- Industrial & lab equipment
- Electrical equipment & supplies
- Bosch
- ICP-MAP0012
- Installation manual
- 2 Pages
Bosch ICP-MAP0012 CAN Splitter Module Installation Manual
Below you will find brief information for CAN Splitter Module ICP-MAP0012. This device is used for splitting the external Bosch Data Bus (BDB) into two independent and isolated stubs. This functionality allows you to connect keypads, gateways and further power supplies. The module is easy to install and configure, and features a housing made from ABS plastic that is off-white in color.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
▼
Scroll to page 2
1 | 2 | Safety Short information 4 4 | Bosch Data Bus connector B (BDB B) Optional hardware device splitting one Bosch Caution! Electricity Injuries due to electricity are possible. ! 3 | Switch off all electricity while installing the product. Do not open or modify this product, ex- Data Bus (BDB) into two independent and isol- Installation ated stubs to connect keypads, gateways and The mounting location of the module is on the further power supplies. hinged mounting plate. ICP-MAP0007 ICP-MAP5000 ICP-MAP0025 The following graphic shows an overview of the System overview hinged mounting plate and the designated mounting locations of the modules. cept if described in this manual. ICP-MAP0010 ICP-MAP0012 Old electrical and electronic appliances Electrical or electronic devices that are no longer serviceable must be collected separately Fig. 2: Hinged mounting plate overview and sent for environmentally compatible recyc- 1. ling (in accordance with the European Waste Slide the module onto the hinged mounting plate. Electrical and Electronic Equipment Directive). 4 To dispose of old electrical or electronic devices, you should use the return and collection systems put in place in the country concerned. 5 | 3 2 pair of rectangular openings on the bottom rail. 1 Bosch Data Bus connector (BDB) 2 Bosch Data Bus connector (BDB) 3 Bosch Data Bus connector A (BDB A) 2. 7 | Connect the cable of stub 1 to the connector BDB A on top of the module. 3. 1 Connect the cable of stub 2 to the connector BDB B on top of the module. ABS plastic Third Party License Statement Color off-white Copyright (C) 2010-2014 ARM Limited. All rights Maximum operating temperat16 VDC Maximum operating voltage in 29 VDC Data Bus to one of the two connectors (BDB) on the back of the module. met: – 60 in °C Rated current in mA 50 Minimum relative humidity in % 5 Redistributions of source code must retain the above copyright notice, this list of condi- -20 28 per stub Connect the cable of the external Bosch 55 Rated voltage in VDC ing plate forms, with or without modification, are permitted provided that the following conditions are in °C Maximum storage temperature Maximum output current in mA 900 1. Redistribution and use in source and binary -10 ure in °C Minimum storage temperature Fig. 3: Sliding the module onto the hinged mount- Connection reserved. Environmental ure in °C Electrical Minimum operating voltage in 8 | Housing material Minimum operating temperat- Technical data 3 Ensure that the locking clips snap into a Fig. 1: System overview 6 | 2 2. 1 tions and the following disclaimer. – Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. Maximum relative humidity in % 95 – Neither the name of ARM LIMITED nor the Usage indoor Mechanical Protection class IP30 dorse or promote products derived from this Dimension in cm (H x W x D) 15,9 x 8,3 x 6,4 Security level IK04 software without specific prior written per- Weight in g 168 Environmental class II names of its contributors may be used to en- mission. 9 | 10 | 11 | THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, MAP CAN Splitter Module BUT NOT LIMITED TO, PROCUREMENT OF ICP-MAP0012 SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) en Installation manual ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. 12 | 13 | 14 | Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.com © Bosch Sicherheitssysteme GmbH, 2015 | 2015.05 | 01 | F.01U.310.345
advertisement
Key Features
- Splits external Bosch Data Bus into two stubs
- Connects keypads, gateways and power supplies
- Easy to install and configure
- Housing material: ABS plastic
- Housing color: off-white
- Protection class: IP30
- Security level: IK04
- Environmental class: II
Frequently Answers and Questions
What is the purpose of the Bosch CAN Splitter Module?
The module splits the external Bosch Data Bus (BDB) into two independent and isolated stubs to connect keypads, gateways, and further power supplies.
Where is the Bosch CAN Splitter Module installed?
The module is installed on the hinged mounting plate.
What are the technical specifications for the Bosch CAN Splitter Module?
The module features a rated voltage of 28 VDC, rated current of 50 mA, maximum output current of 900 mA per stub, housing material of ABS plastic, housing color of off-white, a protection class of IP30, security level of IK04, and an environmental class of II.