Below you will find brief information for gas fireplace REVO V12, gas fireplace REVO S21, gas fireplace REVO H31. The REVO series of gas fireplaces offer a variety of options for both on-wall and in-wall installation and are suitable for both natural gas and propane. These fireplaces are designed for supplemental room heat or as a decorative appliance.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
Installation Manual
Installation and Appliance Setup
INSTALLER: Leave this manual with party responsible for use and operation.
OwNER: Retain this manual for future reference.
NOTICE: DO NOT discard this manual!
REVO-V12
Models:
REVO-S21
REVO-H31
wARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
• DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire department.
• Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
DANGER
This appliance may be installed as an OEM installation in manufactured home (USA only) or mobile home and must be installed in accordance with the manufacturer’s instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s) of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
individuals.
TO TOUCH GLASS.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk
In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter.
See Table of Contents for location of additional Commonwealth of Massachusetts requirements.
Pour demander un exemplaire en français de ce Manuel du propriétaire, visitez www.heatnglo.com/translations.
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15 1
Safety Alert Key:
• DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.
• WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.
• CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
• NOTICE: Used to address practices not related to personal injury.
Table of Contents
Installation Standard Work Checklist . . . . . . . . . . . . . . . . . . . . 3
1 Product Specific and Important Safety Information
A. Appliance Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
B. Glass Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
C. BTU Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . . 4
E. Non-Combustible Materials Specification. . . . . . . . . . . . . . 4
F. Combustible Materials Specification . . . . . . . . . . . . . . . . . 4
G. Electrical Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
H. Requirements for the Commonwealth of Massachusetts . . 5
2 Getting Started
A. Design and Installation Considerations . . . . . . . . . . . . . . . 6
B. Tools and Supplies Needed . . . . . . . . . . . . . . . . . . . . . . . . 6
C. Inspect Appliance and Components . . . . . . . . . . . . . . . . . . 6
D. Installation Methods:On-Wall or In-Wall . . . . . . . . . . . . . . . 7
3 Framing and Clearances
A. Appliance/Decorative Front Dimension Diagrams . . . . . . . 8
B. Clearance to Combustibles . . . . . . . . . . . . . . . . . . . . . . . 12
C. Constructing the Appliance Chase . . . . . . . . . . . . . . . . . . 13
D. Floor Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
E. Clearances (On-Wall and In-Wall) . . . . . . . . . . . . . . . . . . 14
F. Clearances - Venting with an Elbow Directly Off the
Back of Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4 Termination Location and Vent Information
A. Vent Termination Minimum Clearances . . . . . . . . . . . . . . 16
B. Chimney Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
C. Approved Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
D. Use of Elbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
E. Measuring Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
F. Vent Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
5 Vent Clearances and Framing
A. Pipe Clearances to Combustibles . . . . . . . . . . . . . . . . . . 27
B. Wall Penetration Framing/Firestops . . . . . . . . . . . . . . . . . 27
C. Ceiling Firestop/Floor Penetration Framing . . . . . . . . . . . 28
D. Install Attic Insulation Shield . . . . . . . . . . . . . . . . . . . . . . . 28
6 Appliance Preparation
A. Vent Collar Preparation - Sealing the Firestop . . . . . . . . 29
B. Install Appliance Corrugated Template . . . . . . . . . . . . . . . . .
(On-Wall Installation) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
C. Install Appliance Outer Wrap (On-Wall Installation) . . . . 33
D. Install Appliance Into Outer Wrap (On-Wall Installation) . . 35
2
= Contains updated information.
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
7 Venting and Chimneys
A. Assemble Vent Sections. . . . . . . . . . . . . . . . . . . . . . . . . . 36
B. Installing Slip Sections . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
C. Secure the Vent Sections . . . . . . . . . . . . . . . . . . . . . . . . . 37
D. Disassemble Vent Sections . . . . . . . . . . . . . . . . . . . . . . . 38
E. Vertical Termination Requirements . . . . . . . . . . . . . . . . . . 39
F. Horizontal Termination Requirements . . . . . . . . . . . . . . . 41
8 Electrical Information
A. General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
B. Wiring Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
9 Gas Information
A. Fuel Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
B. Gas Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
C. Gas Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . 44
E. Air Shutter Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
10 Finishing (On-Wall Installation)
A. Facing and Finishing - Studio and Frame
Decorative Fronts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
B. Facing and Finishing - Radius Decorative Front
(1 Inch Max. Non-Combustible) . . . . . . . . . . . . . . . . . . . . 48
C. Facing and Finishing - Radius Decorative Front
(4 Inch Maximum Non-Combustible) . . . . . . . . . . . . . . . . . . 50
D. Mantel Projections (All Fronts) . . . . . . . . . . . . . . . . . . . . . 52
E. Mantel Leg and Wall Projections . . . . . . . . . . . . . . . . . . . 53
11 In-Wall Installation
A. Wall and Appliance Preparation . . . . . . . . . . . . . . . . . . . . 54
B. In-Wall - Minimum Combustible Facing Clearances . . . . 58
C. In-Wall - Minimum Non-Combustible Facing Clearances 59
D. In-Wall Mantel and Wall Projections . . . . . . . . . . . . . . . . 60
E. In Wall - Finishing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
12 Appliance Setup
A. Removing Fixed Glass Assembly . . . . . . . . . . . . . . . . . . . 62
B. Remove the Shipping Materials . . . . . . . . . . . . . . . . . . . 62
C. Clean the Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
D. Decorative Fronts/Mesh . . . . . . . . . . . . . . . . . . . . . . . . . . 62
13 Reference Materials
A. Vent Components Diagrams . . . . . . . . . . . . . . . . . . . . . . 63
B. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Installation Standard work Checklist
ATTENTION INSTALLER:
Follow this Standard Work Checklist
This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this installation manual.
Customer:
Lot/Address:
Model (circle one): REVO-V12
REVO-S21
REVO-H31
Date Installed:
Location of Fireplace:
Installer:
Dealer/Distributor Phone #
Serial #:
WARNING! Risk of Fire or Explosion! Failure to install appliance according to these instructions can lead to a re or explosion.
Appliance Install
Veri ed that the area behind appliance is insulated and sealed as required. (Pg. 12)
YES
Required non-combustible board installed.(In-Wall Installation only) (Section 11)
Veri ed clearances to combustibles. (Section 3)
IF NO, WHY?
___________________________
___________________________
___________________________
Required In-Wall Kit installed if back of appliance outer wrap penetrates the sheetrock/ nish wall material (In-Wall Installation only) ___________________________
Verified appliance is installed a minimum of 4 inches above finished floor. (Pg. 13,14,51) ___________________________
Veri ed replace is leveled and secured. (Pg. 33,54) ___________________________
Venting/Chimney Section 7 (Pg 36-41)
Venting con guration complies with allowable vent requirements.
Venting installed, locked and secured in place with proper clearances.
Interior/Exterior restops installed and sealed (In-Wall Installation only).
Attic insulation shield installed. (Pg 28)
Terminations/Roof ashing installed and sealed.
Termination cap extension installed and sealed (In-Wall Installation only)(Section 11)
___________________________
___________________________
___________________________
___________________________
___________________________
___________________________
Electrical Section 8 (Pg 42-43)
120VAC unswitched power provided to the appliance.
Veri ed ON/OFF switch wires properly installed.
Gas Section 9 (Pg 44-45)
Appliance con guration matches fuel type.
Was a conversion performed?
Leak check performed and inlet/outlet pressure veri ed.
Set air shutter for optimal ame appearance.
Finishing Section 10 (Pg 46-50)
Combustible materials not installed in non-combustible areas.
Veri ed all clearances meet installation manual requirements.
Mantels and wall projections comply with installation manual requirements.
___________________________
___________________________
___________________________
___________________________
___________________________
___________________________
___________________________
___________________________
___________________________
Appliance Setup Section 12 (Pg 59)
All packaging and protective materials are removed from inside/under /on
the appliance.
Glass assembly installed and secured, glass retainers removed,gasket sealed.
Accessories installed properly.
Mesh, doors, or decorative front properly installed.
Manual bag and all of its contents are removed from inside/under
the appliance and given to party responsible for use and operation.
Operated appliance. Veri ed no
gas leaks exist and proper appliance operation.
___________________________
___________________________
___________________________
___________________________
___________________________
___________________________
Hearth & Home Technologies recommends the following:
• Photographing the installation and copying this checklist for your le.
• This checklist remain visible at all times on the appliance until the installation is complete.
Comments: Further description of the issues, who is responsible (Installer/ Builder/ Other Trades, etc) and corrective action needed _____________________________________________________________________________________
_________________________________________________________________________________________________
Comments Communicated to party responsible ____________________ by ______________________on ___________
= Contains updated information.
2273-982E 9/14
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15 3
4
1
Product Specific and Important Safety Information
A. Appliance Certification D. High Altitude Installations
MODELS: Revo-V12, Revo-S21, Revo-H31
LABORATORY: Underwriters Laboratories, Inc. (UL)
NOTICE: If the heating value of the gas has been reduced, these rules do not apply. Check with your local gas utility or authorities having jurisdiction.
TYPE: Direct Vent Heater
When installing above 2000 feet elevation:
STANDARD: ANSI Z21.88-2014/CSA 2.33-2014
• In the USA: Reduce input rate 4% for each 1000 feet above 2000 feet.
This product is listed to ANSI standards fo “Vented Gas
Fireplace Heaters” and applicable sections of “Gas Burning Heating Appliances for Manufactured Homes and
Recreational Vehicles”, and “Gas Fired Appliances for
Use at High Altitudes”.
• In CANADA: Input ratings are certified without a reduction of input rate for elevations up to 4500 feet (1370 m) above sea level. Please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4500 feet (1370 m).
NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemental room heat or as a decorative appliance. It should not be factored as primary heat in residential heating calculations.
Check with your local gas utility to determine proper orifice size.
E. Non-Combustible Materials Specification
Material which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, concrete, slate, glass or plasters, or any combination thereof.
Materials that are reported as passing
ASTM E 136,
Standard Test Method for Behavior of Materials in
a Vertical Tube Furnace at 750 ºC shall be considered non-combustible materials.
B. Glass Specifications
This appliance is equipped with 5 mm ceramic glass. Replace glass only with 5 mm ceramic glass. Please contact your dealer for replacement glass.
C. BTU Specifications
Models
(U.S. or Canada)
Maximum
Input BTU/h
Revo-V12
(NG)
Revo-V12
(LP)
Revo-S21
(NG)
Revo-S21
(LP)
Revo-H31
(NG)
Revo-H31
(LP)
(0-2000 FT)
14,250
(0-2000 FT)
13,350
Minimum
Input
BTU/h
8,200
8,500
(0-2000 FT)
18,800 10,900
Orifice
Size (DMS)
#50
#58
.083 in.
(0-2000 FT)
18,950 10,800 1.25 mm
(0-2000 FT)
24,000 12,700
(0-2000 FT)
20,000 10,850
#42
0.053 in.
F. Combustible Materials Specification
Materials made of or surfaced with wood, compressed paper, plant fibers, plastics, or other material that can ignite and burn, whether flame proofed or not, or plastered or unplastered shall be considered combustible materials.
G. Electrical Codes
NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with
National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
• A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks.
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
Note: The following requirements reference various
Massachusetts and national codes not contained in this document.
H. Requirements for the Commonwealth of
Massachusetts
For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:
Installation of Carbon Monoxide Detectors
At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gas fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gas fitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors.
In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.
In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.
Approved Carbon Monoxide Detectors
Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA
720 and be ANSI/UL 2034 listed and IAS certified.
Signage
A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) in. in size,
“GAS
VENT DIRECTLY BELOw. KEEP CLEAR OF ALL OB-
STRUCTIONS”.
Inspection
The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.
Exemptions
The following equipment is exempt from 248 CMR
5.08(2)(a)1 through 4:
• The equipment listed in Chapter 10 entitled “Equipment
Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and
• Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.
MANUFACTURER REQUIREMENTS
Gas Equipment Venting System Provided
When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
• Detailed instructions for the installation of the venting system design or the venting system components; and
• A complete parts list for the venting system design or venting system.
Gas Equipment Venting System NOT Provided
When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies
“special venting systems”, the following requirements shall be satisfied by the manufacturer:
• The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and
• The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.
A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.
See Gas Connection section for additional Commonwealth of Massachusetts requirements.
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15 5
2
Getting Started
A. Design and Installation Considerations
Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
No additional outside air source is required.
Installation MUST comply with local, regional, state and national codes and regulations. Consult insurance carrier, local building inspector, fire officials or authorities having jurisdiction over restrictions, installation inspection and permits.
Before installing, determine the following:
• Where the appliance is to be installed.
• Whether the REVO will be installed On-Wall or In-Wall
(See Section 2.D),
• The vent system configuration to be used.
• Gas supply piping requirements.
• Electrical wiring requirements.
• Framing and finishing details.
• Whether optional accessories—devices such as a wall switch or remote control—are desired.
C. Inspect Appliance and Components
• Carefully remove the appliance and components from the packaging.
• The vent system components and decorative doors and fronts may be shipped in separate packages.
• Report to your dealer any parts damaged in shipment, particularly the condition of the glass.
•
Read all of the instructions before starting the installation. Follow these instructions carefully during the installation to ensure maximum safety and benefit.
WARNING! Risk of Fire or Explosion! Damaged parts could impair safe operation. DO NOT install damaged, incomplete or substitute components. Keep appliance dry.
Installation and service of this appliance should be performed by qualified personnel. Hearth & Home
Technologies suggests NFI certified or factory trained professionals, or technicians supervised by an NFI certified professional (www.nficertified.org).
Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions:
• Installation and use of any damaged appliance or vent system component.
• Modification of the appliance or vent system.
• Installation other than as instructed by Hearth & Home
Technologies.
• Improper positioning of the gas logs or the glass door.
• Installation and/or use of any component part not approved by Hearth & Home Technologies.
Any such action may cause a fire hazard.
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information, consult a qualified service technician, service agency or your dealer.
WARNING! Risk of Fire, Explosion or Electric Shock!
DO NOT use this appliance if any part has been under water. Call a qualified service technician to inspect the appliance and to replace any part of the control system and/or gas control which has been under water.
6
B. Tools and Supplies Needed
Before beginning the installation be sure that the following tools and building supplies are available.
Tape measure Framing material
Pliers Hammer
Phillips screwdriver Manometer
Gloves
Voltmeter
Framing square
Tin Snips
Plumb line
Level
Safety glasses
Reciprocating saw
Stud Finder Flat blade screwdriver
Electric drill: 1/2 in. bit, 1/4 in. masonry bit (masonry wall installation only)
Non-corrosive leak check solution
1/2 - 3/4 in. length, #6 or #8 Self-drilling screws
Caulking material (300ºF minimum continuous exposure rating)
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
D. Installation Methods:On-Wall or In-Wall
When installing the REVO model, you may choose from one of two installation options.
1. On-Wall Installation:
The REVO can hang on a sheet rock/combustible wall
2. In-Wall Installation:
The REVO can be partially recessed into a wall using the In-Wall Tub Assembly
The On-Wall installation is the most common and least difficult method. On-Wall installation information is located in Sections 3, 6, and 10. In-Wall installation information is isolated in Section 11. Section 11 will discuss preparation, clearances and finishing specific to the In-Wall method. Consult the table of contents for topics common to both methods, such as vent configurations, gas and electrical information.
On-Wall Installation
The REVO can hang on a sheet rock/combustible wall.
See Sections 3, 6 and 10 for On-Wall installation information.
In-Wall Installation
The REVO can be partially recess into a wall using the In-Wall Kit. See Service Parts section in Owner’s
Manual and contact your dealer to order. See Section
11 for installation information.
TOP VIEW
VERTICAL
2 X 6 STUDS
MATERIAL CAN BE
COMBUSTIBLE
I.E. SHEETROCK
2 X 6 HEADER
FRAMING
FRAMING + SHEETROCK
SIDE VIEW
(DECORATIVE FRONT INSTALLED)
CUT OUT MATERIAL
FOR VENT
7-5/16 IN.
BEFORE
AFTER
2 IN.
TUB ASSEMBLY
TOP VIEW WITH
TUB INSTALLED
INSULATION ZONE
TUB ASSEMBLY
3-1/2 IN.
SIDE VIEW
(DECORATIVE FRONT INSTALLED)
4-13/16 IN.
APPLIANCE
OUTER WRAP
FRAMING + SHEETROCK
+ APPLIANCE OUTER WRAP
APPLIANCE
OUTER WRAP
FRAMING + SHEETROCK
+ APPLIANCE OUTER WRAP + HOLE CUT
RECESSED
IN-WALL TUB
NON-COMBUSTIBLE
BOARD
SHEETROCK/COMBUSTIBLE
FACING MATERIAL
FRAMING FRAMING + IN-WALL TUB
+ APPLIANCE
NON-COMBUSTIBLE
BOARD
APPLIANCE
INSTALLED
FINISHED INSTALLATION
Figure 2.1 On-Wall Installation Method Figure 2.2 In-Wall Installation Method
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
4 IN. TO
FINISHED
FLOOR
7
3
Framing and Clearances
A. Appliance/Decorative Front Dimension Diagrams
Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 3 and Section 5.
REVO-V12
M
L
H
I
C
B
A
G
F
J
E
D
Appliance Dimensions Table
Location Inches Millimeters
A 36-1/8 918
B 12 305
C
D
24
16-5/8
610
422
E
F
G
H
19-1/4
6-1/8
28-1/2
9-5/8
489
156
724
245
K
L
M
J
I 6-5/8
3
4-1/4
6-3/8
7-7/8
168
76
108
162
200
Figure 3.1 Appliance Dimensions - Revo-V12
8 Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
K
REVO-S21
M
L
H
I
A
C
B
G
F
J
E
D
Figure 3.2 Appliance Dimensions - Revo-S21
Appliance Dimensions Table
Location Inches Millimeters
A 33-5/8 854
B
C
21-1/8
21-3/8
537
543
F
G
H
I
D
E
25-3/4
28-1/2
6-1/4
26
14-1/4
6-5/8
654
724
159
660
362
168
L
M
J
K
3
4-5/16
6-3/8
7-7/8
76
109
162
200
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
K
9
REVO-H31
M
A
C
B
D
E
Figure 3.3 Appliance Dimensions - Revo-H31
F
G
J
Appliance Dimensions Table
J
I
G
H
K
L
M
Location Inches Millimeters
A 29-1/8 740
B
C
31
17
787
432
D
E
F
35-5/8
38-1/4
6-1/8
905
972
156
21-1/2
19-1/8
6-5/8
3
4-3/16
6-3/8
7-7/8
546
486
168
76
106
162
200
L
H I
K
10 Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
See Section 10.A, 10.B, 10.C, and 11.C for facing and finishing detail.
STUDIO/FRAME DECORATIVE FRONTS
REVO-V12
REVO-S21
39-1/2 IN.
36-15/16 IN.
27-5/8 IN.
36-5/8 IN.
Figure 3.4 Appliance Dimensions - Studio and Frame Decorative Fronts
RADIUS DECORATIVE FRONT
REVO-V12 REVO-S21
37-15/16 IN.
34-1/8 IN.
32-11/16 IN.
30-3/16 IN.
REVO-H31
46-15/16 IN.
REVO-H31
23-1/2 IN.
32-3/4 IN.
42-9/16 IN.
Figure 3.5 Appliance Dimensions - Radius Decorative Front
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15 11
B. Clearance to Combustibles
When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure
3.6).
WARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access.
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
NOTICE: Illustrations reflect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams are not drawn to scale. Actual installation may vary due to individual design preference.
WARNING! Risk of Fire! Maintain specified air space clearances to appliance and vent pipe:
• Insulation and other materials must be secured to prevent accidental contact.
• The chase must be properly blocked to prevent blown insulation or other combustibles from entering and making contact with fireplace or chimney.
• Failure to maintain airspace may cause overheating and a fire.
See Figure 3.6, 3.7, 3.8, 3.9, and 3.11 for framing dimension requirements and required clearances.
17-5/16 IN.
(440 mm)
1 IN. MINIMUM
(25 mm)
15-3/8 IN.
(391 mm)
ZERO CLEARANCE
12 IN.
(305 mm)
REVO-V12
REVO-S21
REVO-H31
12 IN.
(305 mm)
REVO-V12
34-5/16 IN.
(872 mm)
1 IN. MINIMUM
(25 mm)
REVO-V12
(941 mm)
Refer to Sections 10.D and 10.E for mantel and wall projection information.
50-13/16 IN.
REVO-H31
41 IN.
(1041 mm)
REVO-S21
27-1/16 IN.
(687 mm)
ZERO CLEARANCE
20-1/8 IN.
(511 mm)
Note: The REVO-V12 is the only REVO appliance that can be vented with a 45 degree elbow directly off the back positioned horizontally. See Section 4.F.
Figure 3.6 Appliance Locations
12 Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
C. Constructing the Appliance Chase
A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should be enclosed inside the chase.
NOTICE: Treatment of ceiling firestops and wall shield firestops and construction of the chase may vary with the type of building. These instructions are not substitutes for the requirements of local building codes. Therefore, you MUST check local building codes to determine the requirements to these steps.
To further prevent drafts, the wall shield and ceiling firestops should be caulked with caulk with a minimum of
300ºF continuous exposure rating to seal gaps. Gas line holes and other openings should be caulked with caulk with a minimum of 300ºF continuous exposure rating or stuffed with unfaced insulation. If the appliance is being installed on a cement surface, a layer of plywood may be placed underneath to prevent conducting cold up into the room.
D. Floor Protection
WARNING! Risk of overheating! Install appliance a minimum of 4 inches off of finished floor.
• Convection air flow could be compromised and cause overheating.
• Decorative fronts will not fit properly.
• The finished floor below the appliance does not have to be non-combustible, due to the required 4 inch minimum clearance from bottom of appliance to finished floor.
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15 13
E. Clearances (On-Wall and In-Wall)
WARNING! Risk of overheating! Install appliance a minimum of 4 inches off of finished floor.
• Convection air flow could be compromised and cause overheating.
• Decorative fronts will not fit properly.
APPLIANCE OUTER
WRAP
A
(CUT OUT MATERIAL
F
FOR VENT PIPE)
B
(TO CEILING)
E
D
C
G
Figure 3.7
14
MODEL
Revo-V12
Revo-S21
Revo-H31 in.
mm in.
mm in.
mm
MINIMUM CLEARANCES FROM APPLIANCE OUTER wRAP
A B C D* E** F***
Rough
Opening
(Vent Pipe)
Clearance to Ceiling
Minimum
Clearance to Finished
Floor
Clearance to
Combustible
Flooring
Behind
Appliance
Outer
Wrap
Clearance to
Adjacent
Wall
G
Front of
Appliance
Measured from
Mesh
10-1/8 22 4 0 0 12 36
257
10-1/8
257
10-1/8
257
559
22
559
22
559
102
4
102
4
102
0
0
0
0
0
0
0
0
0
0
D* = Clearance to combustible floor not required due to 4 inch minimum on Dimension C.
E** = The appliance outer wrap can attach directly to combustible material, i.e. sheetrock.
F*** = See Section 10.D and 10.E for combustible and non-combustible mantel legs.
305
12
305
12
305
914
36
914
36
914
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
1-5/8 IN.
CLEAR SPACE
3 FT. IN
FRONT OF
FIREPLACE
MESH
FLOOR CAN BE
COMBUSTIBLE
4 IN. MIN.TO
FINISHED FLOOR
CUT LINE
NOTE: The firestop heat shield will need to be cut when using an elbow directly off the back of the appliance. See Figure 3.9.
Figure 3.10 Wall Firestop Clearances
Figure 3.8 Clear Space Requirement - All Models
F. Clearances - Venting with an Elbow
Directly Off the Back of Appliance
IN WALL ON WALL
FRAMING HEADER TURNED VERTICAL
FOR CLEARANCE
13-1/4 IN.
COMBUSTIBLE
ZONE
SHEETROCK/
COMBUSTIBLE
MATERIAL
COMBUSTIBLE
ZONE
SHEETROCK/
COMBUSTIBLE
MATERIAL
1-1/2 IN. PIPE CLEARANCE
IN ZONE ABOVE ELBOW
AND BEHIND APPLIANCE
OUTER WRAP
ZERO CLEARANCE
APPLIANCE
OUTER WRAP
10-3/4 IN.
NOTE: VERTICAL WALL
STUDS NOT SHOWN
ATTIC ABOVE
9 IN.
9 IN.
Figure 3.9 Clearance Requirements
Note: The firestop shield will need to be trimmed when venting with a 90 degree elbow directly off the back of the appliance. See Figure 3.10.
Figure 3.11 Ceiling Penetration Framing Requirements
See Section 5 for information regarding ceiling firestop.
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15 15
4
Termination Location and Vent Information
A. Vent Termination Minimum Clearances
wARNING
A
6 in. (minimum) up to 20 in.
152 mm/508 mm
20 in. and over
Fire Risk.
Maintain vent clearance to combustibles as specified.
• DO NOT pack air space with insulation or other materials.
Failure to keep insulation or other materials away from vent pipe may cause overheating and fire.
B
Gas, Wood or Fuel Oil
Termination Cap
B
18 in. minimum
457 mm
0 in. minimum
A *
HORIZONTAL
OVERHANG
Gas
Termination
Cap **
2 FT.
MIN.
20 INCHES MIN.
LOWEST
DISCHARGE
OPENING
VERTICAL
WALL
GAS DIRECT VENT
TERMINATION CAP
12
X
ROOF PITCH
IS X/ 12
H (MIN.) - MINIMUM HEIGHT FROM ROOF
TO LOWEST DISCHARGE OPENING
**
*
If using decorative cap cover(s), this distance may need to be increased. Refer to the installation instructions supplied with the decorative cap cover.
In a staggered installation with both gas and wood or fuel oil terminations, the wood or fuel oil termination cap must be higher than the gas termination cap.
Figure 4.2 Staggered Termination Caps
Roof Pitch H (Min.) Ft.
Flat to 6/12...........................................................1.0*
Over 6/12 to 7/12 .................................................1.25*
Over 7/12 to 8/12 .................................................1.5*
Over 8/12 to 9/12 .................................................2.0*
Over 9/12 to 10/12 ...............................................2.5*
Over 10/12 to 11/12 .............................................3.25
Over 11/12 to 12/12 .............................................4.0
Over 12/12 to 14/12 .............................................5.0
Over 14/12 to 16/12 .............................................6.0
Over 16/12 to 18/12 .............................................7.0
Over 18/12 to 20/12 .............................................7.5
Over 20/12 to 21/12 .............................................8.0
* 3 foot minimum in snow regions
Figure 4.1 Minimum Height From Roof To Lowest Discharge
Opening
16 Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
B. Chimney Diagram
O
N
P
C
F
V
J
B
V
B
V
B
D
V
G
V
M
A
V
= VENT TERMINAL
X
= AIR SUPPLY INLET
= AREA wHERE TERMINAL IS NOT PERMITTED
A = 12 inches.................clearances above grade, veranda, porch, deck or balcony
12 inches.................clearance to window or door that may be opened, or to permanently closed window
V
R
Q
X
H or i
V
V
H
H
V
E
V
A
V
K
V
L
Electrical
Service
C
K
V
V
Covered Alcove Applications
(Spaces open only on one side and with an overhang)
N = 6 inches ........... non-vinyl sidewalls
12 inches ......... vinyl sidewalls
18 inches.................clearance below ventilated soffit
30 inches .................clearance below vinyl soffits and electrical service
D = 9 inches...................clearance to outside corner
E = 6 inches...................clearance to inside corner
F = 3 ft. (Canada) ..........not to be installed above a gas meter/regulator assembly within 3 feet horizontally from the center-line of the regulator
G = 3 ft ...........................clearance to gas service regulator vent outlet
H = 9 inches (U.S.A)
12 inches (Canada). clearance to non-mechanical (unpowered) air supply inlet, combustion air inlet or direct-vent termination i = 3 ft. (U.S.A.)
