranty period Dodavatel kabelových okruhů ECOFLOOR poskytuje záruku na její of 10 years for the product’s functionality, beginning from the date of
(installation must be made at latest within 6 months from the date of funkčnost po dobu 10 let ode dne instalace potvrzené na záručním its installation that is confirmed in the certificate of warranty listě (instalace musí být provedena maximálně 6 měsíců od data prodeje) pokud je: purchase), provided that:
• a certificate of warranty and proof of purchase are submitted,
• the procedure described in this user guide has been followed,
• data on laying and connecting the cable in the floor and the resulting measured values of the insulation resistance of the heating
• doložen záruční list a doklad o zakoupení,
• dodržen postup dle tohoto návodu,
• doloženy údaje o skladbě kabelu v podlaze, zapojení a výsledcích měření izolačního odporu topného kabelu,
• dodržen návod výrobce pro aplikaci tmelů. cable are provided, and
• the procedure for applying the sealing cement specified by its producer has been followed.
Claims may be made in writing at the company that performed the installation, or directly to the manufacturer.
The claims procedure: http://www.fenixgroup.eu
Reklamace se uplatňuje písemně u firmy, která provedla instalaci, připadně přímo u výrobce.
Reklamační řád: http://www.fenixgroup.eu
8
Fenix s.r.o.
Jaroslava Ježka 1338/18a, 790 01 Jeseník tel.: +420 584 495 442, fax: +420 584 495 431 e-mail: [email protected] , http://www.fenixgroup.cz
Fenix Trading s.r.o.
Slezská 2, 790 01 Jeseník tel.: +420 584 495 304, fax: +420 584 495 303 e-mail: [email protected] , http://www.fenixgroup.cz
advertisement
Key Features
- Heating cable attached to fiberglass fabric
- IP67 protection
- Flexible adhesive sealing cement compatible
- Suitable for bathrooms and kitchens
- Comes with fastening strips and adhesive tapes
- 10 years warranty