Alpha 1000W - 1500W AC-DC power supply Datasheet - TDK
• Up to 16 outputs
• Voltages up to 48V, Current up to 300A
• Fast-on output connection
• Worldwide approvals & CB report
• Medical Approval Option
• 3 Year Warranty
Key Market Segments & Applications
Instrumentation
Broadcast
Medical
ATE
Automation
Industrial Computing
Security
Lifesciences/Laboratory
Network Servers and Routers
Alpha Series
1000 and 1500W
AC/DC Modular
Features and Benefits
Features
Benefits
• Low Profile
• Fast-on output terminal
• Medical Approval available
• Simpler to install in system
• Reduces installation time/errors
• Suitable in medical applications
INPUT
Alpha 1000
85 - 264Vac, 120 - 360Vdc
Alpha 1500
85 - 264Vac (1000W below 150Vac input)
47 - 63Hz (440Hz with reduced PFC - consult factory)
<50A at 25°C and 264Vac (cold start)
20A / 250Vac HBC Fast Acting (not user accessible)
1.1mA max at 264Vac & 63Hz
see configuring guide
0.99 typical
Input Voltage
Input Frequency
Inrush Current
Input Fuse
Leakage Current
Lower Leakage Option
Power Factor
OUTPUT
Voltage / Current
Turn on Delay
Rise Time
Turn on Overshoot
Efficiency
See module output table
1.5s max
<50ms
at 90Vac (150Vac for Alpha 1500W) & 100% rated output power
to 90% of voltage, monotonic rise above 10%
<5% or 250mV Load type dependant, no overshoot with resistive load
Ripple & Noise
<2%
typical at 230Vac & 100% rated power, config dependent
at 90Vac & 100% rated output power
13ms for 1000W, 8ms for 1500W and at 207Vac for 1500W
(or 100mV if greater) Pk- Pk, using EIAJ test method & 20MHz bandwidth
Voltage Accuracy
<1%
of set Voltage
Hold up
Remote Sense
Minimum Load
Temperature Coefficient
Load Regulation
75%
13ms min Yes
No
<0.02%
Standard on single output modules
on any output
of rated voltage per °C
<0.5% or 25mV for 0-100% load change (with sense connected, <2% without)
Line Regulation
<0.5%
for 90 - 264Vac input change (210-264Vac for 1500W)
Cross Regulation
<0.2%
for 100% load change on any other output
<10%
of set voltage for 50% load change (above 25% load)
Transient Response Recovery
Over Voltage Protection
Over Current Protection
500µs
Standard
Standard
Short Circuit Protection
<150%
Over Temperature Protection
Yes
for recovery to 1% or 100mV of set voltage (1000µs for S module)
for all outputs
for all outputs
of rated current, when output voltage <1%
Shuts down all outputs. Cycle ac off / on to reset
Note shutdown temp varies according to ambient, output power and input V
Alpha Series
1
SAFETY APPROVALS
Date
EN 60950-1
2001
UL 60950-1
CSA22.2 No 60950-1
IEC60950-1*
Amendments
Date
IEC 60601-1a
1988
2003
UL 60601-1a
2003
2003
CSA 60601-1a
2003
2001
CE Mark
* CB Certificate and report available on request
Amendments
A1, A2
LV Directive 2006/95/EC (EN60950-1)
a - Only for LL, RL and TL leakage variants. CA400 + CA1000 only
PRODUCT, GENERIC & COLLATERAL STANDARDS
Low Voltage Power Supply, EMC
EN61204-3: 2001
Compliant to High
Severity Immunity
Compliant
Medical Electrical Equipment, EMC
EN61601-1-2: 2001
Immunity for residential, commercial and light
EN61000-6-1: 2001
industrial environments
Immunity for industrial environments
EN61000-6-2: 2001
Compliant
Emissions for industrial environments
Compliant
EN61000-6-4: 2001
Class A emissions for CA1000 / CA1500
Class A emissions for CA1000 / CA1500
Compliant
EMISSIONS
Radiated Electric Field
EN55022
Class A (as per CISPR.22)
Conducted Emissions
EN55022
Class A (as per CISPR.22)
Conducted Harmonics
EN61000-3-2: 2001
Compliant to Class A
Flicker
EN61000-3-3: 1995 + A1:2001
Compliant - dmax only.
See application note for details.
Only for ‘S’ type leakage versions
Only for ‘S’ type leakage versions.
Criteria
IMMUNITY
Electrostatic Discharge
EN61000-4-2
Level 4
Electromagnetic Field
EN61000-4-3
Level 3
Fast / Burst Transient
EN61000-4-4
Level 4
Surge Immunity
EN61000-4-5
Level 3
Conducted RF Immunity
EN61000-4-6
Power Frequency Magnetic Field
EN61000-4-8
Level 3
10V (tested to 12V)
A
Level 4
30A Continuous
A
A
Voltage Fluctuations
Class 3
For 100 to 240V nominal
A
A
0°C to 70°C operational, -40° to 70°C storage (max 12 months)
50°C to 70°C derate each output by 2.5% per °C
Low Temperature Start-up
-20°C
Humidity
5-95% RH non condensing
Shock
3000 shocks, each of 10g (16ms) half sine
Vibration
10 - 200Hz @ 1.5g
Altitude
3,000 metres operational (15,000 metres non operational)
Pollution
Degree 2, Material group 3
IP Rating
IP 10
2
A
B for 5s interruptions
Derating
ISOLATION
Input to Output
Input to Earth
A
A
Class 3
ENVIRONMENT
Temperature
15kV
8kV
10V/m (tested to 12V/m)
Input
4kV
Outputs
2kV,
Tested at 5kHz and 100kHz
Line to Line
(Differential)
1.1kV
Line to Earth (Common Mode) 2.2kV
Voltage Dips, Variation, Interruptions EN61000-4-11
EN61000-4-14
Air discharge
Contact discharge
Reinforced
Basic
4.3 kV (dc)
2.3 kV (dc)
Output to Earth
Output to Output
Alpha Series
Operational
Operational
500 V (dc)
500 V (dc)
OUTPUT VOLTAGES (single output modules)
Adjustment
Amps
Slots
Module Range (Volts)
Module
V1 Adjustment
Range (Volts)
(twin output modules)
V2 Adjustment
Amps
Range (Volts)
Amps
Slots
1
A
4.5
-
5.5
60
2
E
5
-
16
8
5
-
16
8
AA
4.5
-
6.2
60
2
EB
4.5
-
5.5
9
4.5
-
5.5
9
1
B
4.5
-
5.5
25
1
EQ
4.5
-
5.5
9
2.7
-
3.9
9
1
BB
4.5
-
6.5
25
1
H
18
-
32
5c
18
-
32
5c
1
C
5
-
16
16a
1
P
18
-
29
5
5
-
16
8
1
D
18
-
29
8
1
F
9
-
15.5
33
2
G
17.5
-
29
25
2
J
30
-
48
10b
2
K
18
-
29
15
2
L
1.8
-
3.2
25
1
M
5
-
16
8
1
1
N
18
-
32
5c
Q
2.7
-
3.9
25
1
R
2.7
-
3.9
60
2
S
2.5
-
5.7
85
2
T
1.8
-
3.2
60
2
U
10
-
21
16
1
W
4.5
-
5.5
15
1
Z
4.5
-
5.5
25
1
a) 12A max above 12V
b) Derate output current by 0.25A / V above 40V
c) 1A max above 29V
Alpha Configuring Guide
The extensive range of output modules and options make it possible to achieve many combinations of Volts and Amps. To achieve the optimum configuration, please contact our sales office. However you can also create your own configuration from this datasheet by using the
guide below.
Configuring from Datasheet
1 Calculate total output power to determine Alpha 1000W or 1500W and select converter, then select required Cooling and Leakage Current
from the following table:-
CA
Output
Power
1000
1500
1000
(7 slots)
(8 slots)
LL
Earth Leakage
Current
(at 264Vac, 63Hz)
empty
ML
LL
RL
TL
Standard 1.1 mA
500µA
240µA
110µA
50µA
Notes:
a) Contact sales office for details
2 Select Output Modules and Options from the Output Voltages tables.
Example - if you require 5.2V / 18A with output inhibit : a) select B as closest match for voltage and current and prefix with voltage (e.g. 5.2B)
b) add suffix for option (if required)
‘_PA’ for parallel/current share (for N+1 redundant applications)
‘_PP’ for parallel (increase current from one PSU)
‘_IN’ for inhibit
‘_RP’ for remote programming
‘_MF’ (only applicable on 1st module) for global inhibit, ac fail and 5V/50mA standby supply
c) repeat for other outputs
Ensure that the total width of all selected modules is within the slots for the chosen converter. For example:CA1000 5A 12/12E 24G which represents a four output 1000W Alpha with Forward air, 1.1mA Earth Leakage, with:Output 1 = 5V / 60A with remote sense
Output 2 = 12V / 8A
Output 3 = 12V / 8A
Output 4 = 24V / 25A with remote sense
3 Contact TDK-Lambda to validate configuration and issue a part number.
Alpha Series
3
Option Connections
4
1
5
2
6
3
IN, PA,
PP, RP
Option
1 slot, 2 output
1 slot, 1 output
2 slot, 1 output
+
+
-
-
+
Pin IN option
PA option PP option RP option MF option
1
n/c
+ Sense
+ Sense + Sense Inhibit (low)
2 Module Good Module Good
n/c
- Sense 5V supply
3
Inhibit
Star point
n/c
Control 2 Power Fail
4
n/c
- Sense
- Sense
n/c
0V
5
- Power
- Power
n/c
Control 1 Inhibit (high)
6
- Power
Star point
n/c
n/c
n/c
Alpha 1000
Alpha 1500
4
Alpha Series
+
-
+
-
+
-
Remote sense
MF option
-
6
5
4
3
2
1
TDK-LAMBDA EMEA
www.emea-tdk-lambda.com
TDK-Lambda France SAS
TDK-Lambda UK Ltd.
Route de Grivery
ZAC des Delaches
CS 41077
91978 Courtaboeuf Cedex
France
Tel: +33 1 60 12 71 65
Fax: +33 1 60 12 71 66
[email protected]
www.fr.tdk-lambda.com
Kingsley Avenue
Ilfracombe
Devon EX34 8ES
United Kingdom
Tel: +44 (0) 12 71 85 66 66
Fax: +44 (0) 12 71 86 48 94
[email protected]
www.uk.tdk-lambda.com
Italy Sales Office
Nemic Lambda Ltd.
TDK-Lambda Germany GmbH
Russia
Kibbutz
Givat Hashlosha 48800
Israel
Tel: +9 723 902 4333
Fax: +9 723 902 4777
[email protected]
www.nemic.co.il
Via dei Lavoratori 128/130
20092 Cinisello Balsamo (MI)
Italy
Tel: +39 02 61 29 38 63
Fax: +39 02 61 29 09 00
[email protected]
www.it.tdk-lambda.com
Karl-Bold-Strasse 40
77855 Achern
Germany
Tel: +49 7841 666 0
Fax: +49 7841 5000
[email protected]
www.de.tdk-lambda.com
Technical Support:
St Petersburg
Tel: +7 (812) 6580463
Sales:
Moscow
Tel: +7 (499) 7557732
[email protected]
www.tdk-lambda.ru
Austria Sales Office
Aredstrasse 22
2544 Leobersdorf
Austria
Tel: +43 2256 655 84
Fax: +43 2256 645 12
[email protected]
www.de.tdk-lambda.com
LOCAL DISTRIBUTION
Document number 60887 - Rev 7.1 - June 2011
5
Alpha Series