6 ft. (Canada) ...........clearance to a mechanical (powered) air supply inlet
All mechanical air intakes within 10 feet of a termination cap must be a minimum of 3 feet below termination.
J = 7 ft. ......................... On
public property: clearance above paved sidewalk or a paved driveway.
A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.
42 inches ......... vinyl soffit and overhang
P = 8 ft.
1 cap
Q
MIN
3 feet
R
MAX
2 x Q
ACTUAL
2 caps
3 caps
4 caps
6 feet
9 feet
12 feet
1 x Q
ACTUAL
2/3 x Q
ACTUAL
1/2 x Q
ACTUAL
Q
MIN
= # termination caps x 3 R
MAX
= (2 / # termination caps) x Q
ACTUAL
Measure vertical clearances from this surface.
CLEARANCE = 6 IN.
Measure horizontal clearances from this surface.
K = 6 inches................. clearance from sides of electrical service
L = 12 inches................ clearance above electrical service
Location of the vent termination must not interfere with access to the electrical service.
M = 18 inches ....................clearance under veranda, porch, deck, balcony or overhang
42 inches ................vinyl or composite overhang
Permitted when veranda, porch, deck or balcony is fully open on a minimum of 2 sides beneath the floor.
Figure 4.3 Minimum Clearances for Termination
CAUTION! Risk of Burns! Termination caps are HOT, consider proximity to doors, traffic areas or where people may pass or gather (sidewalk, deck, patio, etc.). Listed cap shields available. Contact your dealer.
• Local codes or regulations may require different clearances.
• Vent system termination is NOT permitted in screened porches.
• Vent system termination is permitted in porch areas with two or more sides open.
• Hearth & Home Technologies assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements.
• Vinyl protection kits are suggested for use with vinyl siding.
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15 17
C. Approved Pipe
This appliance is approved for use with Hearth & Home
Technologies SLP venting systems. Refer to Section
13.A for vent component information and dimensions.
DO NOT mix pipe, fittings or joining methods from different manufacturers.
The pipe is tested to be run inside an enclosed wall.
There is no requirement for inspection openings at each joint within the wall.
WARNING! Risk of Fire or Asphyxiation. This appliance requires a separate vent.
DO NOT vent to a pipe serving a separate solid fuel burning appliance.
D. Use of Elbows
Diagonal runs have both vertical and horizontal vent aspects when calculating the effects. Use the rise for the vertical aspect and the run for the horizontal aspect. See
Figure 4.4.
Two 45º elbows may be used in place of one 90º elbow.
On 45º runs, one foot of diagonal is equal to 8-1/2 in. (216 mm) horizontal run and 8-1/2 in. (216 mm) vertical run. A length of straight pipe is allowed between two 45º elbows.
See Figure 4.4.
Figure 4.5 shows the vertical and horizontal offsets for
SLP elbows.
Y
SLP
X
X Y
Inches Millimeters Inches Millimeters
5 127 11-3/4 298
X
VERTICAL
FE
CT
IVE
EF
LE
NG
TH
RUN
X
Vent Type
SLP
Inches
11-1/4
X
Millimeters
286
Figure 4.5 Vertical and Horizontal Offset for SLP Elbows
HORIZONTAL
SLP
Pipe
SLP4
SLP6
SLP12
SLP24
SLP36
SLP48
Effective Length
Inches Millimeters
4
6
12
24
36
48
102
152
305
610
914
1219
Inches
Rise/Run
Millimeters
2-3/4
4-1/4
8-1/2
17
25-1/2
34
SLP6A 3 to 6 76 to 152 2-1/8-4-1/4
SLP12A 3 to 12 76 to 305 2-1/8-8-1/2
70
108
216
432
648
864
54-108
54-216
Figure 4.4
18 Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
E. Measuring Standards
Vertical and horizontal measurements listed in the vent diagrams were made using the following standards.
• Pipe measurements are shown using the effective length of pipe. See Section 13.A for information on effective length of pipe components.
• Horizontal terminations are measured to the outside mounting surface (flange of termination cap) (see Figure
4.3).
• Vertical terminations are measured to bottom of termination cap.
• Horizontal pipe installed level with no rise.
F. Vent Diagrams
General Rules:
• 90º elbows can be replaced with two 45º elbows.
• SUBTRACT 3 ft. from the total H measurement for each
90º elbow installed horizontally.
• SUBTRACT 1-1/2 ft. from the total H measurement for each 45º elbow installed horizontally.
• A maximum of three 90º elbows (or six 45º elbows) may be used in any vent configuration. Some elbows may be installed horizontally. See Figure 4.9 and Figure 4.12 .
• When penetrating a combustible wall, a wall shield firestop must be installed. See Figure 5.1.
• When penetrating a combustible ceiling, a ceiling firestop must be installed. See Figure 5.4.
• Horizontal runs of vent do not require vertical rise; horizontal runs may be level.
• Horizontal termination cap should have a 1/4 inch downward slant to allow any moisture in cap to be released. See Figure 4.6.
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15 19
Horizontal Termination
No Elbow
H
H = 12 in. (305 mm) Maximum
Figure 4.6
One 45º Elbow
Note: This vent configuration is not allowed with the REVO-S21 or REVO-H31 models.
H
V12
S21
H31
H Maximum
12 in. (305 mm)
Not allowed
Not allowed
Figure 4.7
20 Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
Horizontal Termination - (continued)
Two Elbows
V
1
Minimum
Two 90º Elbows back to back
1 ft 305 mm
H
1
+ H
2
Maximum
1 ft 305 mm
4 ft 1.2 m
2 ft
3 ft
4 ft
5 ft
610 mm
914 mm
1.2 m
1.5 m
7 ft
10 ft
13 ft*
14 ft*
2.1 m
3.0 m
4.0 m*
4.3 m*
6 ft
7 ft
1.8 m
2.1 m
14 ft*
14 ft*
4.3 m*
4.3 m*
H
Total
V
1
+ H
1
+ H
2
= 40 ft. (12.2 m) Maximum
* : REVO-S21 & REVO-H31= 14 ft. (4.3 m) Maximum
: REVO-V12 = 12 ft. (3.7 m) Maximum
H
2
V
1
Figure 4.8
Three Elbows
H
3
H
2
H
1
V
1
Minimum
1 ft 305 mm
2 ft
3 ft
4 ft
610 mm
914 mm
1.2 m
H
1
+ H
2
+ H
3
Maximum
2 ft 610 mm
5 ft
8 ft
11 ft
1.5 m
2.4 m
3.4 m
5 ft
6 ft
1.5 m
1.8 m
14 ft*
14 ft*
4.3 m*
4.3 m*
7 ft 2.1 m 14 ft* 4.3 m*
H
Total
V
1
+ H
1
+ H
V
1
2
+ H
3
= 40 ft. (12.2 m) Maximum
= 1 ft (305 mm) Minimum
* : REVO-S21 & REVO-H31= 14 ft. (4.3 m) Maximum
: REVO-V12 = 12 ft. (3.7 m) Maximum
V
1
Figure 4.9
H
1
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15 21
Vertical Termination
One Elbow
V
1
Figure 4.10
Two Elbows
2 ft
3 ft
4 ft
5 ft
6 ft
V
1
Minimum
610 mm
914 mm
1.2 m
1.5 m
1.8 m
H
1
5 ft
8 ft
Maximum
11 ft
14 ft*
14 ft*
1.5 m
2.4 m
3.4 m
4.3 m*
4.3 m*
7 ft 2.1 m 14 ft* 4.3 m*
V
1
+ H
V
1
= 40 ft (12.2 m) Maximum
1
= 2 ft (610 mm) Minimum
H
Total
* : REVO-S21 & REVO-H31= 14 ft. (4.3 m) Maximum
: REVO-V12 = 12 ft. (3.7 m) Maximum
H
1
2 ft
V
1
Minimum
610 mm
3 ft 914 mm
H
1
+ H
2
Maximum
4 ft 1.2 m
7 ft 2.1 m
4 ft
5 ft
6 ft
7 ft
1.2 m
1.5 m
1.8 m
2.1 m
10 ft
13 ft*
14 ft*
14 ft*
3.0 m
4.0 m*
4.3 m*
4.3 m*
8 ft 2.4 m 14 ft* 4.3 m*
H
Total
V
1
+ H
1
V
1
+ H
2
= 40 ft (12.2 m) Maximum
= 2 ft (610 mm) Minimum
* : REVO-S21 & REVO-H31= 14 ft. (4.3 m) Maximum
: REVO-V12 = 12 ft. (3.7 m) Maximum
V
1
Figure 4.11
22
H
2
H
1
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
Vertical Termination - (continued)
Three Elbows
V
2
V
1
Minimum
2 ft 610 mm 6 ft
H
1
+ H
2
Maximum
1.8 m
3 ft
4 ft
5 ft
914 mm
1.4 m
1.5 m
9 ft
12 ft
14 ft*
2.7 m
3.6 m
4.3 m*
6 ft
7 ft
1.8 m
2.1 m
14 ft*
14 ft*
4.3 m*
4.3 m*
V1 + V2 + H1 + H2 = 40 ft (12.2 m) Maximum
V
Total
= 2 ft (610 mm) Minimum
H
Total
* : REVO-S21 & REVO-H31= 14 ft. (4.3 m) Maximum
: REVO-V12 = 12 ft. (3.7 m) Maximum
H
2
V
1
Figure 4.12
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
H
1
23
Vertical Termination - (continued)
One Elbow
Note: If the vertical component of the vent configuration is 10 feet or greater, the baffle may need to be adjusted as noted in this section. The air shutter may also need adjustment.
See Section 9.E.
V1 Maximum = 40 ft (12.2 m)
Vent Configurations with Vertical
Components in Excess of 10 Feet
The Revo model is shipped with an adjustable baffle shipped in the full open position. See Figure 4.15. The baffle may need to be adjusted if the vertical component of the vent configuration is 10 feet or greater. See the chart in Figure 4.14 to determine the correct setting for the application being installed. Closing the air shutter and baffle will improve the flame height if the vent configuration involves a significant amount of vertical venting. If the baffle is closed too far, pilot starvation and/or sooting may occur. Ensure the baffle screw(s) is/are secure once the adjustment is made.
ADJUSTABLE BAFFLE OPENINGS
V
1
Figure 4.15 Adjustable Baffle Location
Figure 4.13 Vertical Venting With One Elbow
VERTICAL DIMENSION
10-20 ft.
21-30 ft.
30 ft. or more
Z
V12(NG/LP)
1-1/4 in.
1-1/8 in.
1 in.
BAFFLE SETTING
Z Dimension (Below)
S21 (NG/LP)
2-1/4 in.
2-1/8 in.
2 in.
H31 (NG)
2-1/4 in.
2-1/8 in.
2 in.
ADJUSTMENT SCREW(S)
Z
H31 (LP)
1-3/4 in.
1-5/8 in.
1-1/2 in.
BAFFLE
OPENINGS
Note: The REVO-H31 will have two adjustment screws and a fixed center baffle opening.
Figure 4.14 Baffle Settings
24 Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
Coaxial to Colinear Venting
The coaxial to colinear adapter (DV-46DVA-GCL) is approved for installations into solid fuel masonry or factory built fireplaces that have been installed in accordance with the National, Provincial, State and local building codes. The DV-46DVA-GCL must be recessed into existing masonry fireplace. See Table 1 and Figure 4.16.
INLET AIR VENT PIPE
EXHAUST VENT PIPE
OUTSIDE FACE OF
FIREPLACE
EXHAUST VENT PIPE
TOP OF FIREPLACE
OPENING
5 IN. MIN.
3 IN. MIN.
SHADED AREA DEFINED AS
“INSIDE EXISTING MASONRY
FIREPLACE”
Figure 4.16. Coaxial/Colinear Appliance Connector
WARNING! Risk of Fire! Coaxial to colinear venting configuration may only be used in existing non-combustible chimney. Installation in any other venting application could cause fire.
Prior to installing the gas appliance:
• Have the chimney and adjacent structure inspected and cleaned by qualified professionals. Hearth & Home
Technologies recommends that NFI or CSIA certified professionals, or technicians under the direction of certified professionals, conduct a minimum of a NFPA 211
Level 2 inspection of the chimney.
• Replace component parts of the chimney and fireplace as specified by the professionals.
• Ensure all joints are properly engaged and the chimney is properly secured.
Table 1
CLEARANCE TO COMBUSTIBLES REQUIREMENTS
DV-46DVA-GCL 3 IN.
Exhaust Vent Pipe 5 IN.
Figure 4.17. Existing Fireplace DV-46DVA-GCL
Clearance Requirements
Clearances to Combustibles:
Refer to Section 10 and Section 11 for clearances to the appliance, mantel, mantel legs and wall projection.
Refer to Section 5 for pipe clearances to combustibles.
Termination Cap
For installation of termination cap see minimum vent heights for various pitched roofs. See Section 4.
Flue Baffle
Fully lock the fireplace’s flue baffle in the open position,
OR completely remove it. See Figure 4.14.
Venting Components
The LINK-DV30B is approved for use with the coaxial/colinear venting application. The LINK-DV30B kit includes:
• Two 30 feet sections of flexible vent pipe (3 inches Ø).
One section is used to draw combustion air and the other section is used to expel exhaust gases.
• One vertical termination cap.
CAUTION! DO NOT use any flue restrictor when venting with the DV-46DVA-GCL adapter and LINK-DV30B
kit. This may result in poor flame appearance, sooting, pilot malfunction, or overheating.
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15 25
Connecting the DV-46DVA-GCL Adapter to Appliance
Rear Vent
• Connect the vertically positioned elbow. Secure
DV-46DVA-GCL adapter to the elbow with 3-1/2 in. selftapping screws. See Figure 4.18.
Connecting the LINK-DV30B to the DV-46DVA-GCL adapter
• Insert the two sections of flexible vent pipe down the existing chimney.
• Attach one section of stainless steel flex pipe to the exhaust collar on top of the DV-46DVA-GCL adapter with three screws.
• Attach one section of flexible vent pipe to the stainless steel flex pipe with three self-tapping screws.
• Attach one section of flexible vent pipe to the inlet collar on top of the DV-46DVA-GCL adapter with three selftapping screws.
• To minimize cold air drafts, seal around the flex vents at the damper inside the chimney with non-combustible unfaced fiberglass or rock wool insulation.
The DV-46DVA-GCL adapter must be recessed into existing masonry fireplace. This measurement is taken from the top of the fireplace opening. See Table 1 and Figure 4.17.
WARNING! Risk of Fire, Explosion or Asphyxiation!
Do NOT connect this gas appliance to a chimney flue serving a separate solid fuel or gas burning appliance.
• May impair safe operation of this appliance or other appliances connected to the flue.
• Vent this appliance directly outside.
• Use separate vent system for this appliance.
TERMINATION CAP
V
CAUTION! DO NOT use any flue restrictor when venting with the DV-46DVA-GCL
adapter and LINK-DV30B kit. This may result in poor flame appearance, sooting, pilot malfunction, or overheating.
NOTICE: To achieve optimum performance of appliance, minimize or avoid bends in exhaust vent pipe.
EXISTING CHIMNEY
EXHAUST AIR
VENT PIPE
EXISTING CHIMNEY
COAXIAL/COLINEAR
APPLIANCE CONNECTOR
DIRECT VENT FIREPLACE
INLET AIR VENT PIPE
The first 3 feet of exhaust flue must be stainless flex pipe.
To minimize cold air drafts, seal with non-combustible insulation.
26
Figure 4.18
4 IN. MIN.
FLOOR
HEARTH
H
Minimum
Maximum
10 ft.
40 ft.
V
3.05 m
12.2 m
0 ft.
H
0 mm
2 ft.
610 mm
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
5
Vent Clearances and Framing
A. Pipe Clearances to Combustibles
WARNING! Risk of Fire! Maintain air space clearance to vent. DO NOT pack insulation or other combustibles:
• Between ceiling firestops
• Between wall shield firestops
• Around vent system
Failure to keep insulation or other material away from vent pipe may cause overheating and fire.
Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm).
• SLP heat shield - designed to be used on a wall 4-3/8 in. to 7-5/8 in. (111 mm to
194 mm thick).
• If wall thickness is less than 4-3/8 the existing heat shields must be field trimmed.
If wall thickness is greater than 7-5/8 in. a DVP-HSM-B will be required.
(SLP Pipe Shown)
3 in. (76 mm) top clearance *
Heat
Shield
Heat
Shield
• SLP pipe - A wall shield firestop must be placed on each side of an interior wall. A minimum 1-1/2 in. (38 mm) overlap of attached heat shields must be maintained.
• See Section 7.F. for information for regarding the installation of a horizontal termination cap.
Non-Combustible Wall Penetration
If the hole being penetrated is surrounded by non-combustible materials such as concrete, a hole with diameter one inch greater than the pipe is acceptable.
Whenever a non-combustible wall is penetrated, the wall shield firestop is only required on one side and no heat shield is necessary.
WARNING! Risk of overheating! Install appliance a minimum of 4 inches off of finished floor.
• Convection air flow could be compromised and cause overheating.
• Decorative fronts will not fit properly.
Wall
Shield
Firestop
WALL
1 in. (25 mm) clearance bottom & sides
DO NOT PACK WITH
INSULATION OR
OTHER MATERIAL
B
A
12 IN.
10-3/16 iN.
* When using SLP pipe, minimum clearances from the vent pipe to combustible materials at inside wall firestops are: Top: 2-1/2 in. (64 mm)
Bottom: 1/2 in. (13 mm)
Sides: 1 in. (25 mm)
C
FINISHED
FLOOR
Figure 5.1 Horizontal Venting Clearances To Combustible
Materials
Note: Vertical venting requires 1 inch clearance on all sides of the pipe.
B. Wall Penetration Framing/Firestops
Combustible wall Penetration
Whenever a combustible wall is penetrated, you must frame a hole for the wall shield firestop(s). The wall shield firestop maintains minimum clearances and prevents cold air infiltration.
• The opening must be framed on all four sides using the same size framing materials as those used in the wall construction.
Revo-V12
Revo-S21
Revo-H31 in.
mm in.
mm in.
mm
A
= 4 in.min.
(102 mm)
B
28-1/2
724
26
660
21-1/2
546
C*
C=(A + B) +1 in.
(1 in. =25 mm)
* Shows center of vent framing hole for venting. The center of the hole is one (1) inch (25.4 mm) above the center of the horizontal vent pipe.
Figure 5.2 Wall Penetration
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15 27
C. Ceiling Firestop/Floor Penetration Framing
A ceiling firestop MUST be used between floors and attics.
• Frame opening 9 in. x 9 in. (229 mm x 229 mm) whenever the vent penetrates a ceiling/ floor. See Figure 5.3.
• Frame the area with the same sized lumber as used in ceiling/floor joist.
• The ceiling firestop may be installed above or below the ceiling joists when installed with a attic insulation shield. It must be under joists between floors that are not insulated. Refer to Figure 5.4.
• Secure with three fasteners on each side.
WARNING! Risk of Fire! DO NOT pack insu-
lation around the vent. Insulation must be kept back from the pipe to prevent overheating.
ATTIC ABOVE
A
A
PIPE
SLP
A
9 in. (229 mm)
D. Install Attic Insulation Shield
WARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth
& Home Technologies requires the use of an attic shield.
The International Fuel Gas Code requires an attic shield constructed of 26 gauge minimum steel that extends at least 2 in. (51 mm) above insulation.
• Attic insulation shields must meet specified clearances to combustible materials and be secured in place.
• An attic insulation shield kit is available from
Hearth & Home Technologies. Contact your dealer to order. Install attic insulation shield according to instructions included with kit.
Figure 5.3 Installing Ceiling Firestop
INSTALL ATTIC INSULATION SHIELDS
BEFORE OR AFTER INSTALLATION OF VENT SYSTEM
28
CEILING FIRESTOP
INSTALLED BELOW CEILING
Figure 5.4 Installing the Attic Shield
CEILING FIRESTOP
INSTALLED ABOVE CEILING
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
6
Appliance Preparation
A. Vent Collar Preparation - Sealing the
Firestop
CAUTION! Risk of Cuts, Abrasions or Flying Debris.
Wear protective gloves and safety glasses during installation. Sheet metal edges are sharp.
NOTICE: Cold air infiltration may occur if firestop is not sealed correctly.
1. Seal the firestop on the interior and exterior by caulking around the perimeter using caulk with a 300ºF minimum continuous exposure rating. See Figure 6.1. and 6.2.
WARNING! Risk of Fire or Explosion! DO NOT break caulk seals on slip sections. Use care when removing termination cap from slip pipe. If slip section seals are broken during removal of the termination cap, vent may leak.
The REVO may be installed in the wall or hung on the wall. For In-Wall installations, see Section 11.
FIRESTOP
CAULK SEAMS
(4 SIDES)
APPLIANCE OUTER WRAP
CAULK
Figure 6.2. Firestop - Interior View
Figure 6.1. Firestop - Exterior View
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15 29
B. Install Appliance Corrugated Template
(On-Wall Installation)
For new construction installations in which the REVO will be mounted flush on the wall, the following preparations must be made. A Corrugated Template may be used to simplify the installation process. Contact your dealer or see Service Parts section in Owner’s manual to order.
Using the template for new construction installations of the REVO will help when locating the gas and electrical connections for the appliance. Template layout dimensions for each specific model are provided in Figures 6.5,
6.6, and 6.7.
1. Detemine the location of the appliance.
2. Hang corrugated template on studs using a permanent method such as nails, staples, tacks or screws.
3. Bring electrical and gas hookups to locations designated by markings on corrugated template.
Note: Hard-piped gas connections must be terminated with a specific “Z” dimension depth. See references to “Z” dimension in Figure 6.3. Terminating the Hard-piped gas connection with the proper “Z” dimension will simplify the process of connecting the gas to the appliance.
WARNING! Risk of overheating! Install appliance a minimum of 4 inches off of finished floor.
• Convection air flow could be compromised and cause overheating.
• Decorative fronts will not fit properly.
STUD WALL TOP VIEW
2 X 6 STUD
GAS CONNECTION
Z = 1-3 IN.
MOUNT CORRUGATED TEMPLATE
ON THIS SURFACE
WALL
GAS ACCESS ELECTRICAL ACCESS
Figure 6.3 Hard-Piped Gas Line Termination and Electrical Service
VENT
GLASS VIEWING AREA
= VENT ACCESS
= GLASS VIEWING AREA
= GAS & ELECTRICAL ACCESS
GAS ACCESS
LOCATION
4 IN. MINUMUM TO FINISHED FLOOR
ELECTRICAL
ACCESS LOCATION
Figure 6.4 Corrugated Template Layout
30 Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
REVO-V12
VENT
19-5/16 IN.
12 IN.
1-3/8 IN.
10-3/16 IN.
GLASS
VIEWING
AREA
10-3/16 IN.
24 IN.
36-1/8 IN.
3 IN.
7/16 IN.
3-7/8 IN.
2-1/4 IN.
2-3/16 IN.
2-1/4 IN.
1-1/4 IN.
3 IN.
6-3/16 IN.
7/16 IN.
3-1/2 IN.
GAS ACCESS
LOCATION
ELECTRICAL ACCESS
LOCATION
Figure 6.5 Corrugated Template Dimensions - REVO-V12
REVO-S21
VENT
28-7/16 IN.
21-1/8 IN.
1-3/8 IN.
10-3/16 IN.
10-3/16 IN.
GLASS VIEWING AREA
21-3/8 IN.
33-5/8 IN.
2-1/4 IN.
3-3/16 IN.
5-9/16 IN.
3 IN.
1-5/16 IN.
2-3/16 IN.
3-1/2 IN.
GAS ACCESS
LOCATION
ELECTRICAL ACCESS
LOCATION
Figure 6.6 Corrugated Template Dimensions - REVO-S21
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
3 IN.
6-3/16 IN.
7/16 IN.
31
REVO-H31
VENT
GLASS VIEWING AREA
10-3/16 IN.
GAS ACCESS
LOCATION
38-5/16 IN.
31 IN.
10-3/16 IN.
ELECTRICAL ACCESS
LOCATION
1-3/8 IN.
29-3/16 IN.
17 IN.
3-3/16 IN.
10-7/16 IN.
3 IN.
1-3/16 IN.
2-3/16 IN.
3-1/2 IN.
2-1/4 IN.
3 IN.
6-1/16 IN.
7/16 IN.
Figure 6.7 Corrugated Template Dimensions - H31
32 Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
C. Install Appliance Outer Wrap (On-Wall
Installation)
1. Remove the glass assembly from the firebox by releasing the two top glass latches and then the two bottom glass latches. See Figure 12.1.
2. Remove the screws that attach the firebox to the outer wrap. See Figure 6.8. Separate the firebox from the outer wrap. Carefully set the firebox aside holding it by the sides. Do not grab, lift or carry the appliance by the top heat shield, or component tray. Lay the appliance on its back to avoid damaging the component tray.
Note: Do not remove outer heat shields.
3. Position the outer wrap on the wall and ensure it is level. See Figure 6.9. A minimum of two screws must be attached to the vertical wall studs. Secure with the fasteners provided. See Figure 6.11(C) and Figure
6.12.
CAUTION! Outer wrap and appliance MUST be installed level for proper burner operation.
DO NOT REMOVE SCREW
(BOTH SIDES)
APPLIANCE TOP HEAT SHIELD
(DO NOT GRAB)
FIREBOX
4. Cut hole through wall as indicated in Figure 6.9. You may use the appliance outer wrap as a guide.
WARNING! Risk of Fire! Prevent contact with:
• Sagging or loose insulation
• Insulation backing or plastic
• Framing and other combustible materials
Block openings into the chase to prevent entry of blown-in insulation. Make sure insulation and other materials are secured.
Failure to maintain air space clearance may cause overheating and fire.
5. Frame around the edges of the firestop cut out to ensure insulation does not come into contact with the vent pipe.
See Figure 6.10 and 6.12.
6. Install wall firestop with four screws. See Figure 6.10 and Figure 6.11(C).
7. Seal the wall firestop. See Section 6.A.
OUTER HEAT SHIELDS
DO NOT REMOVE
APPLIANCE
OUTER WRAP
NOTE: The REVO-V12 has 4 screws on each side of the firebox.
Figure 6.8
Remove Firebox from Outer Wrap
COMPONENT TRAY
(DO NOT GRAB)
CUT OUT MATERIAL
FOR VENT
MATERIAL CAN BE
COMBUSTIBLE
I.E. SHEETROCK
APPLIANCE
OUTER WRAP
APPLIANCE
OUTER WRAP
FRAMING
FRAMING + SHEETROCK FRAMING + SHEETROCK
+ APPLIANCE OUTER WRAP
REMOVE CORRUGATED TEMPLATE PRIOR TO INSTALLING SHEET ROCK
OR PRIOR TO INSTALLING APPLIANCE OUTER WRAP
Figure 6.9 Install Appliance Outer Wrap
FRAMING + SHEETROCK
+ APPLIANCE OUTER WRAP + HOLE CUT
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15 33
APPLIANCE OUTER WRAP APPLIANCE OUTER WRAP
WITH FIRESTOP FRAMING
FIRESTOP
CUT OUT
FIRESTOP FRAMING
LOCATED BEHIND
OUTER WRAP AND
SHEET ROCK
FIRESTOP INSTALLED
FIRESTOP
INSTALLED
FIRESTOP INSTALLATION HOLES
Figure 6.10. Install Firestop and Firestop Framing
(A)
MASONRY
ANCHORS
(B)
SHEET ROCK
ANCHORS
WASHER (2)
ANCHOR (2)
(C)
ATTACHMENT
SCREWS (12)
ASSEMBLED
Figure 6.11 Masonry Anchors and Sheet Rock Anchors
4
8. When attaching to a brick (masonry) wall, use masonry anchors. See Figure 6.11 (A).
9. A minimum of two screws must be used to attach the appliance to vertical wall studs. See Figure 6.11 (C).
Use sheet rock anchors if a wall stud is not available on either or both sides of the appliance outer wrap.
