Cover E-Series Steam Generator & Fluid Heater Installation Manual CLAYTON INDUSTRIES City Of Industry, California USA R016600V 04-2015 WARRANTY Clayton warrants its equipment to be free from defects in material and/or workmanship for a period of 1 year from date of original installation, or 15 months from date of shipment from the factory, whichever is shorter. Upon expiration of such warranty period, all liability of Clayton shall immediately cease. During the warranty period if the Clayton product is subjected to improper installation, misuse, negligence, alteration, accident, improper repair, or operated contrary to Clayton’s printed instructions; all liability of Clayton shall immediately cease. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, EXCEPT TITLE AND DESCRIPTION, WHETHER WRITTEN, ORAL OR IMPLIED, AND CLAYTON MAKES NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR PURPOSE. No representative of Clayton has any authority to waive, alter, vary, or add to the terms hereof without prior approval in writing executed by two officers of Clayton Industries. If within the period of such warranty the purchaser promptly notifies Clayton’s Service Department (Attention: Warranty Repairs, Cincinnati, OH) in writing of any claimed defect; and if requested by Clayton, promptly returns the part(s) claimed defective to Clayton’s manufacturing facility with all transportation charges prepaid to Clayton, Clayton will consider said part(s) covered under this warranty. All parts returned must be shipped to Clayton’s Cincinnati, OH facility (Attention: Warranty Repairs, Cincinnati, OH) except coils which must be shipped to Clayton’s City of Industry, CA facility (Attention: Warranty Repairs, City of Industry, CA). Once reviewed by Clayton, if it appears to Clayton that such part(s) is defective in material and/ or workmanship, Clayton will at its sole discretion & choice repair such defective part(s), or replace same with like or similar part(s), or provide a credit for the part(s). The purchaser shall be responsible for all transportation and labor charges relating to installation of any replacement part or removal of a defective part. It is expressly understood that the repair or replacement of such defective part(s) by Clayton shall constitute the sole remedy of purchaser and sole liability of Clayton whether on warranty, contract, or negligence; and that Clayton shall not be liable for any other expense, injury, loss, or damage whether direct, incidental, or consequential. With respect to any non-Clayton part(s) supplied hereunder; other than the duration of the warranty, the OEM manufacturer’s warranty shall apply and be exclusive. Goods sold or delivered may, at Clayton’s discretion, consist in part of reconditioned or reassembled parts which have been inspected and checked by Clayton and which are fully covered by such warranty as if new. In performing its warranty as obligations hereunder, Clayton may in its discretion repair or replace any part with such a reconditioned or reassembled part. Clayton Service Branches U.S. & CANADA FACTORY DIRECT SERVICE BRANCHES ATLANTA 125-A Howell Road, Tyrone, GA 30290 (770) 632-9790 CANADA 13 Edvac Drive, Unit 18, Brampton, ON L6S5W6 (905) 791-3322 CHICAGO 37 Sherwood Terrace Unit 110, Lake Bluff, IL 60044 (847) 295-1007 CINCINNATI 3051 Exon Avenue, Cincinnati, OH 45241 (513) 563-1300 CLEVELAND 9241 Ravenna Road Suite C2, Twinsburg, OH 44087 (330) 425-8006 DALLAS 719 Ashford Lane, Wylie, TX 75098 (972) 224-5011 DETROIT 37648 Hills Tech Drive, Farmington Hills, MI 48331 (248) 553-0044 KANSAS CITY 1600 Genessee Suite 524, Kansas City, MO 64102 (816) 221-2411 LOS ANGELES 17477 Hurley Street, City of Industry, CA 91744 (626) 435-1200 NEW ENGLAND 387 Page Street, Unit 11A, Stoughton, MA 02072 (781) 341-2801 NEW JERSEY 10 South River Road Suite 6, Cranbury, NJ 08512 (609) 409-9400 NORTHERN CALIFORNIA P.O. Box 1956, Bethel Island, CA 94511 (510) 782-0283 Title Page Steam Generator and Fluid Heater Installation Manual CLAYTON INDUSTRIES 17477 Hurley Street City of Industry, CA 91744-5106 USA Phone: +1 (626) 435-1200 FAX: +1 (626) 435-0180 Internet: www.claytonindustries.com Email: [email protected] © Copyright 2004, 2006, 2008, 2010, 2012, 2013 Clayton Industries. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means (electronic, mechanical, photocopy, recording, or otherwise) without written permission from Clayton Industries. The descriptions and specifications shown were in effect at the time this publication was approved for printing. Clayton Industries, whose policy is one of continuous improvement, reserves the right to discontinue models at any time, or change specifications or design without notice and without incurring any obligation. FACTORY DIRECT SALES AND SERVICE UNITED STATES OFFICES ATLANTA • CHICAGO • CINCINNATI • CLEVELAND • DALLAS • DETROIT KANSAS CITY • LOS ANGELES • NEW ENGLAND • NEW JERSEY NORTHERN CALIFORNIA LICENSEES, AFFILIATES, SALES and SERVICE DISTRIBUTORS WORLDWIDE Table of Contents Section 1 Introduction ................................................................................................................ 1-1 Section 2 General Information .................................................................................................. 2-1 2.1 2.2 Location .............................................................................................................. 2-1 Positioning and Anchoring Equipment .............................................................. 2-2 2.2.1 General Installation Requirements ............................................................. 2-2 2.2.2 Equipment Anchoring ................................................................................ 2-3 2.2.3 Grouting ..................................................................................................... 2-3 2.2.4 Clayton PD Feedwater Pump Placement ................................................... 2-4 2.3 Combustion Air .................................................................................................. 2-4 2.4 Customer Connections - Steam Generator ......................................................... 2-5 2.5 Exhaust Stack Installation .................................................................................. 2-5 2.5.1 Installing Exhaust Stacks ........................................................................... 2-6 2.5.2 Installing Exhaust Stacks With External Condensing Economizer ......... 2-11 2.6 Piping ............................................................................................................... 2-13 2.6.1 General ..................................................................................................... 2-13 2.6.2 Systems .................................................................................................... 2-13 2.6.3 Atmospheric Test Valve ........................................................................... 2-15 2.6.4 Steam Header and Steam Sample Points ................................................. 2-15 2.7 Feedwater Treatment ........................................................................................ 2-15 2.7.1 Water Softeners ........................................................................................ 2-16 2.7.2 Make-up Water Line Sizing ..................................................................... 2-16 2.8 Feedwater Supply Requirements ...................................................................... 2-17 2.8.1 Multi-unit Systems ................................................................................... 2-17 2.8.2 Velocity Requirements and Calculation ................................................... 2-18 2.8.3 Acceleration Head (Ha) Requirements .................................................... 2-21 2.9 Flexible Feedwater Hose Connection And Connection Sizing ........................ 2-21 2.9.1 Supply Side Connections ......................................................................... 2-22 2.9.2 Discharge Side Connections .................................................................... 2-22 2.10 Pump Suction and Discharge Piping System Design ....................................... 2-22 2.10.1 General Layout Guidelines ...................................................................... 2-22 2.10.2 Pipe Sizing Guidelines ............................................................................. 2-23 2.11 Net Positive Suction Head (NPSH) .................................................................. 2-24 2.11.1 NPSHA .................................................................................................... 2-25 2.11.2 NPSHR ..................................................................................................... 2-25 iii 2.11.3 Acceleration Head (Ha) ........................................................................... 2-26 2.12 General Installation Concerns .......................................................................... 2-28 2.12.1 Charge Pumps .......................................................................................... 2-28 2.12.2 Charge Pumps Are Not A Substitute ....................................................... 2-28 2.12.3 Multiple Pump Hookup ........................................................................... 2-28 2.12.4 Pumphead Cooling Water System (Clayton Feedwater Pumps) .............. 2-28 2.13 Electrical ........................................................................................................... 2-28 2.14 Electrical Grounding ........................................................................................ 2-29 Section 3 Clayton Feedwater Pumps and Water Systems ...................................................... 3-1 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 General ............................................................................................................... 3-1 Skid Packages ..................................................................................................... 3-1 Customer Connections ....................................................................................... 3-3 Open System ...................................................................................................... 3-3 Deaerator (D/A) .................................................................................................. 3-5 Semi-closed Receiver (SCR) .............................................................................. 3-8 Semi-closed Receiver Skids ............................................................................... 3-8 Head Tank .......................................................................................................... 3-8 Section 4 Fuel System ................................................................................................................. 4-1 4.1 4.2 4.3 General ............................................................................................................... 4-1 Natural Gas ......................................................................................................... 4-1 Oil ....................................................................................................................... 4-2 4.3.1 General ....................................................................................................... 4-2 4.3.2 Light Oil ..................................................................................................... 4-2 4.3.3 Heavy Oil ................................................................................................... 4-3 Section 5 Trap Separators ......................................................................................................... 5-1 5.1 5.2 5.3 General ............................................................................................................... 5-1 Operation ............................................................................................................ 5-1 Installation .......................................................................................................... 5-2 5.3.1 General ....................................................................................................... 5-2 5.3.2 Trap Separator Vent ................................................................................... 5-2 5.3.3 Feedwater Receiver Supply Lines ............................................................. 5-2 Section 6 Technical Specifications ............................................................................................. 6-1 6.1 6.2 6.3 6.4 General ............................................................................................................... 6-1 Agency Approvals .............................................................................................. 6-1 Construction Materials ....................................................................................... 6-1 Flame Safeguard ................................................................................................. 6-1 iv 6.5 Safety Controls ................................................................................................... 6-2 6.5.1 Temperature Control Devices .................................................................... 6-2 6.5.2 Regulator Approvals .................................................................................. 6-2 6.5.3 Steam Limit Pressure Switch ..................................................................... 6-2 6.5.4 Combustion Air Pressure Switch ............................................................... 6-2 6.5.5 Atomizing Oil Nozzles .............................................................................. 6-2 6.5.6 Pump Oil Level Switch .............................................................................. 6-2 6.5.7 Overcurrent Protection ............................................................................... 6-2 6.6 Equipment Specifications ................................................................................... 6-2 6.6.1 Modulating Generators .............................................................................. 6-3 6.6.2 Table 6-1 Supplemental Information ......................................................... 6-4 6.7 Equipment Layout And Dimensions .................................................................. 6-4 6.7.1 Modulating Steam Generators ................................................................... 6-5 6.7.2 Condensate Receiver Tanks ..................................................................... 6-18 6.7.3 Blowdown Tanks ..................................................................................... 6-19 Section 7 Optional Equipment .................................................................................................. 7-1 7.1 7.2 Booster Pump(s) ................................................................................................. 7-1 Blowdown System .............................................................................................. 7-1 7.2.1 Blowdown Tank ......................................................................................... 7-1 7.2.2 Automatic TDS Controller ......................................................................... 7-2 7.2.3 Continuous Blowdown Valve .................................................................... 7-2 7.3 Valve Option Kit ................................................................................................. 7-2 7.4 Soot Blower Assembly ....................................................................................... 7-2 7.5 Pressure Regulating Valves (BPR/PRV) ............................................................ 7-2 7.5.1 Back Pressure Regulators .......................................................................... 7-2 7.5.2 Pressure Regulating Valves ........................................................................ 7-3 Supplement I - SCR ......................................................................................................................I-1 1.1 Semi-Closed Receiver Systems (SCR) ............................................................... I-1 1.1.1 Requirements .............................................................................................. I-1 1.1.2 Components of an SCR System refer to Drawing R-16596 ....................... I-1 1.1.3 Water Level Gauge Glass ............................................................................I-1 1.1.4 Steam Trap .................................................................................................. I-1 1.1.5 Vent ............................................................................................................. I-2 1.1.6 Level Control .............................................................................................. I-2 1.1.7 Steam Relief Valve ...................................................................................... I-2 1.1.8 Sparger Tube ............................................................................................... I-2 1.1.9 Back Pressure Regulator .............................................................................I-2 1.1.10 Pressure Reducing Valve ............................................................................I-2 v 1.1.11 1.1.12 1.1.13 1.1.14 1.1.15 1.1.16 Make-up Tank ............................................................................................. I-3 SCR Transfer Pump .................................................................................... I-3 Chemical Treatment .................................................................................... I-3 Hook-up ...................................................................................................... I-3 System Steam Traps .................................................................................... I-3 A General Statement ................................................................................... I-4 Supplement II - Heavy Oil ......................................................................................................... II-5 2.1 Heavy Fuel Oil (Models E-154 To E-504) .........................................................II-5 2.1.1 General Statement ......................................................................................II-5 2.1.2 Storage Tanks .............................................................................................II-5 2.1.3 Transfer Pump ............................................................................................II-5 2.1.4 Supply and Return Lines ............................................................................II-6 2.1.5 Oil Preheating Equipment (See Heavy Oil System Flow Diagram) ..........II-6 2.1.6 Electric Immersion Heater Option .............................................................II-6 2.1.7 Steam Coil Heater ......................................................................................II-6 2.1.8 Exhaust Stack .............................................................................................II-7 2.2 Fuels ...................................................................................................................II-9 2.3 Clayton Steam Generators Equipped With Heavy Oil Fuel System ................II-10 2.3 Heavy Oil Fuel Specifications .................................................................II-10 2.3 Light Fuel Oil Specifications ...................................................................II-10 Supplement III - Fluid Heater ................................................................................................III-13 3.1 Fluid Heaters .................................................................................................. III-13 Appendix A - Steam Generator Lifting Instructions ........................................................ A-1 Appendix B - Saturated Steam P-T Table ........................................................................... B-5 Appendix C - Piping and Instrumentation Diagrams ...................................................... C-7 Appendix D - Installing SE Option .................................................................................. D-21 vi SECTION I - INTRODUCTION The CLAYTON STEAM GENERATOR is manufactured in accordance with the American Society of Mechanical Engineers (ASME) Boiler Pressure Vessel Code (BPVC), Section I. Construction and inspection procedures are regularly monitored by the ASME certification team and by the Authorized Inspector (AI) commissioned by the Jurisdiction and the National Board of Pressure Vessel Inspectors (NBBI). The NBBI is a nonprofit organization responsible for monitoring the enforcement of the various sections of the ASME Code. Its members are the chief boiler and pressure vessel inspectors responsible for administering the boiler and pressure vessel safety laws of their jurisdiction. The electrical and combustion safeguards on each CLAYTON STEAM GENERATOR are selected, installed, and tested in accordance with the standards of the Underwriters’ Laboratories and such other agency requirements as specified in the customer’s purchase order. NOTE It is important that the steam generator(s)/fluid heaters and its accessories be installed in accordance with ASME/ANSI Codes, as well as, all applicable Federal, State, and local laws, regulations and codes. NOTE Clayton sales representatives and service technicians ARE NOT authorized to approve plant installation designs, layouts, or materials of construction. If Clayton consultation or participation in plant installation design is desired, please have your local Clayton sales representative contact Clayton corporate headquarters for more information and pricing. 04/22/2015 1-1 Sect01_e.fm STEAM GENERATOR & FLUID HEATER INSTALLATION MANUAL (This page intentionally left blank.) Sect01_e.fm 1-2 04/22/2015 SECTION II - GENERAL INFORMATION 2.1 Location Give careful consideration to your Clayton equipment investment and the equipment warranty when selecting an installation location. The equipment should be located within close proximity to necessary utilities, such as fuel, water, electricity, and ventilation. General consumption data for each model is provided in Table 1 of Section VI. General equipment layout and dimensions are provided in Table 2 of Section VI. For actual dimensions and consumption information, please refer to the data submitted with each specific order. NOTE Clayton’s standard equipment is intended for indoor use only. Clayton’s equipment must be protected from weather at all times. The steam generator/fluid heater, and any associated water and chemical treatment equipment must be maintained at a temperature above 45o F (7o C) at all times. Maintain adequate clearance around your Clayton equipment for servicing needs. Maintain a minimum clearance of 60 inches (1.5 m) in front of the equipment, a minimum clearance of 36 inches (1 m) to the left and right sides, and a minimum clearance of 18 inches (0.5 m) to the rear of the equipment. Ample overhead clearance, including clearance for lifting equipment, should be considered in case the coil requires removing. Equipment layout and dimensions are provided in Table 2 of Section VI. Review the Plan Installation drawing supplied with the order for specific dimensions and clearance information. CAUTION ALL combustible materials must be kept a minimum of 48 inches (1.2 m) from the front and 18 inches (0.5 m) from the top, rear, and sides of the equipment. A minimum clearance of 18 inches (0.5 m) must also be maintained around the flue pipe. Flooring shall be non-combustible. This equipment must not be installed in an area susceptible to corrosive or combustible vapors. 04/21/2015 2-1 Sect02_Genrl-xx4_s.fm Steam Generator & Fluid Heater Installation Manual IMPORTANT KEEP CLAYTON EQUIPMENT CLEAR OF ALL OBSTRUCTIONS. DO NOT ROUTE ANY NON-CLAYTON PIPING, ELECTRICAL CONDUIT, WIRING, OR APPARATUS INTO, THROUGH, OR UNDER CLAYTON EQUIPMENT. ANY OBSTRUCTIONS CREATED BY SUCH NON-CLAYTON APPARATUS WILL VERY LIKELY INTERFERE WITH THE PROPER OPERATION AND SERVICING OF THE EQUIPMENT. ALL SUCH INTERFERENCE IS THE SOLE RESPOSIBILITY OF THE CUSTOMER. CLAYTON’S PLAN INSTALLATION DRAWINGS, INCLUDING JOB-SPECIFIC DRAWINGS, ARE FOR VISUAL REFERENCE ONLY. 2.2 Positioning and Anchoring Equipment 2.2.1 General Installation Requirements Lifting instructions are provided in Appendix A. Proper rigging practices and equipment must be applied when lifting this equipment. Forklifts with roll bars can be used for installations with overhead space limitations. WARNING DO NOT attach rigging gear to the top coil lifting hook or any part of this equipment other than the main frame. When used, mounting legs with fasteners are provided. All legs and fasteners must be attached. DO NOT alter the lengths of the mounting legs without first consulting Clayton. The mounting legs are designed to provide adequate space and accessibility for servicing the equipment. Proper floor drains must be provided under the generator(s). MAKE SURE ALL EQUIPMENT IS LEVELED AND ALL ANCHORING POINTS ARE USED. Level the equipment using full-size, stainless steel, slotted shims that match the equipment pads designed and provided on the equipment. Clayton recommends full-size slotted shims. If slotted machine shims are used, Clayton requires C-size or larger for pump skids and E-size for generator and water skids. Use full-sized anchors to anchor the equipment. Make sure anchors are strong enough to withstand operating, wind, and seismic loads that exists in the installation location. To enhance serviceability and accommodate service personnel, Clayton recommends placing its generators, main positive displacement (PD) feedwater pumps, feedwater skids, and water treatment skids on 4– 6 inch (10–15 cm) high equipment maintenance pads. These equipment maintenance pads on which the equipment will be installed must be 3–6 inches (8–15 cm) wider and longer than the equipment base plates. Make sure the equipment maintenance pads are properly reinforced and leveled. Fully grout into place all generators, pumps, and skids, after leveling and anchoring, to provide adequate support and minimize equipment vibration. Grouting is important, but it does not replace the use of metal shims under each anchor bolt location. Every anchor hole location on the equipment skid(s) requires an anchor bolt. Sect02_Genrl-xx4_s.fm 2-2 04/21/2015 Section II - General Information It is recommended the mass of the concrete foundation be sufficient to absorb the dynamic and static forces from the operation, wind, or seismic conditions that exist at the specific equipment installation location. Accepted concrete construction guidelines, for equipment installation, recommends that the concrete foundation be at least 5 1/2” to 7 1/2” (14 cm to 19 cm) thick, depending on soil, underground water, environmental, and seismic conditions. If Clayton’s generator, pump, or skid are mounted on a surface other than a concrete foundation, such as a steel structure, then the equipment base frame must be supported on rigid steel beams that are aligned along the length of the equipment base frame. It is strongly recommended that Clayton’s equipment be supported with horizontal and vertical main structural members at all its equipment anchor pads. Perform stress calculations for the steel structure to confirm it has adequate rigidity to minimize baseplate distortion and vibration during operation. Clayton rec1/2 in. ommends incorporating vibration isolation on this type (1.5 cm) of installation. NUT 2.2.2 WASHER SET Equipment Anchoring To properly secure the equipment base frames to the equipment maintenance pads and foundation, proper anchor bolts are required. The anchor bolt diameter must be fully sized to the anchor bolt holes in Clayton’s equipment base frame. For required bolt sizes, see the plan installation drawings for the specific Clayton equipment. The anchor bolt length extending above the foundation should equal the total height of all shimming and leveling devices, 3/4–1 1/2 inch (2–4 cm) grout filler for leveling, the equipment base frame thickness, washer set, anchor bolt nut, and an additional 1/2 inch (1.5 cm) above anchor bolt nut (See Figure 2-1.). The proper anchor bolt length and its embedded depth must meet all static and dynamic loading from the operation of the equipment, wind loading, and seismic loading. EQUIPMENT BASE FRAME *SHIM/LEVELING GROUT FILLER FOUNDATION EQUIPMENT MAINTENANCE PAD ANCHOR BOLT * SHIMS MUST BE C-SIZE, OR LARGER, FOR PUMP SKIDS AND E-SIZE, OR LARGER, FOR GENERATOR AND WATER SKID FRAMES. Figure 2-1 Anchor bolt installation CAUTION Failure to adequately support Clayton’s equipment can lead to excessive vibration, which is detrimental to Clayton’s product and component life cycle, especially electrical components. 2.2.3 Grouting Make sure to grout the entire equipment base frame before making any additional connections to your Clayton equipment. Grouting the equipment base frame to the foundation provides a good and sturdy union between them. Grout is a concrete-type material that is used to fill the gap between the equipment base frame and the foundation. The grout increases the mass of the base to help reduce equipment vibration, 04/21/2015 2-3 Sect02_Genrl-xx4_s.fm Steam Generator & Fluid Heater Installation Manual which is fundamental to product life. In addition, the grout will fill any voids or imperfections in the foundation surface to increase proper equipment support. When the grout hardens, the equipment base frame and the foundation becomes one solid unit to support the equipment. 2.2.4 Clayton PD Feedwater Pump Placement Clayton’s PD pump placement and its relative position to Clayton’s generator is critical for managing pump-induced equipment vibration; therefore, this helps to extend equipment and component life. Substantial hydraulic vibration can develop when pipe runs between the PD feedwater pump(s) and the heating coil inlet are lengthened and/or elevated without additional piping design and component changes. IMPORTANT To prevent voiding Clayton’s equipment warranty, it is required that any intended relocation of Clayton’s PD feedwater pump from the generator be pre-approved by Clayton’s engineering group prior the equipment installation design. DO NOT MOVE OR RELOCATE THE POSITION OF CLAYTON’S MAIN PD FEEDWATER PUMP, RELATIVE TO THE GENERATOR, AS SHOWN ON CLAYTON’S PLAN INSTALLATION DRAWING, WITHOUT FIRST CONSULTING WITH CLAYTON’S ENGINEERING GROUP. Clayton’s service team is restricted from commissioning or starting any Clayton equipment where the main PD feedwater pump(s) has been relocated without prior approval. 2.3 Combustion Air A sufficient volume of air must be continuously supplied to the boiler room to maintain proper combustion. Boiler room fresh air vents must be sized to maintain air velocity less than 500 sf/m with less than 1/4 inch water pressure drop. Ventilation openings must be sized at 3 ft2/100 bhp or larger. As a guideline, there should be 12 cfm of air per boiler horsepower.1 This will provide sufficient air for combustion and outer shell cooling. Refer to Table 6.1A and 6.1B of Section VI for the required area of free air intake. An inlet air duct should be used when there is insufficient boiler room air, when the boiler room air supply is contaminated with airborn material or corrosive vapors, and when noise consideration is required. A suitable inlet weather shroud is required and an air filter should be installed when there is a potential for airborn contaminates. Air inlet filters capable of filtering airborn contaminates down to 3 microns are required for FMB equipped units. If an inlet air duct is used in cold weather climates, it must contain a motor operated damper with a position interlock switch to prevent freezing of the heating coil. The maximum allowable pressure drop in the inlet air duct system is 0.5 inch water column. 1 This guideline is based on an installation at about sea level; high altitude installations require more air. Sect02_Genrl-xx4_s.fm 2-4 04/21/2015 Section II - General Information 2.4 Customer Connections - Steam Generator The number, type, and size of required customer connections will vary with equipment size and type of skid package provided. Table 2-1 below identifies the required steam generator customer connections for the various skid packages. The equipment connections and sizes are provided in Tables 6-2 through 6-6 in Section VI. Additional customer connection tables located in Section III provide detailed descriptions of connections for Clayton water treatment packages. Steam generator installation guidelines are provided in the following sections. Water treatment component installation guidelines are provided in Section III. Table 2-1: Customer Connections EQUIPMENT PACKAGES STEAM GENERATORS WITH Required Customer Connections Include: Steam Generator only Feedwater Receiver Water Skid Generator Skid Exhaust Stack X X X X Separator Steam Outlet X X X X Safety Relief Valves Discharge X X X X Feedwater Inlet X X X Coil Drain(s) X X X Separator Drain X X X Steam Trap(s) Outlet X X X Fuel Inlet X X X X Fuel Return (Oil Only) X X X X Atomizing Air Inlet (Oil Only) X X X X Electrical Connection-Primary X X X X Electrical-Generator Skid Interconnect X X Coil Gravity Drain X X X X Fuel Pump Relief Valve (Oil Only) X X X X 2.5 Exhaust Stack Installation (See Figures 2-2, 2-3, 2-4, 2-5, and 2-6.) 04/21/2015 2-5 Sect02_Genrl-xx4_s.fm Steam Generator & Fluid Heater Installation Manual 2.5.1 Installing Exhaust Stacks Clayton strongly recommends a barometric damper on all installations. Proper installation of the exhaust stack is essential to the proper operation of the Clayton steam generator. Clayton specified allowable back-pressure of 0.0 to -0.25 w.c.i. must be considered when designing and installing the exhaust stack. The stack installer is responsible for conforming to the stack draft back-pressure requirements. Ninety-degree elbows should be avoided. Forty-five degree elbows should be used when the stack cannot be extended straight up. Stacks in excess of 20 feet (6 meter) may require a barometric damper. Stacks for all low NOx generators require a barometric damper. The material and thickness of the exhaust stack must comply with local code requirements, and be determined based on environmental and operating conditions (exposure to the elements, humidity, constituents of fuel, etc.). The area of free air space between the exhaust stack and building, roof, or flashings must also comply with local codes. The material used for roof flashings must be rated at a minimum of 600o F (315o C). A “weather cap” must be installed on top of the exhaust stack. IMPORTANT The specified exhaust stack connection size (shown in Tables 6-2 through 6-5, in Section VI, and in Clayton’s Plan Installation Drawings) is the minimum required for Clayton’s equipment. It is NOT indicative of the required stack size to meet installation requirements or by local codes. All exhaust stack installations must be sized to meet prevailing codes, company and agency standards, and local conditions, as well as, the recommended requirements specified above. NOTE Clayton recommends all generators purchased with our integral economizers be installed with stainless steel, insulated, double-walled exhaust stacks. All units operating on light or heavy oil should use stacks constructed with stainless steel. Clayton recommends all heavy oil units use a free-standing, vertical stack, with clean-out access, as shown in Figure 2-4 NOTE All oil-fired units must have an exhaust gas temperature indicator installed in the stack. A removable spool piece must be installed at the generator flue outlet to facilitate removal and inspection of the heating coil. To permit sufficient vertical lift, the spool piece should be at least 4 feet (1.2 m) tall. The spool installation should be coordinated with the customer supplied rigging. If operating on any type of fuel oil, an access door must be provided immediately at the generator flue outlet (first vertical section) to provide a means for periodic water washing of the heating coil. The section of the stack located inside the building should be insulated to reduce heat radiation and noise. Sect02_Genrl-xx4_s.fm 2-6 04/21/2015 Section II - General Information Exhaust stacks are to be self-supporting (maximum stack connection load is 50 lbs. {22 kg}) and must extend well above the roof or building, (refer to local building codes). If nearby structures are higher than the building housing the steam generator(s), the stack height should be increased to clear these structures. NOTE It is strongly recommended that a back draft damper (full size and motor operated with position interlock switch) be installed to prevent freeze damage to the heating coil. Machine installations, in cold weather zones, that plan to lay the machine up wet and may encounter freezing conditions must install an air-tight back draft damper in the exhaust stack to prevent down-draft freezing. Clayton recommends insulating all exhaust stacks to maintain gas temperatures above dew point. Special consideration should be given to installations in and around residential areas. Depending on the design, some noise and harmonic vibration may emanate from the exhaust stack. The noise/harmonics may bounce off surrounding structures and be offensive to employees and neighbors. If this condition occurs, a stack muffler is recommended. In-line stack mufflers are typically used, installed vertically and above roof level. They may be installed horizontally or closer to the equipment. See Figures 2-2, 2-3, and 2-4 for stack configurations. 04/21/2015 2-7 Sect02_Genrl-xx4_s.fm Steam Generator & Fluid Heater Installation Manual NOTE 1: Barometric dampers are recommended on all installations with stack heights over 20 feet (6 meters) and on any low NOx units. NOTE 2: A removable, 4 feet (1.2 meters) minimum, stack section is recommended to facilitate steam generator/fluid heater maintenance and repair. NOTE 3: A backdraft damper must be installed in the exhaust stack for installations in cold weather climates. All backdraft dampers must be air-tight and proof-of-position switches. NOTE 4: Oil-fired units require a 2W x 3H feet (0.6W x 0.9H meter) access portal in the stack for inspection and water washing. A floor drain is required at the bottom of the generator under or close to the burner opening. Figure 2-2 Standard exhaust stack layout for natural gas and light-oil installations only. Not recommended for heavy-oil machines. Sect02_Genrl-xx4_s.fm 2-8 04/21/2015 Section II - General Information * See Notes 1 – 4 in Figure 2-2. Figure 2-3 Alternate multi-unit exhaust stack layout for natural gas and light-oil installations only. Not recommended for heavy-oil units. 04/21/2015 2-9 Sect02_Genrl-xx4_s.fm Steam Generator & Fluid Heater Installation Manual * See Notes 1 – 4 in Figure 2-2. NOTE: Exhaust stacks connecting to a common main stack must be offset from each other. Figure 2-4 Recommended heavy-oil exhaust stack layout for single or multi-unit installations. Sect02_Genrl-xx4_s.fm 2-10 04/21/2015 04/21/2015 2-11 NOTE 4: It is recommended that all stack sections be manufactured from 316L stainless steel NOTE 3: An air-tight backdraft (shutoff) damper must be installed in the exhaust stack for installations in cold weather climates. 2.5.2 NOTE 2: A removable, 4 feet (1.2 meters) minimum, stack section is recommended to facilitate steam generator/fluid heater maintenance and repair. NOTE 1: Barometric dampers are recommended on all installations with stack heights over 20 feet (6 meters) and required on low NOx units. Section II - General Information Installing Exhaust Stacks With External Condensing Economizer Figure 2-5 OPTION 1: Recommended exhaust stack installation for steam generator/fluid heaters with Clayton condensing economizer. Sect02_Genrl-xx4_s.fm Steam Generator & Fluid Heater Installation Manual NOTE 1: Barometric dampers are recommended on all installations with stack heights over 20 feet (6 meters) and on low NOx units. NOTE 2: A removable, 4 feet (1.2 meters) minimum, stack section is recommended to facilitate steam generator/fluid heater maintenance and repair. NOTE 3: An air-tight backdraft (shut off) damper must be installed in the exhaust stack for installations in cold weather climates. NOTE 4: It is recommended that all stack sections be manufactured from 316L stainless steel Figure 2-6 OPTION 2: Recommended exhaust stack installation for steam generator/fluid heaters with Clayton condensing economizer. Sect02_Genrl-xx4_s.fm 2-12 04/21/2015 Section II - General Information 2.6 Piping 2.6.1 General Make sure no excessive strain or load is placed on any Clayton piping or their connections. Construct secure anchoring and support systems for all piping connected to the steam generator unit and associated water treatment package(s). Make sure anchoring and support systems keep motion and vibration to an absolute minimum. Ensure no extraneous vibrations are transferred to or from Clayton equipment. DO NOT use Clayton connections as anchor points. Spring-loaded pipe hangers are not recommended. All customer connections are limited to +200 pounds (+90 kg) of load and +150 foot-pounds (+200 N•m) of torque in all directions (X, Y, and Z). Properly designed flex lines and anchoring may be used to meet loading requirements. Fuel, combustion exhaust ducts, and fresh air supply connections are not designed for loads. Pipe routes must not be obstructive or create any potential safety hazards, such as a tripping hazard. Pipe trenches should be considered for minimizing pipe obstructions. Piping used to transfer a hot fluid medium must be adequately insulated. Pipe unions or flanges should be used at connection points where it is necessary to provide sufficient and convenient disconnection of piping and equipment. Steam, gas, and air connections should enter or leave a header from the top. Fluids, such as oil and water, should enter or leave a header from the bottom. A gas supply connection must have a 12–18 inch (30– 45 cm) drip leg immediately before Clayton’s fuel connection. Prevent dissimilar metals from making contact with one another. Dissimilar metal contact may promote galvanic corrosion. Globe valves are recommended at all discharge connections from Clayton equipment that may require periodic throttling, otherwise full port gate or ball valves should be used to minimize pressure drops. 2.6.2 Systems Table 2-2 below is for steam generators rated below 250 psig (17.2 bar). It indicates the recommended material to be used for the various piping systems associated with the installation. Table 2-2: Piping Recommendations SYSTEM RECOMMENDED MATERIAL/COMPONENTS Steam and Condensate System Steam and condensate system piping should be a minimum Schedule 40 black steel (seamless Grade B preferred). Refer to ASME guidelines for proper pipe schedules. Steam headers should contain a sufficient number of traps to remove condensed steam, and help prevent “water hammer.” The separator discharge requires one positive shut off globe valve at the separator discharge flange. Blowoff/Drain ASME codes require that all blowoff piping be steel with a minimum Schedule 80 thickness and all fittings be steel and rated at 300 psi. Boiler blow off piping should not be elevated. 04/21/2015 2-13 Sect02_Genrl-xx4_s.fm Steam Generator & Fluid Heater Installation Manual Table 2-2: Piping Recommendations SYSTEM RECOMMENDED MATERIAL/COMPONENTS Steam Trap(s) Discharge Steam trap(s) discharge piping should be Schedule 40 black steel. Pipe size should be the same as that of the separator trap(s) connection up to the first elbow. The pipe size must be increased one pipe size after the first elbow, and again after manifolding with additional units. It is preferable to have the trap return line installed so its entire run is kept below the feedwater receiver connection (to assist in wet layup). If this is not possible, then the line must be sloped downward toward the receiver at a rate of 1/8 inch per foot. Fuel (gas or oil) Schedule 40 black iron (See Section IV), local agencies/codes may require heavier pipe. Atomizing Air (oil only) Schedule 40 black iron (See Section IV) Safety Relief Valve Discharge Safety relief valves must discharge to atmosphere in a direction that will not cause harm to personnel or equipment. The discharge piping must not contain any valves or other obstruction that could in any way hinder the release of steam. A drip pan elbow with appropriate drains should be installed as shown in Figure 2-7. Back Pressure Regulator Installing a Back Pressure Regulator (BPR) on all installations is highly recommended by Clayton Industries. A BPR is required for all units sold with Auxiliary Pressure Control (APC), Master Lead-Lag, and automated startup controls. The BPR protects against drying-out and localized overheating of the heating coil during large steam pressure changes. Figure 2-7 Safety Relief Valve Discharge Sect02_Genrl-xx4_s.fm 2-14 04/21/2015 Section II - General Information NOTE It is the responsibility of the installer to ensure that all piping and fittings are properly rated (material type, thickness, pressure, temperature) for the intended system application. It is also the responsibility of the installing party to design all piping systems so as to ensure that Clayton specified flow and pressure requirements (See Section VI, Table 1) are satisfied. 2.6.3 Atmospheric Test Valve An important, yet often overlooked, function of a properly installed steam piping system is the ability to perform full load testing of the steam generator(s) when the main steam header is restricted from accepting steam. This is most commonly encountered during the initial start-up when commissioning a steam generator. This condition will also occur when it is necessary to test or tune a steam generator during periods of steam header or end-user equipment repairs, when header pressure must be maintained to prevent cycling the generator off, or when an overpressure condition exists while in manual operation. To facilitate full load testing of a steam generator, an easily accessible or chain operated, globe-type, atmospheric test valve must be installed in the steam header (downstream of a back pressure regulator, if so equipped, and upstream of at least one steam header isolation valve). The atmospheric test valve must be capable of passing 100 percent of the generator’s capacity. WARNING A discharging atmospheric test valve produces extremely high noise levels. Extended exposure to a discharging atmospheric test valve can lead to hearing loss. Installing a silencer is strongly recommended. 