AI232 Installation Guide


Add to my manuals
12 Pages

advertisement

AI232 Installation Guide | Manualzz

AI232

32-port High Speed Asynchronous Line Card

Installation Guide

Part Number QR-232 Rev 3

© 2008 by Kentrox, Inc. All rights reserved.

Copyright © 2008 by Kentrox, Inc. All Rights Reserved. The material discussed in this publication is the proprietary property of Kentrox, Inc. Kentrox retains all rights to reproduction and distribution of this publication.

Kentrox is a registered trademark of Kentrox, Inc. Applied Innovation, Applied Innovation Inc., the

AI logo, and other names are the intellectual property of Kentrox. All other product names are trademarks or registered trademarks of their respective owners.

Information published here is current as of this document’s date of publication, but is subject to change without notice. You may verify product information by contacting our headquarters in

Oregon. Kentrox is an Equal Opportunity/Affirmative Action employer.

Kentrox, Inc.

5800 Innovation Dr.

Dublin, Ohio USA 43016-3271

Toll Free: (800) 247-9482

International: +1 (614) 798-2000

Fax: +1 (614) 798-1770

20010 NW Tanasbourne Dr.

Hillsboro, Oregon USA 97124-7104

Toll Free: (800) 733-5511

Direct: (503) 643-1681

AI232

32-port High Speed Asynchronous Line

Card

Installation Guide

This installation guide explains how to install an AI232 32-port high speed asynchronous line card.

Guide to this document

Cautions and Warnings

Customer Assistance

Introduction

Model DP232-19/23 Distribution Panel

Model DP232-RJ45 Distribution Panel

1

Cautions and Warnings

Cautions and Warnings

Grounding and Electrical Safety

CAUTION: AI equipment and its peripherals contain electrostatic sensitive components. Proper handling, shipping, and storage precautions must be exercised: z z z z z

You must remove and install cards in a static-free environment. Wear an antistatic wrist strap that is plugged into the AI equipment so you are grounded at the same point as the equipment.

Do not remove cards from their antistatic plastic bags until you are ready to install them into the chassis.

Immediately after you remove a card from the chassis, you must insert it into its antistatic bag.

When the cards are not in use, keep them in their antistatic plastic bags.

Do not ship or store cards near strong electrostatic, electromagnetic, or radioactive fields.

Installation

CAUTION: For AI equipment to operate safely and correctly, there must be a safety ground strap between the equipment ground bolts and the office ground.

Environment

CAUTION: In the event that AI232 has been subjected to adverse environmental conditions, a service inspection of AI232 should be made to ensure safe operation.

FCC

The Federal Communications Commission has set limits for emitted radio interference, and AI232 is constructed with this electromagnetic interference (EMI) limitation in mind. AI232 is classified under FCC regulations as a Class A device, that is, a device for use in commercial environments and not in residential areas. This device has been tested and shown to comply with the following FCC rule: Part 15

Subpart J. Operation of this equipment in a residential area may cause interference to radio and TV reception, requiring the user to take whatever steps are necessary to correct the interference.

2

Customer Assistance

Information is available from the FCC describing possible corrective actions. To maintain low EMI levels, we suggest that you use only metal connectors and shielded cable grounded to the frame.

Specifications are subject to change without notice.

Customer Assistance

Kentrox offers technical support 24 hours a day, seven days a week.

z z z z

Before you contact Kentrox for assistance, please have the following information available:

The type of hardware and software you are using

The error number and exact wording of any messages that appeared on your screen

What happened and what you were doing when the problem occurred

How you tried to solve the problem

Web Site Support

Support is available 24 hours a day using our Web site at: http://www.kentrox.com

Email Support

Email support is available 24 hours a day. When you use email support, please be sure to include the details of your problem within the email.

To contact Technical Support, send email to: [email protected]

Phone Support

Phone support is available. When you call Kentrox for support, please be sure you are at your computer and have the details of your problem available.

To contact Technical Support, call (866) 480-3571.

Kentrox Product Documentation

To order documentation, please contact your sales representative at

(800) 247-9482 or +1 (614) 798-2000.

You can also access and view the most current versions of Kentrox product documentation on our Web site at: http://www.kentrox.com

3

Introduction

Introduction

Distribution panels provide the physical interface for the AI232 network interface card.

The distribution panels are available in two models providing these interfaces: z z

Model DP232-19/23: 16 DB-25/EIA-232-E interfaces

Model DP232-RJ45: 32 RJ-45/EIA-232-E signals

Model DP232-19/23 Distribution Panel

This distribution panel provides 16 DB-25/EIA-232-E interfaces for the AI232. Two distribution panels are required to access all 32 ports on the AI232. The distribution

panel is available in two sizes for 19-inch or 23-inch rack installations. Figure 1

shows

the distribution panel and Table 1

lists the specifications.

Figure 1: DP232-19/23 Distribution Panel

Connect to Network Elements

(16 ports)

Connect to the AI232

PORT 1/17

PORT 2/18

PORT 3/19

PORT 4/20

PORTS

1 - 8

PORT 5/21

PORT 6/22

PORT 7/23

PORT 8/24

DP232

APPLIED INNOVATION INC.

COPYRIGHT 1999

PORT 9/25

PORT 10/26

PORT 11/27

PORT 12/28

PORTS

9 - 16

PORT 13/29

PORT 14/30

PORT 15/31

PORT 16/32

Table 1: Specifications for DP232-19/23

Description

Mounting

I/O Ports

Weight (approximately)

Size

Specification

DP232-19: mounts to a 19-inch rack

DP232-23: mounts to a 23-inch rack

16 DB-25/EIA-232-E interfaces

2.5 lb (1.12 kg)

Height: 4 in. (10.16 cm)

Width: 19 in. (48.26 cm)/23 in. (58.42 cm)

Depth: 1.12 in. (2.84 cm)

4

Model DP232-19/23 Distribution Panel

Table 1: Specifications for DP232-19/23 (Continued)

Description

Pin Assignments

Specification

Pin 1

Pin 13

Pin 14

Pin 25

Pin

2

3

4

5

6

7

8

20

Signal

TXD

RXD

RTS

CTS

DSR

Signal GND

DCD

DTR

Cables z z

CAB467: Connects one connector (8 ports) on the AI232 to the distribution panel. Each distribution panel requires two cables.

CAB469: Connects network elements to the individual connectors on the distribution panel.

5

6

Model DP232-19/23 Distribution Panel

Installation Procedure

1. Install the distribution panel(s) to the rack.

Figure 2

shows a typical installation.

2. Attach cables from the AI232 to the distribution panel.

Figure 2: Typical Installation

Cable: CAB467

(4 places)

PORT 1

PORT 2

PORT 3

PORT 4

PORT 1

PORT 2

PORT 3

PORT 4

DP232-19/23

PORT 5

PORT 6

PORT 7

PORT 8

PORT 9

PORT 10

PORT 11

PORT 12

PORT 13

PORT 14

PORT 15

PORT 16

PORT 5

PORT 6

PORT 7

PORT 8

PORT 9

PORT 10

PORT 11

PORT 12

PORT 13

PORT 14

PORT 15

PORT 16

AI232

(AI180 Chassis)

-

Model DP232-RJ45 Distribution Panel

Model DP232-RJ45 Distribution Panel

This model provides 32 RJ-45/EIA-232-E signals for the AI232. Reversible mounting flanges allow installation to a 19-inch or 23-inch rack.

Figure 3

shows the distribution panel and

Table 2 lists the specifications.

Figure 3: DP232-RJ45 Distribution Panel

Connect to Network Elements

(32 ports)

Connect to the AI232

(4 places)

1

17

WWW.AIINET.COM

4

PORTS 1 - 8

5

20

PORTS 17 - 24

21

8 9

DP232-RJ45

24 25

12

PORTS 9 - 16

13

28

PORTS 25 - 32

29

16

32

Table 2: Specifications for DP232-RJ45

Description

Mounting

I/O Ports

Weight (approximately)

Size

Pin Assignments

Specification

Reversible mounting flanges allow installation to a 19inch or 23-inch rack.

32 RJ-45 ports

4.8 lb (2.16 kg)

Height: 2 in. (5.08 cm)

Width: 16.9 in. (42.92 cm) without mounting flanges

Depth: 3.5 in. (8.89 cm)

Pin 1 Pin 8

6

7

4

5

8

Pin Signal

1 RTS

2

3

DTR

TXD

DCD

RXD

GND

DSR

CTS

7

Model DP232-RJ45 Distribution Panel

Table 2: Specifications for DP232-RJ45 (Continued)

Description

Cables

Specification

z z

CAB467: Connects one connector (8 ports) on the

AI232 to the distribution panel. The distribution panel requires four cables.

CAB182: Connects network elements to the individual connectors on the distribution panel

(straight through applications).

Installation Procedure

1. Attach the mounting flanges and tie bar as shown in

Figure 4

. (

Table 3

shows the part list.)

Figure 4: DP232-RJ45 Distribution Panel

12

PORTS 9 - 16

13 16 1 4

PORTS 1 - 8

5

WWW.AIINET.COM

17 20

PORTS 17 - 24

21

Setting flanges for a 19-inch rack

Install the mounting flanges in the desired location

8 9

DP232-RJ45

24 25 28

PORTS 25 - 32

29 32

Setting flanges for a 23-inch rack

Install the mounting flanges in the desired location

8

4

1

5

3

1

5

3

Table 3: Parts List

Item Description

1 Tie Bar

2 Mounting Flange (left side)

Part No.

06-410-

002

06-110-

003

Quantity

1

1

4

Model DP232-RJ45 Distribution Panel

Table 3: Parts List

Item Description

3 Mounting Flange (right side)

4

5

#6-32 Screw with lockwasher

#12-24 Screw with lockwasher

Part No.

06-110-

005

00-018-

001

00-015-

003

Quantity

1

6

2

2. Install the distribution panel to the rack. Figure 5 shows a typical installation.

Figure 5: Typical Installation

Cable: CAB467

(4 places)

DP232-RJ45

1

17

4

PORTS 1 - 8

5

WWW.AIINET.COM

20

PORTS 17 - 24

21

8 9

DP232-RJ45

24 25

12

PORTS 9 - 16

13

28

PORTS 25 - 32

29

16

32

AI232

AI180 Chassis

-

9

10

Model DP232-RJ45 Distribution Panel

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement