- MK
- 1149WHI
- Installation manual
- 2 Pages
MK 1149WHI SG Type Installation Manual
Below you will find brief information for Lampholder 1140 WHI, Lampholder 1141 WHI, Lampholder 1142 WHI, Lampholder 1143 WHI, Lampholder 1144 WHI, Pendant Set 1156 WHI, Pendant Set 1157 WHI, Pendant Set 1158 WHI, Pendant Set 1159 WHI. This Shock Guard Lampholder is designed to minimize installation time while offering maximum safety to the installer and greatly enhanced safety to the user. The Shock Guard (SG) system ensures that the lampholder contact pins are not live when a bulb is removed.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
A Ceiling Accessories Shock Guard Lampholders 1140 WHI, 1141 WHI, 1142 WHI, 1143 WHI, 1144 WHI 1156 WHI, 1157 WHI, 1158 WHI, 1159 WHI CONTENTS Pa e © Introduction © | 2 | 5 Product Range Safety Instructions Installation Instructions - Pendant Lampholders Straight, Batten Lampholder Angled Batten Lampholder Disposal Instructions Guarantee Г | = | — | «| Sl o | PS |“ | A IS | A. INTRODUCTION | B. PRODUCT RANGE | This range of SG type lampholders has been carefully designed to minimise installation time, whilst offering maximum safety to the installer and greatly enhanced safety to the user. The Shock Guard (SG) system ensures that the lampholder contact pins are not live when a bulb is removed. If you are in any doubt regarding the application or installation of this product, please contact the MK Technical Sales Service Department on 081-803 3355 or your local MK representative. Please leave this leaflet with the consumer for future reference L C. SAFETY INSTRUCTIONS | Ensure the mains supply is switched off before installation or maintenance of this product. This product should be installed by a competent person (e.g. a qualified electrician) in accordance with these instructions and in accordance with the appropriate clauses of the current edition of the wiring regulations (BS 7671). Health and Safety at Work Act 1974. Users of this product are requested to take note of the above act and are advised that a full statement is contained within the MK catalogue. To ensure that the cable clamp will grip sufficiently, use only two core circular cable as specified in the installation instructions. 2 Сар (operates cord grip) Cover Clip Fig 1. Pendant Lampholder (shown with shade ring removed) 6 11. Assemble the lamp shade onto the lampholder and hold it in place with the shade ring. NB If the lampholder ever has to be disconnected, switch off the electricity supply at the mains and unscrew the cap to release the cable prior to unclipping the cover from the lampholder. For Pendant and Angled Batten Holders | 15mm 5mm RED or BROWN |=—""%1 For Straight Batten Holders amm, | BLACK Sa Fig 2. Supply Cable Preparation 4 nN 1140 WHI - BC pendant SG Lampholder 1141 WHI - BC pendant SG Lampholder and protective shield. 1142 WHI - BC angled SG batten Lampholder with loop-in terminal. 1143 WHI - SG batten Lampholder, 2 terminals with loop-in and earth terminals mounted in the base. 1144 WHI - SG batten Lampholder, H.R. tails, live, neutral, loop-in and earth terminals mounted in the base. 1156 WHI - 6 inch SG type pendant set. 1159 WHI - 9 inch SG type pendant set. Ceiling Rose Instruction Leaflet No. 19735PL covering the two above products is available from the address given at the end of this leaflet 1157 WHI - 6 inch SG type pendant set with PiL Ceiling Rose. 1158 WHI - 9 inch SG type pendant set with PiL Ceiling Rose. Plug-in Lighting (PiL) Instruction Leaflet No. 17921 covering these products is available from the address given at the end of this leaflet. 3 D. INSTALLATION INSTRUCTIONS PENDANT LAMPHOLDERS 1. Switch off the electricity supply at the mains. 2. Remove the shade ring from the lampholder. 3. Insert a screwdriver carefully under each of the two white clips holding the white cover to the grey lampholder body. Lever 4. Unscrew the cap of the white cover as far as it can go. (N.B. When unscrewed, the cap does not separate entirely). clips slightly upwards to remove the cover. 5. Use heat resisting PVC insulated and sheathed flexible 0.75mm?2 two core circular cable complying with BS 4568:Pt:2:1970. 6. Strip cable in accordance with figure 2. 7. Thread the cable through hole in top of cover/cap. 8. Make the supply cable connections to the product and tighten terminal screws securely. 