MK 1149WHI SG Type Installation Manual

MK 1149WHI SG Type Installation Manual

Below you will find brief information for Lampholder 1140 WHI, Lampholder 1141 WHI, Lampholder 1142 WHI, Lampholder 1143 WHI, Lampholder 1144 WHI, Pendant Set 1156 WHI, Pendant Set 1157 WHI, Pendant Set 1158 WHI, Pendant Set 1159 WHI. This Shock Guard Lampholder is designed to minimize installation time while offering maximum safety to the installer and greatly enhanced safety to the user. The Shock Guard (SG) system ensures that the lampholder contact pins are not live when a bulb is removed.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

MK Lampholder 1140 WHI, 1141 WHI, 1142 WHI, 1143 WHI, 1144 WHI - Instructions | Manualzz
A
Ceiling Accessories
Shock Guard Lampholders
1140 WHI, 1141 WHI, 1142 WHI, 1143 WHI, 1144 WHI
1156 WHI, 1157 WHI, 1158 WHI, 1159 WHI
CONTENTS Pa
e
©
Introduction
© | 2 | 5
Product Range
Safety Instructions
Installation Instructions - Pendant Lampholders
Straight, Batten Lampholder
Angled Batten Lampholder
Disposal Instructions
Guarantee
Г | = | — |
«| Sl o | PS |“ | A IS
| A. INTRODUCTION
| B. PRODUCT RANGE |
This range of SG type lampholders has been
carefully designed to minimise installation time,
whilst offering maximum safety to the installer
and greatly enhanced safety to the user.
The Shock Guard (SG) system ensures that the
lampholder contact pins are not live when a
bulb is removed.
If you are in any doubt regarding the
application or installation of this product,
please contact the MK Technical Sales Service
Department on 081-803 3355 or your local
MK representative.
Please leave this leaflet with the consumer for future reference L
C. SAFETY INSTRUCTIONS
|
Ensure the mains supply is switched off before
installation or maintenance of this product.
This product should be installed by a competent
person (e.g. a qualified electrician) in accordance
with these instructions and in accordance with
the appropriate clauses of the current edition of
the wiring regulations (BS 7671).
Health and Safety at Work Act 1974.
Users of this product are requested to take note
of the above act and are advised that a full
statement is contained within the MK catalogue.
To ensure that the cable clamp will grip
sufficiently, use only two core circular cable as
specified in the installation instructions.
2
Сар
(operates
cord grip)
Cover
Clip
Fig 1. Pendant Lampholder
(shown with shade ring removed)
6
11. Assemble the lamp shade onto the
lampholder and hold it in place with the
shade ring.
NB If the lampholder ever has to be
disconnected, switch off the electricity
supply at the mains and unscrew the cap
to release the cable prior to unclipping the
cover from the lampholder.
For Pendant and Angled Batten Holders
| 15mm
5mm
RED or BROWN |=—""%1
For Straight Batten Holders
amm, |
BLACK Sa
Fig 2. Supply Cable Preparation
4 nN
1140 WHI - BC pendant SG Lampholder
1141 WHI - BC pendant SG Lampholder and
protective shield.
1142 WHI - BC angled SG batten Lampholder
with loop-in terminal.
1143 WHI - SG batten Lampholder, 2 terminals
with loop-in and earth terminals mounted in
the base.
1144 WHI - SG batten Lampholder, H.R. tails,
live, neutral, loop-in and earth terminals
mounted in the base.
1156 WHI - 6 inch SG type pendant set.
1159 WHI - 9 inch SG type pendant set.
Ceiling Rose Instruction Leaflet No. 19735PL
covering the two above products is available
from the address given at the end of this leaflet
1157 WHI - 6 inch SG type pendant set with
PiL Ceiling Rose.
1158 WHI - 9 inch SG type pendant set with
PiL Ceiling Rose.
Plug-in Lighting (PiL) Instruction Leaflet No.
17921 covering these products is available
from the address given at the end of this
leaflet.
3
D. INSTALLATION INSTRUCTIONS
PENDANT LAMPHOLDERS
1. Switch off the electricity supply at the
mains.
2. Remove the shade ring from the
lampholder.
3. Insert a screwdriver carefully under each
of the two white clips holding the white
cover to the grey lampholder body. Lever
4. Unscrew the cap of the white cover as far
as it can go. (N.B. When unscrewed, the
cap does not separate entirely).
clips slightly upwards to remove the cover.
5. Use heat resisting PVC insulated and
sheathed flexible 0.75mm?2 two core
circular cable complying with
BS 4568:Pt:2:1970.
6. Strip cable in accordance with figure 2.
7. Thread the cable through hole in top of
cover/cap.
8. Make the supply cable connections to the
product and tighten terminal screws
securely.
9. Re-clip cover onto lampholder. Ensure the
clips are fully engaged.
10. Firmly screw the cap down. This will ensur
cable is adequately gripped in the clamp.
7
8
Fig 3. Straight, Batten Lampholder
(shown with shade ring removed)
STRAIGHT, BATTEN LAMPHOLDER
1. Switch off the electricity supply at the main:
2. Remove the shade ring from the
lampholder.
Unscrew the rose cover.
4. Pull lampholder from seating in the rose
base.
5. Ensure the base is level and fix securely tc
the ceiling using two countersunk No. 8
wood screws into a joist as shown in
figure 4.
6. Strip cable in accordance with figure 2.
Continued overleai
+44
INSTALLATION INSTRUCTIONS CONT. |
7. Make supply cable connections to the
product as shown in figures 5a or 5b, as
required, and tighten terminal screws
securely.
8. Push lampholder back onto the rose base
and replace the rose cover.
9. Assemble lamp shade onto the lampholder
(if required) and replace the shade ring.
Plasterboard Joist
yer heel
a
1227774
|
|
|
| |
Fig 4. Straight, Batten Holder Fixing
TRE RED
XOE GREEN/YELLOW
BLACK
1apjoyduie]
wo SIE |
—.Red Sleeving
Fig 5a
== RED
SÓ GREEN/YELLOW
BLACK
—
ЕЕ
=
=
5 =
== a
Si ©
= o
E: =
æ3
æ
LINE
- To Switch
or to tog
Junction Box
14
15
Fig 6. Angled, Batten Lampholder
(shown with shade ring removed)
ANGLED, BATTEN LAMPHOLDER
Switch off the electricity supply at the mains.
Remove the shade ring from the lamphoider.
Unscrew the clamping ring. (See figure 6)
The grey lampholder moulding is then free
to be withdrawn through the rear of the
angled mounting.
Position angled mounting where required,
ensure the base is level and mark the
fixing screw positions.
If wall mounting, beware of hidden wiring
or pipes prior to drilling and plugging the
wall to take the No. 8 fixing screws.
6. Ensure the cable ends are stripped in a
similar manner to those shown in figure 2.
7. Insert the cable into the two terminals and
tighten the terminal screws securely.
8. Replace angled mounting over the lamp-
holder. Orientate and pull forward the
lampholder until correctly seated in the
mounting, then hold in place with the
clamping ring.
9. Fix the Batten lampholder in place using
No.8 screws.
10. Assemble lamp shade onto the lampholder
(if required) and replace the shade ring
| E. DISPOSAL INSTRUCTIONS
Product and packaging can safely be disposed
of via standard refuse facilities at the end of its
useful life.
The end user should keep these instructions
for future reference.
17
18
19
20
F. GUARANTEE
MK are prepared to make good, by repair or
at MK's option by the supply of a
replacement, defects which, under proper
use, appear in the Goods within a period of
ten years after the Goods have been
delivered (within two years for mains related
electronic products) and arise solely from
faulty materials or workmanship, provided
that no attempt has been made by the
customer to rectify, dismantle, or alter the
products in any way.
MK is not liable for any loss or damage
(other than death, or personal injury) arising
or said to arise from MK’s-negligence from
the use of any of MK's goods unless the
goods were not manufactured in accordance
with the relevant legislation and Codes of
Practice in force at the time of manufacture,
and the said loss or damage arises within
ten years of delivery. Consumers have rights
under the law against sellers if the product is
defective or unsatisfactory. This Guarantee
does not and will not affect your statutory
rights.
MK Electric wishes to make it clear that it
owns all the original designs of the products
which it manufactures (whether or not listed
in this leaflet) and that it will take all
necessary legal action in any part of the
world against any party found to be
manufacturing, distributing, selling or
otherwise dealing with any article which
infringes the companies copyrights or
patents in its products, or any other right of
the company therein.
Caradon MK Electric Limited
Shrubbery Road, Edmonton,
London N9 OPB
Tel: 081-803 3355
Telex: 22422 MK UK G
(UK Sales)
299464 MK INT G
(International)
081-807 5733
(UK Sales)
081-803 8410
(International)
40842PL Ed.1

advertisement

Key Features

  • Shock Guard System
  • Easy Installation
  • Safe for Installer
  • Safe for User
  • Minimizes Installation Time
  • Improved Safety

Frequently Answers and Questions

How do I install the Lampholder?
Switch off the electricity supply at the mains and follow the instructions in the document.
What types of cables can I use with the Lampholder?
Use heat resisting PVC insulated and sheathed flexible 0.75mm?2 two core circular cable complying with BS 4568:Pt:2:1970.
Is there a guarantee for the Lampholder?
MK is prepared to make good, by repair or at MK's option by the supply of a replacement, defects which, under proper use, appear in the Goods within a period of ten years after the Goods have been delivered (within two years for mains related electronic products) and arise solely from faulty materials or workmanship, provided that no attempt has been made by the customer to rectify, dismantle, or alter the products in any way.
What is the purpose of the Shock Guard system?
The Shock Guard (SG) system ensures that the lampholder contact pins are not live when a bulb is removed.