- Computers & electronics
- Software
- Software manuals
- Thermo Fisher Scientific
- GeneMapper ID-X
- Installation Guide
- 74 Pages
Thermo Fisher Scientific GeneMapper ID-X Installation Guide
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
▼
Scroll to page 2
of
74
INSTALLATION GUIDE GeneMapper®ID-X Software Version 1.5 Publication Number 100031706 Revision A For Research, Forensic, Paternity, and Cell Line Authentication. Not for use in diagnostic and therapeutic applications. The information in this guide is subject to change without notice. DISCLAIMER LIFE TECHNOLOGIES CORPORATION AND/OR ITS AFFILIATE(S) DISCLAIM ALL WARRANTIES WITH RESPECT TO THIS DOCUMENT, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT. TO THE EXTENT ALLOWED BY LAW, IN NO EVENT SHALL LIFE TECHNOLOGIES AND/OR ITS AFFILIATE(S) BE LIABLE, WHETHER IN CONTRACT, TORT, WARRANTY, OR UNDER ANY STATUTE OR ON ANY OTHER BASIS FOR SPECIAL, INCIDENTAL, INDIRECT, PUNITIVE, MULTIPLE OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH OR ARISING FROM THIS DOCUMENT, INCLUDING BUT NOT LIMITED TO THE USE THEREOF. Limited Use Label License No. 540: Sequencing or Fragment Analysis Intellectual Property for Human Identity Testing Software Notice to Purchaser: No right to resell this software product, any upgrades, modified versions, updates, additions, copies, or any of its components is conveyed expressly, by implication, or by estoppel. This software product may be used to perform internal research and development for the sole benefit of the purchaser; provided, however, that Life Technologies Corporation (“LTC”) does not convey any right or license, whether expressly, by implication, by estoppels, or otherwise, under any LTC patents that claim DNA sequencing or fragment analysis methods, to the purchaser by the purchase of this software product to use such DNA sequencing or fragment analysis methods. This software product is not for use in commercial applications of any kind, including, without limitation, quality control and commercial services such as reporting the results of purchaser’s activities for a fee or other form of consideration, except as follows. A limited license to use the DNA sequencing or fragment analysis methods covered by such patents can be obtained for certain research and development activities (a) through the purchase of certain LTC reagents that convey rights for commercial use (e.g., LTC kits for performing human identity testing and LTC kits for performing in vitro diagnostics testing) when such reagents are used on an authorized LTC instrument, or (b) directly from LTC. In addition, LTC grants the purchaser a limited right to use this software product in conjunction with: (1) a second product purchased from LTC or that conveys rights for commercial use (e.g., LTC kits for performing human identity testing and LTC kits for performing in vitro diagnostics testing) and (2) an authorized LTC instrument that conveys rights for commercial use to perform services on a fee per test or contract basis. For information on obtaining additional rights, please contact [email protected] or Out Licensing, Life Technologies, 5791 Van Allen Way, Carlsbad, California 92008. GeneMapper®ID-X Software v1.5 has undergone a verification process pursuant to Life Technologies Corporation and/or its affiliate(s) internal quality process. However, we recommend that customers installing or using GeneMapper®ID-X Software v1.5 perform any internal validation testing they deem necessary according to relevant guidelines. Each laboratory is solely responsible to ensure that its GeneMapper®ID-X Software v1.5 satisfies or will satisfy SWGDAM Guidelines or other applicable guidelines and is fit for each laboratory’s applications. This product includes software developed by the Apache Software Foundation. This product includes software developed by the ExoLab Project. JNIRegistry is copyrighted © by ICE Engineering, Inc. TRADEMARKS All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. Microsoft and Windows are trademarks of Microsoft Corporation. Intel and Core are trademarks of Intel Corporation. Oracle is a trademark of Oracle Corporation. © 2015 Thermo Fisher Scientific Inc. All rights reserved. Contents About this guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Chapter 1 Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Start here: Getting the most out of this guide . . . . . . . . . . . . . . . . 2 Installation options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 New full or client installations . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Upgrade full or client installations . . . . . . . . . . . . . . . . . . . . . . 3 Chapter 2 Installation Requirements. . . . . . . . . . . . . . . . . . . . . . . 5 Full installation computer requirements . . . . . . . . . . . . . . . . . . . . . 6 Client installation computer requirements . . . . . . . . . . . . . . . . . . . 7 Verifying your computer setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Analyzers and compatible software . . . . . . . . . . . . . . . . . . . . . . . . 9 Chapter 3 Performing Pre-Installation Procedures . . . . . . . . . . 11 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Check user access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Check Local status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Check Administrator privileges . . . . . . . . . . . . . . . . . . . . . . . 14 Modify antivirus, firewall, and network computer settings . . . . . . 15 Export data objects and settings from the current version of GeneMapper® ID-X Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Uninstall GeneMapper® ID-X Software or Oracle® software . . . . 16 Check notification settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Check Microsoft .NET Framework version . . . . . . . . . . . . . . . . . . 17 Restart the computer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Obtain the GeneMapper® ID-X Software host computer name . . 18 GeneMapper® ID-X Software v1.5 Installation Guide 3 Chapter 4 Installing the v1.5 Software . . . . . . . . . . . . . . . . . . . . 19 General installation instructions . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Performing a full installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Full installation requirements . . . . . . . . . . . . . . . . . . . . . . . . . 21 Installing the Full GeneMapper® ID-X Software . . . . . . . . . . 21 Performing a client installation . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Client installation requirements . . . . . . . . . . . . . . . . . . . . . . . 23 Installing the Client GeneMapper® ID-X Software . . . . . . . . . 23 Chapter 5 Performing Post-Installation Procedures . . . . . . . . . 27 Reset file and folder permissions after installation (Clientinstallation) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Reset antivirus, firewall, and network computer settings . . . . . . 29 Register the GeneMapper® ID-X Software . . . . . . . . . . . . . . . . . . 30 Logging into GeneMapper® ID-X after installation . . . . . . . . . . . . 31 Connecting to a new host . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Checking concurrent access settings for client computers . . . . . 34 Logging out of the GeneMapper® ID-X Software . . . . . . . . . . . . . 35 Additional post-installation tasks . . . . . . . . . . . . . . . . . . . . . . . . . 36 Appendix A Troubleshooting the Installation . . . . . . . . . . . . . . . 37 Symptoms and causes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Troubleshooting tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Canceling an installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 General installation solutions . . . . . . . . . . . . . . . . . . . . . . . . . 41 Troubleshooting tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Interdepartmental forms . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Appendix B Glossary of Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Appendix C Documentation and support . . . . . . . . . . . . . . . . . . 61 Related documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 4 GeneMapper® ID-X Software v1.5 Installation Guide How to obtain support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Limited product warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 GeneMapper® ID-X Software v1.5 Installation Guide 5 6 GeneMapper® ID-X Software v1.5 Installation Guide About this guide Revision history Revision Date A February 2015 GeneMapper® ID-X Software v1.5 Installation Guide Description New document for v1.5 software. Replaces v1.2 Pub. no. 4425023. 7 About this guide Revision history 8 GeneMapper® ID-X Software v1.5 Installation Guide Chapter 1 Getting Started Chapter 1 Getting Started This chapter covers: ■ Start here: Getting the most out of this guide . . . . . . . . . . . . . . 2 ■ Installation options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Chapter 2 Installation Requirements Chapter 3 Performing Pre-Installation Procedures Chapter 4 Installing the v1.5 Software Chapter 5 Performing PostInstallation Procedures GeneMapper® ID-X Software v1.5 Installation Guide 1 Chapter 1 Getting Started Start here: Getting the most out of this guide Start here: Getting the most out of this guide To get started: 1. Read through Chapter 1 to become familiar with your installation options. 2. See Chapter 2 for general installation requirements. 3. See Chapter 3 for pre-installation instructions. 4. See Chapter 4 for installation instructions. 5. See Chapter 5 for post-installation instructions. 6. See Appendix 6, Troubleshooting the Installation for troubleshooting instructions. 7. See Appendix 7, Glossary of Terms, for a definition of terms used frequently in this manual. After you have read the applicable chapters in this guide and are installing your software, refer to the GeneMapper® ID-X Software Administrator’s Guide for information on configuring the GeneMapper® ID-X Software administrative features and electronic data chain of custody systems. 2 GeneMapper® ID-X Software v1.5 Installation Guide Chapter 1 Getting Started Installation options Installation options Installation options for the GeneMapper® ID-X Software are based on: • The Windows® 7 operating system installed (32-bit or 64-bit) • The GeneMapper® ID or GeneMapper® ID-X Software currently installed • Your database-sharing requirements. You can either install a full version of the software, which consists of both the GeneMapper ID-X software and the database, or you can install a client version of the software, which consists only of the GeneMapper ID-X software. The full version on a computer can function as the database host for the client. Multiple clients can connect to the same database through a network connection for easy data sharing. New full or client installations A new full or client installation requires a computer with Windows® 7 64-bit operating system. When you start the software for the first time, you must enter the registration code provided with the new software. Upgrade full or client installations An upgrade full or client installation requires a computer with Windows® 7 64-bit operating system. Before installing the new software, you must export data from the host computer, then uninstall the current software from both host and client computers. During the installation, you must enter the registration code for your current version of software. When you start the new software for the first time, you must enter the registration code provided with the new software. GeneMapper® ID-X Software v1.5 Installation Guide 3 Chapter 1 Getting Started Installation options Is the GeneMapper® ID-X Software installed on the computer? Perform a new full or client installation NO YES Manually uninstall the GeneMapper® ID-X Software Export* projects, analysis methods, and size standards Perform a full or client installation *Use GeneMapper ID-X Manager to export. Database backup files (.dmp) from an older version of software cannot be restored to a newer version of software. 4 GeneMapper® ID-X Software v1.5 Installation Guide Chapter 2 Installation Requirements This chapter covers: Chapter 1 Getting Started ■ Full installation computer requirements . . . . . . . . . . . . . . . . . 6 ■ Client installation computer requirements . . . . . . . . . . . . . . . 7 ■ Verifying your computer setup . . . . . . . . . . . . . . . . . . . . . . . . 8 Chapter 2 ■ Analyzers and compatible software. . . . . . . . . . . . . . . . . . . . . 9 Installation Requirements Chapter 3 Performing Pre-Installation Procedures Chapter 4 Installing the v1.5 Software Chapter 5 Performing PostInstallation Procedures GeneMapper® ID-X Software v1.5 Installation Guide 5 Chapter 2 Installation Requirements Full installation computer requirements Full installation computer requirements Requirements Table 2 shows the recommended computer configurations for a new full installation (the GeneMapper® ID-X Software and database). Note: To install the GeneMapper ID-X software, you need a local user account with administrative privileges. You can run the computer on regional settings but you need an English Operating System. Table 2 Computer requirements for a new full installation Component Configuration IMPORTANT! Avoid installing the software on a computer with other Oracle® or SQLPlus applications and clients. If you must run other applications, install GeneMapper ID-X first. Intel® Core™ i3-3240 processor, 3.4 GHz (or newer) 8GB of RAM 10 GB free disk space 20/48X IDE CD-ROM 10/100 NIC with RWU (internal) Windows® 7 64-bit operating system (SP1) Computer and operating system 64-bit • • • • • • Monitor • 1024 × 768 pixel resolution • 19-inch color monitor Ethernet Capability • Network card for database installation • TCP/IP must be installed before database installation Note: GeneMapper® ID-X software is validated to run on Intel® Core™ i7-4810MQ computers. Required time for full installation 6 The amount of time required to perform a full installation is approximately 1 hour, depending on the speed of the computer. GeneMapper® ID-X Software v1.5 Installation Guide Chapter 2 Installation Requirements Client installation computer requirements Client installation computer requirements Requirements The recommended computer configuration for a client installation (GeneMapper® ID-X Software only) is the same as the requirements for a full installation shown in Table 2. Note: To log in to the GeneMapper ID-X software, you need a local user account with administrative privileges. For sites outside the U.S., you may need to change regional settings to U.S. settings following software installation. Required time for client Installation Optimizing computer performance The amount of time required to perform a client installation is approximately 15 minutes. For recommendations on the number of client connections to use per host to optimize computer performance, contact us. GeneMapper® ID-X Software v1.5 Installation Guide 7 Chapter 2 Installation Requirements Verifying your computer setup Verifying your computer setup 1. Click , right-click Computer, then select Properties. Operating system (OS) Latest Service Pack installed Microprocessor type and speed Installed memory System type 8 GeneMapper® ID-X Software v1.5 Installation Guide Chapter 2 Installation Requirements Analyzers and compatible software Analyzers and compatible software Instrumentation Table 3 lists Applied Biosystems® Genetic Analyzer instruments and the corresponding Data Collection and operating system software that are supported by the GeneMapper® ID-X Software Table 3 Genetic analyzers and compatible software Genetic Analysis Instrument Applied Biosystems® 3500 Series Genetic Analyzer 310 Genetic Analyzer Applied Biosystems® 31xx Genetic Analyzer Applied Biosystems® 3730 Genetic Analyzer ‡ Data Collection Software 3500 Data Collection v1.0, v2.0, or v3.0 310 Data Collection v3.0 or v3.1 3130/3130xl Data Collection v3.0 or v4.0 3730 Data Collection v3.0 or v4.0 ‡ The 3730 Genetic Analyzer does not include the 3730xl 96-capillary configuration. The 48-capillary configuration is validated for analysis of data generated from Identifiler® kits using single-source samples only. GeneMapper® ID-X Software v1.5 Installation Guide 9 Chapter 2 Installation Requirements Analyzers and compatible software 10 GeneMapper® ID-X Software v1.5 Installation Guide Chapter 3 Performing Pre-Installation Procedures This chapter covers: Chapter 1 Getting Started ■ Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 ■ Check user access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 ■ Modify antivirus, firewall, and network computer settings . 15 Chapter 2 Installation Requirements ■ Export data objects and settings from the current version of GeneMapper® ID-X Software . . . . . . . . . 15 ■ Uninstall GeneMapper® ID-X Software or Oracle® software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Chapter 3 Performing Pre-Installation Procedures ■ Check notification settings . . . . . . . . . . . . . . . . . . . . . . . . . . 16 ■ Check Microsoft .NET Framework version . . . . . . . . . . . . . 17 ■ Restart the computer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 ■ Obtain the GeneMapper® ID-X Software Chapter 4 host computer name. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Installing the v1.5 Software Chapter 5 Performing PostInstallation Procedures GeneMapper® ID-X Software v1.5 Installation Guide 11 Chapter 3 Performing Pre-Installation Procedures Overview Overview Before installing GeneMapper ID-X software on computers that have an earlier version of software installed, you must export the data objects (projects, analysis methods, etc.) as a means of backing up the data, then uninstall the existing software. Check user access You must log on to the local computer using a local account with administrator privileges (read, write, and execute [rwx] permissions). The local computer is typically identified in the log in dialog box by the text “(this computer)” after the computer name A local computer account may be different from the account you normally use to log in to the computer. The local account: • Can not include network domain policies that restrict access to the install drive of the local computer account. • Can not restrict access to operating system firewall or other security configurations. 12 GeneMapper® ID-X Software v1.5 Installation Guide Chapter 3 Performing Pre-Installation Procedures Check user access Check Local status Control PanelUser Accounts. Click Configure advanced user profile properties. 1. Select 2. Select your local user account and ensure that the Type is Local. GeneMapper® ID-X Software v1.5 Installation Guide 13 Chapter 3 Performing Pre-Installation Procedures Check user access Check Administrator privileges 1. Right-click My Computer, then select Manage. 2. In the Computer Management dialog box, click Local Users and Groups, then double-click Groups. 3. Double-click Administrators. Ensure that your local account is listed in the Administrators group. 14 GeneMapper® ID-X Software v1.5 Installation Guide Chapter 3 Performing Pre-Installation Procedures Modify antivirus, firewall, and network computer settings Modify antivirus, firewall, and network computer settings 1. Disable Antivirus software (including anti-malware software) before the installation. 2. Disable Firewalls before the installation. 3. Disable all network connections before the installation: Go to Control PanelNetwork and Sharing center. Double-click a connection, then select Disable. 4. Disable all virtual network adapters are disabled (refer to manufacturer documentation for instructions). Export data objects and settings from the current version of GeneMapper® ID-X Software • Computers running a full version of GeneMapper® ID-X Software (contains the database) or GeneMapper® ID Software v3.2: Export the data objects or settings you would like to restore after upgrade – Analyzed projects, analysis methods, plot settings, etc.). – Profiles from the Profile Manager (v1.5 software supports import of text files containing profiles) For information, refer to the GeneMapper® ID-X Software online help. • Computers running a client version of GeneMapper® ID-X Software: Export is not required. GeneMapper® ID-X Software v1.5 Installation Guide 15 Chapter 3 Performing Pre-Installation Procedures Uninstall GeneMapper® ID-X Software or Oracle® software Uninstall GeneMapper® ID-X Software or Oracle® software Uninstall GeneMapper® ID-X Software, any other programs that use Oracle databases, and any existing versions of Oracle databases, whether Applied Biosystems products or products from other companies. Go to StartControl PanelAdd or Remove Programs. After uninstallation, ensure that the GeneMapper® ID-X Software is uninstalled (go to StartControl PanelAdd or Remove Programs and make sure it is not listed. If it is still listed, manually uninstall the software (see “If the GeneMapper® ID-X Software is still listed after uninstalling” on page 42). Check notification settings Control PanelUser Accounts. Click Change User Account Settings. 1. Select 2. In the User Account Control Settings, drag the slider to the bottom position Never Notify. 16 GeneMapper® ID-X Software v1.5 Installation Guide Chapter 3 Performing Pre-Installation Procedures Check Microsoft .NET Framework version Check Microsoft .NET Framework version Ensure that a version of 3.5 or later is installed on the computer: 1. Select Control PanelUser Programs and Features. 2. Scroll down and determine if a version of 3.5 or later is installed. (There may be multiple versions installed. Do not remove any versions of the software.) Version 3.5 or higher is required 3. If a version of 3.5 or later is not installed, download Microsoft .NET Framework 4 from Microsoft.com. Ensure that the download you select supports 32-bit (x86) or 64-bit (x64) as appropriate for your computer. 4. Install the software. 5. After installation completes, verify the Microsoft .NET Framework 4 was successfully installed (select PanelUser Programs and Features). GeneMapper® ID-X Software v1.5 Installation Guide Control 17 Chapter 3 Performing Pre-Installation Procedures Restart the computer Restart the computer To activate the changes made in the previous sections, restart the computer before installing the software. Obtain the GeneMapper® ID-X Software host computer name Before you install the client GeneMapper® ID-X Software, obtain the name of the multi-user database host computer to enable access to the host computer from a network: 1. On the multiuser database host computer, click Computer, then select Properties. , right-click Computer name 2. Make a note of the computer name and enter this name when prompted during installation of the client GeneMapper® ID-X Software. 18 GeneMapper® ID-X Software v1.5 Installation Guide Chapter 4 Installing the v1.5 Software Chapter 1 Getting Started This chapter covers: ■ General installation instructions . . . . . . . . . . . . . . . . . . . . . . 20 ■ Performing a full installation. . . . . . . . . . . . . . . . . . . . . . . . . 20 ■ Performing a client installation . . . . . . . . . . . . . . . . . . . . . . . 23 Chapter 2 Installation Requirements ■ Resetting permissions for the installation . . . . . . . . . . . . . . . 29 Chapter 3 Performing Pre-Installation Procedures Chapter 4 Installing the v1.5 Software Chapter 5 Performing PostInstallation Procedures GeneMapper® ID-X Software v1.5 Installation Guide 19 Chapter 4 Installing the v1.5 Software General installation instructions General installation instructions IMPORTANT! If you use a computer platform that does not meet the requirements listed in Installation Requirements, you may experience difficulties during installation (new or upgrade) of GeneMapper® ID-X Software, or the software may not function properly, even if the installation proceeded successfully. Before installing the GeneMapper® ID-X Software: • Review Installation Requirements. • Log in to the local computer and have Administrator privileges when installing, un-installing, or upgrading the GeneMapper® ID-X Software. Logging in to a network domain with administrative privileges is not sufficient. • During installation (new or upgrade) of GeneMapper® ID-X Software: – Install the Full version first, then install all Client versions which will connect to the Full version database. – Allow the installation DVD to Autostart, or double-click the Setup.exe file to launch the installer. • When un-installing the GeneMapper® ID-X Software, log in using the same local user account as the one used when installing the software and follow the un-installation message prompts during the un-installation process to ensure clean uninstallation. Performing a full installation A full GeneMapper® ID-X Software installation: • Installs the GeneMapper ID-X software and database. • Enables the GeneMapper ID-X software to serve as the host for multiple client computers needing access to the database. • Upgrades only: During installation, requires you to enter the registration code for your current version of software. 20 GeneMapper® ID-X Software v1.5 Installation Guide Chapter 4 Installing the v1.5 Software Performing a full installation Full installation requirements Important reminders • DO NOT cancel an installation before the installation process is finished. If you do so, or if the installation otherwise stalls, you may need technical support to perform an uninstall. To uninstall, see “Uninstalling the GeneMapper® ID-X Software” on page 42. If uninstallation fails, contact technical support. Installing the Full GeneMapper® ID-X Software Full installation procedure 1. Insert the Full install disk into the CD drive. 2. On the splash screen, double-click Install GeneMapper ID-X Application to start the installer. 3. In the Welcome window, click Next. 4. Review the installation requirements status, then click Next. 5. Read the release notes, then click Next. 6. Click Next to install the Software to the default location. To install the GeneMapper® ID-X Software to a drive different from the default drive, select the destination folder: Select a destination folder with at least 10 GB of free space, then click Next. IMPORTANT! If you choose an invalid destination such as A: drive or CD-DVD ROM and click Next, an error message is displayed saying the drive is invalid. When you click OK the installation is stopped. To recover, click Cancel and start the installation over again, using a valid destination folder. GeneMapper® ID-X Software v1.5 Installation Guide 21 Chapter 4 Installing the v1.5 Software Performing a full installation 7. Read the current settings, then click Next to start the installation. IMPORTANT! During installation, a DOS window may open while DOS commands execute. Do not delete, close, or click the DOS window. If you accidentally click the DOS window, press the Esc key to exit the window. 8. Upgrades only: When prompted, type the registration code for your current software. 9. In the InstallShield Wizard Complete page, select Yes, I want to restart my computer now, then click Finish. When you finish the installation, proceed to Chapter 5, “Performing Post-Installation Procedures,” on page 27. 22 GeneMapper® ID-X Software v1.5 Installation Guide Chapter 4 Installing the v1.5 Software Performing a client installation Performing a client installation A client installation: • Allows the user access to the GeneMapper ID-X software without a database installed on the same computer. • Connects to one or more database hosts for access to the data stored in the database and saves data objects back to the database. • Upgrades only: During installation, requires you to enter the registration code for your current version of software. Client installation requirements Important reminders • DO NOT cancel an installation before the installation process is finished. If you do so, or if the installation otherwise stalls, you may need technical support to perform an uninstall. To uninstall, see “Uninstalling the GeneMapper® ID-X Software” on page 42. If uninstallation fails, contact technical support. • At least one full installation of the same software version must be performed on another computer for it to act as the database host for the client. • Users are required to have a valid user name and password with an account on the database host computer. • You must obtain the name of the database host computer to enable access to the host computer from a network: Right-click My Computer on the database host computer, select Properties, then select the Computer Name tab to view and record the full computer name. You are required to enter this name during installation (see page 18). Installing the Client GeneMapper® ID-X Software 1. Insert the Client Install CD into the CD drive. GeneMapper® ID-X Software v1.5 Installation Guide 23 Chapter 4 Installing the v1.5 Software Performing a client installation 2. On the splash screen, double-click Install GeneMapper ID-X Client to start the installer. 3. In the Welcome window, click Next. 4. Review the installation requirements status, then click Next. 5. Read the release notes, then click Next. 6. When prompted, enter the GeneMapper® ID-X Software (GM) host (server) computer name, then click Next. 7. After the installer establishes a connection with the multi-user database computer, click OK to continue. 24 GeneMapper® ID-X Software v1.5 Installation Guide Chapter 4 Installing the v1.5 Software Performing a client installation 8. To install the GeneMapper® ID-X Software to a drive on the client computer other than the default drive, select the destination folder and verify that the boot drive (drive on which the Windows operating system is installed) contains at least 250 MB of available free space. IMPORTANT! If you choose an invalid destination such as A: drive or CD-DVD ROM and click Next, an error message is displayed saying the drive is invalid. When you click OK the installation is stopped. To recover, click Cancel and start the installation over again, using a valid destination folder.Read the current settings, then click Next to start the installation. IMPORTANT! During installation, a DOS window may open while DOS commands execute. Do not delete, close, or click the DOS window. If you accidentally click the DOS window, press the Esc key to exit the window. 9. Upgrades only: When prompted, type the registration code for your current software. 10. Remove the installation CD from the CD drive. 11. In the InstallShield Wizard Complete window, select Yes, I want to restart my computer now, then click Finish. 12. Repeat the procedure for additional client installations. When you finish all client installations, proceed to Chapter 5, “Performing Post-Installation Procedures,” on page 27. GeneMapper® ID-X Software v1.5 Installation Guide 25 Chapter 4 Installing the v1.5 Software Performing a client installation 26 GeneMapper® ID-X Software v1.5 Installation Guide Chapter 5 Performing Post-Installation Procedures This chapter covers: Chapter 1 Getting Started ■ Reset file and folder permissions after installation (Client installation) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 ■ Reset antivirus, firewall, and network computer settings . . . 29 Chapter 2 Installation Requirements ■ Register the GeneMapper® ID-X Software . . . . . . . . . . . . . . 30 ■ Logging into GeneMapper® ID-X after installation . . . . . . . 31 ■ Connecting to a new host . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 ■ Checking concurrent access settings for client computers . . 34 Chapter 3 Performing Pre-Installation Procedures ■ Logging out of the GeneMapper® ID-X Software. . . . . . . . . 35 ■ Additional post-installation tasks . . . . . . . . . . . . . . . . . . . . . 36 Chapter 4 Installing the v1.5 Software Chapter 5 Performing PostInstallation Procedures GeneMapper® ID-X Software v1.5 Installation Guide 27 Chapter 5 Performing Post-Installation Procedures Reset file and folder permissions after installation (Client installation) Reset file and folder permissions after installation (Client installation) The client installer specifies folder privileges at the time of the GeneMapper® ID-X Software installation. However, the NTFS permissions set by the system administrator may not allow the GeneMapper® ID-X Software to access the GeneMapper folder following installation. Before you run the software, check the permissions to make sure that the GeneMapper® ID-X Software can access the GeneMapper folder. If you do not have the required permissions, you may see a “can't access file” or “..\GeneMapper_Preferences (Access is denied)” error message when using the software. To set the privileges manually, either before running the software or in the event of an error message: 1. Right-click the AppliedBiosystems folder. 2. Select Properties, then click the Security tab. 3. In the top pane, select Users. 4. Click Edit. 28 GeneMapper® ID-X Software v1.5 Installation Guide Chapter 5 Performing Post-Installation Procedures Reset antivirus, firewall, and network computer settings 5. In the bottom pane, select Full Control. Reset antivirus, firewall, and network computer settings Reset the antivirus, firewall, and network settings you changed for installation. GeneMapper® ID-X Software v1.5 Installation Guide 29 Chapter 5 Performing Post-Installation Procedures Register the GeneMapper® ID-X Software Register the GeneMapper® ID-X Software Register the GeneMapper® ID-X Software the first time you start the software on each computer. The registration code is on the registration card packaged with the software. 1. Click All ProgramsApplied Biosystems GeneMapperGeneMapper ID-X. 2. Complete the Registration dialog box: 3. Click OK. 30 GeneMapper® ID-X Software v1.5 Installation Guide Chapter 5 Performing Post-Installation Procedures Logging into GeneMapper® ID-X after installation Logging into GeneMapper® ID-X after installation 1. If the Login dialog box is not displayed in the desktop, Click All ProgramsApplied Biosystems GeneMapperGeneMapper ID-X. 2. In the Login to GeneMapper ID-X dialog box, enter or select “gmidx” as the administrator account user name and the temporary password, “password”, then click OK. 3. If prompted, specify a new password. Keep a record of the new password. Click OK. Note: The gmidx account requires you to set a new password when you log in for the first time. If you follow this procedure after first log in, the passwords for the accounts listed may be different from the passwords listed in this guide. IMPORTANT! Do not lose the password for the gmidx account. We cannot retrieve these passwords. 4. Review the license agreement and product warranty, then click Accept. GeneMapper® ID-X Software v1.5 Installation Guide 31 Chapter 5 Performing Post-Installation Procedures Connecting to a new host Connecting to a new host If you install more than one multi-user database computer, any v1.5 client computer can connect to any of the databases if the client is on the same network as the database computers. Note: All client computers connecting to multi-user database computers must be running the same version of GeneMapper ID-X Software. IMPORTANT! Do not attempt to connect a v1.4 client (or any earlier version) to a v1.5 database. Doing so will lock the database and will require assistance from a service representative to unlock. Users must set up separate user accounts on each multi-user database computer that they wish to access. Note: For detailed information on setting up user accounts, see the GeneMapper® ID-X Software Administrator’s Guide. To make the multi-user database computers available to client computers, perform the following steps for each client computer: 1. Click New Host in the Login to GeneMapper ID-X dialog box. 2. Complete the information in the New Host dialog box: 32 GeneMapper® ID-X Software v1.5 Installation Guide Chapter 5 Performing Post-Installation Procedures Connecting to a new host a. In the Host Name field, enter the full computer name or IP address of the multi-user database host you want to access. If the GeneMapper® ID-X Software cannot connect to the database host, the error message “You have entered an invalid host” is displayed. Click OK to exit, then reenter the database host information. b. Select the applicable machine type. c. Click OK. The Login window is updated to include the name of the new database host. The User Name list reflects the user accounts on the new database host. See the GeneMapper® ID-X Software Administrator’s Guide for additional information. GeneMapper® ID-X Software v1.5 Installation Guide 33 Chapter 5 Performing Post-Installation Procedures Checking concurrent access settings for client computers Checking concurrent access settings for client computers If your configuration includes client computers: 1. Open a project on the computer containing the database. 2. Open the same project on a client computer. If a message is displayed on the client computer indicating the the project is read-only, concurrent access settings are properly specified and no further action is required. 3. If no message is displayed on the client computer, do the following: a. Contact your network administrator and ask if “Multicast” functionality is enabled on the network. b. On the computer containing the database, navigate to x:\AppliedBiosystems\GeneMapperID-X\service\bin folder. c. If Multicast functionality is enabled, double-click SwitchToMulticast.exe. If Multicast functionality is not enabled, double-click SwitchToUnicast.exe. 4. Repeat step 1 and step 2 and ensure that a message is displayed on the client computer indicating the project is read-only. 34 GeneMapper® ID-X Software v1.5 Installation Guide Chapter 5 Performing Post-Installation Procedures Logging out of the GeneMapper® ID-X Software Logging out of the GeneMapper® ID-X Software You can close the GeneMapper® ID-X Software by: • Selecting FileLogout. • Selecting FileExit. • Clicking (Close). When you log out of the GeneMapper® ID-X Software with a project that has unsaved changes, the software prompts you to save or discard the changes you made since the last time you updated the project. If you used the FileLogout command, the login window re-opens after you select either Yes or No. The GeneMapper ID-X Software closes completely if you use either FileExit or (Close). GeneMapper® ID-X Software v1.5 Installation Guide 35 Chapter 5 Performing Post-Installation Procedures Additional post-installation tasks Additional post-installation tasks Importing application data Creating user accounts and configuring administrative functions 36 Select ToolsGeneMapper ID-X Manager. Then in the GeneMapper ID-X Manager window, click each tab to import the corresponding objects into GeneMapper® ID-X Software. For information on creating user accounts and configuring the Security Manager, Audit Manager, and E-Signature Administrator, see the GeneMapper® ID-X Software Administrator’s Guide. GeneMapper® ID-X Software v1.5 Installation Guide Appendix 6 Troubleshooting the Installation This appendix covers: ■ Symptoms and causes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 ■ Troubleshooting tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 ■ Troubleshooting tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 GeneMapper® ID-X Software v1.5 Installation Guide 37 Appendix B Troubleshooting the Installation Symptoms and causes Symptoms and causes Symptom ORA-12528 and ORA-12541 Oracle® errors displayed during installation “GeneMapper® ID-X software requires Microsoft .NET Framework 3.5 or greater. You can download from Microsoft.” Possible cause Action 32-bit computers only: Virtual memory setting needs adjustment. See Check virtual memory settings (32-bit only) on page 51. Problem with Oracle® software installation. Contact Technical Support. Incorrect Microsoft® .NET Framework version 1. Cancel the installation. 2. Install the required version. See Check Microsoft .NET Framework version on page 17. 3. Start the installation again. ® GeneMapper ID-X Software will not start after installation 38 Uninstallation of the previous version of GeneMapper® ID-X Software failed. Uninstall the software. See Uninstalling the GeneMapper® ID-X Software on page 42. Note: In most cases, uninstallation should succeed. However, third-party software, firewall interference, and other situations may interfere with successful uninstallation. If the problem persists, contact Technical Support. GeneMapper® ID-X Software v1.5 Installation Guide Appendix B Troubleshooting the Installation Symptoms and causes Symptom Possible cause Action “No databases found” message Network security settings are preventing communication between the user interface and the Oracle® database. Modify network security settings. See Enable communication with port 1521 on page 43. Virtual network adapters are enabled. Disable virtual network adapters. If the problem persists, contact Technical Support. “The database connection has been lost. Please restart the application. This message may appear multiple times.” message Full installation regularly loses connection with the database Network communication is interrupted. Restart the software. Wireless network in use. Use a cable-based network system, such as a CAT5e network, with plug-in Network Interface Controller (NIC) cards. Anti-virus software is interfering with communication. Use less restrictive anti-virus settings. Restart Oracle services (see Restart Oracle services on page 47). Disable, replace, or remove the anti-virus software. Use a cable-based network system, such as a CAT5e network, with plug-in Network Interface Controller (NIC) cards. Unstable network connections. Contact your network administrator. Use a cable-based network system, such as a CAT5e network, with plug-in Network Interface Controller (NIC) cards. Client installation “cannot access file” or “..\ GeneMapper_Preferences (Access is denied)” message File and folder permissions are not set correctly on the client computer. GeneMapper® ID-X Software v1.5 Installation Guide Set permissions. See Reset file and folder permissions after installation (Client installation) on page 28. 39 Appendix B Troubleshooting the Installation Symptoms and causes Symptom Possible cause Action Client installation regularly loses connection with the database, but full installation does not lose connection Unstable network connections. Contact your network administrator. Disk space message is displayed when you start the software The computer has limited available disk space. If possible, archive then delete data from the database. Use the Database Dashboard utility to compress the database. Note: You may see a discrepancy between the space used in the Database DashboardGeneMapper IDX Projects Statistics and the available free space. This discrepancy is caused when you delete projects from the GeneMapper® ID-X Software. Version error displayed when you import a panel file (this message differs from the message displayed in earlier versions of the software) The version text in the panel .txt file is not present. Edit the panel .txt file to include the text shown in the figure. Cannot access deleted audit records Restore the audit records. 1. In the Project window, select AdminAudit ManagerReport. 2. Log in to the Audit Manager. 3. In the Audit History Viewer, FileEdit Query, leave the default settings, then click OK. 4. Select FileExecute Query. 40 GeneMapper® ID-X Software v1.5 Installation Guide Appendix B Troubleshooting the Installation Troubleshooting tasks Troubleshooting tasks Canceling an installation DO NOT cancel an installation before the installation process is finished. If you do so, or if the installation otherwise stalls, you may need technical support to perform an uninstall. To uninstall, see “Uninstalling the GeneMapper® ID-X Software” on page 42. If uninstallation fails, contact technical support. General installation solutions Note: You may need to send the GeneMapper ID-X install and MSI log files to Technical Support if the troubleshooting procedures in this appendix do not solve the installation problem. If you have trouble installing the GeneMapper® ID-X Software on your computer: Task Obtaining the installation log file See page 1. Obtain the installation log file. 41 2. If necessary, uninstall the software. 42 3. If necessary, have a knowledgeable technician run the Fix It utility. 50 To obtain the installation log file, go to: x:{installdir}\AppliedBiosystems\GeneMapper ID-X where x is the drive on which the GeneMapper ID-X Software is installed and {installdir} is the user-selected installation path. • You will find 2 logs for the full installation: – GMIDXInstall.log – GMIDX_MSI.log • You will find 2 logs for the client installation: – GMIDXClientInstall.log – GMIDXClient_MSI.log GeneMapper® ID-X Software v1.5 Installation Guide 41 Appendix B Troubleshooting the Installation Troubleshooting tasks Uninstalling the GeneMapper® IDX Software 1. Restart the computer and log on using a local computer administrator account (see Check user access on page 12). 2. Ensure that no programs or applications are running. 3. Disable any antivirus software (including antimalware software). Control PanelUninstall a Program. Select GeneMapper® ID-X Software, then click Uninstall. 4. Select 5. Restart the computer and log on using a local computer administrator account. 6. Confirm that the software has been uninstalled: select Control PanelUninstall a Program. If GeneMapper® ID-X Software is still listed, go to If the GeneMapper® ID-X Software is still listed after uninstalling on page 42 below. If the IDX Software is still listed after uninstalling GeneMapper® 1. Ensure antivirus/antimalware software is disabled. Note: In some instances, the antivirus/antimalware software is automatically enabled, so you must ensure it is disabled more than one time in the procedure. 2. Confirm the Virtual Memory settings are correct (Check virtual memory settings (32-bit only) on page 51). 3. Run the Remove Oracle utility: a. Insert the GeneMapper® ID-X Software Full or Full Upgrade Installation DVD in the computer DVD drive, right-click on the drive icon, then select Explore. b. Navigate to UtilitiesRemoveOracle.exe. c. Copy RemoveOracle.exe to the desktop. d. Double-click RemoveOracle.exe (a black box appears for a few seconds and disappears). 4. Navigate to and delete the entire x:\AppliedBiosystems folder. 5. Restart the computer and log on using a local computer administrator account. 42 GeneMapper® ID-X Software v1.5 Installation Guide Appendix B Troubleshooting the Installation Troubleshooting tasks Enable communication with port 1521 The GeneMapper® ID-X Software uses port 1521 to communicate between the user interface and the Oracle database via the TCP Internet Protocol and TNS Names. On most computers, this port is enabled automatically during installation. However, if the software does not start or a “No databases found” message is displayed after installation, modify settings to enable communication with port 1521. IMPORTANT! In addition to Windows security settings, some third- party anti-virus or firewall applications may affect port 1521. If you are running, third-party anti-virus or firewall applications, modify settings for those applications to enable communication with port 1521. Control PanelSystem and SecurityWindows Firewall. Click Advanced Settings. 1. Select GeneMapper® ID-X Software v1.5 Installation Guide 43 Appendix B Troubleshooting the Installation Troubleshooting tasks 2. In the Windows Firewall with Advanced Security window, click Inbound Rules. 3. Click New Rule. 44 GeneMapper® ID-X Software v1.5 Installation Guide Appendix B Troubleshooting the Installation Troubleshooting tasks 4. Select Port, then click Next. 5. Select TCP, then type 1521 in the Specific Local Ports, then click Next. GeneMapper® ID-X Software v1.5 Installation Guide 45 Appendix B Troubleshooting the Installation Troubleshooting tasks 6. In the Action page, select Allow the connection, then click Next. 7. In the Profile page, leave the default settings selected, then click Next. 8. In the Name page, type GeneMapper IDX, then click Finish. 46 GeneMapper® ID-X Software v1.5 Installation Guide Appendix B Troubleshooting the Installation Troubleshooting tasks The Inbound Rules List is displayed with GeneMapper IDX added as a rule. The rule should be enabled by default (indicated by the presence of the Disable Rule command). 9. If Enable Rule is displayed instead of Disable Rule, click Enable Rule. Restart Oracle services If a “The database connection has been lost” message is displayed, restart Oracle services using a .bat file or manually. GeneMapper® ID-X Software v1.5 Installation Guide 47 Appendix B Troubleshooting the Installation Troubleshooting tasks Restarting with a .bat file 1. On the Full installer DVD, navigate to the Utilities folder. 2. Double-click ServicesRestart.bat. (You can also copy the file to your hard disk and start the .bat file from your hard drive.) The following window is displayed for ~2 minutes as the services restart. 3. When the window closes, start the GeneMapper® ID-X Software. 48 GeneMapper® ID-X Software v1.5 Installation Guide Appendix B Troubleshooting the Installation Troubleshooting tasks Restarting manually 1. Go to StartControlPanelAdministrative ServicesServices. 2. In the Services screen, right-click the following services, then select Restart: • OracleIFAGMIDXTNSListener • OracleMTSRecoveryService • OracleServiceIFA 3. Ensure the Startup Type is set to Automatic for each service. If it is not, right-click a service, then select Automatic for Startup Type. GeneMapper® ID-X Software v1.5 Installation Guide 49 Appendix B Troubleshooting the Installation Troubleshooting tasks 4. Start the GeneMapper® ID-X Software. Running Microsoft® Fix it utilities Run these utilities under only the following conditions: • You have attempted the uninstall procedure using the Add/Remove Program uninstall option, and • The GeneMapper® ID-X Software files were not removed or were only partially removed. 1. Go to http://support2.microsoft.com/fixit/. 2. Select Windows, then select Install or upgrade software or hardware. 3. Scroll down to Fix problems that programs cannot be installed or uninstalled, then click Run Now. 4. Follow the instructions in the wizard. When prompted, select Detect problems and let me select the fixes to apply, then select Uninstall. 50 GeneMapper® ID-X Software v1.5 Installation Guide Appendix B Troubleshooting the Installation Troubleshooting tasks 5. Select GeneMapper® ID-X Software, then click Yes when asked if you want to fix the problem. 6. A dialog will come up asking if you want to try to fix it Check virtual memory settings (32-bit only) 1. On the desktop, right-click My Computer, then click Advanced System Settings. GeneMapper® ID-X Software v1.5 Installation Guide 51 Appendix B Troubleshooting the Installation Troubleshooting tasks 2. In the System Properties dialog box, click Settings in the Performance section. 3. Click the Advanced tab, then click Change in the Virtual Memory section. 52 GeneMapper® ID-X Software v1.5 Installation Guide Appendix B Troubleshooting the Installation Troubleshooting tasks 4. In the Virtual Memory dialog box, deselect the Automatically Manage paging file size for all drives check box. Select the C: drive. Click the Custom size radio button. Specify 2046 MB for initial and 4092 for maximum size. IMPORTANT! The exact Maximum Size necessary may depend on your computer configuration. If installation still fails when using these values, or if Oracle® ORA-12528 and ORA-12541 errors are displayed, increase the Maximum size to at least 2✕ the physical memory (the minimum required for the installation of Oracle® software) up to the value shown for Space Available, then repeat the installation. To determine the physical memory for your computer, right-click My Computer on the desktop, select Properties, then look for the RAM value on the General tab. Example: If the physical memory is 3.0 GB RAM, set the Maximum Size to 6000. 5. Click Set, then click OK. These settings are not activated until you restart the computer. Restart the computer, then check virtual memory settings again to ensure that the new settings are activated. GeneMapper® ID-X Software v1.5 Installation Guide 53 Appendix B Troubleshooting the Installation Troubleshooting tools Troubleshooting tools Complete the Troubleshooting Checklist and Interdepartment Forms before contacting Technical Support for assistance. Checklist Table 6 Troubleshooting Checklist Check Information for Technical Support Summarize the problem: Can you repeat the problem? If yes, list the steps that you perform: 1. 2. 3. 4. 5. 6. 7. Personnel that you have contacted: ❏ ❏ ❏ ❏ ❏ ❏ Field Applications Specialist Field Service Engineer Technical Support Sales Representative Order Administration Other Computer specifications: • • • • • • 54 Operating system: Version: Processor: Memory: Hard disk space: Hard disk configuration: GeneMapper® ID-X Software v1.5 Installation Guide Appendix B Troubleshooting the Installation Troubleshooting tools Check Information for Technical Support Software installed: ❏ GeneMapper ID-X Software version: ❏ Other software: Computer login information: • User privileges: • Local or networked domain: Software configuration installed: ❏ Stand-alone ❏ Multi-user database Instrument and instrument computer information: • • • • • • • • Model: Data Collection Software version: Status of Data Collection services: Other software: Capillary length: Capillary lot number: Run module: Dye set: Chemistry kit or reagent, with version number: Be prepared to send to Technical Support: • • • • • • • • • Installation log file (page 41) Exported panels Exported bins Exported size standard definition Exported analysis method Sample (.fsa) files GMIDXInstall.log or GMIDXClientInstall.log PanelImportLog.txt Printed results GeneMapper® ID-X Software v1.5 Installation Guide 55 Appendix B Troubleshooting the Installation Troubleshooting tools Interdepartmental forms Answering questions in the following forms helps manage complex troubleshooting procedures. Your answers will be shared among support groups, product groups and software development teams. To address any issues that may arise when installing or running the software, please answer the applicable list of questions, and collect the necessary files before contacting Technical Support. 56 GeneMapper® ID-X Software v1.5 Installation Guide Appendix B Troubleshooting the Installation Troubleshooting tools For installation issues Collect the following files and complete the questions below: For full installation: • GMIDXInstall.log • GMIDX_MSI.log For client installation: • GMIDXClientInstall.log • GMIDXClient_MSI.log Do the computer and operating system meet the required computer specifications? (See Chapter 2, “Installation Requirements,” on page 5.) List any potential discrepancies. Did you receive any error messages or alerts? If so, what did they say? (if possible, take screen captures.) At what point during the installation process did these errors/alerts occur? How many installation attempts have you tried? Are you logged in to the local computer? Is the TCP/IP configured? Do you have administrative privileges? Is this setup stand-alone, networked, or connected to a Genetic Analyzer? GeneMapper® ID-X Software v1.5 Installation Guide 57 Appendix B Troubleshooting the Installation Troubleshooting tools For postinstallation related issues Do the computer and operating system meet the required computer specifications? (See Chapter 2, “Installation Requirements,” on page 5.) List any potential discrepancies. Problem description: Did you receive any error messages or alerts? If so, what did they say? (If possible, take screen captures.) At what point did these errors/alerts occur? Is the problem reproducible? Steps taken prior to encountering or to reproduce the problem: 1. 2. 3. 4. 5. 58 GeneMapper® ID-X Software v1.5 Installation Guide Glossary of Terms Client installation A computer installed with the GeneMapper® ID-X Software only (software with no database). A client installation computer connects to a full installation computer to access the multi-user database. Data Collection Software The software on the Data Collection computer that controls the Genetic Analyzer instrument and generates the .fsa or .hid (3500) sample files. Full installation A computer installed with both the multi-user database and GeneMapper ID-X Software. A full installation computer can be part of a multi-user database configuration, or it can be a stand-alone computer having no interaction with other computers. Genetic analyzer GMID GMID-X Local area network Multi-user database host computer The capillary electrophoresis instrument, controlled by the Data Collection Software, which generates .fsa or .hid sample files (.hid on the 3500). Abbreviation for GeneMapper® ID Software. Abbreviation for GeneMapper® ID-X Software. A communications network that serves users within a confined geographical area. A computer on which data is stored on a central, multi-user database. Commonly referred to as the host computer, from which other client computers (computers without a database) can access, analyze, and share data. GeneMapper® ID-X Software v1.5 Installation Guide 59 Glossary of Terms 60 GeneMapper® ID-X Software v1.5 Installation Guide Documentation and support Related documentation The following related documents are shipped with the system: Document Part number Description GeneMapper® ID-X Software Version 1.5 Getting Started Guide — Basic Features 100031701 Explains how to set up the software, set up a project, and analyze the example data provided with the GeneMapper® ID-X Software. GeneMapper® ID-X Software Version 1.5 Quick Reference Card — Basic Features 100031702 Provides an easy-to-follow workflow for using basic system features. GeneMapper® ID-X Software Version 1.5 Getting Started Guide — Mixture Analysis Tool 100031704 Explains how to set up the software for mixture analysis and analyze the example data provided with the GeneMapper ID-X Software. GeneMapper® ID-X Software Version 1.5 Quick Reference Card — Mixture Analysis Tool 100031705 Provides an easy-to-follow workflow for using the mixture analysis tool. GeneMapper® ID-X Software Version 1.5 Reference Guide 100031707 Describes process quality values (PQVs) and algorithms. GeneMapper® ID-X Software Version 1.5 Administrator’s Guide 100031703 Describes how to configure the administrative features of the software, maintain the GeneMapper® ID-X Software and database dashboard software, and use the command-line interface. GeneMapper® ID-X Software Version 1.5 Integration User Bulletin 100031709 Describes command line interface commands that can be scripted and used to automate GeneMapper® ID-X Software operations. GeneMapper® ID-X Software v1.5 Installation Guide 61 Documentation and support How to obtain support How to obtain support For HID support: • In the United States and Canada – send an email to [email protected], or call 888-821-4443 option 1. • Outside the United States and Canada – contact your local support office. For the latest services and support information for all locations, go to: www.lifetechnologies.com/support At the web site, you can: • Access worldwide telephone and fax numbers to contact Technical Support and Sales facilities. • Search through frequently asked questions (FAQs). • Submit a question directly to Technical Support. • Search for user documents, Material Safety Data Sheets (MSDSs), vector maps and sequences, application notes, formulations, handbooks, certificates of analysis, citations, and other product support documents. • Download .pdf documents. • Obtain information about customer training. Limited product warranty Life Technologies Corporation and/or its affiliate(s) warrant their products as set forth in the Life Technologies’ General Terms and Conditions of Sale found on Life Technologies’ website at www.lifetechnologies.com/termsandconditions. If you have any questions, please contact Life Technologies at www.lifetechnologies.com/support. 62 GeneMapper® ID-X Software v1.5 Installation Guide Index A E Applied Biosystems contacting 62 Technical Support 62 Ethernet requirements, full installation 6 exporting data projects 36 C F client installation connecting to new host 32 DOS window 25 installation time 7 installing client 23 log file 41 on non-DC computer 23 troubleshooting 38, 41 computer requirements Ethernet, full installation 6 full installation 6 monitor, full installation 6 operating system, full installation 6 verifying setup 8 computer setup verifying 8 connecting to new host, client 32 creating new password for GeneMapper® IDX 31 creating user accounts 36 folder privileges client installation 28 resetting permissions 28 full installation computer requirements 6 DOS window 22 Ethernet requirements 6 installation time 6 log file 41 monitor requirements 6 troubleshooting 38, 41 D data options, instruments 9 destination folder, selecting 21, 25 DOS window client installation 25 during full installation 22 GeneMapper® ID-X Software v1.5 Installation Guide G GeneMapper® ID-X login 31 logout 35 genetic analyzer data options 9 instrument compatibility 9 H host computer name 18 I importing projects 36 installation problems, troubleshooting 41 63 Index installation time client installation 7 full installation on data collection computers 6 full installation on non-data collection computer 6 installer client 28 resetting permissions 28 specifying folder privileges 28 L limited product warranty 62 log file 41 login 31 logout 35 M minimum computer requirements software installation 8 System Properties dialog box 8 monitor requirements full installation 6 multi-user database obtaining host name 18 N NTFS permissions, setting manually 28 O R resetting folder permissions 28 S SDSs obtaining 62 software installation minimum computer requirements 8 T technical support checklist 54 contacting 62 needed information 54 training, information on 62 troubleshooting disabling firewall settings 38, 41 obtaining log file 41 technical support checklist 54 uninstalling software 38, 41 U user accounts connecting to new host 32 creating 36 multi-user database 32 W warranty 62 operating system requirements full installation 6 P password, creating for GeneMapper® ID-X 31 permissions, setting 28 product warranty 62 64 GeneMapper® ID-X Software v1.5 Installation Guide For support visit lifetechnologies.com/support or email [email protected] lifetechnologies.com 17 February March 2015
advertisement