9. Re-clip cover onto lampholder. Ensure the clips are fully engaged. 10. Firmly screw the cap down. This will ensur cable is adequately gripped in the clamp. 7 8 Fig 3. Straight, Batten Lampholder (shown with shade ring removed) STRAIGHT, BATTEN LAMPHOLDER 1. Switch off the electricity supply at the main: 2. Remove the shade ring from the lampholder. Unscrew the rose cover. 4. Pull lampholder from seating in the rose base. 5. Ensure the base is level and fix securely tc the ceiling using two countersunk No. 8 wood screws into a joist as shown in figure 4. 6. Strip cable in accordance with figure 2. Continued overleai +44 INSTALLATION INSTRUCTIONS CONT. | 7. Make supply cable connections to the product as shown in figures 5a or 5b, as required, and tighten terminal screws securely. 8. Push lampholder back onto the rose base and replace the rose cover. 9. Assemble lamp shade onto the lampholder (if required) and replace the shade ring. Plasterboard Joist yer heel a 1227774 | | | | | Fig 4. Straight, Batten Holder Fixing TRE RED XOE GREEN/YELLOW BLACK 1apjoyduie] wo SIE | —.Red Sleeving Fig 5a == RED SÓ GREEN/YELLOW BLACK — ЕЕ = = 5 = == a Si © = o E: = æ3 æ LINE - To Switch or to tog Junction Box 14 15 Fig 6. Angled, Batten Lampholder (shown with shade ring removed) ANGLED, BATTEN LAMPHOLDER Switch off the electricity supply at the mains. Remove the shade ring from the lamphoider. Unscrew the clamping ring. (See figure 6) The grey lampholder moulding is then free to be withdrawn through the rear of the angled mounting. Position angled mounting where required, ensure the base is level and mark the fixing screw positions. If wall mounting, beware of hidden wiring or pipes prior to drilling and plugging the wall to take the No. 8 fixing screws. 6. Ensure the cable ends are stripped in a similar manner to those shown in figure 2. 7. Insert the cable into the two terminals and tighten the terminal screws securely. 8. Replace angled mounting over the lamp- holder. Orientate and pull forward the lampholder until correctly seated in the mounting, then hold in place with the clamping ring. 9. Fix the Batten lampholder in place using No.8 screws. 10. Assemble lamp shade onto the lampholder (if required) and replace the shade ring | E. DISPOSAL INSTRUCTIONS Product and packaging can safely be disposed of via standard refuse facilities at the end of its useful life. The end user should keep these instructions for future reference. 17 18 19 20 F. GUARANTEE MK are prepared to make good, by repair or at MK's option by the supply of a replacement, defects which, under proper use, appear in the Goods within a period of ten years after the Goods have been delivered (within two years for mains related electronic products) and arise solely from faulty materials or workmanship, provided that no attempt has been made by the customer to rectify, dismantle, or alter the products in any way. MK is not liable for any loss or damage (other than death, or personal injury) arising or said to arise from MK’s-negligence from the use of any of MK's goods unless the goods were not manufactured in accordance with the relevant legislation and Codes of Practice in force at the time of manufacture, and the said loss or damage arises within ten years of delivery. Consumers have rights under the law against sellers if the product is defective or unsatisfactory. This Guarantee does not and will not affect your statutory rights. MK Electric wishes to make it clear that it owns all the original designs of the products which it manufactures (whether or not listed in this leaflet) and that it will take all necessary legal action in any part of the world against any party found to be manufacturing, distributing, selling or otherwise dealing with any article which infringes the companies copyrights or patents in its products, or any other right of the company therein. Caradon MK Electric Limited Shrubbery Road, Edmonton, London N9 OPB Tel: 081-803 3355 Telex: 22422 MK UK G (UK Sales) 299464 MK INT G (International) 081-807 5733 (UK Sales) 081-803 8410 (International) 40842PL Ed.1
advertisement
Key Features
- Shock Guard System
- Easy Installation
- Safe for Installer
- Safe for User
- Minimizes Installation Time
- Improved Safety