AI232
32-port High Speed Asynchronous Line Card
Installation Guide
Part Number QR-232 Rev 3
© 2008 by Kentrox, Inc. All rights reserved.
Copyright © 2008 by Kentrox, Inc. All Rights Reserved. The material discussed in this publication is the proprietary property of Kentrox, Inc. Kentrox retains all rights to reproduction and distribution of this publication.
Kentrox is a registered trademark of Kentrox, Inc. Applied Innovation, Applied Innovation Inc., the
AI logo, and other names are the intellectual property of Kentrox. All other product names are trademarks or registered trademarks of their respective owners.
Information published here is current as of this document’s date of publication, but is subject to change without notice. You may verify product information by contacting our headquarters in
Oregon. Kentrox is an Equal Opportunity/Affirmative Action employer.
Kentrox, Inc.
5800 Innovation Dr.
Dublin, Ohio USA 43016-3271
Toll Free: (800) 247-9482
International: +1 (614) 798-2000
Fax: +1 (614) 798-1770
20010 NW Tanasbourne Dr.
Hillsboro, Oregon USA 97124-7104
Toll Free: (800) 733-5511
Direct: (503) 643-1681
AI232
32-port High Speed Asynchronous Line
Card
Installation Guide
This installation guide explains how to install an AI232 32-port high speed asynchronous line card.
Guide to this document
Model DP232-19/23 Distribution Panel
Model DP232-RJ45 Distribution Panel
1
Cautions and Warnings
Cautions and Warnings
Grounding and Electrical Safety
CAUTION: AI equipment and its peripherals contain electrostatic sensitive components. Proper handling, shipping, and storage precautions must be exercised: z z z z z
You must remove and install cards in a static-free environment. Wear an antistatic wrist strap that is plugged into the AI equipment so you are grounded at the same point as the equipment.
Do not remove cards from their antistatic plastic bags until you are ready to install them into the chassis.
Immediately after you remove a card from the chassis, you must insert it into its antistatic bag.
When the cards are not in use, keep them in their antistatic plastic bags.
Do not ship or store cards near strong electrostatic, electromagnetic, or radioactive fields.
Installation
CAUTION: For AI equipment to operate safely and correctly, there must be a safety ground strap between the equipment ground bolts and the office ground.
Environment
CAUTION: In the event that AI232 has been subjected to adverse environmental conditions, a service inspection of AI232 should be made to ensure safe operation.
FCC
The Federal Communications Commission has set limits for emitted radio interference, and AI232 is constructed with this electromagnetic interference (EMI) limitation in mind. AI232 is classified under FCC regulations as a Class A device, that is, a device for use in commercial environments and not in residential areas. This device has been tested and shown to comply with the following FCC rule: Part 15
Subpart J. Operation of this equipment in a residential area may cause interference to radio and TV reception, requiring the user to take whatever steps are necessary to correct the interference.
2
Customer Assistance
Information is available from the FCC describing possible corrective actions. To maintain low EMI levels, we suggest that you use only metal connectors and shielded cable grounded to the frame.
Specifications are subject to change without notice.
Customer Assistance
Kentrox offers technical support 24 hours a day, seven days a week.
z z z z
Before you contact Kentrox for assistance, please have the following information available:
The type of hardware and software you are using
The error number and exact wording of any messages that appeared on your screen
What happened and what you were doing when the problem occurred
How you tried to solve the problem
Web Site Support
Support is available 24 hours a day using our Web site at: http://www.kentrox.com
Email Support
Email support is available 24 hours a day. When you use email support, please be sure to include the details of your problem within the email.
To contact Technical Support, send email to: [email protected]
Phone Support
Phone support is available. When you call Kentrox for support, please be sure you are at your computer and have the details of your problem available.
To contact Technical Support, call (866) 480-3571.
Kentrox Product Documentation
To order documentation, please contact your sales representative at
(800) 247-9482 or +1 (614) 798-2000.
You can also access and view the most current versions of Kentrox product documentation on our Web site at: http://www.kentrox.com
3
Introduction
Introduction
Distribution panels provide the physical interface for the AI232 network interface card.
The distribution panels are available in two models providing these interfaces: z z
Model DP232-19/23: 16 DB-25/EIA-232-E interfaces
Model DP232-RJ45: 32 RJ-45/EIA-232-E signals
Model DP232-19/23 Distribution Panel
This distribution panel provides 16 DB-25/EIA-232-E interfaces for the AI232. Two distribution panels are required to access all 32 ports on the AI232. The distribution
panel is available in two sizes for 19-inch or 23-inch rack installations. Figure 1
shows
the distribution panel and Table 1
lists the specifications.
Figure 1: DP232-19/23 Distribution Panel
Connect to Network Elements
(16 ports)
Connect to the AI232
PORT 1/17
PORT 2/18
PORT 3/19
PORT 4/20
PORTS
1 - 8
PORT 5/21
PORT 6/22
PORT 7/23
PORT 8/24
DP232
APPLIED INNOVATION INC.
COPYRIGHT 1999
PORT 9/25
PORT 10/26
PORT 11/27
PORT 12/28
PORTS
9 - 16
PORT 13/29
PORT 14/30
PORT 15/31
PORT 16/32
Table 1: Specifications for DP232-19/23
Description
Mounting
I/O Ports
Weight (approximately)
Size
Specification
DP232-19: mounts to a 19-inch rack
DP232-23: mounts to a 23-inch rack
16 DB-25/EIA-232-E interfaces
2.5 lb (1.12 kg)
Height: 4 in. (10.16 cm)
Width: 19 in. (48.26 cm)/23 in. (58.42 cm)
Depth: 1.12 in. (2.84 cm)
4
Model DP232-19/23 Distribution Panel
Table 1: Specifications for DP232-19/23 (Continued)
Description
Pin Assignments
Specification
Pin 1
Pin 13
Pin 14
Pin 25
Pin
2
3
4
5
6
7
8
20
Signal
TXD
RXD
RTS
CTS
DSR
Signal GND
DCD
DTR
Cables z z
CAB467: Connects one connector (8 ports) on the AI232 to the distribution panel. Each distribution panel requires two cables.
CAB469: Connects network elements to the individual connectors on the distribution panel.
5
6
Model DP232-19/23 Distribution Panel
Installation Procedure
1. Install the distribution panel(s) to the rack.
shows a typical installation.
2. Attach cables from the AI232 to the distribution panel.
Figure 2: Typical Installation
Cable: CAB467
(4 places)
PORT 1
PORT 2
PORT 3
PORT 4
PORT 1
PORT 2
PORT 3
PORT 4
DP232-19/23
PORT 5
PORT 6
PORT 7
PORT 8
PORT 9
PORT 10
PORT 11
PORT 12
PORT 13
PORT 14
PORT 15
PORT 16
PORT 5
PORT 6
PORT 7
PORT 8
PORT 9
PORT 10
PORT 11
PORT 12
PORT 13
PORT 14
PORT 15
PORT 16
AI232
(AI180 Chassis)
-
Model DP232-RJ45 Distribution Panel
Model DP232-RJ45 Distribution Panel
This model provides 32 RJ-45/EIA-232-E signals for the AI232. Reversible mounting flanges allow installation to a 19-inch or 23-inch rack.
shows the distribution panel and
Table 2 lists the specifications.
Figure 3: DP232-RJ45 Distribution Panel
Connect to Network Elements
(32 ports)
Connect to the AI232
(4 places)
1
17
WWW.AIINET.COM
4
PORTS 1 - 8
5
20
PORTS 17 - 24
21
8 9
DP232-RJ45
24 25
12
PORTS 9 - 16
13
28
PORTS 25 - 32
29
16
32
Table 2: Specifications for DP232-RJ45
Description
Mounting
I/O Ports
Weight (approximately)
Size
Pin Assignments
Specification
Reversible mounting flanges allow installation to a 19inch or 23-inch rack.
32 RJ-45 ports
4.8 lb (2.16 kg)
Height: 2 in. (5.08 cm)
Width: 16.9 in. (42.92 cm) without mounting flanges
Depth: 3.5 in. (8.89 cm)
Pin 1 Pin 8
6
7
4
5
8
Pin Signal
1 RTS
2
3
DTR
TXD
DCD
RXD
GND
DSR
CTS
7
Model DP232-RJ45 Distribution Panel
Table 2: Specifications for DP232-RJ45 (Continued)
Description
Cables
Specification
z z
CAB467: Connects one connector (8 ports) on the
AI232 to the distribution panel. The distribution panel requires four cables.
CAB182: Connects network elements to the individual connectors on the distribution panel
(straight through applications).
Installation Procedure
1. Attach the mounting flanges and tie bar as shown in
. (
shows the part list.)
Figure 4: DP232-RJ45 Distribution Panel
12
PORTS 9 - 16
13 16 1 4
PORTS 1 - 8
5
WWW.AIINET.COM
17 20
PORTS 17 - 24
21
Setting flanges for a 19-inch rack
Install the mounting flanges in the desired location
8 9
DP232-RJ45
24 25 28
PORTS 25 - 32
29 32
Setting flanges for a 23-inch rack
Install the mounting flanges in the desired location
8
4
1
5
3
1
5
3
Table 3: Parts List
Item Description
1 Tie Bar
2 Mounting Flange (left side)
Part No.
06-410-
002
06-110-
003
Quantity
1
1
4
Model DP232-RJ45 Distribution Panel
Table 3: Parts List
Item Description
3 Mounting Flange (right side)
4
5
#6-32 Screw with lockwasher
#12-24 Screw with lockwasher
Part No.
06-110-
005
00-018-
001
00-015-
003
Quantity
1
6
2
2. Install the distribution panel to the rack. Figure 5 shows a typical installation.
Figure 5: Typical Installation
Cable: CAB467
(4 places)
DP232-RJ45
1
17
4
PORTS 1 - 8
5
WWW.AIINET.COM
20
PORTS 17 - 24
21
8 9
DP232-RJ45
24 25
12
PORTS 9 - 16
13
28
PORTS 25 - 32
29
16
32
AI232
AI180 Chassis
-
9
10
Model DP232-RJ45 Distribution Panel
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement