Generators & Transfer Switches
Generators & Transfer Switches
Product Catalog
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
2
About Milbank
Energy at Work
Milbank builds solutions that move power for the residential, commercial, industrial, utility
and transportation sectors. Milbank combines more than 85 years of expertise in electrical
engineering design and manufacturing with a commitment to develop and globally implement
sustainable, integrated power solutions. Milbank’s portfolio includes electric metering
systems, enclosed controls, and power generation and energy management solutions. A thirdgeneration, family-owned business, Milbank is headquartered in Kansas City, Mo.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
Table of Contents
3
Generators & Transfer Switches Product Catalog
Standby Generator Systems
Home Standby Generators
Commercial Standby Generators
Industrial Standby Generators
4-9
10-17
18-19
Transfer Switches
SynapSwitch™ Automatic Transfer Switches
Vigilant® Automatic Transfer Switches
Manual Transfer Switches
22
23
24-25
Digital Inverter Generators
1000 & 1800W
26
Portable Generators
3250 - 10,000W
27
Enclosed Controls
Features & Applications
CP3B “Power Transfer” Series
28
29
Contractor & Distributor Benefits
Milbank Authorized Generator Technician Certification
Milbank OneSERT
Technical Specifications
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
30
31
32-51
4
8 & 10kW
Home Standby Generators
MODELS
8kW1 | MG08001
Keep essential appliances powered with the 8kW1 generator
connected to pre-selected circuits.
10kW1 | MG10002
Power the essentials and more with the 10kW1 paired with
Milbank’s automatic transfer switch. Utilizing our Power
Management Technology, the automatic transfer switch
allows for flexible management of electricity and appliances
- all while using a smaller, more fuel-efficient generator.
FEATURES
More Power in a Smaller Generator – The compact 81
and 10kW1 standby generator is one of the most powerful
units of its kW class with higher power output per square
inch of its footprint – providing backup electricity to more
of your household appliances.
Homeowner Safety & Protection – We take protection
to a whole new level - the 8kW1 and 10kW1 come with
an external, automatic gas shut-off valve, low pressure
regulator and a thermally-protected fuel system which
automatically shuts down the unit during an emergency
(not found on any other competing generator in its class).
Comprehensive Warranty – Both the 8kW1 and 10kW1
units include a three-year, comprehensive parts and labor
warranty2. At Milbank, we stand behind our products (for
more than 85 years!), making it easy for our customers to
work with us.
Flexible Placement3 – Tested against the tough National
Fire Protection Agency 37 standard, Milbank 81 & 10kW1
standby generators can be placed as close as 18” from
the home providing more placement options in your
yard– perfect for tight lot lines.
Durable Enclosure & Base – Our enclosures are made
from the same rust-resistant, durable Galvanneal steel
that is found in the automotive industry and features an
automotive-grade paint process which results in protection
against chipping and abrasions. Our enclosures and base
can endure temperatures of more than double that of
aluminum and plastic.
Innovative Airflow Technology – With the engine and
alternator intakes located in the rear, front ventilation
pushes the heat and carbon monoxide away from the
house - protecting homes, shrubs and landscaping from
damage.
Low Pressure, No Problem - No need to worry if you live
in an area with low gas pressure. Milbank generators are
rated for 5” to 7” water column but can be as low as 3.5”
with proper accommodations.
Easy Wireless Monitoring - Simple, trouble-free
monitoring is a reality with our optional Basic Wireless
Monitor (sold separately).
3
YEAR
WARRANTY
1
This generator is rated in accordance with UL (Underwriters Laboratories) 2200 (stationary engine generator assemblies) and CSA (Canadian Standards Association)
standard C22.2 No. 100-04 (motors and generators). 2Warranty details are available at milbankworks.com. 3Installations must strictly comply with all applicable codes, industry standards, laws, regulations and provided installation manual. Running engines give off carbon monoxide, an odorless, colorless, poisonous gas so it is important
to keep exhaust gas away from any windows, doors, ventilation intakes or crawl spaces. The installation manual contains specific instructions related to generator placement in addition to NFPA 37, including the requirement that carbon monoxide detectors be installed and maintained in your home. Milbank reserves the right to make
changes in specifications and features shown without notice or discontinue the product described at any time without notice or obligation. Other Generator/Automatic
Transfer switch manufacturers’ products are not compatible with Milbank Home Generator Systems.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
5
8 & 10kW
Home Standby Accessories
MAINTENANCE KIT
Complete with special UL air filter, pre-cleaner,
spark plugs, oil filter, and synthetic oil.
8kW | MG080022
10kW | MG101222
WIRELESS MONITOR
MG626401
Easy, trouble-free monitoring is a reality with the new
Milbank Basic Wireless Monitor. Place the wireless monitor
in your home and know your generator is working without
ever having to go outside.
COLD WEATHER KIT
8kW | MG626201 - Dual Oil Heater
Complete with a dual oil heater and battery warmer - both
thermostatically controlled to heat up when the temperature
drops, ensuring smooth starting and engine operation.
Tested at -25ºF.
10kW | MG111102
Complete with an oil heater and battery warmer - both
thermostatically controlled to heat up when the temperature
drops, ensuring smooth starting and engine operation.
Tested at -25ºF.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
WIRELESS ROUTER
MG623501
A signal enhancement to
overcome obstructions.
Recommended for applications with distances of
100 feet or more.
6
12kW
Home Standby Generators
MODELS
12kW1 | MG12003
Bigger isn’t always better - especially when it comes to
whole-house power. Ideal for small- to medium-sized
homes, the 12kW1 generator can intuitively power the
whole house when paired with a Milbank automatic
transfer switch.
FEATURES
Premium Vanguard™ Engine – You asked, we answered.
And brought the Briggs & Stratton commercial grade
Vanguard™ engine back to Milbank’s 12kW¹ generator.
Vanguard™ engines are designed and engineered to
provide long-lasting, reliable power.
Minimal Footprint – Its streamlined, compact design
offers the smallest footprint among the competition in
the 12kW size range (18.1ft³), and is 50% smaller than our
previous model.
Comprehensive Warranty2 – The 12kW¹ unit includes a
four-year limited warranty2 - one of the best comprehensive
parts and labor warranties in the industry. At Milbank,
we stand behind our products (for more than 85 years!),
making it easy for our customers to work with us.
Flexible Placement3 – Tested against tough National
Fire Protection Agency standards, the Milbank
12kW¹ standby generator can be placed as close
as 18” from the home, providing more placement
options in your yard - perfect for tight lot lines.
Homeowner Safety & Protection – We take protection
to a whole new level - the 12kW1 comes with an external,
automatic gas shut-off valve, low pressure regulator and a
thermally-protected fuel system which automatically shuts
down the unit during an emergency (not found on any
other competing generator in its class).
Power Management Technology – Partner with an
automatic transfer switch to manage up to two loaddependent air conditioner units: 3-ton air conditioners for
10kW and 4-ton air conditioners for 12kW¹.
Durable Enclosure & Base – Our enclosures are made
from the same rust-resistant, durable Galvanneal steel
that is found in the automotive industry and features an
automotive-grade paint process which results in protection
against chipping and abrasions. Our enclosures and base
can endure temperatures of more than double that of
aluminum and plastic.
Low Pressure, No Problem - No need to worry if you live
in an area with low gas pressure. Milbank generators are
rated for 5” to 7” water column but can be as low as 3.5”
with proper accommodations.
Quiet Operation – The 12kW† is now 8% quieter than
previous models. Its fully electric governing system
creates a quieter more durable generator, allowing your
customers to live their lives uninterrupted.
Lightweight Composition – Weighing in at a mere 316
pounds, this generator boasts the lowest weight among
the competition in the 12kW size range - ideal for fast and
easy installation.
4
YEAR
WARRANTY
1
This generator is rated in accordance with UL (Underwriters Laboratories) 2200 (stationary engine generator assemblies) and CSA (Canadian Standards Association)
standard C22.2 No. 100-04 (motors and generators). 2Warranty details are available at milbankworks.com. 3Installations must strictly comply with all applicable codes,
industry standards, laws, regulations and provided installation manual. Running engines give off carbon monoxide, an odorless, colorless, poisonous gas so it is important to keep exhaust gas away from any windows, doors, ventilation intakes or crawl spaces. The installation manual contains specific instructions related to generator
placement in addition to NFPA 37, including the requirement that carbon monoxide detectors be installed and maintained in your home. | Actual product may vary
from image. | Milbank reserves the right to make changes in specifications and features shown without notice or discontinue the product described at any time without
notice or obligation. | Other Generator/Automatic Transfer switch manufacturers’ products are not compatible with Milbank Home Generator Systems.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
12kW
Home Standby Accessories
MAINTENANCE KIT
MG121822
Complete with special UL air filter, pre-cleaner, spark plugs, oil
filter, and synthetic oil.
COLD WEATHER KIT
MG111102
Complete with an oil heater and battery warmer - both
thermostatically controlled to heat up when the temperature
drops, ensuring smooth starting and engine operation. Tested
at -25ºF.
TRANSFER SWITCH
MATS20011
Milbank’s SynapSwitch™ is the latest innovation in automatic
transfer switches. The SynapSwitch™ calculates voltage and
frequency to manage power loads and allow pairing with a
smaller generator than in a non-management application.
*More Transfer Switch options available - contact the Milbank
sales team for more information.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
7
8
17 & 20kW
Home Standby Generators
MODELS
17kW1 | MG17001
20kW1 | MG20003
Innovative and intelligent, the 171 & 20kW1 deliver the
high performance homeowners expect. The unique airflow
technology coupled with sound-dampening compressed
fiberglass make these some of the quietest generators in
the industry, a diplomatic choice to keep neighbors happy.
FEATURES
Built for High-Performance – These units are built with
the extremely reliable Briggs & Stratton Commercial
Grade Vanguard Engine. Proven in applications around
the world, Vanguard’s OHV technology provides
superior balance, low vibration and emissions, and
better fuel economy. Our electronic governors
also provide stable, consistent power for sensitive
electronics and today’s most advanced appliances.
Comprehensive Warranty2 – Both the 17kW1 and 20kW1
units include a four-year limited warranty2 - one of the best
comprehensive parts and labor warranties in the industry.
At Milbank, we stand behind our products (for more than
85 years!), making it easy for our customers to work with
us.
Durable Enclosure & Base – Our enclosures are made
from the same rust-resistant, durable Galvanneal steel
that is found in the automotive industry and features an
automotive-grade paint process which results in protection
against chipping and abrasions. Our enclosures and base
can endure temperatures of more than double that of
aluminum and plastic.
Homeowner Safety & Protection – We take protection
to a whole new level - the 17kW1 and 20kW1 come with
an external, automatic gas shut-off valve, low pressure
regulator and a thermally-protected fuel system which
automatically shuts down the unit during an emergency
(not found on any other competing generator in its class).
These units also feature a corrugated metal fuel hose for
safer operation.
Flexible Placement3 – Tested against the tough
National Fire Protection Agency 37 standard, Milbank
171 & 20kW1 standby generators can be placed as
close as 18” from the home providing more placement
options in your yard*– perfect for tight lot lines.
Innovative Airflow Technology – This feature provides
better efficiency and longer life, and makes the 171 &
20kW1 our quietest generators. With the engine and
alternator intakes located in the rear, front ventilation
pushes the heat and carbon monoxide away from the
house - protecting homes, shrubs and landscaping from
damage.
Low Pressure, No Problem - No need to worry if you live
in an area with low gas pressure. Milbank generators are
rated for 5” to 7” water column but can be as low as 3.5”
with proper accommodations.
4
YEAR
WARRANTY
1
This generator is rated in accordance with UL (Underwriters Laboratories) 2200 (stationary engine generator assemblies) and CSA (Canadian Standards Association)
standard C22.2 No. 100-04 (motors and generators). 2Warranty details are available at milbankworks.com. 3Installations must strictly comply with all applicable codes, industry standards, laws, regulations and provided installation manual. Running engines give off carbon monoxide, an odorless, colorless, poisonous gas so it is important
to keep exhaust gas away from any windows, doors, ventilation intakes or crawl spaces. The installation manual contains specific instructions related to generator placement in addition to NFPA 37, including the requirement that carbon monoxide detectors be installed and maintained in your home. Milbank reserves the right to make
changes in specifications and features shown without notice or discontinue the product described at any time without notice or obligation. Other Generator/Automatic
Transfer switch manufacturers’ products are not compatible with Milbank Home Generator Systems.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
9
17 & 20kW
Home Standby Accessories
MAINTENANCE KIT
WIRELESS MONITOR
MG151822
MG622901
Complete with special UL air filter, pre-cleaner,
spark plugs, oil filter, and synthetic oil.
Easy, trouble-free monitoring is a
reality with the new Milbank Basic
Wireless Monitor.
Place the wireless
monitor in your
home and know
your generator is
working
without
ever having to go
outside.
COLD WEATHER KIT
WIRELESS ROUTER
MG623101
MG623501
Complete with a dual oil
heater and battery warmer
both
thermostatically
controlled to heat up when
the temperature drops,
ensuring smooth starting and
engine operation. Tested at
-25ºF.
A signal enhancement to
overcome obstructions. Recommended for applications
with distances of 100 feet or
more.
TRANSFER SWITCH
MG4002001S2
Milbank’s SynapSwitch™ is the latest innovation in automatic transfer
switches. The SynapSwitch™ calculates voltage and frequency to
manage power loads and allow pairing with a smaller generator than in
a non-management application.
*More Transfer Switch options available - contact the Milbank sales
team for more information.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
10
25kW
Commercial Standby Generators
MODELS
25kW1 | MG2524011BS
Help your customers protect their homes and
families from power outages with Milbank’s
liquid-cooled 25kW1 home generator
system. Perfect for medium-to-large homes,
we provide you with reliable power and
flexible options to meet your customers’
power needs.
FEATURES
Quality Power – Constant, reliable power is delivered to
sensitive appliances and electronics.
Powerful and Reliable Engine – The robust engine, built
and tested to Briggs & Stratton quality and durability
standards, delivers consistent performance resulting in
the dependability you expect from a backup generator.
User-friendly Controller – Conveniently monitors
diagnostic conditions, displays system service codes
and sets weekly exercise cycle - all from an easy-to-read
scrolling LED display.
