KTR NVT-E Series Operating And Assembly Instructions Manual
PDF
Document
Advertisement
Advertisement
KTR Kupplungstechnik GmbH D-48407 Rheine NVT-E Operating-/Assembly Instructions KTR-N Sheet: Edition: NVT-E Operating-/Assembly Instructions Please note protection mark ISO 16016. Drawn: Verified: 11.10.12 Pz/Wy 19.11.12 Pz Replaced for: Replaced by: --- 42611 EN 1 of 27 1 KTR Kupplungstechnik GmbH D-48407 Rheine NVT-E Operating-/Assembly Instructions KTR-N Sheet: Edition: 42611 EN 2 of 27 1 The series of level switches NVT-E is suitable for monitoring level and temperature in tanks in fluid systems. Depending on the model, the level switches are equipped with a different number of switching outputs. Please find the configuration on the type plate. Here you find the order acknowledgement number, the product key and the model description. Table of Contents 1 Technical Data 2 Hints 2.1 2.2 2.3 2.4 3 Assembly 3.1 4 General Hints Safety and Advice Hints General Hints to Danger Proper Use Starting (General) Operation 4.1 4.2 4.3 4.4 4.5 4.6 4.7 Switching On LED-Status Display Key Functions Key Lock Active Summary of Menu Amendment of Basic Settings 4.6.1 Defining Charging Level 4.6.2 Defining Temperature 4.6.3 Re-assignment of Switching Outputs 4.6.4 Setting Updating Rate of Display 4.6.5 Activating/Deactivating Key Lock 4.6.6 Scaling of Charging Level 4.6.7 Maximum Displayed Value of Charging Level 4.6.8 Minimum Displayed Value of Charging Level 4.6.9 Resetting Factory Settings (Reset) 4.6.10 Factory Settings Switching Outputs 4.7.1 Definition of Switching Characteristics 4.7.2 Upper Switching Limit (Set Point) 4.7.3 Lower Switching Limit (Reset Point) 4.7.4 Delay for Set Point 4.7.5 Delay for Reset Point 4.7.6 Testing the Switching Output 4.7.7 Changing Display Function of Status LED Please note protection mark ISO 16016. Drawn: Verified: 11.10.12 Pz/Wy 19.11.12 Pz Replaced for: Replaced by: --- KTR Kupplungstechnik GmbH D-48407 Rheine NVT-E Operating-/Assembly Instructions KTR-N Sheet: Edition: Table of Contents 4.8 4.9 Analogue Outputs 4.8.1 Assignment of Upper Limit 4.8.2 Assignment of Lower Limit 4.8.3 Defining the Type of Signal 4.8.4 Testing the Analogue Output Diagnostics 4.9.1 Opening the Journal 4.9.2 Maximum/Minimum Charging Level 4.9.3 Maximum/Minimum Temperature 4.9.4 Assigning the Switching Output for Recording 4.9.5 Delay for Min./Max. Saving (Charging Level) 4.9.6 Delay for Min./Max. Saving (Temperature) 5 Spares Inventory, Customer Service Addresses 6 Disposal 7 Maintenance and Service 7.1 Breakdowns, Causes and Elimination Please note protection mark ISO 16016. Drawn: Verified: 11.10.12 Pz/Wy 19.11.12 Pz Replaced for: Replaced by: --- 42611 EN 3 of 27 1 KTR Kupplungstechnik GmbH D-48407 Rheine NVT-E Operating-/Assembly Instructions KTR-N Sheet: Edition: 42611 EN 4 of 27 1 1 Technical Data Technical Data Operating pressure: Operating temperature: Ambient temperature: Weight: Sealing fluid: Swimmer: Immersion pipe: G 3/4 flange: Multiplier: Resolution: Temperature sensor: Max. 1 bar -20 °C to +80 °C -20 °C to +70 °C approx. 400g Min. 0,8 kg/dm3 PU MS MS Reed chain 10 mm PT100 class B DIN 60751 Displap and control unit Display: Operation: Memory: Current consumption with starting: Current consumption during operation: Supply voltage (UB): Protection: Display units: Setting range: Accuracy: 4-digit 7-segment LED display over 3 keys Min. and max. value memory approx. 100 mA for 100 ms approx. 50 mA 10-32 V DC (nominal voltage 24 V DC) IP 65 Level: %, cm, L, i, Gal Temperature: -20 °C to +120 °C or -4 °F to 248 °F Level: e. g. 0-100 %l Temperature: 0 °C to +100 °C or 32 °F to 212 °F 1 % of final value Illustration 1 Table 1: Pin assignment Types NVT-E…-2S NVT-E …-4S PNP transistor output Analogue output – level Analogue output – temperature 2 times ----- 4 times ----- Types NVT-E …-2S-KN-KT NVT-E …-4S-KN-KT PNP transistor output Analogue output – level Analogue output – temperature 2 times 1 time 1 time 4 times 1 time 1 time Please note protection mark ISO 16016. Drawn: Verified: 11.10.12 Pz/Wy 19.11.12 Pz Replaced for: Replaced by: --- KTR Kupplungstechnik GmbH D-48407 Rheine NVT-E Operating-/Assembly Instructions KTR-N Sheet: Edition: 42611 EN 5 of 27 1 2 Hints 2.1 General Hints Please read through these mounting instructions carefully before you set the level and temperature control into operation. The mounting instructions are part of your product. Please keep them carefully and close to the level and temperature control. 2.2 Safety and Advice Hints STOP DANGER! Danger of injury to persons. ! CAUTION! Damages on the machine possible. ATTENTION! Pointing to important items. 2.3 General Hints to Danger STOP DANGER! With assembly, operation and maintenance of the level and temperature control it has to be made sure that the entire drive train is protected against unintentional engagement. You can be seriously hurt by rotating parts. Please make absolutely sure to read through and observe the following safety instructions. All operations on and with the NVT-E have to be performed taking into account "safety first". Please make sure to disengage the power pack before you perform your work on the NVT-E. Protect the power pack against unintentional engagement, e. g. by providing hints at the place of engagement or removing the fuse for current supply. Do not touch the operation area of the machine as long as it is in operation. Please protect the rotating drive components against unintentional touch. Please provide for the necessary protection devices and caps. 2.4 Proper Use You may only assemble, operate and maintain the NVT-E if you carefully read through the mounting instructions and understood them had technical training are authorized to do so by your company The NVT-E may only be used in accordance with the technical data (see chapter 1). Unauthorized modifications on the NVT-E design are not admissible. We do not take any warranty for resulting damages. To further develop the product we reserve the right for technical modifications. The level and temperature control (NVT-E) described in here corresponds to the technical status at the time of printing of these mounting instructions. Please note protection mark ISO 16016. Drawn: Verified: 11.10.12 Pz/Wy 19.11.12 Pz Replaced for: Replaced by: --- KTR Kupplungstechnik GmbH D-48407 Rheine NVT-E Operating-/Assembly Instructions KTR-N Sheet: Edition: 42611 EN 6 of 27 1 3 Assembly The level switches are supplied fully assembled and can be fixed to the tank by means of the thread. In this context please make sure that the float can move freely and sufficient distance to the tank walls and to other equipment is kept. If the float has potentially been disassembled it has to be made sure that the magnet inside the float is situated above the fluid level. This can easily be inspected by means of a piece of iron which allows to find out the position of the magnet in the float. 3.1 Starting (General) ! CAUTION! The electric connection may be performed by trained technical staff only. Connection The mains voltage is connected to connector S6 or M12, respectively. Nominal voltage of devices is 24 V DC. Please refer to the mounting dimensions and pin assignment in the chapter 1 Technical Data. The switching outputs are designed as PNP transistor outputs (see illustration 2). ATTENTION! If the switching output is measured with high-impedance measuring equipment or if the frequency output is used, connect a 10 k resistor between output and ground to avoid faulty measurements. Illustration 2 4 Operation 4.1 Switching On If an error message occurs during normal operation, please refer to chapter 7.1 Breakdowns, Causes and Elimination. After connecting the device to the mains, the software version is displayed for a short time. Afterwards, the measured values are displayed. The functions of the display- and control unit are explained in the following chapters. Illustration 3 Please note protection mark ISO 16016. Drawn: Verified: 11.10.12 Pz/Wy 19.11.12 Pz Replaced for: Replaced by: --- KTR Kupplungstechnik GmbH D-48407 Rheine NVT-E Operating-/Assembly Instructions KTR-N Sheet: Edition: 42611 EN 7 of 27 1 4 Operation 4.2 LED-Status Display Light emitting diodes above the reading indicate the switching status of the outputs. The LEDs are assigned to the switching output numbered the same. ATTENTION! The table 2 shows the factory settings as level or temperature output. Table 2: LED-Status display LED-Display LED 1 – yellow indicates switching output 1 LED 2 – red indicates switching output 2 LED 3 – yellow indicates switching output 3 LED 4 – red indicates switching output 4 2 switching outputs 4 switching outputs Level Level Temperature Level --- Temperature --- Temperature ATTENTION! The switching behavior of the LED (ON with closed or opened switching output) can be changed, please note chapter 4.7 switching outputs. 4.3 Key Functions Operation is performed via the keys underneath the display. Table 3: Key functions Key - Operation mode Measured value display: Function Switching the displayed units (example): () - Within the menu: At the end of the menu: - After input/selection: - Measured value display: Within the menu: - Measured value display: Within the menu: - Within the menu: - Within the menu: Within the menu: +* +* 60 s no action * Switching to a submenu Switching to a superordinate menu (Exit) indicates the end of the menu Accepting and saving a value entered or a feature selection Displaying the configuration Scrolling up the menu item, value or feature selection. Holding the key changes the value continuously. Switching to the main menu Scrolling down the menu item, value or feature selection. Holding the key changes the value continuously. Exiting the main, sub or optional menu and returning to measured value display Switching to the superior menu level Exiting the main, sub or optional menu * The values that were modified are not stored if you exit the optional or setting menu. ATTENTION! A detailed explanation of the menu control is listed in the following chapters. Please note protection mark ISO 16016. Drawn: Verified: 11.10.12 Pz/Wy 19.11.12 Pz Replaced for: Replaced by: --- KTR Kupplungstechnik GmbH D-48407 Rheine NVT-E Operating-/Assembly Instructions KTR-N Sheet: Edition: 42611 EN 8 of 27 1 4 Operation 4.3 Key Functions To select a menu item and set the values please proceed as follows: Open the main menu via the key . Select the submenu via the keys and and open the submenu via the key . If applicable, select the next submenu via the keys and and open it using the key . Select the requested menu item via the keys and and open the parameter list via the key . Set the value using the keys and and accept via the key . The amended settings are saved and the device returns to the submenu. Exit the submenu by selecting menu item EXIT and press key to accept. The device returns to the superordinate menu or measured value display, respectively. 4.4 Key Lock Active If the key lock is activated, retrieving the menu via key shows the display instead of the main menu. The active digit is indicated by a dot. Enter the code via the keys and and press the key to accept. The active digit shifts to the right by one place. Having entered the 3rd digit the main menu is opened. ATTENTION! Having entered an incorrect code, the device returns to measured value display. If you have lost the password, enter the master code 287 to return to the menu. To unlock the key lock, reset the password to the input 000 in the menu item Settings Extended Functions . in the sub-menu Basic 4.5 Summary of Menu The menu structure is based on the VDMA standard 24574 and following. The menu has a hierarchy structure. The highest menu level includes input of the main menu, e. g. , , , . Each main menu comprises further submenu items. , The menu items may vary depending on the configuration of the device. Your device may not provide all menu items described below. You can retrieve the configuration by pressing the key in the display mode. A 4-digit code is displayed, e. g.: Meaning of the 4-digit code tsav: t: Type s: number of switching outputs a: number of analogue outputs v: mounting of device Please note protection mark ISO 16016. Drawn: Verified: 11.10.12 Pz/Wy 19.11.12 Pz t = temperature measurement o = level and temperature measurement 2 or 4 0 or 2 i = standard mounting (installation of tank) Replaced for: Replaced by: --- KTR Kupplungstechnik GmbH D-48407 Rheine NVT-E Operating-/Assembly Instructions KTR-N Sheet: Edition: 42611 EN 9 of 27 1 4 Operation 4.5 Summary of Menu The different menu items are not displayed if the option is not available. Example: With a=0 the menu items for setting the analogue output are not available. In this case you may skip the description of these items. The structure of the main menu charging level ( ) and temperature ( ) are identical. These menus include all settings for the switching outputs or the analogue outputs (if available). The basic settings of the device may be changed. General settings are set in the menu Basic settings extended functions ( ). These settings should be performed first, since they affect displays and settings in the different menus. General settings are, for example, the units used and the classification of the switching outputs for measurement of charging level and temperature. The classification of the analogue outputs cannot be changed. In addition the menu Diagnostics provides options of diagnostics. Illustration 4 ATTENTION! A detailed explanation of the overall menu structure is shown at the end of these operating/assembly instructions. 4.6 Amendment of Basic Settings The menu Basic settings extended functions ( ) comprises general basic settings. These settings affect the display of values in the measured value display as well as the options of settings in the menus charging level and temperature. It is possible to change the assignment of switching outputs for measurement of charging level and temperature (if available), too. Press the key to open the main menu. Select the menu item Please note protection mark ISO 16016. Drawn: Verified: via the keys and and open the menu via the key . 11.10.12 Pz/Wy 19.11.12 Pz Replaced for: Replaced by: --- KTR Kupplungstechnik GmbH D-48407 Rheine NVT-E Operating-/Assembly Instructions KTR-N Sheet: Edition: 42611 EN 10 of 27 1 4 Operation 4.6 Amendment of Basic Settings 4.6.1 Defining Charging Level In this menu the displayed unit symbol for the charging level is defined. The following menu items are available: Per cent Optional settings: [ , , , , , ] cm Inch Litre Gallons None Please note: If „no unit“ is selected, the measured values are scaled to a 4-digit display. The measured values are not automatically converted. Having converted the unit the measurement range should be scaled, if necessary (see menu charging level and ). 4.6.2 Defining Temperature In this menu the displayed unit symbol for temperature is defined. The following menu items are available: Degrees Celsius Degrees Fahrenheit Please note: If changing the setting, all corresponding settings such as setting of switching points are amended accordingly. Please note protection mark ISO 16016. Drawn: Verified: 11.10.12 Pz/Wy 19.11.12 Pz Replaced for: Replaced by: --- KTR Kupplungstechnik GmbH D-48407 Rheine NVT-E Operating-/Assembly Instructions KTR-N Sheet: Edition: 42611 EN 11 of 27 1 4 Operation 4.6 Amendment of Basic Settings 4.6.3 Re-assignment of Switching Outputs The amendment of assignment of the switching outputs is described here based on the example of switching output 1. The switching outputs 1 to n can be assigned optionally to the measuring size charging level or temperature. The assignment affects the appearance of the menu charging level and temperature . In the factory setting the switching output OUT 1 is assigned to the charging level. Example: OUT 1 shall be assigned to temperature. For that purpose must be set to . As a result the setting menu is shifted from the menu charging level to the menu temperature. The procedure for amending the settings does not change. ATTENTION! With a re-assignment of the switching outputs all corresponding settings have to be verified. The figures set before are not automatically adapted. The assignment of LEDs for status display does not change. The following menu items are available: Measurement of charging level Measurement of temperature ATTENTION! The other switching outputs for measurement of charging level of temperature are assigned in the same way as switching output 1. Perform the same steps as described for switching output OUT 1. 4.6.4 Setting Updating Rate of Display Depending on the application the updating rate of the dispay can be set. The display can be fully switched off as well. The function of LED continues to be existing. The following menu items are available: fast medium slow display off Please note: Problem reports continue to be indicated in spite of the display being switched off. Please note protection mark ISO 16016. Drawn: Verified: 11.10.12 Pz/Wy 19.11.12 Pz Replaced for: Replaced by: --- KTR Kupplungstechnik GmbH D-48407 Rheine NVT-E Operating-/Assembly Instructions KTR-N Sheet: Edition: 42611 EN 12 of 27 1 4 Operation 4.6 Amendment of Basic Settings 4.6.5 Activating/Deactivating Key Lock To prevent unauthorized modifications of settings on the device, it is possible to activate a key lock. The key lock is activated if at least one digit is set > 0. While entering the data the active digit is marked with a dot. Open the parameter menu by pressing the key : Set the digit via the keys and (0 to 9) and accept by pressing the key . The active digit shifts to the right by one place. Finally accept the code by pressing the key . The device returns to the submenu. Please note: Enter 000 to deactivate the key lock. 4.6.6 Scaling of Charging Level Scaling of the display range is effected between the highest and the lowest level of the float. The display accuracy and the resolution for defining the switching outputs for the charging level are affected by this scaling, too. The factory setting of the switching point and the display is shown in illustration 5: A: Factory settings 1: Measuring range A: Types with analogue output: The factory setting provides for an ascending display with the charging level being ascending so that 0 % are displayed with the lowest possible point and 100 % with the highest possible point. These values can be modified as described below. Illustration 5 Please note protection mark ISO 16016. Drawn: Verified: 11.10.12 Pz/Wy 19.11.12 Pz Replaced for: Replaced by: --- KTR Kupplungstechnik GmbH D-48407 Rheine NVT-E Operating-/Assembly Instructions KTR-N Sheet: Edition: 42611 EN 13 of 27 1 4 Operation 4.6 Amendment of Basic Settings 4.6.7 Maximum Displayed Value of Charging Level The displayed value (upper limit of the measurement range) for the maxium charging level is defined here. Assignment of the maximum displayed value (upper limit of the measurement range) towards the maximum charging level Please note: Setting range: -999…9999 To prevent misoperation, the settings of the level outputs should be reviewed or adapted after changing. 4.6.8 Minimum Displayed Value of Charging Level The displayed value (lower limit of the measurement range) for the minimum charging level is defined here. Assignment of the maximum displayed value (upper limit of the measurement range) towards the maximum charging level Please note: Setting range: -999…9999 To prevent misoperation, the settings of the level outputs should be reviewed or adapted after changing. 4.6.9 Resetting Factory Settings (Reset) The function Reset ( ) allows to reset the factory settings. Since the limit values are reset, too, it is not absolutely necessary to review the settings for the charging level and the temperature. ! CAUTION! All modifications are lost when using the function RESET. The following menu items are available: Delivery status: NO. The current settings are kept. Please note protection mark ISO 16016. Drawn: Verified: 11.10.12 Pz/Wy 19.11.12 Pz Delivery status: Yes. The settings are reset to the standard factory settings. Replaced for: Replaced by: --- KTR Kupplungstechnik GmbH D-48407 Rheine NVT-E Operating-/Assembly Instructions KTR-N Sheet: Edition: 42611 EN 14 of 27 1 4 Operation 4.6 Amendment of Basic Settings 4.6.10 Factory Settings Definitions of the factory settings set: x/ x x/ x x. / x. x x / / x Switching point / reset point x Delay for switching/delay for resetting for switching output x Maximum and minimum measured value for output Signal characteristics of analogue output Switching characteristics of switching output x Unit for charging level/temperature Maximum / minimum charging level Assignment of switching output x towards charging level or temperature monitoring Updating rate of display Key lock Recorded switching output Delay for recording the minimum/maximum charging level Delay for recording the minimum/maximum temperature ATTENTION! With customized parameters the pre-setting performed by the customers may differ from the figures mentioned in here. Table 4: Type with 4 switching outputs Switching ouptuts / 5% / 2% / / / / / / / / % °X / / / % / / Diagnostics °X / / / / 15% / 12% / / Basic settings -I- (%) / °X / Table 5: Type with 2 switching outputs and 2 analogue outputs Switching outputs / 5% / 2% / / / / / / / Diagnostics °X / / Basic settings -I- (%) °X / % % Analogue outputs / / / / / / / / Please note protection mark ISO 16016. Drawn: Verified: 11.10.12 Pz/Wy 19.11.12 Pz Replaced for: Replaced by: --- KTR Kupplungstechnik GmbH D-48407 Rheine NVT-E Operating-/Assembly Instructions KTR-N Sheet: Edition: 42611 EN 15 of 27 1 4 Operation 4.7 Switching Outputs All switching outputs are set in the same way. Therefore, the number of the switching output is marked x. Select the switching output to be set via the menu of the corresponding measurement size ( or ). Table 6: Assignment of switching outputs (factory-provided) Switching output 1 2 3 4 Assignment with 2 switching outputs Charging level Temperature Assignment with 4 switching outputs Charging level Charging level Temperature Temperature ATTENTION! The assignment of the switching outputs as well as further basic settings referring to all switching outputs can be modified in the menu Basic settings extended functions. The submenu Extended functions allows to execute further settings for each switching output affecting, for example, the switching behaviour of the output. Testing the output is possible here, too. 4.7.1 Definition of Switching Characteristics The switching characteristics for the output are defined in the following menu: The following menu items are available: Hysteresis function Function of make contact or break contact setting the output signal when exceeding the switching point defined. If the reset point is fallen below, the output signal is deleted. Hysteresis function make contact Hysteresis function break contact Please note protection mark ISO 16016. Make contact means here that the PNP switching output is closed if the measured value is above the switching point x and is opened if the reset point x is fallen below. Break contact means here that the PNP switching output is open if the measured value is above the switching point x and is closed if the reset point x is fallen below. See explanations in the drawing below. Drawn: Verified: 11.10.12 Pz/Wy 19.11.12 Pz Replaced for: Replaced by: --- KTR Kupplungstechnik GmbH D-48407 Rheine NVT-E Operating-/Assembly Instructions KTR-N Sheet: Edition: 4 Operation 4.7 Switching Outputs 4.7.1 Definition of Switching Characteristics Window function Window function make contact Window function break contact Frequency output Frequency output Function of make contact or break contact defining a signal window. If the measured window is reached, the output signal is set and deleted once it is left. Make contact means here that the PNP switching output is closed if the measured value is within the window limits. Otherwise the switching output is open. Break contact means here that the PNP switching output is open if the measured value is within the window limits. Otherwise the switching output is closed. If the output is defined as a frequency output, a square wave signal with a frequency between 1 Hz and 100 Hz is given proportionately to the measured value. ATTENTION! To increase the slew rate of the square wave signal, we recommend to load the switching output with a 10 k resistance. ATTENTION! The switching function may have different descriptions: Illustration 6 Please note protection mark ISO 16016. Drawn: Verified: 11.10.12 Pz/Wy 19.11.12 Pz Replaced for: Replaced by: --- 42611 EN 16 of 27 1 KTR Kupplungstechnik GmbH D-48407 Rheine NVT-E Operating-/Assembly Instructions KTR-N Sheet: Edition: 42611 EN 17 of 27 1 4 Operation 4.7 Switching Outputs 4.7.2 Upper Switching Limit (Set Point) The upper switching limit for switching output OUT 1 is set in the following submenu: Switching point for OUT x Please note: The switching point must be set within the measuring range (see menu Basic settings extended functions). Setting range: [ ] …. [ ] If the function window was assigned to the switching output OUT 1, is displayed. The value set corresponds to the upper window limit. If the function frequency output was assigned to the switching output OUT 1, is displayed. The value set corresponds to the frequency 100 Hz. 4.7.3 Lower Switching Limit (Reset Point) The lower switching limit for switching output OUT 1 is set in the following submenu: Reset point for OUT 1 Please note: The reset point must be set within the measuring range. Setting range: [ ] …. [ ] If the function window was assigned to switching output OUT 1, displayed. The value set corresponds to the upper window limit. If the function frequency output was assigned to the switching output OUT 1, is displayed. The value set corresponds to the frequency 1 Hz. Please note protection mark ISO 16016. Drawn: Verified: 11.10.12 Pz/Wy 19.11.12 Pz Replaced for: Replaced by: --- is KTR Kupplungstechnik GmbH D-48407 Rheine NVT-E Operating-/Assembly Instructions KTR-N Sheet: Edition: 42611 EN 18 of 27 1 4 Operation 4.7 Switching Outputs 4.7.4 Delay for Set Point The menu Extended functions x provides further settings for the switching output x. The submenu is located on the second submenu level: The delay time for set point and reset point prevents too many false alarms with turbulent conditions. The delay for the set point is set in the following menu: Time period in seconds during which the signal must remain continuous to enable the switching output to respond. Please note: Setting range: 0 .… 100 seconds If the function window was assigned to the switching output OUT x, the value set corresponds to the delay for set point detecting when the measurement window is actually reached. If the function frequency output was assigned to the switching output OUT x, this value has no effect. 4.7.5 Delay for Reset Point The delay for reset point is set in the following menu: Delay for reset signal for OUT x Time periods in seconds during which the signal must remain continuous to enable the switching output to respond. Please note: Setting range: 0 .… 100 seconds If the function window was assigned to the switching output OUT 1, the value set corresponds to the delay for reset point detecting when the measurement window is actually left. If the function frequency output was assigned to the switching output OUT 1, this value has no effect. Please note protection mark ISO 16016. Drawn: Verified: 11.10.12 Pz/Wy 19.11.12 Pz Replaced for: Replaced by: --- KTR Kupplungstechnik GmbH D-48407 Rheine NVT-E Operating-/Assembly Instructions KTR-N Sheet: Edition: 42611 EN 19 of 27 1 4 Operation 4.7 Switching Outputs 4.7.6 Testing the Switching Output Testing the switching output can be started in the following menu: Testing options for the switching output Options for setting from to / Normal operation of switching output Switching off the switching output permanently Options for setting from Normal operation as a frequency output / / : Switching on the switching output permanently to Output frequency 1 Hz Output frequency 100 Hz ATTENTION! Having completed the tests, please make absolutely sure to set the function to normal operation . 4.7.7 Changing Display Function of Status LED The switching status of the output is indicated by the LEDs in the display. The assignment of LED to the switching output is shown in the table below: Table 7: Numbering of LED Switching output x 1 2 3 4 Assignment with 2 switching outputs LED 1 – yellow LED 2 – red Assignment with 4 switching outputs LED 1 – yellow LED 2 – red LED 3 – yellow LED 4 – red In the factory settings the LED indicates the physical condition of the PNP switching output (switching output closed – LED is illuminated). In some cases the logical function of the display is to act differently from the physical signal on the switching output. Therefore, the display in this menu item can also be reverted (switching output opened – LED is illuminated). Example based on temperature: Two switching outputs are available for temperature which are set as follows: Upper switching contact: maximum contact, ascending make contact. The LED is illuminated when the maximum value of temperature is exceeded and the temperature is beyond the requested range. Thus, the status indicated is “error” if the LED is illuminated. Lower switching contact: minimum contact, ascending break contact. The LED is illuminated with the factory settings when the minimum value of temperature is exceeded. In this case the LED would be illuminated if the status is in order. Please note protection mark ISO 16016. Drawn: Verified: 11.10.12 Pz/Wy 19.11.12 Pz Replaced for: Replaced by: --- KTR Kupplungstechnik GmbH D-48407 Rheine NVT-E Operating-/Assembly Instructions KTR-N Sheet: Edition: 42611 EN 20 of 27 1 4 Operation 4.7 Switching Outputs 4.7.7 Changing Display Function of Status LED The table shows an example with factory settings and with inverted status function for LED3. The switching points are defined as follows: = 70 °C, = 80 °C, = 65 °C = 75 °C Table 8: Status function LED3 inverted Factory settings A LED3 on LED3 off B LED4 and LED3 on only LED4 on C LED3 on LED3 off D LED3 off LED3 on Situation Status Temperature rising to > 70 °C PNP switching output 3 is closed OK Temperature rising to > 80 °C PNP switching output 4 is closed Error Temperature dropping to < 75 °C PNP switching output 4 is opened OK Temperature dropping to < 65 °C PNP switching output 3 is opened Error Here you can invert the status function of LED for a contact: the LED is illuminated if the contact is opened, thus falls below the minimum temperature, and when the LED is illuminated the status „error“ is indicated. Especially the recording of incidents depends on the illumination of LED (see chapter 4.9 Diagnostics, ). The following menu items are available: LED = output; the LED is illuminated if the PNP switching output is closed. LED = -output; the LED is illuminated if the PNP output is opened. Please note: The recording of incidents specifically depends on the illumination of the LED (see chapter 4.9 Diagnosis, ). Please note protection mark ISO 16016. Drawn: Verified: 11.10.12 Pz/Wy 19.11.12 Pz Replaced for: Replaced by: --- KTR Kupplungstechnik GmbH D-48407 Rheine NVT-E Operating-/Assembly Instructions KTR-N Sheet: Edition: 42611 EN 21 of 27 1 4 Operation 4.8 Analogue Outputs 4.8.1 Assignment of Upper Limit The assignment is defined as to which charging level is necessary to display the maximum analogue signal. The setting is made in the following menu: Please note: Setting range: [ ] …. [ ] The output range set must not be smaller than 10% of the measurement range: ≥ 10% * ( ). If the range selected is too small, the analogue output value may have steps. 4.8.2 Assignment of Lower Limit The assignment is defined as to which charging level is necessary to display the minimum analogue signal. The setting is made in the following menu: Please note: Setting range: [ ] …. [ ] The output range set must not be smaller than 10% of the measurement range: ≥ 10% * ( ). If the range selected is too small, the analogue output value may have steps. 4.8.3 Defining the Type of Signal The analogue output can be defined as voltage or current output with different value ranges. The setting is made in the following menu: The following menu items are available: 4 mA to 20 mA Please note protection mark ISO 16016. Drawn: Verified: 2 V to 10 V 11.10.12 Pz/Wy 19.11.12 Pz 0 V to 10 V Replaced for: Replaced by: 0 V to 5 V --- KTR Kupplungstechnik GmbH D-48407 Rheine NVT-E Operating-/Assembly Instructions KTR-N Sheet: Edition: 42611 EN 22 of 27 1 4 Operation 4.8 Analogue Outputs 4.8.4 Testing the Analogue Output The analogue output can be tested, too. The highest, the average and the smallest analogue value can be displayed one after another. The setting is made in the following menu: The following menu items are available: Normal operation Output of highest analogue value Output of average analogue value Output of lowest analogue value ATTENTION! On termination of the test please make absolutely sure to set the function to normal operation . 4.9 Diagnostics The device is in a position to record the incidents for a switching output. A result is defined as an illumination of the LED. Accordingly, the recording of the switching processes depends on the setting of the switching function of LEDs. The settings and the evaluation can be performed as follows: ATTENTION! It is only possible to record one switching output. The switching output to be recorded is set in the menu item switching output Log Alarm . Press the key to open the main menu. Select the menu item via the keys and . Please note: This menu provides various diagnostics values and recordings for monitoring of charging level and temperature. Open the menu via the key . Now you are in a position to amend or retrieve the settings for diagnostics. Please note protection mark ISO 16016. Drawn: Verified: 11.10.12 Pz/Wy 19.11.12 Pz Replaced for: Replaced by: --- KTR Kupplungstechnik GmbH D-48407 Rheine NVT-E Operating-/Assembly Instructions KTR-N Sheet: Edition: 42611 EN 23 of 27 1 4 Operation 4.9 Diagnostics 4.9.1 Opening the Journal The last 6 incidents recorded of the switching output can be retrieved or deleted here. The journal entries are indicated in the following way: Example: , Key , Key , , Key , , Key , *, Key , *, Key , , Key ; = delete Latest incident took place x hours ago (h) / days ago (d) Incidents 2 to 5 took place x hours/days ago Latest incident took place x hours/days ago Delete ( ). * not yet recorded, only 4 incidents have taken place The display toggles between the index of recording x and the time when it occurred, e. g. for the latest incident 1.4 hours ago. Accepting the display the submenu. via the key deletes the journal and returns to Please note: If no incident was recorded, the display toggles between x and The data stored are overwritten after 6 months. Please note protection mark ISO 16016. Drawn: Verified: 11.10.12 Pz/Wy 19.11.12 Pz Replaced for: Replaced by: --- . KTR Kupplungstechnik GmbH D-48407 Rheine KTR-N Sheet: Edition: NVT-E Operating-/Assembly Instructions 42611 EN 24 of 27 1 4 Operation 4.9 Diagnostics 4.9.2 Maximum/Minimum Charging Level In this menu the maximum and minimum charging level saved is displayed or deleted. Diagnostic di A ► Diagnostics menu Max/Min Level o)MM Max-/Min memory ► Parameter ____ ___;_ - - - - The values are displayed as follows: Example: , Key , Key , , Key , , Key , , Key ; = delete Maximum value of charging level, reached x hours/days ago, minimum value of charging level, reached x hours/days ago, delete function. Accepting the display the submenu. Menu order: Max. value, time Min. value, time delete via the key deletes the journal and returns to Please note: The data saved are overwritten after six months. 4.9.3 Maximum/Minimum Temperature In this menu the maximum and minimum temperature saved is displayed or deleted. The values are displayed as follows: Example: , Key , Key , , Key , , Key , , Key ; = delete Maximum value of temperature, reached x hours/days ago, minimum value of temperature, reached x hours/days ago, delete function. Accepting the display the submenu. Menu order: Max. value, time Min. value, time delete Please note protection mark ISO 16016. via the key deletes the journal and returns to Please note: The data saved are overwritten after 6 months. Drawn: Verified: 11.10.12 Pz/Wy 19.11.12 Pz Replaced for: Replaced by: --- KTR Kupplungstechnik GmbH D-48407 Rheine NVT-E Operating-/Assembly Instructions KTR-N Sheet: Edition: 42611 EN 25 of 27 1 4 Operation 4.9 Diagnostics 4.9.4 Assigning the Switching Output for Recording In this menu the switching output for recording is selected. Only one switching output can be recorded. Diagnostic di A ► Diagnostics menu Set Jornal Out SJ)ou Set recorded output ► Parameter out _ Out 1 - Out _ Please note: Range: to The figures are saved from the volatile memory to the nonvolatile memory about every three hours. x The data saved are overwritten after 6 months. 4.9.5 Delay for Min./Max. Saving (Charging Level) To record reliable values in case of fluctuating charging level, a delay period to save the minimum and maximum charging level can be set. Here the period in seconds is set during which the signal must remain continuous before the charging level is recorded. Diagnostic di A ► Diagnostics menu Delay MM do)MM ► Delay storing Min/Max Parameter ___ 0 - 100 Please note: Open the value journal by pressing the key . Setting range: 0 .… 100 seconds Set the value via the keys and and accept via the key (e. g. 5 (seconds)). The device returns to the submenu. 4.9.6 Delay for Min./Max. Saving (Temperature) To record reliable values in case of fluctuating temperature, a delay period to save the minimum and maximum temperature can be set. Here the period in seconds is set during which the signal must remain continuous before the temperature is recorded. Diagnostic di A Diagnostics menu ► Delay MM dt )MM Delay storing Min/Max ► Parameter ___ 0 - 100 Please note: Open the value journal by pressing the key . Setting range: 0 .… 100 seconds Please note protection mark ISO 16016. Set the value via the keys and and accept via the key (e. g. 5 (seconds)). The device returns to the submenu. Drawn: Verified: 11.10.12 Pz/Wy 19.11.12 Pz Replaced for: Replaced by: --- KTR Kupplungstechnik GmbH D-48407 Rheine NVT-E Operating-/Assembly Instructions KTR-N Sheet: Edition: 42611 EN 26 of 27 1 5 Spares Inventory, Customer Service Addresses Contact addresses of the KTR partners for spare parts and orders can be obtained from the KTR homepage under www.ktr.com. ATTENTION! KTR does not assume any liabilities or guarantees regarding the use of spare parts and accessories which are not provided by KTR and for the damages resulting herefrom. 6 Disposal In respect of environmental protection we would ask you to dispose of the products on termination of their service life in accordance with the effective legal regulations and standards, respectively. Gaskets Gaskets can be disposed of by residual waste. Electric compontens Electric components have to be treated as electric waste. Hydraulic oil Hydraulic oils have to be collected in suitable tanks and disposed of by a waste disposal company. 7 Maintenance and Service NVT-E is a maintenance-free level switch and level with temperature switch. We recommend the NVT-E should be subject to a visual and functional inspection at least once a year. ATTENTION! If you find out any irregularities, please consult with KTR Kupplungstechnik. Please note protection mark ISO 16016. Drawn: Verified: 11.10.12 Pz/Wy 19.11.12 Pz Replaced for: Replaced by: --- KTR Kupplungstechnik GmbH D-48407 Rheine NVT-E Operating-/Assembly Instructions KTR-N Sheet: Edition: 42611 EN 27 of 27 1 7 Maintenance and Service 7.1 Breakdowns, Causes and Elimination The breakdowns mentioned can only be indications for troubleshooting. For troubleshooting generally the adjacent components have to be included. In case of breakdown all outputs are set dead-voltage. The four LEDs are illuminated. The failures are saved in the device until it is switched off. Breakdowns Causes No supply voltage (no display) ↔ Elimination 1) inspect cable and replace, if necessary Error indication in the display toggles between, e. g. Err- and E--Error 01 Error 02 Error 04 Error 08 Error 16 Error 32 Please note protection mark ISO 16016. Ambient temperature too low Ambient temperature too high Pt 100 defective (short circuit) Pt 100 defective (cable break) Conductor chain defective (short circuit) Conductor chain defective (feed cable open) Drawn: Verified: 11.10.12 Pz/Wy 19.11.12 Pz 1) observe limit values 1) observe limit values 1) 2) 1) 2) 1) 2) 1) 2) Replace feed cable Pt 100 Send device for repair Replace feed cable Pt 100 Send device for repair Replace feed cable Send device for repair Replace feed cable Send device for repair Replaced for: Replaced by: --- ">
/

Download
Just a friendly reminder. You can view the document right here. But most importantly, our AI has already read it. It can explain complex things in simple terms, answer your questions in any language, and help you quickly navigate even the longest or most compilcated documents.
Advertisement