See Figure 6.11 (B).
10. Install the firebox onto the outer wrap as directed in
Section 6.D.
11. Replace the glass assembly on the appliance. Latch the two bottom glass assembly latches and then the two top glass latches. See Figure 12.1.
12. Attach the appliance vent system. See Section 6.A for reference to sealing firestop. An SLP-TRAP2 will be needed when hanging the appliance on a 2 x 6 wall.
4
1 = FIRESTOP FRAMING HOLES SHADED
2 = FIRESTOP HOLES
3 = SHEETROCK ANCHOR HOLES
SEE FIGURE 6.11(B)
4 = VERTICAL STUD ATTACHMENT HOLES
1
NOTICE: A minimum of two screws must be attached to the vertical wall studs
4
5 = OPTIONAL ATTACHMENT HOLES
5
3
2
1
2
Figure 6.12 Outer Wrap Mounting Feature Identification
34 Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
3
5
1
4
D. Install Appliance Into Outer Wrap (On-
Wall Installation)
1. Install the firebox into the outer wrap by mating the tabs on the outer wrap with the notches located on the lower left and right bottom corners of the firebox. Do not grab, lift or carry the appliance by the top heat shield, or component tray. See Figure 6.13. The process of mating the tabs and notches accommodates the alignment of the screws with the corresponding holes. The tabs on the outer wrap should be bent outward as shown in Figure
6.13. Reinstall screws using Figure 6.8 as a reference.
DO NOT GRAB, LIFT, OR CARRY THE APPLIANCE BY THE
TOP HEAT SHIELD OR COMPONENT TRAY.
TAB
LOCATION
NOTCH
TAB BENT
OUTWARD
Figure 6.13 Install Firebox On Appliance Outer Wrap
TAB AND
NOTCH ENGAGED
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15 35
7
Venting and Chimneys
A. Assemble Vent Sections
To attach the first vent component to the starting collars of the appliance:
• Lock the vent components into place by sliding the pipe section onto the collar.
• Align the seam of the pipe and seam of collar to allow engagement. Rotate the vent component to lock into place. Use this procedure for all vent components. See
Figure 7.1.
• Slide the gasket over the first vent section and place it flush to the appliance. This will prevent cold air infiltration.
Caulk with a minimum of 300ºF continuous exposure rating may be used to hold the part in place.
• Continue adding vent components, locking each succeeding component into place.
• Ensure that each succeeding vent component is securely fitted and locked into the preceding component.
Commercial, Multi-family (Multi-level exceeding two stories), or High-Rise Applications
For Installation into a commercial, multi-family (multi-level exceeding two stories) or high-rise applications: All outer pipe joints must be sealed with high temperature silicone
(300ºF minimum continuous exposure rating), including the slip section that connects directly to the horizontal termination cap.
• Apply a bead of silicone sealant (300ºF minimum continuous exposure rating) inside the female outer pipe joint prior to joining sections. See Figure 7.2.
• Only outer pipes need to be sealed. All unit collar, pipe, slip section, elbow and cap outer flues shall be sealed in this manner, unless otherwise stated.
WARNING! Risk of Fire or Explosion! DO NOT break silicone seals on slip sections. Use care when removing termination cap from slip pipe. If slip section seals are broken during removal of the termination cap, vent may leak.
Note: Align seams to engage pipe, then rotate counterclockwise to lock
Figure 7.1 Adding Venting Components
Figure 7.2 High Temperature Silicone Sealant
36 Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
B. Installing Slip Sections
• Slide the inner flue of the slip section into the inner flue of the pipe section and the outer flue of the slip section over the outer flue of the pipe section. See Figure 7.3.
• Slide together to the desired length.
Pilot hole
Figure 7.3 Slip Section Pilot Holes
• Maintain a 1-1/2 in. (38 mm) overlap between the slip section and the pipe section.
• Secure the pipe and slip section with two screws no longer than 1/2 in. (13 mm), using the pilot holes in the slip section. See Figure 7.4
C. Secure the Vent Sections
• Vertical runs originating off the top of the appliance, with no offsets, must be supported every 8 ft. (2.44 m) after the maximum allowed 25 ft. (7.62 m) of unsupported rise.
• Vertical runs originating off the rear of the appliance, or after any elbow, must be supported every 8 ft. (2.44 m).
• Horizontal runs must be supported every 5 feet (1.52 m).
• Vent supports or plumbers strap (spaced 120º apart) may be used to support vent sections. See Figures 7.5 and 7.6.
• Wall shield firestops may be used to provide horizontal support to vent sections.
• SLP ceiling firestops have tabs that may be used to provide vertical support.
WARNING! Risk of Fire, Explosion or Asphyxiation!
Improper support may allow vent to sag and separate.
Use vent run supports and connect vent sections per installation instructions.
DO NOT allow vent to sag below connection point to appliance.
120º
Figure 7.4 Screws into Slip Section
• Continue adding pipe as necessary following instructions in “Assembling Pipe Sections.”
NOTICE: If slip section is too long, the inner and outer flues of the slip section can be cut to the desired length.
NOTICE: When installing a vent system with an HRC termination cap, all pipe system joints shall be sealed using a high temperature silicone sealant (300ºF minimum continuous exposure rating).
• Apply a bead of silicone sealant (300ºF minimum continuous exposure rating) inside the female outer pipe joint prior to joining sections.
• Only outer pipes are sealed, sealing the inner flue is not required.
• All unit collar, pipe, slip section, elbow and cap outer flues shall be sealed.
Figure 7.5 Securing Vertical Pipe Sections
120º
Figure 7.6 Securing Horizontal Pipe Sections
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15 37
D. Disassemble Vent Sections
• Rotate either section (see Figure 7.7) so the seams on both pipe sections are aligned as shown in Figure 7.8.
• Pull carefully to separate the pieces of pipe.
Figure 7.7 Rotate Seams for Disassembly
Figure 7.8 Align and Disassemble Vent Sections
38 Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
E. Vertical Termination Requirements
Install Metal Roof Flashing
• See minimum vent heights for various pitched roofs
(Figure 7.9) to determine the length of pipe to extend through the roof.
• Slide the roof flashing over the pipe sections extending through the roof as shown in Figure 7.10.
CAULK
2 FT.
MIN.
GAS DIRECT VENT
TERMINATION CAP
20 INCHES MIN.
LOWEST
DISCHARGE
OPENING
HORIZONTAL
OVERHANG
VERTICAL
WALL
12
X
ROOF PITCH
IS X/ 12
H (MIN.) - MINIMUM HEIGHT FROM ROOF
TO LOWEST DISCHARGE OPENING
Figure 7.10
Assemble and Install Storm Collar
CAUTION! Risk of Cuts, Abrasions or Flying Debris.
Wear protective gloves and safety glasses during installation. Sheet metal edges are sharp.
• Slide the storm collar onto the exposed pipe section and align brackets.
• Insert a bolt (provided) through the brackets and install nut. Do not completely tighten.
Roof Pitch H (Min.) Ft.
Flat to 6/12........................................1.0*
Over 6/12 to 7/12 ............................1.25*
Over 7/12 to 8/12 ..............................1.5*
Over 8/12 to 9/12 ..............................2.0*
Over 9/12 to 10/12 ............................2.5*
Over 10/12 to 11/12 ......................... 3.25
Over 11/12 to 12/12 ........................... 4.0
Over 12/12 to 14/12 ........................... 5.0
Over 14/12 to 16/12 ........................... 6.0
Over 16/12 to 18/12 ........................... 7.0
Over 18/12 to 20/12 ........................... 7.5
Over 20/12 to 21/12 ........................... 8.0
* 3 foot minimum in snow regions
Figure 7.9 Minimum Height From Roof To Lowest Discharge
Opening
NOTICE: Failure to properly caulk the roof flashing and pipe seams may permit entry of water.
• Caulk the gap between the roof flashing and the outside diameter of the pipe.
• Caulk the perimeter of the flashing where it contacts the roof surface. See Figure 7.10.
• Caulk the overlap seam of any exposed pipe sections that are located above the roof line.
Figure 7.11 insert Bolt into Brackets
• Slide the assembled storm collar down the pipe section until it rests on the roof flashing (see Figure 7.11).
• Tighten nut and make sure the collar is tight against the pipe section.
• Caulk around the top of the storm collar. See Figure 7.11.
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15 39
Install Vertical Termination Cap
• Attach the vertical termination cap by sliding the inner collar of the cap into the inner flue of the pipe section while placing the outer collar of the cap over the outer flue of the pipe section.
• Secure the cap by driving three self-tapping screws
(supplied) through the pilot holes in the outer collar of the cap into the outer flue of the pipe (see Figure 7.12).
Termination Cap
Storm
Collar
Caulk
Figure 7.12
40 Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
F. Horizontal Termination Requirements
Heat Shield Requirements for Horizontal
Termination
WARNING! Risk of Fire! To prevent overheating and fire, heat shields must extend through the entire wall thickness.
•
DO NOT remove the heat shields attached to the wall shield firestop and the horizontal termination cap
(shown in Figure 7.13).
• Heat shields must overlap 1-1/2 in. (38 mm) minimum.
There are two sections of the heat shield. One section is factory-attached to the wall shield firestop. The other section is factory-attached to the cap. See Figure 7.13.
If the wall thickness does not allow the required 1-1/2 in.
(38 mm) heat shield overlap when installed, an extended heat shield must be used.
• If the wall thickness is less than 4-3/8 in./ 111 mm
(SLP), the heat shields on the cap and wall shield firestop must be trimmed. A minimum 1-1/2 in. (38 mm) overlap MUST be maintained.
• Use an extended heat shield if the finished wall thickness is greater than 7-1/4 in. (184 mm).
• The extended heat shield may need to be cut to length maintaining sufficient length for a 1-1/2 in. (38 mm) overlap between heat shields.
• Attach the extended heat shield to either of the existing heat shields using the screws supplied with the extended heat shield. Refer to vent components diagrams in the back of this manual.
• Rest the small leg on the extended heat shield on top of the pipe section to properly space it from the pipe section.
Important Notice: Heat shields may not be field constructed.
Install Horizontal Termination Cap
WARNING! Risk of Fire! The telescoping flue section of the termination cap MUST be used when connecting vent.
• 1-1/2 (38 mm) minimum overlap of flue telescoping section is required.
Failure to maintain overlap may cause overheating and fire.
• Vent termination must not be recessed in the wall. Siding may be brought to the edge of the cap base.
• Flash and seal as appropriate for siding material at outside edges of cap.
• When installing a horizontal termination cap, follow the cap location guidelines as prescribed by current
ANSI Z223.1 and CAN/CGA-B149 installation codes and refer to Section 4 of this manual.
CAUTION! Risk of Burns! Local codes may require installation of a cap shield to prevent anything or anyone from touching the hot cap.
NOTICE: For certain exposures which require superior resistance to wind-driven rain penetration, a flashing kit and
HRC caps are available. When penetrating a brick wall, a brick extension kit is available for framing the brick.
Note: When using termination caps with factory-supplied heat shield attached, no additional wall shield firestop is required on the exterior side of a combustible wall.
WALL SHIELD
FIRESTOP
HEAT SHIELD OR
EXTENDED
HEAT SHIELD
OUTER WRAP
WALL
HEAT SHIELD
1-1/2 IN. (38 MM) MIN.
OVERLAP
SLIP SECTION
CAN BE EXTENDED
INTERIOR
SHEATHING
EXTERIOR
VENT DEPTH FROM BACK
OF APPLIANCE OUTER WRAP
TO OUTSIDE SURFACE
OF EXTERIOR WALL
(SEE CHART BELOW)
Figure 7.13 Venting through the wall
Termination Cap Specification Chart
(Depth without using additional pipe sections)
SLP-TRAP1 can adjust 2-3/8 in. (4-1/8 in. to 6-1/2 in.)
SLP-TRAP2 can adjust 4-1/2 in. (6-1/2 in. to 11 in)
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15 41
8
Electrical Information
A. General Information
WARNING! Risk of Shock or Explosion! DO NOT wire
110-120 VAC to the valve or to the appliance wall switch.
Incorrect wiring will damage controls.
NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with
National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
• Wire the appliance junction box to unswitched 110-
120 VAC. This is required for proper operation of the appliance.
• A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks.
• Low voltage and 110-120 VAC voltage cannot be shared within the same wall box.
Electrical Service and Repair
WARNING! Risk of Shock! Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with type 105º C rated wire. Wire must have high temperature insulation.
Junction Box Installation
If the box is being wired from the INSIDE of the appliance:
• Remove the screw attaching the junction box/receptacle.
Rotate the junction box inward to disengage it. See
Figure 8.1.
• Pull the electrical wires from outside the appliance through the opening into the valve compartment and secure wires with a Romex connector. See Figure 8.1.
• Make all necessary wire connections to the junction box/receptacle and position and secure the junction box/ receptacle into its original position.
Romex
Connector
Attach Screw
Ground
Connection
NOTICE: DO NOT wire 110-120 VAC to wall switch.
Figure 8.1 Junction Box Detail
Accessories Requirements
• This appliance may be used with a wall switch, wall mounted thermostat and/or a remote control.
Wiring for optional Hearth & Home Technologies approved accessories should be done now to avoid reconstruction.
Follow instructions that come with those accessories.
42 Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
B. Wiring Requirements
IntelliFire™ Plus
Ignition System Wiring
• Wire the appliance junction box to 110-120 VAC for proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 8.2, IPI Wiring Diagram.
