Kemlan C24 MK II wood heater Installation, operating and maintenance manual

Kemlan C24 MK II wood heater Installation, operating and maintenance manual

The Kemlan C24 MK II is a freestanding wood heater designed for heating your home. It features a 6mm firebox for durability and a powerful fan for efficient heat distribution throughout your space.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Kemlan C24 MK II Manual | Manualzz
 | E
design 8 manufacture
| | | Kemlan Industries Pty Ltd |
o = Е | Head Office: 59 Pineapple Street (PO Box 259) Zillmere Queensland 4034
ESTABLISHED 1969 Telephone: (07) 3263 8488 Facsimile: (07) 3263 6452 www.kemlan.com
ABN 43 003 209 961 Business hours: Monday to Thursday 7.30am-4.00pm * Friday 7.30am-2.00pm
Email: [email protected]
KEMLAN C24 MK II
FREESTANDING WOOD HEATING APPLIANCE
INSTALLATION, OPERATING AND MAINTENANCE
MANUAL
SAVE THESE INSTRUCTIONS
PARTICULATE EMISSIONS POWER OUTPUT AND EFFICIENCY TESTING OF
THE KEMLAN C24
FREE STANDING SOLID FUEL APPLIANCE
Report
The Kemlan C24 solid fuel appliance was tested for particulate emissions power output and
efficiency according to the requirements of the joint Australian/New Zealand Standard AS/NZS
4012/4013 (1999).
The appliance particulate emissions factor was 1.4g/kg of hardwood, and the combined
efficiency of the appliance for all burn rates was 68%. a
The Kemlan C24 solid fuel appliance complies with the requirements of AS/NZS 4012/4013
(1999). |
Investigation: S. Marland
Report: S. Marland
Checked by: J. Kaiser
Signed: (4%. Li.... Lodo Tien, Approved... LZ TT ee Srervuses
S. Marland B Ham
Technical Officer Manager Gippsland
HRL Technology Pty Ltd HCMG/06/009.
Page 3 of 9
THERMAL CLEARANCE TESTING OF THE
KEMLAN C24 SOLID FUEL
APPLIANCE TESTED WITH A KEMLAN DOUBLE FLUE KIT
Report
The appliance and flue system were installed into a standard Clearance Test enclosure and tested in
two positions in a manner conforming to joint Australian/New Zealand Standard 2918:2001,
Appendix B. A minimum 810mm deep x 850mm wide x 6.0mm thick floor protector (cement fibre
sheet) should be used under and in front of the appliance base when installing the appliance (see
joint AS/NZS 2918:2001 3.3.2). The floor protector should extend 350mm in front of the
appliance base. The Thermal conductivity of the floor protector 1s 0.8 m”.K/W for 4mm sheets.
A 900mm x 130 degree stainless rear flue shield must also be installed directly behind the active
— fue.
The Kemlan C24 solid fuel appliance, when installed with a Kemlan Double flue system; conforms
to the requirements of joint AS/NZS 2918:2001, Appendix B, with respect to rear wall, side wall,
floor and ceiling surface temperatures, when tested in the positions described in this report and
using Pinus radiata firewood as the fuel type.
TEST POSITIONS
The appliance and flue combinations were tested at the following clearances:
Position A (Parallel)
150mm from rear wall to the edge of the appliance rear panel.
450mm from side wall to the edge of the appliance side panel.
Position B (Corner)
225mm from walls when measured from the rear corners of the appliance (43° to both
walls).
Refer to Appendix 1 of this report for clearance diagrams.
Investigation: J. Kaiser & S. Marland
Report: SMardad
Checked by: J. Kaiser
Signed: A ALAA ae Lecsscrners Approved: .......=— ZT, Доне НН
S. Marland B. Ham
Technical Officer Manager, Gippsland
HCMG/06/011
HRL Technology Pty Ltd | | Page 3 of 9
р S / NZS 4013: 1995
TA i 5 | as /NZS4014:199
E о 3 o | 2 E as / №58 4012:1999 с о a
ZA _ CERTIFIC ATE No: Æ 485-0706 _ DATE. -— e “| | i
= = = = о = = == = = = = = = = - mses em mm, - ое =“
" 5 | - Brisbane, , Queensland | ess E SE
AZ in fire pl ace design & manufacture
ee | WB Kemian Industries Pty Ltd
E | Head Office: 59 Pineapple Street (PO Box 259) Zillmere Queensland 4034
ESTABLISHED 1969 Telephone: (07) 3263 8488 Facsimile: (07) 3263 6452 www.kemlan.com
ABN 43 003 209 961 Business hours: Monday to Thursday 7.30am-4.00pm * Friday 7.30am-2.00pm
Email: [email protected]
INSTALLATION INSTRUCTIONS
WARNING: THE APPLIANCE AND FLUE SYSTEM SHALL BNE INSTALLED IN
ACCORDANCE WITH AS 2918 AND THE APPROPRIATE REQUIREMENTS OF THE
LOCAL BUILDING REGULATORY AUTHORITY
KEMLAN STRONGLY RECOMMENDS YOU ENGAGE A QUALIFIED INSTALLER TO
CARRY OUT THE INSTALLATION.
NOTIFY YOUR INSURANCE COMPANY OF YOUR INTENTION TO INSTALL A WOOD
HEATING APPLIANCE IN YOUR HOME.
CAUTION: MIXING OF THE APPLIANCE OF FLUE SYSTEM COMPONENTS FROM
DIFFERENT SOURCES OR MODIFYING THE DIMENSIONAL SPECIFICATION OF CO
~ PONENTS MAY RESULT IN HAZARDOUS CONDITIONS. WHERE SUCH ACTION IS
CONSIDERED, THE MANUFACTURER SHOULD BE CONSULTED IN THE FIRST
INSTANCE.
CAUTION: CRACKED AND BROKEN COMPONENTS eg. GLASS PANELS OR FIRE
BRICKS MAY RENDER THE INSTALLATION UNSAFE.
THIS APPLIANCE SHOULD NOT BE MODIFIED IN ANY WAY WITHOUT THE WRITTEN
APPROVAL; OF THE MANUFACTURER AND IT IS RECOMMENDED THE FLUE SUSTEM
AND UNIT BE INSTALLED BY A QUALIFIED INSTALLER.
THE PARTS AND MATERIALS REQUIRED FOR THE INSTALLATION OF THE
APPLIANCE ARE -
1. A suitable floor protector is required if the appliance is being installed on a heat
sensitive floor. Floor protector specifications — |
Thickness to be a minimum of 6mm thick fibre cement sheet (CSR 6mm ceramic tile
underlay or equivalent). A heat resistant material (tiles, slate, granite, marble or metal)
shall be placed on top of the fibre cement sheet to finish.
Note: Material with a thermal conductivity of equal or less than 0.41 W/m degree K
may be substituted for 6mm fibre cement sheet.
Minimum size requirements-
Standard Installation: 975 mm x 1000 mm
Corner Installation: 1325 mm x 1325 mm with a 500 mm front edge
The floor protector must extend a minimum of 200 mm on either side of firebox
opening and 350 mm in front of firebox opening.
2 Your Kemlan wood heating appliance. (Refer to page 3 for clearances to heat
sensitive material). |
3 A Kemlan flue system (refer to pages 4 & 5) or a flue system which complies with
AS2918.
design & manufacture
E Kemlan Industries Pty Ltd
E | Head Office: 59 Pineapple Street (POBox 259) Zillmere Queensland 4034
| Telephone: (07) 3263 8488 Facsimile: (07) 3263 6452 www.kemlan.com
ESTABLISHED 1969
| ABN 43 003 209 961 Business hours: Monday to Thursday 7.30am-4.00pm * Friday 7.30am-2.00pm
Email: [email protected]
4 A heat shield 900 mm long must be placed over or fitted to the first length of flue for
protection of heat sensitive material on or behind the wall
‚ 5 A suitable roof flashing — refer to your local Kemlan retail out let for details
6 Flue Height — Except where a flue pipe term9inates within a chimney, the flue exit
shall be located outside the building in which the appliance is installed so that —
a) Itis level not less than 100 mm above the level at which the axis of the flue
pipe penetrates or passes the roof of the building;
b) No part of the building lies in or above a circular area described by a
horizontal radius of 3 m about the flue exit
c) Termination of the flue does not constitute a risk of fire to nearby heat
sensitive materials, and
d) There is no risk of penetration of flue though nearby windows or other
openings, fresh air inlets, mechanical ventilation inlets or exhausts, or the
like.
In areas with strong winds and high structures and trees, drafts may occur and in
which case we recommend a storm collar be fitted to the double cone cowl.
7 tis necessary to ensure that the weight of the flue pipe is adequately supported.
Stainless Steel Flue pipes can expand 7mm per metre length between ambient and
operating temperature.
All joints between sections of flue pipes shall be either —
I) Continuously welded or
i) Push fitted and secured to prevent separation
8 All furniture, clothes, drapes, firewood and other moveable combustible items must
be kept a minimum of 1200 mm from the appliance.
9 The appliance conforms to the safety standards As2918 and AS 3869.
When in use some parts may become hot. A suitable fireguard is recommended
where the very young, elderly or infirm are concerned.
APPENDIX 1:
MINIMUM CLEARANCES FOR THE KEMLAN C24
SOLID FUEL APPLIANCE INSTALLED WITH
A KEMLAN DOUBLE FLUE KIT
150mm
A
450mm
810mm
200mm 350mm
| У
4 850mm >
Position A
The floor protector
consisted of 6.0mm thick
cement fibre sheet which
had a thermal resistance
of 0.8 m”.K/W for 4mm
sheets.
810mm
350mm
Â
Y
850mm
Position B
. HCMG/06/011
HRL Technology Pty Ltd | | Appendix |
ati st s
m a n u f a ct ur
Kemlan Industries Pty Ltd
‚8? Head Office: 59 Pineapple Street (PO Box 259) Zillmere Queensland 4034
| о, 69 Telephone: (07) 3263 8488 Facsimile: (07) 3263 6452 www.kemlan.com
ABN 43 003 209 961 Business hours: Monday to Thursday 7.30am-4.00pm * Friday 7.30am-2.00pm
TRIM LINE
OUTER CASING MAY BE PAINTED
WITHOUT PRIMING. RUN A BEAD OF SILICON
DOWN SEAM OF QUIER CASING TO ENSURE AGAINST LFAKS
AL CASING FLUE PIPES MUST BE CONNECTED
WITH POP RIVETS SUPPLIED BY INSTALLER
SIANLESS SIEEL DOUBLE
CONE COM
7
BRACING SUPPLIED BY INSTALLER
SHORT TUBE FITS INTO FLUE PIPE
ALL FLUES SHOULD BE TRIMMED LEVEL
1000mm MIN DISTANCE
ABOVE ROOF LINE
A
> ROOF FLASHING
10 THE QUISE OF THE OUTER CASING AT SUPPLIED BY INSTALLER
= STAINLESS STEEL FLUE PIPE
ALL FLUE PRES MUST BE CONNECTED
WII POP RNETS SUPPLIED BY INSTALLER
Ра
SUPPORT OUTER FLUE WITH
ERACKETS SUPPLIED \
— LL. я
Р \
0 MIN AR CAP 10 MN AR GP Lu NC UNO
=
Ë
POP RIVET OR SCREW BRACKETS A
| NOTE -- When Decromesh/Heatshield is fitted,
a it must finish a minimum of 600mm below the
ceiling or extend through the ceiling drop box
into the outer flue casing.
СК
PLAIE — VENTED CAP
Kain
с
| HEATER OR STOVE |
$ ALWAYS COVER STOVE COMPLETELY UNTIL INSTALLATION AND CLEAN-UP IS COMPLETE *
DOUBLE FLUE KIT — FLAT CEILING — INSTALLATION INSTRUCTIONS
0 COMPLY TO ASINZS 2918
& mm a n uf a ¢ tur e
Kemlan Industries Pty Ltd
Head Office: 59 Pineapple Street (PO Box 259) Zillmere Queenstand 4034
Telephone: (07) 3263 8488 Facsimile: (07) 3263 6452 www.kemlan.com
ABN 43 003 209 961 Business hours: Monday to Thursday 7.30am-4.00pm * Friday 7.30am-2.00pm
[RIM LINE
STANLESS STEEL DOUBLE
CONE COWL
| QUIER CASING MAY BE PANIED
yd | ‚WITHOUT PRIMING. RUN A BEAD OF SILICON
on / DE DOWN SEAM OF OUTER CASING TO ENSURE AGANST LEAKS
ALL CASING FLUE PIPES MUST BE CONNECTED
N WH. POP RMETS SUPPLIEO BY INSTALLER
————;—— Ú —— H— а > “
- SHORT TUBE FIS INTO FLUE PPE >
ALL FLUES SHOULD BE TRIMMED LEVEL =
=
POP RMT OR SCREW BRACKETS 8
10 THE OUTSIDE OF THE OUTER CASNG = | L
= Рони BRACING SUPPLED BY INSTALLER
+><l
[er
ROCF FLASHNC CEILING LINE
SUPPLIED BY INSTALLER
| ma
40 MIN AR
40 MN AR GAP 0 MIN AR ОР STAMLESS STEEL FLUE PPE
ALL FLUE PIPES MUST BE CONNECTED
o] WITH POP RVEIS SUPPLIED BY INSTALLER
LL
pu CENING PLATE
и 7
7 | NOTE — When Decromesh/Heatshield is fitted,
= | it must finish a minimum of 600mm below the
| > Ge ceiling or extend through the ceiling drop box
2 ; into the outer flue casing.
%
%
€ |
VENTED CAP
HEN
Г
| HEATER OR STOVE |
$ ALWAYS COVER STOVE COMPLETELY UNTIL INSTALLATION AND CLEAN-UP IS COMPLETE +
DOUBLE FLUE KIT — RAKED CEILING — INSTALLATION INSTRUCTIONS
INSTALLATION TO COMPLY TO AS/NZS 2918
specialists in fireplace design & manufacture
ня Head Office: 59 Pineapple Street (PO Box 259) Zillmere Queensland 4034
E = И | | Telephone: (07) 3263 8488 Facsimile: (07) 3263 6452 www.kemlan.com
ESTABLISHED !969 | Business hours: Monday to Thursday 7.30am-4.00pm * Friday 7.30am-2.00pm
ABN 43 003 209 961 |
OPERATING INSTRUCTIONS
WARNING: THIS APPLIANCE MUST NOT BE OPERATED AS AN OPEN FIRE.
DO NOT OPERATE WITH DOOR OPEN.
WARNING: DO NOT USE FLAMMABLE LIQUIDS SUCH AS PETROL, KEROSENE, OR
ENGINE OIL TO START OR REKINDLE THE FIRE.
THIS APPLIANCE HAS BEEN TESTED TO AUSTRALIAN STANDARDS USING
HARDWOOD ONLY.
1. Open the air inlet by sliding the air inlet control to high. The air inlet control is located
below the badge on the front face of the appliance.
2. Crumple at least three double pages of newspaper into loose balls and piace them
— directly onto the firebrick lined floor of the firebox. Firestarters may be used as an
alternative to paper.
Cross lay at least 15 to 20 pieces of kindling on top of the paper — if pine is used, the
size should vary from the thickness of a pencil to that of a knife handle — if hardwood
is used split it even smaller. Pine can be used as kindling for starting the fire but
must not be used constantly.
3. Light the paperffirestarters and close the door. N.B. Ventilate the house during the
first three times the stove is used see Safety Precautions on curing the paint.
4. Once the kindling is well alight, add a few pieces of slightly larger hardwood, split to
approximately 25 x 50mm (2" x 1"). Close the door and leave the air inlet control on
high. When the hardwood is well alight (usually 10 to 15 minutes) and embers are
starting to form, larger pieces of hardwood may be added — up to eight pieces the
equivalent of 50 x somm (2° x 2") is ideal.
The object is to create a fiercely burning fire of reasonably small hardwood, which will
quickly produce a good bed of glowing embers on the floor of the firebox. This will
take from 20 to 40 minutes depending on the Quality of the firewood. Use dry
seasoned hardwood.
5. Larger pieces of hardwood may now be added. Rake the embers so they are evenly
spread over the floor of the firebox. Fill the firebox and leave the air inlet control on
high until the wood is well alight, then close the control approximately a third of its
travel. Usually about one hour after lighting, the air inlet control can be further shut
down to achieve the desired heat output
CAUTION: WHEN THE APPLIANCE IS IN OPERATION, OPEN THE AIR INLET
BEFORE OPENING THE DOOR
IMPORTANT: Always load the hardwood from front to back. Never load the
hardwood across the width of the opening. Always allow a small gap between the
hardwood pieces so the flame can move freely. After adding hardwood to the firebox,
open the air inlet for approximately 15 to 25 minutes until the new pieces are buming
well, then it may be returned to its desired setting.
6.
specialists in fireplace design & manufacture
aKemLan
ESTABLISHED 1969 Business hours: Monday to Thursday 7.30am-4.00pm * Friday 7.30am-2.00pm
ABN 43 003 209 961
To set the fire for an extended burn, fill the firebox with hardwood and fully open the
air inlet for approximately 15 to 25 minutes. Once the fire is burning well, shut down
the air inlet control. Setting the air inlet control may be varied to suit your particular
requirements and the quality and size of your firewood.
Remember wet or green wood will cause a dramatic reduction in the heat output of
your heater.
CAUTION: THE USE OF SOME TYPES OF PRESERVATIVE - TREATED WOOD
AS A FUEL CAN BE HAZARDOUS. |
WARNING: DO NOT USE AEROSOLS OR PLACE AEROSOL CANS IN THE
VICINITY OF THIS APPLIANCE WHEN IT IS OPERATING.
WARNING: THIS APPLIANCE MUST NOT BE OPERATED WITH A CRACKED
GLASS. REPLACEMENT GLASS IS AVAILABLE FROM YOUR LOCAL KEMLAN
RETAIL OUTLET. ©
Head Office: 59 Pineapple Street (PO Box 259) Zillmere Queensland 4034
Telephone: (07) 3263 8488 Facsimile: (07) 3263 6452 www.kemlan.com
Specialists in fireplace de si manufacture
LÀ | Head Office: 59 Pineapple Street (PO Box 259) Zillmere Queensland 4034
on E | Telephone: (07) 3263 8488 Facsimile: (07) 3263 6452 www.kemlan.com
ESTABLISHED 1969 Business hours: Monday to Thursday 7.30am-4.00pm * Friday 7.30am-2.
ABN 43 003 209 961 - Y y 7.30am-4.00p y 7-30am-2.00pm
MAINTENANCE INSTRUCTIONS
CAUTION ONLY CLEAN THE APPLIANCE WHEN IT IS AT ROOM TEMPERATURE
1. The flue system must be kept clean and in good condition. Have the flue
inspected at least once every 12 months — preferably before the start of the
winter season. The appliance needs to be cleaned frequently because soot,
creosote and ash may accumulate. In the event of a soot or creosote fire (flue
fire) ensure door is kept closed and shut down the air inlet control.
Following a flue fire the flue system should be inspected by a qualified
installer or other competent person and any damaged components replaced.
2. If the glass door in your heater becomes dirty, your firewood is either green,
wet, or both. You may be closing the air inlet down too soon after lighting or
after adding new firewood.
To clean the glass simply use some of the white ash in the firebox. Apply it
with a damp cloth in a circular motion. Remove residue with a ciean cloth or
paper.
“BROKEN GLASS - REPLACE CRACKED OR BROKEN GLASS
IMMEDIATELY. DO NOT OPERATE UNTIL REPAIRED. USE ONLY
- ROBAX OR PYROCERAM HIGH TEMPERATURE GLASS 5 MM THICK.
3. To clean the painted surface, simply dust with a soft duster and wipe over with
a dry cloth. Under no circumstances should any solvents such as methylated
spirits, petrol, mineral turpentine etc be allowed to come in contact with the
painted surface of the heater as damaged to finish will result. if an accident
does occur spray can paint is available from your local Kemian retail outlet.
Paint The paint work on the appliance can be touched up by using Stove
Bright high temperature paint, which is available through your local Kemian
retail outlet.
4 Clean out excess ash from the floor of he firebox when required. Dispose of
the ash in a steel container with a tightly fitting lid and move outdoors
immediately. Do not use a plastic or an inflammable container.
5. Do not remove all the ash and in particular leave any pieces of charcoal in the
heater, as they are good fuel.
6, All parts and replaceable components are available through your local Kemlan
retail outlet.
7. Fan — A build up of dust may occur. To clean turn off power and remove the
plug — remove fan and vacuum or biow dust. The fan is reached by removing
the three (3) bolts at the lower rear of the unit.
8. At the end of each season — |
(1) The appliance should be cleaned and checked.
(if) Lube door latch and hinges with an anti — seize lubricant.
(iii) Touch up paint surface if necessary.
(iv) Inspection and cleaning of flue system.
specialists
fi re pl ace design & manufactur
м RE Head Office: 59 Pineapple Street (PO Box 259) Zillmere Queensland 4034
© = | Telephone: (07) 3263 8488 Facsimile: (07) 3263 6452 www.kemlan.com
ESTABLISHED 1969 | Business hours: Monday to Thursday 7.30am-4.00pm * Friday 7.30am-2.00pm
ABN 43 003 209 961
SAFETY PRECAUTIONS
Statements Pursuant to AS / NZS 3869 - Clause 7.2.2 & 7.2.3
INSTALLATION
(1)
(if)
(iii)
(iv)
v)
WARNING: THE APPLIANCE AND FLUE SYSTEM SHALL BE INSTALLED IN
ACCORDANCE WITH AS/NZ 2918 AND THE APPROPRIATE REQUIREMENTS OF
THE LOCAL BUILDING REGULATORY AUTHORITY.
CAUTION: MIXING OF APPLIANCE OR FLUE SYSTEM COMPONENTS FROM
DIFFERENT SOURCES OR MODIFYING THE DIMENSIONAL SPECIFICATION OF
COMPONENTS MAY RESULT IN HAZARDOUS CONDITIONS. WHERE SUCH
ACTION IS CONSIDERED, THE MANUFACTURER SHOULD BE CONSULTED IN
THE FIRST INSTANCE.
THE APPLIANCE AND FLUE SYST EM MUST BE INSTALLED STRICTLY IN
ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS.
MINIMUM CLEARANCES AS SET OUT IN THE INSTALLATION INSTRUCTIONS
MUST BE COMPLIED WITH. ENSURE SOLID FUEL, HOUSEHOLD ITEMS AND
FURNITURE ARE AT LEAST 1.2 METRES FROM THE APPLIANCE AT ALL TIMES.
THIS APPLIANCE MUST NOT BE MODIFIED IN ANY WAY WITHOUT
MANUFACTURERS SPECIFIC INSTRUCTIONS. ВЕ
OPERATION
(vi)
(vii)
(viii)
(x)
©
x
(xii)
WARNING: DO NOT USE FLAMMABLE LIQUIDS SUCH AS PETROL,
KEROSENE, OR ENGINE OIL TO START OR REKINDLE THE FIRE.
WARNING: DO NOT USE AEROSOLS OR PLACE AEROSOL CANS IN THE
VICINITY OF THIS APPLIANCE WHEN Ш IS OPERATING. |
THIS APPLIANCE HAS BEEN TEST ED TO AUSTRALIAN STANDARDS USING
HARDWOOD ONLY. PINE CAN BE USED AS KINDLING FOR STARTING THE
FIRE BUT SHOULD NOT BE USED CONSTANTLY.
IN THE EVENT OF A SOOT OR CREOSOTE FIRE (FLUE FIRE) ENSURE DOOR IS
KEPT CLOSED AND CLOSE AIR CONTROL TO MINIMUM SETTING.
THE USE OF SOME TYPES OF PRESERVATION ~ TREATED WOOD AS A FUEL
CAN BE HAZARDOUS.
THIS APPLIANCE MUST NOT BE OPERATED AS AN OPEN FIRE.
THIS APPLIANCE MUST NOT BE OPERATED WITH A CRACKED GLASS.
REPLACEMENT GLASS IS AVAILABLE FROM YOUR KEMLAN RETAIL OUTLET.
Ss pe ci atists in f ire place design & manufacture
ME Head Office: 59 Pineapple Street (PO Box 259) Zillmere Queensland 4034
Laia E | | Telephone: (07) 3263 8488 Facsimile: (07) 3263 6452 www.kemlan.com
ESTABLISHED 1969 Business hours: Monday to Thursday 7.30am-4.00pm * Friday 7.30am-2.00pm
ABN 43 003 209 961 : |
(xii) CURING THE PAINT: YOUR STOVE HAS BEEN PAINTED WITH THE HIGHEST
QUALITY SILICONE STOVE PAINT AND HAS SPECIAL BREAK-IN PROCEDURES
TO CURE IT WITH HEAT AND MAKE IT HARD.
Ventilate the house during the first three times the stove is used. The paint on
the stove will give off smoke heavy with carbon dioxide and has an odour
Without adequate ventilation, concentrations of smoke could irritate, or be
upsetting, so open doors and windows and use a fan if necessary. After these
initial bums the paint will be cured and there should be no more smoke.
Don't touch the surface. It will be soft and gummy during this paint curing
phase. Once cured, it will not be soft again.
Most stoves cure with 3 bums. The first 2 should be 250°F for 20 minutes, or
about half a normal fire. Let the stove cool down between bums. The last fire
should be 500% to 700% for at least 45 minutes. The point being, cure
slowly without a hot fire.
Stoves with a cooler surface temperature and those that have been painted
with another colour before, will take longer to cure.
Curing can usually be observed by the effect of the paint tuming flat as the
heat radiates out from hotter parts of the stove.
So....
Ventilate well
Do not touch during curing
Curewith3 fires —ù
| Call your dealer for any questions.
MAINTENANCE
Liv) THE FLUE SYSTEM MUST BE KEPT CLEAN AND IN GOOD CONDITION
BECAUSE SOOT, CREOSOTE AND ASH MAY ACCUMULATE. —
(xv) EXCESS ASH SOULD BE REMOVED. DISPOSE OF THE ASH IN A STEEL
CONTAINER WITH A TIGHTLY FITTING LID AND MOVED OUTDOORS
IMMEDIATELY. DO NOT USE A PLASTIC OR AN INFLAMMABLE
CONTAINER. ОО
(си) CAUTION: CRACKED AND BROKEN COMPONENTS, eg GLASS PANELS
OR FIRE BRICKS, MAY RENDER THE INSTALLATION UNSAFE.
(xvii) ALL PARTS AND REPLACEABLE COMPONENTS ARE AVAILABLE
| THROUGH YOUR KEMLAN RETAIL OUTLET.
10
m a n u f a ct
d | | - Kemlan Industries Pty Ltd |
E Е Head Office: 59 Pineapple Street (PO Box 259) Zillmere Queensland 4034
ESTABLISHED 1969 Telephone: (07) 3263 8488 Facsimile: (07) 3263 6452 www.kemlan.com
ABN 43 003 209 961 Business hours: Monday to Thursday 7.30am-4.00pm * Friday 7.30am-2.00pm
Email: [email protected] |
FAN OPERATION
KEMLAN C24 MK IT
For appliance fitted with an optional fan.
3 Speed Fan
Air Inlet Setting o Fan Speed
Boost High | Low
High Yes Yes Yes
Medium | No Yes Yes
Low No - No — Yes
ia lists
EEE EA: a
design manuf act yg
.. Kemlan Industries Pty Ltd |
on œr Head Office: 59 Pineappie Street (PO Box 259) Zilimere Queensland 4034
E 1 Y Y e 4 | 969
ABN 43 003 209 961
Telephone: (07) 3263 8488 Facsimile: (07) 3263 6452 www.kemlan.com
Business hours: Monday to Thursday 7.30am-4.00pm * Friday7.30am-2.00pm
Email: [email protected]
WARRANTY
1. Kemian wood heaters carry a warranty on the 6mm firebox for a period of ten (10) years.
2. This warranty also covers other components of the heater for a period of one (1) year. These
components include the baffle plate, handle assembly, and fan.
3. Kemlan's warranty covers the wood heaters against defects in materials and manufacture.
4. This warranty does not cover —
4.1 Failure to comply with manufacturer's operation instructions.
4.2 Normal wear and tear or damage caused by incorrect installation.
4.3 Any form of rust and/or corrosion to the painted finish of the heater. |
4.4 Damage to the glass in the door, if the damage is caused by impact or misuse.
4.5 The cost of collection and delivery of the wood heater and/or parts. a
4.6 Damage caused by water ingress.
4.7 Cost of removal of defective heater or re-installation of replacement heater.
5. Claims —
51 (1) Kemian wilt provide a full replacement of the heater in the first five years after installation.
(11) Replacement in the subsequent five years (i.e. sixth to tenth year : after installation will be on
the following basis.
Owner will pay twenty percent of purchase price if the claim is made in the sixth year and a further
ten percent per year in every subsequent year to a maximum of fifty percent of the purchase price
of the heater. | |
5.2 Replacement of heater subject to all conditions in section four of warranty.
5.3 Should any defects occur, contac the Kemian distributor from whom you purchased the heater.
5.4 Under this warranty the defective parts will be repaired or replaced at Kemlan s option, free of
charge. |
6. The fireplace installation must comply with the relevant local statutes, ordinances, regulations and
by- -laws.
PLEASE COMPLETE AND RETAIN THIS SECTION FOR YOUR RECORDS
Purchased from: Ce erre TE DEE
Address: ET ST N i Lanta eee eee ee eee es La
Mate of Purchase: oo eee caca LA aa ae

advertisement

Key Features

  • 6mm firebox
  • powerful fan
  • adjustable air inlet
  • safety features
  • easy to operate
  • efficient heat distribution

Frequently Answers and Questions

How do I start the fire?
Start by crumpling newspaper into a ball and placing it on the firebrick lined floor of the firebox. Then, add kindling, and light the paper. Once the kindling is ablaze, add larger pieces of hardwood, adjusting the air inlet control as needed.
What type of wood should I use?
It's best to use dry, seasoned hardwood. Pine can be used as kindling but should not be used constantly. Avoid using treated wood as fuel.
How do I clean the appliance?
Clean the appliance when it's cool. Remove excess ash, clean the glass with ash and a damp cloth, and dust the painted surfaces. Make sure to inspect and clean the flue system regularly.
How often should I clean the flue system?
The flue system should be inspected and cleaned at least once every 12 months, preferably before the start of the winter season.