2.6.4 Steam Header and Steam Sample Points Clayton requires appropriately constructed steam header connections, and at least one steam sample point per generator. All steam header connections from and to Clayton’s equipment must originate from the steam header vertically upward prior to changing direction toward Clayton’s equipment. Clayton requires all steam sample connections used to measure steam quality, or efficiency, originate from the steam header vertically upward prior to heading to any sample cooler, water quality, or efficiency testing/measuring equipment. Clayton requires the equivalent of three (3) pipe diameters of uninterrupted straight lengths of steam header prior to and after the sample point. 2.7 Feedwater Treatment The importance of proper feedwater treatment cannot be over-emphasized. The Clayton steam generator is a forced-circulation, monotube, single pass, watertube-type packaged boiler requiring continuous feedwater treatment and monitoring. The water in the feedwater receiver is actually boiler feedwater. 04/21/2015 2-15 Sect02_Genrl-xx4_s.fm Steam Generator & Fluid Heater Installation Manual NOTE It is imperative that proper feedwater treatment chemicals and equipment are in place and operational prior to filling the heating coil. The Clayton Feedwater Treatment Manual, furnished with each new unit, provides detailed information regarding Clayton feedwater treatment requirements, products, and equipment. In general, the feedwater supplied to your Clayton steam generator must: • Hardness: 0 ppm (4 ppm maximum) • pH 10.5–11.5 (normal range), maximum of 12.5 • Oxygen free with an excess sulfite residual of 50–100 ppm during operation (>100 ppm during wet lay-up) • Maximum TDS of 8,550 ppm (normal range 3,000–6,000 ppm) • Maximum dissolved iron of 5 ppm • Free of suspended solids • Maximum silica of 120 ppm with the proper OH alkalinity NOTE Review the Clayton Industries Feedwater Treatment Reference Manual (P/N: R15216) for additional feedwater quality requirements, or contact your local Clayton Chemical Sales Representative. 2.7.1 Water Softeners Refer to the Clayton Water Softener Instruction Manual for detailed information regarding the installation, dimensions, and operation of Clayton water softening equipment. Some general guidelines are provided below. Cold water piping to the water softener(s), and from the water softeners to the makeup water control valve should be Schedule 40 galvanized steel or Schedule 80 PVC. Install anti-siphon device (if required by local health regulations) in the raw water supply line. 2.7.2 Make-up Water Line Sizing Table 2-3 shows the pipe sizes required from the water softener to hot-well. The supply pressure must be at least 65 psi (450 kPa). Sect02_Genrl-xx4_s.fm 2-16 04/21/2015 Section II - General Information Table 2-3: Makeup water valve and pipe sizes BHP 25 35 50 75 100 125 Make-up Valve (in.) 3/4 3/4 3/4 3/4 3/4 3/4 Minimum Line Size (in.) 3/4 3/4 3/4 3/4 1 1 BHP 150 200 250 300 350 400 Make-up Valve (in.) 3/4 3/4 1 1 1 1 Minimum Line Size (in.) 1 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 BHP 500 600 700 1000 1500 2000 Make-up Valve (in.) 1 1 2 2 2 1/2 3 Minimum Line Size (in.) 1 1/2 1 1/2 2 2 1/2 3 4 Note 1: All models use a makeup water solenoid valve. Note 2: Water flow is based on 44 lb. per hour per bhp (boiler horsepower). 2.8 Feedwater Supply Requirements The feedwater supply line sizing will be a minimum of one line size larger than the inlet connection size of the Clayton reciprocating, positive displacement (PD), feedwater pump. Fractional dimensions will be rounded up to the larger whole-sized dimension. NOTE Clayton, like all OEMs, takes advantage of the limited length and lower losses to minimize its internal line sizes. Like most manufacturers, this works well on Clayton’s internal piping and pump head designs because of the very short equivalent pipe lengths and quickly dividing flows (lower velocities) within our pump designs, which yield lower velocities and acceleration head. Unfortunately, the customer and installing contractor experience the reverse when designing their feedwater piping system as they are usually faced with much longer equivalent length pipe runs and/or have to deal with a pipe required to carry more than one generator’s flow. Therefore, it is critical for the installation designer to increase supply line sizes to meet Clayton’s requirements for velocity and acceleration head. See paragraph 2.8.2 and 2.8.3. 2.8.1 Multi-unit Systems A common design mistake is the installing of a single feedwater supply line to a common suction header for multiple reciprocating PD pumps. The preferred feedwater line design is providing each reciprocating PD pump with its own supply line and suction header. 04/21/2015 2-17 Sect02_Genrl-xx4_s.fm Steam Generator & Fluid Heater Installation Manual Connecting two or more reciprocating PD pumps to a common suction header IS NOT recommended. Designing such a pump system can frequently cause severe pump pounding, vibration, and premature check-valve, diaphragm, and electrical component failure. In addition, attempting to analyze the operation of multiple pumps connected to a common suction header through mathematical calculations is very difficult. 2.8.2 Velocity Requirements and Calculation Clayton requires the feedwater supply line maintain all flow velocities under one feet per second (1 ft/s). Customers must ensure their line sizing calculations clearly show that supply pipe sizes are sufficiently large to maintain the less than 1 ft/s under all operational conditions. Refer to the charts in Figure 2-8 and 2-9 for velocity requirements. Velocity of a fluid is the amount of fluid Flow passing through an Area, and the formula is V=F/A. Velocity is required in ft/sec for our use, so we must express our generators water flow in cubic feet and divide that by an area expressed in square feet. Clayton’s generator water flows are all based on 44 lbs per boiler horsepower per hour; therefore, we must convert the pounds of water to cubic feet of water, and then convert the hour to seconds. Let us find the velocity of 3 x 150 bhp generators running at 100% in a common manifold. This can be done by first calculating the total flow of water at the maximum firing rate. Since Clayton wants a minimum of 44 lbs/bhp-hr, the total flow required is: F = (3 × 150 bhp × 44 lbs/bhp-hr) = 19,800 lbs/hr Next, we need to convert the flow from lbs/hr to ft3/hr by multiplying the flow by the conversion factor of 0.01602 ft3/lb of water. The converted flow is: F = 19,800 lbs/hr × 0.01602 ft3/lb = 317.2 ft3/hr Then, we need to convert hours to seconds. Since one hour has 3600 seconds, we simply divide the 317.2 ft3/hr by 3600. The converted flow is: F = (317.2 ft3/hr) ÷ (3600 sec/hr) = 0.0881 ft3/sec Now that we have the flow (F), we need to know the area through which it will flow. Area is calculated by the formula A = r2 were is a constant equal to 3.14159, and r is the radius of the pipe ID being used. For this example, we will use 3-inch pipe. We will discount the differences between the ID of varying pipe schedules, water temperature, etc., to make this simple for the field. These are not meaningful for a quick check of the installation. To successfully complete the velocity calculation, we need to work with feet, so a conversion from inches to feet is required. A 3 inch ID pipe has a radius of 1.5 inch. To convert inches to feet, divide the inches by 12 in./ft; therefore, in our example the radius is 1.5 in. ÷ 12 in./ft = 0.125 ft A = r2 = 3.14159 × (0.125 ft) 2 = 0.049 ft2 Now that we have both the desired flow (0.088 ft3/sec) and the available area (0.049 ft2) of the 3-inch pipe it must pass through, we can calculate the velocity. V = F÷A = (0.0881 ft3/sec) ÷ (0.049 ft2) = 1.8 ft/sec NOTE: Unfortunately, the velocity (V) in our example exceeds Clayton’s maximum ft/sec. Sect02_Genrl-xx4_s.fm 2-18 04/21/2015 Section II - General Information Figure 2-8 Velocity requirements for 25–1,000 bhp 04/21/2015 2-19 Sect02_Genrl-xx4_s.fm Steam Generator & Fluid Heater Installation Manual Figure 2-9 Velocity requirements for 1,200–4,000 bhp Sect02_Genrl-xx4_s.fm 2-20 04/21/2015 Section II - General Information The more relevant issue for this example is what size pipe manifold, as a minimum, do the 3 x 150 bhp generators need to meet Clayton’s 1 ft/sec maximum flow velocity. This can be calculated using the same velocity equation V = F ÷ A. To find and area, we solve the equation for A (area), which is done by multiplying both sides of the equation by A, and dividing both sides of the equation by V; therefore, the area is equal to the flow divided by the velocity, or A = F ÷ V. From our example above, we know that the flow is 0.0881 ft3/sec, and the maximum velocity Clayton requires is 1 ft/sec; therefore, we simply divide them get the area. A = F ÷ V= 0.0881 ft3/sec ÷ 1 ft/sec = 0.0881 ft2 But we want a pipe size so we must convert an area in ft2 backwards to a diameter in inches. To accomplish this we simply work the area of a circle backwards. From above we learned that the area of a pipe ID is A = r2 so to find the r (radius) we simply divide both side by , and then take the square root of the result, r = (A ÷ ). R = (A ÷ ) = (.0881 ft2 ÷ 3.14159) = 0.028 = 0.1675 ft Remember this is a radius in feet, so we need to convert it to a diameter by multiplying by 2 and converting feet to inches for pipe sizes. Pipe diameter size in feet = 0.1675 ft × 2 = 0.3349 ft Now feet to inches: 0.3349 ft × 12 in./ft = 4.02 inch pipe This shows that the 3 x 150 bhp generators require at least a 4-inch pipe size to manifold all 3 x 150s and meet Clayton’s maximum flow velocity of 1 ft/sec. Remember that this must be done for each leg of the entire supply piping system using the specific flows in each leg. 2.8.3 Acceleration Head (Ha) Requirements On feedwater supply runs longer than 15 feet, or with multiple pump sets, customers must complete acceleration head loss calculations to show acceleration head losses are less than 0.75 foot/foot of equivalent pipe run for open hot-well systems (water temperatures less than 210° F {99° C}), and less than 0.5 foot/foot of equivalent pipe run for deaerator or semi-closed systems (water temperatures over 212° F {100° C}). UNDER NO CIRCUMSTANCES SHOULD THE IMPACT FROM Ha TO NPSHA BE IGNORED (See paragraph 2.11.1.). NOTE All water flow calculations must be based on 44 lb. per hour per boiler horsepower adjusted for hot-well tank temperature. 2.9 Flexible Feedwater Hose Connection And Connection Sizing A two-foot flexible hose is required for connecting directly to the inlet of a Clayton reciprocating PD pump from the feedwater supply line. In some cases, a two-foot flexible hose may also be required at the reciprocating PD pump discharge outlet. The flexible section must be appropriately rated to satisfy pressure and temperature requirements. 04/21/2015 2-21 Sect02_Genrl-xx4_s.fm Steam Generator & Fluid Heater Installation Manual 2.9.1 Supply Side Connections Clayton’s reciprocating PD pumps require that the connection made directly to the pump’s inlet be a flexible hose section. This hose section should be a bellows-type hose protected by a stainless steel wire mesh sleeve. It must have at least a 24 inch (61 cm) length with a minimum 18 inch (45.5 cm) long-live length. This flexible hose section must be appropriately rated to meet the pressure and temperature requirements of the feedwater supply system. The supply-side piping system must include a pipe anchor directly at the inlet (hot-well/DA) side of the flexible connector. 2.9.2 Discharge Side Connections A flexible hose section is required at the reciprocating PD pump discharge outlet whenever it is relocated from its original, factory-designed, installation location. This hose section should be a bellows-type hose protected by a stainless steel wire mesh sleeve. It must have at least a 24 inch (61 cm) length with a minimum 18 inch (45.5 cm) long-live length. Because Clayton’s mono-flow heating coil design usually increases feedwater discharge pressures from Clayton’s reciprocating PD pump, this flexible hose section must be appropriately rated to meet the pressure and temperature requirements of the reciprocating PD pump output. The flexible hose rating requirements for the discharge will differ from the rating requirements for the inlet flexible hose section. Contact Clayton Engineering for the feedwater pressure of the specific generator model. 2.10 Pump Suction and Discharge Piping System Design The suction piping system is a vital area of the piping supply system. Therefore, its design requirements deserves more careful planning. 2.10.1 General Layout Guidelines • Lay out piping so no high points occur where vapor pockets may form. Vapor pockets reduce the effective flow area of the pipe and consequently make pump priming and operation difficult. Vent any unavoidable high points and provide gauge and drain connections adjacent pump. • Install eccentric-type pipe reducers when required. Make sure these reducers are installed with the flat side up. • Keep piping short and direct. • Keep the number of turns to a minimum. • Keep friction losses to a minimum by incorporating smooth fluid flow transitions in the piping layout. This can be accomplished with long radius elbows, two 45° elbows, or 45° branch laterals instead of tees. • DO NOT use Clayton equipment for pipe support or pipe anchoring. It is the responsibility of the installation contractor and the customer to provide adequate and proper pipe supports and anchors. Clayton recommends all steam/fluid heaters, PD feedwater pumps, and water treatment skid pipe supports and anchors use floor-mounted structural steel. Sect02_Genrl-xx4_s.fm 2-22 04/21/2015 Section II - General Information 2.10.2 Pipe Sizing Guidelines 2.10.2.1 Suction Piping Clayton tends to follow the guidelines set forth by the Hydraulic Institute (HI) for positive displacement piston pumps. Equivalent pipe lengths for pipe fittings (elbows, tees, etc.) can be found in the HI reference charts. NOTE While Clayton cannot assume responsibility for the piping system into which our pump is installed, we can provide valuable guidelines for designing a piping system properly. Suction line sizing is a major factor in the successful operation of any pump. Many pump problems result from a suction line that is too small in diameter, or too long. A properly designed piping system can prevent problems, such as: • Fluid flashing—Entrained fluid gases effuse when pressure in piping or pump falls below fluid vapor pressure. • Cavitation—Free gases in a fluid being forced back into the fluid. These implosions cause severe pressure spikes that pit and damage pump internal parts. • Piping vibration—This can result from improper piping support, cavitation, or normal reciprocating pump hydraulic pulses. • Noisy operation—Most present when pump is cavitating. • Reduced capacity—Can result from fluid flashing. If it is, this is an indication that the pumping chambers are filling up with gases or vapors. These problems can reduce a pump’s life and are a potential hazard to associated equipment and personnel. It is possible to fracture piping and damage the pump components with high pressure surges occurring when fluid is flashing or cavitating. Suction piping must be a minimum of one size larger than the pump suction connection. The actual line sizes will depend on meeting flow velocity maximums (see Figure 2-8 and 2-9 on pages 2-19 and 2-20, respectively), acceleration head calculations (see paragraph 2.11.3), and NPSH requirements (see Table 2-4 on page 2-25). 2.10.2.2 Discharge Piping Normally, discharge pipe sizing is not an issue for a standard Clayton generator installation. But, when floor space is limited at the installation site, Clayton’s close-coupled reciprocating PD pump will require relocating from its originally-designed location. In these cases, certain precautionary changes must be made to the pipe runs between the reciprocating PD pump and the heating coil inlet. Clayton recommends contacting a factory engineer to discuss any piping changes and obtain the generator’s necessary feedwater pressure requirement. 04/21/2015 2-23 Sect02_Genrl-xx4_s.fm Steam Generator & Fluid Heater Installation Manual The required piping changes are as follows: • Connect a flexible hose section directly to the reciprocating PD pump’s discharge outlet. (See paragraph 2.9.2 for flexible hose section requirements.) • Keep discharge lines as short and direct as possible, well supported, and firmly anchored. This will ensure minimal pipe vibration, whether hydraulic or mechanical, that can be detrimental to the pump and generator. Avoid “dead ends” and abrupt direction changes as much as possible. • Always incorporate 45° angles in the discharge pipe runs by using lateral tees and 45° elbows. DO NOT connect the pump’s discharge piping directly to a 90° tee/elbow pipe, or other acute-angled piping. These types of connections will create “standing wave” or “bounce-back,” either audible or sub-audible, that causes excessive vibration and noise. • Use laterals in place of tees with the bottom of the Y facing the direction of pumped water flow. Use long radius elbows, or two 45° elbows, throughout the discharge piping system from the flexible hose discharge connection to the heating coil inlet connection. • Increase the pipe sizes by at least one full size over the reciprocating PD feedwater pump’s discharge connection (i.e.: a 1 1/2 or 2 inch discharge requires an increase to 3 inches minimum). • Use of butt-weld pipe with weld-neck flange construction throughout the discharge pipe run is recommended. • Discharge flow velocities must be maintained below 5 ft/sec. maximum. • DO NOT install angle valves, globe valves, reduced port regular opening valves, restricting plug valves, flow restriction orifices, or small ventures in the discharge pipe run. • DO NOT install any quick-closing valves, which can cause hydraulic shock (water hammering) in the discharge piping run. • Connect the pressure relief valve and pressure gauge with snubber ahead of any block valve so that the pump discharge pressure is always reflected at the relief valve. The relieving capacity of the valve must exceed the full capacity of the pump to avoid excessive pressure while relieving flow. Use only full-sized relief line design with no restrictions. • Should the Clayton reciprocating PD pump’s pressure relief valve be removed, it must be replaced with a properly sized and correctly set pressure relief valve. Relief valve discharge must not be piped to reciprocating PD pump’s suction line. • Install a 2-inch NPTF weld couplet vertically upward, as close as possible, to the reciprocating PD pump’s discharge connector to allow the addition of nitrogen-filled pulsation dampeners. • All discharge pipe and pipe fittings must be at minimum Schedule 80. 2.11 Net Positive Suction Head (NPSH) NPSH relates to the fluid pressure (generally in terms of “head” of water, or psi) that a pump needs to prevent flashing or cavitation within the pump, primarily in the suction check-valve area. Flashing and cavitation will reduce necessary flow rates and cause damage to the internal pump components and coil. NPSH is divided into two important aspects, (A) what is available (NPSHA) from the suction vessel, booster pump(s), and piping, and (B) what is required by the pump (NPSHR). Sect02_Genrl-xx4_s.fm 2-24 04/21/2015 Section II - General Information 2.11.1 NPSHA Pump NPSHA is the usable pressure (usually expressed in feet of water column or psi) available at the inlet of the pump. For Clayton systems that typically operate with near-boiling water, NPSHA is determined by the elevation difference between the operating hot-well tank water level and the inlet to the pump, minus frictional losses and minus acceleration head losses. NOTE If a hot-well tank cannot be sufficiently elevated to supply the required NPSHA, a booster pump is required. To convert booster pump pressure (psi) to foot of head, use the following formula: psi (2.3067) = ft of water. Booster pumps should be placed adjacent to the feedwater supply (suction) vessel. The total suction system’s NPSHA must be greater than the booster pump’s NPSHR. The discharge head of the booster pump must be sufficient to provide a pressure of at least 25% greater than Clayton’s reciprocating PD pump’s NPSHR, plus pipe friction losses, plus acceleration head losses, and plus 2.5 ft. Velocity and acceleration head design requirements are specified in paragraphs 2.8.2, page 2-18, and 2.8.3, page 2-21, and velocity charts in Figures 2-8 and 2-9, pages 2-19 and 2-20, respectively. 1) Suction System: NPSHA = Receiver Elevation Head or Booster Pump Head – Friction Loss – Acceleration Head Loss – Pump Head Elevation (Typically 2.5 ft. [0.76 m] above ground.) 2) NPSHR = Clayton Feedwater Pump Net Positive Suction Head Required (See Table 2-4.). 3) NPSHA must be at least 25% greater than NPSHR. (NPSHA > 1.25 NPSHR) NOTE: NPSHA is increased by increasing receiver head, booster pump head, or line size. A suction pulsation dampener or stabilizer directly adjacent to the Clayton feedwater pump connection is required. 2.11.2 NPSHR Pump NPSHR is the pressure (usually expressed in feet of water column or psi) required at the inlet of the pump that will enable the pump to operate at rated capacity without loss of flow due to flashing or cavitation in the pump. The NPSHR is relative to the pump inlet (suction) connection. The NPSHR number for a Clayton pump was determined experimentally by Clayton (see Table 2-4). 04/21/2015 2-25 Sect02_Genrl-xx4_s.fm Steam Generator & Fluid Heater Installation Manual Table 2-4: Clayton’s NPSH height requirements a Model Feet Meters Model Feet Meters E-154 E-204 E-254 E-304 E-354 E-404 18 13 13 18 30 15 5.5 4.0 4.0 5.5 9.2 4.6 E-504 E-604 E-654 E-704 E-804 E-1004 15 18 18 30 10 10 4.6 5.5 5.5 9.2 3.0 3.0 a Requirements shown are based on Clayton’s standard reciprocating PD pump usage. Alternate pumps that require higher NPSHR are used on some generators. Check Clayton’s P & I D drawing for specific requirements. NOTE Water flow is based on 44 lb. per hour per bhp. NPSHRs shown are for 150 psi design steam pressure. Higher steam pressures could change these numbers. 2.11.3 Acceleration Head (Ha) Unlike centrifugal pumps that provide a smooth continuous flow, positive displacement pumps (typically used by Clayton) cause an accelerating and decelerating fluid flow as a result of the reciprocating motion and suction valves opening and closing. This accelerated and decelerated pulsation phenomenon is also manifested throughout the suction pipe. The energy required to keep the suction pipe fluid from falling below vapor pressure is called acceleration head. For installations with long piping sections, this becomes a significant loss to overcome and must be carefully considered. If sufficient energy is absent, then fluid flashing, cavitation, piping vibration, noisy operation, reduced capacity, and shortened pump life can occur. To calculate the Ha required to overcome the pulsation phenomenon, use the following empirical equation: Ha = LVNC gk where: Ha = Head in feet (meters) of liquid pumped to produce required acceleration L = Actual suction pipe length in feet (meters) V = Mean flow velocity in suction line in feet per second (m/s) (See Figure 2-8 and 2-9, page 2-19 and 2-20, respectively.) N = Pump speed in rpm (See Table 2-5, below.) C = Pump constant factor of ... 0.400 for simplex single acting 0.200 for duplex single acting (J2 pump) 0.066 for triplex single acting 0.082 for quadplex single acting (J4 pump) 0.041 for octoplex single acting (2xJ4 pump) Sect02_Genrl-xx4_s.fm 2-26 04/21/2015 Section II - General Information g = Acceleration of gravity = 32.2 ft/s2 (9.8 m/s2) k = Liquid factor of ... 1.5 for water 1.4 for deaerated water 1.3 for semi-closed receiver water Table 2-5: Clayton Pump Speeds Generator E154 E204 E254 E304 E354 E404 E504 E604 E654 E704 E804 E1004 Pump Speed (RPM) 432 288 360 432 510 288 372 450 512 552 n/a a n/a a a These calculations do not apply to the multistage centrifugal pumps used by E804 and E1004 generators. Since this equation is based on ideal conditions of a relatively short, non-elastic suction line, calculated values of Ha should be considered as approximations only. NOTE As pump speed (N) is increased, mean flow velocity (V) also increases. Therefore, acceleration head (Ha) varies as the square of pump speed. NOTE Acceleration head varies directly with actual suction pipe length (L). IMPORTANT ACCELERATION HEAD IS A SUCTION PIPING SYSTEM FACTOR THAT MUST BE ACCOUNTED FOR BY THE PIPING SYSTEM DESIGNER. MANUFACTURERS CANNOT ACCOUNT FOR THIS IN THEIR DESIGNS BECAUSE OF THE LARGE VARIETY OF APPLICATIONS AND PIPING SYSTEMS PUMPS ARE INSTALLED IN. NOTE If acceleration head is ignored or miscalculated, significant pump and piping system problems (suction and discharge) may result. Clayton recommends placing a suction pulsation dampener or stabilizer adjacent to the positive displacement reciprocating pump suction connection. This will help to protect the booster pump from the pulsating fluid mass inertia of the reciprocating PD pump and to reduce the effect of acceleration head. 04/21/2015 2-27 Sect02_Genrl-xx4_s.fm Steam Generator & Fluid Heater Installation Manual 2.12 General Installation Concerns 2.12.1 Charge Pumps Charge (booster) pumps should be sized to 150% of rated Clayton pump volume. Charge pumps must be centrifugal-type pumps—not positive displacement pumps. 2.12.2 Charge Pumps Are Not A Substitute Charge pumps are not a good substitute for short, direct, oversized, suction lines. They are also not a substitute for the computation of available NPSH, acceleration head (Ha), frictional head (HF), vapor pressure, and submergence effects being adequately considered. 2.12.3 Multiple Pump Hookup The preferred configuration for connecting two or more reciprocating pumps in a system is to provide each pump with their own piping system. This will ensure each pump is isolated from the effects of another pump’s cyclical demands. Connecting two or more reciprocating pumps to a common suction header IS NOT recommended. Designing such a pump system can frequently cause severe pump pounding, vibration, and premature checkvalve and diaphragm failure. In addition, attempting to analyze the operation of multiple pumps connected to a common suction header through mathematical calculations becomes impossible. 2.12.4 Pumphead Cooling Water System (Clayton Feedwater Pumps) Clayton feedwater pumps require pumphead cooling water in the following applications: • high coil feed pressures - for pump discharge pressures above 500 psi (34.5 bar), typically for E354s, E654s, and E704s • high pump speeds - for pump speeds greater than 450 rpm, typically for E354s, E654s, and E704s (see Table 2-5) • high-temperature supply water - supply water from a DA, SCR, or receiver with temperatures above 210° F (98° C) The cooling water temperature must be below 75° F (24° C). The supplied water pressure should be 35–65 psi (2.4–4.5 bar) with a flow rate of 1.5 gpm (5.7 lpm) minimum. 2.13 Electrical All customer-supplied electrical wiring must be properly sized for the voltage and amperage rating of the intended application. Full load amperage (FLA at 460V) requirements for each model are provided in Table 6-1 of Section VI. Use the appropriate multiplier, provided in the table below, to determine the full load amperage requirements for other voltages (FLA at 460V times the multiplier). VOLTAGE 208 230 380 575 Sect02_Genrl-xx4_s.fm MULTIPLIER 2.2 2.0 1.1 0.8 2-28 04/21/2015 Section II - General Information A fused disconnect switch (customer furnished) must be installed in accordance with NEC 430 and should be located within view of the steam generator. The switch should be easily accessible to operating personnel. Clayton provides a set of terminals in the steam generator electrical control cabinet for wiring an emergency stop device (customer furnished). NOTE Additional access holes are located in the bottom of the electrical control cabinet(s). DO NOT make any holes in the sides or top of the electrical cabinet(s). Clayton strongly recommends surge protection for all its equipment. Isolation transformers are recommended for areas subject to electrical variations due to weather, weak or varying plant power, or old systems. Isolation transformers are required on all electrical systems that are based on delta distribution systems. Clayton recommends electrical connections be made through a grounded wire system only. Clayton electronics cabinet devices are rated to function properly at typical boiler room temperatures not exceeding 120° F (49° C). For boiler room installations where temperatures are expected to rise above 120° F (49° C), installation of a Clayton electronics cabinet cooler is required. This cooler requires a supply of clean, dry compressed air at 40 scfm (1.13 m3/min.) at 100 psi (6.9 bar). 2.14 Electrical Grounding Clayton’s steam generator, fluid heater, and water skid installations must have an electrical grounding network with a resistance no higher than 2 Ohms to earth ground when measured at its control box(es). Clayton requires a separate, direct earth ground at each of its unit installations. Grounding wires must be routed directly with electrical power supply wiring and sized according to the connected amperage, but never less than 8 awg. A separate ground wire must be run to each steam generator/fluid heater frame and water skid frame. 04/21/2015 2-29 Sect02_Genrl-xx4_s.fm Steam Generator & Fluid Heater Installation Manual (This page intentionally left blank.) Sect02_Genrl-xx4_s.fm 2-30 04/21/2015 SECTION III - CLAYTON FEEDWATER PUMPS AND WATER SYSTEMS 3.1 GENERAL Clayton steam generator feedwater systems are designed with an open (hotwell), deaerator (D/A), or Semi-closed Receiver (SCR). The selection of the proper feedwater system is determined by the steam generator’s application, the installation environment, and other factors. Each system is discussed in detail in later paragraphs in this section. The feedwater system’s pipes, as well as the heating coil, are susceptible corrosion if proper feedwater treatment is neglected. Corrosion in the pipes are due to three fundamental factors—dissolved oxygen content, low pH, and temperature. Oxygen is required for most forms of corrosion. The dissolved oxygen content is a primary factor in determining the severity of the corrosion. Removing oxygen, and carbon dioxide, from the feedwater is essential for proper feedwater conditioning. Temperature and low pH affects the aggressiveness of the corrosion. Deaerators are designed to remove most of the corrosive gases from the feedwater. Deaeration can be defined as the mechanical removal of dissolved gases from a fluid. There are many types of deaerators; however, the ones most commonly used for deaerating boiler feedwater are the open (atmospheric), pressurized jet spray, and tray type. To effectively release dissolved gases from any liquid, the liquid must be kept at a high temperature. Deaerators are pressurized above atmospheric pressure (typically 3–15 psig) to maintain the feedwater at a higher boiling point. The increased pressure and temperature releases the dissolved gases from the feedwater and those gases are vented to atmosphere. There are four skid package options available depending on the feedwater system (all options are not available for all models - contact your Clayton Sales Representative). The systems, skid package options, and required customer connections are described below. 3.2 SKID PACKAGES A. Individual Components The steam generator unit and all water treatment components are furnished separately. Placement of each component and its assemblies and interconnections are determined by the installer. See Section 3.3 for customer connections. B. Feedwater Receiver Skid A separate skid consisting of the feedwater receiver, booster pump(s), and electrical control box mounted on a common frame is provided along with the steam generator. Interconnecting piping between the feedwater receiver and booster pump(s), if applicable, and feedwater receiver trim component mounting, are included. If applicable (>200 bhp), electrical connections between the water level control, makeup water valve, and skid electrical control box are also included. No other water treatment components or interconnections are provided on this skid. 04/22/2015 3-1 Sect03_FeedwtrSys_xx4_f.fm STEAM GENERATOR & FLUID HEATER INSTALLATION MANUAL C. Water Treatment Skid All water treatment components are mounted on a skid and provided along with the steam generator. Components include receiver, softeners, chemical pumps, blowdown tank, control box, and booster pumps if applicable. Skid piping and electrical interconnections between the skid components are included. NOTE All Clayton-supplied water skids must be fully grouted in place once leveling and anchoring are complete. D. Generator Skid The steam generator(s) and water treatment components as listed in “C” above, are all mounted on a single skid. Skid piping and electrical interconnections between components are included. NOTE On SCR system skids, the SCR is mounted and piped, but removed for shipment for reassembly by the installing contractor. NOTE Clayton reserves the right to ship loose any equipment that cannot be safely shipped or installed. Some skid components may require re-installation on site. NOTE All Clayton-supplied water skids must be fully grouted in place once leveling and anchoring are complete. E. Clayton Feedwater Pump Skids Clayton feedwater pumps are designed to fulfill the needed water volume and water pressure requirements of the heating unit. These pumps are mounted on a skid frame that includes all the equipment needed to operate the pump, such as motors and oil pumps. These feedwater pump skids are standard equipment for all steam generators and fluid heaters. Piping, piping assemblies, valves, and other plumbing components connecting the feedwater pump skid and the heating unit are supplied by Clayton. Water supply piping to the feedwater pump skid are the responsibility of the installer, with the exception of a generator skid. On generator skids, water supply piping to the feedwater pump skid are part of the generator skid package. For determining the proper water supply pipe sizing, see Section 2.12. F. Clayton-RotoJet Feedwater Pump Skids Because of the size requirements of this centrifugal-style feedwater pump, this feedwater pump skid must be installed independent of any water skid package that Clayton offers. For customer connection requirements, see Table 3-1. Sect03_FeedwtrSys_xx4_f.fm 3-2 04/22/2015 Section III Water supply piping to the feedwater pump skid are the responsibility of the installer. For determining the proper water supply pipe sizing, see Section 2.12. 3.3 CUSTOMER CONNECTIONS The required customer connections for the typical water system components and feedwater pump supply included with open and deaerator feedwater receiver systems are identified in Tables 3-1 and 3-2 below. The type and size of each is provided on supplemental drawings and instructional literature. Table 3-1: Hotwell (Open) and Deaerator Systems Customer Connection Feedwater a Outlet X X X Skid Type None Condensate Skid Water Skid Generator Skid a Feedwater Vent X X X X Drain X X Overflow X X Overflow/ Condensate Traps Drain Returns Returns X X X X X X X X X ClaytonRotoJet Feedwater Feedwater Steam Chemical Makeup Pump Pump Heating Injection Water Supply Supply X X X X X X X X X X X X X X X X X X outlet connections apply only on Condensate and Water Skids without Booster Pumps. Table 3-2: Hotwell (Open) and Deaerator Systems D/A ONLY Customer Connections Skid Type None Condensate Skid Water Skid Generator Skid 3.4 Booster Pump(s) Inlet X Outlet Recirc X X X Water Softener(s) Inlet X X X X Outlet Drain X X X X X X Blowdown Tank Inlet X X Outlet X X X X Vent X X X X Cooling Safety Water Valve Inlet Out X X X X X X BPR Outlet X X X X PRV Inlet X X X X OPEN SYSTEM (Refer to P&ID Drawings R-16099 and R-16100.) An Open System is one in which the makeup water, condensate returns (system and separator trap returns), chemical treatment, and heating steam are blended in an atmospheric Feedwater Receiver Tank, (vented to atmosphere - under no pressure). Open Feedwater Receiver Systems are sized to provide the necessary volume of feedwater and sufficient retention time for the chem- 04/22/2015 3-3 Sect03_FeedwtrSys_xx4_f.fm STEAM GENERATOR & FLUID HEATER INSTALLATION MANUAL ical treatment to react. Condensate, separator trap returns and feedwater treatment chemicals are injected at the opposite end of the tank as the feedwater outlet connection. This helps to avoid potential feedwater delivery problems to the Booster or Feedwater Pump(s), and to provide sufficient reaction time for the chemical treatment. If not skid mounted, the Feedwater Receiver should be installed horizontally, as shown in Drawing R-16099. If the Feedwater Receiver cannot be elevated to provide the required NPSH, Booster Pumps must be used. The Feedwater Receiver can be insulated to maximize heat retention. Installation guidelines for the Feedwater Receiver are provided below. Descriptions for the other water treatment and accessory components, shown in R-16099, are provided in Section VII (Optional Equipment) and/or in the Clayton Feedwater Treatment Manual. NOTE All piping to and from the feedwater receiver must remain the same or larger size as the tank connection and not reduced. See Table 3-3 below for connection requirements. Table 3-3: Feedwater Receiver Connections Feedwater Outlet Gravity Fill Vent Chemical Injection Overflow This is the supply connection for properly-treated feedwater to the booster pump(s) or feedwater pump(s). Depending on the tank size, this connection may be either on the bottom or on the side of the tank. A valve and strainer (0.125 mesh) must be installed in the feedwater supply piping at the inlet to each pump (shipped loose if Clayton furnished - except on Skids). Feedwater line must be constructed to provide the required NPSH, velocity under 1 ft/s, and acceleration head losses less than those shown in Section 2.11 to the feedwater pump inlet. Restrictions in this line will cause water delivery problems that may result in pump cavitation and water shortage problems in the heating coil. Install a pipe tee in the feedwater outlet line just below the feedwater outlet connection. On an elevated receiver system, this pipe tee provides a connection for the gravity fill plumbing coming from the heating coil. Vent piping must be installed so as not create back pressure on the hotwell. The vent pipe should be as short as possible, contain no valves or restrictions, and run straight up and out. Ninety degree elbows are to be avoided. A 45o offset should be provided at the end of the vent line to prevent system contamination during severe weather conditions and/or during shutdown periods. One common feedwater chemical injection connection is provided into which all feedwater treatment chemicals are introduced. A check-valve must be installed in the discharge line of each chemical pumping system. No valves are to be installed in the overflow piping. Overflow piping must be plumbed to the blowdown tank discharge piping at a point prior to the temperature valve sensor. The overflow line must be full size, not reduced. Clayton recommends installing a “Ptrap” on all overflow lines. Sect03_FeedwtrSys_xx4_f.fm 3-4 04/22/2015 Section III Table 3-3: Feedwater Receiver Connections Drain A valve must be provided in the drain line. As indicated above, the drain line can be tied into the overflow line as long as the line size downstream of the merge remains at least the size of the overflow connection on the tank. NOTE The Feedwater Receiver drain and overflow lines (run independently or tied together) may contain up to 212o F (100o C) water and must be routed to the Blowdown Tank discharge piping at a point prior to the temperature valve sensor. The condensate return connection is the point where all system condensate returns, Condensate Returns, separator trap discharge, and heating steam are introduced. The Hotwell may use one or Temperature two condensate return connections, depending on the tank size and return volume. This Control injection point is located below the water line and connected to a sparger tube(s). Introducing the steam and hot condensate below the water line in conjunction with & using the sparger tube reduces the velocity and turbulence created at the injection point, while minimizing flash steam losses and noise. On tanks containing two condensate Sparger return connections one is used for system condensate returns, the other is used for the Tube(s) separator trap discharge and heating steam. In all cases, a check-valve must be installed in the separator trap discharge, condensate return, and steam supply lines, to prevent back-feeding. The check-valve must be located as close to the feedwater tank as possible. When installing a Sparger Tube(s) it must be installed so that the holes are in a horizontal position. This is confirmed on Clayton manufactured Hotwells (up to 200 BHP) by visual verification that the “X” stamping on the external section is in the “12 o’clock” position. Refer to Drawing R-16099 for the proper temperature control valve configuration. NOTE Clayton feedwater receivers are sized for proper flow and chemical mixture. If a customer’s condensate system creates large surges in returns at start up or while in operation, it may cause the feedwater receiver to overflow. Proper evaluation of the condensate return system and final feedwater receiver sizing is the customer’s responsibility. 3.5 DEAERATOR (D/A) (Refer to P&ID Drawing R-16595.) Effective control of the pressure in the deaerator is essential to proper performance and operation of the Clayton steam generator system. Most deaerators have high and low pressure condensate return inlet connections. The high temperature condensate should be introduced into the D/A through a sparger tube. Condensate returns affect the pressure and water temperature in the D/A. Introducing condensate return increases the pressure in the D/A and, conversely, reducing the amount of condensate return decreases the pressure in the D/A. When the quantity of condensate return is insufficient to maintain the desired water level in the D/A, relatively cool makeup water is admitted. This results in a pressure drop (sometimes sudden) in the D/A. This distorts the saturation pressure-temperature relationship causing the high temperature water in the 04/22/2015 3-5 Sect03_FeedwtrSys_xx4_f.fm STEAM GENERATOR & FLUID HEATER INSTALLATION MANUAL D/A to flash, releasing steam. Some amount of the water in the supply line to the feedwater pump also flashes. This condition may result in cavitation of the feedwater pump, impeding feedwater delivery to, and resulting in an overheat condition of the heating coil. On the other hand, if the water in the D/A is overheated due to an excessive amount of condensate return, some of this heat is vented off as steam to prevent over-pressurizing the D/A. Pressure regulating valves, PRV/BPR, are used to maintain a stable pressure in the D/A. A Pressure Regulating Valve (PRV) is used to inject steam into the D/A when a pressure drop is sensed. The PRV for this service is typically pilot operated. The downstream sensing line should be connected to the deaerator head rather than the PRV downstream pipe line. This will prevent any control variations due to the pressure loss in the line. A Back Pressure Regulator (BPR) is used to vent steam during periods of overpressure. When large amounts of hot condensate are returned, an amount of steam will be released momentarily—this is normal. Clayton uses a separator with dual steam traps on deaerator applications to minimize this condition. With intermittent conditions of condensate returns at different temperatures and cold makeup, it may not be possible to absorb all the heat from the hot condensate. Deaerator pressure fluctuations should be controlled to within 2-3 psig. The deaerator should be installed horizontally. The higher the D/A can be elevated above the booster pump(s) the less sensitive the feedwater delivery system will be to pressure variations. Other factors, such as friction loss in the feedwater supply line and the Net Positive Suction Head (NPSH) characteristics of the booster pump(s), should be considered when planning the deaerator installation. Clayton requires booster pumps for most D/A installations. The D/A can be insulated to maximize heat retention. Descriptions for the water treatment and accessory components, as shown in drawing R-16595 are provided in Section VII (Optional Equipment) and/or in the Clayton Feedwater Treatment Manual. NOTE All piping to and from the deaerator must remain the same size or larger than the tank connection. Always check feedwaer pump pipe size requirements and follow the larger pipe size. See Table 3-4 below. Table 3-4: Deaerator Connections Feedwater Outlet This connection is used to deliver properly treated feedwater to the booster pump(s) it is typically on the bottom of the tank. A valve and strainer must be provided in the feedwater supply piping at the inlet to each pump. The feedwater line must be constructed so as to provide the required NPSH to the feedwater pump inlet. Restrictions in this line will cause water delivery problems that may result in pump cavitation and water shortage problems in the heating coil. Do not insulate this line. Cooling in the pump suction line is beneficial during periods of fluctuating pressure in the deaerator. See Section 2.9. Sect03_FeedwtrSys_xx4_f.fm 3-6 04/22/2015 Section III Table 3-4: Deaerator Connections Gravity Fill Vent Chemical Injection Overflow Trap Drain A pipe tee should be installed in the feedwater outlet line just below the feedwater outlet connection. On an elevated D/A System, this pipe tee provides a connection for the gravity fill plumbing. On a receiver system which uses Booster Pumps, install a pipe plug in the gravity fill tee connection. The deaerator must vent the liberated gases to be effective. Some steam is always vented with these gases. One common feedwater chemical injection connection is provided into which all feedwater treatment chemicals are introduced. A check valve must be installed in the discharge line of each chemical pumping system. No valves are to be installed in the Overflow Trap piping. The Overflow Trap piping must be plumbed to the blowdown tank discharge piping at a point prior to the temperature valve sensor. A drain valve must be provided in the drain line. As indicated above, the drain line can be tied into the overflow line as long as the line size downstream of the merge remains at least the size of the overflow connection on the tank. NOTE The deaerator drain and overflow lines (run independently or tied together) typically contain water at >230o F (110o C) and must be routed to a blowdown tank discharge piping at a point prior to the temperature valve sensor. Condensate Most deaerators have a high and low pressure condensate return connection. The high Returns pressure condensate return connection is where all system condensate return and separator trap discharge is introduced. Low pressure returns are typically pumped from a & condensate collection tank to the low pressure return connection. The high pressure condensate return connection(s) is located below the water line with a sparger tube Sparger Tube installed internally. Introducing the steam and hot condensate below the water line in conjunction with using the sparger tube reduces the velocity and turbulence created at the injection point, while minimizing flash steam losses and noise. In all cases a check valve must be installed, as close to the D/A as possible, in the separator trap discharge and condensate return lines to prevent back-feeding. When installing a Sparger Tube(s) it must be installed so that the holes are in a horizontal position. Pressure Steam is injected into the high pressure side of the tank to maintain the desired operating Regulating Valve pressure. A Pressure Regulating Valve (PRV) is used for pressure regulation. Safety Relief Each deaerator is equipped with a safety relief valve to prevent overpressurizing of the Valve tank. This valve is typically rated at 50 psi. The safety relief valve must discharge to atmosphere and in a direction that will not cause harm to personnel or equipment. The discharge piping must not contain any valves or other obstructions that could hinder the release of steam. Back Pressure A back pressure regulator is used to help maintain a steady operating pressure in the D/A. Regulation This valve is set below the safety valves and will vent during minor periods of over Valve pressurization. NOTE BPR sensing line must be plumbed directly to D/A pressure sensing port at the gauge connection on top of the D/A tank. 04/22/2015 3-7 Sect03_FeedwtrSys_xx4_f.fm STEAM GENERATOR & FLUID HEATER INSTALLATION MANUAL 3.6 SEMI-CLOSED RECEIVER (SCR) Semi-closed receiver systems are used only in applications that return a large amount (typically > 50%) of high pressure, high temperature, condensate. The SCR is a pressurized vessel that is maintained at a pressure that will minimize venting (wasting) of the excess system heat contained in the hot condensate returns. Feedwater outlet line sizing is critical. See Section 2.11. Each semi-closed receiver system is unique and requires individual attention to ensure proper application, installation and operation. Due to the nature and selected use of semi-closed receiver systems, they are addressed in supplemental instructions. 3.7 SEMI-CLOSED RECEIVER SKIDS These skids must be shipped with the SCR tank loose. Tank and interconnecting piping must be assembled by the installer. 3.8 HEAD TANK A 10-gallon head tank is required when proper receiver tank elevation is unavailable. A head tank provides the necessary positive coil feed pressure during wet layup. The tank must be installed at least two (2) feet above the steam generator coil inlet connection. Sect03_FeedwtrSys_xx4_f.fm 3-8 04/22/2015 SECTION IV - FUEL SYSTEM 4.1 GENERAL Clayton steam generators are designed to fire on natural gas, propane, or fuel oils (ranging from No. 2 distillate light oil to No. 6 residual heavy oil). A standard combination burner is designed to support both gas and oil firing. This burner can remain installed when switching between gas and oil firing. Characteristics of, and installation guidelines for, both gas and oil fuel systems are described in detail in the following paragraphs. NOTE The installing contractors are responsible for ensuring that all piping and fittings are rated for the intended system installation (material type, thickness, pressure, temperature). The installing contractors are also responsible for ensuring the steam system design meets the flow and pressure requirements of a Clayton steam generator (see Section VI, Table 1). 4.2 NATURAL GAS The Clayton gas train on modulating steam generators is designed and built in accordance with UL (Underwriters Laboratories), IRI (Industrial Risk Insurers), and FM (Factory Mutual) guidelines. It consists of a “double block-and-bleed” valve arrangement with proof-of-closure switches in both safety shut off gas valves. High and low gas pressure switches (with manual reset) are also provided. Unless otherwise stated (liquid petroleum and other gas operation requires engineering evaluation), the standard Clayton gas burner is designed for operation using pipe line quality natural gas. Gas supply connection sizes and rated gas flows for each model are provided in Tables 1and 2 of Section VI. The gas supply line must be sized to provide both the supply pressure and full rated flow indicated in Table 1 of Section VI without “sagging” (pressure drop). The gas supply pressure must not vary more than + 5% of Clayton’s required supply pressure. All gas supply connections must include a 12-inch drip leg immediately before the gas train. Pressure regulation is required if supply pressures are expected to exceed the 10 psi (0.69 bar) supply pressure limit. Regulators should be sized to pass 25% excess gas at full open position with minimal pressure drop. 04/22/2015 4-1 Sect04_FuelSys_xx4_f.fm STEAM GENERATOR & FLUID HEATER INSTALLATION MANUAL Vent lines are required for both the high and low gas pressure switches (1/8 inch) and vent valve (size varies with model - see generator P & ID drawing by specific model number.) NOTE Some gas trains are ventless. But, when gas train vent lines exist, they must be vented to atmosphere. NOTE All gas supply piping must include a minimum 12-inch drip leg immediately before Clayton’s gas train connection, and be fully selfsupporting. 4.3 OIL 4.3.1 General Clayton modulating, oil-fired, steam generators are designed with air atomizing-type oil burners. Either instrument air or compressed air is used for oil atomization. This air supply must be free of contaminants and moisture; therefore, an in-line air dryer should be installed in the atomizing air supply line. Atomizing air supply pressure and flow requirements are provided in Table 1 of Section VI. The atomizing air supply connection size for all models is 1/2 inch. NOTE All Clayton liquid fuel systems require a fuel return line in addition to the fuel supply line. Clayton recommends fuel return lines have no isolation valve, or only valves with position open locking mechanisms. NOTE It is the customer’s responsibility to implement and meet state, local and EPA code requirements for fuel oil storage. 4.3.2 Light Oil The Clayton light oil burner is designed for operation with No. 2 fuel oil as defined by ASTM D 396 - Standard Specifications for Fuel Oils. A Table of Specifications indicating the limits of the light oil fuel constituents and characteristics is provided, refer to Document R-8751 (Heavy Oil Specifications) at the end of Supplement III of this manual. NOTE A fusible-link-actuated shutoff valve is required in the fuel oil supply line when a machine is installed within FM (Factory Mutual) jurisdiction. This is not within the Clayton scope of supply and must be provided by the installing party. Sect04_FuelSys_xx4_f.fm 4-2 04/22/2015 Section IV The Clayton light oil burner can be furnished with either a light oil (No. 2) or gas pilot system. Gas pilot is supplied as standard equipment. The gas pilot fuel can be either natural gas or LPG. Clayton step-fired fuel systems uses a direct-fire ignition. 4.3.3 Heavy Oil Heavy oil operation requires special consideration with regard to storage, handling, maintenance, and proper operation. Supplemental Instructions pertaining to heavy oil operation have been developed for each model and should be used as guidelines for heavy oil applications, refer to Supplement II for an overview of heavy oil installations. 04/22/2015 4-3 Sect04_FuelSys_xx4_f.fm STEAM GENERATOR & FLUID HEATER INSTALLATION MANUAL (This page intentionally left blank.) Sect04_FuelSys_xx4_f.fm 4-4 04/22/2015 SECTION V - TRAP SEPARATORS 5.1 GENERAL Clayton steam generators require the same basic boiler feedwater treatment as any other watertube or firetube boiler. All require soft water with little or no dissolved oxygen, a sludge conditioner, and a moderate to high pH. The water supplied from the condensate receiver should meet these conditions. The primary distinction between a Clayton steam generator and drum type boiler is how and where the desired pH levels are achieved. The feedwater in the Feedwater Receiver is boiler water for the Clayton but similar to makeup water for the drum type boiler. Conventional boilers concentrate the boiler feedwater in the drum and maintain Total Dissolved Solids (TDS) levels and pH through blowdown. A system consisting of only Clayton steam generators uses the Feedwater Receiver much the same way conventional boilers use drums except that blowdown is taken off the separator trap discharge. Typically, drum type boilers cannot tolerate the higher pH levels that must be maintained in the feedwater receiver to satisfy Clayton feedwater requirements. Both systems work well independently, however feedwater chemical treatment problems arise when the two are operated in tandem with a common feedwater receiver - Clayton(s) with conventional boiler(s). The Clayton trap separator was designed to remedy the boiler compatibility problem. Using a trap separator allows both the Clayton(s) and conventional boiler(s) to operate together while sharing the same feedwater receiver. Each system receives feedwater properly treated to suit its respective operating requirements. If a trap separator is not used, pH is either too high for the conventional boiler(s) or too low for the Clayton(s). 5.2 OPERATION The separator trap returns from the Clayton steam generator(s) contain a high concentration of TDS. This high concentration of TDS is undesirable to conventional boilers because the blowdown rate would have to be increased (and could not be increased enough if the feedwater TDS level was over 3000 ppm). By routing the separator trap returns to the trap separator, rather than to the common feedwater receiver, the high concentration of TDS in the trap returns is isolated to the Clayton system. This not only eliminates the conventional boiler blowdown problems, but also satisfies the higher pH requirement of the Clayton(s) feedwater. The construction of a trap separator is very similar to that of a blowdown tank. Separator trap return enters tangentially creating a swirling action. Flash steam is vented out the top and low pressure condensate is fed to the booster pump(s) from the outlet. 04/22/2015 5-1 Sect05_TrapSeparator_e.fm STEAM GENERATOR & FLUID HEATER INSTALLATION MANUAL This relatively small amount of concentrated water blends with the larger volume of less concentrated feedwater being supplied from the feedwater receiver (ideally, the chemical treatment for both systems is injected into the feedwater receiver) to produce a mixture of properly treated feedwater entering the Clayton heating coil(s). The other boiler(s) receive feedwater containing the pH and TDS levels they require. 5.3 INSTALLATION (Refer to Figures 5-1, 5-2, and 5-3.) 5.3.1 General As shown in Figures 5-3, three sizes of trap separators have been designed to handle a broad range of boiler horsepowers. Typical dimensions for each trap separator are provided in Figure 3. Line sizes for the trap separator connections are provided and should be kept full size (no reductions). The trap separator and connected piping must be properly supported. The trap separator is maintained at the same pressure and water level as the feedwater receiver and should be installed at an elevation that puts the water level midpoint in the sight glass. 5.3.2 Trap Separator Vent The trap separator vent line must be large enough to handle the flash steam with little or no pressure drop and without affecting the water level. Proper vent line sizes for specific horsepower ranges are indicated in Figures 5-1 and 5-2 and must not be reduced. On Deaerator (D/A) applications the vent flash steam should be introduced into the same section of the Deaerator as the Pressure Regulating Valve (PRV) steam injection. On open system applications, the vent line should be introduced to the top of the feedwater receiver. Refer to Figure 5-1. The trap separator outlet is tied into the booster pump(s) feedwater supply line from the common feedwater receiver. The outlet piping should be constructed so as to provide the required NPSH to the booster pump(s) inlet. (any frictional loss subtracts from the available NPSH). The outlet piping should contain a minimum number of elbows and fittings, and no valves or check valves. 5.3.3 Feedwater Receiver Supply Lines Provisions should be made for the feedwater receiver to have independent feed lines for the Clayton and conventional boiler feedwater supply. If not isolated, there is a potential for the larger feedwater pumps of the conventional boiler system to draw the water out of the trap separator and away from the Clayton feedwater supply system. This disrupts the chemical treatment in both systems and may cause water shortage and pump cavitation problems in the Clayton system. If independent feed lines are not possible, a swing check valve must be installed in the feedwater supply line to prevent backflow away from the Clayton system. (Refer to Figure 5.1) Sect05_TrapSeparator_e.fm 5-2 04/22/2015 Section V R20202A Figure 5-1 Trap separator hookup with hotwell 04/22/2015 5-3 Sect05_TrapSeparator_e.fm STEAM GENERATOR & FLUID HEATER INSTALLATION MANUAL R20202A Figure 5-2 Trap separator hookup with deaerator Sect05_TrapSeparator_e.fm 5-4 04/22/2015 Section V R20202A Figure 5-3 Trap separator dimensions 04/22/2015 5-5 Sect05_TrapSeparator_e.fm STEAM GENERATOR & FLUID HEATER INSTALLATION MANUAL (This page intentionally left blank.) Sect05_TrapSeparator_e.fm 5-6 04/22/2015 SECTION VI - TECHNICAL SPECIFICATIONS 6.1 GENERAL The following pages contain Tables with general reference information intended to assist in the installation of your Clayton steam generator. The information is provided only for standard Clayton thermal products. Specially designed equipment, such as Clayton steam generators with Low NOx burners, are excluded from these Tables, but are addressed in Supplemental Instructions. 6.2 AGENCY APPROVALS All standard modulating Clayton steam generators are designed and built to meet ANSI, ASME, Boiler Pressure Vessel Code Section I, ASME CSD-1, IRI, FM, and UL requirements. The marine listings ABS, USCG, DNV, and CCG, are available. 6.3 CONSTRUCTION MATERIALS Only high quality materials are used in the manufacturing of the Clayton steam generator. The heating coil in the generator is manufactured by Clayton using ASME SA178 steel tubing. All welds are performed by Clayton ASME certified welders and stress relieved. The coil is then hydrostatically tested to 1.5 times the design pressure or 750 psig (52 bars) which ever is greater. The coil is encased in a mild steel jacket that contains all combustion gases. The steam separator shell is constructed of SA53 seamless black pipe. The heads are made of ASME SA 285 carbon steel. The separator also has openings for steam safety relief valves. 6.4 FLAME SAFEGUARD Burner flame control is managed by the Electronic Safety Control (ESC). The ESC is a microprocessor-based burner management system designed to control and supervise forced draft burners. It provides a proven burner purge period prior to each firing sequence. This control monitors both pilot and main flames. It cycles automatically each time the operating pressure setpoint is achieved. In the event of a flame failure during a firing cycle, all fuel valves are de-energized. The ESC will then lock out and total burner shutdown will be indicated on the display and operating unit. Before the burner can be started again, a manual reset of the ESC is required. The ESC has a safety checking circuit that is operative on each start. If a flame is detected prior to a firing sequence or during the purge period, the burner controls will not energize. Total safety shutdown will occur requiring a manual reset of the ESC. Operating and programming of the ESC, diagnosis of burner operations, and readouts of ESC settings and operating states are executed from a display and operating unit, which is mounted on the right-hand door to the electrical control box. The display and operating unit features a 4 x 16 character LCD display, 4 silicon user buttons, and communication ports for external device interfacing. 04/22/2015 6-1 Sect06_TechSpecs_xx4_L.fm Steam Generator and Fluid Heater Installation Manual 6.5 SAFETY CONTROLS In addition to the combustion safety control, the following safety devices are continuously monitored during the steam generator operation. 6.5.1 Temperature Control Devices There are three temperature control devices that continuously monitor the machine. The first device monitors the temperature of the steam to prevent against a superheat condition. The second and third temperature devices are a dual element thermocouple that provides continuous monitoring of the coil face temperature in the combustion chamber. 6.5.2 Regulator Approvals Fuel systems are designed to comply with Underwriters Laboratory (UL) and FM approval with IRI available. 6.5.3 Steam Limit Pressure Switch A steam limit pressure switch protects against an over-pressure condition. 6.5.4 Combustion Air Pressure Switch A combustion air pressure switch is used to prove that sufficient air is present for proper combustion. 6.5.5 Atomizing Oil Nozzles Modulating oil units use air atomizing oil nozzles, atomizing air customer supplied. Stepfired models use pressure atomizing oil nozzles, no pressurized air supply required. 6.5.6 Pump Oil Level Switch A switch is available that monitors the Clayton feedwater pump crankcase oil level for both a high and low oil level condition. 6.5.7 Overcurrent Protection The electrical circuits (primary and secondary) and all motors are protected against an overcurrent condition. 6.6 EQUIPMENT SPECIFICATIONS Sect06_TechSpecs_xx4_L.fm 6-2 04/22/2015 04/22/2015 5,175 15–500 12–450 Design pressure (psi) Steam operating pressure (psi) 6,695,000 6-3 57 55 F1. Oil consumption w/o SE (gph) 41 F2. Oil consumption w/ SE (gph) 41 a Values shown are nominal and are not guaranteed. 473 18 473 18 Exhaust Stack diameter (in.) Heating surface (sq. ft.) 6 Area of free air intake (sq. ft.) 4.5 25 1,065 70 795 H. Water supply (gph) 5–10 7,876 flow (scfm) 25 5–10 G3. Gas supply pressure (psi) Atomizing air (oil-fired only): pressure (psi) 70 5,907 SE (ft3/hr) G2. Natural gas consumption w/ SE (ft3/hr) 8,167 40 6,050 35 7 1/2 10 84/87 82/85 12–450 15–500 FGR/LNOx 35 G1. Natural gas consumption w/o E-204 6,900 E. Full load amperage (at 460 V) (up to -3 design): standard 25 Feedwater pump(s) (hp) 5 Blower (hp) 7 1/2 D. Motor sizes (up to -3 design) C. Thermal efficiencies at 100% firing rate (%): Oil (without SE/SE) 85/87 Gas (without SE/SE) 83/85 5,021,250 B. Gross steam output (lb/hr) E-154 473 24 7.5 25 70 1,325 5–10 9,846 10,206 68 71 40 40 10 10 84/87 82/85 12–450 15–500 8,625 8,368,750 E-254 594 24 9 25 70 1,590 5–10 11,815 12,247 82 85 50 45 10 10 84/87 82/85 12–450 15–500 10,350 10,042,500 E-304 594 24 10.5 25 70 1,855 5–10 13,784 14,288 96 99 80 70 15 25 84/87 82/85 12–450 15–500 12,075 11,716,250 E-354 912 32 12 30 70 2,120 5–10 15,753 16,329 110 115 80 70 15 20 83/87 82/85 60–450 65–500 13,800 13,390,000 E-404 912 32 15 30 70 2,651 5–10 19,691 20,412 138 143 90 80 20 25 83/86 82/85 60–450 65–500 17,250 16,737,500 E-504 1,230 32 18 30 70 3,181 5–10 23,629 24,199 164 168 125 110 30 40 85/87 83/85 60–450 65–500 20,700 20,085,000 E-604 1,522 36 21 30 70–100 3,711 5–10 27,885 28,588 193.8 198.5 160 145 40 50 84/86 82/84 60–450 65–500 24,150 23,432,500 E-704 2,806.8 45 30 50 100 5,302 5–10 39,382 40,824 280 290 287 277 100 75 84/87 83/85 60–450 65–500 34,500 33,475,000 E-1004 n/a 45 30 50 100 n/a 5–10 42,324 43,837 301 312 n/a n/a n/a n/a 84/87 83/85 60–450 65–500 37,950 36,822,500 E-1104 6.6.1 A. Net heat output (Btu/hr) SPECS MODEL Table 6-1a Section VI - Technical Specifications Modulating Generators Sect06_TechSpecs_xx4_L.fm Steam Generator and Fluid Heater Installation Manual 6.6.2 Table 6-1 Supplemental Information NOTE All values are rated at maximum continuous firing rate. A. Net heat output is calculated by multiplying boiler horsepower by 33,475 Btu/hr. Net heat input can be calculated by dividing net heat output by the rated efficiency. B. Gross steam output, from and at 212o F, is calculated by multiplying boiler horsepower by 34.5 lb/ hr. C. Thermal efficiencies are based on high heat or gross caloric (Btu) values of the fuel. Efficiencies shown are nominal. Small variations may occur due to manufacturing tolerances. Consult factory for guaranteed values. D. Consult factory for motor horsepowers for Units with design pressures above 300 psi. E. Except where noted, indicated full load amperage (FLA) is for 460 VAC primary voltage supply. See paragraph 2.12, Section II, to obtain FLA for other voltages. Consult factory for FLA for Units with design pressures above 300 psi. F. Oil consumption based on 140,600 Btu/gal. of commercial standard grade No. 2 oil (ASTM D396). Oil Consumption = 100 ( 33,475bhpBtu/hr) (bhp) (efficiency )( 1 gal. 140,600 Btu ) G. Natural Gas consumption based on 1000 Btu/ft3 gas. Use the following formula to determine gas consumption for gases with other heat values: Gas Consumption = 100 (33,475bhpBtu/hr) (bhp) (efficiency )( 1 ft3 1,000 Btu ) H. Water supply is based on 44 lb/hr per boiler horsepower. 6.7 EQUIPMENT LAYOUT AND DIMENSIONS NOTE The steam generator layouts and dimensions given in this section are approximate. The illustration in each figure is a general outline that depicts multiple steam generator models. Refer to the corresponding tables that follow each figure for the specific steam generator model dimensions. Sect06_TechSpecs_xx4_L.fm 6-4 04/22/2015 Section VI - Technical Specifications 6.7.1 Modulating Steam Generators Figure 6-1 Equipment layout for E154–E604 modulating steam generators 04/22/2015 6-5 Sect06_TechSpecs_xx4_L.fm Steam Generator and Fluid Heater Installation Manual Table 6-2: Equipment layout and dimensions for E154–E254 modulating steam generators (refer to Figure 6-1 for layout and item callouts) Model: Layout & Dimensions Item A B B1 C C C1 D D OW OL E F G H I J K L M N O O1 P Q R S T1 T2 U V W X Y Z AA AB AC Connection Sizes & Types Approximate Shipping Weights Sect06_TechSpecs_xx4_L.fm E-154 Specification Generator width; in. (cm) Generator length (gas); in. (cm) Pump length; in. (cm) Generator height, w/o SE; in. (cm) Generator height, w/ SE; in. (cm) Pump height; in. (cm) Coil removal height, w/o SE; in. (cm) Coil removal height, w/ SE; in. (cm) Overall generator width; in. (cm) Overall generator length (gas); in. (cm) Frame mounting, generator; in. (cm) Frame mounting, generator; in. (cm) Frame mounting, generator; in. (cm) Frame mounting, generator; in. (cm) Frame mounting, pump to generator; in. (cm) Frame mounting, pump; in. (cm) Frame mounting, pump; in. (cm) Frame mounting, pump to generator; in. (cm) Steam outlet; in. (cm) Steam outlet; in. (cm) Steam outlet; in. (cm) Steam outlet, w/ sootblow; in. (cm) Feedwater inlet; in. (cm) Feedwater inlet; in. (cm) Feedwater inlet; in. (cm) Flue diameter, o.d.; in. (cm) Air inlet connection; in. (cm) Air inlet connection; in. (cm) Leg height; in. (cm) Main Gas inlet; in. (cm) Gas inlet; in. (cm) Gas inlet; in. (cm) Oil inlet; in. (cm) Oil return; in. (cm) Oil inlet; in. (cm) Oil return; in. (cm) Gravity fill; in. (cm) Feedwater inlet (FPT); in. Separator discharge outlet (300# R. F. flng); in. Separator drain (FPT); in. Steam Trap discharge outlet (FPT); in. Coil blowdown drain, w/o SE (FPT); in. Coil blowdown drain, w/ SE (FPT); in. Coil gravity drain (FPT); in. Upper waterwall drain, SE only; in. Pilot gas inlet (FPT); in. Main gas inlet (FPT); in. Fuel oil inlet (FPT); in. Fuel oil return (FPT); in. Atomizing Air Inlet-oil units (FPT); in. Gravity fill inlet (FPT); in. Sootblow connection (MPT); in. Safety Valve outlet Generator shipping weight w/o SE; lb (kg) Generator shipping weight w/ SE; lb (kg) Pump shipping weight; lb (kg) 6-6 E-204 E-254 61.25 (155.58) 61.25 (155.58) 61.25 (155.58) 98.63 (250.52) 98.63 (250.52) 98.63 (250.52) 39.74 (100.94) 39.74 (100.94) 41.72 (105.97) 101.88 (258.78) 101.88 (258.78) 101.88 (258.78) 120.75 (306.71) 120.75 (306.71) 120.75 (306.71) 52.43 (133.17) 52.43 (133.17) 55.72 (141.53) 109 (276.86) 109 (276.86) 109 (276.86) 128 (325.12) 128 (325.12) 128 (325.12) 92.75 (235.59) 92.75 (235.59) 103.13 (261.95) 114.38 (290.53) 114.38 (290.53) 114.38 (290.53) 26.88 (68.28) 26.88 (68.28) 26.88 (68.28) 60.56 (153.82) 60.56 (153.82) 60.56 (153.82) 53.88 (136.86) 53.88 (136.86) 53.88 (136.86) 26.88 (68.28) 26.88 (68.28) 26.88 (68.28) 7.88 (20.02) 7.88 (20.02) 9 (22.86) 9 (22.86) 9 (22.86) 14.75 (37.47) 31.5 (80.01) 31.5 (80.01) 30.5 (77.47) 16 (40.64) 16 (40.64) 16.5 (41.91) 35.63 (90.5) 35.63 (90.5) 35.63 (90.5) 4.13 (10.49) 4.13 (10.49) 4.13 (10.49) 91.88 (233.38) 91.88 (233.38) 91.88 (233.38) 105.75 (268.61) 105.75 (268.61) 105.75 (268.61) 24.25 (61.6) 24.25 (61.6) 27.63 (70.18) 46.88 (119.08) 46.88 (119.08) 43.5 (110.49) 25.75 (65.41) 25.75 (65.41) 36 (91.44) 17.88 (45.42) 17.88 (45.42) 23.88 (60.66) 24.44 (62.08) 24.44 (62.08) 24.44 (62.08) 20.13 (51.13) 20.13 (51.13) 20.13 (51.13) 15 (38.1) 15 (38.1) 15 (38.1) 23.38 (59.39) 23.38 (59.39) 23.38 (59.39) 1.25 (3.18) 1.25 (3.18) 1.25 (3.18) 5.5 (13.97) 5.5 (13.97) 5.5 (13.97) 37.88 (96.22) 37.88 (96.22) 37.88 (96.22) 41 (104.14) 41 (104.14) 41 (104.14) 20.5 (52.07) 20.5 (52.07) 20.5 (52.07) 34.5 (87.63) 34.5 (87.63) 34.5 (87.63) 95.63 (242.9) 95.63 (242.9) 95.63 (242.9) 2 2 2 4 4 4 1-1/2 1-1/2 1-1/2 1 1-1/4 1-1/4 1-1/2 1-1/2 1-1/2 1-1/4 1-1/4 1-1/4 2-1/2 2-1/2 2-1/2 1-1/4 1-1/4 1-1/4 1/2 1/2 1/2 1 1-1/2 1-1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 1-1/2 1-1/2 1-1/2 See Plan Installation Drawing for Relief Valve connections. 7,390 (3,352) 7,410 (3,361) 7,410 (3,361) 8,360 (3,792) 8,390 (3,806) 8,390 (3,806) 850 (386) 1,050 (476) 1,050 (476) 04/22/2015 Section VI - Technical Specifications Table 6-2: Equipment layout and dimensions for E304–E354 modulating Steam Generators (refer to Figure 6-1 for layout and item callouts) Model: Item A B B1 C C1 D Layout & Dimensions Connection Sizes & Types Approximate Shipping Weights 04/22/2015 OW OL E F G H I J K L M N O O1 P Q R S T1 T2 U V W X Y Z AA AB AC E-304 Specification Generator width; in. (cm) Generator length (gas); in. (cm) Pump length; in. (cm) Generator height, w/o SE; in. (cm) Generator height, w/ SE; in. (cm) Pump height; in. (cm) Coil removal height, w/o SE; in. (cm) Coil removal height, w/ SE; in. (cm) Overall generator width; in. (cm) Overall generator length (gas); in. (cm) Frame mounting, generator; in. (cm) Frame mounting, generator; in. (cm) Frame mounting, generator; in. (cm) Frame mounting, generator; in. (cm) Frame mounting, pump to generator; in. (cm) Frame mounting, pump; in. (cm) Frame mounting, pump; in. (cm) Frame mounting, pump to generator; in. (cm) Steam outlet; in. (cm) Steam outlet; in. (cm) Steam outlet; in. (cm) Steam outlet, w/ sootblow; in. (cm) Feedwater inlet; in. (cm) Feedwater inlet; in. (cm) Feedwater inlet; in. (cm) Flue diameter, o.d.; in. (cm) Air inlet connection; in. (cm) Air inlet connection; in. (cm) Leg height; in. (cm) Main Gas inlet; in. (cm) Gas inlet; in. (cm) Gas inlet; in. (cm) Oil inlet; in. (cm) Oil return; in. (cm) Oil inlet; in. (cm) Oil return; in. (cm) Gravity fill; in. (cm) Feedwater inlet (FPT); in. Separator discharge outlet; in. Separator drain (FPT); in. Steam Trap discharge outlet (FPT); in. Coil blowdown drain, w/o SE (FPT); in. Coil blowdown drain, w/ SE (FPT); in. Coil gravity drain (FPT); in. Upper waterwall drain, SE only; in. Pilot gas inlet (FPT); in. Main gas inlet (MPT); in. Fuel oil inlet (FPT); in. Fuel oil return (FPT); in. Atomizing Air Inlet-Oil Units (FPT); in. Gravity fill inlet (FPT); in. Sootblow connection-Oil Units (MPT); in. Safety Valve outlet Generator shipping weight w/o SE; lb (kg) Generator shipping weight w/ SE; lb (kg) Pump shipping weight; lb (kg) 6-7 E-354 61.25 (155.58) 61.25 (155.58) 93.63 (237.82) 93.63 (237.82) 41.72 (105.97) 41.72 (105.97) 114.38 (290.53) 114.38 (290.53) 137 (347.98) 137 (347.98) 55.72 (141.53) 55.72 (141.53) 121.75 (309.25) 121.75 (309.25) 144.38 (366.73) 144.38 (366.73) 103.13 (261.95) 103.13 (261.95) 113.5 (288.29) 113.5 (288.29) 26.88 (68.28) 26.88 (68.28) 60.56 (153.82) 60.56 (153.82) 53.88 (136.86) 53.88 (136.86) 26.88 (68.28) 26.88 (68.28) 9 (22.86) 9 (22.86) 14.75 (37.47) 14.75 (37.47) 30.5 (77.47) 30.5 (77.47) 16.63 (42.24) 16.63 (42.24) 30.75 (78.11) 30.75 (78.11) 4.13 (10.49) 4.13 (10.49) 98.38 (249.89) 98.38 (249.89) 112.25 (285.12) 112.25 (285.12) 27.63 (70.18) 27.63 (70.18) 43.5 (110.49) 43.5 (110.49) 36 (91.44) 36 (91.44) 23.88 (60.66) 23.88 (60.66) 24.31 (61.75) 24.31 (61.75) 21.04 (53.44) 21.04 (53.44) 15 (38.1) 15 (38.1) 23.38 (59.39) 23.38 (59.39) 1.75 (4.45) 1.75 (4.45) 5.5 (13.97) 5.5 (13.97) 37.88 (96.22) 37.88 (96.22) 41 (104.14) 41 (104.14) 15.5 (39.37) 15.5 (39.37) 29.5 (74.93) 29.5 (74.93) 103 (261.62) 103 (261.62) 2 2 4 (300# R.F. flng.) 4 (300# R.F. flng.) 1-1/2 1-1/2 1-1/4 1-1/2 1-1/2 1-1/2 1-1/4 1-1/4 2-1/2 2-1/2 1-1/4 1-1/4 1/2 1/2 1-1/2 1-1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 1-1/2 1-1/2 See Plan Installation Drawing for Relief Valve connections. 9,140 (4,146) 9,140 (4,146) 10,530 (4,776) 10,530 (4,776) 1,150 (522) 1,150 (522) Sect06_TechSpecs_xx4_L.fm Steam Generator and Fluid Heater Installation Manual Table 6-2: Equipment layout and dimensions for E404–E604 modulating Steam Generators (refer to Figure 6-1 for layout and item callouts) Model: Item A B B1 C C1 D OW Layout OL E F G H I I1 J J1 J2 K & Dimensions K1 K2 L M N O O1 P Q R S T1 T2 U V W X Y Z AA AB AC Connection Sizes & Types E-404 Specification Generator width; in. (cm) Generator length (EG/EOG); in. (cm) Pump length, single J4; in. (cm) Pump length, dual J4; in. (cm) Generator height, w/o SE; in. (cm) Generator height, w/ SE; in. (cm) Pump height, single J4; in. (cm) Pump height, dual J4; in. (cm) Coil removal height, w/o SE; in. (cm) Coil removal height, w/ SE; in. (cm) Overall generator width, single J4; in. (cm) Overall generator width, dual J4; in. (cm) Overall generator length (gas); in. (cm) Frame mounting, generator; in. (cm) Frame mounting, generator; in. (cm) Frame mounting, generator; in. (cm) Frame mounting, generator; in. (cm) Frame mounting, pump to generator; in. (cm) Frame mounting, pump to generator; in. (cm) Frame mounting, pump; in. (cm) Frame mounting, pump; in. (cm) Frame mounting, pump; in. (cm) Frame mounting, pump, single J4; in. (cm) Frame mounting, pump, dual J4; in. (cm) Frame mounting, pump, dual J4; in. (cm) Frame mounting, pump, dual J4; in. (cm) Frame mounting, pump to generator; in. (cm) Steam outlet; in. (cm) Steam outlet; in. (cm) Steam outlet; in. (cm) Steam outlet, w/ sootblow (EO/EOG); in. (cm) Feedwater inlet; in. (cm) Feedwater inlet, single J4; in. (cm) Feedwater inlet, dual J4; in. (cm) Feedwater inlet, single J4; in. (cm) Feedwater inlet, dual J4; in. (cm) Flue diameter, o.d.; in. (cm) Air inlet connection; in. (cm) Air inlet connection; in. (cm) Leg height; in. (cm) Main gas inlet; in. (cm) Gas inlet; in. (cm) Gas inlet; in. (cm) Oil inlet; in. (cm) Oil return; in. (cm) Oil inlet; in. (cm) Oil return; in. (cm) Gravity fill; in. (cm) Feedwater inlet (FPT), dual J4; in. Separator discharge outlet (300# R. F. flng); in. Separator drain (FPT); in. Steam Trap discharge outlet (FPT); in. Coil blowdown drain, w/o SE (FPT); in. Coil blowdown drain, w/ SE (FPT); in. Coil gravity drain (FPT); in. Upper waterwall drain (FPT), SE only; in. Pilot gas inlet (FPT); in. Sect06_TechSpecs_xx4_L.fm 6-8 68.75 (174.63) 117.38 (298.15) 41.72 (106) 59.26 (150.52) 130.75 (332.11) 156.25 (396.88) 55.72 61.86 (157.12) 134.5 (341.63) 164.5 (417.83) 104 (264.16) 130.63 (331.8) 133.13 (338.15) 32.13 (81.61) 62 (157.48) 64.25 (163.2) 32.13 (81.61) 21 (53.34) 10.38 (26.37) 14.75 (37.47) 7.38 (18.75) 30.5 (77.47) 30.5 (77.47) 41.38 (105.11) 14.75 (37.47) 12 (30.48) 16.63 (42.24) 30.69 (77.95) 9 (22.86) 118.25 (300.36) 134.37 (341.3) 27.5 (69.85) 55.5 (140.97) 54.63 (138.76) 35.75 (90.81) 64.25 (163.2) 31.75 (80.65) 24.31 (61.75) 21.04 (53.44) 13 (33.02) 25.25 (64.14) 2.25 (5.72) 8.38 (21.29) 38.88 (98.76) 42 (106.68) 26 (66.04) 37.38 (94.95) 126.13 (320.37) 2x3 6 1-1/2 1-1/2 1-1/2 1-1/2 2-1/2 1-1/2 1/2 E-504 68.75 (174.63) 117.25 (298.15) na 59.26 (150.52) 130.75 (332.11) 156.25 (396.88) na 61.86 (157.12) 134.5 (341.63) 164.5 na 130.63 (331.8) 133.13 (338.15) 32.13 (81.61) 62 (157.48) 64.25 (163.2) 32.13 (81.61) na 10.38 (26.37) na 7.38 (18.75) 30.5 (77.47) na 41.38 (105.11) 14.75 (37.47) 12 (30.48) 18 (45.72) 30.69 (77.95) 9 (22.86) 118.25 (300.36) 134.37 (341.3) 27.5 (69.85) na 54.63 (138.76) na 64.25 (163.2) 31.75 (80.65) 24.31 (61.75) 21.04 (53.44) 13 (33.02) 25.25 (64.14) 2.25 (5.72) 8.38 (21.29) 38.88 (98.76) 42 (106.68) 26 (66.04) 37.38 (94.95) 126.13 (320.37) 2x3 6 1-1/2 1-1/2 1-1/2 1-1/2 2-1/2 1-1/2 1/2 E-604 68.75 (174.63) 117.25 (298.15) na 59.26 (150.52) 180.5 (458.47) na na 61.86 (157.12) 188.75 (479.43) na na 130.63 (331.8) 133.13 (338.15) 32.13 (81.61) 62 (157.48) 64.25 (163.2) 32.13 (81.61) na 10.38 (26.37) na 7.38 (18.75) 30.5 (77.47) na 41.38 (105.11) 14.75 (37.47) 12 (30.48) 18 (45.72) 30.75 (78.11) 9.13 (23.19) 118.25 (300.36) 134.37 (341.3) 27.5 (69.85) na 54.63 (138.76) na 64.25 (163.2) 31.75 (80.65) 24.31 (61.75) 21.04 (53.44) 13 (33.02) 25.25 (64.14) 2.25 (5.72) 8.38 (21.29) 38.88 (98.76) 42 (106.68) 26 (66.04) 37.38 (94.95) 142.13 (361.01) 2x3 6 1-1/2 1-1/2 1-1/2 1-1/2 2-1/2 1-1/2 1/2 04/22/2015 Section VI - Technical Specifications Table 6-2: Equipment layout and dimensions for E404–E604 modulating Steam Generators (refer to Figure 6-1 for layout and item callouts) Model: Connection Sizes & Types Approximate Shipping Weights 04/22/2015 E-404 Main gas inlet (MPT); in. Fuel oil inlet (FPT); in. Fuel oil return (FPT); in. Atomizing Air Inlet-Oil Units (FPT); in. Gravity fill inlet (FPT); in. Sootblow connection-Oil Units (MPT); in. Safety Valve outlet Generator shipping weight w/o SE; lb (kg) Generator shipping weight w/ SE; lb (kg) Pump shipping weight; lb (kg) 6-9 E-504 E-604 2 2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 2-1/2 2-1/2 See Plan Installation Drawing for Relief 14,650 (6,645) 14,790 (6,709) 17,040 (7,729) 17,190 (7,797) 1,970 (894) 2,000 (907) 2 1/2 1/2 1/2 3/4 2-1/2 Valve connections. 17,980 (8,156) na 2,200 (998) Sect06_TechSpecs_xx4_L.fm Steam Generator and Fluid Heater Installation Manual I (2x) K X Q J (2x) M L (2x) R G (3x) OW N W H2 T1 H1 E (2x) F (2x) T2 oS Q M OL STANDARD R oS N OW T1 T2 W OL X FMB D C O1 O P V Y Z AA AB Figure 6-2 Equipment layout for E154–E354 flush-floor frame, modulating, steam generators Sect06_TechSpecs_xx4_L.fm 6-10 04/22/2015 Section VI - Technical Specifications Table 6-3: Equipment layout and dimensions for E154–E204FMB modulating steam generators with flush-floor frame (refer to Figure 6-2 on previous page for layout and item callouts) Model: Layout & Dimensions Connection Sizes & Types Approximate Shipping Weights 04/22/2015 Item C C D D OW OL E F G H1 H2 I J K L M N O O1 P Q R S T1 T2 V W X Y Z AA AB E-154 Specification Generator height, w/o SE; in. (cm) Generator height, w/ SE; in. (cm) Coil removal height, w/o SE; in. (cm) Coil removal height, w/ SE; in. (cm) Overall generator width; in. (cm) Overall generator length (gas); in. (cm) Frame mounting, generator; in. (cm) Frame mounting, generator; in. (cm) Frame mounting, generator; in. (cm) Frame mounting, generator; in. (cm) Frame mounting, generator; in. (cm) Frame mounting, pump to generator; in. (cm) Frame mounting, pump; in. (cm) Frame mounting, pump; in. (cm) Frame mounting, pump; in. (cm) Steam outlet; in. (cm) Steam outlet; in. (cm) Steam outlet; in. (cm) Steam outlet, w/ sootblow; in. (cm) Feedwater inlet; in. (cm) Feedwater inlet; in. (cm) Feedwater inlet; in. (cm) Flue diameter, o.d.; in. (cm) Air inlet connection; in. (cm) Air inlet connection; in. (cm) Main Gas inlet; in. (cm) Gas inlet; in. (cm) Gas inlet; in. (cm) Oil inlet; in. (cm) Oil return; in. (cm) Oil inlet; in. (cm) Oil return; in. (cm) Feedwater inlet (FPT); in. Separator discharge outlet (300# R. F. flng); in. Separator drain (FPT); in. Steam Trap discharge outlet (FPT); in. Coil blowdown drain, w/o SE (FPT); in. Coil blowdown drain, w/ SE (FPT); in. Coil gravity drain (FPT); in. Upper waterwall drain, SE only; in. Pilot gas inlet (FPT); in. Main gas inlet (FPT); in. Fuel oil inlet (FPT); in. Fuel oil return (FPT); in. Atomizing Air Inlet-oil units (FPT); in. Gravity fill inlet (FPT); in. Sootblow connection (MPT); in. Safety Valve outlet Generator shipping weight w/o SE; lb (kg) Generator shipping weight w/ SE; lb (kg) Pump shipping weight; lb (kg) 6-11 E-204 E-204FMB 102 (259) 102 (259) 120.75 (306.7) 120.75 (306.7) 109 (277) 109 (277) 127.5 (324) 127.5 (324) 96.38 (244.8) 96.38 (244.8) 112.5 (285.8) 112.5 (285.8) 26.88 (68.3) 26.88 (68.3) 56.63 (143.8) 56.63 (143.8) 53 (134.6) 53 (134.6) 6.88 (17.5) 6.88 (17.5) 2.5 (6.4) 2.5 (6.4) 6.88 (17.5) 6.88 (17.5) 17.88 (45.4) 17.88 (45.4) 33.88 (86) 33.88 (86) 12.38 (31.4) 12.38 (31.4) 40.63 (103.2) 40.63 (103.2) 4.38 (11) 4.38 (11) 89.5 (227.3) 89.5 (227.3) 103.5 (263) 103.5 (263) 28.75 (73) 28.75 (73) 63.13 (160.4) 63.13 (160.4) 63.13 (160.4) 63.13 (160.4) 18 (46) 18 (46) 25.75 (65.4) 25.75 (65.4) 21.25 (54.0) 21.25 (54.0) 24.38 (62) 24.38 (62) 57.63 (146.4) 57.63 (146.4) 105.88 (269) 105.88 (269) 16.5 (42) 16.5 (42) 19.75 (50.2) 19.75 (50.2) 23.38 (59.4) 23.38 (59.4) 33.75 (85.7) 33.75 (85.7) 2 3 4 4 1-1/2 1-1/2 1 1-1/4 1-1/2 1-1/2 1-1/4 1-1/4 2-1/2 2-1/2 1-1/4 1-1/4 1/2 1/2 1 1-1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 1-1/2 1-1/2 See Plan Installation Drawing for Relief 7,390 (3,352) 7,500 (3,402) 8,360 (3,792) 8,400 (3,810) 1,100 (499) 1,200 (545) 109.1 (277) 127.9 (325) 116 (294.6) 135 (343) 105.38 (267.7) 158.5 (402.6) 26.88 (68.3) 56.63 (143.8) 53 (134.6) 6.88 (17.5) 2.5 (6.4) 6.88 (17.5) 17.88 (45.4) 33.88 (86) 12.38 (31.4) 40.63 (103.2) 4.38 (11) 89.5 (227.3) 103.5 (263) 28.75 (73) 63.13 (160.4) 63.13 (160.4) 18 (46) 31.9 (81.0) 20.9 (53.0) 19.75 (50.2) 5.25 (13.3) 97.75 (248.3) N/A N/A N/A N/A 3 4 1-1/2 1-1/2 1-1/2 1-1/4 2-1/2 1-1/4 1/2 1-1/2 N/A N/A N/A 3/4 N/A Valve connections. 7,500 (3,402) 8,400 (3,810) 1,200 (545) Sect06_TechSpecs_xx4_L.fm Steam Generator and Fluid Heater Installation Manual Table 6-3: Equipment layout and dimensions for E254FMB–E304 modulating Steam Generators with flush-floor frame (refer to Figure 6-2 for layout and item callouts) Model: Layout & Dimensions Connection Sizes & Types Approximate Shipping Weights Item C C D D OW OL E F G H1 H2 I J K L M N O O1 P Q R S T1 T2 V W X Y Z AA AB E-254 E-254FMB Specification Generator height, w/o SE; in. (cm) 102 (259) 109.1 (277) Generator height, w/ SE; in. (cm) 120.75 (307) 127.9 (325) Coil removal height, w/o SE; in. (cm) 109 (277) 116 (294.6) Coil removal height, w/ SE; in. (cm) 127.5 (324) 135 (343) Overall generator width; in. (cm) 96.38 (244.8) 105.38 (267.7) Overall generator length (gas); in. (cm) 112.5 (285.8) 158.5 (402.6) Frame mounting, generator; in. (cm) 26.88 (68.3) 26.88 (68.3) Frame mounting, generator; in. (cm) 56.63 (143.8) 56.63 (143.8) Frame mounting, generator; in. (cm) 53 (134.6) 53 (134.6) Frame mounting, generator; in. (cm) 6.88 (17.5) 6.88 (17.5) Frame mounting, generator; in. (cm) 2.5 (6.4) 2.5 (6.4) Frame mounting, pump to generator; in. (cm) 6.88 (17.5) 6.88 (17.5) Frame mounting, pump; in. (cm) 17.88 (45.4) 17.88 (45.4) Frame mounting, pump; in. (cm) 33.88 (86) 33.88 (86) Frame mounting, pump; in. (cm) 12.38 (31.4) 12.38 (31.4) Steam outlet; in. (cm) 40.63 (103.2) 40.63 (103.2) Steam outlet; in. (cm) 4.38 (11) 4.38 (11) Steam outlet; in. (cm) 89.5 (227.3) 89.5 (227.3) Steam outlet, w/ sootblow; in. (cm) 103.5 (263) 103.5 (263) Feedwater inlet; in. (cm) 28.75 (73) 28.75 (73) Feedwater inlet; in. (cm) 63.13 (160.4) 63.13 (160.4) Feedwater inlet; in. (cm) 63.13 (160.4) 63.13 (160.4) Flue diameter, o.d.; in. (cm) 24 (61) 24 (61) Air inlet connection; in. (cm) 25.75 (65.4) 31.9 (81.0) Air inlet connection; in. (cm) 21.25 (54.0) 20.9 (53.0) Main Gas inlet; in. (cm) 24.38 (62) 19.75 (50.2) Gas inlet; in. (cm) 57.63 (146.4) 5.25 (13.3) Gas inlet; in. (cm) 105.88 (269) 97.75 (248.3) Oil inlet; in. (cm) 16.5 (42) N/A Oil return; in. (cm) 19.75 (50.2) N/A Oil inlet; in. (cm) 23.38 (59.4) N/A Oil return; in. (cm) 33.75 (85.7) N/A Feedwater inlet (FPT); in. 3 3 Separator discharge outlet; in. (300# R.F. flng.) 4 4 Separator drain (FPT); in. 1-1/2 1-1/2 Steam Trap discharge outlet (FPT); in. 1-1/4 1-1/2 Coil blowdown drain, w/o SE (FPT); in. 1-1/2 1-1/2 Coil blowdown drain, w/ SE (FPT); in. 1-1/4 1-1/4 Coil gravity drain (FPT); in. 2-1/2 2-1/2 Upper waterwall drain, SE only; in. 1-1/4 1-1/4 Pilot gas inlet (FPT); in. 1/2 1/2 Main gas inlet (FPT); in. 1-1/2 1-1/2 Fuel oil inlet (FPT); in. 1/2 N/A Fuel oil return (FPT); in. 1/2 N/A Atomizing Air Inlet-Oil Units (FPT); in. 1/2 N/A Gravity fill inlet (FPT); in. 3/4 3/4 Sootblow connection-Oil Units (MPT); in. 1-1/2 N/A Safety Valve outlet See Plan Installation Drawing for Relief Generator shipping weight w/o SE; lb (kg) 7,500 (3,402) 7,500 (3,402) Generator shipping weight w/ SE; lb (kg) 8,400 (3,810) 8,400 (3,810) Pump shipping weight; lb (kg) 1,200 (545) 1,200 (545) Sect06_TechSpecs_xx4_L.fm 6-12 E-304 114.63 (291) 137.13 (348) 122 (310) 144.5 (367) 96.38 (244.8) 112.5 (285.8) 26.88 (68.3) 56.63 (143.8) 53 (134.6) 6.88 (17.5) 2.5 (6.4) 6.88 (17.5) 17.88 (45.4) 33.88 (86) 12.38 (31.4) 40.63 (103.2) 4.38 (11) 89.5 (227.3) 103.5 (263) 28.75 (73) 63.13 (160.4) 63.13 (160.4) 24 (61) 25.75 (65.4) 21.25 (54.0) 24.38 (62) 57.63 (146.4) 105.88 (269) 16.5 (42) 19.75 (50.2) 23.38 (59.4) 33.75 (85.7) 3 4 1-1/2 1-1/4 1-1/2 1-1/4 2-1/2 1-1/4 1/2 1-1/2 1/2 1/2 1/2 3/4 1-1/2 Valve connections. 9,200 (4,173) 10,530 (4,776) 1,200 (545) 04/22/2015 Section VI - Technical Specifications Table 6-3: Equipment layout and dimensions for E304FMB–E354FMB modulating Steam Generators with flush-floor frame (refer to Figure 6-2 for layout and item callouts) Model: Layout & Dimensions Connection Sizes & Types Approximate Shipping Weights 04/22/2015 Item C C D D OW OL E F G H1 H2 I J K L M N O O1 P Q R S T1 T2 V W X Y Z AA AB E-304FMB Specification Generator height, w/o SE; in. (cm) Generator height, w/ SE; in. (cm) Coil removal height, w/o SE; in. (cm) Coil removal height, w/ SE; in. (cm) Overall generator width; in. (cm) Overall generator length (gas); in. (cm) Frame mounting, generator; in. (cm) Frame mounting, generator; in. (cm) Frame mounting, generator; in. (cm) Frame mounting, generator; in. (cm) Frame mounting, generator; in. (cm) Frame mounting, pump to generator; in. (cm) Frame mounting, pump; in. (cm) Frame mounting, pump; in. (cm) Frame mounting, pump; in. (cm) Steam outlet; in. (cm) Steam outlet; in. (cm) Steam outlet; in. (cm) Steam outlet, w/ sootblow; in. (cm) Feedwater inlet; in. (cm) Feedwater inlet; in. (cm) Feedwater inlet; in. (cm) Flue diameter, o.d.; in. (cm) Air inlet connection; in. (cm) Air inlet connection; in. (cm) Main Gas inlet; in. (cm) Gas inlet; in. (cm) Gas inlet; in. (cm) Oil inlet; in. (cm) Oil return; in. (cm) Oil inlet; in. (cm) Oil return; in. (cm) Feedwater inlet (FPT); in. Separator discharge outlet; in. (300# R.F. flng.) Separator drain (FPT); in. Steam Trap discharge outlet (FPT); in. Coil blowdown drain, w/o SE (FPT); in. Coil blowdown drain, w/ SE (FPT); in. Coil gravity drain (FPT); in. Upper waterwall drain, SE only; in. Pilot gas inlet (FPT); in. Main gas inlet (FPT); in. Fuel oil inlet (FPT); in. Fuel oil return (FPT); in. Atomizing Air Inlet-Oil Units (FPT); in. Gravity fill inlet (FPT); in. Sootblow connection-Oil Units (MPT); in. Safety Valve outlet Generator shipping weight w/o SE; lb (kg) Generator shipping weight w/ SE; lb (kg) Pump shipping weight; lb (kg) 6-13 E-354 E-354FMB 121.88 (310) 114.63 (291) 121.88 (310) 144.38 (367) 137.13 (348) 144.38 (367) 129 (327.7) 122 (310) 129 (327.7) 152 (386.1) 144.5 (367) 152 (386.1) 105.38 (267.7) 96.38 (244.8) 105.38 (267.7) 158.5 (402.6) 115 (292.1) 158.5 (402.6) 26.88 (68.3) 26.88 (68.3) 26.88 (68.3) 56.63 (143.8) 56.63 (143.8) 56.63 (143.8) 53 (134.6) 53 (134.6) 53 (134.6) 6.88 (17.5) 6.88 (17.5) 6.88 (17.5) 2.5 (6.4) 2.5 (6.4) 2.5 (6.4) 6.88 (17.5) 6.88 (17.5) 6.88 (17.5) 17.88 (45.4) 17.88 (45.4) 17.88 (45.4) 33.88 (86) 33.88 (86) 33.88 (86) 12.38 (31.4) 12.38 (31.4) 12.38 (31.4) 40.63 (103.2) 40.63 (103.2) 40.63 (103.2) 4.38 (11) 4.38 (11) 4.38 (11) 89.5 (227.3) 89.5 (227.3) 89.5 (227.3) 103.5 (263) 103.5 (263) 103.5 (263) 28.75 (73) 28.75 (73) 28.75 (73) 63.13 (160.4) 63.13 (160.4) 63.13 (160.4) 63.13 (160.4) 63.13 (160.4) 63.13 (160.4) 24 (61) 24 (61) 24 (61) 37.83 (96.0) 25.75 (65.4) 37.83 (96.0) 23.84 (60.6) 21.25 (54.0) 23.84 (60.6) 19.75 (50.2) 24.38 (62) 19.75 (50.2) 5.25 (13.3) 57.63 (146.4) 5.25 (13.3) 97.75 (248.3) 105.88 (269) 97.75 (248.3) N/A 16.5 (42) N/A N/A 19.75 (50.2) N/A N/A 23.38 (59.4) N/A N/A 33.75 (85.7) N/A 3 3 3 4 4 4 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/4 1-1/4 1-1/4 2-1/2 2-1/2 2-1/2 1-1/4 1-1/4 1-1/4 1/2 1/2 1/2 1-1/2 1-1/2 1-1/2 N/A 1/2 N/A N/A 1/2 N/A N/A 1/2 N/A 3/4 3/4 3/4 N/A 1-1/2 N/A See Plan Installation Drawing for relief valve connections. 9,200 (4,173) 9,200 (4,173) 9,200 (4,173) 10,530 (4,776) 10,530 (4,776) 10,530 (4,776) 1,200 (545) 1,200 (545) 1,200 (545) Sect06_TechSpecs_xx4_L.fm Steam Generator and Fluid Heater Installation Manual E804 Q1 J1 (3x) C1 I1 L K1 (2x) K1 (2x) R P B1 G1 (2x) G2 E (2x) F (2x) H K J1 (2x) L E654E704 K3 (2x) K2 J2 (2x) I1 K1 G1 (2x) G2 E (2x) F (2x) H Figure 6-3 Equipment layout for E654–E804 modulating steam generators Sect06_TechSpecs_xx4_L.fm 6-14 04/22/2015 Section VI - Technical Specifications Table 6-4: Equipment layout and dimensions for E654–E804 modulating Steam Generators (refer to Figure 6-3 for layout and item callouts) Item OW OL B1 C C1 D E F G1 G2 H I1 Layout J1 J2 K K1 K2 K3 & L M Dimensions N O O1 P Q1 Q2 R S T1 T2 V W X Y Z AA AB AC Connection Sizes & Types Shipping Weights 04/22/2015 Model: E654 Specification Generator width, overall; in. (cm) Generator length, overall (gas); in. (cm) Pump length; in. (cm) Generator height, w/o SE; in. (cm) Generator height, w/ SE; in. (cm) Pump height; in. (cm) Coil removal height, w/o SE; in. (cm) Coil removal height, w/ SE; in. (cm) Frame mounting, generator; in. (cm) Frame mounting, generator; in. (cm) Frame mounting, generator; in. (cm) Frame mounting, generator; in. (cm) Frame mounting, generator; in. (cm) Frame mounting, pump to generator; in. (cm) Frame mounting, pump; in. (cm) Frame mounting, pump; in. (cm) Frame mounting, pump; in. (cm) Frame mounting, pump; in. (cm) Frame mounting, pump; in. (cm) Frame mounting, pump; in. (cm) Frame mounting, pump to generator; in. (cm) Steam outlet; in. (cm) Steam outlet; in. (cm) Steam outlet; in. (cm) Steam outlet, w/ sootblow; in. (cm) Feedwater inlet; in. (cm) Feedwater inlet; in. (cm) Feedwater inlet; in. (cm) Feedwater inlet; in. (cm) Flue diameter, o.d.; in. (cm) Air inlet connection; in. (cm) Air inlet connection; in. (cm) Main Gas inlet; in. (cm) Gas inlet; in. (cm) Gas inlet; in. (cm) Oil inlet; in. (cm) Oil return; in. (cm) Oil inlet; in. (cm) Oil return; in. (cm) Gravity fill; in. (cm) Feedwater inlet (r. f. flange); in. Separator/Standpipe discharge outlet; in. Separator drain (r. f. flange); in. Steam Trap discharge outlet (r. f. flange); in. Coil blowdown drain, w/o SE (r. f. flange); in. Coil blowdown drain, w/ SE (r. f. flange); in. Coil gravity drain (r. f. flange); in. Upper waterwall drain, SE only (r. f. flange); in. Pilot gas inlet (FPT); in. Main gas inlet (MPT); in. Fuel oil inlet (FPT); in. Fuel oil return (FPT); in. Atomizing Air Inlet-Oil Units (FPT); in. Gravity fill inlet (FPT); in. Safety Valve outlet Generator shipping weight w/o SE; lb (kg) Generator shipping weight w/ SE; lb (kg) Pump shipping weight; lb (kg) 151.88 (385.8) 138.75 (352.4) 52.75 (134) 205.13 (521) 215.13 (546.4) 98.9 (251.2) 218.13 (554) 219.63 (558) 42.13 (107) 62.75 (159.4) 62.75 (159.4) 52 (139.1) 5.38 (13.7) 6.13 (15.6) 36 (91.4) 12 (30.5) 43.13 (109.6) 14.78 (37.5) 16.38 (41.6) 12 (30.5) 22.5 (57.2) 39.38 (100) 10.88 (27.6) 118.75 (301.6) 136.38 (346.4) 27.13 (68.9) 123.25 (313.1) 60.75 (154.3) 75.75 (192.4) 35.75 (90.8) n/a n/a 28 (71.1) 69.25 (175.9) 123.75 (314.3) 24.63 (62.6) 27.88 (70.8) 31 (78.7) 22.63 (57.5) 82.63 (209.9) (2x) 4 6 1.5 1.5 1.5 1.5 1 1 .5 2.5 .5 .5 .5 .75 See Plan Installation 24,500 (11,113) 27,800 (12,609) 2,400 (1,089) 6-15 E-704 E804 151.88 (385.8) 132.13 (335.6) 138.75 (352.4) 150.63 (382.6) 52.75 (134) 102.38 (260) 205.13 (521) 197.5 (501.7) 215.13 (546.4) 223.75 (568.3) 98.9 (251.2) 70.88 (180) 218.13 (554) 184.5 (468.6) 219.63 (558) 229.75 (583.7) 42.13 (107) 42 (106.7) 62.75 (159.4) 78.5 (199.4) 62.75 (159.4) 62.75 (159.4) 52 (139.1) 50 (127) 5.38 (13.7) 7 (17.8) 6.13 (15.6) 24.25 (61.6) 36 (91.4) 28.25 (71.6) 12 (30.5) n/a 43.13 (109.6) n/a 14.78 (37.5) 41.38 (105.1) 16.38 (41.6) 41.38 (105.1) 12 (30.5) n/a 22.5 (57.2) 30.13 (76.5) 39.38 (100) 53.25 (135.3) 10.88 (27.6) 7.5 (19.1) 118.75 (301.6) 127.25 (323.2) 136.38 (346.4) 144.88 (368) 27.13 (68.9) 17.5 (44.5) 123.25 (313.1) 13.13 (33.4) 60.75 (154.3) n/a 75.75 (192.4) 50.63 (128.6) 35.75 (90.8) 35.75 (90.8) 37.64 (95.6) n/a 35.7 (90.7) n/a 28 (71.1) 27.88 (70.8) 69.25 (175.9) 75 (190.5) 123.75 (314.3) 142 (360.7) 24.63 (62.6) 20.75 (52.7) 27.88 (70.8) 24 (61) 31 (78.7) 36 (91.4) 22.63 (57.5) 22.88 (58.1) 82.63 (209.9) 87.25 (221.6) (2x) 4 4 6 6 1.5 1.5 1.5 1.5 1.5 2 1.5 2 1 1 1 1 .5 .5 2.5 3 .5 .5 .5 .5 .5 .5 .75 .75 Drawing for safety valve connections. 24,500 (11,113) 22,750 (10,320) 27,800 (12,609) n/a 2,400 (1,089) 3,200 (1,452) Sect06_TechSpecs_xx4_L.fm ANCHOR HOLES (6x) Z Y N OL AB AA M D C W oS B1 X Q1 R OW G1 (2x ) P C1 O1 O2 E (2x) I1 J1 (3x) O K1 (2x) AC K2 (2x) F (2x ) G L (3x) ANCHOR HOLES (6x) V Steam Generator and Fluid Heater Installation Manual Figure 6-4 Equipment layout for E1004–1104 modulating steam generators Sect06_TechSpecs_xx4_L.fm 6-16 04/22/2015 Section VI - Technical Specifications Table 6-5: Equipment layout and dimensions for E1004–E1104 modulating Steam Generators (refer to Figure 6-4 for layout and item callouts) Model: Item OW OL B1 C C1 D E F G G1 H I1 Layout J1 J2 K K1 K2 & L M Dimensions N O O1 O2 P Q1 Q2 R S V W X Y Z AA AB AC Connection Sizes & Types Shipping Weights 04/22/2015 E-1004 Specification Generator width, overall; in. (cm) Generator length, overall (gas); in. (cm) Pump length; in. (cm) Generator height, w/o SE; in. (cm) Generator height, w/ SE; in. (cm) Pump height; in. (cm) Coil removal height, w/o SE; in. (cm) Coil removal height, w/ SE; in. (cm) Frame mounting, generator; in. (cm) Frame mounting, generator; in. (cm) Frame mounting, generator; in. (cm) Frame mounting, generator; in. (cm) Frame mounting, generator; in. (cm) Frame mounting, pump to generator; in. (cm) Frame mounting, pump; in. (cm) Frame mounting, pump; in. (cm) Frame mounting, pump; in. (cm) Frame mounting, pump; in. (cm) Frame mounting, pump; in. (cm) Frame mounting, pump to generator; in. (cm) Steam outlet; in. (cm) Steam outlet; in. (cm) Steam outlet; in. (cm) Steam outlet / sootblow / valve option; in. (cm) Steam outlet-safety relief valves; in. (cm) Feedwater inlet; in. (cm) Feedwater inlet; in. (cm) Feedwater inlet; in. (cm) Feedwater inlet; in. (cm) Flue diameter, o.d.; in. (cm) Main Gas inlet; in. (cm) Gas inlet; in. (cm) Gas inlet; in. (cm) Oil inlet; in. (cm) Oil return; in. (cm) Oil inlet; in. (cm) Oil return; in. (cm) Gravity fill; in. (cm) Feedwater inlet (FPT); in. Separator/Standpipe discharge outlet; in. Separator drain (FPT); in. Steam Trap discharge outlet (FPT); in. Coil blowdown drain, w/o SE (FPT); in. Coil blowdown drain, w/ SE (FPT); in. Coil gravity drain (FPT); in. Upper waterwall drain, SE only; in. Pilot gas inlet (FPT); in. Main gas inlet (MPT); in. Fuel oil inlet (FPT); in. Fuel oil return (FPT); in. Atomizing Air Inlet-Oil Units (FPT); in. Gravity fill inlet (FPT); in. Safety Valve outlet Generator shipping weight w/o SE; lb (kg) Generator shipping weight w/ SE; lb (kg) Pump shipping weight; lb (kg) 6-17 170.9 (434.1) 254.4 (646.2) 92.0 (233.7) 220.7 (560.6) 233.7 (593.4) 69.81 (177.3) 226.0 (574.0) 239.0 (610.0) 55.3 (140.3) 87.5 (222.25) 74.1 (188.3) 89.1 (226.4) n/a 32.8 (83.3) 33.0 (83.8) n/a n/a 38.0 (96.5) 38.0 (96.5) 23.0 (58.4) 57.8 (146.8) 12.9 (32.8) 123.8 (314.4) 178.4 (453.1) 144.5 (367.0) 16.5 (41.9) 27.8 (70.6) n/a 40.2 (102.0) 43.8 (111.3) 21.3 (54.1) 113.2 (287.5) 157.5 (400.0) 37.7 (95.8) 6.8 (17.3) 34.9 (88.6) 30.8 (78.2) 99.0 (251.5) 4 8 2 2 2 3 4 3 0.5 4 1 1 0.5 1 E-1104 170.9 (434.1) 237.8 (604) 92.0 (233.7) 220.7 (560.6) 233.7 (593.4) 69.81 (177.3) 226.0 (574.0) 239.0 (610.0) 55.3 (140.3) 87.5 (222.25) 74.1 (188.3) 89.1 (226.4) n/a 32.8 (83.3) 33.0 (83.8) n/a n/a 38.0 (96.5) 38.0 (96.5) 23.0 (58.4) 57.8 (146.8) 12.9 (32.8) 123.8 (314.4) 178.4 (453.1) 144.5 (367.0) 16.5 (41.9) 27.8 (70.6) n/a 40.2 (102.0) 43.8 (111.3) 21.3 (54.1) 113.2 (287.5) 157.5 (400.0) 37.7 (95.8) 6.8 (17.3) 34.9 (88.6) 30.8 (78.2) 99.0 (251.5) 4 8 2 2 2 3 4 3 0.5 4 1 1 0.5 1 47,500 (21,545) 47,500 (21,545) 50,000 (22,680) 50,000 (22,680) 3,200 (1,452) 3,200 (1,452) Sect06_TechSpecs_xx4_L.fm Steam Generator and Fluid Heater Installation Manual 6.7.2 Condensate Receiver Tanks BHP 250 350 750 900 1600 Operating Volume 180 GAL. 250 GAL. 425 GAL. 551 GAL. 757 GAL. Full Volume 266 GAL. 372 GAL. 667 GAL. 865 GAL. 1,135 GAL. Part No. UH31909 UH32701 UH32791 UH32377 UH33814 A 31.33 31.33 41.12 41.12 48.00 B 28.34 28.34 36.00 36.00 44.00 C 60.83 84.69 93.12 120.62 145.12 D 36.36 36.36 46.36 46.50 63.00 E 40.00 40.00 60.00 84.00 101.00 F 6.00 6.00 6.00 6.00 6.00 G 5.09 5.16 3.29 6.48 3.80 H 37.92 37.83 51.98 53.48 68.52 SF1 - Condensate Return SF2 - Low Pressure Condensate Return SF3 - Optional HP condensate return, w/ sparger tube for 50% or higher return SA - Feedwater Outlet SB - Vent SC - Drain SE - Steam Heat SF - Trap Return SH - Make Up Return Note: 1) Refer to applicable P&ID drawing for hotwell trim connections. 2) Sparger tube for SF1 optional. Recommended for condensate returns over 50%. R019740 Figure 6-5 Horizontal hotwell dimensions and specifications Sect06_TechSpecs_xx4_L.fm 6-18 04/22/2015 Section VI - Technical Specifications Blowdown Tanks CLAYTON PART NO.: 0028689 BHP: 16–300 6.7.3 Figure 6-6 Blowdown tank dimensions and specifications for 16–300 bhp (illustration rotated 90o counterclockwise) 04/22/2015 6-19 Sect06_TechSpecs_xx4_L.fm CLAYTON PART NO.: 0028690 BHP: 150–350 Steam Generator and Fluid Heater Installation Manual Figure 6-7 Blowdown tank dimensions and specifications for 150–350 bhp (illustration rotated 90o counterclockwise) Sect06_TechSpecs_xx4_L.fm 6-20 04/22/2015 CLAYTON PART NO.: 0050112 BHP: 400–2,000 Section VI - Technical Specifications Figure 6-8 Blowdown tank dimensions and specifications for 605–2,000 bhp (illustration rotated 90o counterclockwise) 04/22/2015 6-21 Sect06_TechSpecs_xx4_L.fm Steam Generator and Fluid Heater Installation Manual (This page intentionally left blank.) Sect06_TechSpecs_xx4_L.fm 6-22 04/22/2015 SECTION VII - OPTIONAL EQUIPMENT 7.1 BOOSTER PUMP(S) Booster pumps are required on an open system when the required NPSH to the feedwater pump cannot be achieved from an elevated hotwell. In a deaerator (D/A) system, booster pumps are required for most installations. Due to the low NPSH characteristics of these pumps, they are less sensitive to feedwater delivery problems caused by fluctuating pressure in the D/A than the Clayton feedwater pump(s). Booster pumps must be sized to provide 150 percent of the total system water flow at 150 percent of the total system head pressure. Total system head pressure includes the Clayton feedwater pump NPSHR, plus calculated pipe losses, and plus acceleration head loss. Most systems use two pumps. One of the two pumps is a standby pump, or the usage of the two pumps are alternated to balance operating hours. Only booster pumps with mechanical seals rated at a minimum of 250o F (121o C) should be used. The booster pumps cannot be rated at a discharge pressure that is lower than the system operating pressure NOTE Each booster pump must have a 1/4 inch (6 mm) recirculation line, with a check-valve, piped from the discharge side of the pump back to the condensate receiver. This prevents overheating during “dead head” conditions. Clayton recommends using this return line to facilitate chemical injection at a common manifold on the condensate receiver. 7.2 BLOWDOWN SYSTEM 7.2.1 Blowdown Tank The Occupational Safety and Health Administration (OSHA) requires that high temperature discharges be cooled to a temperature below 140o F (60o C) prior to entering a drainage system. A blowdown tank is performs this function. All blowdown and high temperature drain lines are to be piped to the blowdown tank. A capillary tube-type temperature sensor, mounted in the blowdown tank discharge line, actuates a temperature control valve, also mounted in the discharge line, to inject cooling water into the hot fluid. The temperature control valve can be adjusted to achieve the desired discharge fluid temperature. The blowdown tank vent should be a straight run of full size iron or steel pipe. 04/22/2015 7-1 Sect07_e_022010.fm Steam Generator & Fluid Heater Installation Manual 7.2.2 Automatic TDS Controller Total dissolved solids can be controlled automatically. This is accomplished by installing a TDS (conductivity) sensing probe in the feedwater line, this is connected to the Clayton Boiler Master controller that, in turn, controls a dump valve installed in the trap discharge line. The discharge from the dump valve is then piped to the blowdown tank. Refer to Drawing R-16099. Feedwater testing is still required per the Clayton Feedwater Manual. 7.2.3 Continuous Blowdown Valve The continuous blowdown valve, if used, is installed in the trap discharge line. It consists of a needle valve that is throttled for the proper flow rate to keep TDS within parameters. Refer to Drawing R-16099. 7.3 VALVE OPTION KIT The valve option kit consists of a separator drain valve, coil gravity drain valve, coil blowdown valve, and separator-trap discharge valve. The valve kit also includes the required hardware, such as nuts, bolts, gaskets, and pipe nipples, for the valve installation. With the exception of generator skids and the steam trap discharge valve, all valves are shipped loose for customer installation. If the valve option kit is not supplied by Clayton, it is the customers responsibility to provide these valves. All these valves are required for proper installation and operation. 7.4 SOOT BLOWER ASSEMBLY For generators that burn oil, a provision for steam soot blowing is required. Clayton Industries can provide an optional steam pipe spool piece with all piping and valves required for the proper removal of accumulated soot. If this item is not purchased the customer must supply a valved line from the steam header to the soot blow inlet for this purpose. 7.5 PRESSURE REGULATING VALVES (BPR/PRV) 7.5.1 Back Pressure Regulators Back Pressure Regulators (BPR), in the separator discharge piping, are required when the system requirements exceed the capacity of the steam generator/fluid heater, where there are cycling loads, such as those created from a fast-acting motorized valve, or on steam generators/ fluid heaters that are started remotely or automatically, such as master lead-lag or auxiliary pressure control systems. BPRs are recommended on all Clayton installations. The BPRs assure that sufficient pressure is maintained in the steam generator/fluid heater to protect the heating coil from a possible overheat condition. Pilot operated BPRs are meant to be mounted at the steam header top elevation, immediately next to the steam stop valves above Clayton’s (remote) separator. They are not meant to be floor mounted. Pilot lines must be trapped to prevent liquid lockout. Customers who desire mounting BPRs at floor level must use pilotless electro-pneumatic BPRs. Sect07_e_022010.fm 7-2 04/22/2015 Section VII 7.5.2 Pressure Regulating Valves Pressure Regulating Valves (PRV) control the pressure in the feedwater supply vessel, either D/A or Semi-closed Receiver (SCR) Systems. These valves ensure positive pressure is maintained on these vessels. The PRV receives steam from the main header and injects steam into the tank when a drop in pressure is detected. A check-valve must be installed in this line to protect the system in the event of flooding the tank. 04/22/2015 7-3 Sect07_e_022010.fm Steam Generator & Fluid Heater Installation Manual (This page intentionally left blank.) Sect07_e_022010.fm 7-4 04/22/2015 SUPPLEMENT I - SCR 1.1 SEMI-CLOSED RECEIVER SYSTEMS (SCR) 1.1.1 Requirements A Semi-closed Receiver system is used when condensate can be returned at relatively high pressure and temperature. The pressure of the receiver tank is determined by the condensate return system. When the system is warm and operating at its normal “balanced pressure” the Back Pressure Regulator and Pressure Regulating Valve may be set. SCR systems typically operate between 50–125 psi and must be at least 50 psi below the anticipated steam pressure. Because of these higher operating pressures/temperature (feedwater will be between 300o–350o F) feedwater chemical treatment is reduced but not eliminated. Because of the elevated feedwater temperature, cooling water is circulated over the pump heads in the feedwater pump. This helps keep the pump diaphragms cool thereby extending the life. The pump head cooling water does not have to be softened water unless it is returned to the hotwell. Installation of cooling water lines to the pump head connections is the responsibility of the installing contractor. 1.1.2 Components of an SCR System refer to Drawing R-16596 The Semi-closed Receiver must be sized to a total capacity of 1.5 gallons per boiler horsepower. Multiple generators may be operated from one receiver if the installation is operating at a common pressure. The receiver tank must comply with the ASME Section VIII Code specifications for unfired Pressure Vessels. There must also be a large valved drain line in the bottom of the receiver to permit periodic draining and flushing of the tank. NOTE Receiver must be installed to provide sufficient NPSH to the feedwater pump(s). See Section 2.11. 1.1.3 Water Level Gauge Glass A sight glass must be mounted on the receiver for visual verification of the operating water level. This glass must be rated for the operating pressure/temperature and be at least one foot long. 1.1.4 Steam Trap An overflow steam trap is required to control the maximum water level, when above normal amounts of condensate are being returned. The trap inlet must have a priming drip leg at least eighteen inches long. The trap discharge must be piped to the make-up tank. 04/22/2015 SI-1 Supplmt01_SCR_b.fm Steam Generator & Fluid Heater Installation Manual 1.1.5 Vent The receiver must have a vent to discharge non-condensable gases from the feedwater. The Clayton vent most often provided is a 3/4 inch orifice union with a 1/8 inch orifice. This will continuously vent a small amount of steam with the gases. 1.1.6 Level Control A liquid level controller is mounted on the receiver to control the make-up water pump. This control starts and stops the make-up pump as required. The differential between the high and low levels is a narrow band (2 to 3 inches). The water level should be maintained approximately one quarter from the top of the tank, and at the proper height for the required NPSH of the generator feedwater pump. 1.1.7 Steam Relief Valve The SCR must have a steam safety relief valve with a setting not greater than the design pressure of the tank. This valve must comply with all safety codes and must be capable of relieving at least 25 percent of the connected Generator Steaming capacity at the SCR operating pressure. The discharge from this valve must be piped to atmosphere and in a direction that will not cause harm to equipment or personnel. 1.1.8 Sparger Tube The high pressure condensate returns must be injected into the SCR through a sparger tube. The sparger tube inlet must be 8–12 inches below the lowest water level so the heat will be transferred from the condensate to the liquid in the SCR with the least possible noise and vibration. The trap returns from the Clayton Separator should also be piped into the sparger tube. 1.1.9 Back Pressure Regulator A Back Pressure Regulator (BPR) must be installed on the receiver to help control the tank pressure during large load swings, or in the event of system traps malfunction. The BPR should be set at 3–5 psi above the normal operating pressure. 1.1.10 Pressure Reducing Valve A Pressure Regulating Valve (PRV) must be installed on the SCR to maintain a preset pressure. The PRV senses the SCR pressure and injects steam (above the water level) from the header in the event of a reduction in the tank pressure. The PRV should be set at 1–2 psi below the normal operating pressure. The PRV design flow must be equal to 25 percent of the maximum steam production rate. If low pressure steam is to be drawn from the receiver for other uses, this capacity must be considered when sizing the PRV. A check-valve must be installed between the PRV and the receiver to prevent backflow in the event of a flooded condition in the receiver. NOTE The PRV and BPR are not options. They must be installed to ensure the effective and efficient operation of the Clayton Semi-closed Receiver System. Supplmt01_SCR_b.fm SI-2 04/22/2015 Supplement I 1.1.11 Make-up Tank A make-up tank is required to collect low pressure condensate and fresh softened make-up water. Steam is introduced to the make-up tank through a temperature control valve. The make-up tank temperature should be maintained between 190o–200o F. The make-up tank must be sized for the total boiler horsepower rating of the system. The make-up tank must also have sufficient elevation to provide the required NPSH of the make-up. 1.1.12 SCR Transfer Pump An SCR transfer pump is required to transfer water from the make-up tank to the SCR (regenerative turbine type preferred). This pump must have a capacity that is at least equal to the total boiler feedwater pump capacity. The make-up pump must have a discharge head not less than 25 percent higher than the maximum receiver operating pressure. The discharge from this pump must enter the SCR below the minimum water level. NOTE A check-valve must be installed in the make up pump discharge line as close to the SCR as possible. This will prevent exposing the pump seal to excessive fluid temperatures. 1.1.13 Chemical Treatment Feedwater Chemical Treatment is injected into the SCR below the water level. Feedwater treatment Chemicals are also be injected into the make-up tank to help protect the make up against corrosion. Both of these chemical injection lines must have a check-valve installed to prevent back feeding into the chemical pumps. Chemical pump output pressure must be greater than SCR pressure. 1.1.14 Hook-up The feedwater line between the SCR and the Generator feedwater water pump must have an inside diameter of 1.5 times that of the feedwater pump inlet connection. Elbows and restrictions must be kept at a minimum, and a flex section (2 feet minimum) must be installed on the feedwater pump inlet. Provision for a thermometer must be as close to the feedwater pump inlet as possible. 1.1.15 System Steam Traps The steam traps in the system must be rated for the system pressure, and sized for the difference between the steam system and the receiver. This usually requires the traps be one size larger than on an open system. The steam traps in the system must be properly maintained for the system to function normally. If there are traps “blowing by” the SCR will be pressurized above the Back Pressure Regulator set point and steam will be needlessly vented to atmosphere. 04/22/2015 SI-3 Supplmt01_SCR_b.fm Steam Generator & Fluid Heater Installation Manual 1.1.16 A General Statement Because of the uniqueness of an SCR system, the requirements put forth here must be closely followed to ensure trouble free operation. If properly installed and maintained the Clayton Semi-closed Receiver System will operate with a high degree of reliability and economic benefits. Supplmt01_SCR_b.fm SI-4 04/22/2015 SUPPLEMENT II - HEAVY OIL 2.1 HEAVY FUEL OIL (MODELS E-154 TO E-504) 2.1.1 General Statement All Clayton heavy oil steam generators/fluid heaters require starting and stopping on light oil; therefore, an ample supply of light oil must always be available during startup and shutdown of the machine. In addition, the light oil supply is needed for flushing all heavy oil from the machine’s fuel system and from the heavy oil heater unit during shutdown procedure. Special handling, storage, maintenance, and proper operation are required when burning heavy fuel oil (other than #2). This supplement is intended as a general guide to aid the installer in the proper preparation of a site that will be using heavy oil. Careful consideration must be given to local codes and requirements when dealing with heavy fuel oil. The installer should observe the standards as established by the National Fire Protection Agency (NFPA), National Electric Code (NEC) and the Environmental Protection Agency (EPA). Heavy fuel oil is typically a blend of distillates and residuals or even crudes. To keep the oils from separating in the storage it must be heated to 50o F above the pour point. If the blended oils are permitted to cool they can separate and form a sludge on the tank bottom. (Refer to chart R-8571 for viscosity and temperatures.) 2.1.2 Storage Tanks In order to maintain the temperature in the fuel oil storage tank, the tank has to be heated to a minimum of 100o–130o F. Tank heaters may operate on hot water, steam, or electricity. If steam or hot water is available for a cold start, they are the more economical method of heating the tank. Normally, the heating coils are placed 6 inches above the lowest level in the tank. It is not necessary to have uniform heating throughout the tank if the oil return is at the opposite end from the pump suction since this provides a positive circulation throughout the tank. Additional heating must be provided with a heater bell at the pump suction point. If steam from the generator system is to be used for tank heating it must be piped to waste. NOTE All fuel oil storage tanks must be constructed in accordance with local and EPA codes. If an above ground tank is used, it must be insulated with a waterproof insulation. 2.1.3 Transfer Pump Fuel oil is pumped from the storage tank to the Clayton fuel pump through an oil transfer pump, owner supplied. This pump should be a positive displacement pump (gear type or similar) and have a capacity of twice the total burner volume. Future steam generation capacity should be considered when sizing this pump. The pump should have the ability to turn over the tanks volume in a week. A suitable fuel strainer must be installed on the suction side of the transfer pump. This strainer will remove foreign 04/22/2015 SII-5 Supplmt02_HeavyOil_c.fm STEAM GENERATOR & FLUID HEATER INSTALLATION MANUAL particles that could damage the transfer and generator fuel pumps. The strainer should have a mesh not larger than 0.015 inch. The inlet pressure to the Clayton pump must not exceed 25 psi. A higher inlet pressure will damage the pump seals. NOTE The transfer pump must be equipped with a foot valve to avoid draining fuel back into the storage tank. Both the transfer and Clayton fuel pumps should run continuously, circulating oil under pressure through the heaters to the burner. Excess oil flows through the Fuel Pressure Regulator to the inlet of the fuel pump. In a burner off cycle, the Oil Recirculating Valve opens and bypasses the fuel to the inlet of the fuel pump. This oil is at a higher temperature than the oil in the transfer loop. With this system, all the high temperature oil is confined to the burner loop. Oil heated in the transfer loop should be limited to 20o F below flash point (this temperature depends on oil viscosity). 2.1.4 Supply and Return Lines Install fuel supply and return lines to the fuel pump from the storage tank, using appropriately sized piping for the required flow. The fuel supply system will depend on the burner design, storage tank, grade of oil, the number of generators, and local codes. NOTE Heavy oil supply and return lines must be heat traced (steam or electric) and insulated. Do not use galvanized pipes. 2.1.5 Oil Preheating Equipment (See Heavy Oil System Flow Diagram) The Clayton heavy oil-fired unit uses an air atomizing burner. For proper combustion the oil viscosity must be a minimum of 55 Saybolt Seconds Universal (SSU). For oil that has a higher viscosity, controlled heating must be applied. The heated fuel temperature requirement varies with the initial viscosity of the oil. (see chart R-8571). A steam heater is provided to accomplish the required rise in temperature. 2.1.6 Electric Immersion Heater Option An Electric Immersion Heater option can be provided with the generator. It is controlled by a Magnetic Controller Switch which is controlled by the Oil Heater Thermostat Switch. This switch is set to a slightly lower cut out point (10o–15o F) than the steam heater operating temperature. This permits the steam heater to do most of the heating. The electric heater is used primarily during start-up when sufficient steam is not available. 2.1.7 Steam Coil Heater When sufficient steam becomes available the steam heater raises the fuel temperature to the proper value. A Temperature Control Valve is used to respond to the temperature of the incoming oil. This valve is set to maintain the fuel oil at the predetermined value (see chart R-8571). Steam that condenses inside the coil is discharged through a steam trap and must be piped to waste to avoid contamination Supplmt02_HeavyOil_c.fm SII-6 04/22/2015 Supplement II NOTE All heavy oil fired units must be started and stopped using light Fuel Oil, #2 diesel. 2.1.8 Exhaust Stack The heavy oil-fired, steam generator exhaust stack should be free standing, with a side inlet and an ash collector. The first stack section attached to the machine must be removable. It should also have an access door for water washing and a port for a thermometer. Any stack section that is inside the building should be insulated to reduce radiant heat loss and noise from vibration. The stack should be constructed of stainless steel for longevity. A vertical stack height over thirty feet may require a barometric damper. 04/22/2015 SII-7 Supplmt02_HeavyOil_c.fm STEAM GENERATOR & FLUID HEATER INSTALLATION MANUAL HEAVY OIL HEATER SKID Figure 2-1 Flow Diagram - Heavy Oil System Supplmt02_HeavyOil_c.fm SII-8 04/22/2015 2.2 FUELS The conversion chart below should always be used in conjunction with enclosed Temperature-Viscosity Charts and is not intended to be used as a direct viscosity conversion. Use the chart below only when desired scale is not on Temperature-Viscosity Chart. (Measured at temperatures are for reference only). Alignment Chart for comparing viscosity scales - Use a straightedge to read horizontal scales–far left and far right scales are identical. 10-2004 HOI-9 R-8571 Rev. G 2.3 CLAYTON STEAM GENERATORS EQUIPPED WITH HEAVY OIL FUEL SYSTEM Heavy Oil Fuel Specifications Clayton Burners require Heater adjustment to suit a specified viscosity. All fuel oil deliveries must have a uniform viscosity. Limit viscosity variation to plus 10% to minus 50% for Air Atomizing Burners. The following specification covers the range of Fuel Grade Nos. 4, 5 and light No. 6 fuel oil in accordance with Commercial Standard CS-12-48 issued by the U.S. Department of Commerce and ASTM Specification D-39664T. Local legal limits may supersede these regulations. Description of Supply Oil Required Preferred Limit Gravity, Degrees API at 15 oC (60 oF) ................................................................ 14-26 10 min. o o Gravity, Specific, at 15 C (60 F) ................................................................. 0.90-0.97 o Flash-Point, Pensky-Martens, ( F) ................................................................... 150-230 o o Viscosity, Saybolt Seconds Furol at 122 F (50 C) (SSF) ..............................45 max. Sulfur, percent, Subject to Local Regulations .................................................0.5 max. Sediment and Water, percent by volume .........................................................0.5 max. Carbon Residue, (on 10% residuum) percent ........................................................ 5-10 Ash, percent by weight ..................................................................................0.05 max. Vanadium, parts per million .............................................................................50 max. (Approximate) Btu per gallon k cal/l High Heat Value 150,000 9,960 1 max. 150 min. 175 max. 2.0 max. 1.0 max. 15 max. 0.10 max. 100 max. Low Heat Value 142,000 9,370 Light Fuel Oil Specifications Fuel oil conforming to U.S. Commercial Standard No. 2 or Pacific Standard No. 200 furnace oil or diesel fuel. Description of Supply Oil Required Preferred Limit Gravity, Degrees API at 60 oF (15 oC ................................................................. 30-38 26 min. o o Gravity, Specific at 60 F (15 C) .................................................................. 0.84-0.87 o Flash Point. Pensky-Martens, F ...................................................................... 160-180 o Viscosity, Saybolt Seconds Universal at 100 F (SSU) ....................................... 35-45 Kinematic Viscosity at 68 oF (20 oC) 0.80-0.90 130 min.-230 max. 45 max. (Centistokes) .................................... 4-9.5 max. 9.5 max. Pour Point, ......................................................................................................0 max. Sediment and Water, Percent by volume ...............................................................none Sulfur, Percent .................................................................................................0.5 max. Carbon Residue (on 10% residuum) Percent .................................................0.02 max. 15 max. 0.10 max. 0.8 max. 0.25 max. oF R-8571 Rev. G HOI-10 10-2004 ASTM Distillation Range Initial Boiling Point, oF .................................................................................... 350-375 o Initial Boiling Point, C ................................................................................ 177-190.5 400 max. 204 max. o 675 max. o 357 max. 90% Recovery, F ............................................................................................ 600-625 90% Recovery, C ............................................................................................ 316-329 End Point, oF .................................................................................................... 675-725 735 max. End Point, oC ................................................................................................... 357-385 390.5 Max. (Approximate) Btu per gallon k cal/l 10-2004 HOI-11 High Heat Value 142,600 9,509 Low Heat Value 135,000 9,006 R-8571 Rev. G 10-2004 HOI-12 R-8571 Rev. G SUPPLEMENT III - FLUID HEATER 3.1 FLUID HEATERS The Clayton Fluid Heater is provided with an off frame mounted steam separator. This type of unit carries a “DZ” model designation. A stand pipe with ASME safety valve remains on the main frame of the Fluid Heater. This type of equipment layout requires remote mounting of the fluid separator with interconnecting piping between the main shut off valve, mounted on the stand pipe, and the inlet of the separator. The piping between the stand pipe mounted main steam shut off valve, and the inlet to the Fluid Heater should be run full size with a minimum of elbows. The remote mounted separator is available without legs, for mounting in the steam header, or with legs/skirt for floor mounting close to the Fluid Heater. 01-2004 SIII-13 R-16600 Rev. D STEAM GENERATOR & FLUID HEATER INSTALLATION MANUAL (This page intentionally left blank.) R-16600 Rev. D SIII-14 01-2004 Appendix A - Steam Generator Lifting Instructions Appendix A Appendix A Steam Generator Lifting Instructions 04/22/2015 A-1 R-16600 Rev. F STEAM GENERATOR & FLUID HEATER INSTALLATION MANUAL Typical rigging for modulating Steam Generators (illustration rotated 90o counterclockwise) R-16600 Rev. F A-2 04/22/2015 Appendix A *Safety cable must be used at ALL TIMES. DO NOT use safety cable for lifting. 14 ft. LIFTING CABLE (4X) SAFETY CABLE (NOTE 1) NOTE: 1. Minimum height for E704 and E1004 is 25 feet. 2. Maximum lifting weight is 17,130 lb. for E704 and 29,000 lb. for E1004. 3. Use forklift only for water pump skid. DO NOT use plumbing for lifting. Typical rigging for E704 and E1004 Steam Generators 04/22/2015 A-3 R-16600 Rev. F STEAM GENERATOR & FLUID HEATER INSTALLATION MANUAL NOTES R-16600 Rev. F A-4 04/22/2015 Appendix B - Saturated Steam P-T Table Appendix B Appendix B Saturated Steam Pressure-Temperature Table GAUGE GAUGE GAUGE GAUGE GAUGE GAUGE PRESSURE PRESSURE PRESSURE PRESSURE PRESSURE PRESSURE PSIG TEMP F kPa TEMP C PSIG TEMP F kPa TEMP C PSIG TEMP F kPa TEMP C 60 308 413.6 153 270 413 1,861.5 211 600 489 4,136.8 254 70 316 482.6 158 280 416 1,930.5 213 650 497 4,481.6 259 80 324 551.5 162 290 419 1,999.4 215 725 509 4,998.7 265 90 331 620.5 166 300 422 2,068.4 217 750 513 5,171.1 267 100 338 689.4 170 310 425 2,137.3 218 775 517 5,343.4 269 110 344 758.4 173 320 428 2,206.3 220 800 520 5,515.8 271 120 350 827.3 177 330 431 2,275.2 222 825 524 5,688.2 273 130 356 896.3 180 340 433 2,344.2 223 850 527 5,860.5 275 140 361 965.2 183 350 436 2,413.2 224 875 531 6,032.9 277 150 366 1,034.2 186 360 438 2,482.1 226 900 534 6,205.3 279 160 370 1,103.2 188 370 441 2,551.1 227 925 537 6,377.7 281 170 375 1,172.1 191 380 443 2,620.0 229 950 540 6,550.0 282 180 380 1,241.0 193 390 445 2,689.0 230 975 543 6,722.4 284 190 384 1,310.0 196 400 448 2,757.9 231 1000 546 6,894.8 286 200 388 1,378.9 198 410 450 2,826.9 233 1050 552 7,239.5 289 210 392 1,447.9 200 420 453 2,895.7 234 1100 558 7,584.2 292 220 396 1,516.8 202 440 457 3,033.6 236 1150 564 7,929.0 295 230 399 1,585.7 204 460 462 3,171.5 239 1200 569 8,273.7 298 240 403 1,654.7 206 480 466 3,309.4 241 1250 574 8,618.4 301 250 406 1,723.6 208 500 470 3,447.3 243 1300 579 8,963.2 304 260 409 1,792.6 210 550 480 3,792.1 249 1350 584 9,307.9 307 08/13/2013 B-5 R-16600 Rev. T Steam Generator & Fluid Heater Installation Manual (This page intentionally left blank.) R-16600 Rev. T B-6 08/13/2013 Appendix C - Piping and Instrumentation Diagrams Appendix C Appendix C Piping and Instrumentation Diagrams (P & I D) Contents Drawing No. Drawing Title Page R016099e (S)EOG-154/504 Open System, Fuel-Electrical, Standard Machines . . . . . . . . . . . . . . . 9 R016099e (S)EOG-154/504 Open System, Fuel-Electrical, LNOx machines . . . . . . . . . . . . . . . . . 10 R016099e (S)EOG-154/504 Open System, Water-Steam . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 R016595d (S)EOG-154/504, Deaerator, Fuel-Electrical, Standard Machines . . . . . . . . . . . . . . . . . 12 R016595d (S)EOG-154/504, Deaerator, Fuel-Electrical, LNOx Machines . . . . . . . . . . . . . . . . . . . 13 R016595d (S)EOG-154/504, Deaerator, Water-Steam . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 R016596d (S)EOG-154/504, SCR, Fuel-Electrical, Standard Machines . . . . . . . . . . . . . . . . . . . . . 15 R016596d (S)EOG-154/504, SCR, Fuel-Electrical, LNOx Machines . . . . . . . . . . . . . . . . . . . . . . . 16 R016596d (S)EOG-154/504, SCR, Water-Steam . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 R016597d (S)EOG-154/504, Condensate Receiver, Fuel-Electrical, Fluid Heater . . . . . . . . . . . . . 18 R016597d (S)EOG-154/504, Condensate Receiver, Fuel-Electrical, Fluid Heater, LNOx . . . . . . . 19 R016597d (S)EOG-154/504 Open System, Water-Steam, Fluid Heater . . . . . . . . . . . . . . . . . . . . . 20 P&ID_a.fm C-8 04/22/2015 04/22/2015 C-9 P&ID_a.fm P&ID_a.fm C-10 04/22/2015 04/22/2015 C-11 P&ID_a.fm P&ID_a.fm C-12 04/22/2015 04/22/2015 C-13 P&ID_a.fm P&ID_a.fm C-14 04/22/2015 04/22/2015 C-15 P&ID_a.fm P&ID_a.fm C-16 04/22/2015 04/22/2015 C-17 P&ID_a.fm P&ID_a.fm C-18 04/22/2015 04/22/2015 C-19 P&ID_a.fm P&ID_a.fm C-20 04/22/2015 Appendix D - Installing SE Option Appendix D Appendix D Installing SE (Super Economizer) Option 04/22/2015 Appndx_SE Option_xx4_c.fm STEAM GENERATOR & FLUID HEATER INSTALLATION MANUAL (This page intentionally left blank.) Appndx_SE Option_xx4_c.fm D-22 04/22/2015 Appendix D INTRODUCTION A Clayton SE (Super Economizer) Coil provides added efficiency to your existing Clayton steam generator/fluid heater. The SE coil allows feedwater supply to be preheated prior to entering the main heating section. This preheated fluid helps to reduce the energy consumption of the machine without compromising its output capacity. An SE coil is offered as a kit. This kit includes the coil assembly, outer shell extensions, band clamps, piping, and necessary hardware. IMPORTANT Before ordering an SE Kit, verify there is ample overhead clearance above the machine. An SE section adds twenty-four to forty-eight inches of height to the machine. Additional clearance must also be available for lifting SE coil onto the main coil. See Section 6.7 for height requirements. WARNING An SE coil assembly weighs several hundred pounds. Make sure all safety measures are observed throughout the SE Kit installation process. Make sure the lifting apparatus that will be used to hoist the SE coil assembly is designed for lifting such weights. NOTE It is always recommended that these procedures be reviewed completely before beginning the SE Kit installation. INSTALLATION Execute a dry shutdown of the machine. See Section IV in the Steam Generator/Fluid Heater Instruction Manual for procedure. Allow the machine to cool. WARNING Secure the machine to prevent accidental start up during SE Kit installation. Remove Heater Covers a. Disconnect and remove the flue exhaust duct from the heater cover. b. Disconnect and remove the existing feedwater supply and discharge piping from the machine. c. Remove the outer heater cover clamp bands and outer heater cover (See Figure 1.) 04/22/2015 D-23 Appndx_SE Option_xx4_c.fm STEAM GENERATOR & FLUID HEATER INSTALLATION MANUAL Figure 1 SE Coil Kit installation diagram (typical) d. If applicable, remove the outer shell extension clamp bands and outer shell extension. e. Remove the inner heater cover clamp bands and inner heater cover. Remove Outer Shells and Top Coil (E704 Steam Generator/Fluid Heater Only) a. Remove the patch-plates around the feedwater supply and the feedwater discharge openings. b. Remove the top outer shell clamp bands. c. Remove the assembly screws for the outer shells and remove the outer shells. Appndx_SE Option_xx4_c.fm D-24 04/22/2015 Appendix D d. Secure the top coil assembly by attaching the lifting apparatus to the lifting hook installed on the top coil assembly. e. Remove the coil clamp bands that secures the top coil assembly to the lower coil assembly. f. Carefully, lift and remove the top coil assembly off the lower coils. Install SE Coil Assembly (See Figure 1.) a. Prepare the main heating section flange ring surface with a layer of G. S. Teflon Thread Sealing Compound. This will aid in adjusting the SE coil assembly into alignment with the main heating section. b. Lift the SE coil assembly up onto the main heating section. NOTE If desired, the inner heater cover may be installed on the SE coil assembly prior to lifting it onto the main heating section. c. Align the SE coil assembly’s bottom flange ring with the main coil section flange ring. d. Rotate the SE coil assembly, as needed, to align the feedwater inlet(s), as shown in Figure 2 and 3. e. Install the inner clamp bands around the main heating section flange ring and the SE coil assembly’s bottom flange ring. Secure the clamp bands with their attaching hardware. f. Place and align the inner heater cover on SE coil assembly. g. Install the inner heater cover clamp bands around the heater cover and the SE coil assembly’s top flange ring. Secure the clamp bands with their attaching hardware. Install Outer Shells a. Two-piece Outer Shells- Lift the rear outer shell piece (the shell piece with the cut-outs) up around the rear-side of the SE coil assembly and the feedwater inlet/discharge, allowing it to rest on the main outer shell below. Using a set of self-locking clamps, Vise-Grip® pliers for example, clamp the SE outer shell to the main outer shell. Three-piece Outer Shells- Pre-assemble the front outer shell piece and the left outer shell piece while on the ground. The left outer shell piece consist of two cut-outs in the lower half. Screw the two shell ends opposite the cut-outs together. Lift these assembled outer shells up around the front and left side of 04/22/2015 D-25 Appndx_SE Option_xx4_c.fm STEAM GENERATOR & FLUID HEATER INSTALLATION MANUAL the SE coil assembly and the feedwater inlet, allowing it to rest on the main outer shell below. Using a set of self-locking clamps, Vise-Grip® pliers for example, clamp the SE outer shells to the main outer shell. b. Lift the remaining outer shell piece into place. Screw the two shell ends together. Align the assembled SE outer shells with the main outer shells below. c. Install the outer clamp bands around the main outer shell flange and the SE outer shell flange. Secure the clamp bands with their attaching hardware. d. Install the outer heater cover in the same manner as the inner heater cover was installed. Refer to steps f and g in the previous section. e. Install the patch plates around the feedwater inlet piping and the feedwater discharge piping. Install Piping a. Pre-assemble the SE Kit feedwater supply and feedwater discharge piping and flanges. b. Install the pre-assembled SE piping to the feedwater supply side and the feedwater discharge side of the machine, as shown in Figures 2 and 3. IMPORTANT Before starting the steam generator/fluid heater, verify all piping connections, outer shell assemblies, and clamp bands are secure. Check Completed SE Kit Installation a. Start and fill the heating unit without burner operation. See the filling procedure in Section IV of the Steam Generator/Fluid Heater Instruction Manual. b. Check for leakage around connections of the newly installed SE Kit piping. c. Boil out SE coil using soft water. See the “Conditioning of New Installations” procedure in Section III of the Steam Generator/Fluid Heater Instruction Manual. The machine should be ready to be placed into regular operation at this point. NOTE Some parameters of the control system may require adjustment with the added SE Kit. Consult your Clayton Service Representative for further details. Appndx_SE Option_xx4_c.fm D-26 04/22/2015 04/22/2015 SE154–SE504 FEEDWATER INLET–SE COIL FEEDWATER DISCHARGE–SE COIL FEEDWATER INLET–SE COIL SE604 FEEDWATER DISCHARGE–SE COIL Appendix D Figure 2 SE Kit completed hookup (rotated 90o counterclockwise) D-27 Appndx_SE Option_xx4_c.fm STEAM GENERATOR & FLUID HEATER INSTALLATION MANUAL FEEDWATER INLET–SE COIL FEEDWATER DISCHARGE–SE COIL SE704 Figure 3 SE Kit completed hookup, E704 Appndx_SE Option_xx4_c.fm D-28 04/22/2015 Back Cover 17477 Hurley Street, City of Industry, California 91744-5106, USA Phone: +1 (626) 435-1200 Fax: +1 (626) 435-0180 Internet: www.claytonindustries.com Email: [email protected]
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement