URBACO CC6U200PR, CC6U200PRS, LUXOR BPLUXE60/G/R, BPLUXE80/G/R, PLUXF60/G/R, BPLUXF80/G/R, BPLUXG60/G/R, BPLUXG80/G/R, LUXOR COPURA-LUX, COKCHGT-LUX, BOEVP-LUX, BOEVB-LUX, COVF-LUX, KITBEA-LUX Installation, Use & Maintenance
The LUXOR CC6U200PR, LUXOR CC6U200PRS Technical Centre is a pneumatic device that controls and operates LUXOR BPLUXE60/G/R, LUXOR BPLUXE80/G/R, LUXOR PLUXF60/G/R, LUXOR BPLUXF80/G/R, LUXOR BPLUXG60/G/R, LUXOR BPLUXG80/G/R bollards. It can be installed in various configurations to control up to 3 access ways, and can be equipped with a range of optional accessories including cooling fans, a heating unit, and an automatic drainage system with timer. The Technical Centre is designed for use in public and private spaces, and can be used to control access to parking lots, loading docks, and other areas.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
Luxor Technical Centre Installation, Use & Maintenance English EN Contents 1- Legend of symbols..........................................................................................................................................Pag.3 2-Conditions of use..............................................................................................................................................Pag.3 2.1-Intended use......................................................................................................................................Pag.3 2.2-Limits to use.....................................................................................................................................Pag.3 4-Descriptions............................................................................................................................................Pag.3 4.1-Technical centre - technical features.....................................................................................................Pag.3 4.2-Technical centre: components and dimensions ...............................................................................Pag.4 4.3-(Technical centre) Pneumatic performances.................................................................................Pag.5 5-Control panel....................................................................................................................................................Pag.6 5.1-Summary table of accessories’ power demands.............................................................................Pag.7 5.2-Electrical connections......................................................................................................................Pag.8 5.3-Release/discharge the system from/inside the centre..................................................................Pag.8 6-Technical centre installation...........................................................................................................................Pag.10 6.1-Preliminary checks..........................................................................................................................Pag.10 6.2-Fastening to the floor with reinforcement (optional)...................................................................Pag.11 7-Connecting additional devices.....................................................................................................................Pag.12 Italiano IT 7.1-Cooling fans (optional)...................................................................................................................Pag.12 7.2-Heating unit (optional) ...................................................................................................................Pag.12 7.3-Mounting instructions for automatic purge with timer (optional)...................................................Pag.13 8-Safety instructions ........................................................................................................................................Pag.14 Italiano IT 9-Maintenance.........................................................................................................................................Pag.14 9.1- Periodic maintenance....................................................................................................................Pag.14 9.2-Trouble shooting.............................................................................................................................Pag.14 IT 10-Phasing out and disposal...........................................................................................................................Pag.17 Italiano 9.3-Registro interventi..........................................................................................................................Pag.15 11-Declaration of conformity.............................................................................................................................Pag.17 Pag. 2 - Manual code: 119G914 119G9141 ver. 1. 1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users. English EN 3-Reference Standards.......................................................................................................................................Pag.3 “IMPORTANT INSTALLATION, SAFETY INSTRUCTIONS” “CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY” “THIS MANUAL IS ONLY FOR PROFESSIONAL OR QUALIFIED INSTALLERS” 1 Legend of symbols This symbol tells you to read the section with particular care. This symbol tells you that the sections concern safety issues. EN This symbol tells you what to say to the end-users. English 2.1 Intended use This product can be used only for purposes indicated in this manual The use of this product for purposes other than those described above and installation executed in a manner other than as instructed in this technical manual are prohibited. Urbaco has no responsibility for any improper use of the system 2.2 Limits to use Do not allow children to play or loiter within the movement area of the bollard. Keep transmitters and any other command device out the reach of children, to prevent operator from being activated by accident. 3 Reference Standards This product complies with the following standards: see chapter 11 - Conformity declaration - pag. 17. 4 Descriptions 1500 W 100 mA Protection rating IP 44-54 Acoustic pression 69-70 Db Weight 60 kg Cabinet material Laquered 15/10 sheet metal Operating temperature -10° +55° Duty cycle 40% Italiano IT Weight Draw when idle Italiano 230 V - 50/60Hz IT (Electric) power supply IT 4.1 Technical centre - technical features Italiano 119G9141 ver. 1. 1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users. Pag. 3 - Manual code: 119G914 2 Intended use and limits to use 4.2 (Technical centre) Description: Components and dimensions 5 4 3 2 10 6 9 1 5 7 8 IT 1 Italiano a 2 Control panel 3 Magnetic loops (optional) 4 Hot/Cold thermostats (optional) 5 Cooling fans (optional) 6 Heating unit (optional) 7 Automatic purge (optional with timer) 8 Floor mounting basement (optional) 9 Air joints for bollards (Ø 10) 10 Air circuit discharge 11 Pressure regulator (manometer) c Italiano IT Italiano IT b Compressor group/unit d e a 300 b 806 c 606 d 100 e 270 Pag. 4 - Manual code: 119G914 119G9141 ver. 1. 1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users. English EN 11 4.3 (Technical centre) Pneumatic performances The following performances have been recorded with a 50 m long conduit of 10 mm diameter Ø 270 Ø 320 h 600 8 7 6 h 800 6 5 4 EN Ø 200 English Max no. of bollards Max no. of manoeuvres per hour No. of bollards Ø 200 Ø 270 Ø 320 h 600 h 800 h 600 h 800 h 600 h 800 1 100 70 100 70 100 70 2 45 35 45 35 45 35 3 30 24 30 24 30 24 4 24 18 24 18 24 18 5 18 14 18 14 18 6 16 12 16 7 14 8 12 16 14 Reliable values if T=25°C and compressor duty cycle of up to 40% The no. of manoeuvres should be evenly distributed over time The conduit length has influence on the max no. of manoeuvres per hour For intensive use manoeuvres the use the aeration kit is required h 800 h 600 h 800 h 600 h 800 1 35 50 35 50 35 50 2 80 104 80 104 80 104 Ø 270 Ø 320 3 120 150 120 150 120 150 4 150 190 150 190 150 190 5 190 260 190 260 190 6 225 280 225 7 250 8 300 IT h 600 Ø 200 Italiano No. of bollards Italiano IT Minimal interval between two subsequent manoeuvres (s) 225 IT 250 Italiano 119G9141 ver. 1. 1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users. Pag. 5 - Manual code: 119G914 Max no. of Luxor bollards operated simultaneously by a single technical centre 5 Card Trimmer for the automatic closing time adjustment ON 1 2 3 4 Fuses 5 ON L1T L2T 24 15 0 1 2 3 4 5 English EN Buttons for radio programming Compressor 1 2 3 4 5 6.3 Connector for radio cards L N Table of fuses Additional control boards for managing up to 3 access ways Fuse for accessories 5A Fuse for main line 630 mA Fuse for control board 1A Fuse for compressor 6.3 A -T DIP n° 1 ON OFF Automatic closing – enabled Automatic closing - disabled Only-opening enabled Only-opening disabled 3” Pre-flashing enabled Pre-flashing disabled DIP n° 2 IT DIP n° 3 DIP n° 4 Italiano Programming (see table below) DIP n° 5 Switch Italiano IT Italiano IT N°4 Button N°5 CH1 CH2 Led After 5” Option ON ON ON It enables the bistable solenoid valve ON ON OFF It enables the monostable solenoid valve ON ON ON It enables the acoustic signaller and the flashing of the red traffic light ON ON OFF It disables the acoustic signaller ON ON ON Green traffic light enabled ON ON OFF Yellow traffic light enabled ON ON ON “Presence” function is enabled (it is possible to retract the bollard only when the loop detects the mass) ON ON OFF “Presence” function is disabled Put the n°4 and n° 5 dip switch into ON position, then press the CH1 or CH2 buttons. The led starts flashing. After 5”, if the led is still flashing, it means that the option is enabled; if it is not, then the option is disabled. Pag. 6 - Manual code: 119G914 119G9141 ver. 1. 1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users. ON 5.1 Summary table of 24 V accessories’ power demand, expressed in W U200 control panel to control 1 access way Bistable solenoid valve * 3 Duty cycle 6 Traffic light Magnetic loop Total power (W), if with bistable solenoid valve 48 8 24 6 18 8 25 11 2.5 Flashing light 1 2 3 24 25 22 7.5 102.5 25 22 7.5 120.5 Total (W) U200 control panel + U201 board to control 2 separated access ways Bistable solenoid valve * 8 3 3 Duty cycle 6 Traffic light ** Magnetic loop Total power (W), if with bistable solenoid valve 48 8 24 6 18 8 25 11 2.5 Flashing light** Total power (W), if with monostable solenoid valve 2 4 6 24 50 50 44 44 15 131 Total (W) 15 125 113 117 Duty cycle 3 25 11 2.5 Flashing light *** Traffic light *** Magnetic loop Total (W) * Total power (W), if with monostable solenoid valve 6 Total power (W), if with bistable solenoid valve 48 8 24 6 IT Bistable solenoid valve * 8 3 Monostable solenoid valve Max no. of connectable accessories and bollards 18 8 3 6 9 Italiano Type of accessory Single accessory power (W) IT U200 control panel + two U201 boards to control 3 separated access ways Italiano Monostable solenoid valve Max no. of connectable accessories and bollards 24 75 22.5 163.5 75 66 22.5 154.5 22.5 145.5 66 22.5 136.5 The bistable solenoid valves are used in such systems, where the bollard should remain in the higher position even when voltage is cut off ** If you use the flashing light you cannot use the traffic light *** According to this configuration, the flashing lights or the traffic lights should be externally supplied. IT Type of accessory Single accessory power (W) Italiano 119G9141 ver. 1. 1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users. Pag. 7 - Manual code: 119G914 8 3 Total power (W), if with monostable solenoid valve EN Monostable solenoid valve Max no. of connectable accessories and bollards English Type of accessory Single accessory power (W) 5.2 Electrical connections L Compressor N Line voltage 230V - 50/60Hz N Magnetic sensor/photocells max power supply (see tab. in chap. 5.1) N L N L N Flashing light output voltage 24V 25W Red traffic light and illuminated ring (see tab. in chap. 5.1) Italiano IT L Yellow traffic light (see tab. in chap. 5.1) N N Solenoid valve for the upward movement max voltage 24V AC (see tab. in chap. 5.1) Italiano L IT Italiano IT L Solenoid valve for the downward movement 24V AC (optional) or downward command for the bistable valve Pag. 8 - Manual code: 119G914 119G9141 ver. 1. 1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users. English EN L Compressor L N Closing button N.C. STOP button N Step by step English SMA N.C. contact Compressor surveillance Purge opening 1 Purge closing 2 Italiano To discharge air from the system and consequently move down the bollards, you can open the tap nearby the pressure switch (we recommend you to do it when the compressor is shut down, in order to avoid that it starts automatically to compensate the pressure fall).To put the system into operation again, close the air discharge as shown in fig. 2 (and turn on the compressor, if you had shut it down). IT 5.3 Release/discharge the system from/inside the centre IT N Italiano L Endstop - closing IT N Endstop - opening Italiano L 119G9141 ver. 1. 1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users. Pag. 9 - Manual code: 119G914 EN L 6 Technical centre installation -Check that no conduits or other obstacles shall prevent from excavating and installating operations. -Check the soil consistence and its loading capacity. -On the power supply line provide an omnipolar disconnecting device with an opening distance between contacts equal to or larger than 3 mm. We recommend you to use a 10 A omnipolar disconnecting device. -Remove any obstacle that can prevent the bollard form a normal operating mode. -The magnetic loops positioning has influence on the access correct functioning. In fact, we recommend you to chose first the loops position, then the bollards one and then that for the technical centre. -Position the technical centre in a way to protect it from accidental hurting. -Provide for a conduit to pass connections through it. -When necessary, you need to install optical and sound signalization to minimize dangerous situations. -Air flexibles max length must not exceed 100 m -Max distance of the cable connecting the feeder and the magnetic loop shall not exceed 50 m. Max depth for magnetic loops: 150 mm EXIT Bollards SAFETY LOOP Pit PRESENCE AND SAFETY LOOP Sheaths Sheath Min. distance between conductors Italiano IT Italiano IT Italiano IT LOOPS IN EXIT ENTRANCE Table of connections Air piping Rilsan PA11 - DIN 74324 Ø 10x8 Electrical connections between technical centre and bollards FG7(O) R0.6/1kW 10x1.5 Links between SMA and loop Min. 20 windings per meter Ø 1x1.5 Connection to the traffic light FG7(O) R0.6/1kW 3x1.5 Control unit Pag. 10 - Manual code: 119G914 119G9141 ver. 1. 1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users. English EN 6.1 Preliminary checks 6.2 Technical centre fastening with reinforcement (optional – COREH02-LUX code) 150 70 120 Provided with: • M8 cage nuts – 4 pieces • washers – 4 pieces D8x24 • securing screws – 4 pieces M8x16 UNI 5739 • securing screws for inspection flange EN Conduits connecting area Flange for inspection on both sides 2 3- and finally, as shown in picture n°2, fasten the technical centre to the reinforcement using the supplied screws Italiano IT Italiano 2- then anchor the reinforcement to the floor IT 1- hook the M8 cage nuts as shown in picture n°1 IT Check that the fastening point is resistant and protected against hurting. The fastening should be carried out with suitable screws, plugs, etc. (not included), depending on the surface typology. 1 Italiano 119G9141 ver. 1. 1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users. Pag. 11 - Manual code: 119G914 60 4 square holes for the M8 locked nuts English Dimensions and holes spans 7 Connection of additional devices 7.1 Cooling fans (optional – COVF-LUX code) 1) Take off the grids that shall support the fans. 1 2) On the grids mount the motors (please check to put one for intake and another in discharge), by using the supplied cables. a b 2 OUT c OUT IN IN d Connection scheme a Upper cover b Dustproof filter c Carter for motor fastening Electrical connections, including earthing e Fan f Sealing 7.2 Heating unit (optional – COKCHGT-LUX code) 2 Following the scheme in pict. n°1, connect this heating unit to the thermostat by using the supplied cables. Then put both of them into the technical centre (see pict. 2) 1 IT Thermostat Italiano f d Italiano IT Italiano IT LN e Heating unit Connecting scheme L N Pag. 12 - Manual code: 119G914 119G9141 ver. 1. 1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users. English EN NOTE: face the electrical connections (d – see pict. n°2) toward the inside of the technical centre. The connecting cables should not come into contact with heated zones (i.e. heating unit, compressor head). 7.3 Assembly of the automatic drainage with timer (optional - COPURA-LUX code) 1 English Unscrew and take off tap and joint as shown in pict. 2. If present, please take off the sound-absorbing plug, as shown in the pict.1, otherwise go to the second step, shown in pict. 2. Connect the condensate release with the timer to the previously connected . Use a seal, as shown in pict. 4. 6 IT Italiano 5 IT Italiano Using a 7 mm hexagonal wrench, screw the extension provided in the automatic drainage kit, as shown in pict. 3. 4 IT 3 Insert in the rapid joint a Ø 7 conduit to enable the release outside of the centre (pict. 5). To feed the automatic drainage with timer, link the two phases to the terminal board and connect the earthing as shown in pict. 6. Italiano 119G9141 ver. 1. 1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users. Pag. 13 - Manual code: 119G914 EN 2 8 Safety instructions Important safety instructions 9 Maintenance 9.1 Periodic maintenance -Before performing any maintenance procedures, cut off the main power, to prevent possible accidents due to gate movement. Check point Check and maintenance 1° 2° 3° 4° 5° 6° 7° 8° 9° 10° 11° 12° month month month month month month month month month month month month 1 Compressor functioning 2 Cleaning of the centre x x 3 Endstops x x 4 Solenoid valve x x 5 No Air leak x x 6 Cooling fans x x x x 7 Heating unit x x 8 Automatic drainage functioning x x 9 Metal detecting loops x x Italiano IT Italiano IT Italiano IT 9.2 Problems resolution MALFUNCTIONS POSSIBLE CAUSES REMEDIES The solenoid valve is sup- The air doesn’t come to the solenoid valve. plied (check it by using a voltmeter) but the bollards The flux regulator is closed doesn’t move upwards. Solenoid valve winding has burnt out Check the compressor and the air circuit. The bollard move upwards Presence of foreign bodies on the guide. irregularly. Air pressure is not sufficient. Check the guides status. Pulire. The compressor works too frequently. Air leak. Check the flexible air tube and the couplings (if needed use foam spray to detect leaks). Air leak at the solenoid valve release. Purge the circuit and clean (or replace) the electrovalve (foreign objects in the air circuit). The pressure is too high. Check that pressure switch ( 6 – 8 bar when working). Open the flux regulator. Change the winding. Clean and verify the manometer regular pressure (6-8 bars) Pag. 14 - Manual code: 119G914 119G9141 ver. 1. 1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users. English EN This product must only be employed for its originally intended use. Any other use is wrong and potentially dangerous. The manufacturer cannot be held liable for any damages resulting from wrongful, erroneous or negligent uses. Avoid working close to the hinges or other moving mechanical parts. Stay out of the opening/closing arc when operator is in movement. Do not exercise force against the motion of the operator as this could result in potentially dangerous situations. Do not allow children to play or loiter within the opening/closing arc of the operator. Keep transmitters and any other command device out the reach of children, to prevent operator from being activated by accident. In the event of anomalous behaviour, stop using the operator immediately. Provide for adequate safety systems such as magnetic loops, traffic lights or any device that shall prevent dangerous situations 1 Cover fastening 2 Slide ring 3 Endstop sensors 4 Solenoid valve 5 No air leak 6 Air discharge efficiency 7 Cover positioning 8 Illuminated ring 9 Magnetic loops Installer stamp YES NO Other actions ________________________________________ ________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ EN Check and maintenance English Check point Date of intervention Operator’s full name Technician signature Client signature Check point Check and maintenance 1 Cover fastening 2 Slide ring 3 Endstop sensors 4 Solenoid valve 5 No air leak 6 Air discharge efficiency 7 Cover positioning 8 Illuminated ring 9 Magnetic loops Installer stamp YES NO Other actions ________________________________________ ________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ Date of intervention Operator’s full name IT Technician signature 2 Slide ring 3 Endstop sensors 4 Solenoid valve 5 No air leak 6 Air discharge efficiency 7 Cover positioning 8 Illuminated ring 9 Magnetic loops Installer stamp YES Date of intervention Operator’s full name Technician signature Client signature NO Other actions ________________________________________ ________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ IT Cover fastening Italiano Check and maintenance 1 IT Check point Italiano Client signature Italiano 119G9141 ver. 1. 1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users. Pag. 15 - Manual code: 119G914 9.3 Records of intervention Check and maintenance 1 Cover fastening 2 Slide ring 3 Endstop sensors 4 Solenoid valve 5 No air leak 6 Air discharge efficiency 7 Cover positioning 8 Illuminated ring 9 Magnetic loops Installer stamp YES NO Other actions ________________________________________ ________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ Date of intervention Technician signature Client signature Check point Check and maintenance 1 Cover fastening 2 Slide ring 3 Endstop sensors 4 Solenoid valve 5 No air leak 6 Air discharge efficiency 7 Cover positioning 8 Illuminated ring 9 Magnetic loops Installer stamp YES NO Other actions ________________________________________ ________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ Date of intervention Operator’s full name Technician signature Italiano IT Italiano IT Italiano IT Client signature Check point Check and maintenance 1 Cover fastening 2 Slide ring 3 Endstop sensors 4 Solenoid valve 5 No air leak 6 Air discharge efficiency 7 Cover positioning 8 Illuminated ring 9 Magnetic loops Installer stamp YES Date of intervention Operator’s full name Technician signature Client signature NO Other actions ________________________________________ ________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ Pag. 16 - Manual code: 119G914 119G9141 ver. 1. 1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users. Operator’s full name English EN Check point Check and maintenance 1 Cover fastening 2 Slide ring 3 Endstop sensors 4 Solenoid valve 5 No air leak 6 Air discharge efficiency 7 Cover positioning 8 Illuminated ring 9 Magnetic loops Installer stamp YES NO Other actions ________________________________________ ________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ EN Check point Date of intervention English Technician signature Client signature 10 Phasing out and disposal Italiano PRODUCT DISPOSAL Our products are made of different types of materials. Most of these (i.e. aluminium, plastic, iron, electrical cables) are to be disposed of as solid urban waste. These can be recycled through separate waste collection and disposal at authorised facilities. Other components (i.e. electronic cards, remote control batteries, etc.) may contain hazardous materials. Thus, they must be treated and hand over to special firms authorised to properly dispose of them. Before acting, always check the specific, current legislation in your location. DO NOT DISPOSE OF IN THE ENVIRONMENT ! IT We kindly ask you to also safeguard the envirnoment, because we at URBACO considere it to be one of the fundamental elements of development of its market and operational strategies. You can do this by simply following simple disposing instructions : DISPOSING OF THE PACKAGING The components of the packaging (i.e. cardboard, plastic, etc.) are solid urban waste and can be disposed of without problems, just throw them out in the proper, correspoding recycling bins. The components of the packaging (i.e. cardboard, plastic, etc.) are solid urban waste and can be disposed of without problems, just throw them out in the proper, correspoding recycling bins. DO NOT DISPOSE OF IN THE ENVIRONMENT ! 11 Declaration of conformity IT MANUFACTURER’S DECLARATION Declares under its own responsibility that the equipments listed below: LUXOR AUTOMATIC RETRACTABLE BOLLARDS BPLUXE60/G/R, BPLUXE80/G/R, PLUXF60/G/R, BPLUXF80/G/R, BPLUXG60/G/R, BPLUXG80/G/R, LUXOR TECHNICAL CENTERS CC6U200PR, CC6U200PRS, LUXOR COMPLEMENTARY ACCESSORIES COPURA-LUX, COKCHGT-LUX, BOEVP-LUX, BOEVB-LUX, COVF-LUX, KITBEA-LUX, --- DIRECTIVES --98/37/CE - 98/79/CE 2004/108/CE 2006/95/CE 87/404/CEE 97/37/CE MACHINERY DIRECTIVE ELECTROMAGNETIC C OMPATIBILITY DIRECTIVE L OW VOLTAGE DIRECTIVE SIMPLE PRESSURE VESSELS DIRECTIVE PRESSURE EQUIPMENT DIRECTIVE --- STANDARDS --EN 60204-1 EN 61000-6-2 EN 11201 EN 1050 EN 61000-6-3 EN 1012-1 EN 60529 NF P 98-310 EN 60068-2 EN 3744 IMPORTANT WARNING! This statement is legally binding only if the speciļ¬cations in the supplied instruction manual have been properly followed. Do not use the equipment speciļ¬ ed here above, before completing the full installationIn full compliance with the Machinery Directive 98/37/EC. comply with the National Law related to the following European Directives and to the applicable parts of the following Standards. the Chairman Andrea Menuzzo IT URBACO S.A. Z.A. du Couquiou 84320 ENTRAIGUES FRANCE Italiano Pursuant to annex II A of the Machinery Directive 98/37/EC Italiano 119G9141 ver. 1. 1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users. Pag. 17 - Manual code: 119G914 Operator’s full name English - Manual code: 119G9141 ver. 1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO s.a. to notify users. URBACO SA ZA du Couquiou 84320 ENTRAIGUES -FRANCE www.urbaco.com
advertisement
Key Features
- Pneumatic control system
- Optional accessories
- Up to 3 access way control
- Bollard operation and control
- Public and private space application
- Parking lot, loading docks and other areas control