Easy to Service – Convenient access to disassembly
points for quicker trouble-free servicing. The hinged
roof with gas shocks keep the roof open allowing for top
down access to the engine. While the easy to remove side
panels allow easy service access from the front and back.
Durable Enclosure – Rust-resistant, Galvanneal steel
enclosures are made from the same materials and paint
process used in the automotive industry, resulting in years
of protection against chips and abrasions.
Quick Response – Automatically powers your home in
seconds after sensing a power outage.
4-Year Limited Parts and Labor Warranty – At Milbank,
we stand behind our warranty and make it easy for our
customers to work with us.
4
YEAR
WARRANTY
1
These generator are rated in accordance with UL 2200 and CSA Standard C22.2 No. 100-04
Note: Installations must strictly comply with all applicable codes, industry standards, laws and regulations. Running engines give off carbon monoxide, an odorless,
colorless, poison gas so it is important to keep exhaust gas away from any windows, doors, ventilation intakes or crawl spaces. Carbon monoxide detectors must be
installed and maintained in your home.
Note: Milbank reserves the right to make changes in specifications and features shown without notice or discontinue the product described at any time without notice or
obligation. Warranty details available at milbankworks.com.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
25kW
Commercial Standby Accessories
MAINTENANCE KIT
MG626801
Complete with air and oil filters, funnel, synthetic oil, and spark plugs.
COLD WEATHER KIT
MG627001
Complete with a thermostatically controlled battery warmer and engine block
heater that activate as the temperature drops. Tested at -20° F.
INFOHUB™ WIRELESS MONITOR
MG62601H1
The infohubTM wireless monitor constantly observes your generator’s signal,
telling you what you want to know, when you want to know it. Using your
computer, tablet or smart phone, standby generator owners can instantly check
their generator’s system status from home or away.
WIRELESS MONITOR
MG626401
Easy, trouble-free monitoring is a reality with the new Milbank Basic Wireless
Monitor. Place the wireless monitor in your home and know your generator is
working without ever having to go outside.
SYNAPSWITCH™
MATS20012
Milbank’s SynapSwitch™ is the latest innovation in automatic transfer switches.
The SynapSwitch™ calculates voltage and frequency to manage power loads and
allow pairing with a smaller generator than in a non-management application.
TRANSFER SWITCH
MG4002001S2
The dual 400 amp / split 200 amp automatic transfer switch replaces the need
for two 200 Amp transfer switches in a standard split 400A service home with
two 200 Amp distribution panels. See page 17 for more details. Only available
with 20-62kW home standby and commercial generators.
* More Transfer Switch options available - contact the Milbank sales team for more information.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
11
12
35kW
Commercial Standby Generators
MODELS
35kW1
Available in single phase and three
phase models. Refer to specifications
for model numbers.
FEATURES
Comprehensive Commercial Warranty – Milbank
offers a four-year limited warranty² that includes
parts and labor. It’s one of the most comprehensive
warranties in the commercial standby power industry.
Custom Built Options – A complete line of
commercial standby generators for light commercial
applications with multiple voltage, configuration and
controller options available.
Industrial-Grade GM VortecTM Engine – This world
class four-cylinder GM VortecTM engine operates at
1800 RPM - quieter and more fuel-efficient than 3600
RPM engines.
Easier to Service – Convenient access points make it
easier to service and provide immediate access to the
entire engine without time-consuming disassembly.
Longer Product Life – A commercial generator is
a big investment. Designed for a longer life span,
Milbank’s commercial standby generators have lower
engine/alternator speeds, limited temperature rise
on the alternator, and corrosion-resistant, all-metal
enclosures.
Corrosion-Resistant Enclosure – Durable, all-metal
enclosures are built to last protecting against extreme
weather conditions and supported by the longest
enclosure warranty in the industry.
4
YEAR
WARRANTY
1
This generator is rated in accordance with UL (Underwriters Laboratories) 2200 (stationary engine generator assemblies) and CSA (Canadian Standards Association)
standard C22.2 No. 100-04 (motors and generators). 2Warranty details are available at milbankworks.com. 3Installations must strictly comply with all applicable codes, industry standards, laws, regulations and provided installation manual. Running engines give off carbon monoxide, an odorless, colorless, poisonous gas so it is important
to keep exhaust gas away from any windows, doors, ventilation intakes or crawl spaces. The installation manual contains specific instructions related to generator placement in addition to NFPA 37, including the requirement that carbon monoxide detectors be installed and maintained in your home. Milbank reserves the right to make
changes in specifications and features shown without notice or discontinue the product described at any time without notice or obligation. Other Generator/Automatic
Transfer switch manufacturers’ products are not compatible with Milbank Home Generator Systems.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
35kW
Commercial Standby Accessories
MAINTENANCE KIT
35kW | MG300022
Complete with special UL air filter, pre-cleaner, spark plugs, oil filter, and synthetic
oil.
ENGINE BLOCK HEATER
35kW | MG624101
Designed for maximum engine performance, engine block heaters keep engines
warm, allowing for faster and easier startups in cold weather. Milbank 35KW,
45kW and 60kW standby generators are tested to start at -20ºF using this kit.
Each kit includes an engine block heater and bracket.
SYNAPSWITCH™
MATS20012
Milbank’s SynapSwitch™ is the latest innovation in automatic transfer switches.
The SynapSwitch™ calculates voltage and frequency to manage power loads and
allow pairing with a smaller generator than in a non-management application.
VIGILANT®
400A | MGVATS4001208, MGVATS4001240, MGVATS4001480
The Vigilant® Series automatic transfer switch is designed to automatically transfer
critical loads in the event of a power outage. It consists of a simple, rugged
design while maintaining the flexibility required to meet the needs of residential,
agricultural, and light industrial applications.
TRANSFER SWITCH
MG4002001S2
The dual 400 amp / split 200 amp automatic transfer switch replaces the need
for two 200 Amp transfer switches in a standard split 400A service home with
two 200 Amp distribution panels. See page 17 for more details. Only available
with 20-62kW home standby and commercial generators.
* More Transfer Switch options available - contact the Milbank sales team for more information.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
13
14
48kW
Commercial Standby Generators
MODELS
48kW1
Available in single phase and three
phase models. Refer to specifications
for model numbers.
FEATURES
Comprehensive Commercial Warranty – Milbank
offers a four-year limited warranty² that includes
parts and labor. It’s one of the most comprehensive
warranties in the commercial standby power industry.
Custom Built Options – A complete line of commercial
standby generators for light commercial applications
with multiple voltage, configuration and controller
options available.
Industrial-Grade GM VortecTM Engine – This world
class eight-cylinder GM VortecTM engine operates at
1800 RPM - quieter and more fuel-efficient than 3600
RPM engines.
Easier to Service – Convenient access points make it
easier to service and provide immediate access to the
entire engine without time-consuming disassembly.
Longer Product Life – A commercial generator is
a big investment. Designed for a longer life span,
Milbank’s commercial standby generators have lower
engine/alternator speeds, limited temperature rise
on the alternator, and corrosion-resistant, all-metal
enclosures.
Corrosion-Resistant Enclosure – Durable, all-metal
enclosures are built to last protecting against extreme
weather conditions and supported by the longest
enclosure warranty in the industry.
4
YEAR
WARRANTY
1
This generator is rated in accordance with UL (Underwriters Laboratories) 2200 (stationary engine generator assemblies) and CSA (Canadian Standards Association)
standard C22.2 No. 100-04 (motors and generators). 2Warranty details are available at milbankworks.com. 3Installations must strictly comply with all applicable codes, industry standards, laws, regulations and provided installation manual. Running engines give off carbon monoxide, an odorless, colorless, poisonous gas so it is important
to keep exhaust gas away from any windows, doors, ventilation intakes or crawl spaces. The installation manual contains specific instructions related to generator placement in addition to NFPA 37, including the requirement that carbon monoxide detectors be installed and maintained in your home. Milbank reserves the right to make
changes in specifications and features shown without notice or discontinue the product described at any time without notice or obligation. Other Generator/Automatic
Transfer switch manufacturers’ products are not compatible with Milbank Home Generator Systems.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
48kW
Commercial Standby Accessories
MAINTENANCE KIT
48kW | MG450022
Complete with special UL air filter, pre-cleaner, spark plugs, oil filter, and synthetic
oil.
ENGINE BLOCK HEATER
48kW | MG624201
Designed for maximum engine performance, engine block heaters keep engines
warm, allowing for faster and easier startups in cold weather. Milbank 35KW,
45kW and 60kW standby generators are tested to start at -20ºF using this kit.
Each kit includes an engine block heater and bracket.
SYNAPSWITCH™
MATS20012
Milbank’s SynapSwitch™ is the latest innovation in automatic transfer switches.
The SynapSwitch™ calculates voltage and frequency to manage power loads and
allow pairing with a smaller generator than in a non-management application.
VIGILANT®
400A | MGVATS4001208, MGVATS4001240, MGVATS4001480
The Vigilant® Series automatic transfer switch is designed to automatically transfer
critical loads in the event of a power outage. It consists of a simple, rugged
design while maintaining the flexibility required to meet the needs of residential,
agricultural, and light industrial applications.
TRANSFER SWITCH
MG4002001S2
The dual 400 amp / split 200 amp automatic transfer switch replaces the need
for two 200 Amp transfer switches in a standard split 400A service home with
two 200 Amp distribution panels. See page 17 for more details. Only available
with 20-62kW home standby and commercial generators.
* More Transfer Switch options available - contact the Milbank sales team for more information.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
15
16
60&62kW
Commercial Standby Generators
MODELS
60 and 62kW1
Available in single phase and three
phase models. Refer to specifications
for model numbers.
FEATURES
Comprehensive Commercial Warranty – Milbank offers
a four-year limited warranty² that includes parts and labor.
It’s one of the most comprehensive warranties in the
commercial standby power industry.
Industrial-Grade GM VortecTM Engine – This world class
eight-cylinder GM VortecTM engine operates at 1800 RPM
- quieter and more fuel-efficient than 3600 RPM engines.
Longer Product Life – A commercial generator is a big
investment. Designed for a longer life span, Milbank’s
commercial standby generators have lower engine/
alternator speeds, limited temperature rise on the
alternator, and corrosion-resistant, all-metal enclosures.
Power Management Technology – Milbank’s automatic
transfer switch comes standard with our patented power
management technology managing up to two loaddependent air conditioner units while keeping critical
home or business applications powered.
Easier to Service – Convenient access points make it
easier to service and provide immediate access to the
entire engine without time-consuming disassembly.
Corrosion-Resistant
Enclosure – Durable, all-metal
enclosures are built to last protecting against extreme
weather conditions and supported by the longest enclosure
warranty in the industry.
Custom Built Options – A complete line of commercial
standby generators for light commercial applications with
multiple voltage, configuration and controller options
available.
4
YEAR
WARRANTY
1
This generator is rated in accordance with UL (Underwriters Laboratories) 2200 (stationary engine generator assemblies) and CSA (Canadian Standards Association)
standard C22.2 No. 100-04 (motors and generators). 2Warranty details are available at milbankworks.com. 3Installations must strictly comply with all applicable codes, industry standards, laws, regulations and provided installation manual. Running engines give off carbon monoxide, an odorless, colorless, poisonous gas so it is important
to keep exhaust gas away from any windows, doors, ventilation intakes or crawl spaces. The installation manual contains specific instructions related to generator placement in addition to NFPA 37, including the requirement that carbon monoxide detectors be installed and maintained in your home. Milbank reserves the right to make
changes in specifications and features shown without notice or discontinue the product described at any time without notice or obligation. Other Generator/Automatic
Transfer switch manufacturers’ products are not compatible with Milbank Home Generator Systems.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
60&62kW
Commercial Standby Accessories
MAINTENANCE KIT
60kW | MG450022
62kW [3Ø] | MG450022
Complete with special UL air filter, pre-cleaner, spark plugs, oil filter, and synthetic
oil.
ENGINE BLOCK HEATER
60kW | MG624201
62kW [3Ø] | MG624201
Designed for maximum engine performance, engine block heaters keep engines
warm, allowing for faster and easier startups in cold weather. Milbank 35KW,
45kW and 60kW standby generators are tested to start at -20ºF using this kit.
Each kit includes an engine block heater and bracket.
VIGILANT®
400A | MGVATS4001208, MGVATS4001240, MGVATS4001480
The Vigilant® Series automatic transfer switch is designed to automatically transfer
critical loads in the event of a power outage. It consists of a simple, rugged
design while maintaining the flexibility required to meet the needs of residential,
agricultural, and light industrial applications.
TRANSFER SWITCH
MG4002001S2
The dual 400 amp / split 200 amp automatic transfer switch replaces the need
for two 200 Amp transfer switches in a standard split 400A service home with
two 200 Amp distribution panels. See page 17 for more details. Only available
with 20-62kW home standby and commercial generators.
* More Transfer Switch options available - contact the Milbank sales team for more information.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
17
18
25-600kW
Industrial Standby Generators
MODELS
25-600kW
Milbank offers a full line of industrial dieseland gaseous-powered standby generators.
Standby options include open, level 1 and level
2 aluminum enclosures with a DeepSea 7420
controller
FEATURES
DeepSea 7420 Digital Controller - Our DeepSea 7420
Digital Controller monitors speed, frequency, voltage,
current, oil pressure, coolant temperature and fuel levels.
Allowing programming to basic engine functions in the
field, the controller also has stop-manual-auto mode and
engine shutdowns, signaled by full-text, continuous-display
LCD indicators.
Heavy-Duty Industrial Engine - Each industrial standby
generator set is powered by a heavy-duty John Deere, MTU,
GM or PSI engine – providing years of reliable, trouble-free
operation.
Two-Year Warranty - All of Milbank’s industrial standby
generator systems include a two-year warranty. At Milbank,
we stand behind our products (for more than 85 years!),
making it easy for our customers to work with us.
Standard Equipment Included - All standby industrial
generators include a 12VDC float battery charger, silencer
(for Level I and Level 2 units only), flexible coolant and oil
drain hose, battery, battery tray and cables, programmable,
DeepSea 7420 Digital Controller and mainline circuit breaker
ACCESSORIES/OPTIONS
• Engine coolant heater with automatic 80°F on, 100°F off, • A
ll brushed type, 304 stainless steel weather and sound
•
•
•
•
thermostat.
Starting battery heater blanket with automatic 60°F on,
80°F off, thermostat.
Battery charger upgrade, float type, 12 VDC at max.
charge with ammeter on charger.
External permanent magnet generator (PMG) for increased induction motor starting capacity on 1Ø or 3Ø
sets and to meet NFPA-110 requirements.
Exhaust silencer critical grade or hospital grade (replacing
standard residential grade).
•
•
deadening housing for coastal areas.
D
SE WebNet Gateway expansion module will allow
communications with a host server via Ethernet and
the DSE cloud connection for mapping static locations,
real time instrumentation, control event log tables, and
automatic system alerts via email.
R
emote annunciator for up to (10) reporting functions.
An additional relay expansion module, plus a second
annunciator adds another (10) reporting functions.
Specifications & ratings are subject to change without prior notice.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
19
25-600kW
Industrial Standby Generators
CONTROL PANEL
DeepSea 7420 digital microprocessor with
logic allows programming in the field.
Controller has:
• STOP-MANUAL-AUTO modes
and automatic engine shutdowns,
signaled by full text LCD indicators:
• Low oil pressure
• Engine fail to start
• High engine temp
• Engine over speed
• Low radiator level
• Engine under speed
• Three auxiliary alarms
• Over & under voltage
• Battery fail alarm
•A
lso included is tamper-proof
engine hour meter
MODELS | GASEOUS
MG25 | 25kW
MG30 | 28-30kW
MG41 | 40-41kW
MG52 | 50-52kW
MG62 | 58-62kW
MG80 | 75-80kW
MG96 | 80-96kW
MG120 | 110-120kW
MG150 | 130-150kW
MG200 | 200kW
MG265 | 265kW
MG300 | 300kW
MG350 | 350kW
MG400 | 400kW
MG425 | 425kW
MGD210 | 210kW
MGD250 | 250kW
MGD280 | 280kW
MGD300 | 300kW
MGD350 | 350kW
MGD400 | 400kW
MGD450 | 450kW
MGD500 | 500kW
MGD550 | 550kW
MGD600 | 600kW
MODELS | DIESEL
MGD30 | 30kW
MGD60 | 60kW
MGD80 | 75-80kW
MGD100 | 100kW
MGD125 | 125kW
MGD155 | 151-155kW
2
YEAR
WARRANTY
Specifications & ratings are subject to change without prior notice.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | | milbankworks.com
milbankworks.com
20
50-200 Amp
Transfer Switches
MODELS
50A | MG0503120
100A | MG1003162
100A | MG1003002
200A | MG2003002
2 X 200A | MG4002001S2**
FEATURES
Fully Automatic – All transfer switches monitor utility and
generator voltages and will automatically connect to the
appropriate source of power. 100 and 200 amp switches
are capable of whole–house power transfer in residential/
small business applications.
EEPROM (Electronic Program Read–Only Memory) – All
transfer switches feature non–volatile memory, so when
the power goes out, the transfer switch “remembers” its
programming once power is restored. The switch never has
to be programmed or reprogrammed once it is installed.
Exclusive Design – Each transfer switch is UL approved,
custom–made and dedicated exclusively for Milbank,
reducing overall cost and giving you exactly what you
need for your home or small business.
Variable Engine Warm–Up – All of our switches feature
both 20–second and 50–second warm–up options: 20
seconds for warm weather starts or a 50 second setting
when the generator requires additional start time in colder
climates.
Lightweight/Ease of Installation – Efficient component
selection has resulted in switch gear optimization for a
lightweight product solution to residential/small business
installations. Five wires — three 120/240 VAC and two
utility supply wires (for battery charger and optional
battery warmer and oil heater) also allow for efficient one–
person installation.
Safety Features – All transfer switches are solenoid–
operated from utility or generator inputs and contain
electrical interlock switches to eliminate the possibility of
dangerous back–feed to a line during an outage.
3–Year Limited Parts and Labor Warranty – One of the
most comprehensive parts and labor warranties in the
industry.
3
YEAR
WARRANTY
**Can only be sold with the purchase of a 20, 30, 45 or 60kW home standby generator (not by itself).
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
Dual 200 Amp / Split 400 Amp
21
Transfer Switches
MODEL
MG4002001S2
The Milbank Dual 200 Amp / Split 400 Amp Transfer Switch replaces the need for two 200 Amp transfer switches in standard split 400A service homes with two 200A distribution panels. It’s a convenient and affordable solution to manage
whole-house backup power for larger homes and businesses.
FEATURES
Symphony® II Power Management – Allows for whole-house power and the
prioritization of up to 8 high-wattage appliances.
First In Its Class – Never seen before automatic transfer switch technology
only compatible with Milbank generators.
Easy Installation – The system uses one less transfer switch requiring less
wiring, less time and expenses than typical installations. Plus factory pre-wired
generator power distribution inside the transfer switch simplifies installation.
Smaller Footprint – Combining two automatic transfer switches into one, the
Dual 200 Amp Transfer Switch / Split 400 Amp results in a smaller, cleaner
looking installation for your customer.
3
YEAR
WARRANTY
*Review local codes to determine if a transfer switch with separate service entrance disconnect is required. Installers are required to review local codes prior to installation to
determine if a transfer switch with separate disconnect is required. All installations must strictly comply with all applicable codes, industry standards, laws and regulations,
and installation manual. Improper installation will void all warranties. Milbank reserves the right to make changes in specifications and features shown without notice or
discontinue the product described at any time without notice or obligation. Other Generator/Automatic Transfer switch manufacturers’ products are not compatible with
Milbank Home Generator Systems.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346
Milbank
| milbankworks.com
| 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
22
MODELS
100A | MATS10011
150A | MATS15012
200A | MATS20011
200A | MATS20012
Milbank is proud to introduce the new SynapSwitchTM | Automatic Transfer Switch
(ATS). Compatible with our 8-48kW home standby generators, the SynapSwitchTM
will immediately signal your generator to start up in the event of a power outage - so
when the power goes out, you won’t be left in the dark.
POWER MANAGEMENT
MATS50RM
Load Control Module - The Milbank Load Control Module paired with a Milbank
SynapSwitchTM seamlessly manages power loads when under generator power. Using the
Milbank Load Control Module can allow for a smaller generator to cover the load of a nonmanaged larger generator. Milbank Load Control Modules can be added per the application
using one to four modules as needed. By using a module per load, the SynapSwitchTM is
scalable and allows for flexibility in adding additional power management in the future.
FEATURES
Load Management - The SynapSwitchTM manages two
electrical loads on its own and can manage additional loads
when paired with Load Control Module. This can enable
you to receive whole-house power from a smaller generator.
Intelligent Synap Technology - This switch uses state-ofthe-art technology that constantly measures power (voltage
x current) and frequency.
Load Priority - The switch intelligently selects managed
loads based on priority or load size.
LED Status Indicator - The indicator shows whether load
is under utility or generated power and indicates which
managed loads are on or off.
Certified to FCC Chapter 15 Part B - The ATS adheres to
the strictest code for electronic design to avoid interference
with radio and WiFi signals.
Generator Disconnect - The external disconnect allows the
generator to be quickly taken out of service in the event of
emergency shutoff.
NEMA 3R Cabinet - This durable enclosure is suitable for
indoor or outdoor installations.
Adaptability - The intelligent switch automatically adapts
to seasonal changes of the loads.
Easy installation - The lightweight SynapSwitchTM is easy
to install and service. With a variety of knockouts and plugand-play parts, this switch is a contractors turnkey solution.
3
YEAR
WARRANTY
Installers are required to review local codes prior to installation to determine if a transfer switch with separate disconnect is required. All installations must strictly comply with all applicable codes, industry standards, laws and regulations, and installation manual. Improper installation will void all warranties. Milbank reserves the right to make changes in specifications and features shown without notice or discontinue
the product described at any time without notice or obligation. Other Generator/Automatic Transfer switch manufacturers’ products are not compatible with Milbank Home Generator Systems.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
23
MODELS
100A | MGVATS1001240
200A | MGVATS2001240
400A | MGVATS4001240
400A | MGVATS4001208
400A | MGVATS4001480
600A | MGVATS6001240
600A | MGVATS6001208
600A | MGVATS6001480
1000A | MGVATS10001240
1000A | MGVATS10001208
1000A | MGVATS10001480
1250A | MGVATS12501208
1250A | MGVATS12501480
The Vigilant® Series automatic transfer switch is designed to automatically transfer critical loads in
the event of a power outage. It consists of a simple, rugged design while maintaining the flexibility
required to meet the needs of residential, agricultural and light industrial applications.
FEATURES
Galvanized Steel Enclosure – This duplex coated,
galvanized G90 grade steel meets American Society for
Testing and Materials (ASTM) standard A653. The service
life more is than twice that of regular steel; standard on all
Vigilant® series transfer switches.
Exterior Accessibility – The easy–to–use, 7–day exerciser
clock gives full control over day and time. The exerciser
clock and indicator lamps are both accessible from outside
the transfer switch – no need to open the door, even with
the NEMA 3 enclosure option.
• Powered from genset battery for isolation against line
transients.
• Integrated voltage and frequency sensing.
• Adjustable
transfer
delays
using
on–board
potentiometers.
• Fused remote start contact relays.
• Adjustable drop–out & pick–up values for voltage and
frequency.
• Internal test switch included.
Comprehensive Warranty – Milbank offers one of the best
in the industry with a 5-year limited parts and labor warranty.
VTSC100 Logic Controller Board – The controls harbored
in the center of every Vigilant® automatic transfer switch.
It is designed to provide all basic transfer switch control
functions with simplicity, flexibility, and durability.
Features include:
5
YEAR
WARRANTY
Installers are required to review local codes prior to installation to determine if a transfer switch with separate disconnect is required. All installations must strictly comply with all applicable
codes, industry standards, laws and regulations, and installation manual. Improper installation will void all warranties. Milbank reserves the right to make changes in specifications and features
shown without notice or discontinue the product described at any time without notice or obligation. Other Generator/Automatic Transfer switch manufacturers’ products are not compatible with
Milbank Home Generator Systems.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
24
30 & 50 Amp | Manual Transfer Switch
Manual Transfer Switches
MODELS
MMTTS301*
MMTS301L*
MMTS301SYSX
MMTS301SYSX1C
MMTS301SYSX2C
MMTS301SYSL
MMTS301SYSL1C
MMTTS501*
MMTS501L*
MMTS501SYSX
MMTS501SYSX1C
MMTS501SYSX2C
MMTS501SYSL
MMTS301SYSL1C
*Model without Learn Function
FEATURES
Learn Function* — Our patent-pending feature memorizes the
capacity of the generator, which helps prevent your generator from
overloading.
Exclusive LED Digital Meter* — Illuminated LED display for easyto-read generator output information in all lighting conditions.
30 Amp and 50 Amp models available —Safely connects most
common sizes of portable generators.
Wiring Harness* — Ready to install out of the box for quick and
easy installation.
Interlock Assembly — Designed to prevent your generator and
utility from running at the same time to ensure safe operation and
to protect your generator.
Easy-to-read LED
digital meter &
Learn Function for
easy set up
Patent - pending
4
IND
LEAUSTRY
DIN
G
YEAR
WARRANTY
*Review local codes to determine if a transfer switch with separate service entrance disconnect is required. Installers are required to review local codes prior to installation to determine if a transfer
switch with separate disconnect is required. All installations must strictly comply with all applicable codes, industry standards, laws and regulations, and installation manual. Improper installation will
void all warranties. Milbank reserves the right to make changes in specifications and features shown without notice or discontinue the product described at any time without notice or obligation. Other
Generator/Automatic Transfer switch manufacturers’ products are not compatible with Milbank Home Generator Systems.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
25
30 & 50 Amp | Manual Transfer Switch
Manual Transfer Switches
MILBANK 30A MANUAL SWITCH PACKAGES
60 Amp 30 Amp
Utility Generator
Breaker
Breaker
6 Branch
Breakers
(2) 15 Amp
(2) 20 Amp
(2) 30 Amp
6’
Wiring
Harness
Included
2 expandable
30 Amp
Inlet
Installed in
MTS
NEMAL14-30-C
Exclusive LED
Digital Meter
with Learn
Function
Separate
Power Inlet
Box with 30
Amp Plug
(NEMA 3R)
MMTS301*
X
X
MMTS301L*
X
X
MMTS301SYSX
X
X
X
X
X
X
MMTS301SYSX1C
X
X
X
X
X
X
MMTS301SYSX2C
X
X
X
X
X
X
MMTS301SYSL
X
X
X
X
X
X
MMTS301SYSL1C
X
X
X
X
X
X
MMTS301SYSL2C
X
X
X
X
X
X
125/ 250 VAC,
Connectors –
NEMAL14-30-P
NEMAL14-30-C
10’
Cord
25’
Cord
X
X
X
X
X
*Model without Learn Function
MILBANK 50A MANUAL SWITCH PACKAGES
100 Amp
Utility
Breaker
50 Amp
Generator
Breaker
6 Branch
Breakers
(2) 15 Amp
(2) 20 Amp
(2) 50 Amp
6’ Wiring
Harness
Included
50A Inlet
Installed
in MTS
CS6375
2 expandable
Exclusive
LED Digital
Meter
with Learn
Function
Separate
Power Inlet
Box with 50
Amp plug
(NEMA 3R)
MMTS501*
X
X
MMTS501L*
X
X
MMTS501SYSX
X
X
X
X
X
X
MMTS501SYSX1C
X
X
X
X
X
X
MMTS501SYSX2C
X
X
X
X
X
X
MMTS501SYSL
X
X
X
X
X
X
MMTS501SYSL1C
X
X
X
X
X
X
MMTS501SYSL2C
X
X
X
X
X
X
125/ 250 VAC,
Connectors –
CS6365C
CS6364C
10’
Cord
25’
Cord
X
*Model without Learn Function
Running engines give off carbon monoxide, an odorless, colorless, poisonous gas so it is important to keep exhaust gas away from any windows, doors, ventilation intakes
or crawl spaces. Not for indoor use. Milbank reserves the right to make changes in specifications and features shown without notice or discontinue the product described
at any time without notice or obligation.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
X
X
X
X
26
1000 & 1800W
Digital Inverter Generators
Ideal for the contractor on the go or outdoorsy weekend warrior – Milbank’s digital inverters provide reliable,
quiet and clean energy for all sensitive electronic needs. The 4-cycle gasoline-powered inverters provide two
120V, AC outlets.
ITH
NOW W
L
E ING
PARALL
ITY
CAPABIL
1000W | MPG1000I
1800W | MPG2000IP
FEATURES
• Asymmetrical Fans
• Dual Muffler Design
• Run time @ 1/2 load:MPG1000I 9 hours
MPG2000IP 11 hours
• Double Insulated Acoustic Hood
• Sound Output, 53-59 dba NL/FL
• Power Indicator Light
• Less Than 3% Total Harmonic Distortion (THD)
• AC Overload Reset
• Tool Kit and Oil Bottle included
• High Efficiency Run Mode
• MPG2000IP will feature capabilities allowing two
• Low Oil Shut Down
units to be used in parallel.
• Light Weight, Ergonomically Designed
• 12 volt power outlet
• Model #INVPCORD1
- 1000W – 30 lbs.
- 1800W – 43 lbs.
PARALLEL CORD | INVPCORD1
*Review local codes to determine if a transfer switch with separate service entrance disconnect is required. Installers are required to review local codes prior to installation to determine if a transfer
switch with separate disconnect is required. All installations must strictly comply with all applicable codes, industry standards, laws and regulations, and installation manual. Improper installation will
void all warranties. Milbank reserves the right to make changes in specifications and features shown without notice or discontinue the product described at any time without notice or obligation. Other
Generator/Automatic Transfer switch manufacturers’ products are not compatible with Milbank Home Generator Systems.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
27
3250-10,000W
Portable Generators
From campsite to job site, from tent to trailer, and all points in between, Milbank’s rugged, dependable
portable generators put the power in your hands to get the job done. From 3250W to 10,000W, trust in
Milbank’s comprehensive line of EPA–compliant portable generator solutions to deliver power when you want
it, wherever you need it.
3250W | MPG32501
5500W | MPG55003
6000W | MPG6000S
6500W | MPG6500E
7000W | MPG70002E
7500W | MPG75002E
10,000W | MPG100001E
FEATURES
3250-7500W
• 3-year warranty
• 11-14 hours run time
• EPA compliant
• Quiet operation; the Pulse-Flow muffler makes it
one of the quietest generators on the market
• Simplified operator control center; clean,
simple and easy to use to harness the power
you need, when you need it
• Exclusive VR system allows voltage–regulated
power protection for all your electronic needs
• Iron–sleeved engine for long–lasting durability
and low maintenance
• Light weight, easy to move with durable wheels
100-199 lbs.
• Wheel kit, toolkit and fuel gauge included
Power Cord | MPGCORD25
10,000W
• 3-year warranty
• 12 hour run time
• EPA compliant & CARB (California Air Resources
Board) compliant
• 9.2 Gallon Fuel Tank
• Full GFCI-protected control panel monitors all
receptacles for ground faults
• Low oil shutdown
• Pulse-FloTM Muffler
• Full cage steel frame
• Fuel tank drain system included
• Easily converts from a bonded neutral to a floating
neutral, under the alternator cover
• Bonus DC battery charger included
• Less than 5% total harmonic distortion (THD) - safe
for all sensitive electronics
• Wheel kit, toolkit and fuel gauge, battery and hour
meter included
3
YEAR
WARRANTY
Running engines give off carbon monoxide, an odorless, colorless, poisonous gas so it is important to keep exhaust gas away from any
windows, doors, ventilation intakes or crawl spaces. Not for indoor use. Milbank reserves the right to make changes in specifications and
features shown without notice or discontinue the product described at any time without notice or obligation.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
28
Features & Applications
Enclosed Controls
Enclosed controls from Milbank are the perfect alternative to traditional “strut farm” structures,
providing superior security and appearance while taking just a fraction of the time to install. All
electrical equipment (lug landing, meter socket, distribution and control equipment) are protected
inside an attractive, vandal-resistant Type 3R cabinet. Milbank generators can be paired with Milbank
enclosed controls to offer a total package solution for backup power needs.
FEATURES
Typical Applications – Applications include traffic
intersections, landscape irrigation and lighting,
cell tower sites, temporary power for festivals
and events, pump and lift stations, and roadway
and parking lot lighting.
Electrical Equipment – Electrical equipment
including the generator receptacle, is built inside
the pedestal giving it a clean appearance and
making it extremely vandal resistant.
Pedestal – Several standard stock pedestals
are available, or send your requirements to our
configuration experts and Milbank will design a
pedestal to meet your specifications. Wall-mount
and pole-mount enclosure options are also
available.
Finishing – Available in steel, stainless steel and
aluminum constructions with powder-coat paint
finishes in any color.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements prior to ordering or installing this equipment. This product must be installed by a
licensed electrician. Installation of this equipment may require local electrical inspector approval.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
CP3B “Power Transfer” Series
29
Enclosed Controls
The Milbank BBS Series Commercial Pedestals are designed to provide battery backup power for
various loads, and to switch specific loads on and off under certain conditions; a photoelectric cell or
time clock to control lighting circuits, as an example. Metered and non-metered power distribution
options are available. The back-up power pedestal is designed to handle the vast majority of todays
back-up power requirements.
By using 19” rack design, shelves can be adjusted to accommodate the required batteries and
manufactures DC to AC inverters, transfer switches and other related equipment. This design gives
the user a wide range of design and configuration options. Complete turnkey, ready to power-up
pedestals are offered along with basic units ready to accept batteries and inverters supplied by
others.
FEATURES
•
•
•
•
•
•
•
•
•
•
•
•
120/240V 1Ø3W thru 277/480V 3Ø4W ratings
Metered or unmetered units
Choice of EUSERC ring type or ringless meter sockets
60 amps thru 400 amp ratings
UL Listed Type 3R rated
Pad lockable, isolated utility compartments
20 amp GFI convenience receptacle
Lockable recessed generator receptacle door
Utility and generator indicator light options
All stainless steel hardware
Galvanized steel, aluminum or stainless steel cabinet options
Custom designs available
Generator receptacle
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
30
Contractor Benefits
Authorized Generator Technician Certification
RIZED GENERAT
HO
O
T
U
Become a Milbank Authorized Generator Technician (MAG-T)with
Milbank’s two-day certification class. This technical certification
provides electrical contractors with the knowledge needed to install
and perform warranty repairs on Milbank home standby generator
units.
R
A
BECOME A MILBANK AUTHORIZED GENERATOR TECHNICIAN
TEC
HNICIAN
2015 Certification Dates:
May 5-6
August 11-12
November 10-11
Location:
Milbank National Training Center | Kansas City, Mo.
Milbank’s generator certification class is required for any licensed
electrical contractor who would like to be authorized to perform
field repairs under Milbank’s warranty policies and procedures. This
certification is not required for installing Milbank home generator
systems or performing routine maintenance.
For more information visit milbankworks.com/MAGT or contact Milbank’s technical training
and support team at [email protected]
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
Distributor Benefits
Milbank OneSERT
31
The next natural disaster affecting your area is not a matter of IF, it’s
a matter of WHEN. And when that time comes, you need immediate
world-class service. That’s why Milbank offers OneSERT, your One-Stop
Emergency Response Team to get you the product you need, when you
need it.
During normal business hours Monday - Friday, 8 a.m. - 5 p.m. CST - call
our office at 816-410-7346.
A single call to 800-227-5564 sets the OneSERT team in motion:
• After-hours call support 24 hours per day, 365 days per year
• Single point of contact to coordinate all aspects of the
order
• Expedited product availability
• Optional solutions on product applications
• Fast, reliable service
When a natural disaster strikes your area, put the country’s leading
manufacturer of meter sockets and related products on your team. Call
Milbank’s OneSERT emergency line at 800-227-5564 or milbankworks.
com/OneSERT.
Note: this program as well as emergency portable generator stock
(pictured below) is available only to our current electrical distributors.
800 - 227 - 5564
Running engines give off carbon monoxide, an odorless, colorless, poisonous gas so it is important to keep exhaust gas away from any windows, doors, ventilation intakes or crawl spaces. Not for indoor
use. Milbank reserves the right to make changes in specifications and features shown without notice or discontinue the product described at any time without notice or obligation.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
32
Technical Specifications
Home Standby Generators
MODEL NUMBER
Watts LP/NG
Main Breaker (Amps)
MG08001
8kW
MG10002
10kW
8,000W (LP) / 6,000W (NG)
10,000W (LP) / 9,000W (NG)
35
50
33.3 / 29.9
41.7 / 37.5
120/240V AC, Single Phase, 1.0 pf
120/240V AC, Single Phase, 1.0 pf
Brushed
Brushed
Harmonic Distortion
Less than 5%
Less than 5%
Voltage Regulation
Automatic
Automatic
Propane (LP), Natural Gas
Propane (LP), Natural Gas
76.8 dB
72.3 dB
Full Pressure Lubrication
Yes
Yes
Overcrank Protection
Yes
Yes
28 x 24.4 x 35.1
28 x 24.4 x 35.1
252 lbs
272 lbs
Amps LP/NG
Voltage
Alternator
Fuel Type
Sound Rating (at 7 Meters)
Dimensions (in inches: L x W x H)
Weight (Generator Only)
Orientation
Limited Warranty*
NFPA-37 Compliant
Vertical
Vertical
3 year P/L (limited)
3 year P/L (limited)
Yes
Yes
Cold Weather Kit
MG626201(sold separately)
MG111102 (sold separately)
Maintenance Kit
MG080022 (sold separately)
MG101222 (sold separately)
Turnkey Extras Included
Hour Meter, Battery Charger, Steel Base, External Automatic Shut-off Valve, Low Pressure Regulator, Thermally Protected Fuel System and Synthetic Oil
FUEL CHARACTERISTICS
Fuel Consumption | LP
(at 1⁄2 load)
37.6 Ft3/Hr 1.04 Gal/Hr
94,000 BTU
42.8 Ft3/Hr 1.18 Gal/Hr
107,000 BTU
Fuel Consumption | NG
(at 1⁄2 load)
94 Ft3/Hr
94,000 BTU
111 Ft3/Hr
111,000 BTU
Fuel Consumption | LP
(at full load)
56.4 Ft3/Hr 1.57 Gal/Hr
141,000 BTU
65.6 Ft3/Hr 1.82 Gal/Hr
164,000 BTU
Fuel Consumption | NG
(at full load)
121 Ft3/Hr
121,000 BTU
169 Ft3/Hr
169,000 BTU
Water Pressure
* Requires extra accommodation
NG 3.5* to 7”
LP 11” - 14”
NG 3.5* to 7”
LP 11” - 14”
BATTERY REQUIREMENTS
Volts (standard/cold start)
Minimum AMPS (standard/cold start)
12 Volt DC
12 Volt DC
540 CCA / 800 CCA
540 CCA / 800 CCA
Type
Wet Lead Acid
Wet Lead Acid
Terminal Hardware
Top Post Type
Top Post Type
Dimensions (Max)
BCI size 26 or 51 (BCI size 24 cold start, less than
32°F)
BCI size 26 or 51 (BCI size 24 cold start, less than 32°F)
500 cc Briggs & Stratton Intek
570 cc Briggs & Stratton Commercial Vanguard™VTwin
1 Cylinder - 4 Cycle
2 Cylinder - 4 Cycle
3600
3600
Yes
Yes
ENGINE SPECIFICATIONS
Engine
Cylinders
Operating RPM
California Compliant
These generators are rated in accordance with UL 2200 and CSA Standard C22.2 No. 100-04. Fuel consumption rates are estimated based on normal operating conditions. Generator operation may be greatly affected by elevation and the cycling
operation of multiple electrical appliances - fuel flow rates may vary depending on these factors. Installations must strictly comply with all applicable codes, industry standards, laws and regulations, installation manual. Other Generator/Automatic
Transfer Switch manufacturers products are not compatible with Milbank Home Generator Systems. Improper installation voids all warranty. Milbank reserves the right to make changes in specifications and features shown without notice or discontinue the product described at any time without notice or obligation. † Current model available is 15kW CARB.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
33
Technical Specifications
MG12003
12kW
MG17001
17kW
MG20003
20kW
12,000W (LP) / 10,000W (NG)
17,000W (LP) / 15,300W (NG)
20,000W (LP) / 18,000W (NG)
60
80
100
50 / 41.7
67 / 60
83.3 / 75
120/240V AC, Single Phase, 1.0 pf
120/240V AC, Single Phase, 1.0 pf
120/240V AC, Single Phase, 1.0 pf
Brushless
Brushed
Brushed
Less than 5%
Less than 5%
Less than 5%
Automatic
Automatic
Automatic
Propane (LP), Natural Gas
Propane (LP), Natural Gas
Propane (LP), Natural Gas
69 dB, 3600 RPM, per ISO 3744
69.1 dB, 3600 RPM, per ISO 3744
69.1 dB, 3600 RPM, per ISO 3744
Yes
Yes
Yes
Yes
Yes
Yes
28 x 24.5 x 37.2
48 x 34 x 31
48 x 34 x 31
318 lbs
484 lbs
500 lbs
Vertical
Horizontal
Horizontal
4 year P/L (limited)
4 year P/L (limited)
4 year P/L (limited)
Yes
Yes
Yes
MG111102 (sold separately)
MG623101 (sold separately)
MG623101 (sold separately)
MG121822 (sold separately)
MG151822 (sold separately)
MG151822 (sold separately)
Hour Meter, Battery Charger, Installation Base,
External Automatic Shut-off Valve, Low Pressure
Regulator, Thermally Protected Fuel System and
Synthetic Oil, Wired Remote Status Monitor
Hour Meter, Battery Charger, Steel Base, External Automatic Shut-off Valve, Low Pressure Regulator,
Thermally Protected Fuel System and Synthetic Oil 12002
61.8 Ft3/Hr 1.7 Gal/Hr
155,000 BTU
74 Ft3/Hr 2.06 Gal/Hr
185,000 BTU
83 Ft3/Hr 2.31 Gal/Hr
207,500 BTU
117 Ft3/Hr
117,000 BTU
170 Ft3/Hr
70,000 BTU
187 Ft3/Hr
187,000 BTU
83.8 Ft3/Hr 2.3 Gal/Hr
209,000 BTU
118 Ft3/Hr 3.28 Gal/Hr
295,000 BTU
135 Ft3/Hr 3.75 Gal/Hr
337,500 BTU
172 Ft3/Hr
172,000 BTU
248 Ft3/Hr
248,000 BTU
260 Ft3/Hr
260,000 BTU
NG 3.5* to 7”
LP 11” - 14”
NG 3.5* to 7”
LP 11” - 14”
NG 3.5* to 7”
LP 11” - 14”
12 Volt DC
12 Volt DC
12 Volt DC
540 CCA/800 CCA
540 CCA / 630 CCA
540 CCA / 630 CCA
Wet Lead Acid
Wet Lead Acid
Wet Lead Acid
Top Post Mount
Top Post Type
Top Post Type
10.25”L x 6.8”W x 8.9” H
BCI size 26 (BCI size 75 cold start, less than
32°F)
BCI size 26 (BCI size 75 cold start, less than
32°F)
627cc Briggs & Stratton Vanguard™
993 cc Briggs & Stratton Commercial Vanguard™ V-Twin
2 Cylinder - 4 Cycle
2 Cylinder - 4 Cycle
2 Cylinder - 4 Cycle
3600
3600
3600
Yes
Yes
Yes
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
34
Technical Specifications
Commercial Standby Generators
MG2524011BS
25kW
MG3524011BS
35kW
25,000W (LP) / 25,000W (NG)
35,000W (LP) / 31,500W (NG)
125
175
104.2 / 104.2
146 / 131
120/240V AC, Single Phase, 1.0
120/240V AC, Single Phase, 1.0 pf
Brushless
Brushless
Harmonic Distortion
Less than 5%
Less than 5%
Voltage Regulation
Automatic
Automatic
Propane (LP), Natural Gas
Propane (LP), Natural Gas
65dB
68dB
Full Pressure Lubrication
Yes
Yes
Overcrank Protection
Yes
Yes
70 x 32 x 37
84.4 x 39.5 x 42.5
MODEL NUMBER
Watts LP/NG
Main Breaker (Amps)
Amps LP/NG
Voltage
Alternator
Fuel Type
Sound Rating (at 7 Meters)
Dimensions (in inches: L x W x H)
Weight (Generator Only)
1,056
1,469
Horizontal
Horizontal
4 year P/L (limited)
4 year P/L (limited)
No
No
Engine Block Heater
MG627001 (sold separately)
MG624101 (sold separately)
Maintenance Kit
MG626801 (sold separately)
MG300022 (sold separately)
Hour Meter, Battery Charger, and
API SL 10W-30 Oil
Hour Meter, Battery Charger, and
API SL 10W-30 Oil
Fuel Consumption | LP
(at 1⁄2 load)
262,500 BTU/Hr
105 Ft. 3/Hr
2.9 Gal/Hr
292,900 BTU/Hr
117 Ft. 3/Hr
3.1 Gal/Hr
Fuel Consumption | NG
(at 1⁄2 load)
252,000 BTU/Hr
252 Ft3/H
282,000 BTU/Hr
282 Ft3/Hr
Fuel Consumption | LP
(at full load)
387,000 BTU/Hr
155 Ft3/Hr
4.3 Gal/Hr
465,100 BTU/Hr
186 Ft3/Hr
4.9 Gal/Hr
Fuel Consumption | NG
(at full load)
368,100 BTU/Hr
368 Ft3/Hr
458,800 BTU/Hr
458 Ft3/Hr
NG + LP 5” to 11”
NG + LP 7” to 11”
12 Volt DC
12 Volt DC
650 CCA
650 CCA
Orientation
Limited Warranty*
NFPA-37 Compliant
Turnkey Extras Included
FUEL CHARACTERISTICS
Water Pressure
BATTERY REQUIREMENTS
Volts (standard/cold start)
Minimum AMPS (standard/cold start)
Type
VRLA (Valve Regulated Lead Acid)
VRLA (Valve Regulated Lead Acid)
Terminal Hardware
Top Post Type
Top Post Type
Dimensions (Max)
7.5” x 11.25” x 10.0”
7.5” x 11.25” x 10.0”
Engine
Briggs & StrattonTM 1.6L
GM VortecTM 3.0L Industrial Powertrain
Cylinders
Inline 4 Cylinder, 4-Cycle
Inline 4 Cylinder, 4-Cycle
3600
1800
Yes
Yes
ENGINE SPECIFICATIONS
Operating RPM
California Compliant
These generators are rated in accordance with UL 2200 and CSA Standard C22.2 No. 100-04. Fuel consumption rates are estimated based on normal operating conditions. Generator operation may be greatly affected by elevation and the cycling
operation of multiple electrical appliances - fuel flow rates may vary depending on these factors. Installations must strictly comply with all applicable codes, industry standards, laws and regulations, installation manual. Other Generator/Automatic
Transfer Switch manufacturers products are not compatible with Milbank Home Generator Systems. Improper installation voids all warranty. Milbank reserves the right to make changes in specifications and features shown without notice or discontinue the product described at any time without notice or obligation.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
35
Technical Specifications
MG3520831WIN
35kW
MG3524031WIN
35kW
MG3524031DIN
35kW
35,000W (LP) / 31,500W (NG)
35,000W (LP) / 31,500W (NG)
35,000W (LP) / 31,500W (NG)
150
125
125
121 / 109
105 / 95
105 / 95
120/208V AC, 3-Phase, 0.8 pf
139/240V AC, 3-Phase, 0.8 pf
120/240V AC, 3--Phase, 0.8 pf
Brushless
Brushless
Brushless
Less than 5%
Less than 5%
Less than 5%
Automatic
Automatic
Automatic
Propane (LP), Natural Gas
Propane (LP), Natural Gas
Propane (LP), Natural Gas
68dB
68dB
68dB
Yes
Yes
Yes
Yes
Yes
Yes
84.4 x 39.5 x 42.5
84.4 x 39.5 x 42.5
84.4 x 39.5 x 42.5
1,469
1,469
1,469
Horizontal
Horizontal
Horizontal
4 year P/L (limited)
4 year P/L (limited)
4 year P/L (limited)
No
No
No
MG624101 (sold separately)
MG624101 (sold separately)
MG624101 (sold separately)
MG300022 (sold separately)
MG300022 (sold separately)
MG300022 (sold separately)
Hour Meter, Battery Charger, and
API SL 10W-30 Oil
Hour Meter, Battery Charger, and
API SL 10W-30 Oil
Hour Meter, Battery Charger, and
API SL 10W-30 Oil
292,900 BTU/Hr
117 Ft. 3/Hr
3.1 Gal/Hr
292,900 BTU/Hr
117 Ft. 3/Hr
3.1 Gal/Hr
292,900 BTU/Hr
117 Ft. 3/Hr
3.1 Gal/Hr
282,000 BTU/Hr
282 Ft3/Hr
282,000 BTU/Hr
282 Ft3/Hr
282,000 BTU/Hr
282 Ft3/Hr
465,100 BTU/Hr
186 Ft3/Hr
4.9 Gal/Hr
465,100 BTU/Hr
186 Ft3/Hr
4.9 Gal/Hr
465,100 BTU/Hr
186 Ft3/Hr
4.9 Gal/Hr
458,800 BTU/Hr
458 Ft3/Hr
458,800 BTU/Hr
458 Ft3/Hr
458,800 BTU/Hr
458 Ft3/Hr
NG + LP 7” to 11”
NG + LP 7” to 11”
NG + LP 7” to 11”
12 Volt DC
12 Volt DC
12 Volt DC
650 CCA
650 CCA
650 CCA
VRLA (Valve Regulated Lead Acid)
VRLA (Valve Regulated Lead Acid)
VRLA (Valve Regulated Lead Acid)
Top Post Type
Top Post Type
Top Post Type
7.5” x 11.25” x 10.0”
7.5” x 11.25” x 10.0”
7.5” x 11.25” x 10.0”
GM VortecTM 3.0L Industrial Powertrain
GM VortecTM 3.0L Industrial Powertrain
GM VortecTM 3.0L Industrial Powertrain
Inline 4 Cylinder, 4-Cycle
Inline 4 Cylinder, 4-Cycle
Inline 4 Cylinder, 4-Cycle
1800
1800
1800
Yes
Yes
Yes
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
36
Technical Specifications
Commercial Standby Generators
MODEL NUMBER
Watts LP/NG
Main Breaker (Amps)
Amps LP/NG
MG3548031WIN
35kW
MG3524011IL
35kW
35,000W (LP) / 31,500 (NG)
35,000W (LP) / 31,500 (NG)
60
175
61/55
146/131
277/480V AC, 3-Phase, 0.8 pf
120/240V AC, Single Phase, 1.0 pf
Brushless
Brushless
Harmonic Distortion
Less than 5%
Less than 5%
Voltage Regulation
Automatic
Automatic
Propane (LP), Natural Gas
Propane (LP), Natural Gas
68dB
68dB
Full Pressure Lubrication
Yes
Yes
Overcrank Protection
Yes
Yes
84.4" x 39.5" x 42.5"
84.4" x 39.5" x 42.5"
1,469
1,469
Horizontal
Horizontal
4 year P/L (Limited)
4 year P/L (Limited)
Voltage
Alternator
Fuel Type
Sound Rating (at 7 Meters)
Dimensions (in inches: L x W x H)
Weight (Generator Only)
Orientation
Limited Warranty*
NFPA-37 Compliant
No
No
Engine Block Heater
MG624101
MG624101
Maintenance Kit
MG300022
MG300022
Hour Meter, Battery Charger, Steel Base, External Automatic
Shut-off Valve, Low Pressure Regulator, Thermally Protected
Fuel System, Radiator Fluid, Synthetic Oil
Hour Meter, Battery Charger, Steel Base, External Automatic Shut-off
Valve, Low Pressure Regulator, Thermally Protected Fuel System,
Radiator Fluid, Synthetic Oil
Fuel Consumption | LP
(at 1⁄2 load)
292,900 BTU/Hr
117 Ft. 3/Hr
3.1 Gal/Hr
292,900 BTU/Hr
117 Ft. 3/Hr
3.1 Gal/Hr
Fuel Consumption | NG
(at 1⁄2 load)
282,000 BTU/Hr
282 Ft3/Hr
282,000 BTU/Hr
282 Ft3/Hr
Fuel Consumption | LP
(at full load)
465,100 BTU/Hr
186 Ft3/Hr 4.9 Gal/Hr
465,100 BTU/Hr
186 Ft3/Hr 4.9 Gal/Hr
Fuel Consumption | NG
(at full load)
458,800 BTU/Hr
458 Ft3/Hr
458,800 BTU/Hr
458 Ft3/Hr
Water Pressure
NG + LP 7 to 11”
NG + LP 7 to 11”
12 Volt DC
12 Volt DC
650 CCA
650 CCA
Turnkey Extras Included
FUEL CHARACTERISTICS
BATTERY REQUIREMENTS
Volts (standard/cold start)
Minimum AMPS (standard/cold start)
Type
Lead Acid
Lead Acid
Terminal Hardware
Top Post Type
Top Post Type
Dimensions (Max)
7.5"W x 11.25"L x 10"H
7.5"W x 11.25"L x 10"H
GM Vortec 3.0L
GM Vortec 3.0L
4 Cylinder, 4-Cycle
4 Cylinder, 4-Cycle
1,800
1,800
Yes
Yes
ENGINE SPECIFICATIONS
Engine
Cylinders
Operating RPM
California Compliant
These generators are rated in accordance with UL 2200 and CSA Standard C22.2 No. 100-04. Fuel consumption rates are estimated based on normal operating conditions. Generator operation may be
greatly affected by elevation and the cycling operation of multiple electrical appliances - fuel flow rates may vary depending on these factors. Installations must strictly comply with all applicable codes,
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
37
Technical Specifications
MG3520831WIL
35kW
MG3524031WIL
35kW
MG3524031DIL
35kW
35,000W (LP) / 31,500 (NG)
35,000W (LP) / 31,500 (NG)
35,000W (LP) / 31,500 (NG)
150
125
125
150
105/95
105/95
120/208V AC, 3-Phase, 0.8 pf
139/240V AC, 3-Phase, 0.8 pf
120/240V AC, 3-Phase, 0.8 pf
Brushless
Brushless
Brushless
Less than 5%
Less than 5%
Less than 5%
Automatic
Automatic
Automatic
Propane (LP), Natural Gas
Propane (LP), Natural Gas
Propane (LP), Natural Gas
68dB
68dB
68dB
Yes
Yes
Yes
Yes
Yes
Yes
84.4" x 39.5" x 42.5"
84.4" x 39.5" x 42.5"
84.4" x 39.5" x 42.5"
1,469
1,469
1,469
Horizontal
Horizontal
Horizontal
4 year P/L (Limited)
4 year P/L (Limited)
4 year P/L (Limited)
No
No
No
MG624101
MG624101
MG624101
MG300022
MG300022
MG300022
Hour Meter, Battery Charger, Steel Base, External Automatic Shut-off Valve, Low Pressure
Hour Meter, Battery Charger, Steel Base, External Automatic Shut-off Valve, Low Pressure
Hour Meter, Battery Charger, Steel Base, External Automatic Shut-off Valve, Low Pressure
292,900 BTU/Hr
117 Ft. 3/Hr
3.1 Gal/Hr
292,900 BTU/Hr
117 Ft. 3/Hr
3.1 Gal/Hr
292,900 BTU/Hr
117 Ft. 3/Hr
3.1 Gal/Hr
282,000 BTU/Hr
282 Ft3/Hr
282,000 BTU/Hr
282 Ft3/Hr
282,000 BTU/Hr
282 Ft3/Hr
465,100 BTU/Hr
186 Ft3/Hr 4.9 Gal/Hr
465,100 BTU/Hr
186 Ft3/Hr 4.9 Gal/Hr
465,100 BTU/Hr
186 Ft3/Hr 4.9 Gal/Hr
458,800 BTU/Hr
458 Ft3/Hr
458,800 BTU/Hr
458 Ft3/Hr
458,800 BTU/Hr
458 Ft3/Hr
NG + LP 7 to 11”
NG + LP 7 to 11”
NG + LP 7 to 11”
12 Volt DC
12 Volt DC
12 Volt DC
650 CCA
650 CCA
650 CCA
Lead Acid
Lead Acid
Lead Acid
Top Post Type
Top Post Type
Top Post Type
7.5"W x 11.25"L x 10"H
7.5"W x 11.25"L x 10"H
7.5"W x 11.25"L x 10"H
GM Vortec 3.0L
GM Vortec 3.0L
GM Vortec 3.0L
4 Cylinder, 4-Cycle
4 Cylinder, 4-Cycle
4 Cylinder, 4-Cycle
1,800
1,800
1,800
Yes
Yes
Yes
industry standards, laws and regulations, installation manual. Other Generator/Automatic Transfer Switch manufacturers products are not compatible with Milbank Home Generator Systems. Improper
installation voids all warranty. Milbank reserves the right to make changes in specifications and features shown without notice or discontinue the product described at any time without notice or obligation.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
38
Technical Specifications
Commercial Standby Generators
MODEL NUMBER
Watts LP/NG
Main Breaker (Amps)
Amps LP/NG
Voltage
Alternator
Harmonic Distortion
Voltage Regulation
Fuel Type
Sound Rating (at 7 Meters)
Full Pressure Lubrication
Overcrank Protection
Dimensions (in inches: L x W x H)
Weight (Generator Only)
Orientation
Limited Warranty*
MG3548031WIL
35kW
MG4824011BS
48kW
35,000W (LP) / 31,500 (NG)
48,000 (LP) / 43,200 (NG)
60
225
61/55
200/180
277/480V AC, 3-Phase, 0.8 pf
120/240V AC, Single Phase, 1.0 pf
Brushless
Brushless
Less than 5%
Less than 5%
Automatic
Automatic
Propane (LP), Natural Gas
Propane (LP), Natural Gas
68dB
66dB
Yes
Yes
Yes
Yes
84.4" x 39.5" x 42.5"
98.5" x 39.5" x 44"
1,469
1890
Horizontal
Horizontal
4 year P/L (Limited)
4 year P/L (Limited)
NFPA-37 Compliant
No
No
Engine Block Heater
MG624101
MG624101
Maintenance Kit
MG300022
MG300022
Hour Meter, Battery Charger, Steel Base, External Automatic
Shut-off Valve, Low Pressure Regulator, Thermally Protected
Fuel System, Radiator Fluid, Synthetic Oil
Hour Meter, Battery Charger, Steel Base, External Automatic Shut-off
Valve, Low Pressure Regulator, Thermally Protected Fuel System, Radiator Fluid, Synthetic Oil
Fuel Consumption | LP
(at 1⁄2 load)
292,900 BTU/Hr
117 Ft. 3/Hr
3.1 Gal/Hr
462,500 BTU/Hr
185 Ft3/Hr
4.8 Gal/Hr
Fuel Consumption | NG
(at 1⁄2 load)
282,000 BTU/Hr
282 Ft3/Hr
429,000 BTU/Hr
429 Ft3/Hr
Fuel Consumption | LP
(at full load)
465,100 BTU/Hr
186 Ft3/Hr 4.9 Gal/Hr
785,000 BTU/Hr
314 Ft3/Hr 8.2 Gal/Hr
Fuel Consumption | NG
(at full load)
458,800 BTU/Hr
458 Ft3/Hr
717,000 BTU/Hr
717 Ft3/Hr
Water Pressure
NG + LP 7 to 11”
NG + LP 7 to 11”
12 Volt DC
12 Volt DC
Turnkey Extras Included
FUEL CHARACTERISTICS
BATTERY REQUIREMENTS
Volts (standard/cold start)
Minimum AMPS (standard/cold start)
650 CCA
650 CCA
Type
Lead Acid
Lead Acid
Terminal Hardware
Top Post Type
Top Post Type
Dimensions (Max)
7.5"W x 11.25"L x 10"H
7.5"W x 11.25"L x 10"H
GM Vortec 3.0L
GM Vortec 5.0L
4 Cylinder, 4-Cycle
8 Cylinder, 4-Cycle
1,800
1,800
Yes
Yes
ENGINE SPECIFICATIONS
Engine
Cylinders
Operating RPM
California Compliant
These generators are rated in accordance with UL 2200 and CSA Standard C22.2 No. 100-04. Fuel consumption rates are estimated based on normal operating conditions. Generator operation may be greatly affected by elevation and the cycling
operation of multiple electrical appliances - fuel flow rates may vary depending on these factors. Installations must strictly comply with all applicable codes, industry standards, laws and regulations, installation manual. Other Generator/Automatic
Transfer Switch manufacturers products are not compatible with Milbank Home Generator Systems. Improper installation voids all warranty. Milbank reserves the right to make changes in specifications and features shown without notice or discontinue the product described at any time without notice or obligation.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
39
Technical Specifications
MG4820831WIN
48kW
MG4824031WIN
48kW
MG4824031DIN
48kW
48,000 (LP) / 43,200 (NG)
48,000 (LP) / 43,200 (NG)
48,000 (LP) / 43,200 (NG)
200
175
175
167/150
144/140
144/140
120/208V AC, 3-Phase, 0.8 pf
139/240V AC, 3-Phase, 0.8 pf
120/240V AC, 3-Phase, 0.8 pf
Brushless
Brushless
Brushless
Less than 5%
Less than 5%
Less than 5%
Automatic
Automatic
Automatic
Propane (LP), Natural Gas
Propane (LP), Natural Gas
Propane (LP), Natural Gas
66dB
66dB
66dB
Yes
Yes
Yes
Yes
Yes
Yes
98.5" x 39.5" x 44"
98.5" x 39.5" x 44"
98.5" x 39.5" x 44"
1890
1890
1890
Horizontal
Horizontal
Horizontal
4 year P/L (Limited)
4 year P/L (Limited)
4 year P/L (Limited)
No
No
No
MG624101
MG624101
MG624101
MG300022
MG300022
MG300022
Hour Meter, Battery Charger, Steel Base, External Automatic Shut-off Valve, Low Pressure
Hour Meter, Battery Charger, Steel Base, External Automatic Shut-off Valve, Low Pressure
Hour Meter, Battery Charger, Steel Base, External Automatic Shut-off Valve, Low Pressure
462,500 BTU/Hr
185 Ft3/Hr
4.8 Gal/Hr
462,500 BTU/Hr
185 Ft3/Hr
4.8 Gal/Hr
462,500 BTU/Hr
185 Ft3/Hr
4.8 Gal/Hr
429,000 BTU/Hr
429 Ft3/Hr
429,000 BTU/Hr
429 Ft3/Hr
429,000 BTU/Hr
429 Ft3/Hr
785,000 BTU/Hr
314 Ft3/Hr 8.2 Gal/Hr
785,000 BTU/Hr
314 Ft3/Hr 8.2 Gal/Hr
785,000 BTU/Hr
314 Ft3/Hr 8.2 Gal/Hr
717,000 BTU/Hr
717 Ft3/Hr
717,000 BTU/Hr
717 Ft3/Hr
717,000 BTU/Hr
717 Ft3/Hr
NG + LP 7 to 11”
NG + LP 7 to 11”
NG + LP 7 to 11”
12 Volt DC
12 Volt DC
12 Volt DC
650 CCA
650 CCA
650 CCA
Lead Acid
Lead Acid
Lead Acid
Top Post Type
Top Post Type
Top Post Type
7.5"W x 11.25"L x 10"H
7.5"W x 11.25"L x 10"H
7.5"W x 11.25"L x 10"H
GM Vortec 5.0L
GM Vortec 5.0L
GM Vortec 5.0L
8 Cylinder, 4-Cycle
8 Cylinder, 4-Cycle
8 Cylinder, 4-Cycle
1,800
1,800
1,800
Yes
Yes
Yes
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
40
Technical Specifications
Commercial Standby Generators
MG4848031WIN
48kW
MG4824011IL
48kW
48,000 (LP) / 43,200 (NG)
48,000 (LP) / 43,200 (NG)
90
225
73/65
200/180
277/480V AC, 3-Phase, 0.8 pf
120/240V AC, Single Phase, 1.0 pf
Brushless
Brushless
Harmonic Distortion
Less than 5%
Less than 5%
Voltage Regulation
Automatic
Automatic
Propane (LP), Natural Gas
Propane (LP), Natural Gas
66dB
66dB
Full Pressure Lubrication
Yes
Yes
Overcrank Protection
Yes
Yes
98.5" x 39.5" x 44"
98.5" x 39.5" x 44"
1890
1890
Horizontal
Horizontal
4 year P/L (Limited)
4 year P/L (Limited)
NFPA-37 Compliant
No
No
Engine Block Heater
MG624101
MG624101
Maintenance Kit
MG300022
MG300022
Hour Meter, Battery Charger, Steel Base, External Automatic
Shut-off Valve, Low Pressure Regulator, Thermally Protected
Fuel System, Radiator Fluid, Synthetic Oil
Hour Meter, Battery Charger, Steel Base, External Automatic Shut-off
Valve, Low Pressure Regulator, Thermally Protected Fuel System, Radiator Fluid, Synthetic Oil
Fuel Consumption | LP
(at 1⁄2 load)
462,500 BTU/Hr
185 Ft3/Hr
4.8 Gal/Hr
462,500 BTU/Hr
185 Ft3/Hr
4.8 Gal/Hr
Fuel Consumption | NG
(at 1⁄2 load)
429,000 BTU/Hr
429 Ft3/Hr
429,000 BTU/Hr
429 Ft3/Hr
Fuel Consumption | LP
(at full load)
785,000 BTU/Hr
314 Ft3/Hr 8.2 Gal/Hr
785,000 BTU/Hr
314 Ft3/Hr 8.2 Gal/Hr
Fuel Consumption | NG
(at full load)
717,000 BTU/Hr
717 Ft3/Hr
717,000 BTU/Hr
717 Ft3/Hr
Water Pressure
NG + LP 7 to 11”
NG + LP 7 to 11”
12 Volt DC
12 Volt DC
MODEL NUMBER
Watts LP/NG
Main Breaker (Amps)
Amps LP/NG
Voltage
Alternator
Fuel Type
Sound Rating (at 7 Meters)
Dimensions (in inches: L x W x H)
Weight (Generator Only)
Orientation
Limited Warranty*
Turnkey Extras Included
FUEL CHARACTERISTICS
BATTERY REQUIREMENTS
Volts (standard/cold start)
Minimum AMPS (standard/cold start)
650 CCA
650 CCA
Type
Lead Acid
Lead Acid
Terminal Hardware
Top Post Type
Top Post Type
Dimensions (Max)
7.5"W x 11.25"L x 10"H
7.5"W x 11.25"L x 10"H
GM Vortec 5.0L
GM Vortec 5.0L
8 Cylinder, 4-Cycle
8 Cylinder, 4-Cycle
1,800
1,800
Yes
Yes
ENGINE SPECIFICATIONS
Engine
Cylinders
Operating RPM
California Compliant
These generators are rated in accordance with UL 2200 and CSA Standard C22.2 No. 100-04. Fuel consumption rates are estimated based on normal operating conditions. Generator operation may be greatly affected by elevation and the cycling
operation of multiple electrical appliances - fuel flow rates may vary depending on these factors. Installations must strictly comply with all applicable codes, industry standards, laws and regulations, installation manual. Other Generator/Automatic
Transfer Switch manufacturers products are not compatible with Milbank Home Generator Systems. Improper installation voids all warranty. Milbank reserves the right to make changes in specifications and features shown without notice or discontinue the product described at any time without notice or obligation.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
41
Technical Specifications
MG4820831WIL
48kW
MG4824031WIL
48kW
MG4824031DIL
48kW
48,000 (LP) / 43,200 (NG)
48,000 (LP) / 43,200 (NG)
48,000 (LP) / 43,200 (NG)
200
175
175
167/150
144/140
144/140
120/208V AC, 3-Phase, 0.8 pf
139/240V AC, 3-Phase, 0.8 pf
120/240V AC, 3-Phase, 0.8 pf
Brushless
Brushless
Brushless
Less than 5%
Less than 5%
Less than 5%
Automatic
Automatic
Automatic
Propane (LP), Natural Gas
Propane (LP), Natural Gas
Propane (LP), Natural Gas
66dB
66dB
66dB
Yes
Yes
Yes
Yes
Yes
Yes
98.5" x 39.5" x 44"
98.5" x 39.5" x 44"
98.5" x 39.5" x 44"
1890
1890
1890
Horizontal
Horizontal
Horizontal
4 year P/L (Limited)
4 year P/L (Limited)
4 year P/L (Limited)
No
No
No
MG624101
MG624101
MG624101
MG300022
MG300022
MG300022
Hour Meter, Battery Charger, Steel Base, External Automatic Shut-off Valve, Low Pressure
Hour Meter, Battery Charger, Steel Base, External Automatic Shut-off Valve, Low Pressure
Hour Meter, Battery Charger, Steel Base, External Automatic Shut-off Valve, Low Pressure
462,500 BTU/Hr
185 Ft3/Hr
4.8 Gal/Hr
462,500 BTU/Hr
185 Ft3/Hr
4.8 Gal/Hr
462,500 BTU/Hr
185 Ft3/Hr
4.8 Gal/Hr
429,000 BTU/Hr
429 Ft3/Hr
429,000 BTU/Hr
429 Ft3/Hr
429,000 BTU/Hr
429 Ft3/Hr
785,000 BTU/Hr
314 Ft3/Hr 8.2 Gal/Hr
785,000 BTU/Hr
314 Ft3/Hr 8.2 Gal/Hr
785,000 BTU/Hr
314 Ft3/Hr 8.2 Gal/Hr
717,000 BTU/Hr
717 Ft3/Hr
717,000 BTU/Hr
717 Ft3/Hr
717,000 BTU/Hr
717 Ft3/Hr
NG + LP 7 to 11”
NG + LP 7 to 11”
NG + LP 7 to 11”
12 Volt DC
12 Volt DC
12 Volt DC
650 CCA
650 CCA
650 CCA
Lead Acid
Lead Acid
Lead Acid
Top Post Type
Top Post Type
Top Post Type
7.5"W x 11.25"L x 10"H
7.5"W x 11.25"L x 10"H
7.5"W x 11.25"L x 10"H
GM Vortec 5.0L
GM Vortec 5.0L
GM Vortec 5.0L
8 Cylinder, 4-Cycle
8 Cylinder, 4-Cycle
8 Cylinder, 4-Cycle
1,800
1,800
1,800
Yes
Yes
Yes
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
42
Technical Specifications
Commercial Standby Generators
MG4848031WIL
48kW
MG6024011BS
60kW
48,000 (LP) / 43,200 (NG)
60,000 (LP) / 54,000 (NG)
90
300
73/65
250/225
277/480V AC, 3-Phase, 0.8 pf
120/240V AC, Single Phase, 1.0 pf
Brushless
Brushless
Harmonic Distortion
Less than 5%
Less than 5%
Voltage Regulation
Automatic
Automatic
Propane (LP), Natural Gas
Propane (LP), Natural Gas
66dB
66dB
Full Pressure Lubrication
Yes
Yes
Overcrank Protection
Yes
Yes
98.5" x 39.5" x 44"
98.5" x 39.5" x 44"
1890
1890
Horizontal
Horizontal
4 year P/L (Limited)
4 year P/L (Limited)
NFPA-37 Compliant
No
No
Engine Block Heater
MG624101
MG624201
Maintenance Kit
MG300022
MG450022
Hour Meter, Battery Charger, Steel Base, External Automatic
Shut-off Valve, Low Pressure Regulator, Thermally Protected
Fuel System, Radiator Fluid, Synthetic Oil
Hour Meter, Battery Charger, Steel Base, External Automatic Shut-off
Valve, Low Pressure Regulator, Thermally Protected Fuel System, Radiator Fluid, Synthetic Oil
Fuel Consumption | LP
(at 1⁄2 load)
462,500 BTU/Hr
185 Ft3/Hr
4.8 Gal/Hr
500,000 BTU/Hr
200 Ft3/Hr
5.2 Gal/Hr
Fuel Consumption | NG
(at 1⁄2 load)
429,000 BTU/Hr
429 Ft3/Hr
463,000 BTU/Hr
463 Ft3/Hr
Fuel Consumption | LP
(at full load)
785,000 BTU/Hr
314 Ft3/Hr 8.2 Gal/Hr
762,500 BTU/Hr
345 Ft3/Hr 9 Gal/Hr
Fuel Consumption | NG
(at full load)
717,000 BTU/Hr
717 Ft3/Hr
788,000 BTU/Hr
788 Ft3/Hr
Water Pressure
NG + LP 7 to 11”
NG + LP 7 to 11”
12 Volt DC
12 Volt DC
650 CCA
650 CCA
MODEL NUMBER
Watts LP/NG
Main Breaker (Amps)
Amps LP/NG
Voltage
Alternator
Fuel Type
Sound Rating (at 7 Meters)
Dimensions (in inches: L x W x H)
Weight (Generator Only)
Orientation
Limited Warranty*
Turnkey Extras Included
FUEL CHARACTERISTICS
BATTERY REQUIREMENTS
Volts (standard/cold start)
Minimum AMPS (standard/cold start)
Type
Lead Acid
Lead Acid
Terminal Hardware
Top Post Type
Top Post Type
Dimensions (Max)
7.5"W x 11.25"L x 10"H
7.5"W x 11.25"L x 10"H
GM Vortec 5.0L
GM Vortec 5.7L
8 Cylinder, 4-Cycle
8 Cylinder, 4-Cycle
1,800
1,800
Yes
Yes
ENGINE SPECIFICATIONS
Engine
Cylinders
Operating RPM
California Compliant
These generators are rated in accordance with UL 2200 and CSA Standard C22.2 No. 100-04. Fuel consumption rates are estimated based on normal operating conditions. Generator operation may be greatly affected by elevation and the cycling
operation of multiple electrical appliances - fuel flow rates may vary depending on these factors. Installations must strictly comply with all applicable codes, industry standards, laws and regulations, installation manual. Other Generator/Automatic
Transfer Switch manufacturers products are not compatible with Milbank Home Generator Systems. Improper installation voids all warranty. Milbank reserves the right to make changes in specifications and features shown without notice or discontinue the product described at any time without notice or obligation.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
43
Technical Specifications
MG6220831WIN
62kW
MG6224031WIN
62kW
MG6224031DIN
62kW
62,000 (LP) / 55,800 (NG)
62,000 (LP) / 55,800 (NG)
62,000 (LP) / 55,800 (NG)
225
225
225
215/194
186/168
186/168
120/208V AC, 3-Phase, 0.8 pf
139/240V AC, 3-Phase, 0.8 pf
120/240V AC, 3-Phase, 0.8 pf
Brushless
Brushless
Brushless
Less than 5%
Less than 5%
Less than 5%
Automatic
Automatic
Automatic
Propane (LP), Natural Gas
Propane (LP), Natural Gas
Propane (LP), Natural Gas
66dB
66dB
66dB
Yes
Yes
Yes
Yes
Yes
Yes
98.5" x 39.5" x 44"
98.5" x 39.5" x 44"
98.5" x 39.5" x 44"
1890
1890
1890
Horizontal
Horizontal
Horizontal
4 year P/L (Limited)
4 year P/L (Limited)
4 year P/L (Limited)
No
No
No
MG624201
MG624201
MG624201
MG450022
MG450022
MG450022
Hour Meter, Battery Charger, Steel Base, External Automatic Shut-off Valve, Low Pressure
Hour Meter, Battery Charger, Steel Base, External Automatic Shut-off Valve, Low Pressure
Hour Meter, Battery Charger, Steel Base, External Automatic Shut-off Valve, Low Pressure
500,000 BTU/Hr
200 Ft3/Hr
5.2 Gal/Hr
500,000 BTU/Hr
200 Ft3/Hr
5.2 Gal/Hr
500,000 BTU/Hr
200 Ft3/Hr
5.2 Gal/Hr
463,000 BTU/Hr
463 Ft3/Hr
463,000 BTU/Hr
463 Ft3/Hr
463,000 BTU/Hr
463 Ft3/Hr
762,500 BTU/Hr
345 Ft3/Hr 9 Gal/Hr
762,500 BTU/Hr
345 Ft3/Hr 9 Gal/Hr
762,500 BTU/Hr
345 Ft3/Hr 9 Gal/Hr
788,000 BTU/Hr
788 Ft3/Hr
788,000 BTU/Hr
788 Ft3/Hr
788,000 BTU/Hr
788 Ft3/Hr
NG + LP 7 to 11”
NG + LP 7 to 11”
NG + LP 7 to 11”
12 Volt DC
12 Volt DC
12 Volt DC
650 CCA
650 CCA
650 CCA
Lead Acid
Lead Acid
Lead Acid
Top Post Type
Top Post Type
Top Post Type
7.5"W x 11.25"L x 10"H
7.5"W x 11.25"L x 10"H
7.5"W x 11.25"L x 10"H
GM Vortec 5.7L
GM Vortec 5.7L
GM Vortec 5.7L
8 Cylinder, 4-Cycle
8 Cylinder, 4-Cycle
8 Cylinder, 4-Cycle
1,800
1,800
1,800
Yes
Yes
Yes
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
44
Technical Specifications
Commercial Standby Generators
MG6248031WIN
62kW
MG6248031WIN
60kW
62,000 (LP) / 55,800 (NG)
60,000 (LP) / 54,000 (NG)
110
300
93/84
250/225
277/480V AC, 3-Phase, 0.8 pf
120/240V AC, Single Phase, 1.0 pf
Brushless
Brushless
Harmonic Distortion
Less than 5%
Less than 5%
Voltage Regulation
Automatic
Automatic
Propane (LP), Natural Gas
Propane (LP), Natural Gas
66dB
66dB
Full Pressure Lubrication
Yes
Yes
Overcrank Protection
Yes
Yes
98.5" x 39.5" x 44"
98.5" x 39.5" x 44"
MODEL NUMBER
Watts LP/NG
Main Breaker (Amps)
Amps LP/NG
Voltage
Alternator
Fuel Type
Sound Rating (at 7 Meters)
Dimensions (in inches: L x W x H)
Weight (Generator Only)
Orientation
Limited Warranty*
NFPA-37 Compliant
1890
1890
Horizontal
Horizontal
4 year P/L (Limited)
4 year P/L (Limited)
No
No
Engine Block Heater
MG624201
MG624201
Maintenance Kit
MG450022
MG450022
Hour Meter, Battery Charger, Steel Base, External
Automatic Shut-off Valve, Low Pressure Regulator,
Thermally Protected Fuel System, Radiator Fluid,
Synthetic Oil
Hour Meter, Battery Charger, Steel Base, External
Automatic Shut-off Valve, Low Pressure Regulator,
Thermally Protected Fuel System, Radiator Fluid,
Synthetic Oil
Fuel Consumption | LP
(at 1⁄2 load)
500,000 BTU/Hr
200 Ft3/Hr
5.2 Gal/Hr
500,000 BTU/Hr
200 Ft3/Hr
5.2 Gal/Hr
Fuel Consumption | NG
(at 1⁄2 load)
463,000 BTU/Hr
463 Ft3/Hr
463,000 BTU/Hr
463 Ft3/Hr
Fuel Consumption | LP
(at full load)
762,500 BTU/Hr
345 Ft3/Hr 9 Gal/Hr
762,500 BTU/Hr
345 Ft3/Hr 9 Gal/Hr
Fuel Consumption | NG
(at full load)
788,000 BTU/Hr
788 Ft3/Hr
788,000 BTU/Hr
788 Ft3/Hr
Water Pressure
NG + LP 7 to 11”
NG + LP 7 to 11”
12 Volt DC
12 Volt DC
Turnkey Extras Included
FUEL CHARACTERISTICS
BATTERY REQUIREMENTS
Volts (standard/cold start)
Minimum AMPS (standard/cold start)
650 CCA
650 CCA
Type
Lead Acid
Lead Acid
Terminal Hardware
Top Post Type
Top Post Type
Dimensions (Max)
7.5"W x 11.25"L x 10"H
7.5"W x 11.25"L x 10"H
GM Vortec 5.7L
GM Vortec 5.7L
8 Cylinder, 4-Cycle
8 Cylinder, 4-Cycle
1,800
1,800
Yes
Yes
ENGINE SPECIFICATIONS
Engine
Cylinders
Operating RPM
California Compliant
These generators are rated in accordance with UL 2200 and CSA Standard C22.2 No. 100-04. Fuel consumption rates are estimated based on normal operating conditions. Generator operation may be greatly affected by elevation and the cycling operation of
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
45
Technical Specifications
MG6220831WIL
62kW
MG6224031WIL
62kW
MG6224031DIL
62kW
MG6248031WIL
62kW
62,000 (LP) / 55,800 (NG)
62,000 (LP) / 55,800 (NG)
62,000 (LP) / 55,800 (NG)
62,000 (LP) / 55,800 (NG)
225
225
225
110
215/194
186/168
186/168
93/84
120/208V AC, 3-Phase, 0.8 pf
139/240V AC, 3-Phase, 0.8 pf
120/240V AC, 3-Phase, 0.8 pf
277/480V AC, 3-Phase, 0.8 pf
Brushless
Brushless
Brushless
Brushless
Less than 5%
Less than 5%
Less than 5%
Less than 5%
Automatic
Automatic
Automatic
Automatic
Propane (LP), Natural Gas
Propane (LP), Natural Gas
Propane (LP), Natural Gas
Propane (LP), Natural Gas
66dB
66dB
66dB
66dB
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
98.5" x 39.5" x 44"
98.5" x 39.5" x 44"
98.5" x 39.5" x 44"
98.5" x 39.5" x 44"
1890
1890
1890
1890
Horizontal
Horizontal
Horizontal
Horizontal
4 year P/L (Limited)
4 year P/L (Limited)
4 year P/L (Limited)
4 year P/L (Limited)
No
No
No
No
MG624201
MG624201
MG624201
MG624201
MG450022
MG450022
MG450022
MG450022
Hour Meter, Battery Charger, Steel
Base, External Automatic Shut-off
Valve, Low Pressure
Hour Meter, Battery Charger, Steel
Base, External Automatic Shut-off
Valve, Low Pressure
Hour Meter, Battery Charger, Steel
Base, External Automatic Shut-off
Valve, Low Pressure
Hour Meter, Battery Charger, Steel
Base, External Automatic Shut-off
Valve, Low Pressure
500,000 BTU/Hr
200 Ft3/Hr
5.2 Gal/Hr
500,000 BTU/Hr
200 Ft3/Hr
5.2 Gal/Hr
500,000 BTU/Hr
200 Ft3/Hr
5.2 Gal/Hr
500,000 BTU/Hr
200 Ft3/Hr
5.2 Gal/Hr
463,000 BTU/Hr
463 Ft3/Hr
463,000 BTU/Hr
463 Ft3/Hr
463,000 BTU/Hr
463 Ft3/Hr
463,000 BTU/Hr
463 Ft3/Hr
762,500 BTU/Hr
345 Ft3/Hr 9 Gal/Hr
762,500 BTU/Hr
345 Ft3/Hr 9 Gal/Hr
762,500 BTU/Hr
345 Ft3/Hr 9 Gal/Hr
762,500 BTU/Hr
345 Ft3/Hr 9 Gal/Hr
788,000 BTU/Hr
788 Ft3/Hr
788,000 BTU/Hr
788 Ft3/Hr
788,000 BTU/Hr
788 Ft3/Hr
788,000 BTU/Hr
788 Ft3/Hr
NG + LP 7 to 11”
NG + LP 7 to 11”
NG + LP 7 to 11”
12 Volt DC
12 Volt DC
12 Volt DC
12 Volt DC
650 CCA
650 CCA
650 CCA
650 CCA
Lead Acid
Lead Acid
Lead Acid
Lead Acid
Top Post Type
Top Post Type
Top Post Type
Top Post Type
7.5"W x 11.25"L x 10"H
7.5"W x 11.25"L x 10"H
7.5"W x 11.25"L x 10"H
7.5"W x 11.25"L x 10"H
GM Vortec 5.7L
GM Vortec 5.7L
GM Vortec 5.7L
GM Vortec 5.7L
8 Cylinder, 4-Cycle
8 Cylinder, 4-Cycle
8 Cylinder, 4-Cycle
8 Cylinder, 4-Cycle
1,800
1,800
1,800
1,800
Yes
Yes
Yes
Yes
multiple electrical appliances - fuel flow rates may vary depending on these factors. Installations must strictly comply with all applicable codes, industry standards, laws and regulations, installation manual. Other Generator/Automatic Transfer Switch manufacturers products
are not compatible with Milbank Home Generator Systems. Improper installation voids all warranty. Milbank reserves the right to make changes in specifications and features shown without notice or discontinue the product described at any time without notice or obligation.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
46
Technical Specifications
SynapSwitch™ & Other Transfer Switches,
Digital Inverter Generators
MODEL NUMBER
MATS10011
MATS15012
MATS20011
MATS20012
MATSRM50
Compatible
generator units
MG08001, MG10002
MG12002, MG17001
MG20003
MG08001, MG10002
MG12002, MG17001
MG20003
MG08001, MG10002
MG12002, MG17001
MG20003
MG3524011BS, MG4824011BS,
MG3524011IL, MG4824011IL,
MG2524011BS
MATS10011, MATS15012,
MATS20011, MATS20012
Phase
Single Phase 240V
Single Phase 240V
Single Phase 240V
Single Phase 240V
Single Phase 240V
3 years
3 years
3 Years
3 Years
3 Years
Whole House
Whole House
Whole House
Whole House
Individual Circuit
Limited Warranty
Circuits
Amps
100
150
200
200
Resistive 50 Amps;
Inductive 40 Amps
Service entrance
disconnect
Yes
Yes
Yes
Yes
No
6.54” x 18.25” x
27.15”
6.54” x 18.25” x
27.15”
6.54” x 18.25” x
27.15”
6.54” x 18.25” x 27.15”
8.2” x 5.2” x 3.4”
42 lbs.
42 lbs.
42 lbs.
42 lbs.
3.6 lbs.
Intelligent Synap
Technology
Yes
Yes
Yes
Yes
No
Accessory
(#MATSRM50)
Yes
Yes
Yes
Yes
No
Dimensions (L x W
x H)
Weight
MODEL NUMBER
MG0503120
Limited Warranty
MG1003002
MG2003002
MG4002001S2**
MG20003
MG3524011BS
MG4824011BS
MG3524011IL
MG4824011IL
MG2524011BS
MG6024011BS
MG6024011IL
MG0501440
MG08001
MG10002
MG08001
MG10002
MG12002
MG17001
MG20003
MG08001
MG10002
MG12002
MG17001
MG20003
MG08001
MG10002
MG12002
MG17001
MG20003
Single Phase 240V
Single Phase 240V
Single Phase 240V
Single Phase
240V
Single Phase 240V
3 Years
3 Years
3 Years
3 Years
3 Years
3 Years
Compatible
generator units
Phase
MG1003162
Power Management
Upgrade - used in
conjunction with:
MG1003162
MG1003002
MG2003002
Single Phase 240V
12
16
Whole House
Whole House
Whole House
(2) Central Air + (4)
50 Amp Relays + 2
low voltage lock outs
Amps
50A
100A
100A
200A
2 X 200A
N/A
Service entrance
disconnect
No
No
No
No
Yes
N/A
14.25” x 6” x 21”
14” x 6” x 24”
12" x 6" x 16"
12” x 6” x
22”
37” x 7” x 23.70”
12” x 6” x 22”
29 lbs.
39 lbs.
24 lbs.
37 lbs.
111 lbs.
64 lbs.
120/240 Voltage,
2 Poles, 60Hz,
NEMA 3R,
UL 1008 Listed
Intelligent Power
Management System
manages up to (4)
additional high
wattage appliances
for true wholehouse management.
NEMA 3R Enclosure,
UL1008 Listed
Circuits
Dimensions (L x W
x H)
Weight
Common features
Power management
120/240 Voltage, 2 Poles, 50/60 Frequency
NEMA 3R Enclosure, UL 1008 Listed
No
Patented Power Management
Technology Included
120/240
Voltage, 2
Poles,
50/60
Frequency
NEMA 3R
Enclosure, UL
1008 Listed
Patented Power Management Technology Included
*Must order part #MG07033 to be compatible (contact Milbank sales office for questions).
**Can only be ordered with a home standby generator.
Installer is required to review local codes prior to installation to determine if a transfer switch with separate service disconnect is required. All installations must strictly comply with all applicable codes,
industry standards, laws and regulations, installation manual. Other Generator/Automatic Transfer Switch manufacturers products are not compatible with Milbank Home Generator Systems. Improper
installation voids all warranty. Milbank reserves the right to make changes in specifications and features shown without notice or discontinue the product described at any time without notice or obligation.
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
47
Technical Specifications
MODEL NUMBER
MPG1000I
MPG2000IP
52cc
79cc
2 years
2 years
Low Oil Shutdown
Yes
Yes
Electrical Start (with battery)
No
No
Automatic Fuel Shut-Off
No
No
CARB Compliant Available
Yes
Yes
Running Watts
1000
1800
Starting Watts
1100
2200
Run Time @ 1/2 load
9 hrs
11 hrs
Sound Rating at 25% load
53 dbA
53 dbA
Sound Rating at 50% load
56 dbA
56 dbA
Cu
Cu
NEMA 5-15R (125vac 20A Duplex)
Qty - 2
Qty - 2
NEMA 5-20R (125vac 20A Duplex)
Qty - 0
Qty - 0
20 Amp push button circuit breakers
Qty - 0
Qty - 0
NEMA L14-30R (125/250VAC 30A Twist Lock)
Qty - 0
Qty - 0
12V DC Outlet
No
Yes
Oil Bottle (1 bottle sized for engine: SAE 10W30)
No
Yes
Oil Funnel
Yes
Yes
Shipping Weight
30 lbs
43 lbs
Parallel Capable
No
Yes
Engine Displacement
Warranty
Rotor Windings
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
48
Technical Specifications
Vigilant® & Manual Transfer Switches
MODEL NUMBER
Phase
MGVATS1001LC
MGVATS1001240
MGVATS2001240
MGVATS4001240
Single Phase 240V
Single Phase 240V
Single Phase 240V
Single Phase 240V
(add’l voltages available)
5 years
5 years
5 years
5 Years
Limited Warranty
Circuits
N/A
N/A
N/A
N/A
Amps
100A
100A
200A
400A
No
No
No
No
16” x 14” x 6”
16” x 14” x 6”
24” x 20” x 6”
48” x 30” x 13”
25 lbs.
25 lbs.
55 lbs.
190 lbs.
120/240 Voltage, 2 Poles,
60Hz, External digital
display and LEDs, NEMA
3R, UL1008 Listed
120/240 Voltage, 2 Poles,
60Hz, External digital
display and LEDs, NEMA
3R, UL1008 Listed
120/240 Voltage, 2 Poles,
60Hz, External digital
display and LEDs, NEMA
3R, UL1008 Listed
120/240 Voltage, 2 Poles, 60Hz,
External digital
display and LEDs, NEMA 3R,
UL1008 Listed
No
No
No
No
MGVATS6001480
MGVATS10001240
MGVATS10001208
MGVATS10001480
Three Phase 480V
(add’l voltages available)
Single Phase 240V
(add’l voltages available)
Three Phase 208V
(add’l voltages available)
Three Phase 480V
(add’l voltages available)
5 Years
5 Years
5 Years
5 years
Service entrance
disconnect
Dimensions (L x W x H)
Weight
Common features
Power management
MODEL NUMBER
Phase
Limited Warranty
Circuits
N/A
N/A
N/A
N/A
Amps
600A
1000A
1000A
1000A
No
No
No
No
60” x 30” x 25”
60” x 30” x 25”
60” x 30” x 25”
60” x 30” x 25”
425 lbs.
425 lbs.
510 lbs.
542 lbs.
277/480 Voltage, 2 Poles,
60Hz, External digital
display and LEDs, NEMA
3R, UL1008 Listed
120/240 Voltage, 2 Poles,
60Hz, External digital
display and LEDs, NEMA
3R, UL1008 Listed
120/208 Voltage, 2 Poles,
60Hz, External digital
display and LEDs, NEMA
3R, UL1008 Listed
277/480 Voltage, 2 Poles, 60Hz,
External digital
display and LEDs, NEMA 3R,
UL1008 Listed
No
No
No
No
Service entrance
disconnect
Dimensions (L x W x H)
Weight
Common features
Power management
Manual Transfer Switches
30 Amp
MODEL SIZES
Breaker
Amperage
GEN
UTIL
GEN
UTIL
30
60
50
100
Limited Warranty
4 Years
Circuits
Amperage
Enclosure Type
50 Amp
6 circuits included, 8 maximum
30
50
NEMA 3R
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
49
Technical Specifications
MGVATS4001208
MGVATS4001480
MGVATS6001240
MGVATS6001208
Three Phase 208V
(add’l voltages available)
Three Phase 480V
(add’l voltages available)
Single Phase 240V
(add’l voltages available)
Three Phase 208V
(add’l voltages available)
5 Years
5 Years
5 years
5 Years
N/A
N/A
N/A
N/A
400A
400A
600A
600A
No
No
No
No
48” x 30” x 13”
48” x 30” x 13”
60” x 30” x 25”
60” x 30” x 25”
190 lbs.
190 lbs.
425 lbs.
425 lbs.
120/208 Voltage, 2 Poles,
60Hz, External digital
display and LEDs, NEMA
3R, UL1008 Listed
277/480 Voltage, 2 Poles,
60Hz, External digital
display and LEDs, NEMA
3R, UL1008 Listed
120/240 Voltage, 2 Poles,
60Hz, External digital
display and LEDs, NEMA
3R, UL1008 Listed
120/208 Voltage, 2 Poles,
60Hz, External digital
display and LEDs, NEMA
3R, UL1008 Listed
No
No
No
No
MGVATS12501240
MGVATS12501208
MGVATS12501480
Single Phase 240V
(add’l voltages available)
Three Phase 208V
(add’l voltages available)
Three Phase 480V
(add’l voltages available)
5 years
5 years
5 years
N/A
N/A
N/A
1250A
1250A
1250A
No
No
No
60” x 30” x 25”
60” x 30” x 25”
60” x 30” x 25”
542 lbs.
542 lbs.
542 lbs.
120/240 Voltage, 2 Poles,
60Hz, External digital
display and LEDs, NEMA
3R, UL1008 Listed
120/208 Voltage, 2 Poles,
60Hz, External digital
display and LEDs, NEMA
3R, UL1008 Listed
277/480 Voltage, 2 Poles,
60Hz, External digital
display and LEDs, NEMA
3R, UL1008 Listed
No
No
No
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
†Add 1” to depth if N3 enclosure is selected
Vigilant® Series switches are compatible with most Milbank standby
generators, please consult your sales agent for compatibility.
100A and 200A approved UL1008 — Optional Standby System
400A through 1250A approved UL1008 — Emergency Systems
50
Technical Specifications
Portable Generators
MODEL NUMBER
MPG32501
MPG55003
MPG6000S
Manual
Manual
Manual
Rated Watts
3200 Watts
5500 Watts
6000 Watts
Surge Watts
3750 Watts
6750 Watts
7500 Watts
14 Hours
13 Hours
12 Hours
OHV, 4-Stroke
OHV, 4-Stroke
OHV, 4-Stroke
Engine Displacement
208cc
357cc
357cc
Warranty
3 years
3 years
3 years
Yes
Yes
Yes
Fuel Tank Capacity
4.0 Gallons
6.6 Gallons
6.6 Gallons
Low Oil Shutdown
Yes
Yes
Yes
Manual
Yes
Yes
Brush
Brush
Brush
23.7 x 16.9 x 16.7
27.2 x 20.5 x 22
27.2 x 20.5 x 22
100 lbs
172 lbs
183 lbs
31.5 x 21.4 x 23.2
31.5 x 21.4 x 23.2
31.5 x 21.4 x 23.2
108 lbs
184 lbs
195 lbs
4
2
2
2
2
2
0
1
1
25 Amps
21 Amps
23 Amps
NEMA L5-30R (Twist Lock)
0
0
0
NEMA 50A (Twist Lock)
0
0
0
Yes
Yes
Yes
Starting
Run Time @ 1⁄2 Load
Engine
EPA Compliant
Automatic Fuel Shut-Off
Excitation
Unit Dimensions
L x W x H (inches)
Unit Weight
Carton Dimensions
L x W x H (inches)
Shipping Weight
Outlets (Quantity)
NEMA 5-20R (125VAC 20A Duplex)
20 Amp push button circuit breakers
NEMA L14-30R (125/250VAC 30A
Twist Lock)
2 Pole Toggle-Type Main Line Breaker
Oil Bottle (One bottle sized for engine:
SAE10W30)
12V DC Outlet
No
No
No
Oil Funnel
Yes
Yes
Yes
Multi-Outlet
25’ Power Cord*
No
No
Yes
Battery
No
No
No
Wheel Kit
Yes
Yes
Yes
Tool Kit
Yes
Yes
Yes
Fuel Gauge
Yes
Yes
Yes
Hour Meter
No
No
No
Yes (sold separately)
Yes (sold separately)
Yes
Power Cord (25’; 30 AMPs; rated up to 300
Volts)
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
51
Technical Specifications
MPG6500E
MPG70002E
MPG75002E
MPG100001E
Electric
Electric
Electric
Electric
6500 Watts
7000 Watts
7500 Watts
10,000 Watts
8000 Watts
8500 Watts
9000 Watts
12,500 Watts
12 Hours
11 Hours
11 Hours
11 Hours
OHV, 4-Stroke
OHV, 4-Stroke
OHV, 4-Stroke
OHV, 4-Stroke
420cc
420cc
420cc
680cc V-Twin
3 years
3 years
3 years
3 years
Yes
Yes
Yes
Yes
6.6 Gallons
6.6 Gallons
6.6 Gallons
9.2 Gallons
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Brush
Brush
Brush
Brush
27.2 x 20.5 x 22
27.2 x 20.5 x 22
27.2 x 20.5 x 22
30.7 x 31.1 x 31.3
193 lbs
194 lbs
199 lbs
300 lbs
31.5 x 21.4 x 23.2
31.5 x 21.4 x 23.2
31.5 x 21.4 x 23.2
34.6 x 27.5 x 33.2
205 lbs
206 lbs
211 lbs
310 lbs
2
2
2
2
2
2
2
2
1
1
1
1
25 Amps
27 Amps
30 Amps
42 Amps
0
0
0
1
0
0
0
1
Yes
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
Yes
Yes
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes (sold separately)
Yes (sold separately)
Yes (sold separately)
Yes (sold separately)
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 816.410.7346 | milbankworks.com
For more information contact:
Gen/TS Catalog v1.1 | 10.01.15
Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement