The LUXOR CC6U200PR, LUXOR CC6U200PRS Technical Centre is a pneumatic device that controls and operates LUXOR BPLUXE60/G/R, LUXOR BPLUXE80/G/R, LUXOR PLUXF60/G/R, LUXOR BPLUXF80/G/R, LUXOR BPLUXG60/G/R, LUXOR BPLUXG80/G/R bollards. It can be installed in various configurations to control up to 3 access ways, and can be equipped with a range of optional accessories including cooling fans, a heating unit, and an automatic drainage system with timer. The Technical Centre is designed for use in public and private spaces, and can be used to control access to parking lots, loading docks, and other areas.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

URBACO LUXOR Bollard Installation, Use & Maintenance Manual | Manualzz
Luxor
Technical Centre
Installation, Use & Maintenance
English
EN
Contents
1- Legend of symbols..........................................................................................................................................Pag.3
2-Conditions of use..............................................................................................................................................Pag.3
2.1-Intended use......................................................................................................................................Pag.3
2.2-Limits to use.....................................................................................................................................Pag.3
4-Descriptions............................................................................................................................................Pag.3
4.1-Technical centre - technical features.....................................................................................................Pag.3
4.2-Technical centre: components and dimensions ...............................................................................Pag.4
4.3-(Technical centre) Pneumatic performances.................................................................................Pag.5
5-Control panel....................................................................................................................................................Pag.6
5.1-Summary table of accessories’ power demands.............................................................................Pag.7
5.2-Electrical connections......................................................................................................................Pag.8
5.3-Release/discharge the system from/inside the centre..................................................................Pag.8
6-Technical centre installation...........................................................................................................................Pag.10
6.1-Preliminary checks..........................................................................................................................Pag.10
6.2-Fastening to the floor with reinforcement (optional)...................................................................Pag.11
7-Connecting additional devices.....................................................................................................................Pag.12
Italiano
IT
7.1-Cooling fans (optional)...................................................................................................................Pag.12
7.2-Heating unit (optional) ...................................................................................................................Pag.12
7.3-Mounting instructions for automatic purge with timer (optional)...................................................Pag.13
8-Safety instructions ........................................................................................................................................Pag.14
Italiano
IT
9-Maintenance.........................................................................................................................................Pag.14
9.1- Periodic maintenance....................................................................................................................Pag.14
9.2-Trouble shooting.............................................................................................................................Pag.14
IT
10-Phasing out and disposal...........................................................................................................................Pag.17
Italiano
9.3-Registro interventi..........................................................................................................................Pag.15
11-Declaration of conformity.............................................................................................................................Pag.17
Pag. 2 - Manual code: 119G914
119G9141 ver. 1.
1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users.
English
EN
3-Reference Standards.......................................................................................................................................Pag.3
“IMPORTANT INSTALLATION, SAFETY INSTRUCTIONS”
“CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY”
“THIS MANUAL IS ONLY FOR PROFESSIONAL OR QUALIFIED INSTALLERS”
1 Legend of symbols
This symbol tells you to read the section with particular care.
This symbol tells you that the sections concern safety issues.
EN
This symbol tells you what to say to the end-users.
English
2.1 Intended use
This product can be used only for purposes indicated in this manual
The use of this product for purposes other than those described above and installation executed in a manner other than as instructed in this technical manual are prohibited.
Urbaco has no responsibility for any improper use of the system
2.2 Limits to use
Do not allow children to play or loiter within the movement area of the bollard.
Keep transmitters and any other command device out the reach of children, to prevent operator from being activated by accident.
3 Reference Standards
This product complies with the following standards: see chapter 11 - Conformity declaration - pag. 17.
4 Descriptions
1500 W
100 mA
Protection rating
IP 44-54
Acoustic pression
69-70 Db
Weight
60 kg
Cabinet material
Laquered 15/10 sheet metal
Operating temperature
-10° +55°
Duty cycle
40%
Italiano
IT
Weight
Draw when idle
Italiano
230 V - 50/60Hz
IT
(Electric) power supply
IT
4.1 Technical centre - technical features
Italiano
119G9141 ver. 1.
1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users.
Pag. 3 - Manual code: 119G914
2 Intended use and limits to use
4.2 (Technical centre) Description: Components and dimensions
5
4
3
2
10
6
9
1
5
7
8
IT
1
Italiano
a
2
Control panel
3
Magnetic loops (optional)
4
Hot/Cold thermostats (optional)
5
Cooling fans (optional)
6
Heating unit (optional)
7
Automatic purge (optional with timer)
8
Floor mounting basement (optional)
9
Air joints for bollards (Ø 10)
10
Air circuit discharge
11
Pressure regulator (manometer)
c
Italiano
IT
Italiano
IT
b
Compressor group/unit
d
e
a
300
b
806
c
606
d
100
e
270
Pag. 4 - Manual code: 119G914
119G9141 ver. 1.
1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users.
English
EN
11
4.3 (Technical centre) Pneumatic performances
The following performances have been recorded with a 50 m long conduit of 10 mm diameter
Ø 270
Ø 320
h 600
8
7
6
h 800
6
5
4
EN
Ø 200
English
Max no.
of bollards
Max no. of manoeuvres per hour
No. of
bollards
Ø 200
Ø 270
Ø 320
h 600
h 800
h 600
h 800
h 600
h 800
1
100
70
100
70
100
70
2
45
35
45
35
45
35
3
30
24
30
24
30
24
4
24
18
24
18
24
18
5
18
14
18
14
18
6
16
12
16
7
14
8
12
16
14
Reliable values if T=25°C and compressor duty cycle of up to 40%
The no. of manoeuvres should be evenly distributed over time
The conduit length has influence on the max no. of manoeuvres per hour
For intensive use manoeuvres the use the aeration kit is required
h 800
h 600
h 800
h 600
h 800
1
35
50
35
50
35
50
2
80
104
80
104
80
104
Ø 270
Ø 320
3
120
150
120
150
120
150
4
150
190
150
190
150
190
5
190
260
190
260
190
6
225
280
225
7
250
8
300
IT
h 600
Ø 200
Italiano
No. of
bollards
Italiano
IT
Minimal interval between two subsequent manoeuvres (s)
225
IT
250
Italiano
119G9141 ver. 1.
1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users.
Pag. 5 - Manual code: 119G914
Max no. of Luxor bollards operated simultaneously by a single technical centre
5 Card
Trimmer for the automatic
closing time adjustment
ON
1 2 3 4
Fuses
5
ON
L1T L2T
24 15 0
1 2 3 4 5
English
EN
Buttons for radio
programming
Compressor
1 2 3 4
5
6.3
Connector for radio
cards
L
N
Table of fuses
Additional control boards for
managing up to 3 access ways
Fuse for accessories
5A
Fuse for main line
630 mA
Fuse for control board
1A
Fuse for compressor
6.3 A -T
DIP n° 1
ON
OFF
Automatic closing – enabled
Automatic closing - disabled
Only-opening enabled
Only-opening disabled
3” Pre-flashing enabled
Pre-flashing disabled
DIP n° 2
IT
DIP n° 3
DIP n° 4
Italiano
Programming (see table below)
DIP n° 5
Switch
Italiano
IT
Italiano
IT
N°4
Button
N°5
CH1
CH2
Led
After 5”
Option
ON
ON
ON
It enables the bistable solenoid valve
ON
ON
OFF
It enables the monostable solenoid valve
ON
ON
ON
It enables the acoustic signaller and the flashing of the red traffic light
ON
ON
OFF
It disables the acoustic signaller
ON
ON
ON
Green traffic light enabled
ON
ON
OFF
Yellow traffic light enabled
ON
ON
ON
“Presence” function is enabled (it is possible to retract the bollard only
when the loop detects the mass)
ON
ON
OFF
“Presence” function is disabled
Put the n°4 and n° 5 dip switch into ON position, then press the CH1 or CH2 buttons. The led starts flashing. After 5”, if the led is
still flashing, it means that the option is enabled; if it is not, then the option is disabled.
Pag. 6 - Manual code: 119G914
119G9141 ver. 1.
1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users.
ON
5.1 Summary table of 24 V accessories’ power demand, expressed in W
U200 control panel to control 1 access way
Bistable solenoid valve *
3
Duty cycle
6
Traffic light
Magnetic loop
Total power (W), if with
bistable solenoid valve
48
8
24
6
18
8
25
11
2.5
Flashing light
1
2
3
24
25
22
7.5
102.5
25
22
7.5
120.5
Total (W)
U200 control panel + U201 board to control 2 separated access ways
Bistable solenoid valve *
8
3
3
Duty cycle
6
Traffic light **
Magnetic loop
Total power (W), if with
bistable solenoid valve
48
8
24
6
18
8
25
11
2.5
Flashing light**
Total power (W), if
with monostable
solenoid valve
2
4
6
24
50
50
44
44
15
131
Total (W)
15
125
113
117
Duty cycle
3
25
11
2.5
Flashing light ***
Traffic light ***
Magnetic loop
Total (W)
*
Total power (W), if
with monostable
solenoid valve
6
Total power (W), if with
bistable solenoid valve
48
8
24
6
IT
Bistable solenoid valve *
8
3
Monostable solenoid valve
Max no. of
connectable
accessories and
bollards
18
8
3
6
9
Italiano
Type of accessory
Single
accessory
power (W)
IT
U200 control panel + two U201 boards to control 3 separated access ways
Italiano
Monostable solenoid valve
Max no. of
connectable
accessories and
bollards
24
75
22.5
163.5
75
66
22.5
154.5
22.5
145.5
66
22.5
136.5
The bistable solenoid valves are used in such systems, where the bollard should remain in the higher
position even when voltage is cut off
** If you use the flashing light you cannot use the traffic light
*** According to this configuration, the flashing lights or the traffic lights should be externally supplied.
IT
Type of accessory
Single
accessory
power (W)
Italiano
119G9141 ver. 1.
1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users.
Pag. 7 - Manual code: 119G914
8
3
Total power (W), if
with monostable
solenoid valve
EN
Monostable solenoid valve
Max no. of
connectable
accessories and
bollards
English
Type of accessory
Single
accessory
power (W)
5.2 Electrical connections
L
Compressor
N
Line voltage 230V - 50/60Hz
N
Magnetic sensor/photocells max power supply (see tab. in chap. 5.1)
N
L
N
L
N
Flashing light output voltage 24V 25W
Red traffic light and illuminated ring (see tab. in chap. 5.1)
Italiano
IT
L
Yellow traffic light (see tab. in chap. 5.1)
N
N
Solenoid valve for the upward movement max voltage 24V AC (see tab. in chap. 5.1)
Italiano
L
IT
Italiano
IT
L
Solenoid valve for the downward movement 24V AC (optional) or downward
command for the bistable valve
Pag. 8 - Manual code: 119G914
119G9141 ver. 1.
1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users.
English
EN
L
Compressor
L
N
Closing button
N.C. STOP button
N
Step by step
English
SMA N.C. contact
Compressor surveillance
Purge opening
1
Purge closing
2
Italiano
To discharge air from the system and consequently move down the bollards, you can open the tap nearby the pressure switch (we
recommend you to do it when the compressor is shut down, in order to avoid that it starts automatically to compensate the pressure fall).To put the system into operation again, close the air discharge as shown in fig. 2 (and turn on the compressor, if you had
shut it down).
IT
5.3 Release/discharge the system from/inside the centre
IT
N
Italiano
L
Endstop - closing
IT
N
Endstop - opening
Italiano
L
119G9141 ver. 1.
1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users.
Pag. 9 - Manual code: 119G914
EN
L
6 Technical centre installation
-Check that no conduits or other obstacles shall prevent from excavating and installating operations.
-Check the soil consistence and its loading capacity.
-On the power supply line provide an omnipolar disconnecting device with an opening distance between contacts equal to or
larger than 3 mm. We recommend you to use a 10 A omnipolar disconnecting device.
-Remove any obstacle that can prevent the bollard form a normal operating mode.
-The magnetic loops positioning has influence on the access correct functioning.
In fact, we recommend you to chose first the loops position, then the bollards one and then that for the technical centre.
-Position the technical centre in a way to protect it from accidental hurting.
-Provide for a conduit to pass connections through it.
-When necessary, you need to install optical and sound signalization to minimize dangerous situations.
-Air flexibles max length must not exceed 100 m
-Max distance of the cable connecting the feeder and the magnetic loop shall not exceed 50 m.
Max depth for
magnetic loops: 150 mm
EXIT
Bollards
SAFETY
LOOP
Pit
PRESENCE
AND
SAFETY
LOOP
Sheaths
Sheath
Min. distance between
conductors
Italiano
IT
Italiano
IT
Italiano
IT
LOOPS
IN EXIT
ENTRANCE
Table of connections
Air piping
Rilsan PA11 - DIN 74324 Ø 10x8
Electrical connections between technical
centre and bollards
FG7(O) R0.6/1kW 10x1.5
Links between SMA and loop
Min. 20 windings per meter Ø 1x1.5
Connection to the traffic light
FG7(O) R0.6/1kW 3x1.5
Control unit
Pag. 10 - Manual code: 119G914
119G9141 ver. 1.
1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users.
English
EN
6.1 Preliminary checks
6.2 Technical centre fastening with reinforcement (optional – COREH02-LUX code)
150
70
120
Provided with:
• M8 cage nuts – 4 pieces
• washers – 4 pieces D8x24
• securing screws –
4 pieces M8x16 UNI 5739
• securing screws for
inspection flange
EN
Conduits connecting area
Flange for inspection
on both sides
2
3- and finally, as shown in picture n°2, fasten the
technical centre to the reinforcement using the
supplied screws
Italiano
IT
Italiano
2- then anchor the
reinforcement to the
floor
IT
1- hook the M8 cage
nuts as shown in
picture n°1
IT
Check that the fastening point is resistant and
protected against hurting. The fastening should be
carried out with suitable screws, plugs, etc. (not
included), depending on
the surface typology.
1
Italiano
119G9141 ver. 1.
1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users.
Pag. 11 - Manual code: 119G914
60
4 square holes for the M8
locked nuts
English
Dimensions and holes spans
7 Connection of additional devices
7.1 Cooling fans (optional – COVF-LUX code)
1) Take off the grids that shall support the fans.
1
2) On the grids mount the motors (please check to put one for intake and
another in discharge), by using the supplied cables.
a
b
2
OUT
c
OUT
IN
IN
d
Connection
scheme
a
Upper cover
b
Dustproof filter
c
Carter for motor fastening
Electrical connections, including earthing
e
Fan
f
Sealing
7.2 Heating unit (optional – COKCHGT-LUX code)
2
Following the scheme in pict. n°1, connect this heating unit to the thermostat by
using the supplied cables. Then put both of them into the technical centre (see
pict. 2)
1
IT
Thermostat
Italiano
f
d
Italiano
IT
Italiano
IT
LN
e
Heating unit
Connecting
scheme
L
N
Pag. 12 - Manual code: 119G914
119G9141 ver. 1.
1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users.
English
EN
NOTE: face the electrical connections (d – see pict. n°2) toward the inside of
the technical centre. The connecting cables should not come into contact with
heated zones (i.e. heating unit, compressor head).
7.3 Assembly of the automatic drainage with timer (optional - COPURA-LUX code)
1
English
Unscrew and take off tap and joint as shown
in pict. 2.
If present, please take off the sound-absorbing plug, as
shown in the pict.1, otherwise go to the second step,
shown in pict. 2.
Connect the condensate release with the timer to the
previously connected . Use a seal, as shown in pict. 4.
6
IT
Italiano
5
IT
Italiano
Using a 7 mm hexagonal wrench, screw the
extension provided in the automatic drainage kit, as shown in pict. 3.
4
IT
3
Insert in the rapid joint a Ø 7 conduit to enable the
release outside of the centre (pict. 5).
To feed the automatic drainage with timer, link
the two phases to the terminal board and connect the earthing as shown in pict. 6.
Italiano
119G9141 ver. 1.
1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users.
Pag. 13 - Manual code: 119G914
EN
2
8 Safety instructions
Important safety instructions
9 Maintenance
9.1 Periodic maintenance
-Before performing any maintenance procedures, cut off the main power, to prevent possible accidents due to gate movement.
Check point
Check and maintenance
1°
2°
3°
4°
5°
6°
7°
8°
9°
10°
11°
12°
month month month month month month month month month month month month
1
Compressor functioning
2
Cleaning of the centre
x
x
3
Endstops
x
x
4
Solenoid valve
x
x
5
No Air leak
x
x
6
Cooling fans
x
x
x
x
7
Heating unit
x
x
8
Automatic drainage functioning
x
x
9
Metal detecting loops
x
x
Italiano
IT
Italiano
IT
Italiano
IT
9.2 Problems resolution
MALFUNCTIONS
POSSIBLE CAUSES
REMEDIES
The solenoid valve is sup- The air doesn’t come to the solenoid valve.
plied (check it by using a
voltmeter) but the bollards The flux regulator is closed
doesn’t move upwards.
Solenoid valve winding has burnt out
Check the compressor and the air circuit.
The bollard move upwards Presence of foreign bodies on the guide.
irregularly.
Air pressure is not sufficient.
Check the guides status. Pulire.
The compressor works too
frequently.
Air leak.
Check the flexible air tube and the couplings (if
needed use foam spray to detect leaks).
Air leak at the solenoid valve release.
Purge the circuit and clean (or replace) the
electrovalve (foreign objects in the air circuit).
The pressure is too high.
Check that pressure switch ( 6 – 8 bar when
working).
Open the flux regulator.
Change the winding.
Clean and verify the manometer regular pressure (6-8 bars)
Pag. 14 - Manual code: 119G914
119G9141 ver. 1.
1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users.
English
EN
This product must only be employed for its originally intended use. Any other use is wrong and potentially dangerous.
The manufacturer cannot be held liable for any damages resulting from wrongful, erroneous or negligent uses.
Avoid working close to the hinges or other moving mechanical parts. Stay out of the opening/closing arc when operator is in movement.
Do not exercise force against the motion of the operator as this could result in potentially dangerous situations.
Do not allow children to play or loiter within the opening/closing arc of the operator.
Keep transmitters and any other command device out the reach of children, to prevent operator from being activated by accident.
In the event of anomalous behaviour, stop using the operator immediately.
Provide for adequate safety systems such as magnetic loops, traffic lights or any device that shall prevent dangerous situations
1
Cover fastening
2
Slide ring
3
Endstop sensors
4
Solenoid valve
5
No air leak
6
Air discharge efficiency
7
Cover positioning
8
Illuminated ring
9
Magnetic loops
Installer stamp
YES
NO
Other actions
________________________________________
________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
EN
Check and maintenance
English
Check point
Date of intervention
Operator’s full name
Technician signature
Client signature
Check point
Check and maintenance
1
Cover fastening
2
Slide ring
3
Endstop sensors
4
Solenoid valve
5
No air leak
6
Air discharge efficiency
7
Cover positioning
8
Illuminated ring
9
Magnetic loops
Installer stamp
YES
NO
Other actions
________________________________________
________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
Date of intervention
Operator’s full name
IT
Technician signature
2
Slide ring
3
Endstop sensors
4
Solenoid valve
5
No air leak
6
Air discharge efficiency
7
Cover positioning
8
Illuminated ring
9
Magnetic loops
Installer stamp
YES
Date of intervention
Operator’s full name
Technician signature
Client signature
NO
Other actions
________________________________________
________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
IT
Cover fastening
Italiano
Check and maintenance
1
IT
Check point
Italiano
Client signature
Italiano
119G9141 ver. 1.
1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users.
Pag. 15 - Manual code: 119G914
9.3 Records of intervention
Check and maintenance
1
Cover fastening
2
Slide ring
3
Endstop sensors
4
Solenoid valve
5
No air leak
6
Air discharge efficiency
7
Cover positioning
8
Illuminated ring
9
Magnetic loops
Installer stamp
YES
NO
Other actions
________________________________________
________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
Date of intervention
Technician signature
Client signature
Check point
Check and maintenance
1
Cover fastening
2
Slide ring
3
Endstop sensors
4
Solenoid valve
5
No air leak
6
Air discharge efficiency
7
Cover positioning
8
Illuminated ring
9
Magnetic loops
Installer stamp
YES
NO
Other actions
________________________________________
________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
Date of intervention
Operator’s full name
Technician signature
Italiano
IT
Italiano
IT
Italiano
IT
Client signature
Check point
Check and maintenance
1
Cover fastening
2
Slide ring
3
Endstop sensors
4
Solenoid valve
5
No air leak
6
Air discharge efficiency
7
Cover positioning
8
Illuminated ring
9
Magnetic loops
Installer stamp
YES
Date of intervention
Operator’s full name
Technician signature
Client signature
NO
Other actions
________________________________________
________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
Pag. 16 - Manual code: 119G914
119G9141 ver. 1.
1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users.
Operator’s full name
English
EN
Check point
Check and maintenance
1
Cover fastening
2
Slide ring
3
Endstop sensors
4
Solenoid valve
5
No air leak
6
Air discharge efficiency
7
Cover positioning
8
Illuminated ring
9
Magnetic loops
Installer stamp
YES
NO
Other actions
________________________________________
________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
EN
Check point
Date of intervention
English
Technician signature
Client signature
10 Phasing out and disposal
Italiano
PRODUCT DISPOSAL
Our products are made of different types of materials. Most of these (i.e. aluminium, plastic, iron, electrical cables) are to be disposed
of as solid urban waste. These can be recycled through separate waste collection and disposal at authorised facilities.
Other components (i.e. electronic cards, remote control batteries, etc.) may contain hazardous materials. Thus, they must be treated
and hand over to special firms authorised to properly dispose of them.
Before acting, always check the specific, current legislation in your location.
DO NOT DISPOSE OF IN THE ENVIRONMENT !
IT
We kindly ask you to also safeguard the envirnoment, because we at URBACO considere it to be one of the fundamental
elements of development of its market and operational strategies. You can do this by simply following simple disposing
instructions :
DISPOSING OF THE PACKAGING
The components of the packaging (i.e. cardboard, plastic, etc.) are solid urban waste and can be disposed of without problems, just
throw them out in the proper, correspoding recycling bins.
The components of the packaging (i.e. cardboard, plastic, etc.) are solid urban waste and can be disposed of without problems, just
throw them out in the proper, correspoding recycling bins.
DO NOT DISPOSE OF IN THE ENVIRONMENT !
11 Declaration of conformity
IT
MANUFACTURER’S DECLARATION
Declares under its own responsibility that the equipments listed below:
LUXOR AUTOMATIC RETRACTABLE BOLLARDS
BPLUXE60/G/R, BPLUXE80/G/R, PLUXF60/G/R, BPLUXF80/G/R,
BPLUXG60/G/R, BPLUXG80/G/R,
LUXOR TECHNICAL CENTERS
CC6U200PR, CC6U200PRS,
LUXOR COMPLEMENTARY ACCESSORIES
COPURA-LUX, COKCHGT-LUX, BOEVP-LUX, BOEVB-LUX,
COVF-LUX, KITBEA-LUX,
--- DIRECTIVES --98/37/CE - 98/79/CE
2004/108/CE
2006/95/CE
87/404/CEE
97/37/CE
MACHINERY DIRECTIVE
ELECTROMAGNETIC C OMPATIBILITY DIRECTIVE
L OW VOLTAGE DIRECTIVE
SIMPLE PRESSURE VESSELS DIRECTIVE
PRESSURE EQUIPMENT DIRECTIVE
--- STANDARDS --EN 60204-1
EN 61000-6-2
EN 11201
EN 1050
EN 61000-6-3
EN 1012-1
EN 60529
NF P 98-310
EN 60068-2
EN 3744
IMPORTANT WARNING!
This statement is legally binding only if the speciļ¬cations in the supplied instruction
manual have been properly followed.
Do not use the equipment speciļ¬ ed here above, before completing the full installationIn
full compliance with the Machinery Directive 98/37/EC.
comply with the National Law related to the following European Directives and to the
applicable parts of the following Standards.
the Chairman
Andrea Menuzzo
IT
URBACO S.A.
Z.A. du Couquiou
84320 ENTRAIGUES
FRANCE
Italiano
Pursuant to annex II A of the Machinery Directive 98/37/EC
Italiano
119G9141 ver. 1.
1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users.
Pag. 17 - Manual code: 119G914
Operator’s full name
English - Manual code: 119G9141 ver. 1.2 04/2008 © URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO s.a. to notify users.
URBACO SA
ZA du Couquiou
84320 ENTRAIGUES -FRANCE
www.urbaco.com

advertisement

Key Features

  • Pneumatic control system
  • Optional accessories
  • Up to 3 access way control
  • Bollard operation and control
  • Public and private space application
  • Parking lot, loading docks and other areas control

Frequently Answers and Questions

How many access ways can the LUXOR CC6U200PR, LUXOR CC6U200PRS Technical Centre control?
The LUXOR CC6U200PR, LUXOR CC6U200PRS Technical Centre can control up to 3 access ways
What are some of the optional accessories that can be installed with the LUXOR CC6U200PR, LUXOR CC6U200PRS Technical Centre?
Some of the optional accessories that can be installed with the LUXOR CC6U200PR, LUXOR CC6U200PRS Technical Centre include cooling fans, a heating unit, and an automatic drainage system with timer
What kind of spaces can the LUXOR CC6U200PR, LUXOR CC6U200PRS Technical Centre be used in?
The LUXOR CC6U200PR, LUXOR CC6U200PRS Technical Centre can be used in public and private spaces
What are some of the applications of the LUXOR CC6U200PR, LUXOR CC6U200PRS Technical Centre?
The LUXOR CC6U200PR, LUXOR CC6U200PRS Technical Centre can be used to control access to parking lots, loading docks, and other areas.

Related manuals

Download PDF

advertisement