• This appliance is equipped with an IntelliFire™ Plus control valve which operates on a 6 volt/1.5 AMP system.
• Plug the 6 volt transformer plug into the appliance junction box to supply power to the unit OR install 4 AA cell batteries (not included) into the battery pack before use.
NOTICE: Batteries should only be used as a power source in the event of an emergency power outage. Batteries should not be used as a primary long-term power source.
Battery polarity must be correct when installing batteries.
Do not store batteries in the battery pack when the appliance is powered by the 6 volt transformer connected to permanent electrical service.
FLAME
SENSE
IGNITER
TO JUNCTION
BOX (110V)
MODULE
FLAME
MODULATION
ORANGE
(PILOT)
GREEN
(MAIN)
BLACK
RED
GROUND
Figure 8.2 IntelliFire™ Plus Ignition (IPI) Wiring Diagram
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
RC200
BATTERY PACK
6V DC
43
9
Gas Information
A. Fuel Conversion
• Make sure the appliance is compatible with available gas types.
• Conversions must be made by a qualified service technician using Hearth & Home Technologies specified and approved parts.
B. Gas Pressure
• Optimum appliance performance requires proper input pressures.
• Gas line sizing requirements will be determined in ANSI
Z223.1 National Fuel Gas Code in the USA and CAN/
CGA B149 in Canada.
• Pressure requirements are:
Gas Pressure
Minimum inlet pressure
Maximum inlet pressure
Manifold pressure
WARNING! Risk of Fire or Explosion! High pressure will damage valve. Low pressure may cause explosion.
• Verify inlet pressures. Verify minimum pressures when other household gas appliances are operating.
• Install regulator upstream of valve if line pressure is greater than 1/2 psig.
wARNING
Note: Have the gas supply line installed in accordance with local codes, if any. If not, follow ANSI 223.1. Installation should be done by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter).
Note: A listed (and Commonwealth of Massachusetts approved) 1/2 in. (13 mm) T-handle manual shut-off valve and flexible gas connector are connected to the 1/2 in. (13 mm) control valve inlet.
• If substituting for these components, please consult local codes for compliance.
44
Natural Gas
5.0 in. w.c.
10.0 in. w.c.
3.5 in. w.c.
Propane
11.0 in. w.c.
13.0 in. w.c.
10.0 in. w.c.
Fire Risk.
Explosion Hazard.
High pressure will damage valve.
• Disconnect gas supply piping BEFORE pressure testing gas line at test pressures above 1/2 psig.
• Close the manual shutoff valve BEFORE pressure testing gas line at test pressures equal to or less than 1/2 psig.
C. Gas Connection
• Refer to Section 6 for location of gas line access in appliances installed ON the wall. Refer to Section 11 for location of gas line access in appliances installed IN the wall.
• Gas line may be run through knockout(s) provided.
• The gap between supply piping and gas access hole may be caulked with caulk with a minimum of 300ºF continuous exposure rating or stuffed with noncombustible, unfaced insulation to prevent cold air infiltration.
• Ensure that gas line does not come in contact with outer wrap of the appliance. Follow local codes.
• Pipe incoming gas line into valve compartment.
• Connect incoming gas line to the 1/2 in. (13 mm) connection on manual shutoff valve.
WARNING! Risk of Fire or Explosion! Support control when attaching pipe to prevent bending gas line.
• A small amount of air will be in the gas supply lines.
WARNING! Risk of Fire or Explosion! Gas build-up during line purge could ignite.
• Purge should be performed by qualified service technician.
• Ensure adequate ventilation.
• Ensure there are no ignition sources such as sparks or open flames.
Light the appliance. It will take a short time for air to purge from lines. When purging is complete the appliance will light and operate normally.
WARNING! Risk of Fire, Explosion or Asphyxiation!
Check all fittings and connections with a non-corrosive commercially available leak-check solution.
DO NOT use open flame. Fittings and connections could have loosened during shipping and handling.
WARNING! Risk of Fire! DO NOT change valve settings.
This valve has been preset at the factory.
D. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced, these rules do not apply. Check with your local gas utility or authorities having jurisdiction.
When installing above 2000 feet elevation:
• In the USA: Reduce input rate 4% for each 1000 feet above 2000 feet.
• In CANADA: Input ratings are certified without a reduction of input rate for elevations up to 4500 feet (1370 m) above sea level. Please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4500 feet (1370 m).
Check with your local gas utility to determine proper orifice size.
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
E. Air Shutter Setting
The Revo is shipped with an external adjustable air shutter. Air shutter settings should be adjusted by a qualified service technician at the time of installation. Adjust air shutter for maximum flame appearance. The shutter settings will vary due to fuel type and vent configuration. See
Figure 9.1.
To open the air shutter, turn the screw counterclockwise so that the screw goes in and raises the air shutter. Turning the screw clockwise will close the air shutter.
Note: The air shutter is shipped set between 3/8 in. and full open. Adjust shutter to maximize flame appearance.
NOTICE: If sooting occurs, provide more air by opening the air shutter.
SHUTTER
SLEEVE
SHUTTER
SCREW
Figure 9.1 Air Shutter
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15 45
10
Finishing (On-Wall Installation)
A. Facing and Finishing - Studio and Frame
Decorative Fronts
• Facing and/or finishing materials must not interfere with convection vents, operation of doors, or access for service. See Figure 10.1 and Figure 10.3.
WARNING! Risk of Overheating and Fire! Do not allow convection air vents to be blocked or covered. Non-combustible material must not exceed 4 inches in thickness.
• Observe all clearances when applying combustible materials.
• Remove and discard finishing strip before installing decorative front. See Figure 10.2.
• Use finishing strip to achieve required clearance. See
Figure 10.2 and 10.3.
WARNING! Risk of Fire! DO NOT apply combustible materials beyond the minimum clearances. Comply with all minimum clearances to combustibles as specified in this manual. Overlapping materials could ignite and will interfere with proper operation of doors.
DO NOT BLOCK CONVECTION VENTS
WITH FINISHING MATERIAL
FINISHING STRIP
REMOVE CLIPS
Figure 10.2 Remove Finishing Strip After Installation of Finishing
Material
Figure 10.1 Convection Vent Location
46 Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
UNBLOCKED
CONVECTION
VENTS
SHEET ROCK
WALL
SHEET ROCK
NON-COMBUSTIBLE
MATERIAL
APPLIANCE
NON-COMBUSTIBLE
MATERIAL
APPLIANCE
WALL
1/2 IN. CLEARANCE
(TOP ONLY)
*
0 IN. CLEARANCE
(BOTTOM AND SIDES)
4 IN. MAX
THICKNESS
(ALL 4 SIDES)
NOTE: MEASURE CLEARANCES
FROM APPLIANCE OUTER WRAP
*USE FINISHING STRIP TO
ACHIEVE CLEARANCE.
Figure 10.3 Non-Combustible Facing Diagram
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15 47
B. Facing and Finishing - Radius Decorative
Front (1 Inch Max. Non-Combustible)
The following instructions apply to facing and finishing materials up to one inch thick, made of non-combustible material, finished up to the appliance outer wrap and used with the Radius decorative front. For the definition of non-combustible materials, see Section 1.E.
Remove and discard finishing strip before installation of appliance. See Figure 10.4. The finishing strip is not be used with the Radius decorative front.
SHEET ROCK
FINISHING MATERIAL
NON-COMBUSTIBLE
1 IN. THICK MAX.
FINISHING STRIP
RADIUS
DOOR
ZERO CLEARANCE
(TO APPLIANCE OUTER WRAP)
ALL 4 SIDES
APPLIANCE OUTER WRAP
NOTE: The Radius front will rest an additional 1 inch from the appliance when finishing up to the appliance outer wrap.
REMOVE CLIPS
Figure 10.4 Remove Finishing Strip (Not used with Radius
Decorative Front)
DO NOT BLOCK CONVECTION VENTS
WALL
Figure 10.6 Radius Door - Side View
WALL
OUTER WRAP
NON-COMBUSTIBLE
FINISH MATERIAL
1 IN. THICK MAX.
RADIUS DOOR
SHEET ROCK
Figure 10.5 Radius Door
48
Figure 10.7 Radius Door - Non-Combustible Facing Diagram
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
ZERO CLEARANCE
TO OUTER WRAP
ALL 4 SIDES
RADIUS DOOR
Figure 10.8 Radius Door Installed - Front View
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15 49
C. Facing and Finishing - Radius Decorative
Front (4 Inch Maximum Non-Combustible)
Remove and discard finishing strip before installation of appliance. See Figure 10.4. The finishing strip is not be used with the Radius decorative front.
4 IN. MAX.
(MEASURED FROM
SHEET ROCK)
*GAP =1/2 IN.
DOOR FLUSH TO
SHEET ROCK
RADIUS DOOR
FINISHING STRIP
NON-COMBUSTIBLE
MATERIAL
4 IN. THICK MAX.
SHEET ROCK
WALL
REMOVE CLIPS
*The gap around the decorative front is needed for removing and installing the Radius decorative front.
Figure 10.11 Radius Door
Figure 10.9 Remove Finishing Strip (Not used with Radius
Decorative Front)
DO NOT BLOCK CONVECTION VENTS
WALL
*1/2 IN.
*1/2 IN.
SHEET ROCK
RADIUS DOOR *1/2 IN.
*1/2 IN.
NON-COMBUSTIBLE
FINISH MATERIAL
4 IN. THICK MAX.
NON-COMBUSTIBLE
FINISH MATERIAL
CLEARANCE TO
RADIUS DOOR
*The gap around the decorative front is needed for removing and installing the Radius decorative front.
Figure 10.10 Radius Door
50
Figure 10.12 Radius Door - Clearance to Non-Combustible
Finishing Material
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
TOP
SIDES
BOTTOM
NON-COMBUSTIBLE
FINISH MATERIAL CLEARANCE
TO APPLIANCE OUTER WRAP
V12
S21
H31
TOP SIDES BOTTOM
1-7/8 IN. 2-5/8 IN. 1-1/8 IN.
1-1/8 IN. 2-5/8 IN. 9/16 IN.
1-3/8 IN. 2-5/8 IN. 13/16 IN.
Figure 10.13 Radius Door - Clearance to Appliance Outer Wrap
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15 51
D. Mantel Projections (All Fronts)
WARNING! Risk of Fire! Comply with all minimum clearances as specified. Framing closer than the minimums listed must be constructed entirely of non-combustible materials (i.e., steel studs, concrete board, etc.).
Combustible Mantels Above Appliance Outer wrap
(All Fronts)
Note: All measurements in inches.
12 IN. MAX.
22 IN. MIN.
TO CEILING
1 IN.
MAX.
3 IN.
MAX.
6 IN. MAX.
9 IN. MIN.
12 IN. MIN.
15 IN. MIN.
18 IN. MIN.
MEASUREMENTS FROM TOP
OF APPLIANCE OUTER WRAP
APPLIANCE OUTER WRAP
SHEET ROCK
22 IN. MIN.
TO CEILING
12 IN. MAX.
9 IN. MAX.
6 IN.
MAX.
4 IN.
MAX.
12 IN. MIN.
9 IN. MIN.
6 IN. MIN.
*1/2 IN. (STUDIO & FRAME FRONT)
SEE FIGURE 10.10 FOR CLEARANCE (RADIUS FRONT)
MEASUREMENTS FROM TOP
OF APPLIANCE OUTER WRAP
APPLIANCE OUTER WRAP
SHEETROCK
*1/2 IN. GAP IS NEEDED FOR DECORATIVE FRONT
INSTALLATION AND REMOVAL.
Figure 10.15 Minimum Vertical and Maximum Horizontal
Dimensions of Non-Combustibles
Figure 10.14 Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles
Non-Combustible Mantels Above Appliance
Outer Wrap (All Fronts)
Note: All measurements in inches.
52 Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
E. Mantel Leg and Wall Projections
The mantel leg and wall projection dimensions are determined by the decorative front that is to be installed.
Studio and Frame decorative fronts are referenced on the left side of this page. Radius decorative fronts are referenced on the right side of the page. Note the figure titles in regards to whether the mantel/wall projection is made from combustible or non-combustible material.
Combustible Mantel Legs or Wall Projections
(Studio and Frame Fronts)
MOUNTED FLUSH WITH WALL
DRYWALL
TOP OF
1/4 IN.
APPLIANCE
OUTER WRAP
4 IN.
UNLIMITED
12 IN.
(305 MM)
MIN.
MANTEL LEG OR
PERPENDICULAR WALL
(STUDIO AND FRAME DOORS ONLY)
Figure 10.16 Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of outer wrap)
Non-Combustible Mantel Legs or Wall Projections
(Studio and Frame Fronts)
MOUNTED FLUSH WITH WALL
DRYWALL
4 IN.
TOP OF APPLIANCE
OUTER WRAP
UNLIMITED
6 IN.
MIN.
MANTEL LEG OR
PERPENDICULAR WALL
(STUDIO AND FRAME DOORS ONLY)
Figure 10.17 Non-Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of outer wrap)
Combustible Mantel Legs or Wall Projections
(Radius Fronts)
TOP OF
APPLIANCE
MOUNTED FLUSH WITH WALL
1/2 IN.
SHEET
ROCK
4 IN.
2-5/8
IN.
UNLIMITED
RADIUS DECORATIVE
FRONT (DASHED LINE)
12 IN.
MANTEL LEG OR
PERPENDICULAR WALL
(RADIUS DOORS ONLY)
Figure 10.18 Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of outer wrap)
Non-Combustible Mantel Legs or Wall Projections
(Radius Fronts)
1 IN.
MOUNTED FLUSH WITH WALL
ZERO CLEARANCE
1 IN.
DRYWALL
TOP OF
APPLIANCE
4 IN.
1/2 IN.
UNLIMITED
2-5/8 IN.
RADIUS DECORATIVE
FRONT(DASHED LINE)
6 IN.
MANTEL LEG OR
PERPENDICULAR WALL
(RADIUS DOORS ONLY)
Figure 10.19 Non-Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of outer wrap)
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15 53
11
In-Wall Installation
The Revo may be installed recessed into the wall using the In-Wall Tub. The Frame and Studio doors are compatible with this type of installation. In-Wall installation is not compatible with the Radius decorative front.
A. wall and Appliance Preparation
WARNING! Risk of Fire! Comply with all minimum clearances as specified. Framing closer than the minimums listed must be constructed entirely of noncombustible materials
(i.e., steel studs, concrete board, etc.)
NOTICE: The In-Wall application is not compatible with the Radius decorative front.
1. Prepare 2 in. x 6 in. framing as shown in Figure 11.1.
Note: 2 X 4 framing is not recommended in geographical regions that require an R-19 insulation value.
2. A Corrugated Template may be used to simplify the installation process. Contact your dealer or see Service
Parts section in Owner’s manual to order. Using the template for installations of the REVO will help when locating the gas and electrical connections for the appliance. Install the corrugated template as shown in
Figure 11.2. Use blocks to position the corrugated template in regards to depth.
3. Bring electrical and gas hookups to location designated by markings on corrugated template. Remove template and blocks when utility installation is complete.
Note: Hard-piped gas connections must be terminated with a specific “Z” dimension depth. See references to “Z” dimension in Figure 11.2. Terminating the Hard-piped gas connection with the proper “Z” dimension will simplify the process of connecting the gas to the appliance.
FRAMING
DIMENSIONS
V12
S21
H31
A
20-1/8 in.
29-3/8 in.
39-3/8 in.
B
43-1/8 in.
40-1/2 in.
39 in.
C
4 in. min.
4 in. min.
4 in. min.
IN-WALL TUB CLEARANCES
WALL - FRAMED
SEE DIMENSION B
FOR CLEARANCE
(TOP)
ZERO
CLEARANCE
(BACK)
FINISHED
FLOOR
C=4 IN. MIN.
A
B
OPTIONAL
FINISHING
STRIPS
SEE DIMENSION A
FOR CLEARANCE
(SIDE)
ZERO
CLEARANCE
(BOTTOM)
Figure 11.1 Framing Dimensions and In-Wall Tub - Clearances
54 Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
CORRUGATED
TEMPLATE INSTALLED
NOTE: USE BLOCKS TO ACHIEVE
2 INCH DEPTH FOR POSITION OF
CORRUGATED TEMPLATE.
TOP VIEW
BLOCKS
TEMPLATE
(DASHED LINES)
Z DIMENSION =OPTIMAL
HARD-PIPED GAS DEPTH 1-3 IN.
Z=1-3 IN.
HARD-PIPED GAS
CONNECTION
TERMINATION
2 IN.
VERTICAL STUDS
GAS
ACCESS
ELECTRICAL
ACCESS
GAS ACCESS ELECTRICAL ACCESS
CORRUGATED TEMPLATE FLUSH WITH BOTTOM STUD AND
CENTERED LEFT TO RIGHT BETWEEN VERTICAL STUDS
Figure 11.2 In-Wall with Corrugated Template
BOTTOM STUD
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15 55
A
B
C
INSTALL HERE
INSULATION
INSTALLED
CORRUGATED
TEMPLATE
FINISHED
FLOOR
D
SCREWS
NOTE: INSTALL
SCREWS
SCREWS
E
GAS
ACCESS
NON-COMBUSTIBLE
BOARD INSTALLED
(6 SCREWS)
ELECTRICAL
ACCESS
F
NOTE: REMOVE CORRUGATED TEMPLATE
BEFORE INSTALLING INSULATION
NON-COMBUSTIBLE
BOARD
HOLES FOR
ATTACHING
OUTER WRAP
TUB ASSEMBLY
INSTALLED
SCREWS
FINISHED
FLOOR
G
H
REMOVE TOP FINISHING STRIP FROM APPLIANCE BEFORE INSTALLING IN TUB.
SEE FIGURE 11.9.
I
NON-COMBUSTIBLE
BOARD
NON-COMBUSTIBLE
BOARD
OUTER WRAP
INSTALLED
FIRESTOP/
OUTER WRAP
INSTALLED
NON-COMBUSTIBLE
BOARD
APPLIANCE
INSTALLED
4 IN. TO
FINISHED
FLOOR
Figure 11.3. In-Wall Tub Installation
56 Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
4. Insulate wall per local code requirements. Use Thermax where an R19 insulation value is required.
See Figure 11.3 (C) and Figure 11.6.
5. Install In-Wall Tub as shown in Figure 11.3 (D). The tub should set on the framing. Verify hood clips are in the correct orientation. See Figure 11.5. Ensure tub is level. Use eight screws (supplied with In-Wall Kit) to attach the tub to the framing.
CAUTION! In-Wall Tub and Appliance Outer Wrap
MUST be installed level for proper burner operation.
6. Install the required non-combustible board (supplied) as shown in Figure 11.3 (E) using six screws.
WARNING! Risk of Fire! DO NOT apply combustible materials beyond the minimum clearances. Comply with all minimum clearances to combustibles as specified in this instruction. Overlapping materials could ignite and will interfere with doors.
7. Cut through insulation and wall as shown in Figure
11.3(E). Allow space for clearance for the firestop framing disussed in step 11.
8. Remove the glass assembly from the firebox by releasing the two top glass latches and then the two bottom glass latches. See Figure 12.1.
9. Remove firebox from outer wrap. See Figure 6.8.
10. Install the outer wrap as shown in Figure 3 (F & G) using the four supplied bolts in the threaded holes.
Additional screws may be installed to ensure the tub
CAP EXTENSION
CAULK
PERIMETER
(EDGE)
SLP-TRAP1 CAP
and the outer wrap are secured flat to one another.
11. Frame around the edges of the firestop cut out to ensure insulation does not come into contact with the vent pipe. See Figure 6.10 and 6.12.
12. Install firestop using the four supplied screws. See
Figure 6.10 and 6.11. See Section 6.A for reference to sealing firestop.
13. Install finishing strips if applicable. See Figure 11.5.
14. Reattach firebox to outer wrap. Use Figure 6.8 and
6.13 for reference.
15. Replace the glass assembly on the appliance. Latch the two bottom glass assembly latches and then the two top glass latches. See Figure 12.1.
16. Attach the appliance vent system. See Section 6.A for reference to sealing firestop.
NOTICE! Install a cap extension if gap exists between the wall and the back of the termination cap. See Figure
11.4. An SLP-TRAP1 will generally be used with In-Wall installations.
17. Install vent and trap cap extension if a gap exists between the exterior wall and the cap. To prevent drafts, the cap extension should be sealed with caulk that has a minimum of 300ºF continuous exposure rating to seal gaps of the extension. See Figure 11.4.
NO
EXTENSION
CAULK
PERIMETER
GAP
CAP
EXTENSION
INSTALLED
TO ELIMINATE
GAP
2 X 6 WALL
CAP EXTENSION INSTALLED
Figure 11.4 Cap Extension Installation
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15 57
18. Have a qualified service technician make the connections to gas and electric service.
WARNING! Risk of Fire or Explosion! Gas and electric connections should be performed by a qualified service technician.
19. Gas line holes and other openings should be caulked or sealed.
(VIEW SHOWN WITH
FINISHING STRIPS)
HOOD CLIP DETAIL
FINISHING STRIPS
B. In-Wall - Minimum Combustible Facing
Clearances
NOTICE: The In-Wall application is not compatible with the Radius decorative front.
V12
S21
H31
A
20-1/8 in.
29-3/8 in.
39-3/8 in.
WALL - FRAMED AND SHEETROCKED
D
43-7/8 in.
41-1/4 in.
39-3/4 in.
1-1/2 IN.
NON-COMBUSTIBLE
BOARD
A
D
*3/4 IN. MIN.
TOP
SHEET ROCK
1/2 INCH MAX.
THICKNESS
* = 3/4 IN. OF STUD IS
EXPOSED FOR
MOUNTING 1/2 INCH
NON-COMBUSTIBLE
BOARD
NON-COMBUSTIBLE
BOARD
FINISHED FLOOR
C =4 IN. MIN.
PROPER INSTALLATION OF HOOD CLIPS
(VIEW SHOWN WITHOUT FINISHING STRIPS)
Figure 11.5 Finishing Strip Attachment & Proper Hood Clip
Installation
TOP VIEW
VERTICAL
2 X 6 STUDS
2 X 6 HEADER
Figure 11.7. In-Wall Tub Installation - Sheet Rock Facing
TUB ASSEMBLY
BEFORE
AFTER
TOP VIEW WITH
TUB INSTALLED
INSULATION ZONE
2 IN.
TUB ASSEMBLY
3-1/2 IN.
1/2 IN. MAX.
THICKNESS
Figure 11.6. In-Wall Tub Installation - Top View
58
Figure 11.8. In-Wall Tub Installation - Sheet Rock Thickness
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
C. In-Wall - Minimum Non-Combustible
Facing Clearances
NOTICE: The In-Wall application is not compatible with the Radius decorative front.
NON-COMBUSTIBLE FACING
NON-COMBUSTIBLE BOARD
FINISHING
STRIPS
APPLIANCE FINISHING STRIP
SHEET ROCK
1/2 IN. MAX.
THICKNESS
REMOVE CLIPS
1-1/2 IN. MAX.
THICKNESS
REMOVE APPLIANCE FINISHING STRIP
NOT USED WITH IN-WALL KIT
ZERO CLEARANCE TO
IN-WALL TUB OPENING
(TOP, BOTTOM AND SIDES)
NOTE: FINISHING STRIPS CAN BE USED TO
MAINTAIN PROPER CLEARANCE.
SEE FIGURE 11.5 FOR INSTALLATION.
Figure 11.9
STUDIO OR FRAME DECORATIVE FRONT
NON-COMBUSTIBLE FACING
NON-COMBUSTIBLE BOARD
1-1/2 IN.
THICK MAX.
DO NOT BLOCK
CONVECTION VENTS
NOTE: FINISHING STRIPS CAN BE USED TO
MAINTAIN PROPER CLEARANCE.
SEE FIGURE 11.5 FOR INSTALLATION.
Figure 11.10
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
SHEET ROCK
STUDIO OR FRAME
DECORATIVE FRONT
59
D. In-Wall Mantel and Wall Projections
Combustible Mantel Legs or Wall Projections
IN-WALL TUB MOUNT
TOP VIEW
1/2 IN.
MAX.
VERTICAL FRAMING STUDS
1/2 IN.
SHEETROCK/COMBUSTIBLE
FACING MATERIAL
TUB
APPLIANCE
OUTER WRAP
0 IN.
FROM
IN-WALL
TUB OPENING
UNLIMITED
1-1/2 IN. FROM
SHEETROCK/COMBUSTIBLE
FACING MATERIAL
12 IN.
FROM
IN-WALL
TUB
OPENING
MANTEL LEG OR
PERPENDICULAR WALL
Combustible Mantels Above Appliance Outer wrap
Note: All measurements in inches.
3 IN. MAX.
6 IN. MAX.
15 IN. MIN.
18 IN. MIN.
22 IN. MIN
TO CEILING
Figure 11.11 Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
MEASUREMENTS FROM TOP
OF APPLIANCE OUTER WRAP
APPLIANCE OUTER WRAP
SHEETROCK 1/2 IN. MAX. THICKNESS
IN-WALL TUB AND APPLIANCE
BEHIND SHEETROCK/COMBUSTIBLE FACING MATERIAL
Non-Combustible Mantel Legs or Wall Projections
IN-WALL TUB MOUNT
TOP VIEW
VERTICAL FRAMING STUDS
1-1/2 IN. FROM
SHEETROCK/COMBUSTIBLE
FACING MATERIAL
TUB
APPLIANCE
OUTER WRAP
SHEETROCK/COMBUSTIBLE
FACING MATERIAL
1/2 IN. MAX.
= 6 IN. MIN.
FROM IN-WALL
TUB OPENING
UNLIMITED
= 0 IN. MIN.
FROM IN-WALL TUB OPENING
MANTEL LEG OR
PERPENDICULAR WALL
Figure 11.13 Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles
Non-Combustible Mantels Above Appliance
Outer wrap
9 IN. MAX.
22 IN. MIN.
TO CEILING
Figure 11.12 Non-Combustible Mantel Leg or Wall Projections
60
(Acceptable on both sides of opening)
IN-WALL TUB
AND APPLIANCE
BEHIND SHEETROCK/
COMBUSTIBLE
FACING MATERIAL
1-1/2
IN.
6 IN. MAX.
3 IN.
MAX.
6 IN. MIN.
12 IN. MIN.
9 IN. MIN.
1/2 IN. MIN. OR FLUSH WITH
IN-WALL TUB OPENING
MEASUREMENTS FROM TOP
OF APPLIANCE OUTER WRAP
APPLIANCE OUTER WRAP
SHEETROCK 1/2 IN. MAX. THICKNESS
1/2 IN. MAX.
Figure 11.14 Minimum Vertical and Maximum Horizontal
Dimensions of Non-Combustibles
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
E. In Wall - Finishing
The splatter guard is a piece of corrugated material used to protect the appliance during the installation process before finishing work on the whole hearth is complete. The splatter guard is shipped with the In-
Wall Kit on the REVO models. Splatter guards must be removed before appliance is fired.
WARNING! Risk of Fire! Close the ball valve before installing the splatter guard to prevent accidental lighting.
Remove the splatter guard before lighting the appliance.
SPACE
SLOTS
CREASE LOCATION
Figure 11.16 Splatter Guard Installed
Figure 11.15 Splatter Guard Installation
1. Install the splatter guard in the space between the tub and the top and sides of the appliance outer wrap.
See Figure 11.15.
2. To gain access to the component tray, lift the flap on the splatter guard and crease the perforation by hand.
Bend the tabs and insert them into the slots on the splatter guard. See Figures 11.16 and 11.17.
TABS INSERTED INTO SLOTS
COMPONENT
TRAY ACCESS
PANEL
Figure 11.17 Component Tray Access
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15 61
12
Appliance Setup
A. Removing Fixed Glass Assembly
WARNING! Risk of Asphyxiation! Handle fixed glass assembly with care. Inspect the gasket to ensure it is undamaged and inspect the glass for cracks, chips or scratches.
• DO NOT strike, slam or scratch glass.
•
DO NOT operate fireplace with glass removed, cracked,
broken or scratched.
• Replace as a complete assembly.
Removing Fixed Glass Assembly
• Remove the glass assembly from the firebox by releasing the two top glass latches and then the two bottom glass latches. Hold glass in place with one hand and disengage glass latches with the other hand. Remove glass assembly from the appliance. See Figure 12.1.
Remove the glass shipping brackets by removing the two screws on each bracket. Discard glass shipping brackets.
See Figure 12.2.
Replacing Fixed Glass Assembly
• Place the glass assembly on the appliance. Latch the two bottom glass assembly latches and then the two top glass latches. Hold glass in place with one hand and secure glass latches with the other hand. See Figure
12.1.
GLASS LATCHES
(BOTH TOP AND BOTTOM)
GLASS SHIPPING BRACKETS
(DISCARD)
GLASS ASSEMBLY
Figure 12.2 Remove Shipping Brackets
C. Clean the Appliance
Clean/vacuum any sawdust that may have accumulated inside the firebox or underneath in the control cavity.
Figure 12.1 Fixed Glass Assembly
B. Remove the Shipping Materials
Remove shipping materials from inside or underneath the firebox. If an In-Wall kit has been purchased, a splatter guard will be included. The splatter guard is a piece of corrugated material used to protect the appliance during the installation process before finishing work on the whole hearth is complete. Splatter guards must be removed before appliance is fired. See Section 11.E for more information on installation of the splatter guard.
WARNING! Risk of Fire! Close the ball valve before installing the splatter guard to prevent accidental lighting.
Remove the splatter guard before lighting the appliance.
62
D. Decorative Fronts/Mesh
The decorative fronts designed for this appliance include a mesh screen. Installation of the decorative front/mesh screen assembly is required for operation of this appliance. For installation instructions, see the instructions included with the decorative front.
WARNING! Risk of Fire! Install ONLY doors or fronts approved by Hearth & Home Technologies. Unapproved doors or fronts may cause fireplace to overheat.
This fireplace has been supplied with an integral barrier to prevent direct contact with the fixed glass panel. DO NOT operate the fireplace with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one.
For more information refer to the instructions supplied with the decorative front.
NOTICE: The In-Wall application is not compatible with the Radius decorative front.
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
13
Reference Materials
A. Vent Components Diagrams
6-1/2 in.
165 mm
6-1/2 in.
165 mm
8-3/4 in.
222 mm
6 in.
152 mm
6-1/2 in.
165 mm
Effective
Height/
Length
SLP PIPE
6-5/8 in.
168 mm
SLP45
45° Elbow
Effective Height/Length
Pipe
inches mm
SLP4 4 102
SLP6
SLP12
SLP24
SLP36
SLP48
SLP6A
SLP12A
SLP-FLEX-2
SLP-FLEX-3
SLP-FLEX-5
SLP-FLEX-10
6
12
24
36
48
2 - 6
2 - 12
24
36
60
120
152
305
610
914
1219
51 - 152
51 - 305
610
914
1524
3048
6-5/8 in.
168 mm
9-7/8 in.
251 mm
SLP90
90° Elbow
10-7/8 in.
276 mm
8-7/8 in.
225 mm
SLP-HVS
Horizontal Pipe
Support
9-1/4 in.
235 mm
1-1/2 in.
38 mm
8-11/16 in.
220 mm
12 in.
305 mm
8-11/16 in.
220 mm
SLP-FS
Ceiling Firestop
Figure 13.1 SLP Vent Components
1-1/2 in.
38 mm
12 in.
305 mm
SLP-WS
Wall Shield Firestop
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
Figure 16.6 Vent Components
5-1/2 in.
146 mm
63
A. Vent Components Diagrams (continued)
15-1/8 in.
(384 mm)
Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm) the existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a
DVP-HSM-B will be required.
8 in.
(203 mm)
Heat
Shield
12 in.
(305 mm)
SLP-TRAP
Horizontal Termination Cap
Max
Effective
Length
Term Cap
Trap1
Trap2
Minimum
Effective Length
3-1/8 in.
79 mm
5-1/4 in.
133 mm
Maximum
Effective Length
4-3/4 in.
121 mm
9-1/4 in.
235 mm
3-15/16 in.
(101 mm)
6-11/16 in.
(169 mm)
3-13/16 in.
(97 mm)
8 in.
(203 mm)
SL-2DVP
Adapter
3-15/16 in.
(101 mm)
5-1/16 in.
(128 mm)
26 in.
660 mm
DVP-HSM-B
Extended Heat Shield
14-7/16 in.
367 mm
14-7/16 in.
367 mm
2-5/16 in.
59 mm
SLP-WT-BK
Wall Thimble-Black
64
Figure 13.2 SLP vent components
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
A. Vent Components Diagrams (continued)
12 in.
305 mm
14 in.
356 mm
10-9/16 in.
269 mm
SLP-CCS-BK
Cathedral Ceiling
Support Box-Black
SLP-TVHW
Vertical
Termination Cap
12-1/2 in.
318 mm
14-1/16 in.
357 mm
14 in.
356 mm
7-1/2 in.
192 mm
10-3/4 in.
273 mm
SLP-FLEX-TRAP
Horizontal
Termination Kit
13 in.
330 mm
13 in.
330 mm
SLP-DCF-BK
Ceiling Firestop
Black
1-5/16 in.
34 mm
7-3/8 IN.
187 mm
17-7/8 IN.
454 mm
14 IN.
356 mm
12 IN.
305 mm
SLP-TB1
Basement Vent Cap
10-11/16 in.
271mm
1 in.
(25 mm)
7-1/4 in.
(184 mm)
28-1/2 in.
724 mm
14 in.
(356 mm)
13-1/2 in.
343 mm
3/8 in. (10 mm)
1 in. (25 mm)
SLK-SNKD
Snorkel
Termination Cap
Figure 13.3 SLP vent components
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
7-3/4 to 10-3/8 in.
(197 to 264 mm)
DVP-FBHT
Horizontal
Termination Cap
65
A. Vent Components Diagrams (continued)
Note: Vent runs including the PVK-80 or
PVI-SLP may not exceed 30 feet in total vent length or six 90 degree elbows.
EFFECTIVE LENGTH
32 IN. (813 mm) MIN.
35 IN. (889 mm) MAX.
PVI-SLP
Power Vent Inline
20-3/4 IN.
527 mm
13-5/8 IN.
346 mm
12-1/2 IN.
318 mm
Optional wire Harness
DESCRIPTION PART NUMBER
10 FT PV Wire Harness PVI-WH10
20 FT PV Wire Harness PVI-WH20
40 FT PV Wire Harness PVI-WH40
60 FT PV Wire Harness PVI-WH60
80 FT PV Wire Harness PVI-WH80
100 FT PV Wire Harness PVI-WH100
Note: Wire harnesses required to power the PVI-SLP connect to the appliance and are ordered separately from
PVI-SLP. Contact your dealer to order.
Note: Use only approved termination caps with the PVI-
SLP. See instructions included with PVI-SLP kit.
2-3/4 in.
(70 mm)
9 in.
(229 mm)
12-1/2 in.
(318 mm)
11-1/2 in.
(292 mm)
12-1/4 in.
(311 mm)
16 in.
(406 mm)
PVK-80
(Not approved for use with REVO-V12.)
66
Figure 13.4 SLP vent components
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
A. Vent Components Diagrams (continued)
8-1/8 in.
(206 mm)
13 in.
(330 mm)
15 in.
(381 mm)
Effective Length
5-3/4 to 8-3/8 in.
146 to 213 mm
5-1/2 in.
140 mm
87°
3°
8-3/8 in.
213 mm
10-1/2 in.
267 mm
10-7/8 in.
276 mm
wARNING
Fire Risk.
• When using DVP-HRC-SS or DVP-HRC-ZC-SS termination caps on top vented fireplaces, a 6 inch minimum vertical vent section is required before installing first elbow.
COAXIAL to COLINEAR VENTING
DVP-HRC-SS
DVP-HRC-ZC-SS
HORIZONTAL TERMINATION CAP
LINK-DV30B
Flex Liner Kit
768-380A
Stainless Steel Flex Pipe
DV-46DVA-GCL
Coaxial/Colinear Appliance Connector
DVP-2SL
Adapter
Figure 13.5 DVP vent components
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15 67
A. Vent Components Diagrams (continued)
PVLP-SLP
(Not approved for use with REVO-V12)
Top View
6-1/4 IN.
159 mm
1-1/2 IN.
38 mm
Side View Front View
15-1/2 IN.
394 mm
2-1/4 IN.
57 mm
14 IN.
356 mm
11-1/2 IN.
292 mm
Required wire Harness
DESCRIPTION PART NUMBER
10 FT PV Wire Harness
20 FT PV Wire Harness
40 FT PV Wire Harness
PVI-WH10
PVI-WH20
PVI-WH40
60 FT PV Wire Harness
80 FT PV Wire Harness
PVI-WH60
PVI-WH80
100 FT PV Wire Harness PVI-WH100
8 IN.
203 mm
4-3/4 IN.
121 mm
9-1/2 IN.
241 mm
5-1/4 IN.
135 mm
4-3/8 IN.
112 mm
10 IN.
254 mm
2-1/4 IN.
57 mm
Note: Wire harnesses required to power the PVLP-SLP connect to the appliance and are ordered separately from
PVLP-SLP. Contact your dealer to order.
Note: The PVLP-SLP requires a PVLP-CK be installed on this appliance. The PVLP-CK is ordered separately from the PVLP-SLP. Contact your dealer to order.
Note: A PVLP-HS heat shield is available and sold separately.
Use if the PVLP-SLP is installed in a high traffic area.
PVLP-BEK
Brick Kit
PVLP-HS
Heat Shield
68
Figure 13.6 PVLP-SLP Vent Components
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
B. Accessories
Remote Controls, wall Controls and wall
Switches
Follow the instructions supplied with the control installed to operate your fireplace:
For safety:
• Install a switch lock or a wall/remote control with child protection lockout feature.
• Keep remote controls out of reach of children.
See your dealer if you have questions.
Heat & Glo, a brand of Hearth & Home Technologies
7571 215 th
Street West, Lakeville, MN 55044 www.heatnglo.com
Please contact your Heat & Glo dealer with any questions or concerns.
For the location of your nearest Heat & Glo dealer, please visit www.heatnglo.com.
Printed in U.S.A. - Copyright 2015
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15 69
advertisement
Key Features
- Direct Vent
- On-Wall and In-Wall Installation
- Natural Gas and Propane Compatible
- Supplemental Room Heat
- Decorative Appliance
- Safety Features
- UL Listed
Frequently Answers and Questions
What types of gas can the REVO series fireplaces be used with?
Can the REVO series fireplaces be used as a primary heat source?
What are the minimum clearances required for the REVO series fireplaces?
Related manuals
advertisement
Table of contents
- 3 Installation Standard Work Checklist
- 4 A. Appliance Certification
- 4 B. Glass Specifications
- 4 C. BTU Specifications
- 4 D. High Altitude Installations
- 4 E. Non-Combustible Materials Specification
- 4 F. Combustible Materials Specification
- 4 G. Electrical Codes
- 5 H. Requirements for the Commonwealth of Massachusetts
- 6 A. Design and Installation Considerations
- 6 B. Tools and Supplies Needed
- 6 C. Inspect Appliance and Components
- 7 D. Installation Methods:On-Wall or In-Wall
- 8 A. Appliance/Decorative Front Dimension Diagrams
- 12 B. Clearance to Combustibles
- 13 C. Constructing the Appliance Chase
- 13 D. Floor Protection
- 14 E. Clearances (On-Wall and In-Wall)
- 15 Back of Appliance
- 16 A. Vent Termination Minimum Clearances
- 17 B. Chimney Diagram
- 18 C. Approved Pipe
- 18 D. Use of Elbows
- 19 E. Measuring Standards
- 19 F. Vent Diagrams
- 27 A. Pipe Clearances to Combustibles
- 27 B. Wall Penetration Framing/Firestops
- 28 C. Ceiling Firestop/Floor Penetration Framing
- 28 D. Install Attic Insulation Shield
- 29 A. Vent Collar Preparation - Sealing the Firestop
- 30 (On-Wall Installation)
- 33 C. Install Appliance Outer Wrap (On-Wall Installation)
- 35 D. Install Appliance Into Outer Wrap (On-Wall Installation)
- 36 A. Assemble Vent Sections
- 37 B. Installing Slip Sections
- 37 C. Secure the Vent Sections
- 38 D. Disassemble Vent Sections
- 39 E. Vertical Termination Requirements
- 41 F. Horizontal Termination Requirements
- 42 A. General Information
- 43 B. Wiring Requirements
- 44 A. Fuel Conversion
- 44 B. Gas Pressure
- 44 C. Gas Connection
- 44 D. High Altitude Installations
- 45 E. Air Shutter Setting
- 46 Decorative Fronts
- 48 (1 Inch Max. Non-Combustible)
- 50 (4 Inch Maximum Non-Combustible)
- 52 D. Mantel Projections (All Fronts)
- 53 E. Mantel Leg and Wall Projections
- 54 A. Wall and Appliance Preparation
- 58 B. In-Wall - Minimum Combustible Facing Clearances
- 60 D. In-Wall Mantel and Wall Projections
- 61 E. In Wall - Finishing
- 62 A. Removing Fixed Glass Assembly
- 62 B. Remove the Shipping Materials
- 62 C. Clean the Appliance
- 62 D. Decorative Fronts/Mesh
- 63 A. Vent Components Diagrams
- 69 B. Accessories