Conditions

Capacity Conditions

Unit cooling and heating capacities shown within this price list are based on the following conditions:

Nominal cooling

Ambient = 35°C

Internal = 27°C db 19°C wb

Nominal heating

Ambient = 7°C db 6°C wb

Internal = 20°C db

UK cooling

Ambient = 30°C

Internal = 22°C db 16°C wb

Heat Source

Unless otherwise indicated, all units within this price list are air-cooled.

Seasonal Efficiency

Split and Sky Air

Systems of up to 12kW must now show Seasonal

Efficiency Ratings instead of Nominal Efficiency Ratings.

These ratings (SEER for cooling, SCOP for heating) represent how effective a system is throughout the year, and are in accordance with EN14825.

For more information on Seasonal Efficiency, visit www.daikin.co.uk/seasonal-efficiency

For Daikin UK, this means all our Split and Sky Air products up to 12kW display SEER and SCOP data along with Energy Label information and Annual Energy

Consumption of the system. The AEC is based upon

500 hours use per year.

VRV (ESEER)

ESEER is defined as the European Seasonal Energy

Efficiency Ratio and is a measure of the performance of the outdoor unit only.

Nominal Efficiency

This measure of efficiency is calculated by dividing the capacity output of a unit by the power required to deliver it.

For cooling, this is expressed as EER, for heating as COP.

Nominal efficiencies are used for systems above 12kW.

It is not possible to compare nominal and Seasonal

Efficiency ratings.

Daikin UK Price List 2015

Contents

New for 2015

Split, Sky Air Heat Pumps

VRV

Ventilation

Heating

Applied

Miscellaneous

43

87

2

5

89

131

143

Discount Rating

Please insert your discounts here and then refer to the colour tabs on the edge of each page for reference.

Ventilation

MY DISCOUNT

%

Split, Sky Air Heat Pumps

MY DISCOUNT

%

Heating

MY DISCOUNT

%

VRV

MY DISCOUNT

%

Applied

MY DISCOUNT

%

Price List 2015 1

New for 2015

Mini-VRV

VRV IV comes to the mini range

Low height mini range

> Only 823mm high – simple installation

> 4 & 5HP capacity

> Variable Refrigerant Temperature

> AHU and Air Curtain connection possibilities

Extended capacity range

> 8, 10 & 12HP twin fan horizontal airflow

> For larger capacity Mini VRV installations

Standard VRV IV 4/5/6HP ranges

> Variable Refrigerant Temperature

> LT Hot water / AHU / Air Curtain connectivity

NEW

COMING

SOON

NEW

FOR 2015

FTXB-C wall mounted units

> Wide range of capacities

> 2.0kW / 2.5kW / 3.5kW / 5.0kW / 6.0kW

> Infrared remote control

> Cooling down to -10°C ambient

> Powerful mode

> Auto-swing

> Pair with RXB-C outdoor units

Page 66 / 67

FNQ-A / FXNQ-A vertical chassis unit

> Slim width chassis for installation under windows or in bulkheads

> New 2kW to 6kW model for connection to Split / Sky or Multi

> External Static Pressure of up to 44Pa

> VRV replaces UK.FXDQ model

2 Residential, Commercial and Industrial

Page 6 / 7

NEW

COMING

SOON

Page 27 / 50

FBQ-D / FXSQ-A High Static Ducted units

> Upgrade to existing range of ducted units

> Reduced unit height to 245mm

> External Static Pressure of 150Pa

> VRV range extended to include 15 class

NEW

FOR 2015

NEW

FOR 2015

Page 28 / 29 / 31 / 48

Multi-boxes for VRV-Q

> Upgrade to VRV-Q and VRV-W outdoor units

> Allows connection to the versatile range of VRV IV single

& multi BS boxes

> VRV IV range of single & multi BS box becomes standard range

Page 79

EKMBDXA Modbus Interface

> Integrated control system for seamless connection between

Sky Air or VRV equipment and BMS systems

> Communication via Modbus RS485

> Connects directly to Daikin DIII-net protocol

NEW

FOR 2015

Page 82

NEW

FOR 2015

Simplified remote control solution for hotels

> Wall mounted remote with or without heat /cool button

> Stylish chrome or brass facia options available

> BRP7A51 adaptor connects fancoil to key-card and window contacts

> BRP7A51 implements control strategy based on key-card or window status

Page 81

Heating

Our Residential, Commercial & Industrial Price list now includes details of our domestic heating range including:

> Altherma air-to-water heat pumps – including Monobloc

> Altherma Hybrid heat pump system

> Solar thermal & underfloor heating products

NEW

FOR 2015

Page 89 - 130

Price List 2015 3

Daikin UK Price List 2015

Split, Sky Air Heat Pumps

FTXB-C Wall Mounted Units

6

Enhanced Capital Allowance (ECA) Scheme

6

Pair Applications

7

Wall Mounted Split Systems

Floor Standing Split Systems

7

12

Flexi Type Split Systems

Ceiling Suspended Split Systems

Under Ceiling Cassette Split Systems

Cassette Split Systems

Ducted Split Systems

16

17

21

22

28

Multi Applications

34

Multi Split Systems 34

Twin, Triple, Double Twin Systems 36

Scotland

Region

0845 641 9330

Northern

Region

0845 641 9340

Midlands

Region

0845 641 9370

Western

Region

0845 641 9320

North

London

0845 641 9360

South

London

0845 641 9355

FTXB-C Wall Mounted Units

1

PERFECT

COMFORT

2

LOW

SOUND

3

EASY

CONTROL

4

CLEAN

AIR

NEW

FOR 2015

> Wider range: 2.0kW - 6.0kW

> Wider operating range: -10°C ambient

Enhanced Capital Allowance (ECA) Scheme

The Enhanced Capital Allowance (ECA) scheme provides businesses with enhanced tax relief for investment in energy-saving equipment that meets specified Government criteria. It allows 100% of the investment to be written off against taxable profit in the year the investment is made.

Daikin now has a website that allows customers to check whether selected equipment is efficient enough to be eligible to claim

Enhanced Capital Allowances.

Go to www.daikin.co.uk/eca to check:

> Split

> Sky Air

> VRV

The website also allows you to create a Certificate of Eligibilty for your equipment selection that can be used to support a claim for ECA.

The Energy Technology List (ETL) is a definitive list of all the products that qualify for the ECA, typically by meeting or exceeding efficiency standards. For DX, the list covers approximately the top 20% of air conditioning systems and is updated regularly to ensure that it includes the most energy efficient products currently available.

Certain types of equipment are listed on the ECA website.

To check eligibility of the following equipment types, please go to www.etl.decc.gov.uk/etl/site.htm

> Biddle Air Curtains (Split and VRV)

> Ventilation (VAMs)

> Control Options (RTD20)

> Chillers

The ETL website should also be used to check equipment eligibility for Split,

Sky Air & VRV equipment purchasesd before August 2014.

6 Residential, Commercial and Industrial

FTXB / RXB

Wall Mounted – Low Inverter

Indoor Units

Capacity UK Total Cooling

UK Sensible Cooling kW kW

Seasonal Efficiency

(EN14825)

COOLING

Seasonal Efficiency

(EN14825)

HEATING

Nominal Cooling

Nominal Heating

Energy Label

Pdesign kW kW kW

SEER

Annual Energy Consumption kWh

Energy Label

Pdesign kW

SCOP

Annual Energy Consumption kWh

EER / COP Nominal Efficiency

Air Flow Rate

Sound Power

Energy Label

Annual Energy Consumption kWh

High / Low

Dimensions Height

Weight

Sound Pressure

Width

Depth

High / Low / Silent m 3 /min mm mm mm kg dBA dBA

Outdoor Units

Dimensions

Weight

Electrical Details

Height x Width x Depth

Power Supply

Running Current

Starting Current

Max Fuse Size

Interconnection Wiring Core / Cable size

Piping Connections

Pipework

Sound Pressure

Sound Power

Liquid / Gas

Maximum Length

Maximum Vertical Rise

Precharged to

Additional Charge

Holding Charge

High

Trade Fan Coil Price

Trade Condensing Unit Price

Total System Price

mm kg

A

A

A inches m m m g/m kg dBA dBA

1/4 / 3/8

15

12

10

0.7

46

60

£100.00

£298.00

£398.00

FTXB20C

1.96

1.66

2.00

2.50

A+

2.00

5.98

117

A+

2.20

4.10

751

3.94 / 4.19

A / A

254

9.1 / 5.9

39 / 25 / 21

55

RXB20C

27

2.34

3.0

16

RXB25C

550 x 658 x 275

27

1ph

3.69

3.7

16

3+E / 1.5

1/4 / 3/8

15

12

10

Databook

0.7

46

60

FTXB25C

2.44

1.78

2.50

2.80

A+

2.50

6.02

145

A+

2.40

4.01

838

3.25 / 4.01

A / A

385

9.2 / 6.0

283

770

216

8

40 / 26 / 21

55

£107.00

£319.00

£426.00

FTXB20-35C

FTXB35C

3.07

2.11

3.30

4.80

A+

3.30

6.05

191

A+

2.80

4.06

966

3.32 / 3.71

A / A

514

9.3 / 6.1

41 / 27 / 21

58

RXB35C

29

5.34

5.2

16

1/4 / 3/8

15

12

10

0.7

48

62

£124.00

£371.00

£495.00

Accessories:

Accessory Ref

UK.CWB90-2

UK.DT1

UK.CGS

UK.CGM

Description

Condensing unit bracket - up to size 71, max weight 90kg of ODU

Condensate drip tray for use with Split ODU - tray width 800mm

Condensing Unit Guard size 20-35

Condensing Unit Guard size 42-71

Features:

> Wireless remote controller with daily timer function

> Titanium Apatire photocatalytic air purifiying filter: superior purification & deoderisation of air inside room

> Powerful operation: acitivates maximum air volume for 20 minutes

> Auto-swing mode for optimal air flow within the room

> Silent mode can reduce sound levels to 21dBA in the room

Trade Price

£37.00

£56.00

£214.00

£296.00

FTXB50-60C

FTXB50C

4.80

3.19

5.48

5.62

A+

5.48

5.79

331

A+

3.64

4.27

1193

3.32 / 2.75

A / A

854

15.0 11.82

310

1065

224

14

44 / 38 / 32

55

46 / 43 / 37

61

RXB50C

753 x 855 x 328

44

1ph

7.51* tbc

16

3+E / 2.5

1/4 / 5/8

30

10

7.5

Databook

1.0

47

64

RXB60C

44

8,52* tbc

16

1/4 / 1/2

30

10

7.5

1.0

49

65

£181.00

£465.00

£646.00

£214.00

£549.00

£763.00

FTXB60C

5.46

3.83

6.23

6.40

A+

6.23

5.96

366

A+

3.80

4.06

1310

3.23 / 3.81

A / A

964

18.5 / 14.3

Notes: i) All fancoils supplied with infrared remote controller

FTXB20/25/35 with ARC470A1

FTXB50 / 60 with APGS02 ii) All fancoil units standard with auto restart after power failure iii) Minimum ambient operating temperatures:

RXB-C

Cooling

-10°C

Heating

-15°C

Price List 2015 7

FTXS-K/G

Wall Mounted – Inverter

Indoor Units

Capacity UK Total Cooling

UK Sensible Cooling kW kW

Seasonal Efficiency

(EN14825)

COOLING

Seasonal Efficiency

(EN14825)

HEATING

Nominal Cooling

Nominal Heating

Energy Label

Pdesign kW kW kW

SEER

Annual Energy Consumption kWh

Energy Label

Pdesign kW

SCOP

Annual Energy Consumption kWh

EER / COP Nominal Efficiency

Air Flow Rate

Sound Power

Energy Label

Annual Energy Consumption kWh

High / Low

Dimensions Height

Weight

Sound Pressure

Width

Depth

High / Low m 3 /min mm mm mm kg dBA dBA

Outdoor Units

Dimensions

Weight

Electrical Details

Height x Width x Depth

Power Supply

Running Current

Starting Current

Max Fuse Size

Interconnection Wiring Core / Cable size

Piping Connections

Pipework

Sound Pressure

Sound Power

Liquid / Gas

Maximum Length

Maximum Vertical Rise

Precharged to

Additional Charge

Holding Charge

High mm kg

A

A

A inches m m m g/m kg dBA dBA

ECA Eligible

Trade Fan Coil Price

Trade Condensing Unit Price

Total System Price

FTXS20K

1.95

1.65

2.00

2.50

A++

2.00

7.40

95

A++

2.30

4.77

675

4.65 / 4.72

A / A

215

8.8 / 4.7

289

780

215

8

40 / 24

58

RXS20L3

1/4 / 3/8

20

15

10

1.0

46

59

RXS25L3

34

550 x 765 x 285

34

2.30

2.8

10

1ph

3.10

3.3

10

3+E / 1.5

1/4 / 3/8

20

15

10

20

1.0

46

59

FTXS25K

2.44

1.82

2.50

3.40

A++

2.50

7.90

111

A++

2.50

4.78

732

4.39 / 4.67

A / A

285

9.1 / 5

289

780

215

8

41 / 25

58

£154.00

£436.00

£590.00

£165.00

£476.00

£641.00

FTXS-K series

FTXS35K

3.42

2.56

3.50

4.00

A++

3.50

7.47

164

A++

3.60

4.85

1039

4.07 / 4.76

A / A

430

11.2 / 5.8

298

900

215

11

45 / 29

59

FTXS42K

4.11

2.85

A / A

590

11.2 / 7

298

900

215

11

45 / 33

59

4.20

5.40

A++

4.20

6.80

216

A+

4.00

4.20

1334

3.56 / 4.12

RXS35L3 RXS42L

550 x 765 x 285

34 39

4.10

4.3

10

5.70

6.6

20

1/4 / 3/8

20

15

10

1.2

48

61

1/4 / 3/8

20

15

10

1.3

48

61

● ●

FTXS50K

4.56

3.14

5.00

5.80

A++

5.00

6.80

257

A+

4.60

4.20

1535

3.55 / 4

A / A

705

11.9 / 7.4

298

900

215

11

46 / 34

60

RXS50L

47

735 x 825 x 300

48

1ph

6.30

6.8

20

8.80

9.4

20

3+E / 2.5

1/4 / 1/2

30

20

10

20

1.7

48

62

RXS60L

1/4 / 1/2

30

20

10

1.5

49

62

FTXS-G series

FTXS60G

5.86

3.87

6.00

7.00

A

6.00

5.58

376

A

4.80

3.89

1728

3.02 / 3.43

B / B

995

16 / 11.3

290

1050

250

12

45 / 36

61

Accessories:

Accessory Ref

KRP980A1

BRC944

BRP069A42

BRCW901A03

BRCW901A08

KRP928A2S

KLIC-DD

RTD-RA

UK.CWB90-2

UK.DT1

UK.DT2

UK.CGS

UK.CGM

Description

S21 adaptor for FTXS20K & 25K for ALL control options

Optional Wired Remote controller

Wifi adaptor for connection to on-line controller

3m connection cable for BRC944

8m connection cable for BRC944

Adaptor PCB for interface to Daikin centralised control systems

KNX interface for Split type systems

Adaptor PCB for Modbus connection and/or extended system functions

Condensing unit bracket - up to size 71, max weight 90kg of ODU

Condensate drip tray for use with Split ODU - tray width 800mm

Condensate drip tray for use with Sky Air ODU - tray width 1100mm

Condensing Unit Guard size 20-35

Condensing Unit Guard size 42-71

£189.00

£552.00

£741.00

£212.00

£623.00

£835.00

Trade Price

£50.00

£64.00

£50.00

£17.00

£22.00

£132.00

£164.00

£151.00

£37.00

£56.00

£59.00

£214.00

£296.00

£294.00

£694.00

£988.00

£300.00

£740.00

£1,040.00

£400.00

£1,013.00

£1,413.00

Notes: i) All fan coil units standard with auto restart after power failure ii) All fan coils supplied as standard with infrared remote controller iii) Wired controller, KLIC-DI and RTD-RA options cannot be combined iv) FTXS-K and FTXS-G have different style casing v) Minimum ambient operating temperatures:

RXS

Cooling

-10°C

Heating

-15°C

Features:

> Wireless remote controller with weekly timer: provides a 7-day schedule timer, enabling daily or weekly programming. Up to 4 actions per day possible

> Night set mode: prevents sudden changes in room temperature by gently adjusting the temperature before the system stops

> Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room

> 2-area intelligent eye: (35~50 K class) air flow is sent to a zone other than where the occupants are located at that moment

> Presence Sensor switches to energy saving mode if room is unoccupied after 20 mins

WI-FI

CONTR

OL

VIA APP

> Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting

> Fan speed: 5 fan speeds can be selected, high to super low

> Suitable for multi model applications

> Re-use of existing R22 and R407C piping possible

FTXS71G

6.94

4.65

7.10

8.20

A

7.10

5.23

475

A

6.50

3.50

2593

3.02 / 3.22

B / C

1175

17.2 / 11.5

290

1050

250

12

46 / 37

62

RXS71F8

770 x 900 x 320

71

10.49

11.7

20

1/4 / 5/8

30

20

10

2.3

52

65

8 Residential, Commercial and Industrial

Emura

Wall Mounted – Inverter

Indoor Units

Capacity

Seasonal Efficiency

(EN14825)

COOLING

UK Total Cooling

UK Sensible Cooling

Nominal Cooling

Nominal Heating kW kW kW kW

Energy Label

Pdesign kW

SEER

Annual Energy Consumption kWh

Seasonal Efficiency

(EN14825)

HEATING

Weight

Sound Pressure

Sound Power

Energy Label

Pdesign kW

SCOP

Annual Energy Consumption kWh

Nominal Efficiency EER / COP

Energy Label

Air Flow Rate

Annual Energy Consumption kWh

High / Low

Dimensions Height m

3

/min mm

Width

Depth

High / Low mm mm kg dBA dBA

Outdoor Units

Dimensions

Weight

Electrical Details

Height x Width x Depth

Power Supply

Running Current

Starting Current

Max Fuse Size

Interconnection Wiring Core / Cable size

Piping Connections Liquid / Gas

Pipework Maximum Length

Maximum Vertical Rise

Sound Pressure

Sound Power

Precharged to

Additional Charge

Holding Charge

High mm kg

A

A

A inches m m m g/m kg dBA dBA

ECA Eligible

Trade Fan Coil Price

Trade Condensing Unit Price

Total System Price

FTXG20LW

A++

2.10

4.60

639

4.59 / 5

A / A

250

8.8 / 4.4

2.25

1.84

2.00

2.50

A+++

2.30

8.52

94

12

38 / 25

54

RXG20L

2.70

2.8

16

1/4 / 3/8

20

15

10

1.05

46

61

Matt Crystal White

FTXG25LW FTXG35LW

2.35

1.88

2.50

3.40

A+++

2.40

8.50

99

A++

2.70

4.60

821

4.59 / 4.42

A / A

261

8.8 / 4.4

A++

3.00

4.60

913

3.97 / 4.06

A / A

441

11 / 4.8

3.42

2.51

3.50

4.00

A++

3.50

7.00

175

303

998

212

12

38 / 25

54

12

45 / 26

59

RXG25L

550 x 765 x 285

35

1ph

2.80

4.4

16

3+E / 1.5

1/4 / 3/8

20

15

10

20

1.05

46

61

RXG35L

4.80

5.5

16

1/4 / 3/8

20

15

10

1.05

48

63

● ● ●

12

45 / 35

60

RXG50L

735 x 825 x 300

48

6.20

7.4

20

3+E / 2.5

1/4 / 1/2

30

20

10

FTXG50LW

A+

4.60

4.24

1519

3.53 / 3.65

A / A

680

11.3 / 6.8

4.69

3.09

5.00

5.80

A++

4.80

6.70

251

1.6

48

63

£262.00

£478.00

£740.00

£276.00

£504.00

£780.00

£310.00

£585.00

£895.00

£409.00

£789.00

£1,198.00

FTXG20LS

A++

2.10

4.60

639

4.59 / 5

A / A

250

8.8 / 4.4

2.25

1.84

2.00

2.50

A+++

2.30

8.52

94

12

38 / 25

54

RXG20L

2.70

2.8

16

1/4 / 3/8

20

15

10

1.05

46

61

FTXG25LS

Silver

FTXG35LS

2.35

1.88

2.50

3.40

A+++

2.40

8.50

99

A++

2.70

4.60

821

4.59 / 4.42

A / A

261

8.8 / 4.4

A++

3.00

4.60

913

3.97 / 4.06

A / A

441

11 / 4.8

3.42

2.51

3.50

4.00

A++

3.50

7.00

175

303

998

212

12

38 / 25

54

12

45 / 26

59

RXG25L

550 x 765 x 285

35

1ph

2.80

4.4

16

3+E / 1.5

1/4 / 3/8

20

15

10

20

1.05

46

61

RXG35L

4.80

5.5

16

1/4 / 3/8

20

15

10

1.05

48

63

● ● ●

£313.00

£478.00

£791.00

£329.00

£504.00

£833.00

£369.00

£585.00

£954.00

12

45 / 35

60

RXG50L

735 x 825 x 300

48

6.20

7.4

20

3+E / 2.5

1/4 / 1/2

30

20

10

FTXG50LS

A+

4.60

4.24

1519

3.53 / 3.65

A / A

680

11.3 / 6.8

4.69

3.09

5.00

5.80

A++

4.80

6.70

251

1.6

48

63

£488.00

£789.00

£1,277.00

Accessories:

Accessory Ref

BRC944

BRCW901A03

BRCW901A08

BRP069A41

KRP413A1S

KRP928A2S

KLIC-DD

RTD-RA

UK.CWB90-2

UK.DT1

UK.CGS

UK.CGM

Description

Optional Wired Remote controller

3m connection cable for BRC944

8m connection cable for BRC944

Wifi adaptor for connection to on-line controller

Adaptor PCB for remote on/off control - constant/pulse contact

Adaptor PCB for interface to Daikin centralised control systems

KNX interface for Split type systems

Adaptor PCB for Modbus connection and/or extended system functions

Condensing unit bracket - up to size 71, max weight 90kg of ODU

Condensate drip tray for use with Split ODU - tray width 800mm

Condensing Unit Guard size 20-35

Condensing Unit Guard size 42-71

Trade Price

£64.00

£17.00

£22.00

£40.00

£75.00

£132.00

£164.00

£151.00

£37.00

£56.00

£214.00

£296.00

Features:

> Designed in Europe, perfect for UK climates, Daikin Emura creates the optimum comfort zone all year round

> It represents a perfect marriage of style and substance, of form and function, of intelligent heating and efficient cooling

> Stylish, low-profile design

> Wireless remote controller with weekly timer: provides a 7-day schedule timer, enabling daily or weekly programming.

Up to 4 actions per day possible

> Night set mode: prevents sudden changes in room temperature by gently adjusting the temperature before the system stops

> Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room

> 2-area intelligent eye: air flow is sent to a zone other than where the occupants are located at that moment

> Presence Sensor switches to energy saving mode if room is unoccupied after 20 mins

> Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting

> Fan speed: 5 fan speeds can be selected, high to super low

> Suitable for multi model applications

> Re-use of existing R22 and R407C piping possible

Notes: i) All fan coil units standard with auto restart after power failure ii) All fan coils supplied as standard with infrared remote controller ARC466A1 iii) Wired controller, KLIC-DI and RTD-RA options cannot be combined iv) Minimum ambient operating temperatures:

RXG

Cooling

-10°C

Heating

-15°C

WI-FI

CONTR

OL

VIA APP

Price List 2015 9

FAQ-C / RZQG

Wall Mounted – Seasonal Smart Inverter

Indoor Units

Capacity

Seasonal Efficiency

(EN14825)

COOLING

UK Total Cooling

UK Sensible Cooling

Nominal Cooling

Nominal Heating kW kW kW kW

Energy Label

Pdesign kW

SEER

Annual Energy Consumption kWh

Energy Label

Pdesign kW

Seasonal Efficiency

(EN14825)

HEATING

Nominal Efficiency

SCOP

Annual Energy Consumption kWh

EER / COP

Energy Label

Air Flow Rate

Annual Energy Consumption kWh

High / Low

Dimensions Height m

3

/min mm

Width

Depth mm mm

Weight kg

Sound Pressure

Sound Power

High / Low dBA dBA

Outdoor Units

Dimensions

Weight

Electrical Details

Height x Width x Depth

Interconnection Wiring

Piping Connections

Pipework

Sound Pressure

Sound Power

Power Supply

Running Current

Starting Current

Max Fuse Size

Core / Cable size

Liquid / Gas

Maximum Length

Maximum Vertical Rise

Precharged to

Additional Charge

Holding Charge

High

A

A

A mm kg inches m m m g/m kg dBA dBA

Single Phase

4.02

2204

3.4 / 3.7

A / A

1000

18 / 14

290

1050

238

13

45 / 40

58

FAQ71C

7.76

5.32

6.80

7.50

A++

6.80

6.51

365

A+

6.33

RZQG71L9V1

990 x 940 x 320

78

1ph

8.17

RZQG100L9V1

1430 x 940 x 320

102

10.75

4

20

4

32

3+E / 1.5

3/8 / 5/8

50

30

30

Refer to Installation Manual

3/8 / 5/8

75

30

30

2.9

48

64

4.0

50

66

4.01

3561

3.62 / 3.61

A / A

1315

26 / 19

340

1200

240

17

49 / 41

62

FAQ100C

10.80

7.44

9.50

10.80

A++

9.50

6.11

544

A+

10.20

ECA Eligible

Trade Fan Coil Price

Trade Condensing Unit Price

Total System Price

Accessories:

Accessory Ref

BRC7EB518

KRP4A53/UK.FB2

RTD-NET/UK.FB2

RTD-10/UK.FB2

RTD-20/UK.FB2

KLIC-DI

KRCS01-4

K.RSS

RS-SE

UK.CWB90-2

UK.CWB140-2

UK.DT2

UK.CGM

UK.CGL

£749.00

£1,191.00

£1,940.00

£808.00

£1,514.00

£2,322.00

Description

Wireless remote controller

Unit/Group adaptor PCB for remote on/off, status indication and temperature setting

Modbus Interface PCB for Sky Air and VRV

Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock

Energy control PCB for Sky Air and VRV

KNX Interface for Sky Air and VRV systems

Remote room mounted temperature sensor

Wireless room mounted temperature sensor and receiver

Service and Configuration Tool for K.RSS

Condensing unit bracket - up to size 71, max weight 90kg of ODU

Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU

Condensate drip tray for use with Sky Air ODU - tray width 1100mm

Condensing Unit Guard size 42-71

Condensing Unit Guard size 100-140 including RXYSQ

3 Phase

4.02

2204

3.4 / 3.7

A / A

1000

18 / 14

290

1050

238

13

45 / 40

58

FAQ71C

7.76

5.32

6.80

7.50

A++

6.80

6.51

365

A+

6.33

RZQG71L8Y1

990 x 940 x 320

80

RZQG100L8Y1

1430 x 940 x 320

101

3ph

3.07

4.04

4

16

4

20

3+E / 1.5

3/8 / 5/8

50

30

30

Refer to Installation Manual

3/8 / 5/8

75

30

30

2.9

48

64

4.0

50

66

4.01

3561

3.62 / 3.61

A / A

1315

26 / 19

340

1200

240

17

49 / 41

62

FAQ100C

10.80

7.44

9.50

10.80

A++

9.50

6.11

544

A+

10.20

Trade Price

£152.00

£92.00

£190.00

£235.00

£251.00

£185.00

£42.00

£89.00

£93.00

£37.00

£46.00

£59.00

£296.00

£354.00

£749.00

£1,227.00

£1,976.00

£808.00

£1,584.00

£2,392.00

Notes: i) All fan coils supplied as standard with

BRC1E52A wired remote controller with

7-day time clock ii) BRC7EB518 Trade price will be reduced by

£76.00 if ordered instead of the BRC1E52A iii) All fan coil units standard with auto restart after power failure iv) Minimum ambient operating temperatures:

RZQG

RZQSG

Cooling

-15°C

-15°C

Heating

-20°C

-15°C

Features:

> Fan speed: 3 fan speeds available on all capacities

> Automatic airflow volume control sets fan speed based on difference between set and room temperatures

> Dry programme: Daikin’s special dry programme reduces humidity in the rooms without variations in internal temperature

> Comms, computer and server room cooling possible with EDP setting (Seasonal Smart)

> Selectable evaporating & condensing temperature for greater operating efficiency and application flexibility (Seasonal Smart)

> DIII net compatibility as standard

> Seasonally Efficient Inverter Technology gives up to 25% better efficiency than inverter technology

> Re-use of existing R22 and R407C piping possible. (See R22 Replacement leaflet)

> Suitable for Twin, Triple and Double Twin applications

10 Residential, Commercial and Industrial

FAQ-C / RZQSG

Wall Mounted – Seasonal Classic Inverter

Indoor Units

Capacity

Seasonal Efficiency

(EN14825)

COOLING

UK Total Cooling

UK Sensible Cooling

Nominal Cooling

Nominal Heating

Energy Label

Pdesign

SEER

Annual Energy Consumption

Energy Label

Pdesign

Seasonal Efficiency

(EN14825)

HEATING

Nominal Efficiency

Air Flow Rate

Annual Energy Consumption

High / Low

Dimensions Height

Width

Depth

Weight

SCOP

Annual Energy Consumption

EER / COP

Energy Label

Sound Pressure

Sound Power

High / Low

Outdoor Units

Dimensions

Weight

Electrical Details

Height x Width x Depth

Power Supply

Running Current

Starting Current

Max Fuse Size

Interconnection Wiring Core / Cable size

Piping Connections Liquid / Gas

Pipework Maximum Length

Maximum Vertical Rise

Sound Pressure

Sound Power

Precharged to

Additional Charge

Holding Charge

High

Trade Fan Coil Price

Trade Condensing Unit Price

Total System Price

kW kW kW kW kW kWh kW kWh

A

A

A mm kg inches m m m g/m kg dBA dBA kWh m

3

/min mm mm mm kg dBA dBA

Single Phase

3.90

2155

3.21 / 3.61

A / A

1059

18 / 14

290

1050

238

13

45 / 40

58

FAQ71C

7.28

4.99

6.80

7.50

A+

6.80

6.05

393

A+

6.00

RZQSG71L3V1

770 x 900 x 320

67

1ph

8.66

4

20

3+E / 1.5

3/8 / 5/8

50

30

30

Refer to Installation Manual

2.75

49

65

RZQSG100L9V1

990 x 940 x 320

81

12.91

4

32

3/8 / 5/8

50

30

30

2.9

53

69

£749.00

£820.00

£1,569.00

4.01

2377

3.01 / 3.41

B / B

1580

26 / 19

340

1200

240

17

49 / 41

62

FAQ100C

10.80

7.44

9.50

10.80

A+

9.50

5.61

592

A+

6.81

£808.00

£1,135.00

£1,943.00

RZQSG100L8Y1

990 x 940 x 320

82

3ph

4.86

4

20

3+E / 1.5

3/8 / 5/8

50

30

30

Refer to Installation Manual

2.9

53

69

£808.00

£1,170.00

£1,978.00

4.01

2377

3.01 / 3.41

B / B

1580

26 / 19

340

1200

240

17

49 / 41

62

3 Phase

FAQ100C

10.80

7.44

9.50

10.80

A+

9.50

5.61

592

A+

6.81

Price List 2015 11

Nexura

Floor Mounted – Inverter

Indoor Units

Capacity

Seasonal Efficiency

(EN14825)

COOLING

UK Total Cooling

UK Sensible Cooling

Nominal Cooling

Nominal Heating

Energy Label

Pdesign

SEER kW kW kW kW kW

Seasonal Efficiency

(EN14825)

HEATING

Nominal Efficiency

Air Flow Rate

Weight

Sound Pressure

Sound Power

Annual Energy Consumption kWh

Energy Label

Pdesign

SCOP kW

Annual Energy Consumption kWh

EER / COP

Energy Label

Annual Energy Consumption kWh

High / Low

Dimensions Height

Width

Depth

High / Low m 3 /min mm mm mm kg dBA dBA

Outdoor Units

Dimensions

Weight

Electrical Details

Height x Width x Depth mm kg

Interconnection Wiring

Piping Connections

Pipework

Sound Pressure

Sound Power

Power Supply

Running Current

Starting Current

Max Fuse Size

Core / Cable size

Liquid / Gas

Maximum Length

Maximum Vertical Rise

Precharged to

Additional Charge

Holding Charge

High

A

A

A inches m m m g/m kg dBA dBA

ECA Eligible

Trade Fan Coil Price

Trade Condensing Unit Price

Total System Price

Accessories:

Accessory Ref

BRC944

BRP089A42

BRCW901A03

BRCW901A08

KRP413A1S

KRP928A2S

KLIC-DD

RTD-RA

BKS028

UK.CWB90-2

UK.DT1

UK.CGS

UK.CGM

Description

Optional Wired Remote controller

Wifi adaptor for on-line controller

3m connection cable for BRC944

8m connection cable for BRC944

Adaptor PCB for remote on/off control - constant/pulse contact

Adaptor PCB for interface to Daikin centralised control systems

KNX interface for Split type systems

Adaptor PCB for Modbus connection and/or extended system functions

Leg for floor-standing installation

Condensing unit bracket - up to size 71, max weight 90kg of ODU

Condensate drip tray for use with Split ODU - tray width 800mm

Condensing Unit Guard size 20-35

Condensing Unit Guard size 42-71

34

2.68

4.4

10

1/4 / 3/8

20

15

10

1.05

46

61

£631.00

£504.00

£1,135.00

FVXG25K

2.44

1.93

2.50

3.40

A++

2.50

6.53

134

A++

2.80

4.65

842

- / -

- / -

-

8.9 / 5.3

600

950

215

22

38 / 26

52

RXG25L

550 x 765 x 300

3+E / 1.5

34

1ph

4.64

5.5

10

1/4 / 3/8

20

15

10

20

1.05

48

63

FVXG35K

3.42

2.37

3.50

4.50

A++

3.50

6.48

189

A+

3.10

4.00

1087

- / -

- / -

-

9.1 / 5.3

600

950

215

22

39 / 27

52

RXG35L

£679.00

£585.00

£1,264.00

Notes:

FVXG50K

4.81

3.17

5.00

5.80

A+

5.00

5.41

324

A+

4.60

4.18

1543

- / -

- / -

-

10.6 / 7.3

600

950

215

22

44 / 36

58

RXG50L

735 x 825 x 315

48

6.04

7.4

20

3+E / 2.5

1/4 / 1/2

30

20

10

1.60

48

63 i) All fan coils supplied as standard with infrared remote controller ARC466AZ ii) All fan coil units standard with auto restart after power failure iii) Wired controller, KLIC-DI and RTD-RA options cannot be combined iv) Minimum ambient operating temperatures:

RXG

£744.00

£789.00

£1,533.00

Cooling

-10°C

Heating

-15°C

Features:

> Radiant Heat panel provides radiator-like warming at the touch of a button

> Energy efficient units: full range A class energy labels

> Wireless remote controller provides a 7-day schedule timer, enabling the user to program the air conditioning daily or weekly, with up to 4 actions per day

> Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room

> Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting

> Extremely quiet in operation: down to 19dBA sound pressure level

> Night set mode: prevents any sudden change in room temperature by gently raising/lowering the temperature before the system stops, so you can sleep more comfortably

WI-FI

CONTR

OL

VIA APP

> Vertical auto swing system automatically makes the louvers move up and down, creating an even distribution of air through the room to ensure a harmonized temperature

> Flexible installation: Can be installed against a wall, recessed or standing on the floor (installation leg required, see accessories list).

Ideal for installation beneath a window

> Suitable for multi model applications

> Re-use of existing R22 and R407 piping possible

12 Residential, Commercial and Industrial

Trade Price

£64.00

£50.00

£17.00

£22.00

£75.00

£132.00

£164.00

£151.00

£393.00

£37.00

£56.00

£214.00

£296.00

FVXS

Floor Mounted – Inverter

Indoor Units

Capacity

Seasonal Efficiency

(EN14825)

COOLING

Seasonal Efficiency

(EN14825)

HEATING

UK Total Cooling

UK Sensible Cooling

Nominal Cooling

Nominal Heating

Energy Label

Pdesign

SEER

Annual Energy Consumption

Energy Label

Pdesign

SCOP

Annual Energy Consumption

EER / COP kW kW kW kW kW kWh kW kWh

Nominal Efficiency

Air Flow Rate

Energy Label

Annual Energy Consumption kWh

High / Low

Dimensions Height

Weight

Sound Pressure

Sound Power

Width

Depth

High / Low

High m 3 /min mm mm mm kg dBA dBA

Outdoor Units

Dimensions

Weight

Electrical Details

Height x Width x Depth

Power Supply

Running Current

Starting Current

Max Fuse Size

Interconnection Wiring Core / Cable size

Piping Connections

Pipework

Sound Pressure

Sound Power

Liquid / Gas

Maximum Length

Maximum Vertical Rise

Precharged to

Additional Charge

Holding Charge

High

High

Trade Fan Coil Price

Trade Condensing Unit Price

Total System Price

mm kg

A

A

A inches m m m g/m kg dBA dBA

FVXS25F

2.44

1.87

2.50

3.40

A+

2.50

5.74

152

A+

2.60

4.56

798

4.39 / 4.42

A / A

285

8.2 / 4.8

600

700

210

14

38 / 26

52

RXS25L3

550 x 765 x 285

34

3.30

3.3

10

1/4 / 3/8

20

15

10

1.0

46

59

£523.00

£476.00

£999.00

3+E / 1.5

FVXS35F

3.42

2.34

3.50

4.50

A+

3.50

5.60

219

A

2.90

3.93

1033

3.43 / 3.78

A / A

510

8.5 / 4.9

600

700

210

14

39 / 27

52

RXS35L3

550 x 765 x 285

34

1ph

4.70

4.3

10

1/4 / 3/8

20

15

10

20

1.2

48

61

£564.00

£552.00

£1,116.00

FVXS50F

4.89

3.21

5.00

5.80

A+

5.00

5.89

297

A

4.20

3.80

1546

3.23 / 3.63

A / A

775

10.7 / 7.8

600

700

210

14

44 / 36

60

RXS50L

735 x 825 x 300

47

6.80

6.8

20

3+E / 2.5

1/4 / 1/2

30

20

10

1.7

48

62

£616.00

£694.00

£1,310.00

Accessories:

Accessory Ref

BRP089A42

KRP413A1S

KRP928A2S

KLIC-DD

RTD-RA

UK.CWB90-2

UK.DT1

UK.CGS

UK.CGM

Description

Wifi adaptor for on-line controller

Adaptor PCB for remote on/off control - constant/pulse contact

Adaptor PCB for interface to Daikin centralised control systems

KNX interface for Split type systems

Adaptor PCB for Modbus connection and/or extended system functions

Condensing unit bracket - up to size 71, max weight 90kg of ODU

Condensate drip tray for use with Split ODU - tray width 800mm

Condensing Unit Guard size 20-35

Condensing Unit Guard size 42-71

Trade Price

£50.00

£75.00

£132.00

£164.00

£151.00

£37.00

£56.00

£214.00

£296.00

Notes: i) All fan coils supplied as standard with infrared remote controller ii) All fan coil units standard with auto restart after power failure iii) Wired controller, KLIC-DI and RTD-RA options cannot be combined iv) Minimum ambient operating temperatures:

RXS

Cooling

-10°C

Heating

-15°C

Features:

> Extremely quiet, energy efficient and can be installed against the wall or recessed

> Wireless remote controller with weekly timer: provides a 7-day schedule timer, enabling daily or weekly programming. Up to 4 actions per day possible

> Night set mode: prevents any sudden change in room temperature by gently raising/lowering the temperature before the system stops

> Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting

> Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room

> Dry programme: Daikin’s special dry programme reduces humidity in the rooms without variations in internal temperature

> Suitable for multi model applications

> Re-use of existing R22 and R407C piping possible

WI-FI

CONTR

OL

VIA APP

Price List 2015 13

FVQ-C / RZQG

Floor Mounted – Seasonal Smart Inverter

Indoor Units

Capacity

Seasonal Efficiency

(EN14825)

COOLING

UK Total Cooling

UK Sensible Cooling

Nominal Cooling

Nominal Heating kW kW kW kW

Energy Label

Pdesign kW

SEER

Annual Energy Consumption kWh

Energy Label

Pdesign kW

Seasonal Efficiency

(EN14825)

HEATING

Nominal Efficiency

SCOP

Annual Energy Consumption kWh

EER / COP

Energy Label

Air Flow Rate

Annual Energy Consumption kWh

High / Low

Dimensions Height m

3

/min mm

Width

Depth mm mm

Weight kg

Sound Pressure

Sound Power

High / Low dBA dBA

Outdoor Units

Dimensions Height x Width x Depth

Weight

Electrical Details Power Supply

Running Current

Starting Current

Max Fuse Size

Interconnection Wiring Core / Cable size

Piping Connections Liquid / Gas

Pipework Maximum Length

Maximum Vertical Rise

Precharged to

Additional Charge

Holding Charge

Sound Pressure

Sound Power

High mm kg

A

A

A inches m m m g/m kg dBA dBA

ECA Eligible

Trade Fan Coil Price

Trade Condensing Unit Price

Total System Price

4.05

2188

3.37 / 3.64

A / A

1010

18 / 14

1850

600

270

39

43 / 38

55

FVQ71C

7.76

5.32

6.80

7.50

A++

6.80

6.31

377

A+

6.33

Single Phase

FVQ100C

10.80

7.44

9.50

10.80

A+

9.50

5.61

592

A+

11.30

4.20

3766

3.81 / 4.14

A / A

1245

28 / 22

1850

600

350

47

50 / 44

62

FVQ125C

13.60

9.30

12.00

13.50

A+

12.00

5.61

748

A

11.30

3.87

4087

3.21 / 3.7

A / A

1870

28 / 24

1850

600

350

47

51 / 46

63

FVQ140C

-

-

-

-

14.90

10.25

13.40

15.50

-

-

-

-

3.21 / 3.61

A / A

2085

30 / 26

1850

600

350

47

53 / 48

65

FVQ71C

7.76

5.32

6.80

7.50

A++

6.80

6.31

377

A+

6.33

4.05

2188

3.37 / 3.64

A / A

1010

18 / 14

1850

600

270

39

43 / 38

55

FVQ100C

10.80

7.44

9.50

10.80

A+

9.50

5.61

592

A+

11.30

4.20

3766

3 Phase

3.81 / 4.14

A / A

1245

28 / 22

1850

600

350

47

50 / 44

62

FVQ125C

13.60

9.30

12.00

13.50

A+

12.00

5.61

748

A

11.30

3.87

4087

3.21 / 3.7

A / A

1870

28 / 24

1850

600

350

47

51 / 46

63

RZQG71L9V1 RZQG100L9V1 RZQG125L9V1 RZQG140L9V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1

990 x 940 x 320

78

1430 x 940 x 320

102

1430 x 940 x 320

102

1430 x 940 x 320

102

990 x 940 x 320

80

1430 x 940 x 320

101

1430 x 940 x 320

101

1430 x 940 x 320

101

8.26

4

20

3/8 / 5/8

50

30

30

2.9

48

64

1ph

10.18

4

32

15.29

4

32

3+E / 1.5

3/8 / 5/8 3/8 / 5/8

75

30

75

30

30 30

Refer to Installation Manual

4.0

4.0

50

66

51

67

17.04

4

32

3/8 / 5/8

75

30

30

4.0

52

69

3.11

4

16

3/8 / 5/8

50

30

30

2.9

48

64

3.83

4

20

3+E / 1.5

3/8 / 5/8 3/8 / 5/8

75

30

75

30

30 30

Refer to Installation Manual

4.0

50

66

3ph

5.75

4

20

4.0

51

67

6.41

4

20

3/8 / 5/8

75

30

30

4.0

52

69

-

-

3.21 / 3.61

A / A

2085

30 / 26

1850

600

350

47

53 / 48

65

FVQ140C

-

-

-

-

14.90

10.25

13.40

15.50

-

-

£999.00

£1,191.00

£2,190.00

£1,098.00

£1,514.00

£2,612.00

£1,211.00

£1,666.00

£2,877.00

£1,302.00

£1,901.00

£3,203.00

£999.00

£1,227.00

£2,226.00

£1,098.00

£1,584.00

£2,682.00

£1,211.00

£1,743.00

£2,954.00

£1,302.00

£2,002.00

£3,304.00

Accessories:

Accessory Ref

KRP4A53/UK.FB2

RTD-NET/UK.FB2

RTD-10/UK.FB2

RTD-20/UK.FB2

KLIC-DI

UK.CWB90-2

UK.CWB140-2

UK.DT2

UK.CGM

UK.CGL

Description

Unit/Group adaptor PCB for remote on/off, status indication and temperature setting

Modbus Interface PCB for Sky Air and VRV

Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock

Energy control PCB for Sky Air and VRV

KNX Interface for Sky Air and VRV systems

Condensing unit bracket - up to size 71, max weight 90kg of ODU

Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU

Condensate drip tray for use with Sky Air ODU - tray width 1100mm

Condensing Unit Guard size 42-71

Condensing Unit Guard size 100-140 including RXYSQ

Trade Price

£92.00

£190.00

£235.00

£251.00

£185.00

£37.00

£46.00

£59.00

£296.00

£354.00

Notes: i) All fan coils supplied as standard with

BRC1E52A wired remote controller with

7-day time clock ii) All fan coil units standard with auto restart after power failure iii) Minimum ambient operating temperatures:

RZQG

RZQSG

Cooling

-15°C

-15°C

Heating

-20°C

-15°C

Features:

> Seasonally Efficient Inverter Technology gives up to 25% better efficiency than Inverter Technology

> Vertical air flow pattern can be adjusted manually to match requirements in different sized interiors or irregularly shaped rooms

> A wired BRC1E52A remote controller is mounted on the front of the unit (standard)

> Controllable horizontal air-blow patterns, via remote control

> Very efficient for use in rooms with high ceilings

> Fan speed: 2 fan speeds can be selected, high or low

> Re-use of existing R22 and R407C piping possible

> Comms, computer and server room cooling possible with EDP setting (Seasonal Smart)

> Selectable evaporating & condensing temperature for greater operating efficiency (Seasonal Smart)

> DIII net compatibility as standard

14 Residential, Commercial and Industrial

FVQ-C / RZQSG

Floor Mounted – Seasonal Classic Inverter

Indoor Units

Capacity

Seasonal Efficiency

(EN14825)

COOLING

UK Total Cooling

UK Sensible Cooling

Nominal Cooling

Nominal Heating

Energy Label

Pdesign

SEER

Annual Energy Consumption

Energy Label

Pdesign kW kW kW kW kW kWh

Seasonal Efficiency

(EN14825)

HEATING kW

Nominal Efficiency

SCOP

Annual Energy Consumption

EER / COP

Energy Label kWh

Air Flow Rate

Annual Energy Consumption kWh

High / Low

Dimensions Height m

3

/min mm

Width

Depth mm mm

Weight kg

Sound Pressure

Sound Power

High / Low dBA dBA

Outdoor Units

Dimensions

Weight

Electrical Details

Height x Width x Depth

Power Supply

Running Current

Starting Current

Max Fuse Size

Interconnection Wiring Core / Cable size

Piping Connections Liquid / Gas

Pipework Maximum Length

Maximum Vertical Rise

Sound Pressure

Sound Power

Precharged to

Additional Charge

Holding Charge

High

Trade Fan Coil Price

Trade Condensing Unit Price

Total System Price

A

A

A mm kg inches m m m g/m kg dBA dBA

3.86

2296

3.21 / 3.61

A / A

1059

18 / 14

1850

600

270

39

43 / 38

53

FVQ71C

7.28

4.99

6.80

7.50

A

6.80

5.50

433

A

6.33

4.01

2653

3.21 / 3.61

A / A

1480

28 / 22

1850

600

350

47

50 / 44

59

Single Phase

FVQ100C FVQ125C

10.80

7.44

9.50

10.80

A

9.50

5.50

604

A+

7.60

13.60

9.30

12.00

13.50

A

12.00

5.50

763

A

7.60

3.85

2763

2.81 / 3.41

C / B

2135

28 / 24

1850

600

350

47

51 / 46

60

-

-

3.01 / 3.41

B / B

2225

30 / 26

1850

600

350

47

53 / 48

63

FVQ140C

-

-

-

-

14.90

10.25

13.40

15.50

-

-

4.01

2653

3.21 / 3.61

A / A

1480

28 / 22

1850

600

350

47

50 / 44

59

FVQ100C

10.80

7.44

9.50

10.80

A

9.50

5.50

377

A+

7.60

3.85

2763

2.81 / 3.41

C / B

2135

28 / 24

1850

600

350

47

51 / 46

60

3 Phase

FVQ125C

13.60

9.30

12.00

13.50

A

12.00

5.50

604

A

7.60

RZQSG71L3V1 RZQSG100L9V1 RZQSG125L9V1 RZQSG140L9V1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1

770 x 900 x 320 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320

67

8.66

12.10

81

1ph

17.45

102

18.19

4.55

82

3ph

6.56

101

6.84

4

20

4

32

3/8 / 5/8

50

30

30

2.75

49

65

4

32

4

32

3/8 / 5/8

3+E / 1.5

3/8 / 5/8

50

30

50

30

30 30

Refer to Installation Manual

2.9

53

69

2.9

54

70

3/8 / 5/8

50

30

30

4.0

53

69

4

20

4

20

3+E / 1.5

3/8 / 5/8

4

20

3/8 / 5/8

50

30

30

50

30

30

Refer to Installation Manual

3/8 / 5/8

50

30

30

2.9

53

69

2.9

54

70

4.0

53

69

£999.00

£820.00

£1,819.00

£1,098.00

£1,135.00

£2,233.00

£1,211.00

£1,245.00

£2,456.00

£1,302.00

£1,386.00

£2,688.00

£1,098.00

£1,170.00

£2,268.00

£1,211.00

£1,282.00

£2,493.00

£1,302.00

£1,428.00

£2,730.00

-

-

3.01 / 3.41

B / B

2225

30 / 26

1850

600

350

47

53 / 48

63

FVQ140C

-

-

-

-

14.90

10.25

13.40

15.50

-

-

Price List 2015 15

FLXS

Floor or Ceiling Mounted – Inverter

Indoor Units

Capacity UK Total Cooling

UK Sensible Cooling kW kW

Seasonal Efficiency

(EN14825)

COOLING

Seasonal Efficiency

(EN14825)

HEATING

Nominal Cooling

Nominal Heating

Energy Label

Pdesign kW kW kW

SEER

Annual Energy Consumption kWh

Energy Label

Pdesign kW

SCOP

Annual Energy Consumption kWh

EER / COP Nominal Efficiency

Air Flow Rate

Sound Power

Energy Label

Annual Energy Consumption kWh

High / Low

Dimensions Height

Weight

Sound Pressure

Width

Depth

High / Low m 3 /min mm mm mm kg dBA dBA

Outdoor Units

Dimensions

Weight

Electrical Details

Height x Width x Depth

Interconnection Wiring

Piping Connections

Pipework

Sound Pressure

Sound Power

Trade Fan Coil Price

Trade Condensing Unit Price

Total System Price

Power Supply

Running Current

Starting Current

Max Fuse Size

Core / Cable size

Liquid / Gas

Maximum Length

Maximum Vertical Rise

Precharged to

Additional Charge

Holding Charge

High mm kg

A

A

A inches m m m g/m kg dBA dBA

FLXS25B

2.44

1.65

2.50

3.40

A

2.50

5.19

169

A

2.50

3.80

921

3.85 / 3.54

A / B

325

7.6 / 6

490

1050

200

16

37 / 31

51

RXS25L3

550 x 765 x 285

34

3.60

3.3

10

1/4 / 3/8

20

15

10

1.0

46

59

£376.00

£476.00

£852.00

3+E / 1.5

FLXS35B9

3.34

2.14

3.50

4.00

B

3.50

4.87

252

A

2.90

3.80

1068

3.1 / 3.57

B / B

565

8.6 / 6.6

490

1050

200

16

38 / 32

53

RXS35L3

550 x 765 x 285

34

1ph

5.10

4.3

10

1/4 / 3/8

20

15

10

20

1.2

48

61

£423.00

£552.00

£975.00

FLXS50B

4.82

3.16

4.90

6.10

A

4.90

5.25

326

A

4.20

3.80

1546

2.85 / 3.35

C / C

860

11.4 / 8.5

490

1050

200

17

47 / 39

60

RXS50L

735 x 825 x 300

47

7.60

6.8

20

3+E / 2.5

1/4 / 1/2

30

20

10

1.7

48

62

£459.00

£694.00

£1,153.00

Accessories:

Accessory Ref

KRP413A1S

KRP928A2S

KLIC-DD

RTD-RA

UK.CWB90-2

UK.DT1

UK.CGS

UK.CGM

Description

Adaptor PCB for remote on/off control - constant/pulse contact

Adaptor PCB for interface to Daikin centralised control systems

KNX interface for Split type systems

Adaptor PCB for Modbus connection and/or extended system functions

Condensing unit bracket - up to size 71, max weight 90kg of ODU

Condensate drip tray for use with Split ODU - tray width 800mm

Condensing Unit Guard size 20-35

Condensing Unit Guard size 42-71

Trade Price

£75.00

£132.00

£164.00

£151.00

£37.00

£56.00

£214.00

£296.00

Notes: i) All fan coils supplied as standard with infrared remote controller ii) Wired controller, KLIC-DI and RTD-RA options cannot be combined iii) All fan coil units standard with auto restart after power failure iv) Minimum ambient operating temperatures:

RXS

Cooling

-10°C

Features:

> Can be installed EITHER as ceiling mounted OR wall unit

> Vertical auto swing: flaps automatically swing up and down to ensure efficient air and temperature distribution in both floor level and ceiling suspended installation

> Home Leave setting maintains pre-set temperature during periods of extended absence

> Night set mode: prevents any sudden change in room temperature by gently raising/lowering the temperature before the system stops

> Fan speed: 5 fan speeds can be selected, high to super low

> Suitable for multi model applications

> Re-use of existing R22 and R407C piping possible

Heating

-15°C

16 Residential, Commercial and Industrial

FHQ-C

Ceiling Suspended – Inverter

Indoor Units

Capacity

Seasonal Efficiency

(EN14825)

COOLING

Seasonal Efficiency

(EN14825)

HEATING

UK Total Cooling

UK Sensible Cooling

Nominal Cooling

Nominal Heating

Energy Label

Pdesign

SEER

Annual Energy Consumption

Energy Label

Pdesign

SCOP

Annual Energy Consumption

EER / COP kW kW kW kW kW kWh kW kWh

Nominal Efficiency

Air Flow Rate

Sound Power

Energy Label

Annual Energy Consumption kWh

High / Low

Dimensions Height

Weight

Sound Pressure

Width

Depth

High / Low m 3 /min mm mm mm kg dBA dBA

Outdoor Units

Dimensions

Weight

Electrical Details

Height x Width x Depth

Power Supply

Running Current

Starting Current

Max Fuse Size

Interconnection Wiring Core / Cable size

Piping Connections

Pipework

Sound Pressure

Sound Power

Liquid / Gas

Maximum Length

Maximum Vertical Rise

Precharged to

Additional Charge

Holding Charge

High mm kg

A

A

A inches m m m g/m kg dBA dBA

ECA Eligible

Trade Fan Coil Price

Trade Condensing Unit Price

Total System Price

RXS35L3

550 x 765 x 285

34

4.1

4.3

10

3+E / 1.5

1/4 / 3/8

20

15

10

1.2

48

61

FHQ35C

3.32

2.58

3.40

4.00

A++

3.40

6.18

193

A+

3.10

4.43

981

3.58 / 4.08

A / A

475

14 / 10

235

960

690

24

36 / 31

53

£666.00

£552.00

£1,218.00

Accessories:

Accessory Ref

BRC7G53

EKRORO4

KRP4A53/UK.FB2

RTD-NET/UK.FB2

RTD-10/UK.FB2

RTD-20/UK.FB2

KLIC-DI

KRCS01-4

K.RSS

RS-SE

UK.CWB90-2

UK.DT1

UK.CGS

UK.CGM

KDDQ50A140

Description

Wireless remote controller

Remote on/off control interface kit

Unit/Group adaptor PCB for remote on/off, status indication and temperature setting

Modbus Interface PCB for Sky Air and VRV

Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock.

Energy control PCB for Sky Air and VRV.

KNX Interface for Sky Air and VRV systems

Remote room mounted temperature sensor

Wireless room mounted temperature sensor and receiver

Service and Configuration Tool for K.RSS

Condensing unit bracket - up to size 71, max weight 90kg of ODU

Condensate drip tray for use with Split ODU - tray width 800mm

Condensing Unit Guard size 20-35

Condensing Unit Guard size 42-71

Fresh air intake kit for up to 20% fresh air

FHQ50C

4.92

3.52

5.00

6.00

A+

5.00

5.87

298

A

4.35

3.86

1578

3.18 / 3.35

B / C

785

15 / 10

235

960

690

25

37 / 32

54

RXS50L

735 x 825 x 300

47

1ph

7.3

6.8

20

1/4 / 1/2

30

20

10

20.0

1.7

48

62

£722.00

£694.00

£1,416.00

Trade Price

£152.00

£29.00

£92.00

£190.00

£235.00

£251.00

£185.00

£42.00

£89.00

£93.00

£37.00

£56.00

£214.00

£296.00

£158.00

3+E / 2.5

Features:

> Suitable for ceiling heights of up to 3.8m without loss of capacity

> Vertical auto-swing function of flaps ensures efficient air and temperature distribution

> Forced off: The optional forced off feature enables the unit to switch off automatically, for example when a window is opened

> Re-use of existing R22 and R407C piping possible

> Suitable for Twin, Triple and Double Twin applications

£792.00

£740.00

£1,532.00

Notes: i) All fan coils supplied as standard with

BRC1E52A wired remote controller with

7-day time clock ii) BRC7GA53 Trade price will be reduced by £76.00 if ordered in place of the

BRC1E52A iii) All fan coil units standard with auto restart after power failure iv) Minimum ambient operating temperatures:

RXS

Cooling

-10°C

Heating

-15°C

FHQ60C

5.57

3.93

5.70

7.20

A+

5.70

6.02

332

A

4.71

3.87

1705

3.26 / 3.32

A / C

875

19.5 / 15

235

1270

690

31

37 / 33

54

RXS60L

735 x 825 x 300

48

7.8

9.4

20

1/4 / 1/2

30

20

10

1.5

49

62

Price List 2015 17

Accessories:

Accessory Ref

BRC7G53

EKRORO4

KRP4A53/UK.FB2

RTD-NET/UK.FB2

RTD-10/UK.FB2

RTD-20/UK.FB2

KLIC-DI

KRCS01-4

K.RSS

RS-SE

UK.CWB90-2

UK.CWB140-2

UK.DT2

UK.CGS

UK.CGM

UK.CGL

KDDQ50A140

FHQ-C / RZQG

Ceiling Suspended – Seasonal Smart Inverter

Indoor Units

Capacity

Seasonal Efficiency

(EN14825)

COOLING

UK Total Cooling

UK Sensible Cooling

Nominal Cooling

Nominal Heating kW kW kW kW

Energy Label

Pdesign kW

SEER

Annual Energy Consumption kWh

Energy Label

Pdesign kW

Seasonal Efficiency

(EN14825)

HEATING

Nominal Efficiency

SCOP

Annual Energy Consumption kWh

EER / COP

Energy Label

Air Flow Rate

Annual Energy Consumption kWh

High / Low

Dimensions Height m

3

/min mm

Width

Depth mm mm

Weight kg

Sound Pressure

Sound Power

High / Low dBA dBA

Outdoor Units

Dimensions

Weight

Electrical Details

Height x Width x Depth

Starting Current

Max Fuse Size

Interconnection Wiring Core / Cable size

Piping Connections Liquid / Gas

Pipework Maximum Length

Maximum Vertical Rise

Sound Pressure

Precharged to

Additional Charge

Holding Charge

High

Sound Power

Power Supply

Running Current mm kg

A

A

A inches m m m g/m kg dBA dBA

ECA Eligible

Trade Fan Coil Price

Trade Condensing Unit Price

Total System Price

4.32

2462

3.82 / 4.13

A / A

890

20.5 / 14

235

1270

690

32

38 / 34

53

FHQ71C

7.76

5.32

6.80

7.50

A++

6.80

6.95

342

A+

7.60

Single Phase

FHQ100C

10.80

7.44

9.50

10.80

A++

9.50

6.11

544

A++

11.30

4.61

3431

4.13 / 4.42

A / A

1245

28 / 20

235

1590

690

38

42 / 34

56

FHQ125C

13.60

9.30

12.00

13.50

A+

12.00

6.01

698

A+

14.13

4.23

4676

3.52 / 3.89

A / A

1790

31 / 23

235

1590

690

38

44 / 37

59

FHQ140C

-

-

-

-

14.90

10.25

13.40

15.50

-

-

-

-

3.31 / 3.63

A / A

2025

34 / 24

235

1590

690

38

46 / 38

60

FHQ71C

7.76

5.32

6.80

7.50

A++

6.80

6.95

342

A+

7.60

4.32

2462

3.82 / 4.13

A / A

890

20.5 / 14

235

1270

690

32

38 / 34

53

FHQ100C

10.80

7.44

9.50

10.80

A++

9.50

6.11

544

A++

11.30

4.61

3431

3 Phase

4.13 / 4.42

A / A

1245

28 / 20

235

1590

690

38

42 / 34

56

FHQ125C

13.60

9.30

12.00

13.50

A+

12.00

6.01

698

A+

14.13

4.23

4676

3.52 / 3.89

A / A

1790

31 / 23

235

1590

690

38

44 / 37

59

RZQG71L9V1 RZQG100L9V1 RZQG125L9V1 RZQG140L9V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1

990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320

78 102 80 101

1ph 3ph

7.27

10.18

14.63

16.55

2.74

3.83

5.50

6.23

4

20

4

32

4

16

4

20

3/8 / 5/8

50

30

30

2.9

48

64

4

32

4

32

3+E / 1.5

3/8 / 5/8 3/8 / 5/8

75

30

75

30

30 30

Refer to Installation Manual

4.0

50

4.0

51

66 67

3/8 / 5/8

75

30

30

4.0

52

69

3/8 / 5/8

50

30

30

2.9

48

64

4

20

4

20

3+E / 1.5

3/8 / 5/8 3/8 / 5/8

75

30

75

30

30 30

Refer to Installation Manual

4.0

50

4.0

51

66 67

3/8 / 5/8

75

30

30

4.0

52

69

-

-

3.31 / 3.63

A / A

2025

34 / 24

235

1590

690

38

46 / 38

60

FHQ140C

-

-

-

-

14.90

10.25

13.40

15.50

-

-

£926.00

£1,191.00

£2,117.00

£983.00

£1,514.00

£2,497.00

£1,229.00

£1,666.00

£2,895.00

£1,459.00

£1,901.00

£3,360.00

£926.00

£1,227.00

£2,153.00

£983.00

£1,584.00

£2,567.00

£1,229.00

£1,743.00

£2,972.00

£1,459.00

£2,002.00

£3,461.00

Description

Wireless remote controller

Remote on/off control interface kit

Unit/Group adaptor PCB for remote on/off, status indication and temperature setting

Modbus Interface PCB for Sky Air and VRV

Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock

Energy control PCB for Sky Air and VRV

KNX Interface for Sky Air and VRV systems

Remote room mounted temperature sensor

Wireless room mounted temperature sensor and receiver

Service and Configuration Tool for K.RSS

Condensing unit bracket - up to size 71, max weight 90kg of ODU

Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU

Condensate drip tray for use with Sky Air ODU - tray width 1100mm

Condensing Unit Guard size 20-35

Condensing Unit Guard size 42-71

Condensing Unit Guard size 100-140 including RXYSQ

Fresh air intake kit for up to 20% fresh air

Trade Price

£152.00

£29.00

£92.00

£190.00

£235.00

£251.00

£185.00

£42.00

£89.00

£93.00

£37.00

£46.00

£59.00

£214.00

£296.00

£354.00

£158.00

Notes: i) All fan coils supplied as standard with

BRC1E52A wired remote controller with

7-day time clock ii) BRC7GA53 Trade price will be reduced by £76.00 if ordered in place of the

BRC1E52A iii) All fan coil units standard with auto restart after power failure iv) Minimum ambient operating temperatures:

RZQG

RZQSG

Cooling

-15°C

-15°C

Heating

-20°C

-15°C

Features:

> Suitable for ceiling heights of up to 3.8m without loss of capacity

> Seasonally Efficient Inverter Technology gives up to 25% better efficiency than inverter technology

> Forced off: The optional forced off enables the unit to switch off automatically, for example when a window is opened

> Re-use of existing R22 and R407C piping possible

> Suitable for Twin, Triple and Double Twin applications

> Comms, computer and server room cooling possible with EDP setting (Seasonal Smart)

> Selectable evaporating & condensing temperature for greater operating efficiency (Seasonal Smart)

> DIII net compatibility as standard

18 Residential, Commercial and Industrial

FHQ-C / RZQSG

Ceiling Suspended – Seasonal Classic Inverter

Indoor Units

Capacity

Seasonal Efficiency

(EN14825)

COOLING

UK Total Cooling

UK Sensible Cooling

Nominal Cooling

Nominal Heating

Energy Label

Pdesign

SEER

Annual Energy Consumption

Energy Label

Pdesign kW kW kW kW kW kWh

Seasonal Efficiency

(EN14825)

HEATING kW

Nominal Efficiency

SCOP

Annual Energy Consumption

EER / COP

Energy Label kWh

Air Flow Rate

Annual Energy Consumption kWh

High / Low

Dimensions Height m

3

/min mm

Width

Depth mm mm

Weight kg

Sound Pressure

Sound Power

High / Low dBA dBA

Outdoor Units

Dimensions

Weight

Electrical Details

Height x Width x Depth

Power Supply

Running Current

Starting Current

Max Fuse Size

Interconnection Wiring Core / Cable size

Piping Connections Liquid / Gas

Pipework Maximum Length

Maximum Vertical Rise

Sound Pressure

Sound Power

Precharged to

Additional Charge

Holding Charge

High

Trade Fan Coil Price

Trade Condensing Unit Price

Total System Price

A

A

A mm kg inches m m m g/m kg dBA dBA

3.90

2727

3.46 / 4

A / A

983

20.5 / 14

235

1270

690

32

38 / 34

53

FHQ71C

7.28

4.99

6.80

7.50

A+

6.80

5.61

424

A

7.60

3.91

2721

3.21 / 3.61

A / A

1480

28 / 20

235

1590

690

38

42 / 34

56

Single Phase

FHQ100C FHQ125C

10.80

7.44

9.50

10.80

A+

9.50

5.61

592

A

7.60

13.60

9.30

12.00

13.50

A+

12.00

5.61

748

A+

7.60

4.01

2653

2.89 / 3.62

C / A

2075

31 / 23

235

1590

690

38

44 / 37

59

-

-

3.01 / 3.41

B / B

2225

34 / 24

235

1590

690

38

46 / 38

60

FHQ140C

-

-

-

-

14.90

10.25

13.40

15.50

-

-

3.91

2721

3.21 / 3.61

A / A

1480

28 / 20

235

1590

690

38

42 / 34

56

FHQ100C

10.80

7.44

9.50

10.80

A+

9.50

5.61

592

A

7.60

4.01

2653

2.89 / 3.62

C / A

2075

31 / 23

235

1590

690

38

44 / 37

59

3 Phase

FHQ125C

13.60

9.30

12.00

13.50

A+

12.00

5.61

748

A+

7.60

RZQSG71L3V1 RZQSG100L9V1 RZQSG125L9V1 RZQSG140L9V1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1

770 x 900 x 320 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320

67

8.05

12.10

81

1ph

16.96

102

18.19

4.52

82

3ph

6.34

101

6.80

4

20

4

32

3/8 / 5/8

50

30

30

2.75

49

65

4

32

4

32

3/8 / 5/8

3+E / 1.5

3/8 / 5/8

50

30

50

30

30 30

Refer to Installation Manual

2.9

53

69

2.9

54

70

3/8 / 5/8

50

30

30

4.0

53

69

4

20

4

20

3+E / 1.5

3/8 / 5/8

4

20

3/8 / 5/8

50

30

30

50

30

30

Refer to Installation Manual

3/8 / 5/8

50

30

30

2.9

53

69

2.9

54

70

4.0

53

69

£926.00

£820.00

£1,746.00

£983.00

£1,135.00

£2,118.00

£1,229.00

£1,245.00

£2,474.00

£1,459.00

£1,386.00

£2,845.00

£983.00

£1,170.00

£2,153.00

£1,229.00

£1,282.00

£2,511.00

£1,459.00

£1,428.00

£2,887.00

-

-

3.01 / 3.41

B / B

2225

34 / 24

235

1590

690

38

46 / 38

60

FHQ140C

-

-

-

-

14.90

10.25

13.40

15.50

-

-

Price List 2015 19

AHQ-C / AZQS

Ceiling Suspended – Inverter

Indoor Units

Capacity

Seasonal Efficiency

(EN14825)

COOLING

Seasonal Efficiency

(EN14825)

HEATING

Nominal Efficiency

Air Flow Rate

Dimensions

Weight

Sound Pressure

Sound Power

UK Total Cooling

UK Sensible Cooling

Nominal Cooling

Nominal Heating kW kW kW kW

Energy Label

Pdesign kW

SEER

Annual Energy Consumption kWh

Energy Label

Pdesign kW

SCOP

Annual Energy Consumption kWh

EER / COP

Energy Label

Annual Energy Consumption kWh

High / Low m

3

/min

Height

Width

Depth mm mm mm kg

High / Low dBA dBA

Outdoor Units

Dimensions

Weight

Electrical Details

Height x Width x Depth

Power Supply

Running Current

Starting Current

Max Fuse Size

Interconnection Wiring Core / Cable size

Piping Connections

Pipework

Liquid / Gas

Maximum Length

Sound Pressure

Sound Power

Maximum Vertical Rise

Precharged to

Additional Charge

Holding Charge

High mm kg

A

A

A inches m m m g/m kg dBA dBA

3.80

2332

3.03 / 3.05

B / D

1120

23.8 / 18.9

260

1320

634

38

49 / 46

52

AHQ71C

7.28

4.99

6.80

7.50

B

6.80

4.65

511

A

6.33

AHQ100C

10.80

7.44

9.50

10.80

B

9.50

4.60

723

A

7.60

3.80

2800

2.62 / 3.41

D / B

1810

31.1 / 24.8

260

1538

634

45

51 / 45

73

Single Phase

AHQ125C

13.60

9.30

12.10

13.50

-

-

-

-

-

-

-

-

2.63 / 3.61

D / A

2300

34.4 / 27.2

260

1786

634

54

52 / 47

73

AHQ140C

-

-

-

-

14.90

10.25

13.00

15.50

-

-

-

-

3.01 / 3.41

B / B

2159

43.9 / 28.3

285

1902

680

70

53 / 47

75

AHQ100C

10.80

7.44

9.50

10.80

B

9.50

4.60

723

A

7.60

3.80

2800

2.62 / 3.41

D / B

1810

31.1 / 24.8

260

1538

634

45

51 / 45

73.00

AZQS71BV1 AZQS100B8V1 AZQS125B8V1 AZQS140B8V1 AZQS100BY1 AZQS125BY1

770x900x320

67

9.07

4

1~ / 50 / 220 - 240

14.79

18.80

4

990x940x320

81

4

1430x940x320

102

17.66

4

4.92

4

990x940x320

81

3~ / 50 / 400

6.25

4

20

3/8 / 5/8

30

15

30 data-book

48

64

32 32

3/8 / 5/8

3+E / 1.5

3/8 / 5/8

30

15

30

30

15

30 data-book data-book data-book

53

70

54

71

32

3/8 / 5/8

30

15

30 data-book

53

70

20

3/8 / 5/8

30

15

30 data-book

53

70

20

3+E / 1.5

3/8 / 5/8

30

15

30 data-book data-book

54

71

-

-

2.63 / 3.61

D / A

2300

34.4 / 27.2

260

1786

634

54

52 / 47

73.00

3 Phase

AHQ125C

-

-

-

-

13.60

9.30

12.10

13.50

-

-

Trade Fan Coil Price

Trade Condensing Unit Price

Total System Price

£625.00

£714.00

£1,339.00

£756.00

£878.00

£1,634.00

£950.00

£986.00

£1,936.00

£1,098.00

£1,104.00

£2,202.00

£756.00

£926.00

£1,682.00

£950.00

£1,038.00

£1,988.00

-

-

3.01 / 3.41

B / B

2159

43.9 / 28.3

285

1902

680

70

53 / 47

75.00

AHQ140C

-

-

-

-

14.90

10.25

13.00

15.50

-

-

AZQS140BY1

1430x940x320

101

5.87

4

20

3/8 / 5/8

30

15

30 data-book

53

70

£1,098.00

£1,164.00

£2,262.00

Accessories:

Accessory Ref

R04084124324

UK.CWB90-2

UK.CWB140-2

UK.DT1

UK.DT2

UK.CGM

UK.CGL

Description

PCB Adaptor for group control (1 per fan-coil)

Condensing unit bracket - up to size 71

Condensing unit bracket - sizes 100 to 140

Condensate drip tray for use with UK.CWB90-2

Condensate drip tray for use with UK.CWB140-2

Condensing Unit Guard size 42-71

Condensing Unit Guard size 100-140 including RXYSQ

Features:

> Hard wired remote ARCWB as standard

> Long airflow

> 3 step fan speed and auto mode

> Turbo mode to quickly heat / cool room

> Ideal for rooms with solid or high ceilings

Trade Price

£82.00

£36.00

£46.00

£54.00

£59.00

£296.00

£354.00

Notes: i) Fan-coils supplied with both ARCWB hard wired remote & infra-red remote ii) Replacement Technology not applicable to AZQS iii) All fan coil units standard with auto restart after power failure iv) Minimum ambient operating temperature:

AZQS

Cooling

-5°C

Heating

-15°C

20 Residential, Commercial and Industrial

FUQ-C / RZQG

Under Ceiling Cassette – Seasonal Smart Inverter

Indoor Units

Capacity

Seasonal Efficiency

(EN14825)

COOLING

Seasonal Efficiency

(EN14825)

HEATING

Nominal Efficiency

Air Flow Rate

Dimensions

Weight

Sound Pressure

Sound Power

UK Total Cooling

UK Sensible Cooling

Nominal Cooling

Nominal Heating

Energy Label

Pdesign

SEER

Annual Energy Consumption

Energy Label

Pdesign

SCOP

Annual Energy Consumption

EER / COP

Energy Label

Annual Energy Consumption

High / Low

Height

Width

Depth

High / Low kW kW kW kW kW kWh kW kWh kWh m

3

/min mm mm mm kg dBA dBA

FUQ71C

7.76

5.32

6.80

7.50

A++

6.80

6.50

366

A+

7.60

4.20

2533

4.07 / 4.47

A / A

840

23 / 16

198

950

950

25

41 / 35

59

Single Phase

FUQ100C

10.80

7.44

9.50

10.80

A++

9.50

6.11

544

A+

11.30

4.50

3517

4.08 / 4.04

A / A

1230

31 / 20

198

950

950

26

46 / 39

64

FUQ125C

13.60

9.30

12.00

13.50

A+

12.00

5.61

748

A+

14.13

4.44

4456

3.4 / 4.04

A / A

1770

32.5 / 20.5

198

950

950

26

47 / 40

65

FUQ71C

7.76

5.32

6.80

7.50

A++

6.80

6.50

366

A+

7.60

4.20

2533

4.07 / 4.47

A / A

840

23 / 16

198

950

950

25

41 / 35

59

Outdoor Units

Dimensions

Weight

Electrical Details

Height x Width x Depth

Power Supply

Running Current

Starting Current

Max Fuse Size

Interconnection Wiring Core / Cable size

Piping Connections Liquid / Gas

Pipework Maximum Length

Maximum Vertical Rise

Sound Pressure

Sound Power

Precharged to

Additional Charge

Holding Charge

High

A

A

A mm kg inches m m m g/m kg dBA dBA

RZQG71L9V1

990 x 940 x 320

78

6.83

4

20

3/8 / 5/8

50

30

30

2.9

48

64

RZQG100L9V1 RZQG125L9V1

1430 x 940 x 320

102

1ph

9.52

4

32

14.06

4

32

3+E / 1.5

3/8 / 5/8

75

30

30

Refer to Installation Manual

4.0

50

66

3/8 / 5/8

75

30

30

4.0

51

67

3 Phase

FUQ100C

10.80

7.44

9.50

10.80

A++

9.50

6.11

544

A+

11.30

4.50

3515

4.08 / 4.04

A / A

1230

31 / 20

198

950

950

26

46 / 39

64

RZQG71L8Y1

990 x 940 x 320

80

2.57

4

16

3/8 / 5/8

50

30

30

2.9

48

64

RZQG100L8Y1 RZQG125L8Y1

1430 x 940 x 320

101

3ph

3.58

4

20

5.29

4

20

3+E / 1.5

3/8 / 5/8

75

30

30

Refer to Installation Manual

4.0

50

66

3/8 / 5/8

75

30

30

4.0

51

67

FUQ125C

13.60

9.30

12.00

13.50

A+

12.00

5.61

748

A+

14.13

4.44

4456

3.4 / 4.04

A / A

1770

32.5 / 20.5

198

950

950

26

47 / 40

65

ECA Eligible

Trade Fan Coil Price

Trade Condensing Unit Price

Total System Price

Accessories:

Accessory Ref

BRC7C58

EKRORO5

KRP4A53/UK.FB2

RTD-NET/UK.FB2

RTD-10/UK.FB2

RTD-20/UK.FB2

KLIC-DI

KRCS01-4

K.RSS

RS-SE

UK.CWB90-2

UK.CWB140-2

UK.DT2

UK.CGM

UK.CGL

£857.00

£1,191.00

£2,048.00

£940.00

£1,514.00

£2,454.00

£1,037.00

£1,666.00

£2,703.00

Description

Wireless remote controller

Remote on/off control interface kit

Unit/Group adaptor PCB for remote on/off, status indication and temperature setting

Modbus Interface PCB for Sky Air and VRV

Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock

Energy control PCB for Sky Air and VRV

KNX Interface for Sky Air and VRV systems

Remote room mounted temperature sensor

Wireless room mounted temperature sensor and receiver

Service and Configuration Tool for K.RSS

Condensing unit bracket - up to size 71, max weight 90kg of ODU

Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU

Condensate drip tray for use with Sky Air ODU - tray width 1100mm

Condensing Unit Guard size 42-71

Condensing Unit Guard size 100-140 including RXYSQ

● ●

Trade Price

£152.00

£29.00

£92.00

£190.00

£235.00

£251.00

£185.00

£42.00

£89.00

£93.00

£37.00

£46.00

£59.00

£296.00

£354.00

£857.00

£1,227.00

£2,084.00

£940.00

£1,584.00

£2,524.00

£1,037.00

£1,743.00

£2,780.00

Notes: i) All fan coils supplied as standard with

BRC1E52A wired remote controller with

7-day time clock ii) BRC7C58 Trade price will be reduced by £76.00 if ordered in place of the

BRC1E52A iii) All fan coil units standard with auto restart after power failure iv) Minimum ambient operating temperatures:

RZQG

Cooling

-15°C

Heating

-20°C

Features:

> The 4-way blow under ceiling cassettes are the ideal solution for rooms, shops or offices without false ceilings

> Seasonally Efficient Inverter Technology gives up to 25% better efficiency than inverter technology

> Air flow flexibility: air can be discharged in any of 4 directions. Possibility to shut off 1 or 2 flaps enabling the unit to be installed in a corner or small room

> 3 step fan-speed

> Suitable for Twin, Triple and Double Twin applications

> Re-use of existing R22 and R407C piping possible

> Comms, computer and server room cooling possible with EDP setting

> Selectable evaporating & condensing temperature for greater operating efficiency

Price List 2015 21

FCQHG / RZQG

High COP Roundflow Cassette – Seasonal Smart Inverter

Indoor Units

Capacity

Seasonal Efficiency

(EN14825)

COOLING

UK Total Cooling

UK Sensible Cooling

Nominal Cooling

Nominal Heating kW kW kW kW

Energy Label

Pdesign kW

SEER

Annual Energy Consumption kWh

Seasonal Efficiency

(EN14825)

HEATING

Energy Label

Pdesign kW

SCOP

Annual Energy Consumption kWh

Nominal Efficiency EER / COP

Energy Label

Annual Energy Consumption kWh

High / Low m

3

/min Air Flow Rate

Dimensions

(with Decoration Panel)

Sound Pressure

Sound Power

Height

Width

Depth

Weight (with Decoration Panel)

High / Low mm mm mm kg dBA dBA

Outdoor Units

Dimensions

Weight

Electrical Details

Height x Width x Depth

Power Supply

Running Current

Starting Current

Max Fuse Size

Interconnection Wiring Core / Cable size

Piping Connections Liquid / Gas

Pipework Maximum Length

Maximum Vertical Rise

Sound Pressure

Sound Power

Precharged to

Additional Charge

Holding Charge

High mm kg

A

A

A inches m m m g/m kg dBA dBA

ECA Eligible

Trade Fan Coil Price

Trade Condensing Unit Price

Total System Price

Single Phase 3 Phase

FCQHG71F FCQHG100F FCQHG125F FCQHG140F FCQHG71F FCQHG100F FCQHG125F FCQHG140F

7.76

5.32

10.80

7.44

13.60

9.30

14.90

10.25

7.76

5.32

10.80

7.44

13.60

9.30

14.90

10.25

6.80

7.50

A++

6.80

9.50

10.80

A++

9.50

12.00

13.50

A++

12.00

13.40

15.50

-

-

6.80

7.50

A++

6.80

9.50

10.80

A++

9.50

12.00

13.50

A++

12.00

13.40

15.50

-

-

7.00

340

A+

7.60

4.54

2343

4.09 / 4.8

A / A

7.00

475

A++

11.30

4.80

3295

4.42 / 4.99

A / A

6.61

635

A++

12.66

4.63

3829

4 / 4.4

A / A

-

-

-

-

-

-

3.35 / 4.12

A / A

7.00

340

A+

7.60

4.54

2343

4.09 / 4.8

A / A

7.00

475

A++

11.30

4.80

3295

4.42 / 4.99

A / A

6.61

635

A++

12.66

4.63

3829

4 / 4.4

A / A

-

-

-

-

-

-

3.35 / 4.14

A / A

830

21.2 / 12.2

288(348)

840 (950)

840 (950)

25 (30.4)

36 / 29

53

1075

32.3 / 19

288 (348)

840 (950)

840 (950)

26 (31.4)

44 / 33

61

1500

33.5 / 19.9

288 (348)

840 (950)

840 (950)

26 (31.4)

45 / 35

61

2000

33.5 / 21.1

288 (348)

840 (950)

840 (950)

26 (31.4)

45 / 37

61

830

21.2 / 12.2

288(348)

840 (950)

840 (950)

25 (30.4)

36 / 29

53

1075

32.3 / 19

288 (348)

840 (950)

840 (950)

26 (31.4)

44 / 33

61

1500

33.5 / 19.9

288 (348)

840 (950)

840 (950)

26 (31.4)

45 / 35

61

2000

33.5 / 21.1

288 (348)

840 (950)

840 (950)

26 (31.4)

45 / 37

61

RZQG71L9V1 RZQG100L9V1 RZQG125L9V1 RZQG140L9V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1

990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320

78 102 80 101

1ph 3ph

6.78

4

20

8.79

4

32

12.26

4

32

16.35

4

32

2.55

4

16

3.31

4

20

4.61

4

20

6.15

4

20

3/8 / 5/8

50

30

30

2.9

48

64

3+E / 1.5

3/8 / 5/8 3/8 / 5/8

75

30

75

30

30 30

Refer to Installation Manual

4.0

50

66

4.0

51

67

3/8 / 5/8

75

30

30

4.0

52

69

3/8 / 5/8

50

30

30

2.9

48

64

75

30

3+E / 1.5

3/8 / 5/8 3/8 / 5/8

75

30

30 30

Refer to Installation Manual

4.0

50

66

4.0

51

67

3/8 / 5/8

75

30

30

4.0

52

69

£787.00

£1,191.00

£1,978.00

£890.00

£1,514.00

£2,404.00

£972.00

£1,666.00

£2,638.00

£1,168.00

£1,901.00

£3,069.00

£787.00

£1,227.00

£2,014.00

£890.00

£1,584.00

£2,474.00

£972.00

£1,743.00

£2,715.00

£1,168.00

£2,002.00

£3,170.00

Accessories:

Accessory Ref

BRC7FA532F

BYCQ140DG

BYCQ140DW

BRYQ140A

KDBHQ55B140

KDDQ55B140 1&2

KRP4A53/UK.FB2

RTD-NET/UK.FB2

RTD-10/UK.FB2

RTD-20/UK.FB2

KLIC-DI

KRCS01-4

K.RSS

RS-SE

UK.CWB90-2

UK.CWB140-2

UK.DT2

UK.CGM

UK.CGL

Description

Wireless remote controller

Roundflow cassette decoration panel with self cleaning filter

Roundflow cassette decoration panel - white with white louvres

Integral PIR Sensor for Roundflow decoration panel. Enables Energy Saving functions

Sealing member for air discharge outlet

Fresh air intake kit for up to 20% fresh air - 2 part kit

Unit/Group adaptor PCB for remote on/off, status indication and temperature setting

Modbus Interface PCB for Sky Air and VRV

Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock

Energy control PCB for Sky Air and VRV

KNX Interface for Sky Air and VRV systems

Remote room mounted temperature sensor

Wireless room mounted temperature sensor and receiver

Service and Configuration Tool for K.RSS

Condensing unit bracket - up to size 71, max weight 90kg of ODU

Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU

Condensate drip tray for use with Sky Air ODU - tray width 1100mm

Condensing Unit Guard size 42-71

Condensing Unit Guard size 100-140 including RXYSQ

Trade Price

£152.00

£310.00

£160.00

£99.00

£90.00

£233.00

£92.00

£190.00

£235.00

£251.00

£185.00

£42.00

£89.00

£93.00

£37.00

£46.00

£59.00

£296.00

£354.00

Notes: i) All fan coils supplied as standard with

BRC1E52A wired remote controller with

7-day time clock ii) BRC7FA532F Trade price will be reduced by £76.00 if ordered in place of the

BRC1E52A iii) All fan coil units standard with auto restart after power failure iv) All fan coils suppled as standard with

BYCQ140D Decoration panel v) BYCQ140DW / BYCQ140DG Trade prices will be reduced by £142.00 if ordered in place of standard decoration panel vi) Minimum ambient operating temperatures:

RZQG

RZQSG

AZQS

Cooling

-15°C

-15°C

-5°C

Heating

-20°C

-15°C

-15°C

Features: vii) FCQG-F / FCQHG-F compatible with

> The FCQHG model is designed for 2014 ErP regulations and has one of the highest COP values on the market

> The unique 360° radial air pattern ensures uniform air flow and temperature distribution

> Air flow flexibility: a wide selection of 23 different air flow patterns accessible via remote controller

> Optional Presence Sensors detects if room is unoccupied and allows temperature to drift to set-back levels

> Optional Self Cleaning Filter The BYCQ140DG decoration panel can offer energy savings, reduced maintenance time and cost

> Optional Fresh Air intake (up to 20%) possible

> Suitable for Twin, Triple and Double Twin applications (Smart & Classic)

> Re-use of existing R22 and R407C piping possible

> Comms, computer and server room cooling possible with EDP setting (Seasonal Smart)

> Selectable evaporating & condensing temperature for greater operating efficiency (Seasonal Smart)

> DIII net compatibility as standard

RZQG / RZQSG viii) FCQG-F / FCQHG-F are same price

22 Residential, Commercial and Industrial

FCQG / RZQSG

Compact Roundflow Cassette – Seasonal Classic Inverter

Indoor Units

Capacity

Seasonal Efficiency

(EN14825)

COOLING

UK Total Cooling

UK Sensible Cooling

Nominal Cooling

Nominal Heating

Energy Label

Pdesign

SEER kW kW kW kW kW

Seasonal Efficiency

(EN14825)

HEATING

Nominal Efficiency

Air Flow Rate

Dimensions

(with Decoration Panel)

Annual Energy Consumption

Energy Label

Pdesign

SCOP

Annual Energy Consumption

EER / COP kWh

Energy Label

Annual Energy Consumption kWh

High / Low

Height

Width

Depth

Weight (with Decoration Panel)

Sound Pressure

Sound Power

High / Low kWh kW m 3 /min mm mm mm kg dBA dBA

Outdoor Units

Dimensions

Weight

Electrical Details

Height x Width x Depth

Power Supply

Running Current

Starting Current

Max Fuse Size

Interconnection Wiring Core / Cable size

Piping Connections

Pipework

Liquid / Gas

Maximum Length

Sound Pressure

Sound Power

Maximum Vertical Rise

Precharged to

Additional Charge

Holding Charge

High mm kg

A

A

A inches m m m g/m kg dBA dBA

ECA Eligible

Trade Fan Coil Price

Trade Condensing Unit Price

Total System Price

FCQG71F

7.28

4.99

6.80

7.50

A++

6.80

6.10

390

A+

6.33

4.10

2162

3.21 / 3.61

A / A

971

15 / 9.1

204 (264)

840 (950)

840 (950)

21 (26.4)

33 / 28

51

Single Phase

FCQG100F FCQG125F

10.80

7.44

9.50

13.60

9.30

12.00

10.80

A++

9.50

6.50

511

A+

7.60

4.10

2595

3.3 / 3.54

A / B

1440

22.8 / 12.4

246 (306)

840 (950)

840 (950)

24 (29.4)

37 / 29

54

13.50

A

12.00

5.30

792

A+

8.03

4.01

2803

3.21 / 3.41

A / B

1870

26 / 12.4

246 (306)

840 (950)

840 (950)

24 (29.4)

41 / 29

58

FCQG140F

14.90

10.25

13.40

15.50

-

-

-

-

-

-

-

-

3.01 / 3.41

B / B

2225

26 / 12.4

246 (306)

840 (950)

840 (950)

24 (29.4)

41 / 29

58

FCQG100F

10.80

7.44

9.50

10.80

A++

9.50

6.50

511

A+

7.60

4.10

2595

3.3 / 3.54

A / B

1440

22.8 / 12.4

246 (306)

840 (950)

840 (950)

24 (29.4)

37 / 29

54

3 Phase

FCQG125F

13.60

9.30

12.00

13.50

A

12.00

5.30

792

A+

8.03

4.01

2803

3.21 / 3.41

A / B

1870

26 / 12.4

246 (306)

840 (950)

840 (950)

24 (29.4)

41 / 29

58

RZQSG71L3V1 RZQSG100L9V1 RZQSG125L9V1 RZQSG140L9V1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1

770 x 900 x 320 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320

67 81

1ph

102 82

3ph

101

8.66

4

20

3/8 / 5/8

50

30

30

2.75

49

65

11.77

4

32

3/8 / 5/8

50

30

30

3+E / 1.5

15.29

4

32

3/8 / 5/8

50

30

30

Refer to Installation Manual

2.9

2.9

53

69

54

70

18.19

4

32

3/8 / 5/8

50

30

30

4.0

53

69

4.40

4

20

3/8 / 5/8

50

30

30

2.9

53

69

5.72

4

20

3+E / 1.5

3/8 / 5/8

50

30

30

Refer to Installation Manual

2.9

54

70

6.80

4

20

3/8 / 5/8

50

30

30

4.0

53

69

FCQG140F

14.90

10.25

13.40

15.50

-

-

-

-

-

-

-

-

3.01 / 3.41

B / B

2225

26 / 12.4

246 (306)

840 (950)

840 (950)

24 (29.4)

41 / 29

58

£787.00

£820.00

£1,607.00

£890.00

£1,135.00

£2,025.00

£972.00

£1,245.00

£2,217.00

£1,168.00

£1,386.00

£2,554.00

£890.00

£1,170.00

£2,060.00

£972.00

£1,282.00

£2,254.00

£1,168.00

£1,428.00

£2,596.00

Accessories:

Accessory Ref

BRC7FA532F

BYCQ140DG

BYCQ140DW

BRYQ140A

KDBHQ55B140

KDDQ55B140 1&2

KRP4A53/UK.FB2

RTD-NET/UK.FB2

RTD-10/UK.FB2

RTD-20/UK.FB2

KLIC-DI

KRCS01-4

K.RSS

RS-SE

UK.CWB90-2

UK.CWB140-2

UK.DT2

UK.CGM

UK.CGL

Description

Wireless remote controller

Roundflow cassette decoration panel with self cleaning filter

Roundflow cassette decoration panel - white with white louvres

Integral PIR Sensor for Roundflow decoration panel. Enables Energy Saving functions

Sealing member for air discharge outlet

Fresh air intake kit for up to 20% fresh air - 2 part kit

Unit/Group adaptor PCB for remote on/off, status indication and temperature setting

Modbus Interface PCB for Sky Air and VRV

Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock

Energy control PCB for Sky Air and VRV

KNX Interface for Sky Air and VRV systems

Remote room mounted temperature sensor

Wireless room mounted temperature sensor and receiver

Service and Configuration Tool for K.RSS

Condensing unit bracket - up to size 71, max weight 90kg of ODU

Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU

Condensate drip tray for use with Sky Air ODU - tray width 1100mm

Condensing Unit Guard size 42-71

Condensing Unit Guard size 100-140 including RXYSQ

Trade Price

£152.00

£310.00

£160.00

£99.00

£90.00

£233.00

£92.00

£190.00

£235.00

£251.00

£185.00

£42.00

£89.00

£93.00

£37.00

£46.00

£59.00

£296.00

£354.00

Notes: i) All fan coils supplied as standard with

BRC1E52A wired remote controller with

7-day time clock ii) BRC7FA532F Trade price will be reduced by £76.00 if ordered in place of the

BRC1E52A iii) All fan coil units standard with auto restart after power failure iv) All fan coils suppled as standard with

BYCQ140D Decoration panel v) BYCQ140DW / BYCQ140DG Trade prices will be reduced by £142.00 if ordered in place of standard decoration panel vi) Minimum ambient operating temperatures:

RZQG

RZQSG

AZQS

Cooling

-15°C

-15°C

-5°C

Heating

-20°C

-15°C

-15°C

Features: vii) FCQG-F / FCQHG-F compatible with

RZQG / RZQSG

> FCQG is the slimmer cassette on the market, able to fit in narrower ceilings

> The unique 360° radial air pattern ensures uniform air flow and temperature distribution

> Air flow flexibility: a wide selection of 23 different air flow patterns accessible via remote controller

> Optional Presence Sensors detects if room is unoccupied and allows temperature to drift to set-back levels viii) FCQG-F / FCQHG-F are same price

> Optional Self Cleaning Filter The BYCQ140DG decoration panel can offer energy savings, reduced maintenance time and cost

> Optional Fresh Air intake (up to 20%) possible

> Suitable for Twin, Triple and Double Twin applications (Classic)

> Re-use of existing R22 and R407C piping possible (Classic & Inverter)

> DIII net compatibility as standard

Price List 2015 23

ACQ-D / AZQS

4-Way Blow Cassette – Inverter

Indoor Units

Capacity

Seasonal Efficiency

(EN14825)

COOLING

UK Total Cooling

UK Sensible Cooling

Nominal Cooling

Nominal Heating kW kW kW kW

Energy Label

Pdesign kW

SEER

Annual Energy Consumption kWh

Energy Label

Pdesign kW

Seasonal Efficiency

(EN14825)

HEATING

Nominal Efficiency

Air Flow Rate

Dimensions

(with Decoration Panel)

SCOP

Annual Energy Consumption kWh

EER / COP

Energy Label

Annual Energy Consumption kWh

High / Low m

3

/min

Height

Width mm mm

Depth

Weight (with Decoration Panel) mm kg

Sound Pressure

Sound Power

High / Low dBA dBA

Outdoor Units

Dimensions

Weight

Electrical Details

Height x Width x Depth

Power Supply

Running Current

Starting Current

Max Fuse Size

Interconnection Wiring Core / Cable size

Piping Connections Liquid / Gas

Pipework Maximum Length

Maximum Vertical Rise

Sound Pressure

Sound Power

Precharged to

Additional Charge

Holding Charge

High

Trade Fan Coil Price

Trade Condensing Unit Price

Total System Price

A

A

A mm kg inches m m m g/m kg dBA dBA

3.80

2323

3.31 / 3.61

A / A

1025

24.4 / 17.6

265 (347)

820 (990)

820 (990)

31 (35)

41 / 35

54

ACQ71D

7.28

4.99

6.80

7.50

B

6.80

4.65

512

A

6.33

AZQS71BV1

770X900X320

67

8.38

4

20

3/8 / 5/8

30

15

30 data-book

48

64

£644.00

£714.00

£1,358.00

3.85

2762

3.21 / 3.61

A / A

1480

29.2 / 21.0

300 (382)

820 (990)

820 (990)

39 (43)

44 / 38

56

Single Phase

ACQ100D ACQ125D

10.80

7.44

9.50

10.80

A

9.50

5.50

605

A

7.60

-

-

-

-

13.60

9.30

12.10

13.50

-

-

-

-

3.10 / 3.61

B / A

1952

34.0 / 26.3

300 (382)

820 (990)

820 (990)

39 (43)

47 / 43

60

-

-

3.21 / 3.61

A / A

2025

34.0 / 26.3

300 (382)

820 (990)

820 (990)

39 (43)

47 / 43

60

ACQ140D

-

-

-

-

14.90

10.25

13.00

15.50

-

-

3.85

2762

3.21 / 3.61

A / A

1480.00

29.2 / 21.0

300 (382)

820 (990)

820 (990)

39 (43)

44 / 38

56

ACQ100D

10.80

7.44

9.50

10.80

A

9.50

5.50

605

A

7.60

AZQS100BV1 AZQS120BV1 AZQS140B8V1 AZQS100BY1 AZQS125BY1

990X940X320 1430x940x320 990X940X320

12.10

81

1~ / 50 / 220-240

15.94

102

16.55

4.02

82

3~ / 50 / 400

5.30

4

32

4

20

4

32

4

32

3 + E

3/8 / 5/8

30

15

30

3/8 / 5/8

30

15

30 data-book data-book data-book

53

70

54

71

3/8 / 5/8

30

15

30 data-book

53

70

3/8 / 5/8

30

15

30 data-book

53

70

4

20

3 + E

3/8 / 5/8

30

15

30 data-book data-book

54

71

£749.00

£878.00

£1,627.00

£836.00

£986.00

£1,822.00

£997.00

£1,104.00

£2,101.00

£749.00

£926.00

£1,675.00

£836.00

£1,038.00

£1,874.00

-

-

3.10 / 3.61

B / A

1952.00

34.0 / 26.3

300 (382)

820 (990)

820 (990)

39 (43)

47 / 43

60

3 Phase

ACQ125D

-

-

-

-

13.60

9.30

12.10

13.50

-

-

-

-

3.21 / 3.61

A / A

2025

34.0 / 26.3

300 (382)

820 (990)

820 (990)

39 (43)

47 / 43

60

ACQ140D

-

-

-

-

14.90

10.25

13.00

15.50

-

-

AZQS140BY1

1430x940x320

101

5.50

4

20

3/8 / 5/8

30

15

30 data-book

53

70

£997.00

£1,164.00

£2,161.00

Accessories:

Accessory Ref

R04084124324

UK.CWB90-2

UK.CWB140-2

UK.DT1

UK.DT2

UK.CGM

UK.CGL

Description

PCB Adaptor for group control (1 per fan-coil)

Condensing unit bracket - up to size 71

Condensing unit bracket - sizes 100 to 140

Condensate drip tray for use with UK.CWB90-2

Condensate drip tray for use with UK.CWB140-2

Condensing Unit Guard size 42-71

Condensing Unit Guard size 100-140 including RXYSQ

Features:

> 4-way blow cassette

> Hard wired remote ARCWB as standard

> 7 day timer

> Knock out for connection to branch duct

> Auto swing mode for better air distribution

> Suitable for rooms with suspended ceilings

Trade Price

£82.00

£36.00

£46.00

£54.00

£59.00

£296.00

£354.00

Notes: i) Fan-coils supplied with both ARCWB hard wired remote & infra-red remote ii) Replacement Technology not applicable to AZQS iii) All fan coils suppled as standard with

ADP125B decoration panel iv) All fan coil units standard with auto restart after power failure v) Minimum ambient operating temperature:

AZQS

Cooling

-5°C

Heating

-15°C

24 Residential, Commercial and Industrial

FCQG / RXS

Compact Roundflow Cassette – Inverter

Indoor Units

Capacity

Seasonal Efficiency

(EN14825)

COOLING

Seasonal Efficiency

(EN14825)

HEATING

UK Total Cooling

UK Sensible Cooling

Nominal Cooling

Nominal Heating

Energy Label

Pdesign

SEER

Annual Energy Consumption

Energy Label

Pdesign

SCOP

Annual Energy Consumption

EER / COP kW kW kW kW kW kWh kW kWh

Nominal Efficiency

Air Flow Rate

Dimensions

(with Decoration Panel)

Sound Power

Energy Label

Annual Energy Consumption kWh

High / Low

Height

Width

Depth

Weight (with Decoration Panel)

Sound Pressure High / Low m 3 /min mm mm mm kg dBA dBA

Outdoor Units

Dimensions

Weight

Electrical Details

Height x Width x Depth

Power Supply

Running Current

Starting Current

Max Fuse Size

Interconnection Wiring Core / Cable size

Piping Connections Liquid / Gas

Pipework Maximum Length

Sound Pressure

Sound Power

Maximum Vertical Rise

Precharged to

Additional Charge

Holding Charge

High

ECA Eligible mm kg

A

A

A inches m m m g/m kg dBA dBA

RXS35L3

550 x 765 x 285

34

4.00

4.30

10

3+E / 1.5

1/4 / 3/8

20

15

10

20

1.2

48

61

FCQG35F

3.32

2.29

3.40

4.20

A++

3.50

6.35

193

A++

3.32

4.90

949

3.58 / 3.5

A / B

475

12.5 / 8.7

204 (264)

840 (950)

840 (950)

18 (23.4)

31 / 27

49

RXS50L

735 x 825 x 300

47

1ph

6.30

6.80

20

1/4 / 1/2

30

20

10

20

1.7

48

62

FCQG50F

4.89

3.26

5.00

6.00

A++

5.00

6.48

270

A++

4.36

4.29

1426

3.55 / 3.7

A / A

705

12.6 / 8.7

204 (264)

840 (950)

840 (950)

19 (24.4)

31 / 27

49

3+E / 2.5

Trade Fan Coil Price

Trade Condensing Unit Price

Total System Price

£683.00

£552.00

£1,235.00

£699.00

£694.00

£1,393.00

£743.00

£740.00

£1,483.00

Accessories:

Accessory Ref

BRC7FA532F

BYCQ140DG

BYCQ140DW

BRYQ140A

KDBHQ55B140

KDDQ55B140 1&2

KRP4A53/UK.FB2

RTD-NET/UK.FB2

RTD-10/UK.FB2

RTD-20/UK.FB2

KLIC-DI

KRCS01-4

K.RSS

RS-SE

UK.CWB90-2

UK.DT1

UK.CGM

Description

Wireless remote controller

Roundflow cassette decoration panel with self cleaning filter

Roundflow cassette decoration panel - white with white louvres

Integral PIR Sensor for Roundflow decoration panel. Enables Energy Saving functions

Sealing member for air discharge outlet

Fresh air intake kit for up to 20% fresh air - 2 part kit

Unit/Group adaptor PCB for remote on/off, status indication and temperature setting

Modbus Interface PCB for Sky Air and VRV

Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock

Energy control PCB for Sky Air and VRV

KNX Interface for Sky Air and VRV systems

Remote room mounted temperature sensor

Wireless room mounted temperature sensor and receiver

Service and Configuration Tool for K.RSS

Condensing unit bracket - up to size 71, max weight 90kg of ODU

Condensate drip tray for use with Split ODU - tray width 800mm

Condensing Unit Guard size 42-71

Trade Price

£152.00

£310.00

£160.00

£99.00

£90.00

£233.00

£92.00

£190.00

£235.00

£251.00

£185.00

£42.00

£89.00

£93.00

£37.00

£56.00

£296.00

Features:

> FCQG is a compact cassette designed to suit installation in narrower ceiling voids

> The unique 360° radial air pattern ensures uniform air flow and temperature distribution

> Air flow flexibility: a wide selection of 23 different air flow patterns accessible via remote controller

> Optional Presence Sensors detects if room is unoccupied and allows temperature to drift to set-back levels

> Optional Self Cleaning Filter: The BYCQ140DG decoration panel can offer energy savings, reduced maintenance time and cost

> Suitable for Twin, Triple and Double Twin applications

> Re-use of existing R22 and R407C piping possible

> DIII net compatibility as standard

Notes: i) All fan coils supplied as standard with

BRC1E52A wired remote controller with

7-day time clock ii) BRC7FA532F Trade price will be reduced by £76.00 if ordered in place of the

BRC1E52A iii) All fan coil units standard with auto restart after power failure iv) All fan coils suppled as standard with

BYCQ140D Decoration panel v) BYCQ140DW / BYCQ140DG Trade prices will be reduced by £142.00 if ordered in place of standard decoration panel vi) Minimum ambient operating temperatures:

RXS

Cooling

-10°C

Heating

-15°C

FCQG60F

5.57

3.67

5.70

7.00

A++

5.70

6.22

321

A+

4.71

4.00

1646

3.48 / 3.52

A / B

820

13.6 / 8.7

204 (264)

840 (950)

840 (950)

19 (24.4)

33 / 28

51

RXS60L

735 x 825 x 300

48

7.40

9.40

20

1/4 / 1/2

30

20

10

20

1.5

49

62

Price List 2015 25

FFQ / RXS

600x600 Fully Flat Cassette

Indoor Units

Capacity

Seasonal Efficiency

(EN14825)

COOLING

UK Total Cooling

UK Sensible Cooling

Nominal Cooling

Nominal Heating

Energy Label

Pdesign

SEER kW kW kW kW kW

Seasonal Efficiency

(EN14825)

HEATING

Nominal Efficiency

Air Flow Rate

Dimensions

(with Decoration Panel)

Annual Energy Consumption kWh

Energy Label

Pdesign

SCOP kW

Annual Energy Consumption kWh

EER / COP

Energy Label

Annual Energy Consumption kWh

High / Low

Height

Width

Depth

Weight (with Decoration Panel)

Sound Pressure

Sound Power

High / Low m 3 /min mm mm mm kg dBA dBA

Outdoor Units

Dimensions

Weight

Electrical Details

Height x Width x Depth

Interconnection Wiring

Piping Connections

Pipework

Sound Pressure

Sound Power

ECA Eligible

Trade Fan Coil Price

Trade Condensing Unit Price

Total System Price

Power Supply

Running Current

Starting Current

Max Fuse Size

Core / Cable size

Liquid / Gas

Maximum Length

Maximum Vertical Rise

Precharged to

Additional Charge

Holding Charge

High mm kg

A

A

A inches m m m g/m kg dBA dBA

FFQ25C

2.44

1.81

2.50

3.20

A++

2.50

6.11

143

A+

2.31

4.24

763

4.46 / 3.9

A / A

280

9 / 6.5

260 (306)

575 (620)

575 (620)

17.5 (20.2)

31 / 25

48

RXS25L3

550 x 765 x 285

34

4.00

3.3

10

1/4 / 3/8

20

15

10

1.0

46

61

£636.00

£476.00

£1,112.00

3+E / 1.5

FFQ35C

3.32

2.28

3.40

4.00

A++

3.40

6.32

188

A+

3.10

4.10

1059

3.7 / 3.5

A / B

460

10 / 6.5

260 (306)

575 (620)

575 (620)

17.5 (20.2)

34 / 25

51

RXS35L3

550 x 765 x 285

34

4.00

4.3

10

1/4 / 3/8

20

15

10

1.2

48

61

£696.00

£552.00

£1,248.00

1ph

20

FFQ50C

4.62

3.40

4.70

5.50

A+

5.00

5.93

295

A

3.84

3.90

1378

3.21 / 3.49

A / B

780

12 / 7.5

260 (306)

575 (620)

575 (620)

17.5 (20.2)

39 / 27

56

RXS50L

735 x 825 x 300

47

6.90

6.8

20

1/4 / 1/2

30

20

10

1.7

48

62

3+E / 2.5

FFQ60C

5.72

4.20

5.80

7.00

A+

5.80

5.71

349

A+

3.96

4.04

1373

3.02 / 3.41

B / B

945

14.5 / 9.5

260 (306)

575 (620)

575 (620)

17.5 (20.2)

43 / 32

60

RXS60L

735 x 825 x 300

48

8.30

9.4

20

1/4 / 1/2

30

20

10

1.5

49

62

£766.00

£694.00

£1,460.00

£809.00

£740.00

£1,549.00

Accessories:

Accessory Ref

BYFQ60CW

BYFQ60CS

BYFQ60B3

BRYQ60AW

BRYQ60AS

BRC7F530W

BRC7F530S

BRC7EB530W

BDBHQ44C60

KRP4A53/UK.FB2

KRP1B57/UK.FB2

RTD-NET/UK.FB2

RTD-10/UK.FB2

RTD-20/UK.FB2

KLIC-DI

KRCS01-4

K.RSS

RS-SE

UK.CWB90-2

UK.DT1

UK.CGS

UK.CGM

Description

Fully Flat Cassette Decoration Panel - White

Fully Flat Cassette Decoration Panel - Sliver

Fully Flat Cassette Decoration Panel - Old Style (FFQ-B9V looks)

Integral PIR Sensor for Fully Flat cassette White decoration panel. Enables Energy Saving functions

Integral PIR Sensor for Fully Flat Cassette Silver decoration panel. Enables Energy Saving functions

Wireless remote controller for White Ceiling Decoration Panel

Wireless remote controller for Silver Ceiling Decoration Panel

Wireless remote for Fully Flat Cassette Old Style Decoration Panel

Sealing member for decoration panel-FFQ,FXZQ

Unit/Group adaptor PCB for remote on/off, status indication and temperature setting

Adaptor PCB for Interlock to fresh air fan

Modbus Interface PCB for Sky Air and VRV

Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock

Energy control PCB for Sky Air and VRV

KNX Interface for Sky Air and VRV systems

Remote room mounted temperature sensor

Wireless room mounted temperature sensor and receiver

Service and Configuration Tool for K.RSS

Condensing unit bracket - up to size 71, max weight 90kg of ODU

Condensate drip tray for use with Split ODU - tray width 800mm

Condensing Unit Guard size 20-35

Condensing Unit Guard size 42-71

Notes: i) All fan coils supplied as standard with

BRC1E52A wired remote controller with

7-day time clock ii) Infrared remote Trade price will be reduced by £76.00 if ordered instead of

BRC1E52A iii) All fan coil units standard with auto restart after power failure iv) All fan coils suppled as standard with BYFQ60CW White fully flat decoration panel v) Minimum ambient operating temperatures:

RXS

Cooling

-10°C

Heating

-15°C

Features:

> Installed into suspended ceiling grids without cutting surrounding tiles

> Home Leave setting maintains pre-set temperature during periods of extended absence

> Dry programme: Daikin’s special dry programme reduces humidity in the rooms without variations in internal temperature

> Vertical auto-swing function: flaps automatically swing up and down to ensure efficient air and temperature distribution which also prevents ceiling soiling

> 3 fan speeds can be selected: high, medium and low

> Suitable for Twin, Triple and Double Twin applications. Also suitable for multi model applications

> Re-use of existing R22 and R407C piping possible

26 Residential, Commercial and Industrial

Trade Price

£198.00

£198.00

£170.00

£99.00

£99.00

£152.00

£152.00

£152.00

£91.00

£92.00

£100.00

£190.00

£235.00

£251.00

£185.00

£42.00

£89.00

£93.00

£37.00

£56.00

£214.00

£296.00

NEW

AVAILABLE

SUMMER 2015

Indoor Units

FNQ-A / RXS

Vertical Chassis Unit

Capacity

Seasonal Efficiency

(EN14825

COOLING

UK Total Cooling

UK Sensible Cooling

Nominal Cooling

Nominal Heating

Energy Label

Pdesign

SEER

Annual Energy Consumption

Energy Label

Pdesign

Seasonal Efficiency

(EN14825)

HEATING

Nominal Efficiency

SCOP

Annual Energy Consumption

EER / COP

Energy Label

Air Flow Rate

Annual Energy Consumption

High / Low

External Static Pressure High / Nominal

Dimensions Height

Width

Depth

Weight

Sound Pressure

Sound Power

High / Low

Outdoor Units

Dimensions

Weight

Electrical Details

Height x Width x Depth

Power Supply

Running Current

Starting Current

Max Fuse Size

Interconnection Wiring Core / Cable size

Piping Connections

Pipework

Liquid / Gas

Maximum Length

Sound Pressure

Sound Power

Maximum Vertical Rise

Precharged to

Additional Charge

Holding Charge

High

Trade Fan Coil Price

Trade Condensing Unit Price

Total System Price

kW kW kW kW kW kWh kW kWh

A

A

A mm kg inches m m m g/m kg dBA dBA kWh m

3

/min

Pa mm mm mm kg dBA dBA

FNQ25A

2.35*

1.81*

2.40

3.20

A+*

2.40*

5.63*

149.00*

A+*

2.60*

4.24*

858*

3.69 / 4.00*

A / A*

325*

8.7 / 7.3*

30 / 10*

620*

750*

200*

21*

TBC

TBC

RXS25L3

550 x 765 x 285

34

3.90*

3.3*

10

1/4 / 3/8

20

15

10

1.0

46

59

£407.00

£476.00

£883.00

3+E / 1.5

FNQ35A

3.32*

2.26*

3.40

4.00

A*

3.40*

5.21*

228.00*

A*

2.90*

3.88*

1047*

3.21 / 3.48*

A / B*

530*

Vertical Ducted

FNQ50A

4.81*

3.08*

5.00

5.80

A+*

5.00*

5.72*

306.00*

A*

4.00*

3.93*

1425*

3.03 / 3.10*

B / D*

825*

21*

TBC

TBC

RXS35L3

550 x 765 x 285

34

4.90*

4.3*

10

1/4 / 3/8

20

15

10

1.2

48

61

£503.00

£552.00

£1,055.00

1ph

20

30*

TBC

TBC

RXS50L

735 x 825 x 300

47

7.10*

6.8*

20

1/4 / 1/2

30

20

10

1.7

48

62

£586.00

£694.00

£1,280.00

16 / 13.5*

44 / 15*

620*

1150*

200*

3+E / 2.5

30*

TBC

TBC

RXS60L

735 x 825 x 300

48

9.20*

9.4*

20

FNQ60A

5.86*

3.97*

6.00

7.00

A*

6.00*

5.51*

381.00*

A*

4.60*

3.80*

1693*

2.91 / 3.21*

C / C*

1031*

1/4 / 1/2

30

20

10

1.5

49

62

£646.00

£740.00

£1,386.00

Accessories:

Accessory Ref Description

BRC4C65

BRC2E52

Wireless remote controller

Wired Simplified remote controller (without auto swing)

Recessed simplified remote (see page 81 for options)

KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/off, status indication and temperature setting

RTD-NET/UK.FB2

Modbus Interface PCB for Sky Air and VRV

RTD-10/UK.FB2

Enhanced function PCB for Sky Air & VRV. Duty rotation, Lead Lag control & heating interlock

RTD-20/UK.FB2

KLIC-DI

Energy control PCB for Sky Air and VRV

KNX Interface for Sky Air and VRV systems

KRCS01-4B

K.RSS

RS-SE

UK.CWB90-2

UK.DT1

UK.CGS

UK.CGM

Remote room mounted temperature sensor

Wireless room mounted temperature sensor and receiver

Service and Configuration Tool for K.RSS

Condensing unit bracket - up to size 71, max weight 90kg of ODU

Condensate drip tray for use with Split ODU - tray width 800mm

Condensing Unit Guard size 20-35

Condensing Unit Guard size 42-71

Trade Price

£152.00

£80.00

£180.00

£92.00

£190.00

£235.00

£251.00

£185.00

£42.00

£89.00

£93.00

£37.00

£56.00

£214.00

£296.00

Notes: i) Fan-coils supplied with BRC1E52A hard wired remote ii) All fan coil units standard with auto restart after power failure iii) Fan-coils supplied as standard with air filter iv) Minimum ambient operating temperature:

RXS

Cooling

-10°C

Heating

-15°C v) * Provisional data

Features:

> Requires very little installation space

> Low height makes it ideal for installation beneath window

> Connect to multi for residential solution

> Connect to Sky Air for twin, triple or double applications

> External static pressure of up to 44Pa

Price List 2015 27

FBQ / RZQG

Built in DC Ducted – Seasonal Smart Inverter

Indoor Units

Capacity

Seasonal Efficiency

(EN14825)

COOLING

UK Total Cooling

UK Sensible Cooling

Nominal Cooling

Nominal Heating kW kW kW kW

Energy Label

Pdesign kW

SEER

Annual Energy Consumption kWh

Energy Label

Pdesign kW

Seasonal Efficiency

(EN14825)

HEATING

Nominal Efficiency

SCOP

Annual Energy Consumption kWh

EER / COP

Energy Label

Air Flow Rate

Annual Energy Consumption kWh

High / Low

External Static Pressure High / Standard m

Pa

3

/min

Dimensions Height

Width mm mm

Depth mm

Weight

Sound Pressure

Sound Power

High / Low kg dBA dBA

Outdoor Units

Dimensions

Weight

Electrical Details

Sound Pressure

Sound Power

Height x Width x Depth

Power Supply

Running Current

Starting Current

Max Fuse Size

Interconnection Wiring Core / Cable size

Piping Connections

Pipework

Liquid / Gas

Maximum Length

Maximum Vertical Rise

Precharged to

Additional Charge

Holding Charge

High mm kg

A

A

A inches m m m g/m kg dBA dBA

FBQ71D

7.76

5.32

6.80

7.50

A++

6.80

6.16

386

A+

6.00

4.31

1949

3.60 / 4.01

A / A

TBC

18 / 12.5

150 / 30

1000

Single Phase

FBQ100D FBQ125D

10.80

7.44

9.50

10.80

A+

9.50

5.87

566

A++

11.30

13.60

9.30

12.00

13.50

A++

12.00

6.11

687

A+

12.71

4.78

3310

3.81 / 4.41

A / A

TBC

29 / 23

150 / 40

4.28

4154

3.31 / 3.90

A / A

TBC

34 / 23.5

150 / 50

-

-

3.35 / 3.60

A / B

TBC

FBQ140D

-

-

-

-

14.90

10.25

13.40

15.50

-

-

245

1400

800

46

34 / 30

58 62

37 / 32

62

FBQ71D

7.76

5.32

6.80

7.50

A++

6.80

6.16

386

A+

6.00

4.31

1949

3.60 / 4.01

A / A

TBC

18 / 15

150 / 30

1000

3 Phase

FBQ100D FBQ125D

10.80

7.44

9.50

10.80

A+

9.50

5.87

566

A++

11.30

13.60

9.30

12.00

13.50

A++

12.00

6.11

687

A+

12.71

4.78

3310

3.81 / 4.41

A / A

TBC

32 / 23

150 / 40

4.28

4154

3.31 / 3.90

A / A

TBC

34 / 23.5

150 / 50

-

-

3.35 / 3.60

A / B

TBC

FBQ140D

-

-

-

-

14.90

10.25

13.40

15.50

-

-

245

1400

800

46

34 / 30

58 62

37 / 32

62

35

30 / 25

56

35

30 / 25

56

RZQG71L9V1 RZQG100L9V1 RZQG125L9V1 RZQG140L9V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1

990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320

78 102 80 101

1ph 3ph

7.93

4

20

3/8 / 5/8

50

30

30

9.97

4

32

12.87

4

32

3+E / 1.5

3/8 / 5/8 3/8 / 5/8

75

30

75

30

30 30

Refer to Installation Manual

4.0

4.0

16.43

4

32

3/8 / 5/8

75

30

30

2.98

4

16

3/8 / 5/8

50

30

30

3.75

4

20

3/8 / 5/8

75

30

30

3+E / 1.5

4.84

4

20

3/8 / 5/8

75

30

30

Refer to Installation Manual

4.0

4.0

6.18

4

20

3/8 / 5/8

75

30

30

2.9

48

64

50

66

51

67

4.0

52

69

2.9

48

64

50

66

51

67

4.0

52

69

ECA Eligible

Trade Fan Coil Price

Trade Condensing Unit Price

Total System Price

£860.00

£1,191.00

£2,051.00

£899.00

£1,514.00

£2,413.00

£1,063.00

£1,666.00

£2,729.00

£1,232.00

£1,901.00

£3,133.00

£860.00

£1,227.00

£2,087.00

£899.00

£1,584.00

£2,483.00

£1,063.00

£1,743.00

£2,806.00

£1,232.00

£2,002.00

£3,234.00

Accessories:

Accessory Ref

BRC4C65

BRC2E52

KRP4A53/UK.FB2

RTD-NET/UK.FB2

RTD-10/UK.FB2

RTD-20/UK.FB2

KLIC-DI

KRCS01-4

K.RSS

RS-SE

UK.RAC

UK.SAF

UK.CWB90-2

UK.CWB140-2

UK.DT2

UK.CGM

UK.CGL

Description

Wireless remote controller

Wired Simplified remote controller (without auto swing)

Recessed simplified remote (see page 81 for options)

Unit/Group adaptor PCB for remote on/off, status indication and temperature setting

Modbus Interface PCB for Sky Air and VRV

Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock.

Energy control PCB for Sky Air and VRV.

KNX Interface for Sky Air and VRV systems

Remote room mounted temperature sensor

Wireless room mounted temperature sensor and receiver

Service and Configuration Tool for K.RSS

Return Air Chambers are available – contact your branch for details

Supply Air Flanges are available – contact your branch for details

Condensing unit bracket - up to size 71, max weight 90kg of ODU

Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU

Condensate drip tray for use with Sky Air ODU - tray width 1100mm

Condensing Unit Guard size 42-71

Condensing Unit Guard size 100-140 including RXYSQ

Trade Price

£152.00

£90.00

£180.00

£92.00

£190.00

£235.00

£251.00

£185.00

£42.00

£89.00

£93.00

POA

POA

£37.00

£46.00

£59.00

£296.00

£354.00

Features:

> New chassis with height of 245mm makes the FBQ-D one of the slimmest medium static ducted on the market

> Increased external static pressure up to 150 Pa

> Flexibility to set the required fan curve manually or to automatically select the correct fan curve, assuring comfort at all times

> Top efficiency, highest Energy label ranking in the market

Notes: i) All fan coils supplied as standard with

BRC1E52A wired remote controller with

7-day time clock ii) BRC4C65 Trade price will be reduced by £76.00 if ordered in place of the

BRC1E52A iii) All fan coil units standard with auto restart after power failure iv) All fan coils supplied as standard with air filter v) Minimum ambient operating temperatures:

RZQG

RZQSG

Cooling

-15°C

-15°C

Heating

-20°C

-15°C vi) FBQ-D fan coils require a separate 1ph power supply. Refer to install manual for details

28 Residential, Commercial and Industrial

FBQ / RZQSG

Built in DC Ducted – Seasonal Classic Inverter

Indoor Units

Capacity

Seasonal Efficiency

(EN14825)

COOLING

UK Total Cooling

UK Sensible Cooling

Nominal Cooling

Nominal Heating

Energy Label

Pdesign

SEER

Annual Energy Consumption

Energy Label

Pdesign

Seasonal Efficiency

(EN14825)

HEATING

Nominal Efficiency

SCOP

Annual Energy Consumption

EER / COP

Energy Label

Air Flow Rate

Annual Energy Consumption

High / Low

External Static Pressure High / Standard

Dimensions Height

Width

Depth

Weight

Sound Pressure

Sound Power

High / Low

Outdoor Units

Dimensions

Weight

Electrical Details

Height x Width x Depth

Power Supply

Running Current

Starting Current

Max Fuse Size

Interconnection Wiring Core / Cable size

Piping Connections

Pipework

Liquid / Gas

Maximum Length

Maximum Vertical Rise

Precharged to

Sound Pressure

Additional Charge

Holding Charge

High

Sound Power

Trade Fan Coil Price

Trade Condensing Unit Price

Total System Price

kW kW kW kW kW kWh kW kWh

A

A

A inches m m m g/m kg dBA dBA kWh m

3

/min

Pa mm mm mm kg dBA dBA mm kg

FBQ71D

7.28

4.99

6.80

7.50

A+

6.80

5.84

408

A+

6.00

4.01

2095

3.43 / 3.92

A / A

TBC

18 / 12.5

150 / 30

1000

35

30 / 25

56

Single Phase

FBQ100D FBQ125D

10.80

7.44

9.50

10.80

A+

9.50

5.61

593

A+

7.60

13.60

9.30

12.00

13.50

A

12.00

5.47

768

A+

7.60

4.15

2564

3.35 / 3.67

A / A

TBC

29 / 23

150 / 40

4.01

2653

3.23 / 3.63

A / A

TBC

34 / 23.5

150 / 50

-

-

3.06 / 3.40

B / B

TBC

FBQ140D

-

-

-

-

14.90

10.25

13.40

15.50

-

-

245

1400

800

46

34 / 30

58 62

37 / 32

62

FBQ100D

10.80

7.44

9.50

10.80

A+

9.50

5.61

593.00

A+

7.60

4.15

2564.00

3.35 / 3.67

A / A

TBC

29 / 23

150 / 40

34 / 30

58

3 Phase

FBQ125D

13.60

9.30

12.00

13.50

A

12.00

5.47

768.00

A+

7.60

4.01

2653.00

3.23 / 3.63

A / A

TBC

34 / 23.5

150 / 50

-

-

3.06 / 3.40

B / B

TBC

245

1400

800

46

37 / 32

62

FBQ140D

-

-

-

-

14.90

10.25

13.40

15.50

-

-

RZQSG71L3V1 RZQSG100L9V1 RZQSG125L9V1 RZQSG140L9V1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1

770 x 900 x 320 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320

67 81

1ph

102 82

3ph

101

8.46

4

20

3/8 / 5/8

50

15

30

2.75

49

65

11.73

4

32

15.29

4

32

3/8 / 5/8

3+E / 1.5

3/8 / 5/8

50

30

30

50

30

30

Refer to Installation Manual

2.9

53

69

2.9

54

70

18.15

4

32

3/8 / 5/8

50

30

30

4.0

53

69

4.39

4

20

3/8 / 5/8

50

30

30

2.9

53

69

5.72

4

20

3+E / 1.5

3/8 / 5/8

50

30

30

Refer to Installation Manual

2.9

54

70

6.79

4

20

3/8 / 5/8

50

30

30

4.0

53

69

£860.00

£820.00

£1,680.00

£899.00

£1,135.00

£2,034.00

£1,063.00

£1,245.00

£2,308.00

£1,232.00

£1,386.00

£2,618.00

£899.00

£1,170.00

£2,069.00

£1,063.00

£1,282.00

£2,345.00

£1,232.00

£1,428.00

£2,660.00

Price List 2015 29

ABQ-C / AZQS

Concealed Ceiling Unit

Indoor Units

Capacity

Seasonal Efficiency

(EN14825)

COOLING

UK Total Cooling

UK Sensible Cooling

Nominal Cooling

Nominal Heating kW kW kW kW

Energy Label

Pdesign kW

SEER

Annual Energy Consumption kWh

Energy Label

Pdesign kW

Seasonal Efficiency

(EN14825)

HEATING

Nominal Efficiency

SCOP

Annual Energy Consumption kWh

EER / COP

Energy Label

Air Flow Rate

Annual Energy Consumption kWh

High / Low

External Static Pressure High / Nominal m

Pa

3

/min

Dimensions Height

Width

Depth mm mm mm

Weight

Sound Pressure

Sound Power

High / Low kg dBA dBA

Outdoor Units

Dimensions

Weight

Electrical Details

Height x Width x Depth

Power Supply

Running Current

Starting Current

Max Fuse Size

Interconnection Wiring Core / Cable size

Piping Connections

Pipework

Liquid / Gas

Maximum Length

Maximum Vertical Rise

Precharged to

Sound Pressure

Additional Charge

Holding Charge

High

Sound Power

Trade Fan Coil Price

Trade Condensing Unit Price

Total System Price

mm kg

A

A

A inches m m m g/m kg dBA dBA

Accessories:

Accessory Ref

R04084124324

UK.CWB90-2

UK.CWB140-2

UK.DT1

UK.DT2

UK.CGM

UK.CGL

Description

PCB Adaptor for group control (1 per fan-coil)

Condensing unit bracket - up to size 71

Condensing unit bracket - sizes 100 to 140

Condensate drip tray for use with UK.CWB90-2

Condensate drip tray for use with UK.CWB140-2

Condensing Unit Guard size 42-71

Condensing Unit Guard size 100-140 including RXYSQ

Features:

> 7 day timer as standard

> Hard wired remote ARCWA as standard

> Ideal for shops / restaurants with ceiling voids

> High external static pressures for long duct runs

3.80

2082

2.91 / 3.51

C / B

1165

18.3 / 15.4

90 / 70

285

1007

600

35

-

64

ABQ71C

7.28

4.99

6.80

7.50

B

6.80

4.65

512

A

5.65

3.80

2498

2.62 / 3.41

D / B

1813

22.7 / 18.3

70 / 57

378

1045

541

44

41 / 36

60

Single Phase

ABQ100C ABQ125C

10.80

7.44

9.50

10.80

B

9.50

4.65

716

A

6.78

-

-

-

-

13.60

9.30

12.10

13.50

-

-

-

-

2.81 / 3.41

C / B

2153

40.5 / 34.8

150 / 128

378

1299

541

50

53 / 50

-

-

-

3.01 / 3.41

B / B

2159

48.7 / 37.9

150 / 122

378

1499

541

56

55 / 50

-

ABQ140C

-

-

-

-

14.90

10.25

13.00

15.50

-

-

3.80

2498.00

2.62 / 3.41

D / B

1813

22.7 / 18.3

70 / 57

378

1045

541

44

41 / 36

60

ABQ100C

10.80

7.44

9.50

10.80

B

9.50

4.65

716.00

A

6.78

AZQS71BV1 AZQS100B8V1 AZQS125B8V1 AZQS140B8V1 AZQS100BY1 AZQS125BY1

770x900x320 990x940x320 1430x940x320 990x940x320

67 81

1~ / 50 / 220 - 240

102 81

3~ / 50 / 400

9.52

4

20

3/8 / 5/8

30

15

30 data-book

48

64

14.84

4

32

3/8 / 5/8

3+E / 1.5

3/8 / 5/8

30

15

30

30

15

30 data-book data-book data-book

53 54

70

17.57

4

32

71

17.66

4

32

3/8 / 5/8

30

15

30 data-book

53

70

4.93

4

20

3/8 / 5/8

30

15

30 data-book

53

70

5.84

4

20

3+E / 1.5

3/8 / 5/8

30

15

30 data-book data-book

54

71

£623.00

£714.00

£1,337.00

£812.00

£878.00

£1,690.00

£926.00

£986.00

£1,912.00

£969.00

£1,104.00

£2,073.00

£812.00

£926.00

£1,738.00

£926.00

£1,038.00

£1,964.00

-

-

2.81 / 3.41

C / B

2153

40.5 / 34.8

150 / 128

378

1299

541

50

53 / 50

-

3 Phase

ABQ125C

-

-

-

-

13.60

9.30

12.10

13.50

-

-

-

-

3.01 / 3.41

B / B

2159

48.7 / 37.9

150 / 122

378

1499

541

56

55 / 50

-

ABQ140C

-

-

-

-

14.90

10.25

13.00

15.50

-

-

AZQS140BY1

1430x940x320

101

5.87

4

20

3/8 / 5/8

30

15

30 data-book

53

70

£969.00

£1,164.00

£2,133.00

Trade Price

£82.00

£36.00

£46.00

£54.00

£59.00

£296.00

£354.00

Notes: i) Fan-coils supplied with ARCWB hard wired remote ii) Replacement Technology not applicable to AZQS iii) All fan coil units standard with auto restart after power failure iv) Fan-coils supplied as standard with air filter v) Minimum ambient operating temperature:

AZQS

Cooling

-5°C

Heating

-15°C

30 Residential, Commercial and Industrial

FBQ & FDXS-F / RXS

Built in DC Ducted & Slim Ducted – Inverter

Indoor Units

Capacity

Seasonal Efficiency

(EN14825)

COOLING

UK Total Cooling

UK Sensible Cooling

Nominal Cooling

Nominal Heating

Energy Label

Pdesign

SEER

Annual Energy Consumption

Energy Label

Pdesign

Seasonal Efficiency

(EN14825)

HEATING

Nominal Efficiency

SCOP

Annual Energy Consumption

EER / COP

Energy Label

Air Flow Rate

Annual Energy Consumption

High / Low

External Static Pressure High / Standard

Dimensions Height

Width

Depth

Weight

Sound Pressure

Sound Power

High / Low

Outdoor Units

Dimensions

Weight

Electrical Details

Height x Width x Depth

Power Supply

Running Current

Starting Current

Max Fuse Size

Interconnection Wiring Core / Cable size

Piping Connections

Pipework

Liquid / Gas

Maximum Length

Maximum Vertical Rise

Precharged to

Sound Pressure

Additional Charge

Holding Charge

High

Sound Power

Trade Fan Coil Price

Trade Condensing Unit Price

Total System Price

kW kW kW kW kW kWh kW kWh

A

A

A inches m m m g/m kg dBA dBA kWh m

3

/min

Pa mm mm mm kg dBA dBA mm kg

FBQ35D

3.32*

2.93*

3.40

4.00

A++

3.40

6.17

193

A+

2.90

4.07

998

3.99 / 4.02

A / A tbc

15 / 10.5

35 / 29

60

700

DC Ducted

FBQ50D

4.89*

3.60*

5.00

5.50

A++

5.00

6.21

282

A+

4.40

4.06

1517

3.52 / 3.83

B / A tbc

15 / 10.5

150 / 30

245

800

28

35 / 29

60

FBQ60D

5.57*

4.10*

5.70

7.00

A+

5.70

5.86

340

A+

4.60

4.01

1606

3.45 / 3.71

B / A tbc

18 / 12.5

1000

56

30 / 25

55

FDXS25F

2.35

1.81

2.40

3.20

A+

2.40

5.63

149

A+

2.60

4.24

858

3.69 / 4

A / A

325

8.7 / 7.3

30.0

35 / 31

53

750

21

Slim Ducted

FDXS35F FDXS50F9

3.32

2.26

3.40

4.00

A

3.40

5.21

228

A

2.90

4.81

3.08

5.00

5.80

A+

5.00

5.72

306

A

4.00

3.88

1047

3.21 / 3.48

A / B

530

8.7 / 7.3

30.0

3.93

1425

3.03 / 3.1

B / D

825

12 / 10

40.0

200

1150

620

30

35 / 31

53

37 / 33

55

FDXS60F

5.86

3.97

6.00

7.00

A

6.00

5.51

381

A

4.60

3.80

1693

2.91 / 3.21

C / C

1030

16 / 13.5

40.0

38 / 34

56

RXS35L3 RXS50L RXS60L RXS25L3 RXS35L3 RXS50L RXS60L

550 x 765 x 285 735 x 825 x 300 735 x 825 x 300 550 x 765 x 285 550 x 765 x 285 735 x 825 x 300 735 x 825 x 300

34 47

1ph (refer to databook)

48 34 34

1ph

47 48

4.6*

4.3

10

3+E / 1.5

1/4 / 3/8

20

15

10

1.2

48

61

7.2*

6.8

20

9.2*

9.4

20

1/4 / 1/2

3+E / 2.5

1/4 / 1/2

30

20

30

20

10 10

20

1.7

48

1.5

49

62 62

3.90

3.3

10

1/4 / 3/8

3+E / 1.5

20

15

10

1.0

46

59

4.90

4.3

10

1/4 / 3/8

20

15

10

1.2

48

61

20

7.10

6.8

20

1/4 / 1/2

3+E / 2.5

30

20

10

1.7

48

62

9.20

9.4

20

1/4 / 1/2

30

20

10

1.5

49

62

£515.00

£552.00

£1,067.00

£541.00

£694.00

£1,235.00

£600.00

£740.00

£1,340.00

£394.00

£476.00

£870.00

£441.00

£552.00

£993.00

£477.00

£694.00

£1,171.00

£524.00

£740.00

£1,264.00

Accessories:

Accessory Ref

BRC4C65

BRC2E52

Description

Wireless remote controller

Wired Simplified remote controller

Recessed simplified remote (see page 81 for options)

KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/off, status indication and temperature setting

RTD-NET/UK.FB2

Modbus Interface PCB for Sky Air and VRV

RTD-10/UK.FB2

Enhanced function PCB for Sky Air & VRV. Duty rotation, Lead Lag control & heating interlock

RTD-20/UK.FB2

KLIC-DI

KRCS01-4B

K.RSS

RS-SE

UK.RAC

Energy control PCB for Sky Air and VRV

KNX Interface for Sky Air and VRV systems

Remote room mounted temperature sensor

Wireless room mounted temperature sensor and receiver

Service and Configuration Tool for K.RSS

Return Air Chambers are available – contact your branch for details

UK.SAF

UK.CWB90-2

UK.DT1

UK.CGS

UK.CGM

Supply Air Flanges are available – contact your branch for details

Condensing unit bracket - up to size 71, max weight 90kg of ODU

Condensate drip tray for use with Split ODU - tray width 800mm

Condensing Unit Guard size 20-35

Condensing Unit Guard size 42-71

Trade Price

£152.00

£80.00

£180.00

£92.00

£190.00

£235.00

£251.00

£185.00

£42.00

£89.00

£93.00

POA

POA

£37.00

£56.00

£214.00

£296.00

Notes: i) FBQ & FDXS fan coils supplied as standard with BRC1E52A wired remote controller with 7-day time clock ii) BRC4C65 Trade price will be reduced by £76.00 if ordered in place of the

BRC1E52A iii) All fan coil units standard with auto restart after power failure iv) All fan coils supplied as standard with air filter v) Minimum ambient operating temperatures:

RXS

Cooling

-10°C

Heating

-15°C vi) FBQ-D fan coils require a separate 1ph power supply. Refer to install manual for details vii) * Provisional data

Features:

> Fan speed: 5 fan speeds can be selected, high to super low

> Connection to multi outdoor possible

> Re-use of existing R22 and R407C piping possible

Price List 2015 31

FDQ

High Static Ducted – Seasonal Smart, Classic & Super Inverter

Indoor Units

Capacity

Seasonal Efficiency

(EN14825)

COOLING

UK Total Cooling

UK Sensible Cooling

Nominal Cooling

Nominal Heating kW kW kW kW

Energy Label

Pdesign kW

SEER

Annual Energy Consumption kWh

Energy Label

Pdesign kW

Seasonal Efficiency

(EN14825)

HEATING

Nominal Efficiency

SCOP

Annual Energy Consumption kWh

EER / COP

Energy Label

Air Flow Rate

Annual Energy Consumption kWh

High / Low

External Static Pressure High / Nominal m

Pa

3

/min

Dimensions Height

Width

Depth mm mm mm

Weight

Sound Pressure

Sound Power

High / Low kg dBA dBA

Outdoor Units

Dimensions

Weight

Electrical Details

Interconnection Wiring

Piping Connections

Pipework

Height x Width x Depth

Sound Pressure

Sound Power

Trade Fan Coil Price

Trade Condensing Unit Price

Total System Price

Power Supply

Running Current

Starting Current

Max Fuse Size

Core / Cable size

Liquid / Gas

Maximum Length

Maximum Vertical Rise

Precharged to

Additional Charge

Holding Charge

High mm kg

A

A

A inches m m m g/m kg dBA dBA

4.21

4226

3.75 / 3.83

A / A

1600

39 / 28

200 / 50

300

1400

700

45

40 / 33

66

Single Phase

FDQ125C

13.60

9.30

12.00

13.50

A+

12.00

5.81

722

A+

12.71

RZQG125L9V1

1430 x 940 x 320

102

1ph - see notes

14.80

4

32

3/8 / 5/8

75

30

30

4.0

51

67

£1,163.00

£1,666.00

£2,829.00

4.21

4226

3.75 / 3.83

A / A

1600

39 / 28

200 / 50

300

1400

700

45

40 / 33

66

3 Phase

FDQ125C

13.60

9.30

12.00

13.50

A+

12.00

5.81

722

A+

12.71

RZQG125L8Y1

1430 x 940 x 320

101

3ph - see notes

RZQSG125L9V1

990 x 940 x 320

81

1ph - see notes

4.89

4

20

17.30

4

32

3+E / 1.5

3/8 / 5/8

75

30

30

3/8 / 5/8

50

30

30

Refer to Installation Manual

4.0

2.9

51 54

67 70

£1,163.00

£1,743.00

£2,906.00

£1,163.00

£1,245.00

£2,408.00

3.90

2728

3.21 / 3.51

A / B

1870

39 / 28

200 / 50

300

1400

700

45

40 / 33

66

Single Phase

FDQ125C

13.60

9.30

12.00

13.50

A

12.00

5.20

807

A

7.60

3.90

2728

3.21 / 3.51

A / B

1600

39 / 28

200 / 50

300

1400

700

45

40 / 33

66

3 Phase

FDQ125C

13.60

9.30

12.00

13.50

A

12.00

5.20

807

A

7.60

RZQSG125L8Y1

990 x 940 x 320

82

3ph - see notes

5.72

4

20

3/8 / 5/8

50

30

30

2.9

54

70

£1,163.00

£1,282.00

£2,445.00

-

-

3.21 / 3.41

A / B

3115

69 / 69

250 / 250

450

1400

900

89

45 / 45

81

Super Inverter (3 phase)

FDQ200B FDQ250B

-

-

-

-

19.40

16.30

20.00

23.00

-

-

-

-

-

-

23.50

20.70

25.00

27.00

-

-

-

-

2.81 / 3.21

C / C

4290

89 / 89

250 / 250

450

1400

900

94

47 / 47

82

RZQ200C

1680 x 930 x 765

183

RZQ250C

1680 x 930 x 765

3ph - see notes

184

4.61

4

25

6.35

4

25

3+E / 1.5

3/8 / 7/8

100

30

30

1/2 / 7/8

100

30

30

Refer to Installation Manual

8.3

9.3

57 57

78 78

£1,561.00

£2,576.00

£4,137.00

£1,912.00

£2,698.00

£4,610.00

Accessories:

Accessory Ref

BRC4C65

EKRORO3

KRP4A53/UK.FB2

RTD-NET/UK.FB2

RTD-10/UK.FB2

RTD-20/UK.FB2

KRCS01-4

KLIC-DI

DTA112B51

UK.CWB90-2

UK.CWB140-2

UK.DT2

UK.CGL

Description

Wireless remote controller

Remote on/off control interface kit

Unit/Group adaptor PCB for remote on/off, status indication and temperature setting

Modbus Interface PCB for Sky Air and VRV

Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock

Energy control PCB for Sky Air and VRV

Remote room mounted temperature sensor

KNX Interface for Sky Air and VRV systems

Adaptor PCB for interface to Daikin centralised control systems

Condensing unit bracket - up to size 71, max weight 90kg of ODU

Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU

Condensate drip tray for use with Sky Air ODU - tray width 1100mm

Condensing Unit Guard size 100-140 including RXYSQ

Features:

> High static units for longer ducted runs

> Up to 250Pa External Static Pressure

> Auto balancing air flow / ESP on commissioning

> Comms, computer and server room cooling possible (Seasonal Smart only)

> Super inverter technology: reduces power consumption by up to 70% compared to non inverter units

> Selectable evaporating & condensing temperature for greater operating efficiency (Seasonal Smart only)

Trade Price

£152.00

£29.00

£92.00

£190.00

£235.00

£251.00

£42.00

£185.00

£89.00

£37.00

£46.00

£59.00

£354.00

Notes:

i) All fan coils supplied as standard with

BRC1E52A wired remote controller with

7-day time clock ii) BRC4C65 Trade price will be reduced by £76.00 if ordered in place of the

BRC1E52A iii) Replacement technology not applicable to RZQ200 and RZQ250 iv) All fan coil units standard with auto restart after power failure v) All fan coils supplied as standard with air filter vi) Minimum ambient operating temperatures:

RZQG

RZQSG

RZQ

Cooling

-15°C

-15°C

-5°C

Heating

-20°C

-15°C

-15°C

vii) FDQ Fan Coil unit requires a separate

15 amp power supply

32 Residential, Commercial and Industrial

Multi Series

Multi Series Inverters offer the ability to connect up to 5 fan coils to one outdoor unit.

With the MXS range it is possible to install indoor units throughout a house or small commercial premises and only use 1 outdoor unit. Each indoor unit will have it’s own controller and will be able to operate in heating or cooling.

WI-FI

CONTR

OL

VIA APP

Heating & cooling

Connectable

Indoor Units

2MXS40H

2MXS50H

3MXS40K

3MXS52E

3MXS68G

4MXS68F

4MXS80E

5MXS90E

Wall mounted Floor standing Flexi type Round flow cassette

Fully flat cassette

Concealed ceiling Ceiling suspended

Concealed floor standing

FTXG-L CTXS-K FTXS-K FTXS-G FTX-J3 FVXG-K FVXS-F FLXS-B(9) FCQG-F FFQ-C FDXS-F(9) FDBQ-B/FBQ-D FHQ-C FNQ-A

20 25 35 50 15 35 20 25 35 42 50 60 71 20 25 35 25 35 50 25 35 50 25 35 50 60 35 50 60 25 35 50 60 25 35 50 60 25 35 50 60 35 50 60 25 35 50 60

● ● ● ● ● ● ● ●

● ● ● ● ● ● ● ● ● ● ●

● ● ● ● ● ● ● ●

● ● ● ● ● ● ● ● ● ● ●

● ● ● ● ● ● ● ● ● ● ● ●

● ● ● ● ● ● ● ● ● ● ● ●

● ● ● ● ● ● ● ● ● ● ● ● ●

● ● ● ● ● ● ● ● ● ● ● ● ●

● ● ● ● ● ● ● ●

● ● ● ● ●

● ●

● ●

● ●

● ● ●

● ●

● ●

● ● ●

● ● ● ● ● ● ●

● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

Daikin’s new Multi Selection Tool is a fast and simple way to select your combinations for MXS Series outdoor units.

The online tool has four simple steps:

> select number of rooms

> select capacity per room

> select capacity of outdoor

> select type of indoor & input pipe run & level difference

It has in-built checks to ensure capacity, pipe length and level difference cannot exceed maximum for selected outdoor unit and generates a report showing full energy label for specific combination and pictures of all equipment selected.

This can be used by installers to select Multi systems, and also to show end-users the configuration of the system.

Go to www.daikineurope.com/multiselection

Multi Split & Mini VRV Fan Coils

Emura Wall Mounted Fan Coil Units

Trade Fan Coil Unit Price

Wall Mounted Fan Coil Units

Trade Fan Coil Unit Price

Wall Mounted Low Inverter Fan Coil Units

Trade Fan Coil Unit Price

Flexi Fan Coil Units

Trade Fan Coil Unit Price

Nexura Floor Standing Fan Coil Units

Trade Fan Coil Unit Price

Floor Standing Fan Coil Units

Trade Fan Coil Unit Price

Compact Roundflow Cassette Fan Coil Units

Trade Fan Coil Unit Price

600 Sq 600 Sq 4-way blow Cassette Fan Coil Units

Trade Fan Coil Unit Price

Ceiling Suspended Fan Coil Units

Trade Fan Coil Unit Price

Ducted Fan Coil Units

Trade Fan Coil Unit Price

Slim Ducted Fan Coil Units

Trade Fan Coil Unit Price

NEW

AVAILABLE

SUMMER 2015

Vertical Chassis Unit

Trade Fan Coil Unit Price

FTXG20LW FTXG25LW FTXG35LW FTXG50LW FTXG20LS FTXG25LS FTXG35LS FTXG50LS

£262.00

£276.00

£310.00

£409.00

£313.00

£329.00

£369.00

£488.00

CTXS15K FTXS20K FTXS25K FTXS35K FTXS42K FTXS50K FTXS60G FTXS71G

£146.00

£154.00

£165.00

£189.00

£212.00

£294.00

£300.00

£400.00

FTX20J3

£123.00

FTX25J3

£136.00

FTX35J3

£154.00

FLXS25B FLXS35B9 FLXS50B

£376.00

£423.00

£459.00

FVXG25K FVXG35K FVXG50K

£631.00

£679.00

£744.00

FVXS25F FVXS35F FVXS50F

£523.00

£564.00

£616.00

FCQG35F FCQG50F FCQG60F

£ 683.00

£699.00

£743.00

FFQ25C

£636.00

FHQ35C

£668.00

FFQ35C

£696.00

FHQ50C

£722.00

FFQ50C

£766.00

FHQ60C

£792.00

FFQ60C

£809.00

FDBQ25B FBQ35D

£424.00

£515.00

FBQ50D

£541.00

FBQ60D

£600.00

FDXS25F FDXS35F FDXS50F9 FDXS60F

£394.00

£441.00

£477.00

£524.00

FNQ15A

£407.00

FNQ35A

£503.00

FNQ50A

£586.00

FNQ60A

£646.00

Notes:

i) Accessories for fan coils - refer to pair system pages ii) All fan coil units standard with auto restart after power failure iii) All fan coil units supplied as standard with remote controller iv) FDXS fan coil units supplied as standard with air filter v) 2MXS40-50H can only be used with

FTXG, FTXS, FTX, FDXS, FVXG, FVXS, FLXS fan coil units vi) One wifi adaptor per fan coil for online control

34 Residential, Commercial and Industrial

MXS-E/F/G/H/K

Multi Series Inverters

Outdoor Units

Capacity

Dimensions

Weight

Electrical Details

Nominal Cooling

Nominal Heating

Height

Width

Depth

Power Supply

Refrigerant Circuit

Running Current

Starting Current

Fuse Rating

Refrigerant Type

Sound Pressure

Sound Power

Piping Limits

Refrigerant Charge

High

Piping Connections

Maximum Length

Maximum Vertical Rise

Liquid

Gas

Number of Connected Indoor Units

Trade Condensing Unit Price

Accessories:

Accessory Ref

UK.CWB90-2

UK.DT1

UK.DT2

UK.CGM

kg dBA m m inches inches kW kW mm mm mm kg

Phase

Hz

V amps amps amps

2MXS40H

4.00

4.40

550

765

285

38

4

16

1.2

47

62

30

15

2x 1/4

2x 3/8

2

£998.00

Description

Condensing unit bracket - up to size 71, max weight 90kg of ODU

Condensate drip tray for use with Split ODU - tray width 800mm

Condensate drip tray for use with Sky Air ODU - tray width 1100mm

Condensing Unit Guard size 42-71

2MXS50H

5.00

5.70

550

765

285

42

4

16

1.6

48

63

30

15

2x 1/4

3/8 1/2

2

£1,104.00

3MXS40K

4.00

4.60

735

936

300

49

4

16

2.0

46

59

50

15

3x 1/4

2x3/8 1/2

3

3MXS52E

5.20

6.80

3MXS68G

6.80

8.60

735

936

300

49

735

936

300

58

1ph

50

230

Refer to Multi Combination Tables

4

20

4

20

R410a

2.0

46

59

50

15

3x 1/4

2x3/8 1/2

3

2.6

48

61

60

15

3x 1/4

3/8 2x1/2

3

4MXS68F

6.80

8.60

735

936

300

58

4

20

4MXS80E

8.00

9.60

770

900

320

72

4

20

5MXS90E

9.00

10.40

770

900

320

73

4

20

2.6

48

61

60

3.0

48

62

70

3.0

52

66

75

15

4x 1/4

15

4x 1/4

15

5x 1/4

2x3/8 2x1/2 3/8 1/2 2x5/8 2x3/8 1/2 2x5/8

4 4 5

£1,040.00

£1,156.00

£1,637.00

£1,766.00

£1,989.00

£2,141.00

Trade Price

£37.00

£56.00

£59.00

£296.00

Notes: i) Minimum ambient operating temperatures:

2MXS40, 50

3MXS40, 52, 68

4MXS68, 80

5MXS90

Cooling

10°C

-10°C

-10°C

-10°C

Heating

-15°C

-15°C

-15°C

-15°C

Please note: RXYSQ units are subject to VRV discount level

RXYSQ-P8

Mini VRV for Residential Applications

Outdoor Units

Capacity

Dimensions

Weight

Electrical Details

Nominal Cooling

Nominal Heating

Height

Width

Depth

Power Supply

Refrigerant Circuit

Sound Pressure

Running Current

Starting Current

Fuse Rating

Refrigerant Type

Refrigerant Charge

High

Sound Power

Piping Limits

Piping Connections

High

Maximum Length

Maximum Vertical Rise

Liquid

Gas

Capacity Index Limit

Number of Connected Indoor Units

Trade Condensing Unit Price

kW kW mm mm mm kg

Phase

Hz

V amps amps amps kg dBA dBA m m inches inches

RXYSQ4P8V1

12.60

14.20

1345

900

320

120

4

32

4.0

50

66

115 data book

3/8

5/8

50~130

8

£2,735.00

RXYSQ5P8V1

14.00

16.00

1345

900

320

120

1ph

50

230

Refer to Multi Combination Tables

4

32

R410a

4.0

51

67

135 data book

3/8

5/8

62.5~162.5

10

£3,074.00

New low height mini VRV available Summer 2015 see page 66

Accessories:

Accessory Ref

BPMKS967A2

BPMKS967A3

KHRQ22M20T

Description

Branch Provider Kit - 2 fan coil units

Branch Provider Kit - 3 fan coil units

R410a 2 Pipe Refnet Joint

Trade Price

£356.00

£380.00

£29.00

RXYSQ6P8V1

15.50

18.00

1345

900

320

120

4

32

4.0

53

69

145 data book

3/8

3/4

70~182

13

£3,431.00

Notes: i) Minimum ambient operating temperatures:

RXYSQ-P8

Cooling

-5°C

Heating

-20°C

Price List 2015 35

Possible Combinations

Twin, Triple and Double Twin Outdoor Units

Outdoor Units

RZQG71L9V1 / Y1

RZQSG71L3V1 / Y1

RZQG100L9V1 / Y1

RZQG100L9V1 / Y1

RZQSG100L9V1 / Y1

RZQSG100L9V1 / Y1

RZQG125L9V1 / Y1

RZQG125L9V1 / Y1

RZQG125L9V1 / Y1

RZQSG125L9V1 / Y1

RZQSG125L9V1 / Y1

RZQSG125L9V1 / Y1

RZQG140L9V1 / LY1

RZQG140L9V1 / LY1

RZQG140L9V1 / LY1

RZQSG140L9V1 / LY1

RZQSG140L9V1 / LY1

RZQSG140L9V1 / LY1

RZQ200

RZQ200

RZQ200

RZQ200

RZQ250

RZQ250

Nominal Cooling kW Nominal Heating kW

6.80

7.50

6.80

7.50

9.50

9.50

9.50

9.50

12.00

12.00

12.00

12.00

12.00

12.00

13.40

10.80

10.80

10.80

10.80

13.50

13.50

13.50

13.50

13.50

13.50

15.50

13.40

13.40

13.40

13.40

13.40

19.50

19.50

19.50

19.50

25.00

25.00

15.50

15.50

15.50

15.50

15.50

23.40

23.40

23.40

23.40

27.00

27.00

Possible Combinations

35 + 35

35 + 35

Model Types

FFQ, FCQG, FBQ, FDXS, FHQ, FNQ

FFQ, FCQG, FBQ, FDXS, FHQ, FNQ

50 + 50

35 + 35 + 35

50 + 50

35 + 35 + 35

FFQ, FCQG, FBQ, FDXS, FHQ, FNQ

FFQ, FCQG, FBQ, FDXS, FHQ, FNQ

FFQ, FCQG, FBQ, FDXS, FHQ, FNQ

FFQ, FCQG, FBQ, FDXS, FHQ, FNQ

60 + 60

50 + 50 + 50

FFQ, FCQG, FBQ, FDXS, FHQ, FNQ

FFQ, FCQG, FBQ, FDXS, FHQ, FNQ

35 + 35 + 35 + 35 FFQ, FCQG, FBQ, FDXS, FHQ, FNQ

60 + 60 FFQ, FCQG, FBQ, FDXS, FHQ, FNQ

50 + 50 + 50 FFQ, FCQG, FBQ, FDXS, FHQ, FNQ

35 + 35 + 35 + 35 FFQ, FCQG, FBQ, FDXS, FHQ, FNQ

71 + 71 FCQG, FCQHG, FBQ, FHQ, FUQ, FAQ

50 + 50 + 50 FFQ, FCQG, FBQ, FDXS, FHQ, FNQ

35 + 35 + 35 + 35 FFQ, FCQG, FBQ, FDXS, FHQ, FNQ

71 + 71

50 + 50 + 50

FCQG, FCQHG, FBQ, FHQ, FAQ

FFQ, FCQG, FBQ, FDXS, FHQ, FNQ

35 + 35 + 35 + 35 FFQ, FCQG, FBQ, FDXS, FHQ

100 + 100 FCQG, FCQHG, FBQ, FHQG, FUQ, FAQ

60 + 60 + 60

71 + 71 + 71

FFQ, FCQG, FBQ, FDXS, FHQ, FNQ

FCQG, FCQHG, FBQ, FHQ, FUQ, FAQ

50 + 50 + 50 + 50 FFQ, FCQG, FBQ, FDXS, FHQ, FNQ

125 + 125 FCQG, FCQHG, FBQ, FHQ, FUQ, FDQ

60 + 60 + 60 + 60 FFQ, FCQG, FBQ, FDXS, FHQ, FNQ

EXAMPLE:

Heat pump triple system using the following:

3 No FCQG71-F Fan coil units

1 No RZQ200C Condensing unit

1 No KHRQ250H7 Pipework branch kit

2 No BRC1E52A Remote controller (Credit)

TRADE EACH TRADE TOTAL

£829.00 £2,487.00

£2,578.00

£81.00

-£76.00

£2,578.00

£81.00

-£152.00

TOTAL £4,994.00

Notes:

These systems allow a mixture of fan coil types and sizes on the same condensing unit.

Each system is operated on the Master and

Slave principle from one remote controller.

As the number of possible combinations is so great, we are unable to show each system as separate prices within the price list.

To calculate a system price please refer to the next pages for individual fan coil and condensing unit prices and remember to add the pipework joints listed as accessory items on the following pages.

Each fan coil unit includes within its price for a remote controller. As a complete system requires only one controller, you will need to subtract the controller cost from all but one fan coil on each system.

* For energy labels & SEER on systems up to 12kW go to www.daikineurope.com.energylabel

Fan Coils

Twin, Triple and Double Twin Outdoor Units

Wall Mounted Fan Coil Units

Trade Fan Coil Unit Price

Ceiling Suspended Fan Coil Units

Trade Fan Coil Unit Price

Compact Roundflow Cassette Fan Coil Units

Trade Fan Coil Unit Price

High COP Roundflow Cassette Fan Coil Units

Trade Fan Coil Unit Price

600 Sq 4-way Blow Cassette Fan Coil Units

Trade Fan Coil Unit Price

Under Ceiling 4-way Blow Cassette Fan Coil Units

Trade Fan Coil Unit Price

DC Ducted Fan Coil Units

Trade Fan Coil Unit Price

Slim Ducted Fan Coil Units

Trade Fan Coil Unit Price

High Static Ducted Fan Coil Units

Trade Fan Coil Unit Price

NEW

AVAILABLE

SUMMER 2015

Vertical Chassis Unit

Trade Fan Coil Unit Price

FAQ71C FAQ100C

£749.00

£808.00

FHQ35C

£666.00

FHQ50C

£722.00

FHQ60C

£792.00

FHQ71C FHQ100C FHQ125C

£926.00

£983.00

£1,229.00

FCQG35F FCQG50F FCQG60F FCQG71F FCQG100F FCQG125F

£683.00

£699.00

£743.00

£787.00

£890.00

£972.00

FCQHG71F FCQHG100F FCQHG125F

£787.00

£890.00

£972.00

FFQ35C

£696.00

FFQ50C

£766.00

FFQ60C

£809.00

FUQ71C FUQ100C FUQ125C

£857.00

£940.00

£1,037.00

FBQ35D

£515.00

FBQ50D

£541.00

FBQ60D

£600.00

FBQ71D FBQ100D FBQ125D

£860.00

£899.00

£1,063.00

FDXS25F FDXS35F FDXS50F9 FDXS60F

£394.00

£441.00

£477.00

£524.00

FDQ125C

£1,244.00

FNQ15A

£407.00

FNQ35A

£503.00

FNQ50A

£586.00

FNQ60A

£646.00

36 Residential, Commercial and Industrial

Notes: i) Each of the fan coil units price includes one remote controller BRC1E52A ii) FBQ-D series fan coil units require a separate 1 ph power supply iii) Self cleaning deco-panel

BYCQ140DG is compatible on cassettes used in twin, triple and double twin applications iv) For seasonal data on Twin,

Triple and Double Twin applications please consult www.daikineurope.com/ energylabel

v) Accessories for fan coils and condensing units - refer to pair system pages

RZQG

Seasonal Smart Inverter

Outdoor Units

Dimensions Height

Width

Depth

Weight

Electrical Details Power Supply

Running Current

Starting Current

Max Fuse Size

Interconnection Wiring Core / Cable size

Piping Connections

Pipework

Sound Pressure

Sound Power mm mm mm kg

A

A

A

Liquid / Gas

Maximum Length inches m

Maximum Vertical Rise m

Precharged to m

Additional Charge

Holding Charge

High g/m kg dBA

Trade Condensing Unit Price

Accessories:

Accessory Ref

KHRQ22M20T

KHRQ127H

KHRQ250H7

UK.CWB90-2

UK.CWB140-2

UK.DT2

UK.CGM

UK.CGL

RZQG

71L9V1

990

940

320

78

4

20

3/8 / 5/8

50

2.9

48

64

Seasonal Smart Inverter

Single Phase

RZQG

100L9V1

1430

940

320

102

1ph data book

4

32

RZQG

125L9V1

1430

940

320

102

4

32

RZQG

140L9V1

1430

940

320

102

4

32

RZQG-

71L8Y1

Seasonal Smart Inverter

3 Phase

RZQG-

100L8Y1

3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8

75 75 75 50 75

30

30

4.0

50

66

4.0

51

67

4.0

52

69

Refer to Installation Manual

2.9

4.0

48

64

50

66

RZQG-

125L8Y1

990

940

320

80

4

16

3+E / 1.5

1430

940

320

101

3ph data book

1430

940

320

101

4

20

4

20

4.0

51

67

RZQG-

140LY1

1430

940

320

101

4

20

4.0

52

69

Super Inverter

RZQ200C

1680

930

765

183

4

25

8.3

57

78

3ph

RZQ250C

data book

1680

930

765

184

4

25

3/8 / 5/8 3/8 / 5/8 3/8 / 7/8 1/2 / 7/8

75 75 100 100

9.3

57

78

£1,191.00 £1,514.00 £1,666.00 £1,901.00 £1,227.00 £1,584.00 £1,743.00 £2,002.00 £2,576.00 £2,698.00

Notes:

i) Accessories for fan coils and condensing units - refer to pair system pages

Description

R410a 2 Pipe Refnet Joint

Triple Refnet Joint - RZQS71~140,RZQ100~140

Triple Refnet Joint - RZQ200~250

Condensing unit bracket - up to size 71, max weight 90kg of ODU

Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU

Condensate drip tray for use with Sky Air ODU - tray width 1100mm

Condensing Unit Guard size 42-71

Condensing Unit Guard size 100-140 including RXYSQ

Trade Price

£29.00

£65.00

£81.00

£37.00

£46.00

£59.00

£296.00

£354.00

RZQSG

Seasonal Classic Inverter

Outdoor Units

Dimensions

Weight

Height

Width

Depth mm mm mm kg

Electrical Details

Sound Pressure

Sound Power

Power Supply

Running Current

Starting Current

Max Fuse Size

A

A

A

Interconnection Wiring Core / Cable size

Piping Connections

Pipework

Liquid / Gas

Maximum Length inches m

Maximum Vertical Rise m

Precharged to

Additional Charge m g/m

Holding Charge

High kg dBA

Trade Condensing Unit Price

Accessories:

Accessory Ref

KHRQ22M20T

KHRQ127H

KHRQ250H7

UK.CWB90-2

UK.CWB140-2

UK.DT2

UK.CGM

UK.CGL

Seasonal Classic Inverter Seasonal Classic Inverter

Single Phase 3 Phase

RZQSG71L3V1 RZQSG100L9V1 RZQSG125L9V1 RZQSG140L9V1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1

770

900

320

67

4

20

3/8 / 5/8

50

2.75

49

65

990

940

320

81

4

32

3/8 / 5/8

50

2.9

53

69

990

940

320

81

1430

940

320

102

1ph data book

4

32

3/8 / 5/8

50

2.9

54

70

4

32

3+E / 1.5

3/8 / 5/8

50

30

30

Refer to Installation Manual

4.0

53

69

990

940

320

82

4

20

3/8 / 5/8

50

2.9

53

69

990

940

320

82

3ph data book

4

20

3/8 / 5/8

50

2.9

54

70

1430

940

320

101

4

20

3/8 / 5/8

50

4.0

53

69

£820.00

£1,135.00

£1,245.00

£1,386.00

£ 1,170.00

£1,282.00

£1,428.00

Notes:

i) Accessories for fan coils and condensing units - refer to pair system pages

Description

R410a 2 Pipe Refnet Joint

Triple Refnet Joint - RZQS71~140,RZQ100~140

Triple Refnet Joint - RZQ200~250

Condensing unit bracket - up to size 71, max weight 90kg of ODU

Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU

Condensate drip tray for use with Sky Air ODU - tray width 1100mm

Condensing Unit Guard size 42-71

Condensing Unit Guard size 100-140 including RXYSQ

Trade Price

£29.00

£65.00

£81.00

£37.00

£46.00

£59.00

£296.00

£354.00

Price List 2015 37

CYVS/M/L - BC

Air curtains are the ideal solution to combat the issue of climate separation across retail outlets or office doorways.

In conjunction with Biddle, Daikin ERQ heat pump air curtain solution combines the benefits of the Biddle air curtain technology with the benefits of Daikin ERQ heat pump inverter technology.

Using a combination of rectifier technology, air velocity and temperature control they deliver greater comfort to staff and customers alike, all year round, in all weathers.

BIDDLE AIR CURTAINS & ERQ PAIRS ARE LISTED ON ECA –

For product listing refer to: https://etl.decc.gov.uk/etl/site/etl.html

Features and benefits:

> Energy savings up to 72% compared with electric air curtains

> Short payback times – less than 1.5 years

> Wide capacity range for maximum application potential plus flexible control options

> R-410A refrigerant, single and 3 phase

> Wide operation range: -20~15.5°C in heating

> Air curtain rectifier technology – deep penetrating airstream

> Constant air velocity technology – all year round efficiency

> European patent

> 1.0, 1.5, 2.0 and 2.5 metre door widths

> Door heights of up to 3.7 metres

> Choice of colour RAL9010:White or RAL9006:Grey

F = Free hanging model C = Cassette model R = Recessed model

Biddle Comfort air curtain range

4m

3.7m

2.7m

3.2m

2.8m

3.1m

3m

2m

1m

2.35m

2.0m

2.3m

2.5m

Selection

1) Use the Door Height graph to determine the Air Curtain size relevant to your application

2) When you know the size (S/M/L), refer to specific tables to select the model for your required door width

3) Select Outdoor unit to pair door curtain, based on efficiency and power source

S M L

Ideal for doors in a shopping centre or revolving door entrance

S M L

Installation condition

For more exposed doors with some direct wind, suitable for ground floor applications

S M L

For areas exposed to higher wind speeds i.e. open stairwell or balcony door at higher than ground level

S

Biddle Standard Air Curtain (Small) –

Door height 2m to 2.7m

Maximum Door Width

Mounting Height *2 Max / Min

Model Name

Type

Heating Capacity

m m

Delta T Inlet = room temperature speed 3 k

Power Input (50Hz) Fan only / Heating kW

Dimensions Height

Width speed 3 kW mm mm

Depth

Weight

Casing Colour

Minimum requiring ceiling void

Fan - Air Flow Rate Heating speed 3 mm kg mm m

3

/sec speed 3 dBA Sound Pressure

Refrigerant

Heating

Type

Piping Connections Liquid (OD) / Gas

Power Supply mm ph/V/Hz

Trade Unit Price

* = F

270

1,500

590

66

1.50

2.7 / 2.0

CYQS150DK80*BN

* = C

9.00

15

0.35 / 0.35

270

1,500

821

83 white RAL9010

420

0.485

49

R-410A

9.52/16.0

1~/230/50

* = R

270

1,548

561

88

* = F

270

2,000

590

83

2.00

2.7 / 2.0

CYQS200DK100*BN

* = C

11.60

15

0.46 / 0.46

270

2,000

821

102 white RAL9010

420

0.647

50

R-410A

9.52/16.0

1~/230/50

* = R

270

2,048

561

108

* = F

270

2,500

590

107

2.50

2.7 / 2.0

CYQS250DK140*BN

* = C

16.20

16

0.58 / 0.58

270

2,500

821

129 white RAL9010

420

0.808

51

R-410A

9.52/19.0

1~/230/50

* = R

270

2,548

561

137

£2,908.00

£2,908.00

£3,065.00

£3,538.00

£3,538.00

£3,836.00

£3,972.00

£3,972.00

£4,299.00

* 2: Mounting Height at base of Door Curtain Air Outlet. F = Free Hanging / C = Cassette / R = Recessed

Condensing Unit Selection for Small Door Curtain

Standard Efficiency

Improved Efficiency

High Efficiency

ERQ100AV1

ERQ100 AV1

ERQ125AV1 / AW1

ERQ125AV1 / AW1

ERQ140AV1

ERQ200AV1

38 Residential, Commercial and Industrial

M

Biddle Standard Air Curtain (Medium) –

Door height 2.3m to 3.2m

Maximum Door Width

Mounting Height *2 Max / Min

Model Name

Type

Heating Capacity

m m

speed 3 kW

Delta T Inlet = room temperature speed 3 k

Power Input (50Hz) Fan only / Heating kW

Dimensions Height

Width mm mm

Depth

Weight

Casing Colour

Minimum requiring ceiling void mm kg

Fan - Air Flow Rate

Sound Pressure

Refrigerant

Heating

Heating

Type mm speed 3 m

3

/sec speed 3 dBA

Piping Connections Liquid (OD) / Gas

Power Supply mm ph/V/Hz

Trade Unit Price

CYQM100DK80*BN

* = F

1.00

3.2 / 2.3

* = C

9.20

0.446

50

R-410A

9.52/16.0

1~/230/50

* = R

270

1,000

590

57

17

0.37 / 0.37

270

1,000

821

68 white RAL9010

420

270

1,048

561

66

1.50

3.2 / 2.3

CYQM150DK80*BN

* = F * = C

11.00

* = R

270

1,500

590

73

14

0.56 / 0.56

270

1,500

821

88 white RAL9010

420

270

1,548

561

93

0.669

51

R-410A

9.52/16.0

1~/230/50

CYQM200DK100*BN

* = F

2.00

3.2 / 2.3

* = C

13.40

0.892

53

R-410A

9.52/16.0

1~/230/50

* = R

270

2,000

590

94

13

0.75 / 0.75

270

2,000

821

111 white RAL9010

420

270

2,048

561

117

* = F

2.5

3.2 / 2.3

CYQM250DK140*BN

* = C

19.90

* = R

270

2,500

590

108

15

0.94 / 0.94

270

2,500

821

136 white RAL9010

420

270

2,548

561

144

1.115

54

R-410A

9.52/19.0

1~/230/50

£2,820.00 £2,820.00 £2,910.00 £3,360.00 £3,360.00 £3,515.00 £4,207.00 £4,207.00 £4,504.00 £4,816.00 £4,816.00 £5,137.00

* 2: Mounting Height at base of Door Curtain Air Outlet. F = Free Hanging / C = Cassette / R = Recessed

Condensing Unit Selection form Medium Door Curtain

Standard Efficiency

Improved Efficiency

High Efficiency

ERQ100AV1

ERQ100AV1

ERQ125AV1 / AW1

ERQ100AV1

ERQ125AV1 / AW1

ERQ140AV1

ERQ200AW1

ERQ250AW1

L

Biddle Standard Air Curtain (Large) –

Door height 2.5m to 3.7m

Maximum Door Width

Mounting Height *2 Max / Min

Model Name

Type

Heating Capacity

m m

speed 3 kW

Delta T Inlet = room temperature speed 3 k

Power Input (50Hz) Fan only / Heating kW

Dimensions Height

Width mm mm

Depth

Weight

Casing Colour

Minimum requiring ceiling void mm kg

Fan - Air Flow Rate

Sound Pressure

Refrigerant

Heating

Heating

Type mm speed 3 m

3

/sec speed 3 dBA

Piping Connections Liquid (OD) / Gas

Power Supply mm ph/V/Hz

Trade Unit Price

CYQL100DK125*BN

* = F

1.00

3.7 / 2.5

* = C

15.60

0.861

53

R-410A

9.52/16.0

1~/230/50

* = R

370

1,000

774

76

15

0.75 / 0.75

370

1,000

1105

81 white RAL9010

520

370

1,048

745

83

1.50

3.7 / 2.5

CYQL150DK200*BN

* = F * = C

23.30

* = R

370

1,500

774

100

15

1.13 / 1.13

370

1,500

1105

118 white RAL9010

520

370

1,548

745

141

1.292

54

R-410A

9.52/19.0

1~/230/50

CYQL200DK250*BN

* = F

2.00

3.7 / 2.5

* = C

29.40

1.722

56

R-410A

9.52/22.0

1~/230/50

* = R

370

2,000

774

126

14

1.50 / 1.50

370

2,000

1105

151 white RAL9010

520

370

2,048

745

155

* = F

2.5

3.7 / 2.5

CYQL250DK250*BN

* = C

31.10

* = R

370

2,500

774

157

12

1.88 / 1.88

370

2,500

1105

190 white RAL9010

520

370

2,548

745

196

2.153

57

R-410A

9.52/22.0

1~/230/50

£3,217.00 £3,217.00 £3,226.00 £4,589.00 £4,589.00 £4,737.00 £5,697.00 £5,697.00 £5,993.00 £6,649.00 £6,649.00 £7,016.00

* 2: Mounting Height at base of Door Curtain Air Outlet. F = Free Hanging / C = Cassette / R = Recessed

Condensing Unit Selection for Large Door Curtain

Standard Efficiency

Improved Efficiency

High Efficiency

ERQ125AV1 / AW1

ERQ140AV1

ERQ200AW1

ERQ200AW1

ERQ250AW1

ERQ250AW1 ERQ250AW1

ERQ Condensing Units

Dimensions

Weight

Pipe Run

Airflow Direction

Trade Unit Price

Height

Width

Depth mm mm mm kg mm

ERQ100AV1

1135

900

320

120

55

Side blow

£1,533.00

Single Phase

ERQ125AV1

1135

900

320

120

55

Side blow

£1,709.00

Accessories for all Door Curtains

Accessory Ref

BRC1E52A

KRCS01-1

RTD-20/UK.FB2

Description

Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock

Remote room mounted temperature sensor

Energy control PCB for Sky Air and VRV

ERQ140AV1

1135

900

320

120

55

Side blow

£2,049.00

ERQ125AW1

1680

635

765

159

55

Top blow

£1,743.00

Trade Price

£76.00

£46.00

£251.00

3 Phase

ERQ200AW1

1680

930

765

187

55

Top blow

£3,271.00

ERQ250AW1

1680

930

765

240

55

Top blow

£3,408.00

Notes: i) To calculate the price for a complete system, add together the prices for door curtain, ERQ and remote controller.

1 off CYQL100DK125FBN

1 off ERQ125AV1

1 off BRC1E52

Total

£4,021.00

£1,709.00

£76.00

£5,806.00

Price List 2015 39

Central Ducted Solutions

For central ducted distribution systems

Daikin has the solution for providing cooling and heating of the air, enabling optimal comfort and efficiency.

Liquid pipe

Gas pipe

EV kit

Even without the benefit of individual room control, the system can provide a flexible energy saving answer over traditional methods through the incorporation of inverter control and heat pump technology.

The following pages include Packaged Heat Pump Rooftop systems, with optional economisers, to heat pump condensing units and connection kits for use with other manufacturers heating and cooling coils.

Air handling unit

Liquid pipe

Gas pipe

Field supply

F1,F2 communication

Control box

DDC control

(control w)

Air Cooled Heat Pump Inverter

Condensing Unit Kit for DX Coil

A range of R410a inverter condensing units for application with air handling units:

> Inverter controlled heat pump units

> Large capacity range (from 6.3 to 61.6 kW)

> Ventilation and air conditioning in 1 solution

> EKEXV-kit & control boxes are designed for outdoor installation and can be wall mounted

> Per EKEXV-kit/control box, only 1 air handling unit coil can be connected

> Outdoor unit operation range: -5°CDB ~ 43°CDB in cooling

> For connectivity to VRV IV systems, please consult with your local

Daikin representative

Flexible control possibilities:

Control w:

Full external control from 3rd party temperature controller with volt free remote enable contact and linear variable capacity control output (3rd party DDC Controller required).

Control y:

External control from 3rd party temperature controller with volt free remote enable contact. Fixed evaporating temperature selection, range: +3°C to +10°C.

Control z (BRC1D52 required):

Control via Daikin BRC1D52 remote controller and return air or remote sensor (KRCS01-1 optional). A volt free remote enable contact is required to confirm fan operation status. For re-circ applications only.

Outdoor unit

1ph ERQ100AV1

ERQ125AV1

ERQ140AV1

3ph ERQ125AW1

ERQ200AW1

ERQ250AW1

Trade

Unit Price

£1,533.00

£1,709.00

£2,049.00

£1,743.00

£3,271.00

£3,408.00

Control box control z control y, w control y, w class 63 class 80 class 100

Expansion Valve Kit class 125 class 140 class 200 class 250 class 400 class 500

EKEQDCB EKEQFCBA EKEQMCBA EKEXV63 EKEXV80 EKEXV100 EKEXV125 EKEXV140 EKEXV200 EKEXV250 EKEXV400 EKEXV500

P

P

P

P

P

P

P

P

P

P

P

P

VRV only

P

P

-

P

-

-

P

P

P

P

-

-

P

P

P

P

P

-

P

P

P

P

P

P

-

P

P

P

P

P

-

-

-

-

P

P

-

-

-

-

P

P

VRV only VRV only

Trade Acc. Price £313.00

£361.00

P: Pair Combination depending on air handling units coils volume

£557.00

£70.00

£72.00

£79.00

£86.00

£99.00

£118.00

£132.00

For all AHU application selections with ERQ and VRV systems,

please consult with a member of Daikin staff to ensure correct selection and AHU coil design parameters.

£146.00

£160.00

40 Residential, Commercial and Industrial

ERAD-E

Large Condensing Units

Capacity

EER

Refrigerant

Dimensions

Nominal Cooling

Length

Height

Width

Weight

Electrical Details Power Supply kW

V

Hz mm mm mm kg ph

Trade Unit Price

Large Condensing Unit (Standard Noise Level)

ERAD120E-SS ERAD140E-SS ERAD170E-SS ERAD200E-SS ERAD220E-SS ERAD250E-SS ERAD310E-SS ERAD370E-SS ERAD440E-SS ERAD490E-SS

121

2.89

144

2.82

165

2.87

196

3.01

219

2.97

252

3.29

306

3.3

370

3.03

435

2.96

488

3.03

R134a

2170

2.27

1290

1564

2170

2.27

1290

1587

3070

2.27

1290

1698

3070

2.27

1290

1739

3070

2.27

1290

1886

3070

2.27

1290

1928

3070

2220

2240

2355

3070

2220

2240

2559

3070

2220

2240

2642

3070

2220

2240

2677

400

50

3

POA POA POA POA POA POA POA POA POA POA

Capacity

EER

Refrigerant

Dimensions

Nominal Cooling

Length

Height

Width

Weight

Electrical Details Power Supply kW mm mm mm kg

V

Hz ph

Trade Unit Price

Large Condensing Unit (Low Noise Level)

ERAD120E-SL ERAD140E-SL ERAD160E-SL ERAD190E-SL ERAD210E-SL ERAD240E-SL ERAD300E-SL ERAD350E-SL ERAD410E-SL ERAD460E-SL

116

2.74

137

2.61

159

2.76

187

2.82

209

2.83

243

3.11

295

3.22

352

2.88

409

2.72

462

2.76

R134a

2170 2170 3070 3070 3070 3070 3070 3070 3070 3070

2.27

1290

1712

2.27

1290

1738

2.27

1290

1851

2.27

1290

1897

2.27

1290

2046

2.27

1290

2091

2220

2240

2534

2220

2240

2741

2220

2240

2834

2220

2240

2873

400

50

3

POA POA POA POA POA POA POA POA POA POA

Features:

ERAD-E are a range of cooling only R134a condensing units for pair application with air handling units

> Large capacity range 100 kW to 410 kW

> Superior control logic using the new MicroTech III controller

> Single circuit units

> Screw compressor with capacity control down to 25%

> Available in both standard and low noise configurations

Please contact your sales office for further information on these products

UATYQ

Rooftop Packaged Unit – Heat Pump

Capacity

Dimensions

Nominal Cooling kW

Nominal Heating kW

Height

Width mm mm

Weight

Air Flow Rate

External Static

Air Flow Rate

Refrigerant

Sound Power Level Outdoor

Drain size

Electrical Details

Depth

Indoor

Indoor

Outdoor

Power Supply mm kg m

Pa m

Running Current A

Starting Current A

Max Fuse Size A

3

3

/min

/min dBA mm

V

Hz

Phase

Trade Unit Price

Economiser

Trade Unit Price

UATYQ250CY1 UATYQ350CY1 UATYQ450CY1 UATYQ550CY1 UATYQ600CY1 UATYQ700CY1 UATYPC10AY1 UATYPC12AY1

27.34

35.58

44.72

55.69

66.82

72.60

101.10

109.60

24.91

1150

1638

34.79

1028

2209

41.79

1130

2209

53.93

1048

2209

61.69

1302

2209

69.61

1302

2209

102.30

1974

2252

126.30

1974

2252

2063

445

93

147

0

2113

580

122

147

0

2113

610

160

147

0

2670

830

190

206

0

2670

880

205

206

0

2670

1020

233

206

0

3180

1510

312

0

3180

1600

354

0

R410a R407C

82 83 83 87 90 90 80 80

25.4 (OD)

400

50

3ph

20.5

118

32

£5,027.00

26.4

93

40

£5,234.00

33.1

123

40

£8,612.00

39.4

137

50

£9,476.00

41.6

144

50

£10,190.00

46.5

148

50

£10,904.00

74.2

175 , 215

125

£14,559.00

82.9

215x2

125

£15,816.00

ECONO250AY1 ECONO350AY1 ECONO450AY1 ECONO550AY1 ECONO600AY1 ECONO700AY1

£886.00

£931.00

£976.00

£1,024.00

£1,076.00

£1,129.00

Notes: i) Minimum Ambient operating conditions

UATYQ250~700

UATYPC10~12

Cooling

0°C

20°C

Heating

-15°C

-15°C ii) Supplied with remote controller as standard iii) Economiser option is supplied as a kit for site assembly iv) Low ambient kit for models UATYPC available on request v) Please check stock & delivery period for all model sizes vi) Standard delivery for all units does not include off-loading to kerbside vii) UATYQ250/350 can be off-loaded by fork-lift if there is one on site viii) All other units require crane or HIAB. Prices for HIAB available on request

Price List 2015 41

Daikin UK Price List 2015

VRV

Indoor Units

44

VRV Fan Coil Units

Air Curtains

44

52

Hot Water Connection 54

Outdoor Condensing Units

57

VRV Condensing Units – Heat Recovery 57

VRV Condensing Units – Heat Pump

VRV Condensing Units – Heat Pump Mini

62

66

VRV Condensing Units – Replacement VRV-Q 69

Accessories

77

VRV Unit Accessories

Intelligent Controls

Scotland

Region

0845 641 9330

Northern

Region

0845 641 9340

Midlands

Region

0845 641 9370

Western

Region

0845 641 9320

North

London

0845 641 9360

South

London

0845 641 9355

FXFQ-A

VRV Fan Coil – Roundflow Cassette

Indoor unit

Cooling capacity

Heating capacity

Power input - 50Hz

Dimensions

Weight

Decoration panel

Nom.

Nom.

Cooling

Heating

Unit

Unit

Model

Nom.

Nom.

H x W x D kW kW kW kW mm kg

Decoration panel 2

Colour

Dimensions H x W x D

Weight

Model

Colour

Dimensions H x W x D

Weight

Model mm kg mm kg

Decoration panel 3

Colour

Dimensions H x W x D

Weight

Fan-Air flow rate - 50Hz Cooling mm kg

High/Nom./Low m³/min

Sound power level

Heating

Cooling

High/Nom./Low m³/min

High/Nom.

dBA

Sound pressure level

Refrigerant

Piping connections

Power supply

Current - 50Hz

Cooling

Heating

Type

High/Nom./Low

High/Nom./Low

Liquid/OD/Gas/OD/Drain

Phase/Frequency/Voltage

Maximum fuse amps (MFA) dBA dBA mm

Hz/V

A

FXFQ20A FXFQ25A

2.2

2.8

2.5

3.2

0.038

0.038

19

FXFQ32A FXFQ40A

3.6

4.5

4.0

5.0

FXFQ50A

5.6

6.3

0.053

0.053

FXFQ63A

7.1

8.0

0.061

0.061

204x840x840

20 21

Roundflow BYCQ140D (standard panel)

Pure White (RAL 9010)

60x950x950

5.4

Roundflow with white louvres BYCQ140DW

Pure White (RAL 9010)

60x950x950

5.4

Roundflow self cleaning BYCQ140DG

12.5/10.6/8.8

12.5/10.6/8.8

49/-

FXFQ80A FXFQ100A FXFQ125A

9.0

10.0

0.092

24

11.2

12.5

0.115

0.092

0.115

246x840x840

14.0

16.0

0.186

0.186

288x840x840

26

Pure White (RAL 9010)

145x950x950

10.3

13.6/11.6/9.5 15.0/12.8/10.5 16.5/13.5/10.5 22.8/17.6/12.4 26.5/19.5/12.4 33.0/26.5/19.9

13.6/11.6/9.5 15.0/12.8/10.5 16.5/13.5/10.5 22.8/17.6/12.4 26.5/19.5/12.4 33.0/26.5/19.9

51/53/55/60/61/-

31/29/28

31/29/28

6.35/12.7/VP25 (O.D. 32 / I.D. 25)

33/31/29

33/31/29

R-410A

1~/50/ 220-240

16

35/33/30

35/33/30

38/34/30

38/34/30

43/37/30

43/37/30

9.52/15.9/VP25 (O.D. 32 / I.D. 25)

45/41/36

45/41/36

Trade Unit Price £759.00

£774.00

£792.00

£855.00

£897.00

£946.00

£1,009.00

£1,095.00

£1,365.00

Notes: i) Cassette prices include standard decoration panel - self cleaning panel available as an accessory item ii) BYCQ140D7W1 = pure white panel with grey louvers , BYCQ140D7W1W = pure white standard panel with white louvers, BYCQ140D7GW1 = Pure white auto cleaning panel

The BYCQ140D7W1W has white insulations. Be informed that formations of dirt on white insulation is visibly stronger & that it is consequently not advised to install the decoration panel in environments exposed to concentrations of dirt iii) For accessories please refer to pages 77 - 86

FXZQ-A

VRV Fan Coil – 600 Sq 4 Way Blow Cassette

Indoor unit

Cooling capacity

Heating capacity

Power input - 50Hz

Dimensions

Weight

Decoration panel

Nom.

Nom.

Cooling

Heating

Unit

Unit

Model

Nom.

Nom.

H x W x D kW kW kW kW mm kg

Decoration panel 2

Colour

Dimensions H x W x D

Weight

Model

Colour

Dimensions H x W x D

Weight

Model mm kg mm kg

Decoration panel 3

Colour

Dimensions H x W x D

Weight

Fan-Air flow rate - 50Hz Cooling mm kg

High/Nom./Low m³/min

Sound power level

Sound pressure level

Refrigerant

Piping connections

Power supply

Current - 50Hz

Heating

Cooling

Cooling

Heating

High/Nom./Low m³/min

High/Nom.

dBA

High/Nom./Low dBA

High/Nom./Low dBA

Type

Liquid/OD/Gas/OD/Drain

Phase/Frequency/Voltage

Maximum fuse amps (MFA) mm

Hz/V

A

Trade Unit Price

FXZQ15A

1.7

1.9

FXZQ20A

2.2

2.5

0.043

0.036

8.5/7/6.5

8.5/7/6.5

31.5/28/25.5

31.5/28/25.5

8.7/7.5/6.5

8.7/7.5/6.5

49/-

32/29.5/25.5

32/29.5/25.5

£721.00

15.5

£737.00

FXZQ25A

2.8

FXZQ32A

3.6

3.2 4.0

0.045

0.038

260x575x575

16.5

Fully Flat in white BYFQ60CW (standard panel)

White (N9.5)

46x620x620

2.8

Fully flat in white with silver BYFQ60CS

White (N9.5) + Silver

46x620x620

2.8

Old style panel BYFQ60B3

White (RAL9010)

55x700x700

2.7

9/8/6.5

10/8.5/7

9/8/6.5

50/-

33/30/25.5

33/30/25.5

10/8.5/7

51/-

33.5/30/26

33.5/30/26

R-410A

6.35/12.7/VP20 (I.D. 20/O.D. 26)

1~/50/220-240

16

£752.00

£769.00

Notes: i) Cassette prices include Fully Flat decoration panel in fresh white. Other colour panels available on request. ii) Dimensions include control box iii) For accessories please refer to pages 77 - 86

FXZQ40A

4.5

5.0

0.059

0.053

11.5/9.5/8

11.5/9.5/8

54/-

37/32/28

37/32/28

£825.00

44 Residential, Commercial and Industrial

FXZQ50A

5.6

6.3

0.092

0.086

18.5

14.5/12.5/10

14.5/12.5/10

60/-

43/40/33

43/40/33

£906.00

FXCQ-A

VRV Fan Coil – 2 Way Blow Cassette

Indoor unit

Cooling capacity

Heating capacity

Power input - 50Hz

Casing

Dimensions

Weight

Decoration panel

Nom.

Nom.

Cooling

Heating

Material

Unit

Unit

Model

Colour

Nom.

Nom.

H x W x D kW kW kW kW mm kg

Dimensions H x W x D

Weight

Fan-Air flow rate - 50Hz Cooling mm kg

High/Nom./Low m³/min

Sound power level

Sound pressure level

Cooling

Cooling

Heating

Nom.

High/Nom./Low

High/Nom./Low dBA dBA dBA

Refrigerant

Piping connections

Air filter

Power supply

Current - 50Hz

Type

Liquid/OD/Gas/OD/Drain

Type

Phase/Frequency/Voltage

Maximum fuse amps (MFA) mm

Hz/V

A

FXCQ20A

2.2

2.5

0.031

0.028

FXCQ25A

2.8

3.2

0.039

0.035

19

FXCQ32A

305x775x620

BYBCQ40HW1

3.6

4.0

FXCQ40A

4.5

5.0

0.041

FXCQ50A

5.6

6.3

0.059

FXCQ63A

7.1

8.0

0.063

0.037

0.056

Galvanised steel plate

0.060

305x990x620

22

BYBCQ63HW1

25

Fresh white (6.5Y 9.5/0.5)

FXCQ80A

9.0

10.0

0.090

0.086

FXCQ125A

14.0

16.0

0.149

0.146

305x1,445x620

33 38

BYBCQ125HW1

10.5/9/7.5

55x1,070x700

10

11.5/9.5/8 12/10.5/8.5

55x1,285x700

11

15/13/10.5

16/14/11.5

-

32.0/30.0/28.0 34.0/31.0/29.0 34.0/32.0/30.0 36.0/33.0/31.0 37.0/35.0/31.0 39.0/37.0/32.0 42.0/38.0/33.0 46.0/42.0/38.0

32.0/30.0/28.0 34.0/31.0/29.0 34.0/32.0/30.0 36.0/33.0/31.0 37.0/35.0/31.0 39.0/37.0/32.0 42.0/38.0/33.0 46.0/42.0/38.0

R-410A

55x1,740x700

13

26/22.5/18.5

32/27.5/22.5

6.35/12.7/VP25 (O.D. 32 / I.D. 25) 9.52/15.9/VP25 (O.D. 32 / I.D. 25)

Resin net with mold resistance

1~/50/220-240

16

Trade Unit Price £854.00

£869.00

£878.00

£970.00

£1,061.00

£1,102.00

£1,265.00

£1,518.00

Notes: i) Cassette prices include decoration panel ii) For accessories please refer to pages 77 - 86

FXKQ-MA

VRV Fan Coil – 1 Way Blow Corner Cassette

Indoor unit

Cooling capacity

Heating capacity

Power input - 50Hz

Dimensions

Weight

Decoration panel

Nom.

Nom.

Cooling

Heating

Unit

Unit

Model

Colour

Nom.

Nom.

H x W x D

Dimensions H x W x D

Weight

Fan-Air flow rate - 50Hz Cooling

Sound power level Cooling

High/Low

Nom.

Sound pressure level

Refrigerant

Piping connections

Power supply

Current - 50Hz

Cooling

Type

High/Low

Liquid/OD/Gas/OD/Drain

Phase/Frequency/Voltage

Maximum fuse amps (MFA) kW kW kW kW mm kg mm kg m³/min dBA dBA mm

Hz/V

A

FXKQ25MA

2.8

3.2

FXKQ32MA

3.6

4.0

0.066

0.046

215x1,110x710

31

BYK45FJW1

White

70x1,240x800

8.5

11/9

-

38.0/33.0

R-410AR-410A

6.35/12.7/VP25 (O.D. 32 / I.D. 25)

1~/50/ 220-240

15

FXKQ40MA

4.5

5.0

0.076

0.056

13/10

40.0/34.0

Trade Unit Price £946.00

£956.00

£1,045.00

Notes: i) Cassette prices include decoration panel ii) For accessories please refer to pages 77 - 86

FXKQ63MA

7.10

8.00

0.105

0.085

215x1,310x710

34

BYK71FJW1

70x1,440x800

9.5

18/15

42.0/37.0

9.52/15.9/VP25 (O.D. 32 / I.D. 25)

£1,185.00

Price List 2015 45

FXHQ-A

VRV Fan Coil – Ceiling Suspended

Indoor unit

Cooling capacity

Heating capacity

Piping connections

Power supply

Current - 50Hz

Nom.

Nom.

Power input - 50Hz Cooling

Heating

Casing Colour

Dimensions

Weight

Unit

Unit

Fan-Air flow rate - 50Hz Cooling

Sound power level

Sound pressure level

Refrigerant

Heating

Cooling

Cooling

Heating

Type

Nom.

Nom.

H x W x D

Liquid/OD/Gas/OD/Drain

Phase/Frequency/Voltage

Maximum fuse amps (MFA) kW kW kW kW mm kg

High/Nom./Low m³/min

High/Nom./Low m³/min

Nom.

dBA

High/Nom./Low dBA

High/Nom./Low dBA mm

Hz/V

A

Trade Unit Price

FXHQ32A

3.6

4.0

0.107

0.107

235x960x690

24

14.0/12.0/10.0

14.0/12.0/10.0

36.0/34.0/31.0

36.0/34.0/31.0

6.35/12.7/VP20 (I.D. 20/O.D. 26)

£906.00

Notes: i) For accessories please refer to pages 77 - 86

FXHQ63A

7.1

8.0

0.111

0.111

Fresh White

235x1,270x690

33

20.0/17.0/14.0

20.0/17.0/14.0

-

37.0/35.0/34.0

37.0/35.0/34.0

R-410A

9.52/15.9/VP20 (I.D. 20/O.D. 26)

1~/50/220-240

16

FXHQ100A

11.2

12.5

0.237

0.237

235x1,590x690

39

29.5/24.0/19.0

29.5/24.0/19.0

44.0/37.0/34.0

44.0/37.0/34.0

£1,004.00

£1,246.00

FXUQ-A

VRV Fan Coil – Under Ceiling Cassette

Indoor unit

Cooling capacity

Heating capacity

Power input - 50Hz

Nom.

Nom.

Cooling

Heating

Casing Colour

Dimensions

Weight

Unit

Unit

Fan-Air flow rate - 50Hz Cooling

Sound power level

Sound pressure level

Refrigerant

Piping connections

Power supply

Current - 50Hz

Nom.

Nom.

kW kW kW kW

H x W x D mm kg

High/Nom./Low m³/min

Heating

Cooling

Cooling

Heating

High/Nom./Low m³/min

Nom.

dBA

High/Nom./Low dBA

High/Nom./Low dBA

Type

Liquid/OD/Gas/OD/Drain

Phase/Frequency/Voltage

Maximum fuse amps (MFA) mm

Hz/V

A

Trade Unit Price

FXUQ71A

8.0

9.0

0.090

0.073

26

22.5/19.5/16.0

22.5/19.5/16.0

40.0/38.0/36.0

40.0/38.0/36.0

£1,254.00

Notes: i) For accessories please refer to pages 77 - 86

Fresh White

198x950x950

-

R-410A

9.52/15.9/I.D. 20/O.D. 26

1~/50/ 220-240

16

FXUQ100A

11.2

12.5

0.200

0.179

27

31.0/26.0/21.0

31.0/26.0/21.0

47.0/44.0/40.0

47.0/44.0/40.0

£1,337.00

46 Residential, Commercial and Industrial

FXDQ-M9

VRV Fan Coil – Small Ducted

Indoor unit

Cooling capacity

Heating capacity

Nom.

Nom.

Power input - 50Hz Cooling

Heating

Casing Colour

Dimensions Unit

Required ceiling void >

Weight Unit

Fan-Air flow rate - 50Hz Cooling

Sound power level

Sound pressure level

Heating

Cooling

Cooling

Heating

Refrigerant

Piping connections

Power supply

Current - 50Hz

Nom.

Nom.

H x W x D

High/Low

High/Low

Nom.

High/Low

High/Low

Type

Liquid/OD/Gas/OD/Drain

Phase/Frequency/Voltage

Maximum fuse amps (MFA)

Trade Unit Price

kW kW kW kW mm mm kg m³/min m³/min dBA dBA dBA mm

Hz/V

A

Notes: i) For accessories please refer to pages 77 - 86 ii) Fan coils supplied as standard with factory fitted filter

FXDQ20M9

2.2

2.5

6.7/5.2

6.7/5.2

£579.00

0.050

0.050

Unpainted

230x502x652

250

17

50

37/32

37/32

R-410A

6.35/12.7/I.D. 21.6, O.D. 27.2

1~/50/230

16

FXDQ25M9

2.8

3.2

7.4/5.8

7.4/5.8

£597.00

FXDQ-A

VRV Fan Coil – Slim Ducted

Indoor unit

Cooling capacity

Heating capacity

Power input - 50Hz

Nom.

Nom.

Cooling

Heating

Casing Colour

Dimensions

Required ceiling void >

Weight

Unit

Unit

Fan-Air flow rate - 50Hz Cooling

Fan-External static pressure - 50Hz

High/Nom.

Sound power level

Sound pressure level

Refrigerant

Piping connections

Nom.

Nom.

H x W x D kW kW kW kW mm mm kg

High/Nom./Low m³/min

Pa

Cooling

Cooling

Nom.

dBA

High/Nom./Low dBA

Type

Liquid/OD/Gas/OD/Drain mm

Power supply

Current - 50Hz

Trade Unit Price

Phase/Frequency/Voltage

Maximum fuse amps (MFA)

Hz/V

A

FXDQ15A

1.7

1.9

7.5/7.0/6.4

50

32/31/27

£562.00

Notes: i) For accessories please refer to pages 77 - 86 ii) Fan coils supplied as standard with factory fitted filter

FXDQ20A

2.2

2.5

0.071

0.068

FXDQ25A

2.8

3.2

FXDQ32A

3.6

4.0

FXDQ40A

Galvanised steel / Non painted

4.5

5.0

0.078

0.075

200x750x620

FXDQ50A

200x950x620

5.6

6.3

0.099

0.096

240

22

30/10

8.0/7.2/6.4

10.5/9.5/8.5

FXDQ63A

7.1

8.0

0.110

0.107

200x1,150x620

26 29

12.5/11.0/10.0

16.5/14.5/13.0

44/15

52

34/32/28

53

35/33/29

51

33/31/27

R-410A

6.35/12.7/VP20

(I.D. 20/O.D. 26)

1~/50/ 220-240

16

54

36/34/30

9.52/15.9/VP20

(I.D. 20/O.D. 26)

£579.00

£597.00

£605.00

£644.00

£670.00

£691.00

Price List 2015 47

NEW

AVAILABLE

SPRING 2015

Indoor Units

Nominal Cooling

Nominal Heating

Air Flow Rate High

Low

External Static Pressure High

Low

Dimensions Height x Width x Depth

Weight

Electrical Details Power Supply

Sound Level

Piping Connections

FXSQ-A

VRV Fan Coil – Concealed Ceiling Unit (High Static)

Running Current

Fuse Rating

Sound Pressure High

Low

Sound Power

Liquid

Gas kg

Phase

Hz

V

W amps dBA dBA dBA inches inches kW kW m 3 /sec m 3 /sec

Pa

Pa mm

FXSQ15A FXSQ20A FXSQ25A FXSQ32A FXSQ40A FXSQ50A FXSQ63A FXSQ80A FXSQ100A FXSQ125A FXSQ140A

1.7

2.2

2.8

3.6

4.5

5.6

7.1

9 11.2

14 16

1.9

2.5

3.2

4 5 6.3

8 10 12.5

16 18

0.145

0.1

150

30

23.5

0.15

0.15

150

30

0.15

0.15

150

30

245 x 550 x 800

23.5

23.5

0.158

0.15

150

30

24

0.25

0.25

150

30

0.25

0.25

150

30

245 x 700 x 800

28.5

0.35

0.35

150

30

245 x 1000 x 800

35.5

0.38

0.38

150

40

36.5

0.46

0.46

150

40

0.61

0.61

150

50

0.65

0.65

150

50

245 x 1400 x 800 245 x 1550 x 800

46 47 51 29

1ph

50

230

41

29.5

25

54

1/4

1/2

41

30

25

54

1/4

1/2

41

30

25

54

1/4

1/2

45

31

26

55

1/4

1/2

92

35

29

60

1/4

1/2

60

1/4

1/2

95

5

35

29

95

33

27

59

3/4

5/8

121

35

29

61

3/4

5/8

157

36

31

61

3/4

5/8

214

39

33

64

3/4

5/8 tbc

44 tbc tbc

3/4

5/8

Trade Unit Price £580.00 £598.00 £614.00 £622.00 £662.00 £690.00 £712.00 £812.00 £900.00 £1,030.00 £1,133.00

Notes: i) For accessories please refer to pages 77 - 86 ii) Preliminary Data – May be subject to change

FXMQ-P7

VRV Fan Coil – High Static Ducted

Indoor Units

Capacity UK Total Cooling

UK Sensible Cooling

UK Heating

Nominal Cooling

Air Flow Rate

Nominal Heating

High

Low

External Static pressure High

Low

Dimensions

Weight

Electrical Details

Height x Width x Depth

Power Supply

Sound Level

Piping Connections

Trade Unit Price

Running Current

Fuse Rating

Sound Pressure High

Low

Sound Power

Liquid

Gas mm kg

Phase

Hz

V amps amps dBA dBA dBA inches kW kW kW kW kW m

3

/sec m

3

/sec

Pa

Pa inches

FXMQ50P7

4.50

4.10

6.30

5.60

6.30

0.30

0.25

200.0

100.0

35

1.4

41.0

37.0

61/-

1/4

1/2

£1,066.00

FXMQ63P7

5.70

4.90

8.00

7.10

8.00

0.33

0.27

200.0

100.0

300 x 1000 x 700

35

1.4

42.0

38.0

64/-

3/8

5/8

£1,117.00

Notes: i) For accessories please refer to pages 77 - 86

FXMQ80P7

7.20

6.10

10.00

9.00

10.00

0.42

0.33

200.0

100.0

1.7

5

43.0

39.0

35

1ph

50

230

67/-

3/8

5/8

£1,174.00

FXMQ100P7

9.00

7.30

12.50

11.20

12.50

0.53

0.38

200.0

100.0

300 x 1400 x 700

FXMQ125P7

11.30

9.20

16.00

14.00

16.00

0.65

0.47

200.0

100.0

46 46

2.3

43.0

39.0

65/-

3/8

5/8

£1,301.00

2.9

44.0

40.0

70/-

3/8

5/8

£1,489.00

48 Residential, Commercial and Industrial

FXMQ-MA

VRV Fan Coil – High Static Ducted

Indoor Units

Capacity UK Total Cooling

UK Sensible Cooling

UK Heating

Nominal Cooling

Nominal Heating

High Air Flow Rate

Low

External Static pressure High

Low

Height x Width x Depth Dimensions

Weight

Electrical Details Power Supply

Sound Level

Piping Connections

Running Current

Fuse Rating

Sound Pressure High

Low

Sound Power

Liquid

Gas kW kW kW kW kW m 3 /sec m

3

/sec

Pa

Pa mm kg

Phase

Hz

V amps amps dBA dBA dBA inches inches

Trade Unit Price

FXMQ200MA

18.00

14.90

25.00

22.40

25.00

0.97

0.83

221.0

132.0

137

6.5

48.0

45.0

-

3/8

3/4

£2,601.00

Notes: i) For accessories please refer to pages 77 - 86

470 x 1380 x 1100

1ph

50

230

13

FXMQ250MA

22.50

18.50

31.50

28.00

31.50

1.20

1.03

270.0

147.0

137

7.2

48.0

45.0

-

3/8

7/8

£2,662.00

FXAQ-P

VRV Fan Coil – Wall Mounted

Indoor unit

Cooling capacity

Heating capacity

Power input - 50Hz

Refrigerant

Piping connections

Nom.

Nom.

Cooling

Heating

Casing Colour

Dimensions

Weight

Unit

Unit

Fan-Air flow rate - 50Hz Cooling

Sound power level

Sound pressure level

Cooling

Cooling

Nom.

Nom.

H x W x D

High/Low

Nom.

High/Low

Type

Liquid/OD/Gas/OD/Drain

Power supply

Current - 50Hz

Trade Unit Price

Phase/Frequency/Voltage

Maximum fuse amps (MFA) kW kW kW kW mm kg m³/min dBA dBA mm

Hz/V

A

FXAQ15P

1.7

1.9

0.017

0.025

7.0/4.5

34.0/29.0

£439.00

Notes: i) For accessories please refer to pages 77 - 86

FXAQ20P FXAQ25P FXAQ32P FXAQ40P

2.2

2.5

0.019

0.029

290x795x238

11

7.5/4.5

2.8

3.2

0.028

0.034

3.6

4.0

0.030

0.035

4.5

5.0

0.020

0.020

White (3.0Y8.5/0.5)White (3.0Y8.5/0.5)

8/5 12/9

35.0/29.0

36.0/29.0

8.5/5.5

-

37.5/29.0

39.0/34.0

R-410A

6.35/12.7/VP13

(I.D. 13/O.D. 18)

1~/50/220-240

16

£452.00

£464.00

£469.00

£481.00

FXAQ50P

5.6

6.3

0.033

0.039

290x1,050x238

14

15/12

42.0/36.0

FXAQ63P

7.1

8.0

0.050

0.060

19/14

47.0/39.0

9.52/15.9/VP13

(I.D. 13/O.D. 18)

£507.00

£559.00

Price List 2015 49

FXLQ-P

VRV Fan Coil – Floor Mounted Cased

Indoor unit

Cooling capacity

Heating capacity

Nom.

Nom.

Power input - 50Hz Cooling

Heating

Casing Colour

Dimensions

Weight

Unit

Unit

Fan-Air flow rate - 50Hz Cooling

Sound power level

Sound pressure level

Refrigerant

Piping connections

Power supply

Nom.

Nom.

H x W x D

Cooling

Cooling

High/Low

Nom.

High/Low

Type

Liquid/OD/Gas/OD/Drain

Phase/Frequency/Voltage

Current - 50Hz Maximum fuse amps (MFA)

Trade Unit Price

kW kW kW kW mm kg m³/min dBA dBA mm

Hz/V

A

FXLQ20P

2.2

2.5

0.049

0.049

FXLQ25P

2.8

3.2

600x1,000x232

27

7/6

35/32

£695.00

£706.00

FXLQ32P

3.6

4.0

0.090

0.090

Fresh white (RAL9010) / Dark grey (RAL7011)

600x1,140x232

32

8/6 11/8.5

-

R-410A

6.35/12.7/O.D. 21

1~/50/ 220-240

38/33

15

FXLQ40P

4.5

5.0

£720.00

£746.00

Notes: i) For accessories please refer to pages 77 - 86

FXLQ50P

5.6

6.3

0.110

0.110

FXLQ63P

7.1

8.0

14/11

600x1,420x232

38

16/12

39/34 40/35

9.52/15.9/O.D. 21

£754.00

£799.00

NEW

AVAILABLE

SUMMER 2015

Indoor Units

Capacity

Air Flow Rate

Dimensions

Weight

Electrical Details

Sound Level

Piping Connections

Trade Unit Price

FXNQ-A

VRV Fan Coil – Vertical Chassis Unit

Nominal Cooling

Nominal Heating

High

Low

Height x Width x Depth

Power Supply

Running Current

Fuse Rating

Sound Pressure High

Low

Liquid

Gas kW kW m 3 /sec m 3 /sec mm kg

Phase

Hz

V amps amps dBA dBA inches inches

FXNQ20A

2.2

2.5

0.13

10.6

22 tbc tbc tbc

1/4

1/2

FXNQ25A

2.8

3.2

0.13

10.6

620 x 750 x 200

22 tbc tbc tbc

1/4

1/2

FXNQ32A

3.6

4

0.13

10.6

22 tbc tbc tbc

1/4

1/2

1ph

50

230

5

FXNQ40A

4.5

5

FXNQ50A

5.6

6.3

0.175

0.14

620 x 950 x 200

26

0.21

0.166

26 tbc tbc tbc

1/4

1/2

£697.00

tbc tbc tbc

1/4

1/2

£704.00

£649.00

£659.00

£673.00

Increased static pressure – up to 44Pa

Notes: i) For accessories please refer to pages 77 - 86 ii) Preliminary Data – May be subject to change

FXNQ63A

7.1

8

0.275

0.216

620 x 1350 x 200

29 tbc tbc tbc

3/8

5/8

£748.00

50 Residential, Commercial and Industrial

AVAILABLE

UP TO

SUMMER 2015

Indoor Units

Capacity

Air Flow Rate

Dimensions

Weight

Electrical Details

Sound Level

Piping Connections

FXNQ-P

VRV Fan Coil – Floor Mounted Chassis

UK Total Cooling

UK Sensible Cooling

UK Heating

Nominal Cooling

Nominal Heating

High

Low

Height x Width x Depth

Power Supply

Running Current

Fuse Rating

Sound Pressure

Sound Power

Liquid

Gas

High

Low kW kW amps amps dBA dBA dBA inches inches kW kW kW m 3 /sec m

3

/sec mm kg

Phase

Hz

V

FXNQ20P

1.80

1.50

2.50

2.20

2.50

0.12

0.10

610 x 930 x 220

FXNQ25P

2.30

1.80

3.20

2.80

3.20

0.12

0.10

19 19

0.2

35.0

32.0

-

1/4

1/2

£618.00

0.2

35.0

32.0

-

1/4

1/2

£628.00

FXNQ32P

2.90

2.20

4.00

3.60

4.00

0.13

0.10

610 x 1070 x 220

FXNQ40P

3.60

2.70

5.00

4.50

5.00

0.18

0.14

23 23

1ph

50

230

0.5

0.5

5

35.0

32.0

-

1/4

1/2

38.0

33.0

-

1/4

1/2

£641.00

£664.00

Trade Unit Price

Notes: i) For accessories please refer to pages 77 - 86

FXNQ50P

4.50

3.40

6.30

5.60

6.30

0.23

0.18

610 x 1350 x 220

FXNQ63P

5.70

4.20

8.00

7.10

8.00

0.27

0.20

27 27

0.5

39.0

34.0

-

1/4

1/2

£670.00

0.5

40.0

35.0

-

3/8

5/8

£712.00

AVAILABLE

UP TO

SUMMER 2015

UK.FXDQ

VRV Fan Coil – Low Level Wall Mounted

Chassis (Medium Static)

Indoor Units

Capacity

Air Flow Rate

UK Total Cooling

UK Sensible Cooling

UK Heating

Nominal Cooling

Nominal Heating

High

Dimensions

Weight

Nom

Low

External Static Pressure High

Low

Height

Electrical Details Power Supply

Running Current

Fuse Rating

Sound Pressure Sound Level

Piping Connections

Sound Power

Liquid

Gas

Trade Unit Price

Notes: i) For accessories please refer to pages 77 - 86

Hi Hi

High

Low kW kW kW kW kW m

3

/sec m 3 /sec m 3 /sec

Pa

Pa mm kg

Phase

Hz

V amps amps dBA dBA dBA dBA inches inches

UK.FXDQ15A

UK.FXDQ20A

UK.FXDQ25A

UK.FXDQ32A

1.40

1.30

1.70

1.70

1.70

0.13

0.12

0.11

30.0

10.0

22

1.80

1.60

2.50

2.20

2.50

0.13

0.12

0.11

30.0

10.0

2.30

1.90

3.20

2.80

3.20

0.13

0.12

0.11

30.0

10.0

22

620 x 700 x 200

22

2.90

2.20

4.00

3.60

4.00

0.13

0.12

0.11

30.0

10.0

0.3

0.3

0.3

22

1ph

50

230

0.3

32.0

31.0

29.0

-

1/4

1/2

33.0

31.0

29.0

-

1/4

1/2

33.0

31.0

29.0

-

1/4

1/2

5

33.0

31.0

29.0

-

1/4

1/2

£793.00

£810.00

£828.00

£836.00

UK.FXDQ40A

UK.FXDQ50A

UK.FXDQ63A

3.60

2.80

5.00

4.50

5.00

0.18

4.50

3.50

6.30

5.60

6.30

0.21

5.70

4.30

8.00

7.10

8.00

0.28

0.16

0.14

44.0

15.0

26

620 x 950 x 200

26

0.18

0.17

44.0

15.0

0.24

0.22

44.0

15.0

620 x 1150 x 200

29

0.4

34.0

32.0

28.0

-

1/4

1/2

£875.00

0.4

35.0

33.0

29.0

-

1/4

1/2

£901.00

0.5

36.0

34.0

30.0

-

3/8

5/8

£922.00

Price List 2015 51

CYVS/M/L - DK - F/C/R

Air curtains are the ideal solution to combat the issue of climate separation across retail outlets or office doorways.

In conjunction with Biddle, Daikin VRV IV heat recovery air curtain solution combines the benefits of the Biddle air curtain technology with the benefits of Daikin VRV IV heat recovery.

Using a combination of rectifier technology, air velocity and temperature control they deliver greater comfort to staff and customers alike, all year round, in all weathers.

Easy and fast installation of these systems not only reduces costs but makes expensive water systems, boilers and gas connections redundant. Integrating a Biddle air curtain with Daikin VRV also eliminates the need to install multiple outdoor units thereby reducing installation time and costs further. This combination enables Daikin to offer its customers the ultimate environmentally conscious TOTAL SOLUTION PACKAGE comprising cooling, heating, outdoor-indoor climate separation and fresh air ventilation.

Some air curtains may be ECA compliant please see

ECA website for details www.daikin.co.uk/ECA

Features and benefits:

> Provides virtually free air curtain heating via recovered heat from indoor units in cooling mode

> Connection to the high COP heat recovery system enables COP’s of up to 4.36

> Short payback times – less than 3 years

> Air curtain rectifier technology – deeply penetrating airstream

> Constant air velocity technology – all year round efficiency

> European patent

> 1.0, 1.5, 2.0 and 2.5 metre door widths

> Door heights of up to 3.7 metres

> Choice of colour RAL9010:White or RAL9006:Grey

F = Free hanging model C = Cassette model R = Recessed model

Biddle Comfort air curtain range

4m

3m

2.7m

3.2m

3.7m

2.35m

2.8m

3.1m

2.0m

2.3m

2.5m

2m

1m

S M L

Ideal for doors in a shopping centre or revolving door entrance

S M L

Installation condition

For more exposed doors with some direct wind, suitable for ground floor applications

S M L

For areas exposed to higher wind speeds i.e. open stairwell or balcony door at higher than ground level

52 Residential, Commercial and Industrial

Selection

1) Use the Door Height graph to determine the Air Curtain size relevant to your application

2) When you know the size (S/M/L), refer to specific tables to select the model for your required door width

CYVS/M/L - DK - F/C/R

S

Small air curtains:

Maximum Door Width

Mounting Height *2

Model name

Type

Heating capacity

Delta T speed 3 kW

Inlet = room temperature speed 3 kW

Power input (50Hz) Fan only / Heating

Dimensions Height kW mm

Width

Depth mm mm

Weight kg

Casing Colour

Minimum requiring ceiling void

Fan - Air flow rate

Sound pressure

Refrigerant

Heating

Heating

Type

Piping connections Liquid (OD) / Gas

Power supply mm speed 3 m 3 speed 3

/sec dBA mm ph/V/Hz

1.0

CYVS100DK80*BC

* = F * = C * = R

270

1,000

590

56

7.40

15

0.23/0.23

270

1,000

891

59

270

1,048

561

61 white RAL9010

420

0.323

47

R-410A

9.52/16.0

1~/230/50

1.5

2.0

2.7 / 2.0

CYVS150DK80*BC

* = F * = C * = R

CYVS200DK100*BC

* = F * = C * = R

270

1,500

590

66

9.00

15

0.35/0.35

270

1,500

821

83

270

1,548

561

88

270

2,000

590

83

11.60

15

0.46/0.46

270

2,000

821

102

270

2,048

561

108 white RAL9010

420

0.485

49

R-410A

9.52/16.0

1~/230/50 white RAL9010

420

0.647

50

R-410A

9.52/16.0

1~/230/50

2.5

CYVS250DK140*BC

* = F * = C * = R

270

2,500

590

107

16.20

16

0.58/0.58

270

2,500

821

129

270

2,548

561

137 white RAL9010

420

0.808

51

R-410A

9.52/19.0

1~/230/50

Trade Unit Price £2,486.00 £2,456.00 £2,560.00 £3,167.00 £3,136.00 £3,311.00 £3,827.00 £3,798.00 £4,103.00 £4,270.00 £4,240.00 £4,575.00

M

Medium air curtains:

Maximum Door Width

Mounting Height *2

Model name

Type

Heating capacity

Delta T Inlet = room temperature speed 3 kW

Power input (50Hz) Fan only / Heating kW

Dimensions Height mm

Fan - Air flow rate

Width

Depth

Weight

Casing Colour

Minimum requiring ceiling void

Heating speed 3 mm mm kg mm m

3

/sec

Sound pressure

Refrigerant

Heating

Type

Piping connections Liquid (OD) / Gas

Power supply speed 3 kW speed 3 dBA mm ph/V/Hz

Trade Unit Price

1.0

CYVM100DK80*BC

* = F * = C * = R

9.20

17

0.37/0.37

270 270

1,000

590

57

1,000

891

68 white RAL9010

420

270

1,048

561

66

0.446

50

R-410A

9.52/16.0

1~/230/50

1.5

2.0

3.2 / 2.3

CYVM150DK80*BC

* = F * = C * = R

CYVM200DK100*BC

* = F * = C * = R

11.00

14

0.56/0.56

270 270

1,500

590

73

1,500

821

88 white RAL9010

420

270

1,548

561

93

0.669

51

R-410A

9.52/16.0

1~/230/50

270

2,000

590

94

13.40

13

0.75/0.75

270

2,000

821

111 white RAL9010

420

0.892

53

R-410A

9.52/16.0

1~/230/50

270

2,048

561

117

2.5

CYVM250DK140*BC

* = F * = C

19.90

15

0.94/0.94

270 270

2,500

590

108

2,500

821

136 white RAL9010

420

1.115

54

R-410A

9.52/19.0

1~/230/50

* = R

270

2,548

561

144

£2,844.00 £2,813.00 £2,919.00 £3,644.00 £3,613.00 £3,773.00 £4,514.00 £4,484.00 £4,788.00 £5,137.00 £5,108.00 £5,436.00

L

Large air curtains:

Maximum Door Width

Mounting Height *2

Model name

Type

Heating capacity

Delta T

Power input (50Hz) Fan only / Heating speed 3 kW

Inlet = room temperature speed 3 kW kW

Dimensions Height

Width

Depth

Weight

Casing Colour

Minimum requiring ceiling void

Fan - Air flow rate Heating speed 3 mm mm mm kg mm m

3

/sec speed 3 dBA Sound pressure

Refrigerant

Heating

Type

Piping connections Liquid (OD) / Gas

Power supply mm ph/V/Hz

Trade Unit Price

1.0

CYVM100DK80*BC

* = F * = C * = R

9.20

17

0.37/0.37

270

1,000

590

57

270

1,000

891

68 white RAL9010

420

270

1,048

561

66

0.446

50

R-410A

9.52/16.0

1~/230/50

1.5

2.0

3.7 / 2.5

CYVM150DK80*BC

* = F * = C * = R

CYVM200DK100*BC

* = F * = C * = R

11.00

14

0.56/0.56

270

1,500

590

73

270

1,500

821

88 white RAL9010

420

270

1,548

561

93

0.669

51

R-410A

9.52/16.0

1~/230/50

270

2,000

590

94

13.40

13

0.75/0.75

270

2,000

821

111 white RAL9010

420

0.892

53

R-410A

9.52/16.0

1~/230/50

270

2,048

561

117

2.5

CYVM250DK140*BC

* = F * = C

19.90

15

0.94/0.94

270

2,500

590

108

270

2,500

821

136 white RAL9010

420

1.115

54

R-410A

9.52/19.0

1~/230/50

* = R

270

2,548

561

144

£3,623.00 £3,585.00 £3,696.00 £4,820.00 £4,783.00 £4,932.00 £5,935.00 £5,897.00 £6,193.00 £6,892.00 £6,855.00 £7,219.00

Accessories:

Accessory Ref

BRC1E52A

KRCS01-1

RTD-20/UK.FB2

Description

Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock

Remote room mounted temperature sensor

Energy control PCB for Sky Air and VRV

Trade Price

£76.00

£46.00

POA

Notes: i) Biddle Remote Controller and connection cable included for Fan Speed Control ii) If RTD-20 Connected in Air Curtain mode the

Biddle Remote Controller is NOT connected as Fan speed is managed by RTD-20 iii) Code “BC” is for white finish. Aluminium finish “SC”available on request

Price List 2015 53

HXHD-A / HXY-A

Hot water generation – VRV heat recovery systems

Producing hot water from a heat recovery VRV system is one of the most energy efficient means of providing hot water within a building. We can provide high and low temperature hot water for bathrooms, toilet wash basins, underfloor heating, radiators and even provide heated water for air handling unit applications.

Using waste heat to provide hot water means you can provide an additional service to your building from the heat recovery VRV system at very low cost.

Features and benefits:

For both low temperature and high temperature

> Uses heat pump technology to produce hot water efficiently, providing up to 17% savings compared to a gas boiler

> Saves time on system design as all water-side components are fully integrated with direct control over leaving water temperature

> Requires no gas connection or oil tank

HXHD-A (High temperature) HXY-A (Low temperature)

For low temperature

> Highly efficient space heating/cooling

> Leaving water temperature range from 5°C to 45°C without electric heater

> Super wide operating range for cold/hot water production from

-20 to +43°C ambient outdoor temperature

> Saves space with contemporary wall hung design

For high temperature

> Possibility to connect thermal solar collectors to the domestic hot water tank

> Leaving water temperature range from 25 to 80°C without electric heater

> Various control possibilities with weather dependant set point or thermostat control

VRV heat recovery with connection to heating only hydrobox (REYQ-T)

BS-Box

VRV indoor units

45°C - 75°C

EKHTSU-AC

EKHWP-B

25°C - 75°C

BS-Box

Heating only hydrobox for VRV

45°C - 75°C

25°C - 35°C

Domestic hot water

Air handling unit

Low temp. radiator

Under floor heating

Liquid pipe

Gas pipe

Discharge gas pipe

Hot/cold water

Hot/cold water

BS-Box

HXY-A Low temperature hydrobox

54 Residential, Commercial and Industrial

HXHD-A / HXY-A

Hot water generation – VRV heat recovery systems

Indoor unit

Cooling Capacity

Heating capacity

Casing

Dimensions

Weight

Sound pressure level

Operation range

Refrigerant

Refrigerant circuit

Water circuit

Power supply

Current

Trade Unit Price

Nom.

Nom.

Colour

Material

Unit

Unit

Nom.

Night quiet mode

Heating

H xW xD

Level 1

Ambient

Water side

Min.~Max.

Min.~Max.

Domestic hot water

Type

Gas side diameter

Liquid side diameter

Piping connections diameter

Heating water system

Phase/Frequency/Voltage

Water volume Min.~Max.

Recommended fuses

Ambient

Water side

Min.~Max.

Min.~Max.

kW kW mm kg dBA dBA

°C

°C

°CDB

°C mm mm l inch

Hz/V

A

HXHD125A

High Temperature

-

14.0

Metallic grey

705x600x695

92

42 (1) / 43 (2)

38 (1)

-20~20 / 24 (3)

25~80

-20~43

45~75

R-134a

12.7

9.52

G 1” (female)

20~200

1~/50/220-240

20

£2,713.00

HXY080A

Low Temperature

8

9

White

Precoated sheet metal

890x480x344

44

HXY125A

12.5

14

-

-20~24

25~45

-

-

R-410A

15.9

9.5

G 1” 1/4(female)

-

1~/50/220-240

6~16

£1,461.00

£2,050.00

(1) Sound levels are measured at: EW 55°C; LW 65°C (2) Sound levels are measured at: EW 70°C; LW 80°C (3) Field setting

Notes: i) Hydroboxes are connectable to the following outdoor series only: Air Cooled Heat Recovery REYQ-T (see page 57) ii) Hydroboxes are inclusive of integral expansion vessel, and pump

EKHTSU

HT Water Tank

Domestic Unvented Hot Water Tank

Water Volume

Max Water Temperature

Height

Width

Depth

Empty Weight

Colour

Material Inside Tank

Material Outside Casing

Piping Connections

(Diameter)

Water inlet H/E

Water outlet H/E

Cold Water in

Hot water out

Trade Unit Price

l

°C mm mm mm kg inch inch inch inch

EKHTSU200AC EKHTSU260AC

Unvented System (Includes EKUHWHT unvented Kit as shown below)

200 260

75

1335

600

695

81

1610

600

695

89

Metallic grey

Stainless Steel

Precoated sheet metal

3/4 "

3/4 "

3/4 "

3/4 "

£1,121.00

£1,269.00

Accessories:

Accessories For Unvented Systems

EKUHWHT Includes: Combined Pressure Reducing Valve, Non Return Valve, Strainer, Expansion Relief Valve,

Expansion Vessel, Tundish

EKFMAHTB Option for stand alone tank (ie not mounted on top of hydrobox)

Trade Unit Price

Included with

EKHTSU*AC

£277.00

Notes: i) Hydroboxes are connectable to the following outdoor series only: Air Cooled

Heat Recovery REYQ-T (see page 57) ii) Hydroboxes are inclusive of integral expansion vessel and pump

Price List 2015 55

HXY-A

Hot water generation – VRV heat pump systems

Producing hot water from a heat pump system provides extremely low cost heating and cooling of water.

Temperatures between 5°C to 45°C can be achieved allowing water temperature control for multiple applications without the need for a separate system.

HXY-A

Features and benefits:

> Highly efficient space heating/cooling

> Air to water connection to VRV for applications such as underfloor, AHU, low temperature radiators

> Leaving water temperature range from 5°C to 45°C without electric heater

> Super wide operating range for cold/hot water production from

-20 to +43°C ambient outdoor temperature

> Saves time on system design as all water-side components are fully integrated with direct control over leaving water temperature

> Saves space with contemporary wall hung design

> Requires no gas connection or oil tank

Liquid pipe

Gas pipe

Hot/cold water

VRV indoor units

Air handling unit

VRV IV heat pump

Low temp. radiator

HXY-A Low temperature hydrobox

Under floor heating

Indoor unit

Cooling capacity

Heating capacity

Casing

Dimensions

Weight

Sound pressure level

Operation range

Refrigerant

Refrigerant circuit

Water circuit

Power supply

Recommended fuses

Trade Unit Price

Nom.

Nom.

Colour

Material

Unit

Unit

Nom.

Heating

H x W x D

Ambient

Water side

Type

Gas side diameter

Liquid side diameter

Piping connections diameter

Phase/Frequency/Voltage

Min.~Max.

Min.~Max.

kW kW mm kg dBA

°C

°C mm mm inch

Hz/V

A

56 Residential, Commercial and Industrial

HXY080A

8

9

White

Precoated sheet metal

890x480x344

44

-

-20~24

25~45

R-410A

15.9

9.5

G 1”1/4 (female)

1~/50/220-240

6~16

HXY125A

12.5

14

£1,461.00

£2,050.00

The VRV Total Solution

Many buildings today typically operate quite separate systems for heating, cooling, refrigeration and hot water. As a result, a huge amount of energy is wasted. To provide a much more efficient alternative, VRV technology has been developed into a total solution for heating, cooling, refrigeration and ventilation.

The VRV total solution

Air conditioning, refrigeration and cooling IT servers can generate masses of waste heat that can be reused to heat and ventilate other areas of the building or to provide hot water for wash rooms, at a much reduced cost.

By understanding the whole building’s heating and cooling needs at the outset, an integrated climate control solution can be delivered that offers much higher energy efficiency levels, thus reducing the carbon impact of a building. This means that all internal and external conditions must be taken into account in the design of the climate control system.

REYQ-T (8 to 12 HP)

VRV IV Condensing Units – Heat Recovery

Outdoor Units

Capacity Nominal Cooling

Nominal Heating

Height x Width x Depth Dimensions

Weight

Fan

Electrical Details

Air Flow Rate

Power Supply

Running Current

Starting Current

Fuse Rating

Refrigerant Circuit Refrigerant Type

Refrigerant Charge

Additional Charge

Sound Pressure

Sound Power

Piping Limits

Piping Connections -

Systems

Maximum Total Length

Maximum Actual Length

Gas

Liquid

Discharge

Capacity Index Limit

Maximum Number of Connected Indoor Units

Trade Condensing Unit Price

kg kg dBA dBA m m inches inches inches kW kW mm kg m

3

/sec

Phase amps amps amps

8 HP Single

REYQ8T

22.40

22.40

1685 x 930 x 765

198

2.70

8.9

20 data book

58

78

3/4

3/8

5/8

100 ~ 260

64

£4,984.00

10 HP Single

REYQ10T

28.00

28.00

1685 x 930 x 765

205

2.92

11.8

25 data book

58

79

7/8

3/8

3/4

125 ~ 325

64

£5,475.00

10 HP Multi

REMQ5T

28.00

28.00

1685 x 930 x 765

198

2.70

3ph / 50 Hz / 380~415V

5.3

4

20

R410A data book

REMQ5T

1685 x 930 x 765

198

2.70

20 data book

58

78

1000

165

58

78

7/8

3/8

3/4

125 ~ 325

64

£6,840.00

12 HP Single

REYQ12T

33.50

33.50

1685 x 930 x 765

205

3.08

15.3

25 data book

61

81

1 1/8

1/2

3/4

150 ~ 390

64

£6,639.00

Price List 2015 57

REYQ-T (13 to 16 HP)

VRV IV Condensing Units – Heat Recovery

Outdoor Units

Capacity Nominal Cooling

Nominal Heating

Height x Width x Depth Dimensions

Weight

Fan

Electrical Details

Air Flow Rate

Power Supply

Running Current

Starting Current

Fuse Rating

Refrigerant Circuit Refrigerant Type

Refrigerant Charge

Additional Charge

Sound Pressure

Sound Power

Piping Limits

Piping Connections -

Systems

Maximum Total Length

Maximum Actual Length

Gas

Liquid

Discharge

Capacity Index Limit

Maximum Number of Connected Indoor Units

Trade Condensing Unit Price

kg kg dBA dBA m m inches inches inches kW kW mm kg m

3

/sec

Phase amps amps amps

REYQ8T

13 HP Multi

REMQ5T

1685 x 930 x 765

198

2.70

36.40

33.50

1685 x 930 x 765

198

2.70

8.9

20

5.3

20

58

78 data book

1 1/8

1/2

3/4

162.5 ~ 422.5

64

£8,404.00

58

78

14 HP Single

REYQ14T

40.00

40.00

45.00

45.00

1685 x 1240 x 765 1685 x 1240 x 765 1685 x 930 x 765

319 319 198

3.72

4.33

3ph / 50 Hz / 380~415V

2.70

45.00

45.00

1685 x 930 x 765

198

2.70

17.4

21.1

8.9

4

32 40 20 20

R410A

16 HP Single

REYQ16T REYQ8T

16 HP Multi

REYQ8T

data book data book data book data book

61

81

64

86

58

78

58

78

1000

165

1 1/8

1/2

7/8

175 ~ 455

64

1 1/8

1/2

7/8

200 ~ 520

64

1 1/8

1/2

7/8

200 ~ 520

64

£7,827.00

£9,224.00

£9,968.00

REYQ-T (18 to 20 HP)

VRV IV Condensing Units – Heat Recovery

Outdoor Units

Capacity Nominal Cooling

Nominal Heating

Height x Width x Depth Dimensions

Weight

Fan

Electrical Details

Refrigerant Circuit

Air Flow Rate

Power Supply

Running Current

Starting Current

Fuse Rating

Refrigerant Type

Refrigerant Charge

Additional Charge

Sound Pressure

Sound Power

Piping Limits

Piping Connections -

Systems

Maximum Total Length

Maximum Actual Length

Gas

Liquid

Discharge

Capacity Index Limit

Maximum Number of Connected Indoor Units

Trade Condensing Unit Price

kg kg dBA dBA m m inches inches inches kW kW mm kg m

3

/sec

Phase amps amps amps

18 HP Single

REYQ18T REYQ8T

18 HP Multi

REYQ10T

50.00

51.00

1685 x 1240 x 765 1685 x 930 x 765

329 198

4.18

2.70

51.00

51.00

1685 x 930 x 765

205

2.92

56.00

56.00

1685 x 1240 x 765

329

4.35

3ph / 50 Hz / 380~415V

1685 x 930 x 765

205

2.92

56.00

56.00

1685 x 930 x 765

205

2.92

24.6

8.9

11.8

31.1

11.8

4

40 20 25 50 25 25

R410A

20 HP Single

REYQ20T REYQ10T

20 HP Multi

REYQ10T

data book data book data book data book data book data book

65

86

58

78

58

79

66

88

58

79

58

79

1000

165

1 1/8

5/8

7/8

225 ~ 450

64

3/4

3/8

5/8

100 ~ 260

64

1 1/8

5/8

1 1/8

250 ~ 650

64

1 1/8

5/8

1 1/8

250 ~ 650

64

£10,459.00

£10,459.00

£11,395.00

£10,950.00

58 Residential, Commercial and Industrial

REYQ-T (22 to 28 HP)

VRV IV Condensing Units – Heat Recovery

Outdoor Units

Capacity

Dimensions

Nominal Cooling

Nominal Heating

Height x Width x Depth

Weight

Air Flow Rate

Electrical Details

Refrigerant Circuit

Power Supply

Running Current

Starting Current

Fuse Rating

Refrigerant Type

Refrigerant Charge

Additional Charge

Sound Pressure

Sound Power

Piping Limits

Piping Connections -

Systems

Maximum Total Length

Maximum Actual Length

Gas

Liquid

Discharge

Capacity Index Limit

Maximum Number of Connected Indoor Units

Trade Condensing Unit Price

kW kW mm kg m

3

/sec

Phase amps amps amps kg kg dBA dBA m m inches inches inches

22 HP Multi

REYQ10T REYQ12T

1685 x 930 x 765

61.50

61.50

1685 x 930 x 765

205

2.92

205

3.08

11.8

15.3

25

58

79 data book

1 1/8

5/8

1 1/8

275 ~ 715

64

£12,114.00

25

61

81

24 HP Multi

REYQ8T REYQ16T

26 HP Multi

REYQ12T REYQ14T

1685 x 930 x 765

67.40

67.40

1685 x 1240 x 765

210

2.70

8.9

305

4.33

1685 x 930 x 765

205

3.08

3ph / 50 Hz / 380~415V

21.1

15.3

4

73.50

73.50

1685 x 1240 x 765

319

3.72

17.4

20 40 25 32

R410A data book data book data book

58

78

64

86

61

81

61

81

1000

165

1 3/8

5/8

1 1/8

300 ~ 780

64

1 3/8

3/4

1 1/8

325 ~ 845

64

£14,208.00

£14,466.00

28 HP Multi

REYQ12T REYQ16T

1685 x 930 x 765

78.50

78.50

1685 x 1240 x 765

205

3.08

319

4.33

15.3

21.1

25

61

81 data book

1 3/8

3/4

1 1/8

350 ~ 910

64

£15,863.00

40

64

86

REYQ-T (30 to 36 HP)

VRV IV Condensing Units – Heat Recovery

Outdoor Units

Capacity

Dimensions

Nominal Cooling

Nominal Heating

Height x Width x Depth

Weight

Fan

Electrical Details

Refrigerant Circuit

Air Flow Rate

Power Supply

Running Current

Starting Current

Fuse Rating

Refrigerant Type

Refrigerant Charge

Additional Charge

Sound Pressure

Sound Power

Piping Limits

Piping Connections -

Systems

Maximum Total Length

Maximum Actual Length

Gas

Liquid

Discharge

Capacity Index Limit

Maximum Number of Connected Indoor Units

Trade Condensing Unit Price

kW kW mm kg m

3

/sec

Phase amps amps amps kg kg dBA dBA m m inches inches inches

30 HP Multi

REYQ12T REYQ18T

1685 x 930 x 765

83.50

83.50

1685 x 1240 x 765

205

3.08

329

4.18

15.3

25

61

81 data book

1 3/8

3/4

1 1/8

375 ~ 975

64

24.6

40

65

86

32 HP Multi

REYQ16T REYQ16T

1685 x 1240 x 765

90.00

90.00

1685 x 1240 x 765

319

4.33

21.1

319

4.33

x 765

319

4.33

3ph / 50 Hz / 380~415V

21.1

95.00

95.00

1685 x 1240 1685 x 1240 x 765

329

4.18

24.6

4

34 HP Multi

REYQ16T REYQ18T

40 40 40 40

R410A data book data book data book

64

86

64

86

64

86

65

86

1000

165

1 3/8

3/4

1 1/8

400 ~ 1040

64

1 3/8

3/4

1 1/8

425 ~ 1105

64

36 HP Multi

REYQ16T REYQ20T

101.00

101.00

1685 x 1240 x 765

1685 x 1240 x 765

319

4.33

329

4.35

21.1

40

64

86 data book

1 5/8

3/4

1 1/8

450 ~ 1170

64

31.1

50

66

88

£17,163.00

£18,448.00

£19,748.00

£20,619.00

Price List 2015 59

REYQ-T (38 to 42 HP)

VRV IV Condensing Units – Heat Recovery

Outdoor Units

Capacity

Dimensions

Nominal Cooling

Nominal Heating

Height x Width x Depth

Weight

Fan

Electrical Details

Air Flow Rate

Power Supply

Refrigerant Circuit

Running Current

Starting Current

Fuse Rating

Refrigerant Type

Refrigerant Charge

Additional Charge

Sound Pressure

Sound Power

Piping Limits Maximum Total Length

Maximum Actual Length

Gas Piping Connections -

Systems

Liquid

Discharge

Capacity Index Limit

Maximum Number of Connected Indoor Units

Trade Condensing Unit Price

kW kW mm kg m

3

/sec

Phase amps amps amps kg kg dBA dBA m m inches inches inches

REYQ8T

1685 x 930 x 765

38 HP Multi

REYQ12T

106.40

106.40

1685 x 930 x 765

210

2.70

218

3.08

REYQ18T

1685 x

1240 x

765

337

4.18

8.9

20

58

78

15.3

25 data book data book

61

81

1000

165

1 5/8

3/4

1 3/8

475 ~ 1235

64

£22,147.00

24.6

40

65

86

REYQ10T

40 HP Multi

REYQ12T REYQ18T

1685 x 930 x 765

111.50

111.50

1685 x 930 x 765

1685 x

1240 x

765

205

2.92

205

3.08

3ph / 50 Hz / 380~415V

329

4.18

11.8

24.6

25

58

79

15.3

4

25

R410A data book data book

61

81

1000

165

1 5/8

40

65

86

3/4

1 3/8

500 ~ 1300

64

£22,368.00

REYQ10T

1685 x 930 x 765

205

2.92

42 HP Multi

REYQ16T

118.00

118.00

1685 x

1240 x

765

319

4.33

REYQ16T

1685 x

1240 x

765

319

4.33

11.8

25

58

79

21.1

40 data book data book

64

86

1000

165

1 5/8

3/4

1 3/8

525 ~ 1365

64

£23,923.00

21.1

40

64

86

REYQ-T (44 to 48 HP)

VRV IV Condensing Units – Heat Recovery

Outdoor Units

Capacity

Dimensions

Nominal Cooling

Nominal Heating

Height x Width x Depth

Weight

Fan

Electrical Details

Refrigerant Circuit

Air Flow Rate

Power Supply

Running Current

Starting Current

Fuse Rating

Refrigerant Type

Refrigerant Charge

Additional Charge

Sound Pressure

Sound Power

Piping Limits

Piping Connections -

Systems

Maximum Total Length

Maximum Actual Length

Gas

Liquid

Discharge

Capacity Index Limit

Maximum Number of Connected Indoor Units

Trade Condensing Unit Price

kW kW mm kg m 3 /sec

Phase amps amps amps kg kg dBA dBA m m inches inches inches

REYQ12T

1685 x 930 x 765

205

3.08

44 HP Multi

REYQ16T

123.50

123.50

1685 x

1240 x

765

319

4.33

REYQ16T

1685 x

1240 x

765

319

4.33

15.3

25

21.1

40

21.1

40

61

81 data book data book

64

86

1000

165

1 5/8

3/4

1 3/8

550 ~ 1430

64

£25,087.00

64

86

REYQ14T

1685 x

1240 x

765

319

46 HP Multi

REYQ16T

130.00

130.00

1685 x

1240 x

765

319

REYQ16T

1685 x

1240 x

765

319

3.72

4.33

3ph / 50 Hz / 380~415V

4.33

17.4

21.1

4

21.1

32 40 40

R410A data book data book

61

81

64

86

64

86

1000

165

1 5/8

3/4

1 3/8

575 ~ 1495

64

£26,275.00

REYQ16T

1685 x

1240 x

765

319

4.33

48 HP Multi

REYQ16T

135.00

135.00

1685 x

1240 x

765

319

4.33

REYQ16T

1685 x

1240 x

765

319

4.33

40

21.1

40 40

64

86 data book data book

64

86

1000

165

1 5/8

3/4

1 3/8

600 ~ 1560

64

£27,672.00

64

86

60 Residential, Commercial and Industrial

REYQ-T (50 to 54 HP)

VRV IV Condensing Units – Heat Recovery

Outdoor Units

Capacity

Dimensions

Nominal Cooling

Nominal Heating

Height x Width x Depth

Weight

Fan

Electrical Details

Air Flow Rate

Power Supply

Refrigerant Circuit

Running Current

Starting Current

Fuse Rating

Refrigerant Type

Refrigerant Charge

Additional Charge

Sound Pressure

Sound Power

Piping Limits Maximum Total Length

Maximum Actual Length

Gas Piping Connections -

Systems

Liquid

Discharge

Capacity Index Limit

Maximum Number of Connected Indoor Units

Trade Condensing Unit Price

kW kW mm kg m

3

/sec

Phase amps amps amps kg kg dBA dBA m m inches inches inches

REYQ16T

1685 x

1240 x

765

319

4.33

50 HP Multi

REYQ16T

140.00

140.00

1685 x

1240 x

765

319

4.33

REYQ18T

1685 x

1240 x

765

329

4.18

21.1

40

64

86

21.1

40 data book data book

64

86

1000

165

1 5/8

3/4

1 3/8

625 ~ 1625

64

£28,907.00

24.6

40

65

86

REYQ16T

52 HP Multi

REYQ18T REYQ18T

1685 x

1240 x

765

319

4.33

145.00

145.00

1685 x

1240 x

765

1685 x

1240 x

329

4.18

3ph / 50 Hz / 380~415V

765

329

4.18

21.1

24.6

40

64

86

24.6

4

40

R410A data book data book

65

86

1000

165

1 5/8

40

65

86

3/4

1 3/8

650 ~ 1690

64

£29,732.00

REYQ18T

1685 x

1240 x

765

329

4.18

54 HP Multi

REYQ18T

150.00

150.00

1685 x

1240 x

765

329

4.18

REYQ18T

1685 x

1240 x

765

329

4.18

40

65

86

24.6

40 data book data book

65

86

1000

165

1 5/8

3/4

1 3/8

675 ~ 1755

64

£30,762.00

40

65

86

Price List 2015 61

RYYQ-T

Replaces RXYQ-P9 / RXYHQ-P9 / RXYRQ-P9 / RXHQ-P

Heat Pump VRV IV

3 revolutionary features:

Variable refrigerant temperature

Customise your VRV for best Seasonal Efficiency and comfort:

> Revolutionary variable refrigerant temperature control automatically adapts the system to individual building and climate requirements for greater efficiency and comfort

> Continuously adjusts refrigerant temperature to the actual temperature and capacity required

> Default mode optimised by Daikin for UK conditions with maximum efficiency and comfort

> Delivers annual cost savings of up to 28%

Continuous heating during defrost

The new standard in heating comfort:

> Unique continuous heating technology makes VRV IV Heat Pump the best alternative to traditional heating systems

> Delivers uninterrupted heat, even during the defrost cycle

> Maintains comfortable indoor climate at all times

VRV configurator

Advanced software for simplified commissioning, servicing, configuration and customisation:

> Simplified commissioning: graphical interface to configure, commission and upload system settings

> Simplified servicing: additional 7-segment indicator for easy and quick access to basic functions and error read out

> Manage systems over multiple sites

RYYQ-T (up to 20 HP)

VRV IV Heat Pump with Continuous Heating

Outdoor Units

Capacity Nominal Cooling

Nominal Heating

EER

ESEER

COP

Dimensions Height x Width x Depth

Weight

Air Flow Rate

External Static Pressure High

Electrical Details Power Supply

Refrigerant Circuit

Running Current

Starting Current

Fuse Rating

Refrigerant Type

Refrigerant Charge

Additional Charge

Sound Pressure

Sound Power

Piping Limits Maximum Length

Maximum Vertical Rise

Piping Connections Liquid

Gas

Capacity Index Limit

Maximum Number of Connected Indoor Units

Trade Condensing Unit Price

kW kW kg kg dBA dBA m m inches inches mm kg m

3

/sec

Pa

Phase /Hz / V amps amps amps

7.2

20

5.9

58

78

165

RYYQ8T

22.40

25.00

4.30

7.53*

4.55

1685 x 930 x 765

261

2.70

78

3/8

3/4

100~260

64

£4,542.00

11.3

25

6.0

58

79

165

RYYQ10T

28.00

31.50

3.84

7.2*

4.27

1685 x 930 x 765

268

2.92

78

3/8

7/8

125~325

64

£4,963.00

RYYQ12T

33.50

RYYQ14T

40.00

RYYQ16T

45.00

37.50

3.73

6.96*

4.12

1685 x 930 x 765

268

3.08

78

45.00

3.64

6.83*

4.02

1685 x 1240 x 765

364

3.72

78

3ph / 50 Hz / 380~415V

50.00

3.46

6.5*

3.91

1685 x 1240 x 765

364

4.33

78

12.7

18.0

32

6.3

61

81

165

1/2

1 1/8

150~390

64

15.4

databook

32

R410a

10.3

data book

61

81

165 data book

1/2

1 1/8

175~455

64

40

10.4

64

86

165

1/2

1 1/8

200~520

64

£6,077.00

£7,090.00

£8,183.00

20.8

40

11.7

65

86

165

RYYQ18T

50.00

56.00

3.40

6.38*

3.89

1685 x 1240 x 765

398

4.18

78

5/8

1 1/8

225~585

64

£9,116.00

26.9

50

11.8

66

88

165

RYYQ20T

56.00

63.00

3.03

5.67*

3.71

1685 x 1240 x 765

398

4.35

78

5/8

1 1/8

250~650

64

£10,028.00

* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).

62 Residential, Commercial and Industrial

RYYQ-T (22 to 24 HP)

VRV IV Heat Pump with Continuous Heating

Outdoor Units

Capacity Nominal Cooling

Nominal Heating

EER

ESEER

COP

Dimensions Height x Width x Depth

Weight

Air Flow Rate

External Static Pressure High

Electrical Details

Refrigerant Circuit

Power Supply

Running Current

Starting Current

Fuse Rating

Refrigerant Type

Refrigerant Charge

Additional Charge

Sound Pressure

Sound Power

Piping Limits Maximum Length

Maximum Vertical Rise

Piping Connections Liquid

Gas

Capacity Index Limit

Maximum Number of Connected Indoor Units

Trade Condensing Unit Price

kW kW kg kg dBA dBA m m inches inches mm kg m

3

/sec

Pa

Phase /Hz / V amps amps amps

RYMQ10T

1685 x 930 x 765

195

2.92

78

10.2

25

6.0

58

79

RYYQ22T RYYQ24T

RYMQ12T RYMQ8T

61.50

69.00

3.77

7.07*

4.18

67.40

75.00

3.70

6.81*

4.10

165

5/8

1 1/8

275~715

64

£11,040.00

1685 x 930 x 765

195

3.08

78

1685 x 930 x 765

3ph / 50 Hz / 380~415V

188

2.70

78

12.7

7.2

databook

32 20

R410a

6.3

5.9

databook

61

81

58

78 databook

165

5/8

1 3/8

300~780

64

£12,725.00

RYMQ16T

1685 x 1240 x 765

309

4.33

78

18.0

40

10.4

64

86

* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).

RYYQ-T (26 to 34 HP)

VRV IV Heat Pump with Continuous Heating

Outdoor Units

Capacity Nominal Cooling

Nominal Heating

EER

ESEER

COP

Dimensions Height

Width

Depth

Weight

Air Flow Rate

External Static Pressure High

Electrical Details Power Supply

Refrigerant Circuit

Running Current

Starting Current

Fuse Rating

Refrigerant Type

Refrigerant Charge

Additional Charge

Sound Pressure

Sound Power

Piping Limits

Piping Connections

Maximum Length

Maximum Vertical Rise

Liquid

Gas

Capacity Index Limit

Maximum Number of Connected Indoor Units

Trade Condensing Unit Price

kW kW kg kg dBA dBA m m inches inches mm mm mm kg m

3

/sec

Pa

Phase /Hz / V amps amps amps

RYYQ26T RYYQ28T RYYQ30T RYYQ32T RYYQ34T

RYMQ12T RYMQ14T RYMQ12T RYMQ16T RYMQ12T RYMQ18T RYMQ16T RYMQ16T RYMQ16T RYMQ18T

1685

930

765

195

3.08

78

12.7

32

6.3

61

81

73.50

82.50

3.68

6.89*

4.06

3/4

1 3/8

325~845

64

1685

1240

765

309

3.72

78

15.4

32

10.3

61

81

1685

930

765

195

3.08

78

12.7

32

6.3

61

81

78.50

87.50

3.57

6.69*

4.00

3/4

1 3/8

350~910

64

1685

1240

765

309

4.33

78

18.0

40

10.4

64

86

83.50

93.50

3.52

6.6*

3.98

1685

930

765

195

1685

1240

765

319

3.08

78

4.18

78

3ph / 50 Hz / 380~415V

12.7

databook

20.8

32 40

R410a

6.3

data book

11.7

61

81

165 data book

3/4

65

86

1 3/8

375~975

64

1685

1240

765

309

4.33

78

18.0

40

10.4

64

86

90.00

100.00

3.46

6.5*

3.91

3/4

1685

1240

1 3/8

400~1040

64

765

309

4.33

78

18.0

40

10.4

64

86

1685

1240

765

309

4.33

78

18.0

40

10.4

64

86

95.00

106.00

3.43

6.44*

3.90

3/4

1 3/8

425~1105

64

1685

1240

765

319

4.18

78

20.8

40

11.7

65

86

£13,167.00

£14,260.00

£15,193.00

£16,366.00

£17,299.00

* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).

Price List 2015 63

RYYQ-T (36 to 42 HP)

VRV IV Heat Pump with Continuous Heating

Outdoor Units

Capacity Nominal Cooling

Nominal Heating

EER

ESEER

COP

Dimensions Height

Width

Depth

Weight

Air Flow Rate

External Static Pressure High

Electrical Details Power Supply

Running Current

Refrigerant Circuit

Starting Current

Fuse Rating

Refrigerant Type

Refrigerant Charge

Additional Charge

Sound Pressure

Sound Power

Piping Limits

Piping Connections

Maximum Length

Maximum Vertical Rise

Liquid

Gas

Capacity Index Limit

Maximum Number of Connected Indoor Units

Trade Condensing Unit Price

kW kW kg kg dBA dBA m m inches inches mm mm mm kg m

3

/sec

Pa

Phase /Hz / V amps amps amps

RYYQ36T RYYQ38T RYYQ40T RYYQ42T

RYMQ16T RYMQ20T RYMQ8T RYMQ10T RYMQ20T RYMQ10T RYMQ12T RYMQ18T RYMQ10T RYMQ16T RYMQ16T

1685

1240

765

309

4.33

78

101.00

113.00

3.21

6.02*

3.79

1685

1240

765

319

4.35

78

18.0

64

26.9

40 databook

10.4

64

86

3/4

50

11.8

1 5/8

450~1170

66

88

1685

930

765

188

2.70

78

7.2

20

5.9

58

78

106.00

120.00

3.42

6.36*

4.01

1685

930

765

195

2.92

78

10.2

databook

25

6.0

58

79

3/4

1 5/8

475~1235

64

1685

1240

765

319

4.35

78

50

11.8

66

88

1685

930

765

195

2.92

78

25

R410a

6.0

data book

58

79

165 data book

112.00

125.00

3.61

6.74*

4.05

1685

930

765

195

3.08

78

3ph / 50 Hz / 380~415V

26.9

10.2

12.7

databook

32

6.3

61

81

3/4

1 5/8

500~1300

64

1685

1240

765

319

4.18

78

20.8

40

11.7

65

86

1685

930

765

195

2.92

78

10.2

25

6.0

58

79

118.00

132.00

3.54

6.65*

4.00

1685

1240

765

309

4.33

78

18.0

databook

40

10.4

64

86

3/4

1 5/8

525~1365

64

1685

1240

765

309

4.33

78

18.0

40

10.4

64

86

£18,211.00

£19,533.00

£20,156.00

£21,329.00

* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).

RYYQ-T (44 to 48 HP)

VRV IV Heat Pump with Continuous Heating

Outdoor Units

Capacity Nominal Cooling

Nominal Heating

EER

ESEER

COP

Dimensions Height

Width

Depth

Weight

Air Flow Rate

External Static Pressure High

Electrical Details Power Supply

Running Current

Starting Current

Refrigerant Circuit

Fuse Rating

Refrigerant Type

Refrigerant Charge

Additional Charge

Sound Pressure

Sound Power

Piping Limits Maximum Length

Piping Connections

Maximum Vertical Rise

Liquid

Gas

Capacity Index Limit

Maximum Number of Connected Indoor Units

Trade Condensing Unit Price

kW kW kg kg dBA dBA m m inches inches mm mm mm kg m

3

/sec

Pa

Phase /Hz / V amps amps amps

RYYQ44T RYYQ46T RYYQ48T

RYMQ12T RYMQ16T RYMQ16T RYMQ14T RYMQ16T RYMQ16T RYMQ16T RYMQ16T RYMQ16T

1685

930

765

195

3.08

78

12.7

32

6.3

61

81

124.00

138.00

3.54

6.62*

3.98

1685

1240

765

309

4.33

78

18.0

databook

40

10.4

64

86

1685

1240

765

309

4.33

78

18.0

40

10.4

64

86

1685

1240

765

309

3.72

130.00

145.00

3.51

6.6*

3.94

1685

1240

765

309

4.33

1685

1240

765

309

4.33

78

15.4

78

3ph / 50 Hz / 380~415V

18.0

databook

78

18.0

32 40

10.3

40

R410a

10.4

data book

10.4

61

81

64

86

165

64

86

1685

1240

765

309

4.33

78

18.0

40

10.4

64

86

135.00

150.00

3.46

6.5*

3.91

1685

1240

765

309

4.33

78

18.0

databook

40

10.4

64

86

1685

1240

765

309

4.33

78

18.0

40

10.4

64

86

3/4

1 5/8

550~1430

64 data book

3/4

1 5/8

575~1495

64

3/4

1 5/8

600~1560

64

£22,443.00

£23,456.00

£24,549.00

* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).

64 Residential, Commercial and Industrial

RYYQ-T (50 to 54 HP)

VRV IV Heat Pump with Continuous Heating

Outdoor Units

Capacity Nominal Cooling

Nominal Heating

EER

ESEER

COP

Dimensions Height

Width

Depth

Weight

Air Flow Rate

External Static Pressure High

Electrical Details Power Supply

Running Current

Starting Current

Refrigerant Circuit

Fuse Rating

Refrigerant Type

Refrigerant Charge

Additional Charge

Sound Pressure

Sound Power

Piping Limits

Piping Connections

Maximum Length

Maximum Vertical Rise

Liquid

Gas

Capacity Index Limit

Maximum Number of Connected Indoor Units

Trade Condensing Unit Price

kW kW kg kg dBA dBA m m inches inches mm mm mm kg m

3 /sec

Pa

Phase amps amps amps

RYYQ50T RYYQ52T RYYQ54T

RYMQ16T RYMQ16T RYMQ18T RYMQ16T RYMQ18T RYMQ18T RYMQ18T RYMQ18T RYMQ18T

1685

1240

765

309

4.33

78

18.0

40

10.4

64

86

140.00

156.00

3.44

6.46*

3.90

1685

1240

765

309

4.33

78

18.0

databook

40

10.4

64

86

1685

1240

765

319

4.18

78

20.8

40

11.7

65

86

1685

1240

765

309

145.00

162.00

3.42

6.42*

3.89

1685

1240

765

319

1685

1240

765

319

4.33

78

18.0

4.18

78

4.18

78

3ph / 50 Hz / 380~415V

20.8

20.8

40

10.4

databook

40

R410a

11.7

40

11.7

64

86 data book

65

86

65

86

1685

1240

765

319

4.18

78

20.8

40

11.7

65

86

150.00

168.00

3.40

6.38*

3.89

1685

1240

765

319

4.18

78

20.8

databook

40

11.7

65

86

1685

1240

765

319

4.18

78

20.8

40

11.7

65

86

3/4

1 5/8

625~1625

64

165 data book

3/4

1 5/8

650~1690

64

3/4

1 5/8

675~1755

64

£25,482.00

£26,415.00

£27,348.00

* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).

Price List 2015 65

Unseen in all the best places

66

Keep a low profile

We’re keeping a low profile with our new VRV IV S-series.

Standing less than 1m from the ground including feet, our new compact VRV

IV S-series is the lowest profile VRV unit in the market today. So it’s perfect for all kinds of tight spots and urban spaces. Available in 4 & 5 HP single phase, this lightweight single-fan unit joins our newly extended range of double-fan

VRV IV S-series available in either single or 3-phase. All have front-blow, so can be located on a balcony or enclosed area. Plus every unit in the range now features VRV IV technology with variable refrigerant temperature control. So now you can get all the power of a VRV, in the smallest of spaces.

Find out more at www.daikin.co.uk

16/02/2015 14:28:22

NEW

AVAILABLE

MID 2015

RXYSCQ

Low Height Mini VRV

Outdoor Units

Capacity

Dimensions

Weight

Refrigerant Circuit

Sound Pressure

Sound Power

Piping Limits

Piping Connections

Capacity Index Limit

Trade Condensing Unit Price

Nominal Cooling

Nominal Heating

Height x Width x Depth

Refrigerant Type

(Cooling)

(Cooling)

Maximum Length

Maximum Vertical Rise

Liquid

Gas kW kW mm kg dBA dBA m m inches inches

RXYSCQ4

12.1

12.1

823 x 940 x 460

88

51

68

3/8

5/8

50~130

£2,462.00

Features:

> New low height Mini VRV, making complying with planning restrictions in towns and cities easier

> Compact – Only 823mm high

> Lightweight – for simple installation

> Variable Refrigerant temperature – Enhanced efficiency

> In addition to VRV fan coils, low height Mini VRV is connectable to:

Stylish indoor units – Emura and Nexura

Air Handling Units

Biddle Air Curtains

> Single phase

R410a

70

30

RXYSCQ5

14

14

823 x 940 x 460

88

52

69

3/8

5/8

62.5~162.5

£2,767.00

Roof

Planning issues for small commercial or residential projects in towns and cities can now be easy to overcome with a Low height version of the mini VRV range, available in 4 & 5HP with Variable Refrigerant

Temperature and connection to products such as Air Curtains, Air handling units and the Emura and

Nexura fan coils, the Low height Mini VRV range brings a whole new level of versatility to the VRV range.

Price List 2015 67

RXYSQ

VRV III Condensing Units – Heat Pump Inverter Mini

Updated VRV IV version

including Variable Refrigerant Temperature control

available during autumn 2015.

Outdoor Units

Capacity

Dimensions

Weight

Air Flow Rate

Electrical Details

Nominal Cooling

Nominal Heating

Height x Width x Depth

Power Supply

Refrigerant Circuit

Running Current

Starting Current

Fuse Rating

Refrigerant Type

Refrigerant Charge

Additional Charge

Sound Pressure

Sound Power

Piping Limits

Piping Connections

Maximum Length

Maximum Vertical Rise

Liquid

Gas

Capacity Index Limit

Maximum Number of Connected Indoor Units

Trade Condensing Unit Price

kW kW mm kg m 3 /sec

Phase

Hz

V amps amps amps kg kg dBA dBA m m inches inches

Notes:

The VRV III-S is highly space saving, featuring a slimmer and more compact outdoor unit compared to conventional models. Supplied in three sizes of 4 HP (11.2 kW), 5HP (14 kW) and 6HP (15.5 kW) with a single or three phase power supply. Compatible with the full range

of existing VRV fan coil units providing a choice of 12 types and 72 models. Installation is improved by the completely new casing design of the outdoor unit with a footprint of just

320mm deep by 900mm wide, which reduces installation space requirements by over 40%

(14.0kW model) and enables it to fit easily onto balconies and narrow ledges. Maximum piping length is 150m, total piping length is 300m and maximum vertical differential between outdoor and indoor units is 50m (40m when outdoor is below indoor units). The Daikin ‘Super Wiring’ system allows shared use of the wiring between indoor and outdoor units and the centralised remote control, the non polarity of the system obviating incorrect connection and reducing installation time.

RXYSQ4P8V1

12.60

14.20

1345 x 900 x 320

120

1.77

15.9

4

32

RXYSQ5P8V1

14.00

16.00

1345 x 900 x 320

120

1.77

1ph

50

230

20.2

4

32

RXYSQ6P8V1

15.50

18.00

1345 x 900 x 320

120

1.77

RXYSQ4P8Y1

12.60

14.20

1345 x 900 x 320

120

1.77

50

66

3/8

5/8

50~130

8

£2,735.00

51

67

3/8

5/8

62.5~162.5

10

£3,074.00

22.2

4

32

53

69

3/8

3/4

70~182

12

5.3

4

16

R410a

4.0

data book

50

66

300 data book

3/8

5/8

50~130

8

£3,431.00

£2,788.00

RXYSQ5P8Y1

14.00

16.00

1345 x 900 x 320

120

1.77

3ph

50

400

6.8

4

16

RXYSQ6P8Y1

15.50

18.00

1345 x 900 x 320

120

1.77

7.8

4

16

51

67

3/8

5/8

62.5~162.5

10

£3,160.00

53

69

3/8

3/4

70~182

12

£3,510.00

3

Advanced technologies

1

Super aero grille

The spiral shaped ribs are aligned with the direction of discharge flow in order to minimise turbulence and reduce noise.

2

Smooth air inlet bell mouth and aero spiral fan

These features assist in significantly reducing noise. Guides are added to the bell mouth intake to reduce turbulence in the air flow generated by fan suction. The aero spiral fan features fan blades with bent blade edges, further reducing turbulence.

2

1

68

3

e-Bridge circuit

Prevents accumulation of liquid refrigerant in the condenser.

This results in more efficient use of the condenser surface under all conditions and leads in turn to better energy efficiency.

Increased evaporative capacity stems from the newly developed refrigeration circuit, the SCe-bridge circuit, which adds super cooling prior to the expansion cycle. By adopting this circuit, the

COPs in both cooling and heating have been drastically improved.

Aero spiral fan blade tips

Conventional New

Escaping edges are sucked in by the bent blade edges, reducing overall turbulence.

Residential, Commercial and Industrial

RXYQQ-T / RQEQ-P3

Replacement VRV-Q

Optimise your business

Tackle more projects in less time:

Due to faster installation. VRV-Q is more profitable than replacing the full system with new piping.

Lower installation costs:

Offer customers the most cost-effective solution and improve your competitive edge.

Easy as one-two-three:

A simple solution: Daikin VRV-Q enables you to handle more projects for more customers in less time and offer them the best price! Everybody wins.

New

Now it's possible to connect VRV IV BS boxes, including the small, light Multi BS boxes designed to offer the largest & most flexible range of design & installation options available.*

* VRV IV single and multi BS Box connectivity coming spring 2015, please speak to your local Daikin representative to ensure your system design is available for delivery when your project starts.

Compare installation steps

Conventional solution VRV-Q

1 Recover refrigerant 1 Recover refrigerant

2 Remove units 2 Remove units

3 Remove refrigerant pipes

4 Install new piping/wiring

5 Install new units

6 Leak test

7 Vacuum drying

8 Refrigerant charging

9 Collect contamination

10 Test operation

Re-use existing piping and wiring

3 Install new units

4 Leak test

5 Vacuum drying

6 Automatic refrigerant charging, cleaning and testing

Up to 45% shorter

installation time

Customer benefits

Always operational

Avoid loss of business

Replacing now prevents unplanned, lengthy disruption of air conditioning systems. It also avoids loss of business for shops, complaints from guests in hotels, lower working efficiency and loss of tenants in offices.

Quick and easy installation

No interruption of daily business while replacing the system thanks to phased-in, fast installation.

Lower long-term costs

EU Directives prohibit system repairs with R-22 after 31 December 2014.

Replacement day has arrived. Installing a technically advanced system lowers energy consumption and maintenance costs from day one.

The Daikin low-cost upgrade solution

4

Reuse drain pipes

Durable PVC pipes can be easily reused. Only flow tests are required.

4

Reuse refrigerant pipes

Pipes used for R-22 will also work with VRV-Q, thanks to lower operating pressures of the system.

4

Reuse refrigerant branch pipes

There are no restrictions when upgrading from a Daikin VRV system.

Other VRF systems require branch pipes to withstand pressure up to 3.3 MPa.

!

Replace indoor units and BS boxes

Contact your local dealer to check compatibility in case you need to keep the indoor units.

4

Reuse remote control wiring

Reuse wiring when upgrading from a Daikin VRV system. In other cases, this will depend on the cable type.

4

Reuse indoor-outdoor wiring

Restrictions: see remote control wiring.

!

Replace outdoor units

Reduced energy consumption

R-22 (RSXY-KA7) R-407C (RSXYP-L7) R-410A (RXYQQ-T)

Comparison of

10HP systems:

Cooling mode

Heating mode

Price List 2015 69

RXYQQ-T (up to 20 HP)

VRV IV-Q Condensing Unit – Heat Pump

Outdoor Units

Capacity Nominal Cooling

Nominal Heating

EER

ESEER

COP

Dimensions Height

Width

Depth

Weight

Air Flow Rate

External Static Pressure High

Electrical Details Power Supply

Refrigerant Circuit

Running Current

Starting Current

Fuse Rating

Refrigerant Type

Refrigerant Charge

Additional Charge

Sound Pressure

Sound Power

Piping Limits

Piping Connections

Maximum Length

Maximum Vertical Rise

Liquid

Gas

Capacity Index Limit

Maximum Number of Connected Indoor Units kW kW kg kg dBA dBA m m inches inches mm mm mm kg m

3

/sec

Pa

Phase /Hz / V amps amps amps

7.2

20

5.2

58

78

120

3/8

3/4

100~260

64

RXYQQ8T

22.40

25.00

4.30

7.53*

4.54

1685

930

765

187

2.10

78

10.2

25

6.0

58

79

120

3/8

7/8

125~325

64

RXYQQ10T

28.00

31.50

3.84

7.2*

4.27

1685

930

765

194

2.92

78

12.7

32

6.3

61

81

120

1/2

1 1/8

150~390

64

RXYQQ12T

33.50

37.50

3.73

6.96*

4.12

1685

930

765

194

3.08

78

15.4

4

32

R410a

10.3

data book

61

81

120

50

1/2

1 1/8

175~455

64

RXYQQ14T

40.00

45.00

3.64

6.83*

4.02

1685

1240

765

306

3.72

78

3ph / 50 / 400

18.0

40

10.4

64

86

120

1/2

1 1/8

200~520

64

RXYQQ16T

45.00

50.00

3.46

6.5*

3.91

1685

1240

765

305

3.88

78

20.8

40

11.7

65

86

120

5/8

1 1/8

225~585

64

RXYQQ18T

50.00

56.00

3.40

6.38*

3.89

1685

1240

765

314

4.18

78

RXYQQ20T

56.00

63.00

3.03

5.67*

3.71

1685

1240

765

314

4.35

78

Trade Condensing Unit Price £5,077.00

£5,548.00

£6,435.00

£7,508.00

£8,665.00

£10,165.00

£11,161.00

*The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrifgerant temperature control operation).

Please contact your local sales office

regarding VRV IV-Q warranty and installation.

26.9

50

11.8

66

88

120

5/8

1 1/8

250~650

64

RXYQQ-T (22 to 28 HP)

VRV IV-Q Condensing Unit – Heat Pump

Outdoor Units

Capacity Nominal Cooling

Nominal Heating

EER

ESEER

COP

Dimensions Height

Width

Depth

Weight

Air Flow Rate

External Static Pressure High

Electrical Details Power Supply

Running Current

Starting Current

Refrigerant Circuit

Fuse Rating

Refrigerant Type

Refrigerant Charge

Additional Charge

Sound Pressure

Sound Power

Piping Limits

Piping Connections

Maximum Length

Maximum Vertical Rise

Liquid

Gas

Capacity Index Limit

Maximum Number of Connected Indoor Units kW kW kg kg dBA dBA m m inches inches mm mm mm kg m

3

/sec

Pa

Phase /Hz / V amps amps amps

RXYQQ22T

RXYQQ10T

61.50

RXYQQ12T

69.00

3.77

7.07*

4.18

1685

930

765

194

2.92

1685

930

765

194

3.08

78

25

6.0

58

79

22.9

5/8

1 1/8

275~715

64

32

6.3

61

81

RXYQQ24T

RXYQQ8T

67.40

RXYQQ16T

75.00

3.70

6.81*

4.10

1685

930

765

187

2.10

1685

1240

765

305

3.88

78

RXYQQ26T

RXYQQ12T

1685

3ph / 50 / 400

930

765

194

3.08

73.50

82.50

3.68

6.89*

4.06

78

RXYQQ14T

1685

1240

765

306

3.72

25.2

28.1

88

20 40 32 32

R410a

5.2

10.4

6.3

10.3

data book

58

78

64

86

61

81

61

81

120

50

5/8

1 3/8

300~780

64

3/4

1 3/8

325~845

64

RXYQQ28T

RXYQQ12T

78.50

RXYQQ16T

87.50

3.57

6.69*

4.00

1685

930

765

194

3.08

1685

1240

765

305

3.88

78

32

6.3

61

81

30.7

3/4

1 3/8

350~910

64

40

10.4

64

86

Trade Condensing Unit Price £11,983.00

£13,742.00

£13,943.00

£15,100.00

*The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrifgerant temperature control operation).

Please contact your local sales office

regarding VRV IV-Q warranty and installation.

70 Residential, Commercial and Industrial

RXYQQ-T (30 to 36 HP)

VRV IV-Q Condensing Unit – Heat Pump

Outdoor Units

Capacity Nominal Cooling

Nominal Heating

EER

ESEER

COP

Dimensions Height

Width

Depth

Weight

Air Flow Rate

External Static Pressure High

Electrical Details Power Supply

Running Current

Starting Current

Refrigerant Circuit

Fuse Rating

Refrigerant Type

Refrigerant Charge

Additional Charge

Sound Pressure

Sound Power

Piping Limits

Piping Connections

Maximum Length

Maximum Vertical Rise

Liquid

Gas

Capacity Index Limit

Maximum Number of Connected Indoor Units kW kW kg kg dBA dBA m m inches inches mm mm mm kg m

3 /sec

Pa

Phase /Hz / V amps amps amps

RXYQQ30T

RXYQQ12T RXYQQ18T

83.50

93.50

3.52

6.6*

3.98

1685

930

765

194

1685

1240

765

314

3.08

4.18

78

33.5

32

6.3

61

81

40

11.7

65

86

3/4

1 3/8

375~975

64

RXYQQ32T

RXYQQ16T RXYQQ16T

90.00

100.00

3.46

6.5*

3.91

1685

1240

765

305

1685

1240

765

305

3.88

3.88

78

3.88

3ph / 50 / 400

RXYQQ34T

RXYQQ16T RXYQQ18T

95.00

106.00

3.43

6.44*

3.90

1685

1240

765

305

1685

1240

765

314

78

4.18

36.0

38.8

108

40 40 40 40

R410a

10.4

10.4

10.4

11.7

data book

64

86

64

86

64

86

65

86

120

50

3/4

1 3/8

400~1040

64

3/4

1 3/8

425~1105

64

RXYQQ36T

RXYQQ16T RXYQQ20T

101.00

113.00

3.21

6.02*

3.79

1685

1240

765

305

1685

1240

765

314

3.88

4.35

78

44.9

40

10.4

64

86

50

11.8

66

88

3/4

1 5/8

450~1170

64

Trade Condensing Unit Price £16,600.00

£17,330.00

£18,830.00

£19,826.00

*The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrifgerant temperature control operation).

Please contact your local sales office

regarding VRV IV-Q warranty and installation.

RXYQQ-T (38 to 42 HP)

VRV IV-Q Condensing Unit – Heat Pump

Outdoor Units

Capacity Nominal Cooling

Nominal Heating

EER

ESEER

COP

Dimensions Height

Width

Depth

Weight

Air Flow Rate

External Static Pressure High

Electrical Details Power Supply

Running Current

Starting Current

Refrigerant Circuit

Fuse Rating

Refrigerant Type

Refrigerant Charge

Additional Charge

Sound Pressure

Sound Power

Piping Limits

Piping Connections

Maximum Length

Maximum Vertical Rise

Liquid

Gas

Capacity Index Limit

Maximum Number of Connected Indoor Units kW kW kg kg dBA dBA m m inches inches mm mm mm kg m

3

/sec

Pa

Phase /Hz / V amps amps amps

RXYQQ38T RXYQQ40T RXYQQ42T

RXYQQ8T RXYQQ10T RXYQQ20T RXYQQ10T RXYQQ12T RXYQQ18T RXYQQ10T RXYQQ16T RXYQQ16T

106.00

112.00

118.00

120.00

3.42

125.00

3.61

132.00

3.54

1685

930

765

187

2.10

78

20

6.36*

4.01

1685

930

765

194

2.92

78

44.3

111

25

1685

1240

765

314

4.35

78

50

1685

930

765

194

2.92

78

25

6.74*

4.05

1685

930

765

194

3.08

78

3ph / 50 / 400

43.7

111

1685

1240

765

314

4.18

78

40

1685

930

765

194

2.92

78

25

6.65*

4.00

1685

1240

765

305

3.88

78

46.2

122

40

1685

1240

765

305

3.88

78

40

5.2

58

78

6.0

58

79

3/4

1 5/8

475~1235

64

11.8

66

88

6.0

58

79

32

R410a

6.3

data book

61

81

120

50

3/4

1 5/8

500~1300

64

11.7

65

86

6.0

58

79

10.4

64

86

3/4

1 5/8

525~1365

64

10.4

64

86

Trade Condensing Unit Price £21,786.00

£22,148.00

£22,878.00

*The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrifgerant temperature control operation).

Please contact your local sales office

regarding VRV IV-Q warranty and installation.

Price List 2015 71

RQCEQ-P3 (28.0 to 45.0 kW)

VRV III-Q Condensing Unit – Heat Recovery

Outdoor Units

Capacity

Dimensions

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Air Flow Rate

External Static Pressure High

Electrical Details Power Supply

Refrigerant Circuit

Running Current

Starting Current

Fuse Rating

Refrigerant Type

Refrigerant Charge

Additional Charge

Sound Pressure

Piping Limits Maximum Length

Maximum Vertical Rise

Piping Connections Liquid

Gas

Capacity Index Limit

Maximum Number of Connected Indoor Units kW kW mm mm mm kg m

3

/sec

Pa

Phase

Hz

V amps amps amps kg kg dBA m m inches inches

RQCEQ280P3

RQEQ140P3 RQEQ140P3

28.00

32.00

1680

635

765

175

1.58

1680

635

765

175

1.58

78

15

10.3

54

5.5+5.5

4

120

15

10.3

54

3/8

7/8

125~325

16

RQCEQ360P3

RQEQ180P3 RQEQ180P3

36.00

40.00

1680

635

765

175

1.58

1680

635

765

175

1.58

78

3ph

50

400

8.0+8.0

4

20

10.6

58

20

R410a

10.6

data book

58

120

50

1/2

1

162.5~422.5

20

RQEQ140P3

15

10.3

54

1680

635

765

175

1.58

RQCEQ460P3

RQEQ140P3

45.00

52.00

1680

635

765

175

1.58

78

5.5+5.5+8.0

4

15

10.3

54

120

1/2

1 1/8

200~520

26

RQEQ180P3

20

10.6

58

1680

635

765

175

1.58

Trade Condensing Unit Price £6,570.00

£8,450.00

£10,795.00

Please see note on page 74

regarding VRV III-Q warranty, and contact your local sales office for more information on VRV III-Q installation.

RQCEQ-P3 (50.0 to 63.6 kW)

VRV III-Q Condensing Unit – Heat Recovery

Outdoor Units

Capacity

Dimensions

Weight

Air Flow Rate

Electrical Details

Nominal Cooling

Nominal Heating

Height

Width

Depth

Power Supply

Refrigerant Circuit

Running Current

Starting Current

Fuse Rating

Refrigerant Type

Refrigerant Charge

Additional Charge

Sound Pressure

Piping Limits

Piping Connections

Maximum Length

Maximum Vertical Rise

Liquid

Gas

Discharge

Oil Equalising

Capacity Index Limit

Maximum Number of Connected Indoor Units kW kW mm mm mm kg m

3

/sec

Phase

Hz

V amps amps amps kg kg dBA m m inches inches inches inches

RQCEQ500P3 RQCEQ540P3 RQCEQ636P3

RQEQ140P3 RQEQ180P3 RQEQ180P3 RQEQ180P3 RQEQ180P3 RQEQ180P3 RQEQ212P3 RQEQ212P3 RQEQ212P3

1680

635

765

175

1.58

15

10

54

50.00

56.00

1680

635

765

175

1.58

5.5+8.0+8.0

4

20

11

58

5/8

1 1/8

7/8

-

225~585

29

1680

635

765

175

1.58

20

11

58

1680

635

765

175

1.58

20

11

58

54.00

60.00

R410a

11 data book

58

120

50

5/8

1 1/8

7/8

-

250~650

33

1680

635

765

175

1.58

3ph

50

400

8.0+8.0+8.0

4

20

1680

635

765

175

1.58

20

11

58

1680

635

765

179

1.83

20

11

60

63.60

67.20

1680

635

765

179

1.83

11.5+11.5+11.5

4

20

11

60

5/8

1 1/8

1

-

275~715

36

1680

635

765

179

1.83

20

11

60

Trade Condensing Unit Price £11,735.00

£12,675.00

£14,937.00

Please see note on page 74

regarding VRV III-Q warranty, and contact your local sales office for more information on VRV III-Q installation.

72 Residential, Commercial and Industrial

RQCEQ-P3 (71.2 to 74.4 kW)

VRV III-Q Condensing Unit – Heat Recovery

Outdoor Units

Capacity

Dimensions

Weight

Air Flow Rate

Electrical Details

Nominal Cooling

Nominal Heating

Height

Width

Depth

Power Supply

Refrigerant Circuit

Running Current

Starting Current

Fuse Rating

Refrigerant Type

Refrigerant Charge

Additional Charge

Sound Pressure

Piping Limits

Piping Connections

Maximum Length

Maximum Vertical Rise

Liquid

Gas

Discharge

Oil Equalising

Capacity Index Limit

Maximum Number of Connected Indoor Units

Trade Condensing Unit Price

kg kg dBA m m inches inches inches inches kW kW mm mm mm kg m

3

/sec

Phase

Hz

V amps amps amps

RQCEQ712P3 RQCEQ744P3

RQEQ140P3 RQEQ180P3 RQEQ180P3 RQEQ212P3 RQEQ140P3 RQEQ180P3 RQEQ212P3 RQEQ212P3

71.20

78.40

74.40

80.80

1680

635

765

175

1.58

1680

635

765

175

1.58

1680

635

765

175

1.58

1680

635

765

179

1.83

1680

635

765

175

1.58

1680

635

765

175

1.58

1680

635

765

179

1.83

1680

635

765

179

1.83

3ph

50

400

15

5.5+8.0+8.0+11.5

4

20 20 20 15

5.5+8.0+11.5+11.5

4

20 20 20

R410a

10.3

10.6

10.6

11.2

10.3

10.6

11.2

11.2

data book

54 58 58 60 54 58 60 60

120

50

5/8

1 1/8

1

-

300~780

40

3/4

1 3/8

1

-

325~845

43

£16,714.00

£17,468.00

Please see note on page 74

regarding VRV III-Q warranty, and contact your local sales office for more information on VRV III-Q installation.

RQCEQ-P3 (81.6 to 84.8 kW)

VRV III-Q Condensing Unit – Heat Recovery

Outdoor Units

Capacity

Dimensions

Weight

Air Flow Rate

Electrical Details

Nominal Cooling

Nominal Heating

Height

Width

Depth

Power Supply

Refrigerant Circuit

Running Current

Starting Current

Fuse Rating

Refrigerant Type

Refrigerant Charge

Additional Charge

Sound Pressure

Piping Limits

Piping Connections

Maximum Length

Maximum Vertical Rise

Liquid

Gas

Discharge

Oil Equalising

Capacity Index Limit

Maximum Number of Connected Indoor Units kg kg dBA m m inches inches inches inches kW kW mm mm mm kg m

3

/sec

Phase

Hz

V amps amps amps

RQCEQ816P3 RQCEQ848P3

RQEQ180P3 RQEQ212P3 RQEQ212P3 RQEQ212P3 RQEQ212P3 RQEQ212P3 RQEQ212P3 RQEQ212P3

81.60

87.20

84.80

89.60

1680

635

765

175

1.58

1680

635

765

179

1.83

1680

635

765

179

1.83

1680

635

765

179

1.83

1680

635

765

179

1.83

1680

635

765

179

1.83

1680

635

765

179

1.83

1680

635

765

179

1.83

3ph

50

400

20

8.0+11.5+11.5+11.5

4

20 20 20 20

11.5+11.5+11.5+11.5

4

20 20 20

R410a

10.6

11.2

11.2

11.2

11.2

11.2

11.2

11.2

data book

58 60 60 60 60 60 60 60

120

50

3/4

1 3/8

1 1/8

-

350~910

47

3/4

1 3/8

1 1/8

-

375~975

50

Trade Condensing Unit Price £19,162.00

£19,916.00

Please see note on page 74

regarding VRV III-Q warranty, and contact your local sales office for more information on VRV III-Q installation.

Price List 2015 73

NEW

SIMPLIFIED

PROCESS

VRV-Q Warranty

Warranty and Site Services

The warranty for VRV-Q systems operates under different conditions to our standard warranty. To ensure complete suitability of the existing site, a choice of optional warranty and special site services packages are available from Daikin Airconditioning UK Ltd. These choices will ensure the VRV-Q system is designed and commissioned to provide the client with complete ‘peace of mind’ operation.

The choices include:

a) Pre-order checks on the existing pipework and fan coils installed on the clients’ site to ensure suitability for VRV-Q installation b) Commissioning of the new VRV-Q installation to ensure correct and efficient operation

Warranty options for 3 or 5 years are available depending on the qualification criteria and the type of system being installed.

Commissioning Log Books should be available for inspection by

Daikin Airconditioning UK Ltd if required.

The tables below provide an overview of the choices, with a brief description on page 75. For full details please contact your local sales office.

VRV-Q Warranty Choices

1. VRV-Q combined with new fan coil units

Warranty Package Level

Condensing Unit Warranty Period

Fan Coil Unit Warranty Period

Site Pre-Order Inspection

Commissioning

For Site with New Fan Coils non D1/D1+

3 Years

D1/D1+

5 Years

3 Years 5 Years

By trained approved engineer

(1)

OR by Daikin Airconditioning UK Ltd (additional cost)

By approved engineer (1) (subsequent projects) OR by Daikin Airconditioning UK Ltd (additional cost)

2. VRV-Q combined with existing fan coil units

Warranty Package Level

Condensing Unit Warranty Period

Existing Fan Coil Unit Warranty Period

Site Pre-Order Inspection

Commissioning

For Site with Existing Fan Coils non D1/D1+ D1/D1+

3 Years

0 Years

5 Years

0 Years

By trained approved engineer (1) (2) OR by Daikin Airconditioning UK Ltd (additional cost)

By approved engineer (1) (subsequent projects) OR by Daikin Airconditioning UK Ltd (additional cost)

Notes:

(1)

Approved engineer to sign commissioning report and be able to identify DAUK official training programme attended, SE19 VRV-Q required

(2)

Trained approved engineer to collect 2 hours of data per system from the service checker for assessment

Daikin Support Options

Site pre-order inspection per system*

Site pre-inspection (existing fan coils) including 2 hour service checker analysis per system*

Daikin commissioning per system*

Daikin full day commissioning assistance

Cost

£175.00

£285.00

£400.00

£585.00

Code

UK.SFV/N/INSP

UK.SFV/E/INSP

UK.SFV/SYCOMM

UK.SFV/FULLCOMM

*System is defined as a maximum of 3 connected condensers. All prices shown are Net. No further discount can be applied.

74 Residential, Commercial and Industrial

VRV-Q Warranty Detail

Approved engineer

An approved engineer is an engineer who:

1. Is suitably registered in accordance with F-gas regulations;

2. Has successfully completed a Daikin Airconditioning UK Ltd VRV Air Cooled installation and commissioning course within the last 3 years.

3. Has completed SE19 VRV-Q course in the past 3 years.

Net price

Net price, exclusive of VAT and subject to our standard terms and conditions.

No other discounts are applicable.

Prices shown for site pre-order inspection and commissioning are for work undertaken during normal working hours between 09:00 and 17:30. Any request for attendance to site out of these hours is subject to additional charges.

Warranty

To activate the warranty the Daikin Airconditioning UK Ltd VRV Commissioning

Log Book will need to be fully completed and submitted to Daikin Airconditioning

UK Ltd FQS department for checking. Upon receipt and validation that all required details are provided and satisfactory, Daikin Airconditioning UK Ltd will issue a confirmation letter that the warranty is activated. Where Daikin Airconditioning UK

Ltd will complete the commissioning we will provide a copy of the Commissioning

Log Book to the installation contractor. Except where mentioned above, our standard warranty conditions will apply. If none of the packaged options are chosen, then the warranty will be limited to a standard 12 month parts only cover.

Site pre-order inspection

Where required, Daikin Airconditioning UK Ltd will attend the site to check the suitability of the existing equipment and pipework for connection to VRV-Q. Where it is not possible to check operation or equipment condition, this will also be highlighted in the final report, and appropriate recommendations made.

If an approved engineer carries out the site inspection, then a Daikin

Airconditioning UK Ltd supplied form shall be completed and submitted to our

FQS department for checking and approval prior to any order being accepted.

The pre-order site inspection will include for the following items.

• Existing system(s) capacity – necessary to estimate required system load for the new system

• Record all the model numbers and the serial numbers for the indoor and the outdoor units and indicate actual installed system combinations

• Check status of the existing indoor units – necessary if the existing units are to be reused

• Check filter condition

• Check coil condition

• Check fan motor operation – select fan only and check for air movement and for unusual noise and vibration

• Installed pipework details – necessary to check compliance with the manufacturer’s specification and assess install quality. This would highlight any required rectification prior to the installation of the new system

• Provide as installed pipework diagrams. If not available, provide as installed pipe work schematics from information gathered on site

• Check the distance from the outdoor to the farthest indoor along the pipe work route

• Check the distance from the first Refnet fitting to the farthest indoor unit

• Check the height difference between the outdoor and the lowest indoor when the outdoor is situated above the indoor units or height difference between the outdoor and the highest indoor if the outdoor is situated below the indoor units

• Check the height difference between the highest and the lowest indoor connected to the same system

• Provide the lengths of all installed pipe sizes

• Check the installation position and angle of the Refnet Joints

• Check the condition of the pipe insulation

• Check the adequacy of the existing pipe supports

• Installed communication and control wiring – necessary to check compliance with the manufacturer’s specification, suitability for the new system and suitability for new controls specification

• Check sizes and type of the interconnecting communication cables between indoor units, outdoor units and any central control systems

• Check the separation between the power wiring and the installed controls wiring

• Power wiring to the outdoor units – necessary to check suitability for the new outdoor units

• Check supply voltage

• Check number of outlets available adjacent to the outdoor units compound

• Check fuse/MCB sizes and types

• Check status of the isolators

Price List 2015 75

VRV-Q Warranty Detail

operating to their optimum. If there are issues which may affect the new installation they need to identified and rectified before installation of the new system. A comprehensive list of the operating data can be collected by connecting a VRV Checker to each system and recording a minimum of one hour operation data for analysis. This data should be sent back to Daikin

Airconditioning UK Ltd FQS department for analysis

• Operate the whole system in cooling for ½ hour and in heating for ½ hour to collect representative data

• Send data to Daikin Airconditioning UK Ltd FQS department for analysis

• System history check – although the new VRV-Q system is designed to re-use existing pipework and in some cases existing indoor units it is still necessary to know the existing systems operational history to judge its integrity for the new application

• Check for presence of leak protection dye and acid level – use total test kit

• Ensure that no Acid Away chemical has ever been added to the system refrigerant charge

• Existing system controls – investigate currently installed local controls, centralised controls and connection to the third party systems. This is particularly necessary if any existing controls are planned to be re-used

Commissioning

Dependant on the requirement, either an approved engineer or Daikin

Airconditioning UK Ltd will provide system commissioning on the completed installation. As mentioned in the warranty section above, a completed log book will need to be submitted to activate the warranty

Commissioning where not provided by Daikin Airconditioning UK Ltd, can only be completed by an approved engineer

Where Daikin Airconditioning UK Ltd provides commissioning as part of the package this shall include:

• Check installation of new units – ensure new piping is installed correct to

Daikin specification

• Check power supplies – local isolators, MCB rating

• Fill in model number data, serial numbers etc. to commissioning log book

• Initialise VRV System and ensure all units communicate

• Set up additional control systems – ITC, Bacnet and provide demonstration

• Charge additional refrigerant

• Perform “Test” operation – including “Automatic” charging function

• Connect service checker and monitor operation – Cool>Heat>Heat Recovery

• Complete Commissioning Log Book

• Provide additional comments and recommendations if necessary

• Leave operation set as required by client

Prior to our site attendance the following shall be completed:

• All communication wiring is complete and terminated correctly

• All electrical work is complete and correct (supply wiring type and size –

Breaker size correct)

• All systems piping has been pressure tested to 33 Bar

• All systems piping has been evacuated to < 5 Torr

• All systems piping has been measured and is available for our information

• Sufficient additional refrigerant is available on the day

Any other works other than those detailed above are excluded.

DNSS (Daikin Network Service System)

Where Daikin Airconditioning UK Ltd provide DNSS this shall include the following items:

• Commissioning of DNSS system (on-site service)

• GPRS router and SIM (this will be property of Daikin Airconditioning UK Ltd)

• Remote energy saving service

• 24/7 monitoring of VRV operating data

• Instant notification of system malfunction (email) 7 days a week

• Malfunction prediction service (during office hours 09.00 - 17.30)

• Bi-annual energy saving report indicating electricity cost saving and reduction in CO

2

emissions

• Recommendations to improve operating settings

• Issue of a DNSS user pack

All of the above will be provided for the warranty period of the VRV (either 3 or 5 years) depending on the package selected.

Prior to our site attendance the following shall be completed:

• A device compatible with DNSS is installed on site – Daikin Intelligent Manager,

Daikin Intelligent Touch Controller or Daikin LC controller. (Not included in the price of the monitoring package)

• All electrical work is complete and correct (supply wiring type and size –

Breaker size correct) also F1/F2 communications are installed

• A full set of as installed drawings are available – indicating system configurations, installation locations and room references

• A power source is installed for the GPRS modem near the control device –

This can be powered from a standard socket

• A connection to the internet is available – for areas where there is poor GPRS coverage a LAN or analogue phone connection must be installed near the control device. (Installation and rental costs are not included in the price of the monitoring package)

• Full access must be made available to the VRV equipment and if any access equipment is required Daikin UK must be informed prior to the site visit

• A list of contacts must be issued to Daikin Airconditioning UK Ltd (these are the contacts that should be e-mailed or telephoned in the event of a malfunction or error with the air conditioning system). If these change in the future, information will be given in the user pack for how to notify Daikin

Airconditioning UK Ltd of the changes

This is an extract from the Daikin publication “Warranty and Site Services Package for VRV-Q”. Please contact your local sales office to receive a copy and obtain further information.

76 Residential, Commercial and Industrial

NEW

NEW

VRV Accessories

https://www.youtube.com/ https://www.youtube.com/

DaikinEurope

• Price competitive mini BMS

• Cross-pillar integration of Daikin products

• Integration of third party equipment

with full integration across all product pillars

System overview

Web Access

Web Access

Integration of third party equiqment

Fire alarm

Fire alarm kWh meter kWh meter

BACnet protocol

Di/Pi line

Max. 200m

Max. 200m

Lighting

Lighting

Fan

Fan

Pump

Pump

Sensor

Sensor

Multi state objects

Multi state objects

224

224

ECPEN15-200.indd 224

ECPEN15-200.indd 224

Elevator Air handling unit

Elevator Air handling unit

Alarm

Alarm

Internet

Internet

Extranet

3G http interface http interface

WAGO interface

DCM601A51

DCM601A51

Split

Split indoor units,

ITM plus adaptor line

ITM plus adaptor line

Full control of Daikin

HVAC-R portfolio

Max. 7 adapters adapters

Di/Pi port

Di/Pi port

DCM601A52

DCM601A52 air handling units

Price List 2015 77

12/02/15 11:47

12/02/15 11:47

• Price competitive mini BMS

• Cross-pillar integration of Daikin products

• Integration of third party equipment

• Integration of third party equipment

NEW

Mini Building Management System

NEW

NEW

Mini Building Management System

NEW

User friendly

User friendliness

> Intuitive user interface

User friendliness

User friendliness unit main functions

› Visual lay out view and direct access to indoor unit

› All functions direct accessible via touch screen main funtions

NEW

NEW

NEW

NEW

› All functions direct accessible via touch screen or via web interface

Smart energy management

Smart energy management

> Helps to detect origins of energy waste

› Powerful schedules guarantee correct operation

› Powerful schedules guarantee correct operation throughout the year throughout the year

› Save energy by interlocking A/C operation with other

Flexibility

Flexibility

Flexibility

› Cross-pillar integration (heating, air conditioning, air conditioning, applied systems, refrigeration,

› I/O for integration of equipment such as lights,

NEW

pumps… on WAGO modules

› Modular concept for small to large applications

› Modular concept for small to large applications

› Control up to 512 indoor unit groups via one ITM

Easy servicing and commissioning

Easy servicing and commissioning

Easy servicing and commissioning

› Remote refrigerant containment check preventing

Easy servicing and commissioning

› Simplifi ed troubleshooting

› Save time on commissioning

› Auto registration of indoor units

› Auto registration of indoor units pre-commissioning tool

> Auto registration of indoor units

Split

Split

Split

Flexibility in size

number

number

number of groups

Fan coils

Fan coils

Fan coils

Plug & play

Plug & play

Plug & play

Chillers and AHU Refrigeration

Chillers and AHU Refrigeration

Chillers and AHU Refrigeration

Functions overview

Functions overview

Functions overview

78

Control Connectable to Connectable to

> Web access

Languages

Distribution (option)

> Operational history

› Web access

› Power Proportional

(malfunctions, operation hours, …)

> Interlock control

Control

Control

schedule, yearly calender,

> Chillers (via POL638.70 controller)

>

(2,560 groups)

NEW

NEW

NEW

Connectable to

- DX Split, Sky Air, VRV

- Chillers (via POL638.70 controller)

- Fan coils

- Daikin Altherma Flex type

› Smart energy management

System layout

waste

System layout

according to plan

- detect origins of energy waste

>

NEW

> WAGO Interface

› Temperature limit

WAGO Interface

NEW

NEW

NEW

- Air curtains

- BACnet protocol be controlled

(ITM plus Integrator + 7 iPU › Sliding temperature

WAGO Interface

› Modular integration of 3rd party equipment

› Ethernet TCPIP

Residential, Commercial and Industrial

- WAGO coupler (interface between WAGO and Modbus)

- Di module

- Do module

- Thermistor module

225

225

225

ECPEN15-200.indd 225

ECPEN15-200.indd 225

12/02/15 11:47

12/02/15 11:47

BS-Q-A

VRV IV Branch Selector Boxes – Heat Recovery

The new VRV IV Heat Recovery series has a new range of BS boxes, which are designed to offer unrivalled flexibility – enabling you to install and adapt the systems in as little time, effort and cost as possible.

BS1Q10,16,25A BS4Q14A BS6,8Q14A

Main Features:

> Unlimited unused ports

> Smaller, lighter and quieter than comparable products

> Fan coils up to 140 class can be attached to a single port

BS10,12Q14A BS16Q14A

During 2015 some systems will be moving from using VRV III BS boxes to VRV IV BS box compatibility. VRV IV Air cooled systems all use VRV IV boxes however particular care should be taken with RWEYQ-T Water cooled and VRV-Q Heat Recovery systems.

Please check with Daikin UK to ensure that you are considering using the correct BS unit series for your project.

Single Boxes for VRV IV Heat Recovery (REYQ*T)

H x W x D Dimensions

Weight

Total Indoor Capacity

Number of Fan Coil Units

Electrical Details

Piping Limits

Piping Connections Indoor

Piping Connections Outdoor

Power Supply

Power Input

Fuse Rating

Level Difference

Maximum Length

Liquid

Gas

Liquid

Suction

Discharge

Trade Accessory Price

mm kg

Phase kW amps m m inches inches inches inches inches

BS1Q10A

12

15 ~ 100

6

3/8

5/8

3/8

5/8

1/2

£337.00

Single Boxes

BS1Q16A

207 x 388 x 326

12

100 ~ 160

8

1 Phase, 220 - 240V, 50Hz

0.005

15

Data Book

3/8

5/8

3/8

5/8

1/2

£372.00

BS1Q25A

15

161 ~ 250

8

3/8

7/8

3/8

7/8

3/4

£427.00

Multi Boxes for VRV IV Heat Recovery (REYQ*T)

Dimensions

Weight

Branches per box

Piping Connections Outdoor

H x W x D

Capacity index of each branch

Number of Fan Coil Units per branch

Total Indoor Capacity Index

Total number of Fan Coil units per box

Electrical Details Power Supply

Power Input

Piping Limits

Piping Connections Indoor

Fuse Rating

Level Difference

Maximum Length

Liquid

Gas

Liquid

Suction

Discharge

Trade Accessory Price

Accessories:

Accessory Ref

KHRP26A250T

KHFP26M224

KHFP26A100C mm kg

Phase kW amps m m inches inches inches inches inches

BS4Q14AV1

298 x 370 x 430

17

4

400 or less

20

0.043

15

3/8

5/8

3/8

7/8

3/4

£1,550.00

Description

Junction pipe kit to link two Multi BS ports to connect 20 and 25kW fan coils

Stop valve kit for multi BS box future expansion without refrigerant recovery

Pipe closing kit for unused ports

Multi Boxes

BS6Q14AV1 BS8Q14AV1

298 x 580 x 430

24

6

26

8

140 or less

5 per branch

BS10Q14AV1 BS12Q14AV1

298 x 820 x 430

35

10

38

12

600 or less

30

750 or less

60

0.064

15

40 50

1 Phase, 220 - 240V, 50Hz

0.086

15

0.107

15

0.129

15

Data Book

3/8

5/8

1/2

1 1/8

3/4

3/8

5/8

1/2

1 1/8

3/4

3/8

5/8

5/8

1 1/8

1 1/8

3/8

5/8

5/8

1 1/8

1 1/8

£2,123.00 £2,792.00 £3,357.00 £4,114.00

Trade Price

£280.00

£92.00

£45.00

BS16Q14AV1

298 x 1060 x 430

50

16

64

0.172

15

3/8

5/8

3/4

1 3/8

1 1/8

£5,008.00

Price List 2015 79

RXYSQ, RYYQ, REYQ, RWEYQ

VRV Condensing Unit – Refnet Joints

For Outdoor Units

RXYQ5P /

RXYSCQ /

RXYSQ4-6PA

RYYQ8-54T /

RWEYQ-T

2-Pipe System Refrigerant Sizing between Refnet Joints and Indoor/Outdoor Units RXYSQ / RYYQ / RWEYQ

Total Capacity of

Indoor Units

Liquid

Pipe

Suction

Pipe

Refnet

Selection

Below 62.5

1/4 1/2 KHRQ22M20T

62.5 to 162.5

3/8 5/8 KHRQ22M20T

Below 150

150 to below 200

3/8

3/8

5/8

3/4

200 to below 290

290 to below 420

420 to 639

640 and above

3/8

1/2

7/8

1 1/8

5/8 1 1/8

Please contact your local sales office for selection

Refnet Header

Refnet Header

Refnet Header

Condensing Unit Branch Kit - 2 Module RYYQ, RWEYQ

Condensing Unit Branch Kit - 3 Module RYYQ

Condensing Unit Branch Kit - 2 Module RQYQ

Condensing Unit Branch Kit - 3 Module RQYQ

KHRQ22M20T

KHRQ22M20T

KHRQ22M29T9

KHRQ22M64T

KHRQ22M64T

KHRQ22M75T

KHRQ22M29H

KHRQ22M64H

KHRQ22M75H

BHFQ22P1007

BHFQ22P1517

BHFP22P36C

BHFP22P54C

For Outdoor Units

RWEYQ8-30T /

REYQ-T

Total Capacity of

Indoor Units

Below 150

3-Pipe System Refrigerant Sizing between Refnet Joints and Indoor/Outdoor Units REYQ / RWEYQ

Liquid

Pipe

3/8

150 to below 200

200 to below 290

290 to below 420

420 to 639

640 and above

3/8

3/8

1/2

5/8

5/8

3/4

3/4

1 1/8

Please contact your local sales office for selection

Refnet Header

Refnet Header

Refnet Header

Condensing Unit Branch Kit - 2 Module REYQ, RWEYQ

Condensing Unit Branch Kit - 3 Module REYQ, RWEYQ

Condensing Unit Branch Kit - 2 Module RQEQ

Condensing Unit Branch Kit - 3 Module RQEQ

Condensing Unit Branch Kit - 4 Module RQEQ

Discharge

Pipe

1/2

Suction

Pipe

5/8

3/4

7/8

1 1/8

1 1/8

Refnet

Selection

KHRQ23M20T

KHRQ23M20T

KHRQ23M29T9

KHRQ23M64T

KHRQ23M64T

KHRQ23M75T

KHRQ23M29H

KHRQ23M64H

KHRQ23M75H

BHFQ23P907

BHFQ23P1357

BHFP26P36C

BHFP26P63C

BHFP26P84C

Trade Price

£42.00

£42.00

£55.00

£58.00

£58.00

£72.00

£157.00

£190.00

£267.00

£145.00

£293.00

£164.00

£333.00

£442.00

Trade Price

£29.00

£29.00

£29.00

£29.00

£36.00

£38.00

£38.00

£48.00

£114.00

£139.00

£182.00

£78.00

£153.00

£96.00

£191.00

80 Residential, Commercial and Industrial

VRV Accessories

Remote Controllers (supplied loose)

VRV Remote Control Options Model

Hard Wired Controllers

BRC1E52A

BRC2E52C

Description

Premium wired remote controller with full text menu,

Energy features and 7 Day Time Clock

Wired Simplified remote controller

NEW

UK.BRC2E/CHROME/POL

Polished chrome simplified controller, recessed in wall

UK.BRC2E/CHROME/BRU

Brushed chrome simplified controller, recessed in wall

UK.BRC2E/BRA/POL

Polished brass simplified controller, recessed in wall

Related Fan Coil

All

All

All

All

All

BRC3E52C

Simplified Remote Controller (without heat/cool button) All

£80.00

UK.BRC3E/CHROME/POL

Polished chrome simplified controller, recessed in wall

(without heat/cool button)

UK.BRC3E/CHROME/BRU

Brushed chrome simplified controller, recessed in wall

(without heat/cool button)

All

All

£180.00

£180.00

Infra Red controllers

BRC4C61

BRC4C62

BRC4C65

BRC7C58

BRC7C52

BRC7E618

BRC7F530W

BRC7F530S

BRC7EB530W

BRC7FA532F

BRC7G53

UK.BRC3E/BRA/POL

Polished brass simplified controller, recessed in wall

(without heat/cool button)

BRP7A51/UK.FB2

All

£180.00

Digital input adaptor for Key card and Window switch contacts with programmable logic

For use with Simplified controllers

£85.00

Wireless remote controller

Wireless remote controller

Wireless remote controller

Wireless remote controller

Wireless remote controller

Wireless remote controller

Wireless remote controller for White Ceiling Decoration Panel

Wireless remote controller for Silver Ceiling Decoration Panel

Wireless remote for Fully Flat Cassette Old Style Decoration Panel

Wireless remote controller

Wireless remote controller

FXKQ-MA

FXDQ-M9 FXDQ-A, FXSQ-A, FXMQ-MA

FXMQ-P7, FXLQ-P, FXNQ-A

FXUQ-A

FXCQ-A

FXAQ-P

FXZQ-A + BYFQ60CW

FXZQ-A + BYFQ60CS

FXZQ-A + BYFQ60B3

FXFQ-A

FXHQ-A

£135.00

£135.00

£152.00

£152.00

£152.00

£135.00

£152.00

£152.00

£152.00

£152.00

£152.00

Price List 2015 81

Trade Price

£76.00

£80.00

£180.00

£180.00

£180.00

VRV Accessories

Control and BMS Interfaces (supplied loose)

VRV Control and BMS Interfaces

NEW

Interface Method

Control Protocol

0-10 Volt control

Resistance control

Control Functions

On/Off

SetPoint

Operating Mode

Fan Speed

Louver Setting

VAM Damper control

Control Prohibit / Restrict settings

Temperature SetPoint Limits

Scene Creation

Monitoring Functions

On/Off

Temperature Set Point

Operating Mode

Thermostat On

Fan Operation

Louvre Position

Fault

Fault Code

Remote Controller temperature

Remote Controller Mode

Number of Units

Return Air Temperature (Average/Min/Max)

Coil In/Out temperature

Filter Alarm

Defrost Operation

Integral Functions (BMS system not req’d)

Temperature Set Back

Temperature Setpoint Limitation

Key Card + Window Contact

Heating Interlock

Run / Standby

KRP2A52

System

Daikin

-

4

-

-

4

-

-

-

-

4

-

-

-

-

-

-

-

4

4

4

4

-

-

-

-

-

-

-

-

-

-

-

-

4

-

-

-

-

4

-

-

-

-

-

-

-

4

4

4

4

-

-

-

-

-

-

KRP4A53 RTD-NET

Unit/Group Unit/Group

Daikin Modbus

-

4

-

-

-

-

-

-

Prices

Interface

Trade Price

KRP2A52

£177.00

KRP4A53

£67.00

RTD-NET

£165.00

Associated Items

Mounting Box

(FXFQ, FXCQ, FXZQ, FXUQ, FXHQ, FXDQ, FXAQ)

Trade Price

Expansion PCB for additional unit connection

Trade Price

UK.FB2

£25.00

-

-

82 Residential, Commercial and Industrial

UK.FB2

£25.00

-

-

UK.FB2

£25.00

-

-

4

4

4

4

4

4

4

4

-

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

-

-

-

-

-

4

4

4

4

4

4

4

4

-

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

-

4

-

4

4

RTD-10

Unit/Group

Modbus -

-

-

4

4

RTD-10

£210.00

UK.FB2

£25.00

-

-

4

4

4

4

4

4

4

-

-

4

-

-

-

-

-

-

-

4

-

-

-

-

-

4

-

4

-

4

4

RTD-20 RTD-HO KLIC-DI

Unit/Group Unit/Group Unit/Group

Modbus Modbus KNX

4

4

-

-

-

-

DMS504B51 DMS502A51 EKMBDXA

System

LONWorks

-

-

System

BACnet

-

-

System

Modbus

-

-

4

4

4

4

4

4

4

4

-

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

-

-

4

4

4

4

4

-

4

4

-

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

-

-

UK.FB2

£25.00

UK.FB2

£25.00

-

-

4

4

4

4

4

-

-

4

4

RTD-20

£226.00

RTD-HO

POA

KLIC-DI

£185.00

DMS504B51 DMS502A51 EKMBDXA

POA POA POA

-

-

-

-

4

4

4

-

4

4

4

4

-

-

4

-

-

-

-

-

-

-

-

-

-

-

-

-

4

4

4

4

-

-

4

-

-

4

4

4

-

4

4

4

-

-

4

-

4

-

-

-

-

-

-

-

-

-

-

-

-

-

4

4

4

4

4

4

4

-

4

4

4

4

4

4

-

4

4

4

4

4

-

4

-

-

-

-

DAM411B51

POA

-

-

-

-

-

-

-

-

-

4

4

4

4

-

4

4

4

4

4

4

4

4

4

4

4

4

4

4

-

4

4

-

VRV Accessories

RTD-20 Control Panels

Control Panels have been developed to allow easy installation of the RTD-20 into end-user premises.

A typical application would require 1 RTD-20 per zone within a building. The control panels are pre-configured for up-to 8 different zones, making installation and wiring much simpler for the installer.

Model Description

UK.ENC/RTD-20X1

UK.ENC/RTD-20X2

UK.ENC/RTD-20X3

UK.ENC/RTD-20X4

UK.ENC/RTD-20X5

UK.ENC/RTD-20X6

UK.ENC/RTD-20X7

UK.ENC/RTD-20X8

Accessories for RTD-20 Control Panels

UK.RTD-EXTSEN

UK.RTD-INTSEN

UK.RTD-CABLE

UK.RTD-PIR/7.5M

UK.RTD-PIR/15.0M

Enclosure for RTD20 x 1

Enclosure for RTD-20 x 2

Enclosure for RTD-20 x 3

Enclosure for RTD-20 x 4

Enclosure for RTD-20 x 5

Enclosure for RTD-20 x 6

Enclosure for RTD-20 x 7

Enclosure for RTD-20 x 8

Description

Air Curtain External Sensor

Internal Sensor for RTD Device

RS485 Cable for wiring RTD Devices 100m Roll

PIR Sensor & 7.5M Cable Assy

7.5m Extension Cable for UK.RTD-PIR/7.5M

Trade Price

RTD-20 Control Panels are sold at listed price.

No discounts will apply.

£300.54

£765.54

£1,010.81

£1,256.08

£1,576.35

£1,826.62

£2,071.89

£2,317.16

Trade Price

£19.95

£12.50

£60.90

£54.00

£21.45

VRV Accessories

Centralised Control Solutions

Model Description

DCS601C51

Intelligent touch controller for up to 64 fan coil units

Related Unit Trade Price

All units with F1, F2 wiring connection

£1,641.00

KJB411A

Recessed Fixing box for I-Touch controller DCS601C51

£69.00

DCS302A52

Adaptor PCB for external on/off control of I-Touch controller and I-Touch Manager DCS601C51

£104.00

DTA103A51

Adaptor PCB for on/off control of external device from I-Touch controller and I-Touch manager DCS601C51

£305.00

UK.IC Config

I-Touch controller - off site configuration charge (please contact your sales office for info/prices) DCS601C51

POA

Price List 2015 83

VRV Accessories

Centralised Control Solutions

Model Description

DCM601A51

I-Touch manager central touch screen controller, with integral web server and email function

Related Unit Trade Price

All units with F1, F2 wiring connection

£2,262.00

DCM601A52

I-Touch manager Expansion Module for up to 64 fan coil units and 4 x kWh Meters

All units with F1, F2 wiring connection

£707.00

DCM002A51

Proportional Power Distribution add-on for I-Touch manager.

Provides ability for tenant billing

DCM601A51

POA

DCM008A51

Energy Navigator Software for I-Touch manager.

For on screen energy monitoring

DCM601A51

£658.00

DCS302A52

Adaptor PCB for external on/off control of I-Touch controller and I-Touch Manager

DTA103A51

Adaptor PCB for on/off control of external device from I-Touch controller and I-Touch manager

DCS601C51

DCS601C51

£104.00

£305.00

WAGO Interface

System

Modular interface system for connection to 3rd Party devices such as lights, pumps,

PIR sensors, access card readers, etc. Enables the iTM to control external devices and provide customised interlocks for automation and energy saving logic

DCM601A51

UK.IMAN/CONFIG1

UK.IMAN/CONFIG2

UK.FS1

I-Manager Off site configuration per FCU

I-Manager Off site configuration & graphical layout per FCU.

(Allow 4 weeks from order to delivery)

On site commissioning for PPD or Energy Navigator Software

UK.IMAN/SITE TRAIN

On Site customer training for I Touch Manager System

84 Residential, Commercial and Industrial

DCM601A51

DCM601A51

DCM601A51

DCM601A51

POA

POA

POA

POA

POA

VRV Accessories

Fan Coil Accessories (supplied loose)

Model

BYCQ140DG

BYCQ140DW

BYFQ60CS

BYFQ60B3

Description

Roundflow cassette decoration panel with self cleaning filter

Roundflow cassette decoration panel - white with white louvres

Fully Flat Cassette Decoration Panel - Silver

Fully Flat Cassette Decoration Panel - Old Style (FXZQ-MA style)

KDBHQ55B140

Sealing member for air discharge outlet

BDBHQ44C60

Sealing member for air discharge outlet - Fully Flat cassette

KDDQ50A140

Fresh air intake kit for up to 20% fresh air

Return Air filters are available - contact your branch for details

UK.RAC

UK.SAF

Return Air filters are available - contact your branch for details

Filter frame and filter

UK.FF8

KRCS01-4

Remote room mounted temperature sensor

Remote room mounted temperature sensor

KRCS01-1

K.RSS

RS-SE

Wireless room mounted temperature sensor and receiver

Service and Configuration Tool for K.RSS

Related Unit

FXFQ-A

FXFQ-A

FXZQ-A

FXZQ-A

FXFQ-A

FXZQ-A

FXFQ-A

FXHQ-A

FXMQ200 to 250

All

£146.00

FXFQ-A, FXZQ-A, FXQC-A, FXHQ-A,

FXUQ-A, FXSQ-P, FXMQ-P7, FXDQ-A

FXKQ-MA, FXDQ-P9, FXMQ-MA,

FXAQ-P, FXLQ-P, FXNQ-P

£42.00

£46.00

£89.00

All

£93.00

£233.00

£158.00

POA

POA

Trade Price

£310.00

£160.00

£198.00

£170.00

£90.00

£91.00

Condensing Unit Accessories (supplied loose)

Model

BRP2A81

Description

Adaptor PCB for Heat Cool selection terminals

KRC19-26

EKPCCAB1

UK.CGL

Strip & Rebuild of Condensing Units

Related Unit

RYYQ - REYQ-T

Cool/Heat selector switch (BRP2A81 required)

VRV Configurator Software Connection cable.

Software available from Daikin Extranet

Condensing Unit Guard size 100-140 including RXYSQ

VRV Condensing Units stripped down for delivery to site where lifting into position is difficult with traditional methods. Units are rebuilt on site by Daikin UK Engineers and fully tested

RYYQ - REYQ-T

RYYQ - REYQ-T

Trade Price

£102.00

£32.00

£180.00

£354.00

POA

Price List 2015 85

VRV Refrigerant Leak Detection System

Refrigerant leak detection systems can be required by the Safety of Building Occupants , BS-EN378.

Daikin has a solution that can help meet requirements for leak detection within enclosed spaces.

Refrigerant Leak Detection Alarm

1) The standard BS-EN378 requires that systems containing R410a refrigerant gas such as VRV, meet the requirements regarding maximum system refrigerant volumes that could leak within Hotel Bedroom or other similar Category Class A spaces. If these limitations are exceeded there must be an alarm system installed within each room where this limit is not met. The alarm system must alert the occupier through both audible and visual indication, and must also alert building staff such as supervisors, night porters etc. There is no specific requirement for the alarm system to be linked to the refrigerant system to pump down or stop the operation, although this can be configured if required by the client.

Model Description Related Unit Trade Price

UK.IAM1

Room based refrigerant gas detector with remote room mounted stainless steel facia plate. Provides local audible and visual alarm notification. Terminals for connection to alarm network and optional connection to VRV Fan coil to force system shut down

All

£279.00

UK.IAM2

Network alarm hub for connection of up to 16 room alarms. Hub can be connected in a pyramid formation of 16 groups back to a single unit for connection to a central alarm indicator panel (UK.IAMC)

All

£550.00

UK.IAMC

Alarm buzzer and lamp panel for mounting in a central building supervisor location All

£388.00

It is recommended that guidance on the selection and installation of these systems is obtained from your local Daikin UK sales office.

86 Residential, Commercial and Industrial

Daikin UK Price List 2015

Ventilation

VAM / VKM 88

Scotland

Region

0845 641 9330

Northern

Region

0845 641 9340

Midlands

Region

0845 641 9370

Western

Region

0845 641 9320

North

London

0845 641 9360

South

London

0845 641 9355

Ventilation

With the advent of new building regulations, greater awareness of increasing energy costs and a responsibility towards environmental issues, modern commercial spaces are insulated better than ever.

Double glazing, thicker insulation and draught exclusion of course, help considerably towards reducing heating/cooling demand and burdens on the environment.

The down-side however, is that these same commercial spaces have now become, in effect, sealed boxes with little or no replenishment of the air.

Daikin offers a variety of solutions for the provision of fresh air ventilation to offices, hotels, stores and other commercial outlets.

Heat Reclaim Ventilation

Correct ventilation is a key component of climate control in buildings, offices and shops. In its basic function, it ensures a flow of incoming fresh air and outgoing stale air. Our HRV (heat reclaim ventilation) solution can do much more. It can recover heat and OPTIMISE THE BALANCE BETWEEN INDOOR AND OUTDOOR

TEMPERATURE AND HUMIDITY, thus reducing the load on the system and increasing efficiency.

VAM / VKM

Total Heat Exchanger

Dimensions Height mm

Weight

Duct Connections

Air Flow Rate

External Static

Pressure

Sound Pressure

Level (Heat

Exchange Mode)

Electrical Details

Width

Depth

Ultra-High

High

Low

Ultra-High

High

Low

Ultra-High

High

Low

Power Supply

Pa

Pa dBA dBA dBA

V

Hz

Phase

Running Current A

Max Fuse Size A mm mm kg mm m

3

/hr m

3

/hr m

3

/hr

Pa

VAM150FA VAM250FA VAM350FB VAM500FB VAM650FB VAM800FB VAM1000FB VAM1500FB VAM2000FB VKM50G VKM80G VKM100G

285 301 364 726 387

1004 1514 1764

100Ø

150

150

110

69

39

20

28.5

776

525

24

150Ø

250

250

155

64

39

20

29.0

150Ø

350

350

230

98

-

-

32.0

828

816

33

200Ø

500

500

350

98

-

-

33.0

200Ø

650

650

500

93

-

-

34.5

868

52

250Ø

800

800

670

137

-

-

36.0

1156

64

250Ø

1000

1000

870

157

-

-

36.0

868

131

350Ø

1500

1500

1200

137

-

-

39.5

1156

152

350Ø

2000

2000

1400

137

-

-

40.0

832

96

200Ø

500

500

440

180

150

110

39.0

109

250Ø

750

750

640

170

120

80

41.5

1214

114

250Ø

950

950

820

150

100

70

41.0

27.5

21.5

27.0

22.0

31.5

23.5

31.5

24.5

33.0

27.0

34.5

31.0

35.0

31.0

38.0

34.0

38.0

35.0

37.0

35.5

39.0

37.0

39.0

36.5

230

50

1

0.9

15

0.9

15

0.9

15

1.3

15

1.6

15

2.5

15

3.0

15

5.0

15

5.0

15

3.8

15

3.8

15

3.8

15

Trade Unit Price £430.00

£514.00

£681.00

£872.00 £1,067.00 £1,257.00 £1,441.00 £2,201.00 £2,871.00 £2,089.00 £2,536.00 £3,016.00

Optional Accessory Compatibility

Inlet Heater Battery+

Air Filter

VAM150FA

VH1B

-

VAM250FA

-

VH2B

VAM350FB VAM500FB

EKAFV50F*

VH3B

VAM650FB VAM800FB

EKAFV80F*

VAM1000FB

VH4B or VH4/AB

EKAFV100F*

VAM1500FB

=+ Heater battery does NOT require PCB adaptor to connect to VAM

* available in Medium M6, Fine F7 and Fine F8. Only one filter is required to cover the whole of one side of the heat exchanger, even if the heat exchanger has two sections.

VH5B

VAM2000FB

2 x EKAFV100F*

Optional Inlet Heater Battery

Capacity

Duct Diamater

Trade Unit Price

kW mm

VH1B

1

100

£590.00

VH2B

1

150

£596.00

VH3B

1

200

£600.00

VH4B

1.5

250

£650.00

VH4/AB

2.5

250

£644.00

VH5B

2.5

350

£650.00

Accessories:

Accessory Ref

BRC1E52A

KRP2A52/UK.FB2

RTD-Net/UK.FB2

RTD-20/UK.FB2

BRP4A50

KRP50-2

BRP4A50A

EKAFV50F6

EKAFV50F7

EKAFV50F8

EKAFV80F6

EKAFV80F7

EKAFV80F8

EKAFV100F6

EKAFV100F7

EKAFV100F8

BRYMA65

BRYMA100

BRYMA200

Description

Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock

System adaptor PCB for remote on/off, status indication and temperature setting

Modbus Interface PCB for Sky Air and VRV

Energy control PCB for Sky Air and VRV

PCB Adaptor for VAM-A series connection to 3rd party heater

PCB Adaptor for VAM-A series connection to humidifier

PCB Adaptor for VAM-B Series connection to 3rd party heater or humidifier

Air filter for VAM350 / 500FB : Medium M6

Air filter for VAM350 / 500FB : Fine F7

Air filter for VAM350 / 500FB : Fine F8

Air filter for VAM650 / 800FB : Medium M6

Air filter for VAM650 / 800FB : Fine F8

Air filter for VAM650 / 800FB : Fine F7

Air filter for VAM1000 / 2000FB : Medium M6

Air filter for VAM1000 / 2000FB : Fine F7

Air filter for VAM1000 / 2000FB : Fine F8

CO2 Sensor for VAM350 / 500 / 650

CO2 Sensor for VAM800 / 1000

CO2 Sensor for VAM1500 / 2000

Trade Price

£76.00

£202.00

£190.00

POA

£94.00

£107.00

£118.00

£51.00

£57.00

£62.00

£57.00

£62.00

£68.00

£87.00

£93.00

£98.00

£376.00

£376.00

£376.00

Notes: i) Please contact your local sales office for required options when combined operation with an air conditioning system is required ii) Optional silencers, high efficiency filters etc are available. Prices and details on request iii) VKM models must be connected as the slave indoor unit of a standard

VRV indoor unit and share the same

BRC1D52 remote controller and BSVQ unit

( If connected to Heat Recovery) iv) UK.VH-CK VAM EHBX24 conversion kit cable included

New CO

2

sensors for VAM-FB range minimise running costs using

CO

2

sensors to deliver only the ventilation amounts required to maintain your indoor air quality

88 Residential, Commercial and Industrial

Daikin UK Price List 2015

Heating

Domestic Heating

90

Air-Water Heat Pump

Hybrid Heat Pump

91

101

Heat Emitters

Solar Thermal

Underfloor Heating

106

108

122

As of the 26th September 2015 certain heating products are subject to the Energy Labelling Directive. The corresponding energy labels will be displayed at the following web site www.daikin.co.uk

Scotland

Region

0845 641 9330

Northern

Region

0845 641 9340

Dedicated Heating Line: 0845 641 9070

Midlands

Region

0845 641 9370

Western

Region

0845 641 9320

North

London

0845 641 9360

South

London

0845 641 9355

Daikin heating systems

*

As a leading heating supplier, Daikin’s product portfolio comprises a wide range of highly energy efficient renewable energy systems, providing the right heating solution for any application and requirement.

Daikin Altherma air-water heat pump is a renewable energy heating and hot water solution, ideally suited for the UK housing market. Using renewable air as a heat source and heat pump technology with Daikin’s advanced inverter compressor technology, Daikin Altherma delivers high seasonal efficiencies, low running costs and reduced carbon emissions compared to traditional systems. Launched in 2006 with over 200,000 installed across Europe, Daikin Altherma is the leading air-water heat pump.

Daikin Altherma offers the most comprehensive and flexible range of air-water heat pumps in the market today, suitable for houses, flats and both new build and refurbishment projects. The range is available in Low Temperature (Split and Monobloc) and High

Temperature. Daikin Altherma High Temperature is an industry first system that can deliver water temperatures of up to 80°C, providing an ideal solution for boiler replacement in harder to treat properties.

Daikin solar thermal systems can be combined with Daikin

Altherma to provide a fully integrated renewable energy solution.

Daikin Altherma and Daikin solar thermal systems are recognised renewable energy solutions that can reduce hot water energy costs by up to 60% compared to traditional fossil fuel systems.

The majority of Daikin Altherma air water heat pumps* are certified by the Microgeneration Certification Scheme (MCS) and the Daikin solar thermal collectors have Solar Keymark approval and therefore are eligible for the domestic RHI. Please check the MCS website for the latest list of accredited Daikin Altherma air-water heat pumps.

Daikin is at the forefront of the drive for energy efficient heat pump technology, recognising that heat pumps and the use of renewable energy from the surrounding air is the answer to meet the future challenges of energy efficiency and carbon reduction targets.

Daikin renewable energy solutions provide a real alternative to current and future problems associated with conventional heating systems such as increasing primary energy costs and unacceptably high environmental impact.

MCS HP0006

MCS scheme

011-7S1016 F

Solar Keymark

* Except Daikin Altherma Flex Type

90 Residential, Commercial and Industrial

Air-Water heat pump

Daikin Altherma Air-Water heat pump is available in the following models:

Daikin Altherma Low Temperature Split 4-16kW

> Latest inverter technology, high seasonal efficiencies and low running costs

> Guaranteed operation down to -25°C

> New easy to use back lit controller

> New indoor unit with front access for easy maintenance

> Flexible siting with indoor unit and small outdoor unit which can be sited up to 30m away

Daikin Altherma Low Temperature Monobloc 6-16kW

> All key hydraulics built-in, e.g. expansion vessel and circulation pump

> Sealed refrigerant circuit with no F-gas needed for installation

Daikin Altherma High Temperature 11-16kW

> Providing flow temperatures up to 80°C

*

Daikin Altherma Flex Type 22.4-44.8kW

> For commercial heating applications

* Except Daikin Altherma Flex Type

Price List 2015 91

ERLQ-CV3

Low Temperature Split heat pump (outdoor)

Outdoor Units

ERLQ004CV3

Single Phase

ERLQ008CV3 ERLQ011CV3

Dimensions

Weight

Nominal capacity

Nominal input

COP

EER

Operation range

Sound pressure / power level

Refrigerant charge

Piping connections

Max piping length OU to IU

Power supply

Recommended fuses

Trade Unit Price

Height x Width x Depth mm

Heating (a/b)

Cooling

Heating (a/b)

Cooling

Heating (a/b)

Cooling

Heating

Cooling

Hot water

Heating

Cooling

R-410A

Liquid

Gas kg kW kW kW kW

°C

°C

°C dBA dBA kg inches inches m

A

54

4.4 / 4.2

4.17

0.87 / 1.85

1.8

5.04 / 2.27

2.32

48 / 61

48 / 63

1.45

£1,084.00

ERLQ006CV3

735 x 832 x 307

56

6.0 / 5.12

4.84

1.27 / 2.31

2.07

4.74 / 2.22

2.34

-25~25

10~43

-25~35

48 / 61

49 / 63

1.6

1/4

5/8

30

20

£1,106.00

56

7.4 / 6.13

5.36

1.66 / 2.89

2.34

4.45 / 2.12

2.29

49 / 62

50 / 63

1.6

11.2 / 9.6

11.72

2.43 / 4.57

4.31

4.60 / 2.1

2.72

51 / 64

50 / 64

1-phase / 230V / 50Hz

£1,481.00

£2,297.00

ERLQ014CV3

1345 x 900 x 320

113

14.5 / 10.8

12.55

3.37 / 5.19

5.08

4.30 / 2.08

2.47

-25~35

10~46

-20~35

51 / 64

52 / 66

3.4

3/8

5/8

50

40

£,2647.00

Nominal capacity and nominal input tested according to EN 14511 at the following conditions:

Heating a: Ambient air temperature 7°C and leaving water temperature 35°C (A7 W35) Heating b: Ambient air temperature -7°C and leaving water temperature 45°C (A-7 W45)

Cooling: Ambient air temperature 35°C and leaving water temperature 7°C (A35 W7)

Sound pressure level measured at 1m from the unit

ERLQ016CV3

16.0 / 10.9

13.12

3.76 / 5.22

5.73

4.25 / 2.09

2.29

52 / 66

54 / 69

£2,894.00

ERLQ-CW1

Low Temperature Split heat pump (outdoor)

Outdoor Units

Dimensions

Weight

Nominal capacity

Nominal input

COP

EER

Operation range

Sound pressure / power level

Refrigerant charge

Piping connections

Max piping length OU to IU

Power supply

Recommended fuses

Trade Unit Price

Height x Width x Depth mm kg

Heating (a/b)

Cooling

Heating (a/b) kW kW kW kW Cooling

Heating (a/b)

Cooling

Heating

Cooling

Hot water

Heating

Cooling

R-410A

Liquid

°C

°C

°C dBA dBA kg inches

Gas inches m

A

ERLQ011CW1

11.2 / 9.6

11.72

2.43 / 4.57

4.31

4.60 / 2.1

2.72

51 / 64

50 / 64

£2,521.00

3 Phase

ERLQ014CW1

1345 x 900 x 320

113

14.5 / 10.8

12.55

3.37 / 5.19

5.08

4.30 / 2.08

2.47

-25~35

10~46

-20~35

51 / 64

52 / 66

3.4

3/8

5/8

50

3-phase / 400V / 50Hz

40

£2,906.00

ERLQ016CW1

16.0 / 10.9

13.12

3.76 / 5.22

5.73

4.25 / 2.09

2.29

52 / 66

54 / 69

£3,177.00

Nominal capacity and nominal input tested according to EN 14511 at the following conditions:

Heating a: Ambient air temperature 7°C and leaving water temperature 35°C (A7 W35) Heating b: Ambient air temperature -7°C and leaving water temperature 45°C (A-7 W45)

Cooling: Ambient air temperature 35°C and leaving water temperature 7°C (A35 W7)

Sound pressure level measured at 1m from the unit

Features:

> This split system consists of an outdoor unit and an indoor hydrobox that can be connected to all standard low temperature radiators and underfloor heating systems

> The ERLQ-C models have extra features to withstand severe winter conditions

Notes: i) Some units are available on special request with Blygold treatment to offer additional protection in coastal environments. Please contact your local sales office for further information

92 Residential, Commercial and Industrial

EHBH / EHBX

Low Temperature Split hydrobox (wall hung)

Indoor Unit (wall hung)

Function

To use with

Dimensions

Leaving water temperature range

Pump

Expansion vessel volume

Water connections

Back-up heater fuse rating

Height x Width x Depth mm

Heating °C

Cooling

No. of speeds

°C

Diameter

3kW 1ph 230V

6kW 1ph 230V

6kW 3ph 400V

9kW 3ph 400V

A

A

A

A litres inches

EHBH04C3V

Heating Only

ERLQ004CV3

-

-

-

Single Phase

EHBH08C3V

Heating Only

EHBH16C3V

Heating Only

Single / 3 Phase*

EHBH08C9W

Heating Only

ERLQ006-008CV3 ERLQ011-016CV3 ERLQ006-008CV3

890 x 480 x 344 / 381 (including cover of user interface)

EHBH16C9W

Heating Only

ERLQ011-016CV3/W1

15~55

-

Inverter controlled

10

1 ¼ (female)

16

32**

10**

16**

Trade Unit Price £1,236.00

£1,261.00

£1,715.00

£1,272.00

£1,831.00

Trade Unit Price

Accessories:

Accessory Ref

EKPCCAB2

EKRUCL1

EKRSC1

KRCS01-1

EKRP1HBA

EKFT008CA

EKDP008C

EKHBDPC2

EKDPH008C

UK.CWB90-2

UK.CWB140-2

UK.DT1

UK.DT2

UK.CGM

UK.CGL

Indoor Unit (wall hung)

Function

To use with

Dimensions

Leaving water temperature range

Pump

Expansion vessel volume

Water connections

Back-up heater fuse rating

Height x Width x Depth mm

Heating °C

Cooling

No. of speeds

°C

Diameter

3kW 1ph 230V

6kW 1ph 230V

6kW 3ph 400V

9kW 3ph 400V

A

A

A

A litres inches

EHBX04C3V

Reversible

ERLQ004CV3

-

-

-

£1,447.00

Description

PC cable – to upload field settings from PC to unit or spare controller

Optional second user interface or remote room thermostat

Optional remote outdoor temperature sensor

Optional remote indoor temperature sensor

Optional PCB kit for remote alarm monitoring, run and fault indication, solar interlock for heat pump and bivalent operation

U-beams to mount the outdoor units for ERLQ 004-008

Drainpan and U-beams for outdoor units ERLQ 004-008

Drainpan kit for indoor units EHBX 004-016

Heater mat for drainpan (EKDP008C)

Wall mounting bracket for outdoor units ERLQ 004-008

Wall mounting bracket for outdoor units ERLQ 011-016

Condensate drip tray for use with UK.CWB90-2

Condensate drip tray for use with UK.CWB140-2

Outdoor unit guard for ERLQ 004-008

Outdoor unit guard for ERLQ 011-016

Single Phase

EHBX08C3V

Reversible

ERLQ006-008CV3

EHBX16C3V

Reversible

ERLQ011-016CV3

Single / 3 Phase*

EHBX08C9W

Reversible

EHBX16C9W

Reversible

ERLQ006-008CV3

890 x 480 x 344 / 381 (including cover of user interface)

ERLQ011-016CV3/W1

15~55

5~22

Inverter controlled

10

1 ¼ (female)

16

32**

10**

16**

£1,476.00

£1,982.00

Trade Price

£180.00

£94.00

£61.00

£46.00

£104.00

£83.00

£116.00

£112.00

£176.00

£36.00

£46.00

£54.00

£59.00

£296.00

£354.00

£1,493.00

£2,074.00

Notes: i) * Back-up heater can be re-wired as

3kW/1ph, 6kW 1ph, 6kW/3ph or

9kW/3ph ii) ** 9W models only iii) Only one optional remote sensor can be installed. Sensor connects to indoor hydrobox

Features:

> Available in heating only or heating/cooling versions

> A choice of back-up heaters 3, 6 or 9kW

> Heating / cooling hydroboxes are delivered with drain pan and insulation kit as standard

Price List 2015 93

EBHQ

Low Temperature Monobloc heat pump (6-8kW)

Outdoor Unit

Dimensions

Weight

Nominal capacity

Nominal input

COP

EER

Operation range

Sound pressure / power level

Cooling

Hot water

Heating

Cooling

R-410A Refrigerant charge (factory)

Power supply

Recommended fuses

Pump No. of speeds

Expansion vessel volume

Water connections

Max piping length OU to cylinder

Diameter

Interconnecting cable

Height x Width x Depth mm kg

Heating (a/b)

Cooling kW kW

Heating (a/b)

Cooling

Heating (a/b)

Cooling

Heating kW kW

°C

°C

°C dBA dBA kg

A litres inches m

EBHQ006BBV3

6.00 / 3.77

5.12

1.41 / 1.88

2.16

4.26 / 2.00

2.37

48 / 61

48 / 63

805 x 1190 x 360

95

-15 ~ 25

10 ~ 43

-15 ~ 35

1.7

1-phase / 230V / 50Hz

20

3

6

1 (male)

10

EKCOMCAB1 (12m) – delivered separately

EBHQ008BBV3

8.85 / 5.26

6.08

2.21 / 2.56

2.75

4.00 / 2.05

2.21

49 / 62

50 / 63

Trade Unit Price £2,000.00

£2,288.00

Nominal capacity and nominal input tested according to EN 14511 at the following conditions:

Heating a: Ambient air temperature 7°C and leaving water temperature 35°C (A7 W35) Heating b: Ambient air temperature -7°C and leaving water temperature 45°C (A-7 W45)

Cooling: Ambient air temperature 35°C and leaving water temperature 7°C (A35 W7)

Sound pressure level measured at 1m from the unit

Accessories:

Accessory Ref

EKCOMCAB1

EKMBUHB6V3

EKCBH008BCV3

EKCBX008BCV3

EKBPHT08B

EKRP1HBA

EKRTWA

EKRTR

EKRTETS

Description

Data cable (12m) Note: Must be ordered with every EBHQ 006-008

Back up heater kit (3/6kW)

Control box – heating only

Control box – heating / cooling

Bottom plate heater for outdoor units sizes 006-008 (see note)

Optional PCB kit for remote alarm monitoring, run and fault indication, solar interlock for heat pump and bivalent operation

Optional wired room thermostatic controller

Optional wireless room thermostatic controller

Floor temperature sensor for use with wireless room thermostat EKRTR

Trade Price

£60.00

£436.00

£186.00

£298.00

£77.00

£104.00

£99.00

£194.00

£14.00

Notes: i) It is strongly recommended to install the bottom plate heater in units that will be installed in a region that will experience prolonged periods below 0°C with very high humidity

Features:

> The small Daikin Altherma Monobloc is ideal for smaller properties

> In this system, water pipes, rather than refrigerant lines, run from the outdoor unit to indoors which means that no special refrigerant handling is necessary

> The back-up heater is installed indoors

For Low Temperature Monobloc (6-8kW)

Back up heater and control box

EKMBUHB6V3

Back up heater Function

To use with

Dimensions Max depth

Max width

Max height mm mm mm

170

380

575

Power supply

Recommended fuses

Water connections Diameter

A inches

32 (6kW BUH)

1 ¼

Trade Unit Price £436.00

Back up heater Control box

EKCBH008BCV3

Control box – heating only

EKCBX008BCV3

Control box – reversible

EBHQ006~008BBV3

100 (excluding user interface) / 120 (including user interface)

412

390

1-phase / 230V / 50Hz

-

-

£186.00

£298.00

94 Residential, Commercial and Industrial

EDHQ

Low Temperature Monobloc heat pump (11-16kW)

Outdoor Unit

Function

Dimensions

Weight

Nominal capacity

Nominal input

COP

EER

Operation range

Sound pressure / power level

Hot water

Heating

Cooling

R-410A Refrigerant charge (factory)

Back up heater (factory fitted)

Power supply

Recommended fuses

Pump

Expansion vessel volume

Water connections (diameter)

Max piping length OU to cylinder

Outdoor unit

6kW BUH

No. of speeds

Height x Width x Depth mm kg

Heating (a/b)

Cooling kW kW

Heating (a/b)

Cooling

Heating (a/b)

Cooling

Heating

Cooling kW kW

°C

°C

°C dBA dBA kg kW

A

A litres inches m

Single Phase 3 Phase

EDHQ011BB6V3 EDHQ014BB6V3 EDHQ016BB6V3 EDHQ011BB6W1 EDHQ014BB6W1 EDHQ016BB6W1

Heating Only Heating Only Heating Only Heating Only Heating Only Heating Only

11.2 / 6.19

1418 x 1435 x 382

180

14 / 7.72

-

16 / 8.7

11.2 / 6.19

1418 x 1435 x 382

180

14 / 7.72

16 / 8.7

2.56 / 3.21

3.88 / 4.44

2.6 / 3.11

3.31 / 3.84

3.81 / 4.39

4.38 / 1.93

3.29 / 3.76

-

4.25 / 2.05

-

-15~35

-

4.12 / 1.96

4.3 / 1.99

4.23 / 2.01

-

-15~35

-

4.2 / 1.98

51 / 64

-15~35

51 / 65

-

2.95

6

1-phase / 230V / 50Hz

32

32

2

10

1 ¼ (female)

10

52 / 66 49 / 64

-15~35

51 / 65

-

2.95

6

3-phase / 400V / 50Hz

20

20

2

10

1 ¼ (female)

10

53 / 66

Trade Unit Price £3,753.00

£4,064.00

£4,282.00

£3,951.00

£4,291.00

£4,532.00

Nominal capacity and nominal input tested according to EN 14511 at the following conditions:

Heating a: Ambient air temperature 7°C and leaving water temperature 35°C (A7 W35) Heating b: Ambient air temperature -7°C and leaving water temperature 45°C (A-7 W45)

Cooling: Ambient air temperature 35°C and leaving water temperature 7°C (A35 W7)

Sound pressure level measured at 1m from the unit

Accessories:

Accessory Ref

EKBPHTH16A

EKRP1HBA

EKRTWA

EKRTR

EKRTETS

Description

Bottom plate heater for outdoor units sizes 011-016 (see note)

Optional PCB kit for remote alarm monitoring, run and fault indication, solar interlock for heat pump and bivalent operation

Optional wired room thermostatic controller

Optional wireless room thermostatic controller

Floor temperature sensor for use with wireless room thermostat EKRTR

Trade Price

£132.00

£104.00

£99.00

£194.00

£14.00

Notes: i) It is strongly recommended to install the bottom plate heater in units that will be installed in a region that will experience prolonged periods below 0°C with very high humidity

Features:

> The Daikin Altherma Monobloc contains all components and the back-up heater in the outdoor unit

> In this system, water pipes, rather than refrigerant lines, run from the outdoor unit to indoors which means that no special refrigerant handling is necessary for installation

Price List 2015 95

EBHQ

Low Temperature Monobloc heat pump (11-16kW)

Outdoor Unit

Function

Dimensions

Weight

Nominal capacity

Nominal input

COP

EER

Operation range

Sound pressure / power level

Hot water

Heating

Cooling

R-410A Refrigerant charge (factory)

Back up heater (factory fitted)

Power supply

Recommended fuses

Pump

Expansion vessel volume

Water connections (diameter)

Max piping length OU to cylinder

Outdoor unit

6kW BUH

No. of speeds

Height x Width x Depth mm kg

Heating (a/b)

Cooling kW kW

Heating (a/b)

Cooling

Heating (a/b)

Cooling

Heating

Cooling kW kW

°C

°C

°C dBA dBA kg kW

A

A litres inches m

Single Phase 3 Phase

EBHQ011BB6V3 EBHQ014BB6V3 EBHQ016BB6V3 EBHQ011BB6W1 EBHQ014BB6W1 EBHQ016BB6W1

Reversible Reversible Reversible Reversible Reversible Reversible

1418 x 1435 x 382

180

1418 x 1435 x 382

180

11.2 / 6.19

10

2.56 / 3.21

3.69

4.38 / 1.93

2.71

14 / 7.72

12.5

3.29 / 3.76

5.39

4.25 / 2.05

2.32

-15~35

10~46

16 / 8.7

13.1

3.88 / 4.44

5.93

4.12 / 1.96

2.21

11.2 / 6.19

10

2.6 / 3.11

3.69

4.3 / 1.99

2.71

14 / 7.72

12.5

3.3 / 3.84

5.06

4.23 / 2.01

2.47

-15~35

10~46

16 / 8.7

13.1

3.81 / 4.39

5.75

4.2 / 1.98

2.28

51 / 64

50 / 65

-15~35

51 / 65

52 / 66

2.95

6

1-phase / 230V / 50Hz

32

32

2

10

1 ¼ (female)

10

52 / 66

54 / 69

49 / 64

50 / 65

-15~35

51 / 65

52 / 66

2.95

6

3-phase / 400V / 50Hz

20

20

2

10

1 ¼ (female)

10

53 / 66

54 / 69

Trade Unit Price £3,912.00

£4,219.00

£4,438.00

£4,106.00

£4,447.00

£4,688.00

Nominal capacity and nominal input tested according to EN 14511 at the following conditions:

Heating a: Ambient air temperature 7°C and leaving water temperature 35°C (A7 W35) Heating b: Ambient air temperature -7°C and leaving water temperature 45°C (A-7 W45)

Cooling: Ambient air temperature 35°C and leaving water temperature 7°C (A35 W7)

Sound pressure level measured at 1m from the unit

EKHWSU

Hot water cylinder for Low Temperature Split and Monobloc

UK.EKHWSU150B3V3

UK.EKHWSU300B3V3

Domestic hot water cylinder

Suitable for

Water volume

Max water temperature

Booster heater capacity

Power supply

Recommended fuses

Height

Diameter

Empty weight

Material inside cylinder

Piping connections (diameter) Water inlet H/E

Water outlet H/E

Cold water in

Hot water out

Trade Unit Price

litres

°C kW

A mm mm kg inch inch inch inch

150

1015

38

£1,064.00

UK.EKHWSU200B3V3

Unvented systems (EKUHWBB kit also required)

200

85

3

1-phase / 230V / 50Hz

16

1265

580

46

Stainless steel

3/4 (female)

3/4 (female)

3/4 (female)

3/4 (female)

£1,081.00

300

1715

60

£1,188.00

Accessories:

Accessory Ref

EKSOLHW + EKUHW2WB

Description

Solar connection kit for EKHWSU cylinder for connecting to solar panels (see note)

Features:

> This stainless steel unvented cylinder is the ideal partner for

Daikin Altherma Low Temperature Split and Monobloc heat pumps

> Fitted with 3kW immersion heater as standard

> Supplied with 3-way valve and G3 safety kit (EKUHWBB)

> For vented hot water cylinders, please contact your local sales office

96 Residential, Commercial and Industrial

Trade Price

£533.00

Notes: i) A specially designed kit transfers solar heat into the Daikin Altherma hot water cylinder via an external heat exchanger, which allows the entire content of the cylinder to be heated efficiently with solar heat. Price shown includes EKUHW2WB

2-way valve. Delivered with EKRP1HBA

PCB adaptor

ERSQ

High Temperature Split heat pump (outdoor)

Outdoor Unit

Dimensions

Weight

Nominal capacity

Nominal input

COP

Operation range

Sound pressure / power level

Refrigerant charge

Piping connections

Max piping length OU to IU

Power supply

Recommended fuses

Height x Width x Depth mm kg

Heating (a/b)

Heating (a/b) kW kW

Heating (a/b)

Heating

Hot water

Heating

R-410A

Liquid

Gas

°C

°C dBA kg inches inches m

A

ERSQ011AV1

11 / 11

3.03 / 3.57

3.63 / 3.08

52 / 68

Single Phase

ERSQ014AV1

1345 x 900 x 320

120

14 / 14

4.07 / 4.66

3.44 / 3.00

-20 ~ + 24

-20 ~ + 35

53 / 69

4.5

3/8

5/8

50

1-phase / 230V / 50Hz

25

ERSQ016AV1

16 / 16

4.83 / 5.57

3.31 / 2.88

55 / 71

ERSQ011AY1

11 / 11

3.03 / 3.57

3.63 / 3.08

52 / 68

3 Phase

ERSQ014AY1

1345 x 900 x 320

120

14 / 14

4.07 / 4.66

3.44 / 3.00

-20 ~ + 24

-20 ~ + 35

53 / 69

4.5

3/8

5/8

50

3-phase / 400V / 50Hz

16

ERSQ016AY1

16 / 16

4.83 / 5.57

3.31 / 2.88

55 / 71

Trade Unit Price £2,472.00

£2,789.00

£3,013.00

£2,699.00

£2,831.00

£3,345.00

Nominal capacity and nominal input tested at the following conditions: a. A7 W45 according to EN14511 b. A7 W65 according to Eurovent rating standard 6/C/003-2006

Accessories:

Accessory Ref

EKBPHTH16A

EKBUHA6V3

EKBUHA6W1

EKRP1AHT

EKRUAHTB

EKRP1HBA

EKRTWA

EKRTR

EKRTETS

UK.CWB140-2

UK.DT2

UK.CGL

Description Trade Price

Bottom plate heater for outdoor unit sizes 011-016

In line back up electric heater 6kW, 1-phase, 230V (also requires EKRP1AHT) – for space heating only

In line back up electric heater 6kW, 3-phase, 400V (also requires EKRP1AHT) – for space heating only

£132.00

£461.00

£461.00

£104.00

Optional PCB for demand control (required for EKRTW, EKRTR, EKRTETS, EKBUH*)

Remote user interface

£157.00

Optional PCB kit for remote alarm monitoring, run and fault indication and solar interlock for heat pump

£104.00

Optional wired room thermostatic controller (also requires EKRP1AHT)

£99.00

Optional wireless room thermostatic controller (also requires EKRP1AHT)

Floor temperature sensor for use with EKRTR (also requires EKRP1AHT)

Wall mounting bracket for outdoor unit ERSQ 011-016

Condensate drip tray for use with UK.CWB140-2

Outdoor unit guard for ERSQ 011-016

£194.00

£14.00

£46.00

£59.00

£354.00

Features:

> The outdoor unit extracts heat from the ambient air and transfers it to the indoor unit via refrigerant piping

> Heating only versions

> Order with matching indoor unit

98 Residential, Commercial and Industrial

EKHB

High Temperature Split hydrobox (floor standing)

Indoor Unit (floor standing)

To use with

Dimensions

Weight

Leaving water temperature range

Height x Width x Depth mm kg

°C

Refrigerant charge (factory)

Power supply

R134a kg

A Recommended fuses

Pump

Expansion vessel volume

Water connections (diameter)

No. of speeds litres inch

Trade Unit Price

Single Phase 3 Phase

EKHBRD011ACV1 EKHBRD014ACV1 EKHBRD016ACV1 EKHBRD011ACY1 EKHBRD014ACY1 EKHBRD016ACY1

ERSQ011AV1 ERSQ014AV1

705 x 600 x 695

ERSQ016AV1

144.25

25~80 without electrical heater

3.2

1-phase / 230V / 50Hz

25

Inverter controlled

12

1 (female)

ERSQ011AY1 ERSQ014AY1

705 x 600 x 695

147.25

25~80 without electrical heater

3.2

3-phase / 400V / 50Hz

25

Inverter controlled

12

1 (female)

ERSQ016AY1

£2,985.00

£3,038.00

£3,130.00

£3,045.00

£3,099.00

£3,192.00

Accessories:

Accessory Ref

EKBPHTH16A

EKBUHA6V3

EKBUHA6W1

EKRP1AHT

EKRUAHTB

EKRP1HBA

EKRTWA

EKRTR

EKRTETS

UK.CWB140-2

UK.DT2

UK.CGL

Description Trade Price

Bottom plate heater for outdoor unit sizes 011-016

In line back up electric heater 6kW, 1-phase, 230V (also requires EKRP1AHT) – for space heating only

In line back up electric heater 6kW, 3-phase, 400V (also requires EKRP1AHT) – for space heating only

Optional PCB for demand control (required for EKRTW, EKRTR, EKRTETS, EKBUH*)

Floor temperature sensor for use with EKRTR (also requires EKRP1AHT)

Wall mounting bracket for outdoor unit ERSQ 011-016

£132.00

£461.00

£461.00

£104.00

Remote user interface

£157.00

Optional PCB kit for remote alarm monitoring, run and fault indication and solar interlock for heat pump

£104.00

Optional wired room thermostatic controller (also requires EKRP1AHT)

Optional wireless room thermostatic controller (also requires EKRP1AHT)

£99.00

£194.00

£14.00

£46.00

Condensate drip tray for use with UK.CWB140-2

Outdoor unit guard for ERSQ 011-016

£59.00

£354.00

Features:

> The indoor unit receives the heat from the outdoor unit and further increases the temperature up to 80°C, which is ideal for use with existing radiators

> It is designed to only be used with the integrated hot water cylinder EKHTSU

> For RHI, check maximum design flow temperature carefully

EKHTSU

Hot water cylinder for High Temperature Split

Domestic hot water cylinder

Suitable for

Water volume

Max water temperature

Litres

°C

Dimensions (cylinder only)

Dimensions (cylinder integrated on hydrobox)

Height x Width x Depth

Height x Width x Depth

Empty weight

Material inside cylinder

Piping connections (diameter) Water inlet H/E

Water outlet H/E

Cold water in

Hot water out mm mm kg mm mm inch inch

Trade Unit Price

UK.EKHTSU200AC

Unvented systems (including EKUHWHTB)

UK.EKHTSU260AC

200 260

75

1335 x 600 x 695

2010 x 600 x 695

1610 x 600 x 695

2285 x 600 x 695

70

Stainless steel

25 (female quick coupling, supplied, integrated solution)

25 (female quick coupling, supplied, integrated solution)

3/4 (female)

3/4 (female)

78

£1,113.00

£1,261.00

Accessories:

Accessory Ref

EKFMAHTB

Description

Kit for standalone installation with floor standing hydrobox

Features:

> This integrated cylinder is designed for use with Daikin Altherma HT only

> The cylinder features fast heat-up and recovery times, and low heat losses

> The indoor unit and hot water cylinder are designed to be stacked to save space, or can alternatively be installed next to each other if limited height is available for installation

> Supplied with 3-way valve and G3 safety kit (EKUHWHTB)

Trade Price

£277.00

Price List 2015 99

Air-Water heat pump combination table

Daikin have a full range of air-water heat pumps to suit many installation requirements and applications.

Use the table below to help select the right combination of equipment.

Outdoor Indoor DHW cylinder

or

Thermal store

ERLQ004-008

(page 92)

ERLQ011-016

(page 92)

EBHQ006-008 + EKCOMCAB1

(page 94)

EHBH/X04-16

(page 93) or

EKHWSU150-300B

(page 96)

EKHWP300-500B

Control box EKCBH/X

(page 94)

Back-up heater

(optional)

EKMBUH

(page 94) or

EKHWSU150-300B

(page 96)

EKHWP300-500B

EDHQ/EBHQ011-016

(page 95)

ERSQ011-016

(page 98)

100 Residential, Commercial and Industrial or

EKHWSU150-300B

(page 96)

EKHWP300-500B

EKHBRD011-016

(page 99) or

EKHTSU200-260AC

(page 99)

EKHWP300-500B

Hybrid heat pump

The Daikin Altherma Hybrid Heat Pump is unique technology. It combines a high efficiency gas combi boiler with a renewable energy air-water heat pump, all in one efficient, compact heating system.

Daikin Altherma Hybrid heat pump

The smart hybrid logic automatically selects the most energy efficient and cost-effective operation based on the user’s energy tariff, at any given temperature to make it the most efficient solution on the market.

> Suitable for heating systems requiring flow temperatures up to 80°C

> Eligible for RHI when fitted with required heat and electric meters

> Single compact indoor unit to minimise space

> No DHW tank needed – hot water delivered by combi boiler

> Suitable for LPG applications for even higher running cost savings

> Single easy to use backlit control using energy tariffs for automatic control

> All key components built in: A-label pump, expansion vessel, pressure relief

> Heat pump capacity: 5 and 8kW

> Boiler output CH 27kW (80/60) and DHW 33kW

(13 l/min at dT 35K)

> Boiler SEDBUK (2009) rated 89.1% (natural gas) and 90.1% (LPG)

> Dedicated training courses available

Price List 2015 101

EHYH/K / EVLQ

Daikin Altherma hybrid heat pump system

Indoor Unit and boiler wall hung (1 combined unit)

Indoor Unit (heat pump)

Function

To use with

Dimensions

Weight

Leaving water temperature range

Pump

Expansion vessel volume

Indoor Unit (boiler)

Function

To use with

Height x Width x Depth

Heating

No. of speeds mm kg

°C litres

Dimensions

Max dimensions

(boiler and heat pump)

Weight

Capacity (heating)

Height x Width x Depth mm

Height x Width x Depth mm

Capacity (hot water)

Leaving water temperature range

DHW flow rate dT 35K

Heating connections

DHW connections

Gas connection

IP rating

Device type

Supply pressure

Minimum

Maximum

Minimum

Maximum

Heating

Hot water

Hot water

Diameter

Diameter

Diameter

Natural gas (G20)

LPG (G31) kg kW kW kW kW

°C

°C l/min mm mm mm mbar mbar

Nox class

Flue gas connection

Maximum flue length, 60/100

Maximum flue length, 80/125

SEDBUK rating (2009) m m

%

EHYHBH05AV32

Heating Only

EVLQ05CV3

30

1075 x 450 x 164

25~55

Inverter controlled

10

EHYKOMB33AA2

Heating only

EHYHBH05AV32

EHYHBH08AV32

710 x 450 x 240

1075 x 450 x 405

36

7.6

27

7.6

32.7

15 ~ 80

40 ~ 65

13.1

22

15

15

IP44

C13, C33, C53

20

30-37

5

60/100

10

29

89.1 (NG) / 90.1 (LPG)

Outdoor Units

Dimensions

Weight

Nominal capacity

Nominal input

COP

Operation range (ambient)

Sound pressure / power level

Refrigerant charge

Piping connections

Height x Width x Depth mm kg

Heating

Heating kW kW

Heating

Heating

Heating

R-410A

Liquid

Gas

°C dBA kg inches inches m Max piping length OU to IU

Power supply

Recommended fuses A

Nominal capacity and nominal input tested according to EN 14511 at the following conditions:

Heating: Ambient air temperature 7°C and leaving water temperature 35°C (A7 W35)

Sound pressure level measured at 1m from the unit

EVLQ05CV3

54

4.4

0.87

5.04

48 / 61

1.45

735 x 832 x 307

-25~25

1/4

5/8

20

1-phase / 230V / 50Hz

20

EHYHBH08AV32

Heating Only

EVLQ08CV3

31.2

EVLQ08CV3

56

7.4

1.66

4.45

49 / 62

1.6

102 Residential, Commercial and Industrial

EHYH/K / EVLQ

Daikin Altherma hybrid heat pump system

Part Number

UK.HYBRID05B33

EVLQ05CV3

EHYHBH05AV32

EHYKOMB33AA2

EKRUCBL2

EKHY093467

EKVK3A

UK.HYBRID08B33

EVLQ08CV3

EHYHBH08AV32

EHYKOMB33AA2

EKRUCBL2

EKHY093467

EKVK3A

Description

Hybrid 5kW pack

This pack contains:

Outdoor unit: 5kW, 1-phase, 230V

Hydrobox: 5kW, 1-phase, 230V

Hybrid combi boiler: 33/27kW

Hybrid controller

Pipe cover plate

Hybrid valve pack

Hybrid 8kW pack

This pack contains:

Outdoor unit: 8kW, 1-phase, 230V

Hydrobox: 8kW, 1-phase, 230V

Hybrid combi boiler: 33/27kW

Hybrid controller

Pipe cover plate

Hybrid valve pack

Trade Price

£3,400.00

£3,850.00

Accessories:

Accessory Ref

K.HEATMET

K.ELECMETV

EKHY075787

EKHY090717

EKPCCAB2

EKRP1HBA

EKRUCL1

EKRSC1*

KRCS01-1*

EKFT008CA

EKDP008C

EKDPH008C

UK.CWB90-2

UK.DT1

UK.CGM

Description

Heat meter for domestic RHI (hybrid only)

Class 3 heat meter delivered with body, digital interface and 2 temperature sensors

Electric meter for RHI

IEC Class 1 electric meter to measure the electricity consumption of the Daikin Altherma heat pump

LPG conversion kit

Flue adapter 80/125

PC cable – to upload field settings from PC to unit or spare controller

Optional PCB kit for remote alarm monitoring, run and fault indication and solar interlock

Optional second user interface or room thermostat

Optional remote temperature sensor for outdoor temperature (see note)

Optional remote temperature sensor for indoor temperature (see note)

U-beams to mount the outdoor unit EVLQ05CV3

Drainpan and U-beams for outdoor unit EVLQ05CV3

Heater mat for drainpan (EKDP008C)

Wall mounting bracket for outdoor unit

Condensate drip tray for UK.CWB90-2

Outdoor unit guard

Trade Price

£170.00

£109.00

£20.00

£20.00

£180.00

£104.00

£94.00

£61.00

£46.00

£83.00

£116.00

£176.00

£36.00

£54.00

£296.00

Notes: i) * Only one optional remote sensor can be installed

Features:

> New and revolutionary hybrid heat pump system with higher efficiency and higher running cost savings than condensing boiler alone

> Boiler can be converted to run on LPG

> Delivered as a set including outdoor unit, indoor unit, boiler, controller and pipe cover plate

> Flues ordered separately

Daikin Altherma hybrid heat pump system

Hybrid Tank Connection Kits

Part Number

EKEPHT3H

EKHY3PART

EKHY3PART2

Description

Daikin thermal store (EKHWP-B)

This pack contains:

3 way valve (Honeywell)

Tank sensor (HT + adapter)

2 x isolation valves

T-piece

Third party tank – dry pocket sensor

This pack contains:

3 way valve (ESBE)

Tank sensor (LT)

Third party tank – thermostat only

This pack contains:

3 way valve (ESBE)

Wire harness

Trade Price

£174.00

£145.00

£175.00

Price List 2015 103

Daikin Altherma hybrid heat pump system

Flue accessories (60/100)

Description

Horizontal flue kit 60/100

Horizontal flue kit with low profile elbow 60/100

Extension 60/100 x 500mm

Extension 60/100 x 1000mm

Elbow 60/100, 30 degrees

Elbow 60/100, 45 degrees

Elbow 60/100, 87 degrees

Tee with inspection panel 60/100

Wall bracket DN.100

Plume Management Kit (PMK)

1

1

1

1

1

Quantity per pack

1

Part number

EKFGP1292

1 EKFGP1293

EKFGP4651

EKFGP4652

EKFGP4664

Trade Price

£43.00

£52.00

£25.00

£30.00

£33.00

EKFGP4661

EKFGP4660

£22.00

£22.00

1

25 pieces

1

EKFGP4667

EKFGP4631

EKFGP1294

£82.00

£160.00

£36.00

Flue deflector

104 Residential, Commercial and Industrial

1 EKFGP1295

£14.00

Daikin Altherma hybrid heat pump system

Flue accessories (60/100)

(Continued)

Description

PMK elbow, 87 degrees

Quantity per pack

1

Part number

EKFGP1284

Trade Price

£12.00

PMK elbow, 45 degrees

PMK extension, length 1000mm incl. bracket

Vertical roof terminal 60/100

2 pieces

1

1

EKFGP1285

£20.00

EKFGP1286

£18.00

EKFGP6837

£60.00

Weather slate (plastic) 60/100

(25-45 degrees)

1

Weather slate 60/100 18-22 degrees

23-27 degrees

43-47 degrees

48-52 degrees

53-57 degrees

Weather slate flat aluminium 60/100

1

1

1

1

1

1

Weather slate flat aluminium 60/100

(0 – 15 degrees)

1

EKFGP7910

£27.00

EKFGS0518

EKFGS0519

EKFGS0523

EKFGS0524

EKFGS0525

EKFGP6940

£90.00

£90.00

£90.00

£90.00

£90.00

£20.00

EKFGP1296

£50.00

Price List 2015 105

Heat emitters

Heat pump convectors can provide both heating and cooling if required and can be used with the Daikin Altherma heat pump to offer a compact and highly efficient solution:

> Designed to operate at low flow temperature (35°C) to optimise the efficiency of an air-water heat pump

> Quiet operation and no draughts

> Able to heat and cool

> Available in 1.5 and 2kW

> Ideal for meeting higher temperature star rating in MCS Heat Emitter Guide

106 Residential, Commercial and Industrial

FWX / EKV

Daikin heat pump convector

Part number

FWXV15A

+

EKVKHPC

FWXV20A

+

EKVKHPC

Description

Cased, low wall mount type, 2-pipe*

Cased, low wall mount type, 2-pipe*

Nominal capacity based on following conditions:

Heating: indoor temp, 20°CDB; entering water temp. 45°C, water temperature drop 5°C.

Cooling: Indoor temp. 27°CDB; entering water temp. 7°C, water temperature rise 5°C.

Features:

> The highly efficient, low noise Daikin heat pump convector is designed to provide the maximum comfort and high efficiency in combination with Daikin Altherma heat pumps

> The heat pump convector improves system efficiency compared to a combined under floor heating and radiator system and to a fan coil heating system

> The Daikin heat pump convector has been designed to work effectively at low temperatures, while retaining a compact size compared to an equivalent output radiator sized for 45°C

> The heat pump convector can easily replace existing heat emitters

> The unit is very quiet in operation and is ideal for bedroom applications

> The unit has a quiet operation mode which can be selected using the remote controller

> The sound levels are as low as 18dB(A) on 2kW system and 12dB(A) on 1.5kW system on the quiet mode

> Daikin heat pump convectors offer a solution combined with UFH systems to provide heat in areas where

UFH is difficult to integrate

> It is designed to support heating only and heating / cooling applications

> When combined with Daikin Altherma outdoor units, the heat pump convectors can be linked together for total system control, additional comfort and increased efficiency

> Additional third party controls are needed to link simple fan coil systems with Daikin Altherma heat pumps

> Delivered with individual controller and with 2-way valve

> Drain pan is included

Nominal kW (heating/cooling)

1.5 / 1.2

2.0 / 1.7

Trade Price

£491.00

£528.00

Notes: i) * Please note that EKVKHPC (2 way valve) needs to be ordered as a separate item, but price shown includes the value of this part

Price List 2015 107

Solar thermal

Daikin solar systems maximise the use of renewable free energy from the sun through high efficiency flat plate collectors. The Daikin solar thermal system is available in drainback and pressurised options and is designed to work in conjunction with Daikin Altherma air-water heat pumps for maximum efficiency. Solar panels are Solar Keymark approved and eligible for the Domestic RHI.

Drainback solar system

> The drainback solar system is a low maintenance system which does not need antifreeze agents

> It consists of an unpressurised thermal store which can be combined with Daikin Altherma heat pumps or another auxiliary heat source

> Water in the store is pumped to the solar panels, heated and returns to stratify in the Daikin thermal store

> When solar energy is not available, the solar collectors empty and water drains back to the store

Pressurised solar system

> The pressurised solar system transfers heat to the unvented cylinder via a specially designed heat exchanger kit. This allows the entire cylinder to be heated by solar energy

> During solar heating, the heat pump is disabled to ensure maximum efficiency

Standalone solar system

> The standalone solar system combines a pressurised solar system and a twin-coil unvented cylinder and is designed to be combined with an auxiliary gas boiler

> Ideal for on-gas retrofit applications

Solar pressurised Solar drainback

108 Residential, Commercial and Industrial

Solar panel

EKSV / EKSH

Type

Dimensions

Weight

Max operating pressure

Height x Width x Depth mm kg

Bar

Max standstill temp

Information for SAP assessors and for MCS installers

°C

Gross / net aperture area

Zero loss efficiency

Heat loss coefficient (a1)

Heat loss coefficient (a2)

m

2

W/m

2

.K

W/m

2

.K

2

Solar pump station

EKSRD / EKSRP

System

Dimensions

Power supply

Solar pump

Max pump power consumption

Max operating pressure

Max pump capacity

Temperature range

Connections

Height x Width x Depth mm

-

W

Bar m

3

/h

°C

Solar controller

EKSR

Dimensions

Power supply

Max electric consumption

Display

Height x Width x Depth mm

W

DHW Thermal Store

EKHWP

Storage capacity

Total volume (V)

Dedicated solar volume (Vs)

Surface area solar heat exchange coil

Heating coil capacity

Heating coil area

Pipe connections

Cold and hot water litres

Weight (empty)

Weight (filled)

Dimensions

Max storage temp kgs kgs

Height x Width x Depth mm

°C kWh/24h Heat loss at 60°C

Coil material

Potable water capacity

Max operating pressure (potable water) litres

Bar

DHW coil area

Information for SAP assessors and for MCS installers

m

2 litres litres m

2 litres m

2

Inches

Inches

Inches

Heating flow / return

Solar

Thermal output data

Volume of hot water at given draw-off rate; without reheating

(inlet = 10 °C / outlet = 40 °C / store = 50 °C)

Reheat time (Wh) at given draw-off volume

(inlet = 10 °C / outlet = 40 °C / store = 50 °C) litres mins

DHW Thermal store combination

Daikin Altherma LT

Connection kit (2)

Immersion heater (required)

Daikin Altherma HT

Connection kit

Immersion heater (optional)

1. with immersion heater 2. connection kits include 3WV, sensors and isolation valves

EKSV21P

Vertical

2000x1006x85

35

6

200

2.0 / 1.8

0.784

4.25

0.0072

Solar panel Solar pump station

EKSV26P

Vertical

2000x1300x85

42

6

200

2.6 / 2.36

0.784

4.25

0.0072

EKSRDS1A

pressurised

410x240x130

230 / 50Hz

Grundfos solar 25-65 130

52

6

2

0-120 (160 short term)

1¼” female for Ø 22 clamping ring bolt (x4)

EKSR3PA

332x230x145

230 / 50Hz

2

Plain text

EKHWP300B

300

59

359

1640x615x595

85

1.4

27.9

6

5.8

300

300

N/A

13.2

2.7

8 l/min = 184

12 l/min = 153

With 8kW heat pump

90 litres = 30

140 litres = 45

EKHWP300B

ERLQ004-8

EKDVCPLT3HX

EKBH3S

ERSQ011-16

EKEPHT3H

16 51 35

Stainless Steel 1.4404

1” outer thread

1” female / 1” male

1” internal thread

Solar controller DHW Thermal Store

EKSH26P

Horizontal

1300x2000x85

42

6

200

2.6 / 2.36

0.784

4.25

0.0072

EKSRPS3B

drainback

230x815x142

230 / 50Hz

Grundfos UPS0 15-65 (x2)

120

-

-

-

-

-

-

230 / 50Hz

2

Plain text

EKHWP500B

500

93

593

1640x790x790

85

1.4

29.0

6

6.0

500

500

N/A

18.5

3.8

8 l/min = 364 (1)

12 l/min = 318 (1)

With 16kW heat pump

90 litres = 17

140 litres = 25

EKHWP500B

ERLQ011-16

EKDVCPLT5H

EKBH3S

ERSQ011-16

EKEPHT5H

16 51 35

Price List 2015 109

Daikin solar thermal system

Solar panels, fixings and installation kits (common components)

Description

Solar panel (vertical) – standard

(2000 x 1300 x 85mm), aperture area 2.35m

2

, weight 42kg, water content 1.7 L. Max. 6 bar

Note: Pressurised solar max 3 panels, drainback max 5 panels

Part number

EKSV26P

Trade Price

£404.00

£338.00

Solar panel (vertical) – small

(2000 x 1006 x 85mm), aperture area 1.79m

2

, weight 35kg, water content 1.3 L. Max. 6 bar

Note: Pressurised solar max 3 panels, drainback max 5 panels

EKSV21P

Solar panel (horizontal) – standard

(1300 x 2000 x 85mm), aperture area 2.35m

2 , weight 42kg, water content 2.1 L. Max. 6 bar

Note: For pressurised systems only

EKSH26P

£415.00

Kit to couple 2 solar panels

Mounting profile connector, expansion joints and double clamping blocks

162016-RTX

£35.00

Mounting rail for vertical panels

Consisting of mounting profile rails and solar panel securing ties

Note: Different for standard and small panels

4x Support hooks for high profile tiles

4 double height-adjustable roof ties including fixing material for one solar panel

Note: Was EKSFIXADP

162066

For EKSV21P

(Was 162013)

162067

For EKSV26P

(Was EKSFIXMP130)

162068

For EKSH26P

(Was EKSFIXMP200)

162036-RTX

£24.00

£30.00

£42.00

£69.00

164723

£40.00

4x Support hooks for flat tiles (slate)

4 roof ties for flat roofing, e.g. slate, for one solar panel

Note: Was EKSFIXADS

4x Support hooks for curved roofings

Including fixing material for one solar panel

Note: Was EKSFIXWD

164703-RTX

£50.00

110 Residential, Commercial and Industrial

Daikin solar thermal system

Solar panels, fixings and installation kits (common components)

Description

4x Support hooks for sheet metal roofs

Including fixing material for one solar panel

Note: Was EKSFIXBD

Part number

164704-RTX

Trade Price

£47.00

In-roof installation kit for 2x vertical panels

For two solar panels, covering sheets complete with mounting material.

Minimum roof angle 15°

Note: Different for standard and small panels

In-roof extension kit for 1 additional vertical panel

For one further solar panel, covering sheets complete with mounting material.

Minimum roof angle 15°

Note: Different for standard and small panels

Flat roof kit for 2x vertical panels

Preassembled system for quick and easy assembly, with incremental adjustment of solar panel inclination between 30-60 degrees

Note: For EKSV26P only

162019

For EKSV26P

162017

For EKSV21P

162020

For EKSV26P

162018

For EKSV21P

162058

Flat roof extension kit for 1 additional vertical panel

Preassembled system for quick and easy assembly, with incremental adjustment of solar panel inclination between 30-60 degrees

Note: For EKSV26P only

162059

Flat roof kit for 1 horizontal panel

Preassembled system for quick and easy assembly, with incremental adjustment of solar panel inclination between 30-60 degrees

Note: For EKSH26P only

162060

Flat roof extension kit for 1 additional horizontal panel

Preassembled system for quick and easy assembly, with incremental adjustment of solar panel inclination between 30-60 degrees

Note: For EKSH26P only

162061

Connection cable to disable heat pump

The connection cable is required to connect the solar priority PCB kit to heat pump

Note: Need to order EKRP1HBA with this part

Was EKS164110

Solar priority PCB kit

This enables an interlock between the Daikin solar controller and Altherma heat pumps

Note: Need to order 164110-RTX with this part

164110-RTX

EKRP1HBA

£256.00

£426.00

£199.00

£190.00

£382.00

£152.00

£181.00

£125.00

£11.00

£104.00

Price List 2015 111

Daikin solar thermal system

Solar pressurised accessories

Description

Solar controller

Unit ready to plug in (230V), easy to wire and fit. Wall mounted digital differential temperature control system, return flow and storage tank temperature sensors are included

Note: For use with EKHWSU & EKSOLHW only

Part number

EKSR3PA

Pump station

Consisting of: Pipe connection (diameter 22mm) including pipe compression fittings and support sleeves (5x), flow regulator with 2 x KFE valves, integrated air separator, ball valves with integrated backflow preventor, Grundfos Solar 25-65 pump, safety group with pressure gauge, including insulation and mounting accessories

EKSRDS1A

Trade Price

£191.00

£284.00

Flow sensor for energy metering

Flow sensor for energy monitoring to enable automatic pump speed control to maximise efficiency by measuring the flow volume and flow temperature

Note: Was EKSFLP12A

Hydraulic connection kit (pressurised)

Connection kit for pressurised only, includes connection to solar panel, 2m UV resistant heat insulation for the external area and solar panel temperature sensor

164116

EKSRCP

£75.00

£112.00

Connection pipe for solar panel rows

Connection kit for connecting two rows of collectors one above the other.

Consisting of solar panel mounting material, equipotential bonding clamps, end caps, connecting brackets and 1m thermally insulated piping

Note: Was EKSCONLCP

Antifreeze fluid (glycol, 20L)

20L of pre-mixed solar fluid in a canister, SOL 5F.

Functional range up to -28°C

Note: Was EKSGFL

Thermostatic Mixing Valve

Thermal safety device for DHW outlet with a setting range from 35-60°C

162045

162052-RTX

156015 + 156016

£75.00

£70.00

£65.00 +

£27.00

15m solar pressurised pipe

Pre-insulated stainless steel flexible pipework with sensor cable, order with fittings as shown

162073 + 162075

Up to 3 panels (DN16)

Note: Order connection pack separately

162073 + 162075 was 162021-RTX

162074 + 162076 was 162026-RTX

162074 + 162076

4-5 panels (DN20)

Solar pipe connectors

Connectors to fit 2 pipes together for extension of solar pipe

Note: 162071 was 162027-RTX

162072 was 162028-RTX

162071

Up to 25m (DN16)

162072

Up to 25m (DN20)

Solar expansion vessel

Bracket and flexi hose included for installation

162050

25 litre

162051-RTX

35 litre

Solar connection kit for EKHWSU cylinder for connecting to solar panels

A specially designed kit transfers solar heat into the Daikin Altherma hot water cylinder via an external heat exchanger, which allows the entire content of the cylinder to be heated efficiently with solar heat. Price shown includes EKUHW2WB 2-way valve. Delivered with

EKRP1HBA PCB adaptor

Note: For use with EKHWSU only

EKSOLHW

+

EKUHW2WB

112 Residential, Commercial and Industrial

£240.00 +

£34.00

£350.00 +

£50.00

£24.00

£20.00

£56.00

£144.00

£533.00

Daikin solar thermal system

Solar drainback accessories

Description

Solar controller and pump station

Unit ready to plug in (230V), with digital differential temperature control system, return flow and storage tank temperature sensors and operating pump

Part number

EKSRPS3B

Trade Price

£416.00

Solar connection pipe

Ready to plug in connection pipe between the solar panel and the pump station, consisting of thermally insulated flow and return lines with integrated sensor cable.

Available in 15 and 20m lengths

Note: 164732 was EKSCON15

164733 was EKSCON20

164732

15m length

164733

20m length

Solar connection pipe extension

Ready to plug in, including fitting materials and connection fittings.

Available in 2.5, 5 and 10m lengths

Note: 164261-RTX was EKSCONX25

164262-RTX was EKSCONX50

164263 was EKSCONX100

Maximum possible length of the connection pipe

Number of solar panels Max. length

4

5

2

3

45m

30m

17m

15m

Solar flow pipe extension

UV resistant thermally insulated, length L = 8m, including cable connection fitting for the solar panel sensor line

Note: Was EKSCONXV80

164261-RTX

2.5m

164262-RTX

5m

164263

10m

164264

Copper pipe connection kit

Connection kit when connecting onto copper pipe (if Daikin drainback pipe is not used).

Consisting of 2m flow and return pipes, push-fit coupling onto 15mm and 18mm copper pipe

164232

Solar panel row connection kit

Connection kit for connecting two rows of collectors one above the other.

Consisting of solar panel mounting material, equipotential bonding clamps, end caps, connecting brackets and 1m thermally insulated piping

Note: Was EKSCONRVP

Hydraulic connection kit (on-roof)

Connection kit for drainback (on-roof), includes connection to solar panel, pitched roof flashing, 2m UV resistant insulation and solar panel temperature sensor

Available in Anthracite or Brick red

Hydraulic connection kit (in-roof) NEW!

Connection kit for drainback (in-roof), includes connection to solar panel and solar panel temperature sensor

162035-RTX

EKSRCRP

Brick red

EKSRCAP

Anthracite

162037-RTX

£94.00

£112.00

£59.00

£67.00

£88.00

£74.00

£54.00

£65.00

£154.00

£154.00

£100.00

Price List 2015 113

Daikin solar thermal system

Solar drainback accessories

(Continued)

Description

Hydraulic connection kit (flat roof) NEW!

Connection kit for drainback (flat roof), includes connection to solar panel, flat roof penetration, 8.5m UV resistant insulation and solar panel temperature sensor

Part number

162038-RTX

Gravity break set

Avoids thermal heat loss from thermal store due to thermo-siphon effect.

Advised when piping from heat exchanger is not making a down ward bend at the tank

165070

Solar flow setter

Flow regulating valve with flow indicator (2-16 l/min). For balancing solar flow in cascade thermal store installations

Note: For use only with EKHWP* only

164102-RTX

Secondary circulation kit

Connection kit for secondary hot water connections

Note: For use with EKHWP* only

165113

Trade Price

£194.00

£8.00

£53.00

£79.00

Daikin solar thermal system

Thermal store for Daikin Altherma High and Low Temperature

This is a hot water thermal storage tank and provides instantaneous hot water.

The tank serves as a heat storage medium. It can be heated by both Daikin Altherma heat pumps and solar energy.

Description

Thermal store (EKHWP***B) combination with Daikin Altherma High Temperature

EKHWP300B with connection kit for ERSQ011-016

Part number

EKHWP300B + EKEPHT3H

Trade Price

£1,159.00

EKHWP500B + EKEPHT5H

£1,409.00

EKHWP500B with connection kit for ERSQ011-016

Thermal store (EKHWP***B) combination with Daikin Altherma Low Temperature

EKHWP300B with connection kit for ERLQ004-008

(Heating / cooling) and 3kW immersion heater

EKHWP500B with connection kit for ERLQ011-016

(Heating only) and 3kW immersion heater

Connection elbow enables easy filling and draining of the storage tank

EKHWP300B + EKDVCPLT3HX

+ EKBH3S

EKHWP500B + EKDVCPLT5H

+ EKBH3S

165210

£1,315.00

£1,595.00

£21.00

Fill and drain connection 165215

£23.00

Note: It is recommended that 165210 and 165215 are ordered with every thermal store

114 Residential, Commercial and Industrial

Daikin solar thermal system

Solar standalone accessories

The standalone pressurised solar system is designed for use with auxiliary gas boiler and twin coil cylinder.

Available in predefined on-roof and in-roof packs (see page 121)

Description

Solar panel (vertical) – small

(2006 x 1006 x 85mm), aperture area 1.79m

2 , weight 35kg, water content 1.3 L. Max. 6 bar

Part number

EKSV21P

Trade Price

£338.00

Mounting rail for small panels

Consisting of mounting profile rails and securing ties

Note: Was 162013

4x Support hooks for high profile tiles

4 double height-adjustable roof ties including fixing material for one solar panel

Note: Was EKSFIXADP

162066

162036-RTX

4x Support hooks for flat tiles (slate)

4 roof ties for flat roofing, e.g. slate, for one solar panel

Note: Was EKSFIXADS

164723

Pump station

Consisting of: Pipe connection (diameter 22mm) including pipe compression fittings and support sleeves (5x), flow regulator with 2 x KFE valves, integrated air seperator, ball valves with integrated backflow preventor, Grundfos Solar 25-65 pump, safety group with pressure gauge, including insulation and mounting accessories

EKSRDS1A

£24.00

£69.00

£40.00

£284.00

Hydraulic connection kit (pressurised)

Connection kit for pressurised only, includes connection to solar panel,

2m UV resistant heat insulation for the external area and solar panel temperature sensor

EKSRCP

£112.00

Solar controller for standalone solar

Wall mounted, small and compact. Easy to use solar controller with back-lit graphical illuminated display. Auxiliary heat source timer and pump speed control

Note: To control auxiliary gas boiler only

UK.SOLCTRBS4

Twin coil solar cylinder

Unvented stainless steel cylinder. Designed for gas boiler auxiliary heating and solar hot water connections. Delivered with full G3 compliance kit including

2-port motorised valve (except expansion vessel - field supply)

FKU-HWS200TC

200L

FKU-HWS250TC

250L

FKU-HWS300TC

300L

Note: Further standalone solar components are available to complete the standalone system (see pages 110-112)

* Special offer for limited period. New discounted prices

£191.00

£500.00*

Sell out price

£525.00*

£570.00*

Price List 2015 115

Selecting the right solar system

Daikin have a full range of solar thermal solutions including Drainback and Pressurised solutions to suit many installation requirements.

Solar systems are available to work with heat pumps or with boilers and offer enhanced DHW energy savings.

Use the table below to help select the right kind of solar system for your Daikin heat pump or your existing boiler.

Solar system Drainback Pressurised

Auxiliary heat source

Tank

HT or LT Heat Pump

Thermal Store

(EKHWP)

Vertical

2.6m

2

LT Heat Pump Boiler

Single coil + solar kit

(EHHWSU + EKUHW2WB)

Twin coil

(FKU)

Vertical

2.6m

2

Horizontal

2.6m

2

Vertical

2.0m

2

Panel orientation and size

On-roof

In-roof

Flat roof

3

(page 118)

3

(page 118)

3

(page 118)

3

(page 119)

3

(page 120)

3

(page 120)

3

(page 119)

3

(page 121)

7

3

(page 121)

3

(page 120)

7

116 Residential, Commercial and Industrial

Selecting the right solar pack

Daikin offer solar systems in ready to order packs with all the key components include.

After deciding between drainback or pressurised solar, use this table to select the right solar pack for your project.

Daikin solar thermal system

Solar packs – quick selection table

System type

Drainback

(For Daikin

Altherma HT and LT)

Orientation

Vertical

Fixing type

On-roof

Tile

Profiled tile

Slate/flat tile

Roof cowl

Anthracite

Anthracite

1 panel pack

UK.SP1VPDBA

2 panel pack

UK.SP2VPDBA

3 panel pack

UK.SP3VPDBA

4 panel pack

UK.SP4VPDBA

5 panel pack

UK.SP5VPDBA

UK.SP1VSDBA

UK.SP2VSDBA

UK.SP3VSDBA

UK.SP4VSDBA

UK.SP5VSDBA

Profiled tile Red

Slate/flat tile Red

In-roof

Flat-roof -

Profiled/slate/ flat tile

-

-

Pressurised

(For Daikin

Altherma LT)

Vertical On-roof Profiled tile -

Slate/flat tile -

In-roof

Flat-roof -

Profiled/slate/ flat tile

-

-

Horizontal On-roof Profiled tile -

Slate/flat tile -

UK.SP1VPDBR

UK.SP2VPDBR

UK.SP3VPDBR

UK.SP4VPDBR

UK.SP5VPDBR

UK.SP1VSDBR

UK.SP2VSDBR

UK.SP3VSDBR

UK.SP4VSDBR

UK.SP5VSDBR

UK.SP2VIDBA

UK.SP3VIDBA

UK.SP4VIDBA

UK.SP5VIDBA

UK.SP1VADBA

UK.SP2VADBA

UK.SP3VADBA

UK.SP4VADBA

UK.SP5VADBA

UK.SP1VPP

UK.SP2VPP

UK.SP3VPP

UK.SP1VSP

UK.SP2VSP

UK.SP3VSP

UK.SP2VIP

UK.SP3VIP

UK.SP1VAP

UK.SP2VAP

UK.SP3VAP

UK.SP1HPP

UK.SP2HPP

UK.SP3HPP

UK.SP1HSP

UK.SP2HSP

UK.SP3HSP

-

Pressurised

(Standalone)

Vertical

Flat-roof -

On-roof Profiled tile -

-

In-roof

Slate/flat tile -

Profiled/slate/ flat tile

-

UK.SP1HAP

UK.SP2HAP

UK.SP3HAP

UK.V21PP1

UK.V21PP2

UK.V21PP3

UK.V21SP1

UK.V21SP2

UK.V21SP3

UK.V21IP2

UK.V21IP3

-

Price List 2015 117

Daikin solar thermal system

Solar packs – drainback system for Daikin Altherma

High Temperature and Low Temperature

Vertical on-roof profiled tile pack

Vertical pack order reference

This pack contains:

Vertical flat plate collector

Roof brackets for concrete / profiled x 4

Mounting rail for panel

Hydraulic connection kit (on-roof) including cowl in either:

Solar controller & pump station*

Coupling kit for multiple panels

Connection cable to disable heat pump

Pack price

Part number

Anthracite / Red

EKSV26P

162036-RTX

162067

EKSRCAP / EKSRCRP

EKSRPS3B

162016-RTX

164110-RTX

1 panel pack

UK.SP1VPDBA/R

Quantity

1

1

1

1

1

0

1

£1,084.00

2 panel pack

UK.SP2VPDBA/R

Quantity

2

2

2

1

1

1

1

£1,622.00

3 panel pack

UK.SP3VPDBA/R

Quantity

3

3

3

1

1

2

1

£2,160.00

4 panel pack

UK.SP4VPDBA/R

Quantity

4

4

4

1

1

3

1

£2,698.00

5 panel pack

UK.SP5VPDBA/R

Quantity

5

5

5

1

1

4

1

£3,236.00

Vertical on-roof slate tile pack

Vertical pack order reference

This pack contains:

Vertical flat plate collector

Roof brackets for slate / flat tiles x 4

Mounting rail for panel

Hydraulic connection kit (on-roof) including cowl in either:

Solar controller & pump station*

Coupling kit for multiple panels

Connection cable to disable heat pump

Pack price

Part number

Anthracite / Red

EKSV26P

164723

162067

EKSRCAP / EKSRCRP

EKSRPS3B

162016-RTX

164110-RTX

1 panel pack

UK.SP1VSDBA/R

Quantity

1

1

1

1

1

0

1

£1,055.00

2 panel pack

UK.SP2VSDBA/R

Quantity

2

1

2

2

1

1

1

£1,564.00

3 panel pack

UK.SP3VSDBA/R

Quantity

3

1

3

3

1

2

1

£2,073.00

4 panel pack

UK.SP4VSDBA/R

Quantity

4

1

4

4

1

3

1

£2,582.00

5 panel pack

UK.SP5VSDBA/R

Quantity

5

1

5

5

1

4

1

£3,091.00

Part number Vertical in-roof pack

Vertical pack order reference

This pack contains:

Vertical flat plate collector

Mounting rail for panel

Hydraulic connection kit (in-roof)

Solar controller & pump station*

Coupling kit for multiple panels

In-roof kit for 2x vertical panels

In-roof extension kit for 1x panel

Connection cable to disable heat pump

Pack price

Vertical flat roof pack

Vertical pack order reference

This pack contains:

Vertical flat plate collector

Mounting rail for panel

Hydraulic connection kit (flat roof) including flat roof penetration

Solar controller & pump station*

Coupling kit for multiple panels

Solar flat roof kit for 2xV26P

Solar flat roof kit for additional V26P

Connection cable to disable heat pump

Pack price

EKSV26P

162067

162037-RTX

EKSRPS3B

162016-RTX

162019

162020

164110-RTX

Part number

EKSV26P

162067

162038-RTX

EKSRPS3B

162016-RTX

162058

162059

164110-RTX

1 panel pack

-

Quantity

-

-

-

-

-

-

-

-

-

2 panel pack

UK.SP2VIDBA/R

Quantity

2

2

1

1

1

1

0

1

£1,686.00

3 panel pack

UK.SP3VIDBA/R

Quantity

3

3

1

1

2

1

1

1

£2,354.00

4 panel pack

UK.SP4VIDBA/R

Quantity

4

4

1

1

3

1

2

1

£3,022.00

5 panel pack

UK.SP5VIDBA/R

Quantity

5

5

1

1

4

1

3

1

£3,690.00

1 panel pack

UK.SP1VADBA/R

Quantity

1

1

1

1

0

1

0

1

£1,437.00

2 panel pack

UK.SP2VADBA/R

Quantity

2

2

1

1

0

1

1

1

£1,906.00

3 panel pack

UK.SP3VADBA/R

Quantity

3

3

1

1

1

1

2

1

£2,527.00

4 panel pack

UK.SP4VADBA/R

Quantity

4

4

1

1

2

1

3

1

£3,148.00

5 panel pack

UK.SP5VADBA/R

Quantity

5

5

1

1

3

1

4

1

£3,769.00

Important:

When installing an integrated Daikin Altherma HT and Daikin drainback solar system, the following accessories need to be ordered separately:

EKHWP – Thermal store

EKRP1HBA – Option PCB for use with Hydrobox for alarm monitoring (Solar priority PCB)

EKSCON*** – Solar connection pipe

* When installing an integrated ROTEX Gas Compact Unit and Daikin drainback solar system, order 164125 instead of EKSRPS3B

118 Residential, Commercial and Industrial

Daikin solar thermal system

Solar packs – pressurised system for Daikin Altherma Low Temperature

Vertical on-roof profiled tile pack

Vertical pack order reference

This pack contains:

Vertical flat plate collector

Roof brackets for concrete / profiled tiles x 4

Mounting rail for panel

Hydraulic connection kit

Solar controller

Solar pump station

Flow sensor

Solar fluid (20 litres)

Coupling kit for multiple panels

Solar expansion vessel (25 litres)

Connection cable to disable heat pump

Pack price

Vertical on-roof slate / flat tile pack

Vertical pack order reference

This pack contains:

Vertical flat plate collector

Roof brackets for slate / flat tiles x 4

Mounting rail for panel

Hydraulic connection kit

Solar controller

Solar pump station

Flow sensor

Solar fluid (20 litres)

Coupling kit for multiple panels

Solar expansion vessel (25 litres)

Connection cable to disable heat pump

Pack price

Horizontal on-roof profiled tile pack

Horizontal pack order reference

This pack contains:

Horizontal flat plate collector

Roof brackets for concrete / profiled tiles x 4

Mounting rail for panel

Hydraulic connection kit

Solar controller

Solar pump station

Flow sensor

Solar fluid (20 litres)

Coupling kit for multiple panels

Solar expansion vessel (25 litres)

Connection cable to disable heat pump

Pack price

Horizontal on-roof slate / flat tile pack

Horizontal pack order reference

This pack contains:

Horizontal flat plate collector

Roof brackets for slate/flat tiles x 4

Mounting rail for panel

Hydraulic connection kit

Solar controller

Solar pump station

Flow sensor

Solar fluid (20 litres)

Coupling kit for multiple panels

Solar expansion vessel (25 litres)

Connection cable to disable heat pump

Pack price

Part number

EKSV26P

162036-RTX

162067

EKSRCP

EKSR3PA

EKSRDS1A

164116

162052-RTX

162016-RTX

162050

164110-RTX

Part number

EKSV26P

164723

162067

EKSRCP

EKSR3PA

EKSRDS1A

164116

162052-RTX

162016-RTX

162050

164110-RTX

Part number

EKSH26P

162036-RTX

162068

EKSRCP

EKSR3PA

EKSRDS1A

164116

162052-RTX

162016-RTX

162050

164110-RTX

Part number

EKSH26P

164723

162068

EKSRCP

EKSR3PA

EKSRDS1A

164116

162052-RTX

162016-RTX

162050

164110-RTX

1 panel pack

UK.SP1HPP

Quantity

1

1

0

1

1

1

1

1

1

1

1

£1,325.00

1 panel pack

UK.SP1VSP

Quantity

1

1

0

1

1

1

1

1

1

1

1

£1,273.00

1 panel pack

UK.SP1HSP

Quantity

1

1

1

1

1

1

1

1

0

1

1

£1,296.00

1 panel pack

UK.SP1VPP

Quantity

1

1

1

1

1

1

1

1

1

1

0

£1,302.00

2 panel pack

UK.SP2HPP

Quantity

2

1

1

1

1

1

1

2

2

1

1

£1,886.00

2 panel pack

UK.SP2VSP

Quantity

2

2

1

1

1

1

1

1

2

1

1

£1,782.00

2 panel pack

UK.SP2HSP

Quantity

2

2

2

1

1

1

1

1

1

1

1

£1,828.00

2 panel pack

UK.SP2VPP

Quantity

2

2

2

1

1

1

1

1

1

1

1

£1,840.00

Important:

Packs detailed above are for pressurised solar thermal systems for Daikin Altherma Low Temperature.

When installing an integrated Daikin Altherma heat pump and pressurised Daikin solar thermal system, the following accessories need to be ordered separately:

EKHWSU – Domestic hot water cylinder

EKSOLHW – Solar kit for EKHWSU tank

1620** – Solar pressurised pipe and connectors

3 panel pack

UK.SP3HPP

Quantity

3

1

2

1

1

1

1

3

3

1

1

£2,447.00

3 panel pack

UK.SP3VSP

Quantity

3

3

2

1

1

1

1

1

3

1

1

£2,291.00

3 panel pack

UK.SP3HSP

Quantity

3

3

3

1

1

1

1

1

2

1

1

£2,360.00

3 panel pack

UK.SP3VPP

Quantity

3

3

3

1

1

1

1

1

1

1

2

£2,378.00

Price List 2015 119

Daikin solar thermal system

Solar packs – pressurised system for Daikin Altherma Low Temperature

(Continued)

Vertical in-roof pack

Vertical pack order reference

This pack contains:

Vertical flat plate collector

Mounting rail for panel

Hydraulic connection kit

Solar controller

Solar pump station

Flow sensor

Solar fluid (20 Litres)

Coupling kit for multiple panels

In roof kit for 2 x V26P

In roof extension kit for additional V26P

Solar expansion vessel (25 litres)

Connection cable to disable heat pump

Pack price

Part number

EKSV26P

162067

EKSRCP

EKSR3PA

EKSRDS1A

164116

162052-RTX

162016-RTX

162019

162020

162050

164110-RTX

2 panel pack

UK.SP2VIP

Quantity

2

2

1

0

1

1

1

1

1

1

1

1

£1,958.00

3 panel pack

UK.SP3VIP

Quantity

3

3

1

1

1

2

1

1

1

1

1

1

£2,626.00

Vertical flat roof pack

Vertical pack order reference

This pack contains:

Vertical flat plate collector

Mounting rail for panel

Hydraulic connection kit

Solar controller

Solar pump station

Flow sensor

Solar fluid (20 Litres)

Coupling kit for multiple panels

Solar flat roof kit for 2xV26P

Solar flat roof kit for additional V26P

Solar expansion vessel (25 litres)

Connection cable to disable heat pump

Pack price

Horizontal flat roof pack

Horizontal pack order reference

This pack contains:

Horizontal flat plate collector

Mounting rail for panel

Hydraulic connection kit

Solar controller

Solar pump station

Flow sensor

Solar fluid (20 Litres)

Coupling kit for multiple panels

Solar flat roof kit for H26P

Solar flat roof kit for additional H26P

Solar expansion vessel (25 litres)

Connection cable to disable heat pump

Pack price

Part number

EKSH26P

162068

EKSRCP

EKSR3PA

EKSRDS1A

164116

162052-RTX

162016-RTX

162060

162061

162050

164110-RTX

Part number

EKSV26P

162067

EKSRCP

EKSR3PA

EKSRDS1A

164116

162052-RTX

162016-RTX

162058

162059

162050

164110-RTX

1 panel pack*

UK.SP1VAP

Quantity

1

1

1

1

1

0

1

1

1

1

1

0

£1,615.00

1 panel pack

UK.SP1HAP

Quantity

1

0

1

1

1

1

1

1

1

0

1

1

£1,437.00

2 panel pack

UK.SP2VAP

Quantity

2

2

1

1

1

1

1

1

1

1

1

0

£2,084.00

2 panel pack

UK.SP2HAP

Quantity

1

1

1

1

1

1

2

2

1

1

1

1

£2,054.00

3 panel pack

UK.SP3VAP

Quantity

3

3

1

1

1

2

1

1

1

1

1

1

£2,705.00

3 panel pack

UK.SP3HAP

Quantity

1

2

1

1

1

1

3

3

1

2

1

1

£2,671.00

* Important:

When ordering the vertical flat roof pack, please be aware the solar flat roof kit comes for 2 vertical panels, thus some wastage will occur (the wastage is not enough to be used for another panel).

Important:

Packs detailed above are for pressurised solar thermal systems for Daikin Altherma Low Temperature.

When installing an integrated Daikin Altherma heat pump and pressurised Daikin solar thermal system, the following accessories need to be ordered separately:

EKHWSU – Domestic hot water cylinder

EKSOLHW – Solar kit for EKHWSU tank

1620** – Solar pressurised pipe and connectors

120 Residential, Commercial and Industrial

Daikin solar thermal system

Solar packs – standalone pressurised system for use with auxiliary gas boiler

Vertical on-roof profiled tile pack

Vertical pack order reference

This pack contains:

Vertical flat plate collector (small panel)

Roof brackets for concrete / profiled tiles x 4

Mounting rail for panel

Hydraulic connection kit

Solar controller (for auxiliary gas boiler)

Solar pump station

Solar fluid (20 litres)

Coupling kit for multiple panels

Solar expansion vessel (25 litres)

Pack price

Part number

EKSV21P

162036-RTX

162066

EKSRCP

UK.SOLCTRBS4

EKSRDS1A

162052-RTX

162016-RTX

162050

1 panel pack

UK.V21PP1

Quantity

1

1

1

1

1

1

1

0

1

£1,144.00

2 panel pack

UK.V21PP2

Quantity

2

2

2

1

1

1

1

1

1

£1,610.00

Vertical on-roof slate / flat tile pack

Vertical pack order reference

This pack contains:

Vertical flat plate collector (small panel)

Roof brackets for slate / flat tiles x 4

Mounting rail for panel

Hydraulic connection kit

Solar controller (for auxiliary gas boiler)

Solar pump station

Solar fluid (20 litres)

Coupling kit for multiple panels

Solar expansion vessel (25 litres)

Pack price

Part number

EKSV21P

164723

162066

EKSRCP

UK.SOLCTRBS4

EKSRDS1A

162052-RTX

162016-RTX

162050

1 panel pack

UK.V21SP1

Quantity

1

1

1

1

1

0

1

1

1

£1,115.00

2 panel pack

UK.V21SP2

Quantity

2

2

2

1

1

1

1

1

1

£1,552.00

Vertical in-roof pack

Vertical pack order reference

This pack contains:

Vertical flat plate collector (small panel)

Mounting rail for panel

Hydraulic connection kit

Solar controller (for auxiliary gas boiler)

Solar pump station

Solar fluid (20 litres)

Coupling kit for multiple panels

Solar expansion vessel (25 litres)

In roof kit for 2 x V21P

In roof extension kit for additional V21P

Pack price

Part number

EKSV21P

162066

EKSRCP

UK.SOLCTRBS4

EKSRDS1A

162052-RTX

162016-RTX

162050

162017

162018

2 panel pack

UK.V21IP2

Quantity

2

2

1

1

1

1

1

1

1

0

£1,898.00

3 panel pack

UK.V21IP3

Quantity

3

3

1

1

2

1

1

1

1

1

£2,485.00

3 panel pack

UK.V21PP3

Quantity

3

3

3

1

1

1

1

2

1

£2,076.00

3 panel pack

UK.V21SP3

Quantity

3

3

3

1

1

2

1

1

1

£1,989.00

Important:

Packs detailed above are not designed to be used with Daikin Altherma heat pumps.

The above packs are designed to be used with an auxiliary gas boiler and twin coil cylinder.

To complete the Daikin standalone pressurised solar system, please order twin coil cylinder (FKU-HWS***TC).

Price List 2015 121

Underfloor heating

ROTEX underfloor heating system is designed to work seamlessly with the Daikin Altherma range to provide high heat pump efficiency and low surface temperatures for the most comfortable room climate.

When partnered with heat pumps, UFH with low flow temperatures helps to achieve high heat pump efficiencies and even higher running cost savings.

> Energy saving and highly versatile, can be used with condensing boilers, heat pumps and solar systems

> Simple installation with easy to lay components

> System plates with excellent heat insulation properties and sound insulation properties

> Additional energy benefits recognised in SAP and MCS

> Rotex Monopex is ideal for low temperature systems such as heat pumps and is available in a variety of pipe sizes

> Rotex System 70 is ideal for mixed UFH and radiator systems and commercial heating systems with primary flow temperatures 55 - 70°C

For information

on Daikin’s underfloor heating design process go to page 125.

122 Residential, Commercial and Industrial

Underfloor heating system

Underfloor heating plates

Protect system plates: Styrofoam nap-plates with a protective layer of deep-drawn polystyrene.

Overlapping connection for easy fixing. Installation dimensions 122 x 120cm. Suitable for heating pipes with Ø 14 and 17mm. Rectangular or diagonal heating pipe installation.

Spacing: Right-angled pipes: 75, 150, 225, 300mm. Diagonal pipes: 55, 110, 165, 220, 275, 330mm.

Note: See page 127 for clip rail and staple systems.

Description Quantity per pack Part number

Protect-Integral 33-3

Height 48mm.

Heat conduction resistance: 0.75 m2K/W.

Integrated heat and sound insulation

Installation against heated rooms

8

(11.71m

2

)

171040

Protect-Integral 33-3 HKV

Reduced number of naps for use in vicinity of heating manifolds and door passages

2

(2.88m

2 )

171043

Trade Price

£104.00

£21.00

Protect 10

Height 28mm.

Heat conduction resistance: 0.29 m2K/W.

For constructions with increased load and several insulation layers

Protect 10 HKV

Reduced number of naps for use in vicinity of heating manifolds and door passages

Protect Mini

Height 24mm.

Heat conduction resistance: 0.17 m2K/W.

Only suitable for heating pipes 13mm and 14mm.

For use in constructions with low construction height

13

(19.03m

2 )

3

(4.32m

2 )

10

(14.64m

2

)

171041

171044

171037

£141.00

£33.00

£91.00

Protect Mini Solo

Height 17mm.

Deep-drawn polystyrene plate but without heat and sound insulation.

For use in constructions with low construction height

10

(14.64m

2 )

171038

£47.00

Styrofoam nap-plate: With integrated connection technique for the system plates. Installation dimensions: 120 x 60cm.

Suitable for heating pipe with Ø 14 and 17mm. Rectangular heating pipe installation. Spacing: 75, 150, 225, 300mm.

Mono 15

Height 38mm.

Heat conduction resistance: 0.43m²K/W

Styrofoam system plate without noise insulation.

For use in constructions with reduced construction height

20

(14.4m

2 )

Compact 45

Height 67mm.

Heat conduction resistance: 1.28 m2K/W.

Styrofoam system plate with increased heat insulation.

Installation in constructions against unheated rooms and earth

Isodur plate

Height 55mm

Heat conduction resistance: 0.85m²K/W.

Suitable for DUO 25 heating pipe

Spacing: 200, 300, 400mm.

For industrial buildings and large areas

11

(7.92m

2 )

14

(10.8m

2 )

Dry system Secco: For dry construction, in profiled, galvanised sheet steel, suitable for Mono, Basic and Compact plate.

Package contents: 120 x 37cm, Qty 8 / 40 x 37cm, Qty 6

Aluminium plate for Secco system

1

(5.35m

2 )

171010

171017

171013

£110.00

£90.00

£80.00

171112

Monopex 14AL

171113

DUO 17

£120.00

£131.00

Price List 2015 123

Underfloor heating system

Heat emission plate

Dual channel aluminium spreader plates for timber suspended or battened floor installations.

For joists at 400mm centres. Plate dimensions 1000x390mm

Description

Spreader plates

For Ø 17mm pipe

Length

10

(3.9m

2

)

Part number

171141

Underfloor heating system

Underfloor heating pipes

Monopex heating pipes: Thick-walled, linked basic PE-X pipe with oxygen-tight barrier for Monopex low temperature underfloor heating systems.

Description Length

Monopex 14 PE-X 14 x 2 OD

For Monopex underfloor heating system

120m

Part number

170008

240m 170009

Monopex 14 ALU thick-walled PE-X

14 x 2 Aluminium coating and PE external layer.

For Monopex underfloor heating systems

Monopex 17 PE-X 17 x 2 OD

For Monopex underfloor heating system

120m

240m

120m

240m

600m

Monopex 20 PE-X 20 x 2 OD

For Monopex underfloor heating system

120m

240m

400m

Protective pipe

Black corrugated pipe made of plastic as additional insulation in the area of the manifold and expansion joints

25m

25m

75m

DUO heating pipes: Thick-walled linked PE-X basic pipe, with oxygen-tight barrier, and additional highly flexible PE ribbed pipe.

For underfloor heating systems operated in direct combination with other heating surfaces, e.g. radiators.

120m DUO 17 PE-X 17/12 x 2 OD pipe

For system 70 underfloor heating

& heating radiator connection

Outer pipe Ø 17mm

Inner pipe 12 x 2mm

240m

DUO 17 ALU PE-X 17/12 x 2

With aluminium coating and PE external layer.

For system 70 radiator connection and underfloor heating

Outer pipe Ø 17mm

Inner pipe 12 x 2mm

120m

240m

DUO 25 PE-X 25/18 x 2 OD

For system 70 industrial underfloor heating

200m

170604

170605

170029

170028

170062

170030

170109

170108

170053

Ø 19/25mm

170098

Ø 16/21mm

170001

Ø 23/28mm

170068

170086

170601

170602

170050

124 Residential, Commercial and Industrial

Trade Price

£43.00

Trade Price

£128.00

£255.00

£163.00

£325.00

£540.00

£15.00

£181.00

£360.00

£142.00

£283.00

£705.00

£12.00

£47.00

£199.00

£398.00

£229.00

£457.00

£435.00

Underfloor heating system

Manifolds

RMX manifold: RMX heating circuit manifold, for underfloor heating systems and radiators.

Suitable for the smallest fitting heights. Buy clamping ring sets separately to suit pipe.

Description

Manifold RMX 2-port

Manifold RMX 3-port

Manifold RMX 4-port

Manifold RMX 5-port

Manifold RMX 6-port

Manifold RMX 7-port

Manifold RMX 8-port

Manifold RMX 9-port

Manifold RMX 10-port

Manifold RMX 11-port

Manifold RMX 12-port

HKV heating circuit manifold, suitable for underfloor heating and radiators, with fast mounting system

Manifold HKV 2-port

Manifold HKV 3-port

Manifold HKV 4-port

Manifold HKV 5-port

Manifold HKV 6-port

Manifold HKV 7-port

Manifold HKV 8-port

Manifold HKV 9-port

Manifold HKV 10-port

Manifold HKV 11-port

Manifold HKV 12-port

Manifold HKV 13-port

Manifold HKV 14-port

Kombi box

Subdivision for distribution room-by-room and controller for max. 2 underfloor heating circuits with system 70 for DUO 17 heating pipe and optionally with a radiator complete in UP case incl. cover plates, without clamping ring set and actuator

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

Quantity per pack

1

1

172502

172503

172504

172505

172506

172507

172508

172509

172510

172511

172512

172513

172514

172415

Part number

172702

172703

172704

172705

172706

172707

172708

172709

172710

172711

172712

£72.00

£87.00

£103.00

£116.00

£137.00

£147.00

£162.00

£176.00

£192.00

£206.00

£223.00

£237.00

£291.00

£95.00

Trade Price

£106.00

£124.00

£146.00

£167.00

£189.00

£211.00

£232.00

£254.00

£276.00

£296.00

£319.00

Underfloor heating (UFH) design process

To prepare an accurate bill of materials and quotation for your underfloor heating project, we need to carry out a detailed UFH design. This will take account of parameters including room heat losses, water flow temperature, floor construction, floor coverings and preferred manifold positions.

If you require an UFH design, please contact your sales representative or your local branch for assistance. To enable us to carry out the UFH design, you will need to submit:

> Autocad drawings – floor plans and elevations

> Completed Daikin UFH design request form

(available from your local branch)

Please allow up to 20 working days from submitting your drawings to receiving your quotation.

Once you have placed an order for the UFH materials, we will send you the UFH design for your approval prior to shipping the materials.

Price List 2015 125

Underfloor heating system

Manifold accessories

Description

RMX actutator (230V)

Actuator for RMX manifold and kombi box

Quantity per pack

1

Part number

175145

Trade Price

£18.00

175110

£21.00

HKV actuator (230V)

Actuator for HKV manifold and kombi box

1

Clamping ring set on RMX heating circuit manifold for flow and return per heating circuit

RMX connection set DUO17

RMX connection set Monopex 14

RMX connection set Monopex 17

RMX connection set DUO25

RMX connection set Monopex 20

RMX manifold isolating valves 1”

Coupling nipple (3/4”) for combination with 1703** clamping ring sets

Connection nipple (3/4” PEX x 1/2” male) for combination with 1703** clamping ring sets

Clamping ring set on HKV heating circuit manifold for flow and return, per heating circuit

HKV connection set DUO17

HKV connection set Monopex 14

HKV connection set Monopex 17

HKV connection set DUO25

HKV connection set Monopex 20

Connection kit for HKV2 to HKV14

Contains 2 x isolating valves (1”),

2 x connection pieces,

2 x filling and draining valves and

2 x temperature gauges

2

2

2

1

2

2

2

2

2

2

2

2

2

2

Manifold cabinet up to 7-port

Manifold cabinet up to 10-port

Manifold cabinet up to 14-port

126 Residential, Commercial and Industrial

1

1

1

170312

170314

170317

170318

170320

175514

177227

177327

177012

177014

177017

177018

177020

175510

£8.00

£8.00

£7.00

£7.00

£7.00

£21.00

£8.00

£6.00

£7.00

£7.00

£7.00

£7.00

£8.00

£68.00

174110

174115

174120

£126.00

£139.00

£159.00

Underfloor heating system

Insulating strips and installation accessories

Description

Tacker gun

Tacker gun for 60mm pipe staples.

The tacker gun can be used to secure pipe directly to floor insulation

Quantity per pack

1

Part number

171134

Trade Price

£200.00

Pipe staples

60mm pipe staples for use with tacker gun (171134) and high density insulation with DPM

300

Clip rail

1m pieces, pipe centres 50mm

Clip rail nail KN06

100m

100 pieces

Edging strip

For cement or anhydrite screed.

PE foam with welded foil, height 150mm, 8mm thick

25m

Edging strip

For free-flowing screed PE foam with welded foil, and additional sealing cord.

Height 150mm, 10mm thick

25m

Combined pipe cutters and stripping pliers RAZ1

1

171137

171224

171127

171101

171126

171110

171006

Pipe decoiler RAW 240 for <240m

1

Pipe clips

50

Pipe bend

This is recommended to facilitate the bend of the pipe up-to the manifold

10

£30.00

171117

For Ø 17-20mm

171125

For Ø 25mm

171142

For Ø 14-18mm

171143

For Ø 20-22mm

£6.00

£9.00

£10.00

£13.00

Price List 2015 127

£35.00

£271.00

£27.00

£16.00

£53.00

£525.00

Underfloor heating system

Underfloor heating room controls

Basic range

Note: Cannot be combined with advanced range (see page 129)

Description

RTR5 control

Electronic room temperature control (230V)

Quantity per pack

1

Part number

175117

Trade Price

£21.00

175125

£30.00

RTK control

Room temperature control with heating/cooling function

1

FRT wireless control

Wireless room temperature control

Single FRT wireless receiver

Receiver FEM1 for 1x FRT

Multiple FRT wireless receiver

Receiver FEM4 for 4x FRT

1

1

1

175120

175121

175122

£77.00

£86.00

£152.00

Underfloor heating system

Wiring centres and accessories

Basic range

Note: Cannot be combined with advanced range (see page 129)

Description

Wiring box for 14x SAT

Wiring box 6xRTR and max 14xSAT

Quantity per pack

1

Part number

175131

175132

Wiring box extension for 4x SAT

Wiring box extension for 175131.

Additional 2xRTR and Max 4x SAT

1

Pump module for wiring box

Provides on/off signal to the heat source

Note: Can only be combined with wiring box 175131.

One required per UFH manifold

1

128 Residential, Commercial and Industrial

175134

Trade Price

£62.00

£26.00

£62.00

Underfloor heating system

Underfloor heating room controls

Advanced range

Modern aesthetics, easy to install and greater user comfort

Note: Cannot be combined with basic range (see page 128)

Description

Room thermostat (wired) NEW!

- Electronic room temperature control (5V)

- Adjustment range 5-26C

- Display of heating and cooling mode (red and blue LED)

Quantity per pack

1

Part number

175139

175142

Room thermostat (RF) NEW!

- Electronic room temperature control

- Adjustment range 5-26C

- Solar powered (no batteries required)

- Allow 24 hours to charge before commissioning

1

Trade Price

£27.00

£128.00

Underfloor heating system

Wiring centres and accessories

Advanced range

Modern aesthetics, easy to install and greater user comfort

Note: Cannot be combined with basic range (see page 128)

Description

Wiring centre NEW!

- 6 channels

- 4 actuators (230 V) per channel

- Automatic heating/cooling switchover

Quantity per pack

1

Part number

175140

1 175141

Wiring centre NEW!

- 2 channels

- 4 actuators (230 V) per channel

- Automatic heating/cooling swtichover

Wiring centre (RF) NEW!

- 6 channels

- 4 actuators (230 V) per channel

- Automatic heating/cooling switchover

- Including antenna for wireless communication

Wiring centre (RF) NEW!

- 2 channels

- 4 actuators (230 V) per channel

- Automatic heating/cooling swtichover

- Including antenna for wireless communication

Wiring centre power module NEW!

To supply power to the wiring centres, including:

- Pump input/output for heating and cooling

1

1

1

175143

175144

175137

Wiring centre clock module NEW!

- Removable clock module

- 2 setback timers for heating circuits

Note: To be combined with the wiring centre power module

1 175138

Trade Price

£121.00

£60.00

£227.00

£151.00

£113.00

£60.00

Price List 2015 129

Daikin UK Price List 2015

Applied

Daikin Chillers

132

Water Chillers

Chilled Water Fan Coils

133

135

Scotland

Region

0845 641 9330

Northern

Region

0845 641 9340

Midlands

Region

0845 641 9370

Western

Region

0845 641 9320

North

London

0845 641 9360

South

London

0845 641 9355

Daikin Chillers

Whatever your needs in climate control or process chilling, there is a system that has proved its value in many situations – from factories and warehouses to hotels and department stores, from residential applications to district cooling.

Daikin’s ranges of air-cooled and water-cooled chillers are designed to suit every application – large or small – offering the ultimate in flexibility and control. The unique combination of advanced technology, experience and reliability make Daikin chillers the ideal choice.

Daikin chillers have nominal cooling capacities of 5kW to 2,000kW

(air-cooled) or 13kW to 2,156kW (water-cooled).

Highest efficiency

Using the latest technology, Daikin achieves industry-leading efficiency and energy-saving operation for outstanding cost saving performance.

> Lowest total cost of ownership

> Fast payback time

> Environment-friendly solutions

Worldwide experience

A global leader in HVAC solutions, Daikin has the world’s most advanced facilities for air conditioning research and development: the Applied Development Center, Minneapolis, Minnesota.

> In-house manufacture of main chiller components (compressors, fans, condenser coils, software).

Quality, reliability

> Zero defect policy ensures quality of components and finished products

> All chillers factory run and subjected to quality audit before shipment

> Eurovent and AHRI certification

132 Residential, Commercial and Industrial

Air Cooled Water Chillers

Model

No

Nominal

Cooling kW

Nominal

Heating kW

Power

Supply

Trade

Price

Air Cooled Inverter Packaged Swing / Scroll Compressor –

R410a c/w Hydraulic Pump and Expansion Vessel

EWAQ005ADVP

EWAQ006ADVP

EWAQ007ADVP

5.20

6.00

EWAQ009ACV3P

EWAQ010ACV3P

7.10

8.60

9.60

EWAQ011ACV3P

11.10

EWAQ009ACW1P

9.10

EWAQ011ACW1P

11.10

EWAQ013ACW1P

13.30

-

-

-

-

-

-

-

-

1-phase

1-phase

1-phase

1-phase

1-phase

1-phase

3-phase

3-phase

3-phase

£2,061.00

£2,259.00

£2,503.00

£2,856.00

£3,023.00

£3,249.00

£2,980.00

£3,276.00

£3,471.00

Air Cooled Inverter Packaged Scroll Compressor – R410a

EWAQ016BAWN

EWAQ021BAWN

EWAQ025BAWN

EWAQ032BAWN

EWAQ040BAWN

EWAQ050BAWN

EWAQ064BAWN

17.4

21.7

25.8

32.3

43.4

51.8

64.5

-

-

-

-

-

-

3-phase

3-phase

3-phase

3-phase

3-phase

3-phase

3-phase

£4,714.00

£5,550.00

£6,260.00

£7,223.00

£9,552.00

£10,643.00

£12,290.00

Notes: i) Please contact your local sales office for further information on these products – Download information from www.daikin.co.uk

ii) Nominal cooling capacities are based on 35°C ambient, chilled water @ 12/7°C iii) EWAQ -A series only operates in cooling down to ambients of +10°C iv) The EWAQ064BA delivery does not include offloading to kerbside.

Additional costs for delivery with a Hi-ab are available on request

Product Overview 2015 – Air Cooled Water Chillers

kW 50 100 250 500 750 1000 1250

Fitted Options:

To Fit Model EWAQ-A

Part No

OP10

Description

Evaporator Heater Tape

To Fit Model EWAQ-BA

Part No Description

UK57-BA Evaporator Heater Tape

UK08B-BA Chilled Water Down to -10

UK78-BA

UK79-BA

Low Lift Pump

High Lift Pump

016 021 025 032 040 050 064

£394 £394 £394 £394 £496 £496 £496

£292 £292 £292 £292 £394 £394 £394

£438 £438 £438 £584 £584 £584 £584

£642 £642 £642 £642 £875 £875 £875

1500 2000

EWAQ-ADVP EWAQ-ACV3P EWAQ-ACW1P

005 006 007 009 010 011 009 011 013

£276 £276 £276 £304 £304 £304 £304 £304 £304

Air Cooled Heat Pump Water Chillers

Model

No

Nominal

Cooling kW

Nominal

Heating kW

Power

Supply

Trade

Price

Air Cooled Heat Pump Inverter Packaged Swing / Scroll

Compressor – R410a c/w Hydraulic Pump and Expansion Vessel

EWYQ005ADVP

EWYQ006ADVP

EWYQ007ADVP

EWYQ009ACV3P

5.20

6.00

7.10

EWYQ010ACV3P

EWYQ011ACV3P

8.60

9.60

11.10

EWYQ009ACW1P

9.10

EWYQ011ACW1P

11.10

EWYQ013ACW1P

13.30

5.65

6.35

7.75

9.90

11.40

12.90

10.90

12.40

13.90

1-phase

1-phase

1-phase

1-phase

1-phase

1-phase

3-phase

3-phase

3-phase

£2,380.00

£2,571.00

£2,845.00

£3,288.00

£3,415.00

£3,460.00

£3,415.00

£3,706.00

£3,917.00

Air Cooled Heat Pump Inverter Packaged

Scroll Compressor – R410a

EWYQ016BAWN

EWYQ021BAWN

EWYQ025BAWN

EWYQ032BAWN

EWYQ040BAWN

EWYQ050BAWN

EWYQ064BAWN

17.4

21.7

25.8

32.3

43.4

51.8

64.5

16.2

20.3

24.6

30.7

40.6

49.0

61.5

3-phase

3-phase

3-phase

3-phase

3-phase

3-phase

3-phase

£5,421.00

£6,385.00

£7,202.00

£8,305.00

£10,985.00

£12,237.00

£14,135.00

Notes: i) Please contact your local sales office for further information on these products – Download information from www.daikin.co.uk

ii) Nominal cooling capacities are based on 35°C ambient, chilled water @ 12/7°C iii) Nominal heating capacities are based on 7°C db / 6°C wb ambient, water @ 45 / 50°C iv) EWYQ -A series only operates in cooling down to ambients of +10°C v) The EWYQ064BA delivery does not include offloading to kerbside.

Additional costs for delivery with a Hi-ab are available on request

Product Overview 2015 – Air Cooled Heat Pump Water Chillers

kW 0 50 100 200 300 400 500 600

Fitted Options:

To Fit Model EWYQ-A

Part No Description

OP10 Evaporator Heater Tape

To Fit Model EWYQ-BA

Part No Description

UK57-BA Evaporator Heater Tape

UK08B-BA Chilled Water Down to -10

UK78-BA

UK79-BA

Low Lift Pump

High Lift Pump

EWYQ-ADVP EWYQ-ACV3P EWYQ-ACW1P

005 006 007 009 010 011 009 011 013

£276 £276 £276 £304 £304 £304 £304 £304 £304

016 021 025 032 040 050 064

£394 £394 £394 £394 £496 £496 £496

£292 £292 £292 £292 £394 £394 £394

£438 £438 £438 £584 £584 £584 £584

£642 £642 £642 £642 £875 £875 £875

Price List 2015 133

Water Cooled Chillers

Model

No

Nominal

Cooling kW

Nominal

Heating kW

Power

Supply

Trade

Price

Water Cooled Packaged Scroll Compressor – R407C

EWWP014KBW1N

12.90

EWWP022KBW1N

21.40

EWWP028KBW1N

27.80

EWWP035KBW1N

32.30

EWWP045KBW1N

42.80

EWWP055KBW1N

55.70

EWWP065KBW1N

64.70

-

-

-

-

-

-

3-phase

3-phase

3-phase

3-phase

3-phase

3-phase

3-phase

£2,909.00

£3,439.00

£3,951.00

£4,598.00

£5,664.00

£6,326.00

£7,065.00

Notes: i) Please contact your local sales office for further information on these products – Download information from www.daikin.co.uk

ii) Nominal cooling capacities are based on chilled water @ 12/7°C, condenser water @ 30/35°C

Product Overview 2015 – Water Cooled Chillers

kW 50 100 250 500 750 1000 1250 1500 2000

Fitted Options:

To Fit Model EWWP-KAW1N

Part No Description

OPZH

OPZL

Chilled Water Down to -5

Chilled Water Down to -10

014 022 028 035 045 055 065

£167 £167 £167 £167 £167 £167 £167

£167 £167 £167 £167 £167 £167 £167

Applied Systems Kit Options

Loose Accessory Options:

Model

DTA104A62

EHMC10A10

EHMC10A80

EHMC15A10

EHMC15A80

EHMC30A10

EHMC30A80

EKAC10C

EKRUMCA

EKBT

EKLS1

EKLS2

EKLS2 X 2

EKRP1HBA

EKRP1AHT

EKRUAHTB

RTD-W

EKCC-W

Description

External control adaptor Low noise & demand limit - EWAQ/EWYQ-BA

HYDRAULIC MODULE -Normal static + anti-freeze protection - EWWP014~022/EWLP012~020

HYDRAULIC MODULE-High static + anti-freeze protection - EWWP014~022/EWLP012~020

HYDRAULIC MODULE-Normal static + anti-freeze protection - EWWP028~035/EWLP026~030

HYDRAULIC MODULE-High static + anti-freeze protection - EWWP028~035/EWLP026~030

HYDRAULIC MODULE-Normal static + anti-freeze protection - EWWP045~065/EWLP040~065

HYDRAULIC MODULE-High static + anti-freeze protection - EWWP045~065/EWLP040~065

Address card for connection to BMS - EWWP, EWLP (note not available on the modular EWWP)

Remote Control - EWWP, EWLP (needs EKAC10C)

Buffertank 200I

Low noise operation EWLP012~EWWP14

Low noise operation EWLP02~030, EWWP22-35

Low noise operation EWLP040~065, EWWP45-65

Digital I/O PCB - EWAQ / EWYQ - AC

Demand PCB / Inputs - EWAQ/EWYQ-BA (2 x on size 40/50/64)

Remote user interface (in parallel) - EWAQ/EWYQ-BA

MODBUS Interface - EWAQ/EWYQ-BA

Sequence Controller - EWAQ/EWYQ-BA

Trade Price

£221.00

£1,668.00

£1,775.00

£1,775.00

£1,848.00

£1,991.00

£1,991.00

£86.00

£163.00

£1,097.00

£155.00

£155.00

£310.00

£104.00

£104.00

£157.00

£205.00

£640.00

134 Residential, Commercial and Industrial

Product Overview

Fan Coil Units

Fan Coil Units are a highly efficient means of turning a water chiller, heat pump or hot water boiler into an efficient, quiet air conditioning system. These units are an effective solution to provide a comfortable environment for both commercial and residential applications. Daikin offers a wide range of Fan Coil Units for both concealed and exposed applications. Cassette, cased low wall, cased high wall & ducted models are available to suit particular installation requirements. Many of these are available with Brushless Direct Current (BLDC)

Fan Motors providing high energy efficiency and comfort levels. The only moving part in the units is the fan, making them ideal for use in offices, hotels and at home. The goal is to obtain the right solution, both technically and aesthetically.

Price List 2015 135

Product Overview

Fan Coil Units

Type Model

Ceiling mounted cassette

Floor standing unit

Flexi type unit

Wall mounted unit

Concealed ceiling unit

Round flow cassette

- 900 x 900 cassette

- 360° air discharge ensures uniform air flow

- Integrated fresh air intake

- Easy installation in corners

- Standard drain pump with 850 mm lift

4-way blow ceiling mounted cassette

- 600 x 600 cassette

- Integrated fresh air intake

- Horizontal auto swing

- Easy installation in corners

- Standard drain pump with 750 mm lift

Floor standing unit

- For vertical mounting

- Continuous air flow regulation and fan speed modulation

- Up to 70% energy savings

- Low sound levels

Floor standing unit

- For vertical mounting

- Insulated valve packages, no extra drain pan required

- Fast-on connections for electrical options: no tools needed

- Easy maintenance

Flexi type unit

- For horizontal or vertical mouting

- Continuous air flow regulation and fan speed modulation

- Up to 70% energy savings

- Low sound levels

Flexi type unit

- For horizontal or vertical mounting

- Insulated valve packages, no extra drain pan required

- Fast-on connections for electrical options: no tools needed

- Easy maintenance

Concealed flexi type unit

- For horizontal or vertical concealed mounting

- Continuous air flow regulation and fan speed modulation

- Up to 70% energy savings

- Low sound levels

Concealed flexi type unit

- For horizontal or vertical concealed mounting

- Insulated valve packages, no extra drain pan required

- Fast-on connections for electrical options: no tools needed

- Easy maintenance

Wall mounted unit

- High aesthetic cabinet design

- Optimum air distribution

- Easy installation

- 3-speed fan motor

Concealed ceiling unit with medium ESP

- For horizontal concealed mounting

- Instant adjustment to temperature and relative humidity changes

- Available static pressure up to 80 Pa

- Low sound levels

Concealed ceiling unit with medium ESP

- For horizontal concealed mounting

- Available static pressure up to 80 Pa

- 7-speed electrical motors (thermal protection on windings)

- Easy maintenance

Concealed ceiling unit with high ESP

- For horizontal or vertical concealed mounting

- Available static pressure up to 120 Pa

- Easy maintenance

Product name

FWC-BT/BF

FWF-BT/BF

FWZ-AT/AF

FWV-DAT/DAF

FWR-AT/AF

FWL-DAT/DAF

FWS-AT/AF

FWM-DAT/DAF

FWT-CT

FWP-AT

FWB-BT

FWD-AT/AF

Fan motor type Capacity

BLDC

AC

BLDC

AC

BLDC

AC

BLDC

AC

AC

BLDC

AC

AC

Cooling: 5.8 - 8.7 kW

Heating: 7.5 - 12.1 kW

Cooling: 2.0 - 5.2 kW

Heating: 2.9 - 6.7 kW

Cooling: 2.64 - 10.08 kW

Heating: 2.46 - 11.18 kW

Cooling: 1.46 -8.02 kW

Heating: 1.90 - 10.03 kW

Cooling: 2.64 - 10.08 kW

Heating: 2.46- 11.18 kW

Cooling: 1.46 - 8.02 kW

Heating: 1.90 - 10.03 kW

Cooling: 2.64 - 10.08 kW

Heating: 2.46 - 11.18 kW

Cooling: 1.46 -8.02 kW

Heating: 1.90 - 10.03 kW

Cooling: 2.43 - 5.28 kW

Heating: 3.22 - 7.33 kW

Cooling: 2.61 - 6.47 kW

Heating: 5.47 - 12.28 kW

Cooling: 2.61 - 10.34 kW

Heating: 5.47 - 18.78 kW

Cooling: 3.90 - 18.30 kW

Heating: 4.05 - 21.92 kW

Please contact your local sales office

for further information on these products – Download information from www.daikin.co.uk

Capacity conditions

EUROVENT conditions

Cooling

27°C db / 19°C wb - Entering water 7°C - Leaving water 12°C

Heating 4 Pipe

20°C db - Entering water 70°C - Leaving water 60°C

Heating 2 Pipe

20°C db - Entering water 50°C - Flow rate as in cooling mode

136 Residential, Commercial and Industrial

TYPICAL UK cooling conditions

22°C db / 16.0°C wb - Entering water 7°C - Leaving water 12°C

0 Pa External Static Pressure

0% Glycol

FWP & FWD Ducted FCU - Above capacities are based on 30 Pa

External Static Pressure

FWS Uncased - Based on 20 pa external static

New BLDC (Brushless Direct Current)

Inverter Driven Floor Standing Fan Coil Units

Cased Low Wall Mount Type 2-pipe

Capacity UK Total Cooling

Nominal Cooling

Dimensions

Nominal Heating

Height

Width

Depth

Weight

Sound Power

Sound Pressure

Air Flow Rate

Water Connections

Electrical Data

High/Low

High/Low

High

Power Supply

Trade Fan Coil Price

Cased Low Wall Mount Type 4-pipe

Capacity

Dimensions

UK Total Cooling

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Power

Sound Pressure

Air Flow Rate

Water Connections

Electrical Data

High/Low

High/Low

High

Power Supply

Trade Fan Coil Price

kW kW kW mm mm mm kg dBA dBA m

3

/min inch kW kW kW mm mm mm kg dBA dBA m

3

/min inch

£267.00

FWZ02AFN

1.39

2.64

2.46

226

774

564

21

62/28

54/20

9.33

1/2

FWZ02ATN

1.39

2.64

3.47

226

774

564

20

62/28

54/20

9.33

1/2

£291.00

£283.00

FWZ03AFN

2.57

4.96

4.19

226

987

564

26

70/28

62/20

15

1/2

FWZ03ATN

2.57

4.96

6.4

226

987

564

25

70/28

62/20

15

1/2

£303.00

1ph

1ph

£327.00

FWZ06AFN

3.23

6.32

6.45

226

1194

564

33

64/28

56/20

20

1/2

FWZ06ATN

3.23

6.32

7.51

226

1194

564

31

64/28

56/20

20

1/2

£366.00

£407.00

FWZ08AFN

5.11

10.08

10.06

251

1404

564

44

71/28

63/20

27.66

3/4

FWZ08ATN

5.11

10.08

11.18

251

1404

564

41

71/28

63/20

27.66

3/4

£442.00

New BLDC (Brushless Direct Current)

Inverter Driven Flexi Fan Coil Units

Cased Flexi Type 2-pipe

Capacity

Dimensions

UK Total Cooling

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Power High/Low

Sound Pressure

Air Flow Rate

Water Connections

Electrical Data

High/Low

High

Power Supply

Trade Fan Coil Price

Cased Flexi Type 4-pipe

Capacity

Dimensions

UK Total Cooling

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Power

Sound Pressure

Air Flow Rate

Water Connections

High/Low

High/Low

High

Electrical Data Power Supply

Trade Fan Coil Price

kW kW kW mm mm mm kg dBA dBA m

3

/min inch kW kW kW mm mm mm kg dBA dBA m 3 /min inch

£280.00

FWR02AFN

1.39

2.64

2.46

226

774

564

22

62/28

54/20

9.33

1/2

FWR02ATN

1.39

2.64

3.47

226

774

564

21

62/28

54/20

9.33

1/2

£305.00

FWR03ATN

2.57

4.96

6.4

226

987

564

27

70/28

62/20

15

1/2

£301.00

FWR03AFN

2.57

4.96

4.19

226

987

564

28

70/28

62/20

15

1/2

£329.00

1ph

1ph

£349.00

FWR06AFN

3.23

6.32

6.45

226

1194

564

35

64/28

56/20

20

1/2

FWR06ATN

3.23

6.32

7.51

226

1194

564

33

64/28

56/20

20

1/2

£388.00

£445.00

FWR08AFN

5.11

10.08

10.06

251

1404

564

46

71/28

63/20

27.66

3/4

FWR08ATN

5.11

10.08

11.18

251

1404

564

44

71/28

63/20

27.66

3/4

£492.00

Price List 2015 137

New BLDC (Brushless Direct Current)

Inverter Driven Low Static Concealed Flexi Fan Coil Units

Concealed Flexi Type 2-pipe

Capacity UK Total Cooling

Nominal Cooling

Dimensions

Nominal Heating

Height

Width

Depth

Weight

Sound Power

Sound Pressure

Air Flow Rate

Water Connections

Electrical Data

High/Low

High/Low

High

Power Supply

Trade Fan Coil Price

Concealed Flexi Type 4-pipe

Capacity

Dimensions

UK Total Cooling

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Power

Sound Pressure

Air Flow Rate

Water Connections

Electrical Data

High/Low

High/Low

High

Power Supply

Trade Fan Coil Price

kW kW kW mm mm mm kg dBA dBA m

3

/min inch kW kW kW mm mm mm kg dBA dBA m

3

/min inch

£239.00

FWS02AFN

1.08

2.64

2.46

224

584

535

16

62/28

54/20

9.33

1/2

FWS02ATN

1.08

2.64

3.47

224

584

535

15

62/28

54/20

9.33

1/2

£265.00

£257.00

FWS03AFN

2.02

4.96

4.19

224

794

535

20

70/28

62/20

15

1/2

FWS03ATN

2.02

4.96

6.4

224

794

535

19

70/28

62/20

15

1/2

£287.00

1ph

1ph

£293.00

FWS06AFN

2.52

6.32

6.45

224

1004

535

25

64/28

56/20

20

1/2

FWS06ATN

2.52

6.32

7.51

224

1004

535

23

64/28

56/20

20

1/2

£329.00

£366.00

FWS08AFN

3.99

10.08

10.06

249

1214

535

34

71/28

63/20

27.66

3/4

FWS08ATN

3.99

10.08

11.18

249

1214

535

32

71/28

63/20

27.66

3/4

£412.00

Floor Standing and Flexi Fan Coil Unit Accessories

Loose Accessory Options:

FWZ, FWR, FWS

2-pipe 3-way valve kits c/w lockshields

4-pipe 3-way valve kits c/w lockshields

Vertical drainpan

Horizontal drainpan

Advanced Plus Electronic Controller

On board installation kit

(FWZ & FWR - Low Wall Mounted Only)

Return Air Sensor

02-03

E2MV03A6

£121.00

E4MV03A6

£217.00

06

E2MV06A6

£121.00

E4MV06A6

£217.00

EDPVB6

£3.00

EDPHB6

£3.00

FWEC3A

£114.00

FWECKA

£11.00

FWTSKA

£8.00

08

E2MV10A6

£128.00

E4MV10A6

£227.00

Notes: i) Each controller version includes the water probe ii) The on board installation kit includes a remote air probe (if installed the internal fan coil robe is disabled) iii) The FWEC3A can operate up to 247 fan coils as master slave control, plus weekly schedule timer, proportional valve control and 2 digital outputs (1 per fan coil required).

138 Residential, Commercial and Industrial

New BLDC (Brushless Direct Current)

Inverter Driven Medium Static Ducted Fan Coil Units

Concealed Ducted Type 2-pipe

Capacity UK Total Cooling

Nominal Cooling

Dimensions

Nominal Heating

Height

Width

Depth

Weight

Sound Power

Sound Pressure

Air Flow Rate

Water Connections

Electrical Data

High/Low

High/Low

High

Power Supply kW kW kW mm mm mm kg dBA dBA m

3

/min inch

FWP02AT

1.34

2.61

5.47

239

1039

609

24

56/40

44/24

6.66

3/4

FWP03AT

1.67

3.14

6.01

239

1039

609

26

56/40

44/24

6.66

3/4

FWP04AT

2.03

3.49

6.47

239

1039

609

28

56/40

44/24

6.66

3/4

1ph

Trade Fan Coil Price - Naked - No Valve

Trade Fan Coil Price- Complet with 3 - way valve fitted

FWP02ATN

£344.00

FWP02ATV

£422.00

FWP03ATN

£359.00

FWP03ATV

£436.00

FWP04ATN

£373.00

FWP04ATV

£450.00

FWP05ATN

£438.00

FWP05ATV

£514.00

Please note

if you require a 4 pipe fan coil please purchase additional heat exhanger as shown below

FWP05AT

2.5

5.08

10.31

239

1389

609

33

61/39

50/27

13.33

3/4

FWP06ATN

£443.00

FWP06ATV

£519.00

FWP06AT

2.77

5.45

11.39

239

1389

609

35

61/39

50/27

13.33

3/4

FWP07AT

3.47

6.47

12.28

239

1389

609

38

61/39

50/27

13.33

3/4

FWP07ATN

£472.00

FWP07ATV

£549.00

Loose Accessory Options:

FWP

Additional Heat exchanger (4 Pipe) nominal heating cap 3.2kW

Additional Heat exchanger (4 Pipe) nominal heating cap 6.1kW

2-way valve cooling coil

3-way valve add.h/e

2-way valve add.h/e

Advanced Plus Electronic Controller

Return Air Sensor

02 - 04

EAH04A6

£89.00

-

-

E2MV207A6

£51.00

E2MV307A6

£91.00

E2MV207A6

£51.00

FWEC3A

£114.00

FWTSKA

£8.00

05 - 07

-

-

EAH07A6

£103.00

Notes:

i) Each controller version includes the water probe ii) The FWEC3A can operate up to 247 fan coils as master slave control, plus weekly schedule timer, proportional valve control and 2 digital outputs (1 per fan coil required).

Price List 2015 139

AC Fan Motor - 3 speed

High Static Ducted Fan Coil Units

Concealed Ducted Type 2-pipe

Capacity UK Total Cooling

Nominal Cooling

Dimensions

Nominal Heating

Height

Width

Depth

Weight

Sound Power

Sound Pressure

Air Flow Rate

Water Connections

Electrical Data

High / Low

High / Low

High

Power Supply

Trade Fan Coil Price

Concealed Ducted Type 4-pipe

Capacity

Dimensions

UK Total Cooling

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Power

Sound Pressure

Air Flow Rate

Water Connections

Electrical Data

High / Low

High / Low

High

Power Supply

Trade Fan Coil Price

kW kW kW mm mm mm kg dBA dBA m

3

/min inch kW kW kW mm mm mm kg dBA dBA m

3

/min inch

£270.00

FWD04AF

2.15

3.9

4.05

280

754

559

35

66/54

56/46

13.33

3/4

FWD04AT

2.15

3.9

4.05

280

754

559

33

66/54

56/46

13.33

3/4

£316.00

FWD06AT

3.48

6.2

7.71

280

964

559

41

69/59

61/51

20.83

3/4

£413.00

£355.00

FWD06AF

3.48

6.2

7.71

280

964

559

43

69/59

61/51

20.83

3/4

£415.00

FWD08AF

4.44

7.8

9.43

280

1174

559

50

72/62

64/54

26.67

3/4

FWD08AT

4.44

7.8

9.43

280

1174

559

47

72/62

64/54

26.67

3/4

£482.00

£462.00

FWD10AF

4.92

8.82

10.79

280

1174

559

52

72/62

64/54

26.67

3/4

1ph

FWD10AT

4.92

8.82

10.79

280

1174

559

49

72/62

64/54

26.67

3/4

1ph

£545.00

£735.00

FWD16AF

8.96

16.4

19.81

352

1384

718

83

78/69

70/61

50

1

FWD16AT

8.96

16.4

19.81

352

1384

718

77

78/69

70/61

50

1

£853.00

£574.00

FWD12AF

7.21

11.9

14.45

352

1174

718

71

74/60

66/52

36.67

1

FWD12AT

7.21

11.9

14.45

352

1174

718

65

74/60

66/52

36.67

1

£672.00

£808.00

FWD18AF

9.91

18.3

21.92

352

1384

718

86

78/69

70/61

50

1

FWD18AT

9.91

18.3

21.92

352

1384

718

80

78/69

70/61

50

1

£935.00

Loose Accessory Options:

FWD

2-pipe 3-way valve

4-pipe 3-way valve

Vertical Drain pan

Horizontal Drain Pan

Master slave interface

Power interface (S)

Standard Electronic Controller

Advanced Electronic Controller

Advanced Plus Electronic Controller

Return Air Sensor

4

ED2MV04A6

£128.00

ED4MV04A6

£244.00

6 8 -10

ED2MV10A6

£128.00

ED4MV10A6

£244.00

EDDPV10A6

£11.00

EDDPH10A6

£13.00

EPIMSA6

£84.00

EPIB6

£84.00

FWEC1A

£65.00

FWEC2A

£82.00

FWEC3A

£114.00

FWTSKA

£8.00

12 16 -18

ED2MV12A6 ED2MV18A6

£128.00

£133.00

2x ED2MV12A6 2 x ED2MV18A6

£256.00

£266.00

EDDPV18A6

£11.00

EDDPH18A6

£13.00

-

-

Notes:

FWEC1A is designed as an individual unit controller. Power interface EPIB6 is required for unit size 16 and 18 can operate up to

4 fan coils by adding a EPIMSA6.

If using this controller to operate up to 4 fan coil units by adding a EPIMSA6 you will require a EPIB6 power interface for unit size 12,16,18.

FWEC2A can operate up to 247 fan coils as master slave control ( 1 per fan coil required).

Power interface EPIB6 is required for each unit size 16 and 18.

FWEC3A can operate up to 247 fan coils as master slave control, plus weekly schedule timer, proportional valve control

(by others) and 2 digital outputs ( 1 per fan coil required).

Please note that:

i) Each controller version includes the water probe.

140 Residential, Commercial and Industrial

AC Fan Motor - 3 speed

600 Sq Cassette Fan Coil Units

600sq Cassette Type 2-pipe c/w Decoration Panel BYFQ60B3

Capacity UK Total Cooling kW

Nominal Cooling kW

Dimensions

Nominal Heating

Height

Width

Depth

Weight

Sound Power

Sound Pressure

Air Flow Rate

Water Connections

Electrical Data

High / Low

High / Low

High

Power Supply kW mm mm mm kg dBA dBA m

3

/min inch

Trade Fan Coil Price

600sq Cassette Type 4-pipe c/w Decoration Panel BYFQ60B3

Capacity

Dimensions

UK Total Cooling

Nominal Cooling

Nominal Heating

Height

Width kW kW kW mm mm

Weight

Sound Power

Sound Pressure

Air Flow Rate

Water Connections

Electrical Data

Depth

High / Low

High / Low

High

Power Supply mm kg dBA dBA m

3

/min inch

Trade Fan Coil Price

FWF02BT

1.20

2

2.9

260

575

575

19

44/36

31/26

7.9

£541.00

£509.00

FWF02BF

1.10

2

3.9

260

575

575

19

44/36

31/26

7.9

FWF03BT

1.9

3.2

4

260

575

575

19

44/36

31/26

7.9

3/4 “ BSP Female

1 ph

FWF04BT

2.5

4.2

5.4

260

575

575

19

50/36

40/26

11.2

£535.00

£565.00

FWF03BF

1.6

2.7

3.8

260

575

575

20

44/36

31/26

7.2

3/4 “ BSP Female

1 ph

FWF04BF

2

3.5

4.9

260

575

575

20

50/36

40/26

10.4

£565.00

£603.00

£603.00

FWF05BF

2.5

4.5

6.1

260

575

575

20

55/42

45/30

13.9

FWF05BT

3.1

5.2

6.7

260

575

575

19

55/42

45/30

14.9

£637.00

BLDC Fan Motor - 3 speed

Cassette Fan Coil Units

Cassette Type 2-pipe c/w Decoration Panel BYCQ140C

Capacity

Dimensions

UK Total Cooling

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Power High / Low

Sound Pressure

Air Flow Rate

Water Connections

Electrical Data

High / Low

High

Power Supply kW kW kW mm mm mm kg dBA dBA m 3 /min inch

Trade Fan Coil Price

Cassette Type 4-pipe c/w Decoration Panel BYCQ140C

Capacity

Dimensions

UK Total Cooling

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Power

Sound Pressure

Air Flow Rate

High / Low

High / Low

High

Water Connections

Electrical Data Power Supply kW kW kW mm mm mm kg dBA dBA m

3

/min inch

Trade Fan Coil Price

£621.00

FWC06BF

3.30

5.8

7.5

288

840

840

29

43/31

29/21

17.1

FWC06BT

3.30

5.8

8

288

840

840

26

43/31

29/21

17.7

£649.00

FWC07BT

4.1

6.8

8.9

288

840

840

26

47/33

33/22

20.6

3/4 “ BSP Female

1 ph

FWC08BT

4.3

7.7

10.6

288

840

840

26

53/36

39/24

25.4

£637.00

£653.00

FWC07BF

4

6.6

8.4

288

840

840

29

47/33

33/22

19.9

3/4 “ BSP Female

1 ph

FWC08BF

4.3

7.6

9.7

288

840

840

29

53/36

39/24

24.6

£673.00

£691.00

£681.00

FWC09BF

4.8

8.7

11

288

840

840

29

57/40

43/28

29

FWC09BT

4.8

8.7

12.1

288

840

840

26

57/40

43/28

30.8

£708.00

Price List 2015 141

Cassette Accessories

Loose Accessory Options:

FWF/FWC

Remote wired controller

Intelligent touch controller

Unit/Group adapter pcb

Unit/Group adapter pcb complete with installation box

System adaptor pcb

System adaptor pcb complete with installation box

Optional pcb for connection to ModBus

(2 stopbit)

2-Way on / off valve kit

3-Way on / off valve kit

Valve control PCB

FWF/FWC

BRC315D

£67.00

DCS601C51

£1,641.00

KRP4A53

£67.00

KRP4A53/UK.FB2

£92.00

KRP2A52

£177.00

KRP2A52/UK.FB2

£202.00

EKFCMBCB

£55.00

EKMV2C09B

£58.00

EKMV3C09B

£64.00

EKRP1C11

£100.00

FWC only

Wireless remote control heat pump

Wireless remote control cooling only

Remote air sensor

Installation box for an EKRP1C11 valve PCB

FWF only

Wireless remote control heat pump

Wireless remote control cooling only

Remote air sensor

Remote on/off control interface kit

Installation box for an EKRP1C11 valve PCB

FWC only

BRC7FA532F

£152.00

BRC7F533F

£121.00

KRCS01-4

£42.00

KRP1H98

£37.00

FWF only

BRC7E530

£121.00

BRC7E531

£121.00

KRCS01-1

£46.00

EKRORO

£16.00

KRP1BA101

£43.00

Notes: i) FWF and FWC Cassette Fan Coil prices include decoration panel ii) It is not possible to use Intelligent Touch control for combination with both VRV and water based fan coils

FWF-Valve control requirements

2 pipe unit: 1 x valve kit + 1 x installation box for PCB KRP1BA101 + 1 x valve control

PCB EKRP1C11

4 pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1BA101 + 1 x valve control

PCB EKRP1C11

FWC-Valve control requirements

2 pipe unit: 1 x valve kit + 1 x installation box for PCB KRP1H98 + 1 x valve control

PCB EKRP1C11

4 pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1H98 + 1 x valve control

PCB EKRP1C11

AC Fan Motor - 3 speed

Wall Mounted Fan Coil Units

Cased High Wall Mount Type 2-pipe

Capacity UK Total Cooling

Dimensions

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Power

Sound Pressure

Air Flow Rate

Water Connections

Electrical Data

High / Low

High / Low

High

Power Supply

Trade Fan Coil Price

kW kW kW mm mm mm kg dBA dBA m

3

/min inch

FWT02CT

1.59

2.43

3.22

288

800

206

10

45/36

34/25

7.36

1/2

£196.00

Loose Accessory Options:

FWT

Standard wired remote controller

Simplified wired remote controller

Wireless controller for heat pump

FWT

MERCA

£76.00

SRC-HPA

£39.00

WRC-HPC

£15.00

FWT03CT

1.67

2.7

3.52

288

800

206

10

48/39

35/25

7.93

1/2

£204.00

FWT04CT

2.1

3.31

4.4

288

800

206

10

55/45

42/32

10.48

1/2

1ph

£234.00

FWT05CT

2.9

4.54

6.01

310

1065

224

15

55/47

42/34

14.43

1/2

£283.00

FWT06CT

3.41

5.28

7.33

310

1065

224

15

59/51

42/39

17.55

1/2

£301.00

Notes: i) FWT fan coils are optimised for valveless control in cooling. We would recommend that a valve is fitted if being used for heating only and for more precise control in cooling.

ii) We would recommend the field supply of a 240V - 4 port 3 way valve complete with

240V actuator.

142 Residential, Commercial and Industrial

Daikin UK Price List 2015

Miscellaneous

Delivery Information

Goods Returns Procedure

Field Quality Service (FQS)

Daikin Service Tools

Training 148

Terms & Conditions 150

144

145

146

147

Scotland

Region

0845 641 9330

Northern

Region

0845 641 9340

Midlands

Region

0845 641 9370

Western

Region

0845 641 9320

North

London

0845 641 9360

South

London

0845 641 9355

Delivery Information

Material Code Description

Standard Delivery Mon - Fri 8:00 to 17:00 (excluding Spares)

Standard delivery Standard delivery

Cost

Included

Order processing deadline

Order processed by 14:00 Day 1 Delivery Day 2

Standard Hours (8:00 - 17:00) Timed Deliveries (excluding Spares)

UK.DLVWIN1

8:00 - 13:00 weekdays

UK.DLVWIN2

UK.TDN_30min

13:00 - 17:00 weekdays

Time specific 30 min window during standard hours

£50.00

£45.00

£220.00

Order processed by 14:00 Day 1 Delivery Day 2

Order processed by 14:00 Day 1 Delivery Day 2

Order processed by 14:00 Day 1 Delivery Day 2

Outside Standard

UK.TDO_30min

UK.RUSH

Time specific 30 min window outside standard hours

Same day delivery (geographical restrictions apply)

£290.00

£220.00

Order processed by 14:00 Day 1 Delivery Day 2

Order processed 11:00

Weekend Deliveries excluding Spares

UK.TDO_30min

UK.SAT_Courrier

UK.SAT_Sub

Time specific 30 min window outside standard hours

Less than 15KG

Greater than 15KG

£290.00

£35.00

£110.00

Order processed by 14:00 Day 1 Delivery Day 3 or 4 (as requested)

Order processed by 14:00 Day 1 Delivery Day 2

Order processed Day 1 Delivery Day 3

Public holidays - request for deliveries on public holidays are considered on an individual basis

Special Vehicles Standard Delivery Monday to Friday

UK.Special

UK.Van

Hiab (includes time slot)

Flat bed (includes time slot)

Transit van (size restrictions)

£340.00

£100.00

Order processed by 14:00 Day 1 Delivery day 3

Order processed by 14:00 Day 1 Delivery Day 2

Special Vehicles Weekends

UK.Special

Hiab (includes time slot)

£340.00

Order processed by 14:00 Day 1 Delivery Day 3 or 4 (as requested)

UK.Van

Flat bed (includes time slot)

Transit van (size restrictions)

£100.00

Order processed by 14:00 Day 1 Delivery Day 2

Public holidays - request for deliveries on public holidays are considered on an individual basis

Notes:

> Weekday = Monday to Friday

8:00 to 17:00

> Standard delivery vehicle is 17.5 ton lorry or smaller with tail lift

> Amendment or cancellation after order entry deadline maybe subject to additional costs

> Time specific is a requested delivery time plus or minus

30 mins

> Two man deliveries can be requested for heavier items and deliveries above ground level

> Delivery address, site contact name and number are provided and any delivery restrictions must be communicated prior to order entry deadline

> Driver is not permitted to make part delivery against a delivery note. Additional charges may apply for refused deliveries

> 48 hours notice required for Hi-ab requests

> 95% of mainland UK deliveries

= next day

> For Transportation Lead Times see http://www.daikin.co.uk/ business-partners/index.jsp

144 Residential, Commercial and Industrial

Goods Returns Procedure

Daikin UK policy for acceptable returned goods

Daikin UK policy for acceptable returned goods is as follows:

Units & Accessories: 10 working days from date of invoice

Spare Parts: 1 month from date of invoice

Daikin may accept unwanted goods provided they are boxed in the original packaging, in perfect condition and have not been used – provided they are also within the time scales of the Daikin returns policy. To arrange the process of returning goods, please complete a Goods Returns Form available from

www.daikin.co.uk/business-partners/trade and send by fax or email to the following:

Units & Accessories:

Fax: 0845 641 9150 or email: [email protected]

Spare Parts:

Fax: 0845 641 9299 or email: [email protected]

Conditions of Returned Goods

All returned items are subject to a minimum 20% restocking/ administration charge with the following collection charges applied to the final credit:

Collected goods up to 15KG: £15

Collected goods over 16KG: £90

All returned goods will be fully inspected by our technical engineers. If returned goods are in a non-satisfactory condition then Daikin reserves the right to decline the return or apply an increase to the restocking charge.

Damaged Items

We cannot accept claims for damages unless the goods are signed for as damaged on the delivery note and notification is received within 3 working days. Any damage identified can be refused at point of delivery.

If you find that goods are damaged after they have been unpacked, please take photographs of the damage and contact the Returns Team immediately.

What Happens Next

Once the Goods Return Form is received, an email will be sent to the confirmation email address provided notifying you of the goods for collection and a date for this to be carried out.

If you have any queries regarding this date please respond to the email address provided as soon as possible.

Once inspected and confirmation is received that the goods are in perfect condition, a credit will be raised against the original invoice.

*Please note returns for chillers and made to order units will not be accepted*

Goods Covered by Warranty

Once a unit has been installed and commissioned, any faults or breakdowns that occur should be reported to our warranty department on:

Telephone: 0845 641 9275 or email: [email protected]

Price List 2015 145

The Field Quality Service department (FQS)

The Field Quality Service department (FQS) supply a range of services to support the installer.

Aftersales Technical Helpdesk

This invaluable service offers technical support and guidance when you are experiencing on-site problems commissioning or diagnosing faults. Final diagnosis is the responsibility of the site engineer.

Your calls will be answered by Daikin trained engineers. To help provide a quick and efficient response please make sure you have the full model number of the unit. It is important to remind you that using the D1/D1+ PIN number gives you priority access to our engineers.

Workshop

In our workshop on the outskirts of Bristol we modify standard

Daikin equipment to current specifications that meet our client’s needs. The modifications include weatherised vams, floor mounted fan coil conversions, strip and rebuild to name a few. Think of the savings in time and money by having your next VRV outdoor unit delivered to site in sections for placing in position on the roof, saving at the cost of cranes and road closure applications. Speak to your sales representative for more information on what is available.

Support for Air Conditioning contact:

0845 641 9200

Mon - Fri 8.30 - 17.30

Support for Heating contact:

0845 641 9277

Mon - Fri 8.30 - 20.00 & Sat 9.00 - 15.00

Email [email protected]

SMS Fault Code Service 07797 801908

Spares

When a component fails, field expertise is pointless unless you have quick access to spares. Daikin have over 13,000 parts based in the

UK, supported by our European parts centre with 700,000 parts.

This helps us to achieve our target of providing 97% of critical A parts within a 2 day delivery.

To contact the spares team directly

Tel 0845 641 9230

Fax 0845 641 9299

Email [email protected]

If you need an explanation and remedy on a fault code and haven’t got your service manual, just send the fault code to our SMS message service and we will advise you by return.

Field Service

We can provide field engineers to assist you on-site for commissioning or service intervention. All work is documented in a report and sent for your records. Since we are working on your site on your behalf it is essential that you are in attendance at that time.

If you hold a direct account with Daikin UK, you can send your spare parts order to us directly using our Spares Parts Bank.

This is available 24 hours a day 365 days a year, and allows you to view and order your parts online at any time of day. Plus, all orders processed through Spares Parts Bank have no delivery charge, which is equivalent to almost 5% extra discount.

To register for Spares Parts Bank go to www.daikin.co.uk/spares

To book an engineer contact us on:

Tel 0845 641 9229 or contact us online at www.daikin.co.uk/service/support

For Heating email: [email protected]

For Air Conditioning email: [email protected]

Daikin UK Warranty

If you have a component failure and it is within the warranty period then we are here to help. After you have spoken to our helpdesk to confirm diagnosis, you can simply contact the warranty team.

Contact the warranty team on:

Tel 0845 641 9275

Fax 0845 641 9298

Email [email protected]

For further details on Daikin’s warranty policies go to www.daikin.co.uk/service/warranty

Here you will find process claim forms and our full warranty terms.

146 Residential, Commercial and Industrial

Daikin Service Tools

Daikin Service App

The Daikin Service Application has been launched by Daikin

Airconditioning UK to support service engineers in the air conditioning industry working with Daikin VRV Equipment.

Service Checker (Part No. 999165T)

The service checker type 3 can read and record the operational data from various Daikin equipment. This data consists of thermistor readings, pressure sensor values, solenoid valve operation, expansion valve pulses, operation modes etc.

Software version 1.53 or later is required for connection to VRV IV systems.

It’s available for both the

android and iPhone devices.

The application covers various functions to help field engineers to fault find Daikin VRV equipment such as:

Android functions

Fault Codes

VRV Additional Charge Calculation

Replacement PCB Dip Switch Settings

Pressure Transducer and Temperature Thermistor Checks

Also various Outdoor Unit field settings including,

Fan Coil and BSVQ Box Count Check

Refrigerant Recovery Setting

Outdoor Unit Emergency Modes

VRV III & IV Short Test Run

There is Also Daikin Altherma support for,

Fault Codes

Additional Refrigerant Charges

C Series Altherma Field Settings

Dip Switch Settings and much more...

iPhone functions

Fault Codes

VRV Additional Charge Calculation

Replacement PCB Dip Switch Settings

Pressure Transducer and Temperature Thermistor Checks

Also various Outdoor Unit field settings including,

Fan Coil and BSVQ Box Count Check

Refrigerant Recovery Setting

Outdoor Unit Emergency Modes

VRV III Short Test Run

To Download the Apps go to:

Android:

https://play.google.com/store/apps/details?id=com.daikin.

aircon&hl=en

iPhone:

https://itunes.apple.com/us/app/daikin-service/id571282882?mt=8

DChecker

The DChecker is a service tool used to capture operational data from the following equipment, Split-Multisplit, Sky-air & Altherma products. This will record and graph all sensor data, PCB inputs & outputs from indoor and outdoor units. From the operational data this will help to identify any operational issue.

Please note the DChecker is a USB interface which provides a direct wired link to the main PCBS and enables real-time data to be viewed on a laptop running windows. Software included.

Inverter Analyser RS UK0917A (Part No. 136 8521)

The inverter analyser can be used to check the inverter outputs on all VRV models (can also be used on various split & sky air units).

Price List 2015 147

Daikin UK’s Customer Training

In 2015 Daikin UK will be introducing new and innovative training possibilities. We have spent 2014 investing in new Training Centres, Web Platforms and equipment upgrades. This year we will be focusing on ensuring that training you receive will be more relevant to the changing market and to assist you to provide your customers with the highest quality installations.

Training Centres

As well as upgrading our existing centres with new products, we have invested in two new centres in Woking and Birmingham.

The Birmingham training centre covers an area of over 200m 2 and is adjacent to the newly relocated sales office complex, providing hands on training on the latest Split, VRV, Altherma and control systems.

The new Woking dedicated technology centre represents the largest Daikin training facility in the UK, over two floors, covering an area close to 1000m

2

. The facility is able to hold three training events at one time, with additional equipment demonstration facilities and a dedicated suite for conducting Web based live training events. The centre includes VRV Heat Recovery, VRV Heat

Pump, Water Cooled VRV, Replacement VRV as well as a variety of split systems.

With the increasing focus on energy controls, a specially designed controls wall has been constructed to allow for the many different configuration possibilities of individual and central controls together with the many BMS interface options.

The first floor is dedicated to Heating products with 8 individual working bays containing a wide selection of systems to allow for practical hands on training of commissioning and fault diagnosis.

The award winning Altherma Hybrid system is installed in each of these 8 bays giving each attendee the possibility for a high level of experiential training.

Daikin UK Training Centres

1 Bristol

Daikin Airconditioning UK Limited

Maple House, Brotherswood Court,

Great Park Road, Almondsbury,

Bristol BS32 4QW

2 Woking

Daikin Airconditioning UK Limited

21 Woking Business Park, Albert Drive,

Woking, Surrey GU21 5JY

3 Birmingham

Daikin Airconditioning UK Limited

2470 Regents Court, The Crescent,

Birmingham Business Park,

Birmingham B37 7YE

4

Manchester

Daikin Airconditioning UK Limited

17b Cobra Court, Blackmore Road,

Manchester M32 0QY

5 Glasgow

Daikin Airconditioning UK Limited

Unit 2, Glasgow Airport Business Park,

Marchburn Drive, Paisley PA3 2SJ

6 PGL Training

Clyst Works, Clyst Road, Topsham,

Exeter EX3 0DB

7 Dudley Energy Training Hub

Dudley College Training Ltd

3-4 Railway Street, Great Bridge,

Tipton DY4 7AD

Industry Accreditation

Heat Pump courses with EAL accreditation are also available at our partner colleges. These courses count towards MCS

(Microgeneration Certification Scheme), whilst at the same time providing the necessary knowledge to install Daikin Altherma

Products. Our partner colleges include Dudley Energy Training Hub and PGL Training in Exeter. More details are available in the separate

Daikin UK Training brochure.

To find out when courses are scheduled at regional Daikin UK training centres, check availability and book a place: please go to the Daikin UK booking web site at

www.daikintraining.co.uk

148 Residential, Commercial and Industrial

Course Subjects

For anyone operating in the HVACR market, skills and knowledge requirements are getting wider with each year. Daikin UK recognise that our training offer needs to expand to provide opportunities to anyone operating in this industry.

At the same time the demands on your time is increasing, and we have been looking at new and innovative ways to provide the knowledge and skills you need.

During 2015 we will be introducing a wider range of courses together with new web based short courses that can be followed through whichever mobile platform you prefer.

The new courses will cover more application and design subjects,

Legislation, Fundamental Technical subjects and also personal development in areas such as Presentation and Selling skills.

As these courses become available it will be possible to reserve places through our Web Based booking platform. We will announce more specific details throughout the year.

Within our new Woking Technology Centre we have installed a web based broadcast facility. From here we will provide a series of short courses across a range of subjects. The majority of these will also be recorded and made available through a new web based training platform that will be introduced by the middle of 2015.

Users will be able to register as an individual to undertake web based training and each user will have a system account that enables them to review past training they have undertaken and the ability to print of training records and certificates.

2015 represents a change in our training approach that will provide you with a greater range of subjects, new ways to obtain skills and knowledge and more experiential classroom training.

Further details can be found in the Daikin UK 2015 Training

Brochure and on line at www.daikintraining.co.uk

Price List 2015 149

RW Refrigeration Wholesale Ltd

Terms and Conditions

1 Price

1.1 The price quoted excludes VAT (unless otherwise stated). VAT will be charged at the rate applying at the time of delivery.

1.2 Our quotations lapse after 30 days (unless otherwise stated).

1.3 If your order is for goods less than £15.00 you will be charged a minimum invoice charge of £15.00.

1.4 The price quoted includes standard next day delivery in Great Britain and Northern

Ireland (excluding the Scottish Highlands and Islands) by a method of transport selected by us if the value of the goods ordered is £50.00 or more (unless otherwise stated.)

1.5 The price quoted excludes express delivery or delivery within Great Britain and

Northern Ireland (excluding the Scottish Highlands and Islands) by a method requested by you which is not usually used by us.

1.6 The price quoted excludes returnable cylinders. The cost of returnable cylinders will be charged at the price current at the time of delivery unless they are returned to us in good condition and within 30 days of receipt. The supply of returnable cylinders is subject to our standard conditions from time to time in force.

1.7 Unless otherwise stated, the price quoted is an illustrative estimate only and the price charged will be our price current at the time of delivery.

1.8 Rates of tax and duties on the goods will be those applying at the time of delivery.

1.9 At any time before delivery we may adjust the price to reflect any increase in our costs of supplying the goods.

2 Delivery

2.1 All delivery times quoted are estimates only.

2.2 If we fail to deliver within a reasonable time after the quoted delivery time, you may

(by informing us in writing) cancel the contract, however:

2.2.1 you may not cancel if we receive your notice after the goods have been dispatched and

2.2.2 if you cancel the contract, you can have no further claim against us under that contract.

2.3 If you accept delivery of the goods after the estimated delivery time, it will be on the basis that you have no claim against us for delay (including indirect or consequential loss, or increase in the price of the goods).

2.4 We may deliver the goods in instalments. Each instalment is treated as a separate contract.

2.5 We may decline to deliver if:

2.5.1 we believe that it would be unsafe, unlawful or unreasonably difficult to do so

2.5.2 the premises (or the access to them) are unsuitable for our vehicle or our carriers vehicle or

2.5.3 you do not ensure that there is responsible person available to receive the goods within a reasonable time of our arrival or our carriers arrival.

3 Risk

3.1 The goods are at your risk from the time of delivery.

3.2 Delivery takes place either:

3.2.1 at our premises (if you are collecting them or arranging carriage) or

3.2.2 at your premises or address specified by you (if we are arranging carriage).

3.3 You must inspect the goods on delivery. If any goods are damaged or not delivered, you must write to tell us within five days of delivery or the expected delivery time. You must give us (and any carrier) a fair chance to inspect the damaged goods.

4 Payment terms

4.1 You are to pay us in cash or in cleared funds on delivery, unless you have an approved credit account.

4.2 If you have an approved credit account, payment is due no later than 30 days after the date of our invoice unless otherwise agreed in writing.

4.3 If you fail to pay us in full on the due date we may:

4.3.1 suspend or cancel future deliveries

4.3.2 cancel any discount offered to you

4.3.3 charge you interest at the rate set under s.6 of the Late Payment of Commercial

Debts (Interest) Act 1998 a .calculated (on a daily basis) from the date of our invoice until payment b. before and after any judgment (unless a court orders otherwise)

4.3.4 claim fixed sum compensation from you under s.5A of that Act to cover our credit control overhead costs and

4.3.5 recover (under clause 4.7) the cost of taking legal action to make you pay.

4.4 If you have an approved credit account we may withdraw it or reduce your credit limit or bring forward your due date for payment. We may take any of these actions at any time and without notice.

4.5 You do not have the right to set off any money you may claim from us against anything you may owe us.

4.6 While you owe money to us, we have a right to keep any property we may hold of yours until you have paid us in full (a lien).

4.7 You are to indemnify us in full and hold us harmless from all expenses and liabilities we may incur (directly or indirectly and including finance costs, legal costs on a full indemnity basis and the costs of instructing a debt collection agency to recover a debt due to us if any) following any breach by you of any of your obligations under these terms.

5 Title

5.1 Until you pay all debts you may owe us:

5.1.1 all goods supplied by us remain our property

5.1.2 you must store them so that they are clearly identifiable as our property

5.1.3 you must insure them (against the risks for which a prudent owner would insure them) and hold the policy on trust for us

5.1.4 you may use those goods and sell them in the ordinary course of your business, but not if: a. we revoke that right (by informing you in writing) or b. you become insolvent.

5.2 You must inform us (in writing) immediately if you become insolvent.

5.3 if your right to use and sell the goods ends you must allow us to remove the goods.

5.4 We have your permission to enter any premises where the goods may be stored:

5.4.1 at any time, to inspect them and

5.4.2 after your right to use and sell them has ended, to remove them, using reasonable force if necessary.

5.5 Despite our retention of title to the goods, we have the right to take legal proceedings to recover the price of goods supplied should you not pay us by the due date.

5.6 You are not our agent. You have no authority to make any contract on our behalf or in our name.

6 Warranties

6.1 We warrant that the goods:

6.1.1 comply with their description on our acknowledgement of order form and

6.1.2 are free from material defect at the time of delivery (as long as you comply with clause (6.3)

6.2 We give no other warranty (and exclude any warranty, term or condition that would otherwise be implied) as to the quality of the goods or their fitness for any purpose.

6.3 If you believe that we have delivered goods which are defective in material or workmanship, you must:

6.3.1 inform us (in writing), with full details, within 7 days of becoming aware of the failure

6.3.2 allow us and the manufacturer to investigate (we may need access to your premises and product samples). We may request that you return the goods to us for inspection at your own expense.

6.4 We may issue replacement goods to you while we investigate your claim. If so, you must:

6.4.1 pay the price in full of the replacement goods to us and

6.4.2 pay the full price of the original goods to us (and accept their return) if , on investigation, they are not found to be defective.

6.5 If the goods are found to be defective in material or workmanship (following our investigations), and you have complied with those conditions (in clause 6.3) in full, we will (at our option) repair the goods, replace the goods or refund the price subject to clause 6.6 below.

6.6 As we are not the manufacturer of the goods, our liability is limited to the balance of any benefit that we may receive under any manufacturer warranty or guarantee of the goods.

6.7 Where goods are returned to us for repair or inspection under warranty:

6.7.1 you will pay the cost of sending the goods to us for repair or inspection

6.7.2 you must enclose with the returned goods a properly completed warranty claim form or a site report form (if applicable)

150 Residential, Commercial and Industrial

6.7.3 we will pay to return the repaired or replaced goods to you if the address is within

Great Britain

6.7.4 you must ensure that the returned goods shall be free of external equipment and that any openings are effectively sealed against ingress of foreign matter

6.7.5 if you are returning compressors you must ensure that they are fitted with the appropriate electrical equipment and

6.7.6 you must return the goods to us within 21 days of the fault occurring.

6.8 Where goods are returned to us for repair not under manufacturer warranty:

6.8.1 The price quoted for the repair excludes VAT (unless otherwise stated). VAT will be charged at the rate applying at the time of the return of your repaired goods to you.

6.8.2 Our quotations for repair lapse after 30 days (unless otherwise stated).

6.8.3 The price quoted for repair excludes delivery of the goods to us and excludes delivery of the repaired goods back to you (unless otherwise stated)

6.8.4 We will inform you if the goods are unrepairable. If you have not requested that the unrepeatable goods be returned to you, you agree we can dispose of the goods

(without any liability to you) on 28 days written notice.

6.8.5 We will charge an inspection fee but will normally waive the fee if you instruct us to repair the goods in accordance with our quotation.

6.9 We cannot accept liability in respect of any defect arising from fair wear and tear, wilful damage, misuse, abnormal working conditions, failure to follow our instructions or the guidelines for maintenance provided by us or the manufacturer, or the alteration or repair of the goods without our or the manufacturers approval.

6.10 We are not liable for any other loss or damage arising from the contract or the supply of goods or their use, even if we are negligent, including (as examples only)

6.10.1 direct financial loss, loss of profits or loss of use And

6.10.2 indirect or consequential loss

6.11 Our total liability to you (from one single cause) for damage to property caused by our negligence is limited to £750,000.

6.12 For all other liabilities not referred to elsewhere in these terms our liability is limited in damages to the price of the goods.

6.13 Nothing in these terms restricts or limits our liability for death or personal injury resulting from negligence.

6.14 The warranty is not transferable.

7 Specification

7.1 If we prepare the goods in accordance with your specifications or instructions you must ensure that:

7.1.1 the specifications or instructions are accurate

7.1.2 goods prepared in accordance with those specifications or instructions will be fit for the purpose for which you intend to use them and

7.1.3 your specifications or instructions will not result in the infringement of any intellectual property rights of a third party, or in the breach of any applicable law or regulation.

7.2 We reserve the right

7.2.1 to make any changes in the specifications of our goods that are necessary to ensure they conform to any applicable safety or statutory requirements and

7.2.2 to make without notice any minor modifications in our specifications we think necessary or desirable.

8 Return of goods

8.1 We will accept the return of goods from you only:

8.1.1 by prior arrangement (confirmed in writing)

8.1.2 on payment of an agreed handling charge (unless the goods were defective when delivered) and

8.1.3 where the goods and packaging are as fit for sale on their return as they were on delivery.

9 Export terms

9.1 Clause 9 of these terms applies (except to the extent that it is inconsistent with any written agreement between us) where we supply the goods over an international border or overseas.

9.2 The Incoterms of the International Chamber of Commerce which are in force at the time when the contract is made apply to exports, but these terms prevail over the

Incoterms to the extent that there is any inconsistency.

9.3 Unless otherwise agreed, the goods are supplied ex works our place of business.

9.4 Where the goods are to be sent by us to you by a route including sea transport we are under no obligation to give a notice under section 32(3) of the Sale of Goods

Act 1979.

9.5 You are responsible for arranging testing and inspection of the goods at our premises before shipment (unless otherwise agreed). We are not liable for any defect in the goods which would be apparent on inspection unless a claim is made before shipment. We are not liable for any damage during transit.

9.6 We are not liable for death or personal injury arising from the use of the goods delivered in the territory of another State (within the meaning of s.26 (3) (b) Unfair

Contract Terms Act 1977).

10 Cancellation

10.1 You may not cancel the order unless we agree in writing (and clauses 2.2.2 and

10.2 then apply).

10.2 If the order is cancelled (for any reason) you are then to pay us for all stock (finished or unfinished) that we may then hold (or to which we are committed) for the order.

10.3 We may suspend or cancel the order, by written notice if:

10.3.1 you fail to pay us any money when due (under the order or otherwise)

10.3.2 you become insolvent

10.3.3 you fail to honour your obligations under these terms.

11 Waiver and variations

11.1 Any waiver or variation of these terms is binding in honour only unless:

11.1.1 made (or recorded) in writing

11.1.2 Signed on behalf of each party and

11.1.3 expressly stating an intention to vary these terms.

11.2 All orders that you place with us will be on these terms (or any that we may issue to replace them). By placing an order with us, you are expressly waiving any printed terms you may have to the extent that they are inconsistent with our terms.

12 Force majeure

12.1 If we are unable to perform our obligations to you (or able to perform them only at unreasonable cost) because of circumstances beyond our control, we may cancel or suspend any of our obligations to you, without liability.

12.2 Examples of those circumstances include act of God, accident, explosion, war, terrorism, fire, flood, transport delays, strikes and other industrial disputes and difficulty in obtaining supplies.

13 General

13.1 English law is applicable to any contract made under these terms.

13.2 The English and Welsh courts have non exclusive jurisdiction.

13.3 If you are more than one person, each of you is liable for all of your obligations under these terms (joint and several liability).

13.4 If any of these terms are unenforceable as drafted:

13.4.1 it will not affect the enforceability of any other of these terms and

13.4.2 if it would be enforceable if amended, it will be treated as so amended.

13.5 We may treat you as insolvent if:

13.5.1 you are unable to pay your debts as they fall due or

13.5.2 you (or any item of your property) becomes the subject of: a. any formal insolvency procedure (examples of which include receivership, liquidation, administration, voluntary arrangements (including a moratorium) or bankruptcy) b. any application or proposal for any formal insolvency procedure or c. any application, procedure or proposal overseas with similar effect or purpose.

13.6 All brochures, catalogues, technical literature and other promotional materials are to be treated as illustrative only. Their contents form no part of any contract between us and you should not rely on them in entering into any contract with us.

13.7 Any notice by either of us which is to be served under these terms may be served by leaving it at or by delivering it to (by first class post or by fax) the others registered office or principal place of business. All such notices must be signed.

13.8 No contract will create any right enforceable (by virtue of the Contracts (Rights of

Third Parties) Act 1999) by any person not identified as the buyer or seller.

13.9 The only statements upon which you may rely in making the contract with us are those made in writing by someone who is (or whom you reasonably believe to be) our authorised representative and either:

13.9.1 are contained in our estimate (or any covering letter) and not withdrawn before the contract is made or

13.9.2 expressly state that you may rely on them when entering into the contract.

13.10 Nothing in these terms affects or limits our liability for fraudulent.

Price List 2015 151

Notes

152 Residential, Commercial and Industrial

Conditions

Capacity Conditions

Unit cooling and heating capacities shown within this price list are based on the following conditions:

Nominal cooling

Ambient = 35°C

Internal = 27°C db 19°C wb

Nominal heating

Ambient = 7°C db 6°C wb

Internal = 20°C db

UK cooling

Ambient = 30°C

Internal = 22°C db 16°C wb

Heat Source

Unless otherwise indicated, all units within this price list are air-cooled.

Seasonal Efficiency

Split and Sky Air

Systems of up to 12kW must now show Seasonal

Efficiency Ratings instead of Nominal Efficiency Ratings.

These ratings (SEER for cooling, SCOP for heating) represent how effective a system is throughout the year, and are in accordance with EN14825.

For more information on Seasonal Efficiency, visit www.daikin.co.uk/seasonal-efficiency

For Daikin UK, this means all our Split and Sky Air products up to 12kW display SEER and SCOP data along with Energy Label information and Annual Energy

Consumption of the system. The AEC is based upon

500 hours use per year.

VRV (ESEER)

ESEER is defined as the European Seasonal Energy

Efficiency Ratio and is a measure of the performance of the outdoor unit only.

Nominal Efficiency

This measure of efficiency is calculated by dividing the capacity output of a unit by the power required to deliver it.

For cooling, this is expressed as EER, for heating as COP.

Nominal efficiencies are used for systems above 12kW.

It is not possible to compare nominal and Seasonal

Efficiency ratings.

Daikin

Air Conditioning Guide

Issue 1

Need it?

Have it

Acton (London)

0208 896 9187

Edinburgh

01506 855 306

Bow (London)

0208 525 9888

Exeter

01392 823 992

Bristol

0117 977 2616

High Wycombe

01494 473 330

Birmingham

0121 328 1122

Hull

01482 974 500

Chelmsford

01245 463 539

Kent

01322 529 994

Dorset

01292 824 186

Nottingham

0115 986 6477

Daikin Air Conditioning

Suppliers

Refreshingly Different www.rw-wholesale.co.uk

Daikin Air Conditioning

Suppliers

Refreshingly Different www.rw-wholesale.co.uk

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement