Below you will find brief information for Hurricane Sliding Door H60 1175. The Hurricane Sliding Door H60 1175 is a Dade County approved hurricane sliding door system. It is designed to provide a secure and weather-tight barrier for your building. The door is easy to install and operate, and it features a variety of safety features to protect your occupants.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
▼
Scroll to page 2
of
43
Nabco Entrances Inc. S82 W18717 Gemini Drive PO Box 906 Muskego, WI 53150 Phone: 877-622-2694 Fax: 888-679-3319 www.nabcoentrances.com Automatic Entrance Systems Model 1175 (H60-Narrow) Hurricane Sliding Door System **Dade County Approved** WARNING ● Turn OFF all power to the Automatic Door if a Safety System is not working. ● Instruct the Owner to keep power turned OFF until corrective action can be achieved by a NABCO trained technician. Failure to follow these practices may result in serious consequences. ● NEVER leave a Door operating without all Safety detection systems operational. P/N 14-10275 December 30, 2014 Revision Installation Manual P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System Safety Practices WARNING: Do not install, operate or service this product unless you have read and understand the Safety Practices, Warnings, Installation and Operating Instructions contained in this manual. Failure to do so may result in property damage or personal injury. WARNING: Turn OFF all power to the Automatic Door if a Safety System is not working. Instruct the Owner to keep all power turned OFF until corrective action can be achieved by a NABCO trained technician. Failure to follow these practices may result in serious consequences NEVER leave a Door operating without all Safety detection systems operational. CAUTION: Read these safety practices before installing, operating or servicing the sliding door. Failure to follow these practices may result in serious consequences. Read, study and understand the operating instructions contained in or referenced in this manual before operating the sliding door. If you do not understand the instructions, ask the installing qualified technician to teach you how to use the sliding door. This manual and the owners’ manual must be given to and retained by the purchasing facility or end user. 1. If the door appears broken or does not seem to work correctly, it should be immediately removed from service and a qualified technician contacted for corrective action. 2. Disconnect power at the fused disconnect during all electrical or mechanical service. When uncertain whether power supply is disconnected, always verify using voltmeter. 3. All electrical troubleshooting or service must be performed by qualified electrical technicians and must comply with all applicable governing agency codes. 4. It is the responsibility of the installing door technician to install all warning and instructional labels in accordance with ANSI A156.10. 5. It is the responsibility of the purchasing facility or end user to keep warning instructional labels and literature legible, intact, and with the door. 6. Replacement labels and literature may be obtained from local NABCO Entrances, Inc. distributors. If the name of the local distributor is unknown, contact NABCO Entrances, Inc. at (877-622-2694) for assistance. 7. Do not place fingers or uninsulated tools inside the electrical control box. Touching wires or other parts inside the enclosure may cause electrical shock, serious injury or death. 2 877-622-2694 – www.nabcoentrances.com NABCO ENTRANCES INC. P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System Safety Practices 3 877-622-2694 – www.nabcoentrances.com NABCO ENTRANCES INC. P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System Contents A. B. C. D. E. F. G. H. I. J. K. L. M. N. O. P. Q. R. S. T. U. V. W. X. Rough Opening (RO) Preparation Framing and Header Assembly Installation of Track Glass Handling and Installation Installation of Swing Panel(s) Installation of Fixed Panel(s) Installation of Sliding Door(s) Adjusting of Door Adjusting Door Preload Adjustment of Interlocks Installation of Bottom Guide Adjusting Belt Tension Belt Alignment Installation of Bottom Sweep Vinyl Door Panic Adjustment and Verification of Breakout Magnet Installation Mounting of Accusensors Typical Slider Wiring Microprocessor Controller Holding Beams Electric Lock Electrical Information Troubleshooting Common Replacement Parts Wiring Diagrams Y. Return Policy Z. Appendix 4 5 6 7 8-9 10 11 12 13 14 15 15 16 16 17 18 19 19 19 19 20 21 22 23-28 29 30-42 TOOL LIST ½” Wrench: Box or Open End (2 required) 15/16” Open End Wrench 3/8” Drive Socket Wrench 7/16” Socket 6” Socket Extension Allen Wrenches 3/32”, 1/8”, 3/16” Phillips Screwdrivers: #2 and #3 Slotted Screwdriver: Large 4 Hand Drill: Electric or Cordless Drill: 1/8” 7/32” ¼” Masonry 3/8” by 82 Deg. Countersink Level: (Laser Type Preferred) Tape Measure Broom 877-622-2694 – www.nabcoentrances.com NABCO ENTRANCES INC. P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System A. Rough Opening (RO) Preparation 1. Check floor across entire opening. Make sure installation area is level and clear of debris. 2. RO height should be door height plus ¼” per side. (Allow for tile or other materials that may change floor height.) 3. RO width should be total door width plus ¼” per side. (See Figure 1) RO Width 90° 1/4" 90° RO Height 1/4" Finished Floor 1/4" Figure 1: Rough Opening Preparation 5 877-622-2694 – www.nabcoentrances.com NABCO ENTRANCES INC. P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System B. Framing and Header Installation 1. Place header on a flat surface with removable cover facing up. Protect the header from scratches. 2. Remove two screws from the bottom of the cover. Remove the cover. (See Figure 2) Remove parts box from header and set aside. 3. Position the jamb tubes on each end of the header. Fasten with the provided ¼-20 x 1 inch bolts into rivnuts in jambs. (See Figure 3) Refer to label on jamb for proper location. Back of Header Cover in Closed Position Cover Side of Header Swing Up Cover in Open Position Push In to Lock Rivnuts 1/4-20 Bolts (6 per side) Figure 2 Figure 3 Jamb Tube When not removing cover make sure that it is locked in securely! 1/4" Shim and plumb clearance CAUTION: When installing header, keep unprotected pedestrians out of the area below the header until it is secured to the building. Failure to do so may result in property damage or personal injury. 4. Lift header and jamb tubes into position. Jamb Tube Note: Unless it was a specially ordered unit, the cover on the fixed sidelite units with wall track is on the exterior. On a Full Open unit it is on the interior. 5. Level the header assembly by shimming under the appropriate jamb if necessary. 6. Plumb one jamb tube in both planes. If required, shim the back of the jamb. (See Figure 4) 7. When installing this unit it is important to be in compliance with Dade County Hurricane specifications for fastening the header and jambs to the building as specified on the prints in the Appendix. 8. Plumb and securely fasten the other jamb. 9. Reinstall cover. Install the Handi terminal bracket under the mounting bolt. (See Figure 5) It should 6 877-622-2694 – www.nabcoentrances.com Figure 4 Place Handy Terminal Bracket under this mounting bolt NABCO Nameplate Figure 5 NABCO ENTRANCES INC. P/N 14-10275 December 30, 2014 Revision 1. Snap a chalk line on the floor from jamb to jamb (See Figure 7) on the interior side of the building. Note the dimensions shown are for a Full Open. 2. Floor track is factory cut. Contact NABCO ENTRANCES customer service at (877) 622-2694 to order new track. 3. There will be two pieces of threshold for a Bi-Part and one piece of threshold for a Single. Both units will come with a Bolt Lock Plate that will be installed under the nose of the door panel(s). The Bi-Part configuration is shown in figure 8. 4. Locate track flush with the chalk line. Check floor track location with plumb bob from the header. It should be 1/8” inset from the header. (See Figure 9) 5. Prior to installation the floor track will need to be drilled in compliance with Dade County Hurricane specifications for fastening the threshold as specified on the prints in the Appendix. 6. Using the drilled floor track mark the location of the track holes onto the floor. Drill the holes using a 3/16-inch masonry bit. Fasten the track to the floor using ¼” x 2 ¾” ITW Buildex PFH Tapcons with a minimum of 1 ¾” embedment in 3500 psi concrete. Hurricane Slide Door System 6 1/2 Full open align with the pryout plug on the NABCO nameplate. C. Installation of Track (Full Open Units ONLY) Model 1175 (H60-Narrow) Finished floor Figure 6 Chalk line 1 3/4" 1 3/4" 4 1/2" 4 1/2" Jamb Tube 4 1/2" Floor Track Figure 7 Interior Bolt Lock Plate 2 filler strips 4 wear stripes Exterior SO width Clear opening SO width Figure 8 Header Cover side 4 1/2" Jamb Plumb line +1/8" to edge of track 1/8" 4 1/2" Track Full Open Figure 9 7 877-622-2694 – www.nabcoentrances.com NABCO ENTRANCES INC. P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System D. Glass Handling and Installation CAUTION: Use caution when moving and installing the glass panels. These panels are constructed with tempered glass. Any sharp objects that come in contact with the glass may cause the glass to craze. NABCO Entrances, Inc. is not responsible for broken glass. 1. When glazing the unit the use of a qualified glazer is required. 2. Be sure that the area surrounding the glass installation is free of debris and any sharp objects that could contaminate the glazing process or damage the glass. 3. The use of approved glazing materials is required. (See Figure 10) 1/8" Solutia Saflex III G Interlayer 3/16" Tempered Glass #10 x 2" @ 12" o.c. except near corner @ 3" o.c. Glass Stop Channel 142335 1" 3/16" Tempered Glass Dlubak Technologies Laminated/Tempered Glass (Typical) Reinforcement 3/4" x 3/4" x 1/8" Aluminum Angle Glass Stop Base 142336 #10 - 24 x PFH Thread Forming Staggered 2" From Each End 4-6" O.C. 1/2" Glass Bite Dow 995 Silicone (Typical) Typical Glazing Detail Entire Perimeter all Lites Figure 10 8 877-622-2694 – www.nabcoentrances.com NABCO ENTRANCES INC. P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System E. Installation of Swing Panel Jamb Tube 1. Locate the swing panel pivot in the parts box. 2. Install the pivot into the jamb by rotating it into the cutout in the jamb and fastening it with a 1/4'-20 x ¾ inch screw. (See Figure 11) 3. Drill thru the barrel of the pivot and into the track with a 7/32” bit. 4. Install the self-tapping ¼-20 x 1 inch screw down the barrel of the pivot and into the track. 5. Install the nylon guide into the barrel of the pivot. 6. Locate the swing panel. It will have the ball detent at the top and bottom of the nose stile. 7. (Full Open Units Only) Remove the control panel switch assembly from the panel. (See Figure 12) Save the screws for reinstallation. Optional key switches with the same functions are available from customer service. Descriptions of switch functions are described in Chart 1. Control Panel Switches Floor Track Figure 11 OFF ON NIGHT Control panel located in side panel on operator end of header AUTO ONE WAY HOLD OPEN FULL RED. OPEN Figure 12 Option Function Top 1. ON 2. Off 3. Night 1. Turns the unit on. 2. Turns the unit off. 3. Limits access to the door by turning off the sensors on the door but allowing the door to be accessed by a push plate, card reader or other source. Middle 1. One way 2. Auto 3. Hold Open 1. Sets the door to open in only one direction. (Entrance or Exit) 2. Sets the door to open in both directions. (Entrance and Exit) 3. Sets the door to open and remain open. Bottom 1. Full Open 2. Reduced Open 1. Sets the door to fully open. 2. Sets the door so that it does not open completely. 8. (Full Open Units Only) There are about 4 feet of cable inside the header for the control panel harness. Withdraw a sufficient amount of the harness to reach the control panel switches on the swing panel. 9. (Full Open Units Only) Route the control panel wiring harness from the header past the swing panel top pivot. (See Figures 13) 9 Swing Panel Pivot Panic Direction Pivot Pin Retracting Pin Control Panel Switch Harness From Header 877-622-2694 – www.nabcoentrances.com Figure 13 Sidelight Panel NABCO ENTRANCES INC. P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System Large Washer Use as required E. Installation of Swing Panel (Continued) 10. Position swing panel over bottom pivot. Note the panic direction and pivot location in Figure 13. 11. Retract the top pivot by pushing the pin down and aligning with the hole in the header. 12. Allow the pivot pin to snap into the hole. Make sure it fully engages the hole. If necessary, lift up on the retracting pin with a screwdriver. 13. (Full Open Unit Only) Pull the control panel wiring harness through the switch cutout in the stile. Connect the switch panel and reinstall with the screws retained earlier. 14. Assemble the limit arm. (See Figure 14) Rest the wheel of the limit arm inside the upper rail of the swing panel. Install the red-coated screw into the factory-drilled hole on the bottom of the header. Use one or two large washers as required. 15. Open and close the swing panel several times, while lifting on the flush bolt handle enough to make contact with the header and the floor track, to score both surfaces. (See Figure 15) 16. Locate the point where the score marks intersect the first centering groove on the bottom of the header (closest to the outside of the header) and the only groove on the floor track. Drill a 17/32” hole. (See Figure 16) Small Washer Spacer Red Coated Screw Figure 14 Flush Bolt Score Mark 17/32" Hole Door Top of Swing Panel Figure 15 Bottom of Swing Panel Door Flush Bolt Score Mark 17/32" Hole Figure 16 10 877-622-2694 – www.nabcoentrances.com NABCO ENTRANCES INC. P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System F. Installation of Fixed Panel (Fixed S/L units only.) Header 11 877-622-2694 – www.nabcoentrances.com Fixed Sidelite Sidelite Mounting Brackets Jamb Tube 1. Remove Control Panel Switch Assembly from the panel. (See Figure 12) Save screws for use during installation of the panel. 2. There is approximately four feet of cable secured inside the header for the control panel harness. Withdraw a sufficient amount of the harness to reach the control panel switches on the fixed panel. 3. Locate the fixed panel near the jamb tube. Route the control panel harness from the bottom of the header through the top of the rear stile and through the access cutout. 4. Connect the power down harness near the front edge of the panel to the 2 yellow wire harness from the header. Push the excess harness back into the header or hide it in the top rail of the sidelight. 5. Align the back end of the fixed panel with the brackets on the jamb tube. Ensure that no wires are pinched. (See Figure 17) 6. Position panel on to brackets and fasten with the provided screws. 7. Remove the bottom guide cavity cover from the bottom of the stile. Save the screws for use during the later steps of panel installation. 8. Install floor bracket into panel with the color coordinated ¼-20 x ½ inch screw. Plumb panel and mark holes on the floor. Drill holes with masonry bit and fasten the bracket to the floor. (See Figure 18) Figure 17 Figure 18 NABCO ENTRANCES INC. P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System G. Installation of Sliding Door(s) 4 3 10 Long belt clip used on bi-parts and all singles (SHORT ON UNITS WITH ELECTRIC LOCKS) Short belt used on bi-parts only (LONG WITH ELECTRIC LOCKS) 2 1 8 1. 2. 3. 4. 5. Jamb Tube Power Cut Off Switch Operator Control Belt Clip (Upper) 5 6 7 6. 7. 8. 9. 10. 9 Belt Clip (Lower) Roller Anti-riser Idler Handy Terminal Connector Figure 19 Anti-rise Track Hanger Roller Anti-riser 1. Loosen the hanger roller and anti-riser nuts with a 15/16-inch wrench. (See Figure 20) 2. Lift door onto track. Slightly tilting the door approach angle may be necessary to allow rollers to catch the track. (See Figure 21) 1/64" - 1/32" Clearance Note: If system is a Full Open unit, it will be necessary to pry up on the bottom guide on the back corner of the door to allow the door to enter the floor track. Figure 20 Position into track Anti-riser Track roller Lower panel CAUTION: Do not panic door until all adjustments are made and the doors are secured. Lift panel Figure 21 12 877-622-2694 – www.nabcoentrances.com NABCO ENTRANCES INC. P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System H. Adjustment of Door 1. Door height from finished floor is adjustable from 11/64 inch to 29/64 inch. (See Figure 22) 2. Place a 15/16-inch wrench on the nut of the roller. With another 15/16-inch open-end wrench, rotate the bolt clockwise to raise or lower the door. Note: Do not rotate the bolt counter clockwise, as this would unthread the bolt from the roller. 3. Still holding the bolt head, secure the nut against the door carrier. Repeat this process on the remaining rollers. 4. The leading edge of the doors should meet with no gap between the opposite door (or jamb tube in the case of a single unit) at the top or bottom. If necessary, adjust the height and angle of the doors according to Step 2. 5. Slide the anti-risers up in the slot until there is a 1/64-inch to 1/32-inch gap between anti-riser wheel and anti-riser track. Tighten the nut on the anti-rise wheel. 6. Attach belt clips(s) using the #12 x ¾ inch selfdrilling/self tapping screws. Starter mounting holes have been pre-drilled in the door carrier. The belt clips should be installed toward the leading edge of the doors. (See Figure 23) 7. Adjust the doorstop so there is a 3/8-inch gap from the face of the sidelight or swing panel. (See Figure 24) In some cases, the doorstop will be mounted on the jamb tube. 11/64" to 29/64" gap from floor No gaps, panels parallel Figure 22 Long belt clip used on bi-parts and all singles (SHORT ON UNITS WITH ELECTRIC LOCKS) Short belt used on bi-parts only (LONG WITH ELECTRIC LOCKS) Figure 23 3/8" Finger Protection Sidelight Panel Sliding Door Figure 24 13 877-622-2694 – www.nabcoentrances.com NABCO ENTRANCES INC. P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System Hanger I. Adjusting Door Preload (Glass must be installed before adjusting preload.) Pivot bar Preload adjust screw 1. Panic the door open to check door sag. (See Figure 25) 2. Loosen the two locking bolts on the block inside the top rail of the door. (See Figure 26) 3. Adjust door sag by rotating the setscrew on the back edge of the door with a 1/8-inch allen wrench. The door should latch without having to adjust the panel. A longer setscrew is provided in the parts box if required. 4. Retighten locking bolts. Door sag Preload adjust Pivot shaft Pivot block Figure 25 Do not allow the set screw to protrude more than an 1/8" past the end of stile Preload Block 5/16" adjusting set screw (if needed a 1/2" set screw is provided in parts box located in header carton) Locking Bolt Limit Arm Figure 26 14 877-622-2694 – www.nabcoentrances.com NABCO ENTRANCES INC. P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System J. Adjustment of Interlocks (Full Open and Pocketed) 1. Manually close the door(s). If the interlocks prevent the door(s) from closing, it will be necessary to move them outward and shim (See Figure 27) behind them. 2. Panic the door open to access the interlocks. 3. Loosen the mounting screws and slide the interlocks closer to the edges of the stile. Slide shims under the interlocks as needed to ensure proper engagement. (See Figure 28a & 28b) It may be necessary to remove some brush from the backside of the interlock with a pair of scissors. 4. When the interlock position is correct, drill a 1/8inch hole through the interlock and into the stile. Pound a roll pin from the parts box into each hole to lock the interlock in place. Figure 27 Shims Door Swing Figure 28a Shim 1/8" Drill Roll Pin Figure 28b 15 877-622-2694 – www.nabcoentrances.com NABCO ENTRANCES INC. P/N 14-10275 December 30, 2014 Revision K. Installation of Bottom Guide (Fixed Sidelight Only) Model 1175 (H60-Narrow) Hurricane Slide Door System Left Hand Bottom Guide Right Hand Bottom Guide 1. Locate the bottom guide assembly in the parts box. (See Figure 29) Note: There is a right hand and left hand bottom guide that will correspond to a right and left door. 2. Panic the door open. Attach the bottom guide, by using the two ¼-20 x 1 inch hex head bolts and two star washers, to the pivot stile. (See Figure 30) 3. Rotate the bottom guide, one roller at a time, into the cavity on the bottom of the fixed sidelight. Replace the bottom guide cavity cover removed in section F. Figure 29 L. Adjusting Belt Tension Note: Belt tension is factory set and should not require any adjustment except for unusual circumstances in header mounting or component adjustment. 1. Loosen the mounting nuts on the idler bracket. (See Figure 31) 2. Loosen the lock nut on the tension adjustment screw. Turn the tension adjustment screw to tighten or loosen the belt. The screw should push the idler bracket in the header. If the idler bracket does not move, loosen the two mounting nuts a few more turns. 3. Tension the belt so it is to approximately the same tension as received from the factory. It should not be so taut that it bends the drive or idler shafts! Tighten the lock nut on the adjustment screw against the bracket a secure the mounting nuts. 16 Figure 30 Lock nut Nut track Tension adjusting screw Screw clamp Belt tension is factory set and should not need adjustment 877-622-2694 – www.nabcoentrances.com DO NOT OVERTIGHTEN BELT Figure 31 NABCO ENTRANCES INC. P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System M. Belt Alignment Note: The alignment of the belt is factory-set. Flanges on the pulleys will compensate for minor misalignments and keep the belt on the pulleys. If the belt does come off the pulleys, the alignment of the shafts as well as other installed hardware should be checked. N. Installation of Bottom Sweep Vinyl 1. Slide the brush into the weathering extrusions. The excess vinyl should hang out the end of the holder at the rear of the door. 2. Locate the “L” shaped weathering on the outside of the door along the bottom edge with the vinyl located under the door. (See Figure 32) The edge of the extrusion should start just at the curve of the front edge of the door. Mark the three slots of the extrusion on the door. Drill three 1/8 inch mounting holes. 3. Mount the weathering on the door face using #6 x ½ inch self-tapping screws from parts box. 4. (Full Open Units Only) Locate the straight extrusions on the outside face of the swing panel. The shorter vinyl (1/4” tall) should be installed in the swing panel extrusion. There should not be any excess vinyl on this weathering. Mark the mounting holes and install the panel weathering in the same manner as the door weathering. 17 877-622-2694 – www.nabcoentrances.com SO SX Weathering Figure 32 NABCO ENTRANCES INC. P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System O. Door Panic Adjustment and Verification of Breakout Magnet Installation Note: The panic adjustment should be made after the glass is installed. The weight of the door with the glass will affect the amount of force required to panic the door open. If the force required to panic the door is not acceptable, it can be adjusted by performing the following steps. 1. Panic the door open. This may require a slight lifting force to the door or a slight hit with a rubber mallet to the top rail approximately three inches from the nose of the door. Protect the surface of the door to prevent damage. 2. Remove the panic block in the top of the door. (See Figure 33) 3. Loosen the setscrew on the front of the block. 4. Raise or lower the ball plunger with the screw on the underside of the block. Adjust the ball plunger for proper breakout resistance to meet ANSI A156.10 or local code. 5. Retighten the setscrew and reinstall into the door. Repeat if necessary. 6. On a full open unit the magnet is located inside the top rail of the swing panel. (See Figure 34) It should line up with the magnetic reed switch, is a 3/8” dia. black circle on the bottom of the header. 7. On fixed sidelights, the magnet is installed inside the top rail of the door. Place a steel washer on the interior side of the rail to confirm it is installed. The magnetic reed switch is installed about eye level in the leading stile of the sidelight facing towards the door. (See Figure 35) 1. LOOSEN SET SCREW 2. ADJUST BALL PLUNGER Figure 33 Magnet Figure 34 Figure 35 18 877-622-2694 – www.nabcoentrances.com NABCO ENTRANCES INC. P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System P. Mounting of Accusensors Note: Two identical Accusensors have been provided with your door package. (4 if the door opening is greater than 72 inches). The header was wired from the factory so that the activation circuitry on the exterior Accusensor is turned off in One Way Traffic Mode (the safety circuitry remains active and can not be turned off). The exterior Accusensor is located on the side of the header in the direction of panic or panel breakout. This can be easily reversed in the field by swapping the connectors where each Accusensor plugs into the main harness. 1. Locate the two individual Accusensors that were provided inside the header. The drilling template can be discarded. 2. Carefully pry off the cover of either Accusensor. Plug the connector from the header through the access hole in the Accusensor and into the connector on the Accusensor. 3. Use the screws provided inside the Accusensor (in the screw holes) to mount the Accusensor in the pre-drilled holes. (See Figure 36) 4. Re-install the cover and snap it into place. If it does not snap into place, the Accusensor has been mounted on to tightly. Back off on the mounting screws slightly and try again. If it is not properly secured, the cover may loosen due to vibration or wind gusts. 5. Repeat for the other Accusensor on the other side of the header. 6. To reverse the One Way Traffic Mode, locate the connectors mating the Accusensor Harnesses to the control box harness. They will be located under the plastic wire cover in the header. Swap the two connectors and re-secure the plastic wire cover. 19 877-622-2694 – www.nabcoentrances.com Activation & Safety Activation & Safety (Safety Only in One Way Traffic Mode) Panic Direction Figure 36 NABCO ENTRANCES INC. P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System Q. Typical Slider Wiring Wiring diagrams are included in the back of the manual, which reflect the typical primary and secondary circuits installed at the factory. The low voltage (12VDC) reed switch (panic breakaway) and Accusensor are easily connected on site using factory-installed connector housings. The factory uses Underwriters Laboratories’ (UL) Recognized Component wire, terminals and connector housings to manufacture the slider. Contact the Customer Service Department for assistance with special applications. R. Microprocessor Controller The Microprocessor Controller has been designed to control the numerous operating characteristics of the slide door system including speed, recycling, and door opening width. It will need to be programmed after the installation is complete. (See the Microprocessor Manual 159000 for more details). S. Holding Beams (optional) The holding beams are flush mounted in doorframes, facing each other. A pulsed, infrared light beam is continuously transmitted across the door opening. Interruption of the beam causes a relay switch closure. This signal will travel back to the microprocessor controller causing the doors to open and remain open until the object or person is out of the way. A wiring diagram is included in the back of this manual. T. Electric Lock (optional) Electric locks are available in two configurations: fail-safe and fail secure. These locks will prevent someone from opening the doors until an activation signal is applied to the electric lock. This signal could be from a remote switch, transmitter, or activation device on the face of the door. Fail-safe will allow the door to manually slide open if the power to the door unit is interrupted. Fail secure will not permit the door to be manually opened if power is interrupted. Fail secure cannot be opened until the power is restored and the lock receives an activation signal. Neither type of electric lock will inhibit the panic breakout. Each electric lock is factory installed and wired into the control box. (See Figure 37) The only adjustments required are minor horizontal alignments of the electric lock bolt with the trailing edge of the belt clip. Horizontal adjustment is made by moving the electric lock assembly along the nut track inside the header. With the door in the closed position, move the electric lock until the bolt comes in contact with the belt clip. The less door travel with the door in this position the better. Secure mounting and adjustment screws and re-check the bolt and door travel. It is also a good idea to check the rigidity of the transformer mounting. Shipping vibrations may have loosened the bracket. The transformer is integral to the lock assembly and requires 120 VAC power. A wiring diagram is included at the back of this manual for reference. Solenoid Pin Control Board Transformer Figure 37 20 877-622-2694 – www.nabcoentrances.com NABCO ENTRANCES INC. P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System U. Electrical Information CAUTION: Disconnect all power to the junction box prior to making any connections. 1. Convenient electric service holes have been provided in the slide header end caps and jamb tubes. An electrician should route 120 VAC, single phase, 5 amp (minimum) power to the factory supplied and mounted junction box in the header. 2. The electrician should connect one power hot lead (black) to the power cut off switch mounted inside the junction box. Utilizing an appropriate wire nut, the electrician should connect the common lead (white) to the loose common lead (white) found inside the junction box. The ground wire should be connected to the ground screw located in the bottom of the switch junction box. (See Figure 38) 3. Replace the junction box cover. The unit’s power should now be activated through the building’s electrical circuit breaker box. Proceed with performance set-up procedures outlined in the Microprocessor and Handy Terminal Manual (P/N 159000). 21 877-622-2694 – www.nabcoentrances.com Ground Screw Figure 38 NABCO ENTRANCES INC. P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System V. Troubleshooting Symptom Solution Accusensor does not seem to reach out far enough Accusensor is not seeing people accessing the door from the side. When the doors are panicked open, the system does not shut down. Doors do not move when power is applied or handy terminal connected. Increase the area lever on the side of the Accusensor to a higher number. Increase the opening speed on the door with the handy terminal. Turn on more of the area switches on the front of the Accusensor. The cover on the Accusensor will not snap on. Doors move very slowly when the handy terminal is connected. The doors do not open completely. I want to eliminate all outside switches and sensors and make the system operate in automatic mode. I want to reset the system back to the factory settings. Door does not run in “ON” but may run in “OFF” 22 Check the wiring of the power down switch in the fixed panel or bottom of header. Confirm the swing panel is closed completely. Check the power down magnet in the top rail of the swing panel is installed and aligned with the magnetic power down switch in the bottom of the header. To locate the problem circuit, disconnect the plugs at the Accusensor. The Microprocessor will ignore any switch or sensor when it is unplugged from circuit. Install a couple of thin washers to space the Accusensor off from the header and provide clearance for the cover. This is normal. It is “learning” the door stroke. After learning the stroke, the handy terminal will prompt you with options. Look for obstructions in the track as well as inside the header. Check to make sure that the belt clips are not hitting something. Check that the mode switch on the panel is not in “Reduced Opening” mode. Use the handy terminal and reinitialize the system. Disconnect the 12 pin connector from inside the microprocessor and install the special connector jumper tool p/n 115941 into its place. The system will consist of only the motor, operator and control box (Microprocessor). The handy terminal will be the only means of operating the door. 1. Plug in handy terminal and wait for door to close. 2. At “Swing/Slide Stroke?” enter YES 3. At “Swing Door Y or N?” enter YES (even though you have a slide door) 4. Door will try to initialize as a swing door and reset the settings. 5. It will prompt you with “Swing/Slide Stroke.” Enter YES 6. At “Swing Door Y or N?” enter NO 7. The system will now initialize as a slide door at the factory settings. 8. You must set the door stroke from the handy terminal from the prompts at this point. The holding beam connector (it has a red and white wire in it) in the main harness has a jumper plug connected to this plug. Remove the jumper. There have been cases where some installers have incorrectly connected this red/white connector to a blue wire connector. Remove the blue wire connector and install a jumper into it. The red/white should be empty and any open blue wire connectors should have a jumper installed. 877-622-2694 – www.nabcoentrances.com NABCO ENTRANCES INC. P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System W. Common Replacement Parts Motor alone 219206 EXIT NIGHT AUTO H.O. REDUCED FULL STOP Operator alone 219530 Motor & Operator assy 229528 GYRO TECH - 248901 Key Switches 219820 No. Handing Harness 119208 MICROPROCESSOR CONTROLLER POWER SOURCE (4P) NO. COLOR 1 2 WHITE 3 BLACK 4 HANDY TERMINAL (6P) SENSOR (12P) USE EMPTY 115VAC COMMON 115VAC HOT EMPTY OPERATOR (6P) NO. 1 2 3 4 5 6 COLOR RED ORANGE BROWN BLUE BLACK YELLOW USE MOTOR V PHASE ENCODER 12VDC ENCODER A PHASE MOTOR U PHASE ENCODER GND ENCODER B PHASE FUSE INSIDE RATING:125V, 4A SIZE:5.2 x 20mm WARNING For continued protection against fire, replace only with same type and rating of fuse. CAUTION 1.Please adjust this operator as per instruction manual. 2.Turn the power off, before opening the box. 3.Don't open this box except for replacing fuse. Otherwise, the warranty will be terminated. 4.Repair of this unit except by Lanson Industries, Inc. may cause software and hardware malfunction. NO. 1 2 3 4 SYMBOL 9DC12V 7 61 6B 5 H 6 7 8 9 10 11 12 M0 M1 62 SQ BA OUT + OUT - COLOR USE [SLIDER/SWINGER] BROWN 12VDC + RED 12VDC -,COMMON BLACK APPROACH WHITE THRESHOLD SENSING /PRESENCE SENSOR GREEN REDUCED OPENING /SAFETY MAT ORANGE MODE SW1 ORANGE MODE SW2 ORANGE APPROACH(THROUGH) YELLOW SEQUENTIAL BLUE BREAK OUT VIOLET OUTPUT + GRAY OUTPUT - GYRO TECH ENTRANCES LANSON INDUSTRIES INC. Microprocessor Control Box 248901 Door Roller Assembly 219034 Track Cap (for damaged track) 149463 Weather Strip 145592-01 Door Roller/Cover 248830 Anti-Rise Axle Assembly 219037 Bearing 240787 Left Hand Fixed Sidelight Bottom Guide 219046-20 Idler Assembly 229201 Pulley Only 119903 Full Open Bottom Guide 219053 Right Hand Roller & Bearing Only Fixed Sidelight Bottom Guide Full Open and Fixed Sidelight 149045 219046-10 Figure 39 23 877-622-2694 – www.nabcoentrances.com NABCO ENTRANCES INC. P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System X. Wiring diagram for connecting push plates or card readers for Night mode. Attach the normally open contacts across the red and black wire on either the rocker or key switches. Push buttom switch during night mode. EXIT NIGHT AUTO H.O. Red (#1) White (#6) Black (#2) Red White Black Green REDUCED FULL STOP Red (#8) Green (#1) Blue (#4) Blue White OFF NIGHT DOOR OPERATION ONLY ON Blue Red Blue ONE WAY AUTO Black Red Black White Red Blue Red White Green Black HOLD OPEN FULL Green Red Push buttom switch during night mode. REDUCED OPEN Figure 40 24 877-622-2694 – www.nabcoentrances.com NABCO ENTRANCES INC. P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System X. Wiring diagram Activation with Night Mode Closing contacts with door in NIGHT mode opens door. Blue Rocker Switch Connector Blue Black Red Orange M1 Orange MO Green Blue Breakaway Connectors White Red Green Blue 1175 Microprocessor Wire Diagram Activation with Night mode. Connect card reader and wall plate normally open dry contacts as shown. Access in the header. White Green Blue White Blue Green Figure 41 25 877-622-2694 – www.nabcoentrances.com NABCO ENTRANCES INC. 26 AUTO Black Rocker Switches REDUCED OPEN FULL Main Breaker Switch White Green Red White Red Blue Red Blue Black Green White Blue Red 877-622-2694 – www.nabcoentrances.com M.C. Handy Terminal Connector CN4 Grey White Black Exterior Accusensor Red Connector Brown Red Green Brown Red Blue Blue Blue Red White Green White Green White Green Breakaway Connectors Interior Accusensor Connector Red Holding Beam Connector White Blue Black Blue Rocker Switch Connector Black White Red Orange M1 Orange MO Green Blue NOTE: In some cases the interior and exterior Accusensors are reversed CN3 Purple Blue Yellow Orange 62 Orange M1 Brown Red Black White Green Orange MO Blue Green Red Rocker Switch Extension Harness 1175 Microprocessor Wire Diagram Motor Plug CN2 CN1 6 Ground OFF HOLD OPEN DOOR OPERATION ONLY 120 VAC Black Red Black ONE WAY NIGHT ON White P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System X. Microprocessor Wiring Diagram Figure 42 NABCO ENTRANCES INC. P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System X. Wiring Diagram for Fail Safe and Fail Secure Electric Locks RELAY(DC12V) GYRO TECH - 248901 No. MICROPROCESSOR CONTROLLER POWER SOURCE (4P) NO. COLOR 1 2 WHITE 3 BLACK 4 OPERATOR (6P) NO. 1 2 3 4 5 6 COLOR RED ORANGE BROWN BLUE BLACK YELLOW HANDY TERMINAL (6P) SENSOR (12P) USE EMPTY 115VAC COMMON 115VAC HOT EMPTY USE MOTOR V PHASE ENCODER 12VDC ENCODER A PHASE MOTOR U PHASE ENCODER GND ENCODER B PHASE FUSE INSIDE RATING:125V, 4A SIZE:5.2 x 20mm WARNING For continued protection against fire, replace only with same type and rating of fuse. CAUTION 1.Please adjust this operator as per instruction manual. 2.Turn the power off, before opening the box. 3.Don't open this box except for replacing fuse. Otherwise, the warranty will be terminated. 4.Repair of this unit except by Lanson Industries, Inc. may cause software and hardware malfunction. NO. 1 2 3 4 SYMBOL 9DC12V 7 61 6B 5 H 6 7 8 9 10 11 12 M0 M1 62 SQ BA OUT + OUT - 9DC12V (BROWN) 123456789 COLOR USE [SLIDER/SWINGER] BROWN 12VDC + RED 12VDC -,COMMON BLACK APPROACH WHITE THRESHOLD SENSING /PRESENCE SENSOR GREEN REDUCED OPENING /SAFETY MAT ORANGE MODE SW1 ORANGE MODE SW2 ORANGE APPROACH(THROUGH) YELLOW SEQUENTIAL BLUE BREAK OUT VIOLET OUTPUT + GRAY OUTPUT - OUT+ (VIOLET) OUT- (GRAY) 7 (RED) ENTRANCES LANSON INDUSTRIES INC. Green Incoming AC115V TRANSFORMER Black ACTIVATE ON SIGNAL OUTPUT LOCKED UNLOCKED (ON) SIGNAL CLOSED OPEN >>> CLOSE DOOR ELECTRIC LOCK / STRIKE Solenoid Yellow ~ Orange + - AC24V White time delay(0.25~1sec) BlackFail Secure Type Fail Safe Type Black GYRO TECH ~ RECTIFIER Orange NOTE: LOCK ONLY WORKS IN: OFF ONE WAY & NIGHT MODES ONLY LOCKED CLOSED time delay(0.25~1sec) andy Terminal : Aux. Output [0] , time delay [0]~[3] Mode Input : One Way Traffic Mode or Night Mode Generic Wiring Diagram for Fail Safe and Fail Secure Electric Locks Figure 43 27 877-622-2694 – www.nabcoentrances.com NABCO ENTRANCES INC. P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System X. Holding Beam Wiring Diagram Telco Brand Safety Beams Wiring Diagram for Holding Beams for Breakout Shutdown WHITE GREEN GREEN WIRE NUT BROWN ORANGE BROWN BLACK BROWN BROWN RED BLUE BLUE BLUE BROWN RED RED RED RECEIVER TRANSMITTER SMR 3106S SMT 3000S BLACK LIGHT BLUE BLACK GREY GREY YELLOW WHITE GREEN BLUE BLACK "REDUCE" LEAVE OPEN BLUE GREY GREY YELLOW WHITE GREEN BLACK ACUSENSOR HARNESS PT. NO. 219246 INTERIOR ACUSENSOR PT. NO. 148902 Telco Brand Safety Beams EXTERIOR ACUSENSOR WHITE PT. NO. 148902 GREEN MAGNETIC POWER DOWN SWITCH HOLD BEAM PIGTAIL PT. NO. 229222 PT. NO. 1110188 WHITE GREEN Wiring Diagram for Holding Beams as a Safety WHITE GREEN GREEN BROWN ORANGE BROWN BLACK BROWN RED BLUE BLUE BROWN BROWN BLUE RECEIVER TRANSMITTER SMR 3106S SMT 3000S RED RED RED BLACK BLACK "REDUCE" LEAVE OPEN LIGHT BLUE BROWN GREY GREY WHITE YELLOW GREEN PLUG WITH BLUE JUMPER (MUST BE IN PLACE) BLUE WHITE BLACK GREEN BLACK ACUSENSOR HARNESS PT. NO. 219246 ACUSENSOR HARNESS PT. NO. 219246 MAGNETIC POWER DOWN SWITCH PT. NO. 229222 BLACK RECEIVER TRANSMITTER SMR 3106S SMT 3000S LIGHT BLUE BLACK "REDUCE" LEAVE OPEN BLUE EXTERIOR ACUSENSOR WHITE PT. NO. 148902 GREEN MAGNETIC POWER DOWN SWITCH PT. NO. 229222 HOLD BEAM PIGTAIL PT. NO. 1110188 WHITE GREEN BROWN GREY GREY YELLOW Telco Brand Safety Beams INTERIOR ACUSENSOR PT. NO. 148902 Holding Beam Wire Diagram P/N 1510194 March 28, 2001 Figure 44 28 877-622-2694 – www.nabcoentrances.com NABCO ENTRANCES INC. P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System X. Accusensor Wire Path Diagram Acusensor 2's MUST use 12 VDC (not 24v) Brown Gray Red 1 2 3 4 Yellow Yellow 1 2 3 4 Gray 24 VAC Yellow COM Yellow N.O. AREA SWITCH ON ON ON ON ACUSENSOR AC / DC 12 ~ 24V OUTPUT ON OFF mode A mode C mode B mode D ENTRANCES AREA LEVER ON CONNECTION GRAY GRAY YELLOW YELLOW GYRO TECH MODE SWITCH INSP. O.K. No. OFF 30 sec. 15 sec. SENS. [High] SENS. [Low] 5 min. 90 sec. 1 2 3 4 5 Red 4 3 2 1 Yellow 4 3 2 1 Yellow Red Brown Green Orange Brown or Red 4 3 2 1 Extension Harness Exterior Sensor Black Interior Sensor Brown Main Harness Mode Input for SW1 and SW2 SW1 SW2 Off Off Off On On On On Off Results Auto Mode. Approach and Approach Thru signals available Electric Lock is always unlocked Night Mode. None of the activation signals will be accepted. Sensors provide threshold safety and Electric Lock is always locked. Full Open Mode. The door keeps the full open point, not affected by sensors. Electric Lock is always unlocked One Way Traffic. The interior sensor activates the door, the exterior sensor provides threshold safety. Electric Lock is locked until an interior activation is received. MODE SWITCH TABLE MO M1 Mode Open Open Auto Gnd Open Exit Gnd Gnd Hold Open Open Gnd Night Figure 45 29 877-622-2694 – www.nabcoentrances.com NABCO ENTRANCES INC. P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System Y. NABCO ENTRANCES RETURN POLICY If it is necessary to return a malfunctioning unit to NABCO, please use the following guidelines: Return Material Tags (RMT) are to be used for in and out of warranty materials. The RMT is also used for repair and return as well as return for credit transactions. An RMT must accompany all returned items. Complete one RMT for each item that will be returned. The following information should be recorded on the tag: • • • • • • • • • Serial No. or Part No. – Serial numbers for electronic components are stamped, engraved or printed on stickers and located on the component. Non-electrical parts usually do not have serial numbers. Part name. Expiration Date – Expiration dates for electronic components are stamped, engraved or printed on stickers and located on the component. Non-electrical parts usually do not have expiration dates. For “warranty claims of non-electrical parts”, please include a photocopy of the original NABCO invoice the part was purchased on. Date Returned – the date that the part is returned to NABCO Entrances Inc. Requested Repair and Return Action – Specify in/out warranty for R&R, Exchange, or in warranty for credit. For requests for credits, please write the number of the invoice you want credited. Firm Name Date of Installation Installed at Job Describe Part Problem The RMT tag is printed in triplicate. Please keep the top copy of the tag for your returns. Send the remaining two copies along with the part to the attention of the Repair and Return Department at NABCO Entrances Inc. Please remember to package the parts properly. Ship the parts freight prepaid. Collect shipments will be refused. If inquiring on the returned part, please use the RMT number associated with that part. NABCO Entrances Standard Terms & Conditions and Warranty govern all returned items. These are provided in detail in the Terms and Conditions section of the NABCO Entrances Price Book. If you have any questions on warranty or the use of the RMT tags, please call NABCO’s Customer Service Department toll free at 1-877NABCO WI (1-877-622-2694). 30 877-622-2694 – www.nabcoentrances.com NABCO ENTRANCES INC. P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System Z. Appendix 31 A1. A2. A3. A4. A5. A6. Full Open – Concrete Building Frame Pg. 1 of 6 Full Open – Concrete Building Frame Pg. 2 of 6 Full Open – Steel Building Frame Pg. 3 of 6 Full Open – Steel Building Frame Pg. 4 of 6 Full Open – Aluminum Building Frame Pg. 5 of 6 Full Open – Aluminum Building Frame Pg. 6 of 6 A7. A8. A9. A10. A11. A12. Fixed Sidelite – Concrete Building Frame Pg. 1 of 6 Fixed Sidelite – Concrete Building Frame Pg. 2 of 6 Fixed Sidelite – Steel Building Frame Pg. 3 of 6 Fixed Sidelite – Steel Building Frame Pg. 4 of 6 Fixed Sidelite – Aluminum Building Frame Pg. 5 of 6 Fixed Sidelite – Aluminum Building Frame Pg. 6 of 6 877-622-2694 – www.nabcoentrances.com NABCO ENTRANCES INC. 2" Typ 3" Typ 6" Typ Bottom Rail Top Rail 4" Typ 4" Typ SX 3500 PSI Concrete 3500 PSI Concrete 3500 PSI Concrete Threshold Header Jambs Design Pressure Rating Substrate EXTERIOR ELEVATION SX ACCESS COVER (INTERIOR) SIDE "Y" Header 3" Typ Bottom Rail 35" Top Rail Location SO "X" Bottom Rail 42 13/16" Max D/O 70 1/2" Max D/O Top Rail 2" Typ "Y" SO 1/8" Solutia Saflex III G Interlayer 1" (Typical) 1/2" Glass Bite 3/16" Tempered Glass #10 x 2" @ 12" o.c. except near corner @ 3" o.c. Glass Stop Channel 142335 A1 Lock Reinforcement Plate 1 1/2" x 15" x .105" (12 Ga) Door Sweep Exterior Mounting Screws (Pairs) 3 1/4" 1 3/4" Interior R/H Carrier 6 1/2" 1/4" Tie Rods 3/8" x 45 15/16" Max 1/2" REVISIONS 3 Updated Drawing 2 Updated Floor Track 1 REVISED 0 INITIAL ISSUE REV DESCRIPTION 29May01 07Feb.00 01JUL98 01APR97 DATE Threshold Tie Rods Torque Pressure Is 15-20 Ft. Lbs. Interior 1 3/4" 1 1/2" Header 1/4" Max Shim Space DRAWING NUMBER: 1175-04C Page 1 of 6 CONCRETE BUILDING FRAME CONSTRUCTION STANDARD ELEVATIONS & SECTIONS SYSTEM GT1175 BIPART SLIDER - FULL OPEN Concrete Construction 2 Exterior SECTION "X-X" Threshold Ramp (Both Sides) 1/2" 6 1/2" 3 1/2" L/H Carrier Weathering Pile (Schelegel Polybond) Cover 1/4" Max Shim Space S82 W18717 GEMINI DRIVE P.O. BOX 906 MUSKEGO, WISCONSIN 53150 TOLL FREE PHONE: 1-877-622-2694 FAX: (262) 679-2505 SECTION "Y-Y" Mounting Screws Pairs Sidelight Sweep Dlubak Technologies Laminated/Tempered Glass (Typical) Reinforcement 3/4" x 3/4" x 1/8" Aluminum Angle Glass Stop Base 142336 #10 - 24 x PFH Thread Forming Staggered 2" From Each End 4-6" O.C. 3/16" Tempered Glass Typical Glazing Detail Entire Perimeter all Lites Adams Rite #1853A/505 Maximum Security Lock Extending Into Header and Threshold (See Page 2) Dow 995 Silicone "Z" 12" Typ 4" Typ 4 Typ 6" Typ 6" Typ 6" Typ 6" Typ 3" Typ Bottom Rail Top Rail 4" Typ 2" Typ WHERE WATER INFILTRATION WHERE WATER INFILTRATION REQUIREMENT IS NEEDED REQUIREMENT IS NOT NEEDED Positive NOT APPROVED +60 PSF Negative NOT APPROVED -70 PSF 4 Typ 9 3/4" Typ 12" Typ 91 1/2" Max "Z" 12" Typ 9 3/4" Typ "X" 70 1/4" Max D/O 4" Typ 1" 6'-11" DOOR OPENING HEIGHT 3 1/2" 7 1/2" 7'-0" Door Pivot (See Page 2) 1 1/2" 7'-7 1/2" FRAME HEIGHT Kawneer Flush Bolt (Typical) (See Page 2) 6 1/2" 70 1/2" Max D/O All Anchors are in Pairs 192" Max 4" 4" 1 1/4" 877-622-2694 – www.nabcoentrances.com 4" 32 1" Reference Fastener Chart for Anchors P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System NABCO ENTRANCES INC. 33 877-622-2694 – www.nabcoentrances.com 4'-0" 5'-0" 6'-0" 7'-0" TYPE 2 1/8" 14 1/8" Typ 14 1/8" Typ 5/8" Typ Rod Engagement 3/16" Panel Stile 1.0" 3" 1.75" Typ Pivot Rod 1.0" Dia. 2 1/8" Pivot Stile 3.5" Top Rail A2 Typical Door Pivot Pre-Load Block "B" (DOOR OPENING) "A" 2 1/8" 2 1/8" (2) 1/4 - 20 x 1 3/4" Hex Head Capscrew Gr. 5 (2) 3/8 - 16 x 1 1/2" Holocrome Low Head Socket Capscrew SECTION "Z-Z" Carrier 2.06" 4.0" Carrier Bar Weldment Door Stiles Weathering Pile (Amesbury - Center Fin) Panel Stile "D" "E" "C" "D" "E" "G" "F" Panel Stile Jambs REVISIONS Updated Drawing Updated Floor Track 1 REVISED 0 INITIAL ISSUE REV DESCRIPTION 3 2 29May01 07Feb.00 01JUL98 01APR97 DATE Composition Manufacturer William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. DRAWING NUMBER: 1175-04C Page 2 of 6 CONCRETE BUILDING FRAME CONSTRUCTION STANDARD ELEVATIONS & SECTIONS SYSTEM GT1175 BIPART SLIDER - FULL OPEN Concrete Construction 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6005 - T5 aluminum 6005 - T5 aluminum 6061 - T6 aluminum 6063 - T5 aluminum 6063 - T5 aluminum 6063 - T5 aluminum S82 W18717 GEMINI DRIVE P.O. BOX 906 MUSKEGO, WISCONSIN 53150 TOLL FREE PHONE: 1-877-622-2694 FAX: (262) 679-2505 249009 249010 249011 149014 149088 149359 149085 149086 148922 149016 149017 145840 242497 142336 142335 NABCO Part No. Material List Use (7) 1/4" x 3 3/4" ITW Buildex PFH Tapcons in pairs at 12" o.c. starting 9 3/4" from each corner, total of (14) Tapcons Header (Ext.) Roller Track (Ext.) Cover (Ext.) Door Carrier (Ext.) Top Rail - Sidelite (Ext.) Top Rail - Door (Ext.) Bottom Rail - All (Ext.) Pivot Stile (Ext.) Stile (Ext.) Threshold (Ext.) Floor Track Ramp (Ext.) Angle (Ext.) Jamb (Ext.) Glass Stop Base (Ext.) Glass Stop Channel (Ext.) Description 3500 PSI Concrete use (4) 1/4" x 2 3/4" ITW Buildex PFH Tapcons with minimun 1 3/4" embedment in 3500 psi concrete at each sash corner, a total of (28) in all at header 3500 PSI Concrete Header Mounting Screws (Pairs) use (6) 1/4" x 2 3/4" ITW Buildex PFH Tapcons with minimun 1 3/4" embedment in 3500 psi concrete at each sash corner, a total of (48) in all at threshold 3/16" 3500 PSI Concrete 2 1/8" Weathering Pile (Schelegel Polybond) 1/4" Max Shim Space Threshold Fastener Type, Spacing and Quantity Fastener Chart Panel Stile Weathering Strip 1 3/4" Substrate 3" 2 1/8" 2 1/8" Door Stile Pivot Rod Jamb Tube 4 1/2" x 1 3/4" x 1/8" Location Exterior Interior DIMENSION DIMENSION DIMENSION DIMENSION "D" DIMENSION DIMENSION DIMENSION "G" OPENING DIMENSION "A" "B" "C" (Door Panel Width) "E" "F" Daylight Opening Incl. 1/4" shim each side 48" 54" 10'-0" 29 1/4" 23" 31 1/16" 24 13/16" 10' 1/2" 60" 66" 12'-0" 35 1/4" 29" 37 1/16" 30 13/16" 12' 1/2" 72" 78" 14'-0" 41 1/4" 35" 43 1/16" 36 13/16" 14' 1/2" 84" 90" 16'-0" 47 1/4" 41" 49 1/16" 42 13/16" 16' 1/2" "G" "F" 2 1/8" Kawneer #37227 Door Stile Pivot Rod Weathering Strip Flush Bolt & Lock Rod Detail 35.0" 1/4" Max Shim Space 3/4" 4 1/2" 3" Mounting Screws (Pairs) 1 3/4" Jamb Tube 4 1/2" x 1 3/4" x 1/8" P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System NABCO ENTRANCES INC. 3" Typ 6" Typ Bottom Rail Top Rail SX 3500 PSI Concrete Min. 1/8" thick steel Min. 1/8" thick steel Threshold Header Jambs Design Pressure Rating Substrate EXTERIOR ELEVATION SX ACCESS COVER (INTERIOR) SIDE "Y" Header 3" Typ Bottom Rail 35" Top Rail Location SO "X" Bottom Rail 42 13/16" Max D/O 70 1/2" Max D/O Top Rail 6" Typ 6" Typ 4" Typ 6" Typ SO 1" (Typical) 1/2" Glass Bite 1/8" Solutia Saflex III G Interlayer 3/16" Tempered Glass #10 x 2" @ 12" o.c. except near corner @ 3" o.c. Glass Stop Channel 142335 A3 Lock Reinforcement Plate 1 1/2" x 15" x .105" (12 Ga) Door Sweep Exterior Mounting Screws (Pairs) 3 1/4" 1 3/4" Interior R/H Carrier 6 1/2" 1/4" Tie Rods 3/8" x 45 15/16" Max 1/2" REVISIONS 3 Updated Drawing 2 Updated Floor Track 1 REVISED 0 INITIAL ISSUE REV DESCRIPTION 29May01 07Feb.00 01JUL98 01APR97 DATE Threshold Tie Rods Torque Pressure Is 15-20 Ft. Lbs. Interior 1 3/4" 1 1/2" Header 1/4" Max Shim Space DRAWING NUMBER: 1175-04S Page 3 of 6 STEEL BUILDING FRAME CONSTRUCTION STANDARD ELEVATIONS & SECTIONS SYSTEM GT1175 BIPART SLIDER - FULL OPEN Steel Construction 2 Exterior SECTION "X-X" Threshold Ramp (Both Sides) 1/2" 6 1/2" 3 1/2" L/H Carrier Weathering Pile (Schelegel Polybond) Cover 1/4" Max Shim Space S82 W18717 GEMINI DRIVE P.O. BOX 906 MUSKEGO, WISCONSIN 53150 TOLL FREE PHONE: 1-877-622-2694 FAX: (262) 679-2505 SECTION "Y-Y" Mounting Screws Pairs Sidelight Sweep Dlubak Technologies Laminated/Tempered Glass (Typical) Reinforcement 3/4" x 3/4" x 1/8" Aluminum Angle Glass Stop Base 142336 #10 - 24 x PFH Thread Forming Staggered 2" From Each End 4-6" O.C. 3/16" Tempered Glass Typical Glazing Detail Entire Perimeter all Lites Adams Rite #1853A/505 Maximum Security Lock Extending Into Header and Threshold (See Page 2) Dow 995 Silicone "Z" 12" Typ 4" Typ 6" Typ 4 Typ 6" Typ 6" Typ 6" Typ 6" Typ 3" Typ Bottom Rail Top Rail 4" WHERE WATER INFILTRATION WHERE WATER INFILTRATION REQUIREMENT IS NEEDED REQUIREMENT IS NOT NEEDED Positive NOT APPROVED +60 PSF Negative NOT APPROVED -70 PSF 4 Typ 9 3/4" Typ 12" Typ 91 1/2" Max "Z" 12" Typ 9 3/4" Typ 4" Typ "Y" 70 1/4" Max D/O "X" 3 1/2" 7 1/2" 7'-0" 4" 1 1/2" 1" 6'-11" DOOR OPENING HEIGHT Door Pivot (See Page 2) 7'-7 1/2" FRAME HEIGHT All Anchors are in Pairs 192" Max 6 1/2" 70 1/2" Max D/O Kawneer Flush Bolt (Typical) (See Page 2) 4" 4" 1 1/4" 877-622-2694 – www.nabcoentrances.com 4" 34 1" Reference Fastener Chart for Anchors P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System NABCO ENTRANCES INC. 35 877-622-2694 – www.nabcoentrances.com 4'-0" 5'-0" 6'-0" 7'-0" TYPE 2 1/8" 14 1/8" Typ 14 1/8" Typ 5/8" Typ Rod Engagement 3/16" Panel Stile 1.0" 3" 1.75" Typ Pivot Rod 1.0" Dia. 2 1/8" Pivot Stile 3.5" Top Rail A4 Typical Door Pivot Pre-Load Block "B" (DOOR OPENING) "A" 2 1/8" 2 1/8" (2) 1/4 - 20 x 1 3/4" Hex Head Capscrew Gr. 5 (2) 3/8 - 16 x 1 1/2" Holocrome Low Head Socket Capscrew SECTION "Z-Z" Carrier 2.06" 4.0" Carrier Bar Weldment Door Stiles Weathering Pile (Amesbury - Center Fin) Panel Stile "D" "E" "C" "D" "E" Min. 1/8" thick steel Min. 1/8" thick steel Header Jambs 2 29May01 07Feb.00 01JUL98 01APR97 DATE "G" "F" Panel Stile Fastener Type, Spacing and Quantity Fastener Chart Panel Stile Weathering Strip Door Stile Pivot Rod Jamb Tube 4 1/2" x 1 3/4" x 1/8" 2 1/8" 1 3/4" 3/16" Mounting Screws (Pairs) Weathering Pile (Schelegel Polybond) 1/4" Max Shim Space Composition Manufacturer William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. DRAWING NUMBER: 1175-04S Page 4 of 6 STEEL BUILDING FRAME CONSTRUCTION STANDARD ELEVATIONS & SECTIONS SYSTEM GT1175 BIPART SLIDER - FULL OPEN Steel Construction 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6005 - T5 aluminum 6005 - T5 aluminum 6061 - T6 aluminum 6063 - T5 aluminum 6063 - T5 aluminum 6063 - T5 aluminum S82 W18717 GEMINI DRIVE P.O. BOX 906 MUSKEGO, WISCONSIN 53150 TOLL FREE PHONE: 1-877-622-2694 FAX: (262) 679-2505 249009 249010 249011 149014 149088 149359 149085 149086 148922 149016 149017 145840 242497 142336 142335 NABCO Part No. Material List Use (7) 1/4" x 3 1/4" Zinc Tek (Broward bolt) pairs at 12" o.c. starting 9 3/4" from each corner, total of (14) anchors use (4) 1/4 - 14 x 1 1/4" Hilti HWH self drilling screws with minimum 1" embedment in steel at each sash corner, a total of (32) in all at header use (6) 1/4" x 2 3/4" ITW Buildex PFH Tapcons with minimun 1 3/4" embedment in 3500 psi concrete at each sash corner, a total of (48) in all at threshold 2 1/8" 2 1/8" Header (Ext.) Roller Track (Ext.) Cover (Ext.) Door Carrier (Ext.) Top Rail - Sidelite (Ext.) Top Rail - Door (Ext.) Bottom Rail - All (Ext.) Pivot Stile (Ext.) Stile (Ext.) Threshold (Ext.) Floor Track Ramp (Ext.) Angle (Ext.) Jamb (Ext.) Glass Stop Base (Ext.) Glass Stop Channel (Ext.) REVISIONS Updated Drawing Updated Floor Track 1 REVISED 0 INITIAL ISSUE REV DESCRIPTION 3 3500 PSI Concrete Description Substrate Location 3" Threshold Exterior Interior DIMENSION DIMENSION DIMENSION DIMENSION "D" DIMENSION DIMENSION DIMENSION "G" OPENING DIMENSION "A" "B" "C" (Door Panel Width) "E" "F" Daylight Opening Incl. 1/4" shim each side 48" 54" 10'-0" 29 1/4" 23" 31 1/16" 24 13/16" 10' 1/2" 60" 66" 12'-0" 35 1/4" 29" 37 1/16" 30 13/16" 12' 1/2" 72" 78" 14'-0" 41 1/4" 35" 43 1/16" 36 13/16" 14' 1/2" 84" 90" 16'-0" 47 1/4" 41" 49 1/16" 42 13/16" 16' 1/2" "G" "F" 2 1/8" Kawneer #37227 Door Stile Pivot Rod Weathering Strip Flush Bolt & Lock Rod Detail 35.0" 1/4" Max Shim Space 3/4" 4 1/2" 3" Mounting Screws (Pairs) 1 3/4" Jamb Tube 4 1/2" x 1 3/4" x 1/8" P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System NABCO ENTRANCES INC. Positive Negative 3" Typ 6" Typ Bottom Rail Top Rail SX Min 1/8" thick 6063-T5 Aluminum Min 1/8" thick 6063-T5 Aluminum Header Jamb Design Pressure Rating Substrate 3500 PSI Concrete Location EXTERIOR ELEVATION SX ACCESS COVER (INTERIOR) SIDE "Y" Header 3" Typ Bottom Rail 35" Top Rail 6" Typ 4" Typ 6" Typ Threshold SO "X" Bottom Rail 42 13/16" Max D/O 70 1/2" Max D/O Top Rail "Y" SO 1/8" Solutia Saflex III G Interlayer 1" (Typical) 1/2" Glass Bite 3/16" Tempered Glass #10 x 2" @ 12" o.c. except near corner @ 3" o.c. Glass Stop Channel 142335 A5 Lock Reinforcement Plate 1 1/2" x 15" x .105" (12 Ga) Door Sweep Exterior Mounting Screws (Pairs) 2 REVISIONS Updated Drawing Updated Floor Track 1 REVISED 0 INITIAL ISSUE REV DESCRIPTION 3 3 1/4" 1 3/4" Interior R/H Carrier 6 1/2" 1/4" Tie Rods 3/8" x 45 15/16" Max 1/2" 29May01 07Feb.00 01JUL98 01APR97 DATE Threshold Tie Rods Torque Pressure Is 15-20 Ft. Lbs. Interior 1 3/4" 1 1/2" Header 1/4" Max Shim Space DRAWING NUMBER: 1175-04A Page 5 of 6 ALUMINUM BUILDING FRAME CONSTRUCTION STANDARD ELEVATIONS & SECTIONS SYSTEM GT1175 BIPART SLIDER - FULL OPEN Aluminum Construction 2 Exterior SECTION "X-X" Threshold Ramp (Both Sides) 1/2" 6 1/2" 3 1/2" L/H Carrier Weathering Pile (Schelegel Polybond) Cover 1/4" Max Shim Space S82 W18717 GEMINI DRIVE P.O. BOX 906 MUSKEGO, WISCONSIN 53150 TOLL FREE PHONE: 1-877-622-2694 FAX: (262) 679-2505 SECTION "Y-Y" Mounting Screws Pairs Sidelight Sweep Dlubak Technologies Laminated/Tempered Glass (Typical) Reinforcement 3/4" x 3/4" x 1/8" Aluminum Angle Glass Stop Base 142336 #10 - 24 x PFH Thread Forming Staggered 2" From Each End 4-6" O.C. 3/16" Tempered Glass Typical Glazing Detail Entire Perimeter all Lites Adams Rite #1853A/505 Maximum Security Lock Extending Into Header and Threshold (See Page 2) Dow 995 Silicone "Z" 12" Typ 4" Typ 6" Typ 4 Typ 6" Typ 6" Typ 6" Typ 6" Typ 3" Typ Bottom Rail Top Rail 4" Typ 6" Typ WHERE WATER INFILTRATION WHERE WATER INFILTRATION REQUIREMENT IS NEEDED REQUIREMENT IS NOT NEEDED +60 PSF NOT APPROVED -70 PSF NOT APPROVED 4 Typ 9 3/4" Typ 12" Typ 91 1/2" Max "Z" 12" Typ 9 3/4" Typ 4" Typ "X" 70 1/4" Max D/O Door Pivot (See Page 2) 3 1/2" 1" 6'-11" DOOR OPENING HEIGHT 4" Typ 1 1/2" 7 1/2" 7'-0" 7'-7 1/2" FRAME HEIGHT Kawneer Flush Bolt (Typical) (See Page 2) 6 1/2" 70 1/2" Max D/O All Anchors are in Pairs 192" Max 4" 4" 1 1/4" 877-622-2694 – www.nabcoentrances.com 4" 36 1" Reference Fastener Chart for Anchors P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System NABCO ENTRANCES INC. 37 877-622-2694 – www.nabcoentrances.com 4'-0" 5'-0" 6'-0" 7'-0" TYPE 2 1/8" 14 1/8" Typ 14 1/8" Typ 5/8" Typ Rod Engagement 3/16" Panel Stile 1.0" 3" 1.75" Typ Pivot Rod 1.0" Dia. 2 1/8" Pivot Stile 3.5" Top Rail A6 Typical Door Pivot Pre-Load Block "B" (DOOR OPENING) "A" 2 1/8" 2 1/8" (2) 1/4 - 20 x 1 3/4" Hex Head Capscrew Gr. 5 (2) 3/8 - 16 x 1 1/2" Holocrome Low Head Socket Capscrew SECTION "Z-Z" Carrier 2.06" 4.0" Carrier Bar Weldment Door Stiles Weathering Pile (Amesbury - Center Fin) Panel Stile "D" "E" "C" "D" "E" "G" "F" Jamb REVISIONS Updated Drawing Updated Floor Track 1 REVISED 0 INITIAL ISSUE REV DESCRIPTION 3 2 29May01 07Feb.00 01JUL98 01APR97 DATE Composition Manufacturer William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. DRAWING NUMBER: 1175-04A Page 6 of 6 ALUMINUM BUILDING FRAME CONSTRUCTION STANDARD ELEVATIONS & SECTIONS SYSTEM GT1175 BIPART SLIDER - FULL OPEN Aluminum Construction 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6005 - T5 aluminum 6005 - T5 aluminum 6061 - T6 aluminum 6063 - T5 aluminum 6063 - T5 aluminum 6063 - T5 aluminum S82 W18717 GEMINI DRIVE P.O. BOX 906 MUSKEGO, WISCONSIN 53150 TOLL FREE PHONE: 1-877-622-2694 FAX: (262) 679-2505 249009 249010 249011 149014 149088 149359 149085 149086 148922 149016 149017 145840 242497 142336 142335 NABCO Part No. Material List Use (7) 1/4" x 3 1/4" Zinc Tek (Broward bolt) pairs at 12" o.c. starting 9 3/4" from each corner, total of (14) anchors Header (Ext.) Roller Track (Ext.) Cover (Ext.) Door Carrier (Ext.) Top Rail - Sidelite (Ext.) Top Rail - Door (Ext.) Bottom Rail - All (Ext.) Pivot Stile (Ext.) Stile (Ext.) Threshold (Ext.) Floor Track Ramp (Ext.) Angle (Ext.) Jamb (Ext.) Glass Stop Base (Ext.) Glass Stop Channel (Ext.) Description Min 1/8" thick 6063-T5 Aluminum use (4) 1/4" - 14 x 1 1/4" Hilti HWH self drilling screws with minimum 1" embedment in Aluminum at each sash corner, a total of (32) in all at header Min 1/8" thick 6063-T5 Aluminum Mounting Screws (Pairs) Header 3/16" use (6) 1/4" x 2 3/4" ITW Buildex PFH Tapcons with minimun 1 3/4"embedment in 3500 psi concrete at each sash corner, a total of (48) in all at threshold 2 1/8" Weathering Pile (Schelegel Polybond) 1/4" Max Shim Space 3500 PSI Concrete Fastener Type, Spacing and Quantity Fastener Chart Panel Stile 1 3/4" Threshold 2 1/8" Weathering Strip Panel Stile Substrate 3" 2 1/8" Door Stile Pivot Rod Jamb Tube 4 1/2" x 1 3/4" x 1/8" Location Exterior Interior DIMENSION DIMENSION DIMENSION DIMENSION "D" DIMENSION DIMENSION DIMENSION "G" OPENING DIMENSION "A" "B" "C" (Door Panel Width) "E" "F" Daylight Opening Incl. 1/4" shim each side 48" 54" 10'-0" 29 1/4" 23" 31 1/16" 24 13/16" 10' 1/2" 60" 66" 12'-0" 35 1/4" 29" 37 1/16" 30 13/16" 12' 1/2" 72" 78" 14'-0" 41 1/4" 35" 43 1/16" 36 13/16" 14' 1/2" 84" 90" 16'-0" 47 1/4" 41" 49 1/16" 42 13/16" 16' 1/2" "G" "F" 2 1/8" Kawneer #37227 Door Stile Pivot Rod Weathering Strip Flush Bolt & Lock Rod Detail 35.0" 1/4" Max Shim Space 3/4" 4 1/2" 3" Mounting Screws (Pairs) 1 3/4" Jamb Tube 4 1/2" x 1 3/4" x 1/8" P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System NABCO ENTRANCES INC. 877-622-2694 – www.nabcoentrances.com 4" Typ Bottom Rail 43 1/8" Max D/O "O" 3500 PSI Concrete 3500 PSI Concrete 3500 PSI Concrete Threshold Header Jambs 2" Typ SX 2" Typ 4" Typ 4" Typ Bottom Rail "SX" Top Rail 6" Typ 4" Typ 6" Typ 4" Typ .77" .69" Typ 1.1" Typ .88" 1/4 - 20 x 7/16" Ph. Hd. Machine Screw Plt'd Steel WHERE WATER INFILTRATION WHERE WATER INFILTRATION REQUIREMENT IS NEEDED REQUIREMENT IS NOT NEEDED Positive NOT APPROVED +60 PSF Negative NOT APPROVED -60 PSF O "Y" "X" 2" Typ 4" Typ Bottom Rail "O" Top Rail Bottom Rail 4" Typ Detail "B" 1.12" Typ 1/2" Typ Stile Detail "D" Detail "B" 1/4 - 20 x 3/4" Ph. Hd. Machine Screw Plt'd Steel Detail "C" Stile Jamb Tube 3 1/4" 1 3/4" Exterior R/H Carrier 6 1/2" 3 1/2" 1/4" 1/2" Tie Rods 3/8" x 46 1/8" Max 29MAY01 01JUL98 01APR97 DATE S82 W18717 GEMINI DRIVE P.O. BOX 906 MUSKEGO, WISCONSIN 53150 TOLL FREE PHONE: 1-877-622-2694 FAX: (262) 679-2505 SECTION "Y-Y" Mounting Screw Pairs Threshold Interior REVISIONS Updated 1 REVISED 0 INITIAL ISSUE REV DESCRIPTION 2 Threshold Ramp (Both Sides) 3 7/16" .72 Typ Detail "A" Stile Top Rail 1/4 - 20 x 7/16" Ph. Hd. Machine Screw Plt'd Steel Header .63" 1/4 - 20 x 3/4" Ph. Hd. Machine Screw Plt'd Steel Top Rail A7 .72 Typ 1/4 - 20 x 7/16" Ph. Hd. Machine Screw Plt'd Steel 1/4 - 20 x 3/4" Ph. Hd. Machine Screw Plt'd Steel 4 1/8" Jamb Tube .66" Lock Reinforcement Plate 1 1/2" x 15" x .105" (12 Ga) .72" Typ .59" 1/4" Max Shim Space Dlubak Technologies Laminated/Tempered Glass (Typical) Reinforcement 3/4" x 3/4" x 1/8" Aluminum Angle Mounting Screws (Pairs) Glass Stop Base 142336 #10 - 24 x PFH Thread Forming Staggered 2" From Each End 4-6" O.C. Typical Glazing Detail Entire Perimeter all Lites Dow 995 Silicone (Typical) 1/2" Glass Bite Detail "C" 1" Sidelite Attached to Header, Threshold and Jamb with (4) 10 Gauge Steel Angle Brackets "Z" 12" Typ 4" Typ 6" Typ 9 3/4" Typ 1.0" Typ Detail "A" 4" Typ 6" Typ "Y" "X" Bottom Rail 1/4 - 20 x 3/4" Ph. Hd. Machine Screw Plt'd Steel Detail "D" Stile EXTERIOR ELEVATION ACCESS COVER (EXTERIOR) SIDE SX Design Pressure Rating Substrate Location O Header Bottom Rail 35" "SX" Top Rail Kawneer Flush Bolt (Typical) (See Sheet 2) 70 1/2" Max D/O Top Rail 4" Typ Adams Rite #1853A/505 Maximum Security Lock Extending Into Header and Threshold (See Sheet 2) 9 3/4" 12" Typ 91 1/2" Max "Z" 12" Typ 9 3/4" Typ Door Pivot (See Page 2) 1 1/2" 70 1/4" MAX D/O 3/16" Tempered Glass 7 1/2" 7'-7 1/2" FRAME HEIGHT 1 3/4" 1 1/2" Header 1/4" Max Shim Space Interior Concrete Construction SECTION "X-X" Door Sweep Tie Rods Torque Pressure Is 15-20 Ft. Lbs. Exterior Weathering Pile (Schelegel Polybond) Cover L/H Carrier 6 1/2" 3 1/2" DRAWING NUMBER: 1175-02C Page 1 of 6 CONCRETE BUILDING FRAME CONSTRUCTION STANDARD ELEVATIONS & SECTIONS SYSTEM GT1175 BIPART SLIDER - FIXED SIDELITE 7'-0" 1/8" Solutia Saflex III G Interlayer 3/16" Tempered Glass #10 x 2" @ 12" o.c. except near corner @ 3" o.c. Glass Stop Channel 142335 1" 6'-11" DOOR OPENING HEIGHT All Anchors are in Pairs 192" Max 4" 4" 1 1/4" 6 1/2" 70 1/2" MAX D/O 38 5" Reference Fastener Chart for Anchors P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System NABCO ENTRANCES INC. 39 3/4" 3" 1 3/4" 2" 877-622-2694 – www.nabcoentrances.com 14 1/8" Typ Panel Stile Kawneer #37227 Jamb Tube 4 1/2" x 1 3/4" x 1/8" Door Stile Pivot Rod Weathering Strip TYPE DIMENSION DIMENSION DIMENSION DIMENSION "D" "A" "B" "C" (Door Panel Width) 4'-0" 48" 54" 10'-0" 29 1/4" 5'-0" 60" 66" 12'-0" 35 1/4" 6'-0" 72" 78" 14'-0" 41 1/4" 7'-0" 84" 90" 16'-0" 47 1/4" Flush Bolt & Lock Rod Detail 35.0" 14 1/8" Typ 5/8" Typ Rod Engagement 1/4" Max Shim Space 4 1/2" Mounting Screws (Pairs) "F" "G" Door Stiles "C" 2 1/8" 2 1/8" "A" "B" DIMENSION "E" 23" 29" 35" 41" 249009 249010 249011 149014 149088 149359 149085 149087 149086 148922 149501 149016 149017 145840 242497 142336 142335 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6005 - T5 aluminum 6005 - T5 aluminum 6061 - T6 aluminum 6063 - T5 aluminum 6063 - T5 aluminum 6063 - T5 aluminum Composition 0 1 Updated Drawing REVISED INITIAL ISSUE REV DESCRIPTION 2 REVISIONS William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. DIMENSION DIMENSION "G" Opening Dimension "F" Daylight Opening (Incl. 1/4" shim each side) 31 1/4" 25 1/8" 10' 1/2" 37 1/4" 31 1/8" 12' 1/2" 43 1/4" 37 1/8" 14' 1/2" 49 1/4" 43 1/8" 16' 1/2" Header (Ext.) Roller Track (Ext.) Cover (Ext.) Door Carrier (Ext.) Top Rail - Sidelite (Ext.) Top Rail - Door (Ext.) Bottom Rail - Door (Ext.) Bottom Rail - Sidelite (Ext.) Pivot Stile (Ext.) Stile (Ext.) Fixed Vert. Mullion (Ext.) Threshold (Ext.) Floor Track Ramp (Ext.) Angle (Ext.) Jamb (Ext.) Glass Stop Base (Ext.) Glass Stop Channel (Ext.) NABCO Part No. Manufacturer Use (7) 1/4" x 3 3/4" ITW Buildex PFH Tapcons in pairs at 12" o.c. starting 9 3/4" from each corner, a total of (14) anchors 3500 PSI Concrete Jamb Material List Use (4) 1/4" x 2 3/4" ITW Buildex PFH Tapcons with minimun 1 3/4"embedment in 3500 psi concrete at each sash corner for intermediate sashes, (4) at corner of jamb and header, a total of (32) in all at header Description 2 1/8" 2 1/8" 29May01 01JUL98 01APR97 DATE Weathering Pile (Amesbury - Center Fin) Use (4) 1/4" x 2 3/4" ITW Buildex PFH Tapcons with minimun 1 3/4"embedment in 3500 psi concrete at each sash corner, (2) at corner of jamb and threshold, a total of (28) in all with full threshold "E" "D" 3500 PSI Concrete 3500 PSI Concrete Threshold Fastener Chart Fastener Type, Spacing and Quantity Exterior Interior 3" Header Substrate SECTION "Z-Z" "E" "D" Panel Stile Location 2 1/8" 2 1/8" 3" Pivot Stile 3.5" Top Rail Mounting Screws (Pairs) 1/4" Max Shim Space DRAWING NUMBER: 1175-02C Page 2 of 6 CONCRETE BUILDING FRAME CONSTRUCTION STANDARD ELEVATIONS & SECTIONS SYSTEM GT1175 BIPART SLIDER - FIXED SIDELITE Concrete Construction (2) 1/4 - 20 x 1 3/4" Hex Head Capscrew Gr. 5 (2) 3/8 - 16 x 1 1/2" Holocrome Low Head Socket Capscrew 1 3/4" A8 Typical Door Pivot Pre-Load Block Carrier Bar Weldment 2" Jamb Tube 4 1/2" x 1 3/4" x 1/8" Panel Stile Carrier 2.06" 4.0" S82 W18717 GEMINI DRIVE P.O. BOX 906 MUSKEGO, WISCONSIN 53150 TOLL FREE PHONE: 1-877-622-2694 FAX: (262) 679-2505 1.75" Typ Pivot Rod 1.0" Dia. 1.0" Door Stile Pivot Rod Weathering Strip Panel Stile "F" "G" P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System NABCO ENTRANCES INC. 877-622-2694 – www.nabcoentrances.com 4" Typ Bottom Rail 43 1/8" Max D/O "O" 70 1/2" Max D/O Top Rail 4" Typ Header Bottom Rail 35" "SX" Top Rail 2" Typ Min. 1/8" thick steel Min. 1/8" thick steel Header Jambs Positive Negative 3500 PSI Concrete Threshold 4" Typ SX 2" Typ 4" Typ 4" Typ Bottom Rail "SX" Top Rail 4" Typ .77" .69" Typ 1.1" Typ .88" 1/4 - 20 x 7/16" Ph. Hd. Machine Screw Plt'd Steel WHERE WATER INFILTRATION WHERE WATER INFILTRATION REQUIREMENT IS NEEDED REQUIREMENT IS NOT NEEDED NOT APPROVED +60 PSF -60 PSF NOT APPROVED O "Y" "X" 2" Typ 4" Typ Bottom Rail "O" Top Rail 4" Typ Detail "B" 1.12" Typ 1/2" Typ Stile Detail "D" Detail "B" Detail "C" Stile Jamb Tube 3 7/16" .72 Typ 1 1 1/2" 3 1/4" 1 3/4" Exterior R/H Carrier 6 1/2" 3 1/2" 1/4" 1/2" Tie Rods 3/8" x 46 1/8" Max 29MAY01 01JUL98 01APR97 DATE S82 W18717 GEMINI DRIVE P.O. BOX 906 MUSKEGO, WISCONSIN 53150 TOLL FREE PHONE: 1-877-622-2694 FAX: (262) 679-2505 SECTION "Y-Y" Mounting Screw Pairs Threshold Interior REVISIONS Updated REVISED 0 INITIAL ISSUE REV DESCRIPTION 2 Threshold Ramp (Both Sides) 1/4 - 20 x 3/4" Ph. Hd. Machine Screw Plt'd Steel 1/4 - 20 x 7/16" Ph. Hd. Machine Screw Plt'd Steel Top Rail Detail "A" Stile Header .63" 1/4 - 20 x 3/4" Ph. Hd. Machine Screw Plt'd Steel Top Rail A9 .72 Typ 1/4 - 20 x 7/16" Ph. Hd. Machine Screw Plt'd Steel 1/4 - 20 x 3/4" Ph. Hd. Machine Screw Plt'd Steel 4 1/8" Jamb Tube .66" Lock Reinforcement Plate 1 1/2" x 15" x .105" (12 Ga) .72" Typ .59" Typical Glazing Detail Entire Perimeter all Lites Dow 995 Silicone (Typical) 1/2" Glass Bite Detail "C" 1" Sidelite Attached to Header, Threshold and Jamb with (4) 10 Gauge Steel Angle Brackets "Z" 12" Typ 9 3/4" Typ 4" Typ Bottom Rail 1.0" Typ Detail "A" 4" Typ 2" Typ "Y" "X" Bottom Rail 1/4 - 20 x 3/4" Ph. Hd. Machine Screw Plt'd Steel Detail "D" Stile EXTERIOR ELEVATION ACCESS COVER (EXTERIOR) SIDE SX Design Pressure Rating Substrate Location O 2" Typ Adams Rite #1853A/505 Maximum Security Lock Extending Into Header and Threshold (See Sheet 2) Kawneer Flush Bolt (Typical) (See Sheet 2) 9 3/4" 12" Typ 91 1/2" Max "Z" 12" Typ 9 3/4" Typ 2" Typ 1/4" Max Shim Space Dlubak Technologies Laminated/Tempered Glass (Typical) Reinforcement 3/4" x 3/4" x 1/8" Aluminum Angle Mounting Screws (Pairs) Glass Stop Base 142336 #10 - 24 x PFH Thread Forming Staggered 2" From Each End 4-6" O.C. 3/16" Tempered Glass 70 1/4" MAX D/O 1/8" Solutia Saflex III G Interlayer 3/16" Tempered Glass #10 x 2" @ 12" o.c. except near corner @ 3" o.c. Glass Stop Channel 142335 1" 6'-11" DOOR OPENING HEIGHT All Anchors are in Pairs 192" Max 7 1/2" 7'-7 1/2" FRAME HEIGHT 1 3/4" 1 1/2" Steel Construction Header 1/4" Max Shim Space SECTION "X-X" Door Sweep Tie Rods Torque Pressure Is 15-20 Ft. Lbs. Exterior Weathering Pile (Schelegel Polybond) Cover L/H Carrier 6 1/2" 3 1/2" Interior DRAWING NUMBER: 1175-02S Page 3 of 6 STEEL BUILDING FRAME CONSTRUCTION STANDARD ELEVATIONS & SECTIONS SYSTEM GT1175 BIPART SLIDER - FIXED SIDELITE 7'-0" Reference Fastener Chart for Anchors 4" 4" 1 1/4" 6 1/2" 70 1/2" MAX D/O 40 5" Door Pivot (See Page 2) P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System NABCO ENTRANCES INC. 41 3/4" 3" 1 3/4" 2" 877-622-2694 – www.nabcoentrances.com 14 1/8" Typ Panel Stile Kawneer #37227 Jamb Tube 4 1/2" x 1 3/4" x 1/8" Door Stile Pivot Rod Weathering Strip TYPE DIMENSION DIMENSION DIMENSION DIMENSION "D" "A" "B" "C" (Door Panel Width) 4'-0" 48" 54" 10'-0" 29 1/4" 5'-0" 60" 66" 12'-0" 35 1/4" 6'-0" 72" 78" 14'-0" 41 1/4" 7'-0" 84" 90" 16'-0" 47 1/4" Flush Bolt & Lock Rod Detail 35.0" 14 1/8" Typ 5/8" Typ Rod Engagement 1/4" Max Shim Space 4 1/2" Mounting Screws (Pairs) "F" "G" Door Stiles "C" 2 1/8" 2 1/8" "A" DIMENSION "E" 23" 29" 35" 41" Composition 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6005 - T5 aluminum 6005 - T5 aluminum 6061 - T6 aluminum 6063 - T5 aluminum 6063 - T5 aluminum 6063 - T5 aluminum REVISIONS Updated Drawing 1 REVISED 0 INITIAL ISSUE REV DESCRIPTION 2 William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. DIMENSION DIMENSION "G" Opening Dimension "F" Daylight Opening (Incl. 1/4" shim each side) 31 1/4" 25 1/8" 10' 1/2" 37 1/4" 31 1/8" 12' 1/2" 43 1/4" 37 1/8" 14' 1/2" 49 1/4" 43 1/8" 16' 1/2" 249009 249010 249011 149014 149088 149359 149085 149087 149086 148922 149501 149016 149017 145840 242497 142336 142335 NABCO Part No. Header (Ext.) Roller Track (Ext.) Cover (Ext.) Door Carrier (Ext.) Top Rail - Sidelite (Ext.) Top Rail - Door (Ext.) Bottom Rail - Door (Ext.) Bottom Rail - Sidelite (Ext.) Pivot Stile (Ext.) Stile (Ext.) Fixed Vert. Mullion (Ext.) Threshold (Ext.) Floor Track Ramp (Ext.) Angle (Ext.) Jamb (Ext.) Glass Stop Base (Ext.) Glass Stop Channel (Ext.) 29May01 01JUL98 01APR97 DATE Use (7) 1/4" - 14 x 3 1/4" Hilti HWH self drilling screws with minimum 1" embedment in Steel in pairs at 12" o.c. starting 9 3/4" from each corner, total of (14) anchors Min 1/8" thick Steel Jamb Manufacturer Use (4) 1/4" - 14 x 1 1/4" Hilti HWH self drilling screws with minimum 1" embedment in Steel at each sash corner for intermediate sashes, (2) at corner of jamb and header, a total of (28) in all at header Min 1/8" thick Steel Header Description Use (4) 1/4" x 2 3/4" ITW Buildex PFH Tapcons with minimun 1 3/4" embedment in 3500 psi concrete at each sash corner, (2) at corner of jamb and threshold, a total of (28) in all with full threshold 3500 PSI Concrete Material List 2 1/8" 2 1/8" Weathering Pile (Amesbury - Center Fin) Threshold "E" "D" 3" Fastener Type, Spacing and Quantity Exterior Interior Substrate Fastener Chart SECTION "Z-Z" "E" "D" Panel Stile "B" Location 2 1/8" 2 1/8" 3" Pivot Stile 3.5" Top Rail Mounting Screws (Pairs) 1/4" Max Shim Space (2) 1/4 - 20 x 1 3/4" Hex Head Capscrew Gr. 5 (2) 3/8 - 16 x 1 1/2" Holocrome Low Head Socket Capscrew 1 3/4" DRAWING NUMBER: 1175-02S Page 4 of 6 STEEL BUILDING FRAME CONSTRUCTION STANDARD ELEVATIONS & SECTIONS SYSTEM GT1175 BIPART SLIDER - FIXED SIDELITE Steel Construction A10 Typical Door Pivot Pre-Load Block Carrier Bar Weldment 2" Jamb Tube 4 1/2" x 1 3/4" x 1/8" Panel Stile Carrier 2.06" 4.0" S82 W18717 GEMINI DRIVE P.O. BOX 906 MUSKEGO, WISCONSIN 53150 TOLL FREE PHONE: 1-877-622-2694 FAX: (262) 679-2505 1.75" Typ Pivot Rod 1.0" Dia. 1.0" Door Stile Pivot Rod Weathering Strip Panel Stile "F" "G" P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System NABCO ENTRANCES INC. 877-622-2694 – www.nabcoentrances.com 4" Typ Bottom Rail 43 1/8" Max D/O "O" 2" Typ SX 2" Typ SX 2" Typ 4" Typ 4" Typ Bottom Rail "SX" Top Rail 4" Typ 4" Typ 3500 PSI Concrete Min 1/8" thick 6063-T5 Aluminum Min 1/8" thick 6063-T5 Aluminum Threshold Header Jamb .77" .69" Typ 1.1" Typ .88" Bottom Rail 1/4 - 20 x 3/4" Ph. Hd. Machine Screw Plt'd Steel 1/4 - 20 x 7/16" Ph. Hd. Machine Screw Plt'd Steel Detail "D" Stile O "Y" "X" 2" Typ 4" Typ Bottom Rail "O" Top Rail 4" Typ Detail "B" 1.12" Typ 1/2" Typ Stile Detail "D" Detail "B" .66" 1/4 - 20 x 7/16" Ph. Hd. Machine Screw Plt'd Steel 1/4 - 20 x 3/4" Ph. Hd. Machine Screw Plt'd Steel Stile Detail "C" 1/4 - 20 x 3/4" Ph. Hd. Machine Screw Plt'd Steel Top Rail A11 .72 Typ 4 1/8" Jamb Tube 1/4 - 20 x 3/4" Ph. Hd. Machine Screw Plt'd Steel Top Rail 1/4 - 20 x 7/16" Ph. Hd. Machine Screw Plt'd Steel 2 3 1/4" 1 3/4" Exterior R/H Carrier 6 1/2" 3 1/2" 1/4" 1/2" Tie Rods 3/8" x 46 1/8" Max 29MAY01 01JUL98 01APR97 DATE S82 W18717 GEMINI DRIVE P.O. BOX 906 MUSKEGO, WISCONSIN 53150 TOLL FREE PHONE: 1-877-622-2694 FAX: (262) 679-2505 SECTION "Y-Y" Mounting Screw Pairs Threshold Interior REVISIONS Updated 1 REVISED 0 INITIAL ISSUE REV DESCRIPTION Threshold Ramp (Both Sides) Jamb Tube 3 7/16" .72 Typ Detail "A" Stile Lock Reinforcement Plate 1 1/2" x 15" x .105" (12 Ga) .72" Typ .59" Header .63" 1/4" Max Shim Space Dlubak Technologies Laminated/Tempered Glass (Typical) Reinforcement 3/4" x 3/4" x 1/8" Aluminum Angle Mounting Screws (Pairs) Glass Stop Base 142336 #10 - 24 x PFH Thread Forming Staggered 2" From Each End 4-6" O.C. Typical Glazing Detail Entire Perimeter all Lites Dow 995 Silicone (Typical) 1/2" Glass Bite Detail "C" 1" Sidelite Attached to Header, Threshold and Jamb with (4) 10 Gauge Steel Angle Brackets "Z" 12" Typ 9 3/4" Typ 4" Typ Bottom Rail 1.0" Typ Detail "A" 4" Typ 2" Typ "Y" "X" WHERE WATER INFILTRATION WHERE WATER INFILTRATION REQUIREMENT IS NOT NEEDED REQUIREMENT IS NEEDED Positive NOT APPROVED +60 PSF Negative NOT APPROVED -60 PSF Design Pressure Rating Substrate EXTERIOR ELEVATION ACCESS COVER (EXTERIOR) SIDE Location O Header Bottom Rail 35" "SX" Top Rail 2" Typ Kawneer Flush Bolt (Typical) (See Sheet 2) 70 1/2" Max D/O Top Rail Adams Rite #1853A/505 Maximum Security Lock Extending Into Header and Threshold (See Sheet 2) 9 3/4" 12" Typ 91 1/2" Max "Z" 12" Typ 4" Typ 9 3/4" Typ Door Pivot (See Page 2) 1 1/2" 70 1/4" MAX D/O 3/16" Tempered Glass 1" 6'-11" DOOR OPENING HEIGHT 1/8" Solutia Saflex III G Interlayer 3/16" Tempered Glass #10 x 2" @ 12" o.c. except near corner @ 3" o.c. Glass Stop Channel 142335 7 1/2" 1 3/4" 1 1/2" Header 1/4" Max Shim Space SECTION "X-X" Door Sweep Tie Rods Torque Pressure Is 15-20 Ft. Lbs. Exterior Weathering Pile (Schelegel Polybond) Cover L/H Carrier 6 1/2" 3 1/2" Aluminum Construction 7'-7 1/2" FRAME HEIGHT Interior DRAWING NUMBER: 1175-02A Page 5 of 6 ALUMINUM BUILDING FRAME CONSTRUCTION STANDARD ELEVATIONS & SECTIONS SYSTEM GT1175 BIPART SLIDER - FIXED SIDELITE 7'-0" All Anchors are in Pairs 192" Max 4" 4" 1 1/4" 6 1/2" 70 1/2" MAX D/O 42 5" Reference Fastener Chart for Anchors P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System NABCO ENTRANCES INC. 43 3/4" 3" 1 3/4" 2" 877-622-2694 – www.nabcoentrances.com 14 1/8" Typ Panel Stile Kawneer #37227 Jamb Tube 4 1/2" x 1 3/4" x 1/8" Door Stile Pivot Rod Weathering Strip TYPE DIMENSION DIMENSION DIMENSION DIMENSION "D" "A" "B" "C" (Door Panel Width) 4'-0" 48" 54" 10'-0" 29 1/4" 5'-0" 60" 66" 12'-0" 35 1/4" 6'-0" 72" 78" 14'-0" 41 1/4" 7'-0" 84" 90" 16'-0" 47 1/4" Flush Bolt & Lock Rod Detail 35.0" 14 1/8" Typ 5/8" Typ Rod Engagement 1/4" Max Shim Space 4 1/2" Mounting Screws (Pairs) "F" "G" Door Stiles "C" 2 1/8" 2 1/8" "B" "A" DIMENSION "E" 23" 29" 35" 41" Composition 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6063 - T6 aluminum 6005 - T5 aluminum 6005 - T5 aluminum 6061 - T6 aluminum 6063 - T5 aluminum 6063 - T5 aluminum 6063 - T5 aluminum 0 1 Updated Drawing REVISED INITIAL ISSUE REV DESCRIPTION 2 REVISIONS William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. William L. Bonnell Co. DIMENSION DIMENSION "G" Opening Dimension "F" Daylight Opening (Incl. 1/4" shim each side) 31 1/4" 25 1/8" 10' 1/2" 37 1/4" 31 1/8" 12' 1/2" 43 1/4" 37 1/8" 14' 1/2" 49 1/4" 43 1/8" 16' 1/2" 249009 249010 249011 149014 149088 149359 149085 149087 149086 148922 149501 149016 149017 145840 242497 142336 142335 NABCO Part No. Header (Ext.) Roller Track (Ext.) Cover (Ext.) Door Carrier (Ext.) Top Rail - Sidelite (Ext.) Top Rail - Door (Ext.) Bottom Rail - Door (Ext.) Bottom Rail - Sidelite (Ext.) Pivot Stile (Ext.) Stile (Ext.) Fixed Vert. Mullion (Ext.) Threshold (Ext.) Floor Track Ramp (Ext.) Angle (Ext.) Jamb (Ext.) Glass Stop Base (Ext.) Glass Stop Channel (Ext.) Manufacturer 29May01 01JUL98 01APR97 DATE Use (7) 1/4" - 14 x 3 1/4" Hilti HWH self drilling screws with minimum 1" embedment in Aluminum pairs at 12" o.c. starting 9 3/4" from each corner, total of (14) anchors Min 1/8" thick 6063-T5 Aluminum Jamb Description Use (4) 1/4" - 14 x 1 1/4" Hilti HWH self drilling screws with minimum 1" embedment in Aluminum at each sash corner for intermediate sashes, (2) at corner of jamb and header, a total of (28) in all at header Material List 2 1/8" 2 1/8" Weathering Pile (Amesbury - Center Fin) Use (4) 1/4" x 2 3/4" ITW Buildex PFH Tapcons with minimun 1 3/4" embedment in 3500 psi concrete at each sash corner, (2) at corner of jamb and threshold, a total of (28) in all with full threshold "E" "D" Min 1/8" thick 6063-T5 Aluminum 3500 PSI Concrete Threshold Fastener Chart Fastener Type, Spacing and Quantity Exterior Interior 3" Header Substrate SECTION "Z-Z" "E" "D" Panel Stile Location 2 1/8" 2 1/8" 3" Pivot Stile 3.5" Top Rail 1 3/4" Mounting Screws (Pairs) 1/4" Max Shim Space (2) 1/4 - 20 x 1 3/4" Hex Head Capscrew Gr. 5 (2) 3/8 - 16 x 1 1/2" Holocrome Low Head Socket Capscrew DRAWING NUMBER: 1175-02A Page 6 of 6 ALUMINUM BUILDING FRAME CONSTRUCTION STANDARD ELEVATIONS & SECTIONS SYSTEM GT1175 BIPART SLIDER - FIXED SIDELITE Aluminum Construction A12 Typical Door Pivot Pre-Load Block Carrier Bar Weldment 2" Jamb Tube 4 1/2" x 1 3/4" x 1/8" Panel Stile Carrier 2.06" 4.0" S82 W18717 GEMINI DRIVE P.O. BOX 906 MUSKEGO, WISCONSIN 53150 TOLL FREE PHONE: 1-877-622-2694 FAX: (262) 679-2505 1.75" Typ Pivot Rod 1.0" Dia. 1.0" Door Stile Pivot Rod Weathering Strip Panel Stile "F" "G" P/N 14-10275 December 30, 2014 Revision Model 1175 (H60-Narrow) Hurricane Slide Door System NABCO ENTRANCES INC.
advertisement
Key Features
- Dade County Approved
- Hurricane Resistant
- Secure and Weather-Tight
- Easy to Install and Operate
- Safety Features
Frequently Answers and Questions
How do I adjust the door preload?
Panic the door open to check door sag. Loosen the two locking bolts on the block inside the top rail of the door. Adjust door sag by rotating the setscrew on the back edge of the door with a 1/8-inch allen wrench. The door should latch without having to adjust the panel. A longer setscrew is provided in the parts box if required. Retighten locking bolts.
What are the common replacement parts?
The common replacement parts are: Motor alone, Operator alone, Motor & Operator assy, GYRO TECH, Key Switches, Harness, MICROPROCESSOR CONTROLLER, Door Roller Assembly, Track Cap (for damaged track), Weather Strip, Door Roller/Cover, Anti-Rise Axle Assembly, Bearing, Left Hand Fixed Sidelight Bottom Guide, Idler Assembly, Pulley Only, Full Open Bottom Guide, Right Hand Fixed Sidelight Bottom Guide Full Open and Fixed Sidelight
How do I adjust the belt tension?
Loosen the mounting nuts on the idler bracket. Loosen the lock nut on the tension adjustment screw. Turn the tension adjustment screw to tighten or loosen the belt. The screw should push the idler bracket in the header. If the idler bracket does not move, loosen the two mounting nuts a few more turns. Tension the belt so it is to approximately the same tension as received from the factory. It should not be so taut that it bends the drive or idler shafts! Tighten the lock nut on the adjustment screw against the bracket a secure the mounting nuts.