Altronix eBridge 8PCRM, 16PCRM, 1PCTX IP and PoE+ over Coax Solution Installation Guide
Below you will find brief information for IP and PoE+ over Coax Solution eBridge 8PCRM, IP and PoE+ over Coax Solution eBridge 16PCRM. These devices allow you to transmit data and power over existing coax cabling, enabling the upgrade of analog CCTV systems to IP cameras or other PoE-enabled devices. The eBridge8PCRM/16PCRM receivers are powered by PoE midspans or endspans and deliver PoE+ power to the eBridge1PCTX transmitters, which then power the IP cameras. This solution is ideal for retrofitting digital IP cameras in existing analog CCTV installations, extending network link distances, and upgrading deployed CCTV coax to a digital network.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
IP and PoE+ over Coax Solution
PLUS
Installation Guide
Models Include:
eBridge8PCRM
- Eight (8) Channel Receiver
eBridge16PCRM
- Sixteen (16) Channel Receiver
I.T.E. 43KC
Rev. 072412
Z1409
More than just power.™
Overview:
The eBridge8PCRM/16PCRM and eBridge1PCTX are CAT5 to Coax cable Ethernet adapters/Media converters that deliver data and power over the coax cable in a PoE+ compliant format. The paired set enables fast 10/100Base-T Ethernet digital communication to be transmitted over Coax cable. An eBridge8PCRM/16PCRM receiver is powered by a UL Listed limited power source, PoE midspan or endspan product, such as a NetWay8M and NetWay16M, and sends its power over the coax to the eBridge1PCTX transmitter under PoE protocol. This enables the eBridge8PCRM/16PCRM to be used in a managed manner, allowing for remote camera reset. The eBridge1PCTX in turn delivers that PoE+ compliant power to a PoE enabled camera or IP device. The eBridge8PCRM/16PCRM will not deliver power to non-compliant devices, thus avoiding damage to improperly connected analog cameras. These plug and play units facilitate system upgrades from analog to IP cameras/ devices utilizing existing legacy Coax and eliminating the costs and labor associated with installing new network cabling.
In addition, data transmission and power over the Coax is possible up to 457m in comparison to 100m Ethernet maximum distance (see Maximum Length of Coax Type vs. Camera Power/PoE Class, pg. 3). A maximum range from head end to the PoE camera/device is 657m taking into consideration that up to 100m of structured cable may be deployed at each end.
Features:
LED Indicators (cont’d):
• eBridge1PCTX:
Blue LED - Coax link connection.
Green LED - PoE from eBridge8PCRM/16PCRM.
Agency Listings:
• UL/CUL Listed for Information
Technology Equipment (UL 60950-1).
• CE approved.
• C-Tick compliant.
Input:
• Powered by a UL Listed limited power source,
PoE midspan or endspan.
Ethernet:
• Connectivity: RJ45, auto-crossover.
• Wire type: 4-pair CAT5 or better structured cable.
• Distance: up to 100m.
• Speed: 10/100BaseT, half/full duplex, auto negotiation.
PoE compliant to IEEE 802.3af (15W) and PoE+
compliant to IEEE 802.3at (30W) Delivered to camera by
eBridge1PCTX. Power provided by eBridge8PCRM/
16PCRM to eBridge1PCTX by PoE protocol.
• Throughput is rated to pass 25mbps of data at
distances up to 457m. With proper headend
equipment, this supports Megapixel, HD720, HD1080.
Coax:
• Distance: up to 457m (see Maximum Length of Coax
Type vs. Camera Power/PoE Class, pg. 3) for power
delivery of coax.
• Connectivity: BNC, RG-59/U or similar.
LED Indicators:
• eBridge8PCRM (16PCRM):
Blue LED - Coax link connection.
Green - PoE ON.
Green - Power ON.
• eBridge8PCRM/16PCRM and eBridge1PCTX:
Yellow and Green LED (RJ45) IP Link status,
10/100Base-T/active.
Environmental:
• Operating Temperature: eBridge8PCRM/16PCRM:
-- 4ºF to 120.2ºF (-- 20ºC to +49ºC).
eBridge1PCTX: --- 4ºF to 120.2ºF (-- 20ºC to +49ºC).
• Storage Temperature:
-- 22º to 158ºF (-- 30º to +70ºC) Storage.
• Humidity: 20 to 85%, non-condensing.
Functions:
• Auto detection and protection of legacy
non-PoE cameras/devices.
Applications:
• Retrofit digital IP cameras in an analog CCTV
installation.
• Works with Megapixel, HD720, HD1080 and VGA
(SD) cameras (see note, pg. 2).
• Extend Network link distance in an industrial
environment over 610m (see note, pg. 2).
• Upgrade deployed CCTV Coax to a digital network
in Retail, Hospitality, Arenas, Casinos, Airports,
Schools, Hospitals, Transportation, etc.
Mechanical:
• Dimensions (H x W x D approx.):
eBridge8PCRM/16PCRM:
1.625” x 19.125” x 8.5” (42mm x 486mm x 216mm)
eBridge1PCTX:
1” x 2.5” x 4.375” (25.4mm x 63.5mm x 111.125mm)
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Wiring should be UL Listed and/or Recognized wire suitable for the application.
eBridge8PCRM/16PCRM is not intended to be connected to outside plant leads and should be installed indoors within the protected premises. The eBridge8PCRM/16PCRM and eBridge1PCTX are intended for indoor use only.
Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Do not obstruct any air vents on the unit. It is recommended to leave half space above and below the unit.
- 2 - eBridge8PCRM/16PCRM
Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.
Circuit Overloading - Consideration should be given to the connection of the equipment to supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate rating should be used when addressing this concern.
Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips).
1. eBridge8PCRM/16PCRM installation:
a. Attach mounting brackets to eBridge8PCRM/16PCRM unit for rack installation (Fig. 4, pg. 6).
Affix rubber pads to eBridge8PCRM/16PCRM for shelf installation (Fig. 5, pg. 6).
Unit should be located in proximity to ethernet switch/network, NVR or video server.
b. Connect structured cable from ethernet midspan or endspan device to RJ45 jack marked [10/100BaseT]
(Fig. 2, pg. 3).
c. Connect Coax cable to BNC connector marked [Coax] (Fig. 1, pg. 3).
2. eBridge1PCTX installation:
a. Secure unit to desired mounting surface with a proper fastening device utilizing the case’s mounting hole.
Unit should be mounted in proximity of camera/device.
b. Connect structured cable from IP camera/device to RJ45 jack marked [10/100BaseT] (Fig. 2, pg. 3).
c. Connect Coax cable to BNC connector marked [Coax] (Fig. 2, pg. 3).
Note: The eBridge8PCRM/16PCRM is designed to accommodate Megapixel, HD720, HD1080 and VGA (SD) cameras.
It is important to note that some high resolution and high frame rate cameras may demand faster headend processing ability, such as a PC graphics card to present a quality image. If the headend processing equipment is insufficient in speed, the image may show pixelation and latency. It is advisable to pretest system if unsure. Alternatively, frame rate and resolution may be reduced to accommodate system equipment.
Fig. 1
eBridge8PCRM
Coax
Cable from eBridge1PCT or eBridge1PCTX
8 7
Data In
6 5 4 3
Data In
2 1
eBridge8PCRM (rear)
Fig. 1a
1
eBridge8PCRM (front)
2 3 4
Coax
Cable from eBridge1PCT or eBridge1PCTX
10/100
Base-T
10/100
Base-T
5 6 7
Structured
Cable from midspan/endspan
8
eBridge16PCRM
16 15
eBridge16PCRM (rear)
Data In
14 13 12 11
Data In
10 9 8 7
Data In
6 5 4 3
Data In
2 1
1
eBridge16PCRM (front)
2 3 4
10/100
Base-T
5 6 7
Structured
Cable from midspan/endspan
8
10/100
Base-T
9 10 11 12
10/100
Base-T
13 14 15 16 eBridge8PCRM/16PCRM - 3 -
Fig. 2 eBridge1PCTX
Fig. 3
Green LED indicates
Power
Structured
Cable from
IP Camera/Device
Coax
Cable from eBridge8PCRM/16PCRM
Blue LED indicates
Coax Connection
Multiple PoE camera connection:
eBridge8PCRM shown. eBridge16PCRM is similar, with twice as many channels.
Ethernet Switch eBridge8PCRM
PoC (PoE+ over Coax)
457m max.
PoC (PoE+ over Coax)
457m max.
PoC (PoE+ over Coax)
457m max.
PoC (PoE+ over Coax)
457m max.
eBridge1PCTX PoE compliant
100m max.
PoE Camera eBridge1PCTX
PoE compliant
100m max.
PoE Camera eBridge1PCTX
PoE compliant
100m) max.
PoE Camera eBridge1PCTX
PoE compliant
100m max.
PoE Camera
NetWay8M - Front Panel
+ PoE --
SHUTDOWN
Local Area Network (LAN) or Laptop connection
PoC (PoE+ over Coax)
457m max.
PoC (PoE+ over Coax)
457m max.
PoC (PoE+ over Coax)
457m max.
PoC (PoE+ over Coax)
457m max.
eBridge1PCTX eBridge1PCTX PoE compliant
100m max.
PoE Camera eBridge1PCTX
PoE compliant
100m max.
PoE Camera eBridge1PCTX
PoE compliant
100m max.
PoE Camera eBridge1PCTX
PoE compliant
100m max.
PoE Camera
Legend:
Coax
Structured Cable
- 4 - eBridge8PCRM/16PCRM
Parameter
Connections
Input power requirements
Indicators
Environmental
Conditions
Regulatory
Compliance
Technical Specifications:
Description
BNC for Coax link. RJ45 for ethernet link.
Midspan or endspan port connected.
Blue: Coax Link.
Yellow (RJ45 connector): On - Link, Off - No Link, Blinking - Activity.
Green (RJ45 connector): On - 100Base-TX, Off - 10Base-T.
Green: Power.
Operating Ambient Temperature: UL60950-1
eBridge8PCRM/16PCRM: -- 4ºF to 120.2ºF (-- 20ºC to +49ºC).
eBridge1PCTX: --- 4ºF to 120.2ºF (-- 20ºC to +49ºC).
Relative humidity: 20 to 85%, non-condensing.
Storage Temperature: -- 22º to 158ºF (-- 30º to +70ºC) Storage.
Operating Altitude: -- 1000 to 6,561.679 ft. (-- 304.8 to 2000m).
UL/CUL Listed for Information Technology Equipment (UL 60950-1).
CE approved. C-Tick compliant.
Camera
Power/
PoE Class
13W/0
4W/1
6.5W/2
13W/3
19W
25W
Maximum Length of Coax Type vs. Camera Power/PoE Class:
RG59/U
(23AWG)
260.64m
457.20m+
457.20m+
260.64m
260.64m
260.64m
RG59/U
(22AWG)
335.28m
457.20m+
457.20m+
335.28m
335.28m
335.28m
RG59/U
(20AWG)
Max. Length (meters)
457.20m+
457.20m+
457.20m+
457.20m+
457.20m+
457.20m+
RG59/U
(18AWG)
457.20m+
457.20m+
457.20m+
457.20m+
457.20m+
457.20m+
RG6/U
(18AWG)
457.20m+
457.20m+
457.20m+
457.20m+
457.20m+
457.20m+ eBridge8PCRM/16PCRM - 5 -
Mounting Options:
Rack Mount Installation
1- Remove and discard factory installed screws from both sides of rack chassis (Fig. 4a).
2- Install mounting brackets (A) on the left and right side of rack chassis using the
four (4) flat head screws (B) (included) (Fig. 4b).
3- Place unit into desired EIA 19” rack position and secure with mounting screws (not included) (Fig. 4c).
Fig. 4
Fig. 4a Fig. 4b Fig. 4c
Top
Top Top
Front
Left
Front
Left
Front Left
B
Remove
A
Shelf Installation
1- Position and affix rubber pads (C) (included) at each
corner on the bottom of the unit (Fig. 5).
2- Place unit in desired location.
Fig. 5
Left Side
Mounting Hardware
(Included):
A Two (2) mounting brackets
B
Six (6) flat head screws for mounting brackets.
C Four (4) rubber pads.
C
Rubber Pad
- 6 - eBridge8PCRM/16PCRM
8.5"
216mm
Enclosure Dimensions
(H x W x D approximate)
:
1.625” x 19.125” x 8.5” (42mm x 486mm x 216mm) eBridge16PCRM shown. eBridge8PCRM is similar.
0.75"
19.05mm
1 2 3 4
10/100
Base-T
5 6 7 8
10/100
Base-T
19.125"
486mm
17.625"
447.7mm
9 10 11 12
10/100
Base-T
13 14 15 16
10/100
Base-T
1.625"
42mm
16 15
Data In
14 13 12 11
Data In
10 9 8 7
Data In
6 5 4 3
Data In
2 1 eBridge8PCRM/16PCRM - 7 -
Notes:
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 website: www.altronix.com, e-mail: [email protected], Lifetime Warranty, Made in U.S.A.
IIeBridge8PCRM/16PCRM
- 8 -
G25N MEMBER eBridge8PCRM/16PCRM
advertisement
Key Features
- Data and power over coax
- PoE+ compliant
- Up to 457m transmission distance
- Retrofit analog CCTV to IP
- Extend network link distance
- Upgrade CCTV coax to digital network
- Auto detection and protection of legacy cameras
- Supports Megapixel, HD720, HD1080 cameras
- Plug and play installation