Pelco SM5200, WS5080 Network Video Recorder Installation Manual

Pelco SM5200, WS5080 Network Video Recorder Installation Manual
Add to My manuals

Below you will find brief information for Network Video Recorder SM5200, Network Video Recorder WS5080. The Network Video Recorder SM5200 and Network Video Recorder WS5080 are designed for recording and managing video data from IP cameras. The units can be used to view live and recorded video, and also to manage camera settings and access control for cameras. They are designed for installation in either a rack or on a desktop.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Network Video Recorder SM5200, WS5080 Installation Manual | Manualzz

Endura

®

Hardware

For SM5200 and WS5080 Models

INSTALLATION MANUAL

C4687M-D | 12/14

Contents

Important Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Radio and Television Interference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Warranty Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Legal Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Video Quality Caution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Tools and Parts Required for Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Product Overview: Front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Product Overview: Rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Placing on a Desktop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Mounting Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Mounting in a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Installing the Drive Array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Connecting the Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Connecting an Uninterruptible Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Starting Up the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Shutting Down the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Orderly Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Immediate Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Connecting to the Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Migrating Data to a SM5200 from a SM5000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Important Notices

Regulatory Notices

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Radio and Television Interference

This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to Part 15 of the FCC Rules.

These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and the receiver.

• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

You may also find helpful the following booklet, prepared by the FCC: “How to Identify and Resolve Radio-TV Interference Problems.”

This booklet is available from the U.S. Government Printing Office, Washington D.C. 20402.

Changes and modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission’s rules.

This Class B digital apparatus complies with Canadian ICES-003.

Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.

Warranty Statement

For information about Pelco’s product warranty and thereto related information, refer to www.pelco.com/warranty.

Legal Notice

SOME PELCO EQUIPMENT CONTAINS, AND THE SOFTWARE ENABLES, AUDIO/VISUAL AND RECORDING CAPABILITIES, THE

IMPROPER USE OF WHICH MAY SUBJECT YOU TO CIVIL AND CRIMINAL PENALTIES. APPLICABLE LAWS REGARDING THE USE OF

SUCH CAPABILITIES VARY BETWEEN JURISDICTIONS AND MAY REQUIRE, AMONG OTHER THINGS, EXPRESS WRITTEN CONSENT

FROM RECORDED SUBJECTS. YOU ARE SOLELY RESPONSIBLE FOR INSURING STRICT COMPLIANCE WITH SUCH LAWS AND FOR

STRICT ADHERENCE TO ANY/ALL RIGHTS OF PRIVACY AND PERSONALTY. USE OF THIS EQUIPMENT AND/OR SOFTWARE FOR ILLEGAL

SURVEILLANCE OR MONITORING SHALL BE DEEMED UNAUTHORIZED USE IN VIOLATION OF THE END USER SOFTWARE AGREEMENT

AND RESULT IN THE IMMEDIATE TERMINATION OF YOUR LICENSE RIGHTS THEREUNDER.

3

4

Video Quality Caution

Frame Rate Notice Regarding User Selected Options

Pelco systems are capable of providing high quality video for both live viewing and playback. However, the systems can be used in lower quality modes, which can degrade picture quality, to allow for a slower rate of data transfer and to reduce the amount of video data stored. The picture quality can be degraded by either lowering the resolution, reducing the picture rate, or both. A picture degraded by having a reduced resolution may result in an image that is less clear or even indiscernible. A picture degraded by reducing the picture rate has fewer frames per second, which can result in images that appear to jump or move more quickly than normal during playback.

Lower frame rates may result in a key event not being recorded by the system. Judgment as to the suitability of the products for users' purposes is solely the users' responsibility. Users shall determine the suitability of the products for their own intended application, picture rate and picture quality. In the event users intend to use the video for evidentiary purposes in a judicial proceeding or otherwise, users should consult with their attorney regarding any particular requirements for such use.

Package Contents

Figure 1: Package Contents

1 System Hardware

2 USB Key: Might include installer software, a recovery image, and the installation and operation manuals.

3 Accessory Pack

4 Hard Drive Pack (hard drives in carriers)

5 Standard USB Keyboard (1 ea. for workstation models only)

6 Rack Mount Kit (1 ea.)

5

6

Figure 2: Accessory Pack Contents

1 Standard USB Mouse (1 ea.)

2 Bezel Keys (2 ea.)

3 Standard US Power Cord (1 ea.)

4 Power Cord (based on country designation, 1 ea.)

NOTE

: Units shipped to China do not include power cords.

5 Chassis Handles (2 ea.); includes Phillips screws for installation.

6 Rubber Feet (4 ea.)

Figure 3: Rack Mount Kit Contents

1 Sliding Mounting Brackets (2 ea.)

2 Rear Mount Rails (2 ea.), Front Mount Rails (2 ea.)

3 L-Shaped Plate Nuts (4 ea.)

4 M5*8L-H2.5 Round Head Nickel Screws (18 ea.), M4*6L-H2.5 Round Head Nickel Screws (18 ea.), 4.2*11*0.8

Nickel Washers (10 ea.)

Tools and Parts Required for Installation

The following installation tools and parts are needed for installation, but are not supplied.

• Power source (110/220 VAC)

• Small Phillips screwdriver, if mounting the unit into a rack

7

8

Product Overview: Front

Figure 1: Server Models: Front Panel Layout (Bezel Open)

Figure 2: Workstation Models with-DVD: Front Panel Layout (Bezel Open)

Figure 3: Front Bezel Indicators (Bezel Closed)

1

Unit Status

Green: The unit is functioning normally.

Flashing green: The unit is starting or shutting down.

Amber: The unit is nearing operational thresholds; maintenance is recommended.

Red: The unit is in an error condition.

2

Network Port 1 Speed and Activity

Off: The unit is not connected to the network.

Solid green: The unit is connected to the network using the 1000Base-T standard.

Solid amber: The unit is connected to the network using the 100Base-T standard.

Solid red: The unit is connected to the network using the 10Base-T standard.

NOTE

: Use the 1000Base-T standard.

3

Network Port 2 Speed and Activity

Off: The unit is not connected to the network.

Solid green: The unit is connected to the network using the 1000Base-T standard.

Solid amber: The unit is connected to the network using the 100Base-T standard.

Solid red: The unit is connected to the network using the 10Base-T standard.

NOTE

: Use the 1000Base-T standard.

4

Software Status

Green: The software is operating normally.

Amber: A minor software malfunction is detected (for example, an excessive network packet loss).

Red: A fatal software error has occurred (for example, ceasing to record).

5

Power Button

• Push the power button to turn the unit on or off.

• Push and hold the power button for a hard shutdown.

6

Drive Status

Flashing green: The read or write activity on a specific hard drive.

Solid red: A problem exists with the hard drive.

Flashing green/red: The unit is initializing the hard drive

7

USB Ports

The unit has five USB ports: one on the front panel (USB 2.0 port) and four on the rear panel (two USB 3.0 and two USB 2.0 ports).

Use these ports to connect a UPS unit, or conduct diagnostic and troubleshooting activities.

9

Product Overview: Rear

Figure 1: Rear Panel Layout

3

4

1

2

11

12

9

10

13

7

8

5

6

Rear Chassis Fan

Power Receptacle

VGA Port

Ethernet Ports

• Network Port 1 (left is primary)

• Network Port 2 (right is secondary)

Expansion Slots

Serial Ports

Reserved (do not use)

Audio Output

Audio Input

USB 3.0 Ports

USB 2.0 Ports

DisplayPort Connectors

Digital Visual Interface (DVI) Connector

Placing on a Desktop

WARNING

: Do not place the unit on its side; in this position, the unit is likely to fall over and may cause equipment damage or personal injury.

1.

Verify that the rubber feet are attached to the bottom of the unit. If not, secure the rubber feet to the bottom of the unit.

2.

Position the unit to allow for cable and power cord clearance at the rear.

10

Mounting Requirements

The unit can be mounted in an industry standard 48 cm (19-inch) equipment rack and occupies two rack units (RU) of vertical rack space

(8.9 cm or 3.5 inches). The hardware necessary to mount the unit into a rack is supplied with the unit.

NOTE

: The unit must be placed on a desktop to install an optional 4-port capture card, a RAID controller card, or a SCSI card. Make sure these cards are installed properly and performing as expected before placing the unit in the rack.

The rack must meet the following requirements:

Rack standard:48 cm (19 in.), EIA-310-D compliant (rear column required)

Rack column depth:50.8 to 76.2 cm (20 to 30 in.)

Column mounting hole provisions:10-32 UNF-2B threaded holes or square window holes on front and rear columns

Door systems (optional): Front doors must have at least 5.1 cm (2 in.) between the unit bezel and the inside of the door. Rear doors may be used only on rack columns that are more than 66 cm (26 in.) deep.

Mounting in a Rack

Do not block slots and openings in the cabinet. These provide ventilation to prevent the unit from overheating. Never place the unit near or over a radiator or heat register. When placing the unit in a rack, be sure to provide proper ventilation.

1.

Install the chassis handles: a.

Align the screw holes on the chassis handles and the chassis.

b.

Insert and tighten the four 10-32 x 0.5-inch Phillips flat head screws with a Phillips screwdriver.

2.

Remove the chassis brackets from the sliding brackets: a.

Slide each chassis bracket away from the sliding bracket until it locks in place.

b.

Press the release lever up or down (depending on the rail) to release the chassis bracket from the sliding bracket. Press down on the release lever for the right set of rails and press up for the left set of rails.

Figure 1: Remove the Chassis Brackets from the Sliding Brackets

11

12

3.

Attach one chassis bracket to each side of the unit. Use four M4*6L-H2.5 round head nickel screws for each bracket. Attach the chassis brackets so that the slotted ends are positioned toward the rear of the unit.

Figure 2: Attach the Mounting Brackets

4.

If necessary, remove the rubber feet from the underside of the unit.

5.

Attach a front and rear L-shaped bracket to the left and the right sliding brackets using two M4*6L-H2.5 round head nickel screws.

Leave all eight of the screws untightened.

Figure 3: Attach the L-Shaped Mounting Brackets

6.

Attach the front and rear L-shaped brackets to the rack. Make sure the rails are mounted back to back. Use two M5*8L-H2.5 round head nickel screws for each bracket.

The mounting brackets are identical and can be used on either side of the rack.

a.

Position the ear of the front L-shaped bracket and an L-shaped plate nut against the inside front of the equipment rack. Align the two center holes in the ear of the L-shaped bracket and L-shaped plate nut with the holes in the rack.

b.

Using two M5*8L-H2.5 round head nickel screws, insert and tighten the screws from the outside of the rack, pointing toward the back of the rack.

c.

Adjust the rails to the correct depth of the equipment rack by sliding the rear-mount rail to the back of the equipment rack.

d.

Repeat the previous steps to attach the rear L-shaped bracket and L-shaped plat nut to the rack.

Figure 4: Attach the Brackets to the Rack

7.

Tighten the M4*6L-H2.5 round head nickel screws that are attached to the front- and rear-mount rails which were left untightened earlier in the installation.

8.

Place the unit onto the mount rails by sliding the chassis brackets onto the rails. Align the chassis brackets with the first slot on the sliding brackets when installing the unit. This will ensure that the two brackets are aligned properly when sliding the unit in and out of the rack. It might require two people to lift and slide the unit into place.

NOTE

: To pull the unit completely out of the rack, pull the unit out of the sliding bracket until it locks into place, and then press the release levers on either side of the chassis bracket to release the unit.

Figure 5: Install the Unit in the Rack

Figure 6: Align the Chassis Bracket and the Sliding Bracket

9.

Insert and tighten two M5*8L-H2.5 round head nickel screws above and below the chassis handles to secure the unit in the rack.

13

Installing the Drive Array

Drives and drive bays are numbered 1 through 6. You must install the drives in their corresponding bays in numerical order.

When replacing a drive in a RAID array, you should rebuild the array before operating. If another drive fails before the array is rebuilt, the array will go off line and data loss will occur.

WARNING

: The hard drive parts and assemblies are susceptible to damage by Electrostatic Discharge (ESD). Follow safe handling procedures when replacing hard drives.

Figure 1: Drive Bay Allocation for Models with 6 Bays

1 SSD; contains the OS

2 SSD; RAID 1 OS

3 HDD; RAID 5 Export Storage

4 HDD; RAID 5 Export Storage

5 HDD; RAID 5 Export Storage

6 HDD; RAID 5 Export Storage

Figure 2: Drive Bay Allocation for Models with DVD Drive

1 SSD: Contains operating system, install first

2 HDD: for additional storage (optional)

3 HDD: for additional storage (optional)

4 HDD: for additional storage (optional)

5 DVD drive

14

1.

Unlock and open the bezel.

2.

Install the drive carriers: a.

Open the drive latch (grasp the latch right side and pull it to the left).

b.

Slide the drive carrier into the drive bay.

c.

Close the hard drive latch; ensure that the drive carrier locks into place.

3.

Close and lock the bezel.

15

Connecting the Power Supply

1.

Connect the power cord to the unit’s power connector.

2.

Connect the other end of the power cord to the appropriate power source.

Connecting an Uninterruptible Power Supply

While UPS units supply backup battery power, the unit works in conjunction with the SmartUPS from APC. The SmartUPS signals the unit to begin a graceful shutdown if the UPS standby power falls below a specific threshold.

1.

Shut down the unit.

2.

Connect a power cord from the unit power supply to a standard wall outlet.

3.

Connect a power cord from the UPS to a standard wall socket or other power source.

4.

Connect a USB cable from the APC SmartUPS to the USB connector on the unit.

5.

Turn on the UPS.

6.

Turn on the unit.

USB

POWER SOURCE

OUTPUT POWER

INPUT POWER

UPS

Figure 1: Connecting a UPS

16

Starting Up the Unit

1.

Unlock and open the bezel.

2.

Press the power button.

3.

Close and lock the bezel.

Shutting Down the Unit

Use an orderly shutdown for the unit to close files and power down.

Use the immediate shutdown in an emergency or when there is not enough time for an orderly shutdown.

Orderly Shutdown

1.

Click Start.

2.

Click Shut Down.

Immediate Shutdown

1.

Unlock and open the bezel.

2.

Press and hold the power button until the unit shuts down.

3.

Close and lock the bezel.

17

Connecting to the Network

The primary network interface card (NIC) must be active when using the License Key Entry program to add or update IP camera licenses.

1.

Connect one end of an Ethernet cable one of the unit’s network interfaces.

2.

Connect the other end of the cable to an available Gigabit Ethernet port.

NETWORK

SECONDARY

Figure 1: Network Cable Connection

18

Migrating Data to a SM5200 from a SM5000

You must configure the network interface and DHCP settings on the SM5200 to match the settings from the SM5000 before performing the migration process, or you will lose these settings in the migration process.

For a quick and seamless transition to a new system manager, you can transfer your database and settings from your existing SM5000 to a new SM5200.

The migration process requires a flash drive with an empty boot record and a Windows-based client on the Endura network with Endura

Utilities version 2.3.3 or later installed. It is recommended that you use the Pelco flash drive included with your SM5000 for data migration.

Data migration does not include primary network interface settings or settings for features new and specific to the SM5200. You must manually configure these settings.

Do not replace your existing system manager until your SM5200 is fully configured and operational. Only the admin user can log on to the SM5200. If the admin user exists in the database you are migrating to the SM5200, the user will login to the SM5200 using his or her current password. If the admin user does not exist before migration, then the admin user will login using the default password.

1.

Connect your Pelco flash drive to a Windows-based client on the Endura network.

2.

Open Endura Utilities.

3.

Right-click SM5000 in the System Attributes tab.

4.

Select SM Backup.

5.

Select the flash drive as the backup location and click OK. This creates a folder on the flash drive named the IP address of the

SM5000 you are backing up. The folder will contain a UtilitiesBackup.tgz file.

6.

Copy UtilitiesBackup.tgz to the root directory of the flash drive.

7.

Remove the flash drive from the client computer, and connect it to the SM5200.

8.

Turn on the SM5200. After a short boot process, the four lights on the right side of the unit’s front panel turn solid amber, indicating that the system is importing UtilitiesBackup.tgz. This process may take several minutes.

9.

Remove the flash drive when the software status light turns off, indicating that the migration process is complete. The SM5200 restarts 30 seconds after the migration process has completed. Remove the flash drive within 30 seconds of the completed migration process or once the unit has fully rebooted; do not remove the flash drive during the boot process.

NOTE

: Upon completing the migration process, the SM5200 creates a file called .sm5000-migrated in the root directory of the flash drive, preventing the SM5200 from attempting to import UtilitiesBackup.tgz multiple times.If data fails to migrate properly, or you want to reuse the flash drive to perform the migration process on another SM5200, delete the.sm5000-migrated file.

19

Technical Specifications

Hardware

Processor

Internal Memory

SM5200

WS5080

Operating System

SM5200

WS5080

Storage

SSD

HDD

Drive Bays

SM5200

WS5080

Optical Drive

USB Ports

Intel ® Xeon ® E3-1275 v3

16 GB DDR3 RAM ECC

8 GB DDR3 RAM Non-ECC

Embedded Linux

Windows 7 Ultimate 64-bit SP1

120 GB (OS)

4 TB

6 (2 SSD in RAID1, up to 4 HDD)

4 (1 SSD, 3 Unused)

DVD±RW (WS5080 only)

3 USB 2.0 ports (1 front, 2 rear), 2 USB 3.0 ports (rear)

Video

Video System

Max Resolution

Video Outputs

Video Standards

Video Decoding Supported

Video Display Modes

Decoding Performance

Intel HD Graphics P4700 (shared memory)

3840 x 2160 per DisplayPort output (2x)

1920 x 1200 @ 60 hz on DVI-D output

1920 x 1200 @ 60 hz on VGA output

Supports up to 3 simultaneous displays using any combination of the four outputs

60 Hz capable for NTSC

75 Hz capable for PAL

MPEG-4 ASP; H.264 Baseline, Main, and High profiles

1 image, 4 images (2 x 2), 9 images (3 x 3), 16 images (4 x 4), 6 images (1 large + 5 small), 10 images (2 large + 8 small), 13 images (1 large + 12 small); High definition monitors can also display 6 images (3 x 2) and 12 images (4 x 3)

16X real-time MPEG-4 streams at 704 x 480; 12X real-time H.264 Baseline profile streams at 704 x 480;

4X H.264 Baseline profile streams at 720p; 2X real-time H.264 Baseline profile streams at 1080p

Audio

Audio Decoding

Audio Bit-rate

Audio Levels

Input

Output

Audio Connectors

Connector Tip

Connector Ring

20

G.711 speech codec

64 kbps

Electret microphone

Up to 3 Vp-p, adjustable, minimum load of 8 ohms

2, 3.5 mm stereo jacks

Signal left (input and output)

Signal right (input and output)

Audio

Connector Sleeve

Audio Inputs

Audio Outputs

Network

Interface

Common

Microphone

Speaker or line out

2 Gigabit Ethernet RJ-45 port (1000Base-T)

Front Panel

Buttons

Indicator

Unit Status

Primary Network

Secondary Network

Software Status

Hard Disk Status

Green, amber, red

Green, amber, red

Green, amber, red

Green, amber, red (based on diagnostics)

Green, red, off (behind bezel)

Power

Power Input

Power Supply

Power Consumption

100 VAC

115 VAC

220 VAC

100 to 240 VAC, 50/60 Hz, autoranging

Internal

Operating Maximum

160 W, 1.60 A, 547 BTU/H

160 W, 1.39 A, 547 BTU/H

160 W, 0.72 A, 547 BTU/H

Environmental

Operating Temperature

Storage Temperature

Operating Humidity

Maximum Humidity Gradient

Operating Altitude

10° to 35°C (50° to 95°F) at unit air intake (front of unit)

–40° to 65°C (–40° to 149°F)

20% to 80%, noncondensing

10% per hour

–15 to 3,048 m (–50 to 10,000 ft)

Operating Vibration 0.25 G at 3 Hz to 200 Hz at a sweep rate of 0.5 octave/minute

NOTE

: The temperature at the unit air intake can be significantly higher than room temperature. Temperature is affected by rack configuration, floor layout, air conditioning strategy, and other issues. To prevent performance failure and unit damage, make sure the temperature at the unit is continuously within the operating temperature range.

Physical

Construction

Finish

Front Panel

Chassis

Dimensions

Steel cabinet

Gray metallic with black end caps

Black matte finish

50.8 x 43.4 x 8.9 cm (20" D x 17.1" W x 3.5" H)

21

Physical

Mounting Desktop (feet) or rack (2 RU per unit)

SM5200 Models

Use the following table to create a model number for your SM5200. For example, the model number for an SM5200 with 4 TB of storage and a United Kingdom power cord would be SM5200-04-UK.

Model Storage Country Code

4 TB US = North America

Description

SM5200

16 TB

AU = Australia

AR = Argentina

EU = Europe

UK = United Kingdom

SM5200 hardware/software with regional power cord

CN = China

SM5200 hardware/software without power cord. Units shipped to China do not include a power cord.

WS5080 Models

Use the following table to create a model number for your WS5080. For example, the model number for a WS5080 workstation with a

United Kingdom power cord would be WS5080-UK.

Model Country Code

US = North America

Description

WS5080

AU = Australia

AR = Argentina

EU = Europe

UK = United Kingdom

WS5080 hardware/software with regional power cord

CN = China

WS5080 hardware/software without power cord. Units shipped to China do not include a power cord.

Supplied Accessories

Keyboard

Mouse

USB Drive containing Resource and Recovery materials

Windows 7 Ultimate Disc with License (WS5080 Only)

Rack Mount Kit

Power Cord

NOTE

: Units shipped to China do not include power cords.

Optional Software Accessories

WS5200-MAP Endura Mapping interface

Certifications

CE, Class A

FCC, Class A

UL/cUL Listed

22

Certifications

S-Mark for Argentina

CCC

C-Tick

Standards/Organizations

Pelco is a member of the MPEG-4 Industry Forum

Pelco is a member of the Universal Plug and Play (UPnP) Forum, Steering Committee

Pelco is a member of the Universal Serial Bus (USB) Implementers Forum

Pelco is a contributor to the International Standards for Organization / Electrotechnical Commission (ISO/IEC) Joint Technical Committee 1

(JTC1), “Information Technology,” Subcommittee 29, Working Group 11

Compliance, ISO/IEC 14496 standard (also known as MPEG-4)

Compliance, International Telecommunication Union (ITU) Recommendation G.711, “Pulse Code Modulation (PCM) of Voice Frequencies”

23

Pelco by Schneider Electric

3500 Pelco Way Clovis, California 93612 USA

(800) 289-9100 Tel (800) 289-9150 Fax

+1 (559) 292-1981 International Tel

+1 (559) 348-1120 International Fax

www.pelco.com

Pelco, the Pelco logo, and other trademarks associated with Pelco products referred to in this publication are trademarks of Pelco, Inc. or its affiliates.

ONVIF and the ONVIF logo are trademarks of ONVIF Inc. All other product names and services are the property of their respective companies.

Product specifications and availability are subject to change without notice.

© Copyright 2014, Pelco, Inc.

All rights reserved.

advertisement

Key Features

  • 6 Drive Bays (SM5200)
  • 4 Drive Bays (WS5080)
  • DVD±RW drive (WS5080 only)
  • Supports up to 3 simultaneous displays
  • Intel® Xeon® E3-1275 v3 Processor
  • 16 GB DDR3 RAM ECC (SM5200)
  • 8 GB DDR3 RAM Non-ECC (WS5080)
  • MPEG-4 ASP; H.264 Baseline, Main, and High profiles decoding
  • G.711 speech codec decoding
  • 2 Gigabit Ethernet RJ-45 port (1000Base-T)

Frequently Answers and Questions

What is the maximum resolution of the SM5200 and WS5080 models?
The maximum resolution is 3840 x 2160 per DisplayPort output (2x), 1920 x 1200 @ 60 hz on DVI-D output and 1920 x 1200 @ 60 hz on VGA output.
What video standards are supported by the SM5200 and WS5080 models?
The models are capable of 60 Hz for NTSC and 75 Hz for PAL video standards.
What is the maximum operating temperature for the SM5200 and WS5080 models?
The operating temperature range is 10° to 35°C (50° to 95°F) at unit air intake